Toyota Hilux

Parameters

The Toyota Hilux has 574 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage HILUX_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1002
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12.20710000
Range
0 to 15 V
Unit
V

0x2490 = 9360 → 9360×12.20710000 = 11.425752 V

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

+BM voltage HILUX_BM_V

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

1st turbocharger outlet pressure, control valve HILUX_1ST_TRUBOCHARGER_P

  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

2nd turbocharger outlet pressure HILUX_2ND_TRUBOCHARGER_OUTLET_P

  • Service 22DID 11AF
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

2nd turbocharger outlet pressure, control valve HILUX_2ND_TRUBOCHARGER_P

  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

AFS voltage B1S1 HILUX_AFS_VOLTAGE_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×7.9965535
Range
0 to 7.99 V
Unit
V

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Aux. battery capacity after IG OFF HILUX_AUX_BAT_CAP_AFTER_IG_OFF

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 Ah
Unit
Ah

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Aux. battery capacity after IG ON HILUX_AUX_BAT_CAP_AFTER_IG_ON

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 Ah
Unit
Ah

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Battery current HILUX_BAT_CURRENT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5013107−125
Range
-125 to 124.9 A
Unit
A

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Battery current HILUX_BAT_CURRENT_700

  • Service 22DID 15F7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4912850−125
Range
-125 to 124.9 A
Unit
A

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Battery status of full charge HILUX_BAT_STAT_FULL_CHG

  • Service 22DID 15E5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2552
Range
0 to 32512.5 Ah
Unit
Ah

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Battery temperature HILUX_BAT_T

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 6513.5 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Battery temperature HILUX_BAT_T_700

  • Service 22DID 15F8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Battery temperature HILUX_BAT_T_700_2

  • Service 22DID 1FF8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Battery voltage HILUX_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1002
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12.20710000
Range
0 to 15 V
Unit
V

0x2490 = 9360 → 9360×12.20710000 = 11.425752 V

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Battery voltage HILUX_BAT_VConfirmed

  • Service 21PID 13
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x79 = 121 → 12110 = 12.1 V

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Battery voltage HILUX_BATTERY_VOLTAGE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65.535 V
Unit
V

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Charge contactor current HILUX_SCC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Charging integrated current of aux. battery HILUX_CHG_INTEGRATED

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Dark current of battery HILUX_DARK_CURRENT_BAT

  • Service 22DID 15E7
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Discharging integrated current of aux. battery HILUX_DISCHARGING

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Distance since last battery cable disconnection HILUX_12V_DISCONNECT_ODOConfirmed

  • Service 22DID 106C
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x4649 = 17993 → 17,993 km

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Initial engine battery voltage lower limit HILUX_INITIAL_ENG_BAT_V_LO

  • Service 22DID 15F6
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Main connector solenoid current HILUX_SMC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Main relay a, solenoid current HILUX_SLA_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Main relay r solenoid current HILUX_SLR_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Output speed sensor voltage HILUX_NOUT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Regenerative braking cooperation HILUX_REGEN_COOPERATION

  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Regenerative operation HILUX_FR_REGEN_OPERATION

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Regenerative request HILUX_FR_REGEN_REQUEST

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Relay control solenoid current HILUX_SRC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Service contactor solenoid current HILUX_SSC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Sleep time of battery sensor HILUX_SLEEP_TIME_BATSENS

  • Service 22DID 15F0
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 h
Unit
h

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Turbine speed sensor voltage HILUX_NT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Voltage of battery sensor HILUX_V_BATSENS

  • Service 22DID 15EE
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333310922500
Range
0 to 79.9979 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Climate

Adjusted ambient temperature HILUX_ADJUSTED_AMBIENT_TConfirmed

  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×81.6255−30.8
Range
-30.8 to 50.8 °C
Unit
°C

0xA1 = 161 → 161×81.6255−30.8 = 20.72 °C

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Air conditioner feedback HILUX_AC_FB

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 216 to 231 of the reply, 16 bits.

Formula
val×108192−40
Range
-40 to 39.99
Unit
Number

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Air inlet damper actual pulse HILUX_AIR_INLET_DAMPER_ACTUAL_PULSEConfirmed

  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x82 = 130 → 130

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Air inlet damper target pulse HILUX_AIR_INLET_DAMPER_TARGET_PULSEConfirmed

  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x82 = 130 → 130

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Air outlet servo actu pulse, driver HILUX_AIR_OUTLET_SERVO_ACTU_PULSE_DConfirmed

  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x80 = 128 → 128

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2026. Not supported for 2025.

Air outlet servo pulse, driver HILUX_AIR_OUTLET_SERVO_PULSE_DConfirmed

  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x80 = 128 → 128

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2026. Not supported for 2025.

Ambient air temperature HILUX_AATConfirmed

  • Service 21PID 22
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255−23.3
Range
-23.3 to 65.95 °C
Unit
°C

0x7F = 127 → 127×89.25255−23.3 = 21.15 °C

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2026. Not supported for 2025.

Ambient temperature HILUX_AMBIENT_T_700Confirmed

  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3A = 58 → 58−40 = 18 °C

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Ambient temperature for A/C HILUX_AC_AMB_T

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Blower motor speed level HILUX_BLOWER_MOTOR_SPEED_LEVELConfirmed

  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x03 = 3 → 3

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Cabin temperature HILUX_CABIN_TConfirmed

  • Service 21PID 21
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×63.75255−6.5
Range
-6.5 to 57.25 °C
Unit
°C

0x7B = 123 → 123×63.75255−6.5 = 24.25 °C

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Communication with air conditioner HILUX_COMM_WITH_AIR_CONDITIONER

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Communication with brake HILUX_COMMUNICATION_WITH_BRAKE

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Communication with HV HILUX_COMMUNICATION_WITH_HV

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Communication with valvematic HILUX_COMM_WITH_VALVEMATIC_COMM

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Evaporator fin thermistor HILUX_EVAP_FIN_THERMISTORConfirmed

  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255−29.7
Range
-29.7 to 59.55 °C
Unit
°C

0x5E = 94 → 94×89.25255−29.7 = 3.2 °C

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Set temperature, driver side HILUX_T_DRIVER

  • Service 21PID 29
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Solar sensor, driver side HILUX_SOLAR_DRIVERConfirmed

  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Control

A/C compressor HILUX_A_C_COMPRESSOR

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 64 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

ABS warning HILUX_ABS_WARNING

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018, 2022. Supported for 2021, 2024 to 2025.

Accelerator pedal HILUX_ACCEL_PEDAL

  • Service 22DID 1059
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1.42−28.873
Range
0 to 100 %
Unit
%

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2018, 2021 to 2022, 2024.

Brake warning HILUX_BRAKE_WARNING

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Buzzer HILUX_BUZZER

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Check engine HILUX_CHECK_ENGINEConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Cruise control live brake cancel HILUX_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCH

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

ECB warning HILUX_ECB_WARNING

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Electrical load signal 1 HILUX_ELECTRICAL_LOAD_SIGNAL_1

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Electrical load signal 2 HILUX_ELECTRICAL_LOAD_SIGNAL_2

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Ignition trigger count HILUX_IGNITION_TRIG_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Key remind sound HILUX_KEY_REMIND_SOUNDConfirmed

  • Service 21PID A1
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x08 = 8 → 8

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Neutral position HILUX_NEUTRAL_POSITION_SW_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Parking brake HILUX_PARKING_BRAKE

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2026. Not supported for 2022, 2024 to 2025.

Parking brake HILUX_PARKING_BRAKE_2Confirmed

  • Service 21PID 62
  • Module7D0 → 7D8
  • Every1 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2021 to 2022, 2024. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2018.

Pattern switch HILUX_PATTERN_SWITCH_PWR_M_

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Power steering HILUX_POWER_STEERING_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Shift SW status, d range HILUX_SHIFT_SW_STATUS_D_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Shift SW status, n range HILUX_SHIFT_SW_STATUS_N_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Shift SW status, p range HILUX_SHIFT_SW_STATUS_P_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Shift SW status, r range HILUX_SHIFT_SW_STATUS_R_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Slip indicator HILUX_SLIP_INDICATOR

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Sports mode selection HILUX_SPORTS_MODE_SELECTION_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Sports shift down HILUX_SPORTS_SHIFT_DOWN_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Sports shift up HILUX_SPORTS_SHIFT_UP_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Starter control HILUX_STARTER_CONTROL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Starter signal HILUX_STARTER_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Steering angle HILUX_STEERING_ANGLE

  • Service 22DID 1004
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 1996 to 2020, 2022 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1.5
Range
-410 to 410 °
Unit
°

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2021. Not supported for 2013, 2018, 2022, 2024.

Steering wheel angle HILUX_STEER_ANGLEConfirmed

Positive = counter-clockwise, negative = clockwise.

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 24 to 39 of the reply, 16 bits.

Formula
val10−3276.8
Range
-3276 to 3276 °
Unit
°

0x8044 = 32836 → 3283610−3276.8 = 6.8 °

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Stop light HILUX_STOP_LIGHT

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2026. Not supported for 2022, 2024 to 2025.

Stop light HILUX_STOP_LIGHT_SWITCH

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Tail cancel HILUX_TAIL_CANCELConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

TC HILUX_TC_TERMINAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 61 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Traction brake control HILUX_TRC_BRAKE_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Traction control HILUX_TRC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Traction engine control HILUX_TRC_ENGINE_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Zero point of deceleration HILUX_ZP_DEC

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Zero point of deceleration 2 HILUX_ZP_DEC2

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Zero point of yaw rate HILUX_ZP_YAW_RATE

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Cruise control

Cruise control speed HILUX_CC_SConfirmed

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2012, 2014 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2013, 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

DTCs

2nd air monitor_avail HILUX_2ND_AIR_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

2nd air monitor_incmpl HILUX_2ND_AIR_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

A/C monitor_avail HILUX_A_C_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

A/C monitor_incmpl HILUX_A_C_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Catalyst monitor_avail HILUX_CATALYST_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Catalyst monitor_incmpl HILUX_CATALYST_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Complete parts monitor_avail HILUX_COMPLETE_PARTS_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2013, 2018, 2022. Supported for 2021, 2024 to 2025.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

EGR/VVT monitor_avail HILUX_EGR_VVT_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

EGR/VVT monitor_incmpl HILUX_EGR_VVT_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed

Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.

  • Service 01PID 4E
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

EVAP monitor_avail HILUX_EVAP_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

EVAP monitor_icmpl HILUX_EVAP_MONITOR_ICMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel system monitor_avail HILUX_FUEL_SYSTEM_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Heated catalyst monitor_avail HILUX_HEATED_CATALYST_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Heated catalyst monitor_incmpl HILUX_HEATED_CATALYST_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

MIL HILUX_MIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

MIL ON run distance HILUX_MILON_RUN_DISTANCE

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Misfire monitor_avail HILUX_MISFIRE_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Number of emission DTC HILUX_NUMBER_OF_EMISSION_DTC

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

O2S(A/FS) heater monitor_avail HILUX_O2S_A_FS_HEATER_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

O2S(A/FS) heater monitor_incmpl HILUX_O2S_A_FS_HEATER_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

O2S(A/FS) monitor_avail HILUX_O2S_A_FS_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

O2S(A/FS) monitor_incmpl HILUX_O2S_A_FS_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Running time from MIL ON HILUX_RUNNING_TIME_FROM_MIL_ON

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 4D
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

ECU

Exhaust VVT change angle bank 1 HILUX_EXHAUST_VVT_CHANGE_ANGLE_1

  • Service 22DID 1088
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust VVT hold learn value bank 1 HILUX_EXHAUST_VVT_HOLD_LEARN_VALUE_1

  • Service 22DID 1089
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×399.965535
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust VVT timing most over-advanced learn value bank 1 HILUX_EXHAUST_VVT_TIMING_MOST_OVER_ADVANCED_LEARN_VALUE_1

  • Service 22DID 108F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.9965535
Range
0 to 639.99 °
Unit
°

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Intake VVT most over-retarded learn value bank 1 HILUX_INTAKE_VVT_MOST_OVER_RETARDED_LEARN_VALUE_1

  • Service 22DID 108D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.9965535
Range
0 to 639.99 °
Unit
°

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

VVT-ie duty ratio bank 1 HILUX_VVT_IE_DUTY_RATIO_1

  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 14 of the reply, 15 bits.

Formula
val×399.965535−200
Range
-200 to -0.0531 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

VVT-ie motor direction: forward bank 1 HILUX_VVT_IE_MOTOR_DIRECTION_FORWARD_1

  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Electrical

B+ battery voltage HILUX_BATTERY_VOLTAGE_7C0

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1021
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 20 V
Unit
V

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2018, 2021 to 2022, 2024.

Electric load feedback HILUX_ELEC_LOAD_FB

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 200 to 215 of the reply, 16 bits.

Formula
val×108192−40
Range
-40 to 39.99
Unit
Number

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Engine

A/F heater duty bank 1 sensor 1 HILUX_F_HEATER_DUTY_B1S1

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

A/F ratio learn value high, bank 1 HILUX_AFRL_HIGH_1

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×99.6255−50
Range
0 to 49 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

A/F ratio learn value idle, bank 1 HILUX_AFRL_IDLE_1

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×99.6255−50
Range
0 to 49 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

A/F ratio learn value low, bank 1 HILUX_AFRL_LOW_1

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×99.6255−50
Range
0 to 49 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

A/F ratio learn value mid.1, bank 1 HILUX_AFRL_MID_1_1

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×99.6255−50
Range
0 to 49 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

A/F ratio learn value mid.2, bank 1 HILUX_AFRL_MID_2_1

  • Service 22DID 10A2
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×99.6255−50
Range
0 to 49 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

A/F ratio learned high, bank 1 HILUX_A_F_RATIO_LEARNED_HIGH_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

A/F ratio learned idle, bank 1 HILUX_A_F_RATIO_LEARNED_IDLE_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

A/F ratio learned low, bank 1 HILUX_A_F_RATIO_LEARNED_LOW_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

A/F ratio learned mid 1, bank 1 HILUX_A_F_RATIO_LEARNED_MID_1_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

A/F ratio learned mid 2, bank 1 HILUX_A_F_RATIO_LEARNED_MID_2_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

A/F test results 1, incomplete HILUX_F_TEST_RESULTS_1

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Accelerator sensor volt %, 1 HILUX_ACCEL_SENS_NO_1_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Accelerator sensor volt %, 2 HILUX_ACCEL_SENS_NO_2_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Accessory relay on HILUX_ACC_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Accumulator open HILUX_ACCUMULATOR_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Acoustic control induction system vacuum switching valve on HILUX_ACIS_VSV_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Actual EGR A duty cycle/position EGR_A_ACTSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Actual EGR B duty cycle/position EGR_B_ACTSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Actual engine torque HILUX_ACT_ENG_TQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Actuator power supply on HILUX_ACTUATOR_POWER_SUP_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 146 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

AF lambda B1S1 HILUX_AF_LAMBDA_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

AFS current B1S1 HILUX_AFS_CURRENT_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 127.99 mA
Unit
mA

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Air conditioning compressor HILUX_AC_COMP

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Air mix servo target pulse, driver HILUX_AIR_MIX_SERVO_TARG_DConfirmed

  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x7F = 127 → 127

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Air mix servo, actual pulse, d HILUX_AIR_MIX_SERVO_ACT_DConfirmed

  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x7F = 127 → 127

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Alt voltage - active test HILUX_ALT_VOL_ACTIVE_TEST

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Alt voltage - non active test HILUX_ALT_VOL_NON_ACTIVE

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Alternator output duty HILUX_ALTERNATOR_OUTPUT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Alternator output duty cycle HILUX_ALT_DUTY_CYCLEConfirmed

  • Service 22DID 15FA
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 15 of the reply, 16 bits.

Formula
val164
Range
0 to 399 %
Unit
%

0x0A80 = 2688 → 2688164 = 16.390244 %

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Ambient temperature HILUX_AMBIENT_T

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Atmosphere pressure HILUX_ATMOSPHERE_PRESSURE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.

Boost pressure sensor A BP_A_ACTSAE J1979Confirmed

Actual turbocharger/supercharger A boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Boost pressure sensor B BP_B_ACTSAE J1979Confirmed

Actual turbocharger/supercharger B boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018, 2022. Supported for 2013, 2021, 2024 to 2025.

Calculated load_7e0 HILUX_CALCULATED_LOAD_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Catalyst temperature B1S1 HILUX_CATALYST_T_B1S1

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Catalyst temperature B1S2 HILUX_CATALYST_T_B1S2

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Catalyst temperature bank 2 sensor 1 HILUX_CAT_T_BANK_2_SENS_1

  • Service 22DID 1F3D
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Catalyst temperature bank 2 sensor 2 HILUX_CAT_T_BANK_2_SENS_2

  • Service 22DID 1F3F
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Catalyst temperature, bank 1 sensor 2, variant 2 HILUX_CAT_T_B1S2_V2

  • Service 21PID 3E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Check mode on HILUX_CHECK_MODE_ON

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Closed throttle position switch on HILUX_CLOSED_THROTTLE_POS_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 125 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Codes, include history HILUX_CODES_INCLUDE

  • Service 21PID E1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Commanded boost pressure A BP_A_CMDSAE J1979Confirmed

Turbocharger/supercharger A commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Commanded boost pressure B BP_B_CMDSAE J1979Confirmed

Turbocharger/supercharger B commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Commanded EGR A duty cycle/position EGR_A_CMDSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Commanded EGR B duty cycle/position EGR_B_CMDSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Continuously variable transmission learning complete HILUX_CVT_LEARNED

  • Service 21PID DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Continuously variable transmission oil pressure HILUX_CVT_OIL_P

  • Service 21PID BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200 kPa
Unit
kPa

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Coolant temp HILUX_COOLANT_TEMP

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Coolant temperature HILUX_COOLANT_TConfirmed

  • Service 21PID 23
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.5
Range
0 to 127.5 °C
Unit
°C

0x6E = 110 → 110×0.5 = 55 °C

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Coolant water route switching valve 1, closed? HILUX_COOLANT_VALVE_1_CLOSE

  • Service 22DID 282C
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Coolant water route switching valve 2, closed? HILUX_COOLANT_VALVE_2_CLOSE

  • Service 22DID 2847
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Cooling fan duty ratio HILUX_COOLING_FAN_DUTY_RATIO

  • Service 22DID 1046
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×127.5255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cruise control on HILUX_CRUISE_CTRL_ON

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Cylinder 1 injection volume HILUX_CYL_1_INJ_VOLUMEConfirmed

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Cylinder 2 injection volume HILUX_CYL_2_INJ_VOLUMEConfirmed

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

0x8017 = 32791 → 32791×195311000000−640 = 0.441021

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Cylinder 3 injection volume HILUX_CYL_3_INJ_VOLUMEConfirmed

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

0x8015 = 32789 → 32789×195311000000−640 = 0.401959

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Cylinder 4 injection volume HILUX_CYL_4_INJ_VOLUMEConfirmed

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Bits 48 to 63 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Cylinder number HILUX_CYLINDER_NUMBER

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Destination HILUX_DESTINATION

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Diesel particulate and nitrogen oxide reduction regeneration status HILUX_DPF_REGEN_STATConfirmed

  • Service 22DID 119B
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Diesel particulate filter accumulation level HILUX_DPF_ACCUMULATION

  • Service 21PID 38
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×2
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Diesel particulate filter differential pressure HILUX_DPF_DIFF_PConfirmed

  • Service 22DID 1F7A
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 kPa
Unit
kPa

0x005C = 92 → 92100 = 0.92 kPa

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Dist battery cable disconnect HILUX_DIST_BATT_CABLE

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

EGR A error EGR_A_ERRSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

EGR B error EGR_B_ERRSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Electric fan motor on HILUX_ELEC_FAN_MOTOR_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Electric thermostat duty ratio HILUX_ELECTRIC_THERMOSTAT_DUTY_RATIO

  • Service 22DID 2829
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Electric water pump HILUX_ELECTRIC_WATER_PUMP

  • Service 22DID 2827
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Electric water pump RPM HILUX_EWP_RPM

  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Electric water pump target speed HILUX_EWP_TARGET_VSS

  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Engine coolant temp HILUX_ECTConfirmed

  • Service 21PID 26
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255+1.3
Range
1.3 to 90.55 °C
Unit
°C

0x9A = 154 → 154×89.25255+1.3 = 55.2 °C

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022. Supported for 2013, 2018, 2021, 2024 to 2025.

Engine coolant temperature, ignition on HILUX_ECT_IGNConfirmed

  • Service 22DID 1041
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×62.5100−40
Range
-40 to 119.375 °C
Unit
°C

0x9D = 157 → 157×62.5100−40 = 58.125 °C

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Engine coolant temperature, initial HILUX_ECT_INITConfirmed

  • Service 22DID 1041
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×62.5100−40
Range
-40 to 119.375 °C
Unit
°C

0x99 = 153 → 153×62.5100−40 = 55.625 °C

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Engine independent HILUX_ENG_INDEPENDENT

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 91 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Engine independent control HILUX_ENG_INDEPENDENT_CTRL

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil pressure HILUX_EOPConfirmed

  • Service 22DID 1074
  • Module700 → 708
  • Every250 ms
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10128
Range
0 to 5119.92 kPa
Unit
kPa

0x008E = 142 → 142×10128 = 11.09375 kPa

Confirmed for 2021 to 2022, 2024. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2018.

Engine oil pressure control valve HILUX_EOP_CONTROL_VALVE

  • Service 22DID 2848
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0762939
Range
0 to 4999.9207 mA
Unit
mA

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Engine oil temperature HILUX_EOT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Engine oil temperature HILUX_EOT_700

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 107B
  • Module700 → 708
  • Every5 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Engine oil temperature, previous trip HILUX_PREV_TRIP_EOT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Engine oil temperature, variation 2 HILUX_EOT_V2

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1F5C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2022. Supported for 2013, 2018, 2021, 2024 to 2025.

Engine run time HILUX_ENGINE_RUN_TIME

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Engine run time, up to 255 sec. only HILUX_ENG_RUN_TIME_UP_255

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Engine stall control FB flow HILUX_ENG_STALL_CTRL_FB

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096−40
Range
-40 to 39.99
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Engine start hesitation HILUX_ENG_START_HESIT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bit 237 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Engine starting time HILUX_ENG_START_TConfirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 ms
Unit
ms

0x0000 = 0 → 0×10 = 0 ms

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

EVAP purge duty HILUX_EVAP_PURGE_DUTY

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Evaporative purge duty HILUX_EVAP_PURGE_DUTY_7E0

  • Service 21PID 2E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Evaporative purge flow HILUX_EVAP_PURGE_FLOW

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.99 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Evaporative purge vacuum switching valve on HILUX_EVAP_PURGE_VSV_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Evaporator target temp HILUX_EVAP_TARG_TConfirmed

  • Service 21PID 4C
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327.68 to 327.67
Unit
Number

0x81C2 = 33218 → 33218100−327.68 = 4.5

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Exhaust gas recirculation step position HILUX_EGR_STEP_POSITION

  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Exhaust gas recirculation temperature HILUX_EGR_T

  • Service 21PID ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5385
Range
0 to 159 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Exhaust gas recirculation valve step HILUX_EGR_STEP

  • Service 21PID E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Exhaust VVT oil control valve control duty HILUX_EXHAUST_VVT_OCV_CONTROL_DUTY

  • Service 22DID 1062
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×40065535
Range
0 to 400 %
Unit
%

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Exhaust VVT target angle B1 HILUX_EXHAUST_VVT_TARGET_ANGLE_B1

  • Service 22DID 1071
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Fuel cut for engine stop request HILUX_F_C_ENG_STOP_REQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 92 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel cut TAU on HILUX_FC_TAU_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel filter temperature HILUX_FFT

  • Service 22DID 109A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

G sensor calibration, complete HILUX_G_SENS_CALIBRATION

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

G sensor learning value HILUX_G_SENS_LEARNING

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Glass humidity HILUX_GLASS_HUMIDITY

  • Service 21PID B1
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Glass temperature HILUX_GLASS_T

  • Service 21PID AF
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9500−557.8
Range
-557 to 621 °F
Unit
°F

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

HV communication open HILUX_HV_COMMUNICATION_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Idle control HILUX_IDLE_CTRL

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Idle spark advance control 1 HILUX_IDLE_SPARK_ADVN_CTRL_1

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Idle spark advance control 2 HILUX_IDLE_SPARK_ADVN_CTRL_2

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Idle spark advance control 3 HILUX_IDLE_SPARK_ADVN_CTRL_3

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Idle spark advance control 4 HILUX_IDLE_SPARK_ADVN_CTRL_4

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Idle spark advance control, cylinder 1 HILUX_IDLE_SAC_CYL_1

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Idle spark advance control, cylinder 2 HILUX_IDLE_SAC_CYL_2

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Idle spark advance control, cylinder 3 HILUX_IDLE_SAC_CYL_3

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Idle spark advance control, cylinder 4 HILUX_IDLE_SAC_CYL_4

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Idle speed control feedback HILUX_ISC_FB

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 168 to 183 of the reply, 16 bits.

Formula
val×108192−40
Range
-40 to 39.99
Unit
Number

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Idle speed control flow HILUX_ISC_FLOW

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 120 to 135 of the reply, 16 bits.

Formula
val×108192
Range
0 to 79.99
Unit
Number

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Idle speed control learning HILUX_IDLE_SPD_CTRL

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 93 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Idle speed control learning value HILUX_ISC_LEARN

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 184 to 199 of the reply, 16 bits.

Formula
val×108192−40
Range
-40 to 39.99
Unit
Number

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Idle speed control learning value, l/s HILUX_IDLE_SPD_CTRL_L_S

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val×0.0012206912
Range
0 to 79.99
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Idle speed control position HILUX_ISC_POS

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 136 to 151 of the reply, 16 bits.

Formula
val×12516384
Range
0 to 499.99 °
Unit
°

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

IG OFF elapsed time HILUX_IG_OFF_ELAPSED_TIME

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 min
Unit
min

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Ignition advance HILUX_IGN_ADVANCE

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Ignition advance HILUX_SPARKADV_21

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Immobilizer communication on HILUX_IMMOBILIZER_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 120 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Initial engine coolant temperature HILUX_INITIAL_ECT

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×531850−40
Range
-40 to 119.3
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Initial intake air temperature HILUX_INITIAL_IAT

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection HILUX_INJECTION

  • Service 22DID 1019
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1DIRECTDirect
2BOTHBoth

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection duration for cylinder 1 HILUX_INJ_DUR_CYL_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection feedback value 1 HILUX_INJ_FEEDBACK_1Confirmed

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

0x7A = 122 → 122×532−20 = -0.9375

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Injection feedback value 1 HILUX_INJ_FEEDBACK_1_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection feedback value 2 HILUX_INJ_FEEDBACK_2Confirmed

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

0x7F = 127 → 127×532−20 = -0.15625

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Injection feedback value 2 HILUX_INJ_FEEDBACK_2_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection feedback value 3 HILUX_INJ_FEEDBACK_3Confirmed

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

0x83 = 131 → 131×532−20 = 0.46875

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Injection feedback value 3 HILUX_INJ_FEEDBACK_3_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection feedback value 4 HILUX_INJ_FEEDBACK_4Confirmed

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

0x81 = 129 → 129×532−20 = 0.15625

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Injection feedback value 4 HILUX_INJ_FEEDBACK_4_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection feedback value 5 HILUX_INJ_FEEDBACK_5

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection feedback value 6 HILUX_INJ_FEEDBACK_6

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection volume HILUX_INJ_VOL

  • Service 22DID 1017
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3200
Range
0 to 20 L
Unit
L

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Injection volume - target HILUX_INJ_VOLUME_TGTConfirmed

  • Service 22DID 112C
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000
Range
0 to 15
Unit
Raw value

0x0000 = 0 → 0×195311000000 = 0

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Injection volume 1 HILUX_INJ_VOLUME_1

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection volume 2 HILUX_INJ_VOLUME_2

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection volume 3 HILUX_INJ_VOLUME_3

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection volume 5 HILUX_INJ_VOLUME_5

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection volume 6 HILUX_INJ_VOLUME_6

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection volume per 10 injections, cylinder 1 HILUX_INJ_VOL_CYL_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32000000
Range
0 to 0.002 L
Unit
L

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injection volume total HILUX_INJ_VOLUME_TOTConfirmed

  • Service 22DID 112F
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Injector port HILUX_INJECTOR_PORT

  • Service 22DID 1018
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Injector pulse width HILUX_INJ_PW

  • Service 21PID E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1631275
Range
0 to 32.6 ms
Unit
ms

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Injector pulse width HILUX_INJ_WIDTH

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Input shaft speed HILUX_SPD_NIN

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Intake air HILUX_INTAKE_AIR

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Intake air temperature HILUX_IAT_21

  • Service 21PID 0F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Intake air temperature, bank 1 sensor 1 HILUX_IAT_B1S1Confirmed

  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3E = 62 → 62−40 = 22 °C

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Intake air temperature, bank 1 sensor 2 HILUX_IAT_B1S2

  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing for 1996 to 2021, 2023 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Supported for 2022.

Intake air temperature, previous trip HILUX_PREV_TRIP_IATConfirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x14 = 20 → 20−40 = -20 °C

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Intake VVT change angle, bank 1 HILUX_INTAKE_VVT_CHANGE_ANGLE_BANK_1

  • Service 22DID 1087
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Intake VVT target angle B1 HILUX_INTAKE_VVT_TARGET_ANGLE_B1

  • Service 22DID 106F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Integrated engine run time HILUX_INTEGRATED_ENG_RUN

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Intercooler coolant temperature HILUX_INTERCOOLER_ECT

  • Service 22DID 119C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Intercooler water pump HILUX_INTERCOOLER_WATER

  • Service 22DID 2820
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8013107
Range
0 to 300 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Internal temperature HILUX_ECU_INTERNAL_T

  • Service 22DID 105E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Judge time engine ignition HILUX_JUDGE_TIME_ENG_IGN

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Judge time engine output HILUX_JUDGE_TIME_ENG

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Knock adjust HILUX_KNOCK_ADJUST

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Knock adjust HILUX_KNOCK_ADJUST_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Knock correct learn value HILUX_KNOCK_CORRECT_LEARN

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val32−1024
Range
-1024 to 1023 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Knock correction, learned value HILUX_KNOCK_CORRECT_LEARNED_VALUE

  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×312.510000−1024
Range
-1024 to 1023
Unit
Number

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Knock feedback HILUX_KNOCK_FEEDBACK

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Knock feedback HILUX_KNOCK_FEEDBACK_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Knock feedback value HILUX_KNOCK_FEEDBACK_VALUE

  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×312.510000−1024
Range
-1024 to 1023
Unit
Number

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Long FT B1S1 HILUX_LONG_FT_B1S1

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.218 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Long-term fuel trim, bank 1 HILUX_LTFT1_21

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.7809803922−100
Range
-100 to 99.15 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Low revolution control HILUX_LOW_RPM_CTRL

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bit 234 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Low revolution for engine start HILUX_LOW_RPM_START

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bit 236 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Main idle HILUX_MAIN_IDLE

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

MAP HILUX_MAP

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Mass air flow HILUX_MAF

Pelican can show this parameter as the mass air flow.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 655.35 g/s
Unit
g/s

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Mass air flow HILUX_MAF_21

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 g/s
Unit
g/s

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Master cylinder open HILUX_MASTER_CYLINDER_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Master cylinder sensor temperature HILUX_MASTER_CYL_TEMPConfirmed

  • Service 22DID 1006
  • Module7B0 → 7B8
  • Every5 s
  • Testing for 1996 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−80
Range
-20 to 100 °C
Unit
°C

0x77 = 119 → 119−80 = 39 °C

Confirmed for 2021 to 2022, 2024. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2018.

Misfire count, all cylinders HILUX_MISFIRE_CNT

  • Service 22DID 10A5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Misfire count, cylinder 1 HILUX_MISFIRE_CYL1

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Misfire count, cylinder 2 HILUX_MISFIRE_CYL2

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Misfire count, cylinder 3 HILUX_MISFIRE_CYL3

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Misfire count, cylinder 4 HILUX_MISFIRE_CYL4

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Misfire load HILUX_MISFIRE_LOAD_700

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×510255
Range
0 to 510 %
Unit
%

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Misfire margin HILUX_MISFIRE_MARGIN_700

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 rpm
Unit
rpm

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Misfire RPM HILUX_MISFIRE_RPM

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Misfire RPM HILUX_MISFIRE_RPM_700

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×6375255
Range
0 to 6375 rpm
Unit
rpm

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Misfire test result, incomplete HILUX_MIS_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Model year HILUX_MODEL_YEAR

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val+1900
Range
1900 to 2155
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

O2 heater b1s2_active HILUX_O2_HEATER_B1S2

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 68 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

O2 heater current val bank 1 sensor 2 HILUX_O2_HEATER_CURR_VAL

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 A
Unit
A

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

O2S B1S2 HILUX_O2S_B1S2

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×51000
Range
0 to 1.275 V
Unit
V

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Open side malfunction on HILUX_OPEN_SIDE_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 145 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Output shaft speed HILUX_SPD_NOUT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

OXS1, A/FS2 test result, incomplete HILUX_OXS1_FS2_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Oxygen sensor voltage, bank 1 sensor 1 HILUX_O2S11_V

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.0049960784
Range
0 to 1.27 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

PM accumulation ratio - bank 1 HILUX_PM_ACCUMULATION_RAT_1Confirmed

  • Service 22DID 1105
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 %
Unit
%

0x0E = 14 → 14×2 = 28 %

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Purge cut vacuum switching valve duty HILUX_PURGE_CUT_VSV_DUTY

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Racing operation HILUX_RACING_OPERATION

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 90 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Regulator pressure HILUX_REGULATOR_P

  • Service 21PID 53
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×37510525500−456.68
Range
-456.68 to 3294 kPa
Unit
kPa

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Request engine run time HILUX_REQ_ENG_RUN_TIME

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Request warm-up HILUX_REQ_WARM_UP

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 89 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Requested engine torque HILUX_REQ_ENG_TQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Rough idle cyl.1 HILUX_ROUGH_IDLE_1Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2026. Not supported for 2025.

Rough idle cyl.2 HILUX_ROUGH_IDLE_2Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2026. Not supported for 2025.

Rough idle cyl.3 HILUX_ROUGH_IDLE_3Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2026. Not supported for 2025.

Rough idle cyl.4 HILUX_ROUGH_IDLE_4Confirmed

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2026. Not supported for 2025.

Short FT B1S1 HILUX_SHORT_FT_B1S1

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.218 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Starter count HILUX_STARTER_CNTConfirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 33 to 39 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

0b0000001 = 1 → 1

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Starter relay on HILUX_STARTER_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Stroke open HILUX_STROKE_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

System guard on HILUX_SYSTEM_GUARD_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 144 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle fully close learn HILUX_THROTTLE_FULLY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle idle position on HILUX_THROTTLE_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 149 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle motor current HILUX_THROTTLE_MOTOR

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×564
Range
0 to 19.9 A
Unit
A

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle motor DUTY HILUX_THROTTLE_MOTOR_DUTY

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Throttle motor duty, close HILUX_THROTTLE_MOTOR_DUTY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle motor duty, open HILUX_THROTTLE_MOTOR_DUTY_OPEN

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle position HILUX_THROTTLE_21

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle position HILUX_TPS

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 104 to 119 of the reply, 16 bits.

Formula
val×12516384
Range
0 to 499.99 °
Unit
°

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Throttle position command HILUX_THROTTLE_POS_COMMAND

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle position, number 1 HILUX_THROTTLE_POS_NUMBER_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle position, number 2 HILUX_THROTTLE_POS_NUMBER_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle require position HILUX_THROTTLE_REQUIRE_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle sensor open position 1 HILUX_THROTTLE_SENS_OPEN_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle sensor open position 2 HILUX_THROTTLE_SENS_OPEN_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Throttle sensor position HILUX_THROTTLE_SENSOR_POSITION

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Throttle sensor volt %, 1 HILUX_THROTTLE_SENSOR_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Throttle sensor volt %, 2 HILUX_THROTTL_SENSOR_2_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Time after DTC cleared HILUX_TIME_AFTER_DTC_CLEARED

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Total fuel trim, bank 1 HILUX_TOT_FT_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100256−50
Range
-50 to 49.6 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature HILUX_ATF_T

  • Service 01PID B4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2026.

Transmission fluid temperature HILUX_ATF_TEMP_700

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1638
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2018, 2021 to 2022, 2024.

Transmission output shaft speed HILUX_TRANS_OUT_RPM

  • Service 21PID BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Turbine speed HILUX_SPD_NT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Valvematic current angle HILUX_VALVEMATIC_CURRENT

  • Service 21PID 31
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Valvematic, target angle HILUX_VALVEMATIC_TGT_ANG

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Variable valve timing advance fail HILUX_VVT_ADV_FAIL

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bit 235 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Variable valve timing aim angle 1 HILUX_VARIABLE_VLV_TIM_AIM_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333218450
Range
0 to 399 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Variable valve timing change angle 1 HILUX_VARIABLE_VLV_TIM_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.0097642481
Range
0 to 639 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Variable valve timing control status 1 on HILUX_VARIABLE_VLV_TIM_1_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Variable valve timing oil control valve duty 1 HILUX_VARIABLE_VLV_TIM_OIL_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0061020829
Range
0 to 399 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Variable valve timing oil temperature HILUX_VVTOTConfirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x12 = 18 → 18−40 = -22 °C

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Variable valve timing opening angle bank 1 HILUX_VVT_IE_OPENING_ANGLE_BANK_1

  • Service 22DID 2843
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Vehicle load HILUX_VEHICLE_LOAD

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Vehicle speed HILUX_VSS_21

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Vehicle speed sensor test result, incomplete HILUX_SPD_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Warmup cycle cleared DTC HILUX_WARMUP_CYCLE_CLEARED_DTC

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Catalyst

Catalyst temperature, bank 1 sensor 1 HILUX_CAT_T_11

  • Service 22DID 1F3C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Catalyst temperature, bank 1 sensor 2 HILUX_CAT_T_12

  • Service 22DID 1F3E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Internal

Actual EGR A supported EGR_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Actual EGR A supported EGR_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Commanded EGR A supported EGR_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Commanded EGR A supported EGR_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

EGR A error supported EGR_A_ERR_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

EGR A error supported EGR_B_ERR_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.

Misfires

All cylinders misfire count HILUX_ALL_CYLINDERS_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder #1 misfire count HILUX_CYL1_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder #2 misfire count HILUX_CYL2_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder #3 misfire count HILUX_CYL3_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder #4 misfire count HILUX_CYL4_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Misfire load HILUX_MISFIRE_LOAD

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×4256
Range
0 to 3.98
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Misfire margin HILUX_MISFIRE_MARGIN

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 %
Unit
%

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fluids

Distance since oil change HILUX_OIL_CHANGE_ODO

  • Service 21PID 41
  • Module7C0 → 7C8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×251460015625
Range
0 to 41038.272 km
Unit
km

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel

Engine fuel rate HILUX_ENG_FUEL_RATE

  • Service 22DID F19D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel cut HILUX_FUEL_CUT

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel cut HILUX_FUEL_CUT_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 121 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel cut time HILUX_FUEL_CUT_TIME

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×537512
Range
0 to 68734.9511
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel injection timing HILUX_FUEL_INJ_TIM

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel level HILUX_FLI

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 1F2F
  • Module700 → 708
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2018, 2021 to 2022, 2024.

Fuel level HILUX_FUEL_LEVEL

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 1022
  • Module7C0 → 7C8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 1996 to 2012, 2014 to 2020, 2023 to 2026. Not supported for 2013, 2021 to 2022.

Fuel level, volume HILUX_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 21PID 29
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5003785
Range
0 to 21 gal
Unit
gal

0x43 = 67 → 67×5003785 = 8.850727 gal

Confirmed for 2018, 2021 to 2022, 2024. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013.

Fuel pressure 1 HILUX_FUEL_P_1Confirmed

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

0x1052 = 4178 → 4178×10 = 41,780 kPa

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Fuel pressure 1 HILUX_FUEL_P_1_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel pressure 2 HILUX_FUEL_P_2Confirmed

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

0x105C = 4188 → 4188×10 = 41,880 kPa

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Fuel pressure 2 HILUX_FUEL_P_2_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel pressure 3 HILUX_FUEL_P_3Confirmed

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

0x102E = 4142 → 4142×10 = 41,420 kPa

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Fuel pressure 3 HILUX_FUEL_P_3_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel pressure 4 HILUX_FUEL_P_4Confirmed

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

0x1058 = 4184 → 4184×10 = 41,840 kPa

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Fuel pressure 4 HILUX_FUEL_P_4_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel pressure 5 HILUX_FUEL_P_5

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel pressure 6 HILUX_FUEL_P_6

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel pump duty ratio HILUX_FP_DUTY_RATIO

  • Service 22DID 106A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0609756098
Range
0 to 3996.0365 kPa
Unit
kPa

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel pump/speed status on HILUX_FUEL_PMP_SPD_STAT_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel return temperature HILUX_FUEL_RETURN_TConfirmed

  • Service 22DID 1141
  • Module700 → 708
  • Every5 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x42 = 66 → 66−40 = 26 °C

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Fuel temperature 1 HILUX_FUEL_T_1Confirmed

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x42 = 66 → 66−40 = 26 °C

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Fuel temperature 1 HILUX_FUEL_T_1_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel temperature 2 HILUX_FUEL_T_2Confirmed

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x43 = 67 → 67−40 = 27 °C

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Fuel temperature 2 HILUX_FUEL_T_2_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel temperature 3 HILUX_FUEL_T_3Confirmed

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x44 = 68 → 68−40 = 28 °C

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Fuel temperature 3 HILUX_FUEL_T_3_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel temperature 4 HILUX_FUEL_T_4Confirmed

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x42 = 66 → 66−40 = 26 °C

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Fuel temperature 4 HILUX_FUEL_T_4_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel temperature 5 HILUX_FUEL_T_5

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Fuel temperature 6 HILUX_FUEL_T_6

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

High fuel pressure, actual HILUX_HFP_ACTUALConfirmed

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x104D = 4173 → 4173×10 = 41,730 kPa

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

High fuel pressure, target HILUX_HFP_TARGETConfirmed

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0F16 = 3862 → 3862×10 = 38,620 kPa

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Immobilizer fuel cut HILUX_IMMOB_FUEL_CUTConfirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Low fuel pressure HILUX_LFP

  • Service 22DID 10CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.8
Range
0 to 3276.7 kPa
Unit
kPa

In testing for 1996 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.

Low fuel pressure HILUX_LOW_FUEL_PRESSUREConfirmed

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x105D = 4189 → 4189×10 = 41,890 kPa

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Reservoir warning HILUX_RESERVOIR_WARNING

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Target air-fuel ratio HILUX_TARGET_AIR_FUEL_RATIO

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Vehicle fuel rate HILUX_VEH_FUEL_RATE

  • Service 22DID F19D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Lights

Hazard switch history HILUX_HAZARD_SWITCH_HISTORY

  • Service 21PID BC
  • Module7B0 → 7B8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0INCOMPLETEIncomplete
1COMPLETEComplete

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Rheostat HILUX_RHEOSTAT

Higher values are brighter

  • Service 21PID 68
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Stop light relay HILUX_STOP_LIGHT_RELAY

  • Service 21PID 3C
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Movement

Accelerator fully close learn 1 HILUX_ACCEL_FULLY_CLOSE_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Accelerator fully close learn 2 HILUX_ACCEL_FULLY_CLOSE_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Accelerator idle position on HILUX_ACCEL_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 148 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Accelerator position HILUX_ACCEL_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Accelerator sensor out, number 1 HILUX_ACCEL_SENS_OUT_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Accelerator sensor out, number 2 HILUX_ACCEL_SENS_OUT_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Average engine speed of all cylinders HILUX_AV_RPM_ALL_CYL

Pelican can show this parameter as the engine speed.

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Compressor speed HILUX_COMP_SPD

  • Service 21PID 49
  • Module7C4 → 7CC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Compressor, target speed HILUX_COMP_TGT_SPD

  • Service 21PID 4A
  • Module7C4 → 7CC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Cruise control speed HILUX_CRUISE_CTRL_SPD

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Engine speed HILUX_ENGINE_SPEED

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 16383 rpm
Unit
rpm

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Engine speed of cylinder 1 HILUX_RPM_CYL_1

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Engine speed of cylinder 2 HILUX_RPM_CYL_2

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Engine speed of cylinder 3 HILUX_RPM_CYL_3

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Engine speed of cylinder 4 HILUX_RPM_CYL_4

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Engine speed, starter off HILUX_ENG_SPD_START_OFFConfirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×100128
Range
0 to 51199 rpm
Unit
rpm

0x04A1 = 1185 → 1185×100128 = 925.78125 rpm

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

FL wheel acceleration HILUX_FL_ACC

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 m/s²
Unit
m/s²

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

FR wheel acceleration HILUX_FR_ACC

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 m/s²
Unit
m/s²

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Front left wheel speed HILUX_FL_VSSConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Front left wheel speed? HILUX_FL_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Front right wheel speed HILUX_FR_VSSConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Front right wheel speed? HILUX_FR_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

High voltage, target engine speed HILUX_HIGH_V_TGT_RPM

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Intercooler water pump speed, raw count HILUX_IWP_SPEED

  • Service 22DID 1075
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Minimum engine speed HILUX_MIN_RPM

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Rear left wheel speed HILUX_RL_VSSConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Rear left wheel speed? HILUX_RL_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Rear right wheel speed HILUX_RR_VSSConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Rear right wheel speed? HILUX_RR_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

RL wheel acceleration HILUX_RL_ACC

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 m/s²
Unit
m/s²

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

RR wheel acceleration HILUX_RR_ACC

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 m/s²
Unit
m/s²

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Vehicle speed HILUX_VEHICLE_SPEED

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Vehicle speed HILUX_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7B0 → 7B8
  • Every200 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.28
Range
0 to 326 km/h
Unit
km/h

0x00 = 0 → 0×1.28 = 0 km/h

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2013. Supported for 2018, 2021 to 2022, 2024 to 2025.

Vehicle speed, 7C0 HILUX_VSS_7C0Confirmed

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Orientation

Deceleration open HILUX_DECELERATION_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Deceleration sensor HILUX_DECEL

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

In testing for 1996 to 2021, 2023, 2026. Not supported for 2022, 2024 to 2025.

Deceleration sensor, alternate HILUX_DECEL2

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

In testing for 1996 to 2021, 2023, 2026. Not supported for 2022, 2024 to 2025.

Lateral g HILUX_LAT_GConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.5 to 2.5 g
Unit
g

0x01 = 1 → 150 = 0.02 g

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Longitudinal g HILUX_LNG_GConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.5 to 2.5 g
Unit
g

0x01 = 1 → 150 = 0.02 g

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Yaw rate open error? HILUX_YAW_RATE_ERROR

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Yaw rate sensor HILUX_YAW_RATE

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Yaw rate sensor, alternate HILUX_YAW_RATE2

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Yaw rate value, degrees/sec HILUX_YAW_RATE3Confirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

0x81 = 129 → 129−128 = 1 °

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Zero point of yaw rate HILUX_ZERO_POINT_OF_YAW_RATE

  • Service 21PID A1
  • Module7B0 → 7B8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Seatbelts

Buckle switch, left side HILUX_BUCKLE_LS

  • Service 21PID 04
  • Module780 → 788
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Supported for 2022.

Buckle switch, right side HILUX_BUCKLE_RS

  • Service 21PID 04
  • Module780 → 788
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Supported for 2022.

P-seatbelt buckle HILUX_P_SEATBELT_BUCKLEConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Reverse beep HILUX_REVERSE_BEEP

  • Service 21PID AC
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
On or off

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Seat belt beeps HILUX_SEAT_BELT_BEEPConfirmed

  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 1996 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xE0 = 224 → 224

Confirmed for 2022, 2024. In testing for 1996 to 2021, 2023, 2025 to 2026.

Stats

Inspection mode HILUX_INSPECTION_MODE

  • Service 21PID A6
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Tires

Brake assist status HILUX_BA_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Front left wheel ABS status HILUX_FL_WHEEL_ABS_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Front left wheel VSC control HILUX_FL_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Front right wheel ABS status HILUX_FR_WHEEL_ABS_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Front right wheel cylinder open HILUX_FR_WHEEL_CYLINDER_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Front right wheel VSC control HILUX_FR_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Predictive brake assist status HILUX_PBA_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Rear left wheel ABS status HILUX_RL_WHEEL_ABS_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Rear left wheel EBS status HILUX_RL_WHEEL_EBD_CTRL_STATUS

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Rear left wheel VSC control HILUX_RL_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Rear right wheel ABS status HILUX_RR_WHEEL_ABS_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Rear right wheel EBS status HILUX_RR_WHEEL_EBD_CTRL_STATUS

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Rear right wheel VSC control HILUX_RR_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Torque converter turbine wheel speed HILUX_TQ_CONV_TURBINE_WHL

  • Service 21PID DA
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12750
Range
0 to 6 rpm
Unit
rpm

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Wheel cylinder pressure HILUX_WHEEL_CYLINDER_PRESSURE

  • Service 21PID 07
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission

Current gear HILUX_GEAR_V2

  • Service 21PID DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Gear HILUX_GEARConfirmed

  • Service 21PID 85
  • Module7E0 → 7E8
  • Every500 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 20
Unit
Number

0x01 = 1 → 1

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Gear HILUX_GEAR_700Confirmed

  • Service 22DID 1621
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Gear lock-up HILUX_GEAR_LOCKUPConfirmed

Mechanism within the automatic transmission that momentarily locks the gears during gear changes, providing a smoother and more efficient transition between different gears, especially when accelerating or decelerating; essentially helps minimize power loss and jerkiness during gear shifts.

  • Service 21PID 85
  • Module7E0 → 7E8
  • Every500 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Lock up state HILUX_AT_LOCK_UP_STATEConfirmed

  • Service 22DID 1620
  • Module700 → 708
  • Every1 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Neutral control HILUX_NEUTRAL_CTRL

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bit 233 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Neutral range status HILUX_N_RANGE_STS

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bit 232 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Torque converter and TE1 on HILUX_TQ_CONV_TE1_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid post-converter temperature, variant 3 HILUX_TRANS_FLUID_POST_T_3Confirmed

  • Service 22DID 1628
  • Module700 → 708
  • Every5 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

0x4920 = 18720 → 18720256−40 = 33.125 °C

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Transmission fluid temperature, pan var.3 HILUX_ATF_T_PAN_V3Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1627
  • Module700 → 708
  • Every5 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

0x46A0 = 18080 → 18080256−40 = 30.625 °C

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Transmission fluid temperature, variant 5 HILUX_ATF_T_V_5

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 8 HILUX_ATF_T_V_8

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 9 HILUX_ATF_T_V_9

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 10 HILUX_ATF_T_V_10_7E1

  • Service 21PID 82
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 11 HILUX_ATF_T_V_11

  • Service 21PID 82
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 12 HILUX_ATF_T_V_12

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 14 HILUX_ATF_T_V_14

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 14 HILUX_ATF_T_V_14_7E1

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 21 HILUX_ATF_T_V_21

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 21 HILUX_ATF_T_V_21_7E1

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission oil pressure calibration, complete HILUX_TRANS_OIL_PRESS

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission shift state ratio HILUX_TRANS_SHIFT_ST_RAT

  • Service 22DID 1622
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×533321845000
Range
0 to 15.999
Unit
Number

In testing for 1996 to 2021, 2023 to 2026. Not supported for 2022.

Transmission temperature, pan HILUX_ATF_PAN_TConfirmed

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

0x5AA0 = 23200 → 23200256−40 = 50.625 °C

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Transmission temperature, torque converter HILUX_ATF_TQC_TConfirmed

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

0x5DC0 = 24000 → 24000256−40 = 53.75 °C

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Trips

Ambient temperature, previous trip HILUX_PREV_TRIP_AMB_T

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 96 to 103 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.

Odometer HILUX_ENG_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 0103
  • Module700 → 708
  • Every30 s
  • Testing for 1996 to 2021, 2023 to 2026

Example reply from a 2022 Toyota Hilux.

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x011330 = 70448 → 70,448 km

Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2026.

Odometer HILUX_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 21PID 28
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x021184 = 135556 → 135,556 km

Confirmed for 2018. In testing for 2010 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2021 to 2022. Supported for 2024 to 2025.

Previous trip distance HILUX_PREV_TRIP_DSTConfirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Toyota Hilux.

Bits 40 to 55 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km
Unit
km

0x0003 = 3 → 3100 = 0.03 km

Confirmed for 2018. In testing for 1996 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.