smart forfour

Parameters

The smart forfour has 402 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V system voltage, hd SMART_EQA_AUX_V_HD

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 0201
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 100 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V system voltage, hd SMART_EQA_AUX_V_HD

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 0201
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 100 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Auxiliary battery voltage SMART_EQA_AUX_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2005
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25.9255
Range
0 to 25.9 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Battery age condition SMART_ED_BAT_AGE

  • Service 22DID 6308
  • Module7E5 → 7ED
  • Every600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

Battery heater on SMART_ED_HEATER_ON

  • Service 22DID D302
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2004 to 2006, 2014 to 2021.

Battery module 1 temperature SMART_ED_MOD_T1

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Battery module 2 temperature SMART_ED_MOD_T2

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Battery module 3 temperature SMART_ED_MOD_T3

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Battery module 4 temperature SMART_ED_MOD_T4

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Battery module 5 temperature SMART_ED_MOD_T5

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Battery module 6 temperature SMART_ED_MOD_T6

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Battery module 7 temperature SMART_ED_MOD_T7

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Battery module 8 temperature SMART_ED_MOD_T8

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Battery module 9 temperature SMART_ED_MOD_T9

  • Service 22DID 0202
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Battery operating mode SMART_EV_MODE

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Capacity loss SMART_CAP_LOSS

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

Cell capacity, average SMART_ED_CAP_AS_AVG

  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
val3600
Range
0 to 18.2041 Ah
Unit
Ah

In testing for 2004 to 2006, 2014 to 2021.

Cell capacity, maximum SMART_ED_CAP_AS_MAX

  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val3600
Range
0 to 18.2041 Ah
Unit
Ah

In testing for 2004 to 2006, 2014 to 2021.

Cell capacity, minimum SMART_ED_CAP_AS_MIN

  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
val3600
Range
0 to 18.2041 Ah
Unit
Ah

In testing for 2004 to 2006, 2014 to 2021.

Cell voltage reference, average SMART_ED_ADC_V_AVG

  • Service 22DID 0207
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2004 to 2006, 2014 to 2021.

Cell voltage reference, maximum SMART_ED_ADC_V_MAX

  • Service 22DID 0207
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val+1500
Range
1500 to 67035 mV
Unit
mV

In testing for 2004 to 2006, 2014 to 2021.

Cell voltage reference, minimum SMART_ED_ADC_V_MIN

  • Service 22DID 0207
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val+1500
Range
1500 to 67035 mV
Unit
mV

In testing for 2004 to 2006, 2014 to 2021.

Charger 12V output voltage SMART_ED_OBL_LV

  • Service 22DID 0226
  • Module61A → 483
  • Every10 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Charger cooling plate temperature SMART_ED_OBL_PLATE_T

  • Service 22DID 0223
  • Module61A → 483
  • Every60 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Charger current set point SMART_ED_OBL_A_SET

  • Service 22DID 022A
  • Module61A → 483
  • Every60 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Charger HV output current SMART_ED_OBL_HV_A

  • Service 22DID 0225
  • Module61A → 483
  • Every10 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val10
Range
0 to 204.7 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Charger HV output voltage SMART_ED_OBL_HV

  • Service 22DID 0226
  • Module61A → 483
  • Every10 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val10
Range
0 to 819 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Charger mains current SMART_ED_OBL_MAINS_A

  • Service 22DID 0225
  • Module61A → 483
  • Every10 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 204.7 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Charger mains current, phase 1 SMART_OBL_A1

  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 5990.4 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Charger mains current, phase 2 SMART_OBL_A2

  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 5990.4 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Charger mains voltage SMART_ED_OBL_MAINS_V

  • Service 22DID 0226
  • Module61A → 483
  • Every10 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val10
Range
0 to 819 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Charger mains voltage SMART_OBL_V

  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 5990.4 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Charger power 1 SMART_OBL_P1

  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val2000
Range
0 to 29.952 kW
Unit
kW

In testing for 2004 to 2006, 2014 to 2021.

Charger power 2 SMART_OBL_P2

  • Service 22DID 7303
  • Module792 → 793
  • Every10 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val2000
Range
0 to 29.952 kW
Unit
kW

In testing for 2004 to 2006, 2014 to 2021.

Charger temperature SMART_ED_OBL_T

  • Service 22DID 0223
  • Module61A → 483
  • Every60 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Charging cable current code SMART_ED_OBL_CABLE_A

  • Service 22DID 0225
  • Module61A → 483
  • Every10 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Charging plug detected SMART_PLUG

Pelican can show this parameter as the plug state.

  • Service 22DID 339D
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2004 to 2006, 2014 to 2021.

Charging socket temperature SMART_ED_OBL_SOCKET_T

  • Service 22DID 0223
  • Module61A → 483
  • Every60 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Coolant pump voltage, M13/5 SMART_CLT_PMP_V_M13_5

  • Service 22DID 5504
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.87 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Coolant pump voltage, M43/1 SMART_CLT_PMP_V_M43_1

  • Service 22DID 5506
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.87 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

DC converter requested voltage SMART_CNVRTR_REQ_V

  • Service 22DID 6071
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25010000
Range
0 to 1638.375 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

DC converter requested voltage SMART_EQA_CNVRTR_REQ_V

  • Service 22DID 6071
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25010000
Range
0 to 100 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Estimated capacity SMART_CAP_EST

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val360
Range
0 to 182.0416 Ah
Unit
Ah

In testing for 2004 to 2006, 2014 to 2021.

High voltage PTC heater voltage, N33/5 SMART_HIGH_V_PTC_HEATER_V_5

  • Service 22DID 550A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

High voltage system voltage at power machine 1 unit, N129/1 SMART_HIGH_V_SYSTEM_V_1_1

  • Service 22DID 012F
  • Module662 → 5E2
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Highest cell voltage SMART_CELL_V_MAX

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

HV battery amperage SMART_EQA_HV_A

  • Service 22DID 6053
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
0 to 100 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

HV battery amperage SMART_HV_A_V2

  • Service 22DID 6053
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

HV battery available energy SMART_HV_E

  • Service 22DID 320C
  • Module7E4 → 7EC
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327.675 kWh
Unit
kWh

In testing for 2004 to 2006, 2014 to 2021.

HV battery coolant temperature SMART_EQA_HV_COOLANT_T

  • Service 22DID 2526
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×125010000
Range
0 to 100 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

HV battery current SMART_ED_HV_A

  • Service 22DID 0203
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.9687 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

HV battery current SMART_HV_A

Pelican can show this parameter as the traction battery current.

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val×-132
Range
-1023.9687 to 1024 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

HV battery open-circuit voltage SMART_OCV

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

HV battery state of charge SMART_EQA_HV_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 6050
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

HV battery temperature SMART_ED_HV_T

  • Service 22DID 0201
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

HV battery temperature, average SMART_HV_T_AVG

  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

HV battery temperature, maximum SMART_HV_T_MAX

  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

HV battery temperature, minimum SMART_HV_T_MIN

  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

HV battery voltage SMART_ED_HV_V

  • Service 22DID 0204
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

HV battery voltage SMART_EQA_HV_V

  • Service 22DID 6075
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×251000
Range
0 to 100 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

HV battery voltage SMART_HV_V

Pelican can show this parameter as the traction battery voltage.

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

HV battery voltage SMART_HV_V_V2

  • Service 22DID 6075
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×251000
Range
0 to 1638.375 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

HV contactor cycles remaining SMART_ED_CONT_LEFT

  • Service 22DID 030B
  • Module7E7 → 7EF
  • Every600 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

HV contactor cycles remaining SMART_HV_CONT_LEFT

  • Service 21PID 02
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

HV contactor cycles, maximum SMART_ED_CONT_MAX

  • Service 22DID 030C
  • Module7E7 → 7EF
  • Every600 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

HV contactor cycles, maximum SMART_HV_CONT_MAX

  • Service 21PID 02
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

HV contactor state SMART_ED_CONTACTOR

  • Service 22DID D000
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

HV contactor state SMART_HV_CONTACTOR

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

HV DC fault code SMART_ED_DC_FAULT

  • Service 22DID 0209
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

HV isolation resistance SMART_ED_ISO

  • Service 22DID 0209
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65534 kΩ
Unit
kΩ

In testing for 2004 to 2006, 2014 to 2021.

HV plug interlock closed SMART_HV_INTERLOCK_PLUG

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2004 to 2006, 2014 to 2021.

Initial capacity SMART_CAP_INIT

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val360
Range
0 to 182.0416 Ah
Unit
Ah

In testing for 2004 to 2006, 2014 to 2021.

Leakage current, 10 kilohertz SMART_LEAK_HF10

  • Service 22DID 5066
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.768 to 32.7669
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Leakage DC current SMART_LEAK_DC

  • Service 22DID 5065
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.768 to 32.7669
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Leakage diagnostic code SMART_LEAK_DIAG

  • Service 22DID 5064
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Leakage high-frequency current SMART_LEAK_HF

  • Service 22DID 5067
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.768 to 32.7669
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Leakage low-frequency current SMART_LEAK_LF

  • Service 22DID 5068
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.768 to 32.7669
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Lowest cell voltage SMART_CELL_V_MIN

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Mains active power SMART_MAINS_P

  • Service 22DID 504A
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−20
Range
-20 to 45.5349 kW
Unit
kW

In testing for 2004 to 2006, 2014 to 2021.

Mains current limit SMART_MAINS_A_LIMIT

  • Service 22DID 5070
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.768 to 32.7669
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Mains current, phase 2 SMART_MAINS_A_2

  • Service 22DID 503A
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−200
Range
-200 to 3895.9375 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Mains current, phase 3 SMART_MAINS_A_3

  • Service 22DID 503B
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−200
Range
-200 to 3895.9375 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Mains frequency SMART_MAINS_HZ

  • Service 22DID 5049
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128+10
Range
10 to 521.9921 Hz
Unit
Hz

In testing for 2004 to 2006, 2014 to 2021.

Mains ground resistance SMART_MAINS_GND_R

  • Service 22DID 5062
  • Module792 → 793
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000−32.768
Range
-32.768 to 32.7669
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Mains voltage, phases 1-2 SMART_MAINS_V_12

  • Service 22DID 503F
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Mains voltage, phases 2-3 SMART_MAINS_V_23

  • Service 22DID 5041
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Mains voltage, phases 3-1 SMART_MAINS_V_31

  • Service 22DID 5042
  • Module792 → 793
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Open-circuit voltage state SMART_OCV_STATE

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 4
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Real state of charge, maximum SMART_SOC_REAL_MAX

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

Real state of charge, minimum SMART_SOC_REAL_MIN

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

Service interlock closed SMART_HV_INTERLOCK_SVC

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2004 to 2006, 2014 to 2021.

State of charge SMART_SOC

Pelican can show this parameter as the state of charge.

  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

State of charge recalibration state SMART_SOC_RECAL

  • Service 21PID 25
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

State of charge, displayed SMART_SOC_DISPLAY

  • Service 21PID 25
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

State of health SMART_SOH

Pelican can show this parameter as the state of health.

  • Service 21PID 61
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

State of health, raw SMART_ED_SOH

  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Sum of cell voltages SMART_HV_CELL_SUM_V

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Time with HV off SMART_ED_HV_OFF_TIME

  • Service 22DID 0310
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 s
Unit
s

In testing for 2004 to 2006, 2014 to 2021.

Usable capacity, full SMART_CAP_FULL

  • Service 21PID 61
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val360
Range
-91.0222 to 91.0194 Ah
Unit
Ah

In testing for 2004 to 2006, 2014 to 2021.

Cells

Cell 1 voltage SMART_CELL_V1

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 1 voltage SMART_ED_CELL_V1

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 2 voltage SMART_CELL_V2

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 2 voltage SMART_ED_CELL_V2

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 3 voltage SMART_CELL_V3

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 3 voltage SMART_ED_CELL_V3

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 4 voltage SMART_CELL_V4

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 4 voltage SMART_ED_CELL_V4

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 5 voltage SMART_CELL_V5

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 5 voltage SMART_ED_CELL_V5

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 6 voltage SMART_CELL_V6

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 6 voltage SMART_ED_CELL_V6

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 7 voltage SMART_CELL_V7

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 7 voltage SMART_ED_CELL_V7

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 8 voltage SMART_CELL_V8

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 8 voltage SMART_ED_CELL_V8

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 9 voltage SMART_CELL_V9

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 9 voltage SMART_ED_CELL_V9

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 10 voltage SMART_CELL_V10

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 10 voltage SMART_ED_CELL_V10

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 11 voltage SMART_CELL_V11

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 11 voltage SMART_ED_CELL_V11

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 12 voltage SMART_CELL_V12

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 12 voltage SMART_ED_CELL_V12

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 13 voltage SMART_CELL_V13

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 13 voltage SMART_ED_CELL_V13

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 14 voltage SMART_CELL_V14

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 14 voltage SMART_ED_CELL_V14

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 15 voltage SMART_CELL_V15

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 15 voltage SMART_ED_CELL_V15

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 16 voltage SMART_CELL_V16

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 16 voltage SMART_ED_CELL_V16

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 17 voltage SMART_CELL_V17

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 17 voltage SMART_ED_CELL_V17

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 18 voltage SMART_CELL_V18

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 18 voltage SMART_ED_CELL_V18

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 19 voltage SMART_CELL_V19

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 19 voltage SMART_ED_CELL_V19

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 20 voltage SMART_CELL_V20

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 20 voltage SMART_ED_CELL_V20

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 21 voltage SMART_CELL_V21

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 21 voltage SMART_ED_CELL_V21

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 22 voltage SMART_CELL_V22

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 22 voltage SMART_ED_CELL_V22

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 23 voltage SMART_CELL_V23

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 23 voltage SMART_ED_CELL_V23

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 24 voltage SMART_CELL_V24

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 24 voltage SMART_ED_CELL_V24

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 25 voltage SMART_CELL_V25

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 25 voltage SMART_ED_CELL_V25

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 26 voltage SMART_CELL_V26

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 26 voltage SMART_ED_CELL_V26

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 27 voltage SMART_CELL_V27

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 27 voltage SMART_ED_CELL_V27

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 28 voltage SMART_CELL_V28

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 28 voltage SMART_ED_CELL_V28

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 29 voltage SMART_CELL_V29

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 29 voltage SMART_ED_CELL_V29

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 30 voltage SMART_CELL_V30

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 30 voltage SMART_ED_CELL_V30

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 31 voltage SMART_CELL_V31

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 31 voltage SMART_ED_CELL_V31

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 32 voltage SMART_CELL_V32

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 32 voltage SMART_ED_CELL_V32

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 33 voltage SMART_CELL_V33

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 33 voltage SMART_ED_CELL_V33

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 34 voltage SMART_CELL_V34

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 34 voltage SMART_ED_CELL_V34

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 35 voltage SMART_CELL_V35

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 35 voltage SMART_ED_CELL_V35

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 36 voltage SMART_CELL_V36

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 36 voltage SMART_ED_CELL_V36

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 37 voltage SMART_CELL_V37

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 37 voltage SMART_ED_CELL_V37

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 38 voltage SMART_CELL_V38

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 38 voltage SMART_ED_CELL_V38

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 39 voltage SMART_CELL_V39

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 39 voltage SMART_ED_CELL_V39

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 40 voltage SMART_CELL_V40

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 40 voltage SMART_ED_CELL_V40

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 41 voltage SMART_CELL_V41

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 41 voltage SMART_ED_CELL_V41

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 42 voltage SMART_CELL_V42

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 42 voltage SMART_ED_CELL_V42

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 43 voltage SMART_CELL_V43

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 43 voltage SMART_ED_CELL_V43

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 44 voltage SMART_CELL_V44

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 44 voltage SMART_ED_CELL_V44

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 45 voltage SMART_CELL_V45

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 45 voltage SMART_ED_CELL_V45

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 46 voltage SMART_CELL_V46

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 46 voltage SMART_ED_CELL_V46

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 47 voltage SMART_CELL_V47

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 47 voltage SMART_ED_CELL_V47

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 48 voltage SMART_CELL_V48

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 48 voltage SMART_ED_CELL_V48

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 49 voltage SMART_CELL_V49

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 49 voltage SMART_ED_CELL_V49

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 50 voltage SMART_CELL_V50

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 50 voltage SMART_ED_CELL_V50

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 51 voltage SMART_CELL_V51

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 51 voltage SMART_ED_CELL_V51

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 52 voltage SMART_CELL_V52

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 52 voltage SMART_ED_CELL_V52

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 53 voltage SMART_CELL_V53

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 53 voltage SMART_ED_CELL_V53

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 54 voltage SMART_CELL_V54

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 54 voltage SMART_ED_CELL_V54

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 55 voltage SMART_CELL_V55

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 55 voltage SMART_ED_CELL_V55

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 56 voltage SMART_CELL_V56

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 56 voltage SMART_ED_CELL_V56

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 57 voltage SMART_CELL_V57

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 57 voltage SMART_ED_CELL_V57

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 58 voltage SMART_CELL_V58

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 58 voltage SMART_ED_CELL_V58

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 59 voltage SMART_CELL_V59

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 59 voltage SMART_ED_CELL_V59

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 60 voltage SMART_CELL_V60

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 60 voltage SMART_ED_CELL_V60

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 61 voltage SMART_CELL_V61

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 61 voltage SMART_ED_CELL_V61

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 62 voltage SMART_CELL_V62

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 62 voltage SMART_ED_CELL_V62

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 63 voltage SMART_CELL_V63

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 63 voltage SMART_ED_CELL_V63

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 64 voltage SMART_CELL_V64

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 64 voltage SMART_ED_CELL_V64

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 65 voltage SMART_CELL_V65

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 65 voltage SMART_ED_CELL_V65

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 66 voltage SMART_CELL_V66

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 66 voltage SMART_ED_CELL_V66

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 67 voltage SMART_CELL_V67

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 67 voltage SMART_ED_CELL_V67

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 68 voltage SMART_CELL_V68

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 68 voltage SMART_ED_CELL_V68

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 69 voltage SMART_CELL_V69

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 69 voltage SMART_ED_CELL_V69

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 70 voltage SMART_CELL_V70

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 70 voltage SMART_ED_CELL_V70

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 71 voltage SMART_CELL_V71

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 71 voltage SMART_ED_CELL_V71

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 72 voltage SMART_CELL_V72

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 72 voltage SMART_ED_CELL_V72

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 73 voltage SMART_CELL_V73

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 73 voltage SMART_ED_CELL_V73

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 74 voltage SMART_CELL_V74

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 74 voltage SMART_ED_CELL_V74

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 75 voltage SMART_CELL_V75

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 75 voltage SMART_ED_CELL_V75

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 76 voltage SMART_CELL_V76

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 76 voltage SMART_ED_CELL_V76

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 77 voltage SMART_CELL_V77

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 77 voltage SMART_ED_CELL_V77

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 78 voltage SMART_CELL_V78

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 78 voltage SMART_ED_CELL_V78

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 79 voltage SMART_CELL_V79

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 79 voltage SMART_ED_CELL_V79

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 80 voltage SMART_CELL_V80

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 80 voltage SMART_ED_CELL_V80

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 81 voltage SMART_CELL_V81

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 81 voltage SMART_ED_CELL_V81

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 82 voltage SMART_CELL_V82

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 82 voltage SMART_ED_CELL_V82

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 83 voltage SMART_CELL_V83

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 83 voltage SMART_ED_CELL_V83

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 84 voltage SMART_CELL_V84

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 84 voltage SMART_ED_CELL_V84

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 85 voltage SMART_CELL_V85

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 85 voltage SMART_ED_CELL_V85

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 86 voltage SMART_CELL_V86

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 86 voltage SMART_ED_CELL_V86

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 87 voltage SMART_CELL_V87

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 87 voltage SMART_ED_CELL_V87

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 88 voltage SMART_CELL_V88

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 88 voltage SMART_ED_CELL_V88

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 89 voltage SMART_CELL_V89

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 89 voltage SMART_ED_CELL_V89

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 90 voltage SMART_CELL_V90

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 90 voltage SMART_ED_CELL_V90

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 91 voltage SMART_CELL_V91

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 91 voltage SMART_ED_CELL_V91

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 92 voltage SMART_CELL_V92

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 92 voltage SMART_ED_CELL_V92

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 93 voltage SMART_CELL_V93

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 93 voltage SMART_ED_CELL_V93

  • Service 22DID 0208
  • Module7E7 → 7EF
  • Every60 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 94 voltage SMART_CELL_V94

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 95 voltage SMART_CELL_V95

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Cell 96 voltage SMART_CELL_V96

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Brakes

Vacuum pump pressure 1 SMART_ED_VAC_P1

  • Service 22DID 2041
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Vacuum pump pressure 2 SMART_ED_VAC_P2

  • Service 22DID 2043
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Climate

Cabin blower command SMART_BLOWER

  • Service 22DID 34CB
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 100 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

Outside temperature SMART_AAT

  • Service 22DID 200C
  • Module743 → 763
  • Every20 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Control

Steering wheel angle SMART_STEER_ANGLE

Positive is rotated to the right, negative is rotated to the left.

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2004 to 2006, 2014 to 2021.

Details

Days to next service SMART_SVC_DAYS

  • Service 22DID 0204
  • Module743 → 763
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Distance to next service SMART_SVC_DIST

  • Service 22DID 0203
  • Module743 → 763
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2004 to 2006, 2014 to 2021.

Service level SMART_SVC_LEVEL

  • Service 22DID 0188
  • Module743 → 763
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Doors

Driver door locked SMART_DRIVER_LOCKED

  • Service 21PID 25
  • Module745 → 765
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2004 to 2006, 2014 to 2021.

Drivetrain

Motor speed SMART_MOTOR_RPM

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

In testing for 2004 to 2006, 2014 to 2021.

Electrical

12V supply voltage, battery controller SMART_12V_V_BMS

  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val8
Range
0 to 31.875 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

DC/DC activation request SMART_DCDC_REQ

  • Service 22DID 3022
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

DC/DC load SMART_DCDC_LOAD

  • Service 22DID 3495
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.56
Range
0 to 99.21875 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

DC/DC output current SMART_DCDC_A

  • Service 22DID 3025
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

DC/DC output power SMART_DCDC_P

  • Service 22DID 3494
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 W
Unit
W

In testing for 2004 to 2006, 2014 to 2021.

DC/DC output voltage SMART_DCDC_V

  • Service 22DID 3024
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+4
Range
4 to 29.5 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

DC/DC voltage request SMART_DCDC_V_REQ

  • Service 22DID 3023
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+12
Range
12 to 24.75 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Power distribution 12V voltage SMART_USM_V

  • Service 22DID 3301
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.06+6
Range
6 to 21.2999 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Engine

AC current SMART_AC_CURRENT

  • Service 22DID 0202
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val10−819.2
Range
-819 to 5734 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Boost air temperature SMART_BOOST_AIR_T

  • Service 22DID 0163
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10−273.1
Range
-273 to 6280 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Boost pressure SMART_BOOST_P

  • Service 22DID 0163
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2004 to 2006, 2014 to 2021.

Coolant pump current SMART_ED_PUMP_A

  • Service 22DID 2309
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val5
Range
0 to 51 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Coolant pump speed SMART_ED_PUMP_DUTY

  • Service 22DID D032
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

Coolant pump temperature SMART_ED_PUMP_T

  • Service 22DID 230A
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Coolant pump voltage SMART_ED_PUMP_V

  • Service 22DID 2308
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Coolant temperature SMART_ED_COOLANT_T

  • Service 22DID 2047
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191.875 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Cooling fan speed SMART_ED_FAN_DUTY

  • Service 22DID D041
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

DC/DC module state, boost SMART_DC_DC_MODULE_ST

  • Service 22DID 6074
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Diesel particulate filter differential pressure SMART_DPF_DIFF_P

  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2004 to 2006, 2014 to 2021.

Distance to next service SMART_EQA_SERVICE_DIST

  • Service 22DID 6504
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2004 to 2006, 2014 to 2021.

Electric machine 2 coolant temperature SMART_ELEC_MACHINE_2_ECT

  • Service 22DID 0200
  • Module624 → 5A4
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Electric machine 2 rotor temperature SMART_ELEC_MACHINE_2_ROTOR_T

  • Service 22DID 0200
  • Module624 → 5A4
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Electric machine 2 state, diagnostic SMART_ELEC_MACHINE_2_ST

  • Service 22DID 0206
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Electric machine 2 stator temperature 1 SMART_ELEC_MACHINE_2_T_1

  • Service 22DID 0200
  • Module624 → 5A4
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Electric machine 2 stator temperature 2 SMART_ELEC_MACHINE_2_T_2

  • Service 22DID 0200
  • Module624 → 5A4
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Electric machine 2, actual torque SMART_ELEC_MACHINE_2_ACT

  • Service 22DID 0207
  • Module624 → 5A4
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−500
Range
-500 to 6053 N·m
Unit
N·m

In testing for 2004 to 2006, 2014 to 2021.

Electric machine, N129/1 power level, 0-4 SMART_ELEC_MACHINE_N129_1_0_4

  • Service 22DID 0306
  • Module662 → 5E2
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Electric machine, N129/1 requested power level, 0-4 SMART_ELEC_MACHINE_N129_1_REQ_0_4

  • Service 22DID 0306
  • Module662 → 5E2
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Engine oil temperature SMART_EOT

  • Service 22DID 2095
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2720−54
Range
-54 to 290 °F
Unit
°F

In testing for 2004 to 2006, 2014 to 2021.

Exhaust back pressure SMART_EXH_BACK_P

  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2004 to 2006, 2014 to 2021.

Fan motor duty, M4/7 SMART_FAN_MOTOR_DUTY_M4_7

  • Service 22DID D50A
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

High voltage components, N129/1 locked state SMART_HIGH_V_COMPONENTS_1

  • Service 22DID 012C
  • Module662 → 5E2
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

High voltage PTC heater state, N33/5 SMART_HIGH_V_PTC_HEATER_ST_5

  • Service 22DID 550C
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2004 to 2006, 2014 to 2021.

Master break cylinder pressure SMART_MASTER_BREAK_CYLINDER_PRESSURE

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val×15310000
Range
-500 to 500 bar
Unit
bar

In testing for 2004 to 2006, 2014 to 2021.

Parking lock adaptation state SMART_PARKING_LOCK_ADPT_ST

  • Service 22DID 0301
  • Module662 → 5E2
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Parking lock state SMART_PARKING_LOCK_ST

  • Service 22DID 0302
  • Module662 → 5E2
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Phase U current SMART_PHASE_U_CURRENT

  • Service 22DID 0202
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val10−819.2
Range
-819 to 5734 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Phase V current SMART_PHASE_V_CURRENT

  • Service 22DID 0202
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val10−819.2
Range
-819 to 5734 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Phase W current SMART_PHASE_W_CURRENT

  • Service 22DID 0202
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val10−819.2
Range
-819 to 5734 A
Unit
A

In testing for 2004 to 2006, 2014 to 2021.

Power electric unit temperature sensor, B11/5 SMART_POWER_ELEC_UNIT_T_5

  • Service 22DID 2525
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Power machine 1 stator temperature SMART_POWER_MACHINE_1_T

  • Service 22DID 0200
  • Module662 → 5E2
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val2−40
Range
-40 to 32727 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Power machine 1, actual torque SMART_POWER_MACHINE_1_ACT

  • Service 22DID 0200
  • Module662 → 5E2
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−500
Range
-500 to 6053 N·m
Unit
N·m

In testing for 2004 to 2006, 2014 to 2021.

Power machine 1, maximum available torque SMART_POWER_MACHINE_1_MAX

  • Service 22DID 0200
  • Module662 → 5E2
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10−500
Range
-500 to 6053 N·m
Unit
N·m

In testing for 2004 to 2006, 2014 to 2021.

Radiator grill, M2/39 position SMART_RADIATOR_GRILL_M2_39_POS

  • Service 22DID 550F
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2004 to 2006, 2014 to 2021.

Radiator grill, M2/39 status, closing SMART_RADIATOR_GRILL_M2_39

  • Service 22DID 5510
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Radiator temperature SMART_RADIATOR_T

  • Service 22DID 2017
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2732+32
Range
0 to 55327 °F
Unit
°F

In testing for 2004 to 2006, 2014 to 2021.

Remaining operating time SMART_REMAINING_OP_TIME

  • Service 22DID 6503
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−2048
Range
-2048 to 63487
Unit
Raw value

In testing for 2004 to 2006, 2014 to 2021.

Terminal 15 status SMART_KLEMME_15_STAT

  • Service 22DID 3008
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2004 to 2006, 2014 to 2021.

Terminal 30C state SMART_KLEMME_30C_ST

  • Service 22DID 0203
  • Module662 → 5E2
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Terminal 50 status SMART_KLEMME_50_STAT

  • Service 22DID 3505
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2004 to 2006, 2014 to 2021.

Terminal 87 feedback SMART_KLEMME_87_FEEDBACK

  • Service 22DID 2006
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000
Range
0 to 1279 V
Unit
V

In testing for 2004 to 2006, 2014 to 2021.

Terminal 87 status SMART_KLEMME_87_STAT

  • Service 22DID D027
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2004 to 2006, 2014 to 2021.

Vacuum break pressure SMART_VACUUM_BREAK_PRESSURE

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 bar
Unit
bar

In testing for 2004 to 2006, 2014 to 2021.

Fuel

Fuel rail pressure SMART_FUEL_RAIL_P

  • Service 22DID 2071
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.4998701
Range
0 to 32758 kPa
Unit
kPa

In testing for 2004 to 2006, 2014 to 2021.

Fuel tank level SMART_FUEL_TANK_LEVEL

  • Service 22DID 2030
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.099934824
Range
0 to 6549 L
Unit
L

In testing for 2004 to 2006, 2014 to 2021.

Fuel temperature SMART_FUEL_T

  • Service 22DID 016F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Movement

Electric machine 1 rpm SMART_ELEC_MACHINE_1_RPM

  • Service 22DID 0205
  • Module624 → 5A4
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2004 to 2006, 2014 to 2021.

Electric machine 2 rpm SMART_ELEC_MACHINE_2_RPM

  • Service 22DID 0205
  • Module624 → 5A4
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2004 to 2006, 2014 to 2021.

Front left wheel speed SMART_FL_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×562.510000
Range
0 to 1000 km/h
Unit
km/h

In testing for 2004 to 2006, 2014 to 2021.

Front left wheel speed SMART_TIRE_FL_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 1000 km/h
Unit
km/h

In testing for 2004 to 2006, 2014 to 2021.

Front right wheel speed SMART_FR_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×562.510000
Range
0 to 100 km/h
Unit
km/h

In testing for 2004 to 2006, 2014 to 2021.

Front right wheel speed SMART_TIRE_FR_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 1000 km/h
Unit
km/h

In testing for 2004 to 2006, 2014 to 2021.

Rear left wheel speed SMART_RL_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×562.510000
Range
0 to 100 km/h
Unit
km/h

In testing for 2004 to 2006, 2014 to 2021.

Rear left wheel speed SMART_TIRE_RL_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 1000 km/h
Unit
km/h

In testing for 2004 to 2006, 2014 to 2021.

Rear right wheel speed SMART_RR_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×562.510000
Range
0 to 100 km/h
Unit
km/h

In testing for 2004 to 2006, 2014 to 2021.

Rear right wheel speed SMART_TIRE_RR_VSS

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 1000 km/h
Unit
km/h

In testing for 2004 to 2006, 2014 to 2021.

Orientation

Lateral acceleration SMART_LAT_ACC

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val×15.6251000
Range
-512 to 511 g
Unit
g

In testing for 2004 to 2006, 2014 to 2021.

Lateral acceleration SMART_LAT_G

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val627.6
Range
-52.21 to 52.21 g
Unit
g

In testing for 2004 to 2006, 2014 to 2021.

Longitudinal acceleration SMART_LNG_G

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val192747
Range
-0.17 to 0.17 g
Unit
g

In testing for 2004 to 2006, 2014 to 2021.

Longitudinal acceleration SMART_LON_ACC

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val×0.051000
Range
-1.63 to 1.63 g
Unit
g

In testing for 2004 to 2006, 2014 to 2021.

Master break cylinder pressure SMART_MCYL_BREAK

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val65.35883831
Range
-501.34 to 501.34 bar
Unit
bar

In testing for 2004 to 2006, 2014 to 2021.

Vaccuum cylinder pressure SMART_VACC_BREAK

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32 to 32 bar
Unit
bar

In testing for 2004 to 2006, 2014 to 2021.

Yaw rate SMART_YAW_RATE

The angular velocity of the car around its vertical axis. Indicates how quickly the car is rotating to its left or right.

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val×232767
Range
-2 to 2 rad
Unit
rad

In testing for 2004 to 2006, 2014 to 2021.

Stats

Battery heater operating time SMART_ED_HEATER_HOURS

  • Service 22DID 6321
  • Module7E5 → 7ED
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2004 to 2006, 2014 to 2021.

Coolant pump operating time SMART_ED_PUMP_HOURS

  • Service 22DID 6309
  • Module7E5 → 7ED
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2004 to 2006, 2014 to 2021.

Cooling fan operating time SMART_ED_FAN_HOURS

  • Service 22DID 630A
  • Module7E5 → 7ED
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2004 to 2006, 2014 to 2021.

Tires

Tire sensor 1 battery low SMART_TPMS_LOWBAT_1

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 1 missing SMART_TPMS_MISSING_1

  • Service 21PID 79
  • Module745 → 765
  • Every60 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 1 pressure SMART_TP_1

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×0.75
Range
0 to 49151.25 kPa
Unit
kPa

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 1 temperature SMART_TT_1

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val−30
Range
-30 to 225 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 2 battery low SMART_TPMS_LOWBAT_2

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bit 174 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 2 missing SMART_TPMS_MISSING_2

  • Service 21PID 79
  • Module745 → 765
  • Every60 s
  • Testing

Bit 206 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 2 pressure SMART_TP_2

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×0.75
Range
0 to 49151.25 kPa
Unit
kPa

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 2 temperature SMART_TT_2

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val−30
Range
-30 to 225 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 3 battery low SMART_TPMS_LOWBAT_3

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bit 173 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 3 missing SMART_TPMS_MISSING_3

  • Service 21PID 79
  • Module745 → 765
  • Every60 s
  • Testing

Bit 205 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 3 pressure SMART_TP_3

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val×0.75
Range
0 to 49151.25 kPa
Unit
kPa

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 3 temperature SMART_TT_3

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val−30
Range
-30 to 225 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 4 battery low SMART_TPMS_LOWBAT_4

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bit 172 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 4 missing SMART_TPMS_MISSING_4

  • Service 21PID 79
  • Module745 → 765
  • Every60 s
  • Testing

Bit 204 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 4 pressure SMART_TP_4

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val×0.75
Range
0 to 49151.25 kPa
Unit
kPa

In testing for 2004 to 2006, 2014 to 2021.

Tire sensor 4 temperature SMART_TT_4

  • Service 21PID 74
  • Module745 → 765
  • Every60 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val−30
Range
-30 to 225 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Transmission

Current gear SMART_CURRENT_GEAR

  • Service 21PID 30
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2004 to 2006, 2014 to 2021.

Torque converter slip SMART_TQ_CONV_SLIP

  • Service 21PID 30
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 rpm
Unit
rpm

In testing for 2004 to 2006, 2014 to 2021.

Transmission fluid temperature, variant 1 SMART_ATF_T_VAR_1

  • Service 21PID 30
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×95−58
Range
-58 to 401 °F
Unit
°F

In testing for 2004 to 2006, 2014 to 2021.

Transmission fluid temperature, variant 2 SMART_ATF_T_VAR_2

  • Service 22DID 0230
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×95−58
Range
-58 to 401 °F
Unit
°F

In testing for 2004 to 2006, 2014 to 2021.

Transmission fluid temperature, variant 3 SMART_ATF_T_VAR_3

  • Service 21PID 34
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Transmission fluid temperature, variant 4 SMART_ATF_T_VAR_4

  • Service 22DID 0234
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2004 to 2006, 2014 to 2021.

Trips

Distance at trip start SMART_TRIP_START_DIST

  • Service 22DID 01A0
  • Module743 → 763
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2004 to 2006, 2014 to 2021.

Distance, battery controller SMART_BMS_ODO

  • Service 21PID 61
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2004 to 2006, 2014 to 2021.

HV battery remaining distance SMART_EQA_HV_RANGE

Pelican can show this parameter as the electric range.

  • Service 22DID 6502
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 km
Unit
km

In testing for 2004 to 2006, 2014 to 2021.

Odometer SMART_ODO

  • Service 22DID 016B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070 km
Unit
km

In testing for 2004 to 2006, 2014 to 2021.

Time at trip start SMART_TRIP_START_TIME

  • Service 22DID 01A2
  • Module743 → 763
  • Every60 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 s
Unit
s

In testing for 2004 to 2006, 2014 to 2021.

Trip time SMART_TRIP_TIME

  • Service 22DID 2104
  • Module743 → 763
  • Every60 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 s
Unit
s

In testing for 2004 to 2006, 2014 to 2021.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.