Volkswagen Multivan

Parameters

The Volkswagen Multivan has 16 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage MULTIVAN_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2003 to 2005, 2007 to 2026

Example reply from a 2006 Volkswagen Multivan.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x2237 = 8759 → 87591000+4 = 12.759 V

Confirmed for 2006. In testing for 2003 to 2005, 2007 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery charge level MULTIVAN_BAT_SOCConfirmed

  • Service 22DID 2A0C
  • Module710 → 77A
  • Every10 s
  • Testing for 2003 to 2005, 2007 to 2026

Example reply from a 2006 Volkswagen Multivan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x5B = 91 → 91 %

Confirmed for 2006. In testing for 2003 to 2005, 2007 to 2026.

Battery current MULTIVAN_BAT_IConfirmed

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing for 2003 to 2005, 2007 to 2026

Example reply from a 2006 Volkswagen Multivan.

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-1000 to 1000 A
Unit
A

0x00000000 = 0 → 01000 = 0 A

Confirmed for 2006. In testing for 2003 to 2005, 2007 to 2026.

Battery internal resistance MULTIVAN_BAT_INT_RConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2003 to 2005, 2007 to 2026

Example reply from a 2006 Volkswagen Multivan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20100
Range
0 to 51
Unit
Raw value

0x2F = 47 → 47×20100 = 9.4

Confirmed for 2006. In testing for 2003 to 2005, 2007 to 2026.

Battery internal resistance, raw MULTIVAN_BAT_INTERNAL_RES_RAW

  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51
Unit
Raw value

In testing for 2003 to 2026.

Battery temperature MULTIVAN_BAT_TConfirmed

  • Service 22DID 2A0B
  • Module710 → 77A
  • Every5 s
  • Testing for 2003 to 2005, 2007 to 2026

Example reply from a 2006 Volkswagen Multivan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x34 = 52 → 52−40 = 12 °C

Confirmed for 2006. In testing for 2003 to 2005, 2007 to 2026.

Battery voltage MULTIVAN_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2003 to 2005, 2007 to 2026

Example reply from a 2006 Volkswagen Multivan.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x2237 = 8759 → 87591000+4 = 12.759 V

Confirmed for 2006. In testing for 2003 to 2005, 2007 to 2026.

Battery voltage at rest MULTIVAN_BAT_V_AT_RESTConfirmed

  • Service 22DID 2A10
  • Module710 → 77A
  • Every5 s
  • Testing for 2003 to 2005, 2007 to 2026

Example reply from a 2006 Volkswagen Multivan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+9
Range
9 to 34.5 V
Unit
V

0x25 = 37 → 3710+9 = 12.7 V

Confirmed for 2006. In testing for 2003 to 2005, 2007 to 2026.

High voltage battery energy information MULTIVAN_HIGH_V_EM_HVBAT

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 kWh
Unit
kWh

In testing for 2003 to 2026.

High voltage battery energy information MULTIVAN_HVBAT_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638 kWh
Unit
kWh

In testing for 2003 to 2026.

Start/stop battery target voltage MULTIVAN_SSB_VTConfirmed

  • Service 22DID 2A00
  • Module710 → 77A
  • Every1 s
  • Testing for 2003 to 2005, 2007 to 2026

Example reply from a 2006 Volkswagen Multivan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

0x00 = 0 → 010+10.6 = 10.6 V

Confirmed for 2006. In testing for 2003 to 2005, 2007 to 2026.

Start/stop battery total charge MULTIVAN_SSB_TOTAL_CHARGEConfirmed

  • Service 22DID 2A61
  • Module710 → 77A
  • Every1 s
  • Testing for 2003 to 2005, 2007 to 2026

Example reply from a 2006 Volkswagen Multivan.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

0x00015123 = 86307 → 8630710 = 8,630.7 Ah

Confirmed for 2006. In testing for 2003 to 2005, 2007 to 2026.

Start/stop battery total discharge MULTIVAN_SSB_TOTAL_DISCHARGEConfirmed

  • Service 22DID 2A61
  • Module710 → 77A
  • Every1 s
  • Testing for 2003 to 2005, 2007 to 2026

Example reply from a 2006 Volkswagen Multivan.

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

0x00011F0A = 73482 → 7348210 = 7,348.2 Ah

Confirmed for 2006. In testing for 2003 to 2005, 2007 to 2026.

Usable battery charge MULTIVAN_USE_BAT_CHGConfirmed

  • Service 22DID 2A0F
  • Module710 → 77A
  • Every5 s
  • Testing for 2003 to 2005, 2007 to 2026

Example reply from a 2006 Volkswagen Multivan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

0x1C = 28 → 28 Ah

Confirmed for 2006. In testing for 2003 to 2005, 2007 to 2026.

Engine

Energy content MULTIVAN_ENERGY_CONTENT

  • Service 22DID 22E4
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

In testing for 2003 to 2026.

Generator current MULTIVAN_GEN_CURRENT

  • Service 22DID 2A1C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10+9
Range
0 to 6562.5 A
Unit
A

In testing for 2003 to 2026.

NV energy requirement MULTIVAN_NV_ENERGY

  • Service 22DID 1512
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2003 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.