MG ZS OBD-II support
Model years 2017 to 2026CombustionOnboarded
Sold as the Astor in India.
515 miles driven with Pelican by 22 drivers
829 kilometers driven with Pelican by 22 drivers
The OBDb lists 144 parameters for the MG ZS across 10 control modules. Support is recorded for 52 of the parameters. Support is recorded for model years 2020, 2023.
Parameter test map
247Every parameter, A-Z. Select a square to see its details.
All years combines recorded results. Orange means supported in some years and not supported in others. Years still needing testers do not change the color. Select a year to see its results.
Where is the MG ZS's OBD-II port?
Under the dashboard in front of the driver, on either side of the steering column.
Support by model year
A solid mark means OBDb records support for the parameter. A light mark means it is defined but unconfirmed. Results extend to other years in the same generation.
| Year | Status | Fuel | Speed | Range | OdoOdometer | Tires |
|---|---|---|---|---|---|---|
| 2017 to 2026 | Onboarded | Estimated |
Supported Unconfirmed
Parameters
These are MG's own commands for the ZS, plus the SAE J1979 standard parameters with recorded support for it. Open a group to see how Pelican decodes each parameter and which model years support it.
Connectables35
Absolute load value, Absolute throttle position, Absolute throttle position B, Air flow rate from mass air flow sensor and 31 more18 of 35 parameters supportedTester needed for 1718/35Battery8
Control module voltage, HV battery coolant temperature, HV battery current, HV battery health and 4 more5 of 8 parameters supportedTester needed for 35/8Battery › EVCC4
Charging, Current, Max current, VoltageAll parameters supported4/4Battery › Internal3
HV battery bus voltage, HV battery internal resistance, HV battery raw charge1 of 3 parameters supportedTester needed for 21/3Battery › Modules › 024
HV battery module 02 max temperature, HV battery module 02 max voltage, HV battery module 02 min temperature, HV battery module 02 min voltageAll parameters supported4/4Battery › Modules › 034
HV battery module 03 max temperature, HV battery module 03 max voltage, HV battery module 03 min temperature, HV battery module 03 min voltageAll parameters supported4/4Battery › Modules › 044
HV battery module 04 max temperature, HV battery module 04 max voltage, HV battery module 04 min temperature, HV battery module 04 min voltageAll parameters supported4/4Battery › Modules › 054
HV battery module 05 max temperature, HV battery module 05 max voltage, HV battery module 05 min temperature, HV battery module 05 min voltageAll parameters supported4/4Battery › Modules › 064
HV battery module 06 max temperature, HV battery module 06 max voltage, HV battery module 06 min temperature, HV battery module 06 min voltageAll parameters supported4/4Battery › Modules › 074
HV battery module 07 max temperature, HV battery module 07 max voltage, HV battery module 07 min temperature, HV battery module 07 min voltageTester needed for 40/4Battery › Modules › 084
HV battery module 08 max temperature, HV battery module 08 max voltage, HV battery module 08 min temperature, HV battery module 08 min voltageTester needed for 40/4Battery › Modules › 094
HV battery module 09 max temperature, HV battery module 09 max voltage, HV battery module 09 min temperature, HV battery module 09 min voltageTester needed for 40/4Battery › Modules › 104
HV battery module 10 max temperature, HV battery module 10 max voltage, HV battery module 10 min temperature, HV battery module 10 min voltageTester needed for 40/4Battery › Modules › 114
HV battery module 11 max temperature, HV battery module 11 max voltage, HV battery module 11 min temperature, HV battery module 11 min voltageTester needed for 40/4Battery › Modules › 124
HV battery module 12 max temperature, HV battery module 12 max voltage, HV battery module 12 min temperature, HV battery module 12 min voltageTester needed for 40/4Battery › Modules › 134
HV battery module 13 max temperature, HV battery module 13 max voltage, HV battery module 13 min temperature, HV battery module 13 min voltageTester needed for 40/4Battery › Modules › 144
HV battery module 14 max temperature, HV battery module 14 max voltage, HV battery module 14 min temperature, HV battery module 14 min voltageTester needed for 40/4Battery › Modules › 154
HV battery module 15 max temperature, HV battery module 15 max voltage, HV battery module 15 min temperature, HV battery module 15 min voltageTester needed for 40/4Battery › Modules › 164
HV battery module 16 max temperature, HV battery module 16 max voltage, HV battery module 16 min temperature, HV battery module 16 min voltageTester needed for 40/4Battery › Modules › 174
HV battery module 17 max temperature, HV battery module 17 max voltage, HV battery module 17 min temperature, HV battery module 17 min voltageAll parameters supported4/4Battery › Modules › 184
HV battery module 18 max temperature, HV battery module 18 max voltage, HV battery module 18 min temperature, HV battery module 18 min voltageTester needed for 40/4Battery › Modules › 194
HV battery module 19 max temperature, HV battery module 19 max voltage, HV battery module 19 min temperature, HV battery module 19 min voltageAll parameters supported4/4Battery › Modules › 204
HV battery module 20 max temperature, HV battery module 20 max voltage, HV battery module 20 min temperature, HV battery module 20 min voltageAll parameters supported4/4Battery › Modules › 214
HV battery module 21 max temperature, HV battery module 21 max voltage, HV battery module 21 min temperature, HV battery module 21 min voltageTester needed for 40/4Battery › Modules › 224
HV battery module 22 max temperature, HV battery module 22 max voltage, HV battery module 22 min temperature, HV battery module 22 min voltageAll parameters supported4/4Battery › Modules › 234
HV battery module 23 max temperature, HV battery module 23 max voltage, HV battery module 23 min temperature, HV battery module 23 min voltageTester needed for 40/4Battery › Modules › 244
HV battery module 24 max temperature, HV battery module 24 max voltage, HV battery module 24 min temperature, HV battery module 24 min voltageAll parameters supported4/4Climate1
Ambient air temperatureSupported1/1Clocks1
Time since engine startSupported1/1Control3
Absolute throttle position, Absolute throttle position B, Relative throttle positionAll parameters supported3/3Control › Pedals3
Accelerator pedal position (relative), Accelerator pedal position D, Accelerator pedal position EAll parameters supported3/3DTCs6
Distance traveled since diagnostic trouble codes cleared, Distance traveled while MIL was activated, Engine run time since diagnostic trouble codes cleared, Malfunction indicator lamp and 2 moreAll parameters supported6/6DTCs › Status30
A/C system refrigerant monitoring, A/C system refrigerant monitoring completed, A/C system refrigerant monitoring ready, Catalyst monitoring and 26 moreAll parameters supported30/30DTCs › Support16
A/C system refrigerant monitoring supported, Catalyst monitoring supported, Comprehensive component monitoring enabled, Comprehensive component monitoring supported and 12 moreAll parameters supported16/16ECU1
Vehicle gateway statusSupported1/1Engine36
Absolute load value, Air flow rate from mass air flow sensor, Ambient temperature, raw count, Barometric pressure and 32 more20 of 36 parameters supportedTester needed for 1620/36Engine › Internal2
Is ECT sensor 1 supported?, Is ECT sensor 2 supported?All parameters supported2/2Engine › OxygenSensors14
02S Bank 1, Sensor 1 present, 02S Bank 1, Sensor 2 present, 02S Bank 1, Sensor 3 present, 02S Bank 1, Sensor 4 present and 10 moreAll parameters supported14/14Fuel4
Fuel system 1 status, Fuel system 2 status, Fuel tank level, Fuel tank levelAll parameters supported4/4Movement2
Blower speed, Vehicle speed1 of 2 parameters supportedTester needed for 11/2OBD1
OBD requirements to which vehicle is designedSupported1/1Tires16
Front left tire pressure, Front left tire pressure, Front left tire temperature, Front left tire temperature and 12 moreTester needed for 160/16Trips4
Odometer, Odometer, Odometer reading, raw count, Odometer, body control module2 of 4 parameters supportedTester needed for 22/4
CarPlay
Apple lists CarPlay for the MG ZS in model years 2017 to 2025.
CarPlay can change with the market and the trim level. Ask the dealer about a specific car.
Help onboard this car
Help onboard more cars to the OBDb by installing Pelican, connecting your OBD scanner and driving. Joining the beta testing crew gives you early access to upcoming Pelican features through limited-access TestFlight builds.