Parameters
The Toyota Aqua has 638 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
+BM voltage AQUA_BM_V
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2011 to 2026.
Accumulated time of battery low AQUA_ACCUMULATED_TIME_BAT
- Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2011 to 2026.
Accumulated time of battery too high AQUA_ACCUMULATED_TIME_BAT_TOO
- Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2011 to 2026.
Auxiliary battery temperature AQUA_AUXILIARY_BAT_T
- Service 21
PID 41 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -40 to 215
- Unit
- Number
In testing for 2011 to 2026.
Auxiliary battery voltage AQUA_AUX_V
Pelican can show this parameter as the starter battery voltage.
- Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -25.6 to 25.4 V
- Unit
- V
In testing for 2011 to 2026.
Auxiliary battery voltage AQUA_AUXILIARY_BAT_V
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- -40 to 39.9 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 1 voltage AQUA_BAT_BLOCK_V_V01
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 1 voltage AQUA_BATTERY_BLOCK_VOL_V01
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 2 voltage AQUA_BAT_BLOCK_V_V02
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 2 voltage AQUA_BATTERY_BLOCK_VOL_V02
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 3 voltage AQUA_BAT_BLOCK_V_V03
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 3 voltage AQUA_BATTERY_BLOCK_VOL_V03
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 4 voltage AQUA_BAT_BLOCK_V_V04
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 4 voltage AQUA_BATTERY_BLOCK_VOL_V04
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 5 voltage AQUA_BAT_BLOCK_V_V05
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 5 voltage AQUA_BATTERY_BLOCK_VOL_V05
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 6 voltage AQUA_BAT_BLOCK_V_V06
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 6 voltage AQUA_BATTERY_BLOCK_VOL_V06
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 7 voltage AQUA_BAT_BLOCK_V_V07
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 7 voltage AQUA_BATTERY_BLOCK_VOL_V07
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 8 voltage AQUA_BAT_BLOCK_V_V08
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 8 voltage AQUA_BATTERY_BLOCK_VOL_V08
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 9 voltage AQUA_BAT_BLOCK_V_V09
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 9 voltage AQUA_BATTERY_BLOCK_VOL_V09
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 10 voltage AQUA_BATTERY_BLOCK_VOL_V10
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 10 voltage, raw count AQUA_BAT_BLOCK_V_V10_RAW
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99
- Unit
- Number
In testing for 2011 to 2026.
Battery block 11 voltage AQUA_BAT_BLOCK_V_V11
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 11 voltage AQUA_BATTERY_BLOCK_VOL_V11
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 12 voltage AQUA_BAT_BLOCK_V_V12
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 12 voltage AQUA_BATTERY_BLOCK_VOL_V12
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 13 voltage AQUA_BAT_BLOCK_V_V13
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 13 voltage AQUA_BATTERY_BLOCK_VOL_V13
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 14 voltage AQUA_BAT_BLOCK_V_V14
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 14 voltage AQUA_BATTERY_BLOCK_VOL_V14
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 15 voltage AQUA_BATTERY_BLOCK_VOL_V15
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 16 voltage AQUA_BAT_BLOCK_V_V16
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 V
- Unit
- V
In testing for 2011 to 2026.
Battery block 17 voltage AQUA_BAT_BLOCK_V_V17
- Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block number with, maximum voltage AQUA_BAT_BLOCK_NUMBER_MAX_V
- Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2011 to 2026.
Battery block number with, minimum voltage AQUA_BAT_BLOCK_NUMBER_MIN_V
- Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2011 to 2026.
Battery block, maximum voltage AQUA_BAT_BLOCK_MAX_V
- Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery block, minimum voltage AQUA_BAT_BLOCK_MIN_V
- Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Battery current AQUA_BAT_CURRENT
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2011 to 2026.
Battery temperature AQUA_BAT_T
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6513.5 °C
- Unit
- °C
In testing for 2011 to 2026.
Battery voltage AQUA_BAT_V
- Service 21
PID 13 - Module
7C0 → 7C8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2011 to 2026.
Boost converter carrier frequency AQUA_CONV_CARRIER
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 71 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Boost converter gate AQUA_CONV_GATE
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 66 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Boost converter input voltage AQUA_VL
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 V
- Unit
- V
In testing for 2011 to 2026.
Boost converter output voltage AQUA_VH
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 V
- Unit
- V
In testing for 2011 to 2026.
Boost converter pressure ratio AQUA_BOOST_RATIO
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.96 %
- Unit
- %
In testing for 2011 to 2026.
Boost converter temperature AQUA_CONV_T
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2011 to 2026.
Charge contactor current AQUA_SCC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2011 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2012. Supported for 2014.
Delta SOC AQUA_DELTA_SOC
- Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2011 to 2026.
Engine control module control mode, driving control mode=1,current sensor offset mode=2,external charge control mode=3,power supply end mode=4 AQUA_ENG_CTRL_MODULE_CTRL_1_2_3_4
- Service 21
PID 9B - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
High voltage battery charge control, kw AQUA_HVBAT_CHG_CTRL_KW
- Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5
- Unit
- Number
In testing for 2011 to 2026.
High voltage battery discharge control, kw AQUA_HVBAT_DCHG_CTRL_KW
- Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5
- Unit
- Number
In testing for 2011 to 2026.
High voltage battery intake air temperature AQUA_HVBAT_IAT
- Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2011 to 2026.
HV battery block 1 internal resistance AQUA_HVBAT_BLOCK_1_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 1 voltage AQUA_HVBAT_BLOCK_1_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 2 internal resistance AQUA_HVBAT_BLOCK_2_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 2 voltage AQUA_HVBAT_BLOCK_2_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 3 internal resistance AQUA_HVBAT_BLOCK_3_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 3 voltage AQUA_HVBAT_BLOCK_3_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 4 internal resistance AQUA_HVBAT_BLOCK_4_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 4 voltage AQUA_HVBAT_BLOCK_4_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 5 internal resistance AQUA_HVBAT_BLOCK_5_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 5 voltage AQUA_HVBAT_BLOCK_5_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 6 internal resistance AQUA_HVBAT_BLOCK_6_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 6 voltage AQUA_HVBAT_BLOCK_6_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 7 internal resistance AQUA_HVBAT_BLOCK_7_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 7 voltage AQUA_HVBAT_BLOCK_7_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 8 internal resistance AQUA_HVBAT_BLOCK_8_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 8 voltage AQUA_HVBAT_BLOCK_8_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 9 internal resistance AQUA_HVBAT_BLOCK_9_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 9 voltage AQUA_HVBAT_BLOCK_9_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 10 internal resistance AQUA_HVBAT_BLOCK_10_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 10 voltage AQUA_HVBAT_BLOCK_10_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 11 internal resistance AQUA_HVBAT_BLOCK_11_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 11 voltage AQUA_HVBAT_BLOCK_11_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 12 internal resistance AQUA_HVBAT_BLOCK_12_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 12 voltage AQUA_HVBAT_BLOCK_12_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 13 internal resistance AQUA_HVBAT_BLOCK_13_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 13 voltage AQUA_HVBAT_BLOCK_13_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block 14 internal resistance AQUA_HVBAT_BLOCK_14_R
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2011 to 2026.
HV battery block 14 voltage AQUA_HVBAT_BLOCK_14_V
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block count AQUA_HVBAT_BLOCKS
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
HV battery block voltage, highest AQUA_HVBAT_BLOCK_V_MAX
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block voltage, lowest AQUA_HVBAT_BLOCK_V_MIN
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2011 to 2026.
HV battery block with the highest voltage AQUA_HVBAT_BLOCK_V_MAX_NO
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
HV battery block with the lowest voltage AQUA_HVBAT_BLOCK_V_MIN_NO
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
HV battery charge AQUA_HVBAT_SOC
Pelican can show this parameter as the state of charge.
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 2011 to 2026.
HV battery charge power limit AQUA_HVBAT_CHG_LIM
- Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -64 to 191 kW
- Unit
- kW
In testing for 2011 to 2026.
HV battery charge spread AQUA_HVBAT_DELTA_SOC
- Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 2.55 %
- Unit
- %
In testing for 2011 to 2026.
HV battery charge, hybrid control AQUA_HV_SOC
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.96 %
- Unit
- %
In testing for 2011 to 2026.
HV battery current AQUA_HVBAT_I
Pelican can show this parameter as the traction battery current.
- Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2011 to 2026.
HV battery DC inhibit time AQUA_HVBAT_DC_INHIBIT_TIME
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2011 to 2026.
HV battery discharge power limit AQUA_HVBAT_DISCHG_LIM
- Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -64 to 191 kW
- Unit
- kW
In testing for 2011 to 2026.
HV battery discharge power limit AQUA_WOUT
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
- Range
- 0 to 81600 W
- Unit
- W
In testing for 2011 to 2026.
HV battery fan motor voltage AQUA_HVBAT_FAN_V
- Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -25.6 to 25.4 V
- Unit
- V
In testing for 2011 to 2026.
HV battery fan speed AQUA_HVBAT_FAN
- Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
HV battery high charge time AQUA_HVBAT_HIGH_TIME
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2011 to 2026.
HV battery hot temperature time AQUA_HVBAT_HOT_TIME
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2011 to 2026.
HV battery intake air temperature AQUA_HVBAT_INTAKE_T
- Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2011 to 2026.
HV battery low charge time AQUA_HVBAT_LOW_TIME
- Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2011 to 2026.
HV battery temperature 1 AQUA_HVBAT_T_1
- Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2011 to 2026.
HV battery temperature 2 AQUA_HVBAT_T_2
- Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2011 to 2026.
HV battery temperature 3 AQUA_HVBAT_T_3
- Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2011 to 2026.
Input over-voltage to converter AQUA_OVERVOLTAGE_INPUT
- Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 33 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Input over-voltage to inverter AQUA_OVERVOLTAGE_INPUT_INVERTER
- Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 34 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Main battery charging requested AQUA_CHARGE_REQ
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Main connector solenoid current AQUA_SMC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2011 to 2026.
Main relay a, solenoid current AQUA_SLA_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2011 to 2026.
Main relay r solenoid current AQUA_SLR_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2011 to 2026.
Number of battery blocks AQUA_NUM_BAT_BLOCKS
- Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Output speed sensor voltage AQUA_NOUT_SENS_V
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2011 to 2026.
Power resource current AQUA_IB
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
- Range
- -256 to 254 A
- Unit
- A
In testing for 2011 to 2026.
Power resource voltage AQUA_VB
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 V
- Unit
- V
In testing for 2011 to 2026.
Regenerative braking cooperation AQUA_REGEN_COOPERATION
- Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Regenerative operation AQUA_FR_REGEN_OPERATION
- Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2011 to 2026.
Regenerative request AQUA_FR_REGEN_REQUEST
- Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2011 to 2026.
Relay control solenoid current AQUA_SRC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2011 to 2026.
Service contactor solenoid current AQUA_SSC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2011 to 2026.
Short circuit wave highest value AQUA_SHORT_WAVE_V
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2011 to 2026.
SOC at ignition on AQUA_SOC_AFTER_IG_ON
- Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2011 to 2026.
SOC max AQUA_SOC_MAX
- Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2011 to 2026.
SOC min AQUA_SOC_MIN
- Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2011 to 2026.
State of charge, all bat AQUA_ST_CHG_ALL_BAT
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2011 to 2026.
System main relay 1 AQUA_SMR1
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 63 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
System main relay 2 AQUA_SMR2
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 62 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
System main relay 3 AQUA_SMR3
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 61 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Turbine speed sensor voltage AQUA_NT_SENS_V
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2011 to 2026.
Vh-voltage after boosting AQUA_VH_V_AFTER_BOOSTING_7E2
- Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 V
- Unit
- V
In testing for 2011 to 2026.
Vl-voltage before boosting AQUA_VL_V_BEFORE_BOOSTING_7E2
- Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 V
- Unit
- V
In testing for 2011 to 2026.
Brakes
Master cylinder sensor temperature AQUA_MASTER_CYL_TEMP
- Service 22
DID 1006 - Module
7B0 → 7B8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -20 to 100 °C
- Unit
- °C
In testing for 2011, 2013 to 2026. Not supported for 2012.
Climate
Adjusted ambient temperature AQUA_ADJUSTED_AMBIENT_T
- Service 21
PID 3D - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -30.8 to 50.8 °C
- Unit
- °C
In testing for 2011 to 2026.
Air conditioning inverter gate AQUA_AC_GATE
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 67 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Air conditioning power consumption AQUA_AC_PWR
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 kW
- Unit
- kW
In testing for 2011 to 2026.
Air conditioning requested AQUA_AC_REQ
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Air inlet damper actual pulse AQUA_AIR_INLET_DAMPER_ACTUAL_PULSE
- Service 21
PID 44 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Air inlet damper target pulse AQUA_AIR_INLET_DAMPER_TARGET_PULSE
- Service 21
PID 44 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Air outlet servo actual pulse, driver AQUA_AIR_OUTLET_SERVO_ACTU_PULSE_D
- Service 21
PID 43 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Air outlet servo pulse, driver AQUA_AIR_OUTLET_SERVO_PULSE_D
- Service 21
PID 43 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Ambient air temperature AQUA_AAT_7C4
- Service 21
PID 22 - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -23.3 to 65.95 °C
- Unit
- °C
In testing for 2011 to 2026.
Blower motor speed level AQUA_BLOWER_MOTOR_SPEED_LEVEL
- Service 21
PID 3C - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Cabin temperature AQUA_CABIN_T
- Service 21
PID 21 - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -6.5 to 57.25 °C
- Unit
- °C
In testing for 2011 to 2026.
Climate control engine run requested AQUA_HVAC_REQ
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Communication with air conditioner AQUA_COMM_WITH_AIR_CONDITIONER
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Communication with HV AQUA_COMMUNICATION_WITH_HV
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Communication with valvematic AQUA_COMM_WITH_VALVEMATIC_COMM
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Evaporator fin thermistor AQUA_EVAP_FIN_THERMISTOR
- Service 21
PID 4B - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -29.7 to 59.55 °C
- Unit
- °C
In testing for 2011 to 2026.
Evaporator target temperature AQUA_EVAP_TARGET_T
- Service 21
PID 4C - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Number
In testing for 2011 to 2026.
Set temperature, driver side AQUA_T_DRIVER
- Service 21
PID 29 - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2011 to 2026.
Solar sensor, driver side AQUA_SOLAR_DRIVER
- Service 21
PID 24 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Control
A/C compressor AQUA_A_C_COMPRESSOR
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 64 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Accelerator pedal position AQUA_APP
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.96 %
- Unit
- %
In testing for 2011 to 2026.
Anti-lock brake warning light AQUA_ABS_WARN
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Brake warning light AQUA_BRAKE_WARN
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Buzzer AQUA_BUZZER
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Communication with brake AQUA_COMMUNICATION_WITH_BRAKE
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cruise control active AQUA_CRUISE
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cruise control cancel switch AQUA_CANCEL
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cruise control indicator AQUA_CRUISE_IND
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cruise control live brake cancel AQUA_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCH
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Cruise control main switch AQUA_CRUISE_MAIN
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cruise control ready AQUA_CRUISE_READY
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cruise control resume switch AQUA_RES_ACC
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cruise control set speed AQUA_CRUISE_SPD
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2011 to 2026.
Cruise control set switch AQUA_SET_COAST
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cruise control throttle opening AQUA_CRUISE_THROTTLE
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2011 to 2026.
Electrical load signal 1 AQUA_ELECTRICAL_LOAD_SIGNAL_1
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Electrical load signal 2 AQUA_ELECTRICAL_LOAD_SIGNAL_2
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Electronically controlled brake warning light AQUA_ECB_WARN
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Ignition trigger count AQUA_IGNITION_TRIG_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2011 to 2026.
Key remind sound AQUA_KEY_REMIND_SOUND
- Service 21
PID A1 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Main idle AQUA_MAIN_IDLE_SW
- Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Master cylinder torque AQUA_MC_TQ
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- -512 to 508 N·m
- Unit
- N·m
In testing for 2011 to 2026.
Neutral position AQUA_NEUTRAL_POSITION_SW_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 53 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Parking brake AQUA_PARKING_BRAKEConfirmed
- Service 21
PID 62 - Module
7D0 - Every
1 s - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Parking brake AQUA_PARKING_BRAKE_SW
- Service 21
PID 1F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Pattern switch AQUA_PATTERN_SWITCH_PWR_M
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 42 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Power steering AQUA_POWER_STEERING_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Regenerative brake torque AQUA_REGEN_TQ
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 N·m
- Unit
- N·m
In testing for 2011 to 2026.
Regenerative brake torque requested AQUA_REGEN_TQ_REQ
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 N·m
- Unit
- N·m
In testing for 2011 to 2026.
Reservoir warning AQUA_RESERVOIR_WARNING_SW
- Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Shift SW status, drive AQUA_SHIFT_SW_STATUS_D_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Shift SW status, neutral AQUA_SHIFT_SW_STATUS_N_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Shift SW status, parking AQUA_SHIFT_SW_STATUS_P_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Shift SW status, reverse AQUA_SHIFT_SW_STATUS_R_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Slip indicator light AQUA_SLIP_WARN
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Sports mode selection AQUA_SPORTS_MODE_SELECTION_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 32 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Sports shift down AQUA_SPORTS_SHIFT_DOWN_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 34 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Sports shift up AQUA_SPORTS_SHIFT_UP_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 33 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Starter control AQUA_STARTER_CONTROL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Starter signal AQUA_STARTER_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Steering wheel angle AQUA_STEER_ANGLEConfirmed
Positive = counter-clockwise, negative = clockwise.
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
0x80A5 = 32933 → = 16.5 °
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Stop light switch 1, main processor AQUA_STOP_SW1_MAIN
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Stop light switch 1, sub processor AQUA_STOP_SW1_SUB
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Stop light switch 2, sub processor AQUA_STOP_SW2_SUB
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
TC AQUA_TC_TERMINAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 61 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Traction control, brake status AQUA_TRC_TRAC__BRAKE_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cruise control
Cruise control speed AQUA_CC_S
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2011, 2013 to 2026. Not supported for 2012.
Details
Inspection mode AQUA_INSPECTION_MODE
- Service 21
PID A6 - Module
7B0 → 7B8 - Every
60 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Doors
Smart key AQUA_SMART_KEY
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 69 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
DTCs
2nd air monitor available? AQUA_2ND_AIR_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
2nd air monitor incomplete? AQUA_2ND_AIR_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
A/C monitor available? AQUA_A_C_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
A/C monitor incomplete? AQUA_A_C_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Catalyst monitor available? AQUA_CATALYST_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Catalyst monitor incomplete? AQUA_CATALYST_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Complete parts monitor available? AQUA_COMPLETE_PARTS_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2012. Supported for 2014.
EGR/VVT monitor available? AQUA_EGR_VVT_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
EGR/VVT monitor incomplete? AQUA_EGR_VVT_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
EVAP monitor available? AQUA_EVAP_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
EVAP monitor_icmpl AQUA_EVAP_MONITOR_ICMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Fuel system monitor available? AQUA_FUEL_SYSTEM_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Heated catalyst monitor available? AQUA_HEATED_CATALYST_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Heated catalyst monitor incomplete? AQUA_HEATED_CATALYST_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
MIL AQUA_MIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
MIL ON run distance AQUA_MILON_RUN_DISTANCE
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2011 to 2026.
Misfire monitor available? AQUA_MISFIRE_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Number of emission DTC AQUA_NUMBER_OF_EMISSION_DTC
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 2011 to 2026.
O2S heater monitor available? AQUA_O2S_A_FS_HEATER_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
O2S heater monitor incomplete? AQUA_O2S_A_FS_HEATER_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
O2S monitor available? AQUA_O2S_A_FS_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
O2S monitor incomplete? AQUA_O2S_A_FS_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Running time from MIL ON AQUA_RUNNING_TIME_FROM_MIL_ON
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 2011 to 2026.
Electrical
B+ battery voltage AQUA_BATTERY_VOLTAGE
- Service 22
DID 1021 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20 V
- Unit
- V
In testing for 2011, 2013 to 2026. Not supported for 2012.
Engine
+B AQUA_B
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2011 to 2026.
A/C gate status AQUA_AIRCON_GATE_STAT
- Service 21
PID 75 - Module
7E2 → 7EA - Every
5 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
A/F heater duty bank 1 sensor 1 AQUA_F_HEATER_DUTY_B1S1
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2011 to 2026.
A/F test results 1, incomplete AQUA_F_TEST_RESULTS_1
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Accessory relay on AQUA_ACC_RELAY_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 46 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Accumulated time of DC inhibit AQUA_ACCUMULATED_TIME_DC
- Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2011 to 2026.
Accumulated time of hot temperature AQUA_ACCUMULATED_TIME_HOT_T
- Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2011 to 2026.
Accumulator open AQUA_ACCUMULATOR_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Acoustic control induction system vacuum switching valve on AQUA_ACIS_VSV_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Actual engine torque AQUA_ACT_ENG_TQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2011 to 2026.
Actuator power supply on AQUA_ACTUATOR_POWER_SUP_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 146 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Air conditioning compressor AQUA_AC_COMP
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Air conditioning consumption power, w AQUA_AC_CONS_POWER_W
- Service 21
PID 7D - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750
- Unit
- Number
In testing for 2011 to 2026.
Air mix servo target pulse, driver AQUA_AIR_MIX_SERVO_TARG_D
- Service 21
PID 41 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Air mix servo, actual pulse, d AQUA_AIR_MIX_SERVO_ACT_D
- Service 21
PID 41 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Air-fuel equivalence ratio, bank 1 sensor 1 AQUA_AF_LAMBDA_B1S1
Pelican can show this parameter as the O2 lambda.
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2011 to 2026.
Air-fuel sensor current, bank 1 sensor 1 AQUA_AFS_I_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.99 mA
- Unit
- mA
In testing for 2011 to 2026.
Air-fuel sensor voltage, bank 1 sensor 1 AQUA_AFS_V_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.99 V
- Unit
- V
In testing for 2011 to 2026.
Alt voltage - active test AQUA_ALT_VOL_ACTIVE_TEST
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2011 to 2026.
Alt voltage - non active test AQUA_ALT_VOL_NON_ACTIVE
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2011 to 2026.
Alternator output duty AQUA_ALTERNATOR_OUTPUT
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2011 to 2026.
Ambient temperature AQUA_AAT_7E2
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Atmosphere pressure_7e2 AQUA_ATMOSPHERE_P_7E2
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2011 to 2026.
Barometric pressure AQUA_BARO
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2011 to 2026.
Battery pack current AQUA_BATT_PACK_CURRENT
- Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -327680 to 327670 mA
- Unit
- mA
In testing for 2011 to 2026.
Battery pack, current value AQUA_BATT_PACK_CUR_VAL
- Service 21
PID CE - Module
7E2 → 7EA - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2011 to 2026.
Battery temperature TB1 AQUA_T_BATT_TB1
- Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2011 to 2026.
Battery temperature TB2 AQUA_T_BATT_TB2
- Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2011 to 2026.
Battery temperature TB3 AQUA_T_BATT_TB3
- Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2011 to 2026.
Boost ratio AQUA_BOOST_RAT
- Service 21
PID 7D - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2011 to 2026.
Calculated load AQUA_LOAD
Pelican can show this parameter as the engine load.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2011 to 2026.
Calculated load_7e2 AQUA_CALC_LOAD_7E2
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2011 to 2026.
Cancel switch AQUA_CANCEL_SWITCH
- Service 21
PID 21 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 37 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Catalyst temperature, bank 1 sensor 1 AQUA_CAT_T_B1S1
- Service 21
PID 05 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2011 to 2026.
Catalyst temperature, bank 1 sensor 2 AQUA_CAT_T_B1S2
- Service 21
PID 05 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2011 to 2026.
Catalyst temperature, bank 1 sensor 2, variant 2 AQUA_CAT_T_B1S2_V2
- Service 21
PID 3E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2011 to 2026.
Check mode AQUA_CHECK_MODE
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Check mode on AQUA_CHECK_MODE_ON
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Closed throttle position switch on AQUA_CLOSED_THROTTLE_POS_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 125 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Codes, include history AQUA_CODES_INCLUDE
- Service 21
PID E1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Continuously variable transmission learning complete AQUA_CVT_LEARNED
- Service 21
PID DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2011 to 2026.
Continuously variable transmission oil pressure AQUA_CVT_OIL_P
- Service 21
PID BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 10200 kPa
- Unit
- kPa
In testing for 2011 to 2026.
Cooling fan 0 AQUA_COOLING_FAN_0
- Service 21
PID 8E - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2011 to 2026.
Cooling fan mode 1 AQUA_COOLING_FAN_MODE_1
- Service 21
PID 9B - Module
7E2 → 7EA - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Cooling fan relay status AQUA_COOLING_FAN_RELAY
- Service 21
PID 8E - Module
7E2 → 7EA - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Crank position AQUA_CRANK_POS
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 180.03 °
- Unit
- °
In testing for 2011 to 2026.
Cruise control AQUA_CRUISE_CTRL
- Service 21
PID 21 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cruise control on AQUA_CRUISE_CTRL_ON
- Service 21
PID D3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cruise control remembered vehicle speed AQUA_CCS_MEM_VEH_SPD
- Service 21
PID 21 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2011 to 2026.
Cruise control vehicle speed AQUA_CCS_VEH_SPD
- Service 21
PID 21 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2011 to 2026.
Cruise operation status AQUA_CRUISE_OPERATION
- Service 21
PID 21 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cruise resume and accelerate switch AQUA_RES_ACC_SWITCH
- Service 21
PID 21 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 35 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Cylinder number AQUA_CYLINDER_NUMBER
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
DC/DC converter, target pulse duty AQUA_DCDC_CNV_TGT_DUTY
- Service 21
PID 79 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2011 to 2026.
Destination AQUA_DESTINATION
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Destination code AQUA_DESTINATION_AMERICA_65
- Service 21
PID C1 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Dist battery cable disconnect AQUA_DIST_BATT_CABLE
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2011 to 2026.
Drive condition AQUA_DRIVE_COND
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Driving pattern 1 AQUA_DRIVE_PATTERN_1
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Driving pattern 2 AQUA_DRIVE_PATTERN_2
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Driving pattern 3 AQUA_DRIVE_PATTERN_3
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
DTC clear min, raw count AQUA_DTC_CLEAR_MIN_RAW
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2011 to 2026.
DTC clear warm up AQUA_DTC_CLEAR_WARM_UP
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Electric fan motor on AQUA_ELEC_FAN_MOTOR_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 34 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Engine code, P410, raw count AQUA_ENG_CODE_P410_RAW
- Service 21
PID C1 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 695,928,576 to 695,928,583 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Engine control module code, raw count AQUA_ENG_CTRL_MODULE_CODE
- Service 21
PID C2 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 154,160 to 154,167 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Engine coolant temperature AQUA_ECT
Pelican can show this parameter as the engine coolant temperature.
- Service 21
PID 26 - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 1.3 to 90.55 °C
- Unit
- °C
In testing for 2011 to 2026.
Engine coolant temperature AQUA_ECT_7C0
Pelican can show this parameter as the engine coolant temperature.
- Service 21
PID 23 - Module
7C0 → 7C8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2011 to 2026.
Engine coolant temperature AQUA_ECT_7E0
Pelican can show this parameter as the engine coolant temperature.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2012. Supported for 2014.
Engine coolant temperature_7e2 AQUA_ECT_7E2
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Engine idle requested AQUA_IDLE_REQ
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Engine independent AQUA_ENG_INDEPENDENT
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 91 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Engine independent control AQUA_ENG_INDEPENDENT_CTRL
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 88 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Engine oil temperature AQUA_EOTConfirmed
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x30 = 48 → = 8 °C
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Engine rev, sensor AQUA_ENG_REV_SENS
- Service 21
PID 41 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2012. Supported for 2014.
Engine run time AQUA_ENG_RUN_TIME
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2011 to 2026.
Engine run time, up to 255 sec. only AQUA_ENG_RUN_TIME_UP_255
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 s
- Unit
- s
In testing for 2011 to 2026.
Engine speed AQUA_ENG_RPM
Pelican can show this parameter as the engine speed.
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Engine stall control FB flow AQUA_ENG_STALL_CTRL_FB
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 39.99
- Unit
- Number
In testing for 2011 to 2026.
Engine stop inhibit requested AQUA_STOP_INHIBIT_REQ
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Engine stop requested AQUA_STOP_REQ
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Engine warm-up requested AQUA_WARMUP_REQ
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Evaporative purge duty AQUA_EVAP_PURGE_DUTY_7E0
- Service 21
PID 2E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2011 to 2026.
Evaporative purge flow AQUA_EVAP_PURGE_FLOW
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.99 %
- Unit
- %
In testing for 2011 to 2026.
Evaporative purge vacuum switching valve on AQUA_EVAP_PURGE_VSV_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Exhaust gas recirculation step position AQUA_EGR_STEP_POSITION
- Service 21
PID 47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Exhaust gas recirculation temperature AQUA_EGR_T
- Service 21
PID ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 159 °C
- Unit
- °C
In testing for 2011 to 2026.
Exhaust gas recirculation valve step AQUA_EGR_STEP
- Service 21
PID E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Fuel cut for engine stop request AQUA_F_C_ENG_STOP_REQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 92 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Fuel cut TAU on AQUA_FC_TAU_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 127 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
G sensor calibration, complete AQUA_G_SENS_CALIBRATION
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
G sensor learning value AQUA_G_SENS_LEARNING
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2011 to 2026.
Glass humidity AQUA_GLASS_HUMIDITY
- Service 21
PID B1 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2011 to 2026.
Glass temperature AQUA_GLASS_T
- Service 21
PID AF - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -557 to 621 °F
- Unit
- °F
In testing for 2011 to 2026.
Hydraulic valve, communication open AQUA_HV_COMM_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
ICE, actual torque AQUA_ICE_ACT_TQ
- Service 21
PID CD - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 N·m
- Unit
- N·m
In testing for 2011 to 2026.
Idle control AQUA_IDLE_CTRL
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Idle spark advance control 1 AQUA_IDLE_SPARK_ADVN_CTRL_1
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2011 to 2026.
Idle spark advance control 2 AQUA_IDLE_SPARK_ADVN_CTRL_2
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2011 to 2026.
Idle spark advance control 3 AQUA_IDLE_SPARK_ADVN_CTRL_3
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2011 to 2026.
Idle spark advance control 4 AQUA_IDLE_SPARK_ADVN_CTRL_4
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2011 to 2026.
Idle speed control learning AQUA_IDLE_SPD_CTRL
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 93 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Idle speed control learning value, l/s AQUA_IDLE_SPD_CTRL_L_S
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99
- Unit
- Number
In testing for 2011 to 2026.
IG OFF elapsed time AQUA_IG_OFF_ELAPSED_TIME
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 min
- Unit
- min
In testing for 2011 to 2026.
Ignition advance AQUA_SPARKADV_21
- Service 21
PID 0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2011 to 2026.
Ignition timing advance AQUA_IGN_ADVANCE
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2011 to 2026.
Immobilizer communication on AQUA_IMMOBILIZER_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 120 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Initial engine coolant temperature AQUA_INITIAL_ECT
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119.3
- Unit
- Number
In testing for 2011 to 2026.
Initial intake air temperature AQUA_INITIAL_IAT
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2011 to 2026.
Injection duration for cylinder 1 AQUA_INJ_DUR_CYL_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2011 to 2026.
Injection volume per 10 injections, cylinder 1 AQUA_INJ_VOL_CYL_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.002 L
- Unit
- L
In testing for 2011 to 2026.
Injector pulse width AQUA_INJ_PW
- Service 21
PID E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.6 ms
- Unit
- ms
In testing for 2011 to 2026.
Injector pulse width AQUA_INJ_WIDTH
- Service 21
PID F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.64 ms
- Unit
- ms
In testing for 2011 to 2026.
Input shaft speed AQUA_SPD_NIN
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Intake air temperature AQUA_IAT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Intake air temperature AQUA_IAT_21
- Service 21
PID 0F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Intake air temperature_7e2 AQUA_IAT_7E2
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Internal resistance 1 AQUA_INTERNAL_RESISTANCE_R01
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 2 AQUA_INTERNAL_RESISTANCE_R02
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 3 AQUA_INTERNAL_RESISTANCE_R03
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 4 AQUA_INTERNAL_RESISTANCE_R04
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 5 AQUA_INTERNAL_RESISTANCE_R05
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 6 AQUA_INTERNAL_RESISTANCE_R06
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 7 AQUA_INTERNAL_RESISTANCE_R07
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 8 AQUA_INTERNAL_RESISTANCE_R08
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 9 AQUA_INTERNAL_RESISTANCE_R09
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 10 AQUA_INTERNAL_RESISTANCE_R10
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 11 AQUA_INTERNAL_RESISTANCE_R11
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 12 AQUA_INTERNAL_RESISTANCE_R12
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 13 AQUA_INTERNAL_RESISTANCE_R13
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 14 AQUA_INTERNAL_RESISTANCE_R14
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance 15 AQUA_INTERNAL_RESISTANCE_R15
- Service 21
PID D0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 MΩ
- Unit
- MΩ
In testing for 2011 to 2026.
Internal resistance R01 AQUA_INTERNAL_RES_R01
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R02 AQUA_INTERNAL_RES_R02
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R03 AQUA_INTERNAL_RES_R03
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R04 AQUA_INTERNAL_RES_R04
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R05 AQUA_INTERNAL_RES_R05
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R06 AQUA_INTERNAL_RES_R06
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R07 AQUA_INTERNAL_RES_R07
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R08 AQUA_INTERNAL_RES_R08
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R09 AQUA_INTERNAL_RES_R09
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R10 AQUA_INTERNAL_RES_R10
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R11 AQUA_INTERNAL_RES_R11
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R12 AQUA_INTERNAL_RES_R12
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R13 AQUA_INTERNAL_RES_R13
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R14 AQUA_INTERNAL_RES_R14
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R15 AQUA_INTERNAL_RES_R15
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R16 AQUA_INTERNAL_RES_R16
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Internal resistance R17 AQUA_INTERNAL_RES_R17
- Service 21
PID 95 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.255 Ω
- Unit
- Ω
In testing for 2011 to 2026.
Inverter coolant temperature AQUA_INVERTER_ECT
- Service 21
PID 75 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215
- Unit
- Number
In testing for 2011 to 2026.
Inverter MG1 temperature AQUA_INVERTER_MG1_T
- Service 21
PID 70 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Inverter MG1 temperature at ignition on AQUA_INVERTER_MG1_T_AFTER_ON
- Service 21
PID 70 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Inverter MG1 temperature max AQUA_INVERTER_MG1_T_MAX
- Service 21
PID 70 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Inverter MG2 temperature AQUA_INVERTER_MG2_T
- Service 21
PID 71 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Inverter MG2 temperature at ignition on AQUA_INVERTER_MG2_T_AFTER_ON
- Service 21
PID 71 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Inverter MG2 temperature max AQUA_INVERTER_MG2_T_MAX
- Service 21
PID 71 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Inverter water pump revolution AQUA_INVERTER_WATER_PMP_REVOLUTION
- Service 21
PID 75 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Judge time engine ignition AQUA_JUDGE_TIME_ENG_IGN
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2011 to 2026.
Judge time engine output AQUA_JUDGE_TIME_ENG
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2011 to 2026.
Knock adjust AQUA_KNOCK_ADJUST
- Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -64 to 1984 °
- Unit
- °
In testing for 2011 to 2026.
Knock adjust AQUA_KNOCK_ADJUST_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1024 °
- Unit
- °
In testing for 2011 to 2026.
Knock correct learn value AQUA_KNOCK_CORRECT_LEARN
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1023 °
- Unit
- °
In testing for 2011 to 2026.
Knock feedback AQUA_KNOCK_FEEDBACK
- Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -64 to 1984 °
- Unit
- °
In testing for 2011 to 2026.
Knock feedback AQUA_KNOCK_FEEDBACK_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1024 °
- Unit
- °
In testing for 2011 to 2026.
Loading condition AQUA_LOADING
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Long term fuel trim, bank 1 AQUA_LONG_FT_B1
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2011 to 2026.
Long term fuel trim, bank 2 AQUA_LONG_FT_B2
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2011 to 2026.
Long-term fuel trim, bank 1 AQUA_LTFT1_21
- Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.15 %
- Unit
- %
In testing for 2011 to 2026.
Manifold air pressure_7e2 AQUA_MANIFOLD_AIR_P_7E2
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2011 to 2026.
Mass air flow AQUA_MAF
Pelican can show this parameter as the mass air flow.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 2011 to 2026.
Mass air flow AQUA_MAF_21
- Service 21
PID 10 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 g/s
- Unit
- g/s
In testing for 2011 to 2026.
Master cylinder open AQUA_MASTER_CYLINDER_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
MG1 carrier frequency AQUA_MG1_CARRIER
- Service 21
PID 7C - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 Hz
- Unit
- Hz
In testing for 2011 to 2026.
MG1 control mode, pwm=0,variable pwm=1,rectangular wave=2 AQUA_MG1_CTRL_MODE_PWM_0_1_2
- Service 21
PID 67 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
MG1 gate status AQUA_MG1_GATE_STAT
- Service 21
PID 70 - Module
7E2 → 7EA - Every
5 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
MG1 inverter fail AQUA_MG1_INVERTER_FAIL
- Service 21
PID 78 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
MG1 inverter shutdown AQUA_MG1_INVERTER
- Service 21
PID 78 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
MG1 revolution AQUA_MG1_REVOLUTION
- Service 21
PID 61 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2011 to 2026.
MG1 temperature AQUA_MG1_T
- Service 21
PID 61 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
MG1 temperature at ignition on AQUA_MG1_T_AFTER_IG_ON
- Service 21
PID 61 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
MG1 temperature max AQUA_MG1_T_MAX
- Service 21
PID 61 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
MG1 torque AQUA_MG1_TQ_7E2
- Service 21
PID 67 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 N·m
- Unit
- N·m
In testing for 2011 to 2026.
MG1 torque execution value AQUA_MG1_TQ_EXECUTION
- Service 21
PID 67 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 N·m
- Unit
- N·m
In testing for 2011 to 2026.
MG2 carrier frequency AQUA_MG2_CARRIER
- Service 21
PID 7C - Module
7E2 → 7EA - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 Hz
- Unit
- Hz
In testing for 2011 to 2026.
MG2 control mode, pwm=0,variable pwm=1,rectangular wave=2 AQUA_MG2_CTRL_MODE_PWM_0_1_2
- Service 21
PID 68 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
MG2 gate status AQUA_MG2_GATE_STAT
- Service 21
PID 71 - Module
7E2 → 7EA - Every
5 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
MG2 inverter fail AQUA_MG2_INVERTER_FAIL
- Service 21
PID 78 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
MG2 inverter shutdown AQUA_MG2_INVERTER
- Service 21
PID 78 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
MG2 revolution AQUA_MG2_REVOLUTION
- Service 21
PID 62 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2011 to 2026.
MG2 temperature AQUA_MG2_T
- Service 21
PID 62 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
MG2 temperature at ignition on AQUA_MG2_T_AFTER_IG_ON
- Service 21
PID 62 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
MG2 temperature max AQUA_MG2_T_MAX
- Service 21
PID 62 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
MG2 torque AQUA_MG2_TQ_7E2
- Service 21
PID 68 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 N·m
- Unit
- N·m
In testing for 2011 to 2026.
MG2 torque execution value AQUA_MG2_TQ_EXECUTION
- Service 21
PID 68 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 N·m
- Unit
- N·m
In testing for 2011 to 2026.
Misfire RPM AQUA_MISFIRE_RPM_7E0
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Misfire test result, incomplete AQUA_MIS_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Model code_7e2, raw count AQUA_MODEL_CODE_7E2_RAW
- Service 21
PID C1 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 102,811,536 to 102,811,543 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Model year AQUA_MODEL_YEAR
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 1900 to 2155
- Unit
- Number
In testing for 2011 to 2026.
Motor generator 1 inverter gate AQUA_MG1_GATE
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 64 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Motor generator 1 inverter temperature AQUA_MG1_INV_T
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2011 to 2026.
Motor generator 1 speed AQUA_MG1_RPM
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -16383 to 49152 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Motor generator 1 torque AQUA_MG1_TQ
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- -500 to 7691.875 N·m
- Unit
- N·m
In testing for 2011 to 2026.
Motor generator 1 torque executed AQUA_MG1_TQ_EXEC
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- -512 to 508 N·m
- Unit
- N·m
In testing for 2011 to 2026.
Motor generator 2 inverter gate AQUA_MG2_GATE
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bit 65 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Motor generator 2 inverter temperature AQUA_MG2_INV_T
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2011 to 2026.
Motor generator 2 speed AQUA_MG2_RPM
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -16383 to 49152 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Motor generator 2 torque AQUA_MG2_TQ
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -500 to 7691.875 N·m
- Unit
- N·m
In testing for 2011 to 2026.
Motor generator 2 torque executed AQUA_MG2_TQ_EXEC
- Service 21
PID C4 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -512 to 508 N·m
- Unit
- N·m
In testing for 2011 to 2026.
Motor temperature 1 AQUA_MOTOR_T_1
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2011 to 2026.
Motor temperature 2 AQUA_MOTOR_T_2
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2011 to 2026.
Number of current code AQUA_NUM_CURRENT_CODE
- Service 21
PID E1 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Number of history code AQUA_NUM_HISTORY_CODE
- Service 21
PID E1 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
O2 heater b1s2_active AQUA_O2_HEATER_B1S2
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 68 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
O2 heater current val bank 1 sensor 2 AQUA_O2_HEATER_CURR_VAL
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 A
- Unit
- A
In testing for 2011 to 2026.
Open side malfunction on AQUA_OPEN_SIDE_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 145 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Output shaft speed AQUA_SPD_NOUT
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2011 to 2026.
OXS1, A/FS2 test result, incomplete AQUA_OXS1_FS2_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Oxygen sensor voltage, bank 1 sensor 1 AQUA_O2S11_V
- Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.27 V
- Unit
- V
In testing for 2011 to 2026.
Oxygen sensor voltage, bank 1 sensor 2 AQUA_O2S_B1S2
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
In testing for 2011 to 2026.
Park position switch terminal voltage AQUA_P_POS_SW_TERMINAL
- Service 21
PID 41 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2011 to 2026.
Power request AQUA_PWR_REQ
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 W
- Unit
- W
In testing for 2011 to 2026.
Power resource IB AQUA_POWER_RESOURCE_IB
- Service 21
PID 8A - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -327 to 655022 mA
- Unit
- mA
In testing for 2011 to 2026.
Purge cut vacuum switching valve duty AQUA_PURGE_CUT_VSV_DUTY
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2011 to 2026.
Racing operation AQUA_RACING_OPERATION
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 90 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Regulator pressure AQUA_REGULATOR_P
- Service 21
PID 53 - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -456.68 to 3294 kPa
- Unit
- kPa
In testing for 2011 to 2026.
Request engine run time AQUA_REQ_ENG_RUN_TIME
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2011 to 2026.
Request warm-up AQUA_REQ_WARM_UP
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 89 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Requested engine torque AQUA_REQ_ENG_TQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383
- Unit
- Number
In testing for 2011 to 2026.
SET/COAST switch AQUA_SET_COAST_SWITCH
- Service 21
PID 21 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 36 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Short circuit wave highest value AQUA_SHORT_CIRCUIT_WAVE
- Service 21
PID 9B - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.9799 V
- Unit
- V
In testing for 2011 to 2026.
Short term fuel trim, bank 1 AQUA_SHORT_FT_B1
Pelican can show this parameter as the short term fuel trim.
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2011 to 2026.
Short term fuel trim, bank 2 AQUA_SHORT_FT_B2
Pelican can show this parameter as the short term fuel trim.
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.21 %
- Unit
- %
In testing for 2011 to 2026.
Standby blower request status AQUA_STANDBY_BLOWER_REQ
- Service 21
PID 9B - Module
7E2 → 7EA - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Starter relay on AQUA_STARTER_RELAY_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 47 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Stroke open AQUA_STROKE_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
System guard on AQUA_SYSTEM_GUARD_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 144 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Target engine speed AQUA_ENG_RPM_TGT
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Temperature of battery 1 AQUA_TEMPERATURE_OF_BATT_TB1
- Service 21
PID CF - Module
7E2 → 7EA - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2011 to 2026.
Temperature of battery 2 AQUA_TEMPERATURE_OF_BATT_TB2
- Service 21
PID CF - Module
7E2 → 7EA - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2011 to 2026.
Temperature of battery 3 AQUA_TEMPERATURE_OF_BATT_TB3
- Service 21
PID CF - Module
7E2 → 7EA - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2011 to 2026.
Temperature of battery 4 AQUA_TEMPERATURE_OF_BATT_TB4
- Service 21
PID CF - Module
7E2 → 7EA - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2011 to 2026.
Temperature of battery 5 AQUA_TEMPERATURE_OF_BATT_TB5
- Service 21
PID CF - Module
7E2 → 7EA - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2011 to 2026.
Temperature of battery 6 AQUA_TEMPERATURE_OF_BATT_TB6
- Service 21
PID CF - Module
7E2 → 7EA - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2011 to 2026.
Temperature of battery 7 AQUA_TEMPERATURE_OF_BATT_TB7
- Service 21
PID CF - Module
7E2 → 7EA - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2011 to 2026.
Temperature of battery 8 AQUA_TEMPERATURE_OF_BATT_TB8
- Service 21
PID CF - Module
7E2 → 7EA - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2011 to 2026.
Throttle fully close learn AQUA_THROTTLE_FULLY_CLOSE
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2011 to 2026.
Throttle idle position on AQUA_THROTTLE_IDLE_POS_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 149 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Throttle motor current AQUA_THROTTLE_MOTOR
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 19.9 A
- Unit
- A
In testing for 2011 to 2026.
Throttle motor duty, close AQUA_THROTTLE_MOTOR_DUTY_CLOSE
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2011 to 2026.
Throttle motor duty, open AQUA_THROTTLE_MOTOR_DUTY_OPEN
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2011 to 2026.
Throttle position AQUA_THROTTLE_21
- Service 21
PID 11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2011 to 2026.
Throttle position AQUA_THROTTLE_POS
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2011 to 2026.
Throttle position command AQUA_THROTTLE_POS_COMMAND
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2011 to 2026.
Throttle position, number 1 AQUA_THROTTLE_POS_NUMBER_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2011 to 2026.
Throttle position, number 2 AQUA_THROTTLE_POS_NUMBER_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2011 to 2026.
Throttle require position AQUA_THROTTLE_REQUIRE_POS
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2011 to 2026.
Throttle sensor open position 1 AQUA_THROTTLE_SENS_OPEN_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2011 to 2026.
Throttle sensor open position 2 AQUA_THROTTLE_SENS_OPEN_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2011 to 2026.
Total fuel trim, bank 1 AQUA_TOT_FT_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -50 to 49.6 %
- Unit
- %
In testing for 2011 to 2026.
Transmission output shaft speed AQUA_TRANS_OUT_RPM
- Service 21
PID BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Turbine speed AQUA_SPD_NT
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Valvematic current angle AQUA_VALVEMATIC_CURRENT
- Service 21
PID 31 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
In testing for 2011 to 2026.
Valvematic, target angle AQUA_VALVEMATIC_TGT_ANG
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
In testing for 2011 to 2026.
Variable valve timing aim angle 1 AQUA_VARIABLE_VLV_TIM_AIM_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2011 to 2026.
Variable valve timing change angle 1 AQUA_VARIABLE_VLV_TIM_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 639 °
- Unit
- °
In testing for 2011 to 2026.
Variable valve timing control status 1 on AQUA_VARIABLE_VLV_TIM_1_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Variable valve timing oil control valve duty 1 AQUA_VARIABLE_VLV_TIM_OIL_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2011 to 2026.
Variable valve timing oil temperature AQUA_VVTOTConfirmed
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x7E = 126 → = 86 °C
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Vehicle speed AQUA_VSS_21
- Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2011 to 2026.
Vehicle speed sensor test result, incomplete AQUA_SPD_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Water pump run control duty AQUA_WATER_PMP_RUN_CTRL
- Service 21
PID 79 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 1593 %
- Unit
- %
In testing for 2011 to 2026.
Water pump running AQUA_WATER_PMP_RUNNING
- Service 21
PID 75 - Module
7E2 → 7EA - Every
5 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Misfires
All cylinders misfire count AQUA_ALL_CYLINDERS_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Cylinder #1 misfire count AQUA_CYL1_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Cylinder #2 misfire count AQUA_CYL2_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Cylinder #3 misfire count AQUA_CYL3_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Cylinder #4 misfire count AQUA_CYL4_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Misfire load AQUA_MISFIRE_LOAD_7E0
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.98
- Unit
- Number
In testing for 2011 to 2026.
Misfire margin AQUA_MISFIRE_MARGIN_7E0
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 %
- Unit
- %
In testing for 2011 to 2026.
Fluids
Distance since oil change AQUA_OIL_CHANGE_ODO
- Service 21
PID 41 - Module
7C0 → 7C8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 41038.272 km
- Unit
- km
In testing for 2011 to 2026.
Fuel
Fuel cut AQUA_FUEL_CUT
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Fuel cut AQUA_FUEL_CUT_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 121 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Fuel cut time AQUA_FUEL_CUT_TIME
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 68734.9511
- Unit
- Number
In testing for 2011 to 2026.
Fuel injection timing AQUA_FUEL_INJ_TIM
- Service 21
PID F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.64 ms
- Unit
- ms
In testing for 2011 to 2026.
Fuel level, volume AQUA_FLI_VOLConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 21
PID 29 - Module
7C0 → 7C8 - Every
5 s - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 21 gal
- Unit
- gal
0x25 = 37 → = 4.887715 gal
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Fuel pump/speed status on AQUA_FUEL_PMP_SPD_STAT_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Fuel remaining AQUA_FLV
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 1022 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 L
- Unit
- L
In testing for 2011 to 2026.
Target air-fuel equivalence ratio AQUA_LAMBDA_TARGET
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2011 to 2026.
Lights
Check engine SW AQUA_CHECK_ENGINE_LIGHT
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Hazard switch history AQUA_HAZARD_SWITCH_HISTORY
- Service 21
PID BC - Module
7B0 → 7B8 - Every
3600 s - Testing
Bit 2 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | INCOMPLETE | Incomplete |
1 | COMPLETE | Complete |
In testing for 2011 to 2026.
Oil pressure switch AQUA_EOP_LIGHT
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 35 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
P-seatbelt buckle SW AQUA_P_SEATBELT_BUCKLE_LIGHT
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Rheostat AQUA_RHEOSTAT
Higher values are brighter
- Service 21
PID 68 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Stop light AQUA_STOP_LIGHT_SW
- Service 21
PID 1F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Stop light AQUA_STOP_LIGHT_SWITCH
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Stop light relay AQUA_STOP_LIGHT_RELAY
- Service 21
PID 3C - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Tail cancel SW AQUA_TAIL_CANCEL_LIGHT
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Movement
Accelerator fully close learn 1 AQUA_ACCEL_FULLY_CLOSE_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 124.5 °
- Unit
- °
In testing for 2011 to 2026.
Accelerator fully close learn 2 AQUA_ACCEL_FULLY_CLOSE_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 124.5 °
- Unit
- °
In testing for 2011 to 2026.
Accelerator idle position on AQUA_ACCEL_IDLE_POS_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 148 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Accelerator pedal position 1 AQUA_ACCEL_PEDAL_POS_1
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2011 to 2026.
Accelerator pedal position 2 AQUA_ACCEL_PEDAL_POS_2
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2011 to 2026.
Accelerator position AQUA_ACCEL_POS
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2011 to 2026.
Accelerator sensor out, number 1 AQUA_ACCEL_SENS_OUT_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2011 to 2026.
Accelerator sensor out, number 2 AQUA_ACCEL_SENS_OUT_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2011 to 2026.
Average engine speed of all cylinders AQUA_AV_RPM_ALL_CYL
Pelican can show this parameter as the engine speed.
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Compressor speed AQUA_COMP_SPD
- Service 21
PID 49 - Module
7C4 → 7CC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Compressor, target speed AQUA_COMP_TGT_SPD
- Service 21
PID 4A - Module
7C4 → 7CC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Cruise control speed AQUA_CRUISE_CTRL_SPD
- Service 21
PID D3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2011 to 2026.
Engine speed AQUA_RPM_7E0
Pelican can show this parameter as the engine speed.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Engine speed of cylinder 1 AQUA_RPM_CYL_1
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Engine speed of cylinder 2 AQUA_RPM_CYL_2
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Engine speed of cylinder 3 AQUA_RPM_CYL_3
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Engine speed of cylinder 4 AQUA_RPM_CYL_4
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Engine speed_7e2 AQUA_RPM_7E2
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Front left wheel acceleration AQUA_FL_WHEEL_ACCELERATION
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
In testing for 2011 to 2026.
Front left wheel speed AQUA_TIRE_FL_SPDConfirmed
- Service 21
PID 03 - Module
7B0 - Every
250 ms - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Front left wheel speed? AQUA_FL_WHEEL_SPEED_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Front right wheel acceleration AQUA_FR_WHEEL_ACCELERATION
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
In testing for 2011 to 2026.
Front right wheel speed AQUA_TIRE_FR_SPDConfirmed
- Service 21
PID 03 - Module
7B0 - Every
250 ms - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Front right wheel speed? AQUA_FR_WHEEL_SPEED_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
High voltage, target engine speed AQUA_HIGH_V_TGT_RPM
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Minimum engine speed AQUA_MIN_RPM
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Rear left wheel acceleration AQUA_RL_WHEEL_ACCELERATION
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
In testing for 2011 to 2026.
Rear left wheel speed AQUA_TIRE_RL_SPDConfirmed
- Service 21
PID 03 - Module
7B0 - Every
250 ms - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Rear left wheel speed? AQUA_RL_WHEEL_SPEED_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Rear right wheel acceleration AQUA_RR_WHEEL_ACCELERATION
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -200.83 to 199.27 m/s²
- Unit
- m/s²
In testing for 2011 to 2026.
Rear right wheel speed AQUA_TIRE_RR_SPDConfirmed
- Service 21
PID 03 - Module
7B0 - Every
250 ms - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Rear right wheel speed? AQUA_RR_WHEEL_SPEED_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Speed AQUA_VSS_7C0
Pelican can show this parameter as the speed.
- Service 21
PID 21 - Module
7C0 → 7C8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2011 to 2026.
Vehicle speed AQUA_VSSConfirmed
Current vehicle speed.
Pelican can show this parameter as the speed.
- Service 21
PID 21 - Module
7B0 → 7B8 - Every
200 ms - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 323.85 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Vehicle speed AQUA_VSS_7E0
Pelican can show this parameter as the speed.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2011 to 2026.
Vehicle speed_7e2 AQUA_VSS_7E2
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2011 to 2026.
Orientation
Deceleration AQUA_DECEL
- Service 21
PID 05 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -18.18 to 18.18 m/s²
- Unit
- m/s²
In testing for 2011 to 2026.
Deceleration 2 AQUA_DECEL_2
- Service 21
PID 05 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -18.18 to 18.18 m/s²
- Unit
- m/s²
In testing for 2011 to 2026.
Deceleration open AQUA_DECELERATION_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Lateral g AQUA_LAT_GConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.5 to 2.5 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Longitudinal g AQUA_LNG_GConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.5 to 2.5 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Yaw rate value, degrees/sec AQUA_YAW_RATEConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 °
- Unit
- °
0x82 = 130 → = 2 °
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Yaw rate, error? AQUA_YAW_RATE_OPEN_ERROR
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Yaw rate, sensor 1 AQUA_YAW_1
- Service 21
PID 06 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2011 to 2026.
Yaw rate, sensor 2 AQUA_YAW_2
- Service 21
PID 06 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2011 to 2026.
Zero point of deceleration AQUA_ZP_DEC
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.56 to 2.54 g
- Unit
- g
In testing for 2011 to 2026.
Zero point of deceleration 2 AQUA_ZP_DEC2
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.56 to 2.54 g
- Unit
- g
In testing for 2011 to 2026.
Zero point of yaw rate AQUA_ZERO_POINT_OF_YAW_RATE
- Service 21
PID A1 - Module
7B0 → 7B8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2011 to 2026.
Zero point of yaw rate, degrees/sec AQUA_ZP_YAW
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2011 to 2026.
Seatbelts
Buckle switch, left side AQUA_BUCKLE_LS
- Service 21
PID 04 - Module
780 → 788 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Buckle switch, right side AQUA_BUCKLE_RS
- Service 21
PID 04 - Module
780 → 788 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Reverse beep AQUA_REVERSE_BEEP
- Service 21
PID AC - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- On or off
In testing for 2011 to 2026.
Seat belt beep, driver AQUA_SEAT_BELT_BEEP_DRIVER
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Seat belt beep, passenger AQUA_SEAT_BELT_BEEP_PASSENGER
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Seat belt beep, reminder AQUA_SEAT_BELT_BEEP_REMINDER
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Tires
Brake assist status AQUA_BA_CTRL_STATUS
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Front left wheel ABS status AQUA_FL_WHEEL_ABS_CTRL
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Front left wheel vehicle stability control status AQUA_FL_WHEEL_VSC_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Front right wheel ABS status AQUA_FR_WHEEL_ABS_CTRL
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Front right wheel cylinder open AQUA_FR_WHEEL_CYLINDER_OPEN
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2011 to 2026.
Front right wheel vehicle stability control status AQUA_FR_WHEEL_VSC_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Predictive brake assist status AQUA_PBA_CTRL_STATUS
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Rear left wheel ABS status AQUA_RL_WHEEL_ABS_CTRL
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Rear left wheel EBS status AQUA_RL_WHEEL_EBD_CTRL
Electronic brakeforce distribution
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Rear left wheel vehicle stability control status AQUA_RL_WHEEL_VSC_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Rear right wheel ABS status AQUA_RR_WHEEL_ABS_CTRL
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Rear right wheel EBS status AQUA_RR_WHEEL_EBD_CTRL
Electronic brakeforce distribution
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Rear right wheel vehicle stability control status AQUA_RR_WHEEL_VSC_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Torque converter turbine wheel speed AQUA_TQ_CONV_TURBINE_WHL
- Service 21
PID DA - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6 rpm
- Unit
- rpm
In testing for 2011 to 2026.
Traction control, engine status AQUA_TRC_TRAC__ENGINE_CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Traction control, status AQUA_TRC_TRAC__CTRL
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Wheel cylinder pressure AQUA_WHEEL_CYLINDER_PRESSURE
- Service 21
PID 07 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2011 to 2026.
Transmission
Boost converter temperature at ignition on AQUA_BOOST_CONV_T_AFTER_ON
- Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Boost converter temperature max AQUA_BOOST_CONV_T_MAX
- Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Boost converter temperature, lower AQUA_BOOST_CONV_T_LO
- Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Boost converter temperature, upper AQUA_BOOST_CONV_T_HI
- Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Converter carrier frequency, 9.55khz=0,9.13khz=1,8.71khz=2,8.29khz=3,7.87khz=4,7.45khz=5,4.8khz=6 AQUA_CONV_CARRIER_9_0_9_1_8_2_8_3_7_4_7_5_4_6
- Service 21
PID 7D - Module
7E2 → 7EA - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Converter fail AQUA_CONV_FAIL
- Service 21
PID 79 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Converter gate status AQUA_CONV_GATE_STAT
- Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 32 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Converter shutdown AQUA_CONV_SHUTDOWN
- Service 21
PID 79 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Current gear AQUA_GEAR_V2
- Service 21
PID DA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2011 to 2026.
Gear AQUA_GEAR
- Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20
- Unit
- Number
In testing for 2011, 2013 to 2026. Not supported for 2012.
Prohibit DC/DC converter signal AQUA_PROHIBIT_DC_DC_CONV
- Service 21
PID 75 - Module
7E2 → 7EA - Every
5 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Shift in drive AQUA_SHIFT_D
- Service 21
PID D3 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011 to 2026.
Shift position sensor voltage AQUA_SHIFT_POS_V
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2011 to 2026.
Shift select sensor main voltage AQUA_SELECT_MAIN_V
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2011 to 2026.
Shift select sensor sub voltage AQUA_SELECT_SUB_V
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2011 to 2026.
Shift sensor main AQUA_SHIFT_SENS_MAIN
- Service 21
PID 41 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.9799 V
- Unit
- V
In testing for 2011 to 2026.
Shift sensor main voltage AQUA_SHIFT_MAIN_V
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2011 to 2026.
Shift sensor select main AQUA_SHIFT_SENS_SELECT
- Service 21
PID 41 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.9799 V
- Unit
- V
In testing for 2011 to 2026.
Shift sensor select sub AQUA_SHIFT_SENS_SELECT_SUB
- Service 21
PID 41 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.9799 V
- Unit
- V
In testing for 2011 to 2026.
Shift sensor sub AQUA_SHIFT_SENS_SUB
- Service 21
PID 41 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.9799 V
- Unit
- V
In testing for 2011 to 2026.
Shift sensor sub voltage AQUA_SHIFT_SUB_V
- Service 21
PID C3 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2011 to 2026.
Torque converter and TE1 on AQUA_TQ_CONV_TE1_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Torque converter lock-up AQUA_TQC_LOCKUP
Engages a clutch inside the torque converter to create a direct connection between the engine and transmission, reducing slippage and improving efficiency.
- Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2011, 2013 to 2026. Not supported for 2012.
Transmission fluid temperature, variant 5 AQUA_ATF_T_V_5
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2011 to 2026.
Transmission fluid temperature, variant 8 AQUA_ATF_T_V_8
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2011 to 2026.
Transmission fluid temperature, variant 9 AQUA_ATF_T_V_9
- Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2011 to 2026.
Transmission fluid temperature, variant 10 AQUA_ATF_T_V_10_7E1
- Service 21
PID 82 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2011 to 2026.
Transmission fluid temperature, variant 11 AQUA_ATF_T_V_11
- Service 21
PID 82 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2011 to 2026.
Transmission fluid temperature, variant 12 AQUA_ATF_T_V_12
- Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2011 to 2026.
Transmission fluid temperature, variant 14 AQUA_ATF_T_V_14
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2011 to 2026.
Transmission fluid temperature, variant 14 AQUA_ATF_T_V_14_7E1
- Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2011 to 2026.
Transmission fluid temperature, variant 21 AQUA_ATF_T_V_21
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Transmission fluid temperature, variant 21 AQUA_ATF_T_V_21_7E1
- Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011 to 2026.
Transmission oil pressure calibration, complete AQUA_TRANS_OIL_PRESS
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2011 to 2026.
Transmission temperature, pan AQUA_ATF_PAN_T
- Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011, 2013 to 2026. Not supported for 2012.
Transmission temperature, torque converter AQUA_ATF_TQC_T
- Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2011, 2013 to 2026. Not supported for 2012.
Trips
DTC clear run distance AQUA_DTC_CLEAR_RUN_DIST
- Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2011 to 2026.
Odometer AQUA_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 21
PID 28 - Module
7E0 → 7E8 - Every
5 s - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x011A38 = 72248 → 72,248 km
Confirmed for 2012. In testing for 2011, 2013 to 2026.
Previous trip distance AQUA_PREV_TRIP_DSTConfirmed
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 2011, 2013 to 2026
Example reply from a 2012 Toyota Aqua.
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 km
- Unit
- km
0x00E9 = 233 → = 2.33 km
Confirmed for 2012. In testing for 2011, 2013 to 2026.