Parameters
The Suzuki Vitara has 128 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Air fuel sensor voltage, bank 1 sensor 1 VITARA_AFS_VOLTAGE_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.99 V
- Unit
- V
In testing for 1996 to 2026.
Battery voltage VITARA_BATTERY_VOLTAGE
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1996 to 2026.
Climate
Air conditioner feedback VITARA_AC_FB
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
- Range
- -40 to 39.99
- Unit
- Number
In testing for 1996 to 2026.
Ambient temperature for A/C VITARA_AC_AMB_T
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2026.
Communication with air conditioner VITARA_COMM_WITH_AIR_CONDITIONER
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Communication with HV VITARA_COMMUNICATION_WITH_HV
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Communication with valvematic VITARA_COMM_WITH_VALVEMATIC_COMM
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Control
A/C compressor VITARA_A_C_COMPRESSOR
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 64 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Communication with brake VITARA_COMMUNICATION_WITH_BRAKE
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Cruise control live brake cancel VITARA_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCH
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Electrical load signal 1 VITARA_ELECTRICAL_LOAD_SIGNAL_1
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Electrical load signal 2 VITARA_ELECTRICAL_LOAD_SIGNAL_2
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Ignition trigger count VITARA_IGNITION_TRIG_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65534
- Unit
- Number
In testing for 1996 to 2026.
Neutral position VITARA_NEUTRAL_POSITION_SW_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 53 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Pattern switch VITARA_PATTERN_SWITCH_PWR_M
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 42 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Power steering VITARA_POWER_STEERING_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Shift SW status, drive VITARA_SHIFT_SW_STATUS_D_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Shift SW status, neutral VITARA_SHIFT_SW_STATUS_N_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Shift SW status, parking VITARA_SHIFT_SW_STATUS_P_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Shift SW status, reverse VITARA_SHIFT_SW_STATUS_R_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Sports mode selection VITARA_SPORTS_MODE_SELECTION_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 32 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Sports shift down VITARA_SPORTS_SHIFT_DOWN_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 34 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Sports shift up VITARA_SPORTS_SHIFT_UP_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 33 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Starter control VITARA_STARTER_CONTROL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Starter signal VITARA_STARTER_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
TC VITARA_TC_TERMINAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 61 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Cruise control
Cancel switch VITARA_CC_CANCEL_SWITCH_ON
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 37 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Coast switch VITARA_CC_LIVE_SET_COAST_SWITCH_ON
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 36 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Cruise control indicator VITARA_CC_CCS_INDICATOR_M_CPU_ON
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Cruise control ready? VITARA_CC_CCS_READY_M_CPU_ON
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 1996 to 2026.
Cruise control speed VITARA_CC_S
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1996 to 2026.
Cruise control speed VITARA_CC_VSS
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1996 to 2026.
Cruise control, activated? VITARA_CC_CC_ON
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 1996 to 2026.
Cruise control, main switch VITARA_CC_MAIN_SW_M_CPU_ON
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Cruise control, on VITARA_CC_ON
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Requested driving force VITARA_CC_DRIVING_FORCE
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -51.2 to 50.8
- Unit
- Number
In testing for 1996 to 2026.
Resume/accelerate switch VITARA_CC_RES_ACC_SWITCH_ON
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 35 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
DTCs
2nd air monitor_avail VITARA_2ND_AIR_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
2nd air monitor_incmpl VITARA_2ND_AIR_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
A/C monitor_avail VITARA_A_C_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
A/C monitor_incmpl VITARA_A_C_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Catalyst monitor_avail VITARA_CATALYST_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Catalyst monitor_incmpl VITARA_CATALYST_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Complete parts monitor_avail VITARA_COMPLETE_PARTS_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
EGR/VVT monitor_avail VITARA_EGR_VVT_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
EGR/VVT monitor_incmpl VITARA_EGR_VVT_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
EVAP monitor_avail VITARA_EVAP_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
EVAP monitor_icmpl VITARA_EVAP_MONITOR_ICMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Fuel system monitor_avail VITARA_FUEL_SYSTEM_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Heated catalyst monitor_avail VITARA_HEATED_CATALYST_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Heated catalyst monitor_incmpl VITARA_HEATED_CATALYST_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
MIL VITARA_MIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
MIL ON run distance VITARA_MILON_RUN_DISTANCE
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 1996 to 2026.
Misfire monitor_avail VITARA_MISFIRE_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Number of emission DTC VITARA_NUMBER_OF_EMISSION_DTC
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 1996 to 2026.
O2S heater monitor_avail VITARA_O2S_A_FS_HEATER_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
O2S heater monitor_incmpl VITARA_O2S_A_FS_HEATER_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
O2S monitor_avail VITARA_O2S_A_FS_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
O2S monitor_incmpl VITARA_O2S_A_FS_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Running time from MIL ON VITARA_RUNNING_TIME_FROM_MIL_ON
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 1996 to 2026.
ECU
Engine module 2128 first value, raw VITARA_2128_RAW
- Service 21
PID 28 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777214
- Unit
- Number
In testing for 1996 to 2026.
Electrical
Electric load feedback VITARA_ELEC_LOAD_FB
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
- Range
- -40 to 39.99
- Unit
- Number
In testing for 1996 to 2026.
Engine
Accelerator sensor volt %, 1 VITARA_ACCEL_SENS_NO_1_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2026.
Accelerator sensor volt %, 2 VITARA_ACCEL_SENS_NO_2_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2026.
AF lambda, bank 1 sensor 1 VITARA_AF_LAMBDA_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 1996 to 2026.
Air fuel sensor current, bank 1 sensor 1 VITARA_AFS_CURRENT_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.99 mA
- Unit
- mA
In testing for 1996 to 2026.
Ambient temperature VITARA_AAT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2026.
Atmosphere pressure VITARA_ATMOSPHERE_PRESSURE
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 1996 to 2026.
Calculated load_7e0 VITARA_CALCULATED_LOAD_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2026.
Catalyst temperature B1S1 VITARA_CATALYST_T_B1S1
- Service 21
PID 05 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1996 to 2026.
Catalyst temperature B1S2 VITARA_CATALYST_T_B1S2
- Service 21
PID 05 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1996 to 2026.
Coolant temp VITARA_COOLANT_TEMP
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2026.
Engine oil temperature VITARA_EOT
Pelican can show this parameter as the engine oil temperature.
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2026.
Engine oil temperature, previous trip VITARA_PREV_TRIP_EOT
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2026.
Engine run time VITARA_ENGINE_RUN_TIME
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 1996 to 2026.
Engine start hesitation VITARA_ENG_START_HESIT
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 237 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Engine starting time VITARA_ENG_START_T
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 ms
- Unit
- ms
In testing for 1996 to 2026.
EVAP purge duty VITARA_EVAP_PURGE_DUTY
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2026.
Idle speed control feedback VITARA_ISC_FB
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
- Range
- -40 to 39.99
- Unit
- Number
In testing for 1996 to 2026.
Idle speed control flow VITARA_ISC_FLOW
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99
- Unit
- Number
In testing for 1996 to 2026.
Idle speed control learning value VITARA_ISC_LEARN
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
- Range
- -40 to 39.99
- Unit
- Number
In testing for 1996 to 2026.
Idle speed control position VITARA_ISC_POS
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
- Range
- 0 to 499.99 °
- Unit
- °
In testing for 1996 to 2026.
Ignition advance VITARA_IGN_ADVANCE
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 1996 to 2026.
Intake air VITARA_INTAKE_AIR
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2026.
Intake air temperature, previous trip VITARA_PREV_TRIP_IAT
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2026.
Long FT B1S1 VITARA_LONG_FT_B1S1
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.218 %
- Unit
- %
In testing for 1996 to 2026.
Low revolution control VITARA_LOW_RPM_CTRL
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 234 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Low revolution for engine start VITARA_LOW_RPM_START
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 236 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Manifold absolute pressure VITARA_MAP
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 1996 to 2026.
Mass air flow VITARA_MAF_V2
Pelican can show this parameter as the mass air flow.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 1996 to 2026.
Misfire RPM VITARA_MISFIRE_RPM_V2
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 1996 to 2026.
O2S, bank 1 sensor 2 VITARA_O2S_B1S2
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
In testing for 1996 to 2026.
Short FT B1S1 VITARA_SHORT_FT_B1S1
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.218 %
- Unit
- %
In testing for 1996 to 2026.
Starter count VITARA_STARTER_CNT
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 33 to 39 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 1996 to 2026.
Throttle motor DUTY VITARA_THROTTLE_MOTOR_DUTY
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2026.
Throttle position VITARA_TPS
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
- Range
- 0 to 499.99 °
- Unit
- °
In testing for 1996 to 2026.
Throttle sensor position VITARA_THROTTLE_SENSOR_POSITION
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2026.
Throttle sensor volt %, 1 VITARA_THROTTLE_SENSOR_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2026.
Throttle sensor volt %, 2 VITARA_THROTTL_SENSOR_2_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2026.
Time after DTC cleared VITARA_TIME_AFTER_DTC_CLEARED
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 1996 to 2026.
Variable valve timing advance fail VITARA_VVT_ADV_FAIL
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 235 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Variable valve timing oil temperature VITARA_VVTOT
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2026.
Vehicle load VITARA_VEHICLE_LOAD
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2026.
Warm-up cycle cleared DTC VITARA_WARMUP_CYCLE_CLEARED_DTC
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2026.
Misfires
All cylinders misfire count VITARA_ALL_CYLINDERS_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 254
- Unit
- Number
In testing for 1996 to 2026.
Cylinder #1 misfire count VITARA_CYL1_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 254
- Unit
- Number
In testing for 1996 to 2026.
Cylinder #2 misfire count VITARA_CYL2_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 254
- Unit
- Number
In testing for 1996 to 2026.
Cylinder #3 misfire count VITARA_CYL3_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 254
- Unit
- Number
In testing for 1996 to 2026.
Cylinder #4 misfire count VITARA_CYL4_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 254
- Unit
- Number
In testing for 1996 to 2026.
Misfire load VITARA_MISFIRE_LOAD_V2
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.98
- Unit
- Number
In testing for 1996 to 2026.
Misfire margin VITARA_MISFIRE_MARGIN_V2
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 %
- Unit
- %
In testing for 1996 to 2026.
Fuel
Immobilizer fuel cut VITARA_IMMOB_FUEL_CUT
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 32 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Target air-fuel ratio VITARA_TARGET_AIR_FUEL_RATIO
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 1996 to 2026.
Lights
Cruise control stop light switch 1 VITARA_CC_STOP_LIGHT_SWITCH_1_ON
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 32 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Cruise control stop light switch 2 VITARA_CC_STOP_LIGHT_SWITCH_2_ON
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 33 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Stop light VITARA_STOP_LIGHT_SWITCH
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2026.
Movement
Engine speed VITARA_ENGINE_SPEED
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 rpm
- Unit
- rpm
In testing for 1996 to 2026.
Engine speed, starter off VITARA_ENG_SPD_START_OFF
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 1996 to 2026.
Vehicle speed VITARA_VEHICLE_SPEED_V2
Pelican can show this parameter as the speed.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1996 to 2026.
Transmission
Current gear VITARA_GEAR_V3
- Service 21
PID DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2026.
Gear VITARA_GEAR
- Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20
- Unit
- Number
In testing for 1996 to 2026.
Neutral control VITARA_NEUTRAL_CTRL
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 233 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Neutral range status VITARA_N_RANGE_STS
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 232 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Torque converter lock-up VITARA_TQC_LOCKUP
Engages a clutch inside the torque converter to create a direct connection between the engine and transmission, reducing slippage and improving efficiency.
- Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2026.
Transmission temperature, pan VITARA_ATF_PAN_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2026.
Transmission temperature, torque converter VITARA_ATF_TQC_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2026.
Trips
Ambient temperature, previous trip VITARA_PREV_TRIP_AMB_T
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2026.
Previous trip distance VITARA_PREV_TRIP_DST
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 km
- Unit
- km
In testing for 1996 to 2026.