Volkswagen e-Up

Parameters

The Volkswagen e-Up has 248 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage EUP_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 105A
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20
Range
0 to 1310700 mV
Unit
mV

In testing for 2013 to 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery voltage EUP_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 105A
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20
Range
0 to 1310700 mV
Unit
mV

In testing for 2013 to 2023.

Charger AC input current EUP_CHG_AC_I

  • Service 22DID 1DA8
  • Module744
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2013 to 2023.

Charger AC input current setpoint EUP_CHG_AC_I_SET

  • Service 22DID 15D3
  • Module744
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2013 to 2023.

Charger AC input voltage EUP_CHG_AC_V

  • Service 22DID 1DA9
  • Module744
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2013 to 2023.

Charger DC to DC coil temperature EUP_CHG_DCDC_COIL_T

  • Service 22DID 15DA
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2023.

Charger DC to DC gate driver voltage EUP_CHG_DCDC_GATE_V

  • Service 22DID 15DD
  • Module744
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2013 to 2023.

Charger DC to DC power line temperature EUP_CHG_DCDC_LINE_T

  • Service 22DID 15EC
  • Module744
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2023.

Charger output current EUP_CHG_HV_I

  • Service 22DID 4237
  • Module744
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val4
Range
0 to 63.749 A
Unit
A

In testing for 2013 to 2023.

Charger output current setpoint EUP_CHG_HV_I_SET

  • Service 22DID 4238
  • Module744
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val4
Range
0 to 63.749 A
Unit
A

In testing for 2013 to 2023.

Charger output voltage EUP_CHG_OUT_V

  • Service 22DID 1DA7
  • Module744
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2013 to 2023.

Charger power factor coil temperature EUP_CHG_PFC_COIL_T

  • Service 22DID 15D9
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2023.

Charger power factor gate driver voltage EUP_CHG_PFC_GATE_V

  • Service 22DID 15DC
  • Module744
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2013 to 2023.

Charger power loss EUP_CHG_PWR_LOSS

  • Service 22DID 15E1
  • Module744
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100 W
Unit
W

In testing for 2013 to 2023.

Charger temperature EUP_CHG_T

  • Service 22DID 15D8
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2023.

Charging efficiency EUP_CHG_EFFICIENCY

  • Service 22DID 15D6
  • Module744
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+75
Range
0 to 100.499 %
Unit
%

In testing for 2013 to 2023.

DC to DC converter circuit board temperature EUP_DCDC_PCB_T

  • Service 22DID 464E
  • Module7E6
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

DC to DC converter high-voltage side voltage EUP_DCDC_HV_V

  • Service 22DID 1587
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2013 to 2023.

DC to DC converter power stage temperature EUP_DCDC_PWR_T

  • Service 22DID 464F
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

DC to DC converter regulated output voltage EUP_PE_DCDC_KL30_V

  • Service 22DID 465C
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.998 V
Unit
V

In testing for 2013 to 2023.

DC to DC converter temperature EUP_PE_DCDC_T

  • Service 22DID 3EB5
  • Module7E6
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

DC to DC converter traction current EUP_DCDC_HV_I

  • Service 22DID 4650
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.998 A
Unit
A

In testing for 2013 to 2023.

DC to DC converter traction voltage EUP_PE_DCDC_HV_V

  • Service 22DID 465E
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2013 to 2023.

HV battery capacity EUP_HVBAT_CAP

Total possible energy in the high voltage battery

  • Service 22DID 2AB2
  • Module710 → 77A
  • Every86400 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1310770
Range
0 to 3276 kWh
Unit
kWh

In testing for 2013 to 2023.

HV battery cell 1 voltage EUP_HVBAT_CELL_1_V

  • Service 22DID 1E40
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 2 voltage EUP_HVBAT_CELL_2_V

  • Service 22DID 1E41
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 3 voltage EUP_HVBAT_CELL_3_V

  • Service 22DID 1E42
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 4 voltage EUP_HVBAT_CELL_4_V

  • Service 22DID 1E43
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 5 voltage EUP_HVBAT_CELL_5_V

  • Service 22DID 1E44
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 6 voltage EUP_HVBAT_CELL_6_V

  • Service 22DID 1E45
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 7 voltage EUP_HVBAT_CELL_7_V

  • Service 22DID 1E46
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 8 voltage EUP_HVBAT_CELL_8_V

  • Service 22DID 1E47
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 9 voltage EUP_HVBAT_CELL_9_V

  • Service 22DID 1E48
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 10 voltage EUP_HVBAT_CELL_10_V

  • Service 22DID 1E49
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 11 voltage EUP_HVBAT_CELL_11_V

  • Service 22DID 1E4A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 12 voltage EUP_HVBAT_CELL_12_V

  • Service 22DID 1E4B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 13 voltage EUP_HVBAT_CELL_13_V

  • Service 22DID 1E4C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 14 voltage EUP_HVBAT_CELL_14_V

  • Service 22DID 1E4D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 15 voltage EUP_HVBAT_CELL_15_V

  • Service 22DID 1E4E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 16 voltage EUP_HVBAT_CELL_16_V

  • Service 22DID 1E4F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 17 voltage EUP_HVBAT_CELL_17_V

  • Service 22DID 1E50
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 18 voltage EUP_HVBAT_CELL_18_V

  • Service 22DID 1E51
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 19 voltage EUP_HVBAT_CELL_19_V

  • Service 22DID 1E52
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 20 voltage EUP_HVBAT_CELL_20_V

  • Service 22DID 1E53
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 21 voltage EUP_HVBAT_CELL_21_V

  • Service 22DID 1E54
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 22 voltage EUP_HVBAT_CELL_22_V

  • Service 22DID 1E55
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 23 voltage EUP_HVBAT_CELL_23_V

  • Service 22DID 1E56
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 24 voltage EUP_HVBAT_CELL_24_V

  • Service 22DID 1E57
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 25 voltage EUP_HVBAT_CELL_25_V

  • Service 22DID 1E58
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 26 voltage EUP_HVBAT_CELL_26_V

  • Service 22DID 1E59
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 27 voltage EUP_HVBAT_CELL_27_V

  • Service 22DID 1E5A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 28 voltage EUP_HVBAT_CELL_28_V

  • Service 22DID 1E5B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 29 voltage EUP_HVBAT_CELL_29_V

  • Service 22DID 1E5C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 30 voltage EUP_HVBAT_CELL_30_V

  • Service 22DID 1E5D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 31 voltage EUP_HVBAT_CELL_31_V

  • Service 22DID 1E5E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 32 voltage EUP_HVBAT_CELL_32_V

  • Service 22DID 1E5F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 33 voltage EUP_HVBAT_CELL_33_V

  • Service 22DID 1E60
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 34 voltage EUP_HVBAT_CELL_34_V

  • Service 22DID 1E61
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 35 voltage EUP_HVBAT_CELL_35_V

  • Service 22DID 1E62
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 36 voltage EUP_HVBAT_CELL_36_V

  • Service 22DID 1E63
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 37 voltage EUP_HVBAT_CELL_37_V

  • Service 22DID 1E64
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 38 voltage EUP_HVBAT_CELL_38_V

  • Service 22DID 1E65
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 39 voltage EUP_HVBAT_CELL_39_V

  • Service 22DID 1E66
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 40 voltage EUP_HVBAT_CELL_40_V

  • Service 22DID 1E67
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 41 voltage EUP_HVBAT_CELL_41_V

  • Service 22DID 1E68
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 42 voltage EUP_HVBAT_CELL_42_V

  • Service 22DID 1E69
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 43 voltage EUP_HVBAT_CELL_43_V

  • Service 22DID 1E6A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 44 voltage EUP_HVBAT_CELL_44_V

  • Service 22DID 1E6B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 45 voltage EUP_HVBAT_CELL_45_V

  • Service 22DID 1E6C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 46 voltage EUP_HVBAT_CELL_46_V

  • Service 22DID 1E6D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 47 voltage EUP_HVBAT_CELL_47_V

  • Service 22DID 1E6E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 48 voltage EUP_HVBAT_CELL_48_V

  • Service 22DID 1E6F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 49 voltage EUP_HVBAT_CELL_49_V

  • Service 22DID 1E70
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 50 voltage EUP_HVBAT_CELL_50_V

  • Service 22DID 1E71
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 51 voltage EUP_HVBAT_CELL_51_V

  • Service 22DID 1E72
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 52 voltage EUP_HVBAT_CELL_52_V

  • Service 22DID 1E73
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 53 voltage EUP_HVBAT_CELL_53_V

  • Service 22DID 1E74
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 54 voltage EUP_HVBAT_CELL_54_V

  • Service 22DID 1E75
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 55 voltage EUP_HVBAT_CELL_55_V

  • Service 22DID 1E76
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 56 voltage EUP_HVBAT_CELL_56_V

  • Service 22DID 1E77
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 57 voltage EUP_HVBAT_CELL_57_V

  • Service 22DID 1E78
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 58 voltage EUP_HVBAT_CELL_58_V

  • Service 22DID 1E79
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 59 voltage EUP_HVBAT_CELL_59_V

  • Service 22DID 1E7A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 60 voltage EUP_HVBAT_CELL_60_V

  • Service 22DID 1E7B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 61 voltage EUP_HVBAT_CELL_61_V

  • Service 22DID 1E7C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 62 voltage EUP_HVBAT_CELL_62_V

  • Service 22DID 1E7D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 63 voltage EUP_HVBAT_CELL_63_V

  • Service 22DID 1E7E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 64 voltage EUP_HVBAT_CELL_64_V

  • Service 22DID 1E7F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 65 voltage EUP_HVBAT_CELL_65_V

  • Service 22DID 1E80
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 66 voltage EUP_HVBAT_CELL_66_V

  • Service 22DID 1E81
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 67 voltage EUP_HVBAT_CELL_67_V

  • Service 22DID 1E82
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 68 voltage EUP_HVBAT_CELL_68_V

  • Service 22DID 1E83
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 69 voltage EUP_HVBAT_CELL_69_V

  • Service 22DID 1E84
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 70 voltage EUP_HVBAT_CELL_70_V

  • Service 22DID 1E85
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 71 voltage EUP_HVBAT_CELL_71_V

  • Service 22DID 1E86
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 72 voltage EUP_HVBAT_CELL_72_V

  • Service 22DID 1E87
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 73 voltage EUP_HVBAT_CELL_73_V

  • Service 22DID 1E88
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 74 voltage EUP_HVBAT_CELL_74_V

  • Service 22DID 1E89
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 75 voltage EUP_HVBAT_CELL_75_V

  • Service 22DID 1E8A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 76 voltage EUP_HVBAT_CELL_76_V

  • Service 22DID 1E8B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 77 voltage EUP_HVBAT_CELL_77_V

  • Service 22DID 1E8C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 78 voltage EUP_HVBAT_CELL_78_V

  • Service 22DID 1E8D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 79 voltage EUP_HVBAT_CELL_79_V

  • Service 22DID 1E8E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 80 voltage EUP_HVBAT_CELL_80_V

  • Service 22DID 1E8F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 81 voltage EUP_HVBAT_CELL_81_V

  • Service 22DID 1E90
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 82 voltage EUP_HVBAT_CELL_82_V

  • Service 22DID 1E91
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 83 voltage EUP_HVBAT_CELL_83_V

  • Service 22DID 1E92
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 84 voltage EUP_HVBAT_CELL_84_V

  • Service 22DID 1E93
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 85 voltage EUP_HVBAT_CELL_85_V

  • Service 22DID 1E94
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 86 voltage EUP_HVBAT_CELL_86_V

  • Service 22DID 1E95
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 87 voltage EUP_HVBAT_CELL_87_V

  • Service 22DID 1E96
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 88 voltage EUP_HVBAT_CELL_88_V

  • Service 22DID 1E97
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 89 voltage EUP_HVBAT_CELL_89_V

  • Service 22DID 1E98
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 90 voltage EUP_HVBAT_CELL_90_V

  • Service 22DID 1E99
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 91 voltage EUP_HVBAT_CELL_91_V

  • Service 22DID 1E9A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 92 voltage EUP_HVBAT_CELL_92_V

  • Service 22DID 1E9B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 93 voltage EUP_HVBAT_CELL_93_V

  • Service 22DID 1E9C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 94 voltage EUP_HVBAT_CELL_94_V

  • Service 22DID 1E9D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 95 voltage EUP_HVBAT_CELL_95_V

  • Service 22DID 1E9E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 96 voltage EUP_HVBAT_CELL_96_V

  • Service 22DID 1E9F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 97 voltage EUP_HVBAT_CELL_97_V

  • Service 22DID 1EA0
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 98 voltage EUP_HVBAT_CELL_98_V

  • Service 22DID 1EA1
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 99 voltage EUP_HVBAT_CELL_99_V

  • Service 22DID 1EA2
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 100 voltage EUP_HVBAT_CELL_100_V

  • Service 22DID 1EA3
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 101 voltage EUP_HVBAT_CELL_101_V

  • Service 22DID 1EA4
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell 102 voltage EUP_HVBAT_CELL_102_V

  • Service 22DID 1EA5
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell voltage sum EUP_HVBAT_CELL_SUM_V

  • Service 22DID 1E3C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val4096
Range
0 to 4095.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell voltage, maximum EUP_HVBAT_CELL_V_MAX

  • Service 22DID 1E33
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery cell voltage, minimum EUP_HVBAT_CELL_V_MIN

  • Service 22DID 1E34
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.999 V
Unit
V

In testing for 2013 to 2023.

HV battery charge EUP_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

HV battery charge current limit EUP_HVBAT_CHG_I_LIM

  • Service 22DID 1E1B
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2013 to 2023.

HV battery charge current limit, predicted EUP_HVBAT_CHG_I_LIM_PRED

  • Service 22DID 1E1D
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2013 to 2023.

HV battery charge throughput EUP_HVBAT_AH_CHG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val549.31642
Range
0 to 7818700 Ah
Unit
Ah

In testing for 2013 to 2023.

HV battery charge, displayed EUP_HVBAT_SOC_DISP

Pelican can show this parameter as the state of charge.

  • Service 22DID 1164
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

HV battery charge, normalized EUP_PE_SOC

  • Service 22DID F404
  • Module7E6
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

HV battery coldest sensor EUP_HVBAT_T_MIN_NO

  • Service 22DID 1E0F
  • Module7E5
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2023.

HV battery current EUP_HVBAT_I

Pelican can show this parameter as the traction battery current.

  • Service 22DID 1E3D
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−511
Range
-200 to 200 A
Unit
A

In testing for 2013 to 2023.

HV battery discharge current limit EUP_HVBAT_DISCHG_I_LIM

  • Service 22DID 1E1C
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2013 to 2023.

HV battery discharge current limit, predicted EUP_HVBAT_DISCHG_I_LIM_PRED

  • Service 22DID 1E1E
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2013 to 2023.

HV battery discharge throughput EUP_HVBAT_AH_DISCHG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
val549.31642
Range
-3909350 to 3909350 Ah
Unit
Ah

In testing for 2013 to 2023.

HV battery energy EUP_HVBAT_KWH

Energy stored in the high voltage battery

  • Service 22DID 2AB8
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1310770
Range
0 to 3276 kWh
Unit
kWh

In testing for 2013 to 2023.

HV battery energy charged EUP_HVBAT_KWH_CHG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val8583.07212
Range
0 to 500300 kWh
Unit
kWh

In testing for 2013 to 2023.

HV battery energy discharged EUP_HVBAT_KWH_DISCHG

  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The value is signed.

Formula
val8583.07212
Range
-250199.883 to 250199.883 kWh
Unit
kWh

In testing for 2013 to 2023.

HV battery health EUP_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID 51E0
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.127−1798.574
Range
-1798.574 to 100 %
Unit
%

In testing for 2013 to 2023.

HV battery highest cell EUP_HVBAT_CELL_V_MAX_NO

  • Service 22DID 1E33
  • Module7E5
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2023.

HV battery hottest sensor EUP_HVBAT_T_MAX_NO

  • Service 22DID 1E0E
  • Module7E5
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2023.

HV battery isolation resistance, negative EUP_HVBAT_ISO_NEG

  • Service 22DID 1E1A
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2013 to 2023.

HV battery isolation resistance, positive EUP_HVBAT_ISO_POS

  • Service 22DID 1E18
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2013 to 2023.

HV battery lowest cell EUP_HVBAT_CELL_V_MIN_NO

  • Service 22DID 1E34
  • Module7E5
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2023.

HV battery maximum power EUP_HVBAT_PWR_MAX

  • Service 22DID 1502
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4
Range
0 to 262140 W
Unit
W

In testing for 2013 to 2023.

HV battery negative voltage before the contactors EUP_HVBAT_NEG_V_PRE

  • Service 22DID 1E35
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 V
Unit
V

In testing for 2013 to 2023.

HV battery positive voltage after the charging contactors EUP_HVBAT_POS_V_POST_CHG

  • Service 22DID 1E39
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 V
Unit
V

In testing for 2013 to 2023.

HV battery positive voltage before the contactors EUP_HVBAT_POS_V_PRE

  • Service 22DID 1E36
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2013 to 2023.

HV battery power EUP_HVBAT_PWR

  • Service 22DID 1485
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 kW
Unit
kW

In testing for 2013 to 2023.

HV battery relative temperature EUP_HVBAT_T_REL

  • Service 22DID 149B
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2013 to 2023.

HV battery remaining charge EUP_HVBAT_REMAINING

  • Service 22DID F45B
  • Module7E0
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

HV battery temperature EUP_HVBAT_T

  • Service 22DID 2A0B
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature load EUP_HVBAT_T_LOAD

  • Service 22DID 1165
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2013 to 2023.

HV battery temperature sensor 1 EUP_HVBAT_T_1

  • Service 22DID 1EAE
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 2 EUP_HVBAT_T_2

  • Service 22DID 1EAF
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 3 EUP_HVBAT_T_3

  • Service 22DID 1EB0
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 4 EUP_HVBAT_T_4

  • Service 22DID 1EB1
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 5 EUP_HVBAT_T_5

  • Service 22DID 1EB2
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 6 EUP_HVBAT_T_6

  • Service 22DID 1EB3
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 7 EUP_HVBAT_T_7

  • Service 22DID 1EB4
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 8 EUP_HVBAT_T_8

  • Service 22DID 1EB5
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 9 EUP_HVBAT_T_9

  • Service 22DID 1EB6
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 10 EUP_HVBAT_T_10

  • Service 22DID 1EB7
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 11 EUP_HVBAT_T_11

  • Service 22DID 1EB8
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 12 EUP_HVBAT_T_12

  • Service 22DID 1EB9
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 13 EUP_HVBAT_T_13

  • Service 22DID 1EBA
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 15 EUP_HVBAT_T_15

  • Service 22DID 1EBC
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 16 EUP_HVBAT_T_16

  • Service 22DID 1EBD
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature sensor 17 EUP_HVBAT_T_17

  • Service 22DID 7425
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery temperature, maximum EUP_HVBAT_T_MAX

  • Service 22DID 1E0E
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

HV battery voltage EUP_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1000 V
Unit
V

In testing for 2013 to 2023.

HV interlock detector voltage EUP_HV_INTERLOCK_DET_V

  • Service 22DID 74B9
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3276
Range
0 to 20.004 V
Unit
V

In testing for 2013 to 2023.

HV interlock source current EUP_HV_INTERLOCK_SRC_I

  • Service 22DID 74BC
  • Module7E5
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 mA
Unit
mA

In testing for 2013 to 2023.

HV interlock source voltage EUP_HV_INTERLOCK_SRC_V

  • Service 22DID 74BA
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3276
Range
0 to 20.004 V
Unit
V

In testing for 2013 to 2023.

HV system isolation resistance, negative EUP_HV_ISO_NEG_SYS

  • Service 22DID 1E19
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2013 to 2023.

HV system isolation resistance, positive EUP_HV_ISO_POS_SYS

  • Service 22DID 1E17
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2013 to 2023.

Onboard electrical system current EUP_AUX_I

  • Service 22DID 1617
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 A
Unit
A

In testing for 2013 to 2023.

Onboard electrical system power EUP_AUX_PWR

  • Service 22DID 1077
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4
Range
0 to 262140 W
Unit
W

In testing for 2013 to 2023.

Power electronics terminal 30 voltage EUP_PE_KL30_V

  • Service 22DID 465D
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.998 V
Unit
V

In testing for 2013 to 2023.

Terminal 30 voltage EUP_KL30_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

In testing for 2013 to 2023.

Traction current reported by the battery management system EUP_PE_BMS_HV_I

  • Service 22DID 465F
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2013 to 2023.

Traction voltage reported by the battery management system EUP_PE_BMS_HV_V

  • Service 22DID 466E
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2013 to 2023.

Climate

Air conditioning refrigerant pressure EUP_AC_REFRIG_P

  • Service 22DID 1017
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kPa
Unit
kPa

In testing for 2013 to 2023.

Ambient air temperature EUP_AAT

  • Service 22DID F446
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2023.

Ambient air temperature, cluster EUP_DASH_AAT

  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2013 to 2023.

Barometric pressure EUP_BARO

  • Service 22DID F433
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2013 to 2023.

PTC heater current EUP_PTC_HEATER_I

  • Service 22DID 1604
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.937 A
Unit
A

In testing for 2013 to 2023.

Control

Accelerator pedal position EUP_APP_PE

  • Service 22DID F449
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

Accelerator pedal position 1 EUP_APP1

  • Service 22DID F449
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

Accelerator pedal position 2 EUP_APP2

  • Service 22DID F44A
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2013 to 2023.

Accelerator pedal release detection threshold voltage EUP_APP_REDUCE_V

  • Service 22DID 1029
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2013 to 2023.

Accelerator pedal sensor 1 voltage EUP_APP_V1

  • Service 22DID 102A
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2013 to 2023.

Accelerator pedal sensor 2 voltage EUP_APP_V2

  • Service 22DID 102B
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2013 to 2023.

Downshift point adaptation voltage EUP_DOWNSHIFT_ADAPT_V

  • Service 22DID 1028
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2013 to 2023.

DTCs

Distance traveled since diagnostic trouble codes cleared EUP_CLR_DIST

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2013 to 2023.

Distance traveled while mil was activated EUP_MIL_DIST

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2013 to 2023.

Number of warm-ups since diagnostic trouble codes cleared EUP_WARM_UPS

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2023.

Engine

Drive motor current EUP_MOTOR_I

  • Service 22DID 147D
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.968 A
Unit
A

In testing for 2013 to 2023.

Drive motor effective current EUP_MOTOR_I_RMS

  • Service 22DID 4665
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.937 A
Unit
A

In testing for 2013 to 2023.

Drive motor phase U current EUP_MOTOR_U_I

  • Service 22DID 3EF9
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2013 to 2023.

Drive motor phase U current, unlimited EUP_MOTOR_U_I_RAW

  • Service 22DID 4671
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2013 to 2023.

Drive motor phase V current EUP_MOTOR_V_I

  • Service 22DID 3EFA
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2013 to 2023.

Drive motor phase V current, unlimited EUP_MOTOR_V_I_RAW

  • Service 22DID 4670
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2013 to 2023.

Drive motor phase W current EUP_MOTOR_W_I

  • Service 22DID 3EFB
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2013 to 2023.

Drive motor phase W current, unlimited EUP_MOTOR_W_I_RAW

  • Service 22DID 466F
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 A
Unit
A

In testing for 2013 to 2023.

Drive motor power EUP_MOTOR_PWR

  • Service 22DID 147E
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 kW
Unit
kW

In testing for 2013 to 2023.

Drive motor power, actual EUP_MOTOR_PWR_PE

  • Service 22DID 4656
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.984 kW
Unit
kW

In testing for 2013 to 2023.

Drive motor power, calculated EUP_MOTOR_PWR_CALC

  • Service 22DID 4658
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.984 kW
Unit
kW

In testing for 2013 to 2023.

Drive motor speed EUP_MOTOR_RPM_ECM

  • Service 22DID 149A
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2013 to 2023.

Drive motor speed 2 EUP_MOTOR_RPM_2

  • Service 22DID 3EEC
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2013 to 2023.

Drive motor speed, actual EUP_MOTOR_RPM

Pelican can show this parameter as the engine speed.

  • Service 22DID 3E97
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2013 to 2023.

Drive motor speed, measured EUP_MOTOR_RPM_ACT

  • Service 22DID 4659
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2013 to 2023.

Drive motor speed, standard EUP_MOTOR_RPM_SAE

  • Service 22DID F40C
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.749 rpm
Unit
rpm

In testing for 2013 to 2023.

Drive motor stator temperature EUP_MOTOR_STATOR_T

  • Service 22DID 4672
  • Module7E6
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

Drive motor temperature EUP_MOTOR_T

  • Service 22DID 3E94
  • Module7E6
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

Drive motor torque EUP_MOTOR_TQ

  • Service 22DID 147F
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val3
Range
-10922.666 to 10922.333 N·m
Unit
N·m

In testing for 2013 to 2023.

Drive motor torque, actual EUP_MOTOR_TQ_PE

  • Service 22DID 3EE9
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 N·m
Unit
N·m

In testing for 2013 to 2023.

Drive motor torque, calculated EUP_MOTOR_TQ_CALC

  • Service 22DID 0308
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.937 N·m
Unit
N·m

In testing for 2013 to 2023.

Drive motor voltage EUP_MOTOR_V

  • Service 22DID 1484
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2013 to 2023.

Power electronics internal supply voltage 1 EUP_PE_SUPPLY_V1

  • Service 22DID 466C
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 V
Unit
V

In testing for 2013 to 2023.

Power electronics internal supply voltage 2 EUP_PE_SUPPLY_V2

  • Service 22DID 466B
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 V
Unit
V

In testing for 2013 to 2023.

Power electronics phase U transistor temperature EUP_PE_IGBT_U_T

  • Service 22DID 4664
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

Power electronics phase V transistor temperature EUP_PE_IGBT_V_T

  • Service 22DID 4663
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

Power electronics phase W transistor temperature EUP_PE_IGBT_W_T

  • Service 22DID 4662
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.984 °C
Unit
°C

In testing for 2013 to 2023.

Power electronics traction voltage EUP_PE_HV_V

  • Service 22DID 4675
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.968 V
Unit
V

In testing for 2013 to 2023.

Power electronics transistor supply voltage EUP_PE_IGBT_SUPPLY_V

  • Service 22DID 465A
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.998 V
Unit
V

In testing for 2013 to 2023.

Rotor position sensor cosine amplitude EUP_ROTOR_COS_AMP_V

  • Service 22DID 4E91
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 V
Unit
V

In testing for 2013 to 2023.

Rotor position sensor cosine offset EUP_ROTOR_COS_OFS_V

  • Service 22DID 4E93
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 V
Unit
V

In testing for 2013 to 2023.

Rotor position sensor cosine track EUP_ROTOR_COS

  • Service 22DID 4661
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2023.

Rotor position sensor sine amplitude EUP_ROTOR_SIN_AMP_V

  • Service 22DID 4E90
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 V
Unit
V

In testing for 2013 to 2023.

Rotor position sensor sine track EUP_ROTOR_SIN

  • Service 22DID 4660
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2023.

Rotor position sensor sine voltage EUP_ROTOR_SIN_V

  • Service 22DID 4E92
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 V
Unit
V

In testing for 2013 to 2023.

Movement

Vehicle speed EUP_VSS

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2013 to 2023.

Stats

Crashes, driver side EUP_CRASH_DRVR

  • Service 22DID 2354
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2013 to 2023.

Crashes, front EUP_CRASH_FRONT

  • Service 22DID 2353
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2013 to 2023.

Crashes, passenger side EUP_CRASH_PASS

  • Service 22DID 2355
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2013 to 2023.

Crashes, rear EUP_CRASH_REAR

  • Service 22DID 2356
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2013 to 2023.

Rollovers EUP_ROLLOVER

  • Service 22DID 2357
  • Module715 → 77F
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2013 to 2023.

Trips

Odometer EUP_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 2203
  • Module714 → 77E
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2013 to 2023.

Range remaining, displayed EUP_RANGE_DSP

Pelican can show this parameter as the electric range.

  • Service 22DID 22E0
  • Module714 → 77E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2013 to 2023.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.