Volvo EX30

Parameters

The Volvo EX30 has 801 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery state of charge VOLVO_12V_BAT_ST_CHG

  • Service 22DID 4946
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×102415625
Range
0 to 4294 %
Unit
%

In testing for 2023 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery state of charge VOLVO_12V_BAT_ST_CHG

  • Service 22DID 4946
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×102415625
Range
0 to 4294 %
Unit
%

In testing for 2023 to 2026.

12V system voltage, hd VOLVO_EQA_AUX_V_HD

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 0201
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 100 V
Unit
V

In testing for 2023 to 2026.

All-wheel drive coupling module voltage VOLVO_MECU_V

  • Service 22DID DD02
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 V
Unit
V

In testing for 2023 to 2026.

Alternator charge voltage request VOLVO_ALTERNATOR_CHG_V_REQ

  • Service 22DID 411D
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Auxiliary battery current VOLVO_AUXILIARY_BAT

  • Service 22DID 4112
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−127
Range
-127 to 128 A
Unit
A

In testing for 2023 to 2026.

Auxiliary battery temperature VOLVO_AUXILIARY_BAT_T

  • Service 22DID 40D3
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026.

Auxiliary battery voltage VOLVO_AUXILIARY_BAT_V

  • Service 22DID 417E
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Auxiliary battery voltage VOLVO_EQA_AUX_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2005
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25.9255
Range
0 to 25.9 V
Unit
V

In testing for 2023 to 2026.

Average static low range battery current VOLVO_AVG_STATIC_LOW_RANGE

  • Service 22DID 4025
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 mA
Unit
mA

In testing for 2023 to 2026.

Battery age condition VOLVO_ED_BAT_AGE

  • Service 22DID 6308
  • Module7E5 → 7ED
  • Every600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2023 to 2026.

Battery charge balance, ah VOLVO_BAT_CHG_BALANCE_AH

  • Service 22DID 41A5
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Battery charge, amps VOLVO_BAT_CHG_AMPS

  • Service 22DID 4090
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−511.7
Range
-511 to 3584 A
Unit
A

In testing for 2023 to 2026.

Battery current VOLVO_BAT_CURRENT

  • Service 22DID 4090
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−512
Range
-512 to 3583 A
Unit
A

In testing for 2023 to 2026.

Battery heater on VOLVO_ED_HEATER_ON

  • Service 22DID D302
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2023 to 2026.

Battery module 1 temperature VOLVO_ED_MOD_T1

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

Battery module 2 temperature VOLVO_ED_MOD_T2

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

Battery module 3 temperature VOLVO_ED_MOD_T3

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

Battery module 4 temperature VOLVO_ED_MOD_T4

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

Battery module 5 temperature VOLVO_ED_MOD_T5

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

Battery module 6 temperature VOLVO_ED_MOD_T6

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

Battery module 7 temperature VOLVO_ED_MOD_T7

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

Battery module 8 temperature VOLVO_ED_MOD_T8

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

Battery module 9 temperature VOLVO_ED_MOD_T9

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

Battery operating mode VOLVO_EV_MODE

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

In testing for 2023 to 2026.

Battery operation time since battery monitoring sensor reset, days VOLVO_BAT_OPERATION_TIME

  • Service 22DID 4027
  • Module726
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Battery relay VOLVO_BAT_RELAY

  • Service 22DID D953
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Battery state of charge VOLVO_BAT_ST_CHG

  • Service 22DID 4028
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2023 to 2026.

Battery state of charge VOLVO_BAT_ST_CHG_726

  • Service 22DID 4028
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2023 to 2026.

Battery temperature VOLVO_BAT_T

  • Service 22DID 4029
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Battery voltage VOLVO_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 40CD
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40+5
Range
0 to 1643 V
Unit
V

In testing for 2023 to 2026.

Battery voltage VOLVO_BAT_V_726

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

In testing for 2023 to 2026.

Boost pressure after turbocharger VOLVO_BOOST_P_AFTER

  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val131−0.053435
Range
-0.0534 to 500 kPa
Unit
kPa

In testing for 2023 to 2026.

Capacity loss VOLVO_CAP_LOSS

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 %
Unit
%

In testing for 2023 to 2026.

Cell capacity, average VOLVO_ED_CAP_AS_AVG

  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
val3600
Range
0 to 18.2041 Ah
Unit
Ah

In testing for 2023 to 2026.

Cell capacity, maximum VOLVO_ED_CAP_AS_MAX

  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val3600
Range
0 to 18.2041 Ah
Unit
Ah

In testing for 2023 to 2026.

Cell capacity, minimum VOLVO_ED_CAP_AS_MIN

  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
val3600
Range
0 to 18.2041 Ah
Unit
Ah

In testing for 2023 to 2026.

Cell voltage reference, average VOLVO_ED_ADC_V_AVG

  • Service 22DID 0207
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2023 to 2026.

Cell voltage reference, maximum VOLVO_ED_ADC_V_MAX

  • Service 22DID 0207
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val+1500
Range
1500 to 67035 mV
Unit
mV

In testing for 2023 to 2026.

Cell voltage reference, minimum VOLVO_ED_ADC_V_MIN

  • Service 22DID 0207
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val+1500
Range
1500 to 67035 mV
Unit
mV

In testing for 2023 to 2026.

Charge air pressure VOLVO_CHG_AIR_P

  • Service 22DID EE3E
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.007812
Range
0 to 511 kPa
Unit
kPa

In testing for 2023 to 2026.

Charge power limit VOLVO_CHG_POWER_LIM

  • Service 22DID 489C
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val×415625
Range
0 to 4294 kW
Unit
kW

In testing for 2023 to 2026.

Charger 12V output voltage VOLVO_ED_OBL_LV

  • Service 22DID 0226
  • Module61A → 483
  • Every10 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Charger cable current VOLVO_CHARGER_CABLE

  • Service 22DID EE8D
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−410
Range
-410 to 6143 A
Unit
A

In testing for 2023 to 2026.

Charger cooling plate temperature VOLVO_ED_OBL_PLATE_T

  • Service 22DID 0223
  • Module61A → 483
  • Every60 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Charger current set point VOLVO_ED_OBL_A_SET

  • Service 22DID 022A
  • Module61A → 483
  • Every60 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2023 to 2026.

Charger HV output current VOLVO_ED_OBL_HV_A

  • Service 22DID 0225
  • Module61A → 483
  • Every10 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val10
Range
0 to 204.7 A
Unit
A

In testing for 2023 to 2026.

Charger HV output voltage VOLVO_ED_OBL_HV

  • Service 22DID 0226
  • Module61A → 483
  • Every10 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val10
Range
0 to 819 V
Unit
V

In testing for 2023 to 2026.

Charger mains current VOLVO_ED_OBL_MAINS_A

  • Service 22DID 0225
  • Module61A → 483
  • Every10 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 204.7 A
Unit
A

In testing for 2023 to 2026.

Charger mains current, phase 1 VOLVO_OBL_A1

  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 5990.4 A
Unit
A

In testing for 2023 to 2026.

Charger mains current, phase 2 VOLVO_OBL_A2

  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 5990.4 A
Unit
A

In testing for 2023 to 2026.

Charger mains voltage VOLVO_ED_OBL_MAINS_V

  • Service 22DID 0226
  • Module61A → 483
  • Every10 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val10
Range
0 to 819 V
Unit
V

In testing for 2023 to 2026.

Charger mains voltage VOLVO_OBL_V

  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 5990.4 V
Unit
V

In testing for 2023 to 2026.

Charger power 1 VOLVO_OBL_P1

  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val2000
Range
0 to 29.952 kW
Unit
kW

In testing for 2023 to 2026.

Charger power 2 VOLVO_OBL_P2

  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val2000
Range
0 to 29.952 kW
Unit
kW

In testing for 2023 to 2026.

Charger temperature VOLVO_ED_OBL_T

  • Service 22DID 0223
  • Module61A → 483
  • Every60 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Charging cable current code VOLVO_ED_OBL_CABLE_A

  • Service 22DID 0225
  • Module61A → 483
  • Every10 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2023 to 2026.

Charging plug detected VOLVO_PLUG

Pelican can show this parameter as the plug state.

  • Service 22DID 339D
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2023 to 2026.

Charging socket lock VOLVO_CHG_SOCKET_LOCKED

  • Service 22DID EE8C
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1UNLOCKEDUnlocked
2LOCKEDLocked

In testing for 2023 to 2026.

Charging socket temperature VOLVO_ED_OBL_SOCKET_T

  • Service 22DID 0223
  • Module61A → 483
  • Every60 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Control module supply voltage VOLVO_ENG_CTRL_MODULE_SUP_V

  • Service 22DID F442
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2023 to 2026.

Control module voltage VOLVO_CTRL_MODULE_V_MS_CAN

  • Service 22DID D904
  • Module784
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2023 to 2026.

DC charger current VOLVO_DC_CHARGER_CURRENT

  • Service 22DID EE16
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 A
Unit
A

In testing for 2023 to 2026.

DC charger voltage VOLVO_DC_CHARGER_V

  • Service 22DID EE17
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2023 to 2026.

DC converter requested voltage VOLVO_EQA_CNVRTR_REQ_V

  • Service 22DID 6071
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25010000
Range
0 to 100 V
Unit
V

In testing for 2023 to 2026.

Discharge power limit VOLVO_DCHG_POWER_LIM

  • Service 22DID 489E
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val×415625
Range
0 to 4294 kW
Unit
kW

In testing for 2023 to 2026.

Estimated capacity VOLVO_CAP_EST

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val360
Range
0 to 182.0416 Ah
Unit
Ah

In testing for 2023 to 2026.

External temperature sensor, HV battery cooling module VOLVO_EXTERNAL_T_SENS

  • Service 22DID EE46
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2023 to 2026.

Front camera voltage supply VOLVO_FRONT_CAMERA_V_SUP

  • Service 22DID 9969
  • Module764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×225
Range
0 to 20.4 V
Unit
V

In testing for 2023 to 2026.

Fuse DC charging voltage VOLVO_FUSE_DC_CHG_V

  • Service 22DID 498B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2023 to 2026.

High voltage battery - voltage at IEM fuse VOLVO_HVBAT_V_IEM_FUSE

  • Service 22DID 4859
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2023 to 2026.

High voltage battery - voltage at IHFA fuse VOLVO_HVBAT_V_IHFA_FUSE

  • Service 22DID 4858
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2023 to 2026.

High voltage battery cell voltage sum VOLVO_HVBAT_CELL_VOLTAGES

  • Service 22DID 497C
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2023 to 2026.

High voltage battery contactor voltage VOLVO_HVBAT_CONTACTOR_V

  • Service 22DID 4857
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2023 to 2026.

High voltage battery coolant inlet temperature VOLVO_HVBAT_CLT_INLET_T

  • Service 22DID 4804
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2023 to 2026.

High voltage battery coolant outlet temperature VOLVO_HVBAT_CLT_OUTLET_T

  • Service 22DID 4990
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2023 to 2026.

High voltage battery current VOLVO_HVBAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Service 22DID 4802
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 A
Unit
A

In testing for 2023 to 2026.

High voltage battery negative contactor voltage VOLVO_HVBAT_NEGATIVE_V

  • Service 22DID 4A58
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 V
Unit
V

In testing for 2023 to 2026.

High voltage battery state of charge VOLVO_HVBAT_ST_CHG

Pelican can show this parameter as the state of charge.

  • Service 22DID 4801
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131 %
Unit
%

In testing for 2023 to 2026.

High voltage battery state of health VOLVO_HVBAT_ST_HEALTH

Pelican can show this parameter as the state of health.

  • Service 22DID 496D
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val100
Range
0 to 42949672 %
Unit
%

In testing for 2023 to 2026.

High voltage battery voltage VOLVO_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 4803
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2023 to 2026.

High voltage battery, average temperature VOLVO_HVBAT_AVG_T

  • Service 22DID 491B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−50
Range
-50 to 605 °C
Unit
°C

In testing for 2023 to 2026.

High voltage battery, coolant pump speed, actual VOLVO_HVBAT_CLT_PMP_SPD_ACT

  • Service 22DID 4867
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24
Range
0 to 6120 rpm
Unit
rpm

In testing for 2023 to 2026.

High voltage battery, coolant pump speed, requested VOLVO_HVBAT_CLT_PMP_SPD

  • Service 22DID 4866
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24
Range
0 to 6120 rpm
Unit
rpm

In testing for 2023 to 2026.

High voltage battery, high-voltage coolant heater fuse voltage VOLVO_HVBAT_HVCH_FUSE_V

  • Service 22DID 480A
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2023 to 2026.

High voltage battery, IEM fuse voltage VOLVO_HVBAT_IEM_FUSE_V

  • Service 22DID 4808
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2023 to 2026.

High voltage battery, IGM fuse voltage VOLVO_HVBAT_IGM_FUSE_V

  • Service 22DID 4809
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2023 to 2026.

High voltage battery, inlet coolant temperature VOLVO_HVBAT_INLET_ECT

  • Service 22DID 4804
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026.

High voltage battery, max temperature VOLVO_HVBAT_MAX_T

  • Service 22DID 4945
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val100−50
Range
-50 to 605 °C
Unit
°C

In testing for 2023 to 2026.

High voltage battery, OBC fuse voltage VOLVO_HVBAT_OBC_FUSE_V

  • Service 22DID 480B
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2023 to 2026.

High voltage system voltage VOLVO_HIGH_V_SYSTEM_V

  • Service 22DID 985C
  • ModuleD016 → 1EC6EE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 V
Unit
V

In testing for 2023 to 2026.

High voltage system voltage VOLVO_HIGH_V_SYSTEM_V_D016

  • Service 22DID 985C
  • ModuleD016 → 1ED24E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 V
Unit
V

In testing for 2023 to 2026.

Highest cell voltage VOLVO_CELL_V_MAX

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

HV battery amperage VOLVO_EQA_HV_A

  • Service 22DID 6053
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
0 to 100 A
Unit
A

In testing for 2023 to 2026.

HV battery available energy VOLVO_HV_E

  • Service 22DID 320C
  • Module7E4 → 7EC
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327.675 kWh
Unit
kWh

In testing for 2023 to 2026.

HV battery coolant temperature VOLVO_EQA_HV_COOLANT_T

  • Service 22DID 2526
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×125010000
Range
0 to 100 °C
Unit
°C

In testing for 2023 to 2026.

HV battery current VOLVO_ED_HV_A

  • Service 22DID 0203
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.9687 A
Unit
A

In testing for 2023 to 2026.

HV battery current VOLVO_HV_A

Pelican can show this parameter as the traction battery current.

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val×-132
Range
-1023.9687 to 1024 A
Unit
A

In testing for 2023 to 2026.

HV battery open-circuit voltage VOLVO_OCV

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2023 to 2026.

HV battery state of charge VOLVO_EQA_HV_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 6050
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

HV battery temperature VOLVO_ED_HV_T

  • Service 22DID 0201
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

HV battery temperature, average VOLVO_HV_T_AVG

  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

HV battery temperature, maximum VOLVO_HV_T_MAX

  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

HV battery temperature, minimum VOLVO_HV_T_MIN

  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2023 to 2026.

HV battery voltage VOLVO_ED_HV_V

  • Service 22DID 0204
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 V
Unit
V

In testing for 2023 to 2026.

HV battery voltage VOLVO_EQA_HV_V

  • Service 22DID 6075
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×251000
Range
0 to 100 V
Unit
V

In testing for 2023 to 2026.

HV battery voltage VOLVO_HV_V

Pelican can show this parameter as the traction battery voltage.

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 V
Unit
V

In testing for 2023 to 2026.

HV contactor cycles remaining VOLVO_ED_CONT_LEFT

  • Service 22DID 030B
  • Module7E7 → 7EF
  • Every600 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2023 to 2026.

HV contactor cycles remaining VOLVO_HV_CONT_LEFT

  • Service 21PID 02
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2023 to 2026.

HV contactor cycles, maximum VOLVO_ED_CONT_MAX

  • Service 22DID 030C
  • Module7E7 → 7EF
  • Every600 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2023 to 2026.

HV contactor cycles, maximum VOLVO_HV_CONT_MAX

  • Service 21PID 02
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2023 to 2026.

HV contactor state VOLVO_ED_CONTACTOR

  • Service 22DID D000
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

HV contactor state VOLVO_HV_CONTACTOR

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2023 to 2026.

HV DC fault code VOLVO_ED_DC_FAULT

  • Service 22DID 0209
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

HV isolation resistance VOLVO_ED_ISO

  • Service 22DID 0209
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65534 kΩ
Unit
kΩ

In testing for 2023 to 2026.

HV plug interlock closed VOLVO_HV_INTERLOCK_PLUG

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2023 to 2026.

Initial capacity VOLVO_CAP_INIT

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val360
Range
0 to 182.0416 Ah
Unit
Ah

In testing for 2023 to 2026.

Leakage current, 10 kilohertz VOLVO_LEAK_HF10

  • Service 22DID 5066
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.768 to 32.7669
Unit
Number

In testing for 2023 to 2026.

Leakage DC current VOLVO_LEAK_DC

  • Service 22DID 5065
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.768 to 32.7669
Unit
Number

In testing for 2023 to 2026.

Leakage diagnostic code VOLVO_LEAK_DIAG

  • Service 22DID 5064
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Leakage high-frequency current VOLVO_LEAK_HF

  • Service 22DID 5067
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.768 to 32.7669
Unit
Number

In testing for 2023 to 2026.

Leakage low-frequency current VOLVO_LEAK_LF

  • Service 22DID 5068
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.768 to 32.7669
Unit
Number

In testing for 2023 to 2026.

Lowest cell voltage VOLVO_CELL_V_MIN

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Main charger current VOLVO_MAIN_CHARGER_CURRENT

  • Service 22DID EE15
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 A
Unit
A

In testing for 2023 to 2026.

Main charger voltage VOLVO_MAIN_CHARGER_V

  • Service 22DID EE1C
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2023 to 2026.

Mains active power VOLVO_MAINS_P

  • Service 22DID 504A
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−20
Range
-20 to 45.5349 kW
Unit
kW

In testing for 2023 to 2026.

Mains current limit VOLVO_MAINS_A_LIMIT

  • Service 22DID 5070
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.768 to 32.7669
Unit
Number

In testing for 2023 to 2026.

Mains current, phase 2 VOLVO_MAINS_A_2

  • Service 22DID 503A
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−200
Range
-200 to 3895.9375 A
Unit
A

In testing for 2023 to 2026.

Mains current, phase 3 VOLVO_MAINS_A_3

  • Service 22DID 503B
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−200
Range
-200 to 3895.9375 A
Unit
A

In testing for 2023 to 2026.

Mains frequency VOLVO_MAINS_HZ

  • Service 22DID 5049
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128+10
Range
10 to 521.9921 Hz
Unit
Hz

In testing for 2023 to 2026.

Mains ground resistance VOLVO_MAINS_GND_R

  • Service 22DID 5062
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.768 to 32.7669
Unit
Number

In testing for 2023 to 2026.

Mains voltage, phases 1-2 VOLVO_MAINS_V_12

  • Service 22DID 503F
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 V
Unit
V

In testing for 2023 to 2026.

Mains voltage, phases 2-3 VOLVO_MAINS_V_23

  • Service 22DID 5041
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 V
Unit
V

In testing for 2023 to 2026.

Mains voltage, phases 3-1 VOLVO_MAINS_V_31

  • Service 22DID 5042
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 V
Unit
V

In testing for 2023 to 2026.

Module voltage VOLVO_MODULE_V

  • Service 22DID D111
  • ModuleD016 → 1EC70E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Open-circuit voltage state VOLVO_OCV_STATE

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 4
Unit
Number

In testing for 2023 to 2026.

Real state of charge, maximum VOLVO_SOC_REAL_MAX

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 %
Unit
%

In testing for 2023 to 2026.

Real state of charge, minimum VOLVO_SOC_REAL_MIN

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 %
Unit
%

In testing for 2023 to 2026.

Secondary battery charge time VOLVO_SECONDARY_BAT_CHG

  • Service 22DID EED3
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2023 to 2026.

Secondary battery needed charge time VOLVO_SECONDARY_BAT_NEEDED

  • Service 22DID EED5
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2023 to 2026.

Secondary battery relay VOLVO_SECONDARY_BAT_RELAY

  • Service 22DID 419C
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Secondary battery temperature VOLVO_SECONDARY_BAT_T_25_C

  • Service 22DID EED2
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Secondary battery voltage VOLVO_SECONDARY_BAT_V

  • Service 22DID 417E
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Secondary battery voltage average value VOLVO_SECONDARY_BAT_V_AVG

  • Service 22DID EED7
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Secondary battery voltage latest stored VOLVO_SECONDARY_BAT_V_LATEST

  • Service 22DID EED4
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Service interlock closed VOLVO_HV_INTERLOCK_SVC

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2023 to 2026.

Servo supply voltage VOLVO_SERVO_SUP_V

  • Service 22DID 413D
  • Module730
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Start/stop battery relay VOLVO_START_STOP_BAT_RELAY

  • Service 22DID EF51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Start/stop secondary battery relay VOLVO_START_STOP_SECONDARY

  • Service 22DID EF52
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

State of charge VOLVO_SOC

  • Service 22DID 4028
  • ModuleD01A → 1F402E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2023 to 2025. Not supported for 2026.

State of charge VOLVO_SOC_V2

Pelican can show this parameter as the state of charge.

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 %
Unit
%

In testing for 2023 to 2026.

State of charge recalibration state VOLVO_SOC_RECAL

  • Service 21PID 25
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2023 to 2026.

State of charge, displayed VOLVO_SOC_DISPLAY

  • Service 21PID 25
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 %
Unit
%

In testing for 2023 to 2026.

State of health VOLVO_SOH

Pelican can show this parameter as the state of health.

  • Service 21PID 61
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2023 to 2026.

State of health, raw VOLVO_ED_SOH

  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Sum of cell voltages VOLVO_HV_CELL_SUM_V

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 V
Unit
V

In testing for 2023 to 2026.

Supercharger clutch, requested position VOLVO_SUPERCHARGER_CLU_REQ

  • Service 22DID EE84
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Time with HV off VOLVO_ED_HV_OFF_TIME

  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 s
Unit
s

In testing for 2023 to 2026.

Transmission control module supply voltage VOLVO_MECU_SUP_V

  • Service 22DID DD02
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 V
Unit
V

In testing for 2023 to 2026.

Usable capacity, full VOLVO_CAP_FULL

  • Service 21PID 61
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val360
Range
-91.0222 to 91.0194 Ah
Unit
Ah

In testing for 2023 to 2026.

Voltage supply VOLVO_V_SUP

  • Service 22DID D901
  • Module737
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×225
Range
0 to 20.4 V
Unit
V

In testing for 2023 to 2026.

Voltage supply VOLVO_V_SUP_764

  • Service 22DID D112
  • Module764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×225
Range
0 to 20.4 V
Unit
V

In testing for 2023 to 2026.

Voltage supply VOLVO_V_SUP_MS_CAN

  • Service 22DID D111
  • Module791
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Voltage/power sensitive loads connected VOLVO_V_POWER_SENSITIVE

  • Service 22DID EEA2
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Cells

Cell 1 voltage VOLVO_CELL_V1

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 1 voltage VOLVO_ED_CELL_V1

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 2 voltage VOLVO_CELL_V2

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 2 voltage VOLVO_ED_CELL_V2

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 3 voltage VOLVO_CELL_V3

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 3 voltage VOLVO_ED_CELL_V3

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 4 voltage VOLVO_CELL_V4

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 4 voltage VOLVO_ED_CELL_V4

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 5 voltage VOLVO_CELL_V5

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 5 voltage VOLVO_ED_CELL_V5

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 6 voltage VOLVO_CELL_V6

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 6 voltage VOLVO_ED_CELL_V6

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 7 voltage VOLVO_CELL_V7

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 7 voltage VOLVO_ED_CELL_V7

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 8 voltage VOLVO_CELL_V8

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 8 voltage VOLVO_ED_CELL_V8

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 9 voltage VOLVO_CELL_V9

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 9 voltage VOLVO_ED_CELL_V9

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 10 voltage VOLVO_CELL_V10

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 10 voltage VOLVO_ED_CELL_V10

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 11 voltage VOLVO_CELL_V11

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 11 voltage VOLVO_ED_CELL_V11

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 12 voltage VOLVO_CELL_V12

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 12 voltage VOLVO_ED_CELL_V12

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 13 voltage VOLVO_CELL_V13

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 13 voltage VOLVO_ED_CELL_V13

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 14 voltage VOLVO_CELL_V14

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 14 voltage VOLVO_ED_CELL_V14

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 15 voltage VOLVO_CELL_V15

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 15 voltage VOLVO_ED_CELL_V15

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 16 voltage VOLVO_CELL_V16

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 16 voltage VOLVO_ED_CELL_V16

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 17 voltage VOLVO_CELL_V17

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 17 voltage VOLVO_ED_CELL_V17

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 18 voltage VOLVO_CELL_V18

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 18 voltage VOLVO_ED_CELL_V18

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 19 voltage VOLVO_CELL_V19

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 19 voltage VOLVO_ED_CELL_V19

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 20 voltage VOLVO_CELL_V20

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 20 voltage VOLVO_ED_CELL_V20

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 21 voltage VOLVO_CELL_V21

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 21 voltage VOLVO_ED_CELL_V21

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 22 voltage VOLVO_CELL_V22

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 22 voltage VOLVO_ED_CELL_V22

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 23 voltage VOLVO_CELL_V23

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 23 voltage VOLVO_ED_CELL_V23

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 24 voltage VOLVO_CELL_V24

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 24 voltage VOLVO_ED_CELL_V24

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 25 voltage VOLVO_CELL_V25

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 25 voltage VOLVO_ED_CELL_V25

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 26 voltage VOLVO_CELL_V26

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 26 voltage VOLVO_ED_CELL_V26

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 27 voltage VOLVO_CELL_V27

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 27 voltage VOLVO_ED_CELL_V27

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 28 voltage VOLVO_CELL_V28

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 28 voltage VOLVO_ED_CELL_V28

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 29 voltage VOLVO_CELL_V29

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 29 voltage VOLVO_ED_CELL_V29

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 30 voltage VOLVO_CELL_V30

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 30 voltage VOLVO_ED_CELL_V30

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 31 voltage VOLVO_CELL_V31

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 31 voltage VOLVO_ED_CELL_V31

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 32 voltage VOLVO_CELL_V32

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 32 voltage VOLVO_ED_CELL_V32

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 33 voltage VOLVO_CELL_V33

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 33 voltage VOLVO_ED_CELL_V33

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 34 voltage VOLVO_CELL_V34

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 34 voltage VOLVO_ED_CELL_V34

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 35 voltage VOLVO_CELL_V35

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 35 voltage VOLVO_ED_CELL_V35

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 36 voltage VOLVO_CELL_V36

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 36 voltage VOLVO_ED_CELL_V36

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 37 voltage VOLVO_CELL_V37

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 37 voltage VOLVO_ED_CELL_V37

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 38 voltage VOLVO_CELL_V38

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 38 voltage VOLVO_ED_CELL_V38

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 39 voltage VOLVO_CELL_V39

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 39 voltage VOLVO_ED_CELL_V39

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 40 voltage VOLVO_CELL_V40

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 40 voltage VOLVO_ED_CELL_V40

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 41 voltage VOLVO_CELL_V41

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 41 voltage VOLVO_ED_CELL_V41

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 42 voltage VOLVO_CELL_V42

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 42 voltage VOLVO_ED_CELL_V42

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 43 voltage VOLVO_CELL_V43

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 43 voltage VOLVO_ED_CELL_V43

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 44 voltage VOLVO_CELL_V44

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 44 voltage VOLVO_ED_CELL_V44

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 45 voltage VOLVO_CELL_V45

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 45 voltage VOLVO_ED_CELL_V45

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 46 voltage VOLVO_CELL_V46

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 46 voltage VOLVO_ED_CELL_V46

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 47 voltage VOLVO_CELL_V47

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 47 voltage VOLVO_ED_CELL_V47

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 48 voltage VOLVO_CELL_V48

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 48 voltage VOLVO_ED_CELL_V48

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 49 voltage VOLVO_CELL_V49

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 49 voltage VOLVO_ED_CELL_V49

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 50 voltage VOLVO_CELL_V50

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 50 voltage VOLVO_ED_CELL_V50

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 51 voltage VOLVO_CELL_V51

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 51 voltage VOLVO_ED_CELL_V51

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 52 voltage VOLVO_CELL_V52

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 52 voltage VOLVO_ED_CELL_V52

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 53 voltage VOLVO_CELL_V53

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 53 voltage VOLVO_ED_CELL_V53

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 54 voltage VOLVO_CELL_V54

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 54 voltage VOLVO_ED_CELL_V54

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 55 voltage VOLVO_CELL_V55

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 55 voltage VOLVO_ED_CELL_V55

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 56 voltage VOLVO_CELL_V56

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 56 voltage VOLVO_ED_CELL_V56

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 57 voltage VOLVO_CELL_V57

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 57 voltage VOLVO_ED_CELL_V57

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 58 voltage VOLVO_CELL_V58

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 58 voltage VOLVO_ED_CELL_V58

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 59 voltage VOLVO_CELL_V59

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 59 voltage VOLVO_ED_CELL_V59

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 60 voltage VOLVO_CELL_V60

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 60 voltage VOLVO_ED_CELL_V60

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 61 voltage VOLVO_CELL_V61

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 61 voltage VOLVO_ED_CELL_V61

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 62 voltage VOLVO_CELL_V62

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 62 voltage VOLVO_ED_CELL_V62

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 63 voltage VOLVO_CELL_V63

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 63 voltage VOLVO_ED_CELL_V63

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 64 voltage VOLVO_CELL_V64

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 64 voltage VOLVO_ED_CELL_V64

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 65 voltage VOLVO_CELL_V65

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 65 voltage VOLVO_ED_CELL_V65

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 66 voltage VOLVO_CELL_V66

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 66 voltage VOLVO_ED_CELL_V66

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 67 voltage VOLVO_CELL_V67

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 67 voltage VOLVO_ED_CELL_V67

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 68 voltage VOLVO_CELL_V68

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 68 voltage VOLVO_ED_CELL_V68

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 69 voltage VOLVO_CELL_V69

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 69 voltage VOLVO_ED_CELL_V69

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 70 voltage VOLVO_CELL_V70

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 70 voltage VOLVO_ED_CELL_V70

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 71 voltage VOLVO_CELL_V71

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 71 voltage VOLVO_ED_CELL_V71

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 72 voltage VOLVO_CELL_V72

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 72 voltage VOLVO_ED_CELL_V72

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 73 voltage VOLVO_CELL_V73

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 73 voltage VOLVO_ED_CELL_V73

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 74 voltage VOLVO_CELL_V74

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 74 voltage VOLVO_ED_CELL_V74

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 75 voltage VOLVO_CELL_V75

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 75 voltage VOLVO_ED_CELL_V75

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 76 voltage VOLVO_CELL_V76

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 76 voltage VOLVO_ED_CELL_V76

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 77 voltage VOLVO_CELL_V77

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 77 voltage VOLVO_ED_CELL_V77

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 78 voltage VOLVO_CELL_V78

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 78 voltage VOLVO_ED_CELL_V78

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 79 voltage VOLVO_CELL_V79

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 79 voltage VOLVO_ED_CELL_V79

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 80 voltage VOLVO_CELL_V80

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 80 voltage VOLVO_ED_CELL_V80

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 81 voltage VOLVO_CELL_V81

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 81 voltage VOLVO_ED_CELL_V81

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 82 voltage VOLVO_CELL_V82

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 82 voltage VOLVO_ED_CELL_V82

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 83 voltage VOLVO_CELL_V83

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 83 voltage VOLVO_ED_CELL_V83

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 84 voltage VOLVO_CELL_V84

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 84 voltage VOLVO_ED_CELL_V84

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 85 voltage VOLVO_CELL_V85

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 85 voltage VOLVO_ED_CELL_V85

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 86 voltage VOLVO_CELL_V86

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 86 voltage VOLVO_ED_CELL_V86

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 87 voltage VOLVO_CELL_V87

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 87 voltage VOLVO_ED_CELL_V87

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 88 voltage VOLVO_CELL_V88

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 88 voltage VOLVO_ED_CELL_V88

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 89 voltage VOLVO_CELL_V89

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 89 voltage VOLVO_ED_CELL_V89

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 90 voltage VOLVO_CELL_V90

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 90 voltage VOLVO_ED_CELL_V90

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 91 voltage VOLVO_CELL_V91

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 91 voltage VOLVO_ED_CELL_V91

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 92 voltage VOLVO_CELL_V92

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 92 voltage VOLVO_ED_CELL_V92

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 93 voltage VOLVO_CELL_V93

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 93 voltage VOLVO_ED_CELL_V93

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2023 to 2026.

Cell 94 voltage VOLVO_CELL_V94

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 95 voltage VOLVO_CELL_V95

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Cell 96 voltage VOLVO_CELL_V96

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2023 to 2026.

Brakes

Vacuum pump pressure 1 VOLVO_ED_VAC_P1

  • Service 22DID 2041
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2023 to 2026.

Vacuum pump pressure 2 VOLVO_ED_VAC_P2

  • Service 22DID 2043
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2023 to 2026.

Climate

Auxiliary water pump duty cycle VOLVO_AUXILIARY_WATER_PMP

  • Service 22DID 4336
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2023 to 2026.

Cabin blower command VOLVO_BLOWER

  • Service 22DID 34CB
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Evaporator temperature VOLVO_EVAPORATOR_T

  • Service 22DID 984F
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2023 to 2026.

Evaporator temperature v.2 VOLVO_EVAPORATOR_T_V_2

  • Service 22DID 9820
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×165
Range
-409 to 406 °C
Unit
°C

In testing for 2023 to 2026.

Fuel-operated heater, inlet water temperature VOLVO_FOH_INLET_WATER_T

  • Service 22DID 43BE
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Fuel-operated heater, outlet water temperature VOLVO_FOH_OUTLET_WATER_T

  • Service 22DID 43BE
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Heat exchanger temperature VOLVO_HEAT_EXCHANGER_T

  • Service 22DID 9850
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2023 to 2026.

Heat exchanger temperature v.2 VOLVO_HEAT_EXCHANGER_T_V_2

  • Service 22DID 4337
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×165
Range
-409 to 406 °C
Unit
°C

In testing for 2023 to 2026.

High-voltage coolant heater coolant inlet temperature VOLVO_HVCH_CLT_INLET_T

  • Service 22DID 4344
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

High-voltage coolant heater coolant outlet temperature VOLVO_HVCH_CLT_OUTLET_T

  • Service 22DID 4344
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

High-voltage coolant heater current consumption VOLVO_HVCH_CURRENT_CONS

  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 A
Unit
A

In testing for 2023 to 2026.

High-voltage coolant heater power consumption VOLVO_HVCH_POWER_CONS

  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×20
Range
0 to 1310700 W
Unit
W

In testing for 2023 to 2026.

High-voltage coolant heater required power consumption VOLVO_HVCH_REQUIRED_POWER

  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val×20
Range
0 to 1310700 W
Unit
W

In testing for 2023 to 2026.

Interior temperature VOLVO_INTERIOR_T

  • Service 22DID 9843
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×45−60
Range
-60 to 144 °C
Unit
°C

In testing for 2023 to 2026.

Outside temperature VOLVO_AAT

  • Service 22DID 200C
  • Module743 → 763
  • Every20 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2023 to 2026.

Control

Brake pedal position VOLVO_BRAKE_PEDAL_POS

  • Service 22DID E504
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Brake pressure VOLVO_BRAKE_P

  • Service 22DID 2B0D
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3
Range
0 to 21845 bar
Unit
bar

In testing for 2023 to 2026.

Brake pressure sensor offset VOLVO_BRAKE_P_SENS_OFFSET

  • Service 22DID EE03
  • Module760
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1600
Range
0 to 40.95 bar
Unit
bar

In testing for 2023 to 2026.

Brake switch VOLVO_BRAKE_SWITCH

  • Service 22DID D943
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100
Unit
Number

In testing for 2023 to 2026.

Front left brake disc temperature VOLVO_FL_BRAKE_DISC_T

  • Service 22DID FEE7
  • ModuleD016 → 1EC62E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2023 to 2026.

Front left brake disc temperature, calculated VOLVO_FL_BRAKE_DISC_T_CALC

  • Service 22DID EE07
  • Module760
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×185
Range
0 to 918 °C
Unit
°C

In testing for 2023 to 2026.

Front right brake disc temperature VOLVO_FR_BRAKE_DISC_T

  • Service 22DID FEE7
  • ModuleD016 → 1EC62E80
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2023 to 2026.

Front right brake disc temperature, calculated VOLVO_FR_BRAKE_DISC_T_CALC

  • Service 22DID EE07
  • Module760
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×185
Range
0 to 918 °C
Unit
°C

In testing for 2023 to 2026.

Left parking brake pad VOLVO_LEFT_PARKING_BRAKE

  • Service 22DID 2B1A
  • Module756
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Park brake switch VOLVO_PARK_BRAKE_SWITCH

  • Service 22DID 2B14
  • Module756
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Parking brake dynamic use count VOLVO_PARKING_BRAKE_CNT_DYNAMIC

  • Service 22DID 2B21
  • Module756
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Parking brake normal 0 /maintenance 32 VOLVO_PARKING_BRAKE_NORMAL_0_32

  • Service 22DID 2B24
  • Module756
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Parking brake static use count VOLVO_PARKING_BRAKE_CNT

  • Service 22DID 2B20
  • Module756
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Rear left brake disc temperature VOLVO_RL_BRAKE_DISC_T

  • Service 22DID FEE7
  • ModuleD016 → 1EC62E80
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2023 to 2026.

Rear left brake disc temperature, calculated VOLVO_RL_BRAKE_DISC_T_CALC

  • Service 22DID EE07
  • Module760
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×185
Range
0 to 918 °C
Unit
°C

In testing for 2023 to 2026.

Rear right brake disc temperature VOLVO_RR_BRAKE_DISC_T

  • Service 22DID FEE7
  • ModuleD016 → 1EC62E80
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °C
Unit
°C

In testing for 2023 to 2026.

Rear right brake disc temperature, calculated VOLVO_RR_BRAKE_DISC_T_CALC

  • Service 22DID EE07
  • Module760
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×185
Range
0 to 918 °C
Unit
°C

In testing for 2023 to 2026.

Right parking brake pad VOLVO_RIGHT_PARKING_BRAKE

  • Service 22DID 2B1A
  • Module756
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Start/stop brake booster pressure VOLVO_START_STOP_BRAKE_P

  • Service 22DID EF44
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2023 to 2026.

Pedals

Accelerator pedal position VOLVO_APP_POS

  • Service 22DID EE6F
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2023 to 2025. Not supported for 2026.

Details

Days to next service VOLVO_SVC_DAYS

  • Service 22DID 0204
  • Module743 → 763
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Distance to next service VOLVO_SVC_DIST

  • Service 22DID 0203
  • Module743 → 763
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2023 to 2026.

Service level VOLVO_SVC_LEVEL

  • Service 22DID 0188
  • Module743 → 763
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Doors

Driver door locked VOLVO_DRIVER_LOCKED

  • Service 21PID 25
  • Module745 → 765
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2023 to 2026.

Drivers door rear mirror x-axis VOLVO_DRIVERS_DOOR_REAR_X

  • Service 22DID A4A7
  • Module740
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2023 to 2026.

Drivers door rear mirror y-axis VOLVO_DRIVERS_DOOR_REAR_Y

  • Service 22DID A4A8
  • Module740
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2023 to 2026.

Passenger door rear mirror x-axis VOLVO_PASSENGER_DOOR_REAR_MIRROR_X

  • Service 22DID A4A8
  • Module741
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2023 to 2026.

Passenger door rear mirror x-axis VOLVO_PASSENGER_DOOR_REAR_X

  • Service 22DID A4A7
  • Module741
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2023 to 2026.

Drivetrain

Motor speed VOLVO_MOTOR_RPM

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

In testing for 2023 to 2026.

Electrical

12V supply voltage, battery controller VOLVO_12V_V_BMS

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val8
Range
0 to 31.875 V
Unit
V

In testing for 2023 to 2026.

DC/DC activation request VOLVO_DCDC_REQ

  • Service 22DID 3022
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

DC/DC load VOLVO_DCDC_LOAD

  • Service 22DID 3495
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.56
Range
0 to 99.21875 %
Unit
%

In testing for 2023 to 2026.

DC/DC output current VOLVO_DCDC_A

  • Service 22DID 3025
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2023 to 2026.

DC/DC output power VOLVO_DCDC_P

  • Service 22DID 3494
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 W
Unit
W

In testing for 2023 to 2026.

DC/DC output voltage VOLVO_DCDC_V

  • Service 22DID 3024
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+4
Range
4 to 29.5 V
Unit
V

In testing for 2023 to 2026.

DC/DC voltage request VOLVO_DCDC_V_REQ

  • Service 22DID 3023
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+12
Range
12 to 24.75 V
Unit
V

In testing for 2023 to 2026.

Power distribution 12V voltage VOLVO_USM_V

  • Service 22DID 3301
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.06+6
Range
6 to 21.2999 V
Unit
V

In testing for 2023 to 2026.

Engine

- pedal position sensor VOLVO_PEDAL_POS_SENS

  • Service 22DID 2B35
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val25
Range
0 to 2621 mm
Unit
mm

In testing for 2023 to 2026.

Accelerator pedal position VOLVO_M3_APP_ECM

  • Service 22DID F449
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Actual power VOLVO_ACT_POWER

  • Service 22DID 4A88
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kW
Unit
kW

In testing for 2023 to 2026.

Adaptive cruise target vehicle VOLVO_ACC_TARGETVEHICLE

  • Service 22DID DA12
  • Module720
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Adaptive cruise time gap VOLVO_ACC_TIMEGAP

  • Service 22DID DA11
  • Module720
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val2+0.5
Range
0 to 128 s
Unit
s

In testing for 2023 to 2026.

Air conditioning compressor module A current VOLVO_AC_COMP_MODULE

  • Service 22DID 0331
  • ModuleD016 → 1EC04E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 A
Unit
A

In testing for 2023 to 2026.

Air conditioning compressor module a status VOLVO_AC_COMP_MODULE_STAT

  • Service 22DID 032F
  • ModuleD016 → 1EC04E80
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Air conditioning pressure VOLVO_AC_P

  • Service 22DID D900
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kPa
Unit
kPa

In testing for 2023 to 2026.

Air conditioning pressure VOLVO_AC_P_D016

  • Service 22DID EE34
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534 kPa
Unit
kPa

In testing for 2023 to 2026.

Air conditioning relay VOLVO_AC_RELAY

  • Service 22DID D909
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Air distribution damper motor wanted position VOLVO_AIR_DISTRIBUTION

  • Service 22DID D904
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2023 to 2026.

Air distribution damper motor, actual position VOLVO_AIR_DISTRIBUTION_ACT

  • Service 22DID D909
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2023 to 2026.

Air flow/cycle, mg/s VOLVO_AIR_FLOW_CYCLE_MG_S

  • Service 22DID D916
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2023 to 2026.

Air mass, desired VOLVO_AIR_MASS_DES

  • Service 22DID D91F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2023 to 2026.

Air quality sensor status VOLVO_AIR_QUALITY_SENS

  • Service 22DID DCF9
  • Module733
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

All-wheel drive coupling current VOLVO_HALDEX_CURRENT

  • Service 22DID 1945
  • Module795
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

All-wheel drive coupling current VOLVO_HALDEX_CURRENT_795

  • Service 22DID 1946
  • Module795
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

All-wheel drive coupling module temperature sensor 1 VOLVO_HALDEX_ECU_T_SENS_1

  • Service 22DID D116
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2023 to 2026.

All-wheel drive coupling module temperature sensor 2 VOLVO_HALDEX_ECU_T_SENS_2

  • Service 22DID D900
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2023 to 2026.

All-wheel drive coupling oil temperature VOLVO_HALDEX_OIL_T

  • Service 22DID FD04
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2023 to 2026.

All-wheel drive coupling pressure VOLVO_HALDEX_P

  • Service 22DID 1944
  • Module795
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2023 to 2026.

All-wheel drive coupling rear axle torque VOLVO_HALDEX_REAR_AXLE_TQ

  • Service 22DID D930
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2023 to 2026.

All-wheel drive coupling rear axle torque, requested VOLVO_HALDEX_REAR_AXLE_TQ_REQ

  • Service 22DID D953
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2023 to 2026.

Alternator control mode VOLVO_ALTERNATOR_CTRL_MODE

  • Service 22DID 40D1
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Alternator, amps VOLVO_ALTERNATOR_AMPS

  • Service 22DID D924
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 A
Unit
A

In testing for 2023 to 2026.

Automatic alignment offset VOLVO_AUTOMATIC_ALIGNMENT

  • Service 22DID A220
  • Module764
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 2023 to 2026.

Average charging time left VOLVO_AVG_CHG_TIME_LEFT

  • Service 22DID EEB6
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2023 to 2026.

Battery management sensor reliable VOLVO_BAT_MANAGEMENT_SENS

  • Service 22DID 41A7
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Bonnet closed VOLVO_BONNET_CLOSED

  • Service 22DID C154
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Boost air pressure after turbocharger VOLVO_BOOST_AIR_P_AFTER

  • Service 22DID 033E
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 kPa
Unit
kPa

In testing for 2023 to 2026.

Boost air temperature VOLVO_BOOST_AIR_T

  • Service 22DID 0341
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 2023 to 2026.

Boost air temperature VOLVO_BOOST_AIR_T_7E0

  • Service 22DID 0341
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 2023 to 2026.

Boost pressure VOLVO_BOOST_P

  • Service 22DID D941
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 2023 to 2026.

Boost pressure, desired value VOLVO_BOOST_P_DES

  • Service 22DID D9E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 2023 to 2026.

Boot lid sensor VOLVO_BOOT_LID_SENS

  • Service 22DID C150
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val64
Range
0 to 3.98
Unit
Number

In testing for 2023 to 2026.

Burning time, hours VOLVO_BURNING_TIME_HOURS

  • Service 22DID 9A0B
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2023 to 2026.

Burning time, minutes VOLVO_BURNING_TIME_MINUTES

  • Service 22DID 9A0B
  • Module7E3
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Calculated load VOLVO_CALC_LOAD

Pelican can show this parameter as the engine load.

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Central lock VOLVO_CENTRAL_LOCK

  • Service 22DID C259
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Number

In testing for 2023 to 2026.

Charging VOLVO_CHG_MS_CAN

  • Service 22DID D901
  • Module791
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−1
Range
-1 to 254
Unit
Number

In testing for 2023 to 2026.

Charging state VOLVO_CHG_ST

  • Service 22DID EE1D
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Cold zone count VOLVO_CEM_COLD_ZONE

  • Service 22DID D9FE
  • Module733
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Combustion air fan VOLVO_COMBUSTION_AIR_FAN

  • Service 22DID 9A06
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Compressor inlet sensor pressure VOLVO_COMP_INLET_SENS_P

  • Service 22DID 0303
  • ModuleD016 → 1EC04E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2023 to 2026.

Compressor inlet sensor temperature VOLVO_COMP_INLET_SENS_T

  • Service 22DID EE36
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2023 to 2026.

Compressor inlet sensor temperature VOLVO_COMP_INLET_SENS_T_D016

  • Service 22DID 0303
  • ModuleD016 → 1EC04E80
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2023 to 2026.

Compressor outlet sensor pressure VOLVO_COMP_OUTLET_SENS_P

  • Service 22DID 0329
  • ModuleD016 → 1EC04E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2023 to 2026.

Compressor outlet sensor temperature VOLVO_COMP_OUTLET_SENS_T

  • Service 22DID EE38
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2023 to 2026.

Compressor outlet sensor temperature VOLVO_COMP_OUTLET_SENS_T_D016

  • Service 22DID 0329
  • ModuleD016 → 1EC04E80
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2023 to 2026.

Control module power supply VOLVO_CTRL_MODULE_POWER

  • Service 22DID D111
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Control module temperature VOLVO_CTRL_MODULE_T

  • Service 22DID D9B8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 2023 to 2026.

Coolant pump current VOLVO_ED_PUMP_A

  • Service 22DID 2309
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val5
Range
0 to 51 A
Unit
A

In testing for 2023 to 2026.

Coolant pump relay VOLVO_CLT_PMP_RELAY

  • Service 22DID D95B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Coolant pump speed VOLVO_ED_PUMP_DUTY

  • Service 22DID D032
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Coolant pump temperature VOLVO_ED_PUMP_T

  • Service 22DID 230A
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026.

Coolant pump voltage VOLVO_ED_PUMP_V

  • Service 22DID 2308
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Coolant temperature VOLVO_ED_COOLANT_T

  • Service 22DID 2047
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191.875 °C
Unit
°C

In testing for 2023 to 2026.

Cooling fan speed VOLVO_ED_FAN_DUTY

  • Service 22DID D041
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Counter VOLVO_CNT_MS_CAN

  • Service 22DID 9A0D
  • Module7E3
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Cylinder 1 misfire VOLVO_MIS_1

  • Service 22DID F6A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Cylinder 1 misfire average VOLVO_MIS_AVG_1

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Cylinder 2 misfire VOLVO_MIS_2

  • Service 22DID F6A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Cylinder 2 misfire average VOLVO_MIS_AVG_2

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Cylinder 3 misfire VOLVO_MIS_3

  • Service 22DID F6A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Cylinder 3 misfire average VOLVO_MIS_AVG_3

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Cylinder 4 misfire VOLVO_MIS_4

  • Service 22DID F6A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Cylinder 4 misfire average VOLVO_MIS_AVG_4

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Cylinder 5 misfire average VOLVO_MIS_AVG_5

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Cylinder 6 misfire average VOLVO_MIS_AVG_6

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Cylinder 7 misfire average VOLVO_MIS_AVG_7

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Cylinder 8 misfire average VOLVO_MIS_AVG_8

  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Days since last service VOLVO_DAYS_SINCE_SERVICE

  • Service 22DID D903
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2023 to 2026.

Defroster damper motor wanted position VOLVO_DEFROSTER_DAMPER

  • Service 22DID D900
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2023 to 2026.

Defroster damper motor, actual position VOLVO_DEFROSTER_DAMPER_ACT

  • Service 22DID D905
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2023 to 2026.

Diesel particulate filter additive pump VOLVO_M3_ADM_ADDITIVE_PMP

  • Service 22DID D904
  • Module7C0
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2023 to 2026.

Diesel particulate filter pressure VOLVO_DPF_P

  • Service 22DID DAC8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2023 to 2026.

Diesel particulate filter soot VOLVO_DPF_SOOT

  • Service 22DID D9F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 2023 to 2026.

Diesel particulate filter temperature VOLVO_DPF_T

  • Service 22DID D9F9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2023 to 2026.

Dipped beam VOLVO_DIPPED_BEAM

  • Service 22DID 7151
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Display illumination intensity VOLVO_LCD_ILUMINATION

  • Service 22DID DB01
  • Module784
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2023 to 2026.

Display temperature VOLVO_DISPLAY_T_MS_CAN

  • Service 22DID D906
  • Module784
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Number

In testing for 2023 to 2026.

Distance to next service VOLVO_EQA_SERVICE_DIST

  • Service 22DID 6504
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2023 to 2026.

Downtime VOLVO_DOWNTIME

  • Service 22DID EED6
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 2023 to 2026.

Electric drivetrain coolant temperature, IEM inlet VOLVO_ELEC_DRIVETRAIN_ECT

  • Service 22DID 985E
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val−40
Range
-2147483688 to 2147483607 °C
Unit
°C

In testing for 2023 to 2026.

Electric drivetrain coolant temperature, IEM outlet VOLVO_ELEC_DRIVETRAIN_ECT_IEM

  • Service 22DID 985E
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
val−40
Range
-2147483688 to 2147483607 °C
Unit
°C

In testing for 2023 to 2026.

Electric drivetrain coolant temperature, IHFA inlet VOLVO_ELEC_DRIVETRAIN_ECT_IHFA

  • Service 22DID 985E
  • ModuleD016 → 1ED24E80
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val−40
Range
-2147483688 to 2147483607 °C
Unit
°C

In testing for 2023 to 2026.

Electric drivetrain coolant temperature, IHFA outlet VOLVO_ELEC_DRIVETRAIN_ECT_IHFA_OUTLET

  • Service 22DID 985E
  • ModuleD016 → 1ED24E80
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
val−40
Range
-2147483688 to 2147483607 °C
Unit
°C

In testing for 2023 to 2026.

Electric front axle drive torque VOLVO_ELECTRICAL_FRONT

  • Service 22DID 49D4
  • ModuleD016 → 1ED24E80
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val−1024
Range
-2147484672 to 2147482623 N·m
Unit
N·m

In testing for 2023 to 2026.

Electric rear axle drive calculated torque VOLVO_ERAD_CALC_TQ

  • Service 22DID EF12
  • ModuleD016 → 1EC6EE80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4−8188
Range
-8188 to 253952 N·m
Unit
N·m

In testing for 2023 to 2026.

Electric rear axle drive calculated torque VOLVO_ERAD_CALC_TQ_D016

  • Service 22DID EE09
  • ModuleD016 → 1EC6EE80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4−8188
Range
-8188 to 253952 N·m
Unit
N·m

In testing for 2023 to 2026.

Electric rear axle drive motor winding temperature sensor 1 VOLVO_ERAD_MOTOR_WINDING_T_1

  • Service 22DID 4A00
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 °C
Unit
°C

In testing for 2023 to 2026.

Electric rear axle drive motor winding temperature sensor 2 VOLVO_ERAD_MOTOR_WINDING_T_2

  • Service 22DID 4A01
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 °C
Unit
°C

In testing for 2023 to 2026.

Engine coolant fan VOLVO_ENG_CLT_FAN

  • Service 22DID EE6F
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2023 to 2026.

Engine oil pressure VOLVO_EOP

  • Service 22DID EF4E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 2023 to 2026.

Engine oil pressure VOLVO_EOP_D016

  • Service 22DID EE37
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 2023 to 2026.

Engine oil temperature VOLVO_EOT

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID D9DC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2023 to 2026.

Engine oil temperature VOLVO_EOT_D016

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID EE58
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2023 to 2026.

Engine time since last service VOLVO_ENG_TIME_SINCE

  • Service 22DID 630E
  • Module720
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2023 to 2026.

Engine torque VOLVO_ENG_TQ

  • Service 22DID DA89
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−512
Range
-512 to 6041 N·m
Unit
N·m

In testing for 2023 to 2026.

Evaporator temperature VOLVO_EVAPORATOR_T_MS_CAN

  • Service 22DID D998
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−100
Range
-100 to 923 °C
Unit
°C

In testing for 2023 to 2026.

Exhaust gas recirculation bypass valve VOLVO_EGR_BYPASS_VLV

  • Service 22DID EE7F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2023 to 2026.

Exhaust gas recirculation cooler bypass actuator position VOLVO_EGR_COOLER_BYPASS

  • Service 22DID DAD2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2023 to 2026.

Exhaust gas recirculation valve position sensor VOLVO_EGR_VLV_POS_SENS

  • Service 22DID DAAD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2023 to 2026.

Exhaust gas recirculation valve, commanded position VOLVO_EGR_VLV_CMD_POS

  • Service 22DID DC01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2023 to 2026.

Exhaust gas recirculation valve, commanded position II VOLVO_EGR_VLV_CMD_POS_II

  • Service 22DID D96D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2023 to 2026.

Fan VOLVO_FAN

  • Service 22DID DC02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2023 to 2026.

Front axle sensor VOLVO_FRONT_AXLE_SENS

  • Service 22DID 3B71
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.37 V
Unit
V

In testing for 2023 to 2026.

Front oxygen sensor heating VOLVO_FRONT_OXYGEN_SENS

  • Service 22DID DA59
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 ms
Unit
ms

In testing for 2023 to 2026.

Glow plug pulse ratio VOLVO_GLOW_PLUG_RAT_MS_CAN

  • Service 22DID 9A04
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Glow plugs VOLVO_GLOW_PLUGS

  • Service 22DID D9A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2023 to 2026.

Grill shutter open VOLVO_GRILL_SHUTTER_OPEN

  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

High beam VOLVO_HIGH_BEAM

  • Service 22DID 7151
  • Module726
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

High voltage coolant heater A, inlet temperature VOLVO_HIGH_V_CLT_HEATER_T

  • Service 22DID 032B
  • ModuleD016 → 1EC04E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2023 to 2026.

High voltage coolant heater A, outlet temperature VOLVO_HIGH_V_CLT_HEATER_OUTLET_T

  • Service 22DID 032B
  • ModuleD016 → 1EC04E80
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2023 to 2026.

High voltage ED coolant temperature 2 VOLVO_HIGH_V_ED_ECT_2

  • Service 22DID EF73
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2023 to 2026.

High voltage motor coolant pump VOLVO_HIGH_V_MOTOR_CLT_PMP

  • Service 22DID EF71
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 rpm
Unit
rpm

In testing for 2023 to 2026.

High voltage system current VOLVO_HIGH_V_SYSTEM

  • Service 22DID EF13
  • ModuleD016 → 1EC6EE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−250
Range
-250 to 260 A
Unit
A

In testing for 2023 to 2026.

High voltage system current VOLVO_HIGH_V_SYSTEM_CURRENT

  • Service 22DID 9861
  • ModuleD016 → 1ED24E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10+40
Range
-3236 to 3316 A
Unit
A

In testing for 2023 to 2026.

High voltage system current VOLVO_HIGH_V_SYSTEM_V2

  • Service 22DID 9861
  • ModuleD016 → 1EC6EE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10+40
Range
-3236 to 3316 A
Unit
A

In testing for 2023 to 2026.

Ignition angle before top dead center VOLVO_IGN_ANG_BTDC

  • Service 22DID F40E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5
Unit
Number

In testing for 2023 to 2026.

In car temperature VOLVO_CAR_T

  • Service 22DID DD04
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

In car temperature VOLVO_CAR_T_MS_CAN_7E3

  • Service 22DID DD04
  • Module7E3
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

In-car temperature VOLVO_CAR_T_720

  • Service 22DID DD04
  • Module720
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

In-car temperature VOLVO_CAR_T_MS_CAN

  • Service 22DID 9A1B
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−100
Range
-100 to 923 °C
Unit
°C

In testing for 2023 to 2026.

Infotainment ring optical fiber test VOLVO_MOST_OPTICAL_FIBRE

  • Service 22DID 831F
  • Module784
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Input torque calculated VOLVO_INPUT_TQ_CALC

  • Service 22DID D962
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8−16376
Range
-16376 to 507904 N·m
Unit
N·m

In testing for 2023 to 2026.

Input torque, requested VOLVO_INPUT_TQ_REQ

  • Service 22DID D956
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8−16376
Range
-16376 to 507904 N·m
Unit
N·m

In testing for 2023 to 2026.

Intake air temperature, manifold sensor VOLVO_TMAP_IAT

  • Service 22DID D9AB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.14
Range
-3549 to 3003 °C
Unit
°C

In testing for 2023 to 2026.

Lateral angle VOLVO_LATERAL_ANG

  • Service 22DID 2B0C
  • Module760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °
Unit
°

In testing for 2023 to 2026.

Leading A/T VOLVO_LEADING_T

  • Service 22DID 1E2F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2023 to 2026.

Left seat heater VOLVO_LEFT_SEAT_HEATER_MS

  • Service 22DID 9A21
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2023 to 2026.

Left temperature damper motor wanted position VOLVO_LEFT_T_DAMPER_MOTOR

  • Service 22DID D902
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2023 to 2026.

Left temperature damper motor, actual position VOLVO_LEFT_T_DAMPER_MOTOR_ACT

  • Service 22DID D907
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2023 to 2026.

Load VOLVO_LOAD

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2051
Range
0 to 25700 %
Unit
%

In testing for 2023 to 2026.

M3 APP, CAN VOLVO_M3_APP_CAN

  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

M3 diff.press. VOLVO_M3_DIFF_PRESS

  • Service 22DID D9F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2023 to 2026.

M3 DPF soot VOLVO_M3_DPF_SOOT

  • Service 22DID D9F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55 g
Unit
g

In testing for 2023 to 2026.

M3 EGR DC VOLVO_M3_EGR_DC

  • Service 22DID D96C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2023 to 2026.

M3 IAT, butterfly VOLVO_M3_IAT_BUTTERFLY

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

M3 IAT, MAF VOLVO_M3_IAT_MAF

  • Service 22DID D91C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 °C
Unit
°C

In testing for 2023 to 2026.

Misfire catalytic damage total - petrol VOLVO_MIS_CATALYTIC_DAMAGE

  • Service 22DID DA03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Misfires, cylinder 2 VOLVO_MIS_2_D016

  • Service 22DID EF71
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Misfires, cylinder 3 VOLVO_MIS_3_D016

  • Service 22DID EF71
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Module current VOLVO_MODULE_CURRENT

  • Service 22DID 1946
  • ModuleD016 → 1EC70E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Months since last service VOLVO_MONTHS_SINCE_SERVICE

  • Service 22DID 630E
  • Module720
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val120
Range
0 to 546
Unit
Number

In testing for 2023 to 2026.

MOST lock VOLVO_MOST_LOCK_MS_CAN

  • Service 22DID DB16
  • Module784
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

MOST network number of modules VOLVO_MOST_NETWORK_NUM

  • Service 22DID 8335
  • Module784
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Motor hours since last service VOLVO_MOTOR_HOURS_SINCE

  • Service 22DID D903
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2023 to 2026.

Navigation altitude VOLVO_SENSUS_CONNECT_GPS

  • Service 22DID 8012
  • Module784
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val180
Range
0 to 364 °
Unit
°

In testing for 2023 to 2026.

Navigation fix VOLVO_SENSUS_CONNECT_GPS_FIX_MS

  • Service 22DID 8012
  • Module784
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2023 to 2026.

Navigation heading VOLVO_SENSUS_CONNECT_GPS_HEADING

  • Service 22DID 8012
  • Module784
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 2023 to 2026.

Navigation number of satellites VOLVO_SENSUS_CONNECT_GPS_NUM

  • Service 22DID 8035
  • Module784
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

On-board charger module temperature VOLVO_OBC_T

  • Service 22DID EE19
  • ModuleD016 → 1EC68E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2023 to 2026.

Operating state VOLVO_OP_ST_MS_CAN

  • Service 22DID 9A08
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Outdoor temperature, BCM VOLVO_OUTDOOR_T_BCM

  • Service 22DID DD05
  • Module760
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Outside heat exchanger outlet sensor pressure VOLVO_OUTSIDE_HEAT_P

  • Service 22DID EE48
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647
Unit
Raw value

In testing for 2023 to 2026.

Outside heat exchanger outlet sensor temperature VOLVO_OUTSIDE_HEAT_T

  • Service 22DID EE47
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2023 to 2026.

Parking heater counter VOLVO_PARKING_HEATER_CNT

  • Service 22DID 9A0E
  • Module7E3
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Parking lights VOLVO_PARKING_LIGHTS

  • Service 22DID 7151
  • Module726
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Passenger airbag activated VOLVO_PASSENGER_AIRBAG_ACTIVATED

  • Service 22DID 5B29
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Passenger airbag cutoff switch VOLVO_PASSENGER_AIRBAG

  • Service 22DID 5B28
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Number

In testing for 2023 to 2026.

Passenger airbag OFF lamp VOLVO_PASSENGER_AIRBAG_OFF

  • Service 22DID 61A5
  • Module737
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96
Unit
Number

In testing for 2023 to 2026.

Power mode VOLVO_POWER_MODE

  • Service 22DID DD06
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−192
Range
-192 to 63
Unit
Number

In testing for 2023 to 2026.

Power mode VOLVO_POWER_MODE_MS_CAN

  • Service 22DID DD07
  • Module784
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−99
Range
-99 to 156
Unit
Number

In testing for 2023 to 2026.

Power mode VOLVO_POWER_MODE_MS_CAN_7E3

  • Service 22DID DD06
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Quiescent current average VOLVO_QUIESCENT_CURRENT

  • Service 22DID 4025
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767 mA
Unit
mA

In testing for 2023 to 2026.

Rear axle sensor VOLVO_REAR_AXLE_SENS

  • Service 22DID 3B73
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.37 V
Unit
V

In testing for 2023 to 2026.

Rear defroster automatic VOLVO_REAR_DEFROSTER

  • Service 22DID D918
  • Module733
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Rear left seat heater VOLVO_RL_SEAT_HEATER_MS

  • Service 22DID 9A23
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2023 to 2026.

Rear oxygen sensor heating VOLVO_REAR_OXYGEN_SENS

  • Service 22DID DB77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 ms
Unit
ms

In testing for 2023 to 2026.

Rear right seat heater VOLVO_RR_SEAT_HEATER_MS

  • Service 22DID 9A24
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2023 to 2026.

Recirculation damper motor wanted position VOLVO_RECIRCULATION_DAMPER

  • Service 22DID D901
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2023 to 2026.

Recirculation damper motor, actual position VOLVO_RECIRCULATION_DAMPER_ACT

  • Service 22DID D906
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2023 to 2026.

Remote key VOLVO_REMOTE_KEY

  • Service 22DID 412D
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Right seat heater VOLVO_RIGHT_SEAT_HEATER_MS

  • Service 22DID 9A22
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2023 to 2026.

Right temperature damper motor wanted position VOLVO_RIGHT_T_DAMPER_MOTOR

  • Service 22DID D903
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2023 to 2026.

Right temperature damper motor, actual position VOLVO_RIGHT_T_DAMPER_MOTOR_ACT

  • Service 22DID D908
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2023 to 2026.

Running time, hours VOLVO_RUNNING_TIME_HOURS

  • Service 22DID 9A0C
  • Module7E3
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2023 to 2026.

Running time, minutes VOLVO_RUNNING_TIME_MINUTES

  • Service 22DID 9A0C
  • Module7E3
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Seat buckle driver locked VOLVO_SEAT_BUCKLE_DRIVER

  • Service 22DID 5B19
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Number

In testing for 2023 to 2026.

Seat buckle passenger locked VOLVO_SEAT_BUCKLE

  • Service 22DID 5B1A
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Number

In testing for 2023 to 2026.

Seat buckle rear center locked VOLVO_SEAT_BUCKLE_REAR

  • Service 22DID 5B47
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Seat buckle rear left locked VOLVO_SEAT_BUCKLE_RL

  • Service 22DID 5B46
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Seat buckle rear right locked VOLVO_SEAT_BUCKLE_RR

  • Service 22DID 5B48
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Servo control module temperature VOLVO_SERVO_CTRL_MODULE_T

  • Service 22DID D11C
  • Module730
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Servo pump engine power consumption VOLVO_SERVO_PMP_ENG_POWER

  • Service 22DID 4139
  • Module730
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 A
Unit
A

In testing for 2023 to 2026.

Slave A/T VOLVO_SLAVE_T

  • Service 22DID 1E1B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2023 to 2026.

SLC1 current VOLVO_SLC1_CURRENT

  • Service 22DID D90C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

SLC2 current VOLVO_SLC2_CURRENT

  • Service 22DID D90F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

SLC3 current VOLVO_SLC3_CURRENT

  • Service 22DID D910
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Starter relay VOLVO_STARTER_RELAY

  • Service 22DID D950
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Starter relay 1 VOLVO_STARTER_RELAY_1

  • Service 22DID DA12
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Starter relay 2 VOLVO_STARTER_RELAY_2

  • Service 22DID EEEB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Steering angle, actual value VOLVO_STEER_ANG_ACT

  • Service 22DID 3302
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2023 to 2026.

Steering shaft torque VOLVO_STEER_SHFT_TQ

  • Service 22DID 330C
  • Module730
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−12.7
Range
-12.7 to 12.8 N·m
Unit
N·m

In testing for 2023 to 2026.

Supplementary heater counter VOLVO_SUPPLEMENTARY_HEATER

  • Service 22DID 9A0F
  • Module7E3
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

System relay VOLVO_SYSTEM_RELAY

  • Service 22DID D94F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Tailgate closing motor VOLVO_TAILGATE_CLOSING

  • Service 22DID D908
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Tailgate hall sensor signal VOLVO_TAILGATE_HALL_SENS

  • Service 22DID D904
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Tailgate handle button VOLVO_TAILGATE_HANDLE

  • Service 22DID D900
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Tailgate motor protection VOLVO_TAILGATE_MOTOR

  • Service 22DID EE04
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Tailgate opening motor VOLVO_TAILGATE_OPENING

  • Service 22DID D907
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Tailgate opening position VOLVO_TAILGATE_OPENING_POS

  • Service 22DID D909
  • Module775
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Tailgate power supply VOLVO_TAILGATE_POWER_SUP

  • Service 22DID D111
  • Module775
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Tailgate switch 1-2 VOLVO_TAILGATE_SWITCH_1_2

  • Service 22DID D901
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Temperature left setting VOLVO_T_LEFT_SETTING_MS

  • Service 22DID D930
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 °C
Unit
°C

In testing for 2023 to 2026.

Temperature right setting VOLVO_T_RIGHT_SETTING_MS

  • Service 22DID D931
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 °C
Unit
°C

In testing for 2023 to 2026.

Throttle absolute position VOLVO_THROTTLE_ABS_POS

Pelican can show this parameter as the throttle position.

  • Service 22DID F411
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Time since engine start VOLVO_TIME_SINCE_ENG_START

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2023 to 2026.

Torque converter lock-up solenoid VOLVO_LOCK_UP_SOLENOID_SLU_7E1

  • Service 22DID DA4C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Torque converter lock-up solenoid current VOLVO_LOCK_UP_SOLENOID_SLU_CURRENT

  • Service 22DID 1E47
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Torque converter lock-up solenoid current, requested VOLVO_LOCK_UP_SOLENOID_SLU

  • Service 22DID 1E41
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Torque converter lock-up solenoid, requested VOLVO_LOCK_UP_SOLENOID_SLU_REQ

  • Service 22DID DA4B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Torque from engine VOLVO_TQ_ENG

  • Service 22DID E501
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2023 to 2026.

Total engine running time at last service VOLVO_TOT_ENG_RUNNING_TIME

  • Service 22DID 61CC
  • Module720
  • Every30 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2023 to 2026.

Total months at last service VOLVO_TOT_MONTHS_LAST

  • Service 22DID 61CC
  • Module720
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val×6
Range
0 to 393210
Unit
Raw value

In testing for 2023 to 2026.

Traction control switch indicator VOLVO_DTSC_SWITCH

  • Service 22DID 2B05
  • Module760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val64−1
Range
-1 to 2.98
Unit
Number

In testing for 2023 to 2026.

Transmission fixed lock-up VOLVO_FIXED_LOCK_UP

  • Service 22DID 1E24
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Transmission kickdown VOLVO_KICKDOWN

  • Service 22DID DCE4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Transmission line pressure solenoid current VOLVO_LINEAR_P_SOLENOID_SLT

  • Service 22DID 1E40
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission line pressure solenoid current VOLVO_LINEAR_P_SOLENOID_SLT_CURRENT

  • Service 22DID DA4A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission line pressure solenoid current, requested VOLVO_LINEAR_P_SOLENOID

  • Service 22DID 1E1E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission line pressure solenoid current, requested VOLVO_LINEAR_P_SOLENOID_SLT_REQ

  • Service 22DID DA49
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SL1 current VOLVO_LINEAR_P_SOLENOID_SL1

  • Service 22DID DA4E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SL1, requested, current VOLVO_LINEAR_P_SOLENOID_SL1_REQ

  • Service 22DID DA4D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SL2 current VOLVO_LINEAR_P_SOLENOID_SL2

  • Service 22DID DA50
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SL2, requested, current VOLVO_LINEAR_P_SOLENOID_SL2_REQ

  • Service 22DID DA4F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SL3 current VOLVO_LINEAR_P_SOLENOID_SL3

  • Service 22DID DA52
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SL3, requested, current VOLVO_LINEAR_P_SOLENOID_SL3_REQ

  • Service 22DID DA51
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SLB1, requested, current VOLVO_LINEAR_P_SOLENOID_SLB1_REQ

  • Service 22DID 1E45
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SLC1 current VOLVO_LINEAR_P_SOLENOID_SLC1

  • Service 22DID 1E48
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SLC1, requested, current VOLVO_LINEAR_P_SOLENOID_SLC1_REQ

  • Service 22DID 1E42
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SLC2 current VOLVO_LINEAR_P_SOLENOID_SLC2

  • Service 22DID 1E49
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SLC2, requested, current VOLVO_LINEAR_P_SOLENOID_SLC2_REQ

  • Service 22DID 1E43
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SLC3 current VOLVO_LINEAR_P_SOLENOID_SLC3

  • Service 22DID 1E4A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission linear pressure solenoid SLC3, requested, current VOLVO_LINEAR_P_SOLENOID_SLC3_REQ

  • Service 22DID 1E44
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Transmission lock-up function VOLVO_LOCK_UP_FUNCTION

  • Service 22DID DA3C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val3−0.333333
Range
-0.333 to 84.66
Unit
Number

In testing for 2023 to 2026.

Transmission selector VOLVO_SELECTOR

  • Service 22DID DCEA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Number

In testing for 2023 to 2026.

Transmission solenoid S1 status VOLVO_SOLENOID_S1_STAT

  • Service 22DID DD89
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Transmission solenoid S2 status VOLVO_SOLENOID_S2_STAT

  • Service 22DID DD8A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Transmission start lock - start approved VOLVO_START_LOCK_START

  • Service 22DID DF08
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val255
Range
0 to 1
Unit
Number

In testing for 2023 to 2026.

Transmission torque VOLVO_TQ

  • Service 22DID DD8D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2023 to 2026.

Transmission torque limiting VOLVO_TQ_LIMITING

  • Service 22DID DCF0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 N·m
Unit
N·m

In testing for 2023 to 2026.

Trip 1 VOLVO_TRIP_1

  • Service 22DID D936
  • Module720
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km
Unit
km

In testing for 2023 to 2026.

Trip 2 VOLVO_TRIP_2

  • Service 22DID D937
  • Module720
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km
Unit
km

In testing for 2023 to 2026.

Turbo bypass valve opened VOLVO_TURBO_BYPASS_VLV

  • Service 22DID D9EE
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2023 to 2026.

Turbo control valve wastegate VOLVO_TURBO_CTRL_VLV_WASTEGATE

  • Service 22DID DC10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1008191
Range
0 to 800 %
Unit
%

In testing for 2023 to 2026.

Turbo control valve, bypass or variable nozzle VOLVO_TURBO_CTRL_VLV

  • Service 22DID DC00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1008191
Range
0 to 800 %
Unit
%

In testing for 2023 to 2026.

Twilight sensor VOLVO_TWILIGHT_SENS

  • Service 22DID 412A
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2023 to 2026.

Wastegate position VOLVO_WASTEGATE_POS

  • Service 22DID DC80
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Water cooled condenser outlet sensor temperature VOLVO_WATER_COOLED_T

  • Service 22DID EE40
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2023 to 2026.

Water temperature VOLVO_WATER_T_MS_CAN

  • Service 22DID F405
  • Module7E3
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Yaw rate sensor offset VOLVO_YAW_RATE_SENS_OFFSET

  • Service 22DID EE03
  • Module760
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val3500
Range
0 to 18.72
Unit
Raw value

In testing for 2023 to 2026.

Yaw rate signal VOLVO_YAW_RATE_SIG

  • Service 22DID 2B0B
  • Module760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553
Unit
Raw value

In testing for 2023 to 2026.

Fuel

Fuel filter heater VOLVO_FUEL_FLT_HEATER

  • Service 22DID DC14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Fuel filter heater VOLVO_FUEL_FLT_HEATER_7E0

  • Service 22DID DB35
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Fuel heater fan adjustment VOLVO_FUEL_HEATER_FAN_ADJ

  • Service 22DID 9A03
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2023 to 2026.

Fuel high pressure VOLVO_FUEL_HIGH_P

  • Service 22DID EE4F
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.76
Unit
Raw value

In testing for 2023 to 2026.

Fuel level 1 of 2 VOLVO_DIM_FLI_1_2

  • Service 22DID 61D1
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 L
Unit
L

In testing for 2023 to 2026.

Fuel level 2 of 2 ejector side saddle tank VOLVO_DIM_FLI_2_2_EJECTOR

  • Service 22DID 61D0
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 L
Unit
L

In testing for 2023 to 2026.

Fuel level damped VOLVO_DIM_FLI_DAMPED

  • Service 22DID EE11
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 L
Unit
L

In testing for 2023 to 2026.

Fuel level damped VOLVO_FLI_DAMPED

  • Service 22DID EE12
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 L
Unit
L

In testing for 2023 to 2026.

Fuel level input VOLVO_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Fuel level sensor VOLVO_FLI_SENS

  • Service 22DID 4117
  • Module726
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10020459
Range
0 to 320 V
Unit
V

In testing for 2023 to 2026.

Fuel level sensor ejector side saddle tank VOLVO_FLI_SENS_EJECTOR

  • Service 22DID 4118
  • Module726
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10020459
Range
0 to 320 V
Unit
V

In testing for 2023 to 2026.

Fuel low pressure VOLVO_FUEL_LOW_P

  • Service 22DID EE57
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2023 to 2026.

Fuel pressure VOLVO_FUEL_P

  • Service 22DID F423
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100
Range
0 to 6553500
Unit
Raw value

In testing for 2023 to 2026.

Fuel pressure VOLVO_FUEL_P_DA10

  • Service 22DID F40A
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2023 to 2026.

Fuel pressure nominal value VOLVO_FUEL_P_NOMINAL

  • Service 22DID D9FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100
Range
0 to 6553500
Unit
Raw value

In testing for 2023 to 2026.

Fuel pressure regulator valve current VOLVO_FUEL_P_REGULATOR_VLV

  • Service 22DID D9EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2023 to 2026.

Fuel pump low pressure side duty cycle VOLVO_FUEL_PMP_LOW_P_SIDE

  • Service 22DID EF59
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2023 to 2026.

Fuel temperature VOLVO_FUEL_T

  • Service 22DID D99C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273
Range
-3549 to 3003 °C
Unit
°C

In testing for 2023 to 2026.

Fuel volume control valve VOLVO_FUEL_VOLUME_CTRL_VLV

  • Service 22DID DAD5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2023 to 2026.

Fuel volume control valve VOLVO_FUEL_VOLUME_CTRL_VLV_7E0

  • Service 22DID DC13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2023 to 2026.

Lights

Brake light switch VOLVO_BRAKE_LIGHT_SWITCH

  • Service 22DID 2B00
  • Module760
  • Every250 ms
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2023 to 2026.

Movement

Accelerator pedal position VOLVO_ACCEL_PEDAL_POS

  • Service 22DID DD8E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2023 to 2026.

Adaptive cruise set speed VOLVO_ACC_SETSPEED

  • Service 22DID DA10
  • Module720
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Air conditioning compressor module a speed VOLVO_AC_COMP_MODULE_SPD

  • Service 22DID 032F
  • ModuleD016 → 1EC04E80
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2023 to 2026.

Cabin fan speed, requested VOLVO_CABIN_FAN_SPD_REQ_MS

  • Service 22DID D950
  • Module733
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 %
Unit
%

In testing for 2023 to 2026.

Driven shaft speed VOLVO_DRIVEN_SHFT_SPD

  • Service 22DID DA38
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2023 to 2026.

Electric rear axle drive motor speed VOLVO_ERAD_MOTOR_SPD

  • Service 22DID 4A0E
  • ModuleD016 → 1EC6EE80
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 rpm
Unit
rpm

In testing for 2023 to 2026.

Indirect tire pressure monitoring high speed calibration VOLVO_ITPMS_HIGH_SPD

  • Service 22DID FDC6
  • Module760
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2023 to 2026.

Indirect tire pressure monitoring low speed calibration VOLVO_ITPMS_LOW_SPD

  • Service 22DID FDC6
  • Module760
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2023 to 2026.

Lateral acceleration sensor offset VOLVO_LATERAL

  • Service 22DID EE03
  • Module760
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val113000
Range
0 to 0.579 m/s²
Unit
m/s²

In testing for 2023 to 2026.

Lateral acceleration sensor stored offset VOLVO_LATERAL_ACCELEROMETER

  • Service 22DID EE04
  • Module760
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1113000
Range
0 to 0.0588 m/s²
Unit
m/s²

In testing for 2023 to 2026.

Radiator cooling fan 1, requested speed VOLVO_RADIATOR_COOLING_FAN_1

  • Service 22DID EE62
  • ModuleD016 → 1EC60E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2023 to 2026.

Servo pump speed VOLVO_SERVO_PMP_SPD

  • Service 22DID 413C
  • Module730
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100 rpm
Unit
rpm

In testing for 2023 to 2026.

Servo pump speed, desired value VOLVO_SERVO_PMP_SPD_DES

  • Service 22DID 413A
  • Module730
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100 rpm
Unit
rpm

In testing for 2023 to 2026.

Traffic sign speed limit VOLVO_TSI_SPD

  • Service 22DID DA18
  • Module720
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×5
Range
0 to 327675 km/h
Unit
km/h

In testing for 2023 to 2026.

Vehicle speed VOLVO_VSS

  • Service 22DID F40D
  • ModuleD016 → 1EC6EE80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Stats

Battery heater operating time VOLVO_ED_HEATER_HOURS

  • Service 22DID 6321
  • Module7E5 → 7ED
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2023 to 2026.

Coolant pump operating time VOLVO_ED_PUMP_HOURS

  • Service 22DID 6309
  • Module7E5 → 7ED
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2023 to 2026.

Cooling fan operating time VOLVO_ED_FAN_HOURS

  • Service 22DID 630A
  • Module7E5 → 7ED
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2023 to 2026.

Tires

Front left wheel speed VOLVO_FL_WHL_SPD

  • Service 22DID 2B06
  • ModuleD016 → 1EC62E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Front left wheel speed VOLVO_FL_WHL_SPD_760

  • Service 22DID 2B06
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Front left wheel speed VOLVO_FL_WHL_SPD_795

  • Service 22DID 2B06
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Front left wheel speed VOLVO_FL_WHL_SPD_V2

  • Service 22DID 2B06
  • ModuleD016 → 1EC02E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Front right wheel speed VOLVO_FR_WHL_SPD

  • Service 22DID 2B07
  • ModuleD016 → 1EC62E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Front right wheel speed VOLVO_FR_WHL_SPD_760

  • Service 22DID 2B07
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Front right wheel speed VOLVO_FR_WHL_SPD_795

  • Service 22DID 2B07
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Front right wheel speed VOLVO_FR_WHL_SPD_V2

  • Service 22DID 2B07
  • ModuleD016 → 1EC02E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Rear left wheel speed VOLVO_RL_WHL_SPD

  • Service 22DID 2B08
  • ModuleD016 → 1EC62E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Rear left wheel speed VOLVO_RL_WHL_SPD_760

  • Service 22DID 2B08
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Rear left wheel speed VOLVO_RL_WHL_SPD_795

  • Service 22DID 2B08
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Rear left wheel speed VOLVO_RL_WHL_SPD_V2

  • Service 22DID 2B08
  • ModuleD016 → 1EC02E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Rear right wheel speed VOLVO_RR_WHL_SPD

  • Service 22DID 2B09
  • ModuleD016 → 1EC62E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Rear right wheel speed VOLVO_RR_WHL_SPD_760

  • Service 22DID 2B09
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Rear right wheel speed VOLVO_RR_WHL_SPD_795

  • Service 22DID 2B09
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Rear right wheel speed VOLVO_RR_WHL_SPD_V2

  • Service 22DID 2B09
  • ModuleD016 → 1EC02E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2023 to 2026.

Steering wheel angle sensor offset VOLVO_SAS_STEER_WHL_ANG

  • Service 22DID EE03
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val22.8533
Range
-1433 to 1433 °
Unit
°

In testing for 2023 to 2026.

Steering wheel angle sensor stored offset VOLVO_SAS_STEER_WHL_ANG_SENS

  • Service 22DID EE04
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1461
Range
-22.42 to 22.42 °
Unit
°

In testing for 2023 to 2026.

Steering wheel angle velocity VOLVO_STEER_WHL_ANG

  • Service 22DID 3301
  • Module730
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020
Unit
Raw value

In testing for 2023 to 2026.

Tire sensor 1 battery low VOLVO_TPMS_LOWBAT_1

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2023 to 2026.

Tire sensor 1 missing VOLVO_TPMS_MISSING_1

  • Service 21PID 79
  • Module745 → 765
  • Every60 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2023 to 2026.

Tire sensor 1 pressure VOLVO_TP_1

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×0.75
Range
0 to 49151.25 kPa
Unit
kPa

In testing for 2023 to 2026.

Tire sensor 1 temperature VOLVO_TT_1

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val−30
Range
-30 to 225 °C
Unit
°C

In testing for 2023 to 2026.

Tire sensor 2 battery low VOLVO_TPMS_LOWBAT_2

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bit 174 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2023 to 2026.

Tire sensor 2 missing VOLVO_TPMS_MISSING_2

  • Service 21PID 79
  • Module745 → 765
  • Every60 s
  • Testing

Bit 206 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2023 to 2026.

Tire sensor 2 pressure VOLVO_TP_2

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×0.75
Range
0 to 49151.25 kPa
Unit
kPa

In testing for 2023 to 2026.

Tire sensor 2 temperature VOLVO_TT_2

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val−30
Range
-30 to 225 °C
Unit
°C

In testing for 2023 to 2026.

Tire sensor 3 battery low VOLVO_TPMS_LOWBAT_3

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bit 173 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2023 to 2026.

Tire sensor 3 missing VOLVO_TPMS_MISSING_3

  • Service 21PID 79
  • Module745 → 765
  • Every60 s
  • Testing

Bit 205 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2023 to 2026.

Tire sensor 3 pressure VOLVO_TP_3

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val×0.75
Range
0 to 49151.25 kPa
Unit
kPa

In testing for 2023 to 2026.

Tire sensor 3 temperature VOLVO_TT_3

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val−30
Range
-30 to 225 °C
Unit
°C

In testing for 2023 to 2026.

Tire sensor 4 battery low VOLVO_TPMS_LOWBAT_4

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bit 172 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2023 to 2026.

Tire sensor 4 missing VOLVO_TPMS_MISSING_4

  • Service 21PID 79
  • Module745 → 765
  • Every60 s
  • Testing

Bit 204 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2023 to 2026.

Tire sensor 4 pressure VOLVO_TP_4

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val×0.75
Range
0 to 49151.25 kPa
Unit
kPa

In testing for 2023 to 2026.

Tire sensor 4 temperature VOLVO_TT_4

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val−30
Range
-30 to 225 °C
Unit
°C

In testing for 2023 to 2026.

Transmission

A/T converter VOLVO_T_CONV

  • Service 22DID 1E14
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2023 to 2026.

AT, actual gear ratio VOLVO_ACT_GEAR_RAT

  • Service 22DID 1E16
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.99
Unit
Number

In testing for 2023 to 2026.

Clutch 1 temperature VOLVO_CLU_1_T

  • Service 22DID D926
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2023 to 2026.

Clutch 2 temperature VOLVO_CLU_2_T

  • Service 22DID D940
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2023 to 2026.

Clutch actuator 1 temperature VOLVO_CLU_ACTUATOR_1_T

  • Service 22DID D96B
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2023 to 2026.

Clutch actuator 2 temperature VOLVO_CLU_ACTUATOR_2_T

  • Service 22DID D974
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2023 to 2026.

Clutch pump duty VOLVO_CLU_PMP_DUTY

  • Service 22DID D920
  • ModuleD016 → 1EC70E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2023 to 2026.

Gear VOLVO_GEAR

  • Service 22DID DA85
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Gear ratio expected VOLVO_GEAR_RAT_EXPECTED

  • Service 22DID DA47
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2023 to 2026.

Gear ratio, actual VOLVO_GEAR_RAT_ACT

  • Service 22DID DA34
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×61250000
Range
0 to 15.99
Unit
Number

In testing for 2023 to 2026.

Gear ratio, actual VOLVO_GEAR_RAT_ACT_7E1

  • Service 22DID DA34
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.99
Unit
Number

In testing for 2023 to 2026.

Gear ratio, requested VOLVO_GEAR_RAT_REQ

  • Service 22DID DA47
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2023 to 2026.

Gear, AT position VOLVO_GEAR_POS

  • Service 22DID DA40
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2023 to 2026.

Torque converter lock VOLVO_TQ_CONV_LOCK

  • Service 22DID DA3C
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Transmission expected gear ratio VOLVO_EXPECTED_GEAR_RAT

  • Service 22DID 1E19
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2023 to 2026.

Transmission fluid temperature VOLVO_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID DA3B
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2023 to 2026.

Transmission fluid temperature VOLVO_ATF_T_1E3F

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E3F
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2023 to 2026.

Transmission fluid temperature VOLVO_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E3F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 °C
Unit
°C

In testing for 2023 to 2026.

Transmission fluid temperature VOLVO_ATF_T_D016

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID D900
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1000
Range
-32768000 to 32767000 °C
Unit
°C

In testing for 2023 to 2026.

Transmission fluid temperature VOLVO_ATF_T_D016_D016

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID D90D
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 °C
Unit
°C

In testing for 2023 to 2026.

Transmission fluid temperature VOLVO_ATF_T_DA18

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID E004
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2023 to 2026.

Transmission fluid temperature, variant 2 VOLVO_ATF_T_VAR_2

  • Service 22DID D904
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2023 to 2026.

Transmission fluid temperature, variant 2 VOLVO_ATF_T_VAR_2_7E1

  • Service 22DID DA3B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2023 to 2026.

Transmission fluid temperature, variant 3 VOLVO_ATF_T_VAR_3

  • Service 22DID D9A1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2023 to 2026.

Transmission gear VOLVO_GEAR_7E1

  • Service 22DID DD81
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Transmission gear selector p, 0 r, 1 n, 2 d, 3 VOLVO_GEAR_SELECTOR_P_0_R_1_N_2_D_3

  • Service 22DID 6310
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Trips

All-wheel drive coupling distance VOLVO_HALDEX_DIST

  • Service 22DID DD01
  • Module795
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Distance at trip start VOLVO_TRIP_START_DIST

  • Service 22DID 01A0
  • Module743 → 763
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2023 to 2026.

Distance since last service VOLVO_DIST_SINCE_SERVICE

  • Service 22DID D903
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2023 to 2026.

Distance since last service VOLVO_DIST_SINCE_SERVICE_720

  • Service 22DID 630E
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2023 to 2026.

Distance to empty VOLVO_DIST_EMPTY_MS_CAN

Pelican can show this parameter as the fuel range.

  • Service 22DID EEFD
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2023 to 2026.

Distance, battery controller VOLVO_BMS_ODO

  • Service 21PID 61
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2023 to 2026.

Front left distance VOLVO_FL_DIST

  • Service 22DID B116
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2023 to 2026.

Front left inner distance VOLVO_FL_INNER_DIST

  • Service 22DID B118
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2023 to 2026.

Front right distance VOLVO_FR_DIST

  • Service 22DID B117
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2023 to 2026.

Front right inner distance VOLVO_FR_INNER_DIST

  • Service 22DID B119
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2023 to 2026.

HV battery remaining distance VOLVO_EQA_HV_RANGE

Pelican can show this parameter as the electric range.

  • Service 22DID 6502
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_MILEAGE_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • ModuleD016 → 1EC64E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_BCM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module760
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_CEM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_CVM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module793
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_DDM_MS_CAN

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module740
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_DIM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module720
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_FSM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module764
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_PAM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module736
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_PBM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module756
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_PDM_MS_CAN

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module741
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_PPM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module794
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_PSCM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module730
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_SAS

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module797
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_SRS

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module737
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_TCM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer VOLVO_ODO_V2

Pelican can show this parameter as the odometer.

  • Service 22DID 61BB
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer at last service VOLVO_ODO_LAST_SERVICE

  • Service 22DID D906
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer at last service VOLVO_ODO_LAST_SERVICE_720

  • Service 22DID 61CC
  • Module720
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Primary, target range, m VOLVO_PRIMARY_TGT_RANGE_M

  • Service 22DID A223
  • Module764
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2023 to 2026.

Rear left distance VOLVO_RL_DIST

  • Service 22DID B112
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2023 to 2026.

Rear left inner distance VOLVO_RL_INNER_DIST

  • Service 22DID B114
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2023 to 2026.

Rear right distance VOLVO_RR_DIST

  • Service 22DID B113
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2023 to 2026.

Rear right inner distance VOLVO_RR_INNER_DIST

  • Service 22DID B115
  • Module736
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2023 to 2026.

Time at trip start VOLVO_TRIP_START_TIME

  • Service 22DID 01A2
  • Module743 → 763
  • Every60 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 s
Unit
s

In testing for 2023 to 2026.

Total distance VOLVO_DEM_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • ModuleD016 → 1EC70E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Total distance VOLVO_TOT_DIST

  • Service 22DID DD01
  • ModuleD016 → 1EC6EE80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Trip time VOLVO_TRIP_TIME

  • Service 22DID 2104
  • Module743 → 763
  • Every60 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 s
Unit
s

In testing for 2023 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.