Toyota Sequoia

Parameters

The Toyota Sequoia has 608 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage SEQUOIA_12V_V_V2Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 15EE
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.31448+0.0125
Range
0 to 80.2 V
Unit
V

0x28 = 40 → 40×0.31448+0.0125 = 12.5917 V

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

+BM voltage SEQUOIA_BM_V

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

1st turbocharger outlet pressure, control valve SEQUOIA_1ST_TRUBOCHARGER_P

  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

2nd turbocharger outlet pressure SEQUOIA_2ND_TRUBOCHARGER_OUTLET_P

  • Service 22DID 11AF
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

2nd turbocharger outlet pressure, control valve SEQUOIA_2ND_TRUBOCHARGER_P

  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

12V battery current SEQUOIA_12V_CConfirmed

  • Service 22DID 15F7
  • Module7D2 → 7DA
  • Every500 ms
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38.14710000−125
Range
-125 to 124 A
Unit
A

0x6BF0 = 27632 → 27632×38.14710000−125 = -19.59221 A

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

12V battery temperature SEQUOIA_12V_TConfirmed

  • Service 22DID 15F8
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x027D = 637 → 63710−40 = 23.7 °C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

12V battery voltage SEQUOIA_12V_V_V2Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 15EE
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.31448+0.0125
Range
0 to 80.2 V
Unit
V

0x28 = 40 → 40×0.31448+0.0125 = 12.5917 V

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

12V battery voltage before system main relay SEQUOIA_12V_BAT_V_BEFORE_SMRConfirmed

  • Service 22DID 107E
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×6150000+11.25
Range
0 to 11.56 V
Unit
V

0x23 = 35 → 35×6150000+11.25 = 11.2927 V

Confirmed for 2023. In testing for 2024 to 2026.

12V battery voltage smoothed SEQUOIA_12V_BAT_V_SMOOTHEDConfirmed

  • Service 22DID 1F42
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

0x30FB = 12539 → 125391000 = 12.539 V

Confirmed for 2023. In testing for 2024 to 2026.

Aux battery voltage SEQUOIA_AUX_BAT_VConfirmed

  • Service 22DID 1002
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×6150000
Range
0 to 79.95 V
Unit
V

0x23C0 = 9152 → 9152×6150000 = 11.16544 V

Confirmed for 2023. In testing for 2024 to 2026.

Aux. battery capacity after IG OFF SEQUOIA_AUX_BAT_CAP_AFTER_IG_OFF

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 Ah
Unit
Ah

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Aux. battery capacity after IG ON SEQUOIA_AUX_BAT_CAP_AFTER_IG_ON

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 Ah
Unit
Ah

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Auxiliary battery current SEQUOIA_AUXILIARY_BATConfirmed

  • Service 22DID 1802
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×252513107−12500
Range
-12500 to -12451 A
Unit
A

0x00 = 0 → 0×252513107−12500 = -12,500 A

Confirmed for 2023. In testing for 2024 to 2026.

Battery current SEQUOIA_BAT_CURRENT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5013107−125
Range
-125 to 124.9 A
Unit
A

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Battery current SEQUOIA_BAT_CURRENT_700

  • Service 22DID 15F7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4912850−125
Range
-125 to 124.9 A
Unit
A

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Battery status of full charge SEQUOIA_BAT_STAT_FULL_CHG

  • Service 22DID 15E5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2552
Range
0 to 32512.5 Ah
Unit
Ah

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Battery temperature SEQUOIA_BAT_T

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 6513.5 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Battery temperature SEQUOIA_BAT_T_700

  • Service 22DID 15F8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Battery temperature SEQUOIA_BAT_T_700_2

  • Service 22DID 1FF8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Battery voltage SEQUOIA_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1002
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12.20710000
Range
0 to 79 V
Unit
V

0x27EC = 10220 → 10220×12.20710000 = 12.475554 V

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Battery voltage SEQUOIA_BAT_VConfirmed

  • Service 21PID 13
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Battery voltage SEQUOIA_BATTERY_VOLTAGE_7E0Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 192 to 207 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x3393 = 13203 → 132031000 = 13.203 V

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Battery voltage SEQUOIA_BATTERY_VOLTAGE_7E0_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 200 to 215 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x35DD = 13789 → 137891000 = 13.789 V

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Charge contactor current SEQUOIA_SCC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.

Charging integrated current of aux. battery SEQUOIA_CHG_INTEGRATED

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Dark current of battery SEQUOIA_DARK_CURRENT_BAT

  • Service 22DID 15E7
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

DC-DC converter high side voltage SEQUOIA_DC_DC_CONV_HIGH_SIDE_V

  • Service 22DID 111E
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122070310000000
Range
0 to 7999 V
Unit
V

In testing for 2024 to 2026. Not supported for 2023.

DC-DC converter low side voltage SEQUOIA_DC_DC_CONV_LOW_SIDE_V

  • Service 22DID 111D
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×195325000
Range
0 to 19.92 V
Unit
V

In testing for 2024 to 2026. Not supported for 2023.

DC-DC converter, target voltage before charging SEQUOIA_DC_DC_CONV_TGT_V

  • Service 22DID 111F
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122070310000000
Range
0 to 7999 V
Unit
V

In testing for 2024 to 2026. Not supported for 2023.

Discharging integrated current of aux. battery SEQUOIA_DISCHARGING

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Distance since last battery cable disconnection SEQUOIA_DIST_SINCE_BAT_DISCConfirmed

  • Service 22DID 106C
  • Module700 → 708
  • Every30 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x1BED = 7149 → 7,149 km

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

HV battery charge voltage SEQUOIA_HVBAT_CHRG_V

  • Service 22DID 1609
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 V
Unit
V

In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

HV battery charge, maximum SEQUOIA_HVBAT_SOC_MAXConfirmed

  • Service 22DID 106C
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x55 = 85 → 852 = 42.5 %

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

HV battery charge, minimum SEQUOIA_HVBAT_SOC_MINConfirmed

  • Service 22DID 106C
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x4B = 75 → 752 = 37.5 %

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

HV battery current SEQUOIA_HVBAT_CConfirmed

Pelican can show this parameter as the traction battery current.

  • Service 22DID 1F9A
  • Module7D2 → 7DA
  • Every500 ms
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

0x05FC = 1532 → 153210 = 153.2 A

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

HV battery maximum temperature SEQUOIA_HVBAT_MAX_T

  • Service 22DID 1829
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

HV battery minimum temperature SEQUOIA_HVBAT_MIN_T

  • Service 22DID 182A
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

HV battery voltage SEQUOIA_HVBAT_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 1F9A
  • Module7D2 → 7DA
  • Every500 ms
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×156.2510000
Range
0 to 1023 V
Unit
V

0x4140 = 16704 → 16704×156.2510000 = 261 V

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Hybrid battery 1 fan SEQUOIA_HYBRID_BAT_1_FANConfirmed

  • Service 22DID 1802
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2023. In testing for 2024 to 2026.

Hybrid battery temperature 1 SEQUOIA_HYBRID_BAT_T_1Confirmed

  • Service 22DID 1814
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×45865535−58
Range
-58 to 400 °F
Unit
°F

0x4AA1 = 19105 → 19105×45865535−58 = 75.517815 °F

Confirmed for 2023. In testing for 2024 to 2026.

Hybrid battery temperature 2 SEQUOIA_HYBRID_BAT_T_2Confirmed

  • Service 22DID 1814
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×95−58
Range
-58 to 401 °F
Unit
°F

0x4B = 75 → 75×95−58 = 77 °F

Confirmed for 2023. In testing for 2024 to 2026.

Hybrid battery temperature 3 SEQUOIA_HYBRID_BAT_T_3Confirmed

  • Service 22DID 1814
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×45865535−58
Range
-58 to 400 °F
Unit
°F

0x4B5E = 19294 → 19294×45865535−58 = 76.838666 °F

Confirmed for 2023. In testing for 2024 to 2026.

Initial engine battery voltage lower limit SEQUOIA_INITIAL_ENG_BAT_V_LO

  • Service 22DID 15F6
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Main connector solenoid current SEQUOIA_SMC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.

Main relay a, solenoid current SEQUOIA_SLA_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.

Main relay r solenoid current SEQUOIA_SLR_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.

Output speed sensor voltage SEQUOIA_NOUT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Regenerative braking cooperation SEQUOIA_REGEN_COOPERATION

  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.

Regenerative operation SEQUOIA_FR_REGEN_OPERATION

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.

Regenerative request SEQUOIA_FR_REGEN_REQUEST

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.

Relay control solenoid current SEQUOIA_SRC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.

Service contactor solenoid current SEQUOIA_SSC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.

Sleep time of battery sensor SEQUOIA_SLEEP_TIME_BATSENS

  • Service 22DID 15F0
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 h
Unit
h

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

State of charge SEQUOIA_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 1F5B
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x5A = 90 → 90×100255 = 35.294118 %

Confirmed for 2023 to 2025. In testing for 2026.

Turbine speed sensor voltage SEQUOIA_NT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Vh-voltage after boosting SEQUOIA_VH_V_AFTER_BOOSTINGConfirmed

  • Service 22DID 10B0
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 16 to 31 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 V
Unit
V

0x023E = 574 → 5742 = 287 V

Confirmed for 2023. In testing for 2024 to 2026.

Vl-voltage before boosting SEQUOIA_VL_V_BEFORE_BOOSTINGConfirmed

  • Service 22DID 10B0
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 V
Unit
V

0x023E = 574 → 5742 = 287 V

Confirmed for 2023. In testing for 2024 to 2026.

Voltage of battery sensor SEQUOIA_V_BATSENS

  • Service 22DID 15EE
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333310922500
Range
0 to 79.9979 V
Unit
V

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Climate

Adjusted ambient temperature SEQUOIA_ADJUSTED_AMBIENT_TConfirmed

  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×81.6255−30.8
Range
-30.8 to 50.8 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Air inlet damper actual pulse SEQUOIA_AIR_INLET_DAMPER_ACTUAL_PULSE

  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2013, 2018, 2020. Not supported for 2006, 2023 to 2025.

Air inlet damper target pulse SEQUOIA_AIR_INLET_DAMPER_TARGET_PULSEConfirmed

  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.

Air outlet servo actual pulse, driver SEQUOIA_AIR_OUTLET_SERVO_ACTU_PULSE_D

  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2013, 2018, 2020. Not supported for 2006, 2023 to 2025.

Air outlet servo pulse, driver SEQUOIA_AIR_OUTLET_SERVO_PULSE_DConfirmed

  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2011. Supported for 2023, 2025.

Ambient air temperature SEQUOIA_AAT_7C4Confirmed

  • Service 21PID 22
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255−23.3
Range
-23.3 to 65.95 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Ambient temperature SEQUOIA_AMBIENT_TConfirmed

  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x2F = 47 → 47−40 = 7 °C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Blower motor speed level SEQUOIA_BLOWER_MOTOR_SPEED_LEVELConfirmed

  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Cabin temperature SEQUOIA_CABIN_TConfirmed

  • Service 21PID 21
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×63.75255−6.5
Range
-6.5 to 57.25 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Communication with air conditioner SEQUOIA_COMM_WITH_AIR_CONDITIONERConfirmed

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2005, 2007 to 2026

Example reply from a 2006 Toyota Sequoia.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2006. In testing for 2000 to 2005, 2007, 2026. Not supported for 2013, 2018, 2020, 2023 to 2025.

Communication with HV SEQUOIA_COMMUNICATION_WITH_HVConfirmed

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2005, 2007 to 2026

Example reply from a 2006 Toyota Sequoia.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2006. In testing for 2000 to 2005, 2007, 2026. Not supported for 2013, 2018, 2020, 2023 to 2025.

Communication with valvematic SEQUOIA_COMM_WITH_VALVEMATIC_COMMConfirmed

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2005, 2007 to 2026

Example reply from a 2006 Toyota Sequoia.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2006. In testing for 2000 to 2005, 2007, 2026. Not supported for 2013, 2018, 2020, 2023 to 2025.

Evaporator fin thermistor SEQUOIA_EVAP_FIN_THERMISTORConfirmed

  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255−29.7
Range
-29.7 to 59.55 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Evaporator target temperature SEQUOIA_EVAP_TARGET_T

  • Service 21PID 4C
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327.68 to 327.67
Unit
Number

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Set temperature, driver side SEQUOIA_T_DRIVERConfirmed

  • Service 21PID 29
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Solar sensor, driver side SEQUOIA_SOLAR_DRIVERConfirmed

  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2026

Example reply from a 2013 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x09 = 9 → 9

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2018, 2020, 2023 to 2025.

Control

A/C compressor SEQUOIA_A_C_COMPRESSORConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Example reply from a 2013 Toyota Sequoia.

Bit 64 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2020. Not supported for 2006, 2018, 2023 to 2025.

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2006. Supported for 2005, 2007, 2011, 2013, 2020, 2023 to 2025.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2006. Supported for 2023.

Accelerator pedal SEQUOIA_ACCEL_PEDALConfirmed

  • Service 22DID 1059
  • Module700 → 708
  • Every250 ms
  • Testing for 2000 to 2022, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val1.42−28.873
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Accelerator pedal, position 1 SEQUOIA_ACC_PEDAL_POS_1

  • Service 22DID 1F49
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020, 2023 to 2025.

Accelerator pedal, position 2 SEQUOIA_ACC_PEDAL_POS_2

  • Service 22DID 1F4A
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020, 2023 to 2025.

Accelerator sensor voltage, 1 SEQUOIA_ACCEL_SENS_1_VOLTConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 128 to 135 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x29 = 41 → 41×100255 = 16.078431 %

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Accelerator sensor voltage, 1 SEQUOIA_ACCEL_SENS_1_VOLT_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 136 to 143 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x29 = 41 → 41×100255 = 16.078431 %

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Accelerator sensor voltage, 2 SEQUOIA_ACCEL_SENS_2_VOLTConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 136 to 143 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x51 = 81 → 81×100255 = 31.764706 %

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Accelerator sensor voltage, 2 SEQUOIA_ACCEL_SENS_2_VOLT_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 144 to 151 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x51 = 81 → 81×100255 = 31.764706 %

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Anti-lock brake warning light SEQUOIA_ABS_WARNConfirmed

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Brake warning light SEQUOIA_BRAKE_WARNConfirmed

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Buzzer SEQUOIA_BUZZERConfirmed

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Communication with brake SEQUOIA_COMMUNICATION_WITH_BRAKEConfirmed

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2005, 2007 to 2026

Example reply from a 2006 Toyota Sequoia.

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2006. In testing for 2000 to 2005, 2007, 2026. Not supported for 2013, 2018, 2020, 2023 to 2025.

Cruise control live brake cancel SEQUOIA_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCHConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Electrical load signal 1 SEQUOIA_ELECTRICAL_LOAD_SIGNAL_1Confirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Electrical load signal 2 SEQUOIA_ELECTRICAL_LOAD_SIGNAL_2Confirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Electronically controlled brake warning light SEQUOIA_ECB_WARNConfirmed

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Ignition trigger count SEQUOIA_IGNITION_TRIG_CNTConfirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Key remind sound SEQUOIA_KEY_REMIND_SOUNDConfirmed

  • Service 21PID A1
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Main idle SEQUOIA_MAIN_IDLE_SWConfirmed

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Neutral position SEQUOIA_NEUTRAL_POSITION_SW_SIGNALConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Parking brake SEQUOIA_PARKING_BRAKEConfirmed

  • Service 21PID 62
  • Module7D0 → 7D8
  • Every1 s
  • Testing for 2000 to 2019, 2021 to 2026

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2023 to 2025.

Parking brake SEQUOIA_PARKING_BRAKE_SWConfirmed

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Pattern switch SEQUOIA_PATTERN_SWITCH_PWR_MConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Power steering SEQUOIA_POWER_STEERING_SIGNALConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Relative throttle position TP_RSAE J1979Confirmed

Relative or 'learned' throttle position.

  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2006. Supported for 2023 to 2025.

Reservoir warning SEQUOIA_RESERVOIR_WARNING_SWConfirmed

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Shift SW status, drive SEQUOIA_SHIFT_SW_STATUS_D_RANGEConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Shift SW status, neutral SEQUOIA_SHIFT_SW_STATUS_N_RANGEConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Shift SW status, parking SEQUOIA_SHIFT_SW_STATUS_P_RANGEConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Shift SW status, reverse SEQUOIA_SHIFT_SW_STATUS_R_RANGEConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Slip indicator light SEQUOIA_SLIP_WARNConfirmed

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Sports mode selection SEQUOIA_SPORTS_MODE_SELECTION_SWConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Sports shift down SEQUOIA_SPORTS_SHIFT_DOWN_SWConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Sports shift up SEQUOIA_SPORTS_SHIFT_UP_SWConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Starter control SEQUOIA_STARTER_CONTROLConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Starter signal SEQUOIA_STARTER_SIGNALConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Steering angle SEQUOIA_STEERING_ANGLEConfirmed

  • Service 22DID 1004
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1.5
Range
-410 to 410 °
Unit
°

0x0000 = 0 → 0×1.5 = 0 °

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Steering wheel angle SEQUOIA_STEER_ANGLEConfirmed

Positive = counter-clockwise, negative = clockwise.

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2006, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 24 to 39 of the reply, 16 bits.

Formula
val10−3276.8
Range
-3276 to 3276 °
Unit
°

Confirmed for 2011, 2013, 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2007. Not supported for 2006, 2023 to 2025.

TC SEQUOIA_TC_TERMINALConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 61 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Traction control, brake status SEQUOIA_TRC_TRAC__BRAKE_CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2006. Supported for 2023.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2006. Supported for 2023.

Cruise control

Cruise control speed SEQUOIA_CC_SConfirmed

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2026

Example reply from a 2013 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2006 to 2007, 2011, 2013. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2018, 2020, 2023 to 2025.

Details

Inspection mode SEQUOIA_INSPECTION_MODEConfirmed

  • Service 21PID A6
  • Module7B0 → 7B8
  • Every60 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

DTCs

2nd air monitor available? SEQUOIA_2ND_AIR_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

2nd air monitor incomplete? SEQUOIA_2ND_AIR_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

A/C monitor available? SEQUOIA_A_C_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

A/C monitor incomplete? SEQUOIA_A_C_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Catalyst monitor available? SEQUOIA_CATALYST_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Catalyst monitor incomplete? SEQUOIA_CATALYST_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Complete parts monitor available? SEQUOIA_COMPLETE_PARTS_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2006 to 2007, 2011, 2013, 2023. Supported for 2005, 2020, 2024 to 2025.

EGR/VVT monitor available? SEQUOIA_EGR_VVT_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

EGR/VVT monitor incomplete? SEQUOIA_EGR_VVT_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

EVAP monitor available? SEQUOIA_EVAP_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

EVAP monitor_icmpl SEQUOIA_EVAP_MONITOR_ICMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Fuel system monitor available? SEQUOIA_FUEL_SYSTEM_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Heated catalyst monitor available? SEQUOIA_HEATED_CATALYST_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Heated catalyst monitor incomplete? SEQUOIA_HEATED_CATALYST_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

MIL SEQUOIA_MILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2006, 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

MIL ON run distance SEQUOIA_MILON_RUN_DISTANCEConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Misfire monitor available? SEQUOIA_MISFIRE_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Number of emission DTC SEQUOIA_NUMBER_OF_EMISSION_DTCConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2006, 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

O2S heater monitor available? SEQUOIA_O2S_A_FS_HEATER_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

O2S heater monitor incomplete? SEQUOIA_O2S_A_FS_HEATER_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

O2S monitor available? SEQUOIA_O2S_A_FS_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

O2S monitor incomplete? SEQUOIA_O2S_A_FS_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Running time from MIL ON SEQUOIA_RUNNING_TIME_FROM_MIL_ONConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

ECU

VVT-ie duty ratio bank 1 SEQUOIA_VVT_IE_DUTY_RATIO_1

  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 14 of the reply, 15 bits.

Formula
val×399.965535−200
Range
-200 to -0.0531 %
Unit
%

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

VVT-ie motor direction: forward bank 1 SEQUOIA_VVT_IE_MOTOR_DIRECTION_FORWARD_1

  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Electrical

B+ battery voltage SEQUOIA_BATTERY_VOLTAGE_7C0Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1021
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 20 V
Unit
V

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2013, 2018, 2020.

Engine

A/F heater duty bank 1 sensor 1 SEQUOIA_F_HEATER_DUTY_B1S1

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

A/F ratio learn value high, bank 1 SEQUOIA_AF_LEARN_HIGH_PORT_B1Confirmed

  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

0x8E = 142 → 142×100255−50 = 5.686275 %

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

A/F ratio learn value idle, bank 1 SEQUOIA_AF_LEARN_IDLE_PORT_B1Confirmed

  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

A/F ratio learn value low, bank 1 SEQUOIA_AF_LEARN_LOW_PORT_B1Confirmed

  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

A/F ratio learn value mid.1, bank 1 SEQUOIA_AF_LEARN_MID1_PORT_B1Confirmed

  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

0x9A = 154 → 154×100255−50 = 10.392157 %

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

A/F ratio learn value mid.2, bank 1 SEQUOIA_AF_LEARN_MID2_PORT_B1Confirmed

  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

0x8D = 141 → 141×100255−50 = 5.294118 %

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

A/F ratio learned high, bank 1 SEQUOIA_A_F_RATIO_LEARNED_HIGH_BANK_1Confirmed

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

0x8A = 138 → 138×100255−50 = 4.117647 %

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

A/F ratio learned idle, bank 1 SEQUOIA_A_F_RATIO_LEARNED_IDLE_BANK_1Confirmed

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

A/F ratio learned low, bank 1 SEQUOIA_A_F_RATIO_LEARNED_LOW_BANK_1Confirmed

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

0x7C = 124 → 124×100255−50 = -1.372549 %

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

A/F ratio learned mid 1, bank 1 SEQUOIA_A_F_RATIO_LEARNED_MID_1_BANK_1Confirmed

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

0x7C = 124 → 124×100255−50 = -1.372549 %

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

A/F ratio learned mid 2, bank 1 SEQUOIA_A_F_RATIO_LEARNED_MID_2_BANK_1Confirmed

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

0x8C = 140 → 140×100255−50 = 4.901961 %

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

A/F test results 1, incomplete SEQUOIA_F_TEST_RESULTS_1

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Accessory relay on SEQUOIA_ACC_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Accumulator open SEQUOIA_ACCUMULATOR_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2018, 2020. Not supported for 2006, 2013, 2023 to 2025.

Acoustic control induction system vacuum switching valve on SEQUOIA_ACIS_VSV_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Actual engine torque SEQUOIA_ACT_ENG_TQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Actuator power supply on SEQUOIA_ACTUATOR_POWER_SUP_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 146 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Air conditioning compressor SEQUOIA_AC_COMP

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Air conditioning power consumption SEQUOIA_AC_POWER_CONSConfirmed

  • Service 22DID 106E
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 kW
Unit
kW

0x00 = 0 → 020 = 0 kW

Confirmed for 2023. In testing for 2024 to 2026.

Air mix servo target pulse, driver SEQUOIA_AIR_MIX_SERVO_TARG_D

  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Air mix servo, actual pulse, d SEQUOIA_AIR_MIX_SERVO_ACT_D

  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Air-fuel equivalence ratio, bank 1 sensor 1 SEQUOIA_AF_LAMBDA_B1S1Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Air-fuel sensor current, bank 1 sensor 1 SEQUOIA_AFS_I_B1S1Confirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 96 to 111 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.99 mA
Unit
mA

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Air-fuel sensor voltage, bank 1 sensor 1 SEQUOIA_AFS_V_B1S1Confirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 32 to 47 of the reply, 16 bits.

Formula
val×7.9965535
Range
0 to 7.99 V
Unit
V

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Alt voltage - active test SEQUOIA_ALT_VOL_ACTIVE_TEST

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Alt voltage - non active test SEQUOIA_ALT_VOL_NON_ACTIVE

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Alternator output duty SEQUOIA_ALTERNATOR_OUTPUT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Alternator output duty cycle SEQUOIA_ALT_DUTY_CYCLE

  • Service 22DID 15FA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val164
Range
0 to 399 %
Unit
%

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Ambient temperature SEQUOIA_AAT_7D2Confirmed

  • Service 22DID 1F46
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Atmospheric pressure SEQUOIA_ATMOSPHERE_PRESSUREConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

0x62 = 98 → 98 kPa

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Atmospheric pressure SEQUOIA_ATMOSPHERE_PRESSURE_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

0x63 = 99 → 99 kPa

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Automatic transmission fluid thermal degradation estimate SEQUOIA_ATF_THERMAL_DEGRAD_ESTConfirmed

  • Service 22DID 162B
  • Module701 → 709
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0096 = 150 → 150

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2006, 2013, 2023. Supported for 2005, 2007, 2011, 2020, 2024 to 2025.

Calculated load SEQUOIA_CALCULATED_LOAD_7E0Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x3F = 63 → 63×100255 = 24.705882 %

Confirmed for 2006, 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016.

Calculated load SEQUOIA_CALCULATED_LOAD_7E0_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x34 = 52 → 52×100255 = 20.392157 %

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Catalyst temperature bank 2 sensor 1 SEQUOIA_CAT_T_BANK_2_SENS_1Confirmed

  • Service 22DID 1F3D
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2024, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

0x19A2 = 6562 → 6562×950−40 = 1,141.16 °F

Confirmed for 2023, 2025. In testing for 2000 to 2022, 2024, 2026.

Catalyst temperature bank 2 sensor 2 SEQUOIA_CAT_T_BANK_2_SENS_2Confirmed

  • Service 22DID 1F3F
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2024, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

0x1650 = 5712 → 5712×950−40 = 988.16 °F

Confirmed for 2023, 2025. In testing for 2000 to 2022, 2024, 2026.

Catalyst temperature, bank 1 sensor 1 SEQUOIA_CAT_T_B1S1Confirmed

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2023 to 2025.

Catalyst temperature, bank 1 sensor 2 SEQUOIA_CAT_T_B1S2Confirmed

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 48 to 63 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2023 to 2025.

Catalyst temperature, bank 1 sensor 2, variant 2 SEQUOIA_CAT_T_B1S2_V2

  • Service 21PID 3E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Check mode on SEQUOIA_CHECK_MODE_ON

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Closed throttle position switch on SEQUOIA_CLOSED_THROTTLE_POS_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 125 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Codes, include history SEQUOIA_CODES_INCLUDE

  • Service 21PID E1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2006, 2013, 2023. Supported for 2024 to 2025.

Continuously variable transmission learning complete SEQUOIA_CVT_LEARNED

  • Service 21PID DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Continuously variable transmission oil pressure SEQUOIA_CVT_OIL_P

  • Service 21PID BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200 kPa
Unit
kPa

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Coolant temperature SEQUOIA_COOL_TConfirmed

  • Service 22DID 1F05
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x51 = 81 → 81−40 = 41 °C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Coolant temperature SEQUOIA_COOLANT_TEMP_7E0Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x82 = 130 → 130−40 = 90 °C

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Coolant temperature SEQUOIA_COOLANT_TEMP_7E0_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x82 = 130 → 130−40 = 90 °C

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Coolant water route switching valve 1, closed? SEQUOIA_COOLANT_VALVE_1_CLOSE

  • Service 22DID 282C
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Coolant water route switching valve 2, closed? SEQUOIA_COOLANT_VALVE_2_CLOSE

  • Service 22DID 2847
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Cooling fan duty ratio SEQUOIA_COOLING_FAN_DUTY_RATIOConfirmed

  • Service 22DID 1046
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×127.5255
Range
0 to 127.5 %
Unit
%

0x00 = 0 → 0×127.5255 = 0 %

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Cruise control on SEQUOIA_CRUISE_CTRL_ON

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Cylinder 1 injection volume SEQUOIA_CYL_1_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Cylinder 2 injection volume SEQUOIA_CYL_2_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Cylinder 3 injection volume SEQUOIA_CYL_3_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Cylinder 4 injection volume SEQUOIA_CYL_4_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Cylinder number SEQUOIA_CYLINDER_NUMBER

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Destination SEQUOIA_DESTINATION

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Dist battery cable disconnect SEQUOIA_DIST_BATT_CABLE

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Electric fan motor on SEQUOIA_ELEC_FAN_MOTOR_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Electric thermostat duty ratio SEQUOIA_ELECTRIC_THERMOSTAT_DUTY_RATIO

  • Service 22DID 2829
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Electric water pump SEQUOIA_ELECTRIC_WATER_PUMP

  • Service 22DID 2827
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200 rpm
Unit
rpm

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Electric water pump RPM SEQUOIA_EWP_RPM

  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Electric water pump target speed SEQUOIA_EWP_TARGET_VSS

  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Engine coolant temperature SEQUOIA_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 26
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255+1.3
Range
1.3 to 90.55 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Engine coolant temperature SEQUOIA_ECT_7C0Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 23
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Engine coolant temperature, at ignition SEQUOIA_ECT_IGNConfirmed

  • Service 22DID 1041
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×62.5100−40
Range
-40 to 119.375 °C
Unit
°C

0x75 = 117 → 117×62.5100−40 = 33.125 °C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Engine coolant temperature, initial SEQUOIA_ECT_INITConfirmed

  • Service 22DID 1041
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×62.5100−40
Range
-40 to 119.375 °C
Unit
°C

0x76 = 118 → 118×62.5100−40 = 33.75 °C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Engine independent SEQUOIA_ENG_INDEPENDENT

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 91 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Engine independent control SEQUOIA_ENG_INDEPENDENT_CTRL

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Engine oil pressure SEQUOIA_EOPConfirmed

  • Service 22DID 1074
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10128
Range
0 to 5119.92 kPa
Unit
kPa

0x0000 = 0 → 0×10128 = 0 kPa

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Engine oil pressure control valve SEQUOIA_EOP_CONTROL_VALVE

  • Service 22DID 2848
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0762939
Range
0 to 4999.9207 mA
Unit
mA

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Engine oil temperature SEQUOIA_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2023 to 2025.

Engine oil temperature SEQUOIA_EOT_700Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 107B
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 192 to 199 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x47 = 71 → 71−40 = 31 °C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Engine oil temperature, variation 2 SEQUOIA_EOT_V2Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1F5C
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x4A = 74 → 74−40 = 34 °C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Engine run time SEQUOIA_ENGINE_RUN_TIMEConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 88 to 103 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x0444 = 1092 → 1,092 s

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Engine run time SEQUOIA_ENGINE_RUN_TIME_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x07D0 = 2000 → 2,000 s

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Engine run time, up to 255 sec. only SEQUOIA_ENG_RUN_TIME_UP_255

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Engine speed SEQUOIA_ENGINE_SPEED_7E0Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 64 to 79 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0AE3 = 2787 → 27874 = 696.75 rpm

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Engine speed SEQUOIA_ENGINE_SPEED_7E0_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0DA2 = 3490 → 34904 = 872.5 rpm

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Engine stall control FB flow SEQUOIA_ENG_STALL_CTRL_FB

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096−40
Range
-40 to 39.99
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Evaporative purge duty SEQUOIA_EVAP_PURGE_DUTY_7E0

  • Service 21PID 2E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Evaporative purge flow SEQUOIA_EVAP_PURGE_FLOW

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.99 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Evaporative purge vacuum switching valve on SEQUOIA_EVAP_PURGE_VSV_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Exhaust gas recirculation step position SEQUOIA_EGR_STEP_POSITIONConfirmed

  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2006, 2008 to 2026

Example reply from a 2007 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x84 = 132 → 132

Confirmed for 2007. In testing for 2000 to 2006, 2008 to 2022, 2024 to 2026. Not supported for 2023.

Exhaust gas recirculation temperature SEQUOIA_EGR_T

  • Service 21PID ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5385
Range
0 to 159 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Exhaust gas recirculation valve step SEQUOIA_EGR_STEP

  • Service 21PID E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Exhaust VVT change angle, bank 1 SEQUOIA_EXHAUST_VVT_ANGLE_B1Confirmed

  • Service 22DID 1088
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

0x0000 = 0 → 0×639.965535 = 0 °

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Exhaust VVT hold learn value, bank 1 SEQUOIA_EXHAUST_VVT_HOLD_LEARN_B1Confirmed

  • Service 22DID 1089
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×399.965535
Range
0 to 399.9 %
Unit
%

0x1E67 = 7783 → 7783×399.965535 = 47.492511 %

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Exhaust VVT oil control valve control duty SEQUOIA_EXHAUST_VVT_OCV_CONTROL_DUTYConfirmed

  • Service 22DID 1062
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×40065535
Range
0 to 400 %
Unit
%

0x0082 = 130 → 130×40065535 = 0.793469 %

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Exhaust VVT target angle B1 SEQUOIA_EXHAUST_VVT_TARGET_ANGLE_B1Confirmed

  • Service 22DID 1071
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

0x0000 = 0 → 0×639.965535 = 0 °

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Exhaust VVT timing most over-advanced learn value, bank 1 SEQUOIA_EXHAUST_VVT_OVER_ADV_LEARN_B1Confirmed

  • Service 22DID 108F
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.9965535
Range
0 to 639.99 °
Unit
°

0x2FB1 = 12209 → 12209×639.9965535 = 119.228472 °

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Front/rear motor torque ratio SEQUOIA_FRONT_REAR_MOTOR_TQConfirmed

  • Service 22DID 1039
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.76 to 32.76
Unit
Number

0x0988 = 2440 → 24401000−32.768 = -30.328

Confirmed for 2023. In testing for 2024 to 2026.

Fuel cut for engine stop request SEQUOIA_F_C_ENG_STOP_REQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 92 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Fuel cut TAU on SEQUOIA_FC_TAU_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Fuel filter temperature SEQUOIA_FFT

  • Service 22DID 109A
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

G sensor calibration, complete SEQUOIA_G_SENS_CALIBRATION

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

G sensor learning value SEQUOIA_G_SENS_LEARNING

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Generator inverter temperature SEQUOIA_GEN_INVERTER_T

  • Service 22DID 10A4
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026. Not supported for 2023.

Generator inverter temperature SEQUOIA_GEN_INVERTER_T_7D2

  • Service 22DID 10A8
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026. Not supported for 2023.

Generator inverter temperature after ignition on SEQUOIA_GEN_INVERTER_T_AFTER_ON

  • Service 22DID 10A8
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026. Not supported for 2023.

Glass humidity SEQUOIA_GLASS_HUMIDITY

  • Service 21PID B1
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Glass temperature SEQUOIA_GLASS_T

  • Service 21PID AF
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9500−557.8
Range
-557 to 621 °F
Unit
°F

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Hydraulic valve, communication open SEQUOIA_HV_COMM_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2018, 2020. Not supported for 2006, 2013, 2023 to 2025.

Idle control SEQUOIA_IDLE_CTRL

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Idle spark advance control 1 SEQUOIA_IDLE_SPARK_ADVN_CTRL_1

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Idle spark advance control 2 SEQUOIA_IDLE_SPARK_ADVN_CTRL_2

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Idle spark advance control 3 SEQUOIA_IDLE_SPARK_ADVN_CTRL_3

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Idle spark advance control 4 SEQUOIA_IDLE_SPARK_ADVN_CTRL_4

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Idle spark advance control, cylinder 1 SEQUOIA_IDLE_SAC_CYL_1

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Idle spark advance control, cylinder 2 SEQUOIA_IDLE_SAC_CYL_2

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Idle spark advance control, cylinder 3 SEQUOIA_IDLE_SAC_CYL_3

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Idle spark advance control, cylinder 4 SEQUOIA_IDLE_SAC_CYL_4

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Idle speed control learning SEQUOIA_IDLE_SPD_CTRL

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 93 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Idle speed control learning value, l/s SEQUOIA_IDLE_SPD_CTRL_L_S

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val×0.0012206912
Range
0 to 79.99
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

IG OFF elapsed time SEQUOIA_IG_OFF_ELAPSED_TIME

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 min
Unit
min

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Ignition advance SEQUOIA_SPARKADV_21

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Ignition timing advance SEQUOIA_IGN_ADVANCEConfirmed

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 48 to 55 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Immobilizer communication on SEQUOIA_IMMOBILIZER_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 120 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Initial engine coolant temperature SEQUOIA_INITIAL_ECT

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×531850−40
Range
-40 to 119.3
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Initial intake air temperature SEQUOIA_INITIAL_IAT

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Injection SEQUOIA_INJECTIONConfirmed

  • Service 22DID 1019
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x01 = 1 → DIRECT

States
Raw valueStateMeaning
1DIRECTDirect
2BOTHBoth

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Injection duration for cylinder 1 SEQUOIA_INJ_DUR_CYL_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Injection feedback value 1 SEQUOIA_INJ_FEEDBACK_1

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 1 SEQUOIA_INJ_FEEDBACK_1_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 2 SEQUOIA_INJ_FEEDBACK_2

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 2 SEQUOIA_INJ_FEEDBACK_2_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 3 SEQUOIA_INJ_FEEDBACK_3

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 3 SEQUOIA_INJ_FEEDBACK_3_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 4 SEQUOIA_INJ_FEEDBACK_4

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 4 SEQUOIA_INJ_FEEDBACK_4_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 5 SEQUOIA_INJ_FEEDBACK_5

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 6 SEQUOIA_INJ_FEEDBACK_6

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume SEQUOIA_INJ_VOLConfirmed

  • Service 22DID 1017
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val3200
Range
0 to 20 L
Unit
L

0x0000 = 0 → 03200 = 0 L

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Injection volume - target SEQUOIA_INJ_VOLUME_TGT

  • Service 22DID 112C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000
Range
0 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume 1 SEQUOIA_INJ_VOLUME_1

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume 2 SEQUOIA_INJ_VOLUME_2

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume 3 SEQUOIA_INJ_VOLUME_3

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume 5 SEQUOIA_INJ_VOLUME_5

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume 6 SEQUOIA_INJ_VOLUME_6

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume per 10 injections, cylinder 1 SEQUOIA_INJ_VOL_CYL_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32000000
Range
0 to 0.002 L
Unit
L

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Injection volume total SEQUOIA_INJ_VOLUME_TOT

  • Service 22DID 112F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injector port SEQUOIA_INJECTOR_PORTConfirmed

  • Service 22DID 1018
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

0x0000 = 0 → 01000 = 0 ms

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Injector pulse width SEQUOIA_INJ_PW

  • Service 21PID E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1631275
Range
0 to 32.6 ms
Unit
ms

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Injector pulse width SEQUOIA_INJ_WIDTH

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Input shaft speed SEQUOIA_SPD_NIN

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Intake air temperature SEQUOIA_IAT_21

  • Service 21PID 0F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Intake air temperature SEQUOIA_INTAKE_AIR_7E0_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x2D = 45 → 45−40 = 5 °C

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Intake air temperature, bank 1 sensor 1 SEQUOIA_IAT_B1S1Confirmed

  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2024, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3A = 58 → 58−40 = 18 °C

Confirmed for 2023, 2025. In testing for 2000 to 2022, 2024, 2026.

Intake air temperature, bank 1 sensor 2 SEQUOIA_IAT_B1S2

  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2024, 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Supported for 2023, 2025.

Intake VVT change angle, bank 1 SEQUOIA_INTAKE_VVT_CHANGE_ANGLE_BANK_1Confirmed

  • Service 22DID 1087
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

0x0000 = 0 → 0×639.965535 = 0 °

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Intake VVT most over-retarded learn value, bank 1 SEQUOIA_INTAKE_VVT_OVER_RET_LEARN_B1Confirmed

  • Service 22DID 108D
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.9965535
Range
0 to 639.99 °
Unit
°

0x0CFF = 3327 → 3327×639.9965535 = 32.490222 °

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Intake VVT target angle B1 SEQUOIA_INTAKE_VVT_TARGET_ANGLE_B1Confirmed

  • Service 22DID 106F
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

0x0000 = 0 → 0×639.965535 = 0 °

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Integrated engine run time SEQUOIA_INTEGRATED_ENG_RUN

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Intercooler coolant temperature SEQUOIA_INTERCOOLER_ECT

  • Service 22DID 119C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Intercooler water pump SEQUOIA_INTERCOOLER_WATERConfirmed

  • Service 22DID 2820
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2024, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8013107
Range
0 to 300 %
Unit
%

0x0000 = 0 → 0×8013107 = 0 %

Confirmed for 2023, 2025. In testing for 2000 to 2022, 2024, 2026.

Internal temperature SEQUOIA_ECU_INTERNAL_TConfirmed

  • Service 22DID 105E
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x37 = 55 → 55−40 = 15 °C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Inverter coolant temperature SEQUOIA_INVRT_COOLANT_TConfirmed

  • Service 22DID 10B2
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
0 to 100 °C
Unit
°C

0x33 = 51 → 51−40 = 11 °C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Inverter water pump duty SEQUOIA_INVERTER_WATER_PMP

  • Service 22DID 1112
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×152595000000
Range
0 to 199 %
Unit
%

In testing for 2024 to 2026. Not supported for 2023.

Judge time engine ignition SEQUOIA_JUDGE_TIME_ENG_IGN

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Judge time engine output SEQUOIA_JUDGE_TIME_ENG

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Key cycle SEQUOIA_KEY_CYCLEConfirmed

  • Service 22DID 0102
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x2494 = 9364 → 9,364

Confirmed for 2023. In testing for 2024 to 2026.

Knock adjust SEQUOIA_KNOCK_ADJUST

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Knock adjust SEQUOIA_KNOCK_ADJUST_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Knock correct learn value SEQUOIA_KNOCK_CORRECT_LEARN

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val32−1024
Range
-1024 to 1023 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Knock correction, learned value SEQUOIA_KNOCK_CORRECT_LEARNED_VALUEConfirmed

  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×312.510000−1024
Range
-1024 to 1023
Unit
Number

0x81DE = 33246 → 33246×312.510000−1024 = 14.9375

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Knock feedback SEQUOIA_KNOCK_FEEDBACK

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Knock feedback SEQUOIA_KNOCK_FEEDBACK_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Knock feedback value SEQUOIA_KNOCK_FEEDBACK_VALUEConfirmed

  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×312.510000−1024
Range
-1024 to 1023
Unit
Number

0x7FA0 = 32672 → 32672×312.510000−1024 = -3

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Lock up state SEQUOIA_LOCK_UP_STATEConfirmed

  • Service 22DID 1620
  • Module701 → 709
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Long term fuel trim, bank 1 SEQUOIA_LONG_FT_B1Confirmed

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.21 %
Unit
%

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Long term fuel trim, bank 2 SEQUOIA_LONG_FT_B2Confirmed

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.21 %
Unit
%

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Long-term fuel trim, bank 1 SEQUOIA_LTFT1_21

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.7809803922−100
Range
-100 to 99.15 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Manifold absolute pressure SEQUOIA_MAP_7E0Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

0x6A = 106 → 106 kPa

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Manifold absolute pressure SEQUOIA_MAP_7E0_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

0x2D = 45 → 45 kPa

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Mass air flow SEQUOIA_MAF_21

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 g/s
Unit
g/s

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Mass air flow SEQUOIA_MAF_7E0Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 24 to 39 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

0x01F2 = 498 → 498100 = 4.98 g/s

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Mass air flow SEQUOIA_MAF_7E0_V2Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 24 to 39 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

0x0214 = 532 → 532100 = 5.32 g/s

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Master cylinder open SEQUOIA_MASTER_CYLINDER_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2013, 2023 to 2025.

Master cylinder sensor temperature SEQUOIA_MASTER_CYL_TEMPConfirmed

  • Service 22DID 1006
  • Module7B0 → 7B8
  • Every5 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−80
Range
-20 to 100 °C
Unit
°C

0x5A = 90 → 90−80 = 10 °C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2013, 2018, 2020.

Maximum generator inverter temperature SEQUOIA_MAX_GEN_INVERTER_T

  • Service 22DID 10A8
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026. Not supported for 2023.

Maximum motor inverter temperature SEQUOIA_MAX_MOTOR_INVERTER_TConfirmed

  • Service 22DID 10A5
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x63 = 99 → 99−40 = 59 °C

Confirmed for 2023. In testing for 2024 to 2026.

Misfire count, all cylinders SEQUOIA_MISFIRE_CNTConfirmed

  • Service 22DID 10A5
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Misfire count, cylinder 1 SEQUOIA_MISFIRE_CYL1

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Misfire count, cylinder 2 SEQUOIA_MISFIRE_CYL2

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Misfire count, cylinder 3 SEQUOIA_MISFIRE_CYL3

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Misfire count, cylinder 4 SEQUOIA_MISFIRE_CYL4

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Misfire load SEQUOIA_MISFIRE_LOADConfirmed

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×510255
Range
0 to 510 %
Unit
%

0x00 = 0 → 0×510255 = 0 %

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Misfire margin SEQUOIA_MISFIRE_MARGIN

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 rpm
Unit
rpm

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2023 to 2025. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Misfire RPM SEQUOIA_MISFIRE_RPM

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val×6375255
Range
0 to 6375 rpm
Unit
rpm

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2023 to 2025. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Misfire RPM SEQUOIA_MISFIRE_RPM_7E0Confirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Misfire test result, incomplete SEQUOIA_MIS_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Model year SEQUOIA_MODEL_YEAR

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val+1900
Range
1900 to 2155
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Motor inverter temperature SEQUOIA_MOTOR_INVERTER_TConfirmed

  • Service 22DID 10A5
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x45 = 69 → 69−40 = 29 °C

Confirmed for 2023. In testing for 2024 to 2026.

Motor inverter temperature after ignition on SEQUOIA_MOTOR_INVERTER_T_ONConfirmed

  • Service 22DID 10A5
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x4C = 76 → 76−40 = 36 °C

Confirmed for 2023. In testing for 2024 to 2026.

Motor inverter, maximum temperature SEQUOIA_M_INVRT_MAX_T

  • Service 22DID 10A6
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020, 2023 to 2025.

Motor regenerative brake torque SEQUOIA_MOTOR_REGENERATIVE_BREAKConfirmed

  • Service 22DID 1069
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 16 to 31 of the reply, 16 bits.

Formula
val8−4096
Range
-4096 to 4095 kW
Unit
kW

0x8000 = 32768 → 327688−4096 = 0 kW

Confirmed for 2023. In testing for 2024 to 2026.

Motor regenerative brake torque, requested SEQUOIA_MOTOR_REGENERATIVEConfirmed

  • Service 22DID 1069
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−4096
Range
-4096 to 4095 kW
Unit
kW

0x8000 = 32768 → 327688−4096 = 0 kW

Confirmed for 2023. In testing for 2024 to 2026.

Motor RPM SEQUOIA_RPM_7D2Confirmed

  • Service 22DID 10A1
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767 rpm
Unit
rpm

0x7FFE = 32766 → 32766−32768 = -2 rpm

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Motor torque SEQUOIA_TQConfirmed

  • Service 22DID 10A1
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 48 to 63 of the reply, 16 bits.

Formula
val8−4096
Range
-4096 to 4095 N·m
Unit
N·m

0x8002 = 32770 → 327708−4096 = 0.25 N·m

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

O2 heater b1s2_active SEQUOIA_O2_HEATER_B1S2

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 68 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

O2 heater current val bank 1 sensor 2 SEQUOIA_O2_HEATER_CURR_VAL

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 A
Unit
A

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Open side malfunction on SEQUOIA_OPEN_SIDE_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 145 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Output shaft speed SEQUOIA_SPD_NOUT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

OXS1, A/FS2 test result, incomplete SEQUOIA_OXS1_FS2_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Oxygen sensor voltage, bank 1 sensor 1 SEQUOIA_O2S11_V

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.0049960784
Range
0 to 1.27 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Oxygen sensor voltage, bank 1 sensor 2 SEQUOIA_O2S_B1S2Confirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 144 to 151 of the reply, 8 bits.

Formula
val×51000
Range
0 to 1.275 V
Unit
V

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

PM accumulation ratio - bank 1 SEQUOIA_PM_ACCUMULATION_RAT_1

  • Service 22DID 1105
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 15 %
Unit
%

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Purge cut vacuum switching valve duty SEQUOIA_PURGE_CUT_VSV_DUTY

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Racing operation SEQUOIA_RACING_OPERATION

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 90 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Rear motor inverter, coolant temperature SEQUOIA_RM_INVRT_COOL_T

  • Service 22DID 10A6
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020, 2023 to 2025.

Rear motor regenerative brake torque SEQUOIA_REAR_MOTOR_REGENERATIVE

  • Service 22DID 106A
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val8−4096
Range
-4096 to 4095 kW
Unit
kW

In testing for 2024 to 2026. Not supported for 2023.

Rear motor regenerative brake torque, requested SEQUOIA_REAR_MOTOR

  • Service 22DID 106A
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−4096
Range
-4096 to 4095 kW
Unit
kW

In testing for 2024 to 2026. Not supported for 2023.

Rear motor speed SEQUOIA_RM_TQ_REQ

  • Service 22DID 10A2
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020, 2023 to 2025.

Rear motor torque SEQUOIA_RM_TQ

  • Service 22DID 10A2
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val8−4096
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020, 2023 to 2025.

Regulator pressure SEQUOIA_REGULATOR_PConfirmed

  • Service 21PID 53
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×37510525500−456.68
Range
-456.68 to 3294 kPa
Unit
kPa

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Request engine run time SEQUOIA_REQ_ENG_RUN_TIME

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Request warm-up SEQUOIA_REQ_WARM_UP

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 89 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Requested engine torque SEQUOIA_REQ_ENG_TQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Rough idle, cylinder 1 SEQUOIA_ROUGH_IDLE_CYL_1Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

0x01 = 1 → 1 °

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Rough idle, cylinder 2 SEQUOIA_ROUGH_IDLE_CYL_2Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

0x00 = 0 → 0 °

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Rough idle, cylinder 3 SEQUOIA_ROUGH_IDLE_CYL_3Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

0x3F = 63 → 63 °

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Rough idle, cylinder 4 SEQUOIA_ROUGH_IDLE_CYL_4Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

0x00 = 0 → 0 °

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Short term fuel trim, bank 1 SEQUOIA_SHORT_FT_B1Confirmed

Pelican can show this parameter as the short term fuel trim.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.21 %
Unit
%

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Short term fuel trim, bank 2 SEQUOIA_SHORT_FT_B2Confirmed

Pelican can show this parameter as the short term fuel trim.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.21 %
Unit
%

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Starter relay on SEQUOIA_STARTER_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Stroke open SEQUOIA_STROKE_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2013, 2023 to 2025.

Synchronize stroke sensor position SEQUOIA_SYNCHRONIZE_STROKE

  • Service 22DID 1634
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25665535
Range
0 to 256 mm
Unit
mm

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

System guard on SEQUOIA_SYSTEM_GUARD_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 144 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle fully close learn SEQUOIA_THROTTLE_FULLY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle idle position on SEQUOIA_THROTTLE_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 149 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle motor current SEQUOIA_THROTTLE_MOTOR

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×564
Range
0 to 19.9 A
Unit
A

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle motor duty SEQUOIA_THROTTLE_MOTOR_DUTYConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 144 to 151 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x29 = 41 → 41×100255 = 16.078431 %

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Throttle motor duty SEQUOIA_THROTTLE_MOTOR_DUTY_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 152 to 159 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x29 = 41 → 41×100255 = 16.078431 %

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Throttle motor duty, close SEQUOIA_THROTTLE_MOTOR_DUTY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle motor duty, open SEQUOIA_THROTTLE_MOTOR_DUTY_OPEN

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle position SEQUOIA_THROTTLE_21

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle position command SEQUOIA_THROTTLE_POS_COMMAND

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle position, number 1 SEQUOIA_THROTTLE_POS_NUMBER_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle position, number 2 SEQUOIA_THROTTLE_POS_NUMBER_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle require position SEQUOIA_THROTTLE_REQUIRE_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle sensor open position 1 SEQUOIA_THROTTLE_SENS_OPEN_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle sensor open position 2 SEQUOIA_THROTTLE_SENS_OPEN_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle sensor position SEQUOIA_THROTTLE_SENSOR_POSITIONConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 104 to 111 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Throttle sensor position SEQUOIA_THROTTLE_SENSOR_POSITION_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 112 to 119 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Throttle sensor voltage, 1 SEQUOIA_THROTTLE_SENSOR_VOLTConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 112 to 119 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x29 = 41 → 41×100255 = 16.078431 %

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Throttle sensor voltage, 1 SEQUOIA_THROTTLE_SENSOR_VOLT_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x29 = 41 → 41×100255 = 16.078431 %

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Throttle sensor voltage, 2 SEQUOIA_THROTTLE_SENSOR_2_VOLTConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x7A = 122 → 122×100255 = 47.843137 %

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Throttle sensor voltage, 2 SEQUOIA_THROTTLE_SENSOR_2_VOLT_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 128 to 135 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x7A = 122 → 122×100255 = 47.843137 %

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Time since DTCs cleared SEQUOIA_TIME_SINCE_DTC_CLEAREDConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

0x006F = 111 → 111 min

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Time since DTCs cleared SEQUOIA_TIME_SINCE_DTC_CLEARED_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 184 to 199 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

0x1147 = 4423 → 4,423 min

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Total fuel trim, bank 1 SEQUOIA_TOT_FT_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100256−50
Range
-50 to 49.6 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Transaxle oil temperature SEQUOIA_TRANSAXLE_OIL_TConfirmed

  • Service 22DID 1040
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x86 = 134 → 134−40 = 94 °C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Transmission fluid pan temperature SEQUOIA_TF1_PANConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1627
  • Module701 → 709
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.00703125−40
Range
-40 to 350 °F
Unit
°F

0x4A00 = 18944 → 18944×0.00703125−40 = 93.2 °F

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Transmission fluid post-converter temperature SEQUOIA_TF2_CONV

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1628
  • Module701 → 709
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.00703125−40
Range
-40 to 350 °F
Unit
°F

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Transmission fluid temperature SEQUOIA_ATF_TEMP_700

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1638
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2011, 2013, 2018, 2020, 2023 to 2025.

Transmission output shaft speed SEQUOIA_TRANS_OUT_RPM

  • Service 21PID BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Turbine speed SEQUOIA_SPD_NT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Valvematic current angle SEQUOIA_VALVEMATIC_CURRENT

  • Service 21PID 31
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Valvematic, target angle SEQUOIA_VALVEMATIC_TGT_ANG

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Variable valve timing aim angle 1 SEQUOIA_VARIABLE_VLV_TIM_AIM_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333218450
Range
0 to 399 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Variable valve timing change angle 1 SEQUOIA_VARIABLE_VLV_TIM_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.0097642481
Range
0 to 639 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Variable valve timing control status 1 on SEQUOIA_VARIABLE_VLV_TIM_1_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Variable valve timing oil control valve duty 1 SEQUOIA_VARIABLE_VLV_TIM_OIL_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0061020829
Range
0 to 399 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Variable valve timing oil temperature SEQUOIA_VVTOTConfirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2023 to 2025.

Variable valve timing opening angle bank 1 SEQUOIA_VVT_IE_OPENING_ANGLE_BANK_1

  • Service 22DID 2843
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Vehicle speed SEQUOIA_VSS_21

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Vehicle speed sensor test result, incomplete SEQUOIA_SPD_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Warm-up cycles since DTCs cleared SEQUOIA_WARMUP_CYCLES_DTC_CLEAREDConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Warm-up cycles since DTCs cleared SEQUOIA_WARMUP_CYCLES_DTC_CLEARED_V2Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x15 = 21 → 21

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Catalyst

Catalyst temperature, bank 1 sensor 1 SEQUOIA_CAT_T_11Confirmed

  • Service 22DID 1F3C
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x0305 = 773 → 77310−40 = 37.3 °C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Catalyst temperature, bank 1 sensor 2 SEQUOIA_CAT_T_12Confirmed

  • Service 22DID 1F3E
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x02D9 = 729 → 72910−40 = 32.9 °C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Misfires

All cylinders misfire count SEQUOIA_ALL_CYLINDERS_MISFIRE_CNTConfirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Cylinder #1 misfire count SEQUOIA_CYL1_MISFIRE_CNTConfirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Cylinder #2 misfire count SEQUOIA_CYL2_MISFIRE_CNTConfirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Cylinder #3 misfire count SEQUOIA_CYL3_MISFIRE_CNTConfirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Cylinder #4 misfire count SEQUOIA_CYL4_MISFIRE_CNTConfirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Misfire load SEQUOIA_MISFIRE_LOAD_7E0Confirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val×4256
Range
0 to 3.98
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Misfire margin SEQUOIA_MISFIRE_MARGIN_7E0Confirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 %
Unit
%

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2023. Supported for 2006 to 2007, 2013, 2020, 2024 to 2025.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2023. Supported for 2006 to 2007, 2013, 2020, 2024 to 2025.

Fluids

Distance since oil change SEQUOIA_OIL_CHANGE_ODOConfirmed

  • Service 21PID 41
  • Module7C0 → 7C8
  • Every30 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×251460015625
Range
0 to 41038.272 km
Unit
km

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Fuel

Engine fuel rate SEQUOIA_ENG_FUEL_RATE

  • Service 22DID F19D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel cut SEQUOIA_FUEL_CUT

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Fuel cut SEQUOIA_FUEL_CUT_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 121 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Fuel cut time SEQUOIA_FUEL_CUT_TIME

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×537512
Range
0 to 68734.9511
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Fuel injection timing SEQUOIA_FUEL_INJ_TIM

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Fuel level SEQUOIA_FLI

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 1F2F
  • Module700 → 708
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Fuel level SEQUOIA_FUEL_LEVELConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 1022
  • Module7C0 → 7C8
  • Every30 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

0x0000 = 0 → 0100 = 0 L

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2013, 2018, 2020.

Fuel level, volume SEQUOIA_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 21PID 29
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2000 to 2010, 2012, 2014 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5003785
Range
0 to 21 gal
Unit
gal

Confirmed for 2011, 2013. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006 to 2007, 2018, 2020, 2023 to 2025.

Fuel pressure 1 SEQUOIA_FUEL_P_1

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel pressure 1 SEQUOIA_FUEL_P_1_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel pressure 2 SEQUOIA_FUEL_P_2

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel pressure 2 SEQUOIA_FUEL_P_2_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel pressure 3 SEQUOIA_FUEL_P_3

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel pressure 3 SEQUOIA_FUEL_P_3_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel pressure 4 SEQUOIA_FUEL_P_4

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel pressure 4 SEQUOIA_FUEL_P_4_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel pressure 5 SEQUOIA_FUEL_P_5

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel pressure 6 SEQUOIA_FUEL_P_6

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel pump duty ratio SEQUOIA_FUEL_PUMP_DUTY_RATIOConfirmed

  • Service 22DID 106A
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0609756098
Range
0 to 3996 kPa
Unit
kPa

0x0000 = 0 → 0×0.0609756098 = 0 kPa

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Fuel pump/speed status on SEQUOIA_FUEL_PMP_SPD_STAT_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Fuel return temperature SEQUOIA_FUEL_RETURN_T

  • Service 22DID 1141
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel temperature 1 SEQUOIA_FUEL_T_1

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel temperature 1 SEQUOIA_FUEL_T_1_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel temperature 2 SEQUOIA_FUEL_T_2

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel temperature 2 SEQUOIA_FUEL_T_2_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel temperature 3 SEQUOIA_FUEL_T_3

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel temperature 3 SEQUOIA_FUEL_T_3_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel temperature 4 SEQUOIA_FUEL_T_4

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel temperature 4 SEQUOIA_FUEL_T_4_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel temperature 5 SEQUOIA_FUEL_T_5

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Fuel temperature 6 SEQUOIA_FUEL_T_6

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

High fuel pressure, actual SEQUOIA_HFP_ACTUALConfirmed

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x013A = 314 → 314×10 = 3,140 kPa

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

High fuel pressure, target SEQUOIA_HFP_TARGETConfirmed

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0190 = 400 → 400×10 = 4,000 kPa

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Low fuel pressure SEQUOIA_LFPConfirmed

  • Service 22DID 10CD
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.8
Range
0 to 3276.7 kPa
Unit
kPa

0x8DE6 = 36326 → 3632610−3276.8 = 355.8 kPa

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Low fuel pressure SEQUOIA_LOW_FUEL_PRESSUREConfirmed

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0026 = 38 → 38×10 = 380 kPa

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Target air-fuel equivalence ratio SEQUOIA_LAMBDA_TARGETConfirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Vehicle fuel rate SEQUOIA_VEH_FUEL_RATE

  • Service 22DID F19D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Lights

Check engine SW SEQUOIA_CHECK_ENGINE_LIGHTConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2013. Not supported for 2006, 2023 to 2025.

Hazard switch history SEQUOIA_HAZARD_SWITCH_HISTORYConfirmed

  • Service 21PID BC
  • Module7B0 → 7B8
  • Every3600 s
  • Testing for 2000 to 2019, 2021 to 2026

Bit 2 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0INCOMPLETEIncomplete
1COMPLETEComplete

Confirmed for 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022. Not supported for 2006, 2013, 2023.

Oil pressure switch SEQUOIA_EOP_LIGHTConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2013. Not supported for 2006, 2023 to 2025.

P-seatbelt buckle SW SEQUOIA_P_SEATBELT_BUCKLE_LIGHTConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2013. Not supported for 2006, 2023 to 2025.

Rheostat SEQUOIA_RHEOSTATConfirmed

Higher values are brighter

  • Service 21PID 68
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2026

Example reply from a 2013 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFC = 252 → 252

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022. Not supported for 2006, 2020, 2023 to 2025.

Stop light SEQUOIA_STOP_LIGHT_SWConfirmed

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Stop light SEQUOIA_STOP_LIGHT_SWITCHConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2018, 2023 to 2025.

Stop light relay SEQUOIA_STOP_LIGHT_RELAYConfirmed

  • Service 21PID 3C
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2013, 2023 to 2025.

Tail cancel SW SEQUOIA_TAIL_CANCEL_LIGHTConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Movement

Accelerator fully close learn 1 SEQUOIA_ACCEL_FULLY_CLOSE_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Accelerator fully close learn 2 SEQUOIA_ACCEL_FULLY_CLOSE_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Accelerator idle position on SEQUOIA_ACCEL_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 148 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Accelerator position SEQUOIA_ACCEL_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Accelerator sensor out, number 1 SEQUOIA_ACCEL_SENS_OUT_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Accelerator sensor out, number 2 SEQUOIA_ACCEL_SENS_OUT_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Average engine speed of all cylinders SEQUOIA_AV_RPM_ALL_CYL

Pelican can show this parameter as the engine speed.

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Compressor speed SEQUOIA_COMP_SPD

  • Service 21PID 49
  • Module7C4 → 7CC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Compressor, target speed SEQUOIA_COMP_TGT_SPD

  • Service 21PID 4A
  • Module7C4 → 7CC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Cruise control speed SEQUOIA_CRUISE_CTRL_SPD

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Engine speed of cylinder 1 SEQUOIA_RPM_CYL_1

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Engine speed of cylinder 2 SEQUOIA_RPM_CYL_2

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Engine speed of cylinder 3 SEQUOIA_RPM_CYL_3

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Engine speed of cylinder 4 SEQUOIA_RPM_CYL_4

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Front left wheel acceleration SEQUOIA_FL_WHEEL_ACCELERATIONConfirmed

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Front left wheel speed SEQUOIA_FL_WHEEL_VSSConfirmed

  • Service 22DID 1075
  • Module7D2 → 7DA
  • Every100 ms
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 31 of the reply, 16 bits.

Formula
val100−327.68
Range
-327.68 to 327.67 km/h
Unit
km/h

0x8000 = 32768 → 32768100−327.68 = 0 km/h

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Front left wheel speed SEQUOIA_TIRE_FL_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2006, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

Confirmed for 2011, 2013, 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2007. Not supported for 2006, 2023 to 2025.

Front left wheel speed? SEQUOIA_FL_WHEEL_SPEED_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2013, 2023 to 2025.

Front right wheel acceleration SEQUOIA_FR_WHEEL_ACCELERATIONConfirmed

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Front right wheel speed SEQUOIA_FR_WHEEL_VSSConfirmed

  • Service 22DID 1075
  • Module7D2 → 7DA
  • Every100 ms
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327.68 to 327.67 km/h
Unit
km/h

0x8000 = 32768 → 32768100−327.68 = 0 km/h

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Front right wheel speed SEQUOIA_TIRE_FR_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2006, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

Confirmed for 2011, 2013, 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2007. Not supported for 2006, 2023 to 2025.

Front right wheel speed? SEQUOIA_FR_WHEEL_SPEED_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2013, 2023 to 2025.

High voltage, target engine speed SEQUOIA_HIGH_V_TGT_RPM

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Intercooler water pump speed, raw count SEQUOIA_IWP_SPEEDConfirmed

  • Service 22DID 1075
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x80CD = 32973 → 32,973

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Minimum engine speed SEQUOIA_MIN_RPM

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

NC1 speed SEQUOIA_NC1_SPD

  • Service 22DID 1614
  • Module701 → 709
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 10000 rpm
Unit
rpm

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

NO speed SEQUOIA_NO_SPD

  • Service 22DID 1618
  • Module701 → 709
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 10000 rpm
Unit
rpm

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

NT speed SEQUOIA_NT_SPD

  • Service 22DID 161A
  • Module701 → 709
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 10000 rpm
Unit
rpm

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Rear left wheel acceleration SEQUOIA_RL_WHEEL_ACCELERATIONConfirmed

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 24 to 31 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Rear left wheel speed SEQUOIA_RL_WHEEL_VSSConfirmed

  • Service 22DID 1075
  • Module7D2 → 7DA
  • Every100 ms
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 48 to 63 of the reply, 16 bits.

Formula
val100−327.68
Range
-327.68 to 327.67 km/h
Unit
km/h

0x8000 = 32768 → 32768100−327.68 = 0 km/h

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Rear left wheel speed SEQUOIA_TIRE_RL_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2006, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

Confirmed for 2011, 2013, 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2007. Not supported for 2006, 2023 to 2025.

Rear left wheel speed? SEQUOIA_RL_WHEEL_SPEED_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2013, 2023 to 2025.

Rear right wheel acceleration SEQUOIA_RR_WHEEL_ACCELERATIONConfirmed

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 16 to 23 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Rear right wheel speed SEQUOIA_RR_WHEEL_VSSConfirmed

  • Service 22DID 1075
  • Module7D2 → 7DA
  • Every100 ms
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 32 to 47 of the reply, 16 bits.

Formula
val100−327.68
Range
-327.68 to 327.67 km/h
Unit
km/h

0x8000 = 32768 → 32768100−327.68 = 0 km/h

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Rear right wheel speed SEQUOIA_TIRE_RR_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2006, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

Confirmed for 2011, 2013, 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2007. Not supported for 2006, 2023 to 2025.

Rear right wheel speed? SEQUOIA_RR_WHEEL_SPEED_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2013, 2023 to 2025.

Secondary speed SEQUOIA_NSS_SPD

  • Service 22DID 1616
  • Module701 → 709
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 10000 rpm
Unit
rpm

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Speed SEQUOIA_VSS_7C0Confirmed

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7C0 → 7C8
  • Every250 ms
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Vehicle speed SEQUOIA_VEHICLE_SPEED_7E0Confirmed

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Vehicle speed SEQUOIA_VEHICLE_SPEED_7E0_V2Confirmed

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x23 = 35 → 35 km/h

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Vehicle speed SEQUOIA_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7B0 → 7B8
  • Every200 ms
  • Testing for 2000 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.35
Range
0 to 323.85 km/h
Unit
km/h

Confirmed for 2011, 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Vehicle speed SEQUOIA_VSS_V2Confirmed

Pelican can show this parameter as the speed.

  • Service 22DID 1F0D
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Orientation

Deceleration SEQUOIA_DECELConfirmed

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Deceleration 2 SEQUOIA_DECEL_2Confirmed

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Deceleration open SEQUOIA_DECELERATION_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2013, 2023 to 2025.

Lateral g SEQUOIA_LAT_GConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2006, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.5 to 2.5 g
Unit
g

Confirmed for 2011, 2013, 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2007. Not supported for 2006, 2023 to 2025.

Longitudinal g SEQUOIA_LNG_GConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2006, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.5 to 2.5 g
Unit
g

Confirmed for 2011, 2013, 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2007. Not supported for 2006, 2023 to 2025.

Yaw rate value, degrees/sec SEQUOIA_YAW_RATEConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2006, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

Confirmed for 2011, 2013, 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2007. Not supported for 2006, 2023 to 2025.

Yaw rate, error? SEQUOIA_YAW_RATE_OPEN_ERRORConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2013, 2023 to 2025.

Yaw rate, sensor 1 SEQUOIA_YAW_1Confirmed

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Yaw rate, sensor 2 SEQUOIA_YAW_2Confirmed

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Zero point of deceleration SEQUOIA_ZP_DECConfirmed

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Zero point of deceleration 2 SEQUOIA_ZP_DEC2Confirmed

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Zero point of yaw rate SEQUOIA_ZERO_POINT_OF_YAW_RATE

  • Service 21PID A1
  • Module7B0 → 7B8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.

Zero point of yaw rate, degrees/sec SEQUOIA_ZP_YAWConfirmed

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Seatbelts

Buckle switch, left side SEQUOIA_BUCKLE_LS

  • Service 21PID 04
  • Module780 → 788
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2018, 2020. Not supported for 2006, 2013, 2023 to 2025.

Buckle switch, right side SEQUOIA_BUCKLE_RSConfirmed

  • Service 21PID 04
  • Module780 → 788
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2023 to 2025.

Reverse beep SEQUOIA_REVERSE_BEEP

  • Service 21PID AC
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
On or off

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.

Seat belt beep, driver SEQUOIA_SEAT_BELT_BEEP_DRIVERConfirmed

  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Seat belt beep, passenger SEQUOIA_SEAT_BELT_BEEP_PASSENGERConfirmed

  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Seat belt beep, reminder SEQUOIA_SEAT_BELT_BEEP_REMINDERConfirmed

  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Tires

Brake assist status SEQUOIA_BA_CTRL_STATUSConfirmed

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Front left tire pressure SEQUOIA_TP_3Confirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 1005
  • Module750 → 758
  • Every15 s
  • Testing for 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val4.125−5.6969697
Range
0 to 56.1212 psi
Unit
psi

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Front left tire pressure SEQUOIA_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing for 2000 to 2006, 2008 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2011, 2013, 2023 to 2025.

Front left tire temperature SEQUOIA_TT_3Confirmed

  • Service 22DID 1004
  • Module750 → 758
  • Every15 s
  • Testing for 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-30 to 100 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Front left tire temperature SEQUOIA_TT_FLConfirmed

Pelican can show this parameter as the front left tire temperature.

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing for 2000 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x39 = 57 → 57−40 = 17 °C

Confirmed for 2018. In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2011, 2013, 2020, 2023 to 2025.

Front left wheel ABS status SEQUOIA_FL_WHEEL_ABS_CTRLConfirmed

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Front left wheel vehicle stability control status SEQUOIA_FL_WHEEL_VSC_CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Front right tire pressure SEQUOIA_TP_1Confirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 1005
  • Module750 → 758
  • Every15 s
  • Testing for 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val4.125−5.6969697
Range
0 to 56.1212 psi
Unit
psi

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Front right tire pressure SEQUOIA_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing for 2000 to 2006, 2008 to 2017, 2019, 2021 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2011, 2013, 2023 to 2025.

Front right tire temperature SEQUOIA_TT_1Confirmed

  • Service 22DID 1004
  • Module750 → 758
  • Every15 s
  • Testing for 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-30 to 100 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Front right tire temperature SEQUOIA_TT_FRConfirmed

Pelican can show this parameter as the front right tire temperature.

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing for 2000 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3A = 58 → 58−40 = 18 °C

Confirmed for 2018. In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2011, 2013, 2020, 2023 to 2025.

Front right wheel ABS status SEQUOIA_FR_WHEEL_ABS_CTRLConfirmed

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Front right wheel cylinder open SEQUOIA_FR_WHEEL_CYLINDER_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2013, 2023 to 2025.

Front right wheel vehicle stability control status SEQUOIA_FR_WHEEL_VSC_CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Predictive brake assist status SEQUOIA_PBA_CTRL_STATUSConfirmed

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Rear left tire pressure SEQUOIA_TP_4Confirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 1005
  • Module750 → 758
  • Every15 s
  • Testing for 2026

Bits 56 to 63 of the reply, 8 bits.

Formula
val4.125−5.6969697
Range
0 to 56.1212 psi
Unit
psi

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Rear left tire pressure SEQUOIA_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing for 2000 to 2006, 2008 to 2017, 2019, 2021 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2011, 2013, 2023 to 2025.

Rear left tire temperature SEQUOIA_TT_4Confirmed

  • Service 22DID 1004
  • Module750 → 758
  • Every15 s
  • Testing for 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-30 to 100 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Rear left tire temperature SEQUOIA_TT_RLConfirmed

Pelican can show this parameter as the rear left tire temperature.

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing for 2000 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x38 = 56 → 56−40 = 16 °C

Confirmed for 2018. In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2011, 2013, 2020, 2023 to 2025.

Rear left wheel ABS status SEQUOIA_RL_WHEEL_ABS_CTRLConfirmed

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Rear left wheel EBS status SEQUOIA_RL_WHEEL_EBD_CTRLConfirmed

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Rear left wheel vehicle stability control status SEQUOIA_RL_WHEEL_VSC_CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Rear right tire pressure SEQUOIA_TP_2Confirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 1005
  • Module750 → 758
  • Every15 s
  • Testing for 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val4.125−5.6969697
Range
0 to 56.1212 psi
Unit
psi

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Rear right tire pressure SEQUOIA_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing for 2000 to 2006, 2008 to 2017, 2019, 2021 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2011, 2013, 2023 to 2025.

Rear right tire temperature SEQUOIA_TT_2Confirmed

  • Service 22DID 1004
  • Module750 → 758
  • Every15 s
  • Testing for 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-30 to 100 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Rear right tire temperature SEQUOIA_TT_RRConfirmed

Pelican can show this parameter as the rear right tire temperature.

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing for 2000 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Sequoia.

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x38 = 56 → 56−40 = 16 °C

Confirmed for 2018. In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2011, 2013, 2020, 2023 to 2025.

Rear right wheel ABS status SEQUOIA_RR_WHEEL_ABS_CTRLConfirmed

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Rear right wheel EBS status SEQUOIA_RR_WHEEL_EBD_CTRLConfirmed

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Rear right wheel vehicle stability control status SEQUOIA_RR_WHEEL_VSC_CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Spare tire pressure SEQUOIA_TP_5Confirmed

  • Service 22DID 1005
  • Module750 → 758
  • Every15 s
  • Testing for 2026

Bits 72 to 79 of the reply, 8 bits.

Formula
val4.125−5.6969697
Range
0 to 56.1212 psi
Unit
psi

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Spare tire pressure SEQUOIA_TP_SPAREConfirmed

  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing for 2000 to 2006, 2008 to 2017, 2019, 2021 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2011, 2013, 2023 to 2025.

Spare tire temperature SEQUOIA_TT_5Confirmed

  • Service 22DID 1004
  • Module750 → 758
  • Every15 s
  • Testing for 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-30 to 100 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Spare tire temperature SEQUOIA_TT_SPARE

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing for 2000 to 2017, 2019 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022. Supported for 2018. Not supported for 2006, 2011, 2013, 2020, 2023 to 2025.

Tire 1 position SEQUOIA_TID_1Confirmed

  • Service 22DID 2021
  • Module750 → 758
  • Every86400 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x01 = 1 → FL

States
Raw valueStateMeaning
1FLFront left
2FRFront right
3RLRear left
4RRRear right

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Tire 2 position SEQUOIA_TID_2Confirmed

  • Service 22DID 2021
  • Module750 → 758
  • Every86400 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states

0x02 = 2 → FR

States
Raw valueStateMeaning
1FLFront left
2FRFront right
3RLRear left
4RRRear right

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Tire 3 position SEQUOIA_TID_3Confirmed

  • Service 22DID 2021
  • Module750 → 758
  • Every86400 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

Unit
Named states

0x03 = 3 → RL

States
Raw valueStateMeaning
1FLFront left
2FRFront right
3RLRear left
4RRRear right

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Tire 4 position SEQUOIA_TID_4Confirmed

  • Service 22DID 2021
  • Module750 → 758
  • Every86400 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 24 to 31 of the reply, 8 bits.

Unit
Named states

0x04 = 4 → RR

States
Raw valueStateMeaning
1FLFront left
2FRFront right
3RLRear left
4RRRear right

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Tire pressure 1, set 2 SEQUOIA_TIRE_P_1_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing for 2000 to 2006, 2008 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2000 to 2006, 2008 to 2010, 2012 to 2022, 2024, 2026. Not supported for 2011, 2023, 2025.

Tire pressure 2, set 2 SEQUOIA_TIRE_P_2_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing for 2000 to 2006, 2008 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2000 to 2006, 2008 to 2010, 2012 to 2022, 2024, 2026. Not supported for 2011, 2023, 2025.

Tire pressure 3, set 2 SEQUOIA_TIRE_P_3_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing for 2000 to 2006, 2008 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2000 to 2006, 2008 to 2010, 2012 to 2022, 2024, 2026. Not supported for 2011, 2023, 2025.

Tire pressure 4, set 2 SEQUOIA_TIRE_P_4_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing for 2000 to 2006, 2008 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2000 to 2006, 2008 to 2010, 2012 to 2022, 2024, 2026. Not supported for 2011, 2023, 2025.

Tire pressure 5, set 2 SEQUOIA_TIRE_P_5_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing for 2000 to 2006, 2008 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2000 to 2006, 2008 to 2010, 2012 to 2022, 2024, 2026. Not supported for 2011, 2023, 2025.

Traction control, engine status SEQUOIA_TRC_TRAC__ENGINE_CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Traction control, status SEQUOIA_TRC_TRAC__CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022. Not supported for 2006, 2023 to 2025.

Wheel cylinder pressure SEQUOIA_WHEEL_CYLINDER_PRESSURE

  • Service 21PID 07
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.

Transmission

Boosting converter temperature, lower SEQUOIA_BOOSTING_CONV_T_LO

  • Service 22DID 10A7
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026. Not supported for 2023.

Boosting converter temperature, upper SEQUOIA_BOOSTING_CONV_T_HI

  • Service 22DID 10A7
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026. Not supported for 2023.

Current gear SEQUOIA_GEAR_V2Confirmed

  • Service 21PID DA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2000 to 2005, 2007 to 2026

Example reply from a 2006 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2006. In testing for 2000 to 2005, 2007, 2026. Not supported for 2013, 2018, 2020, 2023 to 2025.

DC-DC converter output current SEQUOIA_DC_DC_CONV_OUTPUT

  • Service 22DID 111C
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532
Range
0 to 199 A
Unit
A

In testing for 2024 to 2026. Not supported for 2023.

Gear SEQUOIA_GEARConfirmed

  • Service 21PID 85
  • Module7E0 → 7E8
  • Every400 ms
  • Testing for 2000 to 2010, 2012, 2014 to 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 20
Unit
Number

Confirmed for 2011, 2013, 2020. In testing for 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2018, 2023 to 2025.

Gear SEQUOIA_GEAR_700Confirmed

  • Service 22DID 1621
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Lock up state SEQUOIA_AT_LOCK_UP_STATEConfirmed

  • Service 22DID 1620
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Torque converter and TE1 on SEQUOIA_TQ_CONV_TE1_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Torque converter lock-up SEQUOIA_TQC_LOCKUPConfirmed

Engages a clutch inside the torque converter to create a direct connection between the engine and transmission, reducing slippage and improving efficiency.

  • Service 21PID 85
  • Module7E0 → 7E8
  • Every400 ms
  • Testing for 2000 to 2010, 2012, 2014 to 2019, 2021 to 2026

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2011, 2013, 2020. In testing for 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2018, 2023 to 2025.

Transmission fluid post-converter temperature, variant 3 SEQUOIA_TRANS_FLUID_POST_T_3

  • Service 22DID 1628
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Transmission fluid temperature, pan var.3 SEQUOIA_ATF_T_PAN_V3Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1627
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

0x4880 = 18560 → 18560256−40 = 32.5 °C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Transmission fluid temperature, variant 5 SEQUOIA_ATF_T_V_5

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Transmission fluid temperature, variant 8 SEQUOIA_ATF_T_V_8

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Transmission fluid temperature, variant 14 SEQUOIA_ATF_T_V_14

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Transmission fluid temperature, variant 21 SEQUOIA_ATF_T_V_21

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Transmission oil pressure calibration, complete SEQUOIA_TRANS_OIL_PRESS

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Transmission shift state ratio SEQUOIA_TRANS_SHIFT_ST_RAT

  • Service 22DID 1622
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×533321845000
Range
0 to 15.999
Unit
Number

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Transmission shift state ratio SEQUOIA_TRANS_SHIFT_ST_RAT_701

  • Service 22DID 1622
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×533321845000
Range
0 to 15.999
Unit
Number

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Transmission temperature, pan SEQUOIA_ATF_PAN_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2011, 2013, 2018, 2020. In testing for 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2023 to 2025.

Transmission temperature, torque converter SEQUOIA_ATF_TQC_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2011, 2013, 2018, 2020. In testing for 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2023 to 2025.

Trips

Odometer SEQUOIA_ENG_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 0103
  • Module700 → 708
  • Every30 s
  • Testing for 2000 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x015F3D = 89917 → 89,917 km

Confirmed for 2023. In testing for 2000 to 2022, 2024 to 2026.

Odometer SEQUOIA_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 21PID 28
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2011 to 2019, 2021 to 2026

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2020. In testing for 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006 to 2007. Not supported for 2011, 2013, 2018, 2023 to 2025.

Odometer SEQUOIA_ODO_V2_V2Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 0103
  • Module7D2 → 7DA
  • Every10 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x000405 = 1029 → 1,029 km

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Odometer SEQUOIA_ODO_V5Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 0103
  • Module701 → 709
  • Every30 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x000405 = 1029 → 1,029 km

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Previous trip distance SEQUOIA_PREV_TRIP_DSTConfirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 40 to 55 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km
Unit
km

Confirmed for 2013, 2018, 2020. In testing for 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2023 to 2025.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.