Parameters
The Seat Tarraco has 667 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery capacity TARRACO_12V_BAT_CAP
- Service 22
DID 2A06 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2018 to 2026.
Accelerator pedal, sensor 1 voltage TARRACO_ACCEL_PEDAL_SENS_1_V
- Service 22
DID 102A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2018 to 2026.
Accelerator pedal, sensor 2 voltage TARRACO_ACCEL_PEDAL_SENS_2_V
- Service 22
DID 102B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2018 to 2026.
Battery charge level TARRACO_BAT_SOCConfirmed
- Service 22
DID 2A0C - Module
710 → 77A - Every
10 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x43 = 67 → 67 %
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Battery current TARRACO_BAT_IConfirmed
- Service 22
DID 2A09 - Module
710 → 77A - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483.648 to 2147483 A
- Unit
- A
0x00000000 = 0 → = 0 A
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Battery internal resistance TARRACO_BAT_INT_RConfirmed
- Service 22
DID 2A0E - Module
710 → 77A - Every
5 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51
- Unit
- Raw value
0x1F = 31 → = 6.2
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Battery internal resistance, raw TARRACO_BAT_INTERNAL_RES_RAW
- Service 22
DID 2A25 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51
- Unit
- Raw value
In testing for 2018 to 2026.
Battery sensor temperature TARRACO_MQB_BAT_SEN_TConfirmed
- Service 22
DID 2A0A - Module
710 → 77A - Every
5 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x00 = 0 → = -40 °C
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Battery temperature TARRACO_BAT_TConfirmed
- Service 22
DID 2A0B - Module
710 → 77A - Every
5 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x00 = 0 → = -40 °C
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Battery total charge TARRACO_MQB_BAT_TOT_CHGConfirmed
- Service 22
DID 2A61 - Module
710 → 77A - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
0x00000000 = 0 → = 0 Ah
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Battery total discharge TARRACO_MQB_BAT_TOT_DISConfirmed
- Service 22
DID 2A61 - Module
710 → 77A - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
0x00000000 = 0 → = 0 Ah
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Battery voltage TARRACO_BAT_V_2A07Confirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 2A07 - Module
710 → 77A - Every
5 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 4 to 69.535 V
- Unit
- V
0x1EA6 = 7846 → = 11.846 V
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Battery voltage TARRACO_BATTERY_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 105A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655360 to 655340 mV
- Unit
- mV
In testing for 2018 to 2026.
Battery voltage at rest TARRACO_BAT_V_AT_RESTConfirmed
- Service 22
DID 2A10 - Module
710 → 77A - Every
5 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 9 to 34.5 V
- Unit
- V
0x21 = 33 → = 12.3 V
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Bypass valve high pressure turbine inlet, raw voltage TARRACO_BYPASS_VLV_HIGH_P_V
- Service 22
DID 3D01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2018 to 2026.
Charge air pressure TARRACO_PQ35_CHG_AIR_PConfirmed
- Service 22
DID 2211 - Module
714 → 77E - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0D = 13 → = 5.098039 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Charge air pressure actuator, acknowledgment TARRACO_CHG_AIR_P_ACTUATOR
- Service 22
DID 2065 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Charge pressure actuator, actual position TARRACO_CHG_P_ACTUATOR_ACT
- Service 22
DID 39A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure actuator, adaptation for lower stop TARRACO_CHG_P_ACTUATOR_ADPT
- Service 22
DID 39A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2018 to 2026.
Charge pressure actuator, adaptation for upper stop TARRACO_CHG_P_ACTUATOR_ADPT_HI
- Service 22
DID 39A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2018 to 2026.
Charge pressure actuator, maximum sensor voltage TARRACO_CHG_P_ACTUATOR_MAX_V
- Service 22
DID 3D77 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 mV
- Unit
- mV
In testing for 2018 to 2026.
Charge pressure actuator, specified position TARRACO_CHG_P_ACTUATOR_SPEC
- Service 22
DID 39A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure actuator, specified value TARRACO_CHG_P_ACTUATOR_SPEC_7E0
- Service 22
DID 39A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure control adaptation higher than max. threshold TARRACO_CHG_P_CTRL_ADPT_MAX
- Service 22
DID 293E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure control adaptation lower than min. threshold TARRACO_CHG_P_CTRL_ADPT_LO_MIN
- Service 22
DID 293F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure control valve activation pulse duty factor TARRACO_CHG_P_CTRL_VLV
- Service 22
DID 3EA9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure control valve position, actual value TARRACO_CHG_P_CTRL_VLV_POS_ACT
- Service 22
DID 3EA7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure control valve position, target value TARRACO_CHG_P_CTRL_VLV_POS_TGT
- Service 22
DID 3EA6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Charge pressure control valve sensor voltage TARRACO_CHG_P_CTRL_VLV_SENS_V
- Service 22
DID 3EA8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2018 to 2026.
Charge pressure control valve voltage, position closed TARRACO_CHG_P_CTRL_VLV_V_POS
- Service 22
DID 3EAB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2018 to 2026.
Charge pressure control valve voltage, position opened TARRACO_CHG_P_CTRL_VLV_V_POS_OPENED
- Service 22
DID 3EAC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2018 to 2026.
Charge pressure regulator, lower threshold adaptation TARRACO_CHG_P_REGULATOR_LO
- Service 22
DID 16EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2018 to 2026.
Charge pressure regulator, upper threshold adaptation TARRACO_CHG_P_REGULATOR_HI
- Service 22
DID 16ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2018 to 2026.
Charge pressure sensor, unconditioned voltage TARRACO_CHG_P_SENS_V
- Service 22
DID 29C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Control module voltage TARRACO_VPWRConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID F442 - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
0x2DB4 = 11700 → = 11.7 V
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Cylinder charge specified value TARRACO_CYL_CHG_SPEC
- Service 22
DID 432F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2018 to 2026.
Cylinder charge, actual value TARRACO_CYL_CHG_ACT
- Service 22
DID 4367 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2018 to 2026.
Diesel particulate filter heat voltage TARRACO_DPF_HEAT_V
- Service 22
DID 44FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2018 to 2026.
eCall battery charge level TARRACO_ECALL_SOCConfirmed
- Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x64 = 100 → 100 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
eCall battery status TARRACO_ECALL_STATUSConfirmed
- Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
0x02 = 2 → NORMAL
| Raw value | State |
|---|---|
1 | CRITICAL |
2 | NORMAL |
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Generator target voltage TARRACO_MQB_GEN_TRG_VConfirmed
- Service 22
DID 2A00 - Module
710 → 77A - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 10.6 to 36.1 V
- Unit
- V
0x18 = 24 → = 13 V
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Generator voltage, actual TARRACO_GEN_V_ACT
- Service 22
DID 4F00 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 36.1 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensors average voltage bank 1, variant 2 TARRACO_KNOCK_SENSORS_AVG_V_1_2
- Service 22
DID 4E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Maximum charge current TARRACO_MAX_CHA_CUR_2Confirmed
- Service 22
DID 1159 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3200 to 3200 A
- Unit
- A
0x0000 = 0 → = 0 A
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Maximum discharge current TARRACO_MAX_DCHA_CUR_2Confirmed
- Service 22
DID 1158 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3200 to 3200 A
- Unit
- A
0x0000 = 0 → = 0 A
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Temperature sensor for engine temperature management voltage TARRACO_T_SENS_ENG_T_V
- Service 22
DID 40E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Turbocharger inlet pressure corrected value TARRACO_TURBOCHARGER_INLET_P
- Service 22
DID 11D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2018 to 2026.
Usable battery charge TARRACO_USE_BAT_CHGConfirmed
- Service 22
DID 2A0F - Module
710 → 77A - Every
5 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 Ah
- Unit
- Ah
0x1A = 26 → 26 Ah
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Climate
A/C compressor torque, requested TARRACO_AC_COMP_TConfirmed
- Service 22
DID 1002 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
0x0000 = 0 → = 0 N·m
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Ambient temperature TARRACO_AAT_V2Confirmed
- Service 22
DID 1004 - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -255 to 255 °C
- Unit
- °C
0x0000 = 0 → = 0 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Cabin humidity TARRACO_CABIN_HUMIDITYConfirmed
- Service 22
DID 27C4 - Module
746 → 7B0 - Every
1 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x54 = 84 → = 42 %
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Outside temperature TARRACO_AATConfirmed
- Service 22
DID 2609 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -64 to 63.5 °C
- Unit
- °C
0x01 = 1 → = 0.5 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Recirculation flap actual position TARRACO_MQB_RECIRC_FLAP_ACTConfirmed
- Service 22
DID 261E - Module
746 → 7B0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x01AA = 426 → 426
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Recirculation flap fresh air threshold TARRACO_MQB_RECIRC_FLAP_FRESH_THRConfirmed
- Service 22
DID 2620 - Module
746 → 7B0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x00A8 = 168 → 168
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Recirculation flap target position TARRACO_MQB_RECIRC_FLAP_TRGConfirmed
- Service 22
DID 261F - Module
746 → 7B0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x01AC = 428 → 428
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Recirculation flap threshold TARRACO_MQB_RECIRC_FLAP_THRConfirmed
- Service 22
DID 2621 - Module
746 → 7B0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0353 = 851 → 851
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Windshield temperature TARRACO_WINDSHIELD_TConfirmed
- Service 22
DID 27C4 - Module
746 → 7B0 - Every
1 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -38.8 to 108.08 °C
- Unit
- °C
0x01 = 1 → = -38.224 °C
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Clocks
Time since engine start TARRACO_RUNTMConfirmed
How long it's been since the engine started.
- Service 22
DID F41F - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
0x0000 = 0 → 0 s
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022. Supported for 2021.
Brake booster low pressure, actual TARRACO_BRAKE_BOOSTER_LOW_P_ACT
- Service 22
DID 1490 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559.9937
- Unit
- Raw value
In testing for 2018 to 2026.
Brake booster raw pressure TARRACO_BRAKE_BOOSTER_RAW_P
- Service 22
DID 11D1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Brake pedal position TARRACO_BRAKE_PEDAL_POS
- Service 22
DID 105D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Brake pressure TARRACO_BRAKE_P
- Service 22
DID 2B21 - Module
713 → 77D - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -543.8501 to 458.8288 bar
- Unit
- bar
In testing for 2018 to 2026.
Hydraulic brake booster: active TARRACO_HYD_BRAKE_BOOST_ACTIVEConfirmed
- Service 22
DID 1810 - Module
713 → 77D - Every
2 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Pressure in brake servo unit TARRACO_P_BRAKE_SERVO_UNIT
- Service 22
DID 2005 - Module
713 → 77D - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375
- Unit
- Raw value
In testing for 2018 to 2026.
Requested brake torque, auxiliary system TARRACO_REQ_BRAKE_TQ
- Service 22
DID 1610 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2018 to 2026.
DTCs
Distance traveled since diagnostic trouble codes cleared TARRACO_CLR_DISTConfirmed
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 22
DID F431 - Module
7E0 → 7E8 - Every
30 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x2489 = 9353 → 9,353 km
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Distance traveled while mil was activated TARRACO_MIL_DISTConfirmed
- Service 22
DID F421 - Module
7E0 → 7E8 - Every
30 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x0000 = 0 → 0 km
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Number of warm-ups since diagnostic trouble codes cleared TARRACO_WARM_UPSConfirmed
- Service 22
DID F430 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0xFF = 255 → 255
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
ECU
Misfires, cylinder 2 TARRACO_MISFIRES__CYL__2Confirmed
- Service 22
DID 1152 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0D83 = 3459 → 3,459
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Misfires, cylinder 4 TARRACO_MISFIRES__CYL__4Confirmed
- Service 22
DID 1151 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0950 = 2384 → 2,384
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engine
A/C clutch TARRACO_CLIMATE_A_C_CLCHConfirmed
- Service 22
DID 482B - Module
746 → 7B0 - Every
2 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
A/C compressor load TARRACO_CLIMATE_A_C_COMP_LOADConfirmed
- Service 22
DID 2604 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 N·m
- Unit
- N·m
0x00 = 0 → = 0 N·m
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
A/C compressor torque TARRACO_A_C_COMPRESSOR_TORQUE
- Service 22
DID 101A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
A/C refrigerant pressure TARRACO_A_C_REFRIGERANT_PRES
- Service 22
DID 1017 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2018 to 2026.
Adaptation of throttle valve TARRACO_ADPT_THROTTLE_VLV
- Service 22
DID 292B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Air conditioning compressor pressure, linear raw value TARRACO_AC_COMP_P_LINEAR_RAW
- Service 22
DID 15C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070
- Unit
- Raw value
In testing for 2018 to 2026.
Air conditioning compressor torque TARRACO_AC_COMP_TQ
- Service 22
DID 2017 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Air conditioning refrigerant pressure TARRACO_AC_REFRIGERANT_P
- Service 22
DID 412A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2018 to 2026.
Air filling TARRACO_AIR_FILLING
- Service 22
DID 121C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Air leakage TARRACO_AIR_LEAKAGE
- Service 22
DID 11B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Air mass, actual value, mg/stroke TARRACO_AIR_MASS_ACT_MG
- Service 22
DID 29D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2026.
Air pollution level TARRACO_CLIMATE_AIR_POLUTION_LVLConfirmed
- Service 22
DID 26ED - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -12.8 to 12.7
- Unit
- Number
0x00 = 0 → = 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Ambient air pressure TARRACO_AMBIENT_AIR_P
- Service 22
DID 1509 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2555.8649
- Unit
- Raw value
In testing for 2018 to 2026.
Ambient air temperature TARRACO_DASH_AMBIENT_AIR_TConfirmed
- Service 22
DID 1014 - Module
714 → 77E - Every
5 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
0x64 = 100 → = 0 °C
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Analysis, clutch 1, maximum temperature TARRACO_ANALYSIS_CLU_1_MAX_T
- Service 22
DID 1064 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2018 to 2026.
Analysis, clutch 2, maximum temperature TARRACO_ANALYSIS_CLU_2_MAX_T
- Service 22
DID 1079 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2018 to 2026.
Automatic engine starts counter TARRACO_AUTOMATIC_ENG_STARTS
- Service 22
DID 2999 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Automatic transmission fluid temperature, variant 2 TARRACO_MQB_TCM_ATF_T_VAR_2_DSG_S_TRONICConfirmed
- Service 22
DID 2104 - Module
7E1 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
0x0008 = 8 → 8 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Average ignition timing angle delay adjustment TARRACO_AVG_IGN_TIM_ANG
- Service 22
DID 2949 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Avg. injection time TARRACO_AVG_INJ_TIME
- Service 22
DID 128C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1717986 ms
- Unit
- ms
In testing for 2018 to 2026.
Avg. injection time TARRACO_AVG_INJ_TIME_7E0
- Service 22
DID 2003 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25 ms
- Unit
- ms
In testing for 2018 to 2026.
Basic correction factor:, cylinder 1, filtered TARRACO_BASIC_CORR_FACTOR_1
- Service 22
DID 171A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2018 to 2026.
Basic correction factor:, cylinder 2, filtered TARRACO_BASIC_CORR_FACTOR_2
- Service 22
DID 171D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2018 to 2026.
Basic correction factor:, cylinder 3, filtered TARRACO_BASIC_CORR_FACTOR_3
- Service 22
DID 171B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2018 to 2026.
Basic correction factor:, cylinder 4, filtered TARRACO_BASIC_CORR_FACTOR_4
- Service 22
DID 171C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2018 to 2026.
Boost pressure actuator, commanded duty TARRACO_BOOST_P_ACTUATOR_CMD
- Service 22
DID 16EE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.993 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Boost pressure commanded TARRACO_PQ35_BOOST_P_CMDConfirmed
- Service 22
DID 1149 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
0x0000 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Boost pressure, actual TARRACO_BOOST_P_ACT
- Service 22
DID 11F0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2018 to 2026.
Boost regulation duty, commanded value TARRACO_BOOST_REGULATION_CMD
- Service 22
DID 1219 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Bypass valve high pressure turbine inlet, activation TARRACO_BYPASS_VLV_HIGH_P_TURBINE_INLET
- Service 22
DID 39FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Bypass valve high pressure turbine inlet, actual value TARRACO_BYPASS_VLV_HIGH_P_ACT
- Service 22
DID 39FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -400 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Bypass valve high pressure turbine inlet, offset closed TARRACO_BYPASS_VLV_HIGH_P
- Service 22
DID 39FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Bypass valve high pressure turbine inlet, offset open TARRACO_BYPASS_VLV_HIGH_P_TURBINE
- Service 22
DID 39FE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Bypass valve high pressure turbine inlet, target value TARRACO_BYPASS_VLV_HIGH_P_TGT
- Service 22
DID 39FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -400 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Cabin temperature TARRACO_CABIN_TConfirmed
- Service 22
DID 2613 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x0002 = 2 → = 0.2 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022. Supported for 2021.
Camshaft adaptation exhaust bank 1, phase position TARRACO_CAM_ADPT_EXH_BANK_1_PHASE
- Service 22
DID 2023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adaptation intake bank 1, phase position TARRACO_CAM_ADPT_INT_BANK_1_PHASE
- Service 22
DID 2021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adaptation, counter due to knock TARRACO_CAM_ADPT_CNT_KNOCK
- Service 22
DID 523B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Camshaft adaptation, exhaust bank 1, phase position TARRACO_CAM_ADPT_EXH_BANK_1
- Service 22
DID 1128 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adaptation, intake bank 1, phase position TARRACO_CAM_ADPT_INT_BANK_1
- Service 22
DID 1125 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adaptation, intake deviation TARRACO_CAM_ADPT_INT_DEV
- Service 22
DID 4FF5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -256 to 255.9921 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment intake bank 1, activation % TARRACO_CAM_ADJ_INT_BANK_1
- Service 22
DID 2930 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Camshaft adjustment intake test bank 1 TARRACO_CAM_ADJ_INT_TEST_1
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Camshaft adjustment outlet test bank 1 TARRACO_CAM_ADJ_OUTLET_TEST_1
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Camshaft adjustment, exhaust bank 1, actual value TARRACO_CAM_ADJ_EXH_BANK_1_ACT
- Service 22
DID 136C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, exhaust bank 1, specified value TARRACO_CAM_ADJ_EXH_BANK_1_SPEC
- Service 22
DID 1371 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, exhaust, actual value TARRACO_CAM_ADJ_EXH_ACT
- Service 22
DID 201A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, exhaust, specified value TARRACO_CAM_ADJ_EXH_SPEC
- Service 22
DID 2019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, intake bank 1, actual value TARRACO_CAM_ADJ_INT_BANK_1_ACT
- Service 22
DID 136E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, intake bank 1, specified value TARRACO_CAM_ADJ_INT_BANK_1_SPEC
- Service 22
DID 1373 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, intake, actual value TARRACO_CAM_ADJ_INT_ACT
- Service 22
DID 201E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft adjustment, intake, specified value TARRACO_CAM_ADJ_INT_SPEC
- Service 22
DID 201D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Camshaft end position TARRACO_PQ35_CAMS_ENDConfirmed
- Service 22
DID 1341 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 °
- Unit
- °
0x0302 = 770 → = 154 °
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Camshaft position, deviation from the base position TARRACO_CAM_POS_DEV_BASE_POS
- Service 22
DID 1385 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2018 to 2026.
Cat. converter oxygen storage capacity measured TARRACO_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED
- Service 22
DID 1507 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Catalyst temperature, calculated TARRACO_CAT_T_CALC
- Service 22
DID 1515 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 1225 °C
- Unit
- °C
In testing for 2018 to 2026.
Centrifugal oil temperature TARRACO_PQ35_CENTRIFUGAL_OIL_TConfirmed
- Service 22
DID 38B2 - Module
7E1 → 7E9 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
0x51 = 81 → 81
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Chain elongation inlet, mileage at last adaptation TARRACO_CHAIN_ELONGATION_INLET
- Service 22
DID 516C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2018 to 2026.
Chain elongation outlet, mileage at last adaptation TARRACO_CHAIN_ELONGATION
- Service 22
DID 5149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2018 to 2026.
Chain elongation, no of valid initial values, exhaust bank 1 TARRACO_CHAIN_ELONGATION_NO_VALID_1
- Service 22
DID 4189 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Chain elongation, no of valid initial values, intake bank 1 TARRACO_CHAIN_ELONGATION_NO_1
- Service 22
DID 4187 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Clutch center central plate temperature TARRACO_CLU_CENTER_CENTRAL_T
- Service 22
DID 102A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2018 to 2026.
Commanded crankshaft torque TARRACO_CMD_CRANK_TQ
- Service 22
DID 11E0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2022.
Control module temperature TARRACO_MQB_TCM_ECU_TConfirmed
- Service 22
DID 028D - Module
7E1 → 7E9 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
0x52 = 82 → 82 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Converter loss torque TARRACO_MQB_TCM_CONVERTER_LOSS_TORQUEConfirmed
- Service 22
DID 1010 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
0x5000 = 20480 → = 1,024 N·m
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Coolant circulation pump, activation TARRACO_CLT_CIRCULATION_PMP_ACTIVATION
- Service 22
DID 276D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant circulation pump, control TARRACO_CLT_CIRCULATION_PMP
- Service 22
DID 167E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant fan 1, activation TARRACO_CLT_FAN_1_ACTIVATION
- Service 22
DID 2055 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant fan 1, activation TARRACO_COOLANT_FAN_1_ACTIVATION
- Service 22
DID 1130 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant fan 2, activation TARRACO_CLT_FAN_2_ACTIVATION
- Service 22
DID 2056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant fan, requested by A/C TARRACO_CLT_FAN_REQ_AC
- Service 22
DID 1018 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Coolant shut-off valve, closed TARRACO_CLT_SHUT_OFF_VLV
- Service 22
DID 2682 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2018 to 2026.
Coolant temperature at engine outlet, calculated TARRACO_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED
- Service 22
DID 4490 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at engine start TARRACO_COOLANT_T_AT_ENGINE_START
- Service 22
DID 1291 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at engine start TARRACO_ECT_ENG_START
- Service 22
DID 2935 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at radiator outlet TARRACO_COOLANT_TConfirmed
- Service 22
DID 1135 - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
0x0E63 = 3683 → = 95.2 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Coolant temperature at radiator outlet v.1 TARRACO_ECT_RADIATOR_OUTLET_V_1
- Service 22
DID 15CD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at radiator outlet, actual value TARRACO_ECT_RADIATOR_OUTLET_ACT
- Service 22
DID 202B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature at radiator outlet, specified value TARRACO_ECT_RADIATOR_OUTLET_SPEC
- Service 22
DID 202C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature difference between engine and radiator TARRACO_ECT_DIFF_ENG
- Service 22
DID 202E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature linear TARRACO_ECT_LINEAR
- Service 22
DID 1513 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -48 to 143.9978 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature modeled value TARRACO_COOLANT_T_MODELED_VALUE
- Service 22
DID 13A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature, maximum value TARRACO_ECT_MAX
- Service 22
DID 1511 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2018 to 2026.
Coolant temperature, minimum value TARRACO_ECT_MIN
- Service 22
DID 1512 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2018 to 2026.
Correction values for main pressure adaptation TARRACO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPTConfirmed
- Service 22
DID 11A7 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
0x0046 = 70 → = 0.7 bar
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Crankshaft rotation angle when closing the quantity control valve TARRACO_CRANK_ROT_ANG
- Service 22
DID 10EB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Critical engine oil level TARRACO_PQ35_OIL_LVL_CRITConfirmed
- Service 22
DID 11BD - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -131.072 to 131.068 mm
- Unit
- mm
0x0ABC = 2748 → = 10.992 mm
Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.
CTR_MIS_DC_MMV_CYL_SAE, 0 TARRACO_CTR_MIS_DC_MMV_CYL_0
- Service 22
DID 148D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 1 TARRACO_CTR_MIS_DC_MMV_CYL_1
- Service 22
DID 148E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 2 TARRACO_CTR_MIS_DC_MMV_CYL_2
- Service 22
DID 148F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Cylinder block temperature sensor TARRACO_CYL_BLOCK_T_SENS
- Service 22
DID 51D4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Cylinder head temperature TARRACO_CYL_HEAD_T
- Service 22
DID 1065 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2018 to 2026.
Diesel particulate filter air pressure sensor raw value TARRACO_DPF_AIR_P_SENS_RAW
- Service 22
DID 4494 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Diesel particulate filter ash load limit TARRACO_DPF_ASH_LOAD_LIM
- Service 22
DID 406B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511.9921
- Unit
- Raw value
In testing for 2018 to 2026.
Diesel particulate filter cleaning deviation reaction time TARRACO_DPF_CLEANING_DEV
- Service 22
DID 44F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767
- Unit
- Number
In testing for 2018 to 2026.
Diesel particulate filter counter for regeneration time TARRACO_DPF_CNT_REGEN_TIME
- Service 22
DID 39F9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 41942.4 s
- Unit
- s
In testing for 2018 to 2026.
Diesel particulate filter differential pressure sensor temperature TARRACO_DPF_DIFF_P_SENS_T
- Service 22
DID 43C0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -689.9918 to 589.9722 °C
- Unit
- °C
In testing for 2018 to 2026.
Diesel particulate filter differential pressure, dynamic offset TARRACO_MQB_DPF_DIFF_P_DYNAMIC_OFFSETConfirmed
- Service 22
DID 15B8 - Module
7E0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
0x04DF = 1247 → 1,247
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Diesel particulate filter differential pressure, raw value 1 TARRACO_DPF_DIFF_P_RAW_1
- Service 22
DID 43BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Diesel particulate filter differential pressure, raw value 2 TARRACO_DPF_DIFF_P_RAW_2
- Service 22
DID 43BF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2018 to 2026.
Diesel particulate filter exhaust gas flow volume TARRACO_MQB_DPF_EXH_VOLConfirmed
- Service 22
DID 11E6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Number
0x003E = 62 → = 6.2
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Diesel particulate filter exhaust temperature TARRACO_DPF_EXH_T
- Service 22
DID 44F8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Diesel particulate filter input temperature raw value TARRACO_DPF_INPUT_T_RAW
- Service 22
DID 449B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Diesel particulate filter output temperature raw value TARRACO_DPF_OUTPUT_T_RAW
- Service 22
DID 449A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Diesel particulate filter regeneration level current TARRACO_DPF_REGEN_LEVEL
- Service 22
DID 080D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Diesel particulate filter regeneration request status TARRACO_DPF_REGEN_REQ_STAT
- Service 22
DID 2087 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Diesel particulate filter regeneration status TARRACO_DPF_REGEN_STAT
- Service 22
DID 0809 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Diesel particulate filter regeneration, cancel conditions TARRACO_DPF_REGEN_CANCEL
- Service 22
DID 29F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Diesel particulate filter soot measured TARRACO_DPF_SOOT_MEAS
- Service 22
DID 208C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2018 to 2026.
Diesel particulate filter surface temperature TARRACO_DPF_SURFACE_T
- Service 22
DID 44FB - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2321.15 to 1774.7875 °C
- Unit
- °C
In testing for 2018 to 2026.
Diesel particulate filter time since last regeneration TARRACO_DPF_TIME_SINCE_REGEN
- Service 22
DID 2089 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 127.9964 h
- Unit
- h
In testing for 2018 to 2026.
Driver demand torque TARRACO_MQB_TCM_DRIVER_DEMAND_TORQUEConfirmed
- Service 22
DID 100B - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
0x5C03 = 23555 → = 1,177.75 N·m
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Dynamic average of ignition angle delay adjustment TARRACO_DYNAMIC_AVG_IGN_ANG
- Service 22
DID 294A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Ea888b boost pressure control, adaptation value 0 TARRACO_EA888B_BOOST_P_CTRL_0
- Service 22
DID 11FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2018 to 2026.
Ea888b boost pressure control, adaptation value 1 TARRACO_EA888B_BOOST_P_CTRL_1
- Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2018 to 2026.
Ea888b boost pressure control, adaptation value 2 TARRACO_EA888B_BOOST_P_CTRL_2
- Service 22
DID 1201 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2018 to 2026.
Ea888b boost pressure control, adaptation value 3 TARRACO_EA888B_BOOST_P_CTRL_3
- Service 22
DID 1202 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2018 to 2026.
Ea888b boost pressure regulator, commanded TARRACO_EA888B_BOOST_P_CMD
- Service 22
DID 11A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Early ignition counter, cylinder 1 TARRACO_EARLY_IGN_CNT_CYL_1
- Service 22
DID 1722 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder 2 TARRACO_EARLY_IGN_CNT_CYL_2
- Service 22
DID 1725 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder 3 TARRACO_EARLY_IGN_CNT_CYL_3
- Service 22
DID 1723 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, cylinder 4 TARRACO_EARLY_IGN_CNT_CYL_4
- Service 22
DID 1724 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, total, cylinder 1 TARRACO_EARLY_IGN_CNT_TOT_1
- Service 22
DID 1715 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, total, cylinder 2 TARRACO_EARLY_IGN_CNT_TOT_2
- Service 22
DID 1718 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, total, cylinder 3 TARRACO_EARLY_IGN_CNT_TOT_3
- Service 22
DID 1716 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Early ignition counter, total, cylinder 4 TARRACO_EARLY_IGN_CNT_TOT_4
- Service 22
DID 1717 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Effective injection duration TARRACO_EFFECTIVE_INJ_DUR
- Service 22
DID 15E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2018 to 2026.
Electric additional coolant pump control, high circle TARRACO_ELEC_ADDITIONAL_CLT
- Service 22
DID 1488 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Engine air mass, specified value TARRACO_ENG_AIR_MASS_SPEC
- Service 22
DID 2037 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Engine control module temperature TARRACO_ENG_CTRL_MODULE_TConfirmed
- Service 22
DID 028D - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x0AD3 = 2771 → = 277.1 °C
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022. Supported for 2021.
Engine drag torque TARRACO_ENG_DRAG_TQ
- Service 22
DID 209C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine oil level TARRACO_PQ35_OIL_LVL
- Service 22
DID 11BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -131.072 to 131.068 mm
- Unit
- mm
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Engine oil level current value TARRACO_ENG_OIL_LEVEL
- Service 22
DID 58D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Engine oil sump temperature TARRACO_ENG_OIL_SUMP_T
- Service 22
DID 15B7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2018 to 2026.
Engine oil temperature TARRACO_EOT
- Service 22
DID 202F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Engine oil temperature sensor 2 TARRACO_EOT_SENS_2
- Service 22
DID 40D5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Engine outlet coolant temperature calculated TARRACO_ENG_OUTLET_ECT_CALC
- Service 22
DID 1063 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Engine protection, torque limit TARRACO_ENG_PROTECTION_TQ
- Service 22
DID 2BC0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine read 11BE, signed raw count TARRACO_11BE_RAWConfirmed
- Service 22
DID 11BE - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
0xFFDE = -34 → -34
Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.
Engine read 162D, raw count TARRACO_162D_RAWConfirmed
- Service 22
DID 162D - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
0x80000000 = 2147483648 → 2,147,483,648
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engine temperature control actuator TARRACO_ENG_T_CTRL_ACTUATOR
- Service 22
DID 3D73 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Engine temperature management actuator, after-run stop TARRACO_ENG_T_MANAGEMENT_ACTUATOR_AFTER
- Service 22
DID 441D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Engine temperature management actuator, duty cycle activation TARRACO_ENG_T_MANAGEMENT_ACTUATOR
- Service 22
DID 441A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Engine temperature management actuator, raw value TARRACO_ENG_T_MANAGEMENT
- Service 22
DID 4419 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Engine temperature management actuator, specified value TARRACO_ENG_T_MANAGEMENT_SPEC
- Service 22
DID 3FE4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Engine temperature management actuator, stop open TARRACO_ENG_T_MANAGEMENT_ACTUATOR_STOP
- Service 22
DID 441C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Engine torque TARRACO_ENG_TQ
- Service 22
DID 2002 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque TARRACO_ENG_TQ_7E0
- Service 22
DID 437C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque TARRACO_ENG_TQ_7E1
- Service 22
DID 2002 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque TARRACO_ENGINE_TORQUE
- Service 22
DID 1010 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Engine torque TARRACO_MQB_TCM_ENGINE_TORQUEConfirmed
- Service 22
DID 100C - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
0x03C0 = 960 → = 48 N·m
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engine torque limitation TARRACO_MQB_TCM_ENGINE_TORQUE_LIMITATIONConfirmed
- Service 22
DID 100E - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
0x1540 = 5440 → = 272 N·m
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engine torque loss TARRACO_MQB_TCM_ENGINE_TORQUE_LOSSConfirmed
- Service 22
DID 100F - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
0xFEAC = -340 → = -17 N·m
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Exhaust camshaft, adaptation bias TARRACO_EXH_CAM_ADPT_BIAS
- Service 22
DID 174A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2018 to 2026.
Exhaust camshaft, adaptation sensor tolerance TARRACO_EXH_CAM_ADPT_SENS
- Service 22
DID 1755 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2018 to 2026.
Exhaust gas jet volume in particle filter TARRACO_EXH_GAS_JET_VOLUME
- Service 22
DID 3D7E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700 L
- Unit
- L
In testing for 2018 to 2026.
Exhaust gas temperature TARRACO_EXH_GAS_T
- Service 22
DID F43C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature - calculated after catalyst TARRACO_EXH_GAS_T_CALC_AFTER
- Service 22
DID 2AE9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.9904 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature at probe before precat, model value TARRACO_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE
- Service 22
DID 139C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature before catalyst TARRACO_EXHAUST_GAS_T_BEFORE_CATALYSTConfirmed
- Service 22
DID 1282 - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -193.93 to 1116.77 °C
- Unit
- °C
0x78DC = 30940 → = 424.87 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Exhaust gas temperature before catalytic converter TARRACO_EXH_GAS_T_BEFORE
- Service 22
DID 296F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature before gasoline particulate filter TARRACO_EXH_GAS_T_BEFORE_GPF
- Service 22
DID 082D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust gas temperature sensor 1 TARRACO_EXH_GAS_T_SENS_1
- Service 22
DID 2976 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Exhaust temperature before the catalyst, modeled TARRACO_EXH_T_BEFORE_CAT
- Service 22
DID 1421 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Front left deflector temperature TARRACO_CLIMATE_FR_L_DEFL_TConfirmed
- Service 22
DID 260C - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Front left temperature flap actual value TARRACO_CLIMATE_FR_L_T_FLP_ACT_VALUEConfirmed
- Service 22
DID 2622 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Front right deflector temperature TARRACO_CLIMATE_FR_R_DEFL_TConfirmed
- Service 22
DID 260D - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
0x03 = 3 → = 1 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Front right temperature flap actual value TARRACO_CLIMATE_FR_R_T_FLP_ACT_VALUEConfirmed
- Service 22
DID 2626 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Fuel metering valve position TARRACO_PQ35_FUEL_METERConfirmed
- Service 22
DID 1148 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Gasoline particulate filter blockage rate calculated TARRACO_GPF_BLOCKAGE_RATE_CALC
- Service 22
DID 2AFB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 51.1992
- Unit
- Number
In testing for 2018 to 2026.
Gasoline particulate filter blockage rate threshold calculated TARRACO_GPF_BLOCKAGE_RATE
- Service 22
DID 2AF9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 51.1992
- Unit
- Number
In testing for 2018 to 2026.
Gasoline particulate filter blockage ratio calculated absolute TARRACO_GPF_BLOCKAGE_RAT
- Service 22
DID 0827 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
In testing for 2018 to 2026.
Gasoline particulate filter blockage ratio calculated relative TARRACO_GPF_BLOCKAGE_RAT_CALC_REL
- Service 22
DID 0828 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
In testing for 2018 to 2026.
Gasoline particulate filter high level moisture build-up TARRACO_GPF_HIGH_LEVEL
- Service 22
DID 24B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107
- Unit
- Raw value
In testing for 2018 to 2026.
Gasoline particulate filter high level of soot build-up TARRACO_GPF_HIGH_LEVEL_SOOT
- Service 22
DID 24B3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Gasoline particulate filter loading stage TARRACO_GPF_LOADING_STAGE
- Service 22
DID 082B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Gasoline particulate filter maximum ash build-up reached TARRACO_GPF_MAX_ASH_BUILD_UP
- Service 22
DID 24B5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 510
- Unit
- Raw value
In testing for 2018 to 2026.
Gasoline particulate filter maximum soot build-up reached TARRACO_GPF_MAX_SOOT_BUILD
- Service 22
DID 24B4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Gasoline particulate filter oil ash load calculated TARRACO_GPF_OIL_ASH_LOAD
- Service 22
DID 0804 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Gasoline particulate filter oil ash mass TARRACO_GPF_OIL_ASH_MASS
- Service 22
DID 406C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2018 to 2026.
Gasoline particulate filter soot load calculated TARRACO_GPF_SOOT_LOAD_CALC
- Service 22
DID 0829 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Gasoline particulate filter soot mass calculated TARRACO_GPF_SOOT_MASS_CALC
- Service 22
DID 208B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Gasoline particulate filter water load TARRACO_GPF_WATER_LOAD
- Service 22
DID 0802 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Gasoline particulate filter water mass TARRACO_GPF_WATER_MASS
- Service 22
DID 2139 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107
- Unit
- Raw value
In testing for 2018 to 2026.
Generator current TARRACO_GEN_CURRENT
- Service 22
DID 2A1C - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6562.5 A
- Unit
- A
In testing for 2018 to 2026.
Generator load TARRACO_PQ35_GEN_LOADConfirmed
- Service 22
DID 105C - Module
7E0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Generator load normalized value TARRACO_GENERATOR_LOAD_NORMALIZED_VALUE
- Service 22
DID 15CA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Generator load signal TARRACO_GEN_LOAD_SIG
- Service 22
DID 2050 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Generator load signal TARRACO_GENERATOR_LOAD_SIG
- Service 22
DID 101C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Generator performance TARRACO_GENERATOR_PERFORMANCE
- Service 22
DID 1097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -308831.8464 to 308822.421 W
- Unit
- W
In testing for 2018 to 2026.
Generator torque request TARRACO_GENERATOR_TORQUE_REQUEST
- Service 22
DID 101B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Heater circulation pump, nominal value TARRACO_HEATER_CIRCULATION
- Service 22
DID 167F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Heater for nozzles active TARRACO_HEATER_FOR_NOZZLES_ACTIVEConfirmed
- Service 22
DID 1945 - Module
70E → 778 - Every
2 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x0E = 14 → 14
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Heater support pump, specified value TARRACO_HEATER_SUPPORT_PMP_SPEC
- Service 22
DID 4336 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Height correction TARRACO_HEIGHT_CORR
- Service 22
DID 1136 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3.9999
- Unit
- Number
In testing for 2018 to 2026.
High pressure control, adaptation TARRACO_HIGH_P_CTRL_ADPT
- Service 22
DID 11D2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16.384 to 16.3835
- Unit
- Raw value
In testing for 2018 to 2026.
IGA_CYL_KNK, 0 TARRACO_IGA_CYL_KNK_0
- Service 22
DID 13F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2018 to 2026.
IGA_CYL_KNK, 1 TARRACO_IGA_CYL_KNK_1
- Service 22
DID 13F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2018 to 2026.
IGA_CYL_KNK, 2 TARRACO_IGA_CYL_KNK_2
- Service 22
DID 13F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2018 to 2026.
IGA_CYL_KNK, 3 TARRACO_IGA_CYL_KNK_3
- Service 22
DID 13F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2018 to 2026.
IGA_IGC, 0 TARRACO_IGA_IGC_0
- Service 22
DID 138A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2018 to 2026.
IGA_IGC, 1 TARRACO_IGA_IGC_1
- Service 22
DID 138B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2018 to 2026.
IGA_IGC, 2 TARRACO_IGA_IGC_2
- Service 22
DID 138C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2018 to 2026.
IGA_IGC, 3 TARRACO_IGA_IGC_3
- Service 22
DID 138D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2018 to 2026.
Ignition angle current cylinder, actual value TARRACO_IGN_ANG_CURRENT_CYL_ACT
- Service 22
DID 2004 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -25 to 25 °
- Unit
- °
In testing for 2018 to 2026.
Ignition timing angle retard, cylinder 4 TARRACO_IGNITION_TIMING_ANGLE_RETARD_C4
- Service 22
DID 10E5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -24576 to 24575.25 °
- Unit
- °
In testing for 2018 to 2026.
Injector 2 rail pressure calibration point 1 TARRACO_PQ35_INJ_2_RAIL_P_1Confirmed
- Service 22
DID 10D3 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
0x0004 = 4 → = 0.0002 ms
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Injector 4 rail pressure calibration point 3 TARRACO_PQ35_INJ_4_RAIL_P_3Confirmed
- Service 22
DID 10DE - Module
7E0 → 7E8 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Inlet flaps - actual value TARRACO_INLET_FLAPS_ACT
- Service 22
DID 119D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Inlet flaps - requested value TARRACO_INLET_FLAPS_REQ
- Service 22
DID 11A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Intake air temperature before throttle valve, raw value TARRACO_IAT_BEFORE_THROTTLE
- Service 22
DID 15C1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2018 to 2026.
Intake air temperature in intake manifold TARRACO_INTAKE_AIR_T_IN_INTAKE_MANIFOLD
- Service 22
DID 149E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2018 to 2026.
Intake air temperature raw value TARRACO_IAT_RAW
- Service 22
DID 15C0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Intake camshaft, adaptation bias TARRACO_INT_CAM_ADPT_BIAS
- Service 22
DID 174B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2018 to 2026.
Intake camshaft, adaptation sensor tolerance TARRACO_INT_CAM_ADPT_SENS
- Service 22
DID 1740 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2018 to 2026.
Intake manifold pressure raw value TARRACO_INT_MANIFOLD_P_RAW
- Service 22
DID 3E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2018 to 2026.
Intake manifold pressure, commanded TARRACO_INT_MANIFOLD_P_CMD
- Service 22
DID 11DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2018 to 2026.
Intake manifold pressure, corrected TARRACO_INT_MANIFOLD_P
- Service 22
DID 11DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2018 to 2026.
Intake manifold runner control, acknowledgment TARRACO_INT_MANIFOLD_RUNNER_CTRL
- Service 22
DID 206A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Intake manifold runner control, activation TARRACO_INT_MANIFOLD_RUNNER
- Service 22
DID 2069 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Intake model air mass flow filtered value TARRACO_INT_MODEL_AIR_MASS
- Service 22
DID 11AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Intake phase deviation, actual value TARRACO_INT_PHASE_DEV_ACT
- Service 22
DID 1800 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2018 to 2026.
Integrated mass of air since engine start TARRACO_INTEGRATED_MASS_AIR
- Service 22
DID 1175 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 2018 to 2026.
Integrated mass of air since the first engine start TARRACO_INTEGRATED_MASS_AIR_SINCE
- Service 22
DID 1743 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 2018 to 2026.
Intercooler air output temperature TARRACO_PQ35_INTERCOOLER_AIR_OUTPUT_T
- Service 22
DID 1628 - Module
7E0 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.
Kick down TARRACO_MQB_TCM_KICK_DOWNConfirmed
- Service 22
DID 2114 - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Kilometers driven since last event on K1 TARRACO_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1Confirmed
- Service 22
DID 115A - Module
7E1 → 7E9 - Every
30 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 km
- Unit
- km
0x0002 = 2 → = 20 km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Kilometers driven since last event on K2 TARRACO_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2Confirmed
- Service 22
DID 115C - Module
7E1 → 7E9 - Every
30 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 km
- Unit
- km
0x0002 = 2 → = 20 km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Knock sensor 1 test TARRACO_KNOCK_SENS_1_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Knock sensor 2 test TARRACO_KNOCK_SENS_2_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Knock sensor 3 test TARRACO_KNOCK_SENS_3_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Knock sensor 4 test TARRACO_KNOCK_SENS_4_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Knock sensor, cylinder 1 TARRACO_KNOCK_SENS_CYL_1
- Service 22
DID 3960 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor, cylinder 1 TARRACO_KNOCK_SNS_C1_V_MS
- Service 22
DID 120E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 2018 to 2026.
Knock sensor, cylinder 2 TARRACO_KNOCK_SENS_CYL_2
- Service 22
DID 3961 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor, cylinder 2 TARRACO_KNOCK_SNS_C2_V_MS
- Service 22
DID 1211 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 2018 to 2026.
Knock sensor, cylinder 3 TARRACO_KNOCK_SENS_CYL_3
- Service 22
DID 3962 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor, cylinder 3 TARRACO_KNOCK_SNS_C3_V_MS
- Service 22
DID 120F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 2018 to 2026.
Knock sensor, cylinder 4 TARRACO_KNOCK_SENS_CYL_4
- Service 22
DID 3963 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2018 to 2026.
Knock sensor, cylinder 4 TARRACO_KNOCK_SNS_C4_V_MS
- Service 22
DID 1210 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 2018 to 2026.
Lambda value at DPF inlet TARRACO_LAMBDA_DPF_INLET
- Service 22
DID 080E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767
- Unit
- Number
In testing for 2018 to 2026.
Lambda, actual value TARRACO_LAMBDA_ACT
- Service 22
DID 10D5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.9999 to 7.9997
- Unit
- Number
In testing for 2018 to 2026.
Launch control counter, variant 1 TARRACO_LAUNCH_CTRL_CNT_VAR_1
- Service 22
DID 1200 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Launch control counter, variant 2 TARRACO_LAUNCH_CTRL_CNT_VAR_2
- Service 22
DID 38F1 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Leg deflector temperature TARRACO_CLIMATE_LEG_DEFL_TConfirmed
- Service 22
DID 2611 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Long term fuel trim at idle, direct injection TARRACO_LONG_TERM_FUEL_TRIM_IDLE
- Service 22
DID 177E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1536 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Long term fuel trim at idle, port injection TARRACO_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ
- Service 22
DID 1780 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1536 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Lower adapted coupling point K2 from micro-slip path adaptation TARRACO_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPTConfirmed
- Service 22
DID 110A - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
0x2C = 44 → = 220 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Main cat oxygen storage capacity age correction factor TARRACO_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR
- Service 22
DID 14F9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2
- Unit
- Number
In testing for 2018 to 2026.
Manifold absolute pressure, raw value TARRACO_MAP_RAW
- Service 22
DID 11DC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2018 to 2026.
Manual engine starts counter TARRACO_MANUAL_ENG_STARTS
- Service 22
DID 2998 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Mass air flow over throttle valve TARRACO_MAF_OVER_THROTTLE
- Service 22
DID 394F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Mass air flow through throttle TARRACO_MAF_THROUGH_THROTTLE
- Service 22
DID 11AC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Mass air flow, commanded TARRACO_MAF_CMD
- Service 22
DID 11AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2018 to 2026.
Mass airflow sensor 1 bank 1 raw value TARRACO_MQB_MAF_1_B1_RAWConfirmed
- Service 22
DID 1026 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
0x0000 = 0 → = 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Maximum ECU temperature TARRACO_MAX_ECU_T
- Service 22
DID 4649 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2018 to 2026.
Maximum oil level for the service interval TARRACO_MAX_OIL_LEVEL
- Service 22
DID 1230 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2018 to 2026.
Mean engine air mass TARRACO_MEAN_ENG_AIR_MASS
- Service 22
DID 2032 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Mean injection quantity TARRACO_MEAN_INJ_QTY
- Service 22
DID 2097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2018 to 2026.
Mean injection quantity TARRACO_MEAN_INJ_QUANTITYConfirmed
- Service 22
DID 1139 - Module
7E0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
0x3BF6 = 15350 → = 153.5
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Minimum oil level for the service interval TARRACO_MIN_OIL_LEVEL
- Service 22
DID 1231 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2018 to 2026.
Misfires / 1000 revolutions, cylinder 1 TARRACO_MISFIRES_1000REV_C1Confirmed
- Service 22
DID 1147 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Misfires / 1000 revolutions, cylinder 2 TARRACO_MISFIRES_1000REV_C2Confirmed
- Service 22
DID 114A - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Misfires per 1000 revolutions, cylinder 1, port injection TARRACO_MIS_PER_1000_1
- Service 22
DID 426B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires per 1000 revolutions, cylinder 2, port injection TARRACO_MIS_PER_1000_2
- Service 22
DID 426C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires per 1000 revolutions, cylinder 3, port injection TARRACO_MIS_PER_1000_3
- Service 22
DID 426D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires per 1000 revolutions, cylinder 4, port injection TARRACO_MIS_PER_1000_4
- Service 22
DID 426E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires total TARRACO_MIS_TOT
- Service 22
DID 2904 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires total TARRACO_MISFIRES_TOTALConfirmed
- Service 22
DID 1146 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Misfires, cylinder 1 TARRACO_MISFIRES_C1
- Service 22
DID 2966 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 2 TARRACO_MISFIRES_C2
- Service 22
DID 2969 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 3 TARRACO_MISFIRES_C3
- Service 22
DID 2967 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires, cylinder 3 TARRACO_MISFIRES_C3_ECMConfirmed
- Service 22
DID 1150 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0CD6 = 3286 → 3,286
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Misfires, cylinder 4 TARRACO_MISFIRES_C4
- Service 22
DID 2968 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Mixture adaptation factor at partial load TARRACO_MIXTURE_ADPT_FACTOR
- Service 22
DID 3996 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
N_32 TARRACO_N_32
- Service 22
DID 117D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2018 to 2026.
NL_PRE, 0 TARRACO_NL_PRE_0
- Service 22
DID 13F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2018 to 2026.
NL_PRE, 1 TARRACO_NL_PRE_1
- Service 22
DID 13F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2018 to 2026.
NL_PRE, 2 TARRACO_NL_PRE_2
- Service 22
DID 13F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2018 to 2026.
NL_PRE, 3 TARRACO_NL_PRE_3
- Service 22
DID 13F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2018 to 2026.
Number of injections TARRACO_NUM_INJECTIONS
- Service 22
DID 430E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Number of times the permitted centrifugal oil temperature has been exceeded TARRACO_NUM_TIMES_PERMITTED_T
- Service 22
DID 1154 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Number of warnings due to increased centrifugal oil temperature TARRACO_NUM_WARN_HI_CENTRIF_T
- Service 22
DID 1155 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Oil level TARRACO_OIL_LEVELConfirmed
- Service 22
DID 11BA - Module
7E0 - Every
30 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 26.2 cm
- Unit
- cm
0x2A17 = 10775 → = 4.31 cm
Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.
Oil level test method 1 TARRACO_OIL_LEVEL_TEST_1
- Service 22
DID 4E51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Oil level test method 2 TARRACO_OIL_LEVEL_TEST_2
- Service 22
DID 4E52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Oil level test method 3 TARRACO_OIL_LEVEL_TEST_3
- Service 22
DID 4E53 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Oil level, average dynamic value TARRACO_OIL_LEVEL_AVG
- Service 22
DID 15B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2018 to 2026.
Oil level, static measured TARRACO_OIL_LEVEL_STATIC
- Service 22
DID 15A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2018 to 2026.
Oil pressure actual current TARRACO_MQB_TCM_EOP_ACTUAL_IConfirmed
- Service 22
DID 381E - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553.5 mA
- Unit
- mA
0x1F28 = 7976 → = 797.6 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Oil pressure sensor raw value TARRACO_OIL_P_SENS_RAW
- Service 22
DID 4FBE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2018 to 2026.
Oil pressure sensor-piston cooling nozzle switch, status TARRACO_OIL_P_SENS_PISTON
- Service 22
DID 15BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Oil pressure switch activation, high pressure TARRACO_OIL_P_SWITCH_P
- Service 22
DID 20A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Oil pressure switch for high pressure, closed TARRACO_OIL_P_SWITCH_HIGH_P
- Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Oil pressure switch for low pressure, closed TARRACO_OIL_P_SWITCH_LOW_P
- Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2018 to 2026.
Oil pressure switch for piston-cooling jets, closed TARRACO_OIL_P_SWITCH_PISTON
- Service 22
DID 4270 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Oil pressure target TARRACO_OIL_P_TGT
- Service 22
DID 4F70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Oil pressure valve switch, control TARRACO_OIL_P_VLV_SWITCH
- Service 22
DID 11B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Oil thermal wear TARRACO_DASH_OIL_THERMAL_WEARConfirmed
- Service 22
DID 224B - Module
714 → 77E - Every
300 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x0068 = 104 → 104 km
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Open cam shaft angle at quantity control valve TARRACO_OPEN_CAM_SHFT_ANG
- Service 22
DID 10EA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2018 to 2026.
Outside temperature TARRACO_OUTSIDE_T
- Service 22
DID 220C - Module
714 → 77E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
In testing for 2018 to 2026.
Outside temperature, system calculated TARRACO_OUTSIDE_T_SYSTEMConfirmed
- Service 22
DID 260A - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -64 to 63.5 °C
- Unit
- °C
0x02 = 2 → = 1 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Oxygen sensor 1 bank 1 ceramic temperature TARRACO_OXYGEN_SNS_1_BANK_1_CERAMIC_T
- Service 22
DID 1290 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.793 °C
- Unit
- °C
In testing for 2018 to 2026.
Particle filter, field regeneration request status TARRACO_PARTICLE_FLT_FIELDConfirmed
- Service 22
DID 115B - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Piston cooling nozzles, control TARRACO_PISTON_COOLING
- Service 22
DID 16F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Piston-cooling jets, activation TARRACO_PISTON_COOLING_JETS
- Service 22
DID 4286 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Pre-injection 2 duration TARRACO_PQ35_PRE_INJ_2_DURATIONConfirmed
- Service 22
DID 14D1 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
0x77FF = 30719 → = 12.2876 ms
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Pressure before throttle valve - actual value TARRACO_P_BEFORE_THROTTLE_ACT
- Service 22
DID 11EE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2018 to 2026.
Pressure before throttle valve - sensor measured TARRACO_P_BEFORE_THROTTLE
- Service 22
DID 11EF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559.96
- Unit
- Raw value
In testing for 2018 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_EX_1 TARRACO_PSN_EDGE_REL_AD_CAM_1
- Service 22
DID 1184 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2018 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_EX_2 TARRACO_PSN_EDGE_REL_AD_CAM_2
- Service 22
DID 1185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2018 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_IN_1 TARRACO_PSN_EDGE_REL_AD_CAM_SAVE_1
- Service 22
DID 1186 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2018 to 2026.
Radiator fan actual duty TARRACO_CLIMATE_RAD_FAN_ACT_DUTYConfirmed
- Service 22
DID 2606 - Module
746 → 7B0 - Every
2 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Radiator fan commanded duty TARRACO_CLIMATE_RAD_FAN_CMD_DUTYConfirmed
- Service 22
DID 2607 - Module
746 → 7B0 - Every
2 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Rated drive torque TARRACO_RATED_DRIVE_TQ
- Service 22
DID 14A1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Reached maximum temperature TARRACO_PQ35_REACHED_MAXIMUM_TConfirmed
- Service 22
DID 1117 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
0x0075 = 117 → 117 °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Rear cat converter temperature, main catalytic converter model value TARRACO_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE
- Service 22
DID 1272 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Rear deflector temperature TARRACO_CLIMATE_RR_DEFL_TConfirmed
- Service 22
DID 263D - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Refrigerant pressure TARRACO_CLIMATE_REFRIG_PConfirmed
- Service 22
DID 2605 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 bar
- Unit
- bar
0x11 = 17 → = 3.4 bar
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Relative load value TARRACO_REL_LOAD
- Service 22
DID 1216 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1536.1605
- Unit
- Number
In testing for 2018 to 2026.
Relay for reserve coolant pump status TARRACO_RELAY_RESERVE_CLT
- Service 22
DID 3999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Requested torque, amount for auxiliary units TARRACO_REQ_TQ_AMOUNT
- Service 22
DID 10BE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Result of crankcase ventilation test, fail TARRACO_RESULT_CRANKCASE_VENTILATION_TEST
- Service 22
DID 15CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Result of crankcase ventilation test, successful TARRACO_RESULT_CRANKCASE
- Service 22
DID 15CB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Secondary air injection sensor 1 TARRACO_SECONDARY_AIR_INJ_1
- Service 22
DID 3F68 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2018 to 2026.
SEG_AD_MMV_ER_H, 0 TARRACO_SEG_AD_MMV_ER_H_0
- Service 22
DID 1138 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_H, 2 TARRACO_SEG_AD_MMV_ER_H_2
- Service 22
DID 113A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_H, 3 TARRACO_SEG_AD_MMV_ER_H_3
- Service 22
DID 113B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_L, 0 TARRACO_SEG_AD_MMV_ER_L_0
- Service 22
DID 113E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_L, 2 TARRACO_SEG_AD_MMV_ER_L_2
- Service 22
DID 1140 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_L, 3 TARRACO_SEG_AD_MMV_ER_L_3
- Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_MID, 0 TARRACO_SEG_AD_MMV_ER_MID_0
- Service 22
DID 1132 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_MID, 1 TARRACO_SEG_AD_MMV_ER_MID_1
- Service 22
DID 1133 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER_MID, 2 TARRACO_SEG_AD_MMV_ER_MID_2
- Service 22
DID 1134 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER, 1 TARRACO_SEG_AD_MMV_ER_1
- Service 22
DID 112D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER, 2 TARRACO_SEG_AD_MMV_ER_2
- Service 22
DID 112E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
SEG_AD_MMV_ER, 3 TARRACO_SEG_AD_MMV_ER_3
- Service 22
DID 112F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2018 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2022.
Simulated DPF temperature TARRACO_SIMULATED_DPF_T
- Service 22
DID 3D7F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2018 to 2026.
Spark efficiency deviation at idle, maximum TARRACO_SPARK_EFFICIENCY_DEV_MAX
- Service 22
DID 155B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Spark efficiency deviation at part load, maximum TARRACO_SPARK_EFFICIENCY_DEV_PART_MAX
- Service 22
DID 155C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Stop signal switch TARRACO_MQB_TCM_STOP_SIGNAL_SWITCHConfirmed
- Service 22
DID 3800 - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Tank fill level diagnostic reference value TARRACO_TANK_FILL_LEVEL
- Service 22
DID 51D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2018 to 2026.
TCO_1_ST TARRACO_TCO_1_ST
- Service 22
DID 11D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2018 to 2026.
TCO_1_SYS TARRACO_TCO_1_SYS
- Service 22
DID 11CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2018 to 2026.
Temperature after evaporator TARRACO_CLIMATE_T_AFTER_EVAPConfirmed
- Service 22
DID 2612 - Module
746 → 7B0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -42.624 to 42.291 °C
- Unit
- °C
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Temperature sensor for engine temperature management TARRACO_T_SENS_ENG_T
- Service 22
DID 392A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Temperature sensor for engine temperature management, target value TARRACO_T_SENS_ENG_T_TGT
- Service 22
DID 40E2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
Test of catalytic converter status, canceled TARRACO_TEST_CATALYTIC_CONV_STAT
- Service 22
DID 2927 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Test of catalytic converter, measured value TARRACO_TEST_CATALYTIC_CONV
- Service 22
DID 2926 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535
- Unit
- Number
In testing for 2018 to 2026.
Thermostat, actual TARRACO_THERMOSTAT_ACT
- Service 22
DID 4418 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Thermostat, commanded TARRACO_THERMOSTAT_CMD
- Service 22
DID 4417 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Throttle regulator nominal value TARRACO_THROTTLE_REGULATOR
- Service 22
DID 16C5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
TI_1_MPI, 0 TARRACO_TI_1_MPI_0
- Service 22
DID 13AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_1_MPI, 1 TARRACO_TI_1_MPI_1
- Service 22
DID 13AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_1_MPI, 2 TARRACO_TI_1_MPI_2
- Service 22
DID 13AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_1_MPI, 3 TARRACO_TI_1_MPI_3
- Service 22
DID 13AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_1, 1 TARRACO_TI_MES4_PLS_1_1
- Service 22
DID 13A1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_1, 2 TARRACO_TI_MES4_PLS_1_2
- Service 22
DID 13A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_1, 3 TARRACO_TI_MES4_PLS_1_3
- Service 22
DID 13A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_2, 0 TARRACO_TI_MES4_PLS_2_0
- Service 22
DID 13A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_2, 1 TARRACO_TI_MES4_PLS_2_1
- Service 22
DID 13A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_2, 2 TARRACO_TI_MES4_PLS_2_2
- Service 22
DID 13A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_2, 3 TARRACO_TI_MES4_PLS_2_3
- Service 22
DID 13A7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_3, 0 TARRACO_TI_MES4_PLS_3_0
- Service 22
DID 13A8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_3, 1 TARRACO_TI_MES4_PLS_3_1
- Service 22
DID 13A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_3, 2 TARRACO_TI_MES4_PLS_3_2
- Service 22
DID 13AA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
TI_MES4_PLS_3, 3 TARRACO_TI_MES4_PLS_3_3
- Service 22
DID 13AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2018 to 2026.
Timing deviation after chain replacement, exhaust bank 1 TARRACO_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1
- Service 22
DID 417D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Timing deviation after chain replacement, intake bank 1 TARRACO_TIM_DEV_AFTER_CHAIN_1
- Service 22
DID 417B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Timing deviation after other repairs, intake bank 1 TARRACO_TIM_DEV_AFTER_OTHER_1
- Service 22
DID 417F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Timing deviation after other repairs, intake bank 1 TARRACO_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1
- Service 22
DID 4181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Timing deviation current value exhaust bank 1 TARRACO_TIM_DEV_CURRENT_EXH_1
- Service 22
DID 4185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Timing deviation current value intake bank 1 TARRACO_TIM_DEV_CURRENT_INT_1
- Service 22
DID 4183 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2018 to 2026.
Torque converter: torque loss TARRACO_TORQUE_CONVERTER_TORQUE_LOSS
- Service 22
DID 7053 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque increase request from ESP TARRACO_TQ_INCREASE_REQ_ESP
- Service 22
DID 1340 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque limitation TARRACO_TORQUE_LIMITATION
- Service 22
DID 203F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque limitation TARRACO_TQ_LIM
- Service 22
DID 107D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque limitation TARRACO_TQ_LIM_7E0
- Service 22
DID 203F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque limitation, clutch protection TARRACO_TQ_LIM_CLU
- Service 22
DID 20A0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque loss adaptation TARRACO_TQ_LOSS_ADPT
- Service 22
DID 2122 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque loss adaptation at idle TARRACO_TQ_LOSS_ADPT_IDLE
- Service 22
DID 1225 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque loss adaptation, A/C compressor TARRACO_TQ_LOSS_ADPT_AC_COMP_7E0
- Service 22
DID 1223 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque reduction request from ESP TARRACO_TQ_REDUCTION_REQ_ESP
- Service 22
DID 133F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque request, sum of auxiliary aggregate TARRACO_TQ_REQ_SUM_AUXILIARY
- Service 22
DID 209B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Total mass of gasoline and ethyl alcohol in oil TARRACO_TOT_MASS_GASOLINE
- Service 22
DID 1713 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1398.0581
- Unit
- Raw value
In testing for 2018 to 2026.
Transmission fluid temperature, calculated TARRACO_ATF_T_CALCULATED
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 704E - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2018 to 2026.
Transmission fluid temperature, modeled maximum reached TARRACO_ATF_T_MODELED_MAX_REACHED
- Service 22
DID 7051 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -55 to 200 °C
- Unit
- °C
In testing for 2018 to 2026.
Upper adapted coupling point K1 from macro slip path adaptation TARRACO_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPTConfirmed
- Service 22
DID 110B - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
0xB8 = 184 → = 920 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Upper adapted coupling point K2 from macro slip path adaptation TARRACO_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPTConfirmed
- Service 22
DID 110C - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
0xA9 = 169 → = 845 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Valve lift system, result of last switch, intake TARRACO_VLV_LIFT_SYSTEM
- Service 22
DID 16BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Valve lift system, valve lift, exhaust TARRACO_VLV_LIFT_SYSTEM_VLV_LIFT
- Service 22
DID 16BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Valve lift system, valve lift, intake TARRACO_VLV_LIFT_SYSTEM_VLV
- Service 22
DID 16BA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Valve timing, the difference between the, actual and the set angle TARRACO_VLV_TIM_DIFF_ACT_SET
- Service 22
DID 10EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °
- Unit
- °
In testing for 2018 to 2026.
Variable valve timing, intake, bank 1, regulation TARRACO_VARIABLE_VLV_TIM_INT_1
- Service 22
DID 127B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Variable valve timing, intake, bank 1, switch on TARRACO_VARIABLE_VLV_TIM_INT_1_ON
- Service 22
DID 127D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Wear index %, 0=new engine TARRACO_WEAR_INDEX_0_NEW_ENG
- Service 22
DID 20C2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
DPF
Soot mass calculated TARRACO_PQ35_SOOT_MASS_CALCConfirmed
- Service 22
DID 114F - Module
7E0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Raw value
0x0E3F = 3647 → = 36.47
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2022.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2022.
Fluids
Oil level, critical TARRACO_OIL_CRITConfirmed
- Service 22
DID 11BB - Module
7E0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 26.2 cm
- Unit
- cm
0x2F00 = 12032 → = 4.8128 cm
Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.
Fuel
Activation of fuel pump electronics TARRACO_ACTIVATION_FUEL_PMP
- Service 22
DID 2028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L/h
- Unit
- L/h
Confirmed for 2022. Supported for 2021.
Fuel consumption TARRACO_FUEL_CONSConfirmed
- Service 22
DID 113F - Module
7E0 → 7E8 - Every
30 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
0x0000 = 0 → = 0 L
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Fuel consumption - actual drive cycle TARRACO_FUEL_CONS_ACT_DRIVE
- Service 22
DID 1519 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2018 to 2026.
Fuel consumption per driving cycle TARRACO_FUEL_CONS_PER
- Service 22
DID 51D6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2018 to 2026.
Fuel consumption since last DPF regeneration TARRACO_FUEL_CONS_SINCE_DPF
- Service 22
DID 20D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2018 to 2026.
Fuel high pressure, actual value TARRACO_FUEL_HIGH_P_ACT
- Service 22
DID 2027 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 2018 to 2026.
Fuel high pressure, control deviation TARRACO_FUEL_HIGH_P_CTRL_DEV
- Service 22
DID 20BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 bar
- Unit
- bar
In testing for 2018 to 2026.
Fuel high pressure, specified value TARRACO_FUEL_HIGH_P_SPEC
- Service 22
DID 293B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 2018 to 2026.
Fuel level input % TARRACO_FLI_INPUT
Pelican can show this parameter as the fuel tank level.
- Service 22
DID F42F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Fuel level input, v1 TARRACO_FUEL_LEVEL_INPUT_V1Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 14B4 - Module
7E0 → 7E8 - Every
30 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
0x0384 = 900 → = 9 L
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Fuel low pressure, actual value TARRACO_FUEL_LOW_P_ACT
- Service 22
DID 2025 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2018 to 2026.
Fuel low pressure, specified value TARRACO_FUEL_LOW_P_SPEC
- Service 22
DID 2932 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2018 to 2026.
Fuel metering valve TARRACO_FUEL_METERING_VLV
- Service 22
DID 209A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Fuel mix correction coefficient TARRACO_FUEL_MIX_CORR
- Service 22
DID 1710 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to -73.1003
- Unit
- Number
In testing for 2018 to 2026.
Fuel part from EVAP system TARRACO_FUEL_PART_EVAP
- Service 22
DID 1137 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -0.9996 to 0.9918
- Unit
- Number
In testing for 2018 to 2026.
Fuel pump adaptation TARRACO_FUEL_PMP_ADPT
- Service 22
DID 11C9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Fuel pump, commanded duty TARRACO_FUEL_PMP_CMD_DUTY
- Service 22
DID 11A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 99.998 %
- Unit
- %
In testing for 2018 to 2026.
Fuel rate TARRACO_FUEL_RATE
- Service 22
DID 204C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2018 to 2026.
Fuel rate difference, injector/sensor TARRACO_FUEL_RATE_DIFF_INJ
- Service 22
DID 180A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -127.9983 to 127.9944 L
- Unit
- L
In testing for 2018 to 2026.
Fuel tank fill level TARRACO_FUEL_TANK_FILL_LEVEL
- Service 22
DID 24FC - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2018 to 2026.
Fuel temperature TARRACO_FUEL_T
- Service 22
DID 128A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2018 to 2026.
Fuel temperature TARRACO_FUEL_T_7E0
- Service 22
DID 203E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2018 to 2026.
High fuel pressure, actual TARRACO_HIGH_FUEL_P_ACT
- Service 22
DID 159F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.7675
- Unit
- Raw value
In testing for 2018 to 2026.
High fuel pressure, actual value TARRACO_HIGH_FUEL_P_ACT_7E0
- Service 22
DID 4460 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 2018 to 2026.
High fuel pressure, commanded TARRACO_HIGH_FUEL_P_CMD
- Service 22
DID 11D7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.7675
- Unit
- Raw value
In testing for 2018 to 2026.
High fuel pressure, regulation error TARRACO_HIGH_FUEL_P
- Service 22
DID 11D5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16.384 to 16.3835
- Unit
- Raw value
In testing for 2018 to 2026.
Long term fuel trim bank 1 TARRACO_LONG_TERM_FUEL_TRIM_1
- Service 22
DID F407 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2187 %
- Unit
- %
In testing for 2018 to 2026.
Long term fuel trim direct injection at load TARRACO_LONG_TERM_FUEL_TRIM
- Service 22
DID 1779 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.9999
- Unit
- Number
In testing for 2018 to 2026.
Long term fuel trim port injection at load TARRACO_LONG_TERM_FUEL_TRIM_PORT
- Service 22
DID 177B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.9999
- Unit
- Number
In testing for 2018 to 2026.
Low fuel pressure, actual TARRACO_LOW_FUEL_P_ACT
- Service 22
DID 11C8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Low fuel pressure, commanded TARRACO_LOW_FUEL_P_CMD
- Service 22
DID 11CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 kPa
- Unit
- kPa
In testing for 2018 to 2026.
Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual TARRACO_RAT_EVAPORATED_FUEL_ACT
- Service 22
DID 1711 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.9915
- Unit
- Number
In testing for 2018 to 2026.
Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum TARRACO_RAT_EVAPORATED_FUEL_MAX
- Service 22
DID 1712 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.992
- Unit
- Number
In testing for 2018 to 2026.
Short term fuel trim bank 1 TARRACO_SHORT_TERM_FUEL_TRIM_1
- Service 22
DID F406 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2187 %
- Unit
- %
In testing for 2018 to 2026.
GPS
Satellites, tracked TARRACO_GPS_SATS_TRACKEDConfirmed
- Service 22
DID 2431 - Module
767 → 7D1 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x10 = 16 → 16
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Satellites, visible TARRACO_GPS_SATS_VISIBLEConfirmed
- Service 22
DID 2431 - Module
767 → 7D1 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x04 = 4 → 4
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Movement
A/C compressor speed TARRACO_CLIMATE_A_C_COMP_SPDConfirmed
- Service 22
DID 2603 - Module
746 → 7B0 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
0x00 = 0 → = 0 rpm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Acceleration TARRACO_ACCELERATION_29BIT
- Service 22
DID 12B0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Accelerator pedal position TARRACO_ACCEL_PEDAL_POS
- Service 22
DID 3804 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Accelerator pedal position 1 TARRACO_ACCEL_PEDAL_POS_1
- Service 22
DID F449 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Accelerator pedal position 2 TARRACO_ACCEL_PEDAL_POS_2
- Service 22
DID F44A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Accelerator pedal sensor 1 TARRACO_PQ35_ACCEL_PED_1Confirmed
- Service 22
DID 1221 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
0xFFB8 = -72 → = -14.4 mV
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Accelerator pedal torque limit TARRACO_ACCEL_PEDAL_TQ_LIM
- Service 22
DID 1059 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Camshaft speed TARRACO_CAMSHAFT_VSS
- Service 22
DID 1124 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Compressor speed TARRACO_COMP_SPD
- Service 22
DID 46E1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Crankshaft speed TARRACO_CRANKSHAFT_VSS
Pelican can show this parameter as the engine speed.
- Service 22
DID 16F3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Crankshaft speed, RPM TARRACO_CRANK_SPD_RPM
- Service 22
DID 206E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Diesel particulate filter exhaust speed TARRACO_DPF_EXH_SPD
- Service 22
DID 44F9 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34
- Unit
- Raw value
In testing for 2018 to 2026.
Engine RPM TARRACO_RPM
- Service 22
DID F40C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Engine RPM at idle required TARRACO_ENGINE_RPM_AT_IDLE_REQUIRED
- Service 22
DID 1161 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Front left wheel speed TARRACO_TIRE_FL_SPD_V3
- Service 22
DID 1002 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021 to 2022.
Front right wheel speed TARRACO_TIRE_FR_SPD_V3Confirmed
- Service 22
DID 1001 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2020, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Idle speed specified rpm TARRACO_IDLE_SPD_SPEC_RPM
- Service 22
DID 4056 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Input shaft speed 1 TARRACO_INPUT_SHFT_SPD_1
- Service 22
DID 70E0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32769 to 7000 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Input shaft speed 2 TARRACO_INPUT_SHFT_SPD_2
- Service 22
DID 70E1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32769 to 7000 rpm
- Unit
- rpm
In testing for 2018 to 2026.
Lateral acceleration TARRACO_LATERAL_ACCEL
- Service 22
DID 1644 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Longitudinal acceleration TARRACO_LONGITUDINAL_ACCEL
- Service 22
DID 1633 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Longitudinal acceleration, raw TARRACO_LONGTITUDINAL_ACCELERATION_RAW_VALUE
- Service 22
DID 15CF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Misfires/1000 rpm, cylinder 1 TARRACO_MISFIRES_1000_RPM_C1
- Service 22
DID 291D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires/1000 rpm, cylinder 2 TARRACO_MISFIRES_1000_RPM_C2
- Service 22
DID 2920 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires/1000 rpm, cylinder 3 TARRACO_MISFIRES_1000_RPM_C3
- Service 22
DID 291E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Misfires/1000 rpm, cylinder 4 TARRACO_MISFIRES_1000_RPM_C4
- Service 22
DID 291F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2018 to 2026.
Mixture adaptation factor at idle speed TARRACO_MIXTURE_ADPT_FACTOR_IDLE
- Service 22
DID 3997 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Rear left wheel speed TARRACO_TIRE_RL_SPD_V3Confirmed
- Service 22
DID 1004 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Rear right wheel speed TARRACO_TIRE_RR_SPD_V3
- Service 22
DID 1003 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021 to 2022.
Specified idle RPM TARRACO_MQB_DQ250_SPECIFIED_IDLE_RPMConfirmed
- Service 22
DID 3871 - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
0x0258 = 600 → 600 rpm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Speed output TARRACO_MQB_DQ250_SPD_OUTPUTConfirmed
- Service 22
DID 1009 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
0x0158 = 344 → 344 rpm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Transmission input shaft speed TARRACO_PQ35_TRANS_IN_SPDConfirmed
- Service 22
DID 11F1 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
0x0CD2 = 3282 → = 1,641 rpm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Transmission input speed TARRACO_MQB_TCM_TRANSMISSION_INPUT_SPD_7E1_380AConfirmed
- Service 22
DID 380A - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x051E = 1310 → 1,310 rpm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Transmission output speed TARRACO_MQB_TCM_TRANSMISSION_OUTPUT_SPD_7E1_380BConfirmed
- Service 22
DID 380B - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x0143 = 323 → 323 rpm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Vehicle lateral acceleration, raw value TARRACO_VEHICLE_LATERAL_ACCELERATION_RAW_VALUE
- Service 22
DID 15D1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 g
- Unit
- g
In testing for 2018 to 2026.
Vehicle speed TARRACO_VSSConfirmed
Current vehicle speed.
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
7E0 → 7E8 - Every
250 ms - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Vehicle speed from transmission TARRACO_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSIONConfirmed
Pelican can show this parameter as the speed.
- Service 22
DID 100A - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 3276.7 km/h
- Unit
- km/h
0x0216 = 534 → = 53.4 km/h
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Yaw acceleration, raw value TARRACO_YAW_ACCEL_RAW
- Service 22
DID 15D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2018 to 2026.
Stats
Crashes, driver side TARRACO_CRASH_DRVRConfirmed
- Service 22
DID 2354 - Module
715 → 77F - Every
1 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Crashes, front TARRACO_CRASH_FRONTConfirmed
- Service 22
DID 2353 - Module
715 → 77F - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.
Crashes, passenger side TARRACO_CRASH_PASSConfirmed
- Service 22
DID 2355 - Module
715 → 77F - Every
1 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Crashes, rear TARRACO_CRASH_REARConfirmed
- Service 22
DID 2356 - Module
715 → 77F - Every
1 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Rollovers TARRACO_ROLLOVERConfirmed
- Service 22
DID 2357 - Module
715 → 77F - Every
1 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Tires
Steering wheel angle TARRACO_MQB_SWAConfirmed
- Service 22
DID 1812 - Module
712 → 77C - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -4095.94 to 4095.935 °
- Unit
- °
0x1768 = 5992 → = 749.06 °
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Steering wheel temperature TARRACO_STEER_WHL_T
- Service 22
DID 5505 - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2018 to 2026.
Steering wheel torque sensor 1 TARRACO_STEER_WHL_TQ_SENS_1
- Service 22
DID 1805 - Module
712 → 77C - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -143.9553 to 144.0709 °
- Unit
- °
In testing for 2018 to 2026.
Steering wheel torque sensor 2 TARRACO_STEER_WHL_TQ_SENS_2
- Service 22
DID 1806 - Module
712 → 77C - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -143.9553 to 144.0709 °
- Unit
- °
In testing for 2018 to 2026.
Transmission
Actual position of gear positioner A TARRACO_MQB_DQ250_ACUTAL_POS_GEAR_POSER_AConfirmed
- Service 22
DID 3852 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Actual position of gear positioner B TARRACO_MQB_DQ250_ACUTAL_POS_GEAR_POSER_BConfirmed
- Service 22
DID 385A - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
0x0357 = 855 → = 8.55 mm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Actual position of gear positioner C TARRACO_MQB_DQ250_ACUTAL_POS_GEAR_POSER_CConfirmed
- Service 22
DID 3862 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
0x0357 = 855 → = 8.55 mm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Actual position of gear positioner D TARRACO_MQB_DQ250_ACUTAL_POS_GEAR_POSER_DConfirmed
- Service 22
DID 386A - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
0x0008 = 8 → = 0.08 mm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch 1 actual pressure TARRACO_PQ35_CLUTCH_1_ACTUAL_PConfirmed
- Service 22
DID 38EB - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
0x0000 = 0 → = 0 bar
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch 1 actual pressure raw value TARRACO_PQ35_DL382_CLUTCH_1_ACTUAL_P_RAW_VALUEConfirmed
- Service 22
DID 10F9 - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
0x34 = 52 → = 4.2 bar
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch 1 failed adaptations counter TARRACO_PQ35_CLUTCH_1_FAILED_ADAPTS_COUNTERConfirmed
- Service 22
DID 10CC - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch 1 successful adaptations counter TARRACO_PQ35_CLUTCH_1_SUCCESSFUL_ADAPTS_COUNTERConfirmed
- Service 22
DID 10C9 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x1B6F = 7023 → 7,023
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch 1 valve current: actual TARRACO_MQB_DQ250_CLUTCH_1_VALVE_I_ACTUALConfirmed
- Service 22
DID 3835 - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3276 to 3276.7 mA
- Unit
- mA
0x1321 = 4897 → = 489.7 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch 1 valve current: specified TARRACO_MQB_DQ250_CLUTCH_1_VALVE_I_SPECIFIEDConfirmed
- Service 22
DID 3834 - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3276 to 3276.7 mA
- Unit
- mA
0x1304 = 4868 → = 486.8 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch 2 actual pressure TARRACO_PQ35_CLUTCH_2_ACTUAL_PConfirmed
- Service 22
DID 38EA - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
0x0007 = 7 → = 0.07 bar
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch 2 failed adaptations counter TARRACO_PQ35_CLUTCH_2_FAILED_ADAPTS_COUNTERConfirmed
- Service 22
DID 10ED - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch 2 successful adaptations counter TARRACO_PQ35_CLUTCH_2_SUCCESSFUL_ADAPTS_COUNTERConfirmed
- Service 22
DID 10EA - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x1643 = 5699 → 5,699
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch 2 valve current: actual TARRACO_MQB_DQ250_CLUTCH_2_VALVE_I_ACTUALConfirmed
- Service 22
DID 383E - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 3276.7 mA
- Unit
- mA
0x130F = 4879 → = 487.9 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch 2 valve current: specified TARRACO_MQB_DQ250_CLUTCH_2_VALVE_I_SPECIFIEDConfirmed
- Service 22
DID 383D - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 3276.7 mA
- Unit
- mA
0x1544 = 5444 → = 544.4 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch adaptation values initial kill point 0 for K1 TARRACO_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K1Confirmed
- Service 22
DID 1156 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
0x31 = 49 → = 245 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch adaptation values initial kill point 0 for K2 TARRACO_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K2Confirmed
- Service 22
DID 1157 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
0x2E = 46 → = 230 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch adaptation values lower current point adaptation K1 TARRACO_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K1Confirmed
- Service 22
DID 1158 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
0x2E = 46 → = 230 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Clutch adaptation values lower current point adaptation K2 TARRACO_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K2Confirmed
- Service 22
DID 1159 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
0x2D = 45 → = 225 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Correction values for main press adaptation: high press on clutch 1 TARRACO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_1Confirmed
- Service 22
DID 1181 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
0x0050 = 80 → = 0.8 bar
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Correction values for main press adaptation: low press on clutch 1 TARRACO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_1Confirmed
- Service 22
DID 1180 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
0x0046 = 70 → = 0.7 bar
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Correction values for main pressure adaptation high pressure on clutch 2 TARRACO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_2Confirmed
- Service 22
DID 1183 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
0x003F = 63 → = 0.63 bar
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Correction values for main pressure adaptation low pressure on clutch 2 TARRACO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_2Confirmed
- Service 22
DID 1182 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
0x0041 = 65 → = 0.65 bar
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Current gear TARRACO_CURRENT_GEAR
- Service 22
DID 3EDE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2018 to 2026.
Current gear TARRACO_MQB_TCM_I_GEAR_DQ200Confirmed
- Service 22
DID 3816 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -2 to 253
- Unit
- Number
0x05 = 5 → = 3
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Current lower pressure point clutch 1 from current to pressure adaptation TARRACO_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPTConfirmed
- Service 22
DID 1130 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
0x2E = 46 → = 230 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Current lower pressure point clutch 2 from current to pressure adaptation TARRACO_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPTConfirmed
- Service 22
DID 1132 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
0x2D = 45 → = 225 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Current upper pressure point clutch 1 from current to pressure adaptation TARRACO_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPTConfirmed
- Service 22
DID 1131 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
0xC8 = 200 → = 1,000 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Current upper pressure point clutch 2 from current to pressure adaptation TARRACO_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPTConfirmed
- Service 22
DID 1133 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
0xC8 = 200 → = 1,000 mA
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Driving strategy mountain factor TARRACO_PQ35_DRIVING_STRATEGY_MOUNTAIN_FACTORConfirmed
- Service 22
DID 1018 - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Driving strategy sport factor TARRACO_PQ35_DRIVING_STRATEGY_SPORT_FACTORConfirmed
- Service 22
DID 1019 - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engaged position side A gear selector 1-3 TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_1_3Confirmed
- Service 22
DID 1138 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engaged position side A gear selector 2-4 TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_2_4Confirmed
- Service 22
DID 1139 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engaged position side A gear selector 5 and neutral TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_5_NConfirmed
- Service 22
DID 113A - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engaged position side A gear selector 6 and reverse TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_6_RConfirmed
- Service 22
DID 113B - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engaged position side B gear selector 1-3 TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_1_3Confirmed
- Service 22
DID 1144 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engaged position side B gear selector 2-4 TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_2_4Confirmed
- Service 22
DID 1145 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engaged position side B gear selector 5 and neutral TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_5_NConfirmed
- Service 22
DID 1146 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engaged position side B gear selector 6 and reverse TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_6_RConfirmed
- Service 22
DID 1147 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Engine specified torque during transmission intervention TARRACO_ENG_SPEC_TQ_DURING
- Service 22
DID 2110 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Gear TARRACO_GEAR_V2Confirmed
- Service 22
DID 14CB - Module
7E0 → 7E8 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x04 = 4 → 4
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Gear selector synchronous position G1 TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G1Confirmed
- Service 22
DID 1179 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
0x159F = 5535 → = 55.35 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Gear selector synchronous position G2 TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G2Confirmed
- Service 22
DID 117A - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
0x11EE = 4590 → = 45.9 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Gear selector synchronous position G3 TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G3Confirmed
- Service 22
DID 117B - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
0x1215 = 4629 → = 46.29 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Gear selector synchronous position G4 TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G4Confirmed
- Service 22
DID 117C - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
0x155B = 5467 → = 54.67 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Gear selector synchronous position G5 TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G5Confirmed
- Service 22
DID 117D - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
0x1542 = 5442 → = 54.42 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Gear selector synchronous position G6 TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G6Confirmed
- Service 22
DID 117E - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
0x1548 = 5448 → = 54.48 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Gear selector synchronous position, reverse TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G_RConfirmed
- Service 22
DID 117F - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
0x11E2 = 4578 → = 45.78 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Input shaft 1 TARRACO_MQB_INPUT_SHAFT_1Confirmed
- Service 22
DID 380C - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
0x051A = 1306 → 1,306 rpm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Input shaft 2 TARRACO_MQB_INPUT_SHAFT_2Confirmed
- Service 22
DID 380D - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
0x054F = 1359 → 1,359 rpm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Lower adapted coupling point clutch 1 from kiss point adaptation TARRACO_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_KISS_POINT_ADAPTConfirmed
- Service 22
DID 388D - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
0x31 = 49 → = 0.245 A
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Lower adapted coupling point clutch 2 from kiss point adaptation TARRACO_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_KISS_POINT_ADAPTConfirmed
- Service 22
DID 388E - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
0x2E = 46 → = 0.23 A
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Neutral position gear selector 1-3 TARRACO_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_1_3Confirmed
- Service 22
DID 1140 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x1397 = 5015 → = 50.15 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Neutral position gear selector 2-4 TARRACO_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_2_4Confirmed
- Service 22
DID 1141 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x1382 = 4994 → = 49.94 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Neutral position gear selector 5 and neutral TARRACO_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_5_NConfirmed
- Service 22
DID 1142 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x1371 = 4977 → = 49.77 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Neutral position gear selector 6 and reverse TARRACO_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_6_RConfirmed
- Service 22
DID 1143 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x13A2 = 5026 → = 50.26 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Output shaft 1 TARRACO_MQB_OUTPUT_SHAFT_1Confirmed
- Service 22
DID 380E - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
0x015E = 350 → 350 rpm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Output shaft 2 TARRACO_MQB_OUTPUT_SHAFT_2Confirmed
- Service 22
DID 380F - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
0x4E01 = 19969 → 19,969 rpm
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Powertrain overall gear ratio TARRACO_POWERTRAIN_OVERALL
- Service 22
DID 11DF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Number
In testing for 2018 to 2026.
Road resistance TARRACO_PQ35_ROAD_RESISTANCEConfirmed
- Service 22
DID 1017 - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -31 to 31.894 %
- Unit
- %
0x7F = 127 → = 0.023 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Selected gear TARRACO_SELECTED_GEAR
- Service 22
DID 7050 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -2 to 253 °C
- Unit
- °C
In testing for 2018 to 2026.
Specified torque clutch 1 TARRACO_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_1Confirmed
- Service 22
DID 382E - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1638.35 N·m
- Unit
- N·m
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Specified torque clutch 2 TARRACO_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_2Confirmed
- Service 22
DID 3838 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638 to 1638.35 N·m
- Unit
- N·m
0xD120 = -12000 → = -600 N·m
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Synchronous position side A gear selector 1-3 TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_1_3Confirmed
- Service 22
DID 113C - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x1215 = 4629 → = 46.29 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Synchronous position side A gear selector 2-4 TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_2_4Confirmed
- Service 22
DID 113D - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x11EE = 4590 → = 45.9 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Synchronous position side A gear selector 5 and neutral TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_5_NConfirmed
- Service 22
DID 113E - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x1344 = 4932 → = 49.32 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Synchronous position side A gear selector 6 and reverse TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_6_RConfirmed
- Service 22
DID 113F - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x11E2 = 4578 → = 45.78 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Synchronous position side B gear selector 1-3 TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_1_3Confirmed
- Service 22
DID 1148 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x159F = 5535 → = 55.35 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Synchronous position side B gear selector 2-4 TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_2_4Confirmed
- Service 22
DID 1149 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x155B = 5467 → = 54.67 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Synchronous position side B gear selector 5 and neutral TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_5_NConfirmed
- Service 22
DID 114A - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x1542 = 5442 → = 54.42 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Synchronous position side B gear selector 6 and reverse TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_6_RConfirmed
- Service 22
DID 114B - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
0x1548 = 5448 → = 54.48 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Torque loss adaptation, A/C compressor + gear engaged TARRACO_TQ_LOSS_ADPT_AC_COMP
- Service 22
DID 1222 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Torque loss adaptation, gear engaged TARRACO_TQ_LOSS_ADPT_GEAR
- Service 22
DID 1224 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2018 to 2026.
Transmission coolant valve, open TARRACO_TRANS_CLT_VLV_OPEN
- Service 22
DID 3D74 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2018 to 2026.
Transmission gear ratio TARRACO_TRANS_GEAR_RAT
- Service 22
DID 0327 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1.28 to 1.27
- Unit
- Number
In testing for 2018 to 2026.
Upper adapted coupling point clutch 1 from microslip adaptation TARRACO_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_MICROSLIP_ADAPTConfirmed
- Service 22
DID 388F - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
0xB8 = 184 → = 0.92 A
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Upper adapted coupling point clutch 2 from microslip adaptation TARRACO_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_MICROSLIP_ADAPTConfirmed
- Service 22
DID 3890 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
0xA9 = 169 → = 0.845 A
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Trips
Analysis, clutch 1 temperature time in range 1 TARRACO_ANALYSIS_CLU_1_T_1
- Service 22
DID 1066 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Analysis, clutch 1 temperature time in range 2 TARRACO_ANALYSIS_CLU_1_T_2
- Service 22
DID 1067 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Analysis, clutch 1 temperature time in range 3 TARRACO_ANALYSIS_CLU_1_T_3
- Service 22
DID 1068 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Analysis, clutch 2 temperature time in range 0 TARRACO_ANALYSIS_CLU_2_T_0
- Service 22
DID 107A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Analysis, clutch 2 temperature time in range 1 TARRACO_ANALYSIS_CLU_2_T_1
- Service 22
DID 107B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Analysis, clutch 2 temperature time in range 2 TARRACO_ANALYSIS_CLU_2_T_2
- Service 22
DID 107C - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Analysis, clutch 2 temperature time in range 3 TARRACO_ANALYSIS_CLU_2_T_3
- Service 22
DID 107D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Clutch 1 temperature time in range 0 TARRACO_CLU_1_T_TIME_RANGE_0
- Service 22
DID 1065 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2018 to 2026.
Distance to empty TARRACO_DTE
Pelican can show this parameter as the fuel range.
- Service 22
DID 2294 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021 to 2022.
Drive cycles counter TARRACO_MQB_TCM_DRIVE_CYCLES_COUNTERConfirmed
- Service 22
DID 388B - Module
7E1 → 7E9 - Every
3600 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x07E6 = 2022 → 2,022
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Driving time ecological TARRACO_MQB_TCM_DRIVING_TIME_ECOLOGICALConfirmed
- Service 22
DID 3888 - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x22 = 34 → 34 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Driving time manual TARRACO_MQB_TCM_DRIVING_TIME_MANUALConfirmed
- Service 22
DID 388A - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x04 = 4 → 4 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Driving time sporty TARRACO_MQB_TCM_DRIVING_TIME_SPORTYConfirmed
- Service 22
DID 3889 - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → 0 %
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Gasoline particulate filter distance since last regeneration TARRACO_GPF_DIST_SINCE_REGEN
- Service 22
DID 208D - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2018 to 2026.
Ignition cycles TARRACO_MQB_TCM_IGNITION_CYCLESConfirmed
- Service 22
DID 388C - Module
7E1 → 7E9 - Every
1 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x1CFE = 7422 → 7,422
Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.
Mixture variation in adapted part load range 1 TARRACO_MIXTURE_VARIATION_1
- Service 22
DID 39BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2018 to 2026.
Odometer TARRACO_MQB_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID 2A0A - Module
710 → 77A - Every
5 s - Testing for 2018 to 2020, 2023 to 2026
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777175 km
- Unit
- km
In testing for 2018 to 2020, 2023 to 2026. Supported for 2021 to 2022.
Odometer TARRACO_MQB_TCM_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 3841 - Module
7E1 - Every
30 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
0x069B0900 = 110823680 → = 11,082,368 km
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Odometer TARRACO_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 10E0 - Module
7E0 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
0x0000F70F = 63247 → 63,247 km
Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.
Odometer TARRACO_ODO_ECMConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 295A - Module
7E0 - Every
30 s - Testing for 2018 to 2020, 2022 to 2026
Example reply from a 2021 Seat Tarraco.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x0001EE = 494 → 494 km
Confirmed for 2021. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2022.
Odometer #2 TARRACO_MQB_TCM_ODO_2Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 3887 - Module
7E1 - Every
30 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
0x000ADE00 = 712192 → = 71,219.2 km
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Odometer #3 TARRACO_PQ35_ODO_3Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 101A - Module
7E1 - Every
30 s - Testing for 2018 to 2020, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x0FF700 = 1046272 → 1,046,272 km
Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.
Odometer with ECU installed TARRACO_ODO_ECU_INSTALLED
- Service 22
DID 295B - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 m
- Unit
- m
In testing for 2018 to 2026.
Odometer, high resolution TARRACO_ODO_HDConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 1160 - Module
7E0 → 7E8 - Every
5 s - Testing for 2018 to 2021, 2023 to 2026
Example reply from a 2022 Seat Tarraco.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 m
- Unit
- m
0x03C269B2 = 63072690 → 63,072,690 m
Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.
Odometer, mileage, HR TARRACO_ODO_MILEAGE_HR
- Service 22
DID 22B8 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2018 to 2026.
Operating time, temperature range 1 TARRACO_OP_TIME_T_RANGE_1
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2018 to 2026.
Operating time, temperature range 2 TARRACO_OP_TIME_T_RANGE_2
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2018 to 2026.
Operating time, temperature range 3 TARRACO_OP_TIME_T_RANGE_3
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2018 to 2026.
Operating time, temperature range 4 TARRACO_OP_TIME_T_RANGE_4
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2018 to 2026.
Operating time, temperature range 5 TARRACO_OP_TIME_T_RANGE_5
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2018 to 2026.
Operating time, temperature range 6 TARRACO_OP_TIME_T_RANGE_6
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2018 to 2026.