Parameters
The Renault Zoe has 387 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
AC charging power available ZOE_AC_P_AVAILConfirmed
- Service 22
DID 300F - Module
DADA → DA - Every
2 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1638.375 kW
- Unit
- kW
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
AC mains current ZOE_AC_AConfirmed
- Service 22
DID 300D - Module
DADA → DA - Every
2 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 A
- Unit
- A
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
AC mains phases ZOE_AC_PHASESConfirmed
- Service 22
DID 300B - Module
DADA → DA - Every
2 s - Testing for 2012 to 2020, 2022 to 2024
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | ONE | One phase |
1 | TWO | Two phase |
2 | THREE | Three phase |
3 | NONE | Not detected |
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
AC mains voltage ZOE_AC_VConfirmed
- Service 22
DID 2B8A - Module
DADA → DA - Every
2 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Battery module 1 temperature ZOE_MOD_T1
- Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Battery module 2 temperature ZOE_MOD_T2
- Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Battery module 3 temperature ZOE_MOD_T3
- Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Battery module 4 temperature ZOE_MOD_T4
- Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Battery module 5 temperature ZOE_MOD_T5
- Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Battery module 6 temperature ZOE_MOD_T6
- Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Battery module 7 temperature ZOE_MOD_T7
- Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Battery module 8 temperature ZOE_MOD_T8
- Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Battery module 9 temperature ZOE_MOD_T9
- Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Battery module 10 temperature ZOE_MOD_T10
- Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Battery module 11 temperature ZOE_MOD_T11
- Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Battery module 12 temperature ZOE_MOD_T12
- Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Charge plug present ZOE_PLUGConfirmed
Pelican can show this parameter as the plug state.
- Service 22
DID 2B85 - Module
DADA → DA - Every
2 s - Testing for 2012 to 2020, 2022 to 2024
Bits 4 to 7 of the reply, 4 bits.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Charge state ZOE_CHG_STATEConfirmed
- Service 22
DID 2B6D - Module
DADA → DA - Every
2 s - Testing for 2012 to 2020, 2022 to 2024
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | STOPPED | Stopped |
1 | TIMER_WAIT | Waiting for timer |
2 | DONE | Done |
3 | CHARGING | Battery |
4 | INTERRUPTED | Interrupted |
5 | POWER_WAIT | Waiting for power |
6 | FLAP_OPEN | Charge flap open |
8 | PREPARING | Preparing |
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Charge type ZOE_CHG_TYPEConfirmed
- Service 22
DID 2B7A - Module
DADA → DA - Every
2 s - Testing for 2012 to 2020, 2022 to 2024
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | UNDEFINED | Undefined |
1 | TYPE2 | Type 2 |
2 | TYPE2 | Type 2 |
3 | CHADEMO | CHAdeMO |
4 | CCS |
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Complete charge cycles ZOE_CYCLESConfirmed
- Service 22
DID 9210 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2020 to 2021. Supported for 2022.
Energy charged, total ZOE_E_CHGConfirmed
- Service 22
DID 9243 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967.295 kWh
- Unit
- kWh
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Energy discharged, total ZOE_E_DISCHGConfirmed
- Service 22
DID 9245 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967.295 kWh
- Unit
- kWh
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Energy regenerated, total ZOE_E_REGENConfirmed
- Service 22
DID 9247 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967.295 kWh
- Unit
- kWh
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 13 to 14 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
2 | CIM | Charge increasing mode |
3 | Not PSA |
Confirmed for 2020 to 2021. Supported for 2022.
High voltage battery available energy ZOE_HV_E_AVAILConfirmed
- Service 22
DID 91C8 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777.215 kWh
- Unit
- kWh
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
High voltage battery average temperature ZOE_HV_TConfirmed
- Service 22
DID 9012 - Module
DADB → DB - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
High voltage battery current ZOE_HV_AConfirmed
Pelican can show this parameter as the traction battery current.
- Service 22
DID 925D - Module
DADB → DB - Every
2 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1027.97 to 1020 A
- Unit
- A
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
High voltage battery current ZOE_HV_A_3042Confirmed
- Service 22
DID 3042 - Module
DADA → DA - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -16383.75 to 16383.75 A
- Unit
- A
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
High voltage battery current, power electronics ZOE_HV_A_PEB
- Service 22
DID 3204 - Module
7E4 → 7EC - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -8192 to 8191.75 A
- Unit
- A
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
High voltage battery current, vehicle controller ZOE_HV_A_EVCConfirmed
- Service 22
DID 21CC - Module
DADA → DA - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -500 to 15883.75 A
- Unit
- A
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
High voltage battery voltage ZOE_HV_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 9005 - Module
DADB → DB - Every
2 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
High voltage battery voltage, power electronics ZOE_HV_V_PEB
- Service 22
DID 3203 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
High voltage battery voltage, vehicle controller ZOE_HV_V_EVCConfirmed
- Service 22
DID 20FE - Module
DADA → DA - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2021. Supported for 2022.
Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2020 to 2021. Supported for 2022.
Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.98 V
- Unit
- V
Confirmed for 2020 to 2021. Supported for 2022.
Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 15 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
Confirmed for 2020 to 2021. Supported for 2022.
Maximum charge power ZOE_CHG_P_MAXConfirmed
- Service 22
DID 9018 - Module
DADB → DB - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 kW
- Unit
- kW
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Pack temperature 1 ZOE_PACK_T1Confirmed
- Service 22
DID 9131 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Pack temperature 2 ZOE_PACK_T2Confirmed
- Service 22
DID 9132 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Pack temperature 3 ZOE_PACK_T3Confirmed
- Service 22
DID 9133 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Pack temperature 4 ZOE_PACK_T4Confirmed
- Service 22
DID 9134 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Pack temperature 5 ZOE_PACK_T5Confirmed
- Service 22
DID 9135 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Pack temperature 6 ZOE_PACK_T6Confirmed
- Service 22
DID 9136 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Pack temperature 7 ZOE_PACK_T7Confirmed
- Service 22
DID 9137 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Pack temperature 8 ZOE_PACK_T8Confirmed
- Service 22
DID 9138 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Pack temperature 9 ZOE_PACK_T9Confirmed
- Service 22
DID 9139 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Pack temperature 10 ZOE_PACK_T10Confirmed
- Service 22
DID 913A - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Pack temperature 11 ZOE_PACK_T11Confirmed
- Service 22
DID 913B - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Pack temperature 12 ZOE_PACK_T12Confirmed
- Service 22
DID 913C - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
State of charge ZOE_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID 9002 - Module
DADB → DB - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
State of charge ZOE_SOC_9002
- Service 22
DID 9002 - Module
DADA → DA - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
State of charge, battery controller ZOE_SOC_9001Confirmed
- Service 22
DID 9001 - Module
DADB → DB - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
State of charge, vehicle controller ZOE_SOC_EVC
- Service 22
DID 2002 - Module
DADA → DA - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 %
- Unit
- %
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
State of health ZOE_SOHConfirmed
Pelican can show this parameter as the state of health.
- Service 22
DID 9003 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cells
Cell 1 voltage ZOE_CELL_V1Confirmed
- Service 22
DID 9021 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 1 voltage ZOE_CELL1_V1
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 2 voltage ZOE_CELL_V2Confirmed
- Service 22
DID 9022 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 2 voltage ZOE_CELL1_V2
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 3 voltage ZOE_CELL_V3Confirmed
- Service 22
DID 9023 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 3 voltage ZOE_CELL1_V3
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 4 voltage ZOE_CELL_V4Confirmed
- Service 22
DID 9024 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 4 voltage ZOE_CELL1_V4
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 5 voltage ZOE_CELL_V5Confirmed
- Service 22
DID 9025 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 5 voltage ZOE_CELL1_V5
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 6 voltage ZOE_CELL_V6Confirmed
- Service 22
DID 9026 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 6 voltage ZOE_CELL1_V6
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 7 voltage ZOE_CELL_V7Confirmed
- Service 22
DID 9027 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 7 voltage ZOE_CELL1_V7
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 8 voltage ZOE_CELL_V8Confirmed
- Service 22
DID 9028 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 8 voltage ZOE_CELL1_V8
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 9 voltage ZOE_CELL_V9Confirmed
- Service 22
DID 9029 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 9 voltage ZOE_CELL1_V9
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 10 voltage ZOE_CELL_V10Confirmed
- Service 22
DID 902A - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 10 voltage ZOE_CELL1_V10
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 11 voltage ZOE_CELL_V11Confirmed
- Service 22
DID 902B - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 11 voltage ZOE_CELL1_V11
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 12 voltage ZOE_CELL_V12Confirmed
- Service 22
DID 902C - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 12 voltage ZOE_CELL1_V12
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 13 voltage ZOE_CELL_V13Confirmed
- Service 22
DID 902D - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 13 voltage ZOE_CELL1_V13
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 14 voltage ZOE_CELL_V14Confirmed
- Service 22
DID 902E - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 14 voltage ZOE_CELL1_V14
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 15 voltage ZOE_CELL_V15Confirmed
- Service 22
DID 902F - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 15 voltage ZOE_CELL1_V15
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 16 voltage ZOE_CELL_V16Confirmed
- Service 22
DID 9030 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 16 voltage ZOE_CELL1_V16
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 17 voltage ZOE_CELL_V17Confirmed
- Service 22
DID 9031 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 17 voltage ZOE_CELL1_V17
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 18 voltage ZOE_CELL_V18Confirmed
- Service 22
DID 9032 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 18 voltage ZOE_CELL1_V18
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 19 voltage ZOE_CELL_V19Confirmed
- Service 22
DID 9033 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 19 voltage ZOE_CELL1_V19
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 20 voltage ZOE_CELL_V20Confirmed
- Service 22
DID 9034 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 20 voltage ZOE_CELL1_V20
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 21 voltage ZOE_CELL_V21Confirmed
- Service 22
DID 9035 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 21 voltage ZOE_CELL1_V21
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 22 voltage ZOE_CELL_V22Confirmed
- Service 22
DID 9036 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 22 voltage ZOE_CELL1_V22
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 23 voltage ZOE_CELL_V23Confirmed
- Service 22
DID 9037 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 23 voltage ZOE_CELL1_V23
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 24 voltage ZOE_CELL_V24Confirmed
- Service 22
DID 9038 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 24 voltage ZOE_CELL1_V24
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 25 voltage ZOE_CELL_V25Confirmed
- Service 22
DID 9039 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 25 voltage ZOE_CELL1_V25
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 26 voltage ZOE_CELL_V26Confirmed
- Service 22
DID 903A - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 26 voltage ZOE_CELL1_V26
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 27 voltage ZOE_CELL_V27Confirmed
- Service 22
DID 903B - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 27 voltage ZOE_CELL1_V27
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 28 voltage ZOE_CELL_V28Confirmed
- Service 22
DID 903C - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 28 voltage ZOE_CELL1_V28
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 29 voltage ZOE_CELL_V29Confirmed
- Service 22
DID 903D - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 29 voltage ZOE_CELL1_V29
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 30 voltage ZOE_CELL_V30Confirmed
- Service 22
DID 903E - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 30 voltage ZOE_CELL1_V30
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 31 voltage ZOE_CELL_V31Confirmed
- Service 22
DID 903F - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 31 voltage ZOE_CELL1_V31
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 32 voltage ZOE_CELL_V32Confirmed
- Service 22
DID 9041 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 32 voltage ZOE_CELL1_V32
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 33 voltage ZOE_CELL_V33Confirmed
- Service 22
DID 9042 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 33 voltage ZOE_CELL1_V33
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 34 voltage ZOE_CELL_V34Confirmed
- Service 22
DID 9043 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 34 voltage ZOE_CELL1_V34
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 35 voltage ZOE_CELL_V35Confirmed
- Service 22
DID 9044 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 35 voltage ZOE_CELL1_V35
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 36 voltage ZOE_CELL_V36Confirmed
- Service 22
DID 9045 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 36 voltage ZOE_CELL1_V36
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 37 voltage ZOE_CELL_V37Confirmed
- Service 22
DID 9046 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 37 voltage ZOE_CELL1_V37
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 38 voltage ZOE_CELL_V38Confirmed
- Service 22
DID 9047 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 38 voltage ZOE_CELL1_V38
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 39 voltage ZOE_CELL_V39Confirmed
- Service 22
DID 9048 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 39 voltage ZOE_CELL1_V39
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 40 voltage ZOE_CELL_V40Confirmed
- Service 22
DID 9049 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 40 voltage ZOE_CELL1_V40
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 41 voltage ZOE_CELL_V41Confirmed
- Service 22
DID 904A - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 41 voltage ZOE_CELL1_V41
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 42 voltage ZOE_CELL_V42Confirmed
- Service 22
DID 904B - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 42 voltage ZOE_CELL1_V42
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 43 voltage ZOE_CELL_V43Confirmed
- Service 22
DID 904C - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 43 voltage ZOE_CELL1_V43
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 44 voltage ZOE_CELL_V44Confirmed
- Service 22
DID 904D - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 44 voltage ZOE_CELL1_V44
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 45 voltage ZOE_CELL_V45Confirmed
- Service 22
DID 904E - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 45 voltage ZOE_CELL1_V45
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 46 voltage ZOE_CELL_V46Confirmed
- Service 22
DID 904F - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 46 voltage ZOE_CELL1_V46
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 47 voltage ZOE_CELL_V47Confirmed
- Service 22
DID 9050 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 47 voltage ZOE_CELL1_V47
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 48 voltage ZOE_CELL_V48Confirmed
- Service 22
DID 9051 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 48 voltage ZOE_CELL1_V48
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 49 voltage ZOE_CELL_V49Confirmed
- Service 22
DID 9052 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 49 voltage ZOE_CELL1_V49
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 50 voltage ZOE_CELL_V50Confirmed
- Service 22
DID 9053 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 50 voltage ZOE_CELL1_V50
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 51 voltage ZOE_CELL_V51Confirmed
- Service 22
DID 9054 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 51 voltage ZOE_CELL1_V51
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 52 voltage ZOE_CELL_V52Confirmed
- Service 22
DID 9055 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 52 voltage ZOE_CELL1_V52
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 53 voltage ZOE_CELL_V53Confirmed
- Service 22
DID 9056 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 53 voltage ZOE_CELL1_V53
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 54 voltage ZOE_CELL_V54Confirmed
- Service 22
DID 9057 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 54 voltage ZOE_CELL1_V54
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 55 voltage ZOE_CELL_V55Confirmed
- Service 22
DID 9058 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 55 voltage ZOE_CELL1_V55
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 56 voltage ZOE_CELL_V56Confirmed
- Service 22
DID 9059 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 56 voltage ZOE_CELL1_V56
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 57 voltage ZOE_CELL_V57Confirmed
- Service 22
DID 905A - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 57 voltage ZOE_CELL1_V57
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 58 voltage ZOE_CELL_V58Confirmed
- Service 22
DID 905B - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 58 voltage ZOE_CELL1_V58
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 59 voltage ZOE_CELL_V59Confirmed
- Service 22
DID 905C - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 59 voltage ZOE_CELL1_V59
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 60 voltage ZOE_CELL_V60Confirmed
- Service 22
DID 905D - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 60 voltage ZOE_CELL1_V60
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 61 voltage ZOE_CELL_V61Confirmed
- Service 22
DID 905E - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 61 voltage ZOE_CELL1_V61
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 62 voltage ZOE_CELL_V62Confirmed
- Service 22
DID 905F - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 62 voltage ZOE_CELL1_V62
- Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 63 voltage ZOE_CELL_V63Confirmed
- Service 22
DID 9061 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 63 voltage ZOE_CELL1_V63
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 64 voltage ZOE_CELL_V64Confirmed
- Service 22
DID 9062 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 64 voltage ZOE_CELL1_V64
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 65 voltage ZOE_CELL_V65Confirmed
- Service 22
DID 9063 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 65 voltage ZOE_CELL1_V65
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 66 voltage ZOE_CELL_V66Confirmed
- Service 22
DID 9064 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 66 voltage ZOE_CELL1_V66
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 67 voltage ZOE_CELL_V67Confirmed
- Service 22
DID 9065 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 67 voltage ZOE_CELL1_V67
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 68 voltage ZOE_CELL_V68Confirmed
- Service 22
DID 9066 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 68 voltage ZOE_CELL1_V68
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 69 voltage ZOE_CELL_V69Confirmed
- Service 22
DID 9067 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 69 voltage ZOE_CELL1_V69
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 70 voltage ZOE_CELL_V70Confirmed
- Service 22
DID 9068 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 70 voltage ZOE_CELL1_V70
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 71 voltage ZOE_CELL_V71Confirmed
- Service 22
DID 9069 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 71 voltage ZOE_CELL1_V71
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 72 voltage ZOE_CELL_V72Confirmed
- Service 22
DID 906A - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 72 voltage ZOE_CELL1_V72
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 73 voltage ZOE_CELL_V73Confirmed
- Service 22
DID 906B - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 73 voltage ZOE_CELL1_V73
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 74 voltage ZOE_CELL_V74Confirmed
- Service 22
DID 906C - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 74 voltage ZOE_CELL1_V74
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 75 voltage ZOE_CELL_V75Confirmed
- Service 22
DID 906D - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 75 voltage ZOE_CELL1_V75
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 76 voltage ZOE_CELL_V76Confirmed
- Service 22
DID 906E - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 76 voltage ZOE_CELL1_V76
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 77 voltage ZOE_CELL_V77Confirmed
- Service 22
DID 906F - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 77 voltage ZOE_CELL1_V77
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 78 voltage ZOE_CELL_V78Confirmed
- Service 22
DID 9070 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 78 voltage ZOE_CELL1_V78
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 79 voltage ZOE_CELL_V79Confirmed
- Service 22
DID 9071 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 79 voltage ZOE_CELL1_V79
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 80 voltage ZOE_CELL_V80Confirmed
- Service 22
DID 9072 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 80 voltage ZOE_CELL1_V80
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 81 voltage ZOE_CELL_V81Confirmed
- Service 22
DID 9073 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 81 voltage ZOE_CELL1_V81
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 82 voltage ZOE_CELL_V82Confirmed
- Service 22
DID 9074 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 82 voltage ZOE_CELL1_V82
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 83 voltage ZOE_CELL_V83Confirmed
- Service 22
DID 9075 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 83 voltage ZOE_CELL1_V83
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 84 voltage ZOE_CELL_V84Confirmed
- Service 22
DID 9076 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 84 voltage ZOE_CELL1_V84
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 85 voltage ZOE_CELL_V85Confirmed
- Service 22
DID 9077 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 85 voltage ZOE_CELL1_V85
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 86 voltage ZOE_CELL_V86Confirmed
- Service 22
DID 9078 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 86 voltage ZOE_CELL1_V86
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 87 voltage ZOE_CELL_V87Confirmed
- Service 22
DID 9079 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 87 voltage ZOE_CELL1_V87
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 88 voltage ZOE_CELL_V88Confirmed
- Service 22
DID 907A - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 88 voltage ZOE_CELL1_V88
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 89 voltage ZOE_CELL_V89Confirmed
- Service 22
DID 907B - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 89 voltage ZOE_CELL1_V89
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 90 voltage ZOE_CELL_V90Confirmed
- Service 22
DID 907C - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 90 voltage ZOE_CELL1_V90
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 91 voltage ZOE_CELL_V91Confirmed
- Service 22
DID 907D - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 91 voltage ZOE_CELL1_V91
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 92 voltage ZOE_CELL_V92Confirmed
- Service 22
DID 907E - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 92 voltage ZOE_CELL1_V92
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 93 voltage ZOE_CELL_V93Confirmed
- Service 22
DID 907F - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 93 voltage ZOE_CELL1_V93
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 94 voltage ZOE_CELL_V94Confirmed
- Service 22
DID 9081 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 94 voltage ZOE_CELL1_V94
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 95 voltage ZOE_CELL_V95Confirmed
- Service 22
DID 9082 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 95 voltage ZOE_CELL1_V95
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Cell 96 voltage ZOE_CELL_V96Confirmed
- Service 22
DID 9083 - Module
DADB → DB - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cell 96 voltage ZOE_CELL1_V96
- Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Internal
Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Climate
A/C compressor discharge temperature ZOE_COMP_DIS_TConfirmed
- Service 22
DID 440C - Module
744 → 764 - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -30 to 32737.5 °C
- Unit
- °C
0x005A = 90 → = 15 °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
A/C compressor mode ZOE_COMP_MODEConfirmed
- Service 22
DID 4402 - Module
744 → 764 - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
0b0111 = 7 → IDLE
| Raw value | State | Meaning |
|---|---|---|
1 | AC | A/C |
2 | DEICE | De-ice |
4 | HEAT_PUMP | Heat pump |
6 | DEMIST | Demisting |
7 | IDLE | Idle |
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
A/C compressor power ZOE_COMP_PWRConfirmed
- Service 22
DID 4436 - Module
744 → 764 - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 W
- Unit
- W
0x0000 = 0 → = 0 W
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
A/C compressor pressure ZOE_COMP_PConfirmed
- Service 22
DID 4369 - Module
744 → 764 - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
0x002A = 42 → = 4.2 bar
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
A/C compressor speed ZOE_COMP_RPMConfirmed
- Service 22
DID 43D8 - Module
744 → 764 - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
A/C compressor speed request ZOE_COMP_RPM_REQConfirmed
- Service 22
DID 4404 - Module
744 → 764 - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
A/C compressor suction temperature ZOE_COMP_SUC_TConfirmed
- Service 22
DID 440D - Module
744 → 764 - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -30 to 32737.5 °C
- Unit
- °C
0x0068 = 104 → = 22 °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2020 to 2021. Supported for 2022.
Ambient air temperature ZOE_AATConfirmed
- Service 22
DID 2218 - Module
DADA → DA - Every
20 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280.5 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Cabin temperature ZOE_CABIN_TConfirmed
- Service 22
DID 4009 - Module
744 → 764 - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3316.8 to 3236.7 °C
- Unit
- °C
0x0201 = 513 → = 11.3 °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Electric heater request ZOE_PTC_REQConfirmed
- Service 22
DID 4341 - Module
744 → 764 - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 4 to 7 of the reply, 4 bits.
- Formula
- Range
- 0 to 15
- Unit
- Number
0b0000 = 0 → 0
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Evaporator temperature ZOE_EVAP_TConfirmed
- Service 22
DID 400A - Module
744 → 764 - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x024D = 589 → = 18.9 °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Evaporator temperature set point ZOE_EVAP_T_SETConfirmed
- Service 22
DID 4368 - Module
744 → 764 - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x03E4 = 996 → = 59.6 °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Heating condenser temperature ZOE_COND_TConfirmed
- Service 22
DID 4429 - Module
744 → 764 - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
0x3AEF = 15087 → = 18.933594 °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Heating condenser temperature set point ZOE_COND_T_SETConfirmed
- Service 22
DID 43A5 - Module
744 → 764 - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 87.998 °C
- Unit
- °C
0xE947 = 59719 → = 76.638672 °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Heating temperature ZOE_HEAT_T
- Service 22
DID 43A4 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2021. Supported for 2020, 2022.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2021. Supported for 2022.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2021. Supported for 2022.
Relative throttle position TP_RSAE J1979Confirmed
Relative or 'learned' throttle position.
- Service 01
PID 45 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2021. Supported for 2022.
Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2021. Supported for 2022.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2021. Supported for 2022.
Doors
Front left door open ZOE_FL_DOOR
- Service 22
DID 6026 - Module
745 → 765 - Every
3 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Front right door open ZOE_FR_DOOR
- Service 22
DID 6027 - Module
745 → 765 - Every
3 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Rear left door open ZOE_RL_DOOR
- Service 22
DID 61B2 - Module
745 → 765 - Every
3 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Rear right door open ZOE_RR_DOOR
- Service 22
DID 61B3 - Module
745 → 765 - Every
3 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Tailgate open ZOE_TAILGATE
- Service 22
DID 609B - Module
745 → 765 - Every
3 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Vehicle locked ZOE_LOCKED
- Service 22
DID 8004 - Module
745 → 765 - Every
3 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Drivetrain
Inverter high voltage ZOE_INV_HV_VConfirmed
- Service 22
DID 2004 - Module
DADF → DF - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.9687 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Inverter high voltage current ZOE_INV_HV_AConfirmed
- Service 22
DID 7049 - Module
DADF → DF - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -500 to 1547.9687 A
- Unit
- A
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Inverter state ZOE_INV_STATEConfirmed
- Service 22
DID 21CF - Module
DADA → DA - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OFF | Off |
2 | ON | On |
3 | DISCHARGING | Discharging |
4 | ALTERNATOR | Alternator mode |
5 | SLEEP_READY | Ready to sleep |
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Inverter temperature ZOE_INV_TConfirmed
- Service 22
DID 700C - Module
DADF → DF - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- -40 to 32727.998 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Inverter temperature, power electronics ZOE_INV_T_PEB
- Service 22
DID 33F6 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Motor speed ZOE_MOTOR_RPMConfirmed
- Service 22
DID 3064 - Module
DADA → DA - Every
1 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Rotor current sensor 1 ZOE_ROTOR_A1Confirmed
- Service 22
DID 7003 - Module
DADF → DF - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 A
- Unit
- A
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Rotor current sensor 2 ZOE_ROTOR_A2Confirmed
- Service 22
DID 7004 - Module
DADF → DF - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 A
- Unit
- A
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Rotor reference resistance ZOE_ROTOR_RConfirmed
- Service 22
DID 7050 - Module
DADF → DF - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 127.998 Ω
- Unit
- Ω
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Rotor temperature, estimated ZOE_ROTOR_TConfirmed
- Service 22
DID 7088 - Module
DADF → DF - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 471.9921 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Rotor temperature, raw ZOE_ROTOR_T_RAWConfirmed
- Service 22
DID 7038 - Module
DADF → DF - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 471.9921 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Stator current, phase U ZOE_STATOR_A_UConfirmed
- Service 22
DID 7007 - Module
DADF → DF - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -500 to 1547.9687 A
- Unit
- A
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Stator current, phase V ZOE_STATOR_A_VConfirmed
- Service 22
DID 7008 - Module
DADF → DF - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -500 to 1547.9687 A
- Unit
- A
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Stator current, phase W ZOE_STATOR_A_WConfirmed
- Service 22
DID 7009 - Module
DADF → DF - Every
5 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -500 to 1547.9687 A
- Unit
- A
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Stator temperature 1 ZOE_STATOR_T1Confirmed
- Service 22
DID 700F - Module
DADF → DF - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- -40 to 32727.998 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Stator temperature 2 ZOE_STATOR_T2Confirmed
- Service 22
DID 7010 - Module
DADF → DF - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- -40 to 32727.998 °C
- Unit
- °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2020 to 2021. Supported for 2022.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2020 to 2021. Supported for 2022.
Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed
Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.
- Service 01
PID 4E - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2020 to 2021. Supported for 2022.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2020 to 2021. Supported for 2022.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2020 to 2021. Supported for 2022.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2020 to 2021. Supported for 2022.
Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 4D - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2020 to 2021. Supported for 2022.
Status
A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2020, 2022.
A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2021. Supported for 2020, 2022.
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2020 to 2021. Supported for 2022.
Catalyst monitoring CAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2020, 2022.
Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2021. Supported for 2020, 2022.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2020 to 2021. Supported for 2022.
Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2021. Supported for 2020, 2022.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2020 to 2021. Supported for 2022.
EGR system monitoring EGR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2020, 2022.
EGR system monitoring completed EGR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2021. Supported for 2020, 2022.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2020 to 2021. Supported for 2022.
Evaporative system monitoring EVAP_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2020, 2022.
Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2021. Supported for 2020, 2022.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2020 to 2021. Supported for 2022.
Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2021. Supported for 2020, 2022.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2020 to 2021. Supported for 2022.
Heated catalyst monitoring HCAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2020, 2022.
Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2021. Supported for 2020, 2022.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2020 to 2021. Supported for 2022.
Misfire monitoring completed MIS_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2021. Supported for 2020, 2022.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2020 to 2021. Supported for 2022.
Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2020, 2022.
Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2021. Supported for 2020, 2022.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2020 to 2021. Supported for 2022.
Oxygen sensor monitoring O2S_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2020, 2022.
Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2021. Supported for 2020, 2022.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2020 to 2021. Supported for 2022.
Secondary air system monitoring AIR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2020, 2022.
Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2021. Supported for 2020, 2022.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2020 to 2021. Supported for 2022.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2020, 2022.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2020 to 2021. Supported for 2022.
Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2021. Supported for 2020, 2022.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2020, 2022.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Misfire monitoring enabled MIS_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021. Supported for 2020, 2022.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020 to 2021. Supported for 2022.
Electrical
12V battery current ZOE_12V_AConfirmed
- Service 22
DID 6079 - Module
74D → 76D - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 A
- Unit
- A
0x00A0 = 160 → = 16 A
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
12V battery voltage ZOE_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 2005 - Module
DADA → DA - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 V
- Unit
- V
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Engine
Absolute evap system vapor pressure EVAP_VPASAE J1979Confirmed
Normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Service 01
PID 53 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 327.675 kPa
- Unit
- kPa
Confirmed for 2020 to 2021. Supported for 2022.
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2020 to 2021. Supported for 2022.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2020 to 2021. Supported for 2022.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2021. Supported for 2022.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2020 to 2021. Supported for 2022.
Engine oil temperature EOTSAE J1979Confirmed
Pelican can show this parameter as the engine oil temperature.
- Service 01
PID 5C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2020 to 2021. Supported for 2022.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2020 to 2021. Supported for 2022.
Fuel pressure FPSAE J1979Confirmed
- Service 01
PID 0A - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 765 kPa
- Unit
- kPa
Confirmed for 2020 to 2021. Supported for 2022.
Fuel pressure relative to manifold vacuum FRP_RELSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to manifold vacuum (relative pressure).
- Service 01
PID 22 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5177.27 kPa
- Unit
- kPa
Confirmed for 2020 to 2021. Supported for 2022.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2020 to 2021. Supported for 2022.
Fuel rail pressure (absolute) FRP_ABSSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is absolute (referenced to vacuum). Meant for diesel and gasoline direct-injection systems, whose pressures exceed the range of PIDs 0A and 22.
- Service 01
PID 59 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2020 to 2021. Supported for 2022.
Ignition relay on ZOE_IGN
- Service 22
DID 60C6 - Module
745 → 765 - Every
3 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Intake air temperature IATSAE J1979Confirmed
- Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2020 to 2021. Supported for 2022.
Power take off (PTO) status PTO_STATSAE J1979Confirmed
- Service 01
PID 1E - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2020 to 2021. Supported for 2022.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2020 to 2021. Supported for 2022.
Fuel
Alcohol fuel percentage ALCH_PCTSAE J1979Confirmed
Indicates the percentage of alcohol contained in ethanol or methanol fuels, if used. For example, ethanol fuel (E85) normally contains 85% ethanol, in which case this parameter will display 85%
- Service 01
PID 52 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2021. Supported for 2022.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2020 to 2021. Supported for 2022.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2020 to 2021. Supported for 2022.
Lights
Low beams on ZOE_LOW_BEAM
- Service 22
DID 4186 - Module
745 → 765 - Every
3 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Movement
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2020 to 2021. Supported for 2022.
Vehicle speed ZOE_VSSConfirmed
Pelican can show this parameter as the speed.
- Service 22
DID 2003 - Module
DADA → DA - Every
1 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 km/h
- Unit
- km/h
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2021. Supported for 2020, 2022.
Tires
Front left tire pressure ZOE_TP_FLConfirmed
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 6300 - Module
745 → 765 - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 767.25 kPa
- Unit
- kPa
0x0127 = 295 → = 221.25 kPa
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Front left tire pressure alert ZOE_TP_FL_ALERT
- Service 22
DID 4109 - Module
745 → 765 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | ALERT | Alert |
2 | WARNING | Warning |
3 | ALERT | Alert |
4 | WARNING | Warning |
5 | ALERT | Alert |
6 | WARNING | Warning |
7 | ALERT | Alert |
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Front left tire temperature ZOE_TT_FLConfirmed
Pelican can show this parameter as the front left tire temperature.
- Service 22
DID 6310 - Module
745 → 765 - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -30 to 97 °C
- Unit
- °C
0x1C = 28 → = -2 °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Front right tire pressure ZOE_TP_FRConfirmed
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 6301 - Module
745 → 765 - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 767.25 kPa
- Unit
- kPa
0x0122 = 290 → = 217.5 kPa
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Front right tire pressure alert ZOE_TP_FR_ALERT
- Service 22
DID 410A - Module
745 → 765 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | ALERT | Alert |
2 | WARNING | Warning |
3 | ALERT | Alert |
4 | WARNING | Warning |
5 | ALERT | Alert |
6 | WARNING | Warning |
7 | ALERT | Alert |
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Front right tire temperature ZOE_TT_FRConfirmed
Pelican can show this parameter as the front right tire temperature.
- Service 22
DID 6311 - Module
745 → 765 - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -30 to 97 °C
- Unit
- °C
0x1D = 29 → = -1 °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Rear left tire pressure ZOE_TP_RLConfirmed
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 6302 - Module
745 → 765 - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 767.25 kPa
- Unit
- kPa
0x010B = 267 → = 200.25 kPa
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Rear left tire pressure alert ZOE_TP_RL_ALERT
- Service 22
DID 410B - Module
745 → 765 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | ALERT | Alert |
2 | WARNING | Warning |
3 | ALERT | Alert |
4 | WARNING | Warning |
5 | ALERT | Alert |
6 | WARNING | Warning |
7 | ALERT | Alert |
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Rear left tire temperature ZOE_TT_RLConfirmed
Pelican can show this parameter as the rear left tire temperature.
- Service 22
DID 6312 - Module
745 → 765 - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -30 to 97 °C
- Unit
- °C
0x1C = 28 → = -2 °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Rear right tire pressure ZOE_TP_RRConfirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 6303 - Module
745 → 765 - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 767.25 kPa
- Unit
- kPa
0x011D = 285 → = 213.75 kPa
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Rear right tire pressure alert ZOE_TP_RR_ALERT
- Service 22
DID 410C - Module
745 → 765 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | ALERT | Alert |
2 | WARNING | Warning |
3 | ALERT | Alert |
4 | WARNING | Warning |
5 | ALERT | Alert |
6 | WARNING | Warning |
7 | ALERT | Alert |
In testing for 2012 to 2020, 2022 to 2024. Not supported for 2021.
Rear right tire temperature ZOE_TT_RRConfirmed
Pelican can show this parameter as the rear right tire temperature.
- Service 22
DID 6313 - Module
745 → 765 - Every
60 s - Testing for 2012 to 2020, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -30 to 97 °C
- Unit
- °C
0x1B = 27 → = -3 °C
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Trips
Odometer ZOE_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 2006 - Module
DADA → DA - Every
10 s - Testing for 2012 to 2020, 2022 to 2024
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
Confirmed for 2021. In testing for 2012 to 2020, 2022 to 2024.
Odometer ZOE_ODO_CLUConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 0207 - Module
743 - Every
2 s - Testing for 2012 to 2019, 2022 to 2024
Example reply from a 2021 Renault Zoe.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x000000 = 0 → 0 km
Confirmed for 2020 to 2021. In testing for 2012 to 2014, 2016 to 2019, 2022 to 2024. Not supported for 2015.