Toyota Vios

Parameters

The Toyota Vios has 277 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Cruise control speed VIOS_CC_SConfirmed

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2010, 2012 to 2023

Example reply from a 2011 Toyota Vios.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2011. In testing for 2007 to 2010, 2012 to 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

+BM voltage VIOS_BM_V

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2007 to 2023.

Battery current VIOS_BAT_CURRENT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5013107−125
Range
-125 to 124.9 A
Unit
A

In testing for 2007 to 2023.

Battery temperature VIOS_BAT_T

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 6513.5 °C
Unit
°C

In testing for 2007 to 2023.

Battery voltage VIOS_BATTERY_VOLTAGE_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2007 to 2023.

Charge contactor current VIOS_SCC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2007 to 2023.

Main connector solenoid current VIOS_SMC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2007 to 2023.

Main relay a, solenoid current VIOS_SLA_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2007 to 2023.

Main relay r solenoid current VIOS_SLR_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2007 to 2023.

Output speed sensor voltage VIOS_NOUT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 2007 to 2023.

Regenerative braking cooperation VIOS_REGEN_COOPERATION

  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Regenerative operation VIOS_FR_REGEN_OPERATION

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2007 to 2023.

Regenerative request VIOS_FR_REGEN_REQUEST

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2007 to 2023.

Relay control solenoid current VIOS_SRC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2007 to 2023.

Service contactor solenoid current VIOS_SSC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2007 to 2023.

Turbine speed sensor voltage VIOS_NT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 2007 to 2023.

Climate

Communication with air conditioner VIOS_COMM_WITH_AIR_CONDITIONER

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Communication with HV VIOS_COMMUNICATION_WITH_HV

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Communication with valvematic VIOS_COMM_WITH_VALVEMATIC_COMM

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Control

A/C compressor VIOS_A_C_COMPRESSOR

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 64 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Accelerator sensor voltage, 1 VIOS_ACCEL_SENS_1_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2023.

Accelerator sensor voltage, 2 VIOS_ACCEL_SENS_2_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2023.

Anti-lock brake warning light VIOS_ABS_WARN

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Brake warning light VIOS_BRAKE_WARN

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Buzzer VIOS_BUZZER

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Communication with brake VIOS_COMMUNICATION_WITH_BRAKE

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Cruise control live brake cancel VIOS_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCH

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Electrical load signal 1 VIOS_ELECTRICAL_LOAD_SIGNAL_1

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Electrical load signal 2 VIOS_ELECTRICAL_LOAD_SIGNAL_2

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Electronically controlled brake warning light VIOS_ECB_WARN

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Ignition trigger count VIOS_IGNITION_TRIG_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2023.

Main idle VIOS_MAIN_IDLE_SW

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Neutral position VIOS_NEUTRAL_POSITION_SW_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Parking brake VIOS_PARKING_BRAKE_SW

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Pattern switch VIOS_PATTERN_SWITCH_PWR_M

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Power steering VIOS_POWER_STEERING_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Reservoir warning VIOS_RESERVOIR_WARNING_SW

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Shift SW status, drive VIOS_SHIFT_SW_STATUS_D_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Shift SW status, neutral VIOS_SHIFT_SW_STATUS_N_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Shift SW status, parking VIOS_SHIFT_SW_STATUS_P_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Shift SW status, reverse VIOS_SHIFT_SW_STATUS_R_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Slip indicator light VIOS_SLIP_WARN

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Sports mode selection VIOS_SPORTS_MODE_SELECTION_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Sports shift down VIOS_SPORTS_SHIFT_DOWN_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Sports shift up VIOS_SPORTS_SHIFT_UP_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Starter control VIOS_STARTER_CONTROL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Starter signal VIOS_STARTER_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

TC VIOS_TC_TERMINAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 61 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Traction control, brake status VIOS_TRC_TRAC__BRAKE_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Cruise control

Cruise control speed VIOS_CC_SConfirmed

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2010, 2012 to 2023

Example reply from a 2011 Toyota Vios.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2011. In testing for 2007 to 2010, 2012 to 2023.

Details

Inspection mode VIOS_INSPECTION_MODE

  • Service 21PID A6
  • Module7B0 → 7B8
  • Every60 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

DTCs

2nd air monitor available? VIOS_2ND_AIR_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

2nd air monitor incomplete? VIOS_2ND_AIR_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

A/C monitor available? VIOS_A_C_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

A/C monitor incomplete? VIOS_A_C_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Catalyst monitor available? VIOS_CATALYST_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Catalyst monitor incomplete? VIOS_CATALYST_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Complete parts monitor available? VIOS_COMPLETE_PARTS_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

EGR/VVT monitor available? VIOS_EGR_VVT_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

EGR/VVT monitor incomplete? VIOS_EGR_VVT_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

EVAP monitor available? VIOS_EVAP_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

EVAP monitor_icmpl VIOS_EVAP_MONITOR_ICMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Fuel system monitor available? VIOS_FUEL_SYSTEM_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Heated catalyst monitor available? VIOS_HEATED_CATALYST_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Heated catalyst monitor incomplete? VIOS_HEATED_CATALYST_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

MIL VIOS_MIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

MIL ON run distance VIOS_MILON_RUN_DISTANCE

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2007 to 2023.

Misfire monitor available? VIOS_MISFIRE_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Number of emission DTC VIOS_NUMBER_OF_EMISSION_DTC

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

In testing for 2007 to 2023.

O2S heater monitor available? VIOS_O2S_A_FS_HEATER_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

O2S heater monitor incomplete? VIOS_O2S_A_FS_HEATER_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

O2S monitor available? VIOS_O2S_A_FS_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

O2S monitor incomplete? VIOS_O2S_A_FS_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Running time from MIL ON VIOS_RUNNING_TIME_FROM_MIL_ON

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2007 to 2023.

Engine

A/F heater duty bank 1 sensor 1 VIOS_F_HEATER_DUTY_B1S1

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2007 to 2023.

A/F test results 1, incomplete VIOS_F_TEST_RESULTS_1

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Accessory relay on VIOS_ACC_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Accumulator open VIOS_ACCUMULATOR_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Acoustic control induction system vacuum switching valve on VIOS_ACIS_VSV_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Actual engine torque VIOS_ACT_ENG_TQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2007 to 2023.

Actuator power supply on VIOS_ACTUATOR_POWER_SUP_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 146 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Air conditioning compressor VIOS_AC_COMP

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Air-fuel equivalence ratio, bank 1 sensor 1 VIOS_AF_LAMBDA_B1S1

Pelican can show this parameter as the O2 lambda.

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

In testing for 2007 to 2023.

Air-fuel sensor current, bank 1 sensor 1 VIOS_AFS_I_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.99 mA
Unit
mA

In testing for 2007 to 2023.

Air-fuel sensor voltage, bank 1 sensor 1 VIOS_AFS_V_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×7.9965535
Range
0 to 7.99 V
Unit
V

In testing for 2007 to 2023.

Alt voltage - active test VIOS_ALT_VOL_ACTIVE_TEST

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2007 to 2023.

Alt voltage - non active test VIOS_ALT_VOL_NON_ACTIVE

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2007 to 2023.

Alternator output duty VIOS_ALTERNATOR_OUTPUT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2007 to 2023.

Atmospheric pressure VIOS_ATMOSPHERE_PRESSURE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2007 to 2023.

Calculated load VIOS_CALCULATED_LOAD_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2023.

Catalyst temperature, bank 1 sensor 1 VIOS_CAT_T_B1S1

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2007 to 2023.

Catalyst temperature, bank 1 sensor 2 VIOS_CAT_T_B1S2

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2007 to 2023.

Catalyst temperature, bank 1 sensor 2, variant 2 VIOS_CAT_T_B1S2_V2

  • Service 21PID 3E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2007 to 2023.

Check mode on VIOS_CHECK_MODE_ON

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Closed throttle position switch on VIOS_CLOSED_THROTTLE_POS_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 125 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Codes, include history VIOS_CODES_INCLUDE

  • Service 21PID E1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2023.

Continuously variable transmission learning complete VIOS_CVT_LEARNED

  • Service 21PID DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2007 to 2023.

Continuously variable transmission oil pressure VIOS_CVT_OIL_P

  • Service 21PID BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200 kPa
Unit
kPa

In testing for 2007 to 2023.

Coolant temperature VIOS_COOLANT_TEMP_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2023.

Cruise control on VIOS_CRUISE_CTRL_ON

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Cylinder number VIOS_CYLINDER_NUMBER

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2023.

Destination VIOS_DESTINATION

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2023.

Dist battery cable disconnect VIOS_DIST_BATT_CABLE

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2007 to 2023.

Electric fan motor on VIOS_ELEC_FAN_MOTOR_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Engine independent VIOS_ENG_INDEPENDENT

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 91 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Engine independent control VIOS_ENG_INDEPENDENT_CTRL

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Engine run time VIOS_ENGINE_RUN_TIME

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2007 to 2023.

Engine run time, up to 255 sec. only VIOS_ENG_RUN_TIME_UP_255

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2007 to 2023.

Engine speed VIOS_ENGINE_SPEED_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2007 to 2023.

Engine stall control FB flow VIOS_ENG_STALL_CTRL_FB

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096−40
Range
-40 to 39.99
Unit
Number

In testing for 2007 to 2023.

Evaporative purge duty VIOS_EVAP_PURGE_DUTY_7E0

  • Service 21PID 2E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2023.

Evaporative purge flow VIOS_EVAP_PURGE_FLOW

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.99 %
Unit
%

In testing for 2007 to 2023.

Evaporative purge vacuum switching valve on VIOS_EVAP_PURGE_VSV_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Exhaust gas recirculation step position VIOS_EGR_STEP_POSITIONConfirmed

  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2007 to 2010, 2012 to 2023

Example reply from a 2011 Toyota Vios.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x82 = 130 → 130

Confirmed for 2011. In testing for 2007 to 2010, 2012 to 2023.

Exhaust gas recirculation temperature VIOS_EGR_T

  • Service 21PID ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5385
Range
0 to 159 °C
Unit
°C

In testing for 2007 to 2023.

Exhaust gas recirculation valve step VIOS_EGR_STEP

  • Service 21PID E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2023.

Fuel cut for engine stop request VIOS_F_C_ENG_STOP_REQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 92 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Fuel cut TAU on VIOS_FC_TAU_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

G sensor calibration, complete VIOS_G_SENS_CALIBRATION

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

G sensor learning value VIOS_G_SENS_LEARNING

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2007 to 2023.

Hydraulic valve, communication open VIOS_HV_COMM_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Idle control VIOS_IDLE_CTRL

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Idle spark advance control 1 VIOS_IDLE_SPARK_ADVN_CTRL_1

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2007 to 2023.

Idle spark advance control 2 VIOS_IDLE_SPARK_ADVN_CTRL_2

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2007 to 2023.

Idle spark advance control 3 VIOS_IDLE_SPARK_ADVN_CTRL_3

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2007 to 2023.

Idle spark advance control 4 VIOS_IDLE_SPARK_ADVN_CTRL_4

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2007 to 2023.

Idle speed control learning VIOS_IDLE_SPD_CTRL

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 93 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Idle speed control learning value, l/s VIOS_IDLE_SPD_CTRL_L_S

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val×0.0012206912
Range
0 to 79.99
Unit
Number

In testing for 2007 to 2023.

IG OFF elapsed time VIOS_IG_OFF_ELAPSED_TIME

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 min
Unit
min

In testing for 2007 to 2023.

Ignition advance VIOS_SPARKADV_21

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2007 to 2023.

Ignition timing advance VIOS_IGN_ADVANCE

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2007 to 2023.

Immobilizer communication on VIOS_IMMOBILIZER_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 120 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Initial engine coolant temperature VIOS_INITIAL_ECT

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×531850−40
Range
-40 to 119.3
Unit
Number

In testing for 2007 to 2023.

Initial intake air temperature VIOS_INITIAL_IAT

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 2007 to 2023.

Injection duration for cylinder 1 VIOS_INJ_DUR_CYL_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2007 to 2023.

Injection volume per 10 injections, cylinder 1 VIOS_INJ_VOL_CYL_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32000000
Range
0 to 0.002 L
Unit
L

In testing for 2007 to 2023.

Injector pulse width VIOS_INJ_PW

  • Service 21PID E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1631275
Range
0 to 32.6 ms
Unit
ms

In testing for 2007 to 2023.

Injector pulse width VIOS_INJ_WIDTH

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 2007 to 2023.

Input shaft speed VIOS_SPD_NIN

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2007 to 2023.

Intake air temperature VIOS_IAT_21

  • Service 21PID 0F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2023.

Intake air temperature VIOS_INTAKE_AIR_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2023.

Judge time engine ignition VIOS_JUDGE_TIME_ENG_IGN

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2007 to 2023.

Judge time engine output VIOS_JUDGE_TIME_ENG

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2007 to 2023.

Knock adjust VIOS_KNOCK_ADJUST

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 2007 to 2023.

Knock adjust VIOS_KNOCK_ADJUST_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

In testing for 2007 to 2023.

Knock correct learn value VIOS_KNOCK_CORRECT_LEARN

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val32−1024
Range
-1024 to 1023 °
Unit
°

In testing for 2007 to 2023.

Knock feedback VIOS_KNOCK_FEEDBACK

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 2007 to 2023.

Knock feedback VIOS_KNOCK_FEEDBACK_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

In testing for 2007 to 2023.

Long term fuel trim, bank 1 VIOS_LONG_FT_B1

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.21 %
Unit
%

In testing for 2007 to 2023.

Long term fuel trim, bank 2 VIOS_LONG_FT_B2

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.21 %
Unit
%

In testing for 2007 to 2023.

Long-term fuel trim, bank 1 VIOS_LTFT1_21

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.7809803922−100
Range
-100 to 99.15 %
Unit
%

In testing for 2007 to 2023.

Manifold absolute pressure VIOS_MAP_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2007 to 2023.

Mass air flow VIOS_MAF_21

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 g/s
Unit
g/s

In testing for 2007 to 2023.

Mass air flow VIOS_MAF_7E0

Pelican can show this parameter as the mass air flow.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

In testing for 2007 to 2023.

Master cylinder open VIOS_MASTER_CYLINDER_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Misfire RPM VIOS_MISFIRE_RPM_7E0

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2007 to 2023.

Misfire test result, incomplete VIOS_MIS_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Model year VIOS_MODEL_YEAR

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val+1900
Range
1900 to 2155
Unit
Number

In testing for 2007 to 2023.

O2 heater b1s2_active VIOS_O2_HEATER_B1S2

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 68 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

O2 heater current val bank 1 sensor 2 VIOS_O2_HEATER_CURR_VAL

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 A
Unit
A

In testing for 2007 to 2023.

Open side malfunction on VIOS_OPEN_SIDE_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 145 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Output shaft speed VIOS_SPD_NOUT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2007 to 2023.

OXS1, A/FS2 test result, incomplete VIOS_OXS1_FS2_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Oxygen sensor voltage, bank 1 sensor 1 VIOS_O2S11_V

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.0049960784
Range
0 to 1.27 V
Unit
V

In testing for 2007 to 2023.

Oxygen sensor voltage, bank 1 sensor 2 VIOS_O2S_B1S2

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×51000
Range
0 to 1.275 V
Unit
V

In testing for 2007 to 2023.

Purge cut vacuum switching valve duty VIOS_PURGE_CUT_VSV_DUTY

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2007 to 2023.

Racing operation VIOS_RACING_OPERATION

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 90 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Request engine run time VIOS_REQ_ENG_RUN_TIME

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2007 to 2023.

Request warm-up VIOS_REQ_WARM_UP

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 89 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Requested engine torque VIOS_REQ_ENG_TQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383
Unit
Number

In testing for 2007 to 2023.

Short term fuel trim, bank 1 VIOS_SHORT_FT_B1

Pelican can show this parameter as the short term fuel trim.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.21 %
Unit
%

In testing for 2007 to 2023.

Short term fuel trim, bank 2 VIOS_SHORT_FT_B2

Pelican can show this parameter as the short term fuel trim.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.21 %
Unit
%

In testing for 2007 to 2023.

Starter relay on VIOS_STARTER_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Stroke open VIOS_STROKE_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

System guard on VIOS_SYSTEM_GUARD_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 144 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Throttle fully close learn VIOS_THROTTLE_FULLY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2007 to 2023.

Throttle idle position on VIOS_THROTTLE_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 149 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Throttle motor current VIOS_THROTTLE_MOTOR

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×564
Range
0 to 19.9 A
Unit
A

In testing for 2007 to 2023.

Throttle motor duty VIOS_THROTTLE_MOTOR_DUTY

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2023.

Throttle motor duty, close VIOS_THROTTLE_MOTOR_DUTY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2007 to 2023.

Throttle motor duty, open VIOS_THROTTLE_MOTOR_DUTY_OPEN

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2007 to 2023.

Throttle position VIOS_THROTTLE_21

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2007 to 2023.

Throttle position command VIOS_THROTTLE_POS_COMMAND

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2007 to 2023.

Throttle position, number 1 VIOS_THROTTLE_POS_NUMBER_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2007 to 2023.

Throttle position, number 2 VIOS_THROTTLE_POS_NUMBER_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2007 to 2023.

Throttle require position VIOS_THROTTLE_REQUIRE_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2007 to 2023.

Throttle sensor open position 1 VIOS_THROTTLE_SENS_OPEN_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2007 to 2023.

Throttle sensor open position 2 VIOS_THROTTLE_SENS_OPEN_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2007 to 2023.

Throttle sensor position VIOS_THROTTLE_SENSOR_POSITION

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2023.

Throttle sensor voltage, 1 VIOS_THROTTLE_SENSOR_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2023.

Throttle sensor voltage, 2 VIOS_THROTTLE_SENSOR_2_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2023.

Time since DTCs cleared VIOS_TIME_SINCE_DTC_CLEARED

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2007 to 2023.

Total fuel trim, bank 1 VIOS_TOT_FT_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100256−50
Range
-50 to 49.6 %
Unit
%

In testing for 2007 to 2023.

Transmission output shaft speed VIOS_TRANS_OUT_RPM

  • Service 21PID BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2007 to 2023.

Turbine speed VIOS_SPD_NT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2007 to 2023.

Valvematic current angle VIOS_VALVEMATIC_CURRENT

  • Service 21PID 31
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 2007 to 2023.

Valvematic, target angle VIOS_VALVEMATIC_TGT_ANG

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 2007 to 2023.

Variable valve timing aim angle 1 VIOS_VARIABLE_VLV_TIM_AIM_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333218450
Range
0 to 399 %
Unit
%

In testing for 2007 to 2023.

Variable valve timing change angle 1 VIOS_VARIABLE_VLV_TIM_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.0097642481
Range
0 to 639 °
Unit
°

In testing for 2007 to 2023.

Variable valve timing control status 1 on VIOS_VARIABLE_VLV_TIM_1_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Variable valve timing oil control valve duty 1 VIOS_VARIABLE_VLV_TIM_OIL_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0061020829
Range
0 to 399 %
Unit
%

In testing for 2007 to 2023.

Vehicle speed VIOS_VSS_21

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2007 to 2023.

Vehicle speed sensor test result, incomplete VIOS_SPD_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Warm-up cycles since DTCs cleared VIOS_WARMUP_CYCLES_DTC_CLEARED

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2023.

Misfires

All cylinders misfire count VIOS_ALL_CYLINDERS_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2023.

Cylinder #1 misfire count VIOS_CYL1_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2023.

Cylinder #2 misfire count VIOS_CYL2_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2023.

Cylinder #3 misfire count VIOS_CYL3_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2023.

Cylinder #4 misfire count VIOS_CYL4_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2023.

Misfire load VIOS_MISFIRE_LOAD_7E0

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×4256
Range
0 to 3.98
Unit
Number

In testing for 2007 to 2023.

Misfire margin VIOS_MISFIRE_MARGIN_7E0

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 %
Unit
%

In testing for 2007 to 2023.

Fuel

Fuel cut VIOS_FUEL_CUT

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Fuel cut VIOS_FUEL_CUT_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 121 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Fuel cut time VIOS_FUEL_CUT_TIME

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×537512
Range
0 to 68734.9511
Unit
Number

In testing for 2007 to 2023.

Fuel injection timing VIOS_FUEL_INJ_TIM

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 2007 to 2023.

Fuel pump/speed status on VIOS_FUEL_PMP_SPD_STAT_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Target air-fuel equivalence ratio VIOS_LAMBDA_TARGET

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

In testing for 2007 to 2023.

Lights

Hazard switch history VIOS_HAZARD_SWITCH_HISTORY

  • Service 21PID BC
  • Module7B0 → 7B8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0INCOMPLETEIncomplete
1COMPLETEComplete

In testing for 2007 to 2023.

Stop light VIOS_STOP_LIGHT_SW

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Stop light VIOS_STOP_LIGHT_SWITCH

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Stop light relay VIOS_STOP_LIGHT_RELAY

  • Service 21PID 3C
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Movement

Accelerator fully close learn 1 VIOS_ACCEL_FULLY_CLOSE_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

In testing for 2007 to 2023.

Accelerator fully close learn 2 VIOS_ACCEL_FULLY_CLOSE_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

In testing for 2007 to 2023.

Accelerator idle position on VIOS_ACCEL_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 148 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Accelerator position VIOS_ACCEL_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2007 to 2023.

Accelerator sensor out, number 1 VIOS_ACCEL_SENS_OUT_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2007 to 2023.

Accelerator sensor out, number 2 VIOS_ACCEL_SENS_OUT_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2007 to 2023.

Average engine speed of all cylinders VIOS_AV_RPM_ALL_CYL

Pelican can show this parameter as the engine speed.

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2007 to 2023.

Cruise control speed VIOS_CRUISE_CTRL_SPD

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2007 to 2023.

Engine speed of cylinder 1 VIOS_RPM_CYL_1

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2007 to 2023.

Engine speed of cylinder 2 VIOS_RPM_CYL_2

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2007 to 2023.

Engine speed of cylinder 3 VIOS_RPM_CYL_3

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2007 to 2023.

Engine speed of cylinder 4 VIOS_RPM_CYL_4

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2007 to 2023.

Front left wheel acceleration VIOS_FL_WHEEL_ACCELERATION

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

In testing for 2007 to 2023.

Front left wheel speed? VIOS_FL_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Front right wheel acceleration VIOS_FR_WHEEL_ACCELERATION

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

In testing for 2007 to 2023.

Front right wheel speed? VIOS_FR_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

High voltage, target engine speed VIOS_HIGH_V_TGT_RPM

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2007 to 2023.

Minimum engine speed VIOS_MIN_RPM

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2007 to 2023.

Rear left wheel acceleration VIOS_RL_WHEEL_ACCELERATION

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

In testing for 2007 to 2023.

Rear left wheel speed? VIOS_RL_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Rear right wheel acceleration VIOS_RR_WHEEL_ACCELERATION

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

In testing for 2007 to 2023.

Rear right wheel speed? VIOS_RR_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Vehicle speed VIOS_VEHICLE_SPEED_7E0

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2007 to 2023.

Vehicle speed VIOS_VSS

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7B0 → 7B8
  • Every200 ms
  • Testing for 2007 to 2010, 2012 to 2023

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.35
Range
0 to 323.85 km/h
Unit
km/h

In testing for 2007 to 2010, 2012 to 2023. Supported for 2011.

Orientation

Deceleration VIOS_DECEL

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

In testing for 2007 to 2023.

Deceleration 2 VIOS_DECEL_2

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

In testing for 2007 to 2023.

Deceleration open VIOS_DECELERATION_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Yaw rate, error? VIOS_YAW_RATE_OPEN_ERROR

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Yaw rate, sensor 1 VIOS_YAW_1

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2007 to 2023.

Yaw rate, sensor 2 VIOS_YAW_2

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2007 to 2023.

Zero point of deceleration VIOS_ZP_DEC

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

In testing for 2007 to 2023.

Zero point of deceleration 2 VIOS_ZP_DEC2

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

In testing for 2007 to 2023.

Zero point of yaw rate VIOS_ZERO_POINT_OF_YAW_RATE

  • Service 21PID A1
  • Module7B0 → 7B8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2007 to 2023.

Zero point of yaw rate, degrees/sec VIOS_ZP_YAW

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2007 to 2023.

Tires

Brake assist status VIOS_BA_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Front left wheel ABS status VIOS_FL_WHEEL_ABS_CTRL

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Front left wheel vehicle stability control status VIOS_FL_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Front right wheel ABS status VIOS_FR_WHEEL_ABS_CTRL

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Front right wheel cylinder open VIOS_FR_WHEEL_CYLINDER_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2007 to 2023.

Front right wheel vehicle stability control status VIOS_FR_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Predictive brake assist status VIOS_PBA_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Rear left wheel ABS status VIOS_RL_WHEEL_ABS_CTRL

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Rear left wheel EBS status VIOS_RL_WHEEL_EBD_CTRL

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Rear left wheel vehicle stability control status VIOS_RL_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Rear right wheel ABS status VIOS_RR_WHEEL_ABS_CTRL

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Rear right wheel EBS status VIOS_RR_WHEEL_EBD_CTRL

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Rear right wheel vehicle stability control status VIOS_RR_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Traction control, engine status VIOS_TRC_TRAC__ENGINE_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Traction control, status VIOS_TRC_TRAC__CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2023.

Wheel cylinder pressure VIOS_WHEEL_CYLINDER_PRESSURE

  • Service 21PID 07
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

In testing for 2007 to 2023.

Transmission

Current gear VIOS_GEAR_V2

  • Service 21PID DA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2023.

Torque converter and TE1 on VIOS_TQ_CONV_TE1_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Transmission fluid temperature, variant 5 VIOS_ATF_T_V_5

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2007 to 2023.

Transmission fluid temperature, variant 8 VIOS_ATF_T_V_8

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2007 to 2023.

Transmission fluid temperature, variant 14 VIOS_ATF_T_V_14

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2007 to 2023.

Transmission fluid temperature, variant 21 VIOS_ATF_T_V_21

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2023.

Transmission oil pressure calibration, complete VIOS_TRANS_OIL_PRESS

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2007 to 2023.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.