Seat Tarraco

Parameters

The Seat Tarraco has 667 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage TARRACO_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x1EA6 = 7846 → 78461000+4 = 11.846 V

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery capacity TARRACO_12V_BAT_CAP

  • Service 22DID 2A06
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2018 to 2026.

Accelerator pedal, sensor 1 voltage TARRACO_ACCEL_PEDAL_SENS_1_V

  • Service 22DID 102A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2018 to 2026.

Accelerator pedal, sensor 2 voltage TARRACO_ACCEL_PEDAL_SENS_2_V

  • Service 22DID 102B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2018 to 2026.

Battery charge level TARRACO_BAT_SOCConfirmed

  • Service 22DID 2A0C
  • Module710 → 77A
  • Every10 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x43 = 67 → 67 %

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Battery current TARRACO_BAT_IConfirmed

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-2147483.648 to 2147483 A
Unit
A

0x00000000 = 0 → 01000 = 0 A

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Battery internal resistance TARRACO_BAT_INT_RConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×20100
Range
0 to 51
Unit
Raw value

0x1F = 31 → 31×20100 = 6.2

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Battery internal resistance, raw TARRACO_BAT_INTERNAL_RES_RAW

  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51
Unit
Raw value

In testing for 2018 to 2026.

Battery sensor temperature TARRACO_MQB_BAT_SEN_TConfirmed

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Battery temperature TARRACO_BAT_TConfirmed

  • Service 22DID 2A0B
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Battery total charge TARRACO_MQB_BAT_TOT_CHGConfirmed

  • Service 22DID 2A61
  • Module710 → 77A
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

0x00000000 = 0 → 010 = 0 Ah

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Battery total discharge TARRACO_MQB_BAT_TOT_DISConfirmed

  • Service 22DID 2A61
  • Module710 → 77A
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

0x00000000 = 0 → 010 = 0 Ah

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Battery voltage TARRACO_BAT_V_2A07Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2A07
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.535 V
Unit
V

0x1EA6 = 7846 → 78461000+4 = 11.846 V

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Battery voltage TARRACO_BATTERY_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 105A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×20
Range
-655360 to 655340 mV
Unit
mV

In testing for 2018 to 2026.

Battery voltage at rest TARRACO_BAT_V_AT_RESTConfirmed

  • Service 22DID 2A10
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+9
Range
9 to 34.5 V
Unit
V

0x21 = 33 → 3310+9 = 12.3 V

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Bypass valve high pressure turbine inlet, raw voltage TARRACO_BYPASS_VLV_HIGH_P_V

  • Service 22DID 3D01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2018 to 2026.

Charge air pressure TARRACO_PQ35_CHG_AIR_PConfirmed

  • Service 22DID 2211
  • Module714 → 77E
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x0D = 13 → 13×100255 = 5.098039 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Charge air pressure actuator, acknowledgment TARRACO_CHG_AIR_P_ACTUATOR

  • Service 22DID 2065
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Charge pressure actuator, actual position TARRACO_CHG_P_ACTUATOR_ACT

  • Service 22DID 39A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.012207
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure actuator, adaptation for lower stop TARRACO_CHG_P_ACTUATOR_ADPT

  • Service 22DID 39A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2018 to 2026.

Charge pressure actuator, adaptation for upper stop TARRACO_CHG_P_ACTUATOR_ADPT_HI

  • Service 22DID 39A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2018 to 2026.

Charge pressure actuator, maximum sensor voltage TARRACO_CHG_P_ACTUATOR_MAX_V

  • Service 22DID 3D77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 mV
Unit
mV

In testing for 2018 to 2026.

Charge pressure actuator, specified position TARRACO_CHG_P_ACTUATOR_SPEC

  • Service 22DID 39A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2018 to 2026.

Charge pressure actuator, specified value TARRACO_CHG_P_ACTUATOR_SPEC_7E0

  • Service 22DID 39A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.012207
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure control adaptation higher than max. threshold TARRACO_CHG_P_CTRL_ADPT_MAX

  • Service 22DID 293E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure control adaptation lower than min. threshold TARRACO_CHG_P_CTRL_ADPT_LO_MIN

  • Service 22DID 293F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure control valve activation pulse duty factor TARRACO_CHG_P_CTRL_VLV

  • Service 22DID 3EA9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure control valve position, actual value TARRACO_CHG_P_CTRL_VLV_POS_ACT

  • Service 22DID 3EA7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure control valve position, target value TARRACO_CHG_P_CTRL_VLV_POS_TGT

  • Service 22DID 3EA6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Charge pressure control valve sensor voltage TARRACO_CHG_P_CTRL_VLV_SENS_V

  • Service 22DID 3EA8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2018 to 2026.

Charge pressure control valve voltage, position closed TARRACO_CHG_P_CTRL_VLV_V_POS

  • Service 22DID 3EAB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2018 to 2026.

Charge pressure control valve voltage, position opened TARRACO_CHG_P_CTRL_VLV_V_POS_OPENED

  • Service 22DID 3EAC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000000
Range
0 to 9.9999 V
Unit
V

In testing for 2018 to 2026.

Charge pressure regulator, lower threshold adaptation TARRACO_CHG_P_REGULATOR_LO

  • Service 22DID 16EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2018 to 2026.

Charge pressure regulator, upper threshold adaptation TARRACO_CHG_P_REGULATOR_HI

  • Service 22DID 16ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

In testing for 2018 to 2026.

Charge pressure sensor, unconditioned voltage TARRACO_CHG_P_SENS_V

  • Service 22DID 29C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Control module voltage TARRACO_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

0x2DB4 = 11700 → 117001000 = 11.7 V

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Cylinder charge specified value TARRACO_CYL_CHG_SPEC

  • Service 22DID 432F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2018 to 2026.

Cylinder charge, actual value TARRACO_CYL_CHG_ACT

  • Service 22DID 4367
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7
Unit
Raw value

In testing for 2018 to 2026.

Diesel particulate filter heat voltage TARRACO_DPF_HEAT_V

  • Service 22DID 44FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 V
Unit
V

In testing for 2018 to 2026.

eCall battery charge level TARRACO_ECALL_SOCConfirmed

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x64 = 100 → 100 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

eCall battery status TARRACO_ECALL_STATUSConfirmed

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x02 = 2 → NORMAL

States
Raw valueState
1CRITICAL
2NORMAL

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Generator target voltage TARRACO_MQB_GEN_TRG_VConfirmed

  • Service 22DID 2A00
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
10.6 to 36.1 V
Unit
V

0x18 = 24 → 2410+10.6 = 13 V

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Generator voltage, actual TARRACO_GEN_V_ACT

  • Service 22DID 4F00
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

In testing for 2018 to 2026.

Knock sensors average voltage bank 1, variant 2 TARRACO_KNOCK_SENSORS_AVG_V_1_2

  • Service 22DID 4E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Maximum charge current TARRACO_MAX_CHA_CUR_2Confirmed

  • Service 22DID 1159
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Maximum discharge current TARRACO_MAX_DCHA_CUR_2Confirmed

  • Service 22DID 1158
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Temperature sensor for engine temperature management voltage TARRACO_T_SENS_ENG_T_V

  • Service 22DID 40E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Turbocharger inlet pressure corrected value TARRACO_TURBOCHARGER_INLET_P

  • Service 22DID 11D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2018 to 2026.

Usable battery charge TARRACO_USE_BAT_CHGConfirmed

  • Service 22DID 2A0F
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

0x1A = 26 → 26 Ah

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Climate

A/C compressor torque, requested TARRACO_AC_COMP_TConfirmed

  • Service 22DID 1002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

0x0000 = 0 → 010 = 0 N·m

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Ambient temperature TARRACO_AAT_V2Confirmed

  • Service 22DID 1004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-255 to 255 °C
Unit
°C

0x0000 = 0 → 0128 = 0 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Cabin humidity TARRACO_CABIN_HUMIDITYConfirmed

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every1 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x54 = 84 → 842 = 42 %

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Outside temperature TARRACO_AATConfirmed

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °C
Unit
°C

0x01 = 1 → 12 = 0.5 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Recirculation flap actual position TARRACO_MQB_RECIRC_FLAP_ACTConfirmed

  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x01AA = 426 → 426

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Recirculation flap fresh air threshold TARRACO_MQB_RECIRC_FLAP_FRESH_THRConfirmed

  • Service 22DID 2620
  • Module746 → 7B0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x00A8 = 168 → 168

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Recirculation flap target position TARRACO_MQB_RECIRC_FLAP_TRGConfirmed

  • Service 22DID 261F
  • Module746 → 7B0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x01AC = 428 → 428

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Recirculation flap threshold TARRACO_MQB_RECIRC_FLAP_THRConfirmed

  • Service 22DID 2621
  • Module746 → 7B0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0353 = 851 → 851

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Windshield temperature TARRACO_WINDSHIELD_TConfirmed

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every1 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.576−38.8
Range
-38.8 to 108.08 °C
Unit
°C

0x01 = 1 → 1×0.576−38.8 = -38.224 °C

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Clocks

Time since engine start TARRACO_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x0000 = 0 → 0 s

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2022. Supported for 2021.

Brake booster low pressure, actual TARRACO_BRAKE_BOOSTER_LOW_P_ACT

  • Service 22DID 1490
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×390631000000
Range
0 to 2559.9937
Unit
Raw value

In testing for 2018 to 2026.

Brake booster raw pressure TARRACO_BRAKE_BOOSTER_RAW_P

  • Service 22DID 11D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Brake pedal position TARRACO_BRAKE_PEDAL_POS

  • Service 22DID 105D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Brake pressure TARRACO_BRAKE_P

  • Service 22DID 2B21
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×15299910000000−42.503
Range
-543.8501 to 458.8288 bar
Unit
bar

In testing for 2018 to 2026.

Hydraulic brake booster: active TARRACO_HYD_BRAKE_BOOST_ACTIVEConfirmed

  • Service 22DID 1810
  • Module713 → 77D
  • Every2 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Pressure in brake servo unit TARRACO_P_BRAKE_SERVO_UNIT

  • Service 22DID 2005
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375
Unit
Raw value

In testing for 2018 to 2026.

Requested brake torque, auxiliary system TARRACO_REQ_BRAKE_TQ

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2018 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared TARRACO_CLR_DISTConfirmed

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x2489 = 9353 → 9,353 km

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Distance traveled while mil was activated TARRACO_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Number of warm-ups since diagnostic trouble codes cleared TARRACO_WARM_UPSConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFF = 255 → 255

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

ECU

Misfires, cylinder 2 TARRACO_MISFIRES__CYL__2Confirmed

  • Service 22DID 1152
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0D83 = 3459 → 3,459

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Misfires, cylinder 4 TARRACO_MISFIRES__CYL__4Confirmed

  • Service 22DID 1151
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0950 = 2384 → 2,384

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engine

A/C clutch TARRACO_CLIMATE_A_C_CLCHConfirmed

  • Service 22DID 482B
  • Module746 → 7B0
  • Every2 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

A/C compressor load TARRACO_CLIMATE_A_C_COMP_LOADConfirmed

  • Service 22DID 2604
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 N·m
Unit
N·m

0x00 = 0 → 010 = 0 N·m

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

A/C compressor torque TARRACO_A_C_COMPRESSOR_TORQUE

  • Service 22DID 101A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

A/C refrigerant pressure TARRACO_A_C_REFRIGERANT_PRES

  • Service 22DID 1017
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2018 to 2026.

Adaptation of throttle valve TARRACO_ADPT_THROTTLE_VLV

  • Service 22DID 292B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Air conditioning compressor pressure, linear raw value TARRACO_AC_COMP_P_LINEAR_RAW

  • Service 22DID 15C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070
Unit
Raw value

In testing for 2018 to 2026.

Air conditioning compressor torque TARRACO_AC_COMP_TQ

  • Service 22DID 2017
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 N·m
Unit
N·m

In testing for 2018 to 2026.

Air conditioning refrigerant pressure TARRACO_AC_REFRIGERANT_P

  • Service 22DID 412A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534
Unit
Raw value

In testing for 2018 to 2026.

Air filling TARRACO_AIR_FILLING

  • Service 22DID 121C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×11719500000
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Air leakage TARRACO_AIR_LEAKAGE

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Air mass, actual value, mg/stroke TARRACO_AIR_MASS_ACT_MG

  • Service 22DID 29D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2026.

Air pollution level TARRACO_CLIMATE_AIR_POLUTION_LVLConfirmed

  • Service 22DID 26ED
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.8 to 12.7
Unit
Number

0x00 = 0 → 010 = 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Ambient air pressure TARRACO_AMBIENT_AIR_P

  • Service 22DID 1509
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×391000
Range
0 to 2555.8649
Unit
Raw value

In testing for 2018 to 2026.

Ambient air temperature TARRACO_DASH_AMBIENT_AIR_TConfirmed

  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x64 = 100 → 1002−50 = 0 °C

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Analysis, clutch 1, maximum temperature TARRACO_ANALYSIS_CLU_1_MAX_T

  • Service 22DID 1064
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2026.

Analysis, clutch 2, maximum temperature TARRACO_ANALYSIS_CLU_2_MAX_T

  • Service 22DID 1079
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2026.

Automatic engine starts counter TARRACO_AUTOMATIC_ENG_STARTS

  • Service 22DID 2999
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Automatic transmission fluid temperature, variant 2 TARRACO_MQB_TCM_ATF_T_VAR_2_DSG_S_TRONICConfirmed

  • Service 22DID 2104
  • Module7E1
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

0x0008 = 8 → 8 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Average ignition timing angle delay adjustment TARRACO_AVG_IGN_TIM_ANG

  • Service 22DID 2949
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Avg. injection time TARRACO_AVG_INJ_TIME

  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val2500
Range
0 to 1717986 ms
Unit
ms

In testing for 2018 to 2026.

Avg. injection time TARRACO_AVG_INJ_TIME_7E0

  • Service 22DID 2003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25 ms
Unit
ms

In testing for 2018 to 2026.

Basic correction factor:, cylinder 1, filtered TARRACO_BASIC_CORR_FACTOR_1

  • Service 22DID 171A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2018 to 2026.

Basic correction factor:, cylinder 2, filtered TARRACO_BASIC_CORR_FACTOR_2

  • Service 22DID 171D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2018 to 2026.

Basic correction factor:, cylinder 3, filtered TARRACO_BASIC_CORR_FACTOR_3

  • Service 22DID 171B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2018 to 2026.

Basic correction factor:, cylinder 4, filtered TARRACO_BASIC_CORR_FACTOR_4

  • Service 22DID 171C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×799965535000
Range
0 to 7.999
Unit
Number

In testing for 2018 to 2026.

Boost pressure actuator, commanded duty TARRACO_BOOST_P_ACTUATOR_CMD

  • Service 22DID 16EE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.0122068184
Range
-399.993 to 100 %
Unit
%

In testing for 2018 to 2026.

Boost pressure commanded TARRACO_PQ35_BOOST_P_CMDConfirmed

  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

0x0000 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Boost pressure, actual TARRACO_BOOST_P_ACT

  • Service 22DID 11F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2018 to 2026.

Boost regulation duty, commanded value TARRACO_BOOST_REGULATION_CMD

  • Service 22DID 1219
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234384354
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Bypass valve high pressure turbine inlet, activation TARRACO_BYPASS_VLV_HIGH_P_TURBINE_INLET

  • Service 22DID 39FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Bypass valve high pressure turbine inlet, actual value TARRACO_BYPASS_VLV_HIGH_P_ACT

  • Service 22DID 39FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×252048
Range
-400 to 100 %
Unit
%

In testing for 2018 to 2026.

Bypass valve high pressure turbine inlet, offset closed TARRACO_BYPASS_VLV_HIGH_P

  • Service 22DID 39FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399.9989 to 100 %
Unit
%

In testing for 2018 to 2026.

Bypass valve high pressure turbine inlet, offset open TARRACO_BYPASS_VLV_HIGH_P_TURBINE

  • Service 22DID 39FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.012207
Range
-399.9989 to 100 %
Unit
%

In testing for 2018 to 2026.

Bypass valve high pressure turbine inlet, target value TARRACO_BYPASS_VLV_HIGH_P_TGT

  • Service 22DID 39FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×252048
Range
-400 to 100 %
Unit
%

In testing for 2018 to 2026.

Cabin temperature TARRACO_CABIN_TConfirmed

  • Service 22DID 2613
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x0002 = 2 → 210 = 0.2 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2022. Supported for 2021.

Camshaft adaptation exhaust bank 1, phase position TARRACO_CAM_ADPT_EXH_BANK_1_PHASE

  • Service 22DID 2023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Camshaft adaptation intake bank 1, phase position TARRACO_CAM_ADPT_INT_BANK_1_PHASE

  • Service 22DID 2021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Camshaft adaptation, counter due to knock TARRACO_CAM_ADPT_CNT_KNOCK

  • Service 22DID 523B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Camshaft adaptation, exhaust bank 1, phase position TARRACO_CAM_ADPT_EXH_BANK_1

  • Service 22DID 1128
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2018 to 2026.

Camshaft adaptation, intake bank 1, phase position TARRACO_CAM_ADPT_INT_BANK_1

  • Service 22DID 1125
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34 °
Unit
°

In testing for 2018 to 2026.

Camshaft adaptation, intake deviation TARRACO_CAM_ADPT_INT_DEV

  • Service 22DID 4FF5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255.9921 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment intake bank 1, activation % TARRACO_CAM_ADJ_INT_BANK_1

  • Service 22DID 2930
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Camshaft adjustment intake test bank 1 TARRACO_CAM_ADJ_INT_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Camshaft adjustment outlet test bank 1 TARRACO_CAM_ADJ_OUTLET_TEST_1

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Camshaft adjustment, exhaust bank 1, actual value TARRACO_CAM_ADJ_EXH_BANK_1_ACT

  • Service 22DID 136C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, exhaust bank 1, specified value TARRACO_CAM_ADJ_EXH_BANK_1_SPEC

  • Service 22DID 1371
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, exhaust, actual value TARRACO_CAM_ADJ_EXH_ACT

  • Service 22DID 201A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, exhaust, specified value TARRACO_CAM_ADJ_EXH_SPEC

  • Service 22DID 2019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, intake bank 1, actual value TARRACO_CAM_ADJ_INT_BANK_1_ACT

  • Service 22DID 136E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, intake bank 1, specified value TARRACO_CAM_ADJ_INT_BANK_1_SPEC

  • Service 22DID 1373
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val125
Range
-262.144 to 262.136 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, intake, actual value TARRACO_CAM_ADJ_INT_ACT

  • Service 22DID 201E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Camshaft adjustment, intake, specified value TARRACO_CAM_ADJ_INT_SPEC

  • Service 22DID 201D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Camshaft end position TARRACO_PQ35_CAMS_ENDConfirmed

  • Service 22DID 1341
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 °
Unit
°

0x0302 = 770 → 7705 = 154 °

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Camshaft position, deviation from the base position TARRACO_CAM_POS_DEV_BASE_POS

  • Service 22DID 1385
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2018 to 2026.

Cat. converter oxygen storage capacity measured TARRACO_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED

  • Service 22DID 1507
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Catalyst temperature, calculated TARRACO_CAT_T_CALC

  • Service 22DID 1515
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5−50
Range
-50 to 1225 °C
Unit
°C

In testing for 2018 to 2026.

Centrifugal oil temperature TARRACO_PQ35_CENTRIFUGAL_OIL_TConfirmed

  • Service 22DID 38B2
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

0x51 = 81 → 81

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Chain elongation inlet, mileage at last adaptation TARRACO_CHAIN_ELONGATION_INLET

  • Service 22DID 516C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2018 to 2026.

Chain elongation outlet, mileage at last adaptation TARRACO_CHAIN_ELONGATION

  • Service 22DID 5149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2018 to 2026.

Chain elongation, no of valid initial values, exhaust bank 1 TARRACO_CHAIN_ELONGATION_NO_VALID_1

  • Service 22DID 4189
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Chain elongation, no of valid initial values, intake bank 1 TARRACO_CHAIN_ELONGATION_NO_1

  • Service 22DID 4187
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Clutch center central plate temperature TARRACO_CLU_CENTER_CENTRAL_T

  • Service 22DID 102A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2018 to 2026.

Commanded crankshaft torque TARRACO_CMD_CRANK_TQ

  • Service 22DID 11E0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2022.

Control module temperature TARRACO_MQB_TCM_ECU_TConfirmed

  • Service 22DID 028D
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x52 = 82 → 82 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Converter loss torque TARRACO_MQB_TCM_CONVERTER_LOSS_TORQUEConfirmed

  • Service 22DID 1010
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x5000 = 20480 → 2048020 = 1,024 N·m

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Coolant circulation pump, activation TARRACO_CLT_CIRCULATION_PMP_ACTIVATION

  • Service 22DID 276D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant circulation pump, control TARRACO_CLT_CIRCULATION_PMP

  • Service 22DID 167E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant fan 1, activation TARRACO_CLT_FAN_1_ACTIVATION

  • Service 22DID 2055
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant fan 1, activation TARRACO_COOLANT_FAN_1_ACTIVATION

  • Service 22DID 1130
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant fan 2, activation TARRACO_CLT_FAN_2_ACTIVATION

  • Service 22DID 2056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant fan, requested by A/C TARRACO_CLT_FAN_REQ_AC

  • Service 22DID 1018
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2018 to 2026.

Coolant shut-off valve, closed TARRACO_CLT_SHUT_OFF_VLV

  • Service 22DID 2682
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2018 to 2026.

Coolant temperature at engine outlet, calculated TARRACO_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED

  • Service 22DID 4490
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at engine start TARRACO_COOLANT_T_AT_ENGINE_START

  • Service 22DID 1291
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at engine start TARRACO_ECT_ENG_START

  • Service 22DID 2935
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at radiator outlet TARRACO_COOLANT_TConfirmed

  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

0x0E63 = 3683 → 368310−273.1 = 95.2 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Coolant temperature at radiator outlet v.1 TARRACO_ECT_RADIATOR_OUTLET_V_1

  • Service 22DID 15CD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at radiator outlet, actual value TARRACO_ECT_RADIATOR_OUTLET_ACT

  • Service 22DID 202B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature at radiator outlet, specified value TARRACO_ECT_RADIATOR_OUTLET_SPEC

  • Service 22DID 202C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature difference between engine and radiator TARRACO_ECT_DIFF_ENG

  • Service 22DID 202E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature linear TARRACO_ECT_LINEAR

  • Service 22DID 1513
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2929710000000−48
Range
-48 to 143.9978 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature modeled value TARRACO_COOLANT_T_MODELED_VALUE

  • Service 22DID 13A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature, maximum value TARRACO_ECT_MAX

  • Service 22DID 1511
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Coolant temperature, minimum value TARRACO_ECT_MIN

  • Service 22DID 1512
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Correction values for main pressure adaptation TARRACO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPTConfirmed

  • Service 22DID 11A7
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0046 = 70 → 70100 = 0.7 bar

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Crankshaft rotation angle when closing the quantity control valve TARRACO_CRANK_ROT_ANG

  • Service 22DID 10EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Critical engine oil level TARRACO_PQ35_OIL_LVL_CRITConfirmed

  • Service 22DID 11BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 mm
Unit
mm

0x0ABC = 2748 → 2748250 = 10.992 mm

Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.

CTR_MIS_DC_MMV_CYL_SAE, 0 TARRACO_CTR_MIS_DC_MMV_CYL_0

  • Service 22DID 148D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 1 TARRACO_CTR_MIS_DC_MMV_CYL_1

  • Service 22DID 148E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

CTR_MIS_DC_MMV_CYL_SAE, 2 TARRACO_CTR_MIS_DC_MMV_CYL_2

  • Service 22DID 148F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Cylinder block temperature sensor TARRACO_CYL_BLOCK_T_SENS

  • Service 22DID 51D4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Cylinder head temperature TARRACO_CYL_HEAD_T

  • Service 22DID 1065
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2018 to 2026.

Diesel particulate filter air pressure sensor raw value TARRACO_DPF_AIR_P_SENS_RAW

  • Service 22DID 4494
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Diesel particulate filter ash load limit TARRACO_DPF_ASH_LOAD_LIM

  • Service 22DID 406B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.9921
Unit
Raw value

In testing for 2018 to 2026.

Diesel particulate filter cleaning deviation reaction time TARRACO_DPF_CLEANING_DEV

  • Service 22DID 44F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767
Unit
Number

In testing for 2018 to 2026.

Diesel particulate filter counter for regeneration time TARRACO_DPF_CNT_REGEN_TIME

  • Service 22DID 39F9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1625
Range
0 to 41942.4 s
Unit
s

In testing for 2018 to 2026.

Diesel particulate filter differential pressure sensor temperature TARRACO_DPF_DIFF_P_SENS_T

  • Service 22DID 43C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×195311000000−50
Range
-689.9918 to 589.9722 °C
Unit
°C

In testing for 2018 to 2026.

Diesel particulate filter differential pressure, dynamic offset TARRACO_MQB_DPF_DIFF_P_DYNAMIC_OFFSETConfirmed

  • Service 22DID 15B8
  • Module7E0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

0x04DF = 1247 → 1,247

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Diesel particulate filter differential pressure, raw value 1 TARRACO_DPF_DIFF_P_RAW_1

  • Service 22DID 43BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Diesel particulate filter differential pressure, raw value 2 TARRACO_DPF_DIFF_P_RAW_2

  • Service 22DID 43BF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2018 to 2026.

Diesel particulate filter exhaust gas flow volume TARRACO_MQB_DPF_EXH_VOLConfirmed

  • Service 22DID 11E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Number

0x003E = 62 → 62×100010000 = 6.2

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Diesel particulate filter exhaust temperature TARRACO_DPF_EXH_T

  • Service 22DID 44F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Diesel particulate filter input temperature raw value TARRACO_DPF_INPUT_T_RAW

  • Service 22DID 449B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Diesel particulate filter output temperature raw value TARRACO_DPF_OUTPUT_T_RAW

  • Service 22DID 449A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Diesel particulate filter regeneration level current TARRACO_DPF_REGEN_LEVEL

  • Service 22DID 080D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Diesel particulate filter regeneration request status TARRACO_DPF_REGEN_REQ_STAT

  • Service 22DID 2087
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Diesel particulate filter regeneration status TARRACO_DPF_REGEN_STAT

  • Service 22DID 0809
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Diesel particulate filter regeneration, cancel conditions TARRACO_DPF_REGEN_CANCEL

  • Service 22DID 29F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Diesel particulate filter soot measured TARRACO_DPF_SOOT_MEAS

  • Service 22DID 208C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2018 to 2026.

Diesel particulate filter surface temperature TARRACO_DPF_SURFACE_T

  • Service 22DID 44FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16−273.15
Range
-2321.15 to 1774.7875 °C
Unit
°C

In testing for 2018 to 2026.

Diesel particulate filter time since last regeneration TARRACO_DPF_TIME_SINCE_REGEN

  • Service 22DID 2089
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1953110000000
Range
0 to 127.9964 h
Unit
h

In testing for 2018 to 2026.

Driver demand torque TARRACO_MQB_TCM_DRIVER_DEMAND_TORQUEConfirmed

  • Service 22DID 100B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x5C03 = 23555 → 2355520 = 1,177.75 N·m

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Dynamic average of ignition angle delay adjustment TARRACO_DYNAMIC_AVG_IGN_ANG

  • Service 22DID 294A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Ea888b boost pressure control, adaptation value 0 TARRACO_EA888B_BOOST_P_CTRL_0

  • Service 22DID 11FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2018 to 2026.

Ea888b boost pressure control, adaptation value 1 TARRACO_EA888B_BOOST_P_CTRL_1

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2018 to 2026.

Ea888b boost pressure control, adaptation value 2 TARRACO_EA888B_BOOST_P_CTRL_2

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2018 to 2026.

Ea888b boost pressure control, adaptation value 3 TARRACO_EA888B_BOOST_P_CTRL_3

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×281100
Range
-359.68 to 356.87
Unit
Raw value

In testing for 2018 to 2026.

Ea888b boost pressure regulator, commanded TARRACO_EA888B_BOOST_P_CMD

  • Service 22DID 11A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Early ignition counter, cylinder 1 TARRACO_EARLY_IGN_CNT_CYL_1

  • Service 22DID 1722
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder 2 TARRACO_EARLY_IGN_CNT_CYL_2

  • Service 22DID 1725
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder 3 TARRACO_EARLY_IGN_CNT_CYL_3

  • Service 22DID 1723
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, cylinder 4 TARRACO_EARLY_IGN_CNT_CYL_4

  • Service 22DID 1724
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, total, cylinder 1 TARRACO_EARLY_IGN_CNT_TOT_1

  • Service 22DID 1715
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, total, cylinder 2 TARRACO_EARLY_IGN_CNT_TOT_2

  • Service 22DID 1718
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, total, cylinder 3 TARRACO_EARLY_IGN_CNT_TOT_3

  • Service 22DID 1716
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Early ignition counter, total, cylinder 4 TARRACO_EARLY_IGN_CNT_TOT_4

  • Service 22DID 1717
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Effective injection duration TARRACO_EFFECTIVE_INJ_DUR

  • Service 22DID 15E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 ms
Unit
ms

In testing for 2018 to 2026.

Electric additional coolant pump control, high circle TARRACO_ELEC_ADDITIONAL_CLT

  • Service 22DID 1488
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2018 to 2026.

Engine air mass, specified value TARRACO_ENG_AIR_MASS_SPEC

  • Service 22DID 2037
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Engine control module temperature TARRACO_ENG_CTRL_MODULE_TConfirmed

  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x0AD3 = 2771 → 277110 = 277.1 °C

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022. Supported for 2021.

Engine drag torque TARRACO_ENG_DRAG_TQ

  • Service 22DID 209C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine oil level TARRACO_PQ35_OIL_LVL

  • Service 22DID 11BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val250
Range
-131.072 to 131.068 mm
Unit
mm

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil level current value TARRACO_ENG_OIL_LEVEL

  • Service 22DID 58D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Engine oil sump temperature TARRACO_ENG_OIL_SUMP_T

  • Service 22DID 15B7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−460
Range
-460 to 11336.3 °F
Unit
°F

In testing for 2018 to 2026.

Engine oil temperature TARRACO_EOT

  • Service 22DID 202F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Engine oil temperature sensor 2 TARRACO_EOT_SENS_2

  • Service 22DID 40D5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Engine outlet coolant temperature calculated TARRACO_ENG_OUTLET_ECT_CALC

  • Service 22DID 1063
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Engine protection, torque limit TARRACO_ENG_PROTECTION_TQ

  • Service 22DID 2BC0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine read 11BE, signed raw count TARRACO_11BE_RAWConfirmed

  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

0xFFDE = -34 → -34

Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.

Engine read 162D, raw count TARRACO_162D_RAWConfirmed

  • Service 22DID 162D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x80000000 = 2147483648 → 2,147,483,648

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engine temperature control actuator TARRACO_ENG_T_CTRL_ACTUATOR

  • Service 22DID 3D73
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Engine temperature management actuator, after-run stop TARRACO_ENG_T_MANAGEMENT_ACTUATOR_AFTER

  • Service 22DID 441D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Engine temperature management actuator, duty cycle activation TARRACO_ENG_T_MANAGEMENT_ACTUATOR

  • Service 22DID 441A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Engine temperature management actuator, raw value TARRACO_ENG_T_MANAGEMENT

  • Service 22DID 4419
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Engine temperature management actuator, specified value TARRACO_ENG_T_MANAGEMENT_SPEC

  • Service 22DID 3FE4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×122071000000
Range
-399.9989 to 100 %
Unit
%

In testing for 2018 to 2026.

Engine temperature management actuator, stop open TARRACO_ENG_T_MANAGEMENT_ACTUATOR_STOP

  • Service 22DID 441C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Engine torque TARRACO_ENG_TQ

  • Service 22DID 2002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque TARRACO_ENG_TQ_7E0

  • Service 22DID 437C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque TARRACO_ENG_TQ_7E1

  • Service 22DID 2002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque TARRACO_ENGINE_TORQUE

  • Service 22DID 1010
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Engine torque TARRACO_MQB_TCM_ENGINE_TORQUEConfirmed

  • Service 22DID 100C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x03C0 = 960 → 96020 = 48 N·m

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engine torque limitation TARRACO_MQB_TCM_ENGINE_TORQUE_LIMITATIONConfirmed

  • Service 22DID 100E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0x1540 = 5440 → 544020 = 272 N·m

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engine torque loss TARRACO_MQB_TCM_ENGINE_TORQUE_LOSSConfirmed

  • Service 22DID 100F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val20
Range
-1638.4 to 1638.35 N·m
Unit
N·m

0xFEAC = -340 → -34020 = -17 N·m

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Exhaust camshaft, adaptation bias TARRACO_EXH_CAM_ADPT_BIAS

  • Service 22DID 174A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2018 to 2026.

Exhaust camshaft, adaptation sensor tolerance TARRACO_EXH_CAM_ADPT_SENS

  • Service 22DID 1755
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2018 to 2026.

Exhaust gas jet volume in particle filter TARRACO_EXH_GAS_JET_VOLUME

  • Service 22DID 3D7E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700 L
Unit
L

In testing for 2018 to 2026.

Exhaust gas temperature TARRACO_EXH_GAS_T

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature - calculated after catalyst TARRACO_EXH_GAS_T_CALC_AFTER

  • Service 22DID 2AE9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29312500−273.15
Range
-273.15 to 1262.9904 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature at probe before precat, model value TARRACO_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE

  • Service 22DID 139C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature before catalyst TARRACO_EXHAUST_GAS_T_BEFORE_CATALYSTConfirmed

  • Service 22DID 1282
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val50−193.93
Range
-193.93 to 1116.77 °C
Unit
°C

0x78DC = 30940 → 3094050−193.93 = 424.87 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Exhaust gas temperature before catalytic converter TARRACO_EXH_GAS_T_BEFORE

  • Service 22DID 296F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature before gasoline particulate filter TARRACO_EXH_GAS_T_BEFORE_GPF

  • Service 22DID 082D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust gas temperature sensor 1 TARRACO_EXH_GAS_T_SENS_1

  • Service 22DID 2976
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Exhaust temperature before the catalyst, modeled TARRACO_EXH_T_BEFORE_CAT

  • Service 22DID 1421
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Front left deflector temperature TARRACO_CLIMATE_FR_L_DEFL_TConfirmed

  • Service 22DID 260C
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Front left temperature flap actual value TARRACO_CLIMATE_FR_L_T_FLP_ACT_VALUEConfirmed

  • Service 22DID 2622
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Front right deflector temperature TARRACO_CLIMATE_FR_R_DEFL_TConfirmed

  • Service 22DID 260D
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

0x03 = 3 → 33 = 1 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Front right temperature flap actual value TARRACO_CLIMATE_FR_R_T_FLP_ACT_VALUEConfirmed

  • Service 22DID 2626
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Fuel metering valve position TARRACO_PQ35_FUEL_METERConfirmed

  • Service 22DID 1148
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0100 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Gasoline particulate filter blockage rate calculated TARRACO_GPF_BLOCKAGE_RATE_CALC

  • Service 22DID 2AFB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1280
Range
0 to 51.1992
Unit
Number

In testing for 2018 to 2026.

Gasoline particulate filter blockage rate threshold calculated TARRACO_GPF_BLOCKAGE_RATE

  • Service 22DID 2AF9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1280
Range
0 to 51.1992
Unit
Number

In testing for 2018 to 2026.

Gasoline particulate filter blockage ratio calculated absolute TARRACO_GPF_BLOCKAGE_RAT

  • Service 22DID 0827
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100
Unit
Number

In testing for 2018 to 2026.

Gasoline particulate filter blockage ratio calculated relative TARRACO_GPF_BLOCKAGE_RAT_CALC_REL

  • Service 22DID 0828
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100
Unit
Number

In testing for 2018 to 2026.

Gasoline particulate filter high level moisture build-up TARRACO_GPF_HIGH_LEVEL

  • Service 22DID 24B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Raw value

In testing for 2018 to 2026.

Gasoline particulate filter high level of soot build-up TARRACO_GPF_HIGH_LEVEL_SOOT

  • Service 22DID 24B3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Gasoline particulate filter loading stage TARRACO_GPF_LOADING_STAGE

  • Service 22DID 082B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Gasoline particulate filter maximum ash build-up reached TARRACO_GPF_MAX_ASH_BUILD_UP

  • Service 22DID 24B5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510
Unit
Raw value

In testing for 2018 to 2026.

Gasoline particulate filter maximum soot build-up reached TARRACO_GPF_MAX_SOOT_BUILD

  • Service 22DID 24B4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Gasoline particulate filter oil ash load calculated TARRACO_GPF_OIL_ASH_LOAD

  • Service 22DID 0804
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Gasoline particulate filter oil ash mass TARRACO_GPF_OIL_ASH_MASS

  • Service 22DID 406C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

In testing for 2018 to 2026.

Gasoline particulate filter soot load calculated TARRACO_GPF_SOOT_LOAD_CALC

  • Service 22DID 0829
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Gasoline particulate filter soot mass calculated TARRACO_GPF_SOOT_MASS_CALC

  • Service 22DID 208B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Gasoline particulate filter water load TARRACO_GPF_WATER_LOAD

  • Service 22DID 0802
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Gasoline particulate filter water mass TARRACO_GPF_WATER_MASS

  • Service 22DID 2139
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Raw value

In testing for 2018 to 2026.

Generator current TARRACO_GEN_CURRENT

  • Service 22DID 2A1C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10+9
Range
0 to 6562.5 A
Unit
A

In testing for 2018 to 2026.

Generator load TARRACO_PQ35_GEN_LOADConfirmed

  • Service 22DID 105C
  • Module7E0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0100 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Generator load normalized value TARRACO_GENERATOR_LOAD_NORMALIZED_VALUE

  • Service 22DID 15CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Generator load signal TARRACO_GEN_LOAD_SIG

  • Service 22DID 2050
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Generator load signal TARRACO_GENERATOR_LOAD_SIG

  • Service 22DID 101C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Generator performance TARRACO_GENERATOR_PERFORMANCE

  • Service 22DID 1097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9424810000
Range
-308831.8464 to 308822.421 W
Unit
W

In testing for 2018 to 2026.

Generator torque request TARRACO_GENERATOR_TORQUE_REQUEST

  • Service 22DID 101B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Heater circulation pump, nominal value TARRACO_HEATER_CIRCULATION

  • Service 22DID 167F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Heater for nozzles active TARRACO_HEATER_FOR_NOZZLES_ACTIVEConfirmed

  • Service 22DID 1945
  • Module70E → 778
  • Every2 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x0E = 14 → 14

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Heater support pump, specified value TARRACO_HEATER_SUPPORT_PMP_SPEC

  • Service 22DID 4336
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Height correction TARRACO_HEIGHT_CORR

  • Service 22DID 1136
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000610348
Range
0 to 3.9999
Unit
Number

In testing for 2018 to 2026.

High pressure control, adaptation TARRACO_HIGH_P_CTRL_ADPT

  • Service 22DID 11D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2018 to 2026.

IGA_CYL_KNK, 0 TARRACO_IGA_CYL_KNK_0

  • Service 22DID 13F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2018 to 2026.

IGA_CYL_KNK, 1 TARRACO_IGA_CYL_KNK_1

  • Service 22DID 13F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2018 to 2026.

IGA_CYL_KNK, 2 TARRACO_IGA_CYL_KNK_2

  • Service 22DID 13F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2018 to 2026.

IGA_CYL_KNK, 3 TARRACO_IGA_CYL_KNK_3

  • Service 22DID 13F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×38−48
Range
-48 to 47.625 °
Unit
°

In testing for 2018 to 2026.

IGA_IGC, 0 TARRACO_IGA_IGC_0

  • Service 22DID 138A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2018 to 2026.

IGA_IGC, 1 TARRACO_IGA_IGC_1

  • Service 22DID 138B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2018 to 2026.

IGA_IGC, 2 TARRACO_IGA_IGC_2

  • Service 22DID 138C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2018 to 2026.

IGA_IGC, 3 TARRACO_IGA_IGC_3

  • Service 22DID 138D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×14994000−35.625
Range
-35.625 to 59.9362 °
Unit
°

In testing for 2018 to 2026.

Ignition angle current cylinder, actual value TARRACO_IGN_ANG_CURRENT_CYL_ACT

  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-25 to 25 °
Unit
°

In testing for 2018 to 2026.

Ignition timing angle retard, cylinder 4 TARRACO_IGNITION_TIMING_ANGLE_RETARD_C4

  • Service 22DID 10E5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×75100
Range
-24576 to 24575.25 °
Unit
°

In testing for 2018 to 2026.

Injector 2 rail pressure calibration point 1 TARRACO_PQ35_INJ_2_RAIL_P_1Confirmed

  • Service 22DID 10D3
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

0x0004 = 4 → 420000 = 0.0002 ms

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Injector 4 rail pressure calibration point 3 TARRACO_PQ35_INJ_4_RAIL_P_3Confirmed

  • Service 22DID 10DE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20000
Range
-1.6384 to 1.63 ms
Unit
ms

0x0000 = 0 → 020000 = 0 ms

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Inlet flaps - actual value TARRACO_INLET_FLAPS_ACT

  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Inlet flaps - requested value TARRACO_INLET_FLAPS_REQ

  • Service 22DID 11A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Intake air temperature before throttle valve, raw value TARRACO_IAT_BEFORE_THROTTLE

  • Service 22DID 15C1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Intake air temperature in intake manifold TARRACO_INTAKE_AIR_T_IN_INTAKE_MANIFOLD

  • Service 22DID 149E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Intake air temperature raw value TARRACO_IAT_RAW

  • Service 22DID 15C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Intake camshaft, adaptation bias TARRACO_INT_CAM_ADPT_BIAS

  • Service 22DID 174B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2018 to 2026.

Intake camshaft, adaptation sensor tolerance TARRACO_INT_CAM_ADPT_SENS

  • Service 22DID 1740
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.021973
Range
-720.0112 to 719.9892 °
Unit
°

In testing for 2018 to 2026.

Intake manifold pressure raw value TARRACO_INT_MANIFOLD_P_RAW

  • Service 22DID 3E70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2018 to 2026.

Intake manifold pressure, commanded TARRACO_INT_MANIFOLD_P_CMD

  • Service 22DID 11DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2018 to 2026.

Intake manifold pressure, corrected TARRACO_INT_MANIFOLD_P

  • Service 22DID 11DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2018 to 2026.

Intake manifold runner control, acknowledgment TARRACO_INT_MANIFOLD_RUNNER_CTRL

  • Service 22DID 206A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Intake manifold runner control, activation TARRACO_INT_MANIFOLD_RUNNER

  • Service 22DID 2069
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Intake model air mass flow filtered value TARRACO_INT_MODEL_AIR_MASS

  • Service 22DID 11AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Intake phase deviation, actual value TARRACO_INT_PHASE_DEV_ACT

  • Service 22DID 1800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2018 to 2026.

Integrated mass of air since engine start TARRACO_INTEGRATED_MASS_AIR

  • Service 22DID 1175
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2018 to 2026.

Integrated mass of air since the first engine start TARRACO_INTEGRATED_MASS_AIR_SINCE

  • Service 22DID 1743
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×888925000
Range
0 to 23301.6246
Unit
Raw value

In testing for 2018 to 2026.

Intercooler air output temperature TARRACO_PQ35_INTERCOOLER_AIR_OUTPUT_T

  • Service 22DID 1628
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2021, 2023 to 2026. Not supported for 2022.

Kick down TARRACO_MQB_TCM_KICK_DOWNConfirmed

  • Service 22DID 2114
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Kilometers driven since last event on K1 TARRACO_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1Confirmed

  • Service 22DID 115A
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

0x0002 = 2 → 2×10 = 20 km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Kilometers driven since last event on K2 TARRACO_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2Confirmed

  • Service 22DID 115C
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10
Range
0 to 7000 km
Unit
km

0x0002 = 2 → 2×10 = 20 km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Knock sensor 1 test TARRACO_KNOCK_SENS_1_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Knock sensor 2 test TARRACO_KNOCK_SENS_2_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Knock sensor 3 test TARRACO_KNOCK_SENS_3_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Knock sensor 4 test TARRACO_KNOCK_SENS_4_TEST

  • Service 22DID 393C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Knock sensor, cylinder 1 TARRACO_KNOCK_SENS_CYL_1

  • Service 22DID 3960
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Knock sensor, cylinder 1 TARRACO_KNOCK_SNS_C1_V_MS

  • Service 22DID 120E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2018 to 2026.

Knock sensor, cylinder 2 TARRACO_KNOCK_SENS_CYL_2

  • Service 22DID 3961
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Knock sensor, cylinder 2 TARRACO_KNOCK_SNS_C2_V_MS

  • Service 22DID 1211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2018 to 2026.

Knock sensor, cylinder 3 TARRACO_KNOCK_SENS_CYL_3

  • Service 22DID 3962
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Knock sensor, cylinder 3 TARRACO_KNOCK_SNS_C3_V_MS

  • Service 22DID 120F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2018 to 2026.

Knock sensor, cylinder 4 TARRACO_KNOCK_SENS_CYL_4

  • Service 22DID 3963
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

Knock sensor, cylinder 4 TARRACO_KNOCK_SNS_C4_V_MS

  • Service 22DID 1210
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×0.007629410000
Range
0 to 3276
Unit
Number

In testing for 2018 to 2026.

Lambda value at DPF inlet TARRACO_LAMBDA_DPF_INLET

  • Service 22DID 080E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767
Unit
Number

In testing for 2018 to 2026.

Lambda, actual value TARRACO_LAMBDA_ACT

  • Service 22DID 10D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1220750000000
Range
-7.9999 to 7.9997
Unit
Number

In testing for 2018 to 2026.

Launch control counter, variant 1 TARRACO_LAUNCH_CTRL_CNT_VAR_1

  • Service 22DID 1200
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Launch control counter, variant 2 TARRACO_LAUNCH_CTRL_CNT_VAR_2

  • Service 22DID 38F1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Leg deflector temperature TARRACO_CLIMATE_LEG_DEFL_TConfirmed

  • Service 22DID 2611
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Long term fuel trim at idle, direct injection TARRACO_LONG_TERM_FUEL_TRIM_IDLE

  • Service 22DID 177E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2018 to 2026.

Long term fuel trim at idle, port injection TARRACO_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ

  • Service 22DID 1780
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×364
Range
-1536 to 100 %
Unit
%

In testing for 2018 to 2026.

Lower adapted coupling point K2 from micro-slip path adaptation TARRACO_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPTConfirmed

  • Service 22DID 110A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x2C = 44 → 44×5 = 220 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Main cat oxygen storage capacity age correction factor TARRACO_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR

  • Service 22DID 14F9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2018 to 2026.

Manifold absolute pressure, raw value TARRACO_MAP_RAW

  • Service 22DID 11DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2018 to 2026.

Manual engine starts counter TARRACO_MANUAL_ENG_STARTS

  • Service 22DID 2998
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Mass air flow over throttle valve TARRACO_MAF_OVER_THROTTLE

  • Service 22DID 394F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Mass air flow through throttle TARRACO_MAF_THROUGH_THROTTLE

  • Service 22DID 11AC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Mass air flow, commanded TARRACO_MAF_CMD

  • Service 22DID 11AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Raw value

In testing for 2018 to 2026.

Mass airflow sensor 1 bank 1 raw value TARRACO_MQB_MAF_1_B1_RAWConfirmed

  • Service 22DID 1026
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7
Unit
Raw value

0x0000 = 0 → 0×100010000 = 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Maximum ECU temperature TARRACO_MAX_ECU_T

  • Service 22DID 4649
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.1
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2018 to 2026.

Maximum oil level for the service interval TARRACO_MAX_OIL_LEVEL

  • Service 22DID 1230
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2018 to 2026.

Mean engine air mass TARRACO_MEAN_ENG_AIR_MASS

  • Service 22DID 2032
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Mean injection quantity TARRACO_MEAN_INJ_QTY

  • Service 22DID 2097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2018 to 2026.

Mean injection quantity TARRACO_MEAN_INJ_QUANTITYConfirmed

  • Service 22DID 1139
  • Module7E0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67
Unit
Raw value

0x3BF6 = 15350 → 15350100 = 153.5

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Minimum oil level for the service interval TARRACO_MIN_OIL_LEVEL

  • Service 22DID 1231
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2018 to 2026.

Misfires / 1000 revolutions, cylinder 1 TARRACO_MISFIRES_1000REV_C1Confirmed

  • Service 22DID 1147
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Misfires / 1000 revolutions, cylinder 2 TARRACO_MISFIRES_1000REV_C2Confirmed

  • Service 22DID 114A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Misfires per 1000 revolutions, cylinder 1, port injection TARRACO_MIS_PER_1000_1

  • Service 22DID 426B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires per 1000 revolutions, cylinder 2, port injection TARRACO_MIS_PER_1000_2

  • Service 22DID 426C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires per 1000 revolutions, cylinder 3, port injection TARRACO_MIS_PER_1000_3

  • Service 22DID 426D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires per 1000 revolutions, cylinder 4, port injection TARRACO_MIS_PER_1000_4

  • Service 22DID 426E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires total TARRACO_MIS_TOT

  • Service 22DID 2904
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires total TARRACO_MISFIRES_TOTALConfirmed

  • Service 22DID 1146
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Misfires, cylinder 1 TARRACO_MISFIRES_C1

  • Service 22DID 2966
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 2 TARRACO_MISFIRES_C2

  • Service 22DID 2969
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 3 TARRACO_MISFIRES_C3

  • Service 22DID 2967
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 3 TARRACO_MISFIRES_C3_ECMConfirmed

  • Service 22DID 1150
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0CD6 = 3286 → 3,286

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Misfires, cylinder 4 TARRACO_MISFIRES_C4

  • Service 22DID 2968
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Mixture adaptation factor at partial load TARRACO_MIXTURE_ADPT_FACTOR

  • Service 22DID 3996
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

N_32 TARRACO_N_32

  • Service 22DID 117D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2018 to 2026.

NL_PRE, 0 TARRACO_NL_PRE_0

  • Service 22DID 13F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2018 to 2026.

NL_PRE, 1 TARRACO_NL_PRE_1

  • Service 22DID 13F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2018 to 2026.

NL_PRE, 2 TARRACO_NL_PRE_2

  • Service 22DID 13F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2018 to 2026.

NL_PRE, 3 TARRACO_NL_PRE_3

  • Service 22DID 13F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×38147500000000
Range
0 to 4.9999 V
Unit
V

In testing for 2018 to 2026.

Number of injections TARRACO_NUM_INJECTIONS

  • Service 22DID 430E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Number of times the permitted centrifugal oil temperature has been exceeded TARRACO_NUM_TIMES_PERMITTED_T

  • Service 22DID 1154
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Number of warnings due to increased centrifugal oil temperature TARRACO_NUM_WARN_HI_CENTRIF_T

  • Service 22DID 1155
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Oil level TARRACO_OIL_LEVELConfirmed

  • Service 22DID 11BA
  • Module7E0
  • Every30 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

0x2A17 = 10775 → 107752500 = 4.31 cm

Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.

Oil level test method 1 TARRACO_OIL_LEVEL_TEST_1

  • Service 22DID 4E51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Oil level test method 2 TARRACO_OIL_LEVEL_TEST_2

  • Service 22DID 4E52
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Oil level test method 3 TARRACO_OIL_LEVEL_TEST_3

  • Service 22DID 4E53
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Oil level, average dynamic value TARRACO_OIL_LEVEL_AVG

  • Service 22DID 15B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2018 to 2026.

Oil level, static measured TARRACO_OIL_LEVEL_STATIC

  • Service 22DID 15A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 mm
Unit
mm

In testing for 2018 to 2026.

Oil pressure actual current TARRACO_MQB_TCM_EOP_ACTUAL_IConfirmed

  • Service 22DID 381E
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 mA
Unit
mA

0x1F28 = 7976 → 797610 = 797.6 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Oil pressure sensor raw value TARRACO_OIL_P_SENS_RAW

  • Service 22DID 4FBE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2018 to 2026.

Oil pressure sensor-piston cooling nozzle switch, status TARRACO_OIL_P_SENS_PISTON

  • Service 22DID 15BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Oil pressure switch activation, high pressure TARRACO_OIL_P_SWITCH_P

  • Service 22DID 20A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Oil pressure switch for high pressure, closed TARRACO_OIL_P_SWITCH_HIGH_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Oil pressure switch for low pressure, closed TARRACO_OIL_P_SWITCH_LOW_P

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Oil pressure switch for piston-cooling jets, closed TARRACO_OIL_P_SWITCH_PISTON

  • Service 22DID 4270
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Oil pressure target TARRACO_OIL_P_TGT

  • Service 22DID 4F70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 2018 to 2026.

Oil pressure valve switch, control TARRACO_OIL_P_VLV_SWITCH

  • Service 22DID 11B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Oil thermal wear TARRACO_DASH_OIL_THERMAL_WEARConfirmed

  • Service 22DID 224B
  • Module714 → 77E
  • Every300 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0068 = 104 → 104 km

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Open cam shaft angle at quantity control valve TARRACO_OPEN_CAM_SHFT_ANG

  • Service 22DID 10EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2018 to 2026.

Outside temperature TARRACO_OUTSIDE_T

  • Service 22DID 220C
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

In testing for 2018 to 2026.

Outside temperature, system calculated TARRACO_OUTSIDE_T_SYSTEMConfirmed

  • Service 22DID 260A
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °C
Unit
°C

0x02 = 2 → 22 = 1 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Oxygen sensor 1 bank 1 ceramic temperature TARRACO_OXYGEN_SNS_1_BANK_1_CERAMIC_T

  • Service 22DID 1290
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×234.3710000−273.15
Range
-273.15 to 1262.793 °C
Unit
°C

In testing for 2018 to 2026.

Particle filter, field regeneration request status TARRACO_PARTICLE_FLT_FIELDConfirmed

  • Service 22DID 115B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Piston cooling nozzles, control TARRACO_PISTON_COOLING

  • Service 22DID 16F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Piston-cooling jets, activation TARRACO_PISTON_COOLING_JETS

  • Service 22DID 4286
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Pre-injection 2 duration TARRACO_PQ35_PRE_INJ_2_DURATIONConfirmed

  • Service 22DID 14D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.41000
Range
-13.1072 to 13.1068 ms
Unit
ms

0x77FF = 30719 → 30719×0.41000 = 12.2876 ms

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Pressure before throttle valve - actual value TARRACO_P_BEFORE_THROTTLE_ACT

  • Service 22DID 11EE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×564
Range
0 to 5119.9218
Unit
Raw value

In testing for 2018 to 2026.

Pressure before throttle valve - sensor measured TARRACO_P_BEFORE_THROTTLE

  • Service 22DID 11EF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×21333546125
Range
0 to 2559.96
Unit
Raw value

In testing for 2018 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_1 TARRACO_PSN_EDGE_REL_AD_CAM_1

  • Service 22DID 1184
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2018 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_EX_2 TARRACO_PSN_EDGE_REL_AD_CAM_2

  • Service 22DID 1185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2018 to 2026.

PSN_EDGE_REL_AD_CAM_SAVE_IN_1 TARRACO_PSN_EDGE_REL_AD_CAM_SAVE_1

  • Service 22DID 1186
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °
Unit
°

In testing for 2018 to 2026.

Radiator fan actual duty TARRACO_CLIMATE_RAD_FAN_ACT_DUTYConfirmed

  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.5 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Radiator fan commanded duty TARRACO_CLIMATE_RAD_FAN_CMD_DUTYConfirmed

  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.5 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Rated drive torque TARRACO_RATED_DRIVE_TQ

  • Service 22DID 14A1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2018 to 2026.

Reached maximum temperature TARRACO_PQ35_REACHED_MAXIMUM_TConfirmed

  • Service 22DID 1117
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

0x0075 = 117 → 117 °C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Rear cat converter temperature, main catalytic converter model value TARRACO_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE

  • Service 22DID 1272
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Rear deflector temperature TARRACO_CLIMATE_RR_DEFL_TConfirmed

  • Service 22DID 263D
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 84.915 °C
Unit
°C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Refrigerant pressure TARRACO_CLIMATE_REFRIG_PConfirmed

  • Service 22DID 2605
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 bar
Unit
bar

0x11 = 17 → 175 = 3.4 bar

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Relative load value TARRACO_REL_LOAD

  • Service 22DID 1216
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0234403081
Range
0 to 1536.1605
Unit
Number

In testing for 2018 to 2026.

Relay for reserve coolant pump status TARRACO_RELAY_RESERVE_CLT

  • Service 22DID 3999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Requested torque, amount for auxiliary units TARRACO_REQ_TQ_AMOUNT

  • Service 22DID 10BE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Result of crankcase ventilation test, fail TARRACO_RESULT_CRANKCASE_VENTILATION_TEST

  • Service 22DID 15CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Result of crankcase ventilation test, successful TARRACO_RESULT_CRANKCASE

  • Service 22DID 15CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Secondary air injection sensor 1 TARRACO_SECONDARY_AIR_INJ_1

  • Service 22DID 3F68
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2018 to 2026.

SEG_AD_MMV_ER_H, 0 TARRACO_SEG_AD_MMV_ER_H_0

  • Service 22DID 1138
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_H, 2 TARRACO_SEG_AD_MMV_ER_H_2

  • Service 22DID 113A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_H, 3 TARRACO_SEG_AD_MMV_ER_H_3

  • Service 22DID 113B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_L, 0 TARRACO_SEG_AD_MMV_ER_L_0

  • Service 22DID 113E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_L, 2 TARRACO_SEG_AD_MMV_ER_L_2

  • Service 22DID 1140
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_L, 3 TARRACO_SEG_AD_MMV_ER_L_3

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_MID, 0 TARRACO_SEG_AD_MMV_ER_MID_0

  • Service 22DID 1132
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_MID, 1 TARRACO_SEG_AD_MMV_ER_MID_1

  • Service 22DID 1133
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER_MID, 2 TARRACO_SEG_AD_MMV_ER_MID_2

  • Service 22DID 1134
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER, 1 TARRACO_SEG_AD_MMV_ER_1

  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER, 2 TARRACO_SEG_AD_MMV_ER_2

  • Service 22DID 112E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

SEG_AD_MMV_ER, 3 TARRACO_SEG_AD_MMV_ER_3

  • Service 22DID 112F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78123327670000
Range
-7.8125 to 7.8123 %
Unit
%

In testing for 2018 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2022.

Simulated DPF temperature TARRACO_SIMULATED_DPF_T

  • Service 22DID 3D7F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1
Range
-3549.9 to 3003.6 °C
Unit
°C

In testing for 2018 to 2026.

Spark efficiency deviation at idle, maximum TARRACO_SPARK_EFFICIENCY_DEV_MAX

  • Service 22DID 155B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Spark efficiency deviation at part load, maximum TARRACO_SPARK_EFFICIENCY_DEV_PART_MAX

  • Service 22DID 155C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Stop signal switch TARRACO_MQB_TCM_STOP_SIGNAL_SWITCHConfirmed

  • Service 22DID 3800
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Tank fill level diagnostic reference value TARRACO_TANK_FILL_LEVEL

  • Service 22DID 51D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2018 to 2026.

TCO_1_ST TARRACO_TCO_1_ST

  • Service 22DID 11D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2026.

TCO_1_SYS TARRACO_TCO_1_SYS

  • Service 22DID 11CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2026.

Temperature after evaporator TARRACO_CLIMATE_T_AFTER_EVAPConfirmed

  • Service 22DID 2612
  • Module746 → 7B0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val3
Range
-42.624 to 42.291 °C
Unit
°C

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Temperature sensor for engine temperature management TARRACO_T_SENS_ENG_T

  • Service 22DID 392A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Temperature sensor for engine temperature management, target value TARRACO_T_SENS_ENG_T_TGT

  • Service 22DID 40E2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

Test of catalytic converter status, canceled TARRACO_TEST_CATALYTIC_CONV_STAT

  • Service 22DID 2927
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Test of catalytic converter, measured value TARRACO_TEST_CATALYTIC_CONV

  • Service 22DID 2926
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535
Unit
Number

In testing for 2018 to 2026.

Thermostat, actual TARRACO_THERMOSTAT_ACT

  • Service 22DID 4418
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Thermostat, commanded TARRACO_THERMOSTAT_CMD

  • Service 22DID 4417
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×122071000000
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Throttle regulator nominal value TARRACO_THROTTLE_REGULATOR

  • Service 22DID 16C5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

TI_1_MPI, 0 TARRACO_TI_1_MPI_0

  • Service 22DID 13AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_1_MPI, 1 TARRACO_TI_1_MPI_1

  • Service 22DID 13AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_1_MPI, 2 TARRACO_TI_1_MPI_2

  • Service 22DID 13AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_1_MPI, 3 TARRACO_TI_1_MPI_3

  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_1, 1 TARRACO_TI_MES4_PLS_1_1

  • Service 22DID 13A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_1, 2 TARRACO_TI_MES4_PLS_1_2

  • Service 22DID 13A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_1, 3 TARRACO_TI_MES4_PLS_1_3

  • Service 22DID 13A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_2, 0 TARRACO_TI_MES4_PLS_2_0

  • Service 22DID 13A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_2, 1 TARRACO_TI_MES4_PLS_2_1

  • Service 22DID 13A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_2, 2 TARRACO_TI_MES4_PLS_2_2

  • Service 22DID 13A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_2, 3 TARRACO_TI_MES4_PLS_2_3

  • Service 22DID 13A7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_3, 0 TARRACO_TI_MES4_PLS_3_0

  • Service 22DID 13A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_3, 1 TARRACO_TI_MES4_PLS_3_1

  • Service 22DID 13A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_3, 2 TARRACO_TI_MES4_PLS_3_2

  • Service 22DID 13AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

TI_MES4_PLS_3, 3 TARRACO_TI_MES4_PLS_3_3

  • Service 22DID 13AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2018 to 2026.

Timing deviation after chain replacement, exhaust bank 1 TARRACO_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1

  • Service 22DID 417D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Timing deviation after chain replacement, intake bank 1 TARRACO_TIM_DEV_AFTER_CHAIN_1

  • Service 22DID 417B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Timing deviation after other repairs, intake bank 1 TARRACO_TIM_DEV_AFTER_OTHER_1

  • Service 22DID 417F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Timing deviation after other repairs, intake bank 1 TARRACO_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1

  • Service 22DID 4181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Timing deviation current value exhaust bank 1 TARRACO_TIM_DEV_CURRENT_EXH_1

  • Service 22DID 4185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Timing deviation current value intake bank 1 TARRACO_TIM_DEV_CURRENT_INT_1

  • Service 22DID 4183
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °
Unit
°

In testing for 2018 to 2026.

Torque converter: torque loss TARRACO_TORQUE_CONVERTER_TORQUE_LOSS

  • Service 22DID 7053
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque increase request from ESP TARRACO_TQ_INCREASE_REQ_ESP

  • Service 22DID 1340
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque limitation TARRACO_TORQUE_LIMITATION

  • Service 22DID 203F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque limitation TARRACO_TQ_LIM

  • Service 22DID 107D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque limitation TARRACO_TQ_LIM_7E0

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque limitation, clutch protection TARRACO_TQ_LIM_CLU

  • Service 22DID 20A0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque loss adaptation TARRACO_TQ_LOSS_ADPT

  • Service 22DID 2122
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque loss adaptation at idle TARRACO_TQ_LOSS_ADPT_IDLE

  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque loss adaptation, A/C compressor TARRACO_TQ_LOSS_ADPT_AC_COMP_7E0

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque reduction request from ESP TARRACO_TQ_REDUCTION_REQ_ESP

  • Service 22DID 133F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val10
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque request, sum of auxiliary aggregate TARRACO_TQ_REQ_SUM_AUXILIARY

  • Service 22DID 209B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2018 to 2026.

Total mass of gasoline and ethyl alcohol in oil TARRACO_TOT_MASS_GASOLINE

  • Service 22DID 1713
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.021333
Range
0 to 1398.0581
Unit
Raw value

In testing for 2018 to 2026.

Transmission fluid temperature, calculated TARRACO_ATF_T_CALCULATED

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 704E
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2018 to 2026.

Transmission fluid temperature, modeled maximum reached TARRACO_ATF_T_MODELED_MAX_REACHED

  • Service 22DID 7051
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

In testing for 2018 to 2026.

Upper adapted coupling point K1 from macro slip path adaptation TARRACO_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPTConfirmed

  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0xB8 = 184 → 184×5 = 920 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Upper adapted coupling point K2 from macro slip path adaptation TARRACO_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPTConfirmed

  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0xA9 = 169 → 169×5 = 845 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Valve lift system, result of last switch, intake TARRACO_VLV_LIFT_SYSTEM

  • Service 22DID 16BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Valve lift system, valve lift, exhaust TARRACO_VLV_LIFT_SYSTEM_VLV_LIFT

  • Service 22DID 16BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Valve lift system, valve lift, intake TARRACO_VLV_LIFT_SYSTEM_VLV

  • Service 22DID 16BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Valve timing, the difference between the, actual and the set angle TARRACO_VLV_TIM_DIFF_ACT_SET

  • Service 22DID 10EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °
Unit
°

In testing for 2018 to 2026.

Variable valve timing, intake, bank 1, regulation TARRACO_VARIABLE_VLV_TIM_INT_1

  • Service 22DID 127B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Variable valve timing, intake, bank 1, switch on TARRACO_VARIABLE_VLV_TIM_INT_1_ON

  • Service 22DID 127D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517549
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Wear index %, 0=new engine TARRACO_WEAR_INDEX_0_NEW_ENG

  • Service 22DID 20C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

DPF

Soot mass calculated TARRACO_PQ35_SOOT_MASS_CALCConfirmed

  • Service 22DID 114F
  • Module7E0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Raw value

0x0E3F = 3647 → 3647100 = 36.47

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2022.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2022.

Fluids

Oil level, critical TARRACO_OIL_CRITConfirmed

  • Service 22DID 11BB
  • Module7E0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

0x2F00 = 12032 → 120322500 = 4.8128 cm

Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.

Fuel

Activation of fuel pump electronics TARRACO_ACTIVATION_FUEL_PMP

  • Service 22DID 2028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2022. Supported for 2021.

Fuel consumption TARRACO_FUEL_CONSConfirmed

  • Service 22DID 113F
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

0x0000 = 0 → 0100 = 0 L

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Fuel consumption - actual drive cycle TARRACO_FUEL_CONS_ACT_DRIVE

  • Service 22DID 1519
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2018 to 2026.

Fuel consumption per driving cycle TARRACO_FUEL_CONS_PER

  • Service 22DID 51D6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2018 to 2026.

Fuel consumption since last DPF regeneration TARRACO_FUEL_CONS_SINCE_DPF

  • Service 22DID 20D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2018 to 2026.

Fuel high pressure, actual value TARRACO_FUEL_HIGH_P_ACT

  • Service 22DID 2027
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2018 to 2026.

Fuel high pressure, control deviation TARRACO_FUEL_HIGH_P_CTRL_DEV

  • Service 22DID 20BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 bar
Unit
bar

In testing for 2018 to 2026.

Fuel high pressure, specified value TARRACO_FUEL_HIGH_P_SPEC

  • Service 22DID 293B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2018 to 2026.

Fuel level input % TARRACO_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Fuel level input, v1 TARRACO_FUEL_LEVEL_INPUT_V1Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 14B4
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

0x0384 = 900 → 900100 = 9 L

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Fuel low pressure, actual value TARRACO_FUEL_LOW_P_ACT

  • Service 22DID 2025
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2018 to 2026.

Fuel low pressure, specified value TARRACO_FUEL_LOW_P_SPEC

  • Service 22DID 2932
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2018 to 2026.

Fuel metering valve TARRACO_FUEL_METERING_VLV

  • Service 22DID 209A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Fuel mix correction coefficient TARRACO_FUEL_MIX_CORR

  • Service 22DID 1710
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518−273.1
Range
-273.1 to -73.1003
Unit
Number

In testing for 2018 to 2026.

Fuel part from EVAP system TARRACO_FUEL_PART_EVAP

  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×781100000
Range
-0.9996 to 0.9918
Unit
Number

In testing for 2018 to 2026.

Fuel pump adaptation TARRACO_FUEL_PMP_ADPT

  • Service 22DID 11C9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kPa
Unit
kPa

In testing for 2018 to 2026.

Fuel pump, commanded duty TARRACO_FUEL_PMP_CMD_DUTY

  • Service 22DID 11A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0015258743
Range
0 to 99.998 %
Unit
%

In testing for 2018 to 2026.

Fuel rate TARRACO_FUEL_RATE

  • Service 22DID 204C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2018 to 2026.

Fuel rate difference, injector/sensor TARRACO_FUEL_RATE_DIFF_INJ

  • Service 22DID 180A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×195315000000
Range
-127.9983 to 127.9944 L
Unit
L

In testing for 2018 to 2026.

Fuel tank fill level TARRACO_FUEL_TANK_FILL_LEVEL

  • Service 22DID 24FC
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5 L
Unit
L

In testing for 2018 to 2026.

Fuel temperature TARRACO_FUEL_T

  • Service 22DID 128A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Fuel temperature TARRACO_FUEL_T_7E0

  • Service 22DID 203E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2018 to 2026.

High fuel pressure, actual TARRACO_HIGH_FUEL_P_ACT

  • Service 22DID 159F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2018 to 2026.

High fuel pressure, actual value TARRACO_HIGH_FUEL_P_ACT_7E0

  • Service 22DID 4460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700
Unit
Raw value

In testing for 2018 to 2026.

High fuel pressure, commanded TARRACO_HIGH_FUEL_P_CMD

  • Service 22DID 11D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 32.7675
Unit
Raw value

In testing for 2018 to 2026.

High fuel pressure, regulation error TARRACO_HIGH_FUEL_P

  • Service 22DID 11D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2000
Range
-16.384 to 16.3835
Unit
Raw value

In testing for 2018 to 2026.

Long term fuel trim bank 1 TARRACO_LONG_TERM_FUEL_TRIM_1

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2018 to 2026.

Long term fuel trim direct injection at load TARRACO_LONG_TERM_FUEL_TRIM

  • Service 22DID 1779
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2018 to 2026.

Long term fuel trim port injection at load TARRACO_LONG_TERM_FUEL_TRIM_PORT

  • Service 22DID 177B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1999976553500000
Range
0 to 1.9999
Unit
Number

In testing for 2018 to 2026.

Low fuel pressure, actual TARRACO_LOW_FUEL_P_ACT

  • Service 22DID 11C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2018 to 2026.

Low fuel pressure, commanded TARRACO_LOW_FUEL_P_CMD

  • Service 22DID 11CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2018 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual TARRACO_RAT_EVAPORATED_FUEL_ACT

  • Service 22DID 1711
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×781100000
Range
0 to 1.9915
Unit
Number

In testing for 2018 to 2026.

Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum TARRACO_RAT_EVAPORATED_FUEL_MAX

  • Service 22DID 1712
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×8310625
Range
0 to 1.992
Unit
Number

In testing for 2018 to 2026.

Short term fuel trim bank 1 TARRACO_SHORT_TERM_FUEL_TRIM_1

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532−100
Range
-100 to 99.2187 %
Unit
%

In testing for 2018 to 2026.

GPS

Satellites, tracked TARRACO_GPS_SATS_TRACKEDConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x10 = 16 → 16

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Satellites, visible TARRACO_GPS_SATS_VISIBLEConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x04 = 4 → 4

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Movement

A/C compressor speed TARRACO_CLIMATE_A_C_COMP_SPDConfirmed

  • Service 22DID 2603
  • Module746 → 7B0
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

0x00 = 0 → 0×100 = 0 rpm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Acceleration TARRACO_ACCELERATION_29BIT

  • Service 22DID 12B0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Accelerator pedal position TARRACO_ACCEL_PEDAL_POS

  • Service 22DID 3804
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Accelerator pedal position 1 TARRACO_ACCEL_PEDAL_POS_1

  • Service 22DID F449
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Accelerator pedal position 2 TARRACO_ACCEL_PEDAL_POS_2

  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Accelerator pedal sensor 1 TARRACO_PQ35_ACCEL_PED_1Confirmed

  • Service 22DID 1221
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553.6 to 6553.4 mV
Unit
mV

0xFFB8 = -72 → -725 = -14.4 mV

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Accelerator pedal torque limit TARRACO_ACCEL_PEDAL_TQ_LIM

  • Service 22DID 1059
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Camshaft speed TARRACO_CAMSHAFT_VSS

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×250010000
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2018 to 2026.

Compressor speed TARRACO_COMP_SPD

  • Service 22DID 46E1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2018 to 2026.

Crankshaft speed TARRACO_CRANKSHAFT_VSS

Pelican can show this parameter as the engine speed.

  • Service 22DID 16F3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

In testing for 2018 to 2026.

Crankshaft speed, RPM TARRACO_CRANK_SPD_RPM

  • Service 22DID 206E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2018 to 2026.

Diesel particulate filter exhaust speed TARRACO_DPF_EXH_SPD

  • Service 22DID 44F9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655.36 to 655.34
Unit
Raw value

In testing for 2018 to 2026.

Engine RPM TARRACO_RPM

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 7000 rpm
Unit
rpm

In testing for 2018 to 2026.

Engine RPM at idle required TARRACO_ENGINE_RPM_AT_IDLE_REQUIRED

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2018 to 2026.

Front left wheel speed TARRACO_TIRE_FL_SPD_V3

  • Service 22DID 1002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Front right wheel speed TARRACO_TIRE_FR_SPD_V3Confirmed

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2020, 2023 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Idle speed specified rpm TARRACO_IDLE_SPD_SPEC_RPM

  • Service 22DID 4056
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2018 to 2026.

Input shaft speed 1 TARRACO_INPUT_SHFT_SPD_1

  • Service 22DID 70E0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 7000 rpm
Unit
rpm

In testing for 2018 to 2026.

Input shaft speed 2 TARRACO_INPUT_SHFT_SPD_2

  • Service 22DID 70E1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−1
Range
-32769 to 7000 rpm
Unit
rpm

In testing for 2018 to 2026.

Lateral acceleration TARRACO_LATERAL_ACCEL

  • Service 22DID 1644
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Longitudinal acceleration TARRACO_LONGITUDINAL_ACCEL

  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Longitudinal acceleration, raw TARRACO_LONGTITUDINAL_ACCELERATION_RAW_VALUE

  • Service 22DID 15CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1010000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Misfires/1000 rpm, cylinder 1 TARRACO_MISFIRES_1000_RPM_C1

  • Service 22DID 291D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires/1000 rpm, cylinder 2 TARRACO_MISFIRES_1000_RPM_C2

  • Service 22DID 2920
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires/1000 rpm, cylinder 3 TARRACO_MISFIRES_1000_RPM_C3

  • Service 22DID 291E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires/1000 rpm, cylinder 4 TARRACO_MISFIRES_1000_RPM_C4

  • Service 22DID 291F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Mixture adaptation factor at idle speed TARRACO_MIXTURE_ADPT_FACTOR_IDLE

  • Service 22DID 3997
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

In testing for 2018 to 2026.

Rear left wheel speed TARRACO_TIRE_RL_SPD_V3Confirmed

  • Service 22DID 1004
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Rear right wheel speed TARRACO_TIRE_RR_SPD_V3

  • Service 22DID 1003
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Specified idle RPM TARRACO_MQB_DQ250_SPECIFIED_IDLE_RPMConfirmed

  • Service 22DID 3871
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

0x0258 = 600 → 600 rpm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Speed ​​output TARRACO_MQB_DQ250_SPD_OUTPUTConfirmed

  • Service 22DID 1009
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

0x0158 = 344 → 344 rpm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Transmission input shaft speed TARRACO_PQ35_TRANS_IN_SPDConfirmed

  • Service 22DID 11F1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

0x0CD2 = 3282 → 32822 = 1,641 rpm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Transmission input speed TARRACO_MQB_TCM_TRANSMISSION_INPUT_SPD_7E1_380AConfirmed

  • Service 22DID 380A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x051E = 1310 → 1,310 rpm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Transmission output speed TARRACO_MQB_TCM_TRANSMISSION_OUTPUT_SPD_7E1_380BConfirmed

  • Service 22DID 380B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0143 = 323 → 323 rpm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Vehicle lateral acceleration, raw value TARRACO_VEHICLE_LATERAL_ACCELERATION_RAW_VALUE

  • Service 22DID 15D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67 g
Unit
g

In testing for 2018 to 2026.

Vehicle speed TARRACO_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Vehicle speed from transmission TARRACO_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSIONConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID 100A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 km/h
Unit
km/h

0x0216 = 534 → 53410 = 53.4 km/h

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Yaw acceleration, raw value TARRACO_YAW_ACCEL_RAW

  • Service 22DID 15D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

In testing for 2018 to 2026.

Stats

Crashes, driver side TARRACO_CRASH_DRVRConfirmed

  • Service 22DID 2354
  • Module715 → 77F
  • Every1 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Crashes, front TARRACO_CRASH_FRONTConfirmed

  • Service 22DID 2353
  • Module715 → 77F
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.

Crashes, passenger side TARRACO_CRASH_PASSConfirmed

  • Service 22DID 2355
  • Module715 → 77F
  • Every1 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Crashes, rear TARRACO_CRASH_REARConfirmed

  • Service 22DID 2356
  • Module715 → 77F
  • Every1 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Rollovers TARRACO_ROLLOVERConfirmed

  • Service 22DID 2357
  • Module715 → 77F
  • Every1 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Tires

Steering wheel angle TARRACO_MQB_SWAConfirmed

  • Service 22DID 1812
  • Module712 → 77C
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8+0.06
Range
-4095.94 to 4095.935 °
Unit
°

0x1768 = 5992 → 59928+0.06 = 749.06 °

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Steering wheel temperature TARRACO_STEER_WHL_T

  • Service 22DID 5505
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2018 to 2026.

Steering wheel torque sensor 1 TARRACO_STEER_WHL_TQ_SENS_1

  • Service 22DID 1805
  • Module712 → 77C
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.004395+0.06
Range
-143.9553 to 144.0709 °
Unit
°

In testing for 2018 to 2026.

Steering wheel torque sensor 2 TARRACO_STEER_WHL_TQ_SENS_2

  • Service 22DID 1806
  • Module712 → 77C
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.004395+0.06
Range
-143.9553 to 144.0709 °
Unit
°

In testing for 2018 to 2026.

Transmission

Actual position of gear positioner A TARRACO_MQB_DQ250_ACUTAL_POS_GEAR_POSER_AConfirmed

  • Service 22DID 3852
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Actual position of gear positioner B TARRACO_MQB_DQ250_ACUTAL_POS_GEAR_POSER_BConfirmed

  • Service 22DID 385A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

0x0357 = 855 → 855×10010000 = 8.55 mm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Actual position of gear positioner C TARRACO_MQB_DQ250_ACUTAL_POS_GEAR_POSER_CConfirmed

  • Service 22DID 3862
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

0x0357 = 855 → 855×10010000 = 8.55 mm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Actual position of gear positioner D TARRACO_MQB_DQ250_ACUTAL_POS_GEAR_POSER_DConfirmed

  • Service 22DID 386A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 327.67 mm
Unit
mm

0x0008 = 8 → 8×10010000 = 0.08 mm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch 1 actual pressure TARRACO_PQ35_CLUTCH_1_ACTUAL_PConfirmed

  • Service 22DID 38EB
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0000 = 0 → 0100 = 0 bar

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch 1 actual pressure raw value TARRACO_PQ35_DL382_CLUTCH_1_ACTUAL_P_RAW_VALUEConfirmed

  • Service 22DID 10F9
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−1
Range
-1 to 24.5 bar
Unit
bar

0x34 = 52 → 5210−1 = 4.2 bar

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch 1 failed adaptations counter TARRACO_PQ35_CLUTCH_1_FAILED_ADAPTS_COUNTERConfirmed

  • Service 22DID 10CC
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch 1 successful adaptations counter TARRACO_PQ35_CLUTCH_1_SUCCESSFUL_ADAPTS_COUNTERConfirmed

  • Service 22DID 10C9
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x1B6F = 7023 → 7,023

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch 1 valve current: actual TARRACO_MQB_DQ250_CLUTCH_1_VALVE_I_ACTUALConfirmed

  • Service 22DID 3835
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

0x1321 = 4897 → 489710 = 489.7 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch 1 valve current: specified TARRACO_MQB_DQ250_CLUTCH_1_VALVE_I_SPECIFIEDConfirmed

  • Service 22DID 3834
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276.7 mA
Unit
mA

0x1304 = 4868 → 486810 = 486.8 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch 2 actual pressure TARRACO_PQ35_CLUTCH_2_ACTUAL_PConfirmed

  • Service 22DID 38EA
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0007 = 7 → 7100 = 0.07 bar

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch 2 failed adaptations counter TARRACO_PQ35_CLUTCH_2_FAILED_ADAPTS_COUNTERConfirmed

  • Service 22DID 10ED
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch 2 successful adaptations counter TARRACO_PQ35_CLUTCH_2_SUCCESSFUL_ADAPTS_COUNTERConfirmed

  • Service 22DID 10EA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x1643 = 5699 → 5,699

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch 2 valve current: actual TARRACO_MQB_DQ250_CLUTCH_2_VALVE_I_ACTUALConfirmed

  • Service 22DID 383E
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

0x130F = 4879 → 487910 = 487.9 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch 2 valve current: specified TARRACO_MQB_DQ250_CLUTCH_2_VALVE_I_SPECIFIEDConfirmed

  • Service 22DID 383D
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
0 to 3276.7 mA
Unit
mA

0x1544 = 5444 → 544410 = 544.4 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch adaptation values initial kill point 0 for K1 TARRACO_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K1Confirmed

  • Service 22DID 1156
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x31 = 49 → 49×5 = 245 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch adaptation values initial kill point 0 for K2 TARRACO_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K2Confirmed

  • Service 22DID 1157
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x2E = 46 → 46×5 = 230 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch adaptation values lower current point adaptation K1 TARRACO_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K1Confirmed

  • Service 22DID 1158
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x2E = 46 → 46×5 = 230 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Clutch adaptation values lower current point adaptation K2 TARRACO_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K2Confirmed

  • Service 22DID 1159
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x2D = 45 → 45×5 = 225 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Correction values for main press adaptation: high press on clutch 1 TARRACO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_1Confirmed

  • Service 22DID 1181
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0050 = 80 → 80100 = 0.8 bar

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Correction values for main press adaptation: low press on clutch 1 TARRACO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_1Confirmed

  • Service 22DID 1180
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0046 = 70 → 70100 = 0.7 bar

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Correction values for main pressure adaptation high pressure on clutch 2 TARRACO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_2Confirmed

  • Service 22DID 1183
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x003F = 63 → 63100 = 0.63 bar

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Correction values for main pressure adaptation low pressure on clutch 2 TARRACO_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_2Confirmed

  • Service 22DID 1182
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 bar
Unit
bar

0x0041 = 65 → 65100 = 0.65 bar

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Current gear TARRACO_CURRENT_GEAR

  • Service 22DID 3EDE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2018 to 2026.

Current gear TARRACO_MQB_TCM_I_GEAR_DQ200Confirmed

  • Service 22DID 3816
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253
Unit
Number

0x05 = 5 → 5−2 = 3

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Current lower pressure point clutch 1 from current to pressure adaptation TARRACO_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPTConfirmed

  • Service 22DID 1130
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x2E = 46 → 46×5 = 230 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Current lower pressure point clutch 2 from current to pressure adaptation TARRACO_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPTConfirmed

  • Service 22DID 1132
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0x2D = 45 → 45×5 = 225 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Current upper pressure point clutch 1 from current to pressure adaptation TARRACO_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPTConfirmed

  • Service 22DID 1131
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0xC8 = 200 → 200×5 = 1,000 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Current upper pressure point clutch 2 from current to pressure adaptation TARRACO_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPTConfirmed

  • Service 22DID 1133
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 mA
Unit
mA

0xC8 = 200 → 200×5 = 1,000 mA

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Driving strategy mountain factor TARRACO_PQ35_DRIVING_STRATEGY_MOUNTAIN_FACTORConfirmed

  • Service 22DID 1018
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Driving strategy sport factor TARRACO_PQ35_DRIVING_STRATEGY_SPORT_FACTORConfirmed

  • Service 22DID 1019
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1700255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×1700255 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engaged position side A gear selector 1-3 TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 1138
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engaged position side A gear selector 2-4 TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 1139
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engaged position side A gear selector 5 and neutral TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 113A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engaged position side A gear selector 6 and reverse TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 113B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engaged position side B gear selector 1-3 TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 1144
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engaged position side B gear selector 2-4 TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 1145
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engaged position side B gear selector 5 and neutral TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 1146
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engaged position side B gear selector 6 and reverse TARRACO_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 1147
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x0000 = 0 → 0×10010000 = 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Engine specified torque during transmission intervention TARRACO_ENG_SPEC_TQ_DURING

  • Service 22DID 2110
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2018 to 2026.

Gear TARRACO_GEAR_V2Confirmed

  • Service 22DID 14CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x04 = 4 → 4

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Gear selector synchronous position G1 TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G1Confirmed

  • Service 22DID 1179
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x159F = 5535 → 5535100 = 55.35 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Gear selector synchronous position G2 TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G2Confirmed

  • Service 22DID 117A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x11EE = 4590 → 4590100 = 45.9 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Gear selector synchronous position G3 TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G3Confirmed

  • Service 22DID 117B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x1215 = 4629 → 4629100 = 46.29 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Gear selector synchronous position G4 TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G4Confirmed

  • Service 22DID 117C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x155B = 5467 → 5467100 = 54.67 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Gear selector synchronous position G5 TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G5Confirmed

  • Service 22DID 117D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x1542 = 5442 → 5442100 = 54.42 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Gear selector synchronous position G6 TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G6Confirmed

  • Service 22DID 117E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x1548 = 5448 → 5448100 = 54.48 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Gear selector synchronous position, reverse TARRACO_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G_RConfirmed

  • Service 22DID 117F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
0 to 327.67 %
Unit
%

0x11E2 = 4578 → 4578100 = 45.78 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Input shaft 1 TARRACO_MQB_INPUT_SHAFT_1Confirmed

  • Service 22DID 380C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x051A = 1306 → 1,306 rpm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Input shaft 2 TARRACO_MQB_INPUT_SHAFT_2Confirmed

  • Service 22DID 380D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x054F = 1359 → 1,359 rpm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Lower adapted coupling point clutch 1 from kiss point adaptation TARRACO_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_KISS_POINT_ADAPTConfirmed

  • Service 22DID 388D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

0x31 = 49 → 49200 = 0.245 A

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Lower adapted coupling point clutch 2 from kiss point adaptation TARRACO_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_KISS_POINT_ADAPTConfirmed

  • Service 22DID 388E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

0x2E = 46 → 46200 = 0.23 A

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Neutral position gear selector 1-3 TARRACO_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 1140
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x1397 = 5015 → 5015×10010000 = 50.15 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Neutral position gear selector 2-4 TARRACO_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 1141
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x1382 = 4994 → 4994×10010000 = 49.94 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Neutral position gear selector 5 and neutral TARRACO_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 1142
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x1371 = 4977 → 4977×10010000 = 49.77 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Neutral position gear selector 6 and reverse TARRACO_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 1143
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x13A2 = 5026 → 5026×10010000 = 50.26 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Output shaft 1 TARRACO_MQB_OUTPUT_SHAFT_1Confirmed

  • Service 22DID 380E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x015E = 350 → 350 rpm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Output shaft 2 TARRACO_MQB_OUTPUT_SHAFT_2Confirmed

  • Service 22DID 380F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x4E01 = 19969 → 19,969 rpm

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Powertrain overall gear ratio TARRACO_POWERTRAIN_OVERALL

  • Service 22DID 11DF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35
Unit
Number

In testing for 2018 to 2026.

Road resistance TARRACO_PQ35_ROAD_RESISTANCEConfirmed

  • Service 22DID 1017
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24.9100−31.6
Range
-31 to 31.894 %
Unit
%

0x7F = 127 → 127×24.9100−31.6 = 0.023 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Selected gear TARRACO_SELECTED_GEAR

  • Service 22DID 7050
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−2
Range
-2 to 253 °C
Unit
°C

In testing for 2018 to 2026.

Specified torque clutch 1 TARRACO_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_1Confirmed

  • Service 22DID 382E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
0 to 1638.35 N·m
Unit
N·m

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Specified torque clutch 2 TARRACO_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_2Confirmed

  • Service 22DID 3838
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5100
Range
-1638 to 1638.35 N·m
Unit
N·m

0xD120 = -12000 → -12000×5100 = -600 N·m

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Synchronous position side A gear selector 1-3 TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 113C
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x1215 = 4629 → 4629×10010000 = 46.29 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Synchronous position side A gear selector 2-4 TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 113D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x11EE = 4590 → 4590×10010000 = 45.9 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Synchronous position side A gear selector 5 and neutral TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 113E
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x1344 = 4932 → 4932×10010000 = 49.32 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Synchronous position side A gear selector 6 and reverse TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 113F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x11E2 = 4578 → 4578×10010000 = 45.78 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Synchronous position side B gear selector 1-3 TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_1_3Confirmed

  • Service 22DID 1148
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x159F = 5535 → 5535×10010000 = 55.35 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Synchronous position side B gear selector 2-4 TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_2_4Confirmed

  • Service 22DID 1149
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x155B = 5467 → 5467×10010000 = 54.67 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Synchronous position side B gear selector 5 and neutral TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_5_NConfirmed

  • Service 22DID 114A
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x1542 = 5442 → 5442×10010000 = 54.42 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Synchronous position side B gear selector 6 and reverse TARRACO_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_6_RConfirmed

  • Service 22DID 114B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10010000
Range
0 to 655.35 %
Unit
%

0x1548 = 5448 → 5448×10010000 = 54.48 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Torque loss adaptation, A/C compressor + gear engaged TARRACO_TQ_LOSS_ADPT_AC_COMP

  • Service 22DID 1222
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Torque loss adaptation, gear engaged TARRACO_TQ_LOSS_ADPT_GEAR

  • Service 22DID 1224
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2018 to 2026.

Transmission coolant valve, open TARRACO_TRANS_CLT_VLV_OPEN

  • Service 22DID 3D74
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Transmission gear ratio TARRACO_TRANS_GEAR_RAT

  • Service 22DID 0327
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val100
Range
-1.28 to 1.27
Unit
Number

In testing for 2018 to 2026.

Upper adapted coupling point clutch 1 from microslip adaptation TARRACO_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_MICROSLIP_ADAPTConfirmed

  • Service 22DID 388F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

0xB8 = 184 → 184200 = 0.92 A

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Upper adapted coupling point clutch 2 from microslip adaptation TARRACO_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_MICROSLIP_ADAPTConfirmed

  • Service 22DID 3890
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 A
Unit
A

0xA9 = 169 → 169200 = 0.845 A

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Trips

Analysis, clutch 1 temperature time in range 1 TARRACO_ANALYSIS_CLU_1_T_1

  • Service 22DID 1066
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Analysis, clutch 1 temperature time in range 2 TARRACO_ANALYSIS_CLU_1_T_2

  • Service 22DID 1067
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Analysis, clutch 1 temperature time in range 3 TARRACO_ANALYSIS_CLU_1_T_3

  • Service 22DID 1068
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Analysis, clutch 2 temperature time in range 0 TARRACO_ANALYSIS_CLU_2_T_0

  • Service 22DID 107A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Analysis, clutch 2 temperature time in range 1 TARRACO_ANALYSIS_CLU_2_T_1

  • Service 22DID 107B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Analysis, clutch 2 temperature time in range 2 TARRACO_ANALYSIS_CLU_2_T_2

  • Service 22DID 107C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Analysis, clutch 2 temperature time in range 3 TARRACO_ANALYSIS_CLU_2_T_3

  • Service 22DID 107D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Clutch 1 temperature time in range 0 TARRACO_CLU_1_T_TIME_RANGE_0

  • Service 22DID 1065
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val50
Range
0 to 1310.7 s
Unit
s

In testing for 2018 to 2026.

Distance to empty TARRACO_DTE

Pelican can show this parameter as the fuel range.

  • Service 22DID 2294
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021 to 2022.

Drive cycles counter TARRACO_MQB_TCM_DRIVE_CYCLES_COUNTERConfirmed

  • Service 22DID 388B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x07E6 = 2022 → 2,022

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Driving time ecological TARRACO_MQB_TCM_DRIVING_TIME_ECOLOGICALConfirmed

  • Service 22DID 3888
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x22 = 34 → 34 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Driving time manual TARRACO_MQB_TCM_DRIVING_TIME_MANUALConfirmed

  • Service 22DID 388A
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x04 = 4 → 4 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Driving time sporty TARRACO_MQB_TCM_DRIVING_TIME_SPORTYConfirmed

  • Service 22DID 3889
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Gasoline particulate filter distance since last regeneration TARRACO_GPF_DIST_SINCE_REGEN

  • Service 22DID 208D
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2018 to 2026.

Ignition cycles TARRACO_MQB_TCM_IGNITION_CYCLESConfirmed

  • Service 22DID 388C
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x1CFE = 7422 → 7,422

Confirmed for 2022. In testing for 2018 to 2021, 2023 to 2026.

Mixture variation in adapted part load range 1 TARRACO_MIXTURE_VARIATION_1

  • Service 22DID 39BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

Odometer TARRACO_MQB_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 2A0A
  • Module710 → 77A
  • Every5 s
  • Testing for 2018 to 2020, 2023 to 2026

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777175 km
Unit
km

In testing for 2018 to 2020, 2023 to 2026. Supported for 2021 to 2022.

Odometer TARRACO_MQB_TCM_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 3841
  • Module7E1
  • Every30 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

0x069B0900 = 110823680 → 11082368010 = 11,082,368 km

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Odometer TARRACO_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 10E0
  • Module7E0
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

0x0000F70F = 63247 → 63,247 km

Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.

Odometer TARRACO_ODO_ECMConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • Module7E0
  • Every30 s
  • Testing for 2018 to 2020, 2022 to 2026

Example reply from a 2021 Seat Tarraco.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x0001EE = 494 → 494 km

Confirmed for 2021. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2022.

Odometer #2 TARRACO_MQB_TCM_ODO_2Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 3887
  • Module7E1
  • Every30 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

0x000ADE00 = 712192 → 71219210 = 71,219.2 km

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Odometer #3 TARRACO_PQ35_ODO_3Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 101A
  • Module7E1
  • Every30 s
  • Testing for 2018 to 2020, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x0FF700 = 1046272 → 1,046,272 km

Confirmed for 2021 to 2022. In testing for 2018 to 2020, 2023 to 2026.

Odometer with ECU installed TARRACO_ODO_ECU_INSTALLED

  • Service 22DID 295B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 m
Unit
m

In testing for 2018 to 2026.

Odometer, high resolution TARRACO_ODO_HDConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 1160
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2021, 2023 to 2026

Example reply from a 2022 Seat Tarraco.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 m
Unit
m

0x03C269B2 = 63072690 → 63,072,690 m

Confirmed for 2022. In testing for 2018 to 2020, 2023 to 2026. Not supported for 2021.

Odometer, mileage, HR TARRACO_ODO_MILEAGE_HR

  • Service 22DID 22B8
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2018 to 2026.

Operating time, temperature range 1 TARRACO_OP_TIME_T_RANGE_1

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2018 to 2026.

Operating time, temperature range 2 TARRACO_OP_TIME_T_RANGE_2

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2018 to 2026.

Operating time, temperature range 3 TARRACO_OP_TIME_T_RANGE_3

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2018 to 2026.

Operating time, temperature range 4 TARRACO_OP_TIME_T_RANGE_4

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2018 to 2026.

Operating time, temperature range 5 TARRACO_OP_TIME_T_RANGE_5

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2018 to 2026.

Operating time, temperature range 6 TARRACO_OP_TIME_T_RANGE_6

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val×23860742949672950
Range
0 to 23860.7 h
Unit
h

In testing for 2018 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.