Parameters
The MG ZS has 144 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
HV battery coolant temperature ZS_HVBAT_COOLANT_TEMP
- Service 22
DID B05C - Module
7DF → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery current ZS_HVBAT_CURRENT
- Service 22
DID B043 - Module
7DF → 7ED - Every
250 ms - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 250 A
- Unit
- A
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery health ZS_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Service 22
DID B061 - Module
7DF → 7ED - Every
30 s - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery is charging? ZS_HVBAT_CHARGING
Pelican can show this parameter as the charging state.
- Service 22
DID B048 - Module
7DF → 7ED - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery temperature ZS_HVBAT_TEMP
- Service 22
DID B056 - Module
7DF → 7ED - Every
60 s - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery voltage ZS_HVBAT_VOLTAGE
- Service 22
DID B042 - Module
7DF → 7ED - Every
250 ms - Testing for 2017 to 2019, 2021 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 500 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2020, 2023. Not supported for 2022.
Knock sensor voltage ZS_KNOCK_SNS_V
- Service 22
DID B140 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2017 to 2026.
EVCC
Charging ZS_EVCC_CHARGING
- Service 22
DID B00F - Module
7DF → 7EC - Every
4 s - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
Current ZS_EVCC_CURRENT
- Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 250 A
- Unit
- A
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
Max current ZS_EVCC_MAX_CURRENT
- Service 22
DID B003 - Module
7DF → 7EC - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 110.8695 A
- Unit
- A
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
Voltage ZS_EVCC_VOLTAGE
- Service 22
DID B010 - Module
7DF → 7EC - Every
4 s - Testing for 2017 to 2019, 2021 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 675.6185 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2020, 2023. Not supported for 2022.
Internal
HV battery bus voltage ZS_HVBAT_BUS_VOLTAGE
- Service 22
DID B041 - Module
7DF → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery internal resistance ZS_HVBAT_RESISTANCE
- Service 22
DID B045 - Module
7DF → 7ED - Every
60 s - Testing for 2017 to 2019, 2021 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5
- Unit
- Number
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2020, 2023. Not supported for 2022.
HV battery raw charge ZS_HVBAT_RAW_SOC
HV battery raw charge
- Service 22
DID B046 - Module
7DF → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2019, 2021, 2024 to 2026. Not supported for 2020, 2022 to 2023.
Modules › 02
HV battery module 02 max temperature ZS_HVBAT_CMU02_MAXTEMP
- Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 02 max voltage ZS_HVBAT_CMU02_MAXVOLT
- Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 02 min temperature ZS_HVBAT_CMU02_MINTEMP
- Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 02 min voltage ZS_HVBAT_CMU02_MINVOLT
- Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
Modules › 03
HV battery module 03 max temperature ZS_HVBAT_CMU03_MAXTEMP
- Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2022, 2024 to 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2020, 2023. Not supported for 2022.
HV battery module 03 max voltage ZS_HVBAT_CMU03_MAXVOLT
- Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2022, 2024 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2020, 2023. Not supported for 2022.
HV battery module 03 min temperature ZS_HVBAT_CMU03_MINTEMP
- Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2022, 2024 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2020, 2023. Not supported for 2022.
HV battery module 03 min voltage ZS_HVBAT_CMU03_MINVOLT
- Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2020, 2023. Not supported for 2022.
Modules › 04
HV battery module 04 max temperature ZS_HVBAT_CMU04_MAXTEMP
- Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 04 max voltage ZS_HVBAT_CMU04_MAXVOLT
- Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 04 min temperature ZS_HVBAT_CMU04_MINTEMP
- Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 04 min voltage ZS_HVBAT_CMU04_MINVOLT
- Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
Modules › 05
HV battery module 05 max temperature ZS_HVBAT_CMU05_MAXTEMP
- Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 05 max voltage ZS_HVBAT_CMU05_MAXVOLT
- Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 05 min temperature ZS_HVBAT_CMU05_MINTEMP
- Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 05 min voltage ZS_HVBAT_CMU05_MINVOLT
- Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
Modules › 06
HV battery module 06 max temperature ZS_HVBAT_CMU06_MAXTEMP
- Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2023 to 2026. Supported for 2020. Not supported for 2021 to 2022.
HV battery module 06 max voltage ZS_HVBAT_CMU06_MAXVOLT
- Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2023 to 2026. Supported for 2020. Not supported for 2021 to 2022.
HV battery module 06 min temperature ZS_HVBAT_CMU06_MINTEMP
- Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2023 to 2026. Supported for 2020. Not supported for 2021 to 2022.
HV battery module 06 min voltage ZS_HVBAT_CMU06_MINVOLT
- Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2023 to 2026. Supported for 2020. Not supported for 2021 to 2022.
Modules › 07
HV battery module 07 max temperature ZS_HVBAT_CMU07_MAXTEMP
- Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 07 max voltage ZS_HVBAT_CMU07_MAXVOLT
- Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 07 min temperature ZS_HVBAT_CMU07_MINTEMP
- Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 07 min voltage ZS_HVBAT_CMU07_MINVOLT
- Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
Modules › 08
HV battery module 08 max temperature ZS_HVBAT_CMU08_MAXTEMP
- Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 08 max voltage ZS_HVBAT_CMU08_MAXVOLT
- Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 08 min temperature ZS_HVBAT_CMU08_MINTEMP
- Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 08 min voltage ZS_HVBAT_CMU08_MINVOLT
- Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
Modules › 09
HV battery module 09 max temperature ZS_HVBAT_CMU09_MAXTEMP
- Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 09 max voltage ZS_HVBAT_CMU09_MAXVOLT
- Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 09 min temperature ZS_HVBAT_CMU09_MINTEMP
- Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 09 min voltage ZS_HVBAT_CMU09_MINVOLT
- Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
Modules › 10
HV battery module 10 max temperature ZS_HVBAT_CMU10_MAXTEMP
- Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2023 to 2026. Not supported for 2020 to 2022.
HV battery module 10 max voltage ZS_HVBAT_CMU10_MAXVOLT
- Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2023 to 2026. Not supported for 2020 to 2022.
HV battery module 10 min temperature ZS_HVBAT_CMU10_MINTEMP
- Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2023 to 2026. Not supported for 2020 to 2022.
HV battery module 10 min voltage ZS_HVBAT_CMU10_MINVOLT
- Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2023 to 2026. Not supported for 2020 to 2022.
Modules › 11
HV battery module 11 max temperature ZS_HVBAT_CMU11_MAXTEMP
- Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 11 max voltage ZS_HVBAT_CMU11_MAXVOLT
- Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 11 min temperature ZS_HVBAT_CMU11_MINTEMP
- Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 11 min voltage ZS_HVBAT_CMU11_MINVOLT
- Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
Modules › 12
HV battery module 12 max temperature ZS_HVBAT_CMU12_MAXTEMP
- Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 12 max voltage ZS_HVBAT_CMU12_MAXVOLT
- Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 12 min temperature ZS_HVBAT_CMU12_MINTEMP
- Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 12 min voltage ZS_HVBAT_CMU12_MINVOLT
- Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
Modules › 13
HV battery module 13 max temperature ZS_HVBAT_CMU13_MAXTEMP
- Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 13 max voltage ZS_HVBAT_CMU13_MAXVOLT
- Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 13 min temperature ZS_HVBAT_CMU13_MINTEMP
- Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 13 min voltage ZS_HVBAT_CMU13_MINVOLT
- Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
Modules › 14
HV battery module 14 max temperature ZS_HVBAT_CMU14_MAXTEMP
- Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 14 max voltage ZS_HVBAT_CMU14_MAXVOLT
- Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 14 min temperature ZS_HVBAT_CMU14_MINTEMP
- Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 14 min voltage ZS_HVBAT_CMU14_MINVOLT
- Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
Modules › 15
HV battery module 15 max temperature ZS_HVBAT_CMU15_MAXTEMP
- Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 15 max voltage ZS_HVBAT_CMU15_MAXVOLT
- Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 15 min temperature ZS_HVBAT_CMU15_MINTEMP
- Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 15 min voltage ZS_HVBAT_CMU15_MINVOLT
- Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
Modules › 16
HV battery module 16 max temperature ZS_HVBAT_CMU16_MAXTEMP
- Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 16 max voltage ZS_HVBAT_CMU16_MAXVOLT
- Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 16 min temperature ZS_HVBAT_CMU16_MINTEMP
- Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 16 min voltage ZS_HVBAT_CMU16_MINVOLT
- Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
Modules › 17
HV battery module 17 max temperature ZS_HVBAT_CMU17_MAXTEMP
- Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2022, 2024 to 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2023. Not supported for 2020, 2022.
HV battery module 17 max voltage ZS_HVBAT_CMU17_MAXVOLT
- Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2022, 2024 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2023. Not supported for 2020, 2022.
HV battery module 17 min temperature ZS_HVBAT_CMU17_MINTEMP
- Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2022, 2024 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2023. Not supported for 2020, 2022.
HV battery module 17 min voltage ZS_HVBAT_CMU17_MINVOLT
- Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2023. Not supported for 2020, 2022.
Modules › 18
HV battery module 18 max temperature ZS_HVBAT_CMU18_MAXTEMP
- Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 18 max voltage ZS_HVBAT_CMU18_MAXVOLT
- Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 18 min temperature ZS_HVBAT_CMU18_MINTEMP
- Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 18 min voltage ZS_HVBAT_CMU18_MINVOLT
- Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
Modules › 19
HV battery module 19 max temperature ZS_HVBAT_CMU19_MAXTEMP
- Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 19 max voltage ZS_HVBAT_CMU19_MAXVOLT
- Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 19 min temperature ZS_HVBAT_CMU19_MINTEMP
- Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 19 min voltage ZS_HVBAT_CMU19_MINVOLT
- Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
Modules › 20
HV battery module 20 max temperature ZS_HVBAT_CMU20_MAXTEMP
- Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 20 max voltage ZS_HVBAT_CMU20_MAXVOLT
- Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 20 min temperature ZS_HVBAT_CMU20_MINTEMP
- Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
HV battery module 20 min voltage ZS_HVBAT_CMU20_MINVOLT
- Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Supported for 2020. Not supported for 2022.
Modules › 21
HV battery module 21 max temperature ZS_HVBAT_CMU21_MAXTEMP
- Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 21 max voltage ZS_HVBAT_CMU21_MAXVOLT
- Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 21 min temperature ZS_HVBAT_CMU21_MINTEMP
- Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 21 min voltage ZS_HVBAT_CMU21_MINVOLT
- Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
Modules › 22
HV battery module 22 max temperature ZS_HVBAT_CMU22_MAXTEMP
- Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2022, 2024 to 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2023. Not supported for 2020, 2022.
HV battery module 22 max voltage ZS_HVBAT_CMU22_MAXVOLT
- Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2022, 2024 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2023. Not supported for 2020, 2022.
HV battery module 22 min temperature ZS_HVBAT_CMU22_MINTEMP
- Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2022, 2024 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2023. Not supported for 2020, 2022.
HV battery module 22 min voltage ZS_HVBAT_CMU22_MINVOLT
- Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2023. Not supported for 2020, 2022.
Modules › 23
HV battery module 23 max temperature ZS_HVBAT_CMU23_MAXTEMP
- Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 23 max voltage ZS_HVBAT_CMU23_MAXVOLT
- Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 23 min temperature ZS_HVBAT_CMU23_MINTEMP
- Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
HV battery module 23 min voltage ZS_HVBAT_CMU23_MINVOLT
- Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2021, 2023 to 2026. Not supported for 2020, 2022.
Modules › 24
HV battery module 24 max temperature ZS_HVBAT_CMU24_MAXTEMP
- Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2023 to 2026. Supported for 2020. Not supported for 2021 to 2022.
HV battery module 24 max voltage ZS_HVBAT_CMU24_MAXVOLT
- Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2023 to 2026. Supported for 2020. Not supported for 2021 to 2022.
HV battery module 24 min temperature ZS_HVBAT_CMU24_MINTEMP
- Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2019, 2023 to 2026. Supported for 2020. Not supported for 2021 to 2022.
HV battery module 24 min voltage ZS_HVBAT_CMU24_MINVOLT
- Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing for 2017 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2017 to 2019, 2023 to 2026. Supported for 2020. Not supported for 2021 to 2022.
ECU
Vehicle gateway status ZS_GWM_STATUS
- Service 22
DID D001 - Module
710 → 718 - Every
4 s - Testing for 2017 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2023. Not supported for 2020, 2022.
Engine
Ambient temperature, raw count ZS_AAT_RAW_CNT
- Service 22
DID E01B - Module
750 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Battery main relay B ZS_MG_BMS
- Service 22
DID B049 - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Battery main relay G ZS_MG_BMS_SYSTEMMAINRELAYG
- Service 22
DID B04A - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Battery main relay P ZS_MG_BMS_SYSTEMMAINRELAYP
- Service 22
DID B052 - Module
781 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Cabin heater temperature ZS_PTC_T
- Service 22
DID E01C - Module
750 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2017 to 2026.
DC-DC converter low-voltage current ZS_DCDC_LV_CURRENT
- Service 22
DID B022 - Module
785 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 A
- Unit
- A
In testing for 2017 to 2026.
DC-DC converter power load ZS_DCDC_POWER_LOAD
- Service 22
DID B025 - Module
785 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 A
- Unit
- A
In testing for 2017 to 2026.
Engine oil pressure ZS_EOP
- Service 22
DID B036 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1500.7515 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Engine oil temperature ZS_EO_T
- Service 22
DID B034 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2017 to 2026.
FL face outlet temperature ZS_FL_FACE_OUTLET_T
- Service 22
DID E013 - Module
750 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2017 to 2026.
Misfires, cylinder 1 ZS_MISFIRES_C1
- Service 22
DID B143 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires, cylinder 2 ZS_MISFIRES_C2
- Service 22
DID B144 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires, cylinder 3 ZS_MISFIRES_C3
- Service 22
DID B145 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfires, cylinder 4 ZS_MISFIRES_C4
- Service 22
DID B146 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Transmission fluid temperature, ECU 10472701 and 11194479 ZS_ATF_T_ECU_10472701_11194479
- Service 22
DID B423 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Transmission fluid temperature, ECU 10513229 ZS_ATF_T_ECU_10513229
- Service 22
DID 1940 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Fuel
Fuel tank level ZS_FUEL_TANK_LEVELConfirmed
- Service 22
DID B043 - Module
7E0 → 7E8 - Every
1 s - Testing for 2017 to 2019, 2021 to 2026
Example reply from a 2020 MG ZS.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
0x0000 = 0 → = 0 L
Confirmed for 2020. In testing for 2017 to 2019, 2021 to 2026.
Movement
Blower speed ZS_BLOWER_SPD
- Service 22
DID E00F - Module
750 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Tires
Front left tire pressure ZS_BCM_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Front left tire pressure ZS_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID B001 - Module
724 → 72C - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Front left tire temperature ZS_BCM_TT_FL
Pelican can show this parameter as the front left tire temperature.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2017 to 2026.
Front left tire temperature ZS_TT_FL
Pelican can show this parameter as the front left tire temperature.
- Service 22
DID B003 - Module
724 → 72C - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2017 to 2026.
Front right tire pressure ZS_BCM_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Front right tire pressure ZS_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID B001 - Module
724 → 72C - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Front right tire temperature ZS_BCM_TT_FR
Pelican can show this parameter as the front right tire temperature.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2017 to 2026.
Front right tire temperature ZS_TT_FR
Pelican can show this parameter as the front right tire temperature.
- Service 22
DID B003 - Module
724 → 72C - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2017 to 2026.
Rear left tire pressure ZS_BCM_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Rear left tire pressure ZS_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID B001 - Module
724 → 72C - Every
15 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Rear left tire temperature ZS_BCM_TT_RL
Pelican can show this parameter as the rear left tire temperature.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2017 to 2026.
Rear left tire temperature ZS_TT_RL
Pelican can show this parameter as the rear left tire temperature.
- Service 22
DID B003 - Module
724 → 72C - Every
15 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2017 to 2026.
Rear right tire pressure ZS_BCM_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Rear right tire pressure ZS_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID B001 - Module
724 → 72C - Every
15 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Rear right tire temperature ZS_BCM_TT_RR
Pelican can show this parameter as the rear right tire temperature.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2017 to 2026.
Rear right tire temperature ZS_TT_RR
Pelican can show this parameter as the rear right tire temperature.
- Service 22
DID B003 - Module
724 → 72C - Every
15 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2017 to 2026.
Trips
Odometer ZS_GWM_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID B921 - Module
710 → 718 - Every
1 s - Testing for 2017 to 2019, 2021 to 2022, 2024 to 2026
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2019, 2021, 2024 to 2026. Supported for 2020, 2023. Not supported for 2022.
Odometer reading, raw count ZS_ODO_READING_RAW_CNT
- Service 22
DID B101 - Module
760 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215
- Unit
- Number
In testing for 2017 to 2026.
Odometer, body control module ZS_BCM_ODO
- Service 22
DID E101 - Module
740 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2026.