Parameters
The Renault Scenic has 434 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Average voltage of cells SCENIC_AVG_V_CELLSConfirmed
- Service 22
DID 9006 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -30840 to 30840 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Battery voltage SCENIC_BAT_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 2006 - Module
743 → 763 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 V
- Unit
- V
0x0000 = 0 → = 0 V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Busbar voltage no. 1 SCENIC_BUSBAR_V_NO_1Confirmed
- Service 22
DID 9221 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32 to 31.99 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Busbar voltage no. 2 SCENIC_BUSBAR_V_NO_2Confirmed
- Service 22
DID 9222 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32 to 31.99 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Busbar voltage no. 3 SCENIC_BUSBAR_V_NO_3Confirmed
- Service 22
DID 9223 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32 to 31.99 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Busbar voltage no. 4 SCENIC_BUSBAR_V_NO_4Confirmed
- Service 22
DID 9224 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32 to 31.99 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Busbar voltage no. 5 SCENIC_BUSBAR_V_NO_5Confirmed
- Service 22
DID 9225 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32 to 31.99 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Busbar voltage no. 6 SCENIC_BUSBAR_V_NO_6Confirmed
- Service 22
DID 9226 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32 to 31.99 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Busbar voltage no. 7 SCENIC_BUSBAR_V_NO_7Confirmed
- Service 22
DID 9227 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32 to 31.99 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Busbar voltage no. 8 SCENIC_BUSBAR_V_NO_8Confirmed
- Service 22
DID 9228 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32 to 31.99 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell overvoltage SCENIC_CELLS_OVERVOLTAGEConfirmed
- Service 22
DID 9216 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell with the highest voltage SCENIC_CELL_HIGHEST_VConfirmed
- Service 22
DID 9008 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell with the lowest voltage SCENIC_CELL_LOWEST_VConfirmed
- Service 22
DID 900A - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cells undervoltage SCENIC_CELLS_UNDERVOLTAGEConfirmed
- Service 22
DID 9216 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Complete charge cycles SCENIC_CYCLESConfirmed
- Service 22
DID 9210 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Computer supply voltage SCENIC_ECU_V
- Service 22
DID 012F - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 V
- Unit
- V
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2018.
Energy charged, total SCENIC_E_CHGConfirmed
- Service 22
DID 9243 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967.295 kWh
- Unit
- kWh
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Energy discharged, total SCENIC_E_DISCHGConfirmed
- Service 22
DID 9245 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967.295 kWh
- Unit
- kWh
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Energy regenerated, total SCENIC_E_REGENConfirmed
- Service 22
DID 9247 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967.295 kWh
- Unit
- kWh
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
High voltage battery available energy SCENIC_HV_E_AVAILConfirmed
- Service 22
DID 91C8 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777.215 kWh
- Unit
- kWh
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
High voltage battery average temperature SCENIC_HV_TConfirmed
- Service 22
DID 9012 - Module
DADB → DB - Every
10 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
High voltage battery current, raw SCENIC_HV_A_3042_RAWConfirmed
- Service 22
DID 3042 - Module
DADA → DA - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
High voltage battery voltage SCENIC_HV_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 9005 - Module
DADB → DB - Every
2 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Highest cell voltage level SCENIC_HIGHEST_CELL_V_LEVELConfirmed
- Service 22
DID 9007 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.99 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023, 2025.
Lowest cell voltage level SCENIC_LOWEST_CELL_V_LEVELConfirmed
- Service 22
DID 9009 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.99 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Maximum charge power SCENIC_CHG_P_MAXConfirmed
- Service 22
DID 9018 - Module
DADB → DB - Every
10 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 kW
- Unit
- kW
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pack temperature 1 SCENIC_PACK_T1Confirmed
- Service 22
DID 9131 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pack temperature 2 SCENIC_PACK_T2Confirmed
- Service 22
DID 9132 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pack temperature 3 SCENIC_PACK_T3Confirmed
- Service 22
DID 9133 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pack temperature 4 SCENIC_PACK_T4Confirmed
- Service 22
DID 9134 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pack temperature 5 SCENIC_PACK_T5Confirmed
- Service 22
DID 9135 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pack temperature 6 SCENIC_PACK_T6Confirmed
- Service 22
DID 9136 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pack temperature 7 SCENIC_PACK_T7Confirmed
- Service 22
DID 9137 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pack temperature 8 SCENIC_PACK_T8Confirmed
- Service 22
DID 9138 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pack temperature 9 SCENIC_PACK_T9Confirmed
- Service 22
DID 9139 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pack temperature 10 SCENIC_PACK_T10Confirmed
- Service 22
DID 913A - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pack temperature 11 SCENIC_PACK_T11Confirmed
- Service 22
DID 913B - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pack temperature 12 SCENIC_PACK_T12Confirmed
- Service 22
DID 913C - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055.9375 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
State of charge SCENIC_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID 9002 - Module
DADB → DB - Every
10 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
State of charge, battery controller SCENIC_SOC_9001Confirmed
- Service 22
DID 9001 - Module
DADB → DB - Every
10 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
State of health SCENIC_SOHConfirmed
Pelican can show this parameter as the state of health.
- Service 22
DID 9003 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Supply voltage, ECU SCENIC_ECU_SUPPLY_V
- Service 22
DID 2005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 V
- Unit
- V
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Traction battery input water temperature SCENIC_TRACTION_BAT_INPUT_TConfirmed
- Service 22
DID 91CD - Module
DADB → DB - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Traction battery interlock SCENIC_TRACTION_BAT_INTERLOCKConfirmed
- Service 22
DID 91F7 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Traction battery max temperature SCENIC_TRACTION_BAT_MAX_TConfirmed
- Service 22
DID 9014 - Module
DADB → DB - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Traction battery min. temperature SCENIC_TRACTION_BAT_MIN_TConfirmed
- Service 22
DID 9013 - Module
DADB → DB - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 4055 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Traction battery overcurrent SCENIC_TRACTION_BAT_OVERCURRENTConfirmed
- Service 22
DID 9216 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Traction battery overheating SCENIC_TRACTION_BATConfirmed
- Service 22
DID 9216 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Traction battery service plug interlock SCENIC_TRACTION_BAT_SERVICEConfirmed
- Service 22
DID 91F6 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Traction battery total mileage SCENIC_TRACTION_BAT_TOTConfirmed
- Service 22
DID 91CF - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- 0 to 134217727 km
- Unit
- km
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Traction battery, current SCENIC_TRACTION_BAT_CURRENTConfirmed
- Service 22
DID 9284 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483 to 2147483 A
- Unit
- A
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cells
Cell 1 voltage SCENIC_CELL_V1Confirmed
- Service 22
DID 9021 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 2 voltage SCENIC_CELL_V2Confirmed
- Service 22
DID 9022 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 3 voltage SCENIC_CELL_V3Confirmed
- Service 22
DID 9023 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 4 voltage SCENIC_CELL_V4Confirmed
- Service 22
DID 9024 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 5 voltage SCENIC_CELL_V5Confirmed
- Service 22
DID 9025 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 6 voltage SCENIC_CELL_V6Confirmed
- Service 22
DID 9026 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 7 voltage SCENIC_CELL_V7Confirmed
- Service 22
DID 9027 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 8 voltage SCENIC_CELL_V8Confirmed
- Service 22
DID 9028 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 9 voltage SCENIC_CELL_V9Confirmed
- Service 22
DID 9029 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 10 voltage SCENIC_CELL_V10Confirmed
- Service 22
DID 902A - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 11 voltage SCENIC_CELL_V11Confirmed
- Service 22
DID 902B - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 12 voltage SCENIC_CELL_V12Confirmed
- Service 22
DID 902C - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 13 voltage SCENIC_CELL_V13Confirmed
- Service 22
DID 902D - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 14 voltage SCENIC_CELL_V14Confirmed
- Service 22
DID 902E - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 15 voltage SCENIC_CELL_V15Confirmed
- Service 22
DID 902F - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 16 voltage SCENIC_CELL_V16Confirmed
- Service 22
DID 9030 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 17 voltage SCENIC_CELL_V17Confirmed
- Service 22
DID 9031 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 18 voltage SCENIC_CELL_V18Confirmed
- Service 22
DID 9032 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 19 voltage SCENIC_CELL_V19Confirmed
- Service 22
DID 9033 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 20 voltage SCENIC_CELL_V20Confirmed
- Service 22
DID 9034 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 21 voltage SCENIC_CELL_V21Confirmed
- Service 22
DID 9035 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 22 voltage SCENIC_CELL_V22Confirmed
- Service 22
DID 9036 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 23 voltage SCENIC_CELL_V23Confirmed
- Service 22
DID 9037 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 24 voltage SCENIC_CELL_V24Confirmed
- Service 22
DID 9038 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 25 voltage SCENIC_CELL_V25Confirmed
- Service 22
DID 9039 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 26 voltage SCENIC_CELL_V26Confirmed
- Service 22
DID 903A - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 27 voltage SCENIC_CELL_V27Confirmed
- Service 22
DID 903B - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 28 voltage SCENIC_CELL_V28Confirmed
- Service 22
DID 903C - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 29 voltage SCENIC_CELL_V29Confirmed
- Service 22
DID 903D - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 30 voltage SCENIC_CELL_V30Confirmed
- Service 22
DID 903E - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 31 voltage SCENIC_CELL_V31Confirmed
- Service 22
DID 903F - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 32 voltage SCENIC_CELL_V32Confirmed
- Service 22
DID 9041 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 33 voltage SCENIC_CELL_V33Confirmed
- Service 22
DID 9042 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 34 voltage SCENIC_CELL_V34Confirmed
- Service 22
DID 9043 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 35 voltage SCENIC_CELL_V35Confirmed
- Service 22
DID 9044 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 36 voltage SCENIC_CELL_V36Confirmed
- Service 22
DID 9045 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 37 voltage SCENIC_CELL_V37Confirmed
- Service 22
DID 9046 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 38 voltage SCENIC_CELL_V38Confirmed
- Service 22
DID 9047 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 39 voltage SCENIC_CELL_V39Confirmed
- Service 22
DID 9048 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 40 voltage SCENIC_CELL_V40Confirmed
- Service 22
DID 9049 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 41 voltage SCENIC_CELL_V41Confirmed
- Service 22
DID 904A - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 42 voltage SCENIC_CELL_V42Confirmed
- Service 22
DID 904B - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 43 voltage SCENIC_CELL_V43Confirmed
- Service 22
DID 904C - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 44 voltage SCENIC_CELL_V44Confirmed
- Service 22
DID 904D - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 45 voltage SCENIC_CELL_V45Confirmed
- Service 22
DID 904E - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 46 voltage SCENIC_CELL_V46Confirmed
- Service 22
DID 904F - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 47 voltage SCENIC_CELL_V47Confirmed
- Service 22
DID 9050 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 48 voltage SCENIC_CELL_V48Confirmed
- Service 22
DID 9051 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 49 voltage SCENIC_CELL_V49Confirmed
- Service 22
DID 9052 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 50 voltage SCENIC_CELL_V50Confirmed
- Service 22
DID 9053 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 51 voltage SCENIC_CELL_V51Confirmed
- Service 22
DID 9054 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 52 voltage SCENIC_CELL_V52Confirmed
- Service 22
DID 9055 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 53 voltage SCENIC_CELL_V53Confirmed
- Service 22
DID 9056 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 54 voltage SCENIC_CELL_V54Confirmed
- Service 22
DID 9057 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 55 voltage SCENIC_CELL_V55Confirmed
- Service 22
DID 9058 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 56 voltage SCENIC_CELL_V56Confirmed
- Service 22
DID 9059 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 57 voltage SCENIC_CELL_V57Confirmed
- Service 22
DID 905A - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 58 voltage SCENIC_CELL_V58Confirmed
- Service 22
DID 905B - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 59 voltage SCENIC_CELL_V59Confirmed
- Service 22
DID 905C - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 60 voltage SCENIC_CELL_V60Confirmed
- Service 22
DID 905D - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 61 voltage SCENIC_CELL_V61Confirmed
- Service 22
DID 905E - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 62 voltage SCENIC_CELL_V62Confirmed
- Service 22
DID 905F - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 63 voltage SCENIC_CELL_V63Confirmed
- Service 22
DID 9061 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 64 voltage SCENIC_CELL_V64Confirmed
- Service 22
DID 9062 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 65 voltage SCENIC_CELL_V65Confirmed
- Service 22
DID 9063 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 66 voltage SCENIC_CELL_V66Confirmed
- Service 22
DID 9064 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 67 voltage SCENIC_CELL_V67Confirmed
- Service 22
DID 9065 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 68 voltage SCENIC_CELL_V68Confirmed
- Service 22
DID 9066 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 69 voltage SCENIC_CELL_V69Confirmed
- Service 22
DID 9067 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 70 voltage SCENIC_CELL_V70Confirmed
- Service 22
DID 9068 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 71 voltage SCENIC_CELL_V71Confirmed
- Service 22
DID 9069 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 72 voltage SCENIC_CELL_V72Confirmed
- Service 22
DID 906A - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 73 voltage SCENIC_CELL_V73Confirmed
- Service 22
DID 906B - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 74 voltage SCENIC_CELL_V74Confirmed
- Service 22
DID 906C - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 75 voltage SCENIC_CELL_V75Confirmed
- Service 22
DID 906D - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 76 voltage SCENIC_CELL_V76Confirmed
- Service 22
DID 906E - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 77 voltage SCENIC_CELL_V77Confirmed
- Service 22
DID 906F - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 78 voltage SCENIC_CELL_V78Confirmed
- Service 22
DID 9070 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 79 voltage SCENIC_CELL_V79Confirmed
- Service 22
DID 9071 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 80 voltage SCENIC_CELL_V80Confirmed
- Service 22
DID 9072 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 81 voltage SCENIC_CELL_V81Confirmed
- Service 22
DID 9073 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 82 voltage SCENIC_CELL_V82Confirmed
- Service 22
DID 9074 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 83 voltage SCENIC_CELL_V83Confirmed
- Service 22
DID 9075 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 84 voltage SCENIC_CELL_V84Confirmed
- Service 22
DID 9076 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 85 voltage SCENIC_CELL_V85Confirmed
- Service 22
DID 9077 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 86 voltage SCENIC_CELL_V86Confirmed
- Service 22
DID 9078 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 87 voltage SCENIC_CELL_V87Confirmed
- Service 22
DID 9079 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 88 voltage SCENIC_CELL_V88Confirmed
- Service 22
DID 907A - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 89 voltage SCENIC_CELL_V89Confirmed
- Service 22
DID 907B - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 90 voltage SCENIC_CELL_V90Confirmed
- Service 22
DID 907C - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 91 voltage SCENIC_CELL_V91Confirmed
- Service 22
DID 907D - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 92 voltage SCENIC_CELL_V92Confirmed
- Service 22
DID 907E - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 93 voltage SCENIC_CELL_V93Confirmed
- Service 22
DID 907F - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 94 voltage SCENIC_CELL_V94Confirmed
- Service 22
DID 9081 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 95 voltage SCENIC_CELL_V95Confirmed
- Service 22
DID 9082 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Cell 96 voltage SCENIC_CELL_V96Confirmed
- Service 22
DID 9083 - Module
DADB → DB - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Climate
A/C compressor SCENIC_AC_COMP
- Service 22
DID 201E - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
A/C compressor discharge temperature SCENIC_COMP_DIS_TConfirmed
- Service 22
DID 440C - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -30 to 32737.5 °C
- Unit
- °C
0x003C = 60 → = 0 °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
A/C compressor mode SCENIC_COMP_MODE
- Service 22
DID 4402 - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | AC | A/C |
2 | DEICE | De-ice |
4 | HEAT_PUMP | Heat pump |
6 | DEMIST | Demisting |
7 | IDLE | Idle |
In testing for 1996 to 2022, 2024 to 2026. Supported for 2023.
A/C compressor power SCENIC_COMP_PWRConfirmed
- Service 22
DID 4436 - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 W
- Unit
- W
0x0000 = 0 → = 0 W
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
A/C compressor pressure SCENIC_COMP_PConfirmed
- Service 22
DID 4369 - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
0x002C = 44 → = 4.4 bar
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
A/C compressor speed SCENIC_COMP_RPMConfirmed
- Service 22
DID 43D8 - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
A/C compressor speed request SCENIC_COMP_RPM_REQConfirmed
- Service 22
DID 4404 - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
A/C compressor suction temperature SCENIC_COMP_SUC_TConfirmed
- Service 22
DID 440D - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -30 to 32737.5 °C
- Unit
- °C
0x0050 = 80 → = 10 °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018.
Cabin temperature SCENIC_CABIN_TConfirmed
- Service 22
DID 4009 - Module
744 → 764 - Every
10 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3316.8 to 3236.7 °C
- Unit
- °C
0x025E = 606 → = 20.6 °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Electric heater request SCENIC_PTC_REQConfirmed
- Service 22
DID 4341 - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 4 to 7 of the reply, 4 bits.
- Formula
- Range
- 0 to 15
- Unit
- Number
0b0000 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Evaporator temperature SCENIC_EVAP_TConfirmed
- Service 22
DID 400A - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x01AD = 429 → = 2.9 °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Evaporator temperature set point SCENIC_EVAP_T_SETConfirmed
- Service 22
DID 4368 - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x01B3 = 435 → = 3.5 °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Heating condenser temperature SCENIC_COND_TConfirmed
- Service 22
DID 4429 - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
0x0000 = 0 → = -40 °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Heating condenser temperature set point SCENIC_COND_T_SETConfirmed
- Service 22
DID 43A5 - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 87.998 °C
- Unit
- °C
0x0000 = 0 → = -40 °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Heating temperature, raw SCENIC_HEAT_T_RAWConfirmed
- Service 22
DID 43A4 - Module
744 → 764 - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Refrigerant pressure SCENIC_REFRIG_P
- Service 22
DID 222A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Refrigerant pressure sensor voltage SCENIC_REFRIG_P_SNS_V
- Service 22
DID 200D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 V
- Unit
- V
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2018.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2006 to 2007.
Brake contact duration 1 SCENIC_BRAKE_CONTACT_1_DUR
- Service 22
DID 206A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Brake contact duration 2 SCENIC_BRAKE_CONTACT_2_DUR
- Service 22
DID 206B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Brake contact, wired SCENIC_WIRED_BRAKE_CONTACT
- Service 22
DID 2026 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Brake dive limiter SCENIC_BRAKE_DIVE
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 32 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Brake dive limiter, warning SCENIC_BRAKE_DIVE_WARN
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 33 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Brake lights request SCENIC_BRAKE_LIGHTS
- Service 22
DID 4B15 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Brake pedal SCENIC_BRAKE_PEDAL
- Service 22
DID 4B11 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Brake pedal SCENIC_BRAKE_PEDAL_ECM
- Service 22
DID 2025 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Brake pressure, master cylinder SCENIC_BRAKE_P_MC
- Service 22
DID 4B0E - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 bar
- Unit
- bar
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Braking detected multiplex signal SCENIC_BRAKE_MUX_SIG
- Service 22
DID 200F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Parking brake SCENIC_PARK_BRAKE
- Service 22
DID 4B27 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Relative throttle position TP_RSAE J1979Confirmed
Relative or 'learned' throttle position.
- Service 01
PID 45 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Steering wheel angle SCENIC_STEER_WHL_ANG_742Confirmed
- Service 22
DID 0104 - Module
742 - Every
250 ms - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
0x7FFF = 32767 → = 0 °
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Steering wheel speed SCENIC_STEER_WHL_SPD_CALCConfirmed
- Service 22
DID 0101 - Module
742 - Every
250 ms - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
0x7FF8 = 32760 → = -0.7
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Doors
Front left door open SCENIC_FL_DOORConfirmed
- Service 22
DID 6026 - Module
745 → 765 - Every
3 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Front right door open SCENIC_FR_DOORConfirmed
- Service 22
DID 6027 - Module
745 → 765 - Every
3 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rear left door open SCENIC_RL_DOORConfirmed
- Service 22
DID 61B2 - Module
745 → 765 - Every
3 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rear right door open SCENIC_RR_DOORConfirmed
- Service 22
DID 61B3 - Module
745 → 765 - Every
3 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Tailgate open SCENIC_TAILGATEConfirmed
- Service 22
DID 609B - Module
745 → 765 - Every
3 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Vehicle locked SCENIC_LOCKEDConfirmed
- Service 22
DID 8004 - Module
745 → 765 - Every
3 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Drivetrain
Driving type SCENIC_DRIVE_TYPE
- Service 22
DID 4B3C - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Inverter high voltage SCENIC_INV_HV_VConfirmed
- Service 22
DID 2004 - Module
DADF → DF - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.9687 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Inverter high voltage current, raw SCENIC_INV_HV_A_RAWConfirmed
- Service 22
DID 7049 - Module
DADF → DF - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483648 to 2147483647
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Inverter temperature, raw SCENIC_INV_T_RAWConfirmed
- Service 22
DID 700C - Module
DADF → DF - Every
10 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483648 to 2147483647
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Motor speed SCENIC_MOTOR_RPMConfirmed
- Service 22
DID 3064 - Module
DADA → DA - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rotor current sensor 1 SCENIC_ROTOR_A1Confirmed
- Service 22
DID 7003 - Module
DADF → DF - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 A
- Unit
- A
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rotor current sensor 2 SCENIC_ROTOR_A2Confirmed
- Service 22
DID 7004 - Module
DADF → DF - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.999 A
- Unit
- A
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rotor reference resistance SCENIC_ROTOR_RConfirmed
- Service 22
DID 7050 - Module
DADF → DF - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 127.998 Ω
- Unit
- Ω
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Stator current, phase U, raw SCENIC_STATOR_A_U_RAWConfirmed
- Service 22
DID 7007 - Module
DADF → DF - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483648 to 2147483647
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Stator current, phase V, raw SCENIC_STATOR_A_V_RAWConfirmed
- Service 22
DID 7008 - Module
DADF → DF - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483648 to 2147483647
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Stator current, phase W, raw SCENIC_STATOR_A_W_RAWConfirmed
- Service 22
DID 7009 - Module
DADF → DF - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483648 to 2147483647
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Stator temperature 1, raw SCENIC_STATOR_T1_RAWConfirmed
- Service 22
DID 700F - Module
DADF → DF - Every
10 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483648 to 2147483647
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2018.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2018. Supported for 2006 to 2007.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018. Supported for 2006 to 2007.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2018. Supported for 2006 to 2007.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018.
Status
A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018.
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2006 to 2007.
Catalyst monitoring CAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2006 to 2007.
Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2006 to 2007.
EGR system monitoring EGR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
EGR system monitoring completed EGR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2006 to 2007.
Evaporative system monitoring EVAP_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2006 to 2007.
Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2006 to 2007.
Heated catalyst monitoring HCAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2006 to 2007.
Misfire monitoring completed MIS_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2006 to 2007.
Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2006 to 2007.
Oxygen sensor monitoring O2S_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2006 to 2007.
Secondary air system monitoring AIR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2006 to 2007.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2018. Supported for 2006 to 2007.
Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2018.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
Misfire monitoring enabled MIS_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
ECU
Fault counter SCENIC_FAULT_CNT
- Service 22
DID 4B05 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Fault cycles since disappeared SCENIC_FAULT_CYCLES
- Service 22
DID 4B08 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Supplier number SCENIC_SUPPLIER_NUM
- Service 22
DID 4B3D - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Electrical
Alternator load SCENIC_ALT_LOAD
- Service 22
DID 2099 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Alternator power SCENIC_ALT_PWR
- Service 22
DID 2057 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 W
- Unit
- W
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Hazard lights LED SCENIC_HAZARD_LED
- Service 22
DID 4B14 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Sensor feed voltage 1 SCENIC_SNS_FEED_V1
- Service 22
DID 2021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Sensor feed voltage 2 SCENIC_SNS_FEED_V2
- Service 22
DID 2022 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Engine
ABS, warning SCENIC_ABS_WARN
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Absolute time since first ignition SCENIC_ABS_TIME_SINCE_FIRSTConfirmed
- Service 22
DID 9261 - Module
DADB → DB - Every
30 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Accelerator pedal detection blocked SCENIC_ACCEL_DETECT_BLOCKED
- Service 22
DID 2036 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Accelerator pedal potentiometer voltage, track 1 SCENIC_ACCEL_POT_V1
- Service 22
DID 200B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Accelerator pedal potentiometer voltage, track 2 SCENIC_ACCEL_POT_V2
- Service 22
DID 200C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2018.
Air inlet temperature sensor voltage SCENIC_AIR_INLET_T_SNS_V
- Service 22
DID FD83 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.99975 V
- Unit
- V
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Anti-lock braking SCENIC_ABS
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Anti-rollover control SCENIC_ANTI_ROLL
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Anti-rollover control, warning SCENIC_ANTI_ROLL_WARN
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2018.
Boost pressure SCENIC_BOOST_P
- Service 22
DID 2401 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2006 to 2007.
Camshaft top dead center synchronization SCENIC_CAM_TDC_SYNC
- Service 22
DID 2014 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Canister bleed solenoid valve RCO SCENIC_CANISTER_BLEED_SOL_RCO
- Service 22
DID 2822 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2018.
Catalyst temperature bank 1, sensor 2 CATEMP12SAE J1979Confirmed
- Service 01
PID 3E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2018.
Clutch contact wire connection SCENIC_CLUTCH_CONTACT_WIRE
- Service 22
DID 206D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Clutch pedal switch SCENIC_CLUTCH_PEDAL_SW
- Service 22
DID 222D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Clutch start-of-travel switch SCENIC_CLUTCH_TRAVEL_SW
- Service 22
DID 2059 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Computer power supply SCENIC_COMPUTER_POWER_SUPConfirmed
- Service 22
DID 9011 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.99 V
- Unit
- V
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Consumption measurement units SCENIC_E_CONS_MEASUREMENTConfirmed
- Service 22
DID 0105 - Module
743 → 763 - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 6 to 7 of the reply, 2 bits.
- Formula
- Range
- 0 to 3
- Unit
- Number
0b01 = 1 → 1
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Coolant temperature SCENIC_ECT
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 2001 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280.5 °C
- Unit
- °C
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Coolant temperature sensor voltage SCENIC_COOLANT_T_SNS_V
- Service 22
DID FD8B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.99975 V
- Unit
- V
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Crankshaft sync loss counter SCENIC_CRANK_SYNC_LOSS_CNT
- Service 22
DID 2162 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Crankshaft synchronization SCENIC_CRANK_SYNC
- Service 22
DID 2016 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
EGR error EGR_ERRSAE J1979Confirmed
- Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2018.
Electronic brakeforce distribution SCENIC_EBD
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Electronic brakeforce distribution, warning SCENIC_EBD_WARN
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Emergency braking anticipation SCENIC_EBA_ANT
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Emergency braking anticipation, warning SCENIC_EBA_ANT_WARN
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Emergency braking assistance SCENIC_EBA_ASSIST
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Emergency braking assistance, warning SCENIC_EBA_ASSIST_WARN
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. Supported for 2006 to 2007.
Engine oil temperature EOTSAE J1979Confirmed
Pelican can show this parameter as the engine oil temperature.
- Service 01
PID 5C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018.
Engine oil temperature, estimated SCENIC_EST_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 2007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280.5 °C
- Unit
- °C
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Engine rotation count SCENIC_ENGINE_ROT_COUNT
- Service 22
DID 210E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294.967295
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2018. Supported for 2006 to 2007.
Engine torque SCENIC_ENGINE_TORQUE
- Service 22
DID 2004 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -400 to 1647.96875 N·m
- Unit
- N·m
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Engine torque control SCENIC_TORQUE_CTRL
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Engine torque control, warning SCENIC_TORQUE_CTRL_WARN
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
ESP, deactivated SCENIC_ESP_OFF
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Fan unit SCENIC_FAN_UNIT
- Service 22
DID 91EF - Module
DADB → DB - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.
Fan unit feed SCENIC_FAN_UNIT_FEED
- Service 22
DID 925A - Module
DADB → DB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 Hz
- Unit
- Hz
In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.
Fault finding version SCENIC_FAULT_FINDINGConfirmed
- Service 22
DID F1A0 - Module
DADB → DB - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
First start SCENIC_FIRST_START
- Service 22
DID 2047 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Fuel level, low SCENIC_LOW_FUEL
- Service 22
DID 281B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Fuel pump control circuit SCENIC_FUEL_PUMP_CTRL
- Service 22
DID 281C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2018.
Hill start assist SCENIC_HILL_START
- Service 22
DID 4B31 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Hydraulic unit temperature SCENIC_HYD_T
- Service 22
DID 4B17 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Idle adaptive correction SCENIC_IDLE_ADAPT_CORR
- Service 22
DID 209A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1024 to 1023.96875 N·m
- Unit
- N·m
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Idle regulation integral correction SCENIC_IDLE_REG_INT_CORR
- Service 22
DID 2246 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1024 to 1023.96875 N·m
- Unit
- N·m
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Ignition relay on SCENIC_IGNConfirmed
- Service 22
DID 60C6 - Module
745 → 765 - Every
3 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Ignition timing advance SCENIC_IGN_TIMING_ADV
- Service 22
DID 2807 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Improved grip SCENIC_GRIP_CTRL
- Service 22
DID 4B47 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Inlet air temperature SCENIC_INLET_AIR_T
- Service 22
DID 243F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280.5 °C
- Unit
- °C
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Inlet camshaft dephaser control OCR SCENIC_IN_CAM_DEPHASER_OCR
- Service 22
DID 2033 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Inlet camshaft dephaser setpoint SCENIC_IN_CAM_DEPHASER_SETPT
- Service 22
DID 2030 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 °
- Unit
- °
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Inlet camshaft dephaser solenoid programming SCENIC_IN_CAM_DEPHASER_SOL_PROG
- Service 22
DID 2241 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Inlet camshaft dephasing SCENIC_IN_CAM_DEPHASING
- Service 22
DID 2031 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 °
- Unit
- °
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Intake air temperature IATSAE J1979Confirmed
- Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. Supported for 2006 to 2007.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2018. Supported for 2006 to 2007.
Liquefied petroleum gas pressure SCENIC_LPG_P
- Service 22
DID F423 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Maintenance autonomy interval in days SCENIC_E_MAINTENANCE_AUTONOMY_INTERVAL_DAYSConfirmed
- Service 22
DID 020C - Module
743 → 763 - Every
3600 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
0x712A = 28970 → 28,970
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Maintenance autonomy/current value days SCENIC_E_MAINTENANCE_AUTONOMY_CURRENT_DAYSConfirmed
- Service 22
DID 020E - Module
743 → 763 - Every
3600 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
0x0000 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Maintenance autonomy/current value in km SCENIC_E_MAINTENANCE_AUTONOMY_CURRENT_KMConfirmed
- Service 22
DID 020D - Module
743 → 763 - Every
3600 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 40720 mi
- Unit
- mi
0x0168 = 360 → = 223.68932 mi
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Manifold pressure SCENIC_MANIFOLD_P
- Service 22
DID 240B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 kPa
- Unit
- kPa
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Manifold pressure sensor voltage SCENIC_MANIFOLD_P_SNS_V
- Service 22
DID FD81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.99975 V
- Unit
- V
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Manifold pressure, linearised SCENIC_MANIFOLD_P_LIN
- Service 22
DID 24D7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Measured air flow SCENIC_MAF
Pelican can show this parameter as the mass air flow.
- Service 22
DID 24F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 g/s
- Unit
- g/s
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Misfire counter, total SCENIC_MISFIRE_CNT
- Service 22
DID 2874 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Module with, minimum temperature SCENIC_MODULE_MIN_TConfirmed
- Service 22
DID 9242 - Module
DADB → DB - Every
5 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Motor status SCENIC_MOTOR
- Service 22
DID 2010 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Motor-driven fan unit request SCENIC_MOTOR_DRIVEN_FAN
- Service 22
DID 91C9 - Module
DADB → DB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.
O2 sensor heating resistance, downstream SCENIC_O2_DN_HEAT_R
- Service 22
DID 244C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 Ω
- Unit
- Ω
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
O2 sensor heating resistance, upstream SCENIC_O2_UP_HEAT_R
- Service 22
DID 244B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 Ω
- Unit
- Ω
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
O2 sensor voltage, downstream SCENIC_O2_DN_V
- Service 22
DID 244A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
O2 sensor voltage, upstream SCENIC_O2_UP_V
- Service 22
DID 2449 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Oil change frequency in days SCENIC_E_OIL_CHANGE_FREQUENCYConfirmed
- Service 22
DID 0202 - Module
743 → 763 - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
0x0000 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Oil change interval in km SCENIC_E_OIL_CHANGE_INTERVAL_KMConfirmed
- Service 22
DID 0201 - Module
743 → 763 - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 40720 mi
- Unit
- mi
0x0000 = 0 → = 0 mi
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Oil service interval in days SCENIC_E_OIL_SERVICE_INTERVALConfirmed
- Service 22
DID 0204 - Module
743 → 763 - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
0x0000 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Post-ignition status SCENIC_ECU_POST_IGN
- Service 22
DID 200E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Power take off (PTO) status PTO_STATSAE J1979Confirmed
- Service 01
PID 1E - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018.
Pressure sensor offset SCENIC_P_SNS_OFFSET
- Service 22
DID 4B39 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 bar
- Unit
- bar
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Richness correction SCENIC_RICHNESS_CORR
- Service 22
DID 284E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Test result 1 SCENIC_TEST_RESULT_1
- Service 22
DID 2493 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Test result 2 SCENIC_TEST_RESULT_2
- Service 22
DID 2494 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Throttle limits programming SCENIC_THROTTLE_LIMITS_PROG
- Service 22
DID 245D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Throttle low stop, programmed SCENIC_THROTTLE_LOW_STOP_PROG
- Service 22
DID 2457 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 %
- Unit
- %
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Throttle position, measured SCENIC_THROTTLE_POS
- Service 22
DID 242F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 %
- Unit
- %
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Throttle position, reference SCENIC_THROTTLE_POS_REF
- Service 22
DID 2414 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 %
- Unit
- %
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Throttle position, track 1 SCENIC_THROTTLE_POS_1
- Service 22
DID 2415 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 %
- Unit
- %
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Throttle position, track 2 SCENIC_THROTTLE_POS_2
- Service 22
DID 2416 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 %
- Unit
- %
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Throttle safe mode value, programmed SCENIC_THROTTLE_SAFE_MODE_PROG
- Service 22
DID 24C9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 %
- Unit
- %
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Throttle voltage, track 1 SCENIC_THROTTLE_V1
- Service 22
DID 2418 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Throttle voltage, track 2 SCENIC_THROTTLE_V2
- Service 22
DID 2419 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Top dead center sensor signal SCENIC_TDC_SNS_SIG
- Service 22
DID 2161 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Traction control SCENIC_TC
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Traction control, deactivated SCENIC_TC_OFF
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Traction control, warning SCENIC_TC_WARN
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Trailer stability SCENIC_TRAILER_STAB
- Service 22
DID 4B2E - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Trajectory control SCENIC_TRAJ_CTRL
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Trajectory control, warning SCENIC_TRAJ_CTRL_WARN
- Service 22
DID 4B35 - Module
740 → 760 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Trip computer display type SCENIC_E_ADAC_DISPLAY_TYPEConfirmed
- Service 22
DID 0106 - Module
743 → 763 - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 6 to 7 of the reply, 2 bits.
- Formula
- Range
- 0 to 3
- Unit
- Number
0b10 = 2 → 2
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Vacuum sensor pressure SCENIC_VACUUM_P
- Service 22
DID 4B4E - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 bar
- Unit
- bar
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Vehicle status SCENIC_VEH
- Service 22
DID 4B1A - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Internal
Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018.
Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 kPa
- Unit
- kPa
Confirmed for 2018.
Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2018.
Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2018.
OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2006 to 2007.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2018.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2018.
Fuel
Current fuel level SCENIC_E_CURRENT_FLIConfirmed
- Service 22
DID 2201 - Module
743 → 763 - Every
30 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 L
- Unit
- L
0x0000 = 0 → = 0 L
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Fuel level displayed SCENIC_E_FLI_DISPLAYEDConfirmed
- Service 22
DID 2203 - Module
743 → 763 - Every
30 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 L
- Unit
- L
0x0000 = 0 → = 0 L
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Lights
Diagnostic light request SCENIC_OBD_LIGHT_REQ
- Service 22
DID 2028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Low beams on SCENIC_LOW_BEAMConfirmed
- Service 22
DID 4186 - Module
745 → 765 - Every
3 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Movement
Acceleration offset, lateral SCENIC_ACCEL_LAT_OFFSET
- Service 22
DID 4B37 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 g
- Unit
- g
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Acceleration offset, longitudinal SCENIC_ACCEL_LONG_OFFSET
- Service 22
DID 4B38 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Acceleration, lateral SCENIC_ACCEL_LAT
- Service 22
DID 4B0B - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 g
- Unit
- g
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Acceleration, longitudinal SCENIC_ACCEL_LONG
- Service 22
DID 4B07 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Accelerator pedal position SCENIC_ACCEL_POS
- Service 22
DID 202E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 81.91875 %
- Unit
- %
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Fan speed SCENIC_FAN_SPD
- Service 22
DID 912E - Module
DADB → DB - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.
Fan speed SCENIC_FAN_SPD_DADB
- Service 22
DID 91F0 - Module
DADB → DB - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2022, 2024 to 2026. Not supported for 2023.
FL wheel speed SCENIC_FL_VSS
- Service 22
DID 4B00 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km/h
- Unit
- km/h
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
FR wheel speed SCENIC_FR_VSS
- Service 22
DID 4B01 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km/h
- Unit
- km/h
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
RL wheel speed SCENIC_RL_VSS
- Service 22
DID 4B02 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km/h
- Unit
- km/h
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
RR wheel speed SCENIC_RR_VSS
- Service 22
DID 4B03 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km/h
- Unit
- km/h
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Speedometer index SCENIC_SPEEDO_IDX
- Service 22
DID 4B24 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mm
- Unit
- mm
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Steering wheel angle SCENIC_STEER_ANGLE
- Service 22
DID 0100 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °
- Unit
- °
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Steering wheel angle, offset SCENIC_STEER_ANGLE_OFFSET
- Service 22
DID 4B36 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Steering wheel speed SCENIC_STEER_SPD
- Service 22
DID 4B42 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Vehicle speed SCENIC_VSS
Pelican can show this parameter as the speed.
- Service 22
DID 2003 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 km/h
- Unit
- km/h
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Vehicle speed SCENIC_VSS_740
Pelican can show this parameter as the speed.
- Service 22
DID 4B04 - Module
740 → 760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km/h
- Unit
- km/h
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2018. Supported for 2006 to 2007.
Wheel speed sensor, signed SCENIC_WHEEL_SPD_SIGN
- Service 22
DID 4BBB - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Yaw angle SCENIC_YAW
- Service 22
DID 4B0C - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2018. Supported for 2006 to 2007.
Tires
Front left tire pressure SCENIC_TP_FLConfirmed
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 6300 - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 767.25 kPa
- Unit
- kPa
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Front left tire pressure alert SCENIC_TP_FL_ALERTConfirmed
- Service 22
DID 4109 - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
0x00 = 0 → NONE
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | ALERT | Alert |
2 | WARNING | Warning |
3 | ALERT | Alert |
4 | WARNING | Warning |
5 | ALERT | Alert |
6 | WARNING | Warning |
7 | ALERT | Alert |
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Front left tire temperature SCENIC_TT_FLConfirmed
Pelican can show this parameter as the front left tire temperature.
- Service 22
DID 6310 - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -30 to 97 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Front right tire pressure SCENIC_TP_FRConfirmed
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 6300 - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 767.25 kPa
- Unit
- kPa
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Front right tire pressure alert SCENIC_TP_FR_ALERTConfirmed
- Service 22
DID 410A - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
0x00 = 0 → NONE
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | ALERT | Alert |
2 | WARNING | Warning |
3 | ALERT | Alert |
4 | WARNING | Warning |
5 | ALERT | Alert |
6 | WARNING | Warning |
7 | ALERT | Alert |
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Front right tire pressure record, raw SCENIC_TP_FR_STATUSConfirmed
- Service 22
DID 6301 - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x03 = 3 → 3
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Front right tire temperature SCENIC_TT_FRConfirmed
Pelican can show this parameter as the front right tire temperature.
- Service 22
DID 6310 - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -30 to 97 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rear left tire pressure SCENIC_TP_RLConfirmed
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 6300 - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 767.25 kPa
- Unit
- kPa
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rear left tire pressure alert SCENIC_TP_RL_ALERTConfirmed
- Service 22
DID 410B - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
0x00 = 0 → NONE
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | ALERT | Alert |
2 | WARNING | Warning |
3 | ALERT | Alert |
4 | WARNING | Warning |
5 | ALERT | Alert |
6 | WARNING | Warning |
7 | ALERT | Alert |
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rear left tire pressure record, raw SCENIC_TP_RL_STATUSConfirmed
- Service 22
DID 6302 - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rear left tire temperature SCENIC_TT_RLConfirmed
Pelican can show this parameter as the rear left tire temperature.
- Service 22
DID 6310 - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -30 to 97 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rear right tire pressure SCENIC_TP_RRConfirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 6300 - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 767.25 kPa
- Unit
- kPa
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rear right tire pressure alert SCENIC_TP_RR_ALERTConfirmed
- Service 22
DID 410C - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
0x00 = 0 → NONE
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | ALERT | Alert |
2 | WARNING | Warning |
3 | ALERT | Alert |
4 | WARNING | Warning |
5 | ALERT | Alert |
6 | WARNING | Warning |
7 | ALERT | Alert |
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rear right tire pressure record, raw SCENIC_TP_RR_STATUSConfirmed
- Service 22
DID 6303 - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Rear right tire temperature SCENIC_TT_RRConfirmed
Pelican can show this parameter as the rear right tire temperature.
- Service 22
DID 6310 - Module
745 → 765 - Every
60 s - Testing for 1996 to 2022, 2024 to 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -30 to 97 °C
- Unit
- °C
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Transmission
Gearbox ratio SCENIC_GEARBOX_RATIO
- Service 22
DID 2C04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Gearbox ratio, target SCENIC_GEARBOX_RATIO_TGT
- Service 22
DID 2C03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022. Not supported for 2006, 2023, 2025.
Gearbox type SCENIC_GBOX_TYPE
- Service 22
DID 4B26 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Trips
Distance at first fault SCENIC_FAULT_DIST_FIRST
- Service 22
DID 4B09 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Distance units SCENIC_E_DIST_UNITSConfirmed
- Service 22
DID 0104 - Module
743 → 763 - Every
30 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b1 = 1 → 1
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.
Mileage since last fault SCENIC_FAULT_DIST_LAST
- Service 22
DID 4B0A - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Odometer SCENIC_E_ODO_KMConfirmed
- Service 22
DID 0207 - Module
743 - Every
30 s - Testing for 1996 to 2017, 2019 to 2022, 2024, 2026
Example reply from a 2025 Renault Scenic.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x000000 = 0 → 0 km
Confirmed for 2018, 2023, 2025. In testing for 1996 to 2005, 2008 to 2017, 2019 to 2022, 2024, 2026. Not supported for 2006 to 2007.
Odometer SCENIC_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID 4B06 - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 1996 to 2005, 2007 to 2022, 2024, 2026. Not supported for 2006, 2023, 2025.
Oil change range/current value in km SCENIC_E_OIL_CHANGE_RANGE_CURRENT_KMConfirmed
- Service 22
DID 0203 - Module
743 → 763 - Every
1 s - Testing for 1996 to 2022, 2024 to 2026
Example reply from a 2023 Renault Scenic.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 40720 mi
- Unit
- mi
0x0000 = 0 → = 0 mi
Confirmed for 2023. In testing for 1996 to 2022, 2024 to 2026.