Parameters
The Toyota C-HR+ has 680 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
+BM voltage CHR_BM_V
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2016 to 2026.
1st turbocharger outlet pressure, control valve CHR_1ST_TRUBOCHARGER_P
- Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2016 to 2026.
2nd turbocharger outlet pressure CHR_2ND_TRUBOCHARGER_OUTLET_P
- Service 22
DID 11AF - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2016 to 2026.
2nd turbocharger outlet pressure, control valve CHR_2ND_TRUBOCHARGER_P
- Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2016 to 2026.
12V battery current CHR_12V_CConfirmed
- Service 22
DID 15F7 - Module
7D2 → 7DA - Every
500 ms - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -125 to 124 A
- Unit
- A
0x7A61 = 31329 → = -5.489264 A
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
12V battery temperature CHR_12V_TConfirmed
- Service 22
DID 15F8 - Module
7D2 → 7DA - Every
1 s - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x0285 = 645 → = 24.5 °C
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
12V battery voltage CHR_12V_V_V2Confirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 15EE - Module
7D2 → 7DA - Every
1 s - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 80.2 V
- Unit
- V
0x28 = 40 → = 12.5917 V
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
12V battery voltage before system main relay CHR_12V_BAT_V_BEFORE_SMR
- Service 22
DID 107E - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 11.56 V
- Unit
- V
In testing for 2019 to 2026.
12V battery voltage smoothed CHR_12V_BAT_V_SMOOTHED
- Service 22
DID 1F42 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2019 to 2026.
Aux battery voltage CHR_AUX_BAT_V
- Service 22
DID 1002 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.95 V
- Unit
- V
In testing for 2019 to 2026.
Aux. battery capacity after IG OFF CHR_AUX_BAT_CAP_AFTER_IG_OFF
- Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 2016 to 2026.
Aux. battery capacity after IG ON CHR_AUX_BAT_CAP_AFTER_IG_ON
- Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 2016 to 2026.
Auxiliary battery current CHR_AUXILIARY_BAT
- Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -12500 to -12451 A
- Unit
- A
In testing for 2019 to 2026.
Battery current CHR_BAT_CURRENT
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2016 to 2026.
Battery current CHR_BAT_CURRENT_700
- Service 22
DID 15F7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2016 to 2026.
Battery heater temperature CHR_BAT_HEATER_T
- Service 22
DID 1824 - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery status of full charge CHR_BAT_STAT_FULL_CHG
- Service 22
DID 15E5 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 32512.5 Ah
- Unit
- Ah
In testing for 2016 to 2026.
Battery temperature CHR_BAT_T
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6513.5 °C
- Unit
- °C
In testing for 2016 to 2026.
Battery temperature CHR_BAT_T_700
- Service 22
DID 15F8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2016 to 2026.
Battery temperature CHR_BAT_T_700_2
- Service 22
DID 1FF8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 2016 to 2026.
Battery temperature 01 CHR_BAT_T_01
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 02 CHR_BAT_T_02
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 03 CHR_BAT_T_03
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 04 CHR_BAT_T_04
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 05 CHR_BAT_T_05
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 06 CHR_BAT_T_06
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 07 CHR_BAT_T_07
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 08 CHR_BAT_T_08
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 09 CHR_BAT_T_09
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 10 CHR_BAT_T_10
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 11 CHR_BAT_T_11
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 12 CHR_BAT_T_12
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 13 CHR_BAT_T_13
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 14 CHR_BAT_T_14
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 15 CHR_BAT_T_15
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature 16 CHR_BAT_T_16
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery voltage CHR_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 1002 - Module
700 → 708 - Every
5 s - Testing for 2016 to 2018, 2020 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 79 V
- Unit
- V
0x2544 = 9540 → = 11.645478 V
Confirmed for 2019, 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026.
Battery voltage CHR_BAT_VConfirmed
- Service 21
PID 13 - Module
7C0 → 7C8 - Every
5 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
0x7A = 122 → = 12.2 V
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2026.
Charge contactor current CHR_SCC_SOLENOID_CURRENTConfirmed
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
0x45 = 69 → 69 mA
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2026.
Charging integrated current of aux. battery CHR_CHG_INTEGRATED
- Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2016 to 2026.
Dark current of battery CHR_DARK_CURRENT_BAT
- Service 22
DID 15E7 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2026.
DC-DC converter high side voltage CHR_DC_DC_CONV_HIGH_SIDE_V
- Service 22
DID 111E - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7999 V
- Unit
- V
In testing for 2019 to 2026.
DC-DC converter low side voltage CHR_DC_DC_CONV_LOW_SIDE_V
- Service 22
DID 111D - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 19.92 V
- Unit
- V
In testing for 2019 to 2026.
DC-DC converter, target voltage before charging CHR_DC_DC_CONV_TGT_V
- Service 22
DID 111F - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7999 V
- Unit
- V
In testing for 2019 to 2026.
Discharging integrated current of aux. battery CHR_DISCHARGING
- Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2016 to 2026.
Distance since last battery cable disconnection CHR_DIST_SINCE_BAT_DISCConfirmed
- Service 22
DID 106C - Module
700 → 708 - Every
30 s - Testing for 2016 to 2018, 2020 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x1B69 = 7017 → 7,017 km
Confirmed for 2019, 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026.
HV battery charge voltage CHR_HVBAT_CHRG_V
- Service 22
DID 1609 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 V
- Unit
- V
In testing for 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.
HV battery charge, maximum CHR_HVBAT_SOC_MAXConfirmed
- Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 2020 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x46 = 70 → = 35 %
Confirmed for 2019, 2022 to 2025. In testing for 2020 to 2021, 2026.
HV battery charge, minimum CHR_HVBAT_SOC_MINConfirmed
- Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 2020 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x38 = 56 → = 28 %
Confirmed for 2019, 2022 to 2025. In testing for 2020 to 2021, 2026.
HV battery current CHR_HVBAT_CConfirmed
Pelican can show this parameter as the traction battery current.
- Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 A
- Unit
- A
0x0298 = 664 → = 66.4 A
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
HV battery maximum temperature CHR_HVBAT_MAX_T
- Service 22
DID 1829 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.
HV battery minimum temperature CHR_HVBAT_MIN_T
- Service 22
DID 182A - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.
HV battery voltage CHR_HVBAT_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 V
- Unit
- V
0x30C0 = 12480 → = 195 V
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
Hybrid battery 1 fan CHR_HYBRID_BAT_1_FAN
- Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2019 to 2026.
Hybrid battery temperature 1 CHR_HYBRID_BAT_T_1
- Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2019 to 2026.
Hybrid battery temperature 2 CHR_HYBRID_BAT_T_2
- Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2019 to 2026.
Hybrid battery temperature 3 CHR_HYBRID_BAT_T_3
- Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2019 to 2026.
Initial engine battery voltage lower limit CHR_INITIAL_ENG_BAT_V_LO
- Service 22
DID 15F6 - Module
700 → 708 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2026.
Main connector solenoid current CHR_SMC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2016 to 2018, 2020 to 2026. Supported for 2019.
Main relay a, solenoid current CHR_SLA_SOLENOID_CURRENTConfirmed
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
0x00 = 0 → 0 mA
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2026.
Main relay r solenoid current CHR_SLR_SOLENOID_CURRENTConfirmed
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
0x00 = 0 → 0 mA
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2026.
Output speed sensor voltage CHR_NOUT_SENS_V
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2016 to 2026.
Regenerative braking cooperation CHR_REGEN_COOPERATIONConfirmed
- Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2026.
Regenerative operation CHR_FR_REGEN_OPERATIONConfirmed
- Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
0x0000 = 0 → 0 N·m
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2026.
Regenerative request CHR_FR_REGEN_REQUESTConfirmed
- Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
0x0000 = 0 → 0 N·m
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2026.
Relay control solenoid current CHR_SRC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2016 to 2018, 2020 to 2026. Supported for 2019.
Service contactor solenoid current CHR_SSC_SOLENOID_CURRENTConfirmed
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
0x2C = 44 → 44 mA
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2026.
Sleep time of battery sensor CHR_SLEEP_TIME_BATSENS
- Service 22
DID 15F0 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 h
- Unit
- h
In testing for 2016 to 2026.
State of charge CHR_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID 1F5B - Module
7D2 → 7DA - Every
1 s - Testing for 2020 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x49 = 73 → = 28.627451 %
Confirmed for 2019, 2022 to 2025. In testing for 2020 to 2021, 2026.
Turbine speed sensor voltage CHR_NT_SENS_V
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2016 to 2026.
Vh-voltage after boosting CHR_VH_V_AFTER_BOOSTING
- Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 V
- Unit
- V
In testing for 2019 to 2026.
Vl-voltage before boosting CHR_VL_V_BEFORE_BOOSTING
- Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 V
- Unit
- V
In testing for 2019 to 2026.
Voltage of battery sensor CHR_V_BATSENS
- Service 22
DID 15EE - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.9979 V
- Unit
- V
In testing for 2016 to 2026.
Cells
HV battery cell #01 voltage CHR_HVBAT_C01_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #02 voltage CHR_HVBAT_C02_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #03 voltage CHR_HVBAT_C03_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #04 voltage CHR_HVBAT_C04_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #05 voltage CHR_HVBAT_C05_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB40A = 46090 → = 3.516442 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #06 voltage CHR_HVBAT_C06_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #07 voltage CHR_HVBAT_C07_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #08 voltage CHR_HVBAT_C08_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #09 voltage CHR_HVBAT_C09_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #10 voltage CHR_HVBAT_C10_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #11 voltage CHR_HVBAT_C11_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #12 voltage CHR_HVBAT_C12_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3FA = 46074 → = 3.515221 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #13 voltage CHR_HVBAT_C13_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3FA = 46074 → = 3.515221 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #14 voltage CHR_HVBAT_C14_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #15 voltage CHR_HVBAT_C15_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #16 voltage CHR_HVBAT_C16_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #17 voltage CHR_HVBAT_C17_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #18 voltage CHR_HVBAT_C18_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #19 voltage CHR_HVBAT_C19_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3BA = 46010 → = 3.510338 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #20 voltage CHR_HVBAT_C20_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #21 voltage CHR_HVBAT_C21_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3FA = 46074 → = 3.515221 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #22 voltage CHR_HVBAT_C22_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3FA = 46074 → = 3.515221 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #23 voltage CHR_HVBAT_C23_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #24 voltage CHR_HVBAT_C24_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB40A = 46090 → = 3.516442 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #25 voltage CHR_HVBAT_C25_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #26 voltage CHR_HVBAT_C26_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #27 voltage CHR_HVBAT_C27_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #28 voltage CHR_HVBAT_C28_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3BA = 46010 → = 3.510338 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #29 voltage CHR_HVBAT_C29_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3AA = 45994 → = 3.509117 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #30 voltage CHR_HVBAT_C30_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3BA = 46010 → = 3.510338 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #31 voltage CHR_HVBAT_C31_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #32 voltage CHR_HVBAT_C32_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3BA = 46010 → = 3.510338 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #33 voltage CHR_HVBAT_C33_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #34 voltage CHR_HVBAT_C34_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #35 voltage CHR_HVBAT_C35_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 544 to 559 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #36 voltage CHR_HVBAT_C36_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 560 to 575 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3BA = 46010 → = 3.510338 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #37 voltage CHR_HVBAT_C37_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 576 to 591 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #38 voltage CHR_HVBAT_C38_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 592 to 607 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3FA = 46074 → = 3.515221 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #39 voltage CHR_HVBAT_C39_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 608 to 623 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3FA = 46074 → = 3.515221 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #40 voltage CHR_HVBAT_C40_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 624 to 639 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3FA = 46074 → = 3.515221 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #41 voltage CHR_HVBAT_C41_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 640 to 655 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3FA = 46074 → = 3.515221 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #42 voltage CHR_HVBAT_C42_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 656 to 671 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3FA = 46074 → = 3.515221 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #43 voltage CHR_HVBAT_C43_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 672 to 687 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #44 voltage CHR_HVBAT_C44_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 688 to 703 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #45 voltage CHR_HVBAT_C45_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 704 to 719 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #46 voltage CHR_HVBAT_C46_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 720 to 735 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #47 voltage CHR_HVBAT_C47_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 736 to 751 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #48 voltage CHR_HVBAT_C48_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 752 to 767 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #49 voltage CHR_HVBAT_C49_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 768 to 783 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #50 voltage CHR_HVBAT_C50_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 784 to 799 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #51 voltage CHR_HVBAT_C51_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 800 to 815 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #52 voltage CHR_HVBAT_C52_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 816 to 831 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #53 voltage CHR_HVBAT_C53_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 832 to 847 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #54 voltage CHR_HVBAT_C54_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 848 to 863 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB3CA = 46026 → = 3.511559 V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #55 voltage CHR_HVBAT_C55_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 864 to 879 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #56 voltage CHR_HVBAT_C56_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 880 to 895 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #57 voltage CHR_HVBAT_C57_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 896 to 911 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #58 voltage CHR_HVBAT_C58_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 912 to 927 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #59 voltage CHR_HVBAT_C59_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2024 Toyota C-HR+.
Bits 928 to 943 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB83A = 47162 → = 3.59823 V
Confirmed for 2024. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #60 voltage CHR_HVBAT_C60_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Example reply from a 2024 Toyota C-HR+.
Bits 944 to 959 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xB82A = 47146 → = 3.597009 V
Confirmed for 2024. In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #61 voltage CHR_HVBAT_C61_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 960 to 975 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #62 voltage CHR_HVBAT_C62_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 976 to 991 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #63 voltage CHR_HVBAT_C63_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #64 voltage CHR_HVBAT_C64_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #65 voltage CHR_HVBAT_C65_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #66 voltage CHR_HVBAT_C66_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #67 voltage CHR_HVBAT_C67_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #68 voltage CHR_HVBAT_C68_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #69 voltage CHR_HVBAT_C69_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #70 voltage CHR_HVBAT_C70_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #71 voltage CHR_HVBAT_C71_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #72 voltage CHR_HVBAT_C72_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #73 voltage CHR_HVBAT_C73_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #74 voltage CHR_HVBAT_C74_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #75 voltage CHR_HVBAT_C75_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #76 voltage CHR_HVBAT_C76_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #77 voltage CHR_HVBAT_C77_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #78 voltage CHR_HVBAT_C78_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #79 voltage CHR_HVBAT_C79_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #80 voltage CHR_HVBAT_C80_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #81 voltage CHR_HVBAT_C81_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #82 voltage CHR_HVBAT_C82_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #83 voltage CHR_HVBAT_C83_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #84 voltage CHR_HVBAT_C84_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #85 voltage CHR_HVBAT_C85_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #86 voltage CHR_HVBAT_C86_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #87 voltage CHR_HVBAT_C87_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #88 voltage CHR_HVBAT_C88_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #89 voltage CHR_HVBAT_C89_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #90 voltage CHR_HVBAT_C90_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #91 voltage CHR_HVBAT_C91_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #92 voltage CHR_HVBAT_C92_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #93 voltage CHR_HVBAT_C93_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #94 voltage CHR_HVBAT_C94_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,488 to 1,503 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #95 voltage CHR_HVBAT_C95_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,504 to 1,519 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
HV battery cell #96 voltage CHR_HVBAT_C96_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2016 to 2021, 2026
Bits 1,520 to 1,535 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2021, 2026. Not supported for 2019.
Climate
Adjusted ambient temperature CHR_ADJUSTED_AMBIENT_TConfirmed
- Service 21
PID 3D - Module
7C4 → 7CC - Every
5 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -30.8 to 50.8 °C
- Unit
- °C
0x5A = 90 → = -2 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Air inlet damper actual pulse CHR_AIR_INLET_DAMPER_ACTUAL_PULSEConfirmed
- Service 21
PID 44 - Module
7C4 → 7CC - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x5C = 92 → 92
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Air inlet damper target pulse CHR_AIR_INLET_DAMPER_TARGET_PULSEConfirmed
- Service 21
PID 44 - Module
7C4 → 7CC - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x5C = 92 → 92
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Air outlet servo actual pulse, driver CHR_AIR_OUTLET_SERVO_ACTU_PULSE_DConfirmed
- Service 21
PID 43 - Module
7C4 → 7CC - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x80 = 128 → 128
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Air outlet servo pulse, driver CHR_AIR_OUTLET_SERVO_PULSE_DConfirmed
- Service 21
PID 43 - Module
7C4 → 7CC - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x80 = 128 → 128
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Ambient air temperature CHR_AAT_7C4Confirmed
- Service 21
PID 22 - Module
7C4 → 7CC - Every
5 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -23.3 to 65.95 °C
- Unit
- °C
0x3C = 60 → = -2.3 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Ambient temperature CHR_AMBIENT_TConfirmed
- Service 22
DID 1F46 - Module
700 → 708 - Every
5 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x3F = 63 → = 23 °C
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
Blower motor speed level CHR_BLOWER_MOTOR_SPEED_LEVELConfirmed
- Service 21
PID 3C - Module
7C4 → 7CC - Every
5 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Cabin temperature CHR_CABIN_TConfirmed
- Service 21
PID 21 - Module
7C4 → 7CC - Every
5 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -6.5 to 57.25 °C
- Unit
- °C
0x4D = 77 → = 12.75 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Communication with air conditioner CHR_COMM_WITH_AIR_CONDITIONER
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Communication with HV CHR_COMMUNICATION_WITH_HV
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Communication with valvematic CHR_COMM_WITH_VALVEMATIC_COMM
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Evaporator fin thermistor CHR_EVAP_FIN_THERMISTORConfirmed
- Service 21
PID 4B - Module
7C4 → 7CC - Every
5 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -29.7 to 59.55 °C
- Unit
- °C
0x51 = 81 → = -1.35 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Evaporator target temperature CHR_EVAP_TARGET_TConfirmed
- Service 21
PID 4C - Module
7C4 → 7CC - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Number
0x8064 = 32868 → = 1
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Set temperature, driver side CHR_T_DRIVER
- Service 21
PID 29 - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Solar sensor, driver side CHR_SOLAR_DRIVERConfirmed
- Service 21
PID 24 - Module
7C4 → 7CC - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Control
A/C compressor CHR_A_C_COMPRESSOR
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 64 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Accelerator pedal CHR_ACCEL_PEDAL
- Service 22
DID 1059 - Module
700 → 708 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2019, 2022 to 2025.
Accelerator pedal, position 1 CHR_ACC_PEDAL_POS_1Confirmed
- Service 22
DID 1F49 - Module
7D2 → 7DA - Every
1 s - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x28 = 40 → = 15.686275 %
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
Accelerator pedal, position 2 CHR_ACC_PEDAL_POS_2Confirmed
- Service 22
DID 1F4A - Module
7D2 → 7DA - Every
1 s - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x51 = 81 → = 31.764706 %
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
Anti-lock brake warning light CHR_ABS_WARNConfirmed
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Brake warning light CHR_BRAKE_WARNConfirmed
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Buzzer CHR_BUZZERConfirmed
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Communication with brake CHR_COMMUNICATION_WITH_BRAKE
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Cruise control live brake cancel CHR_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCH
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Electrical load signal 1 CHR_ELECTRICAL_LOAD_SIGNAL_1
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Electrical load signal 2 CHR_ELECTRICAL_LOAD_SIGNAL_2
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Electronically controlled brake warning light CHR_ECB_WARNConfirmed
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Ignition trigger count CHR_IGNITION_TRIG_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Key remind sound CHR_KEY_REMIND_SOUNDConfirmed
- Service 21
PID A1 - Module
7C0 → 7C8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x18 = 24 → 24
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2026.
Main idle CHR_MAIN_IDLE_SWConfirmed
- Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Neutral position CHR_NEUTRAL_POSITION_SW_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 53 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Parking brake CHR_PARKING_BRAKEConfirmed
- Service 21
PID 62 - Module
7D0 → 7D8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2024 to 2026
Example reply from a 2023 Toyota C-HR+.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019, 2023. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022, 2024 to 2025.
Parking brake CHR_PARKING_BRAKE_SWConfirmed
- Service 21
PID 1F - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Pattern switch CHR_PATTERN_SWITCH_PWR_M
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 42 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Power steering CHR_POWER_STEERING_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Reservoir warning CHR_RESERVOIR_WARNING_SWConfirmed
- Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Shift SW status, drive CHR_SHIFT_SW_STATUS_D_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Shift SW status, neutral CHR_SHIFT_SW_STATUS_N_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Shift SW status, parking CHR_SHIFT_SW_STATUS_P_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Shift SW status, reverse CHR_SHIFT_SW_STATUS_R_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Slip indicator light CHR_SLIP_WARNConfirmed
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Sports mode selection CHR_SPORTS_MODE_SELECTION_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 32 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Sports shift down CHR_SPORTS_SHIFT_DOWN_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 34 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Sports shift up CHR_SPORTS_SHIFT_UP_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 33 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Starter control CHR_STARTER_CONTROL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Starter signal CHR_STARTER_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Steering angle CHR_STEERING_ANGLEConfirmed
- Service 22
DID 1004 - Module
7B3 → 7BB - Every
250 ms - Testing for 2016 to 2023, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -410 to 410 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2024 to 2025. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2019, 2022 to 2023.
Steering wheel angle CHR_STEER_ANGLEConfirmed
Positive = counter-clockwise, negative = clockwise.
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota C-HR+.
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
0x7F30 = 32560 → = -20.8 °
Confirmed for 2019, 2022 to 2023. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2024 to 2025.
TC CHR_TC_TERMINAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 61 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Traction control, brake status CHR_TRC_TRAC__BRAKE_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Cruise control
Cruise control speed CHR_CC_S
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2019, 2022 to 2025.
Details
Inspection mode CHR_INSPECTION_MODEConfirmed
- Service 21
PID A6 - Module
7B0 → 7B8 - Every
60 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
DTCs
2nd air monitor available? CHR_2ND_AIR_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
2nd air monitor incomplete? CHR_2ND_AIR_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
A/C monitor available? CHR_A_C_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
A/C monitor incomplete? CHR_A_C_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Catalyst monitor available? CHR_CATALYST_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Catalyst monitor incomplete? CHR_CATALYST_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Complete parts monitor available? CHR_COMPLETE_PARTS_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2019. Supported for 2020 to 2025.
EGR/VVT monitor available? CHR_EGR_VVT_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
EGR/VVT monitor incomplete? CHR_EGR_VVT_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
EVAP monitor available? CHR_EVAP_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
EVAP monitor_icmpl CHR_EVAP_MONITOR_ICMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Fuel system monitor available? CHR_FUEL_SYSTEM_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Heated catalyst monitor available? CHR_HEATED_CATALYST_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Heated catalyst monitor incomplete? CHR_HEATED_CATALYST_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
MIL CHR_MIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
MIL ON run distance CHR_MILON_RUN_DISTANCE
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Misfire monitor available? CHR_MISFIRE_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Number of emission DTC CHR_NUMBER_OF_EMISSION_DTC
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
O2S heater monitor available? CHR_O2S_A_FS_HEATER_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
O2S heater monitor incomplete? CHR_O2S_A_FS_HEATER_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
O2S monitor available? CHR_O2S_A_FS_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
O2S monitor incomplete? CHR_O2S_A_FS_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Running time from MIL ON CHR_RUNNING_TIME_FROM_MIL_ON
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
ECU
VVT-ie duty ratio bank 1 CHR_VVT_IE_DUTY_RATIO_1Confirmed
- Service 22
DID 108A - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 14 of the reply, 15 bits.
- Formula
- Range
- -200 to -0.0531 %
- Unit
- %
0b100000000000000 = 16384 → = -100.023475 %
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
VVT-ie motor direction: forward bank 1 CHR_VVT_IE_MOTOR_DIRECTION_FORWARD_1Confirmed
- Service 22
DID 108A - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
Electrical
B+ battery voltage CHR_BATTERY_VOLTAGE_7C0Confirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 1021 - Module
7C0 → 7C8 - Every
5 s - Testing for 2016 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2019, 2022 to 2023.
Engine
A/F heater duty bank 1 sensor 1 CHR_F_HEATER_DUTY_B1S1
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2016 to 2026.
A/F ratio learn value high, bank 1 CHR_AF_LEARN_HIGH_PORT_B1Confirmed
- Service 22
DID 10A2 - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2023, 2025 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
A/F ratio learn value idle, bank 1 CHR_AF_LEARN_IDLE_PORT_B1Confirmed
- Service 22
DID 10A2 - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2023, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
A/F ratio learn value low, bank 1 CHR_AF_LEARN_LOW_PORT_B1Confirmed
- Service 22
DID 10A2 - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2023, 2025 to 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
A/F ratio learn value mid.1, bank 1 CHR_AF_LEARN_MID1_PORT_B1Confirmed
- Service 22
DID 10A2 - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
0x8B = 139 → = 4.509804 %
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
A/F ratio learn value mid.2, bank 1 CHR_AF_LEARN_MID2_PORT_B1Confirmed
- Service 22
DID 10A2 - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2023, 2025 to 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
A/F ratio learned high, bank 1 CHR_A_F_RATIO_LEARNED_HIGH_BANK_1Confirmed
- Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
0x91 = 145 → = 6.862745 %
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
A/F ratio learned idle, bank 1 CHR_A_F_RATIO_LEARNED_IDLE_BANK_1Confirmed
- Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
A/F ratio learned low, bank 1 CHR_A_F_RATIO_LEARNED_LOW_BANK_1Confirmed
- Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
A/F ratio learned mid 1, bank 1 CHR_A_F_RATIO_LEARNED_MID_1_BANK_1Confirmed
- Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
0x97 = 151 → = 9.215686 %
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
A/F ratio learned mid 2, bank 1 CHR_A_F_RATIO_LEARNED_MID_2_BANK_1Confirmed
- Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
0x8E = 142 → = 5.686275 %
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
A/F test results 1, incomplete CHR_F_TEST_RESULTS_1
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Accessory relay on CHR_ACC_RELAY_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 46 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Accumulator open CHR_ACCUMULATOR_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Acoustic control induction system vacuum switching valve on CHR_ACIS_VSV_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Actual engine torque CHR_ACT_ENG_TQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2016 to 2026.
Actuator power supply on CHR_ACTUATOR_POWER_SUP_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 146 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Air conditioning compressor CHR_AC_COMP
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Air conditioning power consumption CHR_AC_POWER_CONS
- Service 22
DID 106E - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12.75 kW
- Unit
- kW
In testing for 2019 to 2026.
Air mix servo target pulse, driver CHR_AIR_MIX_SERVO_TARG_D
- Service 21
PID 41 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Air mix servo, actual pulse, d CHR_AIR_MIX_SERVO_ACT_D
- Service 21
PID 41 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Air-fuel equivalence ratio, bank 1 sensor 1 CHR_AF_LAMBDA_B1S1
Pelican can show this parameter as the O2 lambda.
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Air-fuel sensor current, bank 1 sensor 1 CHR_AFS_I_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.99 mA
- Unit
- mA
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Air-fuel sensor voltage, bank 1 sensor 1 CHR_AFS_V_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.99 V
- Unit
- V
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Alt voltage - active test CHR_ALT_VOL_ACTIVE_TEST
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2016 to 2026.
Alt voltage - non active test CHR_ALT_VOL_NON_ACTIVE
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2016 to 2026.
Alternator output duty CHR_ALTERNATOR_OUTPUT
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2016 to 2026.
Alternator output duty cycle CHR_ALT_DUTY_CYCLE
- Service 22
DID 15FA - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Ambient temperature CHR_AAT_7D2Confirmed
- Service 22
DID 1F46 - Module
7D2 → 7DA - Every
1 s - Testing for 2020 to 2022, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
Barometric pressure CHR_BARO
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Calculated load CHR_LOAD
Pelican can show this parameter as the engine load.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Catalyst temperature bank 2 sensor 1 CHR_CAT_T_BANK_2_SENS_1
- Service 22
DID 1F3D - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 2016 to 2026.
Catalyst temperature bank 2 sensor 2 CHR_CAT_T_BANK_2_SENS_2
- Service 22
DID 1F3F - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 2016 to 2026.
Catalyst temperature, bank 1 sensor 1 CHR_CAT_T_B1S1
- Service 21
PID 05 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Catalyst temperature, bank 1 sensor 2 CHR_CAT_T_B1S2
- Service 21
PID 05 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Catalyst temperature, bank 1 sensor 2, variant 2 CHR_CAT_T_B1S2_V2
- Service 21
PID 3E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2016 to 2026.
Check mode on CHR_CHECK_MODE_ON
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Closed throttle position switch on CHR_CLOSED_THROTTLE_POS_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 125 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Codes, include history CHR_CODES_INCLUDE
- Service 21
PID E1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Continuously variable transmission learning complete CHR_CVT_LEARNED
- Service 21
PID DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2016 to 2026.
Continuously variable transmission oil pressure CHR_CVT_OIL_P
- Service 21
PID BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 10200 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Coolant temperature CHR_COOL_TConfirmed
- Service 22
DID 1F05 - Module
7D2 → 7DA - Every
1 s - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x42 = 66 → = 26 °C
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
Coolant water route switching valve 1, closed? CHR_COOLANT_VALVE_1_CLOSEConfirmed
- Service 22
DID 282C - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Coolant water route switching valve 2, closed? CHR_COOLANT_VALVE_2_CLOSE
- Service 22
DID 2847 - Module
700 → 708 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Cooling fan duty ratio CHR_COOLING_FAN_DUTY_RATIO
- Service 22
DID 1046 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Cruise control on CHR_CRUISE_CTRL_ON
- Service 21
PID D3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Cylinder 1 injection volume CHR_CYL_1_INJ_VOLUME
- Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -640 to 15
- Unit
- Raw value
In testing for 2016 to 2026.
Cylinder 2 injection volume CHR_CYL_2_INJ_VOLUME
- Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -640 to 15
- Unit
- Raw value
In testing for 2016 to 2026.
Cylinder 3 injection volume CHR_CYL_3_INJ_VOLUME
- Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -640 to 15
- Unit
- Raw value
In testing for 2016 to 2026.
Cylinder 4 injection volume CHR_CYL_4_INJ_VOLUME
- Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -640 to 15
- Unit
- Raw value
In testing for 2016 to 2026.
Cylinder number CHR_CYLINDER_NUMBER
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Destination CHR_DESTINATION
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Dist battery cable disconnect CHR_DIST_BATT_CABLE
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2016 to 2026.
Electric fan motor on CHR_ELEC_FAN_MOTOR_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 34 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Electric thermostat duty ratio CHR_ELECTRIC_THERMOSTAT_DUTY_RATIO
- Service 22
DID 2829 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Electric water pump CHR_ELECTRIC_WATER_PUMPConfirmed
- Service 22
DID 2827 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 10200 rpm
- Unit
- rpm
0x38 = 56 → = 2,240 rpm
Confirmed for 2019, 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026.
Electric water pump RPM CHR_EWP_RPMConfirmed
- Service 22
DID 1043 - Module
700 → 708 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
0x00 = 0 → = 0 rpm
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Electric water pump target speed CHR_EWP_TARGET_VSSConfirmed
- Service 22
DID 1043 - Module
700 → 708 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
0x00 = 0 → = 0 rpm
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Engine coolant temperature CHR_ECTConfirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 21
PID 26 - Module
7C4 → 7CC - Every
5 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 1.3 to 90.55 °C
- Unit
- °C
0x2B = 43 → = 16.35 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Engine coolant temperature CHR_ECT_7C0Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 21
PID 23 - Module
7C0 → 7C8 - Every
5 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
0x00 = 0 → = 0 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Engine coolant temperature CHR_ECT_7E0
Pelican can show this parameter as the engine coolant temperature.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Engine coolant temperature, at ignition CHR_ECT_IGNConfirmed
- Service 22
DID 1041 - Module
700 → 708 - Every
5 s - Testing for 2016 to 2018, 2020 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119.375 °C
- Unit
- °C
0x99 = 153 → = 55.625 °C
Confirmed for 2019, 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026.
Engine coolant temperature, initial CHR_ECT_INITConfirmed
- Service 22
DID 1041 - Module
700 → 708 - Every
5 s - Testing for 2016 to 2018, 2020 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 119.375 °C
- Unit
- °C
0x86 = 134 → = 43.75 °C
Confirmed for 2019, 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026.
Engine independent CHR_ENG_INDEPENDENT
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 91 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Engine independent control CHR_ENG_INDEPENDENT_CTRL
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 88 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Engine oil pressure CHR_EOPConfirmed
- Service 22
DID 1074 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.92 kPa
- Unit
- kPa
0x0000 = 0 → = 0 kPa
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2019, 2022 to 2023, 2025.
Engine oil pressure control valve CHR_EOP_CONTROL_VALVEConfirmed
- Service 22
DID 2848 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4999.9207 mA
- Unit
- mA
0x051E = 1310 → = 99.945009 mA
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2019, 2023, 2025.
Engine oil temperature CHR_EOTConfirmed
Pelican can show this parameter as the engine oil temperature.
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x53 = 83 → = 43 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.
Engine oil temperature CHR_EOT_700
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 107B - Module
700 → 708 - Every
5 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.
Engine oil temperature, variation 2 CHR_EOT_V2Confirmed
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 1F5C - Module
700 → 708 - Every
5 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x53 = 83 → = 43 °C
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2019, 2023, 2025.
Engine run time, up to 255 sec. only CHR_ENG_RUN_TIME_UP_255
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 s
- Unit
- s
In testing for 2016 to 2026.
Engine stall control FB flow CHR_ENG_STALL_CTRL_FB
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 39.99
- Unit
- Number
In testing for 2016 to 2026.
Evaporative purge duty CHR_EVAP_PURGE_DUTY_7E0
- Service 21
PID 2E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2026.
Evaporative purge flow CHR_EVAP_PURGE_FLOW
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.99 %
- Unit
- %
In testing for 2016 to 2026.
Evaporative purge vacuum switching valve on CHR_EVAP_PURGE_VSV_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Exhaust gas recirculation step position CHR_EGR_STEP_POSITION
- Service 21
PID 47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Exhaust gas recirculation temperature CHR_EGR_T
- Service 21
PID ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 159 °C
- Unit
- °C
In testing for 2016 to 2026.
Exhaust gas recirculation valve step CHR_EGR_STEP
- Service 21
PID E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Exhaust VVT change angle, bank 1 CHR_EXHAUST_VVT_ANGLE_B1Confirmed
- Service 22
DID 1088 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
Exhaust VVT hold learn value, bank 1 CHR_EXHAUST_VVT_HOLD_LEARN_B1Confirmed
- Service 22
DID 1089 - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
0x1FF1 = 8177 → = 49.896732 %
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
Exhaust VVT oil control valve control duty CHR_EXHAUST_VVT_OCV_CONTROL_DUTYConfirmed
- Service 22
DID 1062 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 400 %
- Unit
- %
0x06EC = 1772 → = 10.815595 %
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2019, 2023, 2025.
Exhaust VVT target angle B1 CHR_EXHAUST_VVT_TARGET_ANGLE_B1Confirmed
- Service 22
DID 1071 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2019, 2023, 2025.
Exhaust VVT timing most over-advanced learn value, bank 1 CHR_EXHAUST_VVT_OVER_ADV_LEARN_B1Confirmed
- Service 22
DID 108F - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.99 °
- Unit
- °
0x245A = 9306 → = 90.878873 °
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
Front/rear motor torque ratio CHR_FRONT_REAR_MOTOR_TQ
- Service 22
DID 1039 - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -32.76 to 32.76
- Unit
- Number
In testing for 2019 to 2026.
Fuel cut for engine stop request CHR_F_C_ENG_STOP_REQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 92 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Fuel cut TAU on CHR_FC_TAU_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 127 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Fuel filter temperature CHR_FFT
- Service 22
DID 109A - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
G sensor calibration, complete CHR_G_SENS_CALIBRATION
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
G sensor learning value CHR_G_SENS_LEARNING
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2016 to 2026.
Generator inverter temperature CHR_GEN_INVERTER_T
- Service 22
DID 10A4 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Generator inverter temperature CHR_GEN_INVERTER_T_7D2
- Service 22
DID 10A8 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Generator inverter temperature after ignition on CHR_GEN_INVERTER_T_AFTER_ON
- Service 22
DID 10A8 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Glass humidity CHR_GLASS_HUMIDITY
- Service 21
PID B1 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2026.
Glass temperature CHR_GLASS_T
- Service 21
PID AF - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -557 to 621 °F
- Unit
- °F
In testing for 2016 to 2026.
Hydraulic valve, communication open CHR_HV_COMM_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Idle control CHR_IDLE_CTRL
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Idle spark advance control 1 CHR_IDLE_SPARK_ADVN_CTRL_1
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2016 to 2026.
Idle spark advance control 2 CHR_IDLE_SPARK_ADVN_CTRL_2
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2016 to 2026.
Idle spark advance control 3 CHR_IDLE_SPARK_ADVN_CTRL_3
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2016 to 2026.
Idle spark advance control 4 CHR_IDLE_SPARK_ADVN_CTRL_4
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2016 to 2026.
Idle spark advance control, cylinder 1 CHR_IDLE_SAC_CYL_1Confirmed
- Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.9375 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Idle spark advance control, cylinder 2 CHR_IDLE_SAC_CYL_2Confirmed
- Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.9375 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Idle spark advance control, cylinder 3 CHR_IDLE_SAC_CYL_3Confirmed
- Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.9375 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Idle spark advance control, cylinder 4 CHR_IDLE_SAC_CYL_4Confirmed
- Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.9375 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Idle speed control learning CHR_IDLE_SPD_CTRL
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 93 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Idle speed control learning value, l/s CHR_IDLE_SPD_CTRL_L_S
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99
- Unit
- Number
In testing for 2016 to 2026.
IG OFF elapsed time CHR_IG_OFF_ELAPSED_TIME
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 min
- Unit
- min
In testing for 2016 to 2026.
Ignition advance CHR_SPARKADV_21
- Service 21
PID 0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2016 to 2026.
Ignition timing advance CHR_IGN_ADVANCE
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Immobilizer communication on CHR_IMMOBILIZER_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 120 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Initial engine coolant temperature CHR_INITIAL_ECT
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119.3
- Unit
- Number
In testing for 2016 to 2026.
Initial intake air temperature CHR_INITIAL_IAT
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2016 to 2026.
Injection CHR_INJECTION
- Service 22
DID 1019 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | DIRECT | Direct |
2 | BOTH | Both |
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Supported for 2024. Not supported for 2019.
Injection duration for cylinder 1 CHR_INJ_DUR_CYL_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2016 to 2026.
Injection feedback value 1 CHR_INJ_FEEDBACK_1
- Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -20 to 15
- Unit
- Raw value
In testing for 2016 to 2026.
Injection feedback value 1 CHR_INJ_FEEDBACK_1_700
- Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 2016 to 2026.
Injection feedback value 2 CHR_INJ_FEEDBACK_2
- Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -20 to 15
- Unit
- Raw value
In testing for 2016 to 2026.
Injection feedback value 2 CHR_INJ_FEEDBACK_2_700
- Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 2016 to 2026.
Injection feedback value 3 CHR_INJ_FEEDBACK_3
- Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -20 to 15
- Unit
- Raw value
In testing for 2016 to 2026.
Injection feedback value 3 CHR_INJ_FEEDBACK_3_700
- Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 2016 to 2026.
Injection feedback value 4 CHR_INJ_FEEDBACK_4
- Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -20 to 15
- Unit
- Raw value
In testing for 2016 to 2026.
Injection feedback value 4 CHR_INJ_FEEDBACK_4_700
- Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 2016 to 2026.
Injection feedback value 5 CHR_INJ_FEEDBACK_5
- Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 2016 to 2026.
Injection feedback value 6 CHR_INJ_FEEDBACK_6
- Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 2016 to 2026.
Injection volume CHR_INJ_VOLConfirmed
- Service 22
DID 1017 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 20 L
- Unit
- L
0x0000 = 0 → = 0 L
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Injection volume - target CHR_INJ_VOLUME_TGT
- Service 22
DID 112C - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15
- Unit
- Raw value
In testing for 2016 to 2026.
Injection volume 1 CHR_INJ_VOLUME_1
- Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 300
- Unit
- Raw value
In testing for 2016 to 2026.
Injection volume 2 CHR_INJ_VOLUME_2
- Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 300
- Unit
- Raw value
In testing for 2016 to 2026.
Injection volume 3 CHR_INJ_VOLUME_3
- Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 300
- Unit
- Raw value
In testing for 2016 to 2026.
Injection volume 5 CHR_INJ_VOLUME_5
- Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 300
- Unit
- Raw value
In testing for 2016 to 2026.
Injection volume 6 CHR_INJ_VOLUME_6
- Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- -40 to 300
- Unit
- Raw value
In testing for 2016 to 2026.
Injection volume per 10 injections, cylinder 1 CHR_INJ_VOL_CYL_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.002 L
- Unit
- L
In testing for 2016 to 2026.
Injection volume total CHR_INJ_VOLUME_TOT
- Service 22
DID 112F - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -640 to 15
- Unit
- Raw value
In testing for 2016 to 2026.
Injector port CHR_INJECTOR_PORTConfirmed
- Service 22
DID 1018 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2019, 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026.
Injector pulse width CHR_INJ_PW
- Service 21
PID E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.6 ms
- Unit
- ms
In testing for 2016 to 2026.
Injector pulse width CHR_INJ_WIDTH
- Service 21
PID F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.64 ms
- Unit
- ms
In testing for 2016 to 2026.
Input shaft speed CHR_SPD_NIN
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Intake air temperature CHR_IAT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Intake air temperature CHR_IAT_21
- Service 21
PID 0F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Intake air temperature, bank 1 sensor 1 CHR_IAT_B1S1
- Service 22
DID 1F77 - Module
700 → 708 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Intake air temperature, bank 1 sensor 2 CHR_IAT_B1S2
- Service 22
DID 1F77 - Module
700 → 708 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Intake VVT change angle, bank 1 CHR_INTAKE_VVT_CHANGE_ANGLE_BANK_1Confirmed
- Service 22
DID 1087 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Intake VVT most over-retarded learn value, bank 1 CHR_INTAKE_VVT_OVER_RET_LEARN_B1Confirmed
- Service 22
DID 108D - Module
700 → 708 - Every
3600 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.99 °
- Unit
- °
0x0D48 = 3400 → = 33.203113 °
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
Intake VVT target angle B1 CHR_INTAKE_VVT_TARGET_ANGLE_B1Confirmed
- Service 22
DID 106F - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Integrated engine run time CHR_INTEGRATED_ENG_RUN
- Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 h
- Unit
- h
In testing for 2016 to 2026.
Intercooler coolant temperature CHR_INTERCOOLER_ECT
- Service 22
DID 119C - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Intercooler water pump CHR_INTERCOOLER_WATER
- Service 22
DID 2820 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 %
- Unit
- %
In testing for 2016 to 2026.
Internal temperature CHR_ECU_INTERNAL_TConfirmed
- Service 22
DID 105E - Module
700 → 708 - Every
5 s - Testing for 2016 to 2023, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x46 = 70 → = 30 °C
Confirmed for 2024 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2019, 2023.
Inverter coolant temperature CHR_INVRT_COOLANT_TConfirmed
- Service 22
DID 10B2 - Module
7D2 → 7DA - Every
1 s - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 °C
- Unit
- °C
0x42 = 66 → = 26 °C
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
Inverter water pump duty CHR_INVERTER_WATER_PMP
- Service 22
DID 1112 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 199 %
- Unit
- %
In testing for 2019 to 2026.
Judge time engine ignition CHR_JUDGE_TIME_ENG_IGN
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2016 to 2026.
Judge time engine output CHR_JUDGE_TIME_ENG
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2016 to 2026.
Key cycle CHR_KEY_CYCLE
- Service 22
DID 0102 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Knock adjust CHR_KNOCK_ADJUST
- Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -64 to 1984 °
- Unit
- °
In testing for 2016 to 2026.
Knock adjust CHR_KNOCK_ADJUST_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1024 °
- Unit
- °
In testing for 2016 to 2026.
Knock correct learn value CHR_KNOCK_CORRECT_LEARN
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1023 °
- Unit
- °
In testing for 2016 to 2026.
Knock correction, learned value CHR_KNOCK_CORRECT_LEARNED_VALUEConfirmed
- Service 22
DID 105C - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1023
- Unit
- Number
0x81B1 = 33201 → = 13.53125
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Knock feedback CHR_KNOCK_FEEDBACK
- Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -64 to 1984 °
- Unit
- °
In testing for 2016 to 2026.
Knock feedback CHR_KNOCK_FEEDBACK_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1024 °
- Unit
- °
In testing for 2016 to 2026.
Knock feedback value CHR_KNOCK_FEEDBACK_VALUEConfirmed
- Service 22
DID 105C - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1023
- Unit
- Number
0x7FA0 = 32672 → = -3
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Long term fuel trim, bank 1 CHR_LONG_FT_B1
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Long term fuel trim, bank 2 CHR_LONG_FT_B2
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Long-term fuel trim, bank 1 CHR_LTFT1_21
- Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.15 %
- Unit
- %
In testing for 2016 to 2026.
Mass air flow CHR_MAF
Pelican can show this parameter as the mass air flow.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Mass air flow CHR_MAF_21
- Service 21
PID 10 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 g/s
- Unit
- g/s
In testing for 2016 to 2026.
Master cylinder open CHR_MASTER_CYLINDER_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Master cylinder sensor temperature CHR_MASTER_CYL_TEMP
- Service 22
DID 1006 - Module
7B0 → 7B8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -20 to 100 °C
- Unit
- °C
In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2019, 2022 to 2025.
Maximum generator inverter temperature CHR_MAX_GEN_INVERTER_T
- Service 22
DID 10A8 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Maximum motor inverter temperature CHR_MAX_MOTOR_INVERTER_T
- Service 22
DID 10A5 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Misfire count, all cylinders CHR_MISFIRE_CNTConfirmed
- Service 22
DID 10A5 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Misfire count, cylinder 1 CHR_MISFIRE_CYL1Confirmed
- Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Misfire count, cylinder 2 CHR_MISFIRE_CYL2Confirmed
- Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Misfire count, cylinder 3 CHR_MISFIRE_CYL3Confirmed
- Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Misfire count, cylinder 4 CHR_MISFIRE_CYL4Confirmed
- Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Misfire load CHR_MISFIRE_LOADConfirmed
- Service 22
DID 10AA - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Misfire margin CHR_MISFIRE_MARGIN
- Service 22
DID 10AA - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 rpm
- Unit
- rpm
In testing for 2016 to 2018, 2020 to 2022, 2026. Supported for 2019, 2023 to 2025.
Misfire RPM CHR_MISFIRE_RPM
- Service 22
DID 10AA - Module
700 → 708 - Every
1 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2016 to 2018, 2020 to 2022, 2026. Supported for 2019, 2023 to 2025.
Misfire RPM CHR_MISFIRE_RPM_7E0
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Misfire test result, incomplete CHR_MIS_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Model year CHR_MODEL_YEAR
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 1900 to 2155
- Unit
- Number
In testing for 2016 to 2026.
Motor inverter temperature CHR_MOTOR_INVERTER_T
- Service 22
DID 10A5 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Motor inverter temperature after ignition on CHR_MOTOR_INVERTER_T_ON
- Service 22
DID 10A5 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Motor inverter, maximum temperature CHR_M_INVRT_MAX_T
- Service 22
DID 10A6 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.
Motor regenerative brake torque CHR_MOTOR_REGENERATIVE_BREAK
- Service 22
DID 1069 - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 kW
- Unit
- kW
In testing for 2019 to 2026.
Motor regenerative brake torque, requested CHR_MOTOR_REGENERATIVE
- Service 22
DID 1069 - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 kW
- Unit
- kW
In testing for 2019 to 2026.
Motor RPM CHR_RPMConfirmed
- Service 22
DID 10A1 - Module
7D2 → 7DA - Every
250 ms - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
0x8000 = 32768 → = 0 rpm
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
Motor torque CHR_TQConfirmed
- Service 22
DID 10A1 - Module
7D2 → 7DA - Every
250 ms - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 N·m
- Unit
- N·m
0x7FFE = 32766 → = -0.25 N·m
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
O2 heater b1s2_active CHR_O2_HEATER_B1S2
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 68 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
O2 heater current val bank 1 sensor 2 CHR_O2_HEATER_CURR_VAL
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 A
- Unit
- A
In testing for 2016 to 2026.
Open side malfunction on CHR_OPEN_SIDE_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 145 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Output shaft speed CHR_SPD_NOUT
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2016 to 2026.
OXS1, A/FS2 test result, incomplete CHR_OXS1_FS2_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Oxygen sensor voltage, bank 1 sensor 1 CHR_O2S11_V
- Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.27 V
- Unit
- V
In testing for 2016 to 2026.
Oxygen sensor voltage, bank 1 sensor 2 CHR_O2S_B1S2
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
PM accumulation ratio - bank 1 CHR_PM_ACCUMULATION_RAT_1
- Service 22
DID 1105 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 15 %
- Unit
- %
In testing for 2016 to 2026.
Purge cut vacuum switching valve duty CHR_PURGE_CUT_VSV_DUTY
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2016 to 2026.
Racing operation CHR_RACING_OPERATION
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 90 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Rear motor inverter, coolant temperature CHR_RM_INVRT_COOL_T
- Service 22
DID 10A6 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.
Rear motor regenerative brake torque CHR_REAR_MOTOR_REGENERATIVE
- Service 22
DID 106A - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 kW
- Unit
- kW
In testing for 2019 to 2026.
Rear motor regenerative brake torque, requested CHR_REAR_MOTOR
- Service 22
DID 106A - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 kW
- Unit
- kW
In testing for 2019 to 2026.
Rear motor speed CHR_RM_TQ_REQ
- Service 22
DID 10A2 - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.
Rear motor torque CHR_RM_TQ
- Service 22
DID 10A2 - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 N·m
- Unit
- N·m
In testing for 2020 to 2022, 2026. Not supported for 2019, 2023 to 2025.
Regulator pressure CHR_REGULATOR_PConfirmed
- Service 21
PID 53 - Module
7C4 → 7CC - Every
5 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -456.68 to 3294 kPa
- Unit
- kPa
0x33 = 51 → = 293.53 kPa
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Request engine run time CHR_REQ_ENG_RUN_TIME
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2016 to 2026.
Request warm-up CHR_REQ_WARM_UP
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 89 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Requested engine torque CHR_REQ_ENG_TQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383
- Unit
- Number
In testing for 2016 to 2026.
Rough idle, cylinder 1 CHR_ROUGH_IDLE_CYL_1
- Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Rough idle, cylinder 2 CHR_ROUGH_IDLE_CYL_2
- Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Rough idle, cylinder 3 CHR_ROUGH_IDLE_CYL_3
- Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Rough idle, cylinder 4 CHR_ROUGH_IDLE_CYL_4
- Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Short term fuel trim, bank 1 CHR_SHORT_FT_B1
Pelican can show this parameter as the short term fuel trim.
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Short term fuel trim, bank 2 CHR_SHORT_FT_B2
Pelican can show this parameter as the short term fuel trim.
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Starter relay on CHR_STARTER_RELAY_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 47 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Stroke open CHR_STROKE_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
System guard on CHR_SYSTEM_GUARD_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 144 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Throttle fully close learn CHR_THROTTLE_FULLY_CLOSE
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2016 to 2026.
Throttle idle position on CHR_THROTTLE_IDLE_POS_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 149 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Throttle motor current CHR_THROTTLE_MOTOR
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 19.9 A
- Unit
- A
In testing for 2016 to 2026.
Throttle motor duty, close CHR_THROTTLE_MOTOR_DUTY_CLOSE
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2016 to 2026.
Throttle motor duty, open CHR_THROTTLE_MOTOR_DUTY_OPEN
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2016 to 2026.
Throttle position CHR_THROTTLE_21
- Service 21
PID 11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2026.
Throttle position command CHR_THROTTLE_POS_COMMAND
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2016 to 2026.
Throttle position, number 1 CHR_THROTTLE_POS_NUMBER_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2016 to 2026.
Throttle position, number 2 CHR_THROTTLE_POS_NUMBER_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2016 to 2026.
Throttle require position CHR_THROTTLE_REQUIRE_POS
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2016 to 2026.
Throttle sensor open position 1 CHR_THROTTLE_SENS_OPEN_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2016 to 2026.
Throttle sensor open position 2 CHR_THROTTLE_SENS_OPEN_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2016 to 2026.
Total fuel trim, bank 1 CHR_TOT_FT_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -50 to 49.6 %
- Unit
- %
In testing for 2016 to 2026.
Transaxle oil temperature CHR_TRANSAXLE_OIL_TConfirmed
- Service 22
DID 1040 - Module
7D2 → 7DA - Every
1 s - Testing for 2020 to 2022, 2024 to 2026
Example reply from a 2023 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x4D = 77 → = 37 °C
Confirmed for 2019, 2023. In testing for 2020 to 2022, 2026. Not supported for 2024 to 2025.
Transmission fluid temperature CHR_ATF_TEMP_700
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1638 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2019, 2022 to 2025.
Transmission output shaft speed CHR_TRANS_OUT_RPM
- Service 21
PID BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Turbine speed CHR_SPD_NT
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Valvematic current angle CHR_VALVEMATIC_CURRENT
- Service 21
PID 31 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
In testing for 2016 to 2026.
Valvematic, target angle CHR_VALVEMATIC_TGT_ANG
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
In testing for 2016 to 2026.
Variable valve timing aim angle 1 CHR_VARIABLE_VLV_TIM_AIM_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2016 to 2026.
Variable valve timing change angle 1 CHR_VARIABLE_VLV_TIM_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 639 °
- Unit
- °
In testing for 2016 to 2026.
Variable valve timing control status 1 on CHR_VARIABLE_VLV_TIM_1_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Variable valve timing oil control valve duty 1 CHR_VARIABLE_VLV_TIM_OIL_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2016 to 2026.
Variable valve timing oil temperature CHR_VVTOTConfirmed
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x6A = 106 → = 66 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.
Variable valve timing opening angle bank 1 CHR_VVT_IE_OPENING_ANGLE_BANK_1Confirmed
- Service 22
DID 2843 - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
0x00 = 0 → 0 %
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
Vehicle speed CHR_VSS_21
- Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2016 to 2026.
Vehicle speed sensor test result, incomplete CHR_SPD_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Catalyst
Catalyst temperature, bank 1 sensor 1 CHR_CAT_T_11Confirmed
- Service 22
DID 1F3C - Module
700 → 708 - Every
5 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x0446 = 1094 → = 69.4 °C
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Catalyst temperature, bank 1 sensor 2 CHR_CAT_T_12Confirmed
- Service 22
DID 1F3E - Module
700 → 708 - Every
5 s - Testing for 2016 to 2018, 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x02D7 = 727 → = 32.7 °C
Confirmed for 2019, 2023 to 2025. In testing for 2016 to 2018, 2020 to 2022, 2026.
Misfires
All cylinders misfire count CHR_ALL_CYLINDERS_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Cylinder #1 misfire count CHR_CYL1_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Cylinder #2 misfire count CHR_CYL2_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Cylinder #3 misfire count CHR_CYL3_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Cylinder #4 misfire count CHR_CYL4_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Misfire load CHR_MISFIRE_LOAD_7E0
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.98
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Misfire margin CHR_MISFIRE_MARGIN_7E0
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 %
- Unit
- %
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Fluids
Distance since oil change CHR_OIL_CHANGE_ODO
- Service 21
PID 41 - Module
7C0 → 7C8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 41038.272 km
- Unit
- km
In testing for 2016 to 2018, 2020 to 2026. Not supported for 2019.
Fuel
Engine fuel rate CHR_ENG_FUEL_RATE
- Service 22
DID F19D - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
In testing for 2016 to 2026.
Fuel cut CHR_FUEL_CUT
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Fuel cut CHR_FUEL_CUT_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 121 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Fuel cut time CHR_FUEL_CUT_TIME
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 68734.9511
- Unit
- Number
In testing for 2016 to 2026.
Fuel injection timing CHR_FUEL_INJ_TIM
- Service 21
PID F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.64 ms
- Unit
- ms
In testing for 2016 to 2026.
Fuel level CHR_FLI
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 1F2F - Module
700 → 708 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2019, 2022 to 2025.
Fuel level CHR_FUEL_LEVELConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 1022 - Module
7C0 → 7C8 - Every
30 s - Testing for 2016 to 2023, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
0x0569 = 1385 → = 13.85 L
Confirmed for 2024 to 2025. In testing for 2016 to 2018, 2020 to 2023, 2026. Not supported for 2019.
Fuel level, volume CHR_FLI_VOLConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 21
PID 29 - Module
7C0 → 7C8 - Every
5 s - Testing for 2016 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 21 gal
- Unit
- gal
0x16 = 22 → = 2.906209 gal
Confirmed for 2019, 2022 to 2023. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2024 to 2025.
Fuel pressure 1 CHR_FUEL_P_1
- Service 22
DID 113C - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 50000 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Fuel pressure 1 CHR_FUEL_P_1_700
- Service 22
DID 11C4 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Fuel pressure 2 CHR_FUEL_P_2
- Service 22
DID 113C - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 50000 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Fuel pressure 2 CHR_FUEL_P_2_700
- Service 22
DID 11C4 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Fuel pressure 3 CHR_FUEL_P_3
- Service 22
DID 113C - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 50000 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Fuel pressure 3 CHR_FUEL_P_3_700
- Service 22
DID 11C4 - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Fuel pressure 4 CHR_FUEL_P_4
- Service 22
DID 113C - Module
700 → 708 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 50000 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Fuel pressure 4 CHR_FUEL_P_4_700
- Service 22
DID 11C4 - Module
700 → 708 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Fuel pressure 5 CHR_FUEL_P_5
- Service 22
DID 11C4 - Module
700 → 708 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Fuel pressure 6 CHR_FUEL_P_6
- Service 22
DID 11C4 - Module
700 → 708 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Fuel pump duty ratio CHR_FUEL_PUMP_DUTY_RATIOConfirmed
- Service 22
DID 106A - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3996 kPa
- Unit
- kPa
0x01EC = 492 → = 30 kPa
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
Fuel pump/speed status on CHR_FUEL_PMP_SPD_STAT_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Fuel return temperature CHR_FUEL_RETURN_T
- Service 22
DID 1141 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Fuel temperature 1 CHR_FUEL_T_1
- Service 22
DID 113E - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Fuel temperature 1 CHR_FUEL_T_1_700
- Service 22
DID 11C5 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Fuel temperature 2 CHR_FUEL_T_2
- Service 22
DID 113E - Module
700 → 708 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Fuel temperature 2 CHR_FUEL_T_2_700
- Service 22
DID 11C5 - Module
700 → 708 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Fuel temperature 3 CHR_FUEL_T_3
- Service 22
DID 113E - Module
700 → 708 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Fuel temperature 3 CHR_FUEL_T_3_700
- Service 22
DID 11C5 - Module
700 → 708 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Fuel temperature 4 CHR_FUEL_T_4
- Service 22
DID 113E - Module
700 → 708 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Fuel temperature 4 CHR_FUEL_T_4_700
- Service 22
DID 11C5 - Module
700 → 708 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Fuel temperature 5 CHR_FUEL_T_5
- Service 22
DID 11C5 - Module
700 → 708 - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Fuel temperature 6 CHR_FUEL_T_6
- Service 22
DID 11C5 - Module
700 → 708 - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
High fuel pressure, actual CHR_HFP_ACTUALConfirmed
- Service 22
DID 1F6D - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
0x047E = 1150 → = 11,500 kPa
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
High fuel pressure, target CHR_HFP_TARGETConfirmed
- Service 22
DID 1F6D - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
0x07D0 = 2000 → = 20,000 kPa
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
Low fuel pressure CHR_LFPConfirmed
- Service 22
DID 10CD - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.7 kPa
- Unit
- kPa
0x954D = 38221 → = 545.3 kPa
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2019, 2022 to 2023, 2025.
Low fuel pressure CHR_LOW_FUEL_PRESSUREConfirmed
- Service 22
DID 1F6D - Module
700 → 708 - Every
1 s - Testing for 2016 to 2023, 2025 to 2026
Example reply from a 2024 Toyota C-HR+.
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
0x0036 = 54 → = 540 kPa
Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.
Target air-fuel equivalence ratio CHR_LAMBDA_TARGET
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Vehicle fuel rate CHR_VEH_FUEL_RATE
- Service 22
DID F19D - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
In testing for 2016 to 2026.
Lights
Check engine SW CHR_CHECK_ENGINE_LIGHTConfirmed
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Hazard switch history CHR_HAZARD_SWITCH_HISTORYConfirmed
- Service 21
PID BC - Module
7B0 → 7B8 - Every
3600 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 2 of the reply.
- Unit
- Named states
0b0 = 0 → INCOMPLETE
| Raw value | State | Meaning |
|---|---|---|
0 | INCOMPLETE | Incomplete |
1 | COMPLETE | Complete |
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2026.
Oil pressure switch CHR_EOP_LIGHTConfirmed
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 35 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
P-seatbelt buckle SW CHR_P_SEATBELT_BUCKLE_LIGHTConfirmed
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rheostat CHR_RHEOSTAT
Higher values are brighter
- Service 21
PID 68 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2026. Not supported for 2019.
Stop light CHR_STOP_LIGHT_SWConfirmed
- Service 21
PID 1F - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Stop light CHR_STOP_LIGHT_SWITCH
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Stop light relay CHR_STOP_LIGHT_RELAYConfirmed
- Service 21
PID 3C - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Tail cancel SW CHR_TAIL_CANCEL_LIGHTConfirmed
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b1 = 1 → 1
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Movement
Accelerator fully close learn 1 CHR_ACCEL_FULLY_CLOSE_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 124.5 °
- Unit
- °
In testing for 2016 to 2026.
Accelerator fully close learn 2 CHR_ACCEL_FULLY_CLOSE_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 124.5 °
- Unit
- °
In testing for 2016 to 2026.
Accelerator idle position on CHR_ACCEL_IDLE_POS_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 148 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Accelerator position CHR_ACCEL_POS
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2016 to 2026.
Accelerator sensor out, number 1 CHR_ACCEL_SENS_OUT_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2016 to 2026.
Accelerator sensor out, number 2 CHR_ACCEL_SENS_OUT_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2016 to 2026.
Average engine speed of all cylinders CHR_AV_RPM_ALL_CYL
Pelican can show this parameter as the engine speed.
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Compressor speed CHR_COMP_SPD
- Service 21
PID 49 - Module
7C4 → 7CC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Compressor, target speed CHR_COMP_TGT_SPD
- Service 21
PID 4A - Module
7C4 → 7CC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Cruise control speed CHR_CRUISE_CTRL_SPD
- Service 21
PID D3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2016 to 2026.
Engine speed CHR_RPM_7E0
Pelican can show this parameter as the engine speed.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Engine speed of cylinder 1 CHR_RPM_CYL_1
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Engine speed of cylinder 2 CHR_RPM_CYL_2
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Engine speed of cylinder 3 CHR_RPM_CYL_3
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Engine speed of cylinder 4 CHR_RPM_CYL_4
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Front left wheel acceleration CHR_FL_WHEEL_ACCELERATIONConfirmed
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
0x00 = 0 → = 0 m/s²
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front left wheel speed CHR_FL_WHEEL_VSSConfirmed
- Service 22
DID 1075 - Module
7D2 → 7DA - Every
100 ms - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 km/h
- Unit
- km/h
0x8000 = 32768 → = 0 km/h
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
Front left wheel speed CHR_TIRE_FL_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2019, 2022 to 2023. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2024 to 2025.
Front left wheel speed? CHR_FL_WHEEL_SPEED_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front right wheel acceleration CHR_FR_WHEEL_ACCELERATIONConfirmed
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
0x00 = 0 → = 0 m/s²
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front right wheel speed CHR_FR_WHEEL_VSSConfirmed
- Service 22
DID 1075 - Module
7D2 → 7DA - Every
100 ms - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 km/h
- Unit
- km/h
0x8000 = 32768 → = 0 km/h
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
Front right wheel speed CHR_TIRE_FR_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2019, 2022 to 2023. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2024 to 2025.
Front right wheel speed? CHR_FR_WHEEL_SPEED_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
High voltage, target engine speed CHR_HIGH_V_TGT_RPM
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Intercooler water pump speed, raw count CHR_IWP_SPEED
- Service 22
DID 1075 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Minimum engine speed CHR_MIN_RPM
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Rear left wheel acceleration CHR_RL_WHEEL_ACCELERATIONConfirmed
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 24 to 31 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
0x00 = 0 → = 0 m/s²
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear left wheel speed CHR_RL_WHEEL_VSSConfirmed
- Service 22
DID 1075 - Module
7D2 → 7DA - Every
100 ms - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 km/h
- Unit
- km/h
0x8000 = 32768 → = 0 km/h
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
Rear left wheel speed CHR_TIRE_RL_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota C-HR+.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2019, 2022 to 2023. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2024 to 2025.
Rear left wheel speed? CHR_RL_WHEEL_SPEED_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear right wheel acceleration CHR_RR_WHEEL_ACCELERATIONConfirmed
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
0x00 = 0 → = 0 m/s²
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear right wheel speed CHR_RR_WHEEL_VSSConfirmed
- Service 22
DID 1075 - Module
7D2 → 7DA - Every
100 ms - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 km/h
- Unit
- km/h
0x8000 = 32768 → = 0 km/h
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
Rear right wheel speed CHR_TIRE_RR_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2019, 2022 to 2023. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2024 to 2025.
Rear right wheel speed? CHR_RR_WHEEL_SPEED_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Speed CHR_VSS_7C0Confirmed
Pelican can show this parameter as the speed.
- Service 21
PID 21 - Module
7C0 → 7C8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Vehicle speed CHR_VSSConfirmed
Current vehicle speed.
Pelican can show this parameter as the speed.
- Service 21
PID 21 - Module
7B0 → 7B8 - Every
200 ms - Testing for 2016 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 323.85 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2019, 2022 to 2023. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2024 to 2025.
Vehicle speed CHR_VSS_7E0
Pelican can show this parameter as the speed.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Vehicle speed CHR_VSS_V2Confirmed
Pelican can show this parameter as the speed.
- Service 22
DID 1F0D - Module
7D2 → 7DA - Every
250 ms - Testing for 2020 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2019, 2022 to 2025. In testing for 2020 to 2021, 2026.
Orientation
Deceleration CHR_DECELConfirmed
- Service 21
PID 05 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -18.18 to 18.18 m/s²
- Unit
- m/s²
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Deceleration 2 CHR_DECEL_2Confirmed
- Service 21
PID 05 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -18.18 to 18.18 m/s²
- Unit
- m/s²
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Deceleration open CHR_DECELERATION_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Lateral g CHR_LAT_GConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.5 to 2.5 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2019, 2022 to 2023. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2024 to 2025.
Longitudinal g CHR_LNG_GConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.5 to 2.5 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2019, 2022 to 2023. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2024 to 2025.
Yaw rate value, degrees/sec CHR_YAW_RATEConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2021, 2024 to 2026
Example reply from a 2023 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 °
- Unit
- °
0x80 = 128 → = 0 °
Confirmed for 2019, 2022 to 2023. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2024 to 2025.
Yaw rate, error? CHR_YAW_RATE_OPEN_ERRORConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Yaw rate, sensor 1 CHR_YAW_1Confirmed
- Service 21
PID 06 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
0x63 = 99 → = -29
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Yaw rate, sensor 2 CHR_YAW_2Confirmed
- Service 21
PID 06 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
0x63 = 99 → = -29
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Zero point of deceleration CHR_ZP_DECConfirmed
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.56 to 2.54 g
- Unit
- g
0xFF = -1 → = -0.02 g
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Zero point of deceleration 2 CHR_ZP_DEC2Confirmed
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.56 to 2.54 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Zero point of yaw rate CHR_ZERO_POINT_OF_YAW_RATE
- Service 21
PID A1 - Module
7B0 → 7B8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2026. Not supported for 2019.
Zero point of yaw rate, degrees/sec CHR_ZP_YAWConfirmed
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
0x80 = 128 → = 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Seatbelts
Buckle switch, left side CHR_BUCKLE_LS
- Service 21
PID 04 - Module
780 → 788 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Supported for 2019. Not supported for 2024.
Buckle switch, right side CHR_BUCKLE_RS
- Service 21
PID 04 - Module
780 → 788 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Supported for 2019. Not supported for 2024.
Reverse beep CHR_REVERSE_BEEP
- Service 21
PID AC - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- On or off
In testing for 2016 to 2018, 2020 to 2026. Not supported for 2019.
Seat belt beep, driver CHR_SEAT_BELT_BEEP_DRIVERConfirmed
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Seat belt beep, passenger CHR_SEAT_BELT_BEEP_PASSENGERConfirmed
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Seat belt beep, reminder CHR_SEAT_BELT_BEEP_REMINDERConfirmed
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Tires
Brake assist status CHR_BA_CTRL_STATUSConfirmed
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front left tire pressure CHR_TP_3Confirmed
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 1005 - Module
750 → 758 - Every
15 s - Testing for 2016 to 2023, 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 56.1212 psi
- Unit
- psi
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2019, 2022 to 2023.
Front left tire pressure CHR_TP_FLConfirmed
Pelican can show this parameter as the front left tire pressure.
- Service 21
PID 30 - Module
750 → 758 - Every
2.5 s - Testing for 2016 to 2018, 2020 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.896 bar
- Unit
- bar
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front left tire temperature CHR_TT_3Confirmed
- Service 22
DID 1004 - Module
750 → 758 - Every
15 s - Testing for 2016 to 2023, 2026
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -30 to 100 °C
- Unit
- °C
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2019, 2022 to 2023.
Front left tire temperature CHR_TT_FLConfirmed
Pelican can show this parameter as the front left tire temperature.
- Service 21
PID 16 - Module
750 → 758 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x3D = 61 → = 21 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Front left wheel ABS status CHR_FL_WHEEL_ABS_CTRLConfirmed
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front left wheel vehicle stability control status CHR_FL_WHEEL_VSC_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front right tire pressure CHR_TP_1Confirmed
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 1005 - Module
750 → 758 - Every
15 s - Testing for 2016 to 2023, 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 56.1212 psi
- Unit
- psi
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2019, 2022 to 2023.
Front right tire pressure CHR_TP_FRConfirmed
Pelican can show this parameter as the front right tire pressure.
- Service 21
PID 30 - Module
750 → 758 - Every
2.5 s - Testing for 2016 to 2018, 2020 to 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.896 bar
- Unit
- bar
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front right tire temperature CHR_TT_1Confirmed
- Service 22
DID 1004 - Module
750 → 758 - Every
15 s - Testing for 2016 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -30 to 100 °C
- Unit
- °C
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2019, 2022 to 2023.
Front right tire temperature CHR_TT_FRConfirmed
Pelican can show this parameter as the front right tire temperature.
- Service 21
PID 16 - Module
750 → 758 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x33 = 51 → = 11 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Front right wheel ABS status CHR_FR_WHEEL_ABS_CTRLConfirmed
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front right wheel cylinder open CHR_FR_WHEEL_CYLINDER_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front right wheel vehicle stability control status CHR_FR_WHEEL_VSC_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Predictive brake assist status CHR_PBA_CTRL_STATUSConfirmed
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear left tire pressure CHR_TP_4Confirmed
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 1005 - Module
750 → 758 - Every
15 s - Testing for 2016 to 2023, 2026
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 56.1212 psi
- Unit
- psi
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2019, 2022 to 2023.
Rear left tire pressure CHR_TP_RLConfirmed
Pelican can show this parameter as the rear left tire pressure.
- Service 21
PID 30 - Module
750 → 758 - Every
2.5 s - Testing for 2016 to 2018, 2020 to 2026
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.896 bar
- Unit
- bar
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear left tire temperature CHR_TT_4Confirmed
- Service 22
DID 1004 - Module
750 → 758 - Every
15 s - Testing for 2016 to 2023, 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -30 to 100 °C
- Unit
- °C
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2019, 2022 to 2023.
Rear left tire temperature CHR_TT_RLConfirmed
Pelican can show this parameter as the rear left tire temperature.
- Service 21
PID 16 - Module
750 → 758 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x34 = 52 → = 12 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Rear left wheel ABS status CHR_RL_WHEEL_ABS_CTRLConfirmed
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear left wheel EBS status CHR_RL_WHEEL_EBD_CTRLConfirmed
Electronic brakeforce distribution
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear left wheel vehicle stability control status CHR_RL_WHEEL_VSC_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear right tire pressure CHR_TP_2Confirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 1005 - Module
750 → 758 - Every
15 s - Testing for 2016 to 2023, 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 56.1212 psi
- Unit
- psi
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2019, 2022 to 2023.
Rear right tire pressure CHR_TP_RRConfirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 21
PID 30 - Module
750 → 758 - Every
2.5 s - Testing for 2016 to 2018, 2020 to 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.896 bar
- Unit
- bar
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear right tire temperature CHR_TT_2Confirmed
- Service 22
DID 1004 - Module
750 → 758 - Every
15 s - Testing for 2016 to 2023, 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -30 to 100 °C
- Unit
- °C
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2019, 2022 to 2023.
Rear right tire temperature CHR_TT_RRConfirmed
Pelican can show this parameter as the rear right tire temperature.
- Service 21
PID 16 - Module
750 → 758 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x34 = 52 → = 12 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2022, 2026. Not supported for 2023 to 2025.
Rear right wheel ABS status CHR_RR_WHEEL_ABS_CTRLConfirmed
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear right wheel EBS status CHR_RR_WHEEL_EBD_CTRLConfirmed
Electronic brakeforce distribution
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear right wheel vehicle stability control status CHR_RR_WHEEL_VSC_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Spare tire pressure CHR_TP_5Confirmed
- Service 22
DID 1005 - Module
750 → 758 - Every
15 s - Testing for 2016 to 2023, 2026
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 56.1212 psi
- Unit
- psi
Confirmed for 2025. In testing for 2026. Supported for 2024. Not supported for 2019, 2022 to 2023.
Spare tire pressure CHR_TP_SPAREConfirmed
- Service 21
PID 30 - Module
750 → 758 - Every
2.5 s - Testing for 2016 to 2018, 2020 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.896 bar
- Unit
- bar
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Spare tire temperature CHR_TT_5Confirmed
- Service 22
DID 1004 - Module
750 → 758 - Every
15 s - Testing for 2016 to 2023, 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -30 to 100 °C
- Unit
- °C
Confirmed for 2025. In testing for 2026. Supported for 2024. Not supported for 2019, 2022 to 2023.
Spare tire temperature CHR_TT_SPARE
- Service 21
PID 16 - Module
750 → 758 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2018, 2020 to 2022, 2026. Supported for 2019. Not supported for 2023 to 2025.
Tire 1 position CHR_TID_1Confirmed
- Service 22
DID 2021 - Module
750 → 758 - Every
86400 s - Testing for 2016 to 2023, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
0x01 = 1 → FL
| Raw value | State | Meaning |
|---|---|---|
1 | FL | Front left |
2 | FR | Front right |
3 | RL | Rear left |
4 | RR | Rear right |
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2019, 2022 to 2023.
Tire 2 position CHR_TID_2Confirmed
- Service 22
DID 2021 - Module
750 → 758 - Every
86400 s - Testing for 2016 to 2023, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
0x03 = 3 → RL
| Raw value | State | Meaning |
|---|---|---|
1 | FL | Front left |
2 | FR | Front right |
3 | RL | Rear left |
4 | RR | Rear right |
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2019, 2022 to 2023.
Tire 3 position CHR_TID_3Confirmed
- Service 22
DID 2021 - Module
750 → 758 - Every
86400 s - Testing for 2016 to 2023, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 16 to 23 of the reply, 8 bits.
- Unit
- Named states
0x02 = 2 → FR
| Raw value | State | Meaning |
|---|---|---|
1 | FL | Front left |
2 | FR | Front right |
3 | RL | Rear left |
4 | RR | Rear right |
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2019, 2022 to 2023.
Tire 4 position CHR_TID_4Confirmed
- Service 22
DID 2021 - Module
750 → 758 - Every
86400 s - Testing for 2016 to 2023, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 24 to 31 of the reply, 8 bits.
- Unit
- Named states
0x04 = 4 → RR
| Raw value | State | Meaning |
|---|---|---|
1 | FL | Front left |
2 | FR | Front right |
3 | RL | Rear left |
4 | RR | Rear right |
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2019, 2022 to 2023.
Tire pressure 1, set 2 CHR_TIRE_P_1_SET_2
- Service 21
PID 15 - Module
750 → 758 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -0.5 to 3.89 bar
- Unit
- bar
In testing for 2016 to 2018, 2020 to 2026. Not supported for 2019.
Tire pressure 2, set 2 CHR_TIRE_P_2_SET_2
- Service 21
PID 15 - Module
750 → 758 - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -0.5 to 3.89 bar
- Unit
- bar
In testing for 2016 to 2018, 2020 to 2026. Not supported for 2019.
Tire pressure 3, set 2 CHR_TIRE_P_3_SET_2
- Service 21
PID 15 - Module
750 → 758 - Every
15 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -0.5 to 3.89 bar
- Unit
- bar
In testing for 2016 to 2018, 2020 to 2026. Not supported for 2019.
Tire pressure 4, set 2 CHR_TIRE_P_4_SET_2
- Service 21
PID 15 - Module
750 → 758 - Every
15 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -0.5 to 3.89 bar
- Unit
- bar
In testing for 2016 to 2018, 2020 to 2026. Not supported for 2019.
Tire pressure 5, set 2 CHR_TIRE_P_5_SET_2
- Service 21
PID 15 - Module
750 → 758 - Every
15 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -0.5 to 3.89 bar
- Unit
- bar
In testing for 2016 to 2018, 2020 to 2026. Not supported for 2019.
Torque converter turbine wheel speed CHR_TQ_CONV_TURBINE_WHL
- Service 21
PID DA - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Traction control, engine status CHR_TRC_TRAC__ENGINE_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Traction control, status CHR_TRC_TRAC__CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.
Wheel cylinder pressure CHR_WHEEL_CYLINDER_PRESSURE
- Service 21
PID 07 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2016 to 2018, 2020 to 2026. Not supported for 2019.
Transmission
Boosting converter temperature, lower CHR_BOOSTING_CONV_T_LO
- Service 22
DID 10A7 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Boosting converter temperature, upper CHR_BOOSTING_CONV_T_HI
- Service 22
DID 10A7 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Current gear CHR_GEAR_V2
- Service 21
PID DA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
DC-DC converter output current CHR_DC_DC_CONV_OUTPUT
- Service 22
DID 111C - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 199 A
- Unit
- A
In testing for 2019 to 2026.
Gear CHR_GEARConfirmed
- Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.
Gear CHR_GEAR_700
- Service 22
DID 1621 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Lock up state CHR_AT_LOCK_UP_STATE
- Service 22
DID 1620 - Module
700 → 708 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Torque converter and TE1 on CHR_TQ_CONV_TE1_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Torque converter lock-up CHR_TQC_LOCKUPConfirmed
Engages a clutch inside the torque converter to create a direct connection between the engine and transmission, reducing slippage and improving efficiency.
- Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.
Transmission fluid post-converter temperature, variant 3 CHR_TRANS_FLUID_POST_T_3
- Service 22
DID 1628 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, pan var.3 CHR_ATF_T_PAN_V3
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1627 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.
Transmission fluid temperature, variant 5 CHR_ATF_T_V_5
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 8 CHR_ATF_T_V_8
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 9 CHR_ATF_T_V_9
- Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 10 CHR_ATF_T_V_10_7E1
- Service 21
PID 82 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 11 CHR_ATF_T_V_11
- Service 21
PID 82 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 12 CHR_ATF_T_V_12
- Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 14 CHR_ATF_T_V_14
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 14 CHR_ATF_T_V_14_7E1
- Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 21 CHR_ATF_T_V_21
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission fluid temperature, variant 21 CHR_ATF_T_V_21_7E1
- Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Transmission oil pressure calibration, complete CHR_TRANS_OIL_PRESS
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2026.
Transmission shift state ratio CHR_TRANS_SHIFT_ST_RAT
- Service 22
DID 1622 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.999
- Unit
- Number
In testing for 2016 to 2026.
Transmission temperature, pan CHR_ATF_PAN_TConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x5280 = 21120 → = 42.5 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.
Transmission temperature, torque converter CHR_ATF_TQC_TConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x8118 = 33048 → = 89.09375 °C
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.
Trips
Odometer CHR_ENG_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID 0103 - Module
700 → 708 - Every
30 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2016 to 2026.
Odometer CHR_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 21
PID 28 - Module
7E0 → 7E8 - Every
5 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x02A6DA = 173786 → 173,786 km
Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2021, 2026. Not supported for 2022 to 2025.
Odometer CHR_ODO_V2_V2Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 0103 - Module
7D2 → 7DA - Every
10 s - Testing for 2020 to 2022, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x000C17 = 3095 → 3,095 km
Confirmed for 2019, 2023 to 2025. In testing for 2020 to 2022, 2026.
Odometer CHR_ODO_V6Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 0103 - Module
747 → 74F - Every
10 s - Testing for 2016 to 2021, 2026
Example reply from a 2025 Toyota C-HR+.
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x000C16 = 3094 → 3,094 km
Confirmed for 2022 to 2025. In testing for 2020 to 2021, 2026. Not supported for 2019.
Previous trip distance CHR_PREV_TRIP_DSTConfirmed
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 2016 to 2018, 2020 to 2026
Example reply from a 2019 Toyota C-HR+.
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 km
- Unit
- km
0x0041 = 65 → = 0.65 km