Parameters
The Subaru Legacy has 300 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery current LEGACY_12V_CConfirmed
- Service 22
DID 1135 - Module
7A2 → 7AA - Every
500 ms - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 mA
- Unit
- mA
0xFD = 253 → = 125 mA
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
12V battery temperature LEGACY_12V_TConfirmed
- Service 22
DID 1136 - Module
7A2 - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x8C = 140 → = 100 °C
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Battery charge/discharge current LEGACY_BAT_CHARGE_DISCHARGE_CURRENTConfirmed
- Service 22
DID 1322 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -2000 to 4292967.295 A
- Unit
- A
0x001DDD8A = 1957258 → = -42.742 A
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Battery terminal voltage LEGACY_BAT_TERMINAL_VOLTAGEConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 1321 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
0x2DF4 = 11764 → = 11.764 V
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Estimated battery temperature LEGACY_ESTIMATED_BAT_TConfirmed
- Service 22
DID 1323 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 32727.5 °C
- Unit
- °C
0x003A = 58 → = -11 °C
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
High voltage battery cooling fan duty output LEGACY_HVBAT_COOLING_FAN_DUTY
- Service 22
DID 1084 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2015, 2017 to 2021, 2023 to 2025. Not supported for 2016, 2022.
High voltage battery cooling fan duty, target LEGACY_HVBAT_COOLING_FAN_TGT
- Service 22
DID 1082 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2015, 2017 to 2021, 2023 to 2025. Not supported for 2016, 2022.
High voltage battery cooling fan speed LEGACY_HVBAT_COOLING_FAN
- Service 22
DID 1081 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 1996 to 2015, 2017 to 2021, 2023 to 2025. Not supported for 2016, 2022.
Mass airflow sensor voltage LEGACY_MAF_VOLTAGEConfirmed
- Service 22
DID 10A1 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5.1 V
- Unit
- V
0x00 = 0 → = 0 V
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Remaining battery capacity LEGACY_REMAINING_BAT_CAPACITYConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID 1324 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2015, 2017 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0022 = 34 → = 3.4 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2016, 2022. Not supported for 2004, 2011.
Throttle motor voltage LEGACY_THROTTLE_MOTOR_VConfirmed
- Service 22
DID 1275 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20.4 V
- Unit
- V
0x98 = 152 → = 12.16 V
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Climate
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2016, 2022. Supported for 2011.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2011, 2016 to 2017. Supported for 2020, 2022, 2024.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011, 2016 to 2017. Supported for 2020, 2022, 2024.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011, 2016 to 2017.
Accelerator pedal position LEGACY_ACC_POSConfirmed
- Service 22
DID 10A6 - Module
7A2 → 7AA - Every
250 ms - Testing for 1996 to 2015, 2017 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2016, 2022. Not supported for 2004, 2011.
Brake pedal position LEGACY_BRAKE_PRESSEDConfirmed
- Service 22
DID 1233 - Module
7E0 → 7E8 - Every
250 ms - Testing for 1996 to 2015, 2017 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2016, 2022. In testing for 1996 to 2015, 2017 to 2021, 2023 to 2025.
Brake switch LEGACY_BRAKE_SWITCHConfirmed
- Service 22
DID 1233 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2015, 2017 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2016, 2022. Not supported for 2004, 2011.
Clutch pedal position LEGACY_CLUTCH_PRESSED
- Service 22
DID 122F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2025.
Clutch switch LEGACY_CLUTCH_SWITCHConfirmed
- Service 22
DID 122F - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Knocking signal LEGACY_KNOCKING_SIGNALConfirmed
- Service 22
DID 11D0 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
0x00 = 0 → 0 °
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Relative throttle position TP_RSAE J1979Confirmed
Relative or 'learned' throttle position.
- Service 01
PID 45 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2017. Supported for 2011.
Steering wheel angle LEGACY_STEER_ANGLEConfirmed
- Service 22
DID 1029 - Module
7B0 → 7B8 - Every
250 ms - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32767 to 32767 °
- Unit
- °
0x0000 = 0 → 0 °
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Steering wheel angle LEGACY_STEER_ANGLE_7B0
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -3276 to 3276.7 °
- Unit
- °
In testing for 1996 to 2025.
Steering wheel angle, v2 LEGACY_STEER_ANGLE_746Confirmed
- Service 22
DID 1032 - Module
746 → 74E - Every
1 s - Testing for 1996 to 2015, 2017 to 2025
Example reply from a 2016 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -640 to 635 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2016. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2022, 2024.
Pedals
Accelerator pedal position (relative) APP_RSAE J1979Confirmed
- Service 01
PID 5A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2017. Supported for 2011.
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2017. Supported for 2011.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2017. Supported for 2011.
Cruise control
Cruise control cancel switch LEGACY_CC_CANCEL_SWITCHConfirmed
- Service 22
DID 124A - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Cruise control main toggle switch LEGACY_CC_MAIN_TOGGLE_SWITCHConfirmed
- Service 22
DID 1234 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Cruise control resume/accelerate switch LEGACY_CC_RESUME_ACCELERATE_SWITCHConfirmed
- Service 22
DID 1232 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Cruise control set/coast switch LEGACY_CC_SET_COAST_SWITCHConfirmed
- Service 22
DID 1231 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Cruise control speed LEGACY_CC_SPD
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1996 to 2025.
Cruise speed, set LEGACY_CRUISE_VSS_TConfirmed
- Service 22
DID 10E3 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2011, 2016 to 2017, 2022, 2024. Supported for 2020.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed
Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.
- Service 01
PID 4E - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2016. Supported for 2011.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 4D - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2016. Supported for 2011.
Status
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2011, 2017, 2020, 2022, 2024.
ECU
A/F sensor #1 LEGACY_A_F_SENSOR_1Confirmed
- Service 22
DID 10BE - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
0x59 = 89 → = 0.694549
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Actual line pressure LEGACY_ACTUAL_LINE_PRESSUREConfirmed
- Service 22
DID 12B1 - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25.6
- Unit
- Raw value
0x0000 = 0 → = 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Actual primary pressure LEGACY_ACTUAL_PRIMARY_PRESSUREConfirmed
- Service 22
DID 1141 - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25.6
- Unit
- Raw value
0x0000 = 0 → = 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Actual secondary pressure LEGACY_ACTUAL_SECONDARY_PRESSUREConfirmed
- Service 22
DID 113A - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25.6
- Unit
- Raw value
0x0000 = 0 → = 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
All-wheel drive solenoid actual current LEGACY_AWD_SOLENOID_ACTUAL_CURRENTConfirmed
- Service 22
DID 12B5 - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
0x0000 = 0 → 0 mA
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
All-wheel drive solenoid set current LEGACY_AWD_SOLENOID_SET_CURRENTConfirmed
- Service 22
DID 12B4 - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
0x0000 = 0 → 0 mA
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Alternator duty LEGACY_ALTERNATOR_DUTYConfirmed
- Service 22
DID 10B2 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
0x0A = 10 → 10 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Canister purge control valve duty cycle LEGACY_CPC_VALVE_DUTY_CYCLEConfirmed
- Service 22
DID 10AE - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2015, 2017 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2016, 2022. Not supported for 2004, 2011.
Cylinder monitor #1 LEGACY_MONITOR_1Confirmed
- Service 22
DID 1314 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
0x0000 = 0 → = 0 rpm
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Cylinder monitor #2 LEGACY_MONITOR_2Confirmed
- Service 22
DID 1315 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
0x0000 = 0 → = 0 rpm
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Cylinder monitor #3 LEGACY_MONITOR_3Confirmed
- Service 22
DID 1316 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
0x0000 = 0 → = 0 rpm
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Cylinder monitor #4 LEGACY_MONITOR_4Confirmed
- Service 22
DID 1317 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
0x0000 = 0 → = 0 rpm
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Drive motor inverter input HV sensor LEGACY_DRIVEMOTOR_INVERTER_INPUT_HV_SENSOR
- Service 22
DID 1063 - Module
7E6 → 7EE - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 V
- Unit
- V
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016, 2024.
Drive motor output power LEGACY_DRIVEMOTOR_OUTPUT_POWER
- Service 22
DID 1055 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 W
- Unit
- W
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Drive motor torque lower limit LEGACY_DRIVEMOTOR_TORQUE_LOWER_LIMIT
- Service 22
DID 105E - Module
7E6 → 7EE - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 N·m
- Unit
- N·m
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016, 2024.
Drive motor torque output actual LEGACY_DRIVEMOTOR_TORQUE_OUTPUT_ACTUAL
- Service 22
DID 1052 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Drive motor torque target LEGACY_DRIVEMOTOR_TORQUE_TARGET
- Service 22
DID 1057 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Drive motor torque upper limit LEGACY_DRIVEMOTOR_TORQUE_UPPER_LIMIT
- Service 22
DID 105D - Module
7E6 → 7EE - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 N·m
- Unit
- N·m
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016, 2024.
Electric waste gate valve actual position value LEGACY_EWG_VALVE_ACTUAL_POSITIONConfirmed
- Service 22
DID 10D4 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2023, 2025
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -10 to 30 mm
- Unit
- mm
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Electric waste gate valve request position value LEGACY_EWG_VALVE_REQUEST_POSITIONConfirmed
- Service 22
DID 10D3 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2023, 2025
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -10 to 30 mm
- Unit
- mm
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Engine starting time LEGACY_ENGINE_STARTING_TIMEConfirmed
- Service 22
DID 129C - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Engine torque target LEGACY_ENGINE_TORQUE_TARGET
- Service 22
DID 2006 - Module
7E7 → 7EF - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1000 to 5553.5 N·m
- Unit
- N·m
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016, 2024.
Exhaust gas recirculation steps LEGACY_EGR_STEPSConfirmed
- Service 22
DID 10B1 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Exhaust gas recirculation valve opening angle LEGACY_EGR_VALVE_OPENING_ANGLE
- Service 22
DID 111C - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °
- Unit
- °
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Exhaust OCV duty left LEGACY_EXHAUST_OCV_DUTY_LEFTConfirmed
- Service 22
DID 10EF - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Exhaust OCV duty right LEGACY_EXHAUST_OCV_DUTY_RIGHTConfirmed
- Service 22
DID 10EE - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Final injection amount LEGACY_FINAL_INJECTION_AMOUNT_MM_ST
- Service 22
DID 1116 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Final main injection period LEGACY_FINAL_MAIN_INJECTION_PERIOD
- Service 22
DID 1162 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Glow relay switch LEGACY_GLOW_RELAY_SWITCH
- Service 22
DID 124F - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Individual pump difference learning value LEGACY_INDIVIDUAL_PUMP_DIFFERENCE_LEARNING_VALUE
- Service 22
DID 1161 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Injector learning switch LEGACY_INJECTOR_LEARNING_SWITCH
- Service 22
DID 1254 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Intake VVT advance angle left LEGACY_INTAKE_VVT_ADVANCE_LEFTConfirmed
- Service 22
DID 10B5 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °
- Unit
- °
0x10 = 16 → = -34 °
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Intake VVT advance angle right LEGACY_INTAKE_VVT_ADVANCE_RIGHTConfirmed
- Service 22
DID 10B4 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °
- Unit
- °
0x12 = 18 → = -32 °
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Interior heater LEGACY_INTERIOR_HEATER
- Service 22
DID 112C - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Lin. solenoid actual current LEGACY_LIN_SOLENOID_ACTUAL_CURRENTConfirmed
- Service 22
DID 12B2 - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
0x0000 = 0 → 0 mA
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Lock up duty ratio LEGACY_LOCK_UP_DUTY_RATIOConfirmed
- Service 22
DID 10C8 - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Micro-quantity-injection final learning value #1 cylinder #1 LEGACY_MQI_FLV_1_1
- Service 22
DID 1158 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #1 cylinder #2 LEGACY_MQI_FLV_1_2
- Service 22
DID 1159 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #1 cylinder #3 LEGACY_MQI_FLV_1_3
- Service 22
DID 115A - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #1 cylinder #4 LEGACY_MQI_FLV_1_4
- Service 22
DID 115B - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #2 cylinder #1 LEGACY_MQI_FLV_2_1
- Service 22
DID 1158 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #2 cylinder #2 LEGACY_MQI_FLV_2_2
- Service 22
DID 1159 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #2 cylinder #3 LEGACY_MQI_FLV_2_3
- Service 22
DID 115A - Module
7A2 → 7AA - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #2 cylinder #4 LEGACY_MQI_FLV_2_4
- Service 22
DID 115B - Module
7A2 → 7AA - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #3 cylinder #1 LEGACY_MQI_FLV_3_1
- Service 22
DID 1158 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #3 cylinder #2 LEGACY_MQI_FLV_3_2
- Service 22
DID 1159 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #3 cylinder #3 LEGACY_MQI_FLV_3_3
- Service 22
DID 115A - Module
7A2 → 7AA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #3 cylinder #4 LEGACY_MQI_FLV_3_4
- Service 22
DID 115B - Module
7A2 → 7AA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #4 cylinder #1 LEGACY_MQI_FLV_4_1
- Service 22
DID 1158 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #4 cylinder #2 LEGACY_MQI_FLV_4_2
- Service 22
DID 1159 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #4 cylinder #3 LEGACY_MQI_FLV_4_3
- Service 22
DID 115A - Module
7A2 → 7AA - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #4 cylinder #4 LEGACY_MQI_FLV_4_4
- Service 22
DID 115B - Module
7A2 → 7AA - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #5 cylinder #1 LEGACY_MQI_FLV_5_1
- Service 22
DID 1158 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #5 cylinder #2 LEGACY_MQI_FLV_5_2
- Service 22
DID 1159 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #5 cylinder #3 LEGACY_MQI_FLV_5_3
- Service 22
DID 115A - Module
7A2 → 7AA - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Micro-quantity-injection final learning value #5 cylinder #4 LEGACY_MQI_FLV_5_4
- Service 22
DID 115B - Module
7A2 → 7AA - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Mileage after injector learning LEGACY_MILEAGE_AFTER_INJECTOR_LEARNING
- Service 22
DID 112A - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 327675 km
- Unit
- km
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Mileage after injector replacement LEGACY_MILEAGE_AFTER_INJECTOR_REPLACEMENT
- Service 22
DID 112B - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 327675 km
- Unit
- km
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Oil control valve duty left LEGACY_OCV_DUTY_LEFTConfirmed
- Service 22
DID 10B7 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Oil control valve duty right LEGACY_OCV_DUTY_RIGHTConfirmed
- Service 22
DID 10B6 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Oil dilution amount LEGACY_OIL_DILUTION_AMOUNT
- Service 22
DID 1189 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275
- Unit
- Number
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Oil dilution ratio LEGACY_OIL_DILUTION_RATIO
- Service 22
DID 114E - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Oil level switch LEGACY_OIL_LEVEL_SWITCHConfirmed
- Service 22
DID 124C - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Oil supply value, duty left LEGACY_OSV_DUTY_LEFTConfirmed
- Service 22
DID 10E9 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Oil supply value, duty right LEGACY_OSV_DUTY_RIGHTConfirmed
- Service 22
DID 10E8 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Quantity correction cylinder #1 LEGACY_QUANTITY_CORRECTION_1
- Service 22
DID 112D - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Quantity correction cylinder #2 LEGACY_QUANTITY_CORRECTION_2
- Service 22
DID 112E - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Quantity correction cylinder #3 LEGACY_QUANTITY_CORRECTION_3
- Service 22
DID 112F - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Quantity correction cylinder #4 LEGACY_QUANTITY_CORRECTION_4
- Service 22
DID 1130 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Radiator fan control LEGACY_RADIATOR_FANConfirmed
- Service 22
DID 10AB - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 %
- Unit
- %
0x00 = 0 → 0 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Roughness monitor #1 LEGACY_ROUGHNESS_MONITOR_1Confirmed
- Service 22
DID 110B - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Roughness monitor #2 LEGACY_ROUGHNESS_MONITOR_2Confirmed
- Service 22
DID 110C - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Roughness monitor #3 LEGACY_ROUGHNESS_MONITOR_3Confirmed
- Service 22
DID 110D - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Roughness monitor #4 LEGACY_ROUGHNESS_MONITOR_4Confirmed
- Service 22
DID 110E - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2015, 2017 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2016, 2022. Not supported for 2004, 2011.
Secondary actual current LEGACY_SECONDARY_ACTUAL_CURRENTConfirmed
- Service 22
DID 113C - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
0x0000 = 0 → 0 mA
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Secondary set current LEGACY_SECONDARY_SET_CURRENTConfirmed
- Service 22
DID 113B - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
0x0000 = 0 → 0 mA
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Target intake manifold pressure LEGACY_TARGET_INTAKE_MANIFOLD_PRESSURE
- Service 22
DID 1118 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 50 kPa
- Unit
- kPa
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Throttle motor duty LEGACY_THROTTLE_MOTOR_DUTYConfirmed
- Service 22
DID 10DE - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.92 %
- Unit
- %
0x32 = 50 → = -60.8 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Transfer duty ratio LEGACY_TRANSFER_DUTY_RATIO
- Service 22
DID 10C9 - Module
7A3 → 7AB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Engine
Absolute evap system vapor pressure EVAP_VPASAE J1979Confirmed
Normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Service 01
PID 53 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 327.675 kPa
- Unit
- kPa
Confirmed for 2017. Supported for 2016.
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2011, 2016 to 2017, 2022. Supported for 2020, 2024.
Ambient temperature for control LEGACY_AMBIENT_T_CTRLConfirmed
- Service 22
DID 12D1 - Module
7E0 → 7E8 - Every
5 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 87.5 °C
- Unit
- °C
0x78 = 120 → = 20 °C
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Ambient temperature for sensor signal LEGACY_AMBIENT_T_SENS_SIGConfirmed
- Service 22
DID 12CE - Module
7E0 → 7E8 - Every
5 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 87.5 °C
- Unit
- °C
0x78 = 120 → = 20 °C
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011, 2016 to 2017, 2022. Supported for 2020, 2024.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2011, 2016 to 2017, 2022. Supported for 2020, 2024.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017. Supported for 2011, 2016.
Continuously variable transmission temperature LEGACY_CVT_TConfirmed
- Service 22
DID 10D2 - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
0x26 = 38 → = -12 °C
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Coolant temperature LEGACY_ECT
- Service 22
DID 0005 - Module
7A2 → 7AA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Coolant temperature LEGACY_ECT_7E0
- Service 22
DID 0005 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Cumulative ash ratio LEGACY_CUM_ASH_RAT
- Service 22
DID 1149 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Cumulative ash ratio LEGACY_CUM_ASH_RAT_7E0
- Service 22
DID 1149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 1996 to 2021, 2023 to 2025. Not supported for 2022.
Drive motor inverter temperature a LEGACY_DRIVEMOTOR_INVERTER_T_A
- Service 22
DID 1066 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Drive motor inverter temperature b LEGACY_DRIVEMOTOR_INVERTER_T_B
- Service 22
DID 1067 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Drive motor inverter temperature c LEGACY_DRIVEMOTOR_INVERTER_T_C
- Service 22
DID 1068 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Drive motor temperature a LEGACY_DRIVEMOTOR_T_A
- Service 22
DID 106D - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -55 to 200 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Drive motor temperature b LEGACY_DRIVEMOTOR_T_B
- Service 22
DID 106E - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -55 to 200 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
EGR error EGR_ERRSAE J1979Confirmed
- Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
Electric load feedback value LEGACY_ELEC_LOAD_FEEDBACKConfirmed
- Service 22
DID 128D - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2.55 g/s
- Unit
- g/s
0x00 = 0 → = 0 g/s
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Electric waste gate valve position sensor learning value at fully-closed position LEGACY_EWG_VALVE_POSITION_SENSOR_LEARNING_CLOSEDConfirmed
- Service 22
DID 10D2 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2023, 2025
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -10 to 29 mm
- Unit
- mm
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2011, 2016 to 2017. Supported for 2024.
Engine oil temperature EOTSAE J1979Confirmed
Pelican can show this parameter as the engine oil temperature.
- Service 01
PID 5C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2016 to 2017, 2022.
Engine oil temperature LEGACY_EOT
Pelican can show this parameter as the engine oil temperature.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 215 °C
- Unit
- °C
In testing for 1996 to 2025.
Engine oil temperature LEGACY_EOT_7E0
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2025.
Engine oil temperature LEGACY_EOT_V2
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 10E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
Estimated catalyst temperature LEGACY_ESTIMATED_CATALYST_T
- Service 22
DID 114B - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 1235 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Exhaust gas recirculation target valve opening angle LEGACY_EGR_TARGET_VALVE_OPENING_ANGLE
- Service 22
DID 111B - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °
- Unit
- °
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Exhaust gas temperature, catalyst inlet LEGACY_EGT_AT_CATALYST_INLET
- Service 22
DID 003C - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Exhaust VVT cleaning self-recovery counter LEGACY_EXH_VVT_CLEANINGConfirmed
- Service 22
DID 11BF - Module
7E0 → 7E8 - Every
3600 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Exhaust VVT retard angle left LEGACY_EXH_VVT_RETARD_ANG_LEFTConfirmed
- Service 22
DID 10ED - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °
- Unit
- °
0x32 = 50 → = 0 °
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Exhaust VVT retard angle right LEGACY_EXH_VVT_RETARD_ANGConfirmed
- Service 22
DID 10EC - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °
- Unit
- °
0x32 = 50 → = 0 °
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Exhaust VVT retard, target angle left LEGACY_EXH_VVT_RETARD_TGT_ANGConfirmed
- Service 22
DID 1292 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °
- Unit
- °
0x32 = 50 → = 0 °
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Exhaust VVT retard, target angle right LEGACY_EXH_VVT_RETARD_TGTConfirmed
- Service 22
DID 1291 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °
- Unit
- °
0x32 = 50 → = 0 °
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Fuel temperature LEGACY_FUEL_T
- Service 22
DID 10A7 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Idle A/C load correction LEGACY_IDLE_AC_LOAD_CORRConfirmed
- Service 22
DID 128C - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2.55 g/s
- Unit
- g/s
0x00 = 0 → = 0 g/s
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Idle dirty throttle correction LEGACY_IDLE_DIRTY_THROTTLEConfirmed
- Service 22
DID 128E - Module
7E0 → 7E8 - Every
250 ms - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -300 to 355 g/s
- Unit
- g/s
0x75BE = 30142 → = 1.42 g/s
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Idle mass air flow LEGACY_IDLE_MAFConfirmed
- Service 22
DID 1289 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 g/s
- Unit
- g/s
0x01B1 = 433 → = 4.33 g/s
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Idle mass air flow feedback correction LEGACY_IDLE_MAF_FEEDBACKConfirmed
- Service 22
DID 128A - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -300 to 355 g/s
- Unit
- g/s
0x7530 = 30000 → = 0 g/s
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Idle speed control learning value LEGACY_IDLE_SPD_CTRLConfirmed
- Service 22
DID 128B - Module
7E0 → 7E8 - Every
3600 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -300 to 355 g/s
- Unit
- g/s
0x752C = 29996 → = -0.04 g/s
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Inlet air temperature LEGACY_INLET_AIR_T
- Service 22
DID 307A - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -30 to 300 °F
- Unit
- °F
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Inlet air temperature, after air filter LEGACY_INLET_AIR_T_AFTER_AIR_FILTER
- Service 22
DID 111F - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Intake air temperature IATSAE J1979Confirmed
- Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022.
Intake VVT advance, target angle left LEGACY_INT_VVT_ADVANCE_TGT_ANGConfirmed
- Service 22
DID 1290 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °
- Unit
- °
0x28 = 40 → = -10 °
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Intake VVT advance, target angle right LEGACY_INT_VVT_ADVANCE_TGTConfirmed
- Service 22
DID 128F - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °
- Unit
- °
0x1E = 30 → = -20 °
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Intake VVT cleaning self-recovery counter LEGACY_INT_VVT_CLEANINGConfirmed
- Service 22
DID 11BE - Module
7E0 → 7E8 - Every
3600 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Inverter temperature estimated LEGACY_INVERTER_T_ESTIMATED
- Service 22
DID 1065 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
Main throttle sensor LEGACY_MAIN_THROTTLE_SENSConfirmed
- Service 22
DID 1277 - Module
7E0 → 7E8 - Every
250 ms - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5.1 V
- Unit
- V
0x23 = 35 → = 0.7 V
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Mass air flow, average LEGACY_MAF_AVGConfirmed
- Service 22
DID 12ED - Module
7A2 → 7AA - Every
250 ms - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
0x0000 = 0 → = 0 g/s
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Primary boost control LEGACY_PRIMARY_BOOST_CTRL
- Service 22
DID 10AC - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2021, 2023 to 2025. Not supported for 2022.
Primary boost control LEGACY_PRIMARY_BOOST_CTRL_7E0
- Service 22
DID 10AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2021, 2023 to 2025. Not supported for 2022.
Purge density learn value LEGACY_PURGE_DENSITY_LEARNConfirmed
- Service 22
DID 1295 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1996 to 2021, 2023 to 2025
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.1999 %
- Unit
- %
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2011, 2016 to 2017, 2022. Supported for 2020, 2024.
Sub throttle sensor LEGACY_SUB_THROTTLE_SENSConfirmed
- Service 22
DID 1276 - Module
7E0 → 7E8 - Every
250 ms - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5.1 V
- Unit
- V
0x4E = 78 → = 1.56 V
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
Transmission fluid temperature LEGACY_ATF_T
- Service 22
DID 106B - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Transmission lock-up LEGACY_TRANS_LOCK_UPConfirmed
- Service 22
DID 1299 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x04 = 4 → 4 %
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Trip counter LEGACY_TRIP_CNTConfirmed
- Service 22
DID 101E - Module
7E0 → 7E8 - Every
3600 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x2FE4 = 12260 → 12,260
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Tumble generator valve position sensor left LEGACY_TUMBLE_GEN_VLV_POS_SENSConfirmed
- Service 22
DID 10B0 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5.1 V
- Unit
- V
0x38 = 56 → = 1.12 V
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Tumble generator valve position sensor right LEGACY_TUMBLE_GEN_VLV_POSConfirmed
- Service 22
DID 10AF - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5.1 V
- Unit
- V
0x37 = 55 → = 1.1 V
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2017. Supported for 2011, 2016.
Variable valve timing oil temperature LEGACY_VVTOT
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2025.
AuxInputs
Auto Trans Neutral Drive Status N/D_STATSAE J1979Confirmed
- Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016.
Glow plug lamp status GPL_STATSAE J1979Confirmed
- Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016.
Manual Trans Neutral Gear Status N/G_STATSAE J1979Confirmed
- Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016.
Power Take Off (PTO) Output Status PTO_STAT_AUXSAE J1979Confirmed
- Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016.
Recommended gear GEAR_RCMDSAE J1979Confirmed
- Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 11 of the reply, 4 bits.
- Formula
- Range
- 0 to 15
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016.
AuxInputs › Internal
Auto trans neutral drive status supported N/D_SUPSAE J1979Confirmed
- Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016.
Glow plug lamp status supported GPL_SUPSAE J1979Confirmed
- Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016.
Manual trans neutral gear status supported N/G_SUPSAE J1979Confirmed
- Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016.
Power Take Off (PTO) output status supported PTO_SUPSAE J1979Confirmed
- Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016.
Recommended gear supported GEAR_SUPSAE J1979Confirmed
- Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016.
OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2022. Supported for 2011, 2016, 2024.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2017, 2022. Supported for 2011, 2016, 2020, 2024.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
SHRTFT associated with O2S12 SHRTFT12SAE J1979Confirmed
- Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2017. Supported for 2011, 2016, 2020, 2022, 2024.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2022. Supported for 2011, 2016, 2024.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2017, 2022. Supported for 2011, 2016, 2020, 2024.
Fuel
Direct fuel injection time 1 LEGACY_DIRECT_FUEL_INJ_TIME_1Confirmed
- Service 22
DID 1357 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Direct fuel injection time 2 LEGACY_DIRECT_FUEL_INJ_TIME_2Confirmed
- Service 22
DID 1358 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Direct fuel injection time 3 LEGACY_DIRECT_FUEL_INJ_TIME_3Confirmed
- Service 22
DID 1359 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Direct fuel injection time 4 LEGACY_DIRECT_FUEL_INJ_TIME_4Confirmed
- Service 22
DID 135A - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Fuel injection 1 pulse width LEGACY_FUEL_INJ_1_WIDTH
- Service 22
DID 10A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 65.28 ms
- Unit
- ms
In testing for 1996 to 2021, 2023 to 2025. Not supported for 2022.
Fuel injector #2 pulse width LEGACY_FUEL_INJECTOR_2_PULSE_WIDTH
- Service 22
DID 10A4 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 65.28 ms
- Unit
- ms
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Fuel level LEGACY_FLI
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 002F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011, 2016 to 2017, 2022, 2024.
Fuel pump duty LEGACY_FUEL_PUMP_DUTYConfirmed
- Service 22
DID 10B3 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Fuel rail pressure LEGACY_FRP
- Service 22
DID 0023 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2016 to 2017. Supported for 2011, 2020, 2022, 2024.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2016 to 2017. Supported for 2011, 2020, 2022, 2024.
Fuel tank air pressure LEGACY_FUEL_TANK_AIR_PRESSUREConfirmed
- Service 22
DID 10E6 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655
- Unit
- Raw value
0x0000 = 0 → = 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016 to 2017, 2022. Supported for 2011, 2020, 2024.
Split ratio of fuel injection 1 LEGACY_SPLIT_RAT_FUEL_INJ_1Confirmed
- Service 22
DID 1352 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x58 = 88 → = 34.509804 %
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Split ratio of fuel injection 2 LEGACY_SPLIT_RAT_FUEL_INJ_2Confirmed
- Service 22
DID 1353 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Split ratio of fuel injection 3 LEGACY_SPLIT_RAT_FUEL_INJ_3Confirmed
- Service 22
DID 1354 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Split ratio of fuel injection 4 LEGACY_SPLIT_RAT_FUEL_INJ_4Confirmed
- Service 22
DID 1355 - Module
7E0 → 7E8 - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Sub fuel pump relay switch LEGACY_SUB_FUEL_PUMP_RELAY_SWITCH
- Service 22
DID 1251 - Module
7A2 → 7AA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Lights
Stop light switch LEGACY_STOP_LIGHT_SWITCHConfirmed
- Service 22
DID 1230 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Movement
Drive motor speed LEGACY_DRIVEMOTOR_SPEED
- Service 22
DID 1058 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Drive motor speed target LEGACY_DRIVEMOTOR_SPEED_TARGET
- Service 22
DID 1059 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Front left wheel speed LEGACY_TIRE_FL_SPD
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
In testing for 1996 to 2025.
Front right wheel speed LEGACY_TIRE_FR_SPD
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
In testing for 1996 to 2025.
Front wheel speed LEGACY_FRONT_WHEEL_SPEEDConfirmed
- Service 22
DID 1147 - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Main accelerator sensor LEGACY_MAIN_ACCEL_SENSConfirmed
- Service 22
DID 1279 - Module
7E0 → 7E8 - Every
250 ms - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5.1 V
- Unit
- V
0x21 = 33 → = 0.66 V
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Primary pulley speed LEGACY_PRIMARY_PULLEY_SPEEDConfirmed
- Service 22
DID 1146 - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Rear left wheel speed LEGACY_TIRE_RL_SPD
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
In testing for 1996 to 2025.
Rear right wheel speed LEGACY_TIRE_RR_SPD
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
In testing for 1996 to 2025.
Secondary pulley speed LEGACY_SECONDARY_PULLEY_SPEEDConfirmed
- Service 22
DID 1138 - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Sub accelerator sensor LEGACY_SUB_ACCEL_SENSConfirmed
- Service 22
DID 1278 - Module
7E0 → 7E8 - Every
250 ms - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5.1 V
- Unit
- V
0x21 = 33 → = 0.66 V
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Target engine speed LEGACY_TARGET_ENGINE_SPEEDConfirmed
- Service 22
DID 1121 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
0x08FC = 2300 → = 575 rpm
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Transmission turbine speed LEGACY_TRANS_TURBINE_SPDConfirmed
- Service 22
DID 1298 - Module
7E0 → 7E8 - Every
250 ms - Testing for 1996 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x04EF = 1263 → 1,263 rpm
Confirmed for 2022. In testing for 1996 to 2021, 2023 to 2025.
Turbine revolution speed LEGACY_TURBINE_REVOLUTION
- Service 22
DID 11CB - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2097120 rpm
- Unit
- rpm
In testing for 1996 to 2021, 2023 to 2025. Not supported for 2022.
Turbine speed LEGACY_TURBINE_SPEEDConfirmed
- Service 22
DID 10CB - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
0x00 = 0 → = 0 rpm
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2011, 2016 to 2017, 2022, 2024. Supported for 2020.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2011, 2016 to 2017, 2022. Supported for 2020, 2024.
Orientation
Lateral g LEGACY_LAT_G
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.5 to 2.5 g
- Unit
- g
In testing for 1996 to 2025.
Longitudinal g LEGACY_LNG_G
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.5 to 2.5 g
- Unit
- g
In testing for 1996 to 2025.
Yaw rate LEGACY_YAW_RATE
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 °
- Unit
- °
In testing for 1996 to 2025.
Tires
Front left tire pressure LEGACY_TP_FLConfirmed
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 1022 - Module
753 → 75B - Every
15 s - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 psi
- Unit
- psi
0x96 = 150 → = 30 psi
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Front left wheel speed LEGACY_FL_VSSConfirmed
- Service 22
DID 1025 - Module
7B0 → 7B8 - Every
250 ms - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3686 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Front right tire pressure LEGACY_TP_FRConfirmed
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 1022 - Module
753 → 75B - Every
15 s - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 psi
- Unit
- psi
0x93 = 147 → = 29.4 psi
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Front right wheel speed LEGACY_FR_VSSConfirmed
- Service 22
DID 1024 - Module
7B0 → 7B8 - Every
250 ms - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3686 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Rear left tire pressure LEGACY_TP_RLConfirmed
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 1022 - Module
753 → 75B - Every
15 s - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 psi
- Unit
- psi
0x99 = 153 → = 30.6 psi
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Rear left wheel speed LEGACY_RL_VSSConfirmed
- Service 22
DID 1027 - Module
7B0 → 7B8 - Every
250 ms - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3686 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Rear right tire pressure LEGACY_TP_RRConfirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 1022 - Module
753 → 75B - Every
15 s - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 psi
- Unit
- psi
0x90 = 144 → = 28.8 psi
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Rear right wheel speed LEGACY_RR_VSSConfirmed
- Service 22
DID 1026 - Module
7B0 → 7B8 - Every
250 ms - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3686 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Tire 1 id LEGACY_TID1Confirmed
- Service 22
DID 1028 - Module
753 → 75B - Every
86400 s - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215
- Unit
- Number
0x01616C = 90476 → 90,476
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Tire 2 id LEGACY_TID2Confirmed
- Service 22
DID 1028 - Module
753 → 75B - Every
86400 s - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 24 to 47 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215
- Unit
- Number
0x870161 = 8847713 → 8,847,713
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Tire 3 id LEGACY_TID3Confirmed
- Service 22
DID 1028 - Module
753 → 75B - Every
86400 s - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 48 to 71 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215
- Unit
- Number
0x6B1E01 = 7020033 → 7,020,033
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Tire 4 id LEGACY_TID4Confirmed
- Service 22
DID 1028 - Module
753 → 75B - Every
86400 s - Testing for 1996 to 2015, 2018 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 72 to 95 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215
- Unit
- Number
0x616D6A = 6385002 → 6,385,002
Confirmed for 2016 to 2017, 2022, 2024. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011.
Transmission
Actual gear ratio LEGACY_ACTUAL_GEAR_RATIOConfirmed
- Service 22
DID 113E - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
0x0064 = 100 → = 0.390631
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
All-wheel drive transfer clutch duty LEGACY_AWD_TRANSFER_DUTY
- Service 22
DID 1065 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 1996 to 2025.
Target gear ratio LEGACY_TARGET_GEAR_RATIOConfirmed
- Service 22
DID 113D - Module
7A3 → 7AB - Every
1 s - Testing for 1996 to 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 0.9961
- Unit
- Number
0x00 = 0 → = 0
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022.
Torque converter lock-up duty LEGACY_CVT_LOCKUP_DUTY
- Service 22
DID 1045 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 1996 to 2025.
Turbine speed LEGACY_CVT_TURBINE_RPM
- Service 22
DID 1067 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 1996 to 2025.
Trips
Estimated distance to oil change LEGACY_ESTIMATED_DIST_OIL
- Service 22
DID 1155 - Module
7A2 → 7AA - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 km
- Unit
- km
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Not supported for 2004, 2011, 2016, 2022, 2024.
Estimated distance to oil change LEGACY_ESTIMATED_DIST_OIL_CHANGE
- Service 22
DID 1155 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 km
- Unit
- km
In testing for 1996 to 2021, 2023 to 2025. Not supported for 2022.
Odometer LEGACY_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 10E5 - Module
7E0 → 7E8 - Every
15 s - Testing for 1996 to 2015, 2018 to 2021, 2023 to 2025
Example reply from a 2022 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070 km
- Unit
- km
0x8807 = 34823 → = 69,646 km
Confirmed for 2016 to 2017, 2022. In testing for 1996 to 2003, 2006 to 2010, 2012 to 2015, 2018 to 2021, 2023, 2025. Not supported for 2004 to 2005, 2011, 2024.
Odometer LEGACY_ODO_7A2_10A5
Pelican can show this parameter as the odometer.
- Service 22
DID 10A5 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023 to 2025
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070 km
- Unit
- km
In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016, 2024.
Odometer LEGACY_ODO_7A2_10E5Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 10E5 - Module
7A2 → 7AA - Every
1 s - Testing for 1996 to 2021, 2023, 2025
Example reply from a 2024 Subaru Legacy.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070 km
- Unit
- km
0x2275 = 8821 → = 17,642 km
Confirmed for 2024. In testing for 1996 to 2003, 2005 to 2010, 2012 to 2015, 2017 to 2021, 2023, 2025. Supported for 2022. Not supported for 2004, 2011, 2016.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2022, 2024.
Previous trip distance LEGACY_PREV_TRIP_DST
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 km
- Unit
- km
In testing for 1996 to 2025.