Parameters
The Volvo V90 Cross Country has 801 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery state of charge VOLVO_12V_BAT_ST_CHG
- Service 22
DID 4946 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4294 %
- Unit
- %
In testing for 2017 to 2025.
12V system voltage, hd VOLVO_EQA_AUX_V_HD
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 0201 - Module
624 → 5A4 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 V
- Unit
- V
In testing for 2017 to 2025.
All-wheel drive coupling module voltage VOLVO_MECU_V
- Service 22
DID DD02 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 63.75 V
- Unit
- V
In testing for 2017 to 2025.
Alternator charge voltage request VOLVO_ALTERNATOR_CHG_V_REQ
- Service 22
DID 411D - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Auxiliary battery current VOLVO_AUXILIARY_BAT
- Service 22
DID 4112 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -127 to 128 A
- Unit
- A
In testing for 2017 to 2025.
Auxiliary battery temperature VOLVO_AUXILIARY_BAT_T
- Service 22
DID 40D3 - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2017 to 2025.
Auxiliary battery voltage VOLVO_AUXILIARY_BAT_V
- Service 22
DID 417E - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Auxiliary battery voltage VOLVO_EQA_AUX_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 2005 - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.9 V
- Unit
- V
In testing for 2017 to 2025.
Average static low range battery current VOLVO_AVG_STATIC_LOW_RANGE
- Service 22
DID 4025 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -511 to 65024 mA
- Unit
- mA
In testing for 2017 to 2025.
Battery age condition VOLVO_ED_BAT_AGE
- Service 22
DID 6308 - Module
7E5 → 7ED - Every
600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 2017 to 2025.
Battery charge balance, ah VOLVO_BAT_CHG_BALANCE_AH
- Service 22
DID 41A5 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Battery charge, amps VOLVO_BAT_CHG_AMPS
- Service 22
DID 4090 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -511 to 3584 A
- Unit
- A
In testing for 2017 to 2025.
Battery current VOLVO_BAT_CURRENT
- Service 22
DID 4090 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 3583 A
- Unit
- A
In testing for 2017 to 2025.
Battery heater on VOLVO_ED_HEATER_ON
- Service 22
DID D302 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2025.
Battery module 1 temperature VOLVO_ED_MOD_T1
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
Battery module 2 temperature VOLVO_ED_MOD_T2
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
Battery module 3 temperature VOLVO_ED_MOD_T3
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
Battery module 4 temperature VOLVO_ED_MOD_T4
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
Battery module 5 temperature VOLVO_ED_MOD_T5
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
Battery module 6 temperature VOLVO_ED_MOD_T6
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
Battery module 7 temperature VOLVO_ED_MOD_T7
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
Battery module 8 temperature VOLVO_ED_MOD_T8
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
Battery module 9 temperature VOLVO_ED_MOD_T9
- Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
Battery operating mode VOLVO_EV_MODE
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 7
- Unit
- Number
In testing for 2017 to 2025.
Battery operation time since battery monitoring sensor reset, days VOLVO_BAT_OPERATION_TIME
- Service 22
DID 4027 - Module
726 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Battery relay VOLVO_BAT_RELAY
- Service 22
DID D953 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Battery state of charge VOLVO_BAT_ST_CHG
- Service 22
DID 4028 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2025.
Battery state of charge VOLVO_BAT_ST_CHG_726
- Service 22
DID 4028 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2025.
Battery temperature VOLVO_BAT_T
- Service 22
DID 4029 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
Battery voltage VOLVO_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 40CD - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1643 V
- Unit
- V
In testing for 2017 to 2025.
Battery voltage VOLVO_BAT_V_726
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 402A - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 18.75 V
- Unit
- V
In testing for 2017 to 2025.
Boost pressure after turbocharger VOLVO_BOOST_P_AFTER
- Service 22
DID 033E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -0.0534 to 500 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Capacity loss VOLVO_CAP_LOSS
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 2017 to 2025.
Cell capacity, average VOLVO_ED_CAP_AS_AVG
- Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
- Range
- 0 to 18.2041 Ah
- Unit
- Ah
In testing for 2017 to 2025.
Cell capacity, maximum VOLVO_ED_CAP_AS_MAX
- Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
- Range
- 0 to 18.2041 Ah
- Unit
- Ah
In testing for 2017 to 2025.
Cell capacity, minimum VOLVO_ED_CAP_AS_MIN
- Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
- Range
- 0 to 18.2041 Ah
- Unit
- Ah
In testing for 2017 to 2025.
Cell voltage reference, average VOLVO_ED_ADC_V_AVG
- Service 22
DID 0207 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2017 to 2025.
Cell voltage reference, maximum VOLVO_ED_ADC_V_MAX
- Service 22
DID 0207 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 1500 to 67035 mV
- Unit
- mV
In testing for 2017 to 2025.
Cell voltage reference, minimum VOLVO_ED_ADC_V_MIN
- Service 22
DID 0207 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 1500 to 67035 mV
- Unit
- mV
In testing for 2017 to 2025.
Charge air pressure VOLVO_CHG_AIR_P
- Service 22
DID EE3E - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Charge power limit VOLVO_CHG_POWER_LIM
- Service 22
DID 489C - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 4294 kW
- Unit
- kW
In testing for 2017 to 2025.
Charger 12V output voltage VOLVO_ED_OBL_LV
- Service 22
DID 0226 - Module
61A → 483 - Every
10 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Charger cable current VOLVO_CHARGER_CABLE
- Service 22
DID EE8D - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -410 to 6143 A
- Unit
- A
In testing for 2017 to 2025.
Charger cooling plate temperature VOLVO_ED_OBL_PLATE_T
- Service 22
DID 0223 - Module
61A → 483 - Every
60 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
Charger current set point VOLVO_ED_OBL_A_SET
- Service 22
DID 022A - Module
61A → 483 - Every
60 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 A
- Unit
- A
In testing for 2017 to 2025.
Charger HV output current VOLVO_ED_OBL_HV_A
- Service 22
DID 0225 - Module
61A → 483 - Every
10 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 204.7 A
- Unit
- A
In testing for 2017 to 2025.
Charger HV output voltage VOLVO_ED_OBL_HV
- Service 22
DID 0226 - Module
61A → 483 - Every
10 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 819 V
- Unit
- V
In testing for 2017 to 2025.
Charger mains current VOLVO_ED_OBL_MAINS_A
- Service 22
DID 0225 - Module
61A → 483 - Every
10 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 204.7 A
- Unit
- A
In testing for 2017 to 2025.
Charger mains current, phase 1 VOLVO_OBL_A1
- Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 5990.4 A
- Unit
- A
In testing for 2017 to 2025.
Charger mains current, phase 2 VOLVO_OBL_A2
- Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 5990.4 A
- Unit
- A
In testing for 2017 to 2025.
Charger mains voltage VOLVO_ED_OBL_MAINS_V
- Service 22
DID 0226 - Module
61A → 483 - Every
10 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 819 V
- Unit
- V
In testing for 2017 to 2025.
Charger mains voltage VOLVO_OBL_V
- Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5990.4 V
- Unit
- V
In testing for 2017 to 2025.
Charger power 1 VOLVO_OBL_P1
- Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.952 kW
- Unit
- kW
In testing for 2017 to 2025.
Charger power 2 VOLVO_OBL_P2
- Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.952 kW
- Unit
- kW
In testing for 2017 to 2025.
Charger temperature VOLVO_ED_OBL_T
- Service 22
DID 0223 - Module
61A → 483 - Every
60 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
Charging cable current code VOLVO_ED_OBL_CABLE_A
- Service 22
DID 0225 - Module
61A → 483 - Every
10 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2017 to 2025.
Charging plug detected VOLVO_PLUG
Pelican can show this parameter as the plug state.
- Service 22
DID 339D - Module
7E4 → 7EC - Every
5 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2025.
Charging socket lock VOLVO_CHG_SOCKET_LOCKED
- Service 22
DID EE8C - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | UNLOCKED | Unlocked |
2 | LOCKED | Locked |
In testing for 2017 to 2025.
Charging socket temperature VOLVO_ED_OBL_SOCKET_T
- Service 22
DID 0223 - Module
61A → 483 - Every
60 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
Control module supply voltage VOLVO_ENG_CTRL_MODULE_SUP_V
- Service 22
DID F442 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2017 to 2025.
Control module voltage VOLVO_CTRL_MODULE_V_MS_CAN
- Service 22
DID D904 - Module
784 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2025.
DC charger current VOLVO_DC_CHARGER_CURRENT
- Service 22
DID EE16 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 A
- Unit
- A
In testing for 2017 to 2025.
DC charger voltage VOLVO_DC_CHARGER_V
- Service 22
DID EE17 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 V
- Unit
- V
In testing for 2017 to 2025.
DC converter requested voltage VOLVO_EQA_CNVRTR_REQ_V
- Service 22
DID 6071 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 V
- Unit
- V
In testing for 2017 to 2025.
Discharge power limit VOLVO_DCHG_POWER_LIM
- Service 22
DID 489E - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 4294 kW
- Unit
- kW
In testing for 2017 to 2025.
Estimated capacity VOLVO_CAP_EST
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 182.0416 Ah
- Unit
- Ah
In testing for 2017 to 2025.
External temperature sensor, HV battery cooling module VOLVO_EXTERNAL_T_SENS
- Service 22
DID EE46 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2025.
Front camera voltage supply VOLVO_FRONT_CAMERA_V_SUP
- Service 22
DID 9969 - Module
764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20.4 V
- Unit
- V
In testing for 2017 to 2025.
Fuse DC charging voltage VOLVO_FUSE_DC_CHG_V
- Service 22
DID 498B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 V
- Unit
- V
In testing for 2017 to 2025.
High voltage battery - voltage at IEM fuse VOLVO_HVBAT_V_IEM_FUSE
- Service 22
DID 4859 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 V
- Unit
- V
In testing for 2017 to 2025.
High voltage battery - voltage at IHFA fuse VOLVO_HVBAT_V_IHFA_FUSE
- Service 22
DID 4858 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 V
- Unit
- V
In testing for 2017 to 2025.
High voltage battery cell voltage sum VOLVO_HVBAT_CELL_VOLTAGES
- Service 22
DID 497C - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2025.
High voltage battery contactor voltage VOLVO_HVBAT_CONTACTOR_V
- Service 22
DID 4857 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 V
- Unit
- V
In testing for 2017 to 2025.
High voltage battery coolant inlet temperature VOLVO_HVBAT_CLT_INLET_T
- Service 22
DID 4804 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2017 to 2025.
High voltage battery coolant outlet temperature VOLVO_HVBAT_CLT_OUTLET_T
- Service 22
DID 4990 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2017 to 2025.
High voltage battery current VOLVO_HVBAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Service 22
DID 4802 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 A
- Unit
- A
In testing for 2017 to 2025.
High voltage battery negative contactor voltage VOLVO_HVBAT_NEGATIVE_V
- Service 22
DID 4A58 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 V
- Unit
- V
In testing for 2017 to 2025.
High voltage battery state of charge VOLVO_HVBAT_ST_CHG
Pelican can show this parameter as the state of charge.
- Service 22
DID 4801 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131 %
- Unit
- %
In testing for 2017 to 2025.
High voltage battery state of health VOLVO_HVBAT_ST_HEALTH
Pelican can show this parameter as the state of health.
- Service 22
DID 496D - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 42949672 %
- Unit
- %
In testing for 2017 to 2025.
High voltage battery voltage VOLVO_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 4803 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2025.
High voltage battery, average temperature VOLVO_HVBAT_AVG_T
- Service 22
DID 491B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2017 to 2025.
High voltage battery, coolant pump speed, actual VOLVO_HVBAT_CLT_PMP_SPD_ACT
- Service 22
DID 4867 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2017 to 2025.
High voltage battery, coolant pump speed, requested VOLVO_HVBAT_CLT_PMP_SPD
- Service 22
DID 4866 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2017 to 2025.
High voltage battery, high-voltage coolant heater fuse voltage VOLVO_HVBAT_HVCH_FUSE_V
- Service 22
DID 480A - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2025.
High voltage battery, IEM fuse voltage VOLVO_HVBAT_IEM_FUSE_V
- Service 22
DID 4808 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2025.
High voltage battery, IGM fuse voltage VOLVO_HVBAT_IGM_FUSE_V
- Service 22
DID 4809 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2025.
High voltage battery, inlet coolant temperature VOLVO_HVBAT_INLET_ECT
- Service 22
DID 4804 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2017 to 2025.
High voltage battery, max temperature VOLVO_HVBAT_MAX_T
- Service 22
DID 4945 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2017 to 2025.
High voltage battery, OBC fuse voltage VOLVO_HVBAT_OBC_FUSE_V
- Service 22
DID 480B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2025.
High voltage system voltage VOLVO_HIGH_V_SYSTEM_V
- Service 22
DID 985C - Module
D016 → 1EC6EE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 V
- Unit
- V
In testing for 2017 to 2025.
High voltage system voltage VOLVO_HIGH_V_SYSTEM_V_D016
- Service 22
DID 985C - Module
D016 → 1ED24E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 V
- Unit
- V
In testing for 2017 to 2025.
Highest cell voltage VOLVO_CELL_V_MAX
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
HV battery amperage VOLVO_EQA_HV_A
- Service 22
DID 6053 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 A
- Unit
- A
In testing for 2017 to 2025.
HV battery available energy VOLVO_HV_E
- Service 22
DID 320C - Module
7E4 → 7EC - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 327.675 kWh
- Unit
- kWh
In testing for 2017 to 2025.
HV battery coolant temperature VOLVO_EQA_HV_COOLANT_T
- Service 22
DID 2526 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 °C
- Unit
- °C
In testing for 2017 to 2025.
HV battery current VOLVO_ED_HV_A
- Service 22
DID 0203 - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1024 to 1023.9687 A
- Unit
- A
In testing for 2017 to 2025.
HV battery current VOLVO_HV_A
Pelican can show this parameter as the traction battery current.
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1023.9687 to 1024 A
- Unit
- A
In testing for 2017 to 2025.
HV battery open-circuit voltage VOLVO_OCV
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2017 to 2025.
HV battery state of charge VOLVO_EQA_HV_SOC
Pelican can show this parameter as the state of charge.
- Service 22
DID 6050 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2025.
HV battery temperature VOLVO_ED_HV_T
- Service 22
DID 0201 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
HV battery temperature, average VOLVO_HV_T_AVG
- Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
HV battery temperature, maximum VOLVO_HV_T_MAX
- Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
HV battery temperature, minimum VOLVO_HV_T_MIN
- Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2017 to 2025.
HV battery voltage VOLVO_ED_HV_V
- Service 22
DID 0204 - Module
7E7 → 7EF - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 2017 to 2025.
HV battery voltage VOLVO_EQA_HV_V
- Service 22
DID 6075 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 V
- Unit
- V
In testing for 2017 to 2025.
HV battery voltage VOLVO_HV_V
Pelican can show this parameter as the traction battery voltage.
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 2017 to 2025.
HV contactor cycles remaining VOLVO_ED_CONT_LEFT
- Service 22
DID 030B - Module
7E7 → 7EF - Every
600 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215
- Unit
- Number
In testing for 2017 to 2025.
HV contactor cycles remaining VOLVO_HV_CONT_LEFT
- Service 21
PID 02 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2017 to 2025.
HV contactor cycles, maximum VOLVO_ED_CONT_MAX
- Service 22
DID 030C - Module
7E7 → 7EF - Every
600 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215
- Unit
- Number
In testing for 2017 to 2025.
HV contactor cycles, maximum VOLVO_HV_CONT_MAX
- Service 21
PID 02 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2017 to 2025.
HV contactor state VOLVO_ED_CONTACTOR
- Service 22
DID D000 - Module
7E7 → 7EF - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
HV contactor state VOLVO_HV_CONTACTOR
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 3
- Unit
- Number
In testing for 2017 to 2025.
HV DC fault code VOLVO_ED_DC_FAULT
- Service 22
DID 0209 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
HV isolation resistance VOLVO_ED_ISO
- Service 22
DID 0209 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65534 kΩ
- Unit
- kΩ
In testing for 2017 to 2025.
HV link voltage VOLVO_HV_LINK_V
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 2017 to 2025.
HV plug interlock closed VOLVO_HV_INTERLOCK_PLUG
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2025.
Initial capacity VOLVO_CAP_INIT
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 182.0416 Ah
- Unit
- Ah
In testing for 2017 to 2025.
Leakage current, 10 kilohertz VOLVO_LEAK_HF10
- Service 22
DID 5066 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 2017 to 2025.
Leakage DC current VOLVO_LEAK_DC
- Service 22
DID 5065 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 2017 to 2025.
Leakage diagnostic code VOLVO_LEAK_DIAG
- Service 22
DID 5064 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Leakage high-frequency current VOLVO_LEAK_HF
- Service 22
DID 5067 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 2017 to 2025.
Leakage low-frequency current VOLVO_LEAK_LF
- Service 22
DID 5068 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 2017 to 2025.
Lowest cell voltage VOLVO_CELL_V_MIN
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Main charger current VOLVO_MAIN_CHARGER_CURRENT
- Service 22
DID EE15 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 A
- Unit
- A
In testing for 2017 to 2025.
Main charger voltage VOLVO_MAIN_CHARGER_V
- Service 22
DID EE1C - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2017 to 2025.
Mains active power VOLVO_MAINS_P
- Service 22
DID 504A - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -20 to 45.5349 kW
- Unit
- kW
In testing for 2017 to 2025.
Mains current limit VOLVO_MAINS_A_LIMIT
- Service 22
DID 5070 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 2017 to 2025.
Mains current, phase 2 VOLVO_MAINS_A_2
- Service 22
DID 503A - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -200 to 3895.9375 A
- Unit
- A
In testing for 2017 to 2025.
Mains current, phase 3 VOLVO_MAINS_A_3
- Service 22
DID 503B - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -200 to 3895.9375 A
- Unit
- A
In testing for 2017 to 2025.
Mains frequency VOLVO_MAINS_HZ
- Service 22
DID 5049 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 10 to 521.9921 Hz
- Unit
- Hz
In testing for 2017 to 2025.
Mains ground resistance VOLVO_MAINS_GND_R
- Service 22
DID 5062 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 2017 to 2025.
Mains voltage, phases 1-2 VOLVO_MAINS_V_12
- Service 22
DID 503F - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 2017 to 2025.
Mains voltage, phases 2-3 VOLVO_MAINS_V_23
- Service 22
DID 5041 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 2017 to 2025.
Mains voltage, phases 3-1 VOLVO_MAINS_V_31
- Service 22
DID 5042 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 2017 to 2025.
Module voltage VOLVO_MODULE_V
- Service 22
DID D111 - Module
D016 → 1EC70E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Open-circuit voltage state VOLVO_OCV_STATE
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 4
- Unit
- Number
In testing for 2017 to 2025.
Real state of charge, maximum VOLVO_SOC_REAL_MAX
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 2017 to 2025.
Real state of charge, minimum VOLVO_SOC_REAL_MIN
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 2017 to 2025.
Secondary battery charge time VOLVO_SECONDARY_BAT_CHG
- Service 22
DID EED3 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2017 to 2025.
Secondary battery needed charge time VOLVO_SECONDARY_BAT_NEEDED
- Service 22
DID EED5 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2017 to 2025.
Secondary battery relay VOLVO_SECONDARY_BAT_RELAY
- Service 22
DID 419C - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Secondary battery temperature VOLVO_SECONDARY_BAT_T_25_C
- Service 22
DID EED2 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
Secondary battery voltage VOLVO_SECONDARY_BAT_V
- Service 22
DID 417E - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Secondary battery voltage average value VOLVO_SECONDARY_BAT_V_AVG
- Service 22
DID EED7 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Secondary battery voltage latest stored VOLVO_SECONDARY_BAT_V_LATEST
- Service 22
DID EED4 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Service interlock closed VOLVO_HV_INTERLOCK_SVC
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2025.
Servo supply voltage VOLVO_SERVO_SUP_V
- Service 22
DID 413D - Module
730 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Start/stop battery relay VOLVO_START_STOP_BAT_RELAY
- Service 22
DID EF51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Start/stop secondary battery relay VOLVO_START_STOP_SECONDARY
- Service 22
DID EF52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
State of charge VOLVO_SOC
- Service 22
DID 4028 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017, 2019, 2021 to 2025. Not supported for 2018, 2020.
State of charge VOLVO_SOC_V2
Pelican can show this parameter as the state of charge.
- Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 2017 to 2025.
State of charge recalibration state VOLVO_SOC_RECAL
- Service 21
PID 25 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 3
- Unit
- Number
In testing for 2017 to 2025.
State of charge, displayed VOLVO_SOC_DISPLAY
- Service 21
PID 25 - Module
79B → 7BB - Every
60 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 2017 to 2025.
State of health VOLVO_SOH
Pelican can show this parameter as the state of health.
- Service 21
PID 61 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 2017 to 2025.
State of health, raw VOLVO_ED_SOH
- Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Sum of cell voltages VOLVO_HV_CELL_SUM_V
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 2017 to 2025.
Supercharger clutch, requested position VOLVO_SUPERCHARGER_CLU_REQ
- Service 22
DID EE84 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Time with HV off VOLVO_ED_HV_OFF_TIME
- Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 s
- Unit
- s
In testing for 2017 to 2025.
Transmission control module supply voltage VOLVO_MECU_SUP_V
- Service 22
DID DD02 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 63.75 V
- Unit
- V
In testing for 2017 to 2025.
Usable capacity, full VOLVO_CAP_FULL
- Service 21
PID 61 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -91.0222 to 91.0194 Ah
- Unit
- Ah
In testing for 2017 to 2025.
Voltage supply VOLVO_V_SUP
- Service 22
DID D901 - Module
737 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20.4 V
- Unit
- V
In testing for 2017 to 2025.
Voltage supply VOLVO_V_SUP_764
- Service 22
DID D112 - Module
764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20.4 V
- Unit
- V
In testing for 2017 to 2025.
Voltage supply VOLVO_V_SUP_MS_CAN
- Service 22
DID D111 - Module
791 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Voltage/power sensitive loads connected VOLVO_V_POWER_SENSITIVE
- Service 22
DID EEA2 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Cells
Cell 1 voltage VOLVO_CELL_V1
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 1 voltage VOLVO_ED_CELL_V1
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 2 voltage VOLVO_CELL_V2
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 2 voltage VOLVO_ED_CELL_V2
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 3 voltage VOLVO_CELL_V3
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 3 voltage VOLVO_ED_CELL_V3
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 4 voltage VOLVO_CELL_V4
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 4 voltage VOLVO_ED_CELL_V4
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 5 voltage VOLVO_CELL_V5
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 5 voltage VOLVO_ED_CELL_V5
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 6 voltage VOLVO_CELL_V6
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 6 voltage VOLVO_ED_CELL_V6
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 7 voltage VOLVO_CELL_V7
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 7 voltage VOLVO_ED_CELL_V7
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 8 voltage VOLVO_CELL_V8
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 8 voltage VOLVO_ED_CELL_V8
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 9 voltage VOLVO_CELL_V9
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 9 voltage VOLVO_ED_CELL_V9
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 10 voltage VOLVO_CELL_V10
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 10 voltage VOLVO_ED_CELL_V10
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 11 voltage VOLVO_CELL_V11
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 11 voltage VOLVO_ED_CELL_V11
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 12 voltage VOLVO_CELL_V12
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 12 voltage VOLVO_ED_CELL_V12
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 13 voltage VOLVO_CELL_V13
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 13 voltage VOLVO_ED_CELL_V13
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 14 voltage VOLVO_CELL_V14
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 14 voltage VOLVO_ED_CELL_V14
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 15 voltage VOLVO_CELL_V15
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 15 voltage VOLVO_ED_CELL_V15
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 16 voltage VOLVO_CELL_V16
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 16 voltage VOLVO_ED_CELL_V16
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 17 voltage VOLVO_CELL_V17
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 17 voltage VOLVO_ED_CELL_V17
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 18 voltage VOLVO_CELL_V18
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 18 voltage VOLVO_ED_CELL_V18
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 19 voltage VOLVO_CELL_V19
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 19 voltage VOLVO_ED_CELL_V19
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 20 voltage VOLVO_CELL_V20
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 20 voltage VOLVO_ED_CELL_V20
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 21 voltage VOLVO_CELL_V21
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 21 voltage VOLVO_ED_CELL_V21
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 22 voltage VOLVO_CELL_V22
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 22 voltage VOLVO_ED_CELL_V22
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 23 voltage VOLVO_CELL_V23
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 23 voltage VOLVO_ED_CELL_V23
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 24 voltage VOLVO_CELL_V24
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 24 voltage VOLVO_ED_CELL_V24
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 25 voltage VOLVO_CELL_V25
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 25 voltage VOLVO_ED_CELL_V25
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 26 voltage VOLVO_CELL_V26
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 26 voltage VOLVO_ED_CELL_V26
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 27 voltage VOLVO_CELL_V27
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 27 voltage VOLVO_ED_CELL_V27
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 28 voltage VOLVO_CELL_V28
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 28 voltage VOLVO_ED_CELL_V28
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 29 voltage VOLVO_CELL_V29
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 29 voltage VOLVO_ED_CELL_V29
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 30 voltage VOLVO_CELL_V30
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 30 voltage VOLVO_ED_CELL_V30
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 31 voltage VOLVO_CELL_V31
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 31 voltage VOLVO_ED_CELL_V31
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 32 voltage VOLVO_CELL_V32
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 32 voltage VOLVO_ED_CELL_V32
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 33 voltage VOLVO_CELL_V33
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 33 voltage VOLVO_ED_CELL_V33
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 34 voltage VOLVO_CELL_V34
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 34 voltage VOLVO_ED_CELL_V34
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 35 voltage VOLVO_CELL_V35
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 35 voltage VOLVO_ED_CELL_V35
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 36 voltage VOLVO_CELL_V36
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 36 voltage VOLVO_ED_CELL_V36
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 37 voltage VOLVO_CELL_V37
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 37 voltage VOLVO_ED_CELL_V37
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 38 voltage VOLVO_CELL_V38
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 38 voltage VOLVO_ED_CELL_V38
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 39 voltage VOLVO_CELL_V39
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 39 voltage VOLVO_ED_CELL_V39
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 40 voltage VOLVO_CELL_V40
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 40 voltage VOLVO_ED_CELL_V40
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 41 voltage VOLVO_CELL_V41
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 41 voltage VOLVO_ED_CELL_V41
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 42 voltage VOLVO_CELL_V42
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 42 voltage VOLVO_ED_CELL_V42
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 43 voltage VOLVO_CELL_V43
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 43 voltage VOLVO_ED_CELL_V43
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 44 voltage VOLVO_CELL_V44
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 44 voltage VOLVO_ED_CELL_V44
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 45 voltage VOLVO_CELL_V45
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 45 voltage VOLVO_ED_CELL_V45
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 46 voltage VOLVO_CELL_V46
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 46 voltage VOLVO_ED_CELL_V46
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 47 voltage VOLVO_CELL_V47
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 47 voltage VOLVO_ED_CELL_V47
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 48 voltage VOLVO_CELL_V48
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 48 voltage VOLVO_ED_CELL_V48
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 49 voltage VOLVO_CELL_V49
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 49 voltage VOLVO_ED_CELL_V49
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 50 voltage VOLVO_CELL_V50
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 50 voltage VOLVO_ED_CELL_V50
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 51 voltage VOLVO_CELL_V51
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 51 voltage VOLVO_ED_CELL_V51
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 52 voltage VOLVO_CELL_V52
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 52 voltage VOLVO_ED_CELL_V52
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 53 voltage VOLVO_CELL_V53
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 53 voltage VOLVO_ED_CELL_V53
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 54 voltage VOLVO_CELL_V54
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 54 voltage VOLVO_ED_CELL_V54
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 55 voltage VOLVO_CELL_V55
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 55 voltage VOLVO_ED_CELL_V55
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 56 voltage VOLVO_CELL_V56
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 56 voltage VOLVO_ED_CELL_V56
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 57 voltage VOLVO_CELL_V57
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 57 voltage VOLVO_ED_CELL_V57
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 58 voltage VOLVO_CELL_V58
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 58 voltage VOLVO_ED_CELL_V58
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 59 voltage VOLVO_CELL_V59
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 59 voltage VOLVO_ED_CELL_V59
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 60 voltage VOLVO_CELL_V60
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 60 voltage VOLVO_ED_CELL_V60
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 61 voltage VOLVO_CELL_V61
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 61 voltage VOLVO_ED_CELL_V61
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 62 voltage VOLVO_CELL_V62
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 62 voltage VOLVO_ED_CELL_V62
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 63 voltage VOLVO_CELL_V63
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 63 voltage VOLVO_ED_CELL_V63
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 64 voltage VOLVO_CELL_V64
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 64 voltage VOLVO_ED_CELL_V64
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 65 voltage VOLVO_CELL_V65
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 65 voltage VOLVO_ED_CELL_V65
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 66 voltage VOLVO_CELL_V66
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 66 voltage VOLVO_ED_CELL_V66
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 67 voltage VOLVO_CELL_V67
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 67 voltage VOLVO_ED_CELL_V67
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 68 voltage VOLVO_CELL_V68
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 68 voltage VOLVO_ED_CELL_V68
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 69 voltage VOLVO_CELL_V69
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 69 voltage VOLVO_ED_CELL_V69
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 70 voltage VOLVO_CELL_V70
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 70 voltage VOLVO_ED_CELL_V70
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 71 voltage VOLVO_CELL_V71
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 71 voltage VOLVO_ED_CELL_V71
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 72 voltage VOLVO_CELL_V72
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 72 voltage VOLVO_ED_CELL_V72
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 73 voltage VOLVO_CELL_V73
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 73 voltage VOLVO_ED_CELL_V73
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 74 voltage VOLVO_CELL_V74
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 74 voltage VOLVO_ED_CELL_V74
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 75 voltage VOLVO_CELL_V75
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 75 voltage VOLVO_ED_CELL_V75
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 76 voltage VOLVO_CELL_V76
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 76 voltage VOLVO_ED_CELL_V76
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 77 voltage VOLVO_CELL_V77
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 77 voltage VOLVO_ED_CELL_V77
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 78 voltage VOLVO_CELL_V78
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 78 voltage VOLVO_ED_CELL_V78
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 79 voltage VOLVO_CELL_V79
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 79 voltage VOLVO_ED_CELL_V79
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 80 voltage VOLVO_CELL_V80
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 80 voltage VOLVO_ED_CELL_V80
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 81 voltage VOLVO_CELL_V81
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 81 voltage VOLVO_ED_CELL_V81
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 82 voltage VOLVO_CELL_V82
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 82 voltage VOLVO_ED_CELL_V82
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 83 voltage VOLVO_CELL_V83
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 83 voltage VOLVO_ED_CELL_V83
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 84 voltage VOLVO_CELL_V84
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 84 voltage VOLVO_ED_CELL_V84
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 85 voltage VOLVO_CELL_V85
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 85 voltage VOLVO_ED_CELL_V85
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 86 voltage VOLVO_CELL_V86
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 86 voltage VOLVO_ED_CELL_V86
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 87 voltage VOLVO_CELL_V87
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 87 voltage VOLVO_ED_CELL_V87
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 88 voltage VOLVO_CELL_V88
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 88 voltage VOLVO_ED_CELL_V88
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 89 voltage VOLVO_CELL_V89
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 89 voltage VOLVO_ED_CELL_V89
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 90 voltage VOLVO_CELL_V90
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 90 voltage VOLVO_ED_CELL_V90
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 91 voltage VOLVO_CELL_V91
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 91 voltage VOLVO_ED_CELL_V91
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 92 voltage VOLVO_CELL_V92
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 92 voltage VOLVO_ED_CELL_V92
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 93 voltage VOLVO_CELL_V93
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 93 voltage VOLVO_ED_CELL_V93
- Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2017 to 2025.
Cell 94 voltage VOLVO_CELL_V94
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 95 voltage VOLVO_CELL_V95
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Cell 96 voltage VOLVO_CELL_V96
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2017 to 2025.
Brakes
Vacuum pump pressure 1 VOLVO_ED_VAC_P1
- Service 22
DID 2041 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2017 to 2025.
Vacuum pump pressure 2 VOLVO_ED_VAC_P2
- Service 22
DID 2043 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2017 to 2025.
Climate
Auxiliary water pump duty cycle VOLVO_AUXILIARY_WATER_PMP
- Service 22
DID 4336 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2025.
Cabin blower command VOLVO_BLOWER
- Service 22
DID 34CB - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2025.
Evaporator temperature VOLVO_EVAPORATOR_T
- Service 22
DID 984F - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2017 to 2025.
Evaporator temperature v.2 VOLVO_EVAPORATOR_T_V_2
- Service 22
DID 9820 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -409 to 406 °C
- Unit
- °C
In testing for 2017 to 2025.
Fuel-operated heater, inlet water temperature VOLVO_FOH_INLET_WATER_T
- Service 22
DID 43BE - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
Fuel-operated heater, outlet water temperature VOLVO_FOH_OUTLET_WATER_T
- Service 22
DID 43BE - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
Heat exchanger temperature VOLVO_HEAT_EXCHANGER_T
- Service 22
DID 9850 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2017 to 2025.
Heat exchanger temperature v.2 VOLVO_HEAT_EXCHANGER_T_V_2
- Service 22
DID 4337 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -409 to 406 °C
- Unit
- °C
In testing for 2017 to 2025.
High-voltage coolant heater coolant inlet temperature VOLVO_HVCH_CLT_INLET_T
- Service 22
DID 4344 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
High-voltage coolant heater coolant outlet temperature VOLVO_HVCH_CLT_OUTLET_T
- Service 22
DID 4344 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
High-voltage coolant heater current consumption VOLVO_HVCH_CURRENT_CONS
- Service 22
DID 4345 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 63.75 A
- Unit
- A
In testing for 2017 to 2025.
High-voltage coolant heater power consumption VOLVO_HVCH_POWER_CONS
- Service 22
DID 4345 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310700 W
- Unit
- W
In testing for 2017 to 2025.
High-voltage coolant heater required power consumption VOLVO_HVCH_REQUIRED_POWER
- Service 22
DID 4345 - Module
D01A → 1F422E80 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310700 W
- Unit
- W
In testing for 2017 to 2025.
Interior temperature VOLVO_INTERIOR_T
- Service 22
DID 9843 - Module
D01A → 1F422E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -60 to 144 °C
- Unit
- °C
In testing for 2017 to 2025.
Outside temperature VOLVO_AAT
- Service 22
DID 200C - Module
743 → 763 - Every
20 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2017 to 2025.
Control
Brake pedal position VOLVO_BRAKE_PEDAL_POS
- Service 22
DID E504 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Brake pressure VOLVO_BRAKE_P
- Service 22
DID 2B0D - Module
760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 21845 bar
- Unit
- bar
In testing for 2017 to 2025.
Brake pressure sensor offset VOLVO_BRAKE_P_SENS_OFFSET
- Service 22
DID EE03 - Module
760 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 40.95 bar
- Unit
- bar
In testing for 2017 to 2025.
Brake switch VOLVO_BRAKE_SWITCH
- Service 22
DID D943 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
In testing for 2017 to 2025.
Front left brake disc temperature VOLVO_FL_BRAKE_DISC_T
- Service 22
DID FEE7 - Module
D016 → 1EC62E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 °C
- Unit
- °C
In testing for 2017 to 2025.
Front left brake disc temperature, calculated VOLVO_FL_BRAKE_DISC_T_CALC
- Service 22
DID EE07 - Module
760 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 918 °C
- Unit
- °C
In testing for 2017 to 2025.
Front right brake disc temperature VOLVO_FR_BRAKE_DISC_T
- Service 22
DID FEE7 - Module
D016 → 1EC62E80 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 °C
- Unit
- °C
In testing for 2017 to 2025.
Front right brake disc temperature, calculated VOLVO_FR_BRAKE_DISC_T_CALC
- Service 22
DID EE07 - Module
760 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 918 °C
- Unit
- °C
In testing for 2017 to 2025.
Left parking brake pad VOLVO_LEFT_PARKING_BRAKE
- Service 22
DID 2B1A - Module
756 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Park brake switch VOLVO_PARK_BRAKE_SWITCH
- Service 22
DID 2B14 - Module
756 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Parking brake dynamic use count VOLVO_PARKING_BRAKE_CNT_DYNAMIC
- Service 22
DID 2B21 - Module
756 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Parking brake normal 0 /maintenance 32 VOLVO_PARKING_BRAKE_NORMAL_0_32
- Service 22
DID 2B24 - Module
756 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Parking brake static use count VOLVO_PARKING_BRAKE_CNT
- Service 22
DID 2B20 - Module
756 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Rear left brake disc temperature VOLVO_RL_BRAKE_DISC_T
- Service 22
DID FEE7 - Module
D016 → 1EC62E80 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 °C
- Unit
- °C
In testing for 2017 to 2025.
Rear left brake disc temperature, calculated VOLVO_RL_BRAKE_DISC_T_CALC
- Service 22
DID EE07 - Module
760 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 918 °C
- Unit
- °C
In testing for 2017 to 2025.
Rear right brake disc temperature VOLVO_RR_BRAKE_DISC_T
- Service 22
DID FEE7 - Module
D016 → 1EC62E80 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 °C
- Unit
- °C
In testing for 2017 to 2025.
Rear right brake disc temperature, calculated VOLVO_RR_BRAKE_DISC_T_CALC
- Service 22
DID EE07 - Module
760 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 918 °C
- Unit
- °C
In testing for 2017 to 2025.
Right parking brake pad VOLVO_RIGHT_PARKING_BRAKE
- Service 22
DID 2B1A - Module
756 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Start/stop brake booster pressure VOLVO_START_STOP_BRAKE_P
- Service 22
DID EF44 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Pedals
Accelerator pedal position VOLVO_APP_POS
- Service 22
DID EE6F - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017, 2019, 2021 to 2025. Not supported for 2018, 2020.
Details
Days to next service VOLVO_SVC_DAYS
- Service 22
DID 0204 - Module
743 → 763 - Every
600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Distance to next service VOLVO_SVC_DIST
- Service 22
DID 0203 - Module
743 → 763 - Every
600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2017 to 2025.
Service level VOLVO_SVC_LEVEL
- Service 22
DID 0188 - Module
743 → 763 - Every
600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Doors
Driver door locked VOLVO_DRIVER_LOCKED
- Service 21
PID 25 - Module
745 → 765 - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2025.
Drivers door rear mirror x-axis VOLVO_DRIVERS_DOOR_REAR_X
- Service 22
DID A4A7 - Module
740 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2025.
Drivers door rear mirror y-axis VOLVO_DRIVERS_DOOR_REAR_Y
- Service 22
DID A4A8 - Module
740 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2025.
Passenger door rear mirror x-axis VOLVO_PASSENGER_DOOR_REAR_MIRROR_X
- Service 22
DID A4A8 - Module
741 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2025.
Passenger door rear mirror x-axis VOLVO_PASSENGER_DOOR_REAR_X
- Service 22
DID A4A7 - Module
741 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2017 to 2025.
Drivetrain
Motor speed VOLVO_MOTOR_RPM
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 rpm
- Unit
- rpm
In testing for 2017 to 2025.
Electrical
12V supply voltage, battery controller VOLVO_12V_V_BMS
- Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- 0 to 31.875 V
- Unit
- V
In testing for 2017 to 2025.
DC/DC activation request VOLVO_DCDC_REQ
- Service 22
DID 3022 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
DC/DC load VOLVO_DCDC_LOAD
- Service 22
DID 3495 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.21875 %
- Unit
- %
In testing for 2017 to 2025.
DC/DC output current VOLVO_DCDC_A
- Service 22
DID 3025 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2017 to 2025.
DC/DC output power VOLVO_DCDC_P
- Service 22
DID 3494 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 W
- Unit
- W
In testing for 2017 to 2025.
DC/DC output voltage VOLVO_DCDC_V
- Service 22
DID 3024 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 4 to 29.5 V
- Unit
- V
In testing for 2017 to 2025.
DC/DC voltage request VOLVO_DCDC_V_REQ
- Service 22
DID 3023 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 12 to 24.75 V
- Unit
- V
In testing for 2017 to 2025.
Power distribution 12V voltage VOLVO_USM_V
- Service 22
DID 3301 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 6 to 21.2999 V
- Unit
- V
In testing for 2017 to 2025.
Engine
- pedal position sensor VOLVO_PEDAL_POS_SENS
- Service 22
DID 2B35 - Module
760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2621 mm
- Unit
- mm
In testing for 2017 to 2025.
Accelerator pedal position VOLVO_M3_APP_ECM
- Service 22
DID F449 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2025.
Actual power VOLVO_ACT_POWER
- Service 22
DID 4A88 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 kW
- Unit
- kW
In testing for 2017 to 2025.
Adaptive cruise target vehicle VOLVO_ACC_TARGETVEHICLE
- Service 22
DID DA12 - Module
720 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Adaptive cruise time gap VOLVO_ACC_TIMEGAP
- Service 22
DID DA11 - Module
720 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 128 s
- Unit
- s
In testing for 2017 to 2025.
Air conditioning compressor module A current VOLVO_AC_COMP_MODULE
- Service 22
DID 0331 - Module
D016 → 1EC04E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 A
- Unit
- A
In testing for 2017 to 2025.
Air conditioning compressor module a status VOLVO_AC_COMP_MODULE_STAT
- Service 22
DID 032F - Module
D016 → 1EC04E80 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Air conditioning pressure VOLVO_AC_P
- Service 22
DID D900 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Air conditioning pressure VOLVO_AC_P_D016
- Service 22
DID EE34 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Air conditioning relay VOLVO_AC_RELAY
- Service 22
DID D909 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Air distribution damper motor wanted position VOLVO_AIR_DISTRIBUTION
- Service 22
DID D904 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2025.
Air distribution damper motor, actual position VOLVO_AIR_DISTRIBUTION_ACT
- Service 22
DID D909 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2025.
Air flow/cycle, mg/s VOLVO_AIR_FLOW_CYCLE_MG_S
- Service 22
DID D916 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2017 to 2025.
Air mass, desired VOLVO_AIR_MASS_DES
- Service 22
DID D91F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2017 to 2025.
Air quality sensor status VOLVO_AIR_QUALITY_SENS
- Service 22
DID DCF9 - Module
733 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
All-wheel drive coupling current VOLVO_HALDEX_CURRENT
- Service 22
DID 1945 - Module
795 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
All-wheel drive coupling current VOLVO_HALDEX_CURRENT_795
- Service 22
DID 1946 - Module
795 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
All-wheel drive coupling module temperature sensor 1 VOLVO_HALDEX_ECU_T_SENS_1
- Service 22
DID D116 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2025.
All-wheel drive coupling module temperature sensor 2 VOLVO_HALDEX_ECU_T_SENS_2
- Service 22
DID D900 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2025.
All-wheel drive coupling oil temperature VOLVO_HALDEX_OIL_T
- Service 22
DID FD04 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2017 to 2025.
All-wheel drive coupling pressure VOLVO_HALDEX_P
- Service 22
DID 1944 - Module
795 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2017 to 2025.
All-wheel drive coupling rear axle torque VOLVO_HALDEX_REAR_AXLE_TQ
- Service 22
DID D930 - Module
795 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2017 to 2025.
All-wheel drive coupling rear axle torque, requested VOLVO_HALDEX_REAR_AXLE_TQ_REQ
- Service 22
DID D953 - Module
795 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2017 to 2025.
Alternator control mode VOLVO_ALTERNATOR_CTRL_MODE
- Service 22
DID 40D1 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Alternator, amps VOLVO_ALTERNATOR_AMPS
- Service 22
DID D924 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 A
- Unit
- A
In testing for 2017 to 2025.
Automatic alignment offset VOLVO_AUTOMATIC_ALIGNMENT
- Service 22
DID A220 - Module
764 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °
- Unit
- °
In testing for 2017 to 2025.
Average charging time left VOLVO_AVG_CHG_TIME_LEFT
- Service 22
DID EEB6 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 2017 to 2025.
Battery management sensor reliable VOLVO_BAT_MANAGEMENT_SENS
- Service 22
DID 41A7 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Bonnet closed VOLVO_BONNET_CLOSED
- Service 22
DID C154 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Boost air pressure after turbocharger VOLVO_BOOST_AIR_P_AFTER
- Service 22
DID 033E - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Boost air temperature VOLVO_BOOST_AIR_T
- Service 22
DID 0341 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2017 to 2025.
Boost air temperature VOLVO_BOOST_AIR_T_7E0
- Service 22
DID 0341 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2017 to 2025.
Boost pressure VOLVO_BOOST_P
- Service 22
DID D941 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Boost pressure, desired value VOLVO_BOOST_P_DES
- Service 22
DID D9E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Boot lid sensor VOLVO_BOOT_LID_SENS
- Service 22
DID C150 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.98
- Unit
- Number
In testing for 2017 to 2025.
Burning time, hours VOLVO_BURNING_TIME_HOURS
- Service 22
DID 9A0B - Module
7E3 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2017 to 2025.
Burning time, minutes VOLVO_BURNING_TIME_MINUTES
- Service 22
DID 9A0B - Module
7E3 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Calculated load VOLVO_CALC_LOAD
Pelican can show this parameter as the engine load.
- Service 22
DID F404 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2025.
Central lock VOLVO_CENTRAL_LOCK
- Service 22
DID C259 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 2017 to 2025.
Charging VOLVO_CHG_MS_CAN
- Service 22
DID D901 - Module
791 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 254
- Unit
- Number
In testing for 2017 to 2025.
Charging state VOLVO_CHG_ST
- Service 22
DID EE1D - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Cold zone count VOLVO_CEM_COLD_ZONE
- Service 22
DID D9FE - Module
733 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Combustion air fan VOLVO_COMBUSTION_AIR_FAN
- Service 22
DID 9A06 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Compressor inlet sensor pressure VOLVO_COMP_INLET_SENS_P
- Service 22
DID 0303 - Module
D016 → 1EC04E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2017 to 2025.
Compressor inlet sensor temperature VOLVO_COMP_INLET_SENS_T
- Service 22
DID EE36 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2025.
Compressor inlet sensor temperature VOLVO_COMP_INLET_SENS_T_D016
- Service 22
DID 0303 - Module
D016 → 1EC04E80 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2017 to 2025.
Compressor outlet sensor pressure VOLVO_COMP_OUTLET_SENS_P
- Service 22
DID 0329 - Module
D016 → 1EC04E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2017 to 2025.
Compressor outlet sensor temperature VOLVO_COMP_OUTLET_SENS_T
- Service 22
DID EE38 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2025.
Compressor outlet sensor temperature VOLVO_COMP_OUTLET_SENS_T_D016
- Service 22
DID 0329 - Module
D016 → 1EC04E80 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2017 to 2025.
Control module power supply VOLVO_CTRL_MODULE_POWER
- Service 22
DID D111 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Control module temperature VOLVO_CTRL_MODULE_T
- Service 22
DID D9B8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2017 to 2025.
Coolant pump current VOLVO_ED_PUMP_A
- Service 22
DID 2309 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 A
- Unit
- A
In testing for 2017 to 2025.
Coolant pump relay VOLVO_CLT_PMP_RELAY
- Service 22
DID D95B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Coolant pump speed VOLVO_ED_PUMP_DUTY
- Service 22
DID D032 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2025.
Coolant pump temperature VOLVO_ED_PUMP_T
- Service 22
DID 230A - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2017 to 2025.
Coolant pump voltage VOLVO_ED_PUMP_V
- Service 22
DID 2308 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Coolant temperature VOLVO_ED_COOLANT_T
- Service 22
DID 2047 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 8191.875 °C
- Unit
- °C
In testing for 2017 to 2025.
Cooling fan speed VOLVO_ED_FAN_DUTY
- Service 22
DID D041 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2025.
Counter VOLVO_CNT_MS_CAN
- Service 22
DID 9A0D - Module
7E3 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Cylinder 1 misfire VOLVO_MIS_1
- Service 22
DID F6A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Cylinder 1 misfire average VOLVO_MIS_AVG_1
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Cylinder 2 misfire VOLVO_MIS_2
- Service 22
DID F6A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Cylinder 2 misfire average VOLVO_MIS_AVG_2
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Cylinder 3 misfire VOLVO_MIS_3
- Service 22
DID F6A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Cylinder 3 misfire average VOLVO_MIS_AVG_3
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Cylinder 4 misfire VOLVO_MIS_4
- Service 22
DID F6A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Cylinder 4 misfire average VOLVO_MIS_AVG_4
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Cylinder 5 misfire average VOLVO_MIS_AVG_5
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Cylinder 6 misfire average VOLVO_MIS_AVG_6
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Cylinder 7 misfire average VOLVO_MIS_AVG_7
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Cylinder 8 misfire average VOLVO_MIS_AVG_8
- Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Days since last service VOLVO_DAYS_SINCE_SERVICE
- Service 22
DID D903 - Module
D018 → 1F002E80 - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2017 to 2025.
Defroster damper motor wanted position VOLVO_DEFROSTER_DAMPER
- Service 22
DID D900 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2025.
Defroster damper motor, actual position VOLVO_DEFROSTER_DAMPER_ACT
- Service 22
DID D905 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2025.
Diesel particulate filter additive pump VOLVO_M3_ADM_ADDITIVE_PMP
- Service 22
DID D904 - Module
7C0 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2025.
Diesel particulate filter pressure VOLVO_DPF_P
- Service 22
DID DAC8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2017 to 2025.
Diesel particulate filter soot VOLVO_DPF_SOOT
- Service 22
DID D9F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655
- Unit
- Raw value
In testing for 2017 to 2025.
Diesel particulate filter temperature VOLVO_DPF_T
- Service 22
DID D9F9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2025.
Dipped beam VOLVO_DIPPED_BEAM
- Service 22
DID 7151 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Display illumination intensity VOLVO_LCD_ILUMINATION
- Service 22
DID DB01 - Module
784 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2025.
Display temperature VOLVO_DISPLAY_T_MS_CAN
- Service 22
DID D906 - Module
784 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2017 to 2025.
Distance to next service VOLVO_EQA_SERVICE_DIST
- Service 22
DID 6504 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2017 to 2025.
Downtime VOLVO_DOWNTIME
- Service 22
DID EED6 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5
- Unit
- Raw value
In testing for 2017 to 2025.
Electric drivetrain coolant temperature, IEM inlet VOLVO_ELEC_DRIVETRAIN_ECT
- Service 22
DID 985E - Module
D016 → 1EC6EE80 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483688 to 2147483607 °C
- Unit
- °C
In testing for 2017 to 2025.
Electric drivetrain coolant temperature, IEM outlet VOLVO_ELEC_DRIVETRAIN_ECT_IEM
- Service 22
DID 985E - Module
D016 → 1EC6EE80 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483688 to 2147483607 °C
- Unit
- °C
In testing for 2017 to 2025.
Electric drivetrain coolant temperature, IHFA inlet VOLVO_ELEC_DRIVETRAIN_ECT_IHFA
- Service 22
DID 985E - Module
D016 → 1ED24E80 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483688 to 2147483607 °C
- Unit
- °C
In testing for 2017 to 2025.
Electric drivetrain coolant temperature, IHFA outlet VOLVO_ELEC_DRIVETRAIN_ECT_IHFA_OUTLET
- Service 22
DID 985E - Module
D016 → 1ED24E80 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483688 to 2147483607 °C
- Unit
- °C
In testing for 2017 to 2025.
Electric front axle drive torque VOLVO_ELECTRICAL_FRONT
- Service 22
DID 49D4 - Module
D016 → 1ED24E80 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147484672 to 2147482623 N·m
- Unit
- N·m
In testing for 2017 to 2025.
Electric rear axle drive calculated torque VOLVO_ERAD_CALC_TQ
- Service 22
DID EF12 - Module
D016 → 1EC6EE80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -8188 to 253952 N·m
- Unit
- N·m
In testing for 2017 to 2025.
Electric rear axle drive calculated torque VOLVO_ERAD_CALC_TQ_D016
- Service 22
DID EE09 - Module
D016 → 1EC6EE80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -8188 to 253952 N·m
- Unit
- N·m
In testing for 2017 to 2025.
Electric rear axle drive motor winding temperature sensor 1 VOLVO_ERAD_MOTOR_WINDING_T_1
- Service 22
DID 4A00 - Module
D016 → 1EC6EE80 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 °C
- Unit
- °C
In testing for 2017 to 2025.
Electric rear axle drive motor winding temperature sensor 2 VOLVO_ERAD_MOTOR_WINDING_T_2
- Service 22
DID 4A01 - Module
D016 → 1EC6EE80 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 °C
- Unit
- °C
In testing for 2017 to 2025.
Engine coolant fan VOLVO_ENG_CLT_FAN
- Service 22
DID EE6F - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2017 to 2025.
Engine oil pressure VOLVO_EOP
- Service 22
DID EF4E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Engine oil pressure VOLVO_EOP_D016
- Service 22
DID EE37 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Engine oil temperature VOLVO_EOT
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID D9DC - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2025.
Engine oil temperature VOLVO_EOT_D016
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID EE58 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2025.
Engine time since last service VOLVO_ENG_TIME_SINCE
- Service 22
DID 630E - Module
720 - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2017 to 2025.
Engine torque VOLVO_ENG_TQ
- Service 22
DID DA89 - Module
D016 → 1EC64E80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 6041 N·m
- Unit
- N·m
In testing for 2017 to 2025.
Evaporator temperature VOLVO_EVAPORATOR_T_MS_CAN
- Service 22
DID D998 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -100 to 923 °C
- Unit
- °C
In testing for 2017 to 2025.
Exhaust gas recirculation bypass valve VOLVO_EGR_BYPASS_VLV
- Service 22
DID EE7F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2025.
Exhaust gas recirculation cooler bypass actuator position VOLVO_EGR_COOLER_BYPASS
- Service 22
DID DAD2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2017 to 2025.
Exhaust gas recirculation valve position sensor VOLVO_EGR_VLV_POS_SENS
- Service 22
DID DAAD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2017 to 2025.
Exhaust gas recirculation valve, commanded position VOLVO_EGR_VLV_CMD_POS
- Service 22
DID DC01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2017 to 2025.
Exhaust gas recirculation valve, commanded position II VOLVO_EGR_VLV_CMD_POS_II
- Service 22
DID D96D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2017 to 2025.
Fan VOLVO_FAN
- Service 22
DID DC02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2017 to 2025.
Front axle sensor VOLVO_FRONT_AXLE_SENS
- Service 22
DID 3B71 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.37 V
- Unit
- V
In testing for 2017 to 2025.
Front oxygen sensor heating VOLVO_FRONT_OXYGEN_SENS
- Service 22
DID DA59 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 ms
- Unit
- ms
In testing for 2017 to 2025.
Glow plug pulse ratio VOLVO_GLOW_PLUG_RAT_MS_CAN
- Service 22
DID 9A04 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2025.
Glow plugs VOLVO_GLOW_PLUGS
- Service 22
DID D9A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2017 to 2025.
Grill shutter open VOLVO_GRILL_SHUTTER_OPEN
- Service 22
DID 0707 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2025.
High beam VOLVO_HIGH_BEAM
- Service 22
DID 7151 - Module
726 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
High voltage coolant heater A, inlet temperature VOLVO_HIGH_V_CLT_HEATER_T
- Service 22
DID 032B - Module
D016 → 1EC04E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2017 to 2025.
High voltage coolant heater A, outlet temperature VOLVO_HIGH_V_CLT_HEATER_OUTLET_T
- Service 22
DID 032B - Module
D016 → 1EC04E80 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2017 to 2025.
High voltage ED coolant temperature 2 VOLVO_HIGH_V_ED_ECT_2
- Service 22
DID EF73 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2025.
High voltage motor coolant pump VOLVO_HIGH_V_MOTOR_CLT_PMP
- Service 22
DID EF71 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 rpm
- Unit
- rpm
In testing for 2017 to 2025.
High voltage system current VOLVO_HIGH_V_SYSTEM
- Service 22
DID EF13 - Module
D016 → 1EC6EE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -250 to 260 A
- Unit
- A
In testing for 2017 to 2025.
High voltage system current VOLVO_HIGH_V_SYSTEM_CURRENT
- Service 22
DID 9861 - Module
D016 → 1ED24E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3236 to 3316 A
- Unit
- A
In testing for 2017 to 2025.
High voltage system current VOLVO_HIGH_V_SYSTEM_V2
- Service 22
DID 9861 - Module
D016 → 1EC6EE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3236 to 3316 A
- Unit
- A
In testing for 2017 to 2025.
Ignition angle before top dead center VOLVO_IGN_ANG_BTDC
- Service 22
DID F40E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5
- Unit
- Number
In testing for 2017 to 2025.
In car temperature VOLVO_CAR_T
- Service 22
DID DD04 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
In car temperature VOLVO_CAR_T_MS_CAN_7E3
- Service 22
DID DD04 - Module
7E3 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
In-car temperature VOLVO_CAR_T_720
- Service 22
DID DD04 - Module
720 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
In-car temperature VOLVO_CAR_T_MS_CAN
- Service 22
DID 9A1B - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -100 to 923 °C
- Unit
- °C
In testing for 2017 to 2025.
Infotainment ring optical fiber test VOLVO_MOST_OPTICAL_FIBRE
- Service 22
DID 831F - Module
784 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Input torque calculated VOLVO_INPUT_TQ_CALC
- Service 22
DID D962 - Module
795 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -16376 to 507904 N·m
- Unit
- N·m
In testing for 2017 to 2025.
Input torque, requested VOLVO_INPUT_TQ_REQ
- Service 22
DID D956 - Module
795 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -16376 to 507904 N·m
- Unit
- N·m
In testing for 2017 to 2025.
Intake air temperature, manifold sensor VOLVO_TMAP_IAT
- Service 22
DID D9AB - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2017 to 2025.
Lateral angle VOLVO_LATERAL_ANG
- Service 22
DID 2B0C - Module
760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °
- Unit
- °
In testing for 2017 to 2025.
Leading A/T VOLVO_LEADING_T
- Service 22
DID 1E2F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2017 to 2025.
Left seat heater VOLVO_LEFT_SEAT_HEATER_MS
- Service 22
DID 9A21 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2017 to 2025.
Left temperature damper motor wanted position VOLVO_LEFT_T_DAMPER_MOTOR
- Service 22
DID D902 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2025.
Left temperature damper motor, actual position VOLVO_LEFT_T_DAMPER_MOTOR_ACT
- Service 22
DID D907 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2025.
Load VOLVO_LOAD
- Service 22
DID F443 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
In testing for 2017 to 2025.
M3 APP, CAN VOLVO_M3_APP_CAN
- Service 22
DID F44A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2025.
M3 diff.press. VOLVO_M3_DIFF_PRESS
- Service 22
DID D9F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2017 to 2025.
M3 DPF soot VOLVO_M3_DPF_SOOT
- Service 22
DID D9F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 g
- Unit
- g
In testing for 2017 to 2025.
M3 EGR DC VOLVO_M3_EGR_DC
- Service 22
DID D96C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2017 to 2025.
M3 IAT, butterfly VOLVO_M3_IAT_BUTTERFLY
- Service 22
DID F40F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
M3 IAT, MAF VOLVO_M3_IAT_MAF
- Service 22
DID D91C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 °C
- Unit
- °C
In testing for 2017 to 2025.
Misfire catalytic damage total - petrol VOLVO_MIS_CATALYTIC_DAMAGE
- Service 22
DID DA03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Misfire emission related total - petrol VOLVO_MIS_EMISSION_RELATED
- Service 22
DID DA04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Misfires, cylinder 2 VOLVO_MIS_2_D016
- Service 22
DID EF71 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Misfires, cylinder 3 VOLVO_MIS_3_D016
- Service 22
DID EF71 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Module current VOLVO_MODULE_CURRENT
- Service 22
DID 1946 - Module
D016 → 1EC70E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Months since last service VOLVO_MONTHS_SINCE_SERVICE
- Service 22
DID 630E - Module
720 - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 546
- Unit
- Number
In testing for 2017 to 2025.
MOST lock VOLVO_MOST_LOCK_MS_CAN
- Service 22
DID DB16 - Module
784 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
MOST network number of modules VOLVO_MOST_NETWORK_NUM
- Service 22
DID 8335 - Module
784 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Motor hours since last service VOLVO_MOTOR_HOURS_SINCE
- Service 22
DID D903 - Module
D018 → 1F002E80 - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 h
- Unit
- h
In testing for 2017 to 2025.
Navigation altitude VOLVO_SENSUS_CONNECT_GPS
- Service 22
DID 8012 - Module
784 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 364 °
- Unit
- °
In testing for 2017 to 2025.
Navigation fix VOLVO_SENSUS_CONNECT_GPS_FIX_MS
- Service 22
DID 8012 - Module
784 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 2017 to 2025.
Navigation heading VOLVO_SENSUS_CONNECT_GPS_HEADING
- Service 22
DID 8012 - Module
784 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °
- Unit
- °
In testing for 2017 to 2025.
Navigation number of satellites VOLVO_SENSUS_CONNECT_GPS_NUM
- Service 22
DID 8035 - Module
784 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
On-board charger module temperature VOLVO_OBC_T
- Service 22
DID EE19 - Module
D016 → 1EC68E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2025.
Operating state VOLVO_OP_ST_MS_CAN
- Service 22
DID 9A08 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Outdoor temperature, BCM VOLVO_OUTDOOR_T_BCM
- Service 22
DID DD05 - Module
760 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
Outside heat exchanger outlet sensor pressure VOLVO_OUTSIDE_HEAT_P
- Service 22
DID EE48 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483648 to 2147483647
- Unit
- Raw value
In testing for 2017 to 2025.
Outside heat exchanger outlet sensor temperature VOLVO_OUTSIDE_HEAT_T
- Service 22
DID EE47 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2025.
Parking heater counter VOLVO_PARKING_HEATER_CNT
- Service 22
DID 9A0E - Module
7E3 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Parking lights VOLVO_PARKING_LIGHTS
- Service 22
DID 7151 - Module
726 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Passenger airbag activated VOLVO_PASSENGER_AIRBAG_ACTIVATED
- Service 22
DID 5B29 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Passenger airbag cutoff switch VOLVO_PASSENGER_AIRBAG
- Service 22
DID 5B28 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 2017 to 2025.
Passenger airbag OFF lamp VOLVO_PASSENGER_AIRBAG_OFF
- Service 22
DID 61A5 - Module
737 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96
- Unit
- Number
In testing for 2017 to 2025.
Power mode VOLVO_POWER_MODE
- Service 22
DID DD06 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -192 to 63
- Unit
- Number
In testing for 2017 to 2025.
Power mode VOLVO_POWER_MODE_MS_CAN
- Service 22
DID DD07 - Module
784 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -99 to 156
- Unit
- Number
In testing for 2017 to 2025.
Power mode VOLVO_POWER_MODE_MS_CAN_7E3
- Service 22
DID DD06 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Quiescent current average VOLVO_QUIESCENT_CURRENT
- Service 22
DID 4025 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1000 to 31767 mA
- Unit
- mA
In testing for 2017 to 2025.
Rear axle sensor VOLVO_REAR_AXLE_SENS
- Service 22
DID 3B73 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.37 V
- Unit
- V
In testing for 2017 to 2025.
Rear defroster automatic VOLVO_REAR_DEFROSTER
- Service 22
DID D918 - Module
733 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Rear left seat heater VOLVO_RL_SEAT_HEATER_MS
- Service 22
DID 9A23 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2017 to 2025.
Rear oxygen sensor heating VOLVO_REAR_OXYGEN_SENS
- Service 22
DID DB77 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 ms
- Unit
- ms
In testing for 2017 to 2025.
Rear right seat heater VOLVO_RR_SEAT_HEATER_MS
- Service 22
DID 9A24 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2017 to 2025.
Recirculation damper motor wanted position VOLVO_RECIRCULATION_DAMPER
- Service 22
DID D901 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2025.
Recirculation damper motor, actual position VOLVO_RECIRCULATION_DAMPER_ACT
- Service 22
DID D906 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2025.
Remote key VOLVO_REMOTE_KEY
- Service 22
DID 412D - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Right seat heater VOLVO_RIGHT_SEAT_HEATER_MS
- Service 22
DID 9A22 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2017 to 2025.
Right temperature damper motor wanted position VOLVO_RIGHT_T_DAMPER_MOTOR
- Service 22
DID D903 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2025.
Right temperature damper motor, actual position VOLVO_RIGHT_T_DAMPER_MOTOR_ACT
- Service 22
DID D908 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2025.
Running time, hours VOLVO_RUNNING_TIME_HOURS
- Service 22
DID 9A0C - Module
7E3 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2017 to 2025.
Running time, minutes VOLVO_RUNNING_TIME_MINUTES
- Service 22
DID 9A0C - Module
7E3 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Seat buckle driver locked VOLVO_SEAT_BUCKLE_DRIVER
- Service 22
DID 5B19 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 2017 to 2025.
Seat buckle passenger locked VOLVO_SEAT_BUCKLE
- Service 22
DID 5B1A - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 2017 to 2025.
Seat buckle rear center locked VOLVO_SEAT_BUCKLE_REAR
- Service 22
DID 5B47 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Seat buckle rear left locked VOLVO_SEAT_BUCKLE_RL
- Service 22
DID 5B46 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Seat buckle rear right locked VOLVO_SEAT_BUCKLE_RR
- Service 22
DID 5B48 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Servo control module temperature VOLVO_SERVO_CTRL_MODULE_T
- Service 22
DID D11C - Module
730 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
Servo pump engine power consumption VOLVO_SERVO_PMP_ENG_POWER
- Service 22
DID 4139 - Module
730 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 A
- Unit
- A
In testing for 2017 to 2025.
Slave A/T VOLVO_SLAVE_T
- Service 22
DID 1E1B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2017 to 2025.
SLC1 current VOLVO_SLC1_CURRENT
- Service 22
DID D90C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
SLC2 current VOLVO_SLC2_CURRENT
- Service 22
DID D90F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
SLC3 current VOLVO_SLC3_CURRENT
- Service 22
DID D910 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Starter relay VOLVO_STARTER_RELAY
- Service 22
DID D950 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Starter relay 1 VOLVO_STARTER_RELAY_1
- Service 22
DID DA12 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Starter relay 2 VOLVO_STARTER_RELAY_2
- Service 22
DID EEEB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Steering angle, actual value VOLVO_STEER_ANG_ACT
- Service 22
DID 3302 - Module
760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2017 to 2025.
Steering shaft torque VOLVO_STEER_SHFT_TQ
- Service 22
DID 330C - Module
730 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -12.7 to 12.8 N·m
- Unit
- N·m
In testing for 2017 to 2025.
Supplementary heater counter VOLVO_SUPPLEMENTARY_HEATER
- Service 22
DID 9A0F - Module
7E3 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
System relay VOLVO_SYSTEM_RELAY
- Service 22
DID D94F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Tailgate closing motor VOLVO_TAILGATE_CLOSING
- Service 22
DID D908 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Tailgate hall sensor signal VOLVO_TAILGATE_HALL_SENS
- Service 22
DID D904 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Tailgate handle button VOLVO_TAILGATE_HANDLE
- Service 22
DID D900 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Tailgate motor protection VOLVO_TAILGATE_MOTOR
- Service 22
DID EE04 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Tailgate opening motor VOLVO_TAILGATE_OPENING
- Service 22
DID D907 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Tailgate opening position VOLVO_TAILGATE_OPENING_POS
- Service 22
DID D909 - Module
775 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Tailgate power supply VOLVO_TAILGATE_POWER_SUP
- Service 22
DID D111 - Module
775 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Tailgate switch 1-2 VOLVO_TAILGATE_SWITCH_1_2
- Service 22
DID D901 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Temperature left setting VOLVO_T_LEFT_SETTING_MS
- Service 22
DID D930 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 °C
- Unit
- °C
In testing for 2017 to 2025.
Temperature right setting VOLVO_T_RIGHT_SETTING_MS
- Service 22
DID D931 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 °C
- Unit
- °C
In testing for 2017 to 2025.
Throttle absolute position VOLVO_THROTTLE_ABS_POS
Pelican can show this parameter as the throttle position.
- Service 22
DID F411 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2025.
Time since engine start VOLVO_TIME_SINCE_ENG_START
- Service 22
DID F41F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2017 to 2025.
Torque converter lock-up solenoid VOLVO_LOCK_UP_SOLENOID_SLU_7E1
- Service 22
DID DA4C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Torque converter lock-up solenoid current VOLVO_LOCK_UP_SOLENOID_SLU_CURRENT
- Service 22
DID 1E47 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Torque converter lock-up solenoid current, requested VOLVO_LOCK_UP_SOLENOID_SLU
- Service 22
DID 1E41 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Torque converter lock-up solenoid, requested VOLVO_LOCK_UP_SOLENOID_SLU_REQ
- Service 22
DID DA4B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Torque from engine VOLVO_TQ_ENG
- Service 22
DID E501 - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2017 to 2025.
Total engine running time at last service VOLVO_TOT_ENG_RUNNING_TIME
- Service 22
DID 61CC - Module
720 - Every
30 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2017 to 2025.
Total months at last service VOLVO_TOT_MONTHS_LAST
- Service 22
DID 61CC - Module
720 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 393210
- Unit
- Raw value
In testing for 2017 to 2025.
Traction control switch indicator VOLVO_DTSC_SWITCH
- Service 22
DID 2B05 - Module
760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 2.98
- Unit
- Number
In testing for 2017 to 2025.
Transmission fixed lock-up VOLVO_FIXED_LOCK_UP
- Service 22
DID 1E24 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Transmission kickdown VOLVO_KICKDOWN
- Service 22
DID DCE4 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Transmission line pressure solenoid current VOLVO_LINEAR_P_SOLENOID_SLT
- Service 22
DID 1E40 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission line pressure solenoid current VOLVO_LINEAR_P_SOLENOID_SLT_CURRENT
- Service 22
DID DA4A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission line pressure solenoid current, requested VOLVO_LINEAR_P_SOLENOID
- Service 22
DID 1E1E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission line pressure solenoid current, requested VOLVO_LINEAR_P_SOLENOID_SLT_REQ
- Service 22
DID DA49 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SL1 current VOLVO_LINEAR_P_SOLENOID_SL1
- Service 22
DID DA4E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SL1, requested, current VOLVO_LINEAR_P_SOLENOID_SL1_REQ
- Service 22
DID DA4D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SL2 current VOLVO_LINEAR_P_SOLENOID_SL2
- Service 22
DID DA50 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SL2, requested, current VOLVO_LINEAR_P_SOLENOID_SL2_REQ
- Service 22
DID DA4F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SL3 current VOLVO_LINEAR_P_SOLENOID_SL3
- Service 22
DID DA52 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SL3, requested, current VOLVO_LINEAR_P_SOLENOID_SL3_REQ
- Service 22
DID DA51 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SLB1, requested, current VOLVO_LINEAR_P_SOLENOID_SLB1_REQ
- Service 22
DID 1E45 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SLC1 current VOLVO_LINEAR_P_SOLENOID_SLC1
- Service 22
DID 1E48 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SLC1, requested, current VOLVO_LINEAR_P_SOLENOID_SLC1_REQ
- Service 22
DID 1E42 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SLC2 current VOLVO_LINEAR_P_SOLENOID_SLC2
- Service 22
DID 1E49 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SLC2, requested, current VOLVO_LINEAR_P_SOLENOID_SLC2_REQ
- Service 22
DID 1E43 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SLC3 current VOLVO_LINEAR_P_SOLENOID_SLC3
- Service 22
DID 1E4A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission linear pressure solenoid SLC3, requested, current VOLVO_LINEAR_P_SOLENOID_SLC3_REQ
- Service 22
DID 1E44 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Transmission lock-up function VOLVO_LOCK_UP_FUNCTION
- Service 22
DID DA3C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -0.333 to 84.66
- Unit
- Number
In testing for 2017 to 2025.
Transmission selector VOLVO_SELECTOR
- Service 22
DID DCEA - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 2017 to 2025.
Transmission solenoid S1 status VOLVO_SOLENOID_S1_STAT
- Service 22
DID DD89 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Transmission solenoid S2 status VOLVO_SOLENOID_S2_STAT
- Service 22
DID DD8A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Transmission start lock - start approved VOLVO_START_LOCK_START
- Service 22
DID DF08 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2017 to 2025.
Transmission torque VOLVO_TQ
- Service 22
DID DD8D - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2017 to 2025.
Transmission torque limiting VOLVO_TQ_LIMITING
- Service 22
DID DCF0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 N·m
- Unit
- N·m
In testing for 2017 to 2025.
Trip 1 VOLVO_TRIP_1
- Service 22
DID D936 - Module
720 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km
- Unit
- km
In testing for 2017 to 2025.
Trip 2 VOLVO_TRIP_2
- Service 22
DID D937 - Module
720 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km
- Unit
- km
In testing for 2017 to 2025.
Turbo bypass valve opened VOLVO_TURBO_BYPASS_VLV
- Service 22
DID D9EE - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2025.
Turbo control valve wastegate VOLVO_TURBO_CTRL_VLV_WASTEGATE
- Service 22
DID DC10 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 800 %
- Unit
- %
In testing for 2017 to 2025.
Turbo control valve, bypass or variable nozzle VOLVO_TURBO_CTRL_VLV
- Service 22
DID DC00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 800 %
- Unit
- %
In testing for 2017 to 2025.
Twilight sensor VOLVO_TWILIGHT_SENS
- Service 22
DID 412A - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2017 to 2025.
Wastegate position VOLVO_WASTEGATE_POS
- Service 22
DID DC80 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2025.
Water cooled condenser outlet sensor temperature VOLVO_WATER_COOLED_T
- Service 22
DID EE40 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2017 to 2025.
Water temperature VOLVO_WATER_T_MS_CAN
- Service 22
DID F405 - Module
7E3 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2025.
Yaw rate sensor offset VOLVO_YAW_RATE_SENS_OFFSET
- Service 22
DID EE03 - Module
760 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 18.72
- Unit
- Raw value
In testing for 2017 to 2025.
Yaw rate signal VOLVO_YAW_RATE_SIG
- Service 22
DID 2B0B - Module
760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553 to 6553
- Unit
- Raw value
In testing for 2017 to 2025.
Fuel
Fuel filter heater VOLVO_FUEL_FLT_HEATER
- Service 22
DID DC14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Fuel filter heater VOLVO_FUEL_FLT_HEATER_7E0
- Service 22
DID DB35 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Fuel heater fan adjustment VOLVO_FUEL_HEATER_FAN_ADJ
- Service 22
DID 9A03 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2025.
Fuel high pressure VOLVO_FUEL_HIGH_P
- Service 22
DID EE4F - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.76
- Unit
- Raw value
In testing for 2017 to 2025.
Fuel level 1 of 2 VOLVO_DIM_FLI_1_2
- Service 22
DID 61D1 - Module
720 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 L
- Unit
- L
In testing for 2017 to 2025.
Fuel level 2 of 2 ejector side saddle tank VOLVO_DIM_FLI_2_2_EJECTOR
- Service 22
DID 61D0 - Module
720 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 L
- Unit
- L
In testing for 2017 to 2025.
Fuel level damped VOLVO_DIM_FLI_DAMPED
- Service 22
DID EE11 - Module
720 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 L
- Unit
- L
In testing for 2017 to 2025.
Fuel level damped VOLVO_FLI_DAMPED
- Service 22
DID EE12 - Module
720 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 L
- Unit
- L
In testing for 2017 to 2025.
Fuel level input VOLVO_FLI_INPUT
Pelican can show this parameter as the fuel tank level.
- Service 22
DID F42F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2025.
Fuel level sensor VOLVO_FLI_SENS
- Service 22
DID 4117 - Module
726 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 320 V
- Unit
- V
In testing for 2017 to 2025.
Fuel level sensor ejector side saddle tank VOLVO_FLI_SENS_EJECTOR
- Service 22
DID 4118 - Module
726 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 320 V
- Unit
- V
In testing for 2017 to 2025.
Fuel low pressure VOLVO_FUEL_LOW_P
- Service 22
DID EE57 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Fuel pressure VOLVO_FUEL_P
- Service 22
DID F423 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553500
- Unit
- Raw value
In testing for 2017 to 2025.
Fuel pressure VOLVO_FUEL_P_DA10
- Service 22
DID F40A - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Fuel pressure nominal value VOLVO_FUEL_P_NOMINAL
- Service 22
DID D9FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553500
- Unit
- Raw value
In testing for 2017 to 2025.
Fuel pressure regulator valve current VOLVO_FUEL_P_REGULATOR_VLV
- Service 22
DID D9EE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2017 to 2025.
Fuel pump low pressure side duty cycle VOLVO_FUEL_PMP_LOW_P_SIDE
- Service 22
DID EF59 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2017 to 2025.
Fuel temperature VOLVO_FUEL_T
- Service 22
DID D99C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2017 to 2025.
Fuel volume control valve VOLVO_FUEL_VOLUME_CTRL_VLV
- Service 22
DID DAD5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2017 to 2025.
Fuel volume control valve VOLVO_FUEL_VOLUME_CTRL_VLV_7E0
- Service 22
DID DC13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2017 to 2025.
Lights
Brake light switch VOLVO_BRAKE_LIGHT_SWITCH
- Service 22
DID 2B00 - Module
760 - Every
250 ms - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2025.
Movement
Accelerator pedal position VOLVO_ACCEL_PEDAL_POS
- Service 22
DID DD8E - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2017 to 2025.
Adaptive cruise set speed VOLVO_ACC_SETSPEED
- Service 22
DID DA10 - Module
720 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Air conditioning compressor module a speed VOLVO_AC_COMP_MODULE_SPD
- Service 22
DID 032F - Module
D016 → 1EC04E80 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2017 to 2025.
Cabin fan speed, requested VOLVO_CABIN_FAN_SPD_REQ_MS
- Service 22
DID D950 - Module
733 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 %
- Unit
- %
In testing for 2017 to 2025.
Driven shaft speed VOLVO_DRIVEN_SHFT_SPD
- Service 22
DID DA38 - Module
D016 → 1EC64E80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2017 to 2025.
Electric rear axle drive motor speed VOLVO_ERAD_MOTOR_SPD
- Service 22
DID 4A0E - Module
D016 → 1EC6EE80 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 rpm
- Unit
- rpm
In testing for 2017 to 2025.
Indirect tire pressure monitoring high speed calibration VOLVO_ITPMS_HIGH_SPD
- Service 22
DID FDC6 - Module
760 - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2025.
Indirect tire pressure monitoring low speed calibration VOLVO_ITPMS_LOW_SPD
- Service 22
DID FDC6 - Module
760 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2025.
Lateral acceleration sensor offset VOLVO_LATERAL
- Service 22
DID EE03 - Module
760 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.579 m/s²
- Unit
- m/s²
In testing for 2017 to 2025.
Lateral acceleration sensor stored offset VOLVO_LATERAL_ACCELEROMETER
- Service 22
DID EE04 - Module
760 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.0588 m/s²
- Unit
- m/s²
In testing for 2017 to 2025.
Radiator cooling fan 1, requested speed VOLVO_RADIATOR_COOLING_FAN_1
- Service 22
DID EE62 - Module
D016 → 1EC60E80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2017 to 2025.
Servo pump speed VOLVO_SERVO_PMP_SPD
- Service 22
DID 413C - Module
730 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5100 rpm
- Unit
- rpm
In testing for 2017 to 2025.
Servo pump speed, desired value VOLVO_SERVO_PMP_SPD_DES
- Service 22
DID 413A - Module
730 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5100 rpm
- Unit
- rpm
In testing for 2017 to 2025.
Traffic sign speed limit VOLVO_TSI_SPD
- Service 22
DID DA18 - Module
720 - Every
250 ms - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 327675 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Vehicle speed VOLVO_VSS
- Service 22
DID F40D - Module
D016 → 1EC6EE80 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Stats
Battery heater operating time VOLVO_ED_HEATER_HOURS
- Service 22
DID 6321 - Module
7E5 → 7ED - Every
600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 h
- Unit
- h
In testing for 2017 to 2025.
Coolant pump operating time VOLVO_ED_PUMP_HOURS
- Service 22
DID 6309 - Module
7E5 → 7ED - Every
600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 h
- Unit
- h
In testing for 2017 to 2025.
Cooling fan operating time VOLVO_ED_FAN_HOURS
- Service 22
DID 630A - Module
7E5 → 7ED - Every
600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 h
- Unit
- h
In testing for 2017 to 2025.
Tires
Front left wheel speed VOLVO_FL_WHL_SPD
- Service 22
DID 2B06 - Module
D016 → 1EC62E80 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Front left wheel speed VOLVO_FL_WHL_SPD_760
- Service 22
DID 2B06 - Module
760 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Front left wheel speed VOLVO_FL_WHL_SPD_795
- Service 22
DID 2B06 - Module
795 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Front left wheel speed VOLVO_FL_WHL_SPD_V2
- Service 22
DID 2B06 - Module
D016 → 1EC02E80 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Front right wheel speed VOLVO_FR_WHL_SPD
- Service 22
DID 2B07 - Module
D016 → 1EC62E80 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Front right wheel speed VOLVO_FR_WHL_SPD_760
- Service 22
DID 2B07 - Module
760 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Front right wheel speed VOLVO_FR_WHL_SPD_795
- Service 22
DID 2B07 - Module
795 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Front right wheel speed VOLVO_FR_WHL_SPD_V2
- Service 22
DID 2B07 - Module
D016 → 1EC02E80 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Rear left wheel speed VOLVO_RL_WHL_SPD
- Service 22
DID 2B08 - Module
D016 → 1EC62E80 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Rear left wheel speed VOLVO_RL_WHL_SPD_760
- Service 22
DID 2B08 - Module
760 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Rear left wheel speed VOLVO_RL_WHL_SPD_795
- Service 22
DID 2B08 - Module
795 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Rear left wheel speed VOLVO_RL_WHL_SPD_V2
- Service 22
DID 2B08 - Module
D016 → 1EC02E80 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Rear right wheel speed VOLVO_RR_WHL_SPD
- Service 22
DID 2B09 - Module
D016 → 1EC62E80 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Rear right wheel speed VOLVO_RR_WHL_SPD_760
- Service 22
DID 2B09 - Module
760 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Rear right wheel speed VOLVO_RR_WHL_SPD_795
- Service 22
DID 2B09 - Module
795 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Rear right wheel speed VOLVO_RR_WHL_SPD_V2
- Service 22
DID 2B09 - Module
D016 → 1EC02E80 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2025.
Steering wheel angle sensor offset VOLVO_SAS_STEER_WHL_ANG
- Service 22
DID EE03 - Module
760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1433 to 1433 °
- Unit
- °
In testing for 2017 to 2025.
Steering wheel angle sensor stored offset VOLVO_SAS_STEER_WHL_ANG_SENS
- Service 22
DID EE04 - Module
760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -22.42 to 22.42 °
- Unit
- °
In testing for 2017 to 2025.
Steering wheel angle velocity VOLVO_STEER_WHL_ANG
- Service 22
DID 3301 - Module
730 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020
- Unit
- Raw value
In testing for 2017 to 2025.
Tire sensor 1 battery low VOLVO_TPMS_LOWBAT_1
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bit 175 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2025.
Tire sensor 1 missing VOLVO_TPMS_MISSING_1
- Service 21
PID 79 - Module
745 → 765 - Every
60 s - Testing
Bit 207 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2025.
Tire sensor 1 pressure VOLVO_TP_1
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 49151.25 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Tire sensor 1 temperature VOLVO_TT_1
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- -30 to 225 °C
- Unit
- °C
In testing for 2017 to 2025.
Tire sensor 2 battery low VOLVO_TPMS_LOWBAT_2
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bit 174 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2025.
Tire sensor 2 missing VOLVO_TPMS_MISSING_2
- Service 21
PID 79 - Module
745 → 765 - Every
60 s - Testing
Bit 206 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2025.
Tire sensor 2 pressure VOLVO_TP_2
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 49151.25 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Tire sensor 2 temperature VOLVO_TT_2
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- -30 to 225 °C
- Unit
- °C
In testing for 2017 to 2025.
Tire sensor 3 battery low VOLVO_TPMS_LOWBAT_3
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bit 173 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2025.
Tire sensor 3 missing VOLVO_TPMS_MISSING_3
- Service 21
PID 79 - Module
745 → 765 - Every
60 s - Testing
Bit 205 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2025.
Tire sensor 3 pressure VOLVO_TP_3
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 49151.25 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Tire sensor 3 temperature VOLVO_TT_3
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- -30 to 225 °C
- Unit
- °C
In testing for 2017 to 2025.
Tire sensor 4 battery low VOLVO_TPMS_LOWBAT_4
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bit 172 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2025.
Tire sensor 4 missing VOLVO_TPMS_MISSING_4
- Service 21
PID 79 - Module
745 → 765 - Every
60 s - Testing
Bit 204 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2017 to 2025.
Tire sensor 4 pressure VOLVO_TP_4
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 49151.25 kPa
- Unit
- kPa
In testing for 2017 to 2025.
Tire sensor 4 temperature VOLVO_TT_4
- Service 21
PID 74 - Module
745 → 765 - Every
60 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
- Range
- -30 to 225 °C
- Unit
- °C
In testing for 2017 to 2025.
Transmission
A/T converter VOLVO_T_CONV
- Service 22
DID 1E14 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2017 to 2025.
AT, actual gear ratio VOLVO_ACT_GEAR_RAT
- Service 22
DID 1E16 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.99
- Unit
- Number
In testing for 2017 to 2025.
Clutch 1 temperature VOLVO_CLU_1_T
- Service 22
DID D926 - Module
D016 → 1EC64E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2025.
Clutch 2 temperature VOLVO_CLU_2_T
- Service 22
DID D940 - Module
D016 → 1EC64E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2025.
Clutch actuator 1 temperature VOLVO_CLU_ACTUATOR_1_T
- Service 22
DID D96B - Module
D016 → 1EC64E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2025.
Clutch actuator 2 temperature VOLVO_CLU_ACTUATOR_2_T
- Service 22
DID D974 - Module
D016 → 1EC64E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2025.
Clutch pump duty VOLVO_CLU_PMP_DUTY
- Service 22
DID D920 - Module
D016 → 1EC70E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2017 to 2025.
Gear VOLVO_GEAR
- Service 22
DID DA85 - Module
D016 → 1EC64E80 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Gear ratio expected VOLVO_GEAR_RAT_EXPECTED
- Service 22
DID DA47 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2017 to 2025.
Gear ratio, actual VOLVO_GEAR_RAT_ACT
- Service 22
DID DA34 - Module
D016 → 1EC64E80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.99
- Unit
- Number
In testing for 2017 to 2025.
Gear ratio, actual VOLVO_GEAR_RAT_ACT_7E1
- Service 22
DID DA34 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.99
- Unit
- Number
In testing for 2017 to 2025.
Gear ratio, requested VOLVO_GEAR_RAT_REQ
- Service 22
DID DA47 - Module
D016 → 1EC64E80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2017 to 2025.
Gear, AT position VOLVO_GEAR_POS
- Service 22
DID DA40 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2017 to 2025.
Torque converter lock VOLVO_TQ_CONV_LOCK
- Service 22
DID DA3C - Module
D016 → 1EC64E80 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Transmission expected gear ratio VOLVO_EXPECTED_GEAR_RAT
- Service 22
DID 1E19 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2017 to 2025.
Transmission fluid temperature VOLVO_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID DA3B - Module
D016 → 1EC64E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2025.
Transmission fluid temperature VOLVO_ATF_T_1E3F
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1E3F - Module
DA18 → 18 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2025.
Transmission fluid temperature VOLVO_ATF_T_7E1
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1E3F - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 °C
- Unit
- °C
In testing for 2017 to 2025.
Transmission fluid temperature VOLVO_ATF_T_D016
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID D900 - Module
D016 → 1EC64E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768000 to 32767000 °C
- Unit
- °C
In testing for 2017 to 2025.
Transmission fluid temperature VOLVO_ATF_T_D016_D016
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID D90D - Module
D016 → 1EC64E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 °C
- Unit
- °C
In testing for 2017 to 2025.
Transmission fluid temperature VOLVO_ATF_T_DA18
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID E004 - Module
DA18 → 18 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2025.
Transmission fluid temperature, variant 2 VOLVO_ATF_T_VAR_2
- Service 22
DID D904 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2025.
Transmission fluid temperature, variant 2 VOLVO_ATF_T_VAR_2_7E1
- Service 22
DID DA3B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2017 to 2025.
Transmission fluid temperature, variant 3 VOLVO_ATF_T_VAR_3
- Service 22
DID D9A1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2017 to 2025.
Transmission gear VOLVO_GEAR_7E1
- Service 22
DID DD81 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Transmission gear selector p, 0 r, 1 n, 2 d, 3 VOLVO_GEAR_SELECTOR_P_0_R_1_N_2_D_3
- Service 22
DID 6310 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2025.
Trips
All-wheel drive coupling distance VOLVO_HALDEX_DIST
- Service 22
DID DD01 - Module
795 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Distance at trip start VOLVO_TRIP_START_DIST
- Service 22
DID 01A0 - Module
743 → 763 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2017 to 2025.
Distance since last service VOLVO_DIST_SINCE_SERVICE
- Service 22
DID D903 - Module
D018 → 1F002E80 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2017 to 2025.
Distance since last service VOLVO_DIST_SINCE_SERVICE_720
- Service 22
DID 630E - Module
720 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2017 to 2025.
Distance to empty VOLVO_DIST_EMPTY_MS_CAN
Pelican can show this parameter as the fuel range.
- Service 22
DID EEFD - Module
720 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2017 to 2025.
Distance, battery controller VOLVO_BMS_ODO
- Service 21
PID 61 - Module
79B → 7BB - Every
60 s - Testing
Bits 72 to 103 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2017 to 2025.
Front left distance VOLVO_FL_DIST
- Service 22
DID B116 - Module
736 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Raw value
In testing for 2017 to 2025.
Front left inner distance VOLVO_FL_INNER_DIST
- Service 22
DID B118 - Module
736 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Raw value
In testing for 2017 to 2025.
Front right distance VOLVO_FR_DIST
- Service 22
DID B117 - Module
736 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Raw value
In testing for 2017 to 2025.
Front right inner distance VOLVO_FR_INNER_DIST
- Service 22
DID B119 - Module
736 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Raw value
In testing for 2017 to 2025.
HV battery remaining distance VOLVO_EQA_HV_RANGE
Pelican can show this parameter as the electric range.
- Service 22
DID 6502 - Module
7E5 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1000 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_MILEAGE_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
D016 → 1EC64E80 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_BCM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
760 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_CEM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
726 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_CVM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
793 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_DDM_MS_CAN
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
740 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_DIM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
720 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_FSM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
764 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_PAM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
736 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_PBM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
756 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_PDM_MS_CAN
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
741 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_PPM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
794 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_PSCM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
730 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_SAS
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
797 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_SRS
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
737 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_TCM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer VOLVO_ODO_V2
Pelican can show this parameter as the odometer.
- Service 22
DID 61BB - Module
D018 → 1F002E80 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer at last service VOLVO_ODO_LAST_SERVICE
- Service 22
DID D906 - Module
D018 → 1F002E80 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Odometer at last service VOLVO_ODO_LAST_SERVICE_720
- Service 22
DID 61CC - Module
720 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Primary, target range, m VOLVO_PRIMARY_TGT_RANGE_M
- Service 22
DID A223 - Module
764 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2025.
Rear left distance VOLVO_RL_DIST
- Service 22
DID B112 - Module
736 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Raw value
In testing for 2017 to 2025.
Rear left inner distance VOLVO_RL_INNER_DIST
- Service 22
DID B114 - Module
736 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Raw value
In testing for 2017 to 2025.
Rear right distance VOLVO_RR_DIST
- Service 22
DID B113 - Module
736 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Raw value
In testing for 2017 to 2025.
Rear right inner distance VOLVO_RR_INNER_DIST
- Service 22
DID B115 - Module
736 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Raw value
In testing for 2017 to 2025.
Time at trip start VOLVO_TRIP_START_TIME
- Service 22
DID 01A2 - Module
743 → 763 - Every
60 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 s
- Unit
- s
In testing for 2017 to 2025.
Total distance VOLVO_DEM_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
D016 → 1EC70E80 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Total distance VOLVO_TOT_DIST
- Service 22
DID DD01 - Module
D016 → 1EC6EE80 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2025.
Trip time VOLVO_TRIP_TIME
- Service 22
DID 2104 - Module
743 → 763 - Every
60 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 s
- Unit
- s
In testing for 2017 to 2025.