Volkswagen Virtus

Parameters

The Volkswagen Virtus has 1,174 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Control module voltage VIRTUS_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x2F6C = 12140 → 121401000 = 12.14 V

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery capacity VIRTUS_12V_BAT_CAP

  • Service 22DID 2A06
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2018 to 2026.

12V battery temperature VIRTUS_BAT_SENSOR_T

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Accelerator pedal, sensor 1 voltage VIRTUS_ACCEL_PEDAL_SENS_1_V

  • Service 22DID 102A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2018 to 2026.

Accelerator pedal, sensor 2 voltage VIRTUS_ACCEL_PEDAL_SENS_2_V

  • Service 22DID 102B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2018 to 2026.

Aux. hydraulic pump voltage VIRTUS_AUX_HYDRAULIC_PMP_V

  • Service 22DID 51A7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2018 to 2026.

Battery acid stratification VIRTUS_BAT_ACID

  • Service 22DID 2A1D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10+9
Range
0 to 2559 %
Unit
%

In testing for 2018 to 2026.

Battery charge level VIRTUS_BAT_SOCConfirmed

  • Service 22DID 2A0C
  • Module710 → 77A
  • Every10 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x45 = 69 → 69 %

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Battery condition for display VIRTUS_BAT_COND_DISPLAY

  • Service 22DID 2A0D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 %
Unit
%

In testing for 2018 to 2026.

Battery current VIRTUS_BAT_IConfirmed

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-1000 to 1000 A
Unit
A

0x00000A70 = 2672 → 26721000 = 2.672 A

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Battery current filtered VIRTUS_BAT_CURRENT_FILTERED

  • Service 22DID 2A08
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val1000−3000
Range
-3000 to 13777 A
Unit
A

In testing for 2018 to 2026.

Battery internal resistance VIRTUS_BAT_INT_RConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20100
Range
0 to 51
Unit
Raw value

0x22 = 34 → 34×20100 = 6.8

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Battery internal resistance, raw VIRTUS_BAT_INTERNAL_RES_RAW

  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51
Unit
Raw value

In testing for 2018 to 2026.

Battery temperature VIRTUS_BAT_TConfirmed

  • Service 22DID 2A0B
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x49 = 73 → 73−40 = 33 °C

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Battery voltage VIRTUS_BAT_V

  • Service 22DID 105A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2018 to 2026.

Battery voltage VIRTUS_BAT_V_2A07Confirmed

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x20C5 = 8389 → 83891000+4 = 12.389 V

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Battery voltage at rest VIRTUS_BAT_V_AT_RESTConfirmed

  • Service 22DID 2A10
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+9
Range
9 to 34.5 V
Unit
V

0x22 = 34 → 3410+9 = 12.4 V

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Battery voltage variant VIRTUS_PQ35_BAT_V_2

  • Service 22DID 105E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2018 to 2026.

Boost pressure VIRTUS_PQ35_CHG_P

  • Service 22DID 1057
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2018 to 2026.

Bypass valve high pressure turbine inlet, raw voltage VIRTUS_BYPASS_VLV_HIGH_P_V

  • Service 22DID 3D01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2018 to 2026.

Calculated nitrogen oxide concentration behind turbocharger VIRTUS_MQB_NOX_CONC_BEHIND_TURBO

  • Service 22DID 1526
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2018 to 2026.

Charge adjuster output stage VIRTUS_HIGH_P_TURBOCHARGER

  • Service 22DID 1181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2018 to 2026.

Charge air cooler inlet, pressure sensor 1 bank 1 raw value VIRTUS_CHG_AIR_COOLER_INLET_P_1_1

  • Service 22DID 445A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Raw value

In testing for 2018 to 2026.

Charge air pressure actuator position digit.value VIRTUS_CHG_AIR_P_ACTUATOR_7E0

  • Service 22DID 1B11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Charge air pressure, actual value VIRTUS_AIR_P_CAC_DS

  • Service 22DID 1056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Charge air pressure, actual value VIRTUS_CHG_AIR_P_ACT

  • Service 22DID 1B0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119
Unit
Raw value

In testing for 2018 to 2026.

Charge air pressure, specified value VIRTUS_CHG_AIR_P_SPEC

  • Service 22DID FE47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2018 to 2026.

Charge air pressure: actual VIRTUS_PQ35_CHARGE_AIR_P_ACTUAL

  • Service 22DID 202A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08
Range
0 to 5242.8
Unit
Raw value

In testing for 2018 to 2026.

Charge air pressure: specified VIRTUS_PQ35_CHARGE_AIR_P_SPECIFIED

  • Service 22DID 2029
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08
Range
0 to 5242.8
Unit
Raw value

In testing for 2018 to 2026.

Charge air temp at the turbocharger outlet, calculated VIRTUS_MQB_CHARGE_AIR_T_TUBROCHARGER_OUTLET_CALCULATED

  • Service 22DID 1798
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000−273.1
Range
-273.1 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Charge limit overcharge protection VIRTUS_PQ35_CHG_LIM_OVER

  • Service 22DID 1356
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2026.

Charge pressure actuator, acknowledgment VIRTUS_CHG_P_ACTUATOR

  • Service 22DID 2065
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Charge pressure actuator, actual position VIRTUS_CHG_P_ACTUATOR_ACT

  • Service 22DID 39A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure actuator, adaptation for lower stop VIRTUS_CHG_P_ACTUATOR_ADPT

  • Service 22DID 39A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2018 to 2026.

Charge pressure actuator, adaptation for upper stop VIRTUS_CHG_P_ACTUATOR_ADPT_HI

  • Service 22DID 39A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2018 to 2026.

Charge pressure actuator, maximum sensor voltage VIRTUS_CHG_P_ACTUATOR_MAX_V

  • Service 22DID 3D77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 mV
Unit
mV

In testing for 2018 to 2026.

Charge pressure actuator, specified position VIRTUS_CHG_P_ACTUATOR_SPEC

  • Service 22DID 39A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2018 to 2026.

Charge pressure actuator, specified value VIRTUS_CHG_P_ACTUATOR_SPEC_7E0

  • Service 22DID 39A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure before throttle valve, calculated actual value VIRTUS_CHG_P_BEFORE_ACT

  • Service 22DID 432B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191
Unit
Raw value

In testing for 2018 to 2026.

Charge pressure control specified value VIRTUS_CHG_P_CTRL_SPEC

  • Service 22DID 1108
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure control valve activation pulse duty factor VIRTUS_CHG_P_CTRL_VLV

  • Service 22DID 3EA9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure control valve position, actual value VIRTUS_CHG_P_CTRL_VLV_POS_ACT

  • Service 22DID 3EA7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure control valve position, target value VIRTUS_CHG_P_CTRL_VLV_POS_TGT

  • Service 22DID 3EA6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure control valve sensor voltage VIRTUS_CHG_P_CTRL_VLV_SENS_V

  • Service 22DID 3EA8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2018 to 2026.

Charge pressure control valve voltage, position closed VIRTUS_CHG_P_CTRL_VLV_V_POS

  • Service 22DID 3EAB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2018 to 2026.

Charge pressure control valve voltage, position opened VIRTUS_CHG_P_CTRL_VLV_V_POS_OPENED

  • Service 22DID 3EAC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2018 to 2026.

Charge pressure control, adapt. higher than max. threshold VIRTUS_CHG_P_CTRL_ADAPT_MAX

  • Service 22DID 293E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure control, adapt. lower than min. threshold VIRTUS_CHG_P_CTRL_ADAPT_LO_MIN

  • Service 22DID 293F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure regulator, lower threshold adaptation VIRTUS_CHG_P_REGULATOR_LO

  • Service 22DID 16EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2018 to 2026.

Charge pressure regulator, upper threshold adaptation VIRTUS_CHG_P_REGULATOR_HI

  • Service 22DID 16ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2018 to 2026.

Charge pressure sensor, unconditioned voltage VIRTUS_CHG_P_SENS_V

  • Service 22DID 29C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Control module voltage VIRTUS_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x2F6C = 12140 → 121401000 = 12.14 V

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Cylinder charge specified value VIRTUS_CYL_CHG_SPEC

  • Service 22DID 432F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2018 to 2026.

Cylinder charge, actual value VIRTUS_CYL_CHG_ACT

  • Service 22DID 4367
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2018 to 2026.

Electric machine high-voltage battery energy information VIRTUS_HIGH_V_EM_HVBAT

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 kWh
Unit
kWh

In testing for 2018 to 2026.

Exhaust gas recirculation valve 1, B1, mass current: specified value VIRTUS_MQB_EGR_VALVE_1_B1_MASS_I_SPEC

  • Service 22DID 1813
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2018 to 2026.

Exhaust gas recirculation valve 2, B1, mass current: specified value VIRTUS_MQB_EGR_VALVE_2_B1_MASS_I_SPEC

  • Service 22DID 1814
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2018 to 2026.

Generator voltage, actual VIRTUS_GEN_V_ACT

  • Service 22DID 4F00
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

In testing for 2018 to 2026.

High pressure exhaust gas recirculation actuator, actual unconditioned voltage VIRTUS_HIGH_P_EGR_ACTUATOR_ACT_V

  • Service 22DID 11A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2018 to 2026.

High voltage battery energy information VIRTUS_HVBAT_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638 kWh
Unit
kWh

In testing for 2018 to 2026.

Ignition angle current cylinder VIRTUS_PQ35_IGN_ANG_CYL

  • Service 22DID 137A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−35.625
Range
-35.625 to 60 N·m
Unit
N·m

In testing for 2018 to 2026.

Knock sensor voltage, cylinder 1 VIRTUS_KNOCK_SENS_V_CYL_1

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2018 to 2026.

Knock sensor voltage, cylinder 3 VIRTUS_KNOCK_SENS_V_CYL_3_7E0

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2018 to 2026.

Knock sensor voltage:, cylinder 2 VIRTUS_KNOCK_SENS_V_CYL_2

  • Service 22DID 13FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2018 to 2026.

Knock sensor voltage:, cylinder 3 VIRTUS_KNOCK_SENS_V_CYL_3

  • Service 22DID 13FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2018 to 2026.

Knock sensor voltage:, cylinder 5 VIRTUS_KNOCK_SENS_V_CYL_5

  • Service 22DID 13FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2018 to 2026.

Knock sensors average voltage bank 1,, variant 2 VIRTUS_KNOCK_SENSORS_AVG_V_1_2

  • Service 22DID 4E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Maximum charge current VIRTUS_MAX_CHA_CUR_2

  • Service 22DID 1159
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Maximum discharge current VIRTUS_MAX_DCHA_CUR_2

  • Service 22DID 1158
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Start/stop battery target voltage VIRTUS_SSB_VTConfirmed

  • Service 22DID 2A00
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

0x26 = 38 → 3810+10.6 = 14.4 V

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Start/stop battery total charge VIRTUS_SSB_TOTAL_CHARGEConfirmed

  • Service 22DID 2A61
  • Module710 → 77A
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

0x0000CB69 = 52073 → 5207310 = 5,207.3 Ah

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Start/stop battery total discharge VIRTUS_SSB_TOTAL_DISCHARGEConfirmed

  • Service 22DID 2A61
  • Module710 → 77A
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

0x0000C50D = 50445 → 5044510 = 5,044.5 Ah

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Temperature sensor for engine temperature management voltage VIRTUS_T_SENS_ENG_T_V

  • Service 22DID 40E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Turbocharger inlet pressure corrected value VIRTUS_TURBOCHARGER_INLET_P

  • Service 22DID 11D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.078125
Range
0 to 5119
Unit
Raw value

In testing for 2018 to 2026.

Usable battery charge VIRTUS_USE_BAT_CHGConfirmed

  • Service 22DID 2A0F
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

0x1D = 29 → 29 Ah

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Climate

A/C compressor torque, requested VIRTUS_AC_COMP_TConfirmed

  • Service 22DID 1002
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

0x0000 = 0 → 010 = 0 N·m

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Air conditioning compressor shutdown requirement VIRTUS_MQB_TCM_A_C_COMPRESSOR_SHUTDOWN_REQUIREMENT

  • Service 22DID 381A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Air conditioning compressor torque VIRTUS_PQ35_AC_COMP_TRQ

  • Service 22DID 104B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Ambient air temperature VIRTUS_AAT_7E0_7E0

  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2026.

Ambient temperature VIRTUS_AAT_V2Confirmed

  • Service 22DID 1004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-255 to 255 °C
Unit
°C

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Barometric pressure VIRTUS_BARO

  • Service 22DID F433
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2018 to 2026.

Outside temperature VIRTUS_AAT_746Confirmed

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x9A = 154 → 1542−50 = 27 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Recirculation flap actual position VIRTUS_MQB_RECIRC_FLAP_ACTConfirmed

  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0xC8 = 200 → 2002 = 100 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Recirculation flap fresh air threshold VIRTUS_MQB_RECIRC_FLAP_FRESH_THRConfirmed

  • Service 22DID 2620
  • Module746 → 7B0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x004C = 76 → 76

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Recirculation flap target position VIRTUS_MQB_RECIRC_FLAP_TRGConfirmed

  • Service 22DID 261F
  • Module746 → 7B0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0047 = 71 → 71

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Recirculation flap threshold VIRTUS_MQB_RECIRC_FLAP_THRConfirmed

  • Service 22DID 2621
  • Module746 → 7B0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x00C6 = 198 → 198

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Windshield temperature VIRTUS_WNDSHLD_TEMP

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.576−38.8
Range
-38.8 to 108.08 °C
Unit
°C

In testing for 2018 to 2023, 2025 to 2026. Not supported for 2024.

Clocks

Time since engine start VIRTUS_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x00D4 = 212 → 212 s

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Control

Accelerator pedal release detection threshold voltage VIRTUS_APP_REDUCE_V

  • Service 22DID 1029
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2018 to 2026.

Air gab vacuum sensor VIRTUS_AIR_GAB_VACUUM_SNSConfirmed

  • Service 22DID 1816
  • Module713 → 77D
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val
Range
0 to 32767
Unit
Raw value

0x003C = 60 → 60

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Brake booster pressure VIRTUS_BRAKE_BOOSTER_P

  • Service 22DID 11CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×19531500000
Range
0 to 2559
Unit
Raw value

In testing for 2018 to 2026.

Brake booster raw pressure VIRTUS_BRAKE_BOOSTER_RAW_P

  • Service 22DID 11D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Brake booster, actual vacuum VIRTUS_BRAKE_BOOSTER_ACT

  • Service 22DID 1490
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×390.6210000
Range
-1279 to 1279
Unit
Raw value

In testing for 2018 to 2026.

Brake disk drying VIRTUS_BDD_ACTIVEConfirmed

  • Service 22DID 180E
  • Module713 → 77D
  • Every2 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Brake disk drying, odometer at last activation VIRTUS_BDD_ODOConfirmed

  • Service 22DID 180E
  • Module713 → 77D
  • Every2 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x0051A0 = 20896 → 20,896 km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Brake pedal position VIRTUS_BRAKE_PEDAL_POS

  • Service 22DID 105D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122.0710000
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Brake pressure VIRTUS_BRAKE_P

  • Service 22DID 105C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2018 to 2026.

Brake pressure VIRTUS_BRAKE_P_713

  • Service 22DID 2B21
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×15299910000000−42.503
Range
-543.8501 to 458.8288 bar
Unit
bar

In testing for 2018 to 2026.

Brake pressure VIRTUS_BRAKE_P_7E0

  • Service 22DID 195D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2018 to 2026.

Brake pressure VIRTUS_MQB_TCM_BRAKE_P

  • Service 22DID 3803
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Brake pressure VIRTUS_PQ35_BRAKE_P

  • Service 22DID 18D0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2026.

Brake pressure sensor VIRTUS_BRAKE_P_SNSConfirmed

  • Service 22DID 1816
  • Module713 → 77D
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 327.67 bar
Unit
bar

0x1081 = 4225 → 4225100 = 42.25 bar

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Brake system vacuum pump active VIRTUS_BRAKE_SYSTEM_VACUUM

  • Service 22DID 395E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Downshift point adaptation voltage VIRTUS_DOWNSHIFT_ADAPT_V

  • Service 22DID 1028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2018 to 2026.

Electronic differential lock: active VIRTUS_EDL_ACTIVEConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Electronic differential lock: front left brake temperature VIRTUS_EDL_FR_L_BRAKE_TConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Electronic differential lock: front right brake temperature VIRTUS_EDL_FR_R_BRAKE_TConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Electronic differential lock: rear left brake temperature VIRTUS_EDL_RR_L_BRAKE_TConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Electronic differential lock: rear right brake temperature VIRTUS_EDL_RR_R_BRAKE_TConfirmed

  • Service 22DID 180C
  • Module713 → 77D
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-20 to 300 °C
Unit
°C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Hydraulic brake booster: active VIRTUS_HYD_BRAKE_BOOST_ACTIVEConfirmed

  • Service 22DID 1810
  • Module713 → 77D
  • Every2 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Pressure in brake servo unit VIRTUS_P_BRAKE_SERVO_UNIT

  • Service 22DID 2005
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375
Unit
Raw value

In testing for 2018 to 2026.

Requested brake torque, auxiliary system VIRTUS_REQ_BRAKE_TQ

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2018 to 2026.

Drivetrain

Driver torque requested #1 VIRTUS_ENG_TRQ_REQ_1

  • Service 22DID 29D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Driver torque requested #2 VIRTUS_ENG_TRQ_REQ_2

  • Service 22DID 4380
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2024.

Distance traveled since diagnostic trouble codes cleared VIRTUS_CLR_DISTConfirmed

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x733D = 29501 → 29,501 km

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Distance traveled while mil was activated VIRTUS_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Number of warm-ups since diagnostic trouble codes cleared VIRTUS_WARM_UPSConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFF = 255 → 255

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

ECU

Misfires, cylinder 2 VIRTUS_MISFIRES__CYL__2Confirmed

  • Service 22DID 1152
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x08FB = 2299 → 2,299

Confirmed for 2024. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022.

Misfires, cylinder 4 VIRTUS_MISFIRES__CYL__4Confirmed

  • Service 22DID 1151
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0B63 = 2915 → 2,915

Confirmed for 2024. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022.

Torque converter slip VIRTUS_TORQUE_CONVERTER_SLIP

  • Service 22DID 2131
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2018 to 2026.

Engine

A/C compressor load VIRTUS_CLIMATE_A_C_COMP_LOADConfirmed

  • Service 22DID 2604
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 N·m
Unit
N·m

0x62 = 98 → 9810 = 9.8 N·m

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Actual turbo boost VIRTUS_ACT_TURBO_BOOST

  • Service 22DID 11F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2 bar
Unit
bar

In testing for 2018 to 2026.

Adaptation of loss torque VIRTUS_ADPT_LOSS_TQ

  • Service 22DID 2929
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2018 to 2026.

Adaptation of throttle valve VIRTUS_ADPT_THROTTLE_VLV

  • Service 22DID 292B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Adaptation val.cylinder1 fast diagnosis VIRTUS_ADPT_VAL_CYL1_FAST

  • Service 22DID 3F45
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2018 to 2026.

Adaptation val.cylinder1 slow diagnosis VIRTUS_ADPT_VAL_CYL1_SLOW

  • Service 22DID 3F41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2018 to 2026.

Adaptation val.cylinder2 fast diagnosis VIRTUS_ADPT_VAL_CYL2_FAST

  • Service 22DID 3F48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2018 to 2026.

Adaptation val.cylinder2 slow diagnosis VIRTUS_ADPT_VAL_CYL2_SLOW

  • Service 22DID 3F44
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2018 to 2026.

Adaptation val.cylinder3 fast diagnosis VIRTUS_ADPT_VAL_CYL3_FAST

  • Service 22DID 3F46
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2018 to 2026.

Adaptation val.cylinder3 slow diagnosis VIRTUS_ADPT_VAL_CYL3_SLOW

  • Service 22DID 3F42
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2018 to 2026.

Adaptation val.cylinder4 fast diagnosis VIRTUS_ADPT_VAL_CYL4_FAST

  • Service 22DID 3F47
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2018 to 2026.

Adaptation val.cylinder4 slow diagnosis VIRTUS_ADPT_VAL_CYL4_SLOW

  • Service 22DID 3F43
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2018 to 2026.

Adaptive mode VIRTUS_ADAPTIVE_MODE

  • Service 22DID 1011
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Air conditioning compressor pressure VIRTUS_AC_COMP_P

  • Service 22DID 1017
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070
Unit
Raw value

In testing for 2018 to 2026.

Air conditioning compressor pressure, linear raw value VIRTUS_AC_COMP_P_LINEAR_RAW

  • Service 22DID 15C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070
Unit
Raw value

In testing for 2018 to 2026.

Air conditioning compressor refrigerant pressure VIRTUS_AC_COMP_REFRIGERANT_P

  • Service 22DID 1048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2018 to 2026.

Air conditioning compressor torque VIRTUS_AC_COMP_TQ

  • Service 22DID 101A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Air conditioning compressor torque VIRTUS_AC_COMP_TQ_7E0

  • Service 22DID 2017
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 N·m
Unit
N·m

In testing for 2018 to 2026.

Air conditioning compressor torque VIRTUS_AC_COMP_TQ_REQ

  • Service 22DID 1023
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2018 to 2026.

Air conditioning refrigerant pressure VIRTUS_AC_REFRIGERANT_P

  • Service 22DID 412A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2018 to 2026.

Air filling VIRTUS_AIR_FILLING

  • Service 22DID 121C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×11719500000
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Air leakage VIRTUS_AIR_LEAKAGE

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Air mass meter 1 VIRTUS_MQB_AIR_MASS_1

  • Service 22DID 1024
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2018 to 2026.

Air mass, actual value, mg/stroke VIRTUS_AIR_MASS_ACT_MG

  • Service 22DID 29D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2026.

Alternator load VIRTUS_ALTERNATOR_LOAD

  • Service 22DID 101C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Ambient air pressure VIRTUS_AMBIENT_AIR_P

  • Service 22DID 1509
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14
Unit
Raw value

In testing for 2018 to 2026.

Ambient air temperature, v1 VIRTUS_AAT_V1

  • Service 22DID 14F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.18−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2018 to 2026.

Ambient temperature VIRTUS_AAT_7E0

  • Service 22DID 1000
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2018 to 2026.

Ambient temperature VIRTUS_AAT_7E0_2

  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2018 to 2026.

Analysis, clutch 1, maximum temperature VIRTUS_ANALYSIS_CLU_1_MAX_T

  • Service 22DID 1064
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2026.

Analysis, clutch 2, maximum temperature VIRTUS_ANALYSIS_CLU_2_MAX_T

  • Service 22DID 1079
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2026.

Automatic transmission fluid temperature, lifetime max VIRTUS_ATF_MAX

  • Service 22DID 704F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2026.

Aux. hydraulic pump internal temperature VIRTUS_AUX_HYDRAULIC_PMP_T

  • Service 22DID 51A6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2026.

Aux. hydraulic pump, current VIRTUS_AUX_HYDRAULIC_PMP

  • Service 22DID 4E76
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 A
Unit
A

In testing for 2018 to 2026.

Average ignition timing angle delay adjustment VIRTUS_AVG_IGN_TIM_ANG

  • Service 22DID 2949
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Avg. injection time VIRTUS_AVG_INJ_TIME

  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×410000
Range
0 to 1717986 ms
Unit
ms

In testing for 2018 to 2026.

Avg. injection time, variant 2 VIRTUS_AVG_INJ_TIME_VAR_2

  • Service 22DID 2003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25 ms
Unit
ms

In testing for 2018 to 2026.

Basic correction factor:, cylinder 1, filtered VIRTUS_BASIC_CORR_FACTOR_1

  • Service 22DID 171A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×7.99965535
Range
0 to 7.999
Unit
Number

In testing for 2018 to 2026.

Basic correction factor:, cylinder 2, filtered VIRTUS_BASIC_CORR_FACTOR_2

  • Service 22DID 171D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×7.99965535
Range
0 to 7.999
Unit
Number

In testing for 2018 to 2026.

Basic correction factor:, cylinder 3, filtered VIRTUS_BASIC_CORR_FACTOR_3

  • Service 22DID 171B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×7.99965535
Range
0 to 7.999
Unit
Number

In testing for 2018 to 2026.

Basic correction factor:, cylinder 4, filtered VIRTUS_BASIC_CORR_FACTOR_4

  • Service 22DID 171C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×7.99965535
Range
0 to 7.999
Unit
Number

In testing for 2018 to 2026.

Boost press before throttle: calculated actual value VIRTUS_PQ35_BOOST_P_BEFORE_THROTTLE_CALCULATED_ACT

  • Service 22DID 181A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2500
Range
-81920000 to 81917500
Unit
Raw value

In testing for 2018 to 2026.

Boost pressure actuator, commanded duty VIRTUS_BOOST_P_ACTUATOR_CMD

  • Service 22DID 16EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.0122068184
Range
-399 to 100 %
Unit
%

In testing for 2018 to 2026.

Boost pressure, actual VIRTUS_BOOST_P_ACT_7E0

  • Service 22DID 111E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×225
Range
0 to 5242
Unit
Raw value

In testing for 2018 to 2026.

Boost pressure, target VIRTUS_BOOST_P_TGT

  • Service 22DID 1118
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550
Unit
Raw value

In testing for 2018 to 2026.

Boost regulation duty, commanded value VIRTUS_BOOST_REGULATION_CMD

  • Service 22DID 1219
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234384354
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Boost regulator feedback VIRTUS_BOOST_REGULATOR_FEEDBACK

  • Service 22DID 11CC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Bypass valve high pressure turbine inlet, activation VIRTUS_BYPASS_VLV_HIGH_P_TURBINE_INLET

  • Service 22DID 39FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Bypass valve high pressure turbine inlet, actual value VIRTUS_BYPASS_VLV_HIGH_P_ACT

  • Service 22DID 39FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1008192
Range
-400 to 100 %
Unit
%

In testing for 2018 to 2026.

Bypass valve high pressure turbine inlet, offset closed VIRTUS_BYPASS_VLV_HIGH_P

  • Service 22DID 39FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399 to 100 %
Unit
%

In testing for 2018 to 2026.

Bypass valve high pressure turbine inlet, offset open VIRTUS_BYPASS_VLV_HIGH_P_TURBINE

  • Service 22DID 39FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399 to 100 %
Unit
%

In testing for 2018 to 2026.

Bypass valve high pressure turbine inlet, target value VIRTUS_BYPASS_VLV_HIGH_P_TGT

  • Service 22DID 39FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1008192
Range
-400 to 100 %
Unit
%

In testing for 2018 to 2026.

Bze_q_elad VIRTUS_BZE_Q_ELAD

  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2018 to 2026.

Bze_q_lad VIRTUS_BZE_Q_LAD

  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2018 to 2026.

Cabin temperature VIRTUS_CABIN_TConfirmed

  • Service 22DID 2613
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x0150 = 336 → 33610 = 33.6 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Calculated oil temperature VIRTUS_PQ35_CALCULATED_OIL_T

  • Service 22DID 20A1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2026.

Camshaft adaptation exhaust bank 1, phase position VIRTUS_CAM_ADPT_EXH_BANK_1_PHASE

  • Service 22DID 2023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Camshaft adaptation intake bank 1, activation VIRTUS_CAM_ADPT_INT_BANK_1_ACTIVATION

  • Service 22DID 2930
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Camshaft adaptation intake bank 1, actual value VIRTUS_CAM_ADPT_INT_BANK_1_ACT

  • Service 22DID 201E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Camshaft adaptation intake bank 1, phase position VIRTUS_CAM_ADPT_INT_BANK_1_PHASE

  • Service 22DID 2021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Camshaft adaptation intake bank 1, specified value VIRTUS_CAM_ADPT_INT_BANK_1_SPEC

  • Service 22DID 201D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Camshaft adaptation intake, phase position VIRTUS_CAM_ADPT_INT_PHASE

  • Service 22DID 1093
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×359991638350
Range
-720 to 719 °
Unit
°

In testing for 2018 to 2026.

Camshaft adaptation, exhaust bank 1, phase position VIRTUS_CAM_ADPT_EXH_BANK_1

  • Service 22DID 1128
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×219.7310000
Range
-720 to 719 °
Unit
°

In testing for 2018 to 2026.

Camshaft adaptation, intake bank 1, phase position VIRTUS_CAM_ADPT_INT_BANK_1

  • Service 22DID 1125
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×219.7310000
Range
-720 to 719 °
Unit
°

In testing for 2018 to 2026.

Camshaft adaptation, intake deviation VIRTUS_CAM_ADPT_INT_DEV

  • Service 22DID 4FF5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment intake test bank 1 VIRTUS_CAM_ADJ_INT_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Camshaft adjustment outlet test bank 1 VIRTUS_CAM_ADJ_OUTLET_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Camshaft adjustment, exhaust bank 1, actual value VIRTUS_CAM_ADJ_EXH_BANK_1_ACT

  • Service 22DID 136C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, exhaust bank 1, specified value VIRTUS_CAM_ADJ_EXH_BANK_1_SPEC

  • Service 22DID 1371
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, exhaust bank 2, actual value VIRTUS_CAM_ADJ_EXH_BANK_2_ACT

  • Service 22DID 136D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, exhaust bank 2, specified value VIRTUS_CAM_ADJ_EXH_BANK_2_SPEC

  • Service 22DID 1372
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262 to 262 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, exhaust, activation VIRTUS_CAM_ADJ_EXH

  • Service 22DID 127B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Camshaft adjustment, exhaust, specified value VIRTUS_CAM_ADJ_EXH_SPEC

  • Service 22DID 2019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, intake bank 1, actual value VIRTUS_CAM_ADJ_INT_BANK_1_ACT

  • Service 22DID 136E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78.12510000
Range
-256 to 255 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, intake bank 1, specified value VIRTUS_CAM_ADJ_INT_BANK_1_SPEC

  • Service 22DID 1373
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2018 to 2026.

Camshaft end position VIRTUS_PQ35_CAMS_END

  • Service 22DID 1341
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 °
Unit
°

In testing for 2018 to 2026.

Camshaft position, deviation from the base position VIRTUS_CAM_POS_DEV_BASE_POS

  • Service 22DID 1385
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720 to 719 °
Unit
°

In testing for 2018 to 2026.

Camshaft start position VIRTUS_PQ35_CAMS_START

  • Service 22DID 1007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 °
Unit
°

In testing for 2018 to 2026.

Cat. converter oxygen storage capacity measured VIRTUS_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED_7E0

  • Service 22DID 1507
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Cat. temperature, bank 1 VIRTUS_CAT_T_BANK_1

  • Service 22DID 1298
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 2018 to 2026.

Cat. temperature, bank 2 VIRTUS_CAT_T_BANK_2

  • Service 22DID 1299
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 2018 to 2026.

Catalyst temperature, calculated VIRTUS_CAT_T_CALC

  • Service 22DID 1515
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5−50
Range
-50 to 1225 °C
Unit
°C

In testing for 2018 to 2026.

Centrifugal oil temperature VIRTUS_PQ35_CENTRIFUGAL_OIL_T

  • Service 22DID 38B2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2018 to 2026.

Chain elongation inlet, mileage at last adaptation VIRTUS_CHAIN_ELONGATION_INLET

  • Service 22DID 516C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2018 to 2026.

Chain elongation outlet, mileage at last adaptation VIRTUS_CHAIN_ELONGATION

  • Service 22DID 5149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2018 to 2026.

Chain elongation, no of valid initial values, exhaust bank 1 VIRTUS_CHAIN_ELONGATION_NO_VALID_1

  • Service 22DID 4189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Chain elongation, no of valid initial values, intake bank 1 VIRTUS_CHAIN_ELONGATION_NO_1

  • Service 22DID 4187
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Clutch #1 maximum temperature VIRTUS_PQ35_CLUTCH_1_MAXIMUM_T

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2018 to 2026.

Clutch #2 maximum temperature VIRTUS_PQ35_CLUTCH_2_MAXIMUM_T

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2018 to 2026.

Clutch 0 temperature calculated VIRTUS_MQB_DL382_CLUTCH_0_T_CALCULATED

  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2026.

Clutch 1 temperature VIRTUS_PQ35_CLUTCH_1_T

  • Service 22DID 102B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2018 to 2026.

Clutch 1 temperature protection overheat protection 1 quantity VIRTUS_MQB_TCM_CLUTCH_1_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY

  • Service 22DID 3881
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Clutch 1 temperature protection warning 1 quantity VIRTUS_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_1_QTY

  • Service 22DID 387F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Clutch 1 temperature protection warning 2 quantity VIRTUS_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_2_QTY

  • Service 22DID 3880
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Clutch 2 temperature VIRTUS_PQ35_CLUTCH_2_T

  • Service 22DID 102C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2018 to 2026.

Clutch 2 temperature protection overheat protection 1 quantity VIRTUS_MQB_TCM_CLUTCH_2_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY

  • Service 22DID 3885
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Clutch 2 temperature protection warning 1 quantity VIRTUS_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_1_QTY

  • Service 22DID 3883
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Clutch 2 temperature protection warning 2 quantity VIRTUS_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_2_QTY

  • Service 22DID 3884
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Clutch center central plate temperature VIRTUS_CLU_CENTER_CENTRAL_T

  • Service 22DID 102A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2026.

Clutch temperature calculated VIRTUS_MQB_DL382_CLUTCH_T_CALCULATED

  • Service 22DID 18E3
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2026.

Commanded crankshaft torque VIRTUS_CMD_CRANK_TQ

  • Service 22DID 11E0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Compression test cylinder 1 VIRTUS_PQ35_COMPRESSION_TEST_CYL_1

  • Service 22DID 1129
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2018 to 2026.

Compression test cylinder 2 VIRTUS_PQ35_COMP_TEST_CYL_2

  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2018 to 2026.

Compression test cylinder 3 VIRTUS_PQ35_COMP_TEST_CYL_3

  • Service 22DID 112B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2018 to 2026.

Compression test, cylinder 1 VIRTUS_COMPRESSION_TEST_CYL_1

  • Service 22DID 299B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2018 to 2026.

Compression test, cylinder 2 VIRTUS_COMPRESSION_TEST_CYL_2

  • Service 22DID 299C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2018 to 2026.

Compression test, cylinder 3 VIRTUS_COMPRESSION_TEST_CYL_3

  • Service 22DID 299D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2018 to 2026.

Compression test, cylinder 4 VIRTUS_COMPRESSION_TEST_CYL_4

  • Service 22DID 299E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2018 to 2026.

Control module temperature VIRTUS_CTRL_MODULE_T

  • Service 22DID 0301
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2026.

Converter loss torque VIRTUS_MQB_TCM_CONVERTER_LOSS_TORQUE

  • Service 22DID 1010
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Coolant at engine start VIRTUS_CLT_ENG_START

  • Service 22DID 1291
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Coolant circulation pump, activation VIRTUS_CLT_CIRCULATION_PMP_ACTIVATION

  • Service 22DID 276D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant circulation pump, control VIRTUS_CLT_CIRCULATION_PMP

  • Service 22DID 167E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant fan 1 activation, $1117 VIRTUS_CLT_FAN_1_ACTIVATION_1117

  • Service 22DID 1117
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2018 to 2026.

Coolant fan 1 duty cycle VIRTUS_PQ35_COOL_FAN_1_DUTY

  • Service 22DID 1116
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant fan 1, activation VIRTUS_CLT_FAN_1_ACTIVATION

  • Service 22DID 2055
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant fan 1, commanded duty VIRTUS_CLT_FAN_1_CMD_DUTY

  • Service 22DID 1130
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant fan 2 duty cycle VIRTUS_PQ35_COOL_FAN_2_DUTY

  • Service 22DID 1114
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant fan 2, activation VIRTUS_CLT_FAN_2_ACTIVATION

  • Service 22DID 2056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant fan, requested by A/C VIRTUS_CLT_FAN_REQ_AC

  • Service 22DID 1018
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant shut-off valve, closed VIRTUS_CLT_SHUT_OFF_VLV

  • Service 22DID 2682
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2018 to 2026.

Coolant temperature at engine outlet, calculated VIRTUS_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED_7E0

  • Service 22DID 4490
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at engine outlet, calculated VIRTUS_ECT_ENG_OUTLET_CALC

  • Service 22DID 1064
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at engine start VIRTUS_ECT_ENG_START

  • Service 22DID 2935
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at radiator outlet VIRTUS_COOLANT_T

  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at radiator outlet VIRTUS_ECT_RADIATOR_OUTLET

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at radiator outlet 2 VIRTUS_ECT_RAD_OUT_2

  • Service 22DID 109B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at radiator outlet v.1 VIRTUS_ECT_RADIATOR_OUTLET_V_1

  • Service 22DID 15CD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at radiator outlet v.3 VIRTUS_ECT_RADIATOR_OUTLET_V_3

  • Service 22DID 202B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at radiator outlet, actual value VIRTUS_ECT_RADIATOR_OUTLET_ACT_7E0

  • Service 22DID 102C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at radiator outlet, specified value VIRTUS_ECT_RADIATOR_OUTLET_SPEC

  • Service 22DID 202C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature difference between engine and radiator VIRTUS_ECT_DIFF_ENG

  • Service 22DID 202E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature linear VIRTUS_ECT_LINEAR

  • Service 22DID 1513
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29.29710000−48
Range
-48 to 143 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature modeled value VIRTUS_ECT_MODELED

  • Service 22DID 13A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature, maximum value VIRTUS_ECT_MAX

  • Service 22DID 1511
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature, minimum value VIRTUS_ECT_MIN

  • Service 22DID 1512
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Correction factor of oil temperature for engine protection VIRTUS_CORR_FACTOR_OIL_T

  • Service 22DID 3F4F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12207100000000
Range
0 to 7.99
Unit
Number

In testing for 2018 to 2026.

Correction values for main pressure adaptation VIRTUS_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT

  • Service 22DID 11A7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Counter steer support VIRTUS_CNT_STEER_SUPPORT_ACTIVEConfirmed

  • Service 22DID 18B6
  • Module713 → 77D
  • Every900 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Counter steer support, steering torque VIRTUS_CNT_STEER_SUPPORT_STEERING_TRQConfirmed

  • Service 22DID 18B6
  • Module713 → 77D
  • Every900 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 1 N·m
Unit
N·m

0x0000 = 0 → 01000 = 0 N·m

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Crankshaft rotation angle when closing the quantity control valve VIRTUS_CRANK_ROT_ANG

  • Service 22DID 10EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 0 VIRTUS_CTR_MIS_DC_MMV_CYL_0

  • Service 22DID 148D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 1 VIRTUS_CTR_MIS_DC_MMV_CYL_1

  • Service 22DID 148E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 2 VIRTUS_CTR_MIS_DC_MMV_CYL_2

  • Service 22DID 148F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Current N215 pressure control valve 1 VIRTUS_CURRENT_N215_P_CTRL_1

  • Service 22DID 1024
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2018 to 2026.

Current N216 pressure control valve 2 VIRTUS_CURRENT_N216_P_CTRL_2

  • Service 22DID 1026
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2018 to 2026.

Current N217 pressure control valve 3 VIRTUS_CURRENT_N217_P_CTRL_3

  • Service 22DID 1028
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2018 to 2026.

Current N218 pressure control valve 4 VIRTUS_CURRENT_N218_P_CTRL_4

  • Service 22DID 1025
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2018 to 2026.

Current N233 pressure control valve 5 VIRTUS_CURRENT_N233_P_CTRL_5

  • Service 22DID 1027
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2018 to 2026.

Current solenoid VIRTUS_CURRENT_SOLENOID

  • Service 22DID 1037
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2018 to 2026.

Current type of driver counter VIRTUS_CURRENT_TYPE_DRIVER

  • Service 22DID 1013
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Cylinder 1 internal torque VIRTUS_CYL_1_INTERNAL_TQ

  • Service 22DID 5847
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Cylinder 2 internal torque VIRTUS_CYL_2_INTERNAL_TQ

  • Service 22DID 5849
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Cylinder 3 internal torque VIRTUS_CYL_3_INTERNAL_TQ

  • Service 22DID 584B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Cylinder 4 internal torque VIRTUS_CYL_4_INTERNAL_TQ

  • Service 22DID 584D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Cylinder block temperature sensor VIRTUS_CYL_BLOCK_T_SENS

  • Service 22DID 51D4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Cylinder head temperature VIRTUS_CYL_HEAD_T

  • Service 22DID 1065
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.18−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2018 to 2026.

Desired torque raw VIRTUS_DES_TQ_RAW

  • Service 22DID 1061
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2018 to 2026.

Differential pressure VIRTUS_PQ35_DIFF_P

  • Service 22DID 14F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Direct injections counter VIRTUS_DIRECT_INJECTIONS

  • Service 22DID 4267
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2018 to 2026.

Drive motor current VIRTUS_MOTOR_I

  • Service 22DID 147D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 A
Unit
A

In testing for 2018 to 2026.

Drive motor torque VIRTUS_MOTOR_TQ

  • Service 22DID 147F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val3
Range
-10922.666 to 10922.333 N·m
Unit
N·m

In testing for 2018 to 2026.

Driver demand torque VIRTUS_MQB_TCM_DRIVER_DEMAND_TORQUE

  • Service 22DID 100B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Driving mode sensor, hall sensor a VIRTUS_DRIVING_MODE_SENS

  • Service 22DID 210D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Driving position VIRTUS_DRIVING_POS

  • Service 22DID 210E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Driving resistance index VIRTUS_DRIVING_RES_INDEX

  • Service 22DID 2108
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2018 to 2026.

Dynamic average of ignition angle delay adjustment VIRTUS_DYNAMIC_AVG_IGN_ANG

  • Service 22DID 294A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Ea888b boost pressure control, adaptation value 0 VIRTUS_EA888B_BOOST_P_CTRL_0

  • Service 22DID 11FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2018 to 2026.

Ea888b boost pressure control, adaptation value 1 VIRTUS_EA888B_BOOST_P_CTRL_1

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2018 to 2026.

Ea888b boost pressure control, adaptation value 2 VIRTUS_EA888B_BOOST_P_CTRL_2

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2018 to 2026.

Ea888b boost pressure control, adaptation value 3 VIRTUS_EA888B_BOOST_P_CTRL_3

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2018 to 2026.

Ea888b boost pressure regulator, commanded VIRTUS_EA888B_BOOST_P_CMD

  • Service 22DID 11A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Early ignition counter for toque reduction, cylinder 1 VIRTUS_EARLY_IGN_CNT_TOQUE_1

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter for toque reduction, cylinder 2 VIRTUS_EARLY_IGN_CNT_TOQUE_2

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter for toque reduction, cylinder 3 VIRTUS_EARLY_IGN_CNT_TOQUE_3

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter for toque reduction, cylinder 4 VIRTUS_EARLY_IGN_CNT_TOQUE_4

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder 1 VIRTUS_EARLY_IGN_CNT_CYL_1

  • Service 22DID 1722
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder 2 VIRTUS_EARLY_IGN_CNT_CYL_2

  • Service 22DID 1725
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder 3 VIRTUS_EARLY_IGN_CNT_CYL_3

  • Service 22DID 1723
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder 4 VIRTUS_EARLY_IGN_CNT_CYL_4

  • Service 22DID 1724
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 1 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_1

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 2 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_2

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 3 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_3

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 4 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_4

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 1 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_1

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 2 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_2

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 3 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_3

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 4 VIRTUS_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_4

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, total, cylinder 1 VIRTUS_EARLY_IGN_CNT_TOT_1

  • Service 22DID 1715
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, total, cylinder 2 VIRTUS_EARLY_IGN_CNT_TOT_2

  • Service 22DID 1718
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, total, cylinder 3 VIRTUS_EARLY_IGN_CNT_TOT_3

  • Service 22DID 1716
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, total, cylinder 4 VIRTUS_EARLY_IGN_CNT_TOT_4

  • Service 22DID 1717
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Effective injection duration VIRTUS_EFFECTIVE_INJ_DUR

  • Service 22DID 15E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

In testing for 2018 to 2026.

EGT after catalyst, model bank b VIRTUS_EGT_AFTER_CAT_MODEL_B

  • Service 22DID 2AE3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.023438−273.15
Range
-273 to 1262 °C
Unit
°C

In testing for 2018 to 2026.

EGT after catalyst, modeled VIRTUS_EGT_AFTER_CAT

  • Service 22DID 1272
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

EGT at lambda sensor 1, modeled VIRTUS_EGT_LAMBDA_SENS_1

  • Service 22DID 139C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Electric additional coolant pump control, high circle VIRTUS_ELEC_ADDITIONAL_CLT

  • Service 22DID 1488
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2018 to 2026.

Energy balance of last driving cycle VIRTUS_ENERGY_BALANCE_LAST

  • Service 22DID 2A15
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 Ah
Unit
Ah

In testing for 2018 to 2026.

Energy content VIRTUS_ENERGY_CONTENT

  • Service 22DID 22E4
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2018 to 2026.

Engine air mass, specified value VIRTUS_ENG_AIR_MASS_SPEC

  • Service 22DID 2037
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Engine compartment temperature raw value VIRTUS_ENG_COMPARTMENT_T

  • Service 22DID 46B1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 2018 to 2026.

Engine control module temperature VIRTUS_ENG_CTRL_MODULE_TConfirmed

  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

0x0C3C = 3132 → 313210−273.1 = 40.1 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.

Engine control unit temperature VIRTUS_MQB_TCM_ECU_T

  • Service 22DID 028D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2018 to 2026.

Engine drag torque VIRTUS_ENG_DRAG_TQ

  • Service 22DID 209C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine oil level VIRTUS_ENG_OIL_LEVEL_7E0

  • Service 22DID 1504
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mm
Unit
mm

In testing for 2018 to 2026.

Engine oil level VIRTUS_PQ35_OIL_LVL

  • Service 22DID 11BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 mm
Unit
mm

In testing for 2018 to 2026.

Engine oil level current value VIRTUS_ENG_OIL_LEVEL

  • Service 22DID 58D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Engine oil pressure VIRTUS_EOP

  • Service 22DID 1503
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val416
Range
0 to 157 psi
Unit
psi

In testing for 2018 to 2026.

Engine oil sump temperature VIRTUS_ENG_OIL_SUMP_T

  • Service 22DID 15B7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.18−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2018 to 2026.

Engine oil temperature VIRTUS_EOT_7E0_7E0

  • Service 22DID 1102
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2026.

Engine oil temperature measured value VIRTUS_EOT_MEAS

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2018 to 2026.

Engine oil temperature, calculated VIRTUS_EOT_CALC

  • Service 22DID 201A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2018 to 2026.

Engine oil temperature, engine control module VIRTUS_EOT_ECMConfirmed

  • Service 22DID 11BD
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-40 to 200 °C
Unit
°C

0x0BB0 = 2992 → 299210−273.1 = 26.1 °C

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Engine oil temperature, pulse sensor VIRTUS_EOT_PULS

  • Service 22DID 179E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2018 to 2026.

Engine oil temperature, variant 3 VIRTUS_EOT_VAR_3

  • Service 22DID 202F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Engine oil temperature, variant 4 VIRTUS_EOT_VAR_4

  • Service 22DID 40D5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Engine outlet coolant temperature calculated VIRTUS_ENG_OUTLET_ECT_CALC

  • Service 22DID 1063
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Engine protection, torque limit VIRTUS_ENG_PROTECTION_TQ

  • Service 22DID 2BC0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine radiator fan request VIRTUS_ENG_RADIATOR_FAN_REQ

  • Service 22DID 100B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Engine start quantity VIRTUS_PQ35_ENG_START_QTY

  • Service 22DID 1069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2026.

Engine temperature control actuator VIRTUS_ENG_T_CTRL_ACTUATOR

  • Service 22DID 3D73
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Engine temperature management actuator, after-run stop VIRTUS_ENG_T_MANAGEMENT_ACTUATOR_AFTER

  • Service 22DID 441D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Engine temperature management actuator, duty cycle activation VIRTUS_ENG_T_MANAGEMENT_ACTUATOR

  • Service 22DID 441A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Engine temperature management actuator, raw value VIRTUS_ENG_T_MANAGEMENT

  • Service 22DID 4419
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Engine temperature management actuator, specified value VIRTUS_ENG_T_MANAGEMENT_SPEC

  • Service 22DID 3FE4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2018 to 2026.

Engine temperature management actuator, stop open VIRTUS_ENG_T_MANAGEMENT_ACTUATOR_STOP

  • Service 22DID 441C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Engine torque VIRTUS_ENG_TQ

  • Service 22DID 1010
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque VIRTUS_ENG_TQ_7E0

  • Service 22DID 2002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque VIRTUS_ENG_TQ_7E0_7E0

  • Service 22DID 437C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque VIRTUS_ENG_TQ_7E1

  • Service 22DID 2002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque VIRTUS_MQB_TCM_ENG_TORQUE

  • Service 22DID 7064
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque VIRTUS_MQB_TCM_ENGINE_TORQUE

  • Service 22DID 100C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque VIRTUS_PQ35_ENG_TORQUE

  • Service 22DID 155A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque VIRTUS_PQ35_ENG_TRQ

  • Service 22DID 1047
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque limitation VIRTUS_ENG_TQ_LIM

  • Service 22DID 108F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque limitation VIRTUS_MQB_TCM_ENGINE_TORQUE_LIMITATION

  • Service 22DID 100E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque loss VIRTUS_MQB_TCM_ENGINE_TORQUE_LOSS

  • Service 22DID 100F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Environment data camshaft input 1 VIRTUS_PQ35_ENVD_CAM_IN_1

  • Service 22DID 1213
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Excessive temperature protection VIRTUS_EXCESSIVE_T

  • Service 22DID 2117
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Exhaust camshaft, adaptation bias VIRTUS_EXH_CAM_ADPT_BIAS

  • Service 22DID 174A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720 to 719 °
Unit
°

In testing for 2018 to 2026.

Exhaust camshaft, adaptation sensor tolerance VIRTUS_EXH_CAM_ADPT_SENS

  • Service 22DID 1755
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720 to 719 °
Unit
°

In testing for 2018 to 2026.

Exhaust gas jet volume in particle filter VIRTUS_EXH_GAS_JET_VOLUME

  • Service 22DID 3D7E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700 L
Unit
L

In testing for 2018 to 2026.

Exhaust gas recirculation valve 2 bank 1 mass flow VIRTUS_MQB_EGR_VALVE_2_B1_FLOW

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2018 to 2026.

Exhaust gas recirculation valve duty VIRTUS_PQ35_EGR_DUTY

  • Service 22DID 10C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Exhaust gas temperature VIRTUS_EXH_GAS_T

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature - calculated after catalyst VIRTUS_EXH_GAS_T_CALC_AFTER

  • Service 22DID 2AE9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29312500−273.15
Range
-273.15 to 1262.9904 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature before catalyst VIRTUS_EXHAUST_GAS_T_BEFORE_CATALYST

  • Service 22DID 1282
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50−193.93
Range
-193.93 to 1116.77 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature before catalytic converter VIRTUS_EXH_GAS_T_BEFORE

  • Service 22DID 296F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature sensor 1 VIRTUS_EXH_GAS_T_SENS_1

  • Service 22DID 2976
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature sensor 1 VIRTUS_PQ35_EXH_GAS_T_1

  • Service 22DID 10FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature sensor 2 VIRTUS_PQ35_EXHAUST_GAS_T_SENSOR_2

  • Service 22DID 14F7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature sensor 4 VIRTUS_EXH_GAS_T_SENS_4

  • Service 22DID 166D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature, sensor 4, bank 2 VIRTUS_EXH_GAS_T_S4_B2

  • Service 22DID 166E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust temperature before the catalyst, modeled VIRTUS_EXH_T_BEFORE_CAT

  • Service 22DID 1421
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust temperature control downstream oxidation catalyst filtered model error VIRTUS_MQB_EXH_TEMP_CTRL_AFTER_CAT_MODEL_ERR

  • Service 22DID 1AD7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Field limit value VIRTUS_PQ35_FIELD_LIM

  • Service 22DID 11F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2018 to 2026.

Field regeneration request status VIRTUS_FIELD_REGEN_REQ_STAT

  • Service 22DID 2087
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Front left deflector temperature VIRTUS_CLIMATE_FR_L_DEFL_TConfirmed

  • Service 22DID 260C
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

0x70 = 112 → 112×0.333 = 37.296 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Front right deflector temperature VIRTUS_CLIMATE_FR_R_DEFL_TConfirmed

  • Service 22DID 260D
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

0x70 = 112 → 112×0.333 = 37.296 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Fuel temperature VIRTUS_PQ35_FUEL_T

  • Service 22DID 162D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Generator current VIRTUS_GEN_CURRENT

  • Service 22DID 2A1C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10+9
Range
0 to 6562.5 A
Unit
A

In testing for 2018 to 2026.

Generator load normalized value VIRTUS_GENERATOR_LOAD_NORMALIZED_VALUE_7E0

  • Service 22DID 15CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Generator load signal VIRTUS_GEN_LOAD_SIG

  • Service 22DID 2050
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Generator load signal VIRTUS_GEN_LOAD_SIG_7E0

  • Service 22DID 1033
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2018 to 2026.

Generator power VIRTUS_GEN_POWER

  • Service 22DID 1097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9.4247
Range
0 to 617647.7145 W
Unit
W

In testing for 2018 to 2026.

Generator torque request VIRTUS_GENERATOR_TORQUE_REQUEST_7E0

  • Service 22DID 101B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Heater circulation pump, nominal value VIRTUS_HEATER_CIRCULATION

  • Service 22DID 167F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Heater support pump, specified value VIRTUS_HEATER_SUPPORT_PMP_SPEC

  • Service 22DID 4336
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Height correction VIRTUS_HEIGHT_CORR

  • Service 22DID 1136
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000610348
Range
0 to 3.9999
Unit
Number

In testing for 2018 to 2026.

High pressure control, adaptation VIRTUS_HIGH_P_CTRL_ADPT

  • Service 22DID 11D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2018 to 2026.

High pressure EGR actuator, activation VIRTUS_HIGH_P_EGR_ACTUATOR

  • Service 22DID 1334
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2018 to 2026.

High pressure regulation, adaptation value VIRTUS_HIGH_P_REGULATION

  • Service 22DID 4384
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2018 to 2026.

Hybrid temperature VIRTUS_MQB_TCM_HYBRID_T

  • Service 22DID 1196
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2018 to 2026.

ID of current driving program VIRTUS_ID_CURRENT_DRIVING

  • Service 22DID 1012
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

IGA_CYL_KNK, 0 VIRTUS_IGA_CYL_KNK_0

  • Service 22DID 13F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2018 to 2026.

IGA_CYL_KNK, 1 VIRTUS_IGA_CYL_KNK_1

  • Service 22DID 13F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2018 to 2026.

IGA_CYL_KNK, 2 VIRTUS_IGA_CYL_KNK_2

  • Service 22DID 13F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2018 to 2026.

IGA_CYL_KNK, 3 VIRTUS_IGA_CYL_KNK_3

  • Service 22DID 13F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2018 to 2026.

IGA_IGC, 0 VIRTUS_IGA_IGC_0

  • Service 22DID 138A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2018 to 2026.

IGA_IGC, 1 VIRTUS_IGA_IGC_1

  • Service 22DID 138B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2018 to 2026.

IGA_IGC, 2 VIRTUS_IGA_IGC_2

  • Service 22DID 138C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2018 to 2026.

IGA_IGC, 3 VIRTUS_IGA_IGC_3

  • Service 22DID 138D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2018 to 2026.

Ignition angle current cylinder, actual value VIRTUS_IGN_ANG_CURRENT_CYL_ACT

  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-25 to 25 °
Unit
°

In testing for 2018 to 2026.

Injection amount deviation cylinder 1 VIRTUS_INJ_AMOUNT_DEV_CYL_1

  • Service 22DID 2046
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2018 to 2026.

Injection amount deviation cylinder 1 VIRTUS_PQ35_INJ_DEV_CYL_1

  • Service 22DID 10FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2026.

Injection amount deviation cylinder 2 VIRTUS_INJ_AMOUNT_DEV_CYL_2

  • Service 22DID 2047
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2018 to 2026.

Injection amount deviation cylinder 2 VIRTUS_PQ35_INJ_DEV_CYL_2

  • Service 22DID 1105
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2026.

Injection amount deviation cylinder 3 VIRTUS_INJ_AMOUNT_DEV_CYL_3

  • Service 22DID 2048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2018 to 2026.

Injection amount deviation cylinder 3 VIRTUS_PQ35_INJ_DEV_CYL_3

  • Service 22DID 1100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2026.

Injection amount deviation cylinder 4 VIRTUS_INJ_AMOUNT_DEV_CYL_4

  • Service 22DID 2049
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2018 to 2026.

Injection amount deviation cylinder 4 VIRTUS_PQ35_INJ_DEV_CYL_4

  • Service 22DID 1104
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2026.

Injection quantity deviation, cylinder 2 VIRTUS_INJ_QTY_DEV_CYL_2

  • Service 22DID 204A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2018 to 2026.

Injection quantity deviation, cylinder 5 VIRTUS_INJ_QTY_DEV_CYL_5

  • Service 22DID 204B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2018 to 2026.

Injector 1 rail pressure calibration point 1 VIRTUS_PQ35_INJ_1_RAIL_P_1

  • Service 22DID 10D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2018 to 2026.

Injector 1 rail pressure calibration point 2 VIRTUS_PQ35_INJ_1_RAIL_P_2

  • Service 22DID 10D6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2018 to 2026.

Injector 1 rail pressure calibration point 3 VIRTUS_PQ35_INJ_1_RAIL_P_3

  • Service 22DID 10DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2018 to 2026.

Injector 2 rail pressure calibration point 1 VIRTUS_PQ35_INJ_2_RAIL_P_1

  • Service 22DID 10D3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2018 to 2026.

Injector 2 rail pressure calibration point 2 VIRTUS_PQ35_INJ_2_RAIL_P_2

  • Service 22DID 10D9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2018 to 2026.

Injector 2 rail pressure calibration point 3 VIRTUS_PQ35_INJ_2_RAIL_P_3

  • Service 22DID 10DF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2018 to 2026.

Injector 2: rail pressure calibration point 1 VIRTUS_INJ_2_RAIL_P_CAL_PT_1_146E

  • Service 22DID 146E
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Injector 2: rail pressure calibration point 2 VIRTUS_INJ_2_RAIL_P_CAL_PT_2_1474

  • Service 22DID 1474
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Injector 2: rail pressure calibration point 3 VIRTUS_INJ_2_RAIL_P_CAL_PT_3_147A

  • Service 22DID 147A
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Injector 3 rail pressure calibration point 1 VIRTUS_PQ35_INJ_3_RAIL_P_1

  • Service 22DID 10D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2018 to 2026.

Injector 3 rail pressure calibration point 2 VIRTUS_PQ35_INJ_3_RAIL_P_2

  • Service 22DID 10D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2018 to 2026.

Injector 3 rail pressure calibration point 3 VIRTUS_PQ35_INJ_3_RAIL_P_3

  • Service 22DID 10DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2018 to 2026.

Injector 4 rail pressure calibration point 2 VIRTUS_PQ35_INJ_4_RAIL_P_2

  • Service 22DID 10D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2018 to 2026.

Injector 4 rail pressure calibration point 3 VIRTUS_PQ35_INJ_4_RAIL_P_3

  • Service 22DID 10DE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2018 to 2026.

Injector 7: rail pressure calibration point 1 VIRTUS_INJ_7_RAIL_P_CAL_PT_1

  • Service 22DID 146D
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Injector 7: rail pressure calibration point 2 VIRTUS_INJ_7_RAIL_P_CAL_PT_2

  • Service 22DID 1473
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Injector 7: rail pressure calibration point 3 VIRTUS_INJ_7_RAIL_P_CAL_PT_3

  • Service 22DID 1479
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Inlet flaps - actual value VIRTUS_INLET_FLAPS_ACT

  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Inlet flaps - requested value VIRTUS_INLET_FLAPS_REQ

  • Service 22DID 11A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Intake air temperature VIRTUS_IAT_7E0

  • Service 22DID 1001
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2018 to 2026.

Intake air temperature before throttle valve, raw value VIRTUS_IAT_BEFORE_THROTTLE

  • Service 22DID 15C1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×75100−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Intake air temperature in intake manifold VIRTUS_INTAKE_AIR_T_IN_INTAKE_MANIFOLD_7E0

  • Service 22DID 149E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Intake air temperature in intake manifold raw value VIRTUS_IAT_INT_MANIFOLD_RAW

  • Service 22DID 15C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Intake camshaft adaptation unit 1 phase length VIRTUS_PQ35_CAMS_ADAPT_PHASE_1

  • Service 22DID 12FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2018 to 2026.

Intake camshaft signal edge position adapted edge 2 VIRTUS_PQ35_CAMS_EDGE_POS_2

  • Service 22DID 1189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2018 to 2026.

Intake camshaft signal edge position adapted edge 3 VIRTUS_PQ35_CAMS_EDGE_POS_3

  • Service 22DID 118A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2018 to 2026.

Intake camshaft signal edge position adapted edge 4 VIRTUS_PQ35_CAMS_EDGE_POS_4

  • Service 22DID 118B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2018 to 2026.

Intake camshaft signal edge position adapted edge 5 VIRTUS_PQ35_CAMS_EDGE_POS_5

  • Service 22DID 118C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2018 to 2026.

Intake camshaft signal edge position adapted edge 6 VIRTUS_PQ35_CAMS_EDGE_POS_6

  • Service 22DID 118D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2018 to 2026.

Intake camshaft signal edge position adapted edge 7 VIRTUS_PQ35_CAMS_EDGE_POS_7

  • Service 22DID 118E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2018 to 2026.

Intake camshaft signal edge position adapted edge 8 VIRTUS_PQ35_CAMS_EDGE_POS_8

  • Service 22DID 118F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2018 to 2026.

Intake camshaft signal edge position adapted value edge 1 VIRTUS_PQ35_INTAKE_CAMSHAFT_SIGNAL_EDGE_POS_ADAPTED_VALUE_EDGE_1

  • Service 22DID 173A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2018 to 2026.

Intake camshaft, adaptation bias VIRTUS_INT_CAM_ADPT_BIAS

  • Service 22DID 174B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720 to 719 °
Unit
°

In testing for 2018 to 2026.

Intake camshaft, adaptation sensor tolerance VIRTUS_INT_CAM_ADPT_SENS

  • Service 22DID 1740
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720 to 719 °
Unit
°

In testing for 2018 to 2026.

Intake manifold pressure calculated VIRTUS_MQB_INT_MAN_P

  • Service 22DID 103C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Intake manifold pressure raw value VIRTUS_INT_MANIFOLD_P_RAW

  • Service 22DID 11DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×781.2510000
Range
0 to 19.92
Unit
Raw value

In testing for 2018 to 2026.

Intake manifold pressure raw value VIRTUS_INT_MANIFOLD_P_RAW_7E0

  • Service 22DID 3E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2018 to 2026.

Intake manifold pressure, commanded VIRTUS_INT_MANIFOLD_P_CMD

  • Service 22DID 11DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.078125
Range
0 to 5119
Unit
Raw value

In testing for 2018 to 2026.

Intake manifold pressure, corrected VIRTUS_INT_MANIFOLD_P

  • Service 22DID 11DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.078125
Range
0 to 5119
Unit
Raw value

In testing for 2018 to 2026.

Intake manifold runner control, acknowledgment VIRTUS_INT_MANIFOLD_RUNNER_CTRL

  • Service 22DID 206A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Intake manifold runner control, activation VIRTUS_INT_MANIFOLD_RUNNER

  • Service 22DID 2069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Intake model air mass flow filtered value VIRTUS_INT_MODEL_AIR_MASS

  • Service 22DID 11AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Intake phase deviation, actual value VIRTUS_INT_PHASE_DEV_ACT

  • Service 22DID 1800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2018 to 2026.

Integrated mass of air since engine start VIRTUS_INTEGRATED_MASS_AIR

  • Service 22DID 1175
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2018 to 2026.

Integrated mass of air since the first engine start VIRTUS_INTEGRATED_MASS_AIR_SINCE

  • Service 22DID 1743
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2018 to 2026.

Intercooler air output temperature VIRTUS_PQ35_INTERCOOLER_AIR_OUTPUT_T

  • Service 22DID 1628
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Kick down VIRTUS_MQB_TCM_KICK_DOWN

  • Service 22DID 2114
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Kilometers driven since last event on K1 VIRTUS_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1

  • Service 22DID 115A
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

In testing for 2018 to 2026.

Kilometers driven since last event on K2 VIRTUS_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2

  • Service 22DID 115C
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

In testing for 2018 to 2026.

Knock retard 2 VIRTUS_KNOCK_RETARD_2

  • Service 22DID 10E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

In testing for 2018 to 2026.

Knock retard 2,, variant 1 VIRTUS_KNOCK_RETARD_2_VAR_1

  • Service 22DID 10E5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2018 to 2026.

Knock sensor 1 test VIRTUS_KNOCK_SENS_1_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Knock sensor 2 test VIRTUS_KNOCK_SENS_2_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Knock sensor 3 test VIRTUS_KNOCK_SENS_3_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Knock sensor 4 test VIRTUS_KNOCK_SENS_4_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Knock sensor based camshaft angle adjustment counter VIRTUS_KNOCK_CAM_ANG_ADJ

  • Service 22DID 523B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Knock sensor, cylinder 1 VIRTUS_KNOCK_SENS_CYL_1

  • Service 22DID 120E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048489933
Range
0 to 317 V
Unit
V

In testing for 2018 to 2026.

Knock sensor, cylinder 1, variant 2 VIRTUS_KNOCK_SENS_CYL_1_VAR_2

  • Service 22DID 3960
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Knock sensor, cylinder 2 VIRTUS_KNOCK_SENS_CYL_2

  • Service 22DID 1211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048489933
Range
0 to 317 V
Unit
V

In testing for 2018 to 2026.

Knock sensor, cylinder 2 VIRTUS_KNOCK_SENS_CYL_2_7E0

  • Service 22DID 1212
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×7.62e-7
Range
0 to 3272
Unit
Number

In testing for 2018 to 2026.

Knock sensor, cylinder 2, variant 2 VIRTUS_KNOCK_SENS_CYL_2_VAR_2

  • Service 22DID 3961
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Knock sensor, cylinder 3 VIRTUS_KNOCK_SENS_CYL_3

  • Service 22DID 120F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048489933
Range
0 to 317 V
Unit
V

In testing for 2018 to 2026.

Knock sensor, cylinder 3, variant 2 VIRTUS_KNOCK_SENS_CYL_3_VAR_2

  • Service 22DID 3962
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Knock sensor, cylinder 4 VIRTUS_KNOCK_SENS_CYL_4

  • Service 22DID 1210
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048489933
Range
0 to 317 V
Unit
V

In testing for 2018 to 2026.

Knock sensor, cylinder 4, variant 2 VIRTUS_KNOCK_SENS_CYL_4_VAR_2

  • Service 22DID 3963
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Lambda output value VIRTUS_LAMBDA_OUTPUT

  • Service 22DID 15D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.99
Unit
Number

In testing for 2018 to 2026.

Lambda, actual value VIRTUS_LAMBDA_ACT

  • Service 22DID 10D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1220750000000
Range
-7.9999 to 7.9997
Unit
Number

In testing for 2018 to 2026.

Launch control counter, variant 1 VIRTUS_LAUNCH_CTRL_CNT_VAR_1

  • Service 22DID 1200
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Launch control counter, variant 2 VIRTUS_LAUNCH_CTRL_CNT_VAR_2

  • Service 22DID 38F1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Leg deflector temperature VIRTUS_CLIMATE_LEG_DEFL_TConfirmed

  • Service 22DID 2611
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

0x78 = 120 → 120×0.333 = 39.96 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Long term fuel trim at idle, direct injection VIRTUS_LONG_TERM_FUEL_TRIM_IDLE

  • Service 22DID 177E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2018 to 2026.

Long term fuel trim at idle, port injection VIRTUS_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ

  • Service 22DID 1780
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2018 to 2026.

Long term throttle adaptation to MAF sensor VIRTUS_LONG_TERM_THROTTLE

  • Service 22DID 113A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000610351
Range
0 to 3.99 %
Unit
%

In testing for 2018 to 2026.

Long-term adaptation of intake manifold injection VIRTUS_LONG_TERM_ADPT_INT

  • Service 22DID 414E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2018 to 2026.

Long-term adaptation of intake manifold injection at idle VIRTUS_LONG_TERM_ADPT_INT_MANIFOLD_INJ

  • Service 22DID 414F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2018 to 2026.

Lost torque adaptation A/C + driving mode VIRTUS_LOST_TQ_ADPT_AC

  • Service 22DID 437F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2018 to 2026.

Lost torque adaptation driving mode VIRTUS_LOST_TQ_ADPT_DRIVING

  • Service 22DID 437E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2018 to 2026.

Low press. EGR closing VIRTUS_LOW_PRESS_EGR

  • Service 22DID 406B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Low pressure EGR closing VIRTUS_LOW_P_EGR_CLOSING

  • Service 22DID 17F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×-252048+100
Range
-699 to 100 %
Unit
%

In testing for 2018 to 2026.

Lower adapted coupling point K2 from micro-slip path adaptation VIRTUS_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPT

  • Service 22DID 110A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2018 to 2026.

M009, desired solenoid out 10 VIRTUS_M009_DES_SOLENOID_10

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

M009, desired solenoid out 11 VIRTUS_M009_DES_SOLENOID_11

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

M009, desired solenoid out 12 VIRTUS_M009_DES_SOLENOID_12

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

M009, desired solenoid out 13 VIRTUS_M009_DES_SOLENOID_13

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

M009, desired solenoid out 14 VIRTUS_M009_DES_SOLENOID_14

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Main catalyst aging factor VIRTUS_MAIN_CAT_AGING

  • Service 22DID 14F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.30517586100000
Range
0 to 0.199
Unit
Number

In testing for 2018 to 2026.

Main injection duration VIRTUS_PQ35_MAIN_INJ_DURATION

  • Service 22DID 14CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2018 to 2026.

Main injection start position VIRTUS_PQ35_MAIN_INJ_START

  • Service 22DID 11F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2018 to 2026.

Mass air flow over throttle valve VIRTUS_MAF_OVER_THROTTLE

  • Service 22DID 394F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Mass air flow rate VIRTUS_MAF_RATE

  • Service 22DID 13CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047
Unit
Raw value

In testing for 2018 to 2026.

Mass air flow through throttle VIRTUS_MAF_THROUGH_THROTTLE

  • Service 22DID 11AC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Mass air flow, commanded VIRTUS_MAF_CMD

  • Service 22DID 11AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Mass airflow sensor 1 bank 1 raw value VIRTUS_MQB_MAF_1_B1_RAW

  • Service 22DID 1026
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2018 to 2026.

Mass flow through throttle valve VIRTUS_MASS_FLOW_THROUGH

  • Service 22DID 110A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2018 to 2026.

Max permissible engine torque VIRTUS_MAX_PERMISSIBLE_ENG

  • Service 22DID 211A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2018 to 2026.

Maximum ECU temperature VIRTUS_MAX_ECU_T

  • Service 22DID 4649
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Maximum filling correction factor from knock control VIRTUS_MAX_FILLING_CORR

  • Service 22DID 10E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3100000
Range
0 to 1.96
Unit
Number

In testing for 2018 to 2026.

Maximum oil level for the service interval VIRTUS_MAX_OIL_LEVEL

  • Service 22DID 1230
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2018 to 2026.

Mean engine air mass VIRTUS_MEAN_ENG_AIR_MASS

  • Service 22DID 2032
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Mean engine air mass VIRTUS_PQ35_MEAN_AIR_MASS

  • Service 22DID 1314
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047
Unit
Raw value

In testing for 2018 to 2026.

Mean injection quantity VIRTUS_MEAN_INJ_QTY

  • Service 22DID 2097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Mean injection quantity VIRTUS_MEAN_INJ_QUANTITY

  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Mileage with ECU installed VIRTUS_MILEAGE_ECU

  • Service 22DID 10A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2018 to 2026.

Minimum oil level for the service interval VIRTUS_MIN_OIL_LEVEL

  • Service 22DID 1231
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2018 to 2026.

Misfires / 1000 revolutions, cylinder 1 VIRTUS_MISFIRES_1000REV_C1

  • Service 22DID 1147
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires / 1000 revolutions, cylinder 2 VIRTUS_MISFIRES_1000REV_C2

  • Service 22DID 114A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires / 1000 revolutions, cylinder 3 VIRTUS_MISFIRES_1000REV_C3

  • Service 22DID 1148
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires / 1000 revolutions, cylinder 4 VIRTUS_MISFIRES_1000REV_C4

  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires counter:, cylinder 2 VIRTUS_MIS_CNT_2

  • Service 22DID 1482
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires counter:, cylinder 3 VIRTUS_MIS_CNT_3

  • Service 22DID 1480
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires counter:, cylinder 5 VIRTUS_MIS_CNT_5

  • Service 22DID 1483
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires per 1000 revolutions 4 VIRTUS_MIS_PER_1000_REVOLUTIONS_4_7E0

  • Service 22DID 114C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires per 1000 revolutions, cylinder 1, port injection VIRTUS_MIS_PER_1000_1

  • Service 22DID 426B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires per 1000 revolutions, cylinder 2 VIRTUS_MIS_PER_1000_2_7E0

  • Service 22DID 10F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires per 1000 revolutions, cylinder 2, port injection VIRTUS_MIS_PER_1000_2

  • Service 22DID 426C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires per 1000 revolutions, cylinder 3 VIRTUS_MIS_PER_1000_3_7E0

  • Service 22DID 10F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires per 1000 revolutions, cylinder 3, port injection VIRTUS_MIS_PER_1000_3

  • Service 22DID 426D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires per 1000 revolutions, cylinder 4, port injection VIRTUS_MIS_PER_1000_4

  • Service 22DID 426E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires total VIRTUS_MIS_TOT

  • Service 22DID 2904
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires total VIRTUS_MISFIRES_TOTAL

  • Service 22DID 1146
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 1 VIRTUS_MIS_1

  • Service 22DID 10F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 1 VIRTUS_MISFIRES_C1

  • Service 22DID 114F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 1,, variant 2 VIRTUS_MIS_VAR_2_1

  • Service 22DID 2966
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 2 VIRTUS_MIS_2

  • Service 22DID 10FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 2,, variant 2 VIRTUS_MIS_VAR_2

  • Service 22DID 2967
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 3 VIRTUS_MIS_3

  • Service 22DID 10F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 3 VIRTUS_MISFIRES_C3

  • Service 22DID 1150
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 3,, variant 2 VIRTUS_MIS_VAR_2_3

  • Service 22DID 2968
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 4 VIRTUS_MIS_4

  • Service 22DID 10F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 4,, variant 2 VIRTUS_MIS_VAR_2_4

  • Service 22DID 2969
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Mixture adaptation factor at partial load VIRTUS_MIXTURE_ADPT_FACTOR

  • Service 22DID 3996
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

N_32 VIRTUS_N_32

  • Service 22DID 117D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2018 to 2026.

NL_PRE, 0 VIRTUS_NL_PRE_0

  • Service 22DID 13F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2018 to 2026.

NL_PRE, 1 VIRTUS_NL_PRE_1

  • Service 22DID 13F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2018 to 2026.

NL_PRE, 2 VIRTUS_NL_PRE_2

  • Service 22DID 13F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2018 to 2026.

NL_PRE, 3 VIRTUS_NL_PRE_3

  • Service 22DID 13F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2018 to 2026.

Number of automatic engine starts VIRTUS_NUM_AUTOMATIC_ENG

  • Service 22DID 2999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Number of engine starts, manual VIRTUS_NUM_ENG_STARTS

  • Service 22DID 2998
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Number of injections VIRTUS_NUM_INJECTIONS

  • Service 22DID 430E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Number of times the permitted centrifugal oil temperature has been exceeded VIRTUS_NUM_TIMES_PERMITTED_T

  • Service 22DID 1154
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Number of warnings due to increased centrifugal oil temperature VIRTUS_NUM_WARN_HI_CENTRIF_T

  • Service 22DID 1155
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

NV energy requirement VIRTUS_NV_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2018 to 2026.

Oil ash limit VIRTUS_OIL_ASH_LIM

  • Service 22DID 1793
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2018 to 2026.

Oil ash residue VIRTUS_OIL_ASH_RESIDUE

  • Service 22DID 208A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×3.052e-7
Range
0 to 1310
Unit
Raw value

In testing for 2018 to 2026.

Oil ash residue VIRTUS_OIL_ASH_RESIDUE_7E0

  • Service 22DID 406C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2018 to 2026.

Oil ash residue VIRTUS_PQ35_OIL_ASH_RESIDUE

  • Service 22DID 178C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Oil dynamic average measurement VIRTUS_PQ35_OIL_DYN_AVG

  • Service 22DID 123F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2018 to 2026.

Oil fill level VIRTUS_PQ35_OIL_FILL_LEVEL

  • Service 22DID 2006
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.06
Range
-1966.08 to 1966.02 mm
Unit
mm

In testing for 2018 to 2026.

Oil last dynamic measurement VIRTUS_PQ35_OIL_DYN_LAST

  • Service 22DID 123C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2018 to 2026.

Oil level VIRTUS_OIL_LEVELConfirmed

  • Service 22DID 11BA
  • Module7E0
  • Every5 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

0x0000 = 0 → 02500 = 0 cm

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Oil level method 1 VIRTUS_OIL_LEVEL_METHOD_1

  • Service 22DID 1AF9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2018 to 2026.

Oil level method 2 VIRTUS_OIL_LEVEL_METHOD_2

  • Service 22DID 1AFA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2018 to 2026.

Oil level method 3 VIRTUS_OIL_LEVEL_METHOD_3

  • Service 22DID 1AFB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2018 to 2026.

Oil level test method 1 VIRTUS_OIL_LEVEL_TEST_1

  • Service 22DID 4E51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Oil level test method 2 VIRTUS_OIL_LEVEL_TEST_2

  • Service 22DID 4E52
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Oil level test method 3 VIRTUS_OIL_LEVEL_TEST_3

  • Service 22DID 4E53
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Oil level, average dynamic value VIRTUS_OIL_LEVEL_AVG

  • Service 22DID 15B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2018 to 2026.

Oil level, static measured VIRTUS_OIL_LEVEL_STATIC

  • Service 22DID 15A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2018 to 2026.

Oil level, static measurement VIRTUS_OIL_LEVEL_STATIC_7E0

  • Service 22DID 40CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−127
Range
-127 to 3968 mm
Unit
mm

In testing for 2018 to 2026.

Oil p VIRTUS_OIL_P

  • Service 22DID 25CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2018 to 2026.

Oil pressure actual VIRTUS_MQB_TCM_EOP_ACTUAL

  • Service 22DID 381D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 bar
Unit
bar

In testing for 2018 to 2026.

Oil pressure actual current VIRTUS_MQB_TCM_EOP_ACTUAL_I

  • Service 22DID 381E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2018 to 2026.

Oil pressure control valve activation pulse duty factor VIRTUS_OIL_P_CTRL_VLV

  • Service 22DID 25D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2018 to 2026.

Oil pressure control valve, activation pulse duty factor VIRTUS_OIL_P_CTRL_VLV_ACTIVATION

  • Service 22DID 4F97
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2018 to 2026.

Oil pressure sensor raw value VIRTUS_OIL_P_SENS_RAW

  • Service 22DID 4FBE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2018 to 2026.

Oil pressure sensor-piston cooling nozzle switch, status VIRTUS_OIL_P_SENS_PISTON

  • Service 22DID 15BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Oil pressure sensor, raw value VIRTUS_OIL_P_SENS_RAW_7E0

  • Service 22DID 1B02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Oil pressure switch activation, high pressure VIRTUS_OIL_P_SWITCH_P

  • Service 22DID 20A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Oil pressure switch for high pressure, closed VIRTUS_OIL_P_SWITCH_HIGH_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Oil pressure switch for low pressure, closed VIRTUS_OIL_P_SWITCH_LOW_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Oil pressure switch for piston-cooling jets, closed VIRTUS_OIL_P_SWITCH_PISTON

  • Service 22DID 4270
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Oil pressure switch valve activation VIRTUS_OIL_P_SWITCH_VLV

  • Service 22DID 13B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Oil pressure target VIRTUS_OIL_P_TGT

  • Service 22DID 4F70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 2018 to 2026.

Oil pressure target VIRTUS_OIL_P_TGT_7E0

  • Service 22DID 25CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2018 to 2026.

Oil pressure valve for piston cooling nozzles, control switch button ratio VIRTUS_OIL_P_VLV_PISTON

  • Service 22DID 2CD8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2018 to 2026.

Oil pressure valve switch, control VIRTUS_OIL_P_VLV_SWITCH

  • Service 22DID 11B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Oil pressure, actual value VIRTUS_OIL_P_ACT_7E0

  • Service 22DID 177D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2018 to 2026.

Oil pressure, actual value VIRTUS_OIL_P_ACT_7E0_2

  • Service 22DID 1B04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Oil pressure, actual value VIRTUS_OIL_P_ACT_7E0_2_7E0

  • Service 22DID 381D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2018 to 2026.

Oil temp 2 VIRTUS_PQ35_ENGINE_OIL_T_2

  • Service 22DID 179C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Oil temperature VIRTUS_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 10A7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2018 to 2026.

Oil temperature variant VIRTUS_PQ35_OIL_T_2Confirmed

  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

0xFFFA = 65530 → 6553010−273.1 = 6,279.9 °C

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Oil warning threshold VIRTUS_OIL_WARN_THR

  • Service 22DID 2007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mm
Unit
mm

In testing for 2018 to 2026.

Open cam shaft angle at quantity control valve VIRTUS_OPEN_CAM_SHFT_ANG

  • Service 22DID 10EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Outside temperature, from cabin sensor VIRTUS_AAT_CABINConfirmed

  • Service 22DID 260A
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x95 = 149 → 1492−50 = 24.5 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Overall energy balance VIRTUS_OVERALL_ENERGY

  • Service 22DID 2A17
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val×2120
Range
-8808038 to 8808037 Ah
Unit
Ah

In testing for 2018 to 2026.

Oxygen control, adaptation value at part. load VIRTUS_OXYGEN_CTRL_ADPT

  • Service 22DID 39A9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2018 to 2026.

Oxygen sensor 1 bank 1 ceramic temperature VIRTUS_OXYGEN_SNS_1_BANK_1_CERAMIC_T_7E0

  • Service 22DID 1290
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×234.3710000−273.15
Range
-273.15 to 1262.793 °C
Unit
°C

In testing for 2018 to 2026.

Oxygen sensor 1 bank 1 lambda value VIRTUS_PQ35_O2_SEN_1_LAMBDA

  • Service 22DID 113D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Number

In testing for 2018 to 2026.

Particle filter, field regeneration request status VIRTUS_PARTICLE_FLT_FIELD

  • Service 22DID 115B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Particle sensor, time in op.mode measurement VIRTUS_PARTICLE_SENS_TIME

  • Service 22DID 46D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 s
Unit
s

In testing for 2018 to 2026.

Pilot injection 1 duration VIRTUS_PQ35_PRE_INJ_1_DURATION

  • Service 22DID 14D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2018 to 2026.

Pilot injection 1 start position VIRTUS_PQ35_PRE_INJ_1_START

  • Service 22DID 14C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2018 to 2026.

Pilot injection 1, activation start VIRTUS_PRE_INJ_1_ACTIVATION

  • Service 22DID 12C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2018 to 2026.

Pilot injection 2 duration VIRTUS_PQ35_PRE_INJ_2_DURATION

  • Service 22DID 14D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2018 to 2026.

Pilot injection 2 start VIRTUS_PQ35_PRE_INJ_2_START

  • Service 22DID 14C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2018 to 2026.

Pilot injection 2, activation start VIRTUS_PRE_INJ_2_ACTIVATION

  • Service 22DID 12C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2018 to 2026.

Pilot injection 3 start VIRTUS_PRE_INJ_3_START

  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×219731000000
Range
-720 to 719 °
Unit
°

In testing for 2018 to 2026.

Pilot injection 3, activation duration VIRTUS_PRE_INJ_3_ACTIVATION

  • Service 22DID 121A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2018 to 2026.

Pilot injection 3, activation start VIRTUS_PRE_INJ_3_ACTIVATION_START

  • Service 22DID 121D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2018 to 2026.

Piston cooling nozzles, control VIRTUS_PISTON_COOLING

  • Service 22DID 16F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Piston-cooling jets, activation VIRTUS_PISTON_COOLING_JETS

  • Service 22DID 4286
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Port injection injections counter VIRTUS_PORT_INJ_INJECTIONS

  • Service 22DID 4268
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2018 to 2026.

Post injection 1 VIRTUS_POST_INJ_1

  • Service 22DID 081A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Post injection 1 VIRTUS_POST_INJ_1_7E0

  • Service 22DID 205D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2018 to 2026.

Post injection 1: quantity specified value VIRTUS_PQ35_POST_INJ_1_QTY_SPEC

  • Service 22DID 163C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2018 to 2026.

Post injection 2 VIRTUS_POST_INJ_2

  • Service 22DID 080C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Post injection 2 VIRTUS_POST_INJ_2_7E0

  • Service 22DID 205F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2018 to 2026.

Post injection 2: quantity specified value VIRTUS_PQ35_POST_INJ_2_QTY_SPEC

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2018 to 2026.

Post injection 3 VIRTUS_POST_INJ_3

  • Service 22DID 081B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Post injection 3 VIRTUS_POST_INJ_3_7E0

  • Service 22DID 20C0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2018 to 2026.

Post injection 3: quantity specified value VIRTUS_PQ35_POST_INJ_3_QTY_SPEC

  • Service 22DID 167D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2018 to 2026.

Post-injection 1 duration VIRTUS_PQ35_POST_INJ_1_DURATION

  • Service 22DID 14CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2018 to 2026.

Post-injection 1 start position VIRTUS_PQ35_POST_INJ_1_START

  • Service 22DID 11F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2018 to 2026.

Post-injection 2 duration VIRTUS_PQ35_POST_INJ_2_DURATION

  • Service 22DID 14CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2018 to 2026.

Post-injection 2 start position VIRTUS_PQ35_POST_INJ_2_START

  • Service 22DID 11F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2018 to 2026.

Post-injection 2, activation duration VIRTUS_POST_INJ_2_7E0_7E0

  • Service 22DID 121B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2018 to 2026.

Post-injection 3 activation duration VIRTUS_PQ35_POST_INJ_3_ACTIVATION_DURATION

  • Service 22DID 14CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2018 to 2026.

Post-injection 3 start position VIRTUS_PQ35_POST_INJ_3_START

  • Service 22DID 1131
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2018 to 2026.

Pressure before throttle valve - actual value VIRTUS_P_BEFORE_THROTTLE_ACT

  • Service 22DID 11EE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2018 to 2026.

Pressure before throttle valve - sensor measured VIRTUS_P_BEFORE_THROTTLE

  • Service 22DID 11EF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×21333546125
Range
0 to 2559.96
Unit
Raw value

In testing for 2018 to 2026.

Pressure sensor 1 temperature VIRTUS_MQB_DL382_P_SENSOR_1_T

  • Service 22DID 132A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2026.

Pressure sensor 2 temperature VIRTUS_MQB_DL382_P_SENSOR_2_T

  • Service 22DID 132B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2026.

Pressure supply actual pressure VIRTUS_MQB_DQ200_P_SUPPLY_ACTUAL_P

  • Service 22DID 1191
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Pressure supply actual pressure analog digital value VIRTUS_MQB_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUE

  • Service 22DID 102D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_1 VIRTUS_PSN_EDGE_REL_AD_CAM_1

  • Service 22DID 1184
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2018 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_2 VIRTUS_PSN_EDGE_REL_AD_CAM_2

  • Service 22DID 1185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2018 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_IN_1 VIRTUS_PSN_EDGE_REL_AD_CAM_SAVE_1

  • Service 22DID 1186
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2018 to 2026.

Radiator fan 1, commanded duty VIRTUS_RADIATOR_FAN_1_CMD

  • Service 22DID 109E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2018 to 2026.

Radiator fan 2, commanded duty VIRTUS_RADIATOR_FAN_2_CMD

  • Service 22DID 109C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2018 to 2026.

Radiator fan actual duty VIRTUS_CLIMATE_RAD_FAN_ACT_DUTYConfirmed

  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.4
Range
0 to 100 %
Unit
%

0x52 = 82 → 82×0.4 = 32.8 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Radiator fan commanded duty VIRTUS_CLIMATE_RAD_FAN_CMD_DUTYConfirmed

  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.4
Range
0 to 100 %
Unit
%

0x49 = 73 → 73×0.4 = 29.2 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Radiator outlet coolant temperature commanded VIRTUS_PQ35_RAD_COOL_T_CMD

  • Service 22DID 1111
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Radiator output coolant temp: actual VIRTUS_PQ35_RADIATOR_OUTPUT_COOLANT_T_ACTUAL

  • Service 22DID 1626
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Rated drive torque VIRTUS_RATED_DRIVE_TQ

  • Service 22DID 14A1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2018 to 2026.

Reached maximum temperature VIRTUS_PQ35_REACHED_MAXIMUM_T

  • Service 22DID 1117
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2026.

Reducing agent tank volume, act. value filtered VIRTUS_REDUCING_AGENT_TANK_ACT

  • Service 22DID 1A6C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131 L
Unit
L

In testing for 2018 to 2026.

Refrigerant pressure VIRTUS_CLIMATE_REFRIG_PConfirmed

  • Service 22DID 2605
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 bar
Unit
bar

0x2A = 42 → 425 = 8.4 bar

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Regeneration duration VIRTUS_REGEN_DUR

  • Service 22DID 39F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val60
Range
0 to 1092.25 min
Unit
min

In testing for 2018 to 2026.

Regulation factor total VIRTUS_PQ35_REG_FACTOR

  • Service 22DID 10E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
0 to 3.276 %
Unit
%

In testing for 2018 to 2026.

Relative load value VIRTUS_REL_LOAD

  • Service 22DID 1216
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234403081
Range
0 to 1536
Unit
Number

In testing for 2018 to 2026.

Relay for reserve coolant pump status VIRTUS_RELAY_RESERVE_CLT

  • Service 22DID 3999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Requested torque, amount for auxiliary units VIRTUS_REQ_TQ_AMOUNT

  • Service 22DID 10BE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Reserve torque VIRTUS_RESERVE_TQ

  • Service 22DID 106A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2018 to 2026.

Result of crankcase ventilation test, fail VIRTUS_RESULT_CRANKCASE_VENTILATION_TEST

  • Service 22DID 15CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Result of crankcase ventilation test, successful VIRTUS_RESULT_CRANKCASE

  • Service 22DID 15CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Route data, active VIRTUS_ROUTE_DATA_ACTIVE

  • Service 22DID 282C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Secondary air injection sensor 1 VIRTUS_SECONDARY_AIR_INJ_1

  • Service 22DID 3F68
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2018 to 2026.

SEG_AD_MMV_ER_H, 0 VIRTUS_SEG_AD_MMV_ER_H_0

  • Service 22DID 1138
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_H, 3 VIRTUS_SEG_AD_MMV_ER_H_3

  • Service 22DID 113B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_L, 0 VIRTUS_SEG_AD_MMV_ER_L_0

  • Service 22DID 113E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_L, 2 VIRTUS_SEG_AD_MMV_ER_L_2

  • Service 22DID 1140
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_L, 3 VIRTUS_SEG_AD_MMV_ER_L_3

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_MID, 0 VIRTUS_SEG_AD_MMV_ER_MID_0

  • Service 22DID 1132
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_MID, 1 VIRTUS_SEG_AD_MMV_ER_MID_1

  • Service 22DID 1133
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_MID, 2 VIRTUS_SEG_AD_MMV_ER_MID_2

  • Service 22DID 1134
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER, 2 VIRTUS_SEG_AD_MMV_ER_2

  • Service 22DID 112E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER, 3 VIRTUS_SEG_AD_MMV_ER_3

  • Service 22DID 112F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

Sensor for particle filter differential pressure, raw value VIRTUS_SENS_PARTICLE_FLT_P

  • Service 22DID 39E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Service limit VIRTUS_SERVICE_LIM

  • Service 22DID 20DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2026.

Service limit VIRTUS_SERVICE_LIM_7E0

  • Service 22DID 5851
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2026.

Service limit value VIRTUS_PQ35_SRV_LIM

  • Service 22DID 12CB
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2018 to 2026.

Smoke limit VIRTUS_PQ35_LIM_SMOKE

  • Service 22DID 1301
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Spark efficiency deviation at idle, maximum VIRTUS_SPARK_EFFICIENCY_DEV_MAX

  • Service 22DID 155B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Spark efficiency deviation at part load VIRTUS_SPARK_EFFICIENCY_DEV

  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×78.1100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Spark efficiency deviation at part load, maximum VIRTUS_SPARK_EFFICIENCY_DEV_PART_MAX

  • Service 22DID 155C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Stop signal switch VIRTUS_MQB_TCM_STOP_SIGNAL_SWITCH

  • Service 22DID 3800
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Sum of misfires counter VIRTUS_SUM_MIS_CNT

  • Service 22DID 10F2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Tank fill level diagnostic reference value VIRTUS_TANK_FILL_LEVEL

  • Service 22DID 51D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2018 to 2026.

TCO_1_ST VIRTUS_TCO_1_ST

  • Service 22DID 11D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2026.

TCO_1_SYS VIRTUS_TCO_1_SYS

  • Service 22DID 11CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2026.

Temperature after evaporator VIRTUS_CLIMATE_T_AFTER_EVAPConfirmed

  • Service 22DID 2612
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×0.333
Range
-42.624 to 42.291 °C
Unit
°C

0x01 = 1 → 1×0.333 = 0.333 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Temperature at air conditioner heat exchanger output VIRTUS_T_AC_HEAT_EXCHANGER

  • Service 22DID 1177
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2018 to 2026.

Temperature sensor for engine temperature management VIRTUS_T_SENS_ENG_T

  • Service 22DID 392A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Temperature sensor for engine temperature management, target value VIRTUS_T_SENS_ENG_T_TGT

  • Service 22DID 40E2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Test of catalytic converter status, canceled VIRTUS_TEST_CATALYTIC_CONV_STAT

  • Service 22DID 2927
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Test of catalytic converter, measured value VIRTUS_TEST_CATALYTIC_CONV

  • Service 22DID 2926
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535
Unit
Number

In testing for 2018 to 2026.

Thermostat, actual VIRTUS_THERMOSTAT_ACT

  • Service 22DID 4418
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122.0710000
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Thermostat, commanded VIRTUS_THERMOSTAT_CMD

  • Service 22DID 4417
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122.0710000
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Throttle regulator nominal value VIRTUS_THROTTLE_REGULATOR

  • Service 22DID 16C5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Throttle valve adapter position VIRTUS_PQ35_THROT_VALVE_ADAPT

  • Service 22DID 12FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

TI_1_MPI, 0 VIRTUS_TI_1_MPI_0

  • Service 22DID 13AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_1_MPI, 1 VIRTUS_TI_1_MPI_1

  • Service 22DID 13AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_1_MPI, 2 VIRTUS_TI_1_MPI_2

  • Service 22DID 13AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_1_MPI, 3 VIRTUS_TI_1_MPI_3

  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_1, 1 VIRTUS_TI_MES4_PLS_1_1

  • Service 22DID 13A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_1, 2 VIRTUS_TI_MES4_PLS_1_2

  • Service 22DID 13A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_1, 3 VIRTUS_TI_MES4_PLS_1_3

  • Service 22DID 13A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_2, 0 VIRTUS_TI_MES4_PLS_2_0

  • Service 22DID 13A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_2, 1 VIRTUS_TI_MES4_PLS_2_1

  • Service 22DID 13A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_2, 2 VIRTUS_TI_MES4_PLS_2_2

  • Service 22DID 13A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_2, 3 VIRTUS_TI_MES4_PLS_2_3

  • Service 22DID 13A7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_3, 0 VIRTUS_TI_MES4_PLS_3_0

  • Service 22DID 13A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_3, 1 VIRTUS_TI_MES4_PLS_3_1

  • Service 22DID 13A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_3, 2 VIRTUS_TI_MES4_PLS_3_2

  • Service 22DID 13AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_3, 3 VIRTUS_TI_MES4_PLS_3_3

  • Service 22DID 13AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

Time in after-run VIRTUS_TIME_AFTERRUN

  • Service 22DID 103A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2018 to 2026.

Time since last regeneration VIRTUS_TIME_SINCE_REGEN

  • Service 22DID 2089
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2018 to 2026.

Time since reset VIRTUS_TIME_SINCE_RESET

  • Service 22DID 103B
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 2018 to 2026.

Timing angle retardation cylinder 1 VIRTUS_PQ35_TIMING_ANGLE_RETARDATION_CYL_1

  • Service 22DID 200A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2018 to 2026.

Timing angle retardation cylinder 2 VIRTUS_PQ35_TIMING_ANGLE_RETARDATION_CYL_2

  • Service 22DID 200B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2018 to 2026.

Timing angle retardation cylinder 3 VIRTUS_PQ35_TIMING_ANGLE_RETARDATION_CYL_3

  • Service 22DID 200C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2018 to 2026.

Timing angle retardation cylinder 4 VIRTUS_PQ35_TIMING_ANGLE_RETARDATION_CYL_4

  • Service 22DID 200D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2018 to 2026.

Timing deviation after chain replacement, exhaust bank 1 VIRTUS_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1

  • Service 22DID 417D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Timing deviation after chain replacement, intake bank 1 VIRTUS_TIM_DEV_AFTER_CHAIN_1

  • Service 22DID 417B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Timing deviation after other repairs, intake bank 1 VIRTUS_TIM_DEV_AFTER_OTHER_1

  • Service 22DID 417F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Timing deviation after other repairs, intake bank 1 VIRTUS_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1

  • Service 22DID 4181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Timing deviation current value exhaust bank 1 VIRTUS_TIM_DEV_CURRENT_EXH_1

  • Service 22DID 4185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Timing deviation current value intake bank 1 VIRTUS_TIM_DEV_CURRENT_INT_1

  • Service 22DID 4183
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Torque converter: torque loss VIRTUS_TORQUE_CONVERTER_TORQUE_LOSS_7E1

  • Service 22DID 7053
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque factor VIRTUS_TQ_FACTOR

  • Service 22DID 2119
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Torque increase request from ESP VIRTUS_TQ_INCREASE_REQ_ESP

  • Service 22DID 1340
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque limit VIRTUS_PQ35_LIM_TRQ

  • Service 22DID 106B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque limitation VIRTUS_TORQUE_LIMITATION_7E1

  • Service 22DID 203F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque limitation VIRTUS_TQ_LIM

  • Service 22DID 107D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque limitation VIRTUS_TQ_LIM_7E0

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque limitation, clutch protection VIRTUS_TQ_LIM_CLU

  • Service 22DID 20A0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque loss adaptation VIRTUS_TQ_LOSS_ADPT

  • Service 22DID 2122
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque loss adaptation at idle VIRTUS_TQ_LOSS_ADPT_IDLE

  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque loss adaptation, A/C compressor VIRTUS_TQ_LOSS_ADPT_AC_COMP_7E0

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque reduction due to exhaust temperature VIRTUS_PQ35_TRQ_RED_EXH_T

  • Service 22DID 10E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
-3.2768 to 3.2767
Unit
Number

In testing for 2018 to 2026.

Torque reduction request from ESP VIRTUS_TQ_REDUCTION_REQ_ESP

  • Service 22DID 133F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque request, sum of auxiliary aggregate VIRTUS_TQ_REQ_SUM_AUXILIARY

  • Service 22DID 209B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque transmitting function, ratio VIRTUS_TQ_TRANSMITTING

  • Service 22DID 2105
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2018 to 2026.

Total mass of gasoline and ethyl alcohol in oil VIRTUS_TOT_MASS_GASOLINE

  • Service 22DID 1713
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.021333
Range
0 to 1398
Unit
Raw value

In testing for 2018 to 2026.

Transmission drag torque VIRTUS_TCM_DRAG_TQ

  • Service 22DID 1021
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2018 to 2026.

Transmission fluid temperature, calculated VIRTUS_ATF_T_CALCULATED_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 704E
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2026.

Transmission fluid temperature, dual-clutch VIRTUS_ATF_T_DUAL_CLU

  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, modeled maximum reached VIRTUS_ATF_T_MODELED_MAX_REACHED_7E1

  • Service 22DID 7051
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

In testing for 2018 to 2026.

Transmission torque losses VIRTUS_TCM_TQ_LOSSES

  • Service 22DID 1022
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2018 to 2026.

Turbine actuator 1 bank 1 activation VIRTUS_PQ35_TURB_ACT_1_B1

  • Service 22DID 117E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Turbine actuator 1 bank 1: activation VIRTUS_ACT

  • Service 22DID 112C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Upper adapted coupling point K1 from macro slip path adaptation VIRTUS_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPT

  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2018 to 2026.

Upper adapted coupling point K2 from macro slip path adaptation VIRTUS_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPT

  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2018 to 2026.

Valve lift system, result of last switch, intake VIRTUS_VLV_LIFT_SYSTEM

  • Service 22DID 16BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Valve lift system, valve lift, exhaust VIRTUS_VLV_LIFT_SYSTEM_VLV_LIFT

  • Service 22DID 16BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Valve lift system, valve lift, intake VIRTUS_VLV_LIFT_SYSTEM_VLV

  • Service 22DID 16BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Valve timing, the difference between the, actual and the set angle VIRTUS_VLV_TIM_DIFF_ACT_SET

  • Service 22DID 10EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×156.2510000
Range
-512 to 511 °
Unit
°

In testing for 2018 to 2026.

Variable valve timing, intake, bank 1, switch on VIRTUS_VARIABLE_VLV_TIM_INT_1

  • Service 22DID 127D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Wear index VIRTUS_PQ35_WEAR_IDX

  • Service 22DID 10E2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 m
Unit
m

In testing for 2018 to 2026.

Wear index %, 0=new engine VIRTUS_WEAR_INDEX_0_NEW_ENG

  • Service 22DID 20C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

DPF

Regeneration duration VIRTUS_PQ35_REGEN_DUR

  • Service 22DID 1347
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 min
Unit
min

In testing for 2018 to 2026.

Service regeneration status VIRTUS_PQ35_SRV_REGEN_STAT

  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

EGR

Exhaust gas recirculation 2: filter press loss, modeled VIRTUS_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_MODELED

  • Service 22DID 2AE1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−500
Range
-3776.8 to 2776.7
Unit
Raw value

In testing for 2018 to 2026.

Exhaust gas recirculation 2: filter press loss, simulated VIRTUS_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_SIMULATED

  • Service 22DID 2AE2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−500
Range
-3776.8 to 2776.7
Unit
Raw value

In testing for 2018 to 2026.

High pressure exhaust gas recirculation closing, variant 1 VIRTUS_PQ35_HIGH_P_EGR_CLOSING_VAR_1

  • Service 22DID F469
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

High pressure exhaust gas recirculation closing, variant 2 VIRTUS_PQ35_HIGH_P_EGR_CLOSING_VAR_2

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Fluids

Oil level, critical VIRTUS_OIL_CRIT

  • Service 22DID 11BB
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Oil level, maximum VIRTUS_OIL_MAX

  • Service 22DID 11C4
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 cm
Unit
cm

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Oil level, minimum VIRTUS_OIL_MIN

  • Service 22DID 11C5
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 cm
Unit
cm

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel

Activation of fuel pump electronics VIRTUS_ACTIVATION_FUEL_PMP

  • Service 22DID 2028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Counter of fuel entry in oil VIRTUS_CNT_FUEL_ENTRY_OIL

  • Service 22DID 399F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Error counter bad fuel VIRTUS_ERROR_CNT_BAD_FUEL

  • Service 22DID 44BB
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2018 to 2026.

Fuel consumption - actual drive cycle VIRTUS_FUEL_CONS_ACT_DRIVE

  • Service 22DID 1519
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2018 to 2026.

Fuel consumption per driving cycle VIRTUS_FUEL_CONS_PER

  • Service 22DID 51D6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2018 to 2026.

Fuel filter: water level sensor 1 VIRTUS_MQB_FUEL_FILTER_WATER_LEVEL_SENSOR_1

  • Service 22DID 197C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Fuel flow VIRTUS_FUEL_FLOW

  • Service 22DID 10A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 L
Unit
L

In testing for 2018 to 2026.

Fuel flow rate VIRTUS_PQ35_FUEL_FLOW

  • Service 22DID 111A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 L
Unit
L

In testing for 2018 to 2026.

Fuel high pressure, actual value VIRTUS_FUEL_HIGH_P_ACT

  • Service 22DID 2027
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2018 to 2026.

Fuel high pressure, control deviation VIRTUS_FUEL_HIGH_P_CTRL_DEV

  • Service 22DID 20BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 bar
Unit
bar

In testing for 2018 to 2026.

Fuel high pressure, specified value VIRTUS_FUEL_HIGH_P_SPEC

  • Service 22DID 293B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2018 to 2026.

Fuel injector time deviation, cylinder 1 VIRTUS_FUEL_INJ_TIME_DEV_1

  • Service 22DID 2000
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Fuel injector time deviation, cylinder 2 VIRTUS_FUEL_INJ_TIME_DEV_2

  • Service 22DID 207B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Fuel injector time deviation, cylinder 2 VIRTUS_FUEL_INJ_TIME_DEV_CYL_2

  • Service 22DID 21C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Fuel injector time deviation, cylinder 3 VIRTUS_FUEL_INJ_TIME_DEV_3

  • Service 22DID 2100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Fuel injector time deviation, cylinder 4 VIRTUS_FUEL_INJ_TIME_DEV_4

  • Service 22DID 2101
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Fuel level VIRTUS_FLI_7E0

  • Service 22DID 1008
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2018 to 2026.

Fuel level VIRTUS_PQ35_FUEL_LEVEL_7E0_2206

  • Service 22DID 2206
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2018 to 2026.

Fuel level input % VIRTUS_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Fuel level input, v1 VIRTUS_FUEL_LEVEL_INPUT_V1

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 14B4
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2018 to 2026.

Fuel level input, variant 2 VIRTUS_FLI_INPUT_VAR_2

  • Service 22DID 24FC
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2018 to 2026.

Fuel level variant VIRTUS_PQ35_FUEL_LVL_2

  • Service 22DID 100C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2018 to 2026.

Fuel low pressure, actual value VIRTUS_FUEL_LOW_P_ACT

  • Service 22DID 2025
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2018 to 2026.

Fuel low pressure, specified value VIRTUS_FUEL_LOW_P_SPEC

  • Service 22DID 2932
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2018 to 2026.

Fuel mass request, integral controller VIRTUS_FUEL_MASS_REQ_I_CTL

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10597500000
Range
-694 to 694
Unit
Raw value

In testing for 2018 to 2026.

Fuel mass request, proportional controller VIRTUS_FUEL_MASS_REQ_P_CTL

  • Service 22DID 1312
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10597500000
Range
-694 to 694
Unit
Raw value

In testing for 2018 to 2026.

Fuel metering valve VIRTUS_FUEL_METERING_VLV

  • Service 22DID 209A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Fuel mix correction coefficient VIRTUS_FUEL_MIX_CORR

  • Service 22DID 1710
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518−273.1
Range
-273.1 to -73.1003
Unit
Number

In testing for 2018 to 2026.

Fuel part from EVAP system VIRTUS_FUEL_PART_EVAP

  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×781100000
Range
-0.9996 to 0.9918
Unit
Number

In testing for 2018 to 2026.

Fuel pressure regulator position VIRTUS_PQ35_FUEL_P_REG

  • Service 22DID 11BF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Fuel pressure regulator valve: specified value rail pressure VIRTUS_SPEC_VALUE_RAIL_P

  • Service 22DID 121E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Fuel pressure, low actual VIRTUS_FUEL_P_LOW_ACT

  • Service 22DID 1AB8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2018 to 2026.

Fuel pump adaptation VIRTUS_FUEL_PMP_ADPT

  • Service 22DID 11C9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2018 to 2026.

Fuel pump specified value VIRTUS_FUEL_PMP_SPEC

  • Service 22DID 1109
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Fuel pump, commanded duty VIRTUS_FUEL_PMP_CMD_DUTY

  • Service 22DID 11A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0015258743
Range
0 to 99.99 %
Unit
%

In testing for 2018 to 2026.

Fuel rate VIRTUS_FUEL_RATEConfirmed

  • Service 22DID 113F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L/h
Unit
L/h

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Fuel rate difference, injector/sensor VIRTUS_FUEL_RATE_DIFF_INJ

  • Service 22DID 180A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×195315000000
Range
-127.9983 to 127.9944 L
Unit
L

In testing for 2018 to 2026.

Fuel rate, variant 2 VIRTUS_FUEL_RATE_VAR_2

  • Service 22DID 204C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2018 to 2026.

Fuel temperature VIRTUS_FUEL_T

  • Service 22DID 128A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Fuel temperature VIRTUS_FUEL_T_7E0

  • Service 22DID 203E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Fuel temperature VIRTUS_FUEL_T_7E0_2

  • Service 22DID 111C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2018 to 2026.

High fuel pressure control deviation VIRTUS_HIGH_FUEL_P_CONTROL_DEVIATION

  • Service 22DID 121F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

High fuel pressure, actual VIRTUS_HIGH_FUEL_P_ACT

  • Service 22DID 159F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2018 to 2026.

High fuel pressure, actual value VIRTUS_HIGH_FUEL_P_ACT_7E0

  • Service 22DID 4460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2018 to 2026.

High fuel pressure, commanded VIRTUS_HIGH_FUEL_P_CMD

  • Service 22DID 11D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2018 to 2026.

High fuel pressure, regulation error VIRTUS_HIGH_FUEL_P

  • Service 22DID 11D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2018 to 2026.

High fuel pressure, target VIRTUS_HIGH_FUEL_P_TGT

  • Service 22DID 111B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.76
Unit
Raw value

In testing for 2018 to 2026.

High pressure fuel pressure actual VIRTUS_PQ35_FUEL_P_HIGH

  • Service 22DID 1169
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2018 to 2026.

High pressure fuel pressure commanded VIRTUS_PQ35_FUEL_P_HIGH_CMD

  • Service 22DID 116A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2018 to 2026.

Long term fuel trim at idle VIRTUS_LONG_TERM_FUEL_TRIM_7E0

  • Service 22DID 110E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 %
Unit
%

In testing for 2018 to 2026.

Long term fuel trim at idle VIRTUS_LONG_TERM_FUEL_TRIM_IDLE_7E0

  • Service 22DID 4381
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2018 to 2026.

Long term fuel trim bank 1 VIRTUS_LONG_TERM_FUEL_TRIM_1

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2018 to 2026.

Long term fuel trim direct injection at load VIRTUS_LONG_TERM_FUEL_TRIM

  • Service 22DID 1779
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2018 to 2026.

Long term fuel trim port injection at load VIRTUS_LONG_TERM_FUEL_TRIM_PORT

  • Service 22DID 177B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2018 to 2026.

Low fuel pressure, actual VIRTUS_LOW_FUEL_P_ACT

  • Service 22DID 11C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2018 to 2026.

Low fuel pressure, commanded VIRTUS_LOW_FUEL_P_CMD

  • Service 22DID 11CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2018 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual VIRTUS_RAT_EVAPORATED_FUEL_ACT

  • Service 22DID 1711
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×781100000
Range
0 to 1.9915
Unit
Number

In testing for 2018 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum VIRTUS_RAT_EVAPORATED_FUEL_MAX

  • Service 22DID 1712
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×8310625
Range
0 to 1.992
Unit
Number

In testing for 2018 to 2026.

Short term fuel trim bank 1 VIRTUS_SHORT_TERM_FUEL_TRIM_1

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2018 to 2026.

Movement

A/C compressor speed VIRTUS_CLIMATE_A_C_COMP_SPDConfirmed

  • Service 22DID 2603
  • Module746 → 7B0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

0x14 = 20 → 20×100 = 2,000 rpm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Acceleration VIRTUS_ACCEL

  • Service 22DID 2116
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Acceleration VIRTUS_ACCEL_7E0

  • Service 22DID 10CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Acceleration VIRTUS_ACCELERATION

  • Service 22DID 1187
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Acceleration VIRTUS_ACCELERATION_29BIT_7E0

  • Service 22DID 12B0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Acceleration or deceleration mode VIRTUS_ACCEL_DECCELERATION

  • Service 22DID 2118
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Accelerator pedal limit VIRTUS_PQ35_LIM_ACCEL_PED

  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Accelerator pedal position VIRTUS_ACCEL_PEDAL_POS

  • Service 22DID 3804
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Accelerator pedal position VIRTUS_ACCEL_PEDAL_POS_7E1

  • Service 22DID F449
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Accelerator pedal sensor 1 VIRTUS_PQ35_ACCEL_PED_1

  • Service 22DID 1221
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2018 to 2026.

Accelerator pedal sensor 2 VIRTUS_PQ35_ACCEL_PED_2

  • Service 22DID 102E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2018 to 2026.

Accelerator pedal torque limit VIRTUS_ACCEL_PEDAL_TQ_LIM

  • Service 22DID 1059
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Accelerator position 1 VIRTUS_ACCEL_POS_1

  • Service 22DID F449
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Accelerator position 2 VIRTUS_ACCEL_POS_2

  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Aux. hydraulic pump RPM VIRTUS_AUX_HYDRAULIC_PMP_RPM

  • Service 22DID 70D6
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2018 to 2026.

Camshaft speed VIRTUS_CAM_SPD

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2018 to 2026.

Camshaft speed VIRTUS_CAM_SPD_7E0

  • Service 22DID 1092
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2018 to 2026.

Camshaft speed VIRTUS_PQ35_CAMS_SPD

  • Service 22DID 133B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.3
Range
-9830.4 to 9830.1 rpm
Unit
rpm

In testing for 2018 to 2026.

Compressor speed VIRTUS_COMP_SPD

  • Service 22DID 46E1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2018 to 2026.

Crankshaft speed, RPM VIRTUS_CRANK_SPD_RPM

  • Service 22DID 206E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2018 to 2026.

Engine RPM VIRTUS_RPM

  • Service 22DID 16F3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

In testing for 2018 to 2026.

Engine RPM VIRTUS_RPM_7E0

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 7000 rpm
Unit
rpm

In testing for 2018 to 2026.

Engine RPM at idle required VIRTUS_ENGINE_RPM_AT_IDLE_REQUIRED_7E0

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2018 to 2026.

Front left wheel speed VIRTUS_FL_VSS_V2Confirmed

  • Service 22DID 1800
  • Module713 → 77D
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.

Front left wheel speed VIRTUS_TIRE_FL_SPD

  • Service 22DID 2B1B
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Front right wheel speed VIRTUS_FR_VSS_V2Confirmed

  • Service 22DID 1801
  • Module713 → 77D
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.

Front right wheel speed VIRTUS_TIRE_FR_SPD

  • Service 22DID 2B1C
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Front right wheel speed VIRTUS_TIRE_FR_SPD_V3Confirmed

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.

Idle speed specified rpm VIRTUS_IDLE_SPD_SPEC_RPM

  • Service 22DID 4056
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2018 to 2026.

Injection speed injector 0 VIRTUS_INJ_SPD_INJ_0

  • Service 22DID 10A4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2018 to 2026.

Injection speed injector 1 VIRTUS_INJ_SPD_INJ_1

  • Service 22DID 10A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2018 to 2026.

Injection speed injector 2 VIRTUS_INJ_SPD_INJ_2

  • Service 22DID 10A6
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2018 to 2026.

Injection speed injector 3 VIRTUS_INJ_SPD_INJ_3

  • Service 22DID 10A8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2018 to 2026.

Input shaft speed 1 VIRTUS_INPUT_SHFT_SPD_1

  • Service 22DID 70E0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 7000 rpm
Unit
rpm

In testing for 2018 to 2026.

Input shaft speed 2 VIRTUS_INPUT_SHFT_SPD_2

  • Service 22DID 70E1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 7000 rpm
Unit
rpm

In testing for 2018 to 2026.

Lateral acceleration VIRTUS_LATERAL_ACCEL

  • Service 22DID 1644
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Lateral acceleration, raw value VIRTUS_LATERAL_ACCEL_RAW

  • Service 22DID 15D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Longitudinal acceleration VIRTUS_LONGITUDINAL_ACCEL_7E0

  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Longitudinal acceleration, raw value VIRTUS_LONGITUDINAL_ACCEL

  • Service 22DID 15CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Misfires per 1000 rpm, all cylinders VIRTUS_MIS_PER_1000_RPM_ALL

  • Service 22DID 148B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires per 1000 rpm:, cylinder 3 VIRTUS_MIS_PER_1000_RPM_3

  • Service 22DID 1486
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires per 1000 rpm:, cylinder 5 VIRTUS_MIS_PER_1000_RPM_5

  • Service 22DID 1489
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires/1000 rpm, cylinder 1 VIRTUS_MISFIRES_1000_RPM_C1_7E0

  • Service 22DID 291D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires/1000 rpm, cylinder 2 VIRTUS_MISFIRES_1000_RPM_C2_7E0

  • Service 22DID 2920
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires/1000 rpm, cylinder 3 VIRTUS_MISFIRES_1000_RPM_C3_7E0

  • Service 22DID 291E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires/1000 rpm, cylinder 4 VIRTUS_MISFIRES_1000_RPM_C4_7E0

  • Service 22DID 291F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Mixture adaptation factor at idle speed VIRTUS_MIXTURE_ADPT_FACTOR_IDLE

  • Service 22DID 3997
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Rear left wheel speed VIRTUS_RL_VSS_V2Confirmed

  • Service 22DID 1802
  • Module713 → 77D
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.

Rear left wheel speed VIRTUS_TIRE_RL_SPD

  • Service 22DID 2B1D
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Rear left wheel speed VIRTUS_TIRE_RL_SPD_V3Confirmed

  • Service 22DID 1004
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

0x0008 = 8 → 810 = 0.8 km/h

Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.

Rear right wheel speed VIRTUS_RR_VSS_V2Confirmed

  • Service 22DID 1803
  • Module713 → 77D
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.

Rear right wheel speed VIRTUS_TIRE_RR_SPD

  • Service 22DID 2B1E
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Reducing agent pump, differential speed calculated VIRTUS_REDUCING_AGENT_PMP

  • Service 22DID 18CC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2018 to 2026.

Specified idle RPM VIRTUS_MQB_DQ250_SPECIFIED_IDLE_RPM

  • Service 22DID 3871
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

In testing for 2018 to 2026.

Speed ​​output VIRTUS_MQB_DQ250_SPD_OUTPUT

  • Service 22DID 1009
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

In testing for 2018 to 2026.

Transmission input shaft speed VIRTUS_PQ35_TRANS_IN_SPD

  • Service 22DID 11F1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2018 to 2026.

Transmission input speed VIRTUS_MQB_TCM_TRANSMISSION_INPUT_SPD_7E1_380A

  • Service 22DID 380A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2018 to 2026.

Transmission output speed VIRTUS_MQB_TCM_TRANSMISSION_OUTPUT_SPD_7E1_380B

  • Service 22DID 380B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2018 to 2026.

Vehicle speed VIRTUS_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Vehicle speed VIRTUS_VSS_7E1

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2018 to 2026.

Vehicle speed ESP VIRTUS_VSS_ESP

  • Service 22DID 1005
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2018 to 2026.

Vehicle speed from transmission VIRTUS_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSION

  • Service 22DID 100A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 km/h
Unit
km/h

In testing for 2018 to 2026.

Vehicle speed, HR VIRTUS_VSS_HR

  • Service 22DID 2106
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2018 to 2026.

Yaw acceleration, raw value VIRTUS_YAW_ACCEL_RAW

  • Service 22DID 15D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Stats

Driving time, eco VIRTUS_DRIVE_TIME_ECO

Value may be wrong, needs more validation. Proportion of time spent driving in eco mode

  • Service 22DID 0303
  • Module7E1 → 7E9
  • Every900 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Driving time, manual VIRTUS_DRIVE_TIME_MANUAL

Value may be wrong, needs more validation. Proportion of time spent driving in manual mode

  • Service 22DID 0305
  • Module7E1 → 7E9
  • Every900 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Driving time, sport VIRTUS_DRIVE_TIME_SPORT

Value may be wrong, needs more validation. Proportion of time spent driving in sport mode

  • Service 22DID 0304
  • Module7E1 → 7E9
  • Every900 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Total drive time VIRTUS_DRIVE_TIME

  • Service 22DID 0302
  • Module7E1 → 7E9
  • Every900 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 h
Unit
h

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Tires

Entire energy throughput VIRTUS_ENTIRE_ENERGY

  • Service 22DID 2A18
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val10
Range
-838860 to 838860 Ah
Unit
Ah

In testing for 2018 to 2026.

Front left flat tire indicator VIRTUS_TPMS_FR_L_FLAT_TIRE_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 296 to 303 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x0B = 11 → 11

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Front left tire pressure diffusion indicator VIRTUS_TPMS_FR_L_TIRE_P_DIFF_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 264 to 271 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x09 = 9 → 9

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Front left wheel speed VIRTUS_FL_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2018 to 2026.

Front right flat tire indicator VIRTUS_TPMS_FR_R_FLAT_TIRE_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 304 to 311 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x50 = 80 → 80

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Front right tire pressure diffusion indicator VIRTUS_TPMS_FR_R_TIRE_P_DIFF_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 272 to 279 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x06 = 6 → 6

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Front right wheel speed VIRTUS_FR_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2018 to 2026.

Rear left flat tire indicator VIRTUS_TPMS_RR_L_FLAT_TIRE_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 312 to 319 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x05 = 5 → 5

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Rear left tire pressure diffusion indicator VIRTUS_TPMS_RR_L_TIRE_P_DIFF_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 280 to 287 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x10 = 16 → 16

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Rear left wheel speed VIRTUS_RL_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2018 to 2026.

Rear right flat tire indicator VIRTUS_TPMS_RR_R_FLAT_TIRE_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Rear right tire pressure diffusion indicator VIRTUS_TPMS_RR_R_TIRE_P_DIFF_INDConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 288 to 295 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x7F = 127 → 127

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Rear right wheel speed VIRTUS_RR_WHL_SPD_713

  • Service 22DID 03E8
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2018 to 2026.

Steering wheel angle VIRTUS_STEER_WHEEL_ANGLE_ABS

  • Service 22DID 1804
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val×0.4375
Range
-14336 to 14335.5625 °
Unit
°

In testing for 2018 to 2026.

Steering wheel temperature VIRTUS_STEER_WHL_T

  • Service 22DID 5505
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2018 to 2026.

Tire pressure monitoring available? VIRTUS_TPMS_AVAILConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Transmission

Actual position clutch 1 duty cycle factor 1 VIRTUS_MQB_DQ200_ACTUAL_POS_CLUTCH_1_DUTY_CYCLE_FACTOR_1

  • Service 22DID 3832
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Actual position clutch 1 duty cycle factor 2 VIRTUS_MQB_DQ200_ACTUAL_POS_CLUTCH_1_DUTY_CYCLE_FACTOR_2

  • Service 22DID 3833
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Actual position clutch 2 duty cycle factor 1 VIRTUS_MQB_DQ200_ACTUAL_POS_CLUTCH_2_DUTY_CYCLE_FACTOR_1

  • Service 22DID 383B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Actual position clutch 2 duty cycle factor 2 VIRTUS_MQB_DQ200_ACTUAL_POS_CLUTCH_2_DUTY_CYCLE_FACTOR_2

  • Service 22DID 383C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Actual position of gear actuator a VIRTUS_MQB_DQ250_ACUTAL_POS_GEAR_POSER_A

  • Service 22DID 3852
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Actual position of gear actuator b VIRTUS_MQB_DQ250_ACUTAL_POS_GEAR_POSER_B

  • Service 22DID 385A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Actual position of gear actuator c VIRTUS_MQB_DQ250_ACUTAL_POS_GEAR_POSER_C

  • Service 22DID 3862
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Actual position of gear actuator d VIRTUS_MQB_DQ250_ACUTAL_POS_GEAR_POSER_D

  • Service 22DID 386A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Adaptation counter PF lockup clutch VIRTUS_ADPT_CNT_PF_LOCKUP

  • Service 22DID 1103
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Adaptation counter, clutch a VIRTUS_ADPT_CNT_CLU

  • Service 22DID 7085
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Adaptation counter, clutch b VIRTUS_ADPT_CNT_CLU_B

  • Service 22DID 7089
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Adaptation counter, clutch c VIRTUS_ADPT_CNT_CLU_C

  • Service 22DID 708D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Adaptation counter, clutch d VIRTUS_ADPT_CNT_CLU_D

  • Service 22DID 7091
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Adaptation counter, clutch e VIRTUS_ADPT_CNT_CLU_E

  • Service 22DID 7095
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Adaptation counter, fast fill time, clutch a VIRTUS_ADPT_CNT_FAST_FILL

  • Service 22DID 7087
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Adaptation counter, fast fill time, clutch b VIRTUS_ADPT_CNT_FAST_FILL_B

  • Service 22DID 708B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Adaptation counter, fast fill time, clutch c VIRTUS_ADPT_CNT_FAST_FILL_C

  • Service 22DID 708F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Adaptation counter, fast fill time, clutch d VIRTUS_ADPT_CNT_FAST_FILL_D

  • Service 22DID 7093
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Adaptation counter, fast fill time, clutch e VIRTUS_ADPT_CNT_FAST_FILL_E

  • Service 22DID 7097
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Adaptation counter, torque converter lockup clutch VIRTUS_ADPT_CNT_TSF_LOCKUP

  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Adaptation fill time, torque converter lockup clutch VIRTUS_ADPT_INFLATION_TIME

  • Service 22DID 1100
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 ms
Unit
ms

In testing for 2018 to 2026.

Adaptation inflation current PF lockup clutch VIRTUS_ADPT_INFLATION

  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 2018 to 2026.

Automatic transmission input speed VIRTUS_AT_INPUT_SPEED

  • Service 22DID 2102
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2018 to 2026.

Automatic transmission output speed VIRTUS_AT_OUTPUT_SPEED

  • Service 22DID 2103
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2018 to 2026.

Clutch 0 commanded pressure offset VIRTUS_MQB_DL382_CLUTCH_0_CMD_P_OFFSET

  • Service 22DID 1426
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 absolute pressure VIRTUS_MQB_DL382_CLUTCH_1_ABSOLUTE_P

  • Service 22DID 13CC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 actual pressure VIRTUS_PQ35_CLUTCH_1_ACTUAL_P

  • Service 22DID 38EB
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 actual pressure raw value VIRTUS_PQ35_DL382_CLUTCH_1_ACTUAL_P_RAW_VALUE

  • Service 22DID 10F9
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 adaptation basic characteristic point 0 moment VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_0_MOMENT

  • Service 22DID 1058
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Clutch 1 adaptation basic characteristic point 0 position VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_0_POS

  • Service 22DID 1057
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 adaptation basic characteristic point 1 moment VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_1_MOMENT

  • Service 22DID 105A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Clutch 1 adaptation basic characteristic point 1 position VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_1_POS

  • Service 22DID 1059
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 adaptation basic characteristic point 2 moment VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_2_MOMENT

  • Service 22DID 105C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Clutch 1 adaptation basic characteristic point 2 position VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_2_POS

  • Service 22DID 105B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 adaptation basic characteristic point 3 moment VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_3_MOMENT

  • Service 22DID 105E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Clutch 1 adaptation basic characteristic point 3 position VIRTUS_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_3_POS

  • Service 22DID 105D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 adaptation basic characteristics point 0 position VIRTUS_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_0_POS

  • Service 22DID 38AE
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 1 adaptation basic characteristics point 1 position VIRTUS_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_1_POS

  • Service 22DID 38AF
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 1 adaptation basic characteristics point 2 position VIRTUS_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_2_POS

  • Service 22DID 7000
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 1 adaptation basic characteristics point 3 position VIRTUS_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_3_POS

  • Service 22DID 7001
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 1 adaptation clutch end position closed VIRTUS_MQB_DQ200_CLUTCH_1_ADAPT_CLUTCH_END_POS_CLOSED

  • Service 22DID 38FF
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 1 adaptation clutch end position open VIRTUS_MQB_DQ200_CLUTCH_1_ADAPT_CLUTCH_END_POS_OPEN

  • Service 22DID 38FE
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 1 characteristic curve shift VIRTUS_PQ35_CLUTCH_1_CHAR_CURVE_SHIFT

  • Service 22DID 1063
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.11 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 1 commanded pressure VIRTUS_PQ35_CLUTCH_1_CMD_P

  • Service 22DID 38EC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 failed adaptations counter VIRTUS_PQ35_CLUTCH_1_FAILED_ADAPTS_COUNTER

  • Service 22DID 10CC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Clutch 1 friction value correction factor VIRTUS_PQ35_CLUTCH_1_FRICTION_VALUE_CORRECTION_FACTOR

  • Service 22DID 1062
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.09766
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Clutch 1 lower adaptation point VIRTUS_CLU_1_LO_ADPT_POINT

  • Service 22DID 1120
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 nominal pressure VIRTUS_CLU_1_NOMINAL_P

  • Service 22DID 125C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 pressure VIRTUS_MQB_DL382_CLUTCH_1_P

  • Service 22DID 214C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 protection function engaged quantity VIRTUS_PQ35_CLUTCH_1_PROT_ENGAGED_QTY

  • Service 22DID 1069
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2018 to 2026.

Clutch 1 successful adaptations counter VIRTUS_PQ35_CLUTCH_1_SUCCESSFUL_ADAPTS_COUNTER

  • Service 22DID 10C9
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Clutch 1 upper adaptation point VIRTUS_CLU_1_HI_ADPT_POINT

  • Service 22DID 1124
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 1 valve current: actual VIRTUS_MQB_DQ250_CLUTCH_1_VALVE_I_ACTUAL

  • Service 22DID 3835
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

In testing for 2018 to 2026.

Clutch 1 valve current: specified VIRTUS_MQB_DQ250_CLUTCH_1_VALVE_I_SPECIFIED

  • Service 22DID 3834
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

In testing for 2018 to 2026.

Clutch 2 absolute pressure VIRTUS_MQB_DL382_CLUTCH_2_ABSOLUTE_P

  • Service 22DID 13CD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 actual pressure VIRTUS_PQ35_CLUTCH_2_ACTUAL_P

  • Service 22DID 38EA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 actual pressure raw value VIRTUS_PQ35_DL382_CLUTCH_2_ACTUAL_P_RAW_VALUE

  • Service 22DID 10FA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 actual torque VIRTUS_MQB_TCM_CLUTCH_2_ACTUAL_TORQUE

  • Service 22DID 3839
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Clutch 2 adaptation basic characteristic point 0 moment VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_0_MOMENT

  • Service 22DID 106D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Clutch 2 adaptation basic characteristic point 0 position VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_0_POS

  • Service 22DID 106C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 adaptation basic characteristic point 1 moment VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_1_MOMENT

  • Service 22DID 106F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Clutch 2 adaptation basic characteristic point 1 position VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_1_POS

  • Service 22DID 106E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 adaptation basic characteristic point 2 moment VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_2_MOMENT

  • Service 22DID 1071
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Clutch 2 adaptation basic characteristic point 2 position VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_2_POS

  • Service 22DID 1070
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 adaptation basic characteristic point 3 moment VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_3_MOMENT

  • Service 22DID 1073
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Clutch 2 adaptation basic characteristic point 3 position VIRTUS_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_3_POS

  • Service 22DID 1072
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 adaptation basic characteristics point 0 position VIRTUS_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_0_POS

  • Service 22DID 38FA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 2 adaptation basic characteristics point 1 position VIRTUS_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_1_POS

  • Service 22DID 38FB
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 2 adaptation basic characteristics point 2 position VIRTUS_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_2_POS

  • Service 22DID 38FC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 2 adaptation basic characteristics point 3 position VIRTUS_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_3_POS

  • Service 22DID 38FD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 2 adaptation clutch end position closed VIRTUS_MQB_DQ200_CLUTCH_2_ADAPT_CLUTCH_END_POS_CLOSED

  • Service 22DID 38AB
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 2 adaptation clutch end position open VIRTUS_MQB_DQ200_CLUTCH_2_ADAPT_CLUTCH_END_POS_OPEN

  • Service 22DID 38AA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 2 adaptation end position closed VIRTUS_PQ35_CLUTCH_2_ADAPT_END_POS_CLOSED

  • Service 22DID 1075
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 adaptation end position opened VIRTUS_PQ35_CLUTCH_2_ADAPT_END_POS_OPENED

  • Service 22DID 1074
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 characteristic curve shift VIRTUS_PQ35_CLUTCH_2_CHAR_CURVE_SHIFT

  • Service 22DID 1078
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.11 mm
Unit
mm

In testing for 2018 to 2026.

Clutch 2 commanded pressure VIRTUS_PQ35_CLUTCH_2_CMD_P

  • Service 22DID 38ED
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 failed adaptations counter VIRTUS_PQ35_CLUTCH_2_FAILED_ADAPTS_COUNTER

  • Service 22DID 10ED
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Clutch 2 friction value correction factor VIRTUS_MQB_DQ200_CLUTCH_2_FRICTION_VALUE_CORRECTION_FACTOR

  • Service 22DID 1077
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.09766
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Clutch 2 lower adaptation point VIRTUS_CLU_2_LO_ADPT_POINT

  • Service 22DID 1121
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 pressure VIRTUS_MQB_DL382_CLUTCH_2_P

  • Service 22DID 214D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 protection function engaged quantity VIRTUS_PQ35_CLUTCH_2_PROT_ENGAGED_QTY

  • Service 22DID 107E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2018 to 2026.

Clutch 2 successful adaptations counter VIRTUS_PQ35_CLUTCH_2_SUCCESSFUL_ADAPTS_COUNTER

  • Service 22DID 10EA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Clutch 2 upper adaptation point VIRTUS_CLU_2_HI_ADPT_POINT

  • Service 22DID 1125
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2018 to 2026.

Clutch 2 valve current: actual VIRTUS_MQB_DQ250_CLUTCH_2_VALVE_I_ACTUAL

  • Service 22DID 383E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

In testing for 2018 to 2026.

Clutch 2 valve current: specified VIRTUS_MQB_DQ250_CLUTCH_2_VALVE_I_SPECIFIED

  • Service 22DID 383D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

In testing for 2018 to 2026.

Clutch adaptation values initial kill point 0 for K1 VIRTUS_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K1

  • Service 22DID 1156
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2018 to 2026.

Clutch adaptation values initial kill point 0 for K2 VIRTUS_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K2

  • Service 22DID 1157
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2018 to 2026.

Clutch adaptation values lower current point adaptation K1 VIRTUS_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K1

  • Service 22DID 1158
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2018 to 2026.

Clutch adaptation values lower current point adaptation K2 VIRTUS_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K2

  • Service 22DID 1159
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2018 to 2026.

Clutch kiss point rapid adaptation remaining VIRTUS_PQ35_CLUTCH_KISSPOINT_RAPID_ADAPT_REMAINING

  • Service 22DID 1711
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2018 to 2026.

Clutch overheating, clutch VIRTUS_CLU_OVERHEATING_CLU

  • Service 22DID 17FD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Clutch temperature VIRTUS_CLU_T

  • Service 22DID 1259
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2026.

Correction values for main press adaptation: high press on clutch 1 VIRTUS_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_1

  • Service 22DID 1181
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Correction values for main press adaptation: low press on clutch 1 VIRTUS_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_1

  • Service 22DID 1180
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Correction values for main pressure adaptation high pressure on clutch 2 VIRTUS_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_2

  • Service 22DID 1183
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Correction values for main pressure adaptation low pressure on clutch 2 VIRTUS_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_2

  • Service 22DID 1182
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2018 to 2026.

Current gear VIRTUS_CURRENT_GEAR

  • Service 22DID 3EDE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2018 to 2026.

Current gear VIRTUS_GEARConfirmed

The automatic transmission gear.

  • Service 22DID 210F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x06 = 6 → 6

States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear

Confirmed for 2024. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022.

Current gear VIRTUS_MQB_TCM_I_GEAR_DQ200

  • Service 22DID 3816
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−1
Range
-1 to 254
Unit
Number

In testing for 2018 to 2026.

Current gear VIRTUS_PQ35_GEAR

  • Service 22DID 100D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2018 to 2026.

Current lower pressure point clutch 1 from current to pressure adaptation VIRTUS_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT

  • Service 22DID 1130
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2018 to 2026.

Current lower pressure point clutch 2 from current to pressure adaptation VIRTUS_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT

  • Service 22DID 1132
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2018 to 2026.

Current N371 pressure control valve 6 lock-up clutch VIRTUS_CURRENT_N371_P_CTRL_6

  • Service 22DID 1029
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2018 to 2026.

Current upper pressure point clutch 1 from current to pressure adaptation VIRTUS_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT

  • Service 22DID 1131
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2018 to 2026.

Current upper pressure point clutch 2 from current to pressure adaptation VIRTUS_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT

  • Service 22DID 1133
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2018 to 2026.

Driving strategy mountain factor VIRTUS_PQ35_DRIVING_STRATEGY_MOUNTAIN_FACTOR

  • Service 22DID 1018
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Driving strategy sport factor VIRTUS_PQ35_DRIVING_STRATEGY_SPORT_FACTOR

  • Service 22DID 1019
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1700255
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Dynamic shift program VIRTUS_DYNAMIC_SHIFT

  • Service 22DID 2115
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Early ignition counter for oxygen shift, cylinder 1 VIRTUS_EARLY_IGN_CNT_OXYGEN_1

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter for oxygen shift, cylinder 2 VIRTUS_EARLY_IGN_CNT_OXYGEN_2

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter for oxygen shift, cylinder 3 VIRTUS_EARLY_IGN_CNT_OXYGEN_3

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter for oxygen shift, cylinder 4 VIRTUS_EARLY_IGN_CNT_OXYGEN_4

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Engaged position side a gear selector 1-3 VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_1_3

  • Service 22DID 1138
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Engaged position side a gear selector 2-4 VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_2_4

  • Service 22DID 1139
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Engaged position side a gear selector 5 and neutral VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_5_N

  • Service 22DID 113A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Engaged position side a gear selector 6 and reverse VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_6_R

  • Service 22DID 113B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Engaged position side b gear selector 1-3 VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_1_3

  • Service 22DID 1144
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Engaged position side b gear selector 2-4 VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_2_4

  • Service 22DID 1145
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Engaged position side b gear selector 5 and neutral VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_5_N

  • Service 22DID 1146
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Engaged position side b gear selector 6 and reverse VIRTUS_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_6_R

  • Service 22DID 1147
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Engine specified torque during transmission intervention VIRTUS_ENG_SPEC_TQ_DURING

  • Service 22DID 2110
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2018 to 2026.

Fast fill time, clutch a VIRTUS_FAST_FILL_TIME_CLU

  • Service 22DID 7086
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2018 to 2026.

Fast fill time, clutch b VIRTUS_FAST_FILL_TIME_CLU_B

  • Service 22DID 708A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2018 to 2026.

Fast fill time, clutch c VIRTUS_FAST_FILL_TIME_CLU_C

  • Service 22DID 708E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2018 to 2026.

Fast fill time, clutch d VIRTUS_FAST_FILL_TIME_CLU_D

  • Service 22DID 7092
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2018 to 2026.

Fast fill time, clutch e VIRTUS_FAST_FILL_TIME_CLU_E

  • Service 22DID 7096
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2018 to 2026.

Fill pressure, clutch a VIRTUS_FILL_P_CLU

  • Service 22DID 7084
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2018 to 2026.

Fill pressure, clutch b VIRTUS_FILL_P_CLU_B

  • Service 22DID 7088
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2018 to 2026.

Fill pressure, clutch c VIRTUS_FILL_P_CLU_C

  • Service 22DID 708C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2018 to 2026.

Fill pressure, clutch d VIRTUS_FILL_P_CLU_D

  • Service 22DID 7090
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2018 to 2026.

Fill pressure, clutch e VIRTUS_FILL_P_CLU_E

  • Service 22DID 7094
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2018 to 2026.

Gear VIRTUS_GEAR_V2

  • Service 22DID 14CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Gear actuator adaptation engaged position G1 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G1

  • Service 22DID 1082
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation engaged position G2 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G2

  • Service 22DID 1090
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation engaged position G3 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G3

  • Service 22DID 1086
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation engaged position G4 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G4

  • Service 22DID 1094
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation engaged position G5 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G5

  • Service 22DID 109E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation engaged position G6 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G6

  • Service 22DID 10AC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation engaged position G7 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G7

  • Service 22DID 10A2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation engaged position GR VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_GR

  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation synchronization position G1 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G1

  • Service 22DID 1083
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation synchronization position G2 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G2

  • Service 22DID 1091
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation synchronization position G3 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G3

  • Service 22DID 1085
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation synchronization position G4 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G4

  • Service 22DID 1093
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation synchronization position G5 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G5

  • Service 22DID 109F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation synchronization position G6 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G6

  • Service 22DID 10AD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation synchronization position G7 VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G7

  • Service 22DID 10A1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear actuator adaptation synchronization position reverse VIRTUS_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_GR

  • Service 22DID 10AF
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear selector a adaptation neutral position VIRTUS_PQ35_GANGSTELLER_A_ADAPT_NEUTRALPOS

  • Service 22DID 1084
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear selector b adaptation neutral position VIRTUS_PQ35_GANGSTELLER_B_ADAPT_NEUTRALPOS

  • Service 22DID 1092
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear selector c adaptation neutral position VIRTUS_PQ35_GANGSTELLER_C_ADAPT_NEUTRALPOS

  • Service 22DID 10A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear selector d adaptation neutral position VIRTUS_PQ35_GANGSTELLER_D_ADAPT_NEUTRALPOS

  • Service 22DID 10AE
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2018 to 2026.

Gear selector synchronous position g and reverse VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G_R

  • Service 22DID 117F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2018 to 2026.

Gear selector synchronous position G1 VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G1

  • Service 22DID 1179
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2018 to 2026.

Gear selector synchronous position G2 VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G2

  • Service 22DID 117A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2018 to 2026.

Gear selector synchronous position G3 VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G3

  • Service 22DID 117B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2018 to 2026.

Gear selector synchronous position G4 VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G4

  • Service 22DID 117C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2018 to 2026.

Gear selector synchronous position G5 VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G5

  • Service 22DID 117D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2018 to 2026.

Gear selector synchronous position G6 VIRTUS_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G6

  • Service 22DID 117E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2018 to 2026.

Input shaft 1 VIRTUS_MQB_INPUT_SHAFT_1

  • Service 22DID 380C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2018 to 2026.

Input shaft 2 VIRTUS_MQB_INPUT_SHAFT_2

  • Service 22DID 380D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2018 to 2026.

Launch control counter, clutch 1 VIRTUS_LAUNCH_CTRL_CNT_CLU_1

  • Service 22DID 38C0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Load shift flaps, actual value VIRTUS_LOAD_SHIFT_FLAPS_ACT

  • Service 22DID 295C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Load shift flaps, specified value VIRTUS_LOAD_SHIFT_FLAPS_SPEC

  • Service 22DID 295D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Lower adapted coupling point clutch 1 from kiss point adaptation VIRTUS_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_KISS_POINT_ADAPT

  • Service 22DID 388D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2018 to 2026.

Lower adapted coupling point clutch 2 from kiss point adaptation VIRTUS_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_KISS_POINT_ADAPT

  • Service 22DID 388E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2018 to 2026.

Mileage of oxidation catalytic converter VIRTUS_MILEAGE_OXIDATION

  • Service 22DID 51A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2018 to 2026.

Neutral position gear selector 1-3 VIRTUS_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_1_3

  • Service 22DID 1140
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Neutral position gear selector 2-4 VIRTUS_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_2_4

  • Service 22DID 1141
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Neutral position gear selector 5 and neutral VIRTUS_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_5_N

  • Service 22DID 1142
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Neutral position gear selector 6 and reverse VIRTUS_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_6_R

  • Service 22DID 1143
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Nominal pressure clutch 2 VIRTUS_NOMINAL_P_CLU_2

  • Service 22DID 125D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 2018 to 2026.

Output shaft 1 VIRTUS_MQB_OUTPUT_SHAFT_1

  • Service 22DID 380E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2018 to 2026.

Output shaft 2 VIRTUS_MQB_OUTPUT_SHAFT_2

  • Service 22DID 380F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2018 to 2026.

Powertrain overall gear ratio VIRTUS_POWERTRAIN_OVERALL

  • Service 22DID 11DF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Number

In testing for 2018 to 2026.

Pressure_clutch_1 VIRTUS_P_CLU_1

  • Service 22DID 1260
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2018 to 2026.

Pressure_clutch_2 VIRTUS_P_CLU_2

  • Service 22DID 1261
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2018 to 2026.

Road resistance VIRTUS_PQ35_ROAD_RESISTANCE

  • Service 22DID 1017
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24.9100−31.6
Range
-31 to 31.894 %
Unit
%

In testing for 2018 to 2026.

Selected gear VIRTUS_PQ35_SELECTED_GEAR

  • Service 22DID 15AA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Selected gear VIRTUS_SELECTED_GEAR_7E1

  • Service 22DID 7050
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253 °C
Unit
°C

In testing for 2018 to 2026.

Shift process, selected gear VIRTUS_SHIFT_PROCCESS

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Shift process, target gear VIRTUS_SHIFT_PROCCESS_TGT

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Specified torque clutch 1 VIRTUS_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_1

  • Service 22DID 382E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
0 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Specified torque clutch 1 - data VIRTUS_SPEC_TQ_CLU_1_DATA

  • Service 22DID 2142
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2018 to 2026.

Specified torque clutch 2 VIRTUS_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_2

  • Service 22DID 3838
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
-1638 to 1638.35 N·m
Unit
N·m

In testing for 2018 to 2026.

Specified torque clutch 2 - data VIRTUS_SPEC_TQ_CLU_2_DATA

  • Service 22DID 2143
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2018 to 2026.

Stiffness point pressure clutch 1 VIRTUS_MQB_DL382_STIFFNESS_POINT_P_CLUTCH_1

  • Service 22DID 1419
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 bar
Unit
bar

In testing for 2018 to 2026.

Stiffness point pressure clutch 2 VIRTUS_MQB_DL382_STIFFNESS_POINT_P_CLUTCH_2

  • Service 22DID 141A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 bar
Unit
bar

In testing for 2018 to 2026.

Synchronous position side a gear selector 1-3 VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_1_3

  • Service 22DID 113C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Synchronous position side a gear selector 2-4 VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_2_4

  • Service 22DID 113D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Synchronous position side a gear selector 5 and neutral VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_5_N

  • Service 22DID 113E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Synchronous position side a gear selector 6 and reverse VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_6_R

  • Service 22DID 113F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Synchronous position side b gear selector 1-3 VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_1_3

  • Service 22DID 1148
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Synchronous position side b gear selector 2-4 VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_2_4

  • Service 22DID 1149
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Synchronous position side b gear selector 5 and neutral VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_5_N

  • Service 22DID 114A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Synchronous position side b gear selector 6 and reverse VIRTUS_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_6_R

  • Service 22DID 114B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2018 to 2026.

Time since shift VIRTUS_TIME_SINCE_SHIFT

  • Service 22DID 1033
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 2018 to 2026.

Torque converter amplification VIRTUS_TQ_CONV

  • Service 22DID 2130
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100
Range
0 to 2.55
Unit
Number

In testing for 2018 to 2026.

Torque converter lockup clutch status VIRTUS_MQB_TCM_TORQUE_CONVERTER_LOCKUP_CLUTCH_STATUS

  • Service 22DID 7078
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Torque loss adaptation, A/C compressor + gear engaged VIRTUS_TQ_LOSS_ADPT_AC_COMP

  • Service 22DID 1222
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque loss adaptation, gear engaged VIRTUS_TQ_LOSS_ADPT_GEAR

  • Service 22DID 1224
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Transmission coolant valve, open VIRTUS_TRANS_CLT_VLV_OPEN

  • Service 22DID 3D74
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Transmission fluid temperature 2 VIRTUS_ATF_T_2

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 38BF
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2026.

Transmission gear ratio VIRTUS_TRANS_GEAR_RAT

  • Service 22DID 0327
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val100
Range
-1.28 to 1.27
Unit
Number

In testing for 2018 to 2026.

Transmission part 1 pressure actual VIRTUS_MQB_TCM_TRANSMISSION_PART_1_P_ACTUAL

  • Service 22DID 3821
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2018 to 2026.

Transmission part 1 pressure commanded VIRTUS_MQB_TCM_TRANSMISSION_PART_1_P_CMD

  • Service 22DID 3820
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2018 to 2026.

Transmission part 1 valve current actual VIRTUS_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_ACTUAL

  • Service 22DID 3827
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2018 to 2026.

Transmission part 1 valve current commanded VIRTUS_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_CMD

  • Service 22DID 3826
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2018 to 2026.

Transmission part 2 pressure actual VIRTUS_MQB_TCM_TRANSMISSION_PART_2_P_ACTUAL

  • Service 22DID 3824
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2018 to 2026.

Transmission part 2 pressure commanded VIRTUS_MQB_TCM_TRANSMISSION_PART_2_P_CMD

  • Service 22DID 3823
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2018 to 2026.

Transmission part 2 valve current actual VIRTUS_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_ACTUAL

  • Service 22DID 382B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2018 to 2026.

Transmission part 2 valve current commanded VIRTUS_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_CMD

  • Service 22DID 382A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2018 to 2026.

Upper adapted coupling point clutch 1 from micro-slip adaptation VIRTUS_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_MICROSLIP_ADAPT

  • Service 22DID 388F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2018 to 2026.

Upper adapted coupling point clutch 2 from micro-slip adaptation VIRTUS_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_MICROSLIP_ADAPT

  • Service 22DID 3890
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2018 to 2026.

Working hours VIRTUS_PQ35_WORKING_HOURS

  • Service 22DID 1110
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×2360000
Range
0 to 23860.929
Unit
Raw value

In testing for 2018 to 2026.

Trips

Analysis, clutch 1 temperature time in range 1 VIRTUS_ANALYSIS_CLU_1_T_1

  • Service 22DID 1066
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Analysis, clutch 1 temperature time in range 2 VIRTUS_ANALYSIS_CLU_1_T_2

  • Service 22DID 1067
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Analysis, clutch 1 temperature time in range 3 VIRTUS_ANALYSIS_CLU_1_T_3

  • Service 22DID 1068
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Analysis, clutch 2 temperature time in range 0 VIRTUS_ANALYSIS_CLU_2_T_0

  • Service 22DID 107A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Analysis, clutch 2 temperature time in range 1 VIRTUS_ANALYSIS_CLU_2_T_1

  • Service 22DID 107B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Analysis, clutch 2 temperature time in range 2 VIRTUS_ANALYSIS_CLU_2_T_2

  • Service 22DID 107C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Analysis, clutch 2 temperature time in range 3 VIRTUS_ANALYSIS_CLU_2_T_3

  • Service 22DID 107D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Clutch 1 adaptation kiss point part 1 odometer reading VIRTUS_PQ35_CLUTCH_1_ADAPT_KISS_POINT_PART_1_ODO_READING

  • Service 22DID 10CA
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2018 to 2026.

Clutch 1 temperature time in range 0 VIRTUS_CLU_1_T_TIME_RANGE_0

  • Service 22DID 1065
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Clutch 2 adaptation kiss point part 1 odometer reading VIRTUS_PQ35_CLUTCH_2_ADAPT_KISS_POINT_PART_1_ODO_READING

  • Service 22DID 10EB
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2018 to 2026.

Counter steer support, odometer, last activated VIRTUS_CNT_STEER_SUPPORT_ODO_RDG_OF_LAST_ACTConfirmed

  • Service 22DID 18B6
  • Module713 → 77D
  • Every900 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 1 km
Unit
km

0x000000 = 0 → 0 km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Distance since last regeneration VIRTUS_DIST_SINCE_REGEN

  • Service 22DID 208D
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2018 to 2026.

Drive cycles counter VIRTUS_MQB_TCM_DRIVE_CYCLES_COUNTER

  • Service 22DID 388B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Driving time ecological VIRTUS_MQB_TCM_DRIVING_TIME_ECOLOGICAL

  • Service 22DID 3888
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Driving time manual VIRTUS_MQB_TCM_DRIVING_TIME_MANUAL

  • Service 22DID 388A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Driving time sporty VIRTUS_MQB_TCM_DRIVING_TIME_SPORTY

  • Service 22DID 3889
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Ignition cycles VIRTUS_MQB_TCM_IGNITION_CYCLES

  • Service 22DID 388C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Mixture variation in adapted part load range 1 VIRTUS_MIXTURE_VARIATION_1

  • Service 22DID 39BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Odometer VIRTUS_ODO_7E0Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 10E0
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4000000000 km
Unit
km

0x000073F0 = 29680 → 29,680 km

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Odometer VIRTUS_ODO_7E0_7E0

Pelican can show this parameter as the odometer.

  • Service 22DID 108C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2018 to 2026.

Odometer VIRTUS_ODO_7E1

Pelican can show this parameter as the odometer.

  • Service 22DID 103D
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2018 to 2026.

Odometer VIRTUS_ODO_V1Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 3841
  • Module7E1
  • Every30 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729 km
Unit
km

0x60870400 = 1619461120 → 161946112010 = 161,946,112 km

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Odometer #2 VIRTUS_MQB_TCM_ODO_2Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 3887
  • Module7E1
  • Every30 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

0x00000000 = 0 → 010 = 0 km

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Odometer #3 VIRTUS_PQ35_ODO_3Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 101A
  • Module7E1
  • Every30 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 16777215 km
Unit
km

0x00559F = 21919 → 21,919 km

Confirmed for 2022. In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2024.

Odometer at oxidation catalytic converter replacement VIRTUS_ODO_OXYDATION

  • Service 22DID 4F3F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2018 to 2026.

Odometer reading at fourth-to-last warning VIRTUS_TPMS_ODO_RDG_AT_FOURTH_TO_LAST_WARNConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 232 to 263 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x0000A822 = 43042 → 43,042 km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Odometer reading at last adaptation VIRTUS_TPMS_ODO_RDG_AT_LAST_ADAPTConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Odometer reading at last warning VIRTUS_TPMS_ODO_RDG_AT_LAST_WARNConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 136 to 167 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Odometer reading at next-to-last warning VIRTUS_TPMS_ODO_RDG_AT_NEXT_TO_LAST_WARNConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 168 to 199 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Odometer reading at third-to-last warning VIRTUS_TPMS_ODO_RDG_AT_THIRD_TO_LAST_WARNConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 200 to 231 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Odometer reading four adaptations ago VIRTUS_TPMS_ODO_RDG_FOUR_ADAPTATIONS_AGOConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 104 to 135 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Odometer reading three adaptations ago VIRTUS_TPMS_ODO_RDG_THREE_ADAPTATIONS_AGOConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Virtus.

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

0x0000133F = 4927 → 4,927 km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Odometer reading two adaptations ago VIRTUS_TPMS_ODO_RDG_TWO_ADAPTATIONS_AGOConfirmed

  • Service 22DID 1821
  • Module713 → 77D
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 200000 km
Unit
km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Odometer with ECU installed, variant 2 VIRTUS_ODO_ECU_INSTALLED_2

  • Service 22DID 295B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 m
Unit
m

In testing for 2018 to 2026.

Odometer, alternate VIRTUS_PQ35_ODO_2

Pelican can show this parameter as the odometer.

  • Service 22DID 16A9
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2018 to 2026.

Odometer, alternative VIRTUS_ODO_2

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2018 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Odometer, high resolution VIRTUS_ODO_HDConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 1160
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2018 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Volkswagen Virtus.

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

0x01C2180B = 29497355 → 294973551000 = 29,497.355 km

Confirmed for 2022, 2024. In testing for 2018 to 2021, 2023, 2025 to 2026.

Operating time, temperature range 1 VIRTUS_OP_TIME_T_RANGE_1

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860.74294967295
Range
0 to 23860.7 h
Unit
h

In testing for 2018 to 2026.

Operating time, temperature range 2 VIRTUS_OP_TIME_T_RANGE_2

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860.74294967295
Range
0 to 23860.7 h
Unit
h

In testing for 2018 to 2026.

Operating time, temperature range 3 VIRTUS_OP_TIME_T_RANGE_3

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860.74294967295
Range
0 to 23860.7 h
Unit
h

In testing for 2018 to 2026.

Operating time, temperature range 4 VIRTUS_OP_TIME_T_RANGE_4

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860.74294967295
Range
0 to 23860.7 h
Unit
h

In testing for 2018 to 2026.

Operating time, temperature range 5 VIRTUS_OP_TIME_T_RANGE_5

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860.74294967295
Range
0 to 23860.7 h
Unit
h

In testing for 2018 to 2026.

Operating time, temperature range 6 VIRTUS_OP_TIME_T_RANGE_6

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860.74294967295
Range
0 to 23860.7 h
Unit
h

In testing for 2018 to 2026.

Remaining distance until reducing agent deficiency VIRTUS_REMAINING_DIST_UNTIL

  • Service 22DID 29B1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val20
Range
0 to 214748364 km
Unit
km

In testing for 2018 to 2026.

Torque converter time in temperature range 1 VIRTUS_TQ_CONV_TIME_T_RANGE_1

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2018 to 2026.

Torque converter time in temperature range 2 VIRTUS_TQ_CONV_TIME_T_RANGE_2

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 47 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2018 to 2026.

Torque converter time in temperature range 3 VIRTUS_TQ_CONV_TIME_T_RANGE_3

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2018 to 2026.

Torque converter time in temperature range 4 VIRTUS_TQ_CONV_TIME_T_RANGE_4

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2018 to 2026.

Torque converter time in temperature range 5 VIRTUS_TQ_CONV_TIME_T_RANGE_5

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 119 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2018 to 2026.

Torque converter time in temperature range 6 VIRTUS_TQ_CONV_TIME_T_RANGE_6

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 143 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2018 to 2026.

Torque converter time in temperature range 7 VIRTUS_TQ_CONV_TIME_T_RANGE_7

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 144 to 167 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2018 to 2026.

Torque converter time in temperature range 8 VIRTUS_TQ_CONV_TIME_T_RANGE_8

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 168 to 191 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2018 to 2026.

VIRTUS_PQ35_TIME_LAST

Time since last regeneration VIRTUS_PQ35_TIME_LAST_REGEN

  • Service 22DID 115E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10066666667
Range
0 to 0.426 min
Unit
min

In testing for 2018 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.