Volkswagen Taigo

Parameters

The Volkswagen Taigo has 1,194 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Control module voltage TAIGO_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x3038 = 12344 → 123441000 = 12.344 V

Confirmed for 2022. In testing for 2021, 2023 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Accelerator pedal, sensor 1 voltage TAIGO_ACCEL_PEDAL_SENS_1_V

  • Service 22DID 102A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2021 to 2026.

Accelerator pedal, sensor 2 voltage TAIGO_ACCEL_PEDAL_SENS_2_V

  • Service 22DID 102B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2021 to 2026.

Aux. hydraulic pump voltage TAIGO_AUX_HYDRAULIC_PMP_V

  • Service 22DID 51A7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2021 to 2026.

Battery voltage TAIGO_BAT_V

  • Service 22DID 105A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2021 to 2026.

Battery voltage variant TAIGO_PQ35_BAT_V_2

  • Service 22DID 105E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2021 to 2026.

Boost pressure TAIGO_PQ35_CHG_P

  • Service 22DID 1057
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2021 to 2026.

Bypass valve high pressure turbine inlet, raw voltage TAIGO_BYPASS_VLV_HIGH_P_V

  • Service 22DID 3D01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2021 to 2026.

Calculated nitrogen oxide concentration behind turbocharger TAIGO_MQB_NOX_CONC_BEHIND_TURBO

  • Service 22DID 1526
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2021 to 2026.

Charge adjuster output stage TAIGO_HIGH_P_TURBOCHARGER

  • Service 22DID 1181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2021 to 2026.

Charge air cooler inlet, pressure sensor 1 bank 1 raw value TAIGO_CHG_AIR_COOLER_INLET_P_1_1

  • Service 22DID 445A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Raw value

In testing for 2021 to 2026.

Charge air pressure actuator position digit.value TAIGO_CHG_AIR_P_ACTUATOR_7E0

  • Service 22DID 1B11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Charge air pressure, actual value TAIGO_AIR_P_CAC_DS

  • Service 22DID 1056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2021 to 2026.

Charge air pressure, actual value TAIGO_CHG_AIR_P_ACT

  • Service 22DID 1B0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119
Unit
Raw value

In testing for 2021 to 2026.

Charge air pressure, specified value TAIGO_CHG_AIR_P_SPEC

  • Service 22DID FE47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2021 to 2026.

Charge air pressure: actual TAIGO_PQ35_CHARGE_AIR_P_ACTUAL

  • Service 22DID 202A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08
Range
0 to 5242.8
Unit
Raw value

In testing for 2021 to 2026.

Charge air pressure: specified TAIGO_PQ35_CHARGE_AIR_P_SPECIFIED

  • Service 22DID 2029
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.08
Range
0 to 5242.8
Unit
Raw value

In testing for 2021 to 2026.

Charge air temp at the turbocharger outlet, calculated TAIGO_MQB_CHARGE_AIR_T_TUBROCHARGER_OUTLET_CALCULATED

  • Service 22DID 1798
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000−273.1
Range
-273.1 to 3003.6 °C
Unit
°C

In testing for 2021 to 2026.

Charge limit overcharge protection TAIGO_PQ35_CHG_LIM_OVER

  • Service 22DID 1356
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2021 to 2026.

Charge pressure actuator, acknowledgment TAIGO_CHG_P_ACTUATOR

  • Service 22DID 2065
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2021 to 2026.

Charge pressure actuator, actual position TAIGO_CHG_P_ACTUATOR_ACT

  • Service 22DID 39A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Charge pressure actuator, adaptation for lower stop TAIGO_CHG_P_ACTUATOR_ADPT

  • Service 22DID 39A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2021 to 2026.

Charge pressure actuator, adaptation for upper stop TAIGO_CHG_P_ACTUATOR_ADPT_HI

  • Service 22DID 39A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2021 to 2026.

Charge pressure actuator, maximum sensor voltage TAIGO_CHG_P_ACTUATOR_MAX_V

  • Service 22DID 3D77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 mV
Unit
mV

In testing for 2021 to 2026.

Charge pressure actuator, specified position TAIGO_CHG_P_ACTUATOR_SPEC

  • Service 22DID 39A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2021 to 2026.

Charge pressure actuator, specified value TAIGO_CHG_P_ACTUATOR_SPEC_7E0

  • Service 22DID 39A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Charge pressure before throttle valve, calculated actual value TAIGO_CHG_P_BEFORE_ACT

  • Service 22DID 432B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191
Unit
Raw value

In testing for 2021 to 2026.

Charge pressure control specified value TAIGO_CHG_P_CTRL_SPEC

  • Service 22DID 1108
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Charge pressure control valve activation pulse duty factor TAIGO_CHG_P_CTRL_VLV

  • Service 22DID 3EA9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2021 to 2026.

Charge pressure control valve position, actual value TAIGO_CHG_P_CTRL_VLV_POS_ACT

  • Service 22DID 3EA7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Charge pressure control valve position, target value TAIGO_CHG_P_CTRL_VLV_POS_TGT

  • Service 22DID 3EA6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Charge pressure control valve sensor voltage TAIGO_CHG_P_CTRL_VLV_SENS_V

  • Service 22DID 3EA8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2021 to 2026.

Charge pressure control valve voltage, position closed TAIGO_CHG_P_CTRL_VLV_V_POS

  • Service 22DID 3EAB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2021 to 2026.

Charge pressure control valve voltage, position opened TAIGO_CHG_P_CTRL_VLV_V_POS_OPENED

  • Service 22DID 3EAC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2021 to 2026.

Charge pressure control, adapt. higher than max. threshold TAIGO_CHG_P_CTRL_ADAPT_MAX

  • Service 22DID 293E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Charge pressure control, adapt. lower than min. threshold TAIGO_CHG_P_CTRL_ADAPT_LO_MIN

  • Service 22DID 293F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Charge pressure regulator, lower threshold adaptation TAIGO_CHG_P_REGULATOR_LO

  • Service 22DID 16EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2021 to 2026.

Charge pressure regulator, upper threshold adaptation TAIGO_CHG_P_REGULATOR_HI

  • Service 22DID 16ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2021 to 2026.

Charge pressure sensor, unconditioned voltage TAIGO_CHG_P_SENS_V

  • Service 22DID 29C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2021 to 2026.

Control module voltage TAIGO_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x3038 = 12344 → 123441000 = 12.344 V

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Cylinder charge specified value TAIGO_CYL_CHG_SPEC

  • Service 22DID 432F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2021 to 2026.

Cylinder charge, actual value TAIGO_CYL_CHG_ACT

  • Service 22DID 4367
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2021 to 2026.

ECall battery charge level TAIGO_ECALL_SOC

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

ECall battery status TAIGO_ECALL_STATUS

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueState
1CRITICAL
2NORMAL

In testing for 2021 to 2026.

Exhaust gas recirculation valve 1, B1, mass current: specified value TAIGO_MQB_EGR_VALVE_1_B1_MASS_I_SPEC

  • Service 22DID 1813
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2021 to 2026.

Exhaust gas recirculation valve 2, B1, mass current: specified value TAIGO_MQB_EGR_VALVE_2_B1_MASS_I_SPEC

  • Service 22DID 1814
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2021 to 2026.

High pressure exhaust gas recirculation actuator, actual unconditioned voltage TAIGO_HIGH_P_EGR_ACTUATOR_ACT_V

  • Service 22DID 11A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2021 to 2026.

Ignition angle current cylinder TAIGO_PQ35_IGN_ANG_CYL

  • Service 22DID 137A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−35.625
Range
-35.625 to 60 N·m
Unit
N·m

In testing for 2021 to 2026.

Knock sensor voltage, cylinder 1 TAIGO_KNOCK_SENS_V_CYL_1

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2021 to 2026.

Knock sensor voltage, cylinder 3 TAIGO_KNOCK_SENS_V_CYL_3_7E0

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2021 to 2026.

Knock sensor voltage:, cylinder 2 TAIGO_KNOCK_SENS_V_CYL_2

  • Service 22DID 13FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2021 to 2026.

Knock sensor voltage:, cylinder 3 TAIGO_KNOCK_SENS_V_CYL_3

  • Service 22DID 13FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2021 to 2026.

Knock sensor voltage:, cylinder 5 TAIGO_KNOCK_SENS_V_CYL_5

  • Service 22DID 13FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000076294
Range
0 to 4.99 V
Unit
V

In testing for 2021 to 2026.

Knock sensors average voltage bank 1,, variant 2 TAIGO_KNOCK_SENSORS_AVG_V_1_2

  • Service 22DID 4E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2021 to 2026.

Maximum charge current TAIGO_MAX_CHA_CUR_2

  • Service 22DID 1159
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

In testing for 2021, 2023 to 2026. Not supported for 2022.

Maximum discharge current TAIGO_MAX_DCHA_CUR_2Confirmed

  • Service 22DID 1158
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Temperature sensor for engine temperature management voltage TAIGO_T_SENS_ENG_T_V

  • Service 22DID 40E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2021 to 2026.

Turbocharger inlet pressure corrected value TAIGO_TURBOCHARGER_INLET_P

  • Service 22DID 11D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.078125
Range
0 to 5119
Unit
Raw value

In testing for 2021 to 2026.

Climate

A/C compressor torque, requested TAIGO_AC_COMP_T

  • Service 22DID 1002
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2021 to 2026.

Air conditioning compressor shutdown requirement TAIGO_MQB_TCM_A_C_COMPRESSOR_SHUTDOWN_REQUIREMENT

  • Service 22DID 381A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Air conditioning compressor torque TAIGO_PQ35_AC_COMP_TRQ

  • Service 22DID 104B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Ambient air temperature TAIGO_AAT_7E0_7E0

  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

Ambient temperature TAIGO_AAT_V2

  • Service 22DID 1004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-255 to 255 °C
Unit
°C

In testing for 2021, 2023 to 2026. Not supported for 2022.

Barometric pressure TAIGO_BARO

  • Service 22DID F433
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2021 to 2026.

Clocks

Time since engine start TAIGO_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x03FA = 1018 → 1,018 s

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Control

Accelerator pedal release detection threshold voltage TAIGO_APP_REDUCE_V

  • Service 22DID 1029
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2021 to 2026.

Brake booster pressure TAIGO_BRAKE_BOOSTER_P

  • Service 22DID 11CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×19531500000
Range
0 to 2559
Unit
Raw value

In testing for 2021 to 2026.

Brake booster raw pressure TAIGO_BRAKE_BOOSTER_RAW_P

  • Service 22DID 11D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2021 to 2026.

Brake booster, actual vacuum TAIGO_BRAKE_BOOSTER_ACT

  • Service 22DID 1490
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×390.6210000
Range
-1279 to 1279
Unit
Raw value

In testing for 2021 to 2026.

Brake pedal position TAIGO_BRAKE_PEDAL_POS

  • Service 22DID 105D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122.0710000
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Brake pressure TAIGO_BRAKE_P

  • Service 22DID 105C
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2021 to 2026.

Brake pressure TAIGO_BRAKE_P_7E0

  • Service 22DID 195D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2021 to 2026.

Brake pressure TAIGO_MQB_TCM_BRAKE_P

  • Service 22DID 3803
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Brake pressure TAIGO_PQ35_BRAKE_P

  • Service 22DID 18D0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2021 to 2026.

Brake system vacuum pump active TAIGO_BRAKE_SYSTEM_VACUUM

  • Service 22DID 395E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Downshift point adaptation voltage TAIGO_DOWNSHIFT_ADAPT_V

  • Service 22DID 1028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2021 to 2026.

Requested brake torque, auxiliary system TAIGO_REQ_BRAKE_TQ

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2021 to 2026.

Drivetrain

Driver torque requested #1 TAIGO_ENG_TRQ_REQ_1

  • Service 22DID 29D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2021 to 2026.

Driver torque requested #2 TAIGO_ENG_TRQ_REQ_2

  • Service 22DID 4380
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2021 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2022. Supported for 2023.

Distance traveled since diagnostic trouble codes cleared TAIGO_CLR_DISTConfirmed

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x48DF = 18655 → 18,655 km

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2022. Supported for 2023.

Distance traveled while mil was activated TAIGO_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2022. Supported for 2023.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2022. Supported for 2023.

Number of warm-ups since diagnostic trouble codes cleared TAIGO_WARM_UPSConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFF = 255 → 255

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022. Supported for 2023.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2022. Supported for 2023.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2022. Supported for 2023.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2022. Supported for 2023.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

ECU

Misfires, cylinder 2 TAIGO_MISFIRES__CYL__2Confirmed

  • Service 22DID 1152
  • Module7E0
  • Every1 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Misfires, cylinder 4 TAIGO_MISFIRES__CYL__4Confirmed

  • Service 22DID 1151
  • Module7E0
  • Every1 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Torque converter slip TAIGO_TORQUE_CONVERTER_SLIP

  • Service 22DID 2131
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2021 to 2026.

Engine

Absolute evap system vapor pressure EVAP_VPASAE J1979Confirmed

Normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Service 01PID 53
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327.675 kPa
Unit
kPa

Confirmed for 2022.

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2022. Supported for 2023.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2022.

Actual turbo boost TAIGO_ACT_TURBO_BOOST

  • Service 22DID 11F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2 bar
Unit
bar

In testing for 2021 to 2026.

Adaptation of loss torque TAIGO_ADPT_LOSS_TQ

  • Service 22DID 2929
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2021 to 2026.

Adaptation of throttle valve TAIGO_ADPT_THROTTLE_VLV

  • Service 22DID 292B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Adaptation val.cylinder1 fast diagnosis TAIGO_ADPT_VAL_CYL1_FAST

  • Service 22DID 3F45
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2021 to 2026.

Adaptation val.cylinder1 slow diagnosis TAIGO_ADPT_VAL_CYL1_SLOW

  • Service 22DID 3F41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2021 to 2026.

Adaptation val.cylinder2 fast diagnosis TAIGO_ADPT_VAL_CYL2_FAST

  • Service 22DID 3F48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2021 to 2026.

Adaptation val.cylinder2 slow diagnosis TAIGO_ADPT_VAL_CYL2_SLOW

  • Service 22DID 3F44
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2021 to 2026.

Adaptation val.cylinder3 fast diagnosis TAIGO_ADPT_VAL_CYL3_FAST

  • Service 22DID 3F46
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2021 to 2026.

Adaptation val.cylinder3 slow diagnosis TAIGO_ADPT_VAL_CYL3_SLOW

  • Service 22DID 3F42
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2021 to 2026.

Adaptation val.cylinder4 fast diagnosis TAIGO_ADPT_VAL_CYL4_FAST

  • Service 22DID 3F47
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2021 to 2026.

Adaptation val.cylinder4 slow diagnosis TAIGO_ADPT_VAL_CYL4_SLOW

  • Service 22DID 3F43
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2021 to 2026.

Adaptive mode TAIGO_ADAPTIVE_MODE

  • Service 22DID 1011
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Air conditioning compressor pressure TAIGO_AC_COMP_P

  • Service 22DID 1017
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070
Unit
Raw value

In testing for 2021 to 2026.

Air conditioning compressor pressure, linear raw value TAIGO_AC_COMP_P_LINEAR_RAW

  • Service 22DID 15C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070
Unit
Raw value

In testing for 2021 to 2026.

Air conditioning compressor refrigerant pressure TAIGO_AC_COMP_REFRIGERANT_P

  • Service 22DID 1048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2021 to 2026.

Air conditioning compressor torque TAIGO_AC_COMP_TQ

  • Service 22DID 101A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Air conditioning compressor torque TAIGO_AC_COMP_TQ_7E0

  • Service 22DID 2017
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 N·m
Unit
N·m

In testing for 2021 to 2026.

Air conditioning compressor torque TAIGO_AC_COMP_TQ_REQ

  • Service 22DID 1023
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2021 to 2026.

Air conditioning refrigerant pressure TAIGO_AC_REFRIGERANT_P

  • Service 22DID 412A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2021 to 2026.

Air filling TAIGO_AIR_FILLING

  • Service 22DID 121C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×11719500000
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Air leakage TAIGO_AIR_LEAKAGE

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2021 to 2026.

Air mass meter 1 TAIGO_MQB_AIR_MASS_1

  • Service 22DID 1024
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2021 to 2026.

Air mass, actual value, mg/stroke TAIGO_AIR_MASS_ACT_MG

  • Service 22DID 29D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2021 to 2026.

Alternator load TAIGO_ALTERNATOR_LOAD

  • Service 22DID 101C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2021 to 2026.

Ambient air pressure TAIGO_AMBIENT_AIR_P

  • Service 22DID 1509
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14
Unit
Raw value

In testing for 2021 to 2026.

Ambient air temperature, v1 TAIGO_AAT_V1

  • Service 22DID 14F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.18−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2021 to 2026.

Ambient temperature TAIGO_AAT_7E0

  • Service 22DID 1000
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2021 to 2026.

Ambient temperature TAIGO_AAT_7E0_2

  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2021 to 2026.

Analysis, clutch 1, maximum temperature TAIGO_ANALYSIS_CLU_1_MAX_T

  • Service 22DID 1064
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2021 to 2026.

Analysis, clutch 2, maximum temperature TAIGO_ANALYSIS_CLU_2_MAX_T

  • Service 22DID 1079
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2021 to 2026.

Automatic transmission fluid temperature, lifetime max TAIGO_ATF_MAX

  • Service 22DID 704F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2021 to 2026.

Aux. hydraulic pump internal temperature TAIGO_AUX_HYDRAULIC_PMP_T

  • Service 22DID 51A6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

Aux. hydraulic pump, current TAIGO_AUX_HYDRAULIC_PMP

  • Service 22DID 4E76
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 A
Unit
A

In testing for 2021 to 2026.

Average ignition timing angle delay adjustment TAIGO_AVG_IGN_TIM_ANG

  • Service 22DID 2949
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2021 to 2026.

Avg. injection time TAIGO_AVG_INJ_TIME

  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×410000
Range
0 to 1717986 ms
Unit
ms

In testing for 2021 to 2026.

Avg. injection time, variant 2 TAIGO_AVG_INJ_TIME_VAR_2

  • Service 22DID 2003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25 ms
Unit
ms

In testing for 2021 to 2026.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2022. Supported for 2023.

Basic correction factor:, cylinder 1, filtered TAIGO_BASIC_CORR_FACTOR_1

  • Service 22DID 171A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×7.99965535
Range
0 to 7.999
Unit
Number

In testing for 2021 to 2026.

Basic correction factor:, cylinder 2, filtered TAIGO_BASIC_CORR_FACTOR_2

  • Service 22DID 171D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×7.99965535
Range
0 to 7.999
Unit
Number

In testing for 2021 to 2026.

Basic correction factor:, cylinder 3, filtered TAIGO_BASIC_CORR_FACTOR_3

  • Service 22DID 171B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×7.99965535
Range
0 to 7.999
Unit
Number

In testing for 2021 to 2026.

Basic correction factor:, cylinder 4, filtered TAIGO_BASIC_CORR_FACTOR_4

  • Service 22DID 171C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×7.99965535
Range
0 to 7.999
Unit
Number

In testing for 2021 to 2026.

Boost press before throttle: calculated actual value TAIGO_PQ35_BOOST_P_BEFORE_THROTTLE_CALCULATED_ACT

  • Service 22DID 181A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2500
Range
-81920000 to 81917500
Unit
Raw value

In testing for 2021 to 2026.

Boost pressure actuator, commanded duty TAIGO_BOOST_P_ACTUATOR_CMD

  • Service 22DID 16EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.0122068184
Range
-399 to 100 %
Unit
%

In testing for 2021 to 2026.

Boost pressure sensor A BP_A_ACTSAE J1979Confirmed

Actual turbocharger/supercharger A boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2022.

Boost pressure sensor B BP_B_ACTSAE J1979Confirmed

Actual turbocharger/supercharger B boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2022.

Boost pressure, actual TAIGO_BOOST_P_ACT_7E0

  • Service 22DID 111E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×225
Range
0 to 5242
Unit
Raw value

In testing for 2021 to 2026.

Boost pressure, target TAIGO_BOOST_P_TGT

  • Service 22DID 1118
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550
Unit
Raw value

In testing for 2021 to 2026.

Boost regulation duty, commanded value TAIGO_BOOST_REGULATION_CMD

  • Service 22DID 1219
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234384354
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Boost regulator feedback TAIGO_BOOST_REGULATOR_FEEDBACK

  • Service 22DID 11CC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Bypass valve high pressure turbine inlet, activation TAIGO_BYPASS_VLV_HIGH_P_TURBINE_INLET

  • Service 22DID 39FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2021 to 2026.

Bypass valve high pressure turbine inlet, actual value TAIGO_BYPASS_VLV_HIGH_P_ACT

  • Service 22DID 39FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1008192
Range
-400 to 100 %
Unit
%

In testing for 2021 to 2026.

Bypass valve high pressure turbine inlet, offset closed TAIGO_BYPASS_VLV_HIGH_P

  • Service 22DID 39FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399 to 100 %
Unit
%

In testing for 2021 to 2026.

Bypass valve high pressure turbine inlet, offset open TAIGO_BYPASS_VLV_HIGH_P_TURBINE

  • Service 22DID 39FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399 to 100 %
Unit
%

In testing for 2021 to 2026.

Bypass valve high pressure turbine inlet, target value TAIGO_BYPASS_VLV_HIGH_P_TGT

  • Service 22DID 39FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1008192
Range
-400 to 100 %
Unit
%

In testing for 2021 to 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2022. Supported for 2023.

Calculated oil temperature TAIGO_PQ35_CALCULATED_OIL_T

  • Service 22DID 20A1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

Camshaft adaptation exhaust bank 1, phase position TAIGO_CAM_ADPT_EXH_BANK_1_PHASE

  • Service 22DID 2023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2021 to 2026.

Camshaft adaptation intake bank 1, activation TAIGO_CAM_ADPT_INT_BANK_1_ACTIVATION

  • Service 22DID 2930
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Camshaft adaptation intake bank 1, actual value TAIGO_CAM_ADPT_INT_BANK_1_ACT

  • Service 22DID 201E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2021 to 2026.

Camshaft adaptation intake bank 1, phase position TAIGO_CAM_ADPT_INT_BANK_1_PHASE

  • Service 22DID 2021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2021 to 2026.

Camshaft adaptation intake bank 1, specified value TAIGO_CAM_ADPT_INT_BANK_1_SPEC

  • Service 22DID 201D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2021 to 2026.

Camshaft adaptation intake, phase position TAIGO_CAM_ADPT_INT_PHASE

  • Service 22DID 1093
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×359991638350
Range
-720 to 719 °
Unit
°

In testing for 2021 to 2026.

Camshaft adaptation, exhaust bank 1, phase position TAIGO_CAM_ADPT_EXH_BANK_1

  • Service 22DID 1128
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×219.7310000
Range
-720 to 719 °
Unit
°

In testing for 2021 to 2026.

Camshaft adaptation, intake bank 1, phase position TAIGO_CAM_ADPT_INT_BANK_1

  • Service 22DID 1125
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×219.7310000
Range
-720 to 719 °
Unit
°

In testing for 2021 to 2026.

Camshaft adaptation, intake deviation TAIGO_CAM_ADPT_INT_DEV

  • Service 22DID 4FF5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2021 to 2026.

Camshaft adjustment intake test bank 1 TAIGO_CAM_ADJ_INT_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

Camshaft adjustment outlet test bank 1 TAIGO_CAM_ADJ_OUTLET_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

Camshaft adjustment, exhaust bank 1, actual value TAIGO_CAM_ADJ_EXH_BANK_1_ACT

  • Service 22DID 136C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2021 to 2026.

Camshaft adjustment, exhaust bank 1, specified value TAIGO_CAM_ADJ_EXH_BANK_1_SPEC

  • Service 22DID 1371
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2021 to 2026.

Camshaft adjustment, exhaust bank 2, actual value TAIGO_CAM_ADJ_EXH_BANK_2_ACT

  • Service 22DID 136D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °
Unit
°

In testing for 2021 to 2026.

Camshaft adjustment, exhaust bank 2, specified value TAIGO_CAM_ADJ_EXH_BANK_2_SPEC

  • Service 22DID 1372
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262 to 262 °
Unit
°

In testing for 2021 to 2026.

Camshaft adjustment, exhaust, activation TAIGO_CAM_ADJ_EXH

  • Service 22DID 127B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Camshaft adjustment, exhaust, specified value TAIGO_CAM_ADJ_EXH_SPEC

  • Service 22DID 2019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2021 to 2026.

Camshaft adjustment, intake bank 1, actual value TAIGO_CAM_ADJ_INT_BANK_1_ACT

  • Service 22DID 136E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78.12510000
Range
-256 to 255 °
Unit
°

In testing for 2021 to 2026.

Camshaft adjustment, intake bank 1, specified value TAIGO_CAM_ADJ_INT_BANK_1_SPEC

  • Service 22DID 1373
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2021 to 2026.

Camshaft end position TAIGO_PQ35_CAMS_END

  • Service 22DID 1341
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 °
Unit
°

In testing for 2021 to 2026.

Camshaft position, deviation from the base position TAIGO_CAM_POS_DEV_BASE_POS

  • Service 22DID 1385
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720 to 719 °
Unit
°

In testing for 2021 to 2026.

Camshaft start position TAIGO_PQ35_CAMS_START

  • Service 22DID 1007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 °
Unit
°

In testing for 2021 to 2026.

Cat. converter oxygen storage capacity measured TAIGO_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED_7E0

  • Service 22DID 1507
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5
Unit
Raw value

In testing for 2021 to 2026.

Cat. temperature, bank 1 TAIGO_CAT_T_BANK_1

  • Service 22DID 1298
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 2021 to 2026.

Cat. temperature, bank 2 TAIGO_CAT_T_BANK_2

  • Service 22DID 1299
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 2021 to 2026.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2022. Supported for 2023.

Catalyst temperature, calculated TAIGO_CAT_T_CALC

  • Service 22DID 1515
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5−50
Range
-50 to 1225 °C
Unit
°C

In testing for 2021 to 2026.

Centrifugal oil temperature TAIGO_PQ35_CENTRIFUGAL_OIL_T

  • Service 22DID 38B2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2021 to 2026.

Chain elongation inlet, mileage at last adaptation TAIGO_CHAIN_ELONGATION_INLET

  • Service 22DID 516C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2021 to 2026.

Chain elongation outlet, mileage at last adaptation TAIGO_CHAIN_ELONGATION

  • Service 22DID 5149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2021 to 2026.

Chain elongation, no of valid initial values, exhaust bank 1 TAIGO_CHAIN_ELONGATION_NO_VALID_1

  • Service 22DID 4189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Chain elongation, no of valid initial values, intake bank 1 TAIGO_CHAIN_ELONGATION_NO_1

  • Service 22DID 4187
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Clutch #1 maximum temperature TAIGO_PQ35_CLUTCH_1_MAXIMUM_T

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2021 to 2026.

Clutch #2 maximum temperature TAIGO_PQ35_CLUTCH_2_MAXIMUM_T

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2021 to 2026.

Clutch 0 temperature calculated TAIGO_MQB_DL382_CLUTCH_0_T_CALCULATED

  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2021 to 2026.

Clutch 1 temperature TAIGO_PQ35_CLUTCH_1_T

  • Service 22DID 102B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2021 to 2026.

Clutch 1 temperature protection overheat protection 1 quantity TAIGO_MQB_TCM_CLUTCH_1_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY

  • Service 22DID 3881
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Clutch 1 temperature protection warning 1 quantity TAIGO_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_1_QTY

  • Service 22DID 387F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Clutch 1 temperature protection warning 2 quantity TAIGO_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_2_QTY

  • Service 22DID 3880
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Clutch 2 temperature TAIGO_PQ35_CLUTCH_2_T

  • Service 22DID 102C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2021 to 2026.

Clutch 2 temperature protection overheat protection 1 quantity TAIGO_MQB_TCM_CLUTCH_2_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY

  • Service 22DID 3885
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Clutch 2 temperature protection warning 1 quantity TAIGO_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_1_QTY

  • Service 22DID 3883
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Clutch 2 temperature protection warning 2 quantity TAIGO_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_2_QTY

  • Service 22DID 3884
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Clutch center central plate temperature TAIGO_CLU_CENTER_CENTRAL_T

  • Service 22DID 102A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2021 to 2026.

Clutch temperature calculated TAIGO_MQB_DL382_CLUTCH_T_CALCULATED

  • Service 22DID 18E3
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2021 to 2026.

Commanded boost pressure A BP_A_CMDSAE J1979Confirmed

Turbocharger/supercharger A commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2022.

Commanded boost pressure B BP_B_CMDSAE J1979Confirmed

Turbocharger/supercharger B commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2022.

Commanded crankshaft torque TAIGO_CMD_CRANK_TQ

  • Service 22DID 11E0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2022. Supported for 2023.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2022. Supported for 2023.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2022.

Compression test cylinder 1 TAIGO_PQ35_COMPRESSION_TEST_CYL_1

  • Service 22DID 1129
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2021 to 2026.

Compression test cylinder 2 TAIGO_PQ35_COMP_TEST_CYL_2

  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2021 to 2026.

Compression test cylinder 3 TAIGO_PQ35_COMP_TEST_CYL_3

  • Service 22DID 112B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2021 to 2026.

Compression test, cylinder 1 TAIGO_COMPRESSION_TEST_CYL_1

  • Service 22DID 299B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2021 to 2026.

Compression test, cylinder 2 TAIGO_COMPRESSION_TEST_CYL_2

  • Service 22DID 299C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2021 to 2026.

Compression test, cylinder 3 TAIGO_COMPRESSION_TEST_CYL_3

  • Service 22DID 299D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2021 to 2026.

Compression test, cylinder 4 TAIGO_COMPRESSION_TEST_CYL_4

  • Service 22DID 299E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2021 to 2026.

Control module temperature TAIGO_CTRL_MODULE_T

  • Service 22DID 0301
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

Converter loss torque TAIGO_MQB_TCM_CONVERTER_LOSS_TORQUE

  • Service 22DID 1010
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Coolant at engine start TAIGO_CLT_ENG_START

  • Service 22DID 1291
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Coolant circulation pump, activation TAIGO_CLT_CIRCULATION_PMP_ACTIVATION

  • Service 22DID 276D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Coolant circulation pump, control TAIGO_CLT_CIRCULATION_PMP

  • Service 22DID 167E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Coolant fan 1 activation, $1117 TAIGO_CLT_FAN_1_ACTIVATION_1117

  • Service 22DID 1117
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2021 to 2026.

Coolant fan 1 duty cycle TAIGO_PQ35_COOL_FAN_1_DUTY

  • Service 22DID 1116
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Coolant fan 1, activation TAIGO_CLT_FAN_1_ACTIVATION

  • Service 22DID 2055
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Coolant fan 1, commanded duty TAIGO_CLT_FAN_1_CMD_DUTY

  • Service 22DID 1130
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Coolant fan 2 duty cycle TAIGO_PQ35_COOL_FAN_2_DUTY

  • Service 22DID 1114
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Coolant fan 2, activation TAIGO_CLT_FAN_2_ACTIVATION

  • Service 22DID 2056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Coolant fan, requested by A/C TAIGO_CLT_FAN_REQ_AC

  • Service 22DID 1018
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2021 to 2026.

Coolant shut-off valve, closed TAIGO_CLT_SHUT_OFF_VLV

  • Service 22DID 2682
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2021 to 2026.

Coolant temperature at engine outlet, calculated TAIGO_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED_7E0

  • Service 22DID 4490
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature at engine outlet, calculated TAIGO_ECT_ENG_OUTLET_CALC

  • Service 22DID 1064
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature at engine start TAIGO_ECT_ENG_START

  • Service 22DID 2935
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature at radiator outlet TAIGO_COOLANT_T

  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature at radiator outlet TAIGO_ECT_RADIATOR_OUTLET

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature at radiator outlet 2 TAIGO_ECT_RAD_OUT_2

  • Service 22DID 109B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature at radiator outlet v.1 TAIGO_ECT_RADIATOR_OUTLET_V_1

  • Service 22DID 15CD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature at radiator outlet v.3 TAIGO_ECT_RADIATOR_OUTLET_V_3

  • Service 22DID 202B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature at radiator outlet, actual value TAIGO_ECT_RADIATOR_OUTLET_ACT_7E0

  • Service 22DID 102C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature at radiator outlet, specified value TAIGO_ECT_RADIATOR_OUTLET_SPEC

  • Service 22DID 202C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature difference between engine and radiator TAIGO_ECT_DIFF_ENG

  • Service 22DID 202E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature linear TAIGO_ECT_LINEAR

  • Service 22DID 1513
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29.29710000−48
Range
-48 to 143 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature modeled value TAIGO_ECT_MODELED

  • Service 22DID 13A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature, maximum value TAIGO_ECT_MAX

  • Service 22DID 1511
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2021 to 2026.

Coolant temperature, minimum value TAIGO_ECT_MIN

  • Service 22DID 1512
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2021 to 2026.

Correction factor of oil temperature for engine protection TAIGO_CORR_FACTOR_OIL_T

  • Service 22DID 3F4F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12207100000000
Range
0 to 7.99
Unit
Number

In testing for 2021 to 2026.

Correction values for main pressure adaptation TAIGO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT

  • Service 22DID 11A7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Crankshaft rotation angle when closing the quantity control valve TAIGO_CRANK_ROT_ANG

  • Service 22DID 10EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2021 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 0 TAIGO_CTR_MIS_DC_MMV_CYL_0

  • Service 22DID 148D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 1 TAIGO_CTR_MIS_DC_MMV_CYL_1

  • Service 22DID 148E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 2 TAIGO_CTR_MIS_DC_MMV_CYL_2

  • Service 22DID 148F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Current N215 pressure control valve 1 TAIGO_CURRENT_N215_P_CTRL_1

  • Service 22DID 1024
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2021 to 2026.

Current N216 pressure control valve 2 TAIGO_CURRENT_N216_P_CTRL_2

  • Service 22DID 1026
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2021 to 2026.

Current N217 pressure control valve 3 TAIGO_CURRENT_N217_P_CTRL_3

  • Service 22DID 1028
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2021 to 2026.

Current N218 pressure control valve 4 TAIGO_CURRENT_N218_P_CTRL_4

  • Service 22DID 1025
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2021 to 2026.

Current N233 pressure control valve 5 TAIGO_CURRENT_N233_P_CTRL_5

  • Service 22DID 1027
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2021 to 2026.

Current solenoid TAIGO_CURRENT_SOLENOID

  • Service 22DID 1037
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2021 to 2026.

Current type of driver counter TAIGO_CURRENT_TYPE_DRIVER

  • Service 22DID 1013
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Cylinder 1 internal torque TAIGO_CYL_1_INTERNAL_TQ

  • Service 22DID 5847
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Cylinder 2 internal torque TAIGO_CYL_2_INTERNAL_TQ

  • Service 22DID 5849
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Cylinder 3 internal torque TAIGO_CYL_3_INTERNAL_TQ

  • Service 22DID 584B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Cylinder 4 internal torque TAIGO_CYL_4_INTERNAL_TQ

  • Service 22DID 584D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Cylinder block temperature sensor TAIGO_CYL_BLOCK_T_SENS

  • Service 22DID 51D4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2021 to 2026.

Cylinder head temperature TAIGO_CYL_HEAD_T

  • Service 22DID 1065
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.18−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2021 to 2026.

Desired torque raw TAIGO_DES_TQ_RAW

  • Service 22DID 1061
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2021 to 2026.

Differential pressure TAIGO_PQ35_DIFF_P

  • Service 22DID 14F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2021 to 2026.

Direct injections counter TAIGO_DIRECT_INJECTIONS

  • Service 22DID 4267
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2021 to 2026.

Drive motor current TAIGO_MOTOR_I

  • Service 22DID 147D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 A
Unit
A

In testing for 2021 to 2026.

Drive motor torque TAIGO_MOTOR_TQ

  • Service 22DID 147F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val3
Range
-10922.666 to 10922.333 N·m
Unit
N·m

In testing for 2021 to 2026.

Driver demand torque TAIGO_MQB_TCM_DRIVER_DEMAND_TORQUE

  • Service 22DID 100B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Driving mode sensor, hall sensor a TAIGO_DRIVING_MODE_SENS

  • Service 22DID 210D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Driving position TAIGO_DRIVING_POS

  • Service 22DID 210E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Driving resistance index TAIGO_DRIVING_RES_INDEX

  • Service 22DID 2108
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2021 to 2026.

Dynamic average of ignition angle delay adjustment TAIGO_DYNAMIC_AVG_IGN_ANG

  • Service 22DID 294A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2021 to 2026.

Ea888b boost pressure control, adaptation value 0 TAIGO_EA888B_BOOST_P_CTRL_0

  • Service 22DID 11FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2021 to 2026.

Ea888b boost pressure control, adaptation value 1 TAIGO_EA888B_BOOST_P_CTRL_1

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2021 to 2026.

Ea888b boost pressure control, adaptation value 2 TAIGO_EA888B_BOOST_P_CTRL_2

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2021 to 2026.

Ea888b boost pressure control, adaptation value 3 TAIGO_EA888B_BOOST_P_CTRL_3

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2021 to 2026.

Ea888b boost pressure regulator, commanded TAIGO_EA888B_BOOST_P_CMD

  • Service 22DID 11A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Early ignition counter for toque reduction, cylinder 1 TAIGO_EARLY_IGN_CNT_TOQUE_1

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter for toque reduction, cylinder 2 TAIGO_EARLY_IGN_CNT_TOQUE_2

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter for toque reduction, cylinder 3 TAIGO_EARLY_IGN_CNT_TOQUE_3

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter for toque reduction, cylinder 4 TAIGO_EARLY_IGN_CNT_TOQUE_4

  • Service 22DID 4E4A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, cylinder 1 TAIGO_EARLY_IGN_CNT_CYL_1

  • Service 22DID 1722
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, cylinder 2 TAIGO_EARLY_IGN_CNT_CYL_2

  • Service 22DID 1725
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, cylinder 3 TAIGO_EARLY_IGN_CNT_CYL_3

  • Service 22DID 1723
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, cylinder 4 TAIGO_EARLY_IGN_CNT_CYL_4

  • Service 22DID 1724
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 1 TAIGO_EARLY_IGN_CNT_CYL_SUPPRESS_1

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 2 TAIGO_EARLY_IGN_CNT_CYL_SUPPRESS_2

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 3 TAIGO_EARLY_IGN_CNT_CYL_SUPPRESS_3

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, cylinder suppress early ignition, cylinder 4 TAIGO_EARLY_IGN_CNT_CYL_SUPPRESS_4

  • Service 22DID 4E49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 1 TAIGO_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_1

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 2 TAIGO_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_2

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 3 TAIGO_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_3

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, cylinder suppress glow ignition, cylinder 4 TAIGO_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_4

  • Service 22DID 4E4B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, total, cylinder 1 TAIGO_EARLY_IGN_CNT_TOT_1

  • Service 22DID 1715
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, total, cylinder 2 TAIGO_EARLY_IGN_CNT_TOT_2

  • Service 22DID 1718
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, total, cylinder 3 TAIGO_EARLY_IGN_CNT_TOT_3

  • Service 22DID 1716
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter, total, cylinder 4 TAIGO_EARLY_IGN_CNT_TOT_4

  • Service 22DID 1717
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Effective injection duration TAIGO_EFFECTIVE_INJ_DUR

  • Service 22DID 15E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

In testing for 2021 to 2026.

EGT after catalyst, model bank b TAIGO_EGT_AFTER_CAT_MODEL_B

  • Service 22DID 2AE3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.023438−273.15
Range
-273 to 1262 °C
Unit
°C

In testing for 2021 to 2026.

EGT after catalyst, modeled TAIGO_EGT_AFTER_CAT

  • Service 22DID 1272
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

EGT at lambda sensor 1, modeled TAIGO_EGT_LAMBDA_SENS_1

  • Service 22DID 139C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Elector motor 3 torque TAIGO_EM_TORQ_3Confirmed

  • Service 22DID 1155
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

0x0000 = 0 → 032 = 0 N·m

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Electric additional coolant pump control, high circle TAIGO_ELEC_ADDITIONAL_CLT

  • Service 22DID 1488
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2021 to 2026.

Engine air mass, specified value TAIGO_ENG_AIR_MASS_SPEC

  • Service 22DID 2037
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2021 to 2026.

Engine compartment temperature raw value TAIGO_ENG_COMPARTMENT_T

  • Service 22DID 46B1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549 to 3003 °C
Unit
°C

In testing for 2021 to 2026.

Engine control module temperature TAIGO_ENG_CTRL_MODULE_TConfirmed

  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 °C
Unit
°C

0x018B = 395 → 39510 = 39.5 °C

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Engine control unit temperature TAIGO_MQB_TCM_ECU_T

  • Service 22DID 028D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2021 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022. Supported for 2023.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022.

Engine drag torque TAIGO_ENG_DRAG_TQ

  • Service 22DID 209C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2022.

Engine module 10E0, raw TAIGO_ECM_10E0_RAWConfirmed

  • Service 22DID 10E0
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x1088 = 4232 → 4,232

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Engine module 11BD, raw TAIGO_ECM_11BD_RAWConfirmed

  • Service 22DID 11BD
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Engine module 11BE, raw TAIGO_ECM_11BE_RAWConfirmed

  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Engine oil level TAIGO_ENG_OIL_LEVEL_7E0

  • Service 22DID 1504
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mm
Unit
mm

In testing for 2021 to 2026.

Engine oil level TAIGO_PQ35_OIL_LVL

  • Service 22DID 11BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 mm
Unit
mm

In testing for 2021 to 2026.

Engine oil level current value TAIGO_ENG_OIL_LEVEL

  • Service 22DID 58D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2021 to 2026.

Engine oil pressure TAIGO_EOP

  • Service 22DID 1503
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val416
Range
0 to 157 psi
Unit
psi

In testing for 2021 to 2026.

Engine oil sump temperature TAIGO_ENG_OIL_SUMP_T

  • Service 22DID 15B7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.18−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2021 to 2026.

Engine oil temperature TAIGO_EOT_7E0_7E0

  • Service 22DID 1102
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

Engine oil temperature measured value TAIGO_EOT_MEAS

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2021 to 2026.

Engine oil temperature, calculated TAIGO_EOT_CALC

  • Service 22DID 201A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2021 to 2026.

Engine oil temperature, pulse sensor TAIGO_EOT_PULS

  • Service 22DID 179E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2021 to 2026.

Engine oil temperature, variant 3 TAIGO_EOT_VAR_3

  • Service 22DID 202F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Engine oil temperature, variant 4 TAIGO_EOT_VAR_4

  • Service 22DID 40D5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2021 to 2026.

Engine outlet coolant temperature calculated TAIGO_ENG_OUTLET_ECT_CALC

  • Service 22DID 1063
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Engine protection, torque limit TAIGO_ENG_PROTECTION_TQ

  • Service 22DID 2BC0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine radiator fan request TAIGO_ENG_RADIATOR_FAN_REQ

  • Service 22DID 100B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2022.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2022. Supported for 2023.

Engine start quantity TAIGO_PQ35_ENG_START_QTY

  • Service 22DID 1069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2021 to 2026.

Engine temperature control actuator TAIGO_ENG_T_CTRL_ACTUATOR

  • Service 22DID 3D73
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Engine temperature management actuator, after-run stop TAIGO_ENG_T_MANAGEMENT_ACTUATOR_AFTER

  • Service 22DID 441D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Engine temperature management actuator, duty cycle activation TAIGO_ENG_T_MANAGEMENT_ACTUATOR

  • Service 22DID 441A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2021 to 2026.

Engine temperature management actuator, raw value TAIGO_ENG_T_MANAGEMENT

  • Service 22DID 4419
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Engine temperature management actuator, specified value TAIGO_ENG_T_MANAGEMENT_SPEC

  • Service 22DID 3FE4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2021 to 2026.

Engine temperature management actuator, stop open TAIGO_ENG_T_MANAGEMENT_ACTUATOR_STOP

  • Service 22DID 441C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Engine torque TAIGO_ENG_TQ

  • Service 22DID 1010
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine torque TAIGO_ENG_TQ_7E0

  • Service 22DID 2002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine torque TAIGO_ENG_TQ_7E0_7E0

  • Service 22DID 437C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine torque TAIGO_ENG_TQ_7E1

  • Service 22DID 2002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine torque TAIGO_MQB_TCM_ENG_TORQUE

  • Service 22DID 7064
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine torque TAIGO_MQB_TCM_ENGINE_TORQUE

  • Service 22DID 100C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine torque TAIGO_PQ35_ENG_TORQUE

  • Service 22DID 155A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine torque TAIGO_PQ35_ENG_TRQ

  • Service 22DID 1047
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine torque limitation TAIGO_ENG_TQ_LIM

  • Service 22DID 108F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine torque limitation TAIGO_MQB_TCM_ENGINE_TORQUE_LIMITATION

  • Service 22DID 100E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine torque loss TAIGO_MQB_TCM_ENGINE_TORQUE_LOSS

  • Service 22DID 100F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Environment data camshaft input 1 TAIGO_PQ35_ENVD_CAM_IN_1

  • Service 22DID 1213
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Excessive temperature protection TAIGO_EXCESSIVE_T

  • Service 22DID 2117
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Exhaust camshaft, adaptation bias TAIGO_EXH_CAM_ADPT_BIAS

  • Service 22DID 174A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720 to 719 °
Unit
°

In testing for 2021 to 2026.

Exhaust camshaft, adaptation sensor tolerance TAIGO_EXH_CAM_ADPT_SENS

  • Service 22DID 1755
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720 to 719 °
Unit
°

In testing for 2021 to 2026.

Exhaust gas jet volume in particle filter TAIGO_EXH_GAS_JET_VOLUME

  • Service 22DID 3D7E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700 L
Unit
L

In testing for 2021 to 2026.

Exhaust gas recirculation valve 2 bank 1 mass flow TAIGO_MQB_EGR_VALVE_2_B1_FLOW

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2021 to 2026.

Exhaust gas recirculation valve duty TAIGO_PQ35_EGR_DUTY

  • Service 22DID 10C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Exhaust gas temperature TAIGO_EXH_GAS_T

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2021 to 2026.

Exhaust gas temperature - calculated after catalyst TAIGO_EXH_GAS_T_CALC_AFTER

  • Service 22DID 2AE9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29312500−273.15
Range
-273.15 to 1262.9904 °C
Unit
°C

In testing for 2021 to 2026.

Exhaust gas temperature before catalyst TAIGO_EXHAUST_GAS_T_BEFORE_CATALYST

  • Service 22DID 1282
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50−193.93
Range
-193.93 to 1116.77 °C
Unit
°C

In testing for 2021 to 2026.

Exhaust gas temperature before catalytic converter TAIGO_EXH_GAS_T_BEFORE

  • Service 22DID 296F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2021 to 2026.

Exhaust gas temperature sensor 1 TAIGO_EXH_GAS_T_SENS_1

  • Service 22DID 2976
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2021 to 2026.

Exhaust gas temperature sensor 1 TAIGO_PQ35_EXH_GAS_T_1

  • Service 22DID 10FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2021 to 2026.

Exhaust gas temperature sensor 2 TAIGO_PQ35_EXHAUST_GAS_T_SENSOR_2

  • Service 22DID 14F7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2021 to 2026.

Exhaust gas temperature sensor 4 TAIGO_EXH_GAS_T_SENS_4

  • Service 22DID 166D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2021 to 2026.

Exhaust gas temperature, sensor 4, bank 2 TAIGO_EXH_GAS_T_S4_B2

  • Service 22DID 166E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2021 to 2026.

Exhaust temperature before the catalyst, modeled TAIGO_EXH_T_BEFORE_CAT

  • Service 22DID 1421
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Exhaust temperature control downstream oxidation catalyst filtered model error TAIGO_MQB_EXH_TEMP_CTRL_AFTER_CAT_MODEL_ERR

  • Service 22DID 1AD7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Field limit value TAIGO_PQ35_FIELD_LIM

  • Service 22DID 11F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2021 to 2026.

Field regeneration request status TAIGO_FIELD_REGEN_REQ_STAT

  • Service 22DID 2087
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Fuel temperature TAIGO_PQ35_FUEL_T

  • Service 22DID 162D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Generator load normalized value TAIGO_GENERATOR_LOAD_NORMALIZED_VALUE_7E0

  • Service 22DID 15CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Generator load signal TAIGO_GEN_LOAD_SIG

  • Service 22DID 2050
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Generator load signal TAIGO_GEN_LOAD_SIG_7E0

  • Service 22DID 1033
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2021 to 2026.

Generator power TAIGO_GEN_POWER

  • Service 22DID 1097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9.4247
Range
0 to 617647.7145 W
Unit
W

In testing for 2021 to 2026.

Generator torque request TAIGO_GENERATOR_TORQUE_REQUEST_7E0

  • Service 22DID 101B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Heater circulation pump, nominal value TAIGO_HEATER_CIRCULATION

  • Service 22DID 167F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Heater support pump, specified value TAIGO_HEATER_SUPPORT_PMP_SPEC

  • Service 22DID 4336
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Height correction TAIGO_HEIGHT_CORR

  • Service 22DID 1136
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000610348
Range
0 to 3.9999
Unit
Number

In testing for 2021 to 2026.

High pressure control, adaptation TAIGO_HIGH_P_CTRL_ADPT

  • Service 22DID 11D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2021 to 2026.

High pressure EGR actuator, activation TAIGO_HIGH_P_EGR_ACTUATOR

  • Service 22DID 1334
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2021 to 2026.

High pressure regulation, adaptation value TAIGO_HIGH_P_REGULATION

  • Service 22DID 4384
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2021 to 2026.

Hybrid temperature TAIGO_MQB_TCM_HYBRID_T

  • Service 22DID 1196
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2021 to 2026.

ID of current driving program TAIGO_ID_CURRENT_DRIVING

  • Service 22DID 1012
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

IGA_CYL_KNK, 0 TAIGO_IGA_CYL_KNK_0

  • Service 22DID 13F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2021 to 2026.

IGA_CYL_KNK, 1 TAIGO_IGA_CYL_KNK_1

  • Service 22DID 13F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2021 to 2026.

IGA_CYL_KNK, 2 TAIGO_IGA_CYL_KNK_2

  • Service 22DID 13F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2021 to 2026.

IGA_CYL_KNK, 3 TAIGO_IGA_CYL_KNK_3

  • Service 22DID 13F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2021 to 2026.

IGA_IGC, 0 TAIGO_IGA_IGC_0

  • Service 22DID 138A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2021 to 2026.

IGA_IGC, 1 TAIGO_IGA_IGC_1

  • Service 22DID 138B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2021 to 2026.

IGA_IGC, 2 TAIGO_IGA_IGC_2

  • Service 22DID 138C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2021 to 2026.

IGA_IGC, 3 TAIGO_IGA_IGC_3

  • Service 22DID 138D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2021 to 2026.

Ignition angle current cylinder, actual value TAIGO_IGN_ANG_CURRENT_CYL_ACT

  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-25 to 25 °
Unit
°

In testing for 2021 to 2026.

Injection amount deviation cylinder 1 TAIGO_INJ_AMOUNT_DEV_CYL_1

  • Service 22DID 2046
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2021 to 2026.

Injection amount deviation cylinder 1 TAIGO_PQ35_INJ_DEV_CYL_1

  • Service 22DID 10FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2021 to 2026.

Injection amount deviation cylinder 2 TAIGO_INJ_AMOUNT_DEV_CYL_2

  • Service 22DID 2047
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2021 to 2026.

Injection amount deviation cylinder 2 TAIGO_PQ35_INJ_DEV_CYL_2

  • Service 22DID 1105
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2021 to 2026.

Injection amount deviation cylinder 3 TAIGO_INJ_AMOUNT_DEV_CYL_3

  • Service 22DID 2048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2021 to 2026.

Injection amount deviation cylinder 3 TAIGO_PQ35_INJ_DEV_CYL_3

  • Service 22DID 1100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2021 to 2026.

Injection amount deviation cylinder 4 TAIGO_INJ_AMOUNT_DEV_CYL_4

  • Service 22DID 2049
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.00036623
Range
-12 to 12
Unit
Raw value

In testing for 2021 to 2026.

Injection amount deviation cylinder 4 TAIGO_PQ35_INJ_DEV_CYL_4

  • Service 22DID 1104
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2021 to 2026.

Injection quantity deviation, cylinder 2 TAIGO_INJ_QTY_DEV_CYL_2

  • Service 22DID 204A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2021 to 2026.

Injection quantity deviation, cylinder 5 TAIGO_INJ_QTY_DEV_CYL_5

  • Service 22DID 204B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2021 to 2026.

Injector 1 rail pressure calibration point 1 TAIGO_PQ35_INJ_1_RAIL_P_1

  • Service 22DID 10D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2021 to 2026.

Injector 1 rail pressure calibration point 2 TAIGO_PQ35_INJ_1_RAIL_P_2

  • Service 22DID 10D6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2021 to 2026.

Injector 1 rail pressure calibration point 3 TAIGO_PQ35_INJ_1_RAIL_P_3

  • Service 22DID 10DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2021 to 2026.

Injector 2 rail pressure calibration point 1 TAIGO_PQ35_INJ_2_RAIL_P_1

  • Service 22DID 10D3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2021 to 2026.

Injector 2 rail pressure calibration point 2 TAIGO_PQ35_INJ_2_RAIL_P_2

  • Service 22DID 10D9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2021 to 2026.

Injector 2 rail pressure calibration point 3 TAIGO_PQ35_INJ_2_RAIL_P_3

  • Service 22DID 10DF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2021 to 2026.

Injector 2: rail pressure calibration point 1 TAIGO_INJ_2_RAIL_P_CAL_PT_1_146E

  • Service 22DID 146E
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2021 to 2026.

Injector 2: rail pressure calibration point 2 TAIGO_INJ_2_RAIL_P_CAL_PT_2_1474

  • Service 22DID 1474
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2021 to 2026.

Injector 2: rail pressure calibration point 3 TAIGO_INJ_2_RAIL_P_CAL_PT_3_147A

  • Service 22DID 147A
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2021 to 2026.

Injector 3 rail pressure calibration point 1 TAIGO_PQ35_INJ_3_RAIL_P_1

  • Service 22DID 10D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2021 to 2026.

Injector 3 rail pressure calibration point 2 TAIGO_PQ35_INJ_3_RAIL_P_2

  • Service 22DID 10D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2021 to 2026.

Injector 3 rail pressure calibration point 3 TAIGO_PQ35_INJ_3_RAIL_P_3

  • Service 22DID 10DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2021 to 2026.

Injector 4 rail pressure calibration point 2 TAIGO_PQ35_INJ_4_RAIL_P_2

  • Service 22DID 10D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2021 to 2026.

Injector 4 rail pressure calibration point 3 TAIGO_PQ35_INJ_4_RAIL_P_3

  • Service 22DID 10DE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

In testing for 2021 to 2026.

Injector 7: rail pressure calibration point 1 TAIGO_INJ_7_RAIL_P_CAL_PT_1

  • Service 22DID 146D
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2021 to 2026.

Injector 7: rail pressure calibration point 2 TAIGO_INJ_7_RAIL_P_CAL_PT_2

  • Service 22DID 1473
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2021 to 2026.

Injector 7: rail pressure calibration point 3 TAIGO_INJ_7_RAIL_P_CAL_PT_3

  • Service 22DID 1479
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2021 to 2026.

Inlet flaps - actual value TAIGO_INLET_FLAPS_ACT

  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Inlet flaps - requested value TAIGO_INLET_FLAPS_REQ

  • Service 22DID 11A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022. Supported for 2023.

Intake air temperature TAIGO_IAT_7E0

  • Service 22DID 1001
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2021 to 2026.

Intake air temperature before throttle valve, raw value TAIGO_IAT_BEFORE_THROTTLE

  • Service 22DID 15C1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×75100−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2021 to 2026.

Intake air temperature in intake manifold TAIGO_INTAKE_AIR_T_IN_INTAKE_MANIFOLD_7E0

  • Service 22DID 149E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2021 to 2026.

Intake air temperature in intake manifold raw value TAIGO_IAT_INT_MANIFOLD_RAW

  • Service 22DID 15C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2021 to 2026.

Intake camshaft adaptation unit 1 phase length TAIGO_PQ35_CAMS_ADAPT_PHASE_1

  • Service 22DID 12FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2021 to 2026.

Intake camshaft signal edge position adapted edge 2 TAIGO_PQ35_CAMS_EDGE_POS_2

  • Service 22DID 1189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2021 to 2026.

Intake camshaft signal edge position adapted edge 3 TAIGO_PQ35_CAMS_EDGE_POS_3

  • Service 22DID 118A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2021 to 2026.

Intake camshaft signal edge position adapted edge 4 TAIGO_PQ35_CAMS_EDGE_POS_4

  • Service 22DID 118B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2021 to 2026.

Intake camshaft signal edge position adapted edge 5 TAIGO_PQ35_CAMS_EDGE_POS_5

  • Service 22DID 118C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2021 to 2026.

Intake camshaft signal edge position adapted edge 6 TAIGO_PQ35_CAMS_EDGE_POS_6

  • Service 22DID 118D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2021 to 2026.

Intake camshaft signal edge position adapted edge 7 TAIGO_PQ35_CAMS_EDGE_POS_7

  • Service 22DID 118E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2021 to 2026.

Intake camshaft signal edge position adapted edge 8 TAIGO_PQ35_CAMS_EDGE_POS_8

  • Service 22DID 118F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2021 to 2026.

Intake camshaft signal edge position adapted value edge 1 TAIGO_PQ35_INTAKE_CAMSHAFT_SIGNAL_EDGE_POS_ADAPTED_VALUE_EDGE_1

  • Service 22DID 173A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−32
Range
-32 to 4063.9375 °
Unit
°

In testing for 2021 to 2026.

Intake camshaft, adaptation bias TAIGO_INT_CAM_ADPT_BIAS

  • Service 22DID 174B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720 to 719 °
Unit
°

In testing for 2021 to 2026.

Intake camshaft, adaptation sensor tolerance TAIGO_INT_CAM_ADPT_SENS

  • Service 22DID 1740
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720 to 719 °
Unit
°

In testing for 2021 to 2026.

Intake manifold pressure calculated TAIGO_MQB_INT_MAN_P

  • Service 22DID 103C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2021 to 2026.

Intake manifold pressure raw value TAIGO_INT_MANIFOLD_P_RAW

  • Service 22DID 11DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×781.2510000
Range
0 to 19.92
Unit
Raw value

In testing for 2021 to 2026.

Intake manifold pressure raw value TAIGO_INT_MANIFOLD_P_RAW_7E0

  • Service 22DID 3E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2021 to 2026.

Intake manifold pressure, commanded TAIGO_INT_MANIFOLD_P_CMD

  • Service 22DID 11DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.078125
Range
0 to 5119
Unit
Raw value

In testing for 2021 to 2026.

Intake manifold pressure, corrected TAIGO_INT_MANIFOLD_P

  • Service 22DID 11DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.078125
Range
0 to 5119
Unit
Raw value

In testing for 2021 to 2026.

Intake manifold runner control, acknowledgment TAIGO_INT_MANIFOLD_RUNNER_CTRL

  • Service 22DID 206A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Intake manifold runner control, activation TAIGO_INT_MANIFOLD_RUNNER

  • Service 22DID 2069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Intake model air mass flow filtered value TAIGO_INT_MODEL_AIR_MASS

  • Service 22DID 11AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2021 to 2026.

Intake phase deviation, actual value TAIGO_INT_PHASE_DEV_ACT

  • Service 22DID 1800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2021 to 2026.

Integrated mass of air since engine start TAIGO_INTEGRATED_MASS_AIR

  • Service 22DID 1175
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2021 to 2026.

Integrated mass of air since the first engine start TAIGO_INTEGRATED_MASS_AIR_SINCE

  • Service 22DID 1743
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2021 to 2026.

Intercooler air output temperature TAIGO_PQ35_INTERCOOLER_AIR_OUTPUT_T

  • Service 22DID 1628
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Kick down TAIGO_MQB_TCM_KICK_DOWN

  • Service 22DID 2114
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Kilometers driven since last event on K1 TAIGO_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1

  • Service 22DID 115A
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

In testing for 2021 to 2026.

Kilometers driven since last event on K2 TAIGO_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2

  • Service 22DID 115C
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

In testing for 2021 to 2026.

Knock retard 2 TAIGO_KNOCK_RETARD_2

  • Service 22DID 10E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

In testing for 2021 to 2026.

Knock retard 2,, variant 1 TAIGO_KNOCK_RETARD_2_VAR_1

  • Service 22DID 10E5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2021 to 2026.

Knock sensor 1 test TAIGO_KNOCK_SENS_1_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

Knock sensor 2 test TAIGO_KNOCK_SENS_2_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

Knock sensor 3 test TAIGO_KNOCK_SENS_3_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

Knock sensor 4 test TAIGO_KNOCK_SENS_4_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

Knock sensor based camshaft angle adjustment counter TAIGO_KNOCK_CAM_ANG_ADJ

  • Service 22DID 523B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Knock sensor, cylinder 1 TAIGO_KNOCK_SENS_CYL_1

  • Service 22DID 120E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048489933
Range
0 to 317 V
Unit
V

In testing for 2021 to 2026.

Knock sensor, cylinder 1, variant 2 TAIGO_KNOCK_SENS_CYL_1_VAR_2

  • Service 22DID 3960
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2021 to 2026.

Knock sensor, cylinder 2 TAIGO_KNOCK_SENS_CYL_2

  • Service 22DID 1211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048489933
Range
0 to 317 V
Unit
V

In testing for 2021 to 2026.

Knock sensor, cylinder 2 TAIGO_KNOCK_SENS_CYL_2_7E0

  • Service 22DID 1212
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×7.62e-7
Range
0 to 3272
Unit
Number

In testing for 2021 to 2026.

Knock sensor, cylinder 2, variant 2 TAIGO_KNOCK_SENS_CYL_2_VAR_2

  • Service 22DID 3961
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2021 to 2026.

Knock sensor, cylinder 3 TAIGO_KNOCK_SENS_CYL_3

  • Service 22DID 120F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048489933
Range
0 to 317 V
Unit
V

In testing for 2021 to 2026.

Knock sensor, cylinder 3, variant 2 TAIGO_KNOCK_SENS_CYL_3_VAR_2

  • Service 22DID 3962
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2021 to 2026.

Knock sensor, cylinder 4 TAIGO_KNOCK_SENS_CYL_4

  • Service 22DID 1210
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048489933
Range
0 to 317 V
Unit
V

In testing for 2021 to 2026.

Knock sensor, cylinder 4, variant 2 TAIGO_KNOCK_SENS_CYL_4_VAR_2

  • Service 22DID 3963
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2021 to 2026.

Lambda output value TAIGO_LAMBDA_OUTPUT

  • Service 22DID 15D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.99
Unit
Number

In testing for 2021 to 2026.

Lambda, actual value TAIGO_LAMBDA_ACT

  • Service 22DID 10D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1220750000000
Range
-7.9999 to 7.9997
Unit
Number

In testing for 2021 to 2026.

Launch control counter, variant 1 TAIGO_LAUNCH_CTRL_CNT_VAR_1

  • Service 22DID 1200
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Launch control counter, variant 2 TAIGO_LAUNCH_CTRL_CNT_VAR_2

  • Service 22DID 38F1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2022. Supported for 2023.

Long term fuel trim at idle, direct injection TAIGO_LONG_TERM_FUEL_TRIM_IDLE

  • Service 22DID 177E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2021 to 2026.

Long term fuel trim at idle, port injection TAIGO_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ

  • Service 22DID 1780
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2021 to 2026.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2022.

Long term throttle adaptation to MAF sensor TAIGO_LONG_TERM_THROTTLE

  • Service 22DID 113A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000610351
Range
0 to 3.99 %
Unit
%

In testing for 2021 to 2026.

Long-term adaptation of intake manifold injection TAIGO_LONG_TERM_ADPT_INT

  • Service 22DID 414E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2021 to 2026.

Long-term adaptation of intake manifold injection at idle TAIGO_LONG_TERM_ADPT_INT_MANIFOLD_INJ

  • Service 22DID 414F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2021 to 2026.

Lost torque adaptation A/C + driving mode TAIGO_LOST_TQ_ADPT_AC

  • Service 22DID 437F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2021 to 2026.

Lost torque adaptation driving mode TAIGO_LOST_TQ_ADPT_DRIVING

  • Service 22DID 437E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2021 to 2026.

Low press. EGR closing TAIGO_LOW_PRESS_EGR

  • Service 22DID 406B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Low pressure EGR closing TAIGO_LOW_P_EGR_CLOSING

  • Service 22DID 17F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×-252048+100
Range
-699 to 100 %
Unit
%

In testing for 2021 to 2026.

Lower adapted coupling point K2 from micro-slip path adaptation TAIGO_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPT

  • Service 22DID 110A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2021 to 2026.

M009, desired solenoid out 10 TAIGO_M009_DES_SOLENOID_10

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

M009, desired solenoid out 11 TAIGO_M009_DES_SOLENOID_11

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

M009, desired solenoid out 12 TAIGO_M009_DES_SOLENOID_12

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

M009, desired solenoid out 13 TAIGO_M009_DES_SOLENOID_13

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

M009, desired solenoid out 14 TAIGO_M009_DES_SOLENOID_14

  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

Main catalyst aging factor TAIGO_MAIN_CAT_AGING

  • Service 22DID 14F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.30517586100000
Range
0 to 0.199
Unit
Number

In testing for 2021 to 2026.

Main injection duration TAIGO_PQ35_MAIN_INJ_DURATION

  • Service 22DID 14CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2021 to 2026.

Main injection start position TAIGO_PQ35_MAIN_INJ_START

  • Service 22DID 11F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2021 to 2026.

Mass air flow over throttle valve TAIGO_MAF_OVER_THROTTLE

  • Service 22DID 394F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2021 to 2026.

Mass air flow rate TAIGO_MAF_RATE

  • Service 22DID 13CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047
Unit
Raw value

In testing for 2021 to 2026.

Mass air flow through throttle TAIGO_MAF_THROUGH_THROTTLE

  • Service 22DID 11AC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2021 to 2026.

Mass air flow, commanded TAIGO_MAF_CMD

  • Service 22DID 11AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2021 to 2026.

Mass airflow sensor 1 bank 1 raw value TAIGO_MQB_MAF_1_B1_RAW

  • Service 22DID 1026
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2021 to 2026.

Mass flow through throttle valve TAIGO_MASS_FLOW_THROUGH

  • Service 22DID 110A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2021 to 2026.

Max permissible engine torque TAIGO_MAX_PERMISSIBLE_ENG

  • Service 22DID 211A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2021 to 2026.

Maximum ECU temperature TAIGO_MAX_ECU_T

  • Service 22DID 4649
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Maximum filling correction factor from knock control TAIGO_MAX_FILLING_CORR

  • Service 22DID 10E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3100000
Range
0 to 1.96
Unit
Number

In testing for 2021 to 2026.

Maximum oil level for the service interval TAIGO_MAX_OIL_LEVEL

  • Service 22DID 1230
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2021 to 2026.

Mean engine air mass TAIGO_MEAN_ENG_AIR_MASS

  • Service 22DID 2032
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2021 to 2026.

Mean engine air mass TAIGO_PQ35_MEAN_AIR_MASS

  • Service 22DID 1314
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047
Unit
Raw value

In testing for 2021 to 2026.

Mean injection quantity TAIGO_MEAN_INJ_QTY

  • Service 22DID 2097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2021 to 2026.

Mean injection quantity TAIGO_MEAN_INJ_QUANTITY

  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2021 to 2026.

Mileage with ECU installed TAIGO_MILEAGE_ECU

  • Service 22DID 10A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2021 to 2026.

Minimum oil level for the service interval TAIGO_MIN_OIL_LEVEL

  • Service 22DID 1231
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2021 to 2026.

Misfires / 1000 revolutions, cylinder 1 TAIGO_MISFIRES_1000REV_C1

  • Service 22DID 1147
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires / 1000 revolutions, cylinder 2 TAIGO_MISFIRES_1000REV_C2

  • Service 22DID 114A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires / 1000 revolutions, cylinder 3 TAIGO_MISFIRES_1000REV_C3

  • Service 22DID 1148
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires / 1000 revolutions, cylinder 4 TAIGO_MISFIRES_1000REV_C4

  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires counter:, cylinder 2 TAIGO_MIS_CNT_2

  • Service 22DID 1482
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires counter:, cylinder 3 TAIGO_MIS_CNT_3

  • Service 22DID 1480
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires counter:, cylinder 5 TAIGO_MIS_CNT_5

  • Service 22DID 1483
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires per 1000 revolutions 4 TAIGO_MIS_PER_1000_REVOLUTIONS_4_7E0

  • Service 22DID 114C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires per 1000 revolutions, cylinder 1, port injection TAIGO_MIS_PER_1000_1

  • Service 22DID 426B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires per 1000 revolutions, cylinder 2 TAIGO_MIS_PER_1000_2_7E0

  • Service 22DID 10F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires per 1000 revolutions, cylinder 2, port injection TAIGO_MIS_PER_1000_2

  • Service 22DID 426C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires per 1000 revolutions, cylinder 3 TAIGO_MIS_PER_1000_3_7E0

  • Service 22DID 10F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires per 1000 revolutions, cylinder 3, port injection TAIGO_MIS_PER_1000_3

  • Service 22DID 426D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires per 1000 revolutions, cylinder 4, port injection TAIGO_MIS_PER_1000_4

  • Service 22DID 426E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires total TAIGO_MIS_TOT

  • Service 22DID 2904
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires total TAIGO_MISFIRES_TOTAL

  • Service 22DID 1146
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires, cylinder 1 TAIGO_MIS_1

  • Service 22DID 10F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires, cylinder 1 TAIGO_MISFIRES_C1

  • Service 22DID 114F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires, cylinder 1,, variant 2 TAIGO_MIS_VAR_2_1

  • Service 22DID 2966
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires, cylinder 2 TAIGO_MIS_2

  • Service 22DID 10FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires, cylinder 2,, variant 2 TAIGO_MIS_VAR_2

  • Service 22DID 2967
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires, cylinder 3 TAIGO_MIS_3

  • Service 22DID 10F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires, cylinder 3 TAIGO_MISFIRES_C3

  • Service 22DID 1150
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires, cylinder 3,, variant 2 TAIGO_MIS_VAR_2_3

  • Service 22DID 2968
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires, cylinder 4 TAIGO_MIS_4

  • Service 22DID 10F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires, cylinder 4,, variant 2 TAIGO_MIS_VAR_2_4

  • Service 22DID 2969
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Mixture adaptation factor at partial load TAIGO_MIXTURE_ADPT_FACTOR

  • Service 22DID 3996
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2021 to 2026.

N_32 TAIGO_N_32

  • Service 22DID 117D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2021 to 2026.

NL_PRE, 0 TAIGO_NL_PRE_0

  • Service 22DID 13F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2021 to 2026.

NL_PRE, 1 TAIGO_NL_PRE_1

  • Service 22DID 13F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2021 to 2026.

NL_PRE, 2 TAIGO_NL_PRE_2

  • Service 22DID 13F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2021 to 2026.

NL_PRE, 3 TAIGO_NL_PRE_3

  • Service 22DID 13F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2021 to 2026.

Number of automatic engine starts TAIGO_NUM_AUTOMATIC_ENG

  • Service 22DID 2999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Number of engine starts, manual TAIGO_NUM_ENG_STARTS

  • Service 22DID 2998
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Number of injections TAIGO_NUM_INJECTIONS

  • Service 22DID 430E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Number of times the permitted centrifugal oil temperature has been exceeded TAIGO_NUM_TIMES_PERMITTED_T

  • Service 22DID 1154
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Number of warnings due to increased centrifugal oil temperature TAIGO_NUM_WARN_HI_CENTRIF_T

  • Service 22DID 1155
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Oil ash limit TAIGO_OIL_ASH_LIM

  • Service 22DID 1793
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2021 to 2026.

Oil ash residue TAIGO_OIL_ASH_RESIDUE

  • Service 22DID 208A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×3.052e-7
Range
0 to 1310
Unit
Raw value

In testing for 2021 to 2026.

Oil ash residue TAIGO_OIL_ASH_RESIDUE_7E0

  • Service 22DID 406C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2021 to 2026.

Oil ash residue TAIGO_PQ35_OIL_ASH_RESIDUE

  • Service 22DID 178C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2021 to 2026.

Oil dynamic average measurement TAIGO_PQ35_OIL_DYN_AVG

  • Service 22DID 123F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2021 to 2026.

Oil fill level TAIGO_PQ35_OIL_FILL_LEVEL

  • Service 22DID 2006
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.06
Range
-1966.08 to 1966.02 mm
Unit
mm

In testing for 2021 to 2026.

Oil last dynamic measurement TAIGO_PQ35_OIL_DYN_LAST

  • Service 22DID 123C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2021 to 2026.

Oil level TAIGO_OIL_LEVELConfirmed

  • Service 22DID 11BA
  • Module7E0
  • Every5 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

0x009D = 157 → 1572500 = 0.0628 cm

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Oil level method 1 TAIGO_OIL_LEVEL_METHOD_1

  • Service 22DID 1AF9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2021 to 2026.

Oil level method 2 TAIGO_OIL_LEVEL_METHOD_2

  • Service 22DID 1AFA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2021 to 2026.

Oil level method 3 TAIGO_OIL_LEVEL_METHOD_3

  • Service 22DID 1AFB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2021 to 2026.

Oil level test method 1 TAIGO_OIL_LEVEL_TEST_1

  • Service 22DID 4E51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2021 to 2026.

Oil level test method 2 TAIGO_OIL_LEVEL_TEST_2

  • Service 22DID 4E52
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2021 to 2026.

Oil level test method 3 TAIGO_OIL_LEVEL_TEST_3

  • Service 22DID 4E53
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2021 to 2026.

Oil level, average dynamic value TAIGO_OIL_LEVEL_AVG

  • Service 22DID 15B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2021 to 2026.

Oil level, static measured TAIGO_OIL_LEVEL_STATIC

  • Service 22DID 15A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2021 to 2026.

Oil level, static measurement TAIGO_OIL_LEVEL_STATIC_7E0

  • Service 22DID 40CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−127
Range
-127 to 3968 mm
Unit
mm

In testing for 2021 to 2026.

Oil p TAIGO_OIL_P

  • Service 22DID 25CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2021 to 2026.

Oil pressure actual TAIGO_MQB_TCM_EOP_ACTUAL

  • Service 22DID 381D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 bar
Unit
bar

In testing for 2021 to 2026.

Oil pressure actual current TAIGO_MQB_TCM_EOP_ACTUAL_I

  • Service 22DID 381E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2021 to 2026.

Oil pressure control valve activation pulse duty factor TAIGO_OIL_P_CTRL_VLV

  • Service 22DID 25D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2021 to 2026.

Oil pressure control valve, activation pulse duty factor TAIGO_OIL_P_CTRL_VLV_ACTIVATION

  • Service 22DID 4F97
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2021 to 2026.

Oil pressure sensor raw value TAIGO_OIL_P_SENS_RAW

  • Service 22DID 4FBE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2021 to 2026.

Oil pressure sensor-piston cooling nozzle switch, status TAIGO_OIL_P_SENS_PISTON

  • Service 22DID 15BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Oil pressure sensor, raw value TAIGO_OIL_P_SENS_RAW_7E0

  • Service 22DID 1B02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Oil pressure switch activation, high pressure TAIGO_OIL_P_SWITCH_P

  • Service 22DID 20A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Oil pressure switch for high pressure, closed TAIGO_OIL_P_SWITCH_HIGH_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

Oil pressure switch for low pressure, closed TAIGO_OIL_P_SWITCH_LOW_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

Oil pressure switch for piston-cooling jets, closed TAIGO_OIL_P_SWITCH_PISTON

  • Service 22DID 4270
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Oil pressure switch valve activation TAIGO_OIL_P_SWITCH_VLV

  • Service 22DID 13B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Oil pressure target TAIGO_OIL_P_TGT

  • Service 22DID 4F70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 2021 to 2026.

Oil pressure target TAIGO_OIL_P_TGT_7E0

  • Service 22DID 25CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2021 to 2026.

Oil pressure valve for piston cooling nozzles, control switch button ratio TAIGO_OIL_P_VLV_PISTON

  • Service 22DID 2CD8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2021 to 2026.

Oil pressure valve switch, control TAIGO_OIL_P_VLV_SWITCH

  • Service 22DID 11B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Oil pressure, actual value TAIGO_OIL_P_ACT_7E0

  • Service 22DID 177D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2021 to 2026.

Oil pressure, actual value TAIGO_OIL_P_ACT_7E0_2

  • Service 22DID 1B04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2021 to 2026.

Oil pressure, actual value TAIGO_OIL_P_ACT_7E0_2_7E0

  • Service 22DID 381D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2021 to 2026.

Oil temp 2 TAIGO_PQ35_ENGINE_OIL_T_2

  • Service 22DID 179C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Oil temperature TAIGO_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 10A7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2021 to 2026.

Oil warning threshold TAIGO_OIL_WARN_THR

  • Service 22DID 2007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mm
Unit
mm

In testing for 2021 to 2026.

Open cam shaft angle at quantity control valve TAIGO_OPEN_CAM_SHFT_ANG

  • Service 22DID 10EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2021 to 2026.

Oxygen control, adaptation value at part. load TAIGO_OXYGEN_CTRL_ADPT

  • Service 22DID 39A9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2021 to 2026.

Oxygen sensor 1 bank 1 ceramic temperature TAIGO_OXYGEN_SNS_1_BANK_1_CERAMIC_T_7E0

  • Service 22DID 1290
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×234.3710000−273.15
Range
-273.15 to 1262.793 °C
Unit
°C

In testing for 2021 to 2026.

Oxygen sensor 1 bank 1 lambda value TAIGO_PQ35_O2_SEN_1_LAMBDA

  • Service 22DID 113D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Number

In testing for 2021 to 2026.

Particle filter, field regeneration request status TAIGO_PARTICLE_FLT_FIELDConfirmed

  • Service 22DID 115B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Particle sensor, time in op.mode measurement TAIGO_PARTICLE_SENS_TIME

  • Service 22DID 46D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 s
Unit
s

In testing for 2021 to 2026.

Pilot injection 1 duration TAIGO_PQ35_PRE_INJ_1_DURATION

  • Service 22DID 14D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2021 to 2026.

Pilot injection 1 start position TAIGO_PQ35_PRE_INJ_1_START

  • Service 22DID 14C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2021 to 2026.

Pilot injection 1, activation start TAIGO_PRE_INJ_1_ACTIVATION

  • Service 22DID 12C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2021 to 2026.

Pilot injection 2 duration TAIGO_PQ35_PRE_INJ_2_DURATION

  • Service 22DID 14D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2021 to 2026.

Pilot injection 2 start TAIGO_PQ35_PRE_INJ_2_START

  • Service 22DID 14C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2021 to 2026.

Pilot injection 2, activation start TAIGO_PRE_INJ_2_ACTIVATION

  • Service 22DID 12C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2021 to 2026.

Pilot injection 3 start TAIGO_PRE_INJ_3_START

  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×219731000000
Range
-720 to 719 °
Unit
°

In testing for 2021 to 2026.

Pilot injection 3, activation duration TAIGO_PRE_INJ_3_ACTIVATION

  • Service 22DID 121A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2021 to 2026.

Pilot injection 3, activation start TAIGO_PRE_INJ_3_ACTIVATION_START

  • Service 22DID 121D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 °
Unit
°

In testing for 2021 to 2026.

Piston cooling nozzles, control TAIGO_PISTON_COOLING

  • Service 22DID 16F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Piston-cooling jets, activation TAIGO_PISTON_COOLING_JETS

  • Service 22DID 4286
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Port injection injections counter TAIGO_PORT_INJ_INJECTIONS

  • Service 22DID 4268
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2021 to 2026.

Post injection 1 TAIGO_POST_INJ_1

  • Service 22DID 081A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2021 to 2026.

Post injection 1 TAIGO_POST_INJ_1_7E0

  • Service 22DID 205D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2021 to 2026.

Post injection 1: quantity specified value TAIGO_PQ35_POST_INJ_1_QTY_SPEC

  • Service 22DID 163C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2021 to 2026.

Post injection 2 TAIGO_POST_INJ_2

  • Service 22DID 080C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2021 to 2026.

Post injection 2 TAIGO_POST_INJ_2_7E0

  • Service 22DID 205F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2021 to 2026.

Post injection 2: quantity specified value TAIGO_PQ35_POST_INJ_2_QTY_SPEC

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2021 to 2026.

Post injection 3 TAIGO_POST_INJ_3

  • Service 22DID 081B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2021 to 2026.

Post injection 3 TAIGO_POST_INJ_3_7E0

  • Service 22DID 20C0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2021 to 2026.

Post injection 3: quantity specified value TAIGO_PQ35_POST_INJ_3_QTY_SPEC

  • Service 22DID 167D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2021 to 2026.

Post-injection 1 duration TAIGO_PQ35_POST_INJ_1_DURATION

  • Service 22DID 14CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2021 to 2026.

Post-injection 1 start position TAIGO_PQ35_POST_INJ_1_START

  • Service 22DID 11F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2021 to 2026.

Post-injection 2 duration TAIGO_PQ35_POST_INJ_2_DURATION

  • Service 22DID 14CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2021 to 2026.

Post-injection 2 start position TAIGO_PQ35_POST_INJ_2_START

  • Service 22DID 11F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2021 to 2026.

Post-injection 2, activation duration TAIGO_POST_INJ_2_7E0_7E0

  • Service 22DID 121B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2500
Range
-13.1 to 13.1 ms
Unit
ms

In testing for 2021 to 2026.

Post-injection 3 activation duration TAIGO_PQ35_POST_INJ_3_ACTIVATION_DURATION

  • Service 22DID 14CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

In testing for 2021 to 2026.

Post-injection 3 start position TAIGO_PQ35_POST_INJ_3_START

  • Service 22DID 1131
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2021 to 2026.

Pressure before throttle valve - actual value TAIGO_P_BEFORE_THROTTLE_ACT

  • Service 22DID 11EE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2021 to 2026.

Pressure before throttle valve - sensor measured TAIGO_P_BEFORE_THROTTLE

  • Service 22DID 11EF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×21333546125
Range
0 to 2559.96
Unit
Raw value

In testing for 2021 to 2026.

Pressure sensor 1 temperature TAIGO_MQB_DL382_P_SENSOR_1_T

  • Service 22DID 132A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2021 to 2026.

Pressure sensor 2 temperature TAIGO_MQB_DL382_P_SENSOR_2_T

  • Service 22DID 132B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2021 to 2026.

Pressure supply actual pressure TAIGO_MQB_DQ200_P_SUPPLY_ACTUAL_P

  • Service 22DID 1191
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Pressure supply actual pressure analog digital value TAIGO_MQB_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUE

  • Service 22DID 102D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_1 TAIGO_PSN_EDGE_REL_AD_CAM_1

  • Service 22DID 1184
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2021 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_2 TAIGO_PSN_EDGE_REL_AD_CAM_2

  • Service 22DID 1185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2021 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_IN_1 TAIGO_PSN_EDGE_REL_AD_CAM_SAVE_1

  • Service 22DID 1186
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2021 to 2026.

Radiator fan 1, commanded duty TAIGO_RADIATOR_FAN_1_CMD

  • Service 22DID 109E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2021 to 2026.

Radiator fan 2, commanded duty TAIGO_RADIATOR_FAN_2_CMD

  • Service 22DID 109C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2021 to 2026.

Radiator outlet coolant temperature commanded TAIGO_PQ35_RAD_COOL_T_CMD

  • Service 22DID 1111
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Radiator output coolant temp: actual TAIGO_PQ35_RADIATOR_OUTPUT_COOLANT_T_ACTUAL

  • Service 22DID 1626
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2021 to 2026.

Rated drive torque TAIGO_RATED_DRIVE_TQ

  • Service 22DID 14A1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2021 to 2026.

Reached maximum temperature TAIGO_PQ35_REACHED_MAXIMUM_T

  • Service 22DID 1117
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2021 to 2026.

Reducing agent tank volume, act. value filtered TAIGO_REDUCING_AGENT_TANK_ACT

  • Service 22DID 1A6C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131 L
Unit
L

In testing for 2021 to 2026.

Regeneration duration TAIGO_REGEN_DUR

  • Service 22DID 39F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val60
Range
0 to 1092.25 min
Unit
min

In testing for 2021 to 2026.

Regulation factor total TAIGO_PQ35_REG_FACTOR

  • Service 22DID 10E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
0 to 3.276 %
Unit
%

In testing for 2021 to 2026.

Relative load value TAIGO_REL_LOAD

  • Service 22DID 1216
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234403081
Range
0 to 1536
Unit
Number

In testing for 2021 to 2026.

Relay for reserve coolant pump status TAIGO_RELAY_RESERVE_CLT

  • Service 22DID 3999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Requested torque, amount for auxiliary units TAIGO_REQ_TQ_AMOUNT

  • Service 22DID 10BE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Reserve torque TAIGO_RESERVE_TQ

  • Service 22DID 106A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2021 to 2026.

Result of crankcase ventilation test, fail TAIGO_RESULT_CRANKCASE_VENTILATION_TEST

  • Service 22DID 15CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Result of crankcase ventilation test, successful TAIGO_RESULT_CRANKCASE

  • Service 22DID 15CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Route data, active TAIGO_ROUTE_DATA_ACTIVE

  • Service 22DID 282C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Secondary air injection sensor 1 TAIGO_SECONDARY_AIR_INJ_1

  • Service 22DID 3F68
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2021 to 2026.

SEG_AD_MMV_ER_H, 0 TAIGO_SEG_AD_MMV_ER_H_0

  • Service 22DID 1138
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2021 to 2026.

SEG_AD_MMV_ER_H, 3 TAIGO_SEG_AD_MMV_ER_H_3

  • Service 22DID 113B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2021 to 2026.

SEG_AD_MMV_ER_L, 0 TAIGO_SEG_AD_MMV_ER_L_0

  • Service 22DID 113E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2021 to 2026.

SEG_AD_MMV_ER_L, 2 TAIGO_SEG_AD_MMV_ER_L_2

  • Service 22DID 1140
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2021 to 2026.

SEG_AD_MMV_ER_L, 3 TAIGO_SEG_AD_MMV_ER_L_3

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2021 to 2026.

SEG_AD_MMV_ER_MID, 0 TAIGO_SEG_AD_MMV_ER_MID_0

  • Service 22DID 1132
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2021 to 2026.

SEG_AD_MMV_ER_MID, 1 TAIGO_SEG_AD_MMV_ER_MID_1

  • Service 22DID 1133
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2021 to 2026.

SEG_AD_MMV_ER_MID, 2 TAIGO_SEG_AD_MMV_ER_MID_2

  • Service 22DID 1134
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2021 to 2026.

SEG_AD_MMV_ER, 2 TAIGO_SEG_AD_MMV_ER_2

  • Service 22DID 112E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2021 to 2026.

SEG_AD_MMV_ER, 3 TAIGO_SEG_AD_MMV_ER_3

  • Service 22DID 112F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2021 to 2026.

Sensor for particle filter differential pressure, raw value TAIGO_SENS_PARTICLE_FLT_P

  • Service 22DID 39E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2021 to 2026.

Service limit TAIGO_SERVICE_LIM

  • Service 22DID 20DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2021 to 2026.

Service limit TAIGO_SERVICE_LIM_7E0

  • Service 22DID 5851
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2021 to 2026.

Service limit value TAIGO_PQ35_SRV_LIM

  • Service 22DID 12CB
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2021 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2022. Supported for 2023.

Smoke limit TAIGO_PQ35_LIM_SMOKE

  • Service 22DID 1301
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Spark efficiency deviation at idle, maximum TAIGO_SPARK_EFFICIENCY_DEV_MAX

  • Service 22DID 155B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Spark efficiency deviation at part load TAIGO_SPARK_EFFICIENCY_DEV

  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×78.1100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Spark efficiency deviation at part load, maximum TAIGO_SPARK_EFFICIENCY_DEV_PART_MAX

  • Service 22DID 155C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Stop signal switch TAIGO_MQB_TCM_STOP_SIGNAL_SWITCH

  • Service 22DID 3800
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Sum of misfires counter TAIGO_SUM_MIS_CNT

  • Service 22DID 10F2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Tank fill level diagnostic reference value TAIGO_TANK_FILL_LEVEL

  • Service 22DID 51D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2021 to 2026.

TCO_1_ST TAIGO_TCO_1_ST

  • Service 22DID 11D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

TCO_1_SYS TAIGO_TCO_1_SYS

  • Service 22DID 11CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

Temperature at air conditioner heat exchanger output TAIGO_T_AC_HEAT_EXCHANGER

  • Service 22DID 1177
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2021 to 2026.

Temperature sensor for engine temperature management TAIGO_T_SENS_ENG_T

  • Service 22DID 392A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2021 to 2026.

Temperature sensor for engine temperature management, target value TAIGO_T_SENS_ENG_T_TGT

  • Service 22DID 40E2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2021 to 2026.

Test of catalytic converter status, canceled TAIGO_TEST_CATALYTIC_CONV_STAT

  • Service 22DID 2927
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Test of catalytic converter, measured value TAIGO_TEST_CATALYTIC_CONV

  • Service 22DID 2926
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535
Unit
Number

In testing for 2021 to 2026.

Thermostat, actual TAIGO_THERMOSTAT_ACT

  • Service 22DID 4418
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122.0710000
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Thermostat, commanded TAIGO_THERMOSTAT_CMD

  • Service 22DID 4417
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122.0710000
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Throttle regulator nominal value TAIGO_THROTTLE_REGULATOR

  • Service 22DID 16C5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Throttle valve adapter position TAIGO_PQ35_THROT_VALVE_ADAPT

  • Service 22DID 12FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

TI_1_MPI, 0 TAIGO_TI_1_MPI_0

  • Service 22DID 13AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_1_MPI, 1 TAIGO_TI_1_MPI_1

  • Service 22DID 13AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_1_MPI, 2 TAIGO_TI_1_MPI_2

  • Service 22DID 13AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_1_MPI, 3 TAIGO_TI_1_MPI_3

  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_MES4_PLS_1, 1 TAIGO_TI_MES4_PLS_1_1

  • Service 22DID 13A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_MES4_PLS_1, 2 TAIGO_TI_MES4_PLS_1_2

  • Service 22DID 13A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_MES4_PLS_1, 3 TAIGO_TI_MES4_PLS_1_3

  • Service 22DID 13A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_MES4_PLS_2, 0 TAIGO_TI_MES4_PLS_2_0

  • Service 22DID 13A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_MES4_PLS_2, 1 TAIGO_TI_MES4_PLS_2_1

  • Service 22DID 13A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_MES4_PLS_2, 2 TAIGO_TI_MES4_PLS_2_2

  • Service 22DID 13A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_MES4_PLS_2, 3 TAIGO_TI_MES4_PLS_2_3

  • Service 22DID 13A7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_MES4_PLS_3, 0 TAIGO_TI_MES4_PLS_3_0

  • Service 22DID 13A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_MES4_PLS_3, 1 TAIGO_TI_MES4_PLS_3_1

  • Service 22DID 13A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_MES4_PLS_3, 2 TAIGO_TI_MES4_PLS_3_2

  • Service 22DID 13AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

TI_MES4_PLS_3, 3 TAIGO_TI_MES4_PLS_3_3

  • Service 22DID 13AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2021 to 2026.

Time in after-run TAIGO_TIME_AFTERRUN

  • Service 22DID 103A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2021 to 2026.

Time since last regeneration TAIGO_TIME_SINCE_REGEN

  • Service 22DID 2089
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2021 to 2026.

Time since reset TAIGO_TIME_SINCE_RESET

  • Service 22DID 103B
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 2021 to 2026.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2022. Supported for 2023.

Timing angle retardation cylinder 1 TAIGO_PQ35_TIMING_ANGLE_RETARDATION_CYL_1

  • Service 22DID 200A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2021 to 2026.

Timing angle retardation cylinder 2 TAIGO_PQ35_TIMING_ANGLE_RETARDATION_CYL_2

  • Service 22DID 200B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2021 to 2026.

Timing angle retardation cylinder 3 TAIGO_PQ35_TIMING_ANGLE_RETARDATION_CYL_3

  • Service 22DID 200C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2021 to 2026.

Timing angle retardation cylinder 4 TAIGO_PQ35_TIMING_ANGLE_RETARDATION_CYL_4

  • Service 22DID 200D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.375−48
Range
-48 to 47.625 °
Unit
°

In testing for 2021 to 2026.

Timing deviation after chain replacement, exhaust bank 1 TAIGO_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1

  • Service 22DID 417D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2021 to 2026.

Timing deviation after chain replacement, intake bank 1 TAIGO_TIM_DEV_AFTER_CHAIN_1

  • Service 22DID 417B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2021 to 2026.

Timing deviation after other repairs, intake bank 1 TAIGO_TIM_DEV_AFTER_OTHER_1

  • Service 22DID 417F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2021 to 2026.

Timing deviation after other repairs, intake bank 1 TAIGO_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1

  • Service 22DID 4181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2021 to 2026.

Timing deviation current value exhaust bank 1 TAIGO_TIM_DEV_CURRENT_EXH_1

  • Service 22DID 4185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2021 to 2026.

Timing deviation current value intake bank 1 TAIGO_TIM_DEV_CURRENT_INT_1

  • Service 22DID 4183
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2021 to 2026.

Torque converter: torque loss TAIGO_TORQUE_CONVERTER_TORQUE_LOSS_7E1

  • Service 22DID 7053
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque factor TAIGO_TQ_FACTOR

  • Service 22DID 2119
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Torque increase request from ESP TAIGO_TQ_INCREASE_REQ_ESP

  • Service 22DID 1340
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque limit TAIGO_PQ35_LIM_TRQ

  • Service 22DID 106B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque limitation TAIGO_TORQUE_LIMITATION_7E1

  • Service 22DID 203F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque limitation TAIGO_TQ_LIM

  • Service 22DID 107D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque limitation TAIGO_TQ_LIM_7E0

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque limitation, clutch protection TAIGO_TQ_LIM_CLU

  • Service 22DID 20A0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque loss adaptation TAIGO_TQ_LOSS_ADPT

  • Service 22DID 2122
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque loss adaptation at idle TAIGO_TQ_LOSS_ADPT_IDLE

  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque loss adaptation, A/C compressor TAIGO_TQ_LOSS_ADPT_AC_COMP_7E0

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque reduction due to exhaust temperature TAIGO_PQ35_TRQ_RED_EXH_T

  • Service 22DID 10E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
-3.2768 to 3.2767
Unit
Number

In testing for 2021 to 2026.

Torque reduction request from ESP TAIGO_TQ_REDUCTION_REQ_ESP

  • Service 22DID 133F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque request, sum of auxiliary aggregate TAIGO_TQ_REQ_SUM_AUXILIARY

  • Service 22DID 209B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque transmitting function, ratio TAIGO_TQ_TRANSMITTING

  • Service 22DID 2105
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2021 to 2026.

Total mass of gasoline and ethyl alcohol in oil TAIGO_TOT_MASS_GASOLINE

  • Service 22DID 1713
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.021333
Range
0 to 1398
Unit
Raw value

In testing for 2021 to 2026.

Transmission drag torque TAIGO_TCM_DRAG_TQ

  • Service 22DID 1021
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2021 to 2026.

Transmission fluid temperature, calculated TAIGO_ATF_T_CALCULATED_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 704E
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2021 to 2026.

Transmission fluid temperature, dual-clutch TAIGO_ATF_T_DUAL_CLU

  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

Transmission fluid temperature, modeled maximum reached TAIGO_ATF_T_MODELED_MAX_REACHED_7E1

  • Service 22DID 7051
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

In testing for 2021 to 2026.

Transmission torque losses TAIGO_TCM_TQ_LOSSES

  • Service 22DID 1022
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2021 to 2026.

Turbine actuator 1 bank 1 activation TAIGO_PQ35_TURB_ACT_1_B1

  • Service 22DID 117E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Turbine actuator 1 bank 1: activation TAIGO_ACT

  • Service 22DID 112C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2022.

Upper adapted coupling point K1 from macro slip path adaptation TAIGO_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPT

  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2021 to 2026.

Upper adapted coupling point K2 from macro slip path adaptation TAIGO_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPT

  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2021 to 2026.

Valve lift system, result of last switch, intake TAIGO_VLV_LIFT_SYSTEM

  • Service 22DID 16BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Valve lift system, valve lift, exhaust TAIGO_VLV_LIFT_SYSTEM_VLV_LIFT

  • Service 22DID 16BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Valve lift system, valve lift, intake TAIGO_VLV_LIFT_SYSTEM_VLV

  • Service 22DID 16BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Valve timing, the difference between the, actual and the set angle TAIGO_VLV_TIM_DIFF_ACT_SET

  • Service 22DID 10EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×156.2510000
Range
-512 to 511 °
Unit
°

In testing for 2021 to 2026.

Variable valve timing, intake, bank 1, switch on TAIGO_VARIABLE_VLV_TIM_INT_1

  • Service 22DID 127D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Wear index TAIGO_PQ35_WEAR_IDX

  • Service 22DID 10E2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 m
Unit
m

In testing for 2021 to 2026.

Wear index %, 0=new engine TAIGO_WEAR_INDEX_0_NEW_ENG

  • Service 22DID 20C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

AuxInputs

Auto Trans Neutral Drive Status N/D_STATSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Glow plug lamp status GPL_STATSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Manual Trans Neutral Gear Status N/G_STATSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Power Take Off (PTO) Output Status PTO_STAT_AUXSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Recommended gear GEAR_RCMDSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 11 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
No or yes

Confirmed for 2022.

AuxInputs › Internal

Auto trans neutral drive status supported N/D_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Glow plug lamp status supported GPL_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Manual trans neutral gear status supported N/G_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Power Take Off (PTO) output status supported PTO_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Recommended gear supported GEAR_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

DPF

Diesel particulate filter oil ash volume TAIGO_MIS_2_7E0Confirmed

  • Service 22DID 1153
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 L
Unit
L

0x0000 = 0 → 0100 = 0 L

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Distance since last regeneration TAIGO_PQ35_DIST_LAST_REGENConfirmed

  • Service 22DID 1156
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 km
Unit
km

0x0000 = 0 → 01000 = 0 km

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Regeneration duration TAIGO_PQ35_REGEN_DUR

  • Service 22DID 1347
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 min
Unit
min

In testing for 2021 to 2026.

Service regeneration status TAIGO_PQ35_SRV_REGEN_STAT

  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

EGR

Exhaust gas recirculation 2: filter press loss, modeled TAIGO_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_MODELED

  • Service 22DID 2AE1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−500
Range
-3776.8 to 2776.7
Unit
Raw value

In testing for 2021 to 2026.

Exhaust gas recirculation 2: filter press loss, simulated TAIGO_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_SIMULATED

  • Service 22DID 2AE2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−500
Range
-3776.8 to 2776.7
Unit
Raw value

In testing for 2021 to 2026.

High pressure exhaust gas recirculation closing, variant 1 TAIGO_PQ35_HIGH_P_EGR_CLOSING_VAR_1

  • Service 22DID F469
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

High pressure exhaust gas recirculation closing, variant 2 TAIGO_PQ35_HIGH_P_EGR_CLOSING_VAR_2

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Internal

Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022.

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2022.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2022.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022. Supported for 2023.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

Confirmed for 2022. Supported for 2023.

SHRTFT associated with O2S12 SHRTFT12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2022. Supported for 2023.

Fluids

Oil level, critical TAIGO_OIL_CRITConfirmed

  • Service 22DID 11BB
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

0x0175 = 373 → 3732500 = 0.1492 cm

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Oil level, maximum TAIGO_OIL_MAXConfirmed

  • Service 22DID 11C4
  • Module7E0
  • Every30 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 cm
Unit
cm

0x8000 = 32768 → 32768250 = 131.072 cm

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Oil level, minimum TAIGO_OIL_MINConfirmed

  • Service 22DID 11C5
  • Module7E0
  • Every30 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262 cm
Unit
cm

0x8000 = 32768 → 32768250 = 131.072 cm

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Fuel

Activation of fuel pump electronics TAIGO_ACTIVATION_FUEL_PMP

  • Service 22DID 2028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Counter of fuel entry in oil TAIGO_CNT_FUEL_ENTRY_OIL

  • Service 22DID 399F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Error counter bad fuel TAIGO_ERROR_CNT_BAD_FUEL

  • Service 22DID 44BB
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2021 to 2026.

Fuel consumption - actual drive cycle TAIGO_FUEL_CONS_ACT_DRIVE

  • Service 22DID 1519
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2021 to 2026.

Fuel consumption per driving cycle TAIGO_FUEL_CONS_PER

  • Service 22DID 51D6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2021 to 2026.

Fuel filter: water level sensor 1 TAIGO_MQB_FUEL_FILTER_WATER_LEVEL_SENSOR_1

  • Service 22DID 197C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Fuel flow TAIGO_FUEL_FLOW

  • Service 22DID 10A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 L
Unit
L

In testing for 2021 to 2026.

Fuel flow rate TAIGO_PQ35_FUEL_FLOW

  • Service 22DID 111A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 L
Unit
L

In testing for 2021 to 2026.

Fuel high pressure, actual value TAIGO_FUEL_HIGH_P_ACT

  • Service 22DID 2027
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2021 to 2026.

Fuel high pressure, control deviation TAIGO_FUEL_HIGH_P_CTRL_DEV

  • Service 22DID 20BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 bar
Unit
bar

In testing for 2021 to 2026.

Fuel high pressure, specified value TAIGO_FUEL_HIGH_P_SPEC

  • Service 22DID 293B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2021 to 2026.

Fuel injector time deviation, cylinder 1 TAIGO_FUEL_INJ_TIME_DEV_1

  • Service 22DID 2000
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2021 to 2026.

Fuel injector time deviation, cylinder 2 TAIGO_FUEL_INJ_TIME_DEV_2

  • Service 22DID 207B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2021 to 2026.

Fuel injector time deviation, cylinder 2 TAIGO_FUEL_INJ_TIME_DEV_CYL_2

  • Service 22DID 21C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2021 to 2026.

Fuel injector time deviation, cylinder 3 TAIGO_FUEL_INJ_TIME_DEV_3

  • Service 22DID 2100
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2021 to 2026.

Fuel injector time deviation, cylinder 4 TAIGO_FUEL_INJ_TIME_DEV_4

  • Service 22DID 2101
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2021 to 2026.

Fuel level TAIGO_FLI_7E0

  • Service 22DID 1008
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2021 to 2026.

Fuel level TAIGO_PQ35_FUEL_LEVEL_7E0_2206

  • Service 22DID 2206
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2021 to 2026.

Fuel level input % TAIGO_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Fuel level input, v1 TAIGO_FUEL_LEVEL_INPUT_V1

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 14B4
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2021 to 2026.

Fuel level input, variant 2 TAIGO_FLI_INPUT_VAR_2

  • Service 22DID 24FC
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2021 to 2026.

Fuel level variant TAIGO_PQ35_FUEL_LVL_2

  • Service 22DID 100C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2021 to 2026.

Fuel low pressure, actual value TAIGO_FUEL_LOW_P_ACT

  • Service 22DID 2025
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2021 to 2026.

Fuel low pressure, specified value TAIGO_FUEL_LOW_P_SPEC

  • Service 22DID 2932
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2021 to 2026.

Fuel mass request, integral controller TAIGO_FUEL_MASS_REQ_I_CTL

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10597500000
Range
-694 to 694
Unit
Raw value

In testing for 2021 to 2026.

Fuel mass request, proportional controller TAIGO_FUEL_MASS_REQ_P_CTL

  • Service 22DID 1312
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10597500000
Range
-694 to 694
Unit
Raw value

In testing for 2021 to 2026.

Fuel metering valve TAIGO_FUEL_METERING_VLV

  • Service 22DID 209A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Fuel mix correction coefficient TAIGO_FUEL_MIX_CORR

  • Service 22DID 1710
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518−273.1
Range
-273.1 to -73.1003
Unit
Number

In testing for 2021 to 2026.

Fuel part from EVAP system TAIGO_FUEL_PART_EVAP

  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×781100000
Range
-0.9996 to 0.9918
Unit
Number

In testing for 2021 to 2026.

Fuel pressure regulator position TAIGO_PQ35_FUEL_P_REG

  • Service 22DID 11BF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Fuel pressure regulator valve: specified value rail pressure TAIGO_SPEC_VALUE_RAIL_P

  • Service 22DID 121E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2021 to 2026.

Fuel pressure, low actual TAIGO_FUEL_P_LOW_ACT

  • Service 22DID 1AB8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2021 to 2026.

Fuel pump adaptation TAIGO_FUEL_PMP_ADPT

  • Service 22DID 11C9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2021 to 2026.

Fuel pump specified value TAIGO_FUEL_PMP_SPEC

  • Service 22DID 1109
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Fuel pump, commanded duty TAIGO_FUEL_PMP_CMD_DUTY

  • Service 22DID 11A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0015258743
Range
0 to 99.99 %
Unit
%

In testing for 2021 to 2026.

Fuel rate TAIGO_FUEL_RATE

  • Service 22DID 113F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L/h
Unit
L/h

In testing for 2021 to 2026.

Fuel rate difference, injector/sensor TAIGO_FUEL_RATE_DIFF_INJ

  • Service 22DID 180A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×195315000000
Range
-127.9983 to 127.9944 L
Unit
L

In testing for 2021 to 2026.

Fuel rate, variant 2 TAIGO_FUEL_RATE_VAR_2

  • Service 22DID 204C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2021 to 2026.

Fuel temperature TAIGO_FUEL_T

  • Service 22DID 128A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2021 to 2026.

Fuel temperature TAIGO_FUEL_T_7E0

  • Service 22DID 203E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2021 to 2026.

Fuel temperature TAIGO_FUEL_T_7E0_2

  • Service 22DID 111C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2021 to 2026.

High fuel pressure control deviation TAIGO_HIGH_FUEL_P_CONTROL_DEVIATION

  • Service 22DID 121F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2021 to 2026.

High fuel pressure, actual TAIGO_HIGH_FUEL_P_ACT

  • Service 22DID 159F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2021 to 2026.

High fuel pressure, actual value TAIGO_HIGH_FUEL_P_ACT_7E0

  • Service 22DID 4460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2021 to 2026.

High fuel pressure, commanded TAIGO_HIGH_FUEL_P_CMD

  • Service 22DID 11D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2021 to 2026.

High fuel pressure, regulation error TAIGO_HIGH_FUEL_P

  • Service 22DID 11D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2021 to 2026.

High fuel pressure, target TAIGO_HIGH_FUEL_P_TGT

  • Service 22DID 111B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.76
Unit
Raw value

In testing for 2021 to 2026.

High pressure fuel pressure actual TAIGO_PQ35_FUEL_P_HIGH

  • Service 22DID 1169
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2021 to 2026.

High pressure fuel pressure commanded TAIGO_PQ35_FUEL_P_HIGH_CMD

  • Service 22DID 116A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2021 to 2026.

Long term fuel trim at idle TAIGO_LONG_TERM_FUEL_TRIM_7E0

  • Service 22DID 110E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 %
Unit
%

In testing for 2021 to 2026.

Long term fuel trim at idle TAIGO_LONG_TERM_FUEL_TRIM_IDLE_7E0

  • Service 22DID 4381
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2021 to 2026.

Long term fuel trim bank 1 TAIGO_LONG_TERM_FUEL_TRIM_1

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2021 to 2026.

Long term fuel trim direct injection at load TAIGO_LONG_TERM_FUEL_TRIM

  • Service 22DID 1779
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2021 to 2026.

Long term fuel trim port injection at load TAIGO_LONG_TERM_FUEL_TRIM_PORT

  • Service 22DID 177B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2021 to 2026.

Low fuel pressure, actual TAIGO_LOW_FUEL_P_ACT

  • Service 22DID 11C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2021 to 2026.

Low fuel pressure, commanded TAIGO_LOW_FUEL_P_CMD

  • Service 22DID 11CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2021 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual TAIGO_RAT_EVAPORATED_FUEL_ACT

  • Service 22DID 1711
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×781100000
Range
0 to 1.9915
Unit
Number

In testing for 2021 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum TAIGO_RAT_EVAPORATED_FUEL_MAX

  • Service 22DID 1712
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×8310625
Range
0 to 1.992
Unit
Number

In testing for 2021 to 2026.

Short term fuel trim bank 1 TAIGO_SHORT_TERM_FUEL_TRIM_1

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2021 to 2026.

GPS

Satellites, tracked TAIGO_GPS_SATS_TRACKED

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Satellites, visible TAIGO_GPS_SATS_VISIBLE

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Movement

Acceleration TAIGO_ACCEL

  • Service 22DID 2116
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 m/s²
Unit
m/s²

In testing for 2021 to 2026.

Acceleration TAIGO_ACCEL_7E0

  • Service 22DID 10CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 m/s²
Unit
m/s²

In testing for 2021 to 2026.

Acceleration TAIGO_ACCELERATION

  • Service 22DID 1187
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2021 to 2026.

Acceleration TAIGO_ACCELERATION_29BIT_7E0

  • Service 22DID 12B0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2021 to 2026.

Acceleration or deceleration mode TAIGO_ACCEL_DECCELERATION

  • Service 22DID 2118
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Accelerator pedal limit TAIGO_PQ35_LIM_ACCEL_PED

  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Accelerator pedal position TAIGO_ACCEL_PEDAL_POS

  • Service 22DID 3804
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Accelerator pedal position TAIGO_ACCEL_PEDAL_POS_7E1

  • Service 22DID F449
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Accelerator pedal sensor 1 TAIGO_PQ35_ACCEL_PED_1

  • Service 22DID 1221
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2021 to 2026.

Accelerator pedal sensor 2 TAIGO_PQ35_ACCEL_PED_2

  • Service 22DID 102E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2021 to 2026.

Accelerator pedal torque limit TAIGO_ACCEL_PEDAL_TQ_LIM

  • Service 22DID 1059
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Accelerator position 1 TAIGO_ACCEL_POS_1

  • Service 22DID F449
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Accelerator position 2 TAIGO_ACCEL_POS_2

  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Aux. hydraulic pump RPM TAIGO_AUX_HYDRAULIC_PMP_RPM

  • Service 22DID 70D6
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2021 to 2026.

Camshaft speed TAIGO_CAM_SPD

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2021 to 2026.

Camshaft speed TAIGO_CAM_SPD_7E0

  • Service 22DID 1092
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2021 to 2026.

Camshaft speed TAIGO_PQ35_CAMS_SPD

  • Service 22DID 133B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.3
Range
-9830.4 to 9830.1 rpm
Unit
rpm

In testing for 2021 to 2026.

Compressor speed TAIGO_COMP_SPD

  • Service 22DID 46E1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2021 to 2026.

Crankshaft speed, RPM TAIGO_CRANK_SPD_RPM

  • Service 22DID 206E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2021 to 2026.

Engine RPM TAIGO_RPM

  • Service 22DID 16F3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

In testing for 2021 to 2026.

Engine RPM TAIGO_RPM_7E0

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 7000 rpm
Unit
rpm

In testing for 2021 to 2026.

Engine RPM at idle required TAIGO_ENGINE_RPM_AT_IDLE_REQUIRED_7E0

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2021 to 2026.

Front left wheel speed TAIGO_TIRE_FL_SPD

  • Service 22DID 2B1B
  • Module7E1
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2021, 2023 to 2026. Not supported for 2022.

Front right wheel speed TAIGO_TIRE_FR_SPD

  • Service 22DID 2B1C
  • Module7E1
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2021, 2023 to 2026. Not supported for 2022.

Front right wheel speed TAIGO_TIRE_FR_SPD_V3

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2021, 2023 to 2026. Not supported for 2022.

Idle speed specified rpm TAIGO_IDLE_SPD_SPEC_RPM

  • Service 22DID 4056
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2021 to 2026.

Injection speed injector 0 TAIGO_INJ_SPD_INJ_0

  • Service 22DID 10A4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2021 to 2026.

Injection speed injector 1 TAIGO_INJ_SPD_INJ_1

  • Service 22DID 10A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2021 to 2026.

Injection speed injector 2 TAIGO_INJ_SPD_INJ_2

  • Service 22DID 10A6
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2021 to 2026.

Injection speed injector 3 TAIGO_INJ_SPD_INJ_3

  • Service 22DID 10A8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2021 to 2026.

Input shaft speed 1 TAIGO_INPUT_SHFT_SPD_1

  • Service 22DID 70E0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 7000 rpm
Unit
rpm

In testing for 2021 to 2026.

Input shaft speed 2 TAIGO_INPUT_SHFT_SPD_2

  • Service 22DID 70E1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 7000 rpm
Unit
rpm

In testing for 2021 to 2026.

Lateral acceleration TAIGO_LATERAL_ACCEL

  • Service 22DID 1644
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 m/s²
Unit
m/s²

In testing for 2021 to 2026.

Lateral acceleration, raw value TAIGO_LATERAL_ACCEL_RAW

  • Service 22DID 15D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 m/s²
Unit
m/s²

In testing for 2021 to 2026.

Longitudinal acceleration TAIGO_LONGITUDINAL_ACCEL_7E0

  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2021 to 2026.

Longitudinal acceleration, raw value TAIGO_LONGITUDINAL_ACCEL

  • Service 22DID 15CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2021 to 2026.

Misfires per 1000 rpm, all cylinders TAIGO_MIS_PER_1000_RPM_ALL

  • Service 22DID 148B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires per 1000 rpm:, cylinder 3 TAIGO_MIS_PER_1000_RPM_3

  • Service 22DID 1486
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires per 1000 rpm:, cylinder 5 TAIGO_MIS_PER_1000_RPM_5

  • Service 22DID 1489
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires/1000 rpm, cylinder 1 TAIGO_MISFIRES_1000_RPM_C1_7E0

  • Service 22DID 291D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires/1000 rpm, cylinder 2 TAIGO_MISFIRES_1000_RPM_C2_7E0

  • Service 22DID 2920
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires/1000 rpm, cylinder 3 TAIGO_MISFIRES_1000_RPM_C3_7E0

  • Service 22DID 291E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires/1000 rpm, cylinder 4 TAIGO_MISFIRES_1000_RPM_C4_7E0

  • Service 22DID 291F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Mixture adaptation factor at idle speed TAIGO_MIXTURE_ADPT_FACTOR_IDLE

  • Service 22DID 3997
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2021 to 2026.

Rear left wheel speed TAIGO_TIRE_RL_SPD

  • Service 22DID 2B1D
  • Module7E1
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2021, 2023 to 2026. Not supported for 2022.

Rear right wheel speed TAIGO_TIRE_RR_SPD

  • Service 22DID 2B1E
  • Module7E1
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2021, 2023 to 2026. Not supported for 2022.

Reducing agent pump, differential speed calculated TAIGO_REDUCING_AGENT_PMP

  • Service 22DID 18CC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2021 to 2026.

Specified idle RPM TAIGO_MQB_DQ250_SPECIFIED_IDLE_RPM

  • Service 22DID 3871
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

In testing for 2021 to 2026.

Speed ​​output TAIGO_MQB_DQ250_SPD_OUTPUT

  • Service 22DID 1009
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

In testing for 2021 to 2026.

Transmission input shaft speed TAIGO_PQ35_TRANS_IN_SPD

  • Service 22DID 11F1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2021 to 2026.

Transmission input speed TAIGO_MQB_TCM_TRANSMISSION_INPUT_SPD_7E1_380A

  • Service 22DID 380A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2021 to 2026.

Transmission output speed TAIGO_MQB_TCM_TRANSMISSION_OUTPUT_SPD_7E1_380B

  • Service 22DID 380B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2021 to 2026.

Vehicle speed TAIGO_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Vehicle speed TAIGO_VSS_7E1

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2021 to 2026.

Vehicle speed ESP TAIGO_VSS_ESP

  • Service 22DID 1005
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2021 to 2026.

Vehicle speed from transmission TAIGO_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSION

  • Service 22DID 100A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 km/h
Unit
km/h

In testing for 2021 to 2026.

Vehicle speed, HR TAIGO_VSS_HR

  • Service 22DID 2106
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2021 to 2026.

Yaw acceleration, raw value TAIGO_YAW_ACCEL_RAW

  • Service 22DID 15D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2021 to 2026.

Stats

Driving time, eco TAIGO_DRIVE_TIME_ECO

Value may be wrong, needs more validation. Proportion of time spent driving in eco mode

  • Service 22DID 0303
  • Module7E1
  • Every900 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2021, 2023 to 2026. Not supported for 2022.

Driving time, manual TAIGO_DRIVE_TIME_MANUAL

Value may be wrong, needs more validation. Proportion of time spent driving in manual mode

  • Service 22DID 0305
  • Module7E1
  • Every900 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2021, 2023 to 2026. Not supported for 2022.

Driving time, sport TAIGO_DRIVE_TIME_SPORT

Value may be wrong, needs more validation. Proportion of time spent driving in sport mode

  • Service 22DID 0304
  • Module7E1
  • Every900 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2021, 2023 to 2026. Not supported for 2022.

Total drive time TAIGO_DRIVE_TIME

  • Service 22DID 0302
  • Module7E1
  • Every900 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 h
Unit
h

In testing for 2021, 2023 to 2026. Not supported for 2022.

TAIGO_PQ35_TIME_LAST

Time since last regeneration TAIGO_PQ35_TIME_LAST_REGEN

  • Service 22DID 115E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10066666667
Range
0 to 0.426 min
Unit
min

In testing for 2021 to 2026.

Transmission

Actual position clutch 1 duty cycle factor 1 TAIGO_MQB_DQ200_ACTUAL_POS_CLUTCH_1_DUTY_CYCLE_FACTOR_1

  • Service 22DID 3832
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Actual position clutch 1 duty cycle factor 2 TAIGO_MQB_DQ200_ACTUAL_POS_CLUTCH_1_DUTY_CYCLE_FACTOR_2

  • Service 22DID 3833
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Actual position clutch 2 duty cycle factor 1 TAIGO_MQB_DQ200_ACTUAL_POS_CLUTCH_2_DUTY_CYCLE_FACTOR_1

  • Service 22DID 383B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Actual position clutch 2 duty cycle factor 2 TAIGO_MQB_DQ200_ACTUAL_POS_CLUTCH_2_DUTY_CYCLE_FACTOR_2

  • Service 22DID 383C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Actual position of gear actuator a TAIGO_MQB_DQ250_ACUTAL_POS_GEAR_POSER_A

  • Service 22DID 3852
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Actual position of gear actuator b TAIGO_MQB_DQ250_ACUTAL_POS_GEAR_POSER_B

  • Service 22DID 385A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Actual position of gear actuator c TAIGO_MQB_DQ250_ACUTAL_POS_GEAR_POSER_C

  • Service 22DID 3862
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Actual position of gear actuator d TAIGO_MQB_DQ250_ACUTAL_POS_GEAR_POSER_D

  • Service 22DID 386A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Adaptation counter PF lockup clutch TAIGO_ADPT_CNT_PF_LOCKUP

  • Service 22DID 1103
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Adaptation counter, clutch a TAIGO_ADPT_CNT_CLU

  • Service 22DID 7085
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Adaptation counter, clutch b TAIGO_ADPT_CNT_CLU_B

  • Service 22DID 7089
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Adaptation counter, clutch c TAIGO_ADPT_CNT_CLU_C

  • Service 22DID 708D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Adaptation counter, clutch d TAIGO_ADPT_CNT_CLU_D

  • Service 22DID 7091
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Adaptation counter, clutch e TAIGO_ADPT_CNT_CLU_E

  • Service 22DID 7095
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Adaptation counter, fast fill time, clutch a TAIGO_ADPT_CNT_FAST_FILL

  • Service 22DID 7087
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Adaptation counter, fast fill time, clutch b TAIGO_ADPT_CNT_FAST_FILL_B

  • Service 22DID 708B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Adaptation counter, fast fill time, clutch c TAIGO_ADPT_CNT_FAST_FILL_C

  • Service 22DID 708F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Adaptation counter, fast fill time, clutch d TAIGO_ADPT_CNT_FAST_FILL_D

  • Service 22DID 7093
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Adaptation counter, fast fill time, clutch e TAIGO_ADPT_CNT_FAST_FILL_E

  • Service 22DID 7097
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Adaptation counter, torque converter lockup clutch TAIGO_ADPT_CNT_TSF_LOCKUP

  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Adaptation fill time, torque converter lockup clutch TAIGO_ADPT_INFLATION_TIME

  • Service 22DID 1100
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 ms
Unit
ms

In testing for 2021 to 2026.

Adaptation inflation current PF lockup clutch TAIGO_ADPT_INFLATION

  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 2021 to 2026.

Automatic transmission input speed TAIGO_AT_INPUT_SPEED

  • Service 22DID 2102
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2021 to 2026.

Automatic transmission output speed TAIGO_AT_OUTPUT_SPEED

  • Service 22DID 2103
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2021 to 2026.

Clutch 0 commanded pressure offset TAIGO_MQB_DL382_CLUTCH_0_CMD_P_OFFSET

  • Service 22DID 1426
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 absolute pressure TAIGO_MQB_DL382_CLUTCH_1_ABSOLUTE_P

  • Service 22DID 13CC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 actual pressure TAIGO_PQ35_CLUTCH_1_ACTUAL_P

  • Service 22DID 38EB
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 actual pressure raw value TAIGO_PQ35_DL382_CLUTCH_1_ACTUAL_P_RAW_VALUE

  • Service 22DID 10F9
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 adaptation basic characteristic point 0 moment TAIGO_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_0_MOMENT

  • Service 22DID 1058
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Clutch 1 adaptation basic characteristic point 0 position TAIGO_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_0_POS

  • Service 22DID 1057
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 adaptation basic characteristic point 1 moment TAIGO_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_1_MOMENT

  • Service 22DID 105A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Clutch 1 adaptation basic characteristic point 1 position TAIGO_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_1_POS

  • Service 22DID 1059
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 adaptation basic characteristic point 2 moment TAIGO_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_2_MOMENT

  • Service 22DID 105C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Clutch 1 adaptation basic characteristic point 2 position TAIGO_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_2_POS

  • Service 22DID 105B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 adaptation basic characteristic point 3 moment TAIGO_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_3_MOMENT

  • Service 22DID 105E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Clutch 1 adaptation basic characteristic point 3 position TAIGO_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_3_POS

  • Service 22DID 105D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 adaptation basic characteristics point 0 position TAIGO_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_0_POS

  • Service 22DID 38AE
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 1 adaptation basic characteristics point 1 position TAIGO_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_1_POS

  • Service 22DID 38AF
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 1 adaptation basic characteristics point 2 position TAIGO_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_2_POS

  • Service 22DID 7000
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 1 adaptation basic characteristics point 3 position TAIGO_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_3_POS

  • Service 22DID 7001
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 1 adaptation clutch end position closed TAIGO_MQB_DQ200_CLUTCH_1_ADAPT_CLUTCH_END_POS_CLOSED

  • Service 22DID 38FF
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 1 adaptation clutch end position open TAIGO_MQB_DQ200_CLUTCH_1_ADAPT_CLUTCH_END_POS_OPEN

  • Service 22DID 38FE
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 1 characteristic curve shift TAIGO_PQ35_CLUTCH_1_CHAR_CURVE_SHIFT

  • Service 22DID 1063
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.11 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 1 commanded pressure TAIGO_PQ35_CLUTCH_1_CMD_P

  • Service 22DID 38EC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 failed adaptations counter TAIGO_PQ35_CLUTCH_1_FAILED_ADAPTS_COUNTER

  • Service 22DID 10CC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Clutch 1 friction value correction factor TAIGO_PQ35_CLUTCH_1_FRICTION_VALUE_CORRECTION_FACTOR

  • Service 22DID 1062
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.09766
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Clutch 1 lower adaptation point TAIGO_CLU_1_LO_ADPT_POINT

  • Service 22DID 1120
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 nominal pressure TAIGO_CLU_1_NOMINAL_P

  • Service 22DID 125C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 pressure TAIGO_MQB_DL382_CLUTCH_1_P

  • Service 22DID 214C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 protection function engaged quantity TAIGO_PQ35_CLUTCH_1_PROT_ENGAGED_QTY

  • Service 22DID 1069
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2021 to 2026.

Clutch 1 successful adaptations counter TAIGO_PQ35_CLUTCH_1_SUCCESSFUL_ADAPTS_COUNTER

  • Service 22DID 10C9
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Clutch 1 upper adaptation point TAIGO_CLU_1_HI_ADPT_POINT

  • Service 22DID 1124
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 1 valve current: actual TAIGO_MQB_DQ250_CLUTCH_1_VALVE_I_ACTUAL

  • Service 22DID 3835
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

In testing for 2021 to 2026.

Clutch 1 valve current: specified TAIGO_MQB_DQ250_CLUTCH_1_VALVE_I_SPECIFIED

  • Service 22DID 3834
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

In testing for 2021 to 2026.

Clutch 2 absolute pressure TAIGO_MQB_DL382_CLUTCH_2_ABSOLUTE_P

  • Service 22DID 13CD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 actual pressure TAIGO_PQ35_CLUTCH_2_ACTUAL_P

  • Service 22DID 38EA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 actual pressure raw value TAIGO_PQ35_DL382_CLUTCH_2_ACTUAL_P_RAW_VALUE

  • Service 22DID 10FA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 actual torque TAIGO_MQB_TCM_CLUTCH_2_ACTUAL_TORQUE

  • Service 22DID 3839
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Clutch 2 adaptation basic characteristic point 0 moment TAIGO_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_0_MOMENT

  • Service 22DID 106D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Clutch 2 adaptation basic characteristic point 0 position TAIGO_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_0_POS

  • Service 22DID 106C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 adaptation basic characteristic point 1 moment TAIGO_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_1_MOMENT

  • Service 22DID 106F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Clutch 2 adaptation basic characteristic point 1 position TAIGO_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_1_POS

  • Service 22DID 106E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 adaptation basic characteristic point 2 moment TAIGO_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_2_MOMENT

  • Service 22DID 1071
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Clutch 2 adaptation basic characteristic point 2 position TAIGO_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_2_POS

  • Service 22DID 1070
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 adaptation basic characteristic point 3 moment TAIGO_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_3_MOMENT

  • Service 22DID 1073
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Clutch 2 adaptation basic characteristic point 3 position TAIGO_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_3_POS

  • Service 22DID 1072
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 adaptation basic characteristics point 0 position TAIGO_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_0_POS

  • Service 22DID 38FA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 2 adaptation basic characteristics point 1 position TAIGO_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_1_POS

  • Service 22DID 38FB
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 2 adaptation basic characteristics point 2 position TAIGO_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_2_POS

  • Service 22DID 38FC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 2 adaptation basic characteristics point 3 position TAIGO_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_3_POS

  • Service 22DID 38FD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 2 adaptation clutch end position closed TAIGO_MQB_DQ200_CLUTCH_2_ADAPT_CLUTCH_END_POS_CLOSED

  • Service 22DID 38AB
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 2 adaptation clutch end position open TAIGO_MQB_DQ200_CLUTCH_2_ADAPT_CLUTCH_END_POS_OPEN

  • Service 22DID 38AA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 2 adaptation end position closed TAIGO_PQ35_CLUTCH_2_ADAPT_END_POS_CLOSED

  • Service 22DID 1075
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 adaptation end position opened TAIGO_PQ35_CLUTCH_2_ADAPT_END_POS_OPENED

  • Service 22DID 1074
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 characteristic curve shift TAIGO_PQ35_CLUTCH_2_CHAR_CURVE_SHIFT

  • Service 22DID 1078
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×9.810000
Range
-32.11 to 32.11 mm
Unit
mm

In testing for 2021 to 2026.

Clutch 2 commanded pressure TAIGO_PQ35_CLUTCH_2_CMD_P

  • Service 22DID 38ED
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 failed adaptations counter TAIGO_PQ35_CLUTCH_2_FAILED_ADAPTS_COUNTER

  • Service 22DID 10ED
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Clutch 2 friction value correction factor TAIGO_MQB_DQ200_CLUTCH_2_FRICTION_VALUE_CORRECTION_FACTOR

  • Service 22DID 1077
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.09766
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Clutch 2 lower adaptation point TAIGO_CLU_2_LO_ADPT_POINT

  • Service 22DID 1121
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 pressure TAIGO_MQB_DL382_CLUTCH_2_P

  • Service 22DID 214D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 protection function engaged quantity TAIGO_PQ35_CLUTCH_2_PROT_ENGAGED_QTY

  • Service 22DID 107E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2021 to 2026.

Clutch 2 successful adaptations counter TAIGO_PQ35_CLUTCH_2_SUCCESSFUL_ADAPTS_COUNTER

  • Service 22DID 10EA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Clutch 2 upper adaptation point TAIGO_CLU_2_HI_ADPT_POINT

  • Service 22DID 1125
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2021 to 2026.

Clutch 2 valve current: actual TAIGO_MQB_DQ250_CLUTCH_2_VALVE_I_ACTUAL

  • Service 22DID 383E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

In testing for 2021 to 2026.

Clutch 2 valve current: specified TAIGO_MQB_DQ250_CLUTCH_2_VALVE_I_SPECIFIED

  • Service 22DID 383D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

In testing for 2021 to 2026.

Clutch adaptation values initial kill point 0 for K1 TAIGO_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K1

  • Service 22DID 1156
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2021 to 2026.

Clutch adaptation values initial kill point 0 for K2 TAIGO_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K2

  • Service 22DID 1157
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2021 to 2026.

Clutch adaptation values lower current point adaptation K1 TAIGO_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K1

  • Service 22DID 1158
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2021 to 2026.

Clutch adaptation values lower current point adaptation K2 TAIGO_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K2

  • Service 22DID 1159
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2021 to 2026.

Clutch kiss point rapid adaptation remaining TAIGO_PQ35_CLUTCH_KISSPOINT_RAPID_ADAPT_REMAINING

  • Service 22DID 1711
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2021 to 2026.

Clutch overheating, clutch TAIGO_CLU_OVERHEATING_CLU

  • Service 22DID 17FD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Clutch temperature TAIGO_CLU_T

  • Service 22DID 1259
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

Correction values for main press adaptation: high press on clutch 1 TAIGO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_1

  • Service 22DID 1181
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Correction values for main press adaptation: low press on clutch 1 TAIGO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_1

  • Service 22DID 1180
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Correction values for main pressure adaptation high pressure on clutch 2 TAIGO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_2

  • Service 22DID 1183
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Correction values for main pressure adaptation low pressure on clutch 2 TAIGO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_2

  • Service 22DID 1182
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2021 to 2026.

Current gear TAIGO_CURRENT_GEAR

  • Service 22DID 3EDE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2021 to 2026.

Current gear TAIGO_MQB_TCM_I_GEAR_DQ200

  • Service 22DID 3816
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−1
Range
-1 to 254
Unit
Number

In testing for 2021 to 2026.

Current gear TAIGO_PQ35_GEAR

  • Service 22DID 100D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2021 to 2026.

Current lower pressure point clutch 1 from current to pressure adaptation TAIGO_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT

  • Service 22DID 1130
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2021 to 2026.

Current lower pressure point clutch 2 from current to pressure adaptation TAIGO_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT

  • Service 22DID 1132
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2021 to 2026.

Current N371 pressure control valve 6 lock-up clutch TAIGO_CURRENT_N371_P_CTRL_6

  • Service 22DID 1029
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mA
Unit
mA

In testing for 2021 to 2026.

Current upper pressure point clutch 1 from current to pressure adaptation TAIGO_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT

  • Service 22DID 1131
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2021 to 2026.

Current upper pressure point clutch 2 from current to pressure adaptation TAIGO_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT

  • Service 22DID 1133
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

In testing for 2021 to 2026.

Driving strategy mountain factor TAIGO_PQ35_DRIVING_STRATEGY_MOUNTAIN_FACTOR

  • Service 22DID 1018
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Driving strategy sport factor TAIGO_PQ35_DRIVING_STRATEGY_SPORT_FACTOR

  • Service 22DID 1019
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1700255
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Dynamic shift program TAIGO_DYNAMIC_SHIFT

  • Service 22DID 2115
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Early ignition counter for oxygen shift, cylinder 1 TAIGO_EARLY_IGN_CNT_OXYGEN_1

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter for oxygen shift, cylinder 2 TAIGO_EARLY_IGN_CNT_OXYGEN_2

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter for oxygen shift, cylinder 3 TAIGO_EARLY_IGN_CNT_OXYGEN_3

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Early ignition counter for oxygen shift, cylinder 4 TAIGO_EARLY_IGN_CNT_OXYGEN_4

  • Service 22DID 4E48
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Engaged position side a gear selector 1-3 TAIGO_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_1_3

  • Service 22DID 1138
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Engaged position side a gear selector 2-4 TAIGO_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_2_4

  • Service 22DID 1139
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Engaged position side a gear selector 5 and neutral TAIGO_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_5_N

  • Service 22DID 113A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Engaged position side a gear selector 6 and reverse TAIGO_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_6_R

  • Service 22DID 113B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Engaged position side b gear selector 1-3 TAIGO_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_1_3

  • Service 22DID 1144
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Engaged position side b gear selector 2-4 TAIGO_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_2_4

  • Service 22DID 1145
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Engaged position side b gear selector 5 and neutral TAIGO_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_5_N

  • Service 22DID 1146
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Engaged position side b gear selector 6 and reverse TAIGO_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_6_R

  • Service 22DID 1147
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Engine specified torque during transmission intervention TAIGO_ENG_SPEC_TQ_DURING

  • Service 22DID 2110
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2021 to 2026.

Fast fill time, clutch a TAIGO_FAST_FILL_TIME_CLU

  • Service 22DID 7086
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2021 to 2026.

Fast fill time, clutch b TAIGO_FAST_FILL_TIME_CLU_B

  • Service 22DID 708A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2021 to 2026.

Fast fill time, clutch c TAIGO_FAST_FILL_TIME_CLU_C

  • Service 22DID 708E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2021 to 2026.

Fast fill time, clutch d TAIGO_FAST_FILL_TIME_CLU_D

  • Service 22DID 7092
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2021 to 2026.

Fast fill time, clutch e TAIGO_FAST_FILL_TIME_CLU_E

  • Service 22DID 7096
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 ms
Unit
ms

In testing for 2021 to 2026.

Fill pressure, clutch a TAIGO_FILL_P_CLU

  • Service 22DID 7084
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2021 to 2026.

Fill pressure, clutch b TAIGO_FILL_P_CLU_B

  • Service 22DID 7088
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2021 to 2026.

Fill pressure, clutch c TAIGO_FILL_P_CLU_C

  • Service 22DID 708C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2021 to 2026.

Fill pressure, clutch d TAIGO_FILL_P_CLU_D

  • Service 22DID 7090
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2021 to 2026.

Fill pressure, clutch e TAIGO_FILL_P_CLU_E

  • Service 22DID 7094
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270
Unit
Raw value

In testing for 2021 to 2026.

Gear TAIGO_GEAR_V2

  • Service 22DID 14CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Gear actuator adaptation engaged position G1 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G1

  • Service 22DID 1082
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation engaged position G2 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G2

  • Service 22DID 1090
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation engaged position G3 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G3

  • Service 22DID 1086
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation engaged position G4 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G4

  • Service 22DID 1094
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation engaged position G5 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G5

  • Service 22DID 109E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation engaged position G6 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G6

  • Service 22DID 10AC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation engaged position G7 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G7

  • Service 22DID 10A2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation engaged position GR TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_GR

  • Service 22DID 10B0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation synchronization position G1 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G1

  • Service 22DID 1083
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation synchronization position G2 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G2

  • Service 22DID 1091
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation synchronization position G3 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G3

  • Service 22DID 1085
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation synchronization position G4 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G4

  • Service 22DID 1093
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation synchronization position G5 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G5

  • Service 22DID 109F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation synchronization position G6 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G6

  • Service 22DID 10AD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation synchronization position G7 TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G7

  • Service 22DID 10A1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear actuator adaptation synchronization position reverse TAIGO_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_GR

  • Service 22DID 10AF
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear selector a adaptation neutral position TAIGO_PQ35_GANGSTELLER_A_ADAPT_NEUTRALPOS

  • Service 22DID 1084
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear selector b adaptation neutral position TAIGO_PQ35_GANGSTELLER_B_ADAPT_NEUTRALPOS

  • Service 22DID 1092
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear selector c adaptation neutral position TAIGO_PQ35_GANGSTELLER_C_ADAPT_NEUTRALPOS

  • Service 22DID 10A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear selector d adaptation neutral position TAIGO_PQ35_GANGSTELLER_D_ADAPT_NEUTRALPOS

  • Service 22DID 10AE
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 mm
Unit
mm

In testing for 2021 to 2026.

Gear selector synchronous position g and reverse TAIGO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G_R

  • Service 22DID 117F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2021 to 2026.

Gear selector synchronous position G1 TAIGO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G1

  • Service 22DID 1179
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2021 to 2026.

Gear selector synchronous position G2 TAIGO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G2

  • Service 22DID 117A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2021 to 2026.

Gear selector synchronous position G3 TAIGO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G3

  • Service 22DID 117B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2021 to 2026.

Gear selector synchronous position G4 TAIGO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G4

  • Service 22DID 117C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2021 to 2026.

Gear selector synchronous position G5 TAIGO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G5

  • Service 22DID 117D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2021 to 2026.

Gear selector synchronous position G6 TAIGO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G6

  • Service 22DID 117E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

In testing for 2021 to 2026.

Input shaft 1 TAIGO_MQB_INPUT_SHAFT_1

  • Service 22DID 380C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2021 to 2026.

Input shaft 2 TAIGO_MQB_INPUT_SHAFT_2

  • Service 22DID 380D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2021 to 2026.

Launch control counter, clutch 1 TAIGO_LAUNCH_CTRL_CNT_CLU_1

  • Service 22DID 38C0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Load shift flaps, actual value TAIGO_LOAD_SHIFT_FLAPS_ACT

  • Service 22DID 295C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Load shift flaps, specified value TAIGO_LOAD_SHIFT_FLAPS_SPEC

  • Service 22DID 295D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Lower adapted coupling point clutch 1 from kiss point adaptation TAIGO_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_KISS_POINT_ADAPT

  • Service 22DID 388D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2021 to 2026.

Lower adapted coupling point clutch 2 from kiss point adaptation TAIGO_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_KISS_POINT_ADAPT

  • Service 22DID 388E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2021 to 2026.

Mileage of oxidation catalytic converter TAIGO_MILEAGE_OXIDATION

  • Service 22DID 51A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2021 to 2026.

Neutral position gear selector 1-3 TAIGO_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_1_3

  • Service 22DID 1140
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Neutral position gear selector 2-4 TAIGO_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_2_4

  • Service 22DID 1141
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Neutral position gear selector 5 and neutral TAIGO_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_5_N

  • Service 22DID 1142
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Neutral position gear selector 6 and reverse TAIGO_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_6_R

  • Service 22DID 1143
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Nominal pressure clutch 2 TAIGO_NOMINAL_P_CLU_2

  • Service 22DID 125D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 bar
Unit
bar

In testing for 2021 to 2026.

Output shaft 1 TAIGO_MQB_OUTPUT_SHAFT_1

  • Service 22DID 380E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2021 to 2026.

Output shaft 2 TAIGO_MQB_OUTPUT_SHAFT_2

  • Service 22DID 380F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2021 to 2026.

Powertrain overall gear ratio TAIGO_POWERTRAIN_OVERALL

  • Service 22DID 11DF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Number

In testing for 2021 to 2026.

Pressure_clutch_1 TAIGO_P_CLU_1

  • Service 22DID 1260
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2021 to 2026.

Pressure_clutch_2 TAIGO_P_CLU_2

  • Service 22DID 1261
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2021 to 2026.

Road resistance TAIGO_PQ35_ROAD_RESISTANCE

  • Service 22DID 1017
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24.9100−31.6
Range
-31 to 31.894 %
Unit
%

In testing for 2021 to 2026.

Selected gear TAIGO_PQ35_SELECTED_GEAR

  • Service 22DID 15AA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Selected gear TAIGO_SELECTED_GEAR_7E1

  • Service 22DID 7050
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253 °C
Unit
°C

In testing for 2021 to 2026.

Shift process, selected gear TAIGO_SHIFT_PROCCESS

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Shift process, target gear TAIGO_SHIFT_PROCCESS_TGT

  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Specified torque clutch 1 TAIGO_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_1

  • Service 22DID 382E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
0 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Specified torque clutch 1 - data TAIGO_SPEC_TQ_CLU_1_DATA

  • Service 22DID 2142
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2021 to 2026.

Specified torque clutch 2 TAIGO_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_2

  • Service 22DID 3838
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
-1638 to 1638.35 N·m
Unit
N·m

In testing for 2021 to 2026.

Specified torque clutch 2 - data TAIGO_SPEC_TQ_CLU_2_DATA

  • Service 22DID 2143
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2021 to 2026.

Stiffness point pressure clutch 1 TAIGO_MQB_DL382_STIFFNESS_POINT_P_CLUTCH_1

  • Service 22DID 1419
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 bar
Unit
bar

In testing for 2021 to 2026.

Stiffness point pressure clutch 2 TAIGO_MQB_DL382_STIFFNESS_POINT_P_CLUTCH_2

  • Service 22DID 141A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 bar
Unit
bar

In testing for 2021 to 2026.

Synchronous position side a gear selector 1-3 TAIGO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_1_3

  • Service 22DID 113C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Synchronous position side a gear selector 2-4 TAIGO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_2_4

  • Service 22DID 113D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Synchronous position side a gear selector 5 and neutral TAIGO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_5_N

  • Service 22DID 113E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Synchronous position side a gear selector 6 and reverse TAIGO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_6_R

  • Service 22DID 113F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Synchronous position side b gear selector 1-3 TAIGO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_1_3

  • Service 22DID 1148
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Synchronous position side b gear selector 2-4 TAIGO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_2_4

  • Service 22DID 1149
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Synchronous position side b gear selector 5 and neutral TAIGO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_5_N

  • Service 22DID 114A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Synchronous position side b gear selector 6 and reverse TAIGO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_6_R

  • Service 22DID 114B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Time since shift TAIGO_TIME_SINCE_SHIFT

  • Service 22DID 1033
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×30
Range
0 to 7650 ms
Unit
ms

In testing for 2021 to 2026.

Torque converter amplification TAIGO_TQ_CONV

  • Service 22DID 2130
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100
Range
0 to 2.55
Unit
Number

In testing for 2021 to 2026.

Torque converter lockup clutch status TAIGO_MQB_TCM_TORQUE_CONVERTER_LOCKUP_CLUTCH_STATUS

  • Service 22DID 7078
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Torque loss adaptation, A/C compressor + gear engaged TAIGO_TQ_LOSS_ADPT_AC_COMP

  • Service 22DID 1222
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Torque loss adaptation, gear engaged TAIGO_TQ_LOSS_ADPT_GEAR

  • Service 22DID 1224
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2021 to 2026.

Transmission coolant valve, open TAIGO_TRANS_CLT_VLV_OPEN

  • Service 22DID 3D74
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Transmission fluid temperature 2 TAIGO_ATF_T_2

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 38BF
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2021 to 2026.

Transmission gear ratio TAIGO_TRANS_GEAR_RAT

  • Service 22DID 0327
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val100
Range
-1.28 to 1.27
Unit
Number

In testing for 2021 to 2026.

Transmission part 1 pressure actual TAIGO_MQB_TCM_TRANSMISSION_PART_1_P_ACTUAL

  • Service 22DID 3821
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2021 to 2026.

Transmission part 1 pressure commanded TAIGO_MQB_TCM_TRANSMISSION_PART_1_P_CMD

  • Service 22DID 3820
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2021 to 2026.

Transmission part 1 valve current actual TAIGO_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_ACTUAL

  • Service 22DID 3827
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2021 to 2026.

Transmission part 1 valve current commanded TAIGO_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_CMD

  • Service 22DID 3826
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2021 to 2026.

Transmission part 2 pressure actual TAIGO_MQB_TCM_TRANSMISSION_PART_2_P_ACTUAL

  • Service 22DID 3824
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2021 to 2026.

Transmission part 2 pressure commanded TAIGO_MQB_TCM_TRANSMISSION_PART_2_P_CMD

  • Service 22DID 3823
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val100
Range
0 to 655.35 bar
Unit
bar

In testing for 2021 to 2026.

Transmission part 2 valve current actual TAIGO_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_ACTUAL

  • Service 22DID 382B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2021 to 2026.

Transmission part 2 valve current commanded TAIGO_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_CMD

  • Service 22DID 382A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

In testing for 2021 to 2026.

Upper adapted coupling point clutch 1 from micro-slip adaptation TAIGO_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_MICROSLIP_ADAPT

  • Service 22DID 388F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2021 to 2026.

Upper adapted coupling point clutch 2 from micro-slip adaptation TAIGO_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_MICROSLIP_ADAPT

  • Service 22DID 3890
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

In testing for 2021 to 2026.

Working hours TAIGO_PQ35_WORKING_HOURS

  • Service 22DID 1110
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×2360000
Range
0 to 23860.929
Unit
Raw value

In testing for 2021 to 2026.

Trips

Analysis, clutch 1 temperature time in range 1 TAIGO_ANALYSIS_CLU_1_T_1

  • Service 22DID 1066
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2021 to 2026.

Analysis, clutch 1 temperature time in range 2 TAIGO_ANALYSIS_CLU_1_T_2

  • Service 22DID 1067
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2021 to 2026.

Analysis, clutch 1 temperature time in range 3 TAIGO_ANALYSIS_CLU_1_T_3

  • Service 22DID 1068
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2021 to 2026.

Analysis, clutch 2 temperature time in range 0 TAIGO_ANALYSIS_CLU_2_T_0

  • Service 22DID 107A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2021 to 2026.

Analysis, clutch 2 temperature time in range 1 TAIGO_ANALYSIS_CLU_2_T_1

  • Service 22DID 107B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2021 to 2026.

Analysis, clutch 2 temperature time in range 2 TAIGO_ANALYSIS_CLU_2_T_2

  • Service 22DID 107C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2021 to 2026.

Analysis, clutch 2 temperature time in range 3 TAIGO_ANALYSIS_CLU_2_T_3

  • Service 22DID 107D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2021 to 2026.

Clutch 1 adaptation kiss point part 1 odometer reading TAIGO_PQ35_CLUTCH_1_ADAPT_KISS_POINT_PART_1_ODO_READING

  • Service 22DID 10CA
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2021 to 2026.

Clutch 1 temperature time in range 0 TAIGO_CLU_1_T_TIME_RANGE_0

  • Service 22DID 1065
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2021 to 2026.

Clutch 2 adaptation kiss point part 1 odometer reading TAIGO_PQ35_CLUTCH_2_ADAPT_KISS_POINT_PART_1_ODO_READING

  • Service 22DID 10EB
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2021 to 2026.

Distance since last regeneration TAIGO_DIST_SINCE_REGEN

  • Service 22DID 208D
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2021 to 2026.

Drive cycles counter TAIGO_MQB_TCM_DRIVE_CYCLES_COUNTER

  • Service 22DID 388B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Driving time ecological TAIGO_MQB_TCM_DRIVING_TIME_ECOLOGICAL

  • Service 22DID 3888
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Driving time manual TAIGO_MQB_TCM_DRIVING_TIME_MANUAL

  • Service 22DID 388A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Driving time sporty TAIGO_MQB_TCM_DRIVING_TIME_SPORTY

  • Service 22DID 3889
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Ignition cycles TAIGO_MQB_TCM_IGNITION_CYCLES

  • Service 22DID 388C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Mixture variation in adapted part load range 1 TAIGO_MIXTURE_VARIATION_1

  • Service 22DID 39BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Odometer TAIGO_ODO_7E0_7E0

Pelican can show this parameter as the odometer.

  • Service 22DID 108C
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2021 to 2026.

Odometer TAIGO_ODO_7E1

Pelican can show this parameter as the odometer.

  • Service 22DID 103D
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2021 to 2026.

Odometer #2 TAIGO_MQB_TCM_ODO_2

Pelican can show this parameter as the odometer.

  • Service 22DID 3887
  • Module7E1
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

In testing for 2021, 2023 to 2026. Not supported for 2022.

Odometer at oxidation catalytic converter replacement TAIGO_ODO_OXYDATION

  • Service 22DID 4F3F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2021 to 2026.

Odometer with ECU installed, variant 2 TAIGO_ODO_ECU_INSTALLED_2

  • Service 22DID 295B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 m
Unit
m

In testing for 2021 to 2026.

Odometer, alternate TAIGO_PQ35_ODO_2

Pelican can show this parameter as the odometer.

  • Service 22DID 16A9
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2021 to 2026.

Odometer, alternative TAIGO_ODO_2Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • Module7E0
  • Every30 s
  • Testing for 2021, 2023 to 2026

Example reply from a 2022 Volkswagen Taigo.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x0123F0 = 74736 → 74,736 km

Confirmed for 2022. In testing for 2021, 2023 to 2026.

Odometer, high resolution TAIGO_ODO_HD

Pelican can show this parameter as the odometer.

  • Service 22DID 1160
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2021, 2023 to 2026. Not supported for 2022.

Operating time, temperature range 1 TAIGO_OP_TIME_T_RANGE_1

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860.74294967295
Range
0 to 23860.7 h
Unit
h

In testing for 2021 to 2026.

Operating time, temperature range 2 TAIGO_OP_TIME_T_RANGE_2

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860.74294967295
Range
0 to 23860.7 h
Unit
h

In testing for 2021 to 2026.

Operating time, temperature range 3 TAIGO_OP_TIME_T_RANGE_3

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860.74294967295
Range
0 to 23860.7 h
Unit
h

In testing for 2021 to 2026.

Operating time, temperature range 4 TAIGO_OP_TIME_T_RANGE_4

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860.74294967295
Range
0 to 23860.7 h
Unit
h

In testing for 2021 to 2026.

Operating time, temperature range 5 TAIGO_OP_TIME_T_RANGE_5

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860.74294967295
Range
0 to 23860.7 h
Unit
h

In testing for 2021 to 2026.

Operating time, temperature range 6 TAIGO_OP_TIME_T_RANGE_6

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860.74294967295
Range
0 to 23860.7 h
Unit
h

In testing for 2021 to 2026.

Remaining distance until reducing agent deficiency TAIGO_REMAINING_DIST_UNTIL

  • Service 22DID 29B1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val20
Range
0 to 214748364 km
Unit
km

In testing for 2021 to 2026.

Torque converter time in temperature range 1 TAIGO_TQ_CONV_TIME_T_RANGE_1

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2021 to 2026.

Torque converter time in temperature range 2 TAIGO_TQ_CONV_TIME_T_RANGE_2

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 47 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2021 to 2026.

Torque converter time in temperature range 3 TAIGO_TQ_CONV_TIME_T_RANGE_3

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2021 to 2026.

Torque converter time in temperature range 4 TAIGO_TQ_CONV_TIME_T_RANGE_4

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2021 to 2026.

Torque converter time in temperature range 5 TAIGO_TQ_CONV_TIME_T_RANGE_5

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 119 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2021 to 2026.

Torque converter time in temperature range 6 TAIGO_TQ_CONV_TIME_T_RANGE_6

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 143 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2021 to 2026.

Torque converter time in temperature range 7 TAIGO_TQ_CONV_TIME_T_RANGE_7

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 144 to 167 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2021 to 2026.

Torque converter time in temperature range 8 TAIGO_TQ_CONV_TIME_T_RANGE_8

  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 168 to 191 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2021 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.