Volvo S80

Parameters

The Volvo S80 has 129 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery relay S80_BAT_RELAY

  • Service 22DID D953
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery relay S80_BAT_RELAY

  • Service 22DID D953
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Boost pressure after turbocharger S80_BOOST_P_AFTER

  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val131−0.053435
Range
-0.0534 to 500 kPa
Unit
kPa

In testing for 2007 to 2016.

Start/stop battery relay S80_START_STOP_BAT_RELAY

  • Service 22DID EF51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Start/stop secondary battery relay S80_START_STOP_SECONDARY

  • Service 22DID EF52
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Supercharger clutch, requested position S80_SUPERCHARGER_CLU_REQ

  • Service 22DID EE84
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Transmission control module supply voltage S80_MECU_SUP_V

  • Service 22DID DD02
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 V
Unit
V

In testing for 2007 to 2016.

Control

Brake pedal position S80_BRAKE_PEDAL_POS

  • Service 22DID E504
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Brake switch S80_BRAKE_SWITCH

  • Service 22DID D943
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100
Unit
Number

In testing for 2007 to 2016.

Start/stop brake booster pressure S80_START_STOP_BRAKE_P

  • Service 22DID EF44
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2007 to 2016.

Engine

Accelerator pedal position S80_M3_APP_ECM

  • Service 22DID F449
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2016.

Air conditioning pressure S80_AC_P

  • Service 22DID D900
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kPa
Unit
kPa

In testing for 2007 to 2016.

Air conditioning relay S80_AC_RELAY

  • Service 22DID D909
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Air flow/cycle, mg/s S80_AIR_FLOW_CYCLE_MG_S

  • Service 22DID D916
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2007 to 2016.

Air mass, desired S80_AIR_MASS_DES

  • Service 22DID D91F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2007 to 2016.

Alternator, amps S80_ALTERNATOR_AMPS

  • Service 22DID D924
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 A
Unit
A

In testing for 2007 to 2016.

Boost air temperature S80_BOOST_AIR_T_7E0

  • Service 22DID 0341
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 2007 to 2016.

Boost pressure S80_BOOST_P

  • Service 22DID D941
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 2007 to 2016.

Boost pressure, desired value S80_BOOST_P_DES

  • Service 22DID D9E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 2007 to 2016.

Calculated load S80_CALC_LOAD

Pelican can show this parameter as the engine load.

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2016.

Control module temperature S80_CTRL_MODULE_T

  • Service 22DID D9B8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 2007 to 2016.

Coolant pump relay S80_CLT_PMP_RELAY

  • Service 22DID D95B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Cylinder 1 misfire S80_MIS_1

  • Service 22DID F6A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Cylinder 1 misfire average S80_MIS_AVG_1

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2016.

Cylinder 2 misfire S80_MIS_2

  • Service 22DID F6A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Cylinder 2 misfire average S80_MIS_AVG_2

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2016.

Cylinder 3 misfire S80_MIS_3

  • Service 22DID F6A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Cylinder 3 misfire average S80_MIS_AVG_3

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2016.

Cylinder 4 misfire S80_MIS_4

  • Service 22DID F6A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Cylinder 4 misfire average S80_MIS_AVG_4

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2016.

Cylinder 5 misfire average S80_MIS_AVG_5

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2016.

Cylinder 6 misfire average S80_MIS_AVG_6

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2016.

Cylinder 7 misfire average S80_MIS_AVG_7

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2016.

Cylinder 8 misfire average S80_MIS_AVG_8

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2016.

Diesel particulate filter pressure S80_DPF_P

  • Service 22DID DAC8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2007 to 2016.

Diesel particulate filter soot S80_DPF_SOOT

  • Service 22DID D9F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 2007 to 2016.

Diesel particulate filter temperature S80_DPF_T

  • Service 22DID D9F9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2016.

Engine oil pressure S80_EOP

  • Service 22DID EF4E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 2007 to 2016.

Engine oil temperature S80_EOT

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID D9DC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2007 to 2016.

Exhaust gas recirculation bypass valve S80_EGR_BYPASS_VLV

  • Service 22DID EE7F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2007 to 2016.

Exhaust gas recirculation cooler bypass actuator position S80_EGR_COOLER_BYPASS

  • Service 22DID DAD2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2007 to 2016.

Exhaust gas recirculation valve position sensor S80_EGR_VLV_POS_SENS

  • Service 22DID DAAD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2007 to 2016.

Exhaust gas recirculation valve, commanded position S80_EGR_VLV_CMD_POS

  • Service 22DID DC01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2007 to 2016.

Exhaust gas recirculation valve, commanded position II S80_EGR_VLV_CMD_POS_II

  • Service 22DID D96D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2007 to 2016.

Fan S80_FAN

  • Service 22DID DC02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2007 to 2016.

Front oxygen sensor heating S80_FRONT_OXYGEN_SENS

  • Service 22DID DA59
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 ms
Unit
ms

In testing for 2007 to 2016.

Glow plugs S80_GLOW_PLUGS

  • Service 22DID D9A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2007 to 2016.

Grill shutter open S80_GRILL_SHUTTER_OPEN

  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2016.

Ignition angle before top dead center S80_IGN_ANG_BTDC

  • Service 22DID F40E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5
Unit
Number

In testing for 2007 to 2016.

Intake air temperature, manifold sensor S80_TMAP_IAT

  • Service 22DID D9AB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.14
Range
-3549 to 3003 °C
Unit
°C

In testing for 2007 to 2016.

Leading A/T S80_LEADING_T

  • Service 22DID 1E2F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2007 to 2016.

Load S80_LOAD

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2051
Range
0 to 25700 %
Unit
%

In testing for 2007 to 2016.

M3 APP, CAN S80_M3_APP_CAN

  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2016.

M3 diff.press. S80_M3_DIFF_PRESS

  • Service 22DID D9F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2007 to 2016.

M3 DPF soot S80_M3_DPF_SOOT

  • Service 22DID D9F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55 g
Unit
g

In testing for 2007 to 2016.

M3 EGR DC S80_M3_EGR_DC

  • Service 22DID D96C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2007 to 2016.

M3 IAT, butterfly S80_M3_IAT_BUTTERFLY

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2016.

M3 IAT, MAF S80_M3_IAT_MAF

  • Service 22DID D91C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 °C
Unit
°C

In testing for 2007 to 2016.

Misfire catalytic damage total - petrol S80_MIS_CATALYTIC_DAMAGE

  • Service 22DID DA03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2016.

Rear oxygen sensor heating S80_REAR_OXYGEN_SENS

  • Service 22DID DB77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 ms
Unit
ms

In testing for 2007 to 2016.

Slave A/T S80_SLAVE_T

  • Service 22DID 1E1B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2007 to 2016.

SLC1 current S80_SLC1_CURRENT

  • Service 22DID D90C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

SLC2 current S80_SLC2_CURRENT

  • Service 22DID D90F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

SLC3 current S80_SLC3_CURRENT

  • Service 22DID D910
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Starter relay S80_STARTER_RELAY

  • Service 22DID D950
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Starter relay 1 S80_STARTER_RELAY_1

  • Service 22DID DA12
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Starter relay 2 S80_STARTER_RELAY_2

  • Service 22DID EEEB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

System relay S80_SYSTEM_RELAY

  • Service 22DID D94F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Throttle absolute position S80_THROTTLE_ABS_POS

Pelican can show this parameter as the throttle position.

  • Service 22DID F411
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2016.

Time since engine start S80_TIME_SINCE_ENG_START

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2007 to 2016.

Torque converter lock-up solenoid S80_LOCK_UP_SOLENOID_SLU_7E1

  • Service 22DID DA4C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Torque converter lock-up solenoid current S80_LOCK_UP_SOLENOID_SLU_CURRENT

  • Service 22DID 1E47
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Torque converter lock-up solenoid current, requested S80_LOCK_UP_SOLENOID_SLU

  • Service 22DID 1E41
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Torque converter lock-up solenoid, requested S80_LOCK_UP_SOLENOID_SLU_REQ

  • Service 22DID DA4B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission fixed lock-up S80_FIXED_LOCK_UP

  • Service 22DID 1E24
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Transmission kickdown S80_KICKDOWN

  • Service 22DID DCE4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Transmission line pressure solenoid current S80_LINEAR_P_SOLENOID_SLT

  • Service 22DID 1E40
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission line pressure solenoid current S80_LINEAR_P_SOLENOID_SLT_CURRENT

  • Service 22DID DA4A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission line pressure solenoid current, requested S80_LINEAR_P_SOLENOID

  • Service 22DID 1E1E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission line pressure solenoid current, requested S80_LINEAR_P_SOLENOID_SLT_REQ

  • Service 22DID DA49
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SL1 current S80_LINEAR_P_SOLENOID_SL1

  • Service 22DID DA4E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SL1, requested, current S80_LINEAR_P_SOLENOID_SL1_REQ

  • Service 22DID DA4D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SL2 current S80_LINEAR_P_SOLENOID_SL2

  • Service 22DID DA50
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SL2, requested, current S80_LINEAR_P_SOLENOID_SL2_REQ

  • Service 22DID DA4F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SL3 current S80_LINEAR_P_SOLENOID_SL3

  • Service 22DID DA52
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SL3, requested, current S80_LINEAR_P_SOLENOID_SL3_REQ

  • Service 22DID DA51
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SLB1, requested, current S80_LINEAR_P_SOLENOID_SLB1_REQ

  • Service 22DID 1E45
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SLC1 current S80_LINEAR_P_SOLENOID_SLC1

  • Service 22DID 1E48
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SLC1, requested, current S80_LINEAR_P_SOLENOID_SLC1_REQ

  • Service 22DID 1E42
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SLC2 current S80_LINEAR_P_SOLENOID_SLC2

  • Service 22DID 1E49
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SLC2, requested, current S80_LINEAR_P_SOLENOID_SLC2_REQ

  • Service 22DID 1E43
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SLC3 current S80_LINEAR_P_SOLENOID_SLC3

  • Service 22DID 1E4A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission linear pressure solenoid SLC3, requested, current S80_LINEAR_P_SOLENOID_SLC3_REQ

  • Service 22DID 1E44
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Transmission lock-up function S80_LOCK_UP_FUNCTION

  • Service 22DID DA3C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val3−0.333333
Range
-0.333 to 84.66
Unit
Number

In testing for 2007 to 2016.

Transmission selector S80_SELECTOR

  • Service 22DID DCEA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Number

In testing for 2007 to 2016.

Transmission solenoid S1 status S80_SOLENOID_S1_STAT

  • Service 22DID DD89
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Transmission solenoid S2 status S80_SOLENOID_S2_STAT

  • Service 22DID DD8A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Transmission start lock - start approved S80_START_LOCK_START

  • Service 22DID DF08
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val255
Range
0 to 1
Unit
Number

In testing for 2007 to 2016.

Transmission torque S80_TQ

  • Service 22DID DD8D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2007 to 2016.

Transmission torque limiting S80_TQ_LIMITING

  • Service 22DID DCF0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 N·m
Unit
N·m

In testing for 2007 to 2016.

Turbo control valve wastegate S80_TURBO_CTRL_VLV_WASTEGATE

  • Service 22DID DC10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1008191
Range
0 to 800 %
Unit
%

In testing for 2007 to 2016.

Turbo control valve, bypass or variable nozzle S80_TURBO_CTRL_VLV

  • Service 22DID DC00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1008191
Range
0 to 800 %
Unit
%

In testing for 2007 to 2016.

Fuel

Fuel filter heater S80_FUEL_FLT_HEATER

  • Service 22DID DC14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Fuel filter heater S80_FUEL_FLT_HEATER_7E0

  • Service 22DID DB35
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Fuel level input S80_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2016.

Fuel pressure S80_FUEL_P

  • Service 22DID F423
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100
Range
0 to 6553500
Unit
Raw value

In testing for 2007 to 2016.

Fuel pressure nominal value S80_FUEL_P_NOMINAL

  • Service 22DID D9FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100
Range
0 to 6553500
Unit
Raw value

In testing for 2007 to 2016.

Fuel pressure regulator valve current S80_FUEL_P_REGULATOR_VLV

  • Service 22DID D9EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2007 to 2016.

Fuel pump low pressure side duty cycle S80_FUEL_PMP_LOW_P_SIDE

  • Service 22DID EF59
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2007 to 2016.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2007. Supported for 2008.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2007. Supported for 2008.

Fuel temperature S80_FUEL_T

  • Service 22DID D99C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273
Range
-3549 to 3003 °C
Unit
°C

In testing for 2007 to 2016.

Fuel volume control valve S80_FUEL_VOLUME_CTRL_VLV

  • Service 22DID DAD5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2007 to 2016.

Fuel volume control valve S80_FUEL_VOLUME_CTRL_VLV_7E0

  • Service 22DID DC13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2007 to 2016.

Movement

Accelerator pedal position S80_ACCEL_PEDAL_POS

  • Service 22DID DD8E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2007 to 2016.

Transmission

A/T converter S80_T_CONV

  • Service 22DID 1E14
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2007 to 2016.

AT, actual gear ratio S80_ACT_GEAR_RAT

  • Service 22DID 1E16
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.99
Unit
Number

In testing for 2007 to 2016.

Gear ratio expected S80_GEAR_RAT_EXPECTED

  • Service 22DID DA47
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2007 to 2016.

Gear ratio, actual S80_GEAR_RAT_ACT_7E1

  • Service 22DID DA34
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.99
Unit
Number

In testing for 2007 to 2016.

Gear, AT position S80_GEAR_POS

  • Service 22DID DA40
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2007 to 2016.

Transmission expected gear ratio S80_EXPECTED_GEAR_RAT

  • Service 22DID 1E19
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2007 to 2016.

Transmission fluid temperature S80_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E3F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 °C
Unit
°C

In testing for 2007 to 2016.

Transmission fluid temperature, variant 2 S80_ATF_T_VAR_2

  • Service 22DID D904
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2007 to 2016.

Transmission fluid temperature, variant 2 S80_ATF_T_VAR_2_7E1

  • Service 22DID DA3B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2007 to 2016.

Transmission fluid temperature, variant 3 S80_ATF_T_VAR_3

  • Service 22DID D9A1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2007 to 2016.

Transmission gear S80_GEAR_7E1

  • Service 22DID DD81
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Transmission gear selector p, 0 r, 1 n, 2 d, 3 S80_GEAR_SELECTOR_P_0_R_1_N_2_D_3

  • Service 22DID 6310
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2016.

Trips

Odometer S80_MILEAGE_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2007 to 2016.

Odometer S80_ODO_TCM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2007 to 2016.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.