AC refrigerant pressure sensor voltage RENAULT_AC_REFRIGERANT_P_V

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val×51023
Range
-160 to 160 V
Unit
V

In testing for 2015 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

AC refrigerant pressure sensor voltage RENAULT_AC_REFRIGERANT_P_V

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val×51023
Range
-160 to 160 V
Unit
V

In testing for 2015 to 2026.

Air flow sensor voltage RENAULT_AIR_FLOW_SENS_V

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The value is signed.

Formula
val×51023
Range
-160 to 160 V
Unit
V

In testing for 2015 to 2026.

Air inlet temperature sensor voltage RENAULT_AIR_INLET_T_SENS_V

  • Service 22DID FD84
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2015 to 2026.

Air temperature sensor voltage RENAULT_AIR_T_SENS_V

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val×51023
Range
-160 to 160 V
Unit
V

In testing for 2015 to 2026.

Air temperature sensor voltage RENAULT_AIR_T_SENS_V_7E0

  • Service 22DID FDB0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2015 to 2026.

Air temperature sensor voltage RENAULT_AIR_T_SENS_V_V2

  • Service 22DID FD84
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val6553.595
Range
0 to 9.99 V
Unit
V

In testing for 2015 to 2026.

Alternator charge information RENAULT_ALTERNATOR_CHG

  • Service 21PID 10
  • Module74D → 76D
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2015 to 2026.

Alternator set point voltage RENAULT_ALTERNATOR_SETPOINT_V

  • Service 22DID 28DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2015 to 2026.

Alternator set point voltage RENAULT_ALTERNATOR_SETPOINT_V_2

  • Service 22DID 1069
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 V
Unit
V

In testing for 2015 to 2026.

Alternator set point voltage RENAULT_ALTERNATOR_SETPOINT_V_7E0

  • Service 22DID 2A7F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2015 to 2026.

Alternator set point voltage RENAULT_ALTERNATOR_SETPOINT_V_7E0_2

  • Service 22DID 28DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2015 to 2026.

Alternator voltage set-point RENAULT_ALTERNATOR_V_SET

  • Service 22DID 28DC
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2015 to 2026.

Atmospheric pressure sensor voltage RENAULT_ATMOSPHERIC_P_SENS_V

  • Service 22DID 2012
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Atmospheric pressure sensor voltage RENAULT_ATMOSPHERIC_P_SENS_V_7E0

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val×51023
Range
-160 to 160 V
Unit
V

In testing for 2015 to 2026.

Average voltage of cells RENAULT_AVG_V_CELLS

  • Service 22DID 9006
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val69632
Range
-30840 to 30840 V
Unit
V

In testing for 2015 to 2026.

Battery capacity, DC RENAULT_DC_BAT_CAP

  • Service 22DID 91C8
  • ModuleDADB → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777 kWh
Unit
kWh

In testing for 2015 to 2026.

Battery cell voltage no. 1 RENAULT_BAT_CELL_V_NO_1

  • Service 22DID 9021
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 2 RENAULT_BAT_CELL_V_NO_2

  • Service 22DID 9022
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 3 RENAULT_BAT_CELL_V_NO_3

  • Service 22DID 9023
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 4 RENAULT_BAT_CELL_V_NO_4

  • Service 22DID 9024
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 5 RENAULT_BAT_CELL_V_NO_5

  • Service 22DID 9025
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 6 RENAULT_BAT_CELL_V_NO_6

  • Service 22DID 9026
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 7 RENAULT_BAT_CELL_V_NO_7

  • Service 22DID 9027
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 8 RENAULT_BAT_CELL_V_NO_8

  • Service 22DID 9028
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 9 RENAULT_BAT_CELL_V_NO_9

  • Service 22DID 9029
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 10 RENAULT_BAT_CELL_V_NO_10

  • Service 22DID 902A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 11 RENAULT_BAT_CELL_V_NO_11

  • Service 22DID 902B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 12 RENAULT_BAT_CELL_V_NO_12

  • Service 22DID 902C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 13 RENAULT_BAT_CELL_V_NO_13

  • Service 22DID 902D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 14 RENAULT_BAT_CELL_V_NO_14

  • Service 22DID 902E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 15 RENAULT_BAT_CELL_V_NO_15

  • Service 22DID 902F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 16 RENAULT_BAT_CELL_V_NO_16

  • Service 22DID 9030
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 17 RENAULT_BAT_CELL_V_NO_17

  • Service 22DID 9031
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 18 RENAULT_BAT_CELL_V_NO_18

  • Service 22DID 9032
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 19 RENAULT_BAT_CELL_V_NO_19

  • Service 22DID 9033
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 20 RENAULT_BAT_CELL_V_NO_20

  • Service 22DID 9034
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 21 RENAULT_BAT_CELL_V_NO_21

  • Service 22DID 9035
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 22 RENAULT_BAT_CELL_V_NO_22

  • Service 22DID 9036
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 23 RENAULT_BAT_CELL_V_NO_23

  • Service 22DID 9037
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 24 RENAULT_BAT_CELL_V_NO_24

  • Service 22DID 9038
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 25 RENAULT_BAT_CELL_V_NO_25

  • Service 22DID 9039
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 26 RENAULT_BAT_CELL_V_NO_26

  • Service 22DID 903A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 27 RENAULT_BAT_CELL_V_NO_27

  • Service 22DID 903B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 28 RENAULT_BAT_CELL_V_NO_28

  • Service 22DID 903C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 29 RENAULT_BAT_CELL_V_NO_29

  • Service 22DID 903D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 30 RENAULT_BAT_CELL_V_NO_30

  • Service 22DID 903E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 31 RENAULT_BAT_CELL_V_NO_31

  • Service 22DID 903F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 32 RENAULT_BAT_CELL_V_NO_32

  • Service 22DID 9041
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 33 RENAULT_BAT_CELL_V_NO_33

  • Service 22DID 9042
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 34 RENAULT_BAT_CELL_V_NO_34

  • Service 22DID 9043
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 35 RENAULT_BAT_CELL_V_NO_35

  • Service 22DID 9044
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 36 RENAULT_BAT_CELL_V_NO_36

  • Service 22DID 9045
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 37 RENAULT_BAT_CELL_V_NO_37

  • Service 22DID 9046
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 38 RENAULT_BAT_CELL_V_NO_38

  • Service 22DID 9047
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 39 RENAULT_BAT_CELL_V_NO_39

  • Service 22DID 9048
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 40 RENAULT_BAT_CELL_V_NO_40

  • Service 22DID 9049
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 41 RENAULT_BAT_CELL_V_NO_41

  • Service 22DID 904A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 42 RENAULT_BAT_CELL_V_NO_42

  • Service 22DID 904B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 43 RENAULT_BAT_CELL_V_NO_43

  • Service 22DID 904C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 44 RENAULT_BAT_CELL_V_NO_44

  • Service 22DID 904D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 45 RENAULT_BAT_CELL_V_NO_45

  • Service 22DID 904E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 46 RENAULT_BAT_CELL_V_NO_46

  • Service 22DID 904F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 47 RENAULT_BAT_CELL_V_NO_47

  • Service 22DID 9050
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 48 RENAULT_BAT_CELL_V_NO_48

  • Service 22DID 9051
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 49 RENAULT_BAT_CELL_V_NO_49

  • Service 22DID 9052
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 50 RENAULT_BAT_CELL_V_NO_50

  • Service 22DID 9053
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 51 RENAULT_BAT_CELL_V_NO_51

  • Service 22DID 9054
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 52 RENAULT_BAT_CELL_V_NO_52

  • Service 22DID 9055
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 53 RENAULT_BAT_CELL_V_NO_53

  • Service 22DID 9056
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 54 RENAULT_BAT_CELL_V_NO_54

  • Service 22DID 9057
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 55 RENAULT_BAT_CELL_V_NO_55

  • Service 22DID 9058
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 56 RENAULT_BAT_CELL_V_NO_56

  • Service 22DID 9059
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 57 RENAULT_BAT_CELL_V_NO_57

  • Service 22DID 905A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 58 RENAULT_BAT_CELL_V_NO_58

  • Service 22DID 905B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 59 RENAULT_BAT_CELL_V_NO_59

  • Service 22DID 905C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 60 RENAULT_BAT_CELL_V_NO_60

  • Service 22DID 905D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 61 RENAULT_BAT_CELL_V_NO_61

  • Service 22DID 905E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 62 RENAULT_BAT_CELL_V_NO_62

  • Service 22DID 905F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 63 RENAULT_BAT_CELL_V_NO_63

  • Service 22DID 9061
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 64 RENAULT_BAT_CELL_V_NO_64

  • Service 22DID 9062
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 65 RENAULT_BAT_CELL_V_NO_65

  • Service 22DID 9063
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 66 RENAULT_BAT_CELL_V_NO_66

  • Service 22DID 9064
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 67 RENAULT_BAT_CELL_V_NO_67

  • Service 22DID 9065
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 68 RENAULT_BAT_CELL_V_NO_68

  • Service 22DID 9066
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 69 RENAULT_BAT_CELL_V_NO_69

  • Service 22DID 9067
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 70 RENAULT_BAT_CELL_V_NO_70

  • Service 22DID 9068
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 71 RENAULT_BAT_CELL_V_NO_71

  • Service 22DID 9069
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 72 RENAULT_BAT_CELL_V_NO_72

  • Service 22DID 906A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 73 RENAULT_BAT_CELL_V_NO_73

  • Service 22DID 906B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 74 RENAULT_BAT_CELL_V_NO_74

  • Service 22DID 906C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 75 RENAULT_BAT_CELL_V_NO_75

  • Service 22DID 906D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 76 RENAULT_BAT_CELL_V_NO_76

  • Service 22DID 906E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 77 RENAULT_BAT_CELL_V_NO_77

  • Service 22DID 906F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 78 RENAULT_BAT_CELL_V_NO_78

  • Service 22DID 9070
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 79 RENAULT_BAT_CELL_V_NO_79

  • Service 22DID 9071
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 80 RENAULT_BAT_CELL_V_NO_80

  • Service 22DID 9072
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 81 RENAULT_BAT_CELL_V_NO_81

  • Service 22DID 9073
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 82 RENAULT_BAT_CELL_V_NO_82

  • Service 22DID 9074
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 83 RENAULT_BAT_CELL_V_NO_83

  • Service 22DID 9075
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 84 RENAULT_BAT_CELL_V_NO_84

  • Service 22DID 9076
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 85 RENAULT_BAT_CELL_V_NO_85

  • Service 22DID 9077
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 86 RENAULT_BAT_CELL_V_NO_86

  • Service 22DID 9078
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 87 RENAULT_BAT_CELL_V_NO_87

  • Service 22DID 9079
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 88 RENAULT_BAT_CELL_V_NO_88

  • Service 22DID 907A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 89 RENAULT_BAT_CELL_V_NO_89

  • Service 22DID 907B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 90 RENAULT_BAT_CELL_V_NO_90

  • Service 22DID 907C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 91 RENAULT_BAT_CELL_V_NO_91

  • Service 22DID 907D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 92 RENAULT_BAT_CELL_V_NO_92

  • Service 22DID 907E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 93 RENAULT_BAT_CELL_V_NO_93

  • Service 22DID 907F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 94 RENAULT_BAT_CELL_V_NO_94

  • Service 22DID 9081
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 95 RENAULT_BAT_CELL_V_NO_95

  • Service 22DID 9082
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery cell voltage no. 96 RENAULT_BAT_CELL_V_NO_96

  • Service 22DID 9083
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery charge RENAULT_BAT_CHG

  • Service 22DID 2958
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2015 to 2026.

Battery current, DC RENAULT_DC_BAT_CURRENT

  • Service 22DID 20FE
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×-14+500
Range
-15883 to 500 A
Unit
A

In testing for 2015 to 2026.

Battery fault finding RENAULT_BAT_FAULT_FINDING

  • Service 21PID 03
  • Module74D → 76D
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val2−20
Range
-20 to 107 °C
Unit
°C

In testing for 2015 to 2026.

Battery module 1 temperature RENAULT_MOD_T1

  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Battery module 2 temperature RENAULT_MOD_T2

  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Battery module 3 temperature RENAULT_MOD_T3

  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Battery module 4 temperature RENAULT_MOD_T4

  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Battery module 5 temperature RENAULT_MOD_T5

  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Battery module 6 temperature RENAULT_MOD_T6

  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Battery module 7 temperature RENAULT_MOD_T7

  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Battery module 8 temperature RENAULT_MOD_T8

  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Battery module 9 temperature RENAULT_MOD_T9

  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Battery module 10 temperature RENAULT_MOD_T10

  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Battery module 11 temperature RENAULT_MOD_T11

  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 263 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Battery module 12 temperature RENAULT_MOD_T12

  • Service 21PID 04
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Battery overvoltage RENAULT_BAT_OVERVOLTAGE

  • Service 22DID 2E37
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery overvoltage RENAULT_BAT_OVERVOLTAGE_7E1

  • Service 22DID 20B1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127 V
Unit
V

In testing for 2015 to 2026.

Battery state of charge RENAULT_BAT_ST_CHG

  • Service 22DID 2958
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2015 to 2026.

Battery state of charge, DC RENAULT_DC_BAT_ST_CHG

  • Service 22DID 9002
  • ModuleDADB → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2015 to 2026.

Battery state of health, DC RENAULT_DC_BAT_ST_HEALTH

  • Service 22DID 9003
  • ModuleDADB → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2015 to 2026.

Battery undervoltage RENAULT_BAT_UNDERVOLTAGE

  • Service 22DID 2E37
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery undervoltage RENAULT_BAT_UNDERVOLTAGE_7E1

  • Service 22DID 20B2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Battery voltage RENAULT_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2006
  • Module743 → 763
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2015 to 2026.

Battery voltage 12 v RENAULT_BAT_V_12_V_2

  • Service 22DID 1103
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×225
Range
0 to 20.4 V
Unit
V

In testing for 2015 to 2026.

BATTERY VOLTAGE 12 v RENAULT_BAT_V_12_V_7E0

  • Service 22DID 28EF
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2015 to 2026.

BATTERY VOLTAGE 12 v RENAULT_BAT_V_12_V_7E0_2

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The value is signed.

Formula
val×201023
Range
-640 to 640 V
Unit
V

In testing for 2015 to 2026.

BATTERY VOLTAGE 12 v RENAULT_BAT_V_12_V_7E1

  • Service 21PID A7
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2015 to 2026.

BATTERY VOLTAGE 12 v RENAULT_BAT_V_12_V_7E4

  • Service 22DID 2005
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2015 to 2026.

Battery voltage 12 v RENAULT_BAT_V_12_V_DADA

  • Service 22DID 2A7C
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2015 to 2026.

BATTERY VOLTAGE 12 v RENAULT_BAT_V_12_V_V2

  • Service 22DID 2005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2015 to 2026.

BATTERY VOLTAGE 12 v RENAULT_BAT_V_12_V_V3

  • Service 22DID 2006
  • Module743 → 763
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2015 to 2026.

Battery voltage after rest RENAULT_BAT_V_AFTER_REST

  • Service 21PID 9C
  • Module74D → 76D
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 V
Unit
V

In testing for 2015 to 2026.

Battery voltage, 12 V RENAULT_BAT_V_12_V

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4125+8
Range
0 to 16.16 V
Unit
V

In testing for 2015 to 2026.

Battery voltage, 12 V RENAULT_BAT_V_12_V_745

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×39500
Range
0 to 19.89 V
Unit
V

In testing for 2015 to 2026.

Battery voltage, 12 V RENAULT_BAT_V_12_V_74D

  • Service 21PID 10
  • Module74D → 76D
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 V
Unit
V

In testing for 2015 to 2026.

Battery voltage, 12V RENAULT_12V_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 3001
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2015 to 2026.

Boost pressure sensor voltage RENAULT_BOOST_P_SENS_V

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits. The value is signed.

Formula
val×51023
Range
-160 to 160 V
Unit
V

In testing for 2015 to 2026.

Boost pressure sensor voltage RENAULT_BOOST_P_SENS_V_7E0

  • Service 22DID 20C6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Boost pressure sensor voltage RENAULT_BOOST_P_SENS_V_V2

  • Service 22DID FD82
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2.98e-7
Range
0 to 0.0195 V
Unit
V

In testing for 2015 to 2026.

Bus bar voltage no. 1 RENAULT_BUSBAR_V_NO_1

  • Service 22DID 9221
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2015 to 2026.

Bus bar voltage no. 2 RENAULT_BUSBAR_V_NO_2

  • Service 22DID 9222
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2015 to 2026.

Bus bar voltage no. 3 RENAULT_BUSBAR_V_NO_3

  • Service 22DID 9223
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2015 to 2026.

Bus bar voltage no. 4 RENAULT_BUSBAR_V_NO_4

  • Service 22DID 9224
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2015 to 2026.

Bus bar voltage no. 5 RENAULT_BUSBAR_V_NO_5

  • Service 22DID 9225
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2015 to 2026.

Bus bar voltage no. 6 RENAULT_BUSBAR_V_NO_6

  • Service 22DID 9226
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2015 to 2026.

Bus bar voltage no. 7 RENAULT_BUSBAR_V_NO_7

  • Service 22DID 9227
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2015 to 2026.

Bus bar voltage no. 8 RENAULT_BUSBAR_V_NO_8

  • Service 22DID 9228
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2015 to 2026.

Cell with the highest voltage RENAULT_CELL_HIGHEST_V

  • Service 22DID 9008
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2015 to 2026.

Cell with the lowest voltage RENAULT_CELL_LOWEST_V

  • Service 22DID 900A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2015 to 2026.

Cells undervoltage RENAULT_CELLS_UNDERVOLTAGE

  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Charge circuit charger external interlock, DC RENAULT_DC_CHG_CIRCUIT

  • Service 22DID 314D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Charge plug present RENAULT_PLUG

Pelican can show this parameter as the plug state.

  • Service 22DID 2B85
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2015 to 2026.

Charge state RENAULT_CHG_STATE

  • Service 22DID 2B6D
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0STOPPEDStopped
1TIMER_WAITWaiting for timer
2DONEDone
3CHARGINGBattery
4INTERRUPTEDInterrupted
5POWER_WAITWaiting for power
6FLAP_OPENCharge flap open
8PREPARINGPreparing

In testing for 2015 to 2026.

Charge type RENAULT_CHG_TYPE

  • Service 22DID 2B7A
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNDEFINEDUndefined
1TYPE2Type 2
2TYPE2Type 2
3CHADEMOCHAdeMO
4CCS

In testing for 2015 to 2026.

Charging power available, AC RENAULT_AC_P_AVAIL

  • Service 22DID 300F
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638.375 kW
Unit
kW

In testing for 2015 to 2026.

Clutch cooling motor power supply voltage RENAULT_CLU_COOLING_MOTOR_V

  • Service 22DID 2043
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Clutch cooling motor power supply voltage RENAULT_CLU_COOLING_MOTOR_V_V2

  • Service 22DID 003F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 A
Unit
A

In testing for 2015 to 2026.

Complete charge cycles RENAULT_CYCLES

  • Service 22DID 9210
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Computer supply voltage RENAULT_COMPUTER_SUP_V

  • Service 21PID 01
  • Module742
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val256
Range
-128 to 127 V
Unit
V

In testing for 2015 to 2026.

Computer supply voltage RENAULT_COMPUTER_SUP_V_740

  • Service 21PID 06
  • Module740 → 760
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×225
Range
0 to 20.4 V
Unit
V

In testing for 2015 to 2026.

Computer supply voltage RENAULT_COMPUTER_SUP_V_752

  • Service 21PID 06
  • Module752 → 772
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×1011000
Range
0 to 25.75 V
Unit
V

In testing for 2015 to 2026.

Computer supply voltage RENAULT_COMPUTER_SUP_V_792

  • Service 22DID 2002
  • Module792
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 V
Unit
V

In testing for 2015 to 2026.

Computer supply voltage RENAULT_COMPUTER_SUP_V_7E1

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2015 to 2026.

Computer supply voltage RENAULT_COMPUTER_SUP_V_7E1_2

  • Service 22DID 1138
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×451
Range
0 to 20 V
Unit
V

In testing for 2015 to 2026.

Computer supply voltage RENAULT_ECU_V

  • Service 22DID 012F
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2015 to 2026.

Coolant temperature sensor voltage RENAULT_ECT_SENS_V

  • Service 22DID FD8B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5000
Range
-6.55 to 6.55 V
Unit
V

In testing for 2015 to 2026.

Coolant temperature sensor voltage RENAULT_ECT_SENS_V_7E0

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×51023
Range
-160 to 160 V
Unit
V

In testing for 2015 to 2026.

Damper valve sensor voltage RENAULT_DAMPER_VLV_SENS_V

  • Service 22DID 2417
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Dcdc set point voltage RENAULT_DCDC_SETPOINT_V

  • Service 22DID 2A87
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2015 to 2026.

Downshift paddle voltage RENAULT_DOWNSHIFT_PADDLE_V

  • Service 22DID 2322
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2015 to 2026.

Downstream oxygen sensor heating voltage RENAULT_DN_OXYGEN_SENS_HEATING_V

  • Service 22DID 1159
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2015 to 2026.

Downstream oxygen sensor voltage RENAULT_DN_OXYGEN_SENS_V

  • Service 21PID A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×24425
Range
0 to 2488 mV
Unit
mV

In testing for 2015 to 2026.

Downstream oxygen sensor voltage RENAULT_DN_OXYGEN_SENS_V_2

  • Service 22DID 111A
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100
Range
0 to 2.55 V
Unit
V

In testing for 2015 to 2026.

Downstream oxygen sensor voltage RENAULT_DN_OXYGEN_SENS_V_7E0

  • Service 22DID FDAA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2015 to 2026.

Energy charged, total RENAULT_E_CHG

  • Service 22DID 9243
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967.295 kWh
Unit
kWh

In testing for 2015 to 2026.

Energy discharged, total RENAULT_E_DISCHG

  • Service 22DID 9245
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967.295 kWh
Unit
kWh

In testing for 2015 to 2026.

Energy regenerated, total RENAULT_E_REGEN

  • Service 22DID 9247
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967.295 kWh
Unit
kWh

In testing for 2015 to 2026.

Exhaust air valve position sensor voltage RENAULT_EXH_AIR_VLV_POS_SENS_V

  • Service 22DID FDA8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2015 to 2026.

Exhaust gas recirculation POTENTIOMETER VOLTAGE RENAULT_EGR_POTENTIOMETER_V

  • Service 22DID 2424
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Exhaust gas recirculation SENSOR SUPPLY VOLTAGE RENAULT_EGR_SENS_SUP_V

  • Service 22DID 24D5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Exhaust gas recirculation VALVE POSITION SENSOR VOLTAGE RENAULT_EGR_VLV_POS_SENS_V

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The value is signed.

Formula
val×51023
Range
-160 to 160 V
Unit
V

In testing for 2015 to 2026.

Front wiper protection, EMM RENAULT_EMM_FRONT_WIPER

  • Service 21PID 10
  • Module74D → 76D
  • Every5 s
  • Testing

Bits 78 to 79 of the reply, 2 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2015 to 2026.

Fuel temperature sensor voltage RENAULT_FUEL_T_SENS_V

  • Service 22DID FD89
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5000
Range
-6.55 to 6.55 V
Unit
V

In testing for 2015 to 2026.

Fuel temperature sensor voltage RENAULT_FUEL_T_SENS_V_7E0

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val×51023
Range
-160 to 160 V
Unit
V

In testing for 2015 to 2026.

Gearbox oil pressure sensor voltage RENAULT_GEARBOX_OIL_P_SENS_V

  • Service 21PID A2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×985
Range
0 to 4998 mV
Unit
mV

In testing for 2015 to 2026.

Gearbox oil temperature sensor voltage RENAULT_GEARBOX_OIL_T_SENS_V

  • Service 21PID A2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×985
Range
0 to 4998 mV
Unit
mV

In testing for 2015 to 2026.

Gearbox oil temperature sensor voltage RENAULT_GEARBOX_OIL_T_SENS_V_7E1

  • Service 22DID 2389
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2015 to 2026.

Gross pedal sensor track 2 voltage RENAULT_GROSS_PEDAL_SENS_2_V

  • Service 22DID FDAF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2015 to 2026.

High voltage battery available energy RENAULT_HV_E_AVAIL

  • Service 22DID 91C8
  • ModuleDADB → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777.215 kWh
Unit
kWh

In testing for 2015 to 2026.

High voltage battery average temperature RENAULT_HV_T

  • Service 22DID 9012
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

High voltage battery current RENAULT_HV_A

Pelican can show this parameter as the traction battery current.

  • Service 22DID 925D
  • ModuleDADB → DB
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×-132+1020
Range
-1027.97 to 1020 A
Unit
A

In testing for 2015 to 2026.

High voltage battery current RENAULT_HV_A_3042

  • Service 22DID 3042
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−16383.75
Range
-16383.75 to 16383.75 A
Unit
A

In testing for 2015 to 2026.

High voltage battery current, power electronics RENAULT_HV_A_PEB

  • Service 22DID 3204
  • Module7E4 → 7EC
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−8192
Range
-8192 to 8191.75 A
Unit
A

In testing for 2015 to 2026.

High voltage battery current, raw RENAULT_HV_A_3042_RAW

  • Service 22DID 3042
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

High voltage battery current, vehicle controller RENAULT_HV_A_EVC

  • Service 22DID 21CC
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−500
Range
-500 to 15883.75 A
Unit
A

In testing for 2015 to 2026.

High voltage battery voltage RENAULT_HV_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 9005
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2015 to 2026.

High voltage battery voltage, power electronics RENAULT_HV_V_PEB

  • Service 22DID 3203
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 V
Unit
V

In testing for 2015 to 2026.

High voltage battery voltage, vehicle controller RENAULT_HV_V_EVC

  • Service 22DID 20FE
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2015 to 2026.

Highest cell voltage level RENAULT_HIGHEST_CELL_V_LEVEL

  • Service 22DID 9007
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Inlet flap sensor supply voltage RENAULT_INLET_FLAP_SENS_SUP_V

  • Service 22DID 24D6
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Inlet pressure sensor voltage RENAULT_INLET_P_SENS_V

  • Service 22DID FD81
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000152588
Range
0 to 9.99 V
Unit
V

In testing for 2015 to 2026.

Input shaft speed sensor 1 voltage RENAULT_INPUT_SHFT_SPD_SENS_1_V

  • Service 22DID 2072
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Input shaft speed sensor 2 voltage RENAULT_INPUT_SHFT_SPD_SENS_2_V

  • Service 22DID 2082
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Intake air temperature sensor voltage RENAULT_IAT_SENS_V

  • Service 22DID FD84
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×532768
Range
0 to 9.99 V
Unit
V

In testing for 2015 to 2026.

Interlocks traction battery charge RENAULT_INTERLOCKS_TRACTION

  • Service 22DID 314D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Lever position sensor power supply voltage RENAULT_LEVER_POS_SENS_POWER_SUP_V

  • Service 22DID 231B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2015 to 2026.

Lever position sensor power supply voltage RENAULT_LEVER_POS_SENS_POWER_V

  • Service 22DID 2094
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Lever position sensor power supply voltage RENAULT_LEVER_POS_SENS_POWER_V_V2

  • Service 22DID 0000
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Low pressure EGR valve supply voltage RENAULT_LOW_P_EGR_VLV_SUP_V

  • Service 22DID 257B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Lowest cell voltage level RENAULT_LOWEST_CELL_V_LEVEL

  • Service 22DID 9009
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Mains current, AC RENAULT_AC_A

  • Service 22DID 300D
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2015 to 2026.

Mains phases, AC RENAULT_AC_PHASES

  • Service 22DID 300B
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0ONEOne phase
1TWOTwo phase
2THREEThree phase
3NONENot detected

In testing for 2015 to 2026.

Mains voltage, AC RENAULT_AC_V

  • Service 22DID 2B8A
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 V
Unit
V

In testing for 2015 to 2026.

Mastervac pressure sensor voltage RENAULT_MASTERVAC_P_SENS_V

  • Service 22DID 20AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 6 to 7 of the reply, 2 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2015 to 2026.

Maximum charge power RENAULT_CHG_P_MAX

  • Service 22DID 9018
  • ModuleDADB → DB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kW
Unit
kW

In testing for 2015 to 2026.

Maximum power authorized in charge mode RENAULT_MAX_POWER_AUTHORIZED

  • Service 22DID 221F
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 kW
Unit
kW

In testing for 2015 to 2026.

Open circuit voltage RENAULT_OPEN_CIRCUIT_V

  • Service 22DID 9005
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2015 to 2026.

Oxygen sensor voltage RENAULT_OXYGEN_SENS_V

  • Service 22DID FDAB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.27 V
Unit
V

In testing for 2015 to 2026.

Pack temperature 1 RENAULT_PACK_T1

  • Service 22DID 9131
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

Pack temperature 2 RENAULT_PACK_T2

  • Service 22DID 9132
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

Pack temperature 3 RENAULT_PACK_T3

  • Service 22DID 9133
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

Pack temperature 4 RENAULT_PACK_T4

  • Service 22DID 9134
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

Pack temperature 5 RENAULT_PACK_T5

  • Service 22DID 9135
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

Pack temperature 6 RENAULT_PACK_T6

  • Service 22DID 9136
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

Pack temperature 7 RENAULT_PACK_T7

  • Service 22DID 9137
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

Pack temperature 8 RENAULT_PACK_T8

  • Service 22DID 9138
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

Pack temperature 9 RENAULT_PACK_T9

  • Service 22DID 9139
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

Pack temperature 10 RENAULT_PACK_T10

  • Service 22DID 913A
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

Pack temperature 11 RENAULT_PACK_T11

  • Service 22DID 913B
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

Pack temperature 12 RENAULT_PACK_T12

  • Service 22DID 913C
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2015 to 2026.

PART.FILTER UPSTREAM temperature SENSOR VOLTAGE RENAULT_PART_FLT_UP_T_SENS_V

  • Service 22DID FD88
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 mV
Unit
mV

In testing for 2015 to 2026.

Particle filter pressure sensor voltage RENAULT_PARTICLE_FLT_P_SENS_V

  • Service 22DID 2446
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Pedal potentiometer track 1 voltage RENAULT_PEDAL_POTENTIOMETER_1_V

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×201023
Range
0 to 4.98 V
Unit
V

In testing for 2015 to 2026.

Pedal potentiometer track 1 voltage RENAULT_PEDAL_POTENTIOMETER_1_V_2

  • Service 22DID 120D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2015 to 2026.

Pedal potentiometer track 1 voltage RENAULT_PEDAL_POTENTIOMETER_1_V_V2

  • Service 22DID 200B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Pedal potentiometer track 1 voltage RENAULT_PEDAL_POTENTIOMETER_1_V_V3

  • Service 22DID 200B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Pedal potentiometer track 1 voltage RENAULT_PEDAL_POTENTIOMETER_TRACK_1_V

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits. The value is signed.

Formula
val×51023
Range
-160 to 160 V
Unit
V

In testing for 2015 to 2026.

Pedal potentiometer track 2 voltage RENAULT_PEDAL_POTENTIOMETER_2_V

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×201023
Range
0 to 4.98 V
Unit
V

In testing for 2015 to 2026.

Pedal potentiometer track 2 voltage RENAULT_PEDAL_POTENTIOMETER_2_V_2

  • Service 22DID 120E
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2015 to 2026.

Pedal potentiometer track 2 voltage RENAULT_PEDAL_POTENTIOMETER_2_V_V2

  • Service 22DID 200C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Pedal potentiometer track 2 voltage RENAULT_PEDAL_POTENTIOMETER_2_V_V3

  • Service 22DID 200C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Pedal potentiometer track 2 voltage RENAULT_PEDAL_POTENTIOMETER_TRACK_2_V

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits. The value is signed.

Formula
val×51023
Range
-160 to 160 V
Unit
V

In testing for 2015 to 2026.

Phases 1-2 voltage RENAULT_PHASES_1_2_V

  • Service 22DID 503F
  • Module792
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 V
Unit
V

In testing for 2015 to 2026.

Phases 2-3 voltage RENAULT_PHASES_2_3_V

  • Service 22DID 5041
  • Module792
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 V
Unit
V

In testing for 2015 to 2026.

Pilot controle voltage RENAULT_PILOT_CONTROLE_V

  • Service 22DID 3089
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val4
Range
-32 to 31.75 V
Unit
V

In testing for 2015 to 2026.

Pilot controle voltage RENAULT_PILOT_CONTROLE_V_V2

  • Service 22DID 5027
  • Module792
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4−15
Range
-15 to 48.75 V
Unit
V

In testing for 2015 to 2026.

Power consumed by charger RENAULT_POWER_CONSUMED

  • Service 22DID 300E
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 kW
Unit
kW

In testing for 2015 to 2026.

Power consumed by charger RENAULT_POWER_CONSUMED_V2

  • Service 22DID 504A
  • Module792
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−20000
Range
-20000 to 45535 W
Unit
W

In testing for 2015 to 2026.

Rail pressure sensor voltage RENAULT_RAIL_P_SENS_V

  • Service 22DID FD8A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2015 to 2026.

Rail pressure sensor voltage RENAULT_RAIL_P_SENS_V_7E0

  • Service 21PID A6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The value is signed.

Formula
val×4.887585531000
Range
-160 to 160 V
Unit
V

In testing for 2015 to 2026.

Refrigerant fluid sensor voltage RENAULT_REFRIGERANT_FLUID_V

  • Service 22DID 200D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2015 to 2026.

Rv/lv button voltage RENAULT_RV_LV_BUTTON_V

  • Service 22DID 2039
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Rv/lv button voltage RENAULT_RV_LV_BUTTON_V_2

  • Service 22DID 2039
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Rv/lv button voltage RENAULT_RV_LV_BUTTON_V_V2

  • Service 22DID 2039
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Sensor supply no. 3 voltage RENAULT_SENS_SUP_NO_3_V

  • Service 22DID 2023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Sensor supply number 1 voltage RENAULT_SENS_SUP_N_1_V

  • Service 22DID FDA5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Sensor supply voltage RENAULT_SENS_SUP_V

  • Service 22DID FDD6
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Sensor supply voltage RENAULT_SENS_SUP_V_2

  • Service 22DID 2023
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Sensor supply voltage RENAULT_SENS_SUP_V_7E0

  • Service 22DID FDA6
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Sensors no. 1 feed voltage RENAULT_SENSORS_NO_1_FEED_V

  • Service 22DID 2021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Sensors no. 2 feed voltage RENAULT_SENSORS_NO_2_FEED_V

  • Service 22DID 2022
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

State of charge RENAULT_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 9002
  • ModuleDADB → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

State of charge RENAULT_SOC_9002

  • Service 22DID 9002
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2015 to 2026.

State of charge battery RENAULT_ST_CHG_BAT

  • Service 22DID 20BE
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 %
Unit
%

In testing for 2015 to 2026.

State of charge battery RENAULT_ST_CHG_BAT_DADA

  • Service 22DID 21CD
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2015 to 2026.

State of charge, battery controller RENAULT_SOC_9001

  • Service 22DID 9001
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2015 to 2026.

State of charge, vehicle controller RENAULT_SOC_EVC

  • Service 22DID 2002
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 %
Unit
%

In testing for 2015 to 2026.

State of health RENAULT_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID 9003
  • ModuleDADB → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2015 to 2026.

Supply voltage exhaust air flap sensor RENAULT_SUP_V_EXH_AIR_FLAP

  • Service 22DID 257D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Supply voltage, ECU RENAULT_ECU_SUPPLY_V

  • Service 22DID 2005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2015 to 2026.

Swirl flap voltage RENAULT_SWIRL_FLAP_V

  • Service 22DID 2595
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Temperature. cooling system traction battery RENAULT_T_COOLING_SYSTEM

  • Service 21PID 21
  • Module744 → 764
  • Every5 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2015 to 2026.

Throttle valve control voltage RENAULT_THROTTLE_VLV_CTRL_V

  • Service 22DID 246F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val100−83886.08
Range
-83886 to 83886 mV
Unit
mV

In testing for 2015 to 2026.

Traction battery access flap interlock RENAULT_TRACTION_BAT_ACCESS

  • Service 22DID 314D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Traction battery charging duration RENAULT_TRACTION_BAT_CHG_DUR

  • Service 22DID 3086
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2015 to 2026.

Traction battery compartment temperature RENAULT_TRACTION_BAT_T

  • Service 22DID 9012
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Traction battery input water temperature RENAULT_TRACTION_BAT_INPUT_T

  • Service 22DID 91CD
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Traction battery interlock RENAULT_TRACTION_BAT_2

  • Service 22DID 305A
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Traction battery interlock RENAULT_TRACTION_BAT_INTERLOCK

  • Service 22DID 91F7
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Traction battery interlock RENAULT_TRACTION_BAT_INTERLOCK_2

  • Service 22DID 220D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Traction battery interlock RENAULT_TRACTION_BAT_INTERLOCK_DADA

  • Service 22DID 314D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Traction battery interlock->peb/inverter RENAULT_TRACTION_BAT_INTERLOCK_PEB

  • Service 22DID 314D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Traction battery max temperature RENAULT_TRACTION_BAT_MAX_T

  • Service 22DID 9014
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Traction battery max temperature RENAULT_TRACTION_BAT_MAX_T_2

  • Service 22DID 21D7
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Traction battery min. temperature RENAULT_TRACTION_BAT_MIN_T

  • Service 22DID 9013
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Traction battery min. temperature RENAULT_TRACTION_BAT_MIN_T_2

  • Service 22DID 21D8
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Traction battery overcurrent RENAULT_TRACTION_BAT_OVERCURRENT

  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Traction battery overheating RENAULT_TRACTION_BAT

  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Traction battery relay RENAULT_TRACTION_BAT_RELAY

  • Service 22DID 21C9
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Traction battery service plug interlock RENAULT_TRACTION_BAT_SERVICE

  • Service 22DID 91F6
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Traction battery SOC RENAULT_TRACTION_BAT_SOC

  • Service 22DID 9001
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−3
Range
-3 to 652 %
Unit
%

In testing for 2015 to 2026.

Traction battery total mileage RENAULT_TRACTION_BAT_TOT

  • Service 22DID 91CF
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val32+67108864
Range
0 to 134217727 km
Unit
km

In testing for 2015 to 2026.

Traction battery voltage by peb/inverter RENAULT_TRACTION_BAT_V_PEB

  • Service 22DID 20B6
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2015 to 2026.

Traction battery voltage measured by dcdc RENAULT_TRACTION_BAT_V_MEAS

  • Service 22DID 20FD
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2015 to 2026.

Traction battery, current RENAULT_TRACTION_BAT_CURRENT

  • Service 22DID 9257
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−1020
Range
-1020 to 1027 A
Unit
A

In testing for 2015 to 2026.

Traction battery, current RENAULT_TRACTION_BAT_CURRENT_DADB

  • Service 22DID 9284
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-2147483 to 2147483 A
Unit
A

In testing for 2015 to 2026.

Traction battery, current RENAULT_TRACTION_BAT_CURRENT_V2

  • Service 22DID 9284
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×-11000
Range
-2147483 to 2147483 A
Unit
A

In testing for 2015 to 2026.

Turbine upstream pressure sensor voltage RENAULT_TURBINE_UP_P_SENS_V

  • Service 22DID FD86
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2015 to 2026.

Turbine upstream temperature. sensor voltage RENAULT_TURBINE_UP_T_SENS_V

  • Service 22DID 129A
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val800
Range
0 to 81.91 V
Unit
V

In testing for 2015 to 2026.

TURBINE UPSTREAM temperature. SENSOR VOLTAGE RENAULT_TURBINE_UP_T_SENS_V_V2

  • Service 22DID 243A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0001526
Range
0 to 10 V
Unit
V

In testing for 2015 to 2026.

Upshift paddle voltage RENAULT_UPSHIFT_PADDLE_V

  • Service 22DID 231F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2015 to 2026.

Upstream oxygen sensor voltage RENAULT_UP_OXYGEN_SENS_V

  • Service 21PID A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×24425
Range
0 to 2488 mV
Unit
mV

In testing for 2015 to 2026.

Upstream oxygen sensor voltage RENAULT_UP_OXYGEN_SENS_V_2

  • Service 22DID 1225
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2015 to 2026.

Upstream oxygen sensor voltage RENAULT_UP_OXYGEN_SENS_V_7E0

  • Service 22DID FDAC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51024
Range
0 to 319 V
Unit
V

In testing for 2015 to 2026.

Voltage measured throttle track 1 RENAULT_V_MEAS_THROTTLE_1

  • Service 22DID 2418
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Voltage measured throttle track 1 RENAULT_V_MEAS_THROTTLE_1_V2

  • Service 22DID 120F
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2015 to 2026.

Voltage measured throttle track 2 RENAULT_V_MEAS_THROTTLE_2

  • Service 22DID 2419
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Voltage measured throttle track 2 RENAULT_V_MEAS_THROTTLE_2_V2

  • Service 22DID 1210
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2015 to 2026.

Cells

Cell 1 voltage RENAULT_CELL_V1

  • Service 22DID 9021
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 1 voltage RENAULT_CELL1_V1

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 2 voltage RENAULT_CELL_V2

  • Service 22DID 9022
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 2 voltage RENAULT_CELL1_V2

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 3 voltage RENAULT_CELL_V3

  • Service 22DID 9023
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 3 voltage RENAULT_CELL1_V3

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 4 voltage RENAULT_CELL_V4

  • Service 22DID 9024
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 4 voltage RENAULT_CELL1_V4

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 5 voltage RENAULT_CELL_V5

  • Service 22DID 9025
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 5 voltage RENAULT_CELL1_V5

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 6 voltage RENAULT_CELL_V6

  • Service 22DID 9026
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 6 voltage RENAULT_CELL1_V6

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 7 voltage RENAULT_CELL_V7

  • Service 22DID 9027
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 7 voltage RENAULT_CELL1_V7

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 8 voltage RENAULT_CELL_V8

  • Service 22DID 9028
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 8 voltage RENAULT_CELL1_V8

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 9 voltage RENAULT_CELL_V9

  • Service 22DID 9029
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 9 voltage RENAULT_CELL1_V9

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 10 voltage RENAULT_CELL_V10

  • Service 22DID 902A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 10 voltage RENAULT_CELL1_V10

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 11 voltage RENAULT_CELL_V11

  • Service 22DID 902B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 11 voltage RENAULT_CELL1_V11

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 12 voltage RENAULT_CELL_V12

  • Service 22DID 902C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 12 voltage RENAULT_CELL1_V12

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 13 voltage RENAULT_CELL_V13

  • Service 22DID 902D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 13 voltage RENAULT_CELL1_V13

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 14 voltage RENAULT_CELL_V14

  • Service 22DID 902E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 14 voltage RENAULT_CELL1_V14

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 15 voltage RENAULT_CELL_V15

  • Service 22DID 902F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 15 voltage RENAULT_CELL1_V15

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 16 voltage RENAULT_CELL_V16

  • Service 22DID 9030
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 16 voltage RENAULT_CELL1_V16

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 17 voltage RENAULT_CELL_V17

  • Service 22DID 9031
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 17 voltage RENAULT_CELL1_V17

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 18 voltage RENAULT_CELL_V18

  • Service 22DID 9032
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 18 voltage RENAULT_CELL1_V18

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 19 voltage RENAULT_CELL_V19

  • Service 22DID 9033
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 19 voltage RENAULT_CELL1_V19

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 20 voltage RENAULT_CELL_V20

  • Service 22DID 9034
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 20 voltage RENAULT_CELL1_V20

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 21 voltage RENAULT_CELL_V21

  • Service 22DID 9035
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 21 voltage RENAULT_CELL1_V21

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 22 voltage RENAULT_CELL_V22

  • Service 22DID 9036
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 22 voltage RENAULT_CELL1_V22

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 23 voltage RENAULT_CELL_V23

  • Service 22DID 9037
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 23 voltage RENAULT_CELL1_V23

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 24 voltage RENAULT_CELL_V24

  • Service 22DID 9038
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 24 voltage RENAULT_CELL1_V24

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 25 voltage RENAULT_CELL_V25

  • Service 22DID 9039
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 25 voltage RENAULT_CELL1_V25

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 26 voltage RENAULT_CELL_V26

  • Service 22DID 903A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 26 voltage RENAULT_CELL1_V26

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 27 voltage RENAULT_CELL_V27

  • Service 22DID 903B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 27 voltage RENAULT_CELL1_V27

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 28 voltage RENAULT_CELL_V28

  • Service 22DID 903C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 28 voltage RENAULT_CELL1_V28

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 29 voltage RENAULT_CELL_V29

  • Service 22DID 903D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 29 voltage RENAULT_CELL1_V29

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 30 voltage RENAULT_CELL_V30

  • Service 22DID 903E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 30 voltage RENAULT_CELL1_V30

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 31 voltage RENAULT_CELL_V31

  • Service 22DID 903F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 31 voltage RENAULT_CELL1_V31

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 32 voltage RENAULT_CELL_V32

  • Service 22DID 9041
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 32 voltage RENAULT_CELL1_V32

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 33 voltage RENAULT_CELL_V33

  • Service 22DID 9042
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 33 voltage RENAULT_CELL1_V33

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 34 voltage RENAULT_CELL_V34

  • Service 22DID 9043
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 34 voltage RENAULT_CELL1_V34

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 35 voltage RENAULT_CELL_V35

  • Service 22DID 9044
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 35 voltage RENAULT_CELL1_V35

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 36 voltage RENAULT_CELL_V36

  • Service 22DID 9045
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 36 voltage RENAULT_CELL1_V36

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 37 voltage RENAULT_CELL_V37

  • Service 22DID 9046
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 37 voltage RENAULT_CELL1_V37

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 38 voltage RENAULT_CELL_V38

  • Service 22DID 9047
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 38 voltage RENAULT_CELL1_V38

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 39 voltage RENAULT_CELL_V39

  • Service 22DID 9048
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 39 voltage RENAULT_CELL1_V39

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 40 voltage RENAULT_CELL_V40

  • Service 22DID 9049
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 40 voltage RENAULT_CELL1_V40

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 41 voltage RENAULT_CELL_V41

  • Service 22DID 904A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 41 voltage RENAULT_CELL1_V41

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 42 voltage RENAULT_CELL_V42

  • Service 22DID 904B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 42 voltage RENAULT_CELL1_V42

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 43 voltage RENAULT_CELL_V43

  • Service 22DID 904C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 43 voltage RENAULT_CELL1_V43

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 44 voltage RENAULT_CELL_V44

  • Service 22DID 904D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 44 voltage RENAULT_CELL1_V44

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 45 voltage RENAULT_CELL_V45

  • Service 22DID 904E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 45 voltage RENAULT_CELL1_V45

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 46 voltage RENAULT_CELL_V46

  • Service 22DID 904F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 46 voltage RENAULT_CELL1_V46

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 47 voltage RENAULT_CELL_V47

  • Service 22DID 9050
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 47 voltage RENAULT_CELL1_V47

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 48 voltage RENAULT_CELL_V48

  • Service 22DID 9051
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 48 voltage RENAULT_CELL1_V48

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 49 voltage RENAULT_CELL_V49

  • Service 22DID 9052
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 49 voltage RENAULT_CELL1_V49

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 50 voltage RENAULT_CELL_V50

  • Service 22DID 9053
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 50 voltage RENAULT_CELL1_V50

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 51 voltage RENAULT_CELL_V51

  • Service 22DID 9054
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 51 voltage RENAULT_CELL1_V51

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 52 voltage RENAULT_CELL_V52

  • Service 22DID 9055
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 52 voltage RENAULT_CELL1_V52

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 53 voltage RENAULT_CELL_V53

  • Service 22DID 9056
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 53 voltage RENAULT_CELL1_V53

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 54 voltage RENAULT_CELL_V54

  • Service 22DID 9057
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 54 voltage RENAULT_CELL1_V54

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 55 voltage RENAULT_CELL_V55

  • Service 22DID 9058
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 55 voltage RENAULT_CELL1_V55

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 56 voltage RENAULT_CELL_V56

  • Service 22DID 9059
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 56 voltage RENAULT_CELL1_V56

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 57 voltage RENAULT_CELL_V57

  • Service 22DID 905A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 57 voltage RENAULT_CELL1_V57

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 58 voltage RENAULT_CELL_V58

  • Service 22DID 905B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 58 voltage RENAULT_CELL1_V58

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 59 voltage RENAULT_CELL_V59

  • Service 22DID 905C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 59 voltage RENAULT_CELL1_V59

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 60 voltage RENAULT_CELL_V60

  • Service 22DID 905D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 60 voltage RENAULT_CELL1_V60

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 61 voltage RENAULT_CELL_V61

  • Service 22DID 905E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 61 voltage RENAULT_CELL1_V61

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 62 voltage RENAULT_CELL_V62

  • Service 22DID 905F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 62 voltage RENAULT_CELL1_V62

  • Service 21PID 41
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 63 voltage RENAULT_CELL_V63

  • Service 22DID 9061
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 63 voltage RENAULT_CELL1_V63

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 64 voltage RENAULT_CELL_V64

  • Service 22DID 9062
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 64 voltage RENAULT_CELL1_V64

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 65 voltage RENAULT_CELL_V65

  • Service 22DID 9063
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 65 voltage RENAULT_CELL1_V65

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 66 voltage RENAULT_CELL_V66

  • Service 22DID 9064
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 66 voltage RENAULT_CELL1_V66

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 67 voltage RENAULT_CELL_V67

  • Service 22DID 9065
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 67 voltage RENAULT_CELL1_V67

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 68 voltage RENAULT_CELL_V68

  • Service 22DID 9066
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 68 voltage RENAULT_CELL1_V68

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 69 voltage RENAULT_CELL_V69

  • Service 22DID 9067
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 69 voltage RENAULT_CELL1_V69

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 70 voltage RENAULT_CELL_V70

  • Service 22DID 9068
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 70 voltage RENAULT_CELL1_V70

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 71 voltage RENAULT_CELL_V71

  • Service 22DID 9069
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 71 voltage RENAULT_CELL1_V71

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 72 voltage RENAULT_CELL_V72

  • Service 22DID 906A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 72 voltage RENAULT_CELL1_V72

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 73 voltage RENAULT_CELL_V73

  • Service 22DID 906B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 73 voltage RENAULT_CELL1_V73

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 74 voltage RENAULT_CELL_V74

  • Service 22DID 906C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 74 voltage RENAULT_CELL1_V74

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 75 voltage RENAULT_CELL_V75

  • Service 22DID 906D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 75 voltage RENAULT_CELL1_V75

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 76 voltage RENAULT_CELL_V76

  • Service 22DID 906E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 76 voltage RENAULT_CELL1_V76

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 77 voltage RENAULT_CELL_V77

  • Service 22DID 906F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 77 voltage RENAULT_CELL1_V77

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 78 voltage RENAULT_CELL_V78

  • Service 22DID 9070
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 78 voltage RENAULT_CELL1_V78

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 79 voltage RENAULT_CELL_V79

  • Service 22DID 9071
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 79 voltage RENAULT_CELL1_V79

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 80 voltage RENAULT_CELL_V80

  • Service 22DID 9072
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 80 voltage RENAULT_CELL1_V80

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 81 voltage RENAULT_CELL_V81

  • Service 22DID 9073
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 81 voltage RENAULT_CELL1_V81

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 82 voltage RENAULT_CELL_V82

  • Service 22DID 9074
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 82 voltage RENAULT_CELL1_V82

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 83 voltage RENAULT_CELL_V83

  • Service 22DID 9075
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 83 voltage RENAULT_CELL1_V83

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 84 voltage RENAULT_CELL_V84

  • Service 22DID 9076
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 84 voltage RENAULT_CELL1_V84

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 85 voltage RENAULT_CELL_V85

  • Service 22DID 9077
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 85 voltage RENAULT_CELL1_V85

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 86 voltage RENAULT_CELL_V86

  • Service 22DID 9078
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 86 voltage RENAULT_CELL1_V86

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 87 voltage RENAULT_CELL_V87

  • Service 22DID 9079
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 87 voltage RENAULT_CELL1_V87

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 88 voltage RENAULT_CELL_V88

  • Service 22DID 907A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 88 voltage RENAULT_CELL1_V88

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 89 voltage RENAULT_CELL_V89

  • Service 22DID 907B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 89 voltage RENAULT_CELL1_V89

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 90 voltage RENAULT_CELL_V90

  • Service 22DID 907C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 90 voltage RENAULT_CELL1_V90

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 91 voltage RENAULT_CELL_V91

  • Service 22DID 907D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 91 voltage RENAULT_CELL1_V91

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 92 voltage RENAULT_CELL_V92

  • Service 22DID 907E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 92 voltage RENAULT_CELL1_V92

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 93 voltage RENAULT_CELL_V93

  • Service 22DID 907F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 93 voltage RENAULT_CELL1_V93

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 94 voltage RENAULT_CELL_V94

  • Service 22DID 9081
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 94 voltage RENAULT_CELL1_V94

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 95 voltage RENAULT_CELL_V95

  • Service 22DID 9082
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 95 voltage RENAULT_CELL1_V95

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Cell 96 voltage RENAULT_CELL_V96

  • Service 22DID 9083
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2015 to 2026.

Cell 96 voltage RENAULT_CELL1_V96

  • Service 21PID 42
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Climate

A/C compressor RENAULT_AC_COMP

  • Service 22DID 201E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

A/C compressor discharge temperature RENAULT_COMP_DIS_T

  • Service 22DID 440C
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−30
Range
-30 to 32737.5 °C
Unit
°C

In testing for 2015 to 2026.

A/C compressor mode RENAULT_COMP_MODE

  • Service 22DID 4402
  • Module744 → 764
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
1ACA/C
2DEICEDe-ice
4HEAT_PUMPHeat pump
6DEMISTDemisting
7IDLEIdle

In testing for 2015 to 2026.

A/C compressor power RENAULT_COMP_PWR

  • Service 22DID 4436
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 W
Unit
W

In testing for 2015 to 2026.

A/C compressor pressure RENAULT_COMP_P

  • Service 22DID 4369
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2015 to 2026.

A/C compressor speed RENAULT_COMP_RPM

  • Service 22DID 43D8
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2015 to 2026.

A/C compressor speed request RENAULT_COMP_RPM_REQ

  • Service 22DID 4404
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2015 to 2026.

A/C compressor suction temperature RENAULT_COMP_SUC_T

  • Service 22DID 440D
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−30
Range
-30 to 32737.5 °C
Unit
°C

In testing for 2015 to 2026.

Ambient air temperature RENAULT_AAT

  • Service 22DID 2218
  • ModuleDADA → DA
  • Every20 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280.5 °C
Unit
°C

In testing for 2015 to 2026.

Cabin temperature RENAULT_CABIN_T

  • Service 22DID 4009
  • Module744 → 764
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−40
Range
-3316.8 to 3236.7 °C
Unit
°C

In testing for 2015 to 2026.

Electric heater request RENAULT_PTC_REQ

  • Service 22DID 4341
  • Module744 → 764
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2015 to 2026.

Evaporator temperature RENAULT_EVAP_T

  • Service 22DID 400A
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2015 to 2026.

Evaporator temperature set point RENAULT_EVAP_T_SET

  • Service 22DID 4368
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2015 to 2026.

Heating condenser temperature RENAULT_COND_T

  • Service 22DID 4429
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2015 to 2026.

Heating condenser temperature set point RENAULT_COND_T_SET

  • Service 22DID 43A5
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512−40
Range
-40 to 87.998 °C
Unit
°C

In testing for 2015 to 2026.

Heating temperature RENAULT_HEAT_T

  • Service 22DID 43A4
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2015 to 2026.

Heating temperature, raw RENAULT_HEAT_T_RAW

  • Service 22DID 43A4
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Refrigerant pressure RENAULT_REFRIG_P

  • Service 22DID 222A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2015 to 2026.

Refrigerant pressure sensor voltage RENAULT_REFRIG_P_SNS_V

  • Service 22DID 200D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2015 to 2026.

Control

Anti-lock brake SIGNAL RENAULT_ABS_SIG

  • Service 22DID 234F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Anti-lock brakes and stability control RENAULT_ABS_ESP

  • Service 22DID 2088
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Brake contact connection RENAULT_BRAKE_CONTACT

  • Service 22DID 2221
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Brake contact duration 1 RENAULT_BRAKE_CONTACT_1_DUR

  • Service 22DID 206A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2015 to 2026.

Brake contact duration 2 RENAULT_BRAKE_CONTACT_2_DUR

  • Service 22DID 206B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2015 to 2026.

Brake contact, wired RENAULT_WIRED_BRAKE_CONTACT

  • Service 22DID 2026
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Brake dive limiter RENAULT_BRAKE_DIVE

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Brake dive limiter function RENAULT_BRAKE_DIVE_LIMITER

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Brake dive limiter, warning RENAULT_BRAKE_DIVE_WARN

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Brake fluid level warning RENAULT_BRAKE_NIVOCODE_WARN

  • Service 21PID 10
  • Module743 → 763
  • Every5 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Brake information absent RENAULT_BRAKE_INFORMATION

  • Service 22DID 204F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Brake information absent RENAULT_BRAKE_INFORMATION_V2

  • Service 22DID 204F
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Brake information unavailable RENAULT_BRAKE_INFORMATION_UNAVAILABLE

  • Service 22DID 204F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Brake information unavailable RENAULT_BRAKE_INFORMATION_UNAVAILABLE_V2

  • Service 22DID 204F
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Brake lights on request RENAULT_BRAKE_LIGHTS_ON_REQ

  • Service 22DID 4B10
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Brake lights request RENAULT_BRAKE_LIGHTS

  • Service 22DID 4B15
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Brake pedal RENAULT_BRAKE_PEDAL

  • Service 22DID 4B11
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Brake pedal RENAULT_BRAKE_PEDAL_740

  • Service 21PID 06
  • Module740 → 760
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Brake pedal RENAULT_BRAKE_PEDAL_7E0

  • Service 22DID 2025
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Brake pedal RENAULT_BRAKE_PEDAL_7E1

  • Service 21PID A6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Brake pedal RENAULT_BRAKE_PEDAL_7E1_2

  • Service 22DID 20D3
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Brake pedal RENAULT_BRAKE_PEDAL_7E1_V2

  • Service 22DID 200F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Brake pedal RENAULT_BRAKE_PEDAL_V2

  • Service 22DID 2025
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 6 to 7 of the reply, 2 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2015 to 2026.

Brake pedal position RENAULT_BRAKE_PEDAL_POS

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 186 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Brake pedal position recognition RENAULT_BRAKE_PEDAL_POS_V2

  • Service 22DID 0062
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Brake pedal pressed RENAULT_BRAKE_PEDAL_PRESSED

  • Service 22DID 2350
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 bar
Unit
bar

In testing for 2015 to 2026.

Brake pressure, master cylinder RENAULT_BRAKE_P_MC

  • Service 22DID 4B0E
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 bar
Unit
bar

In testing for 2015 to 2026.

Brake switch RENAULT_BRAKE_SWITCH_V2

  • Service 22DID 206E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Brake switch information RENAULT_BRAKE_SWITCH

  • Service 22DID 1305
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Brake switch, number 1 RENAULT_BRAKE_SWITCH_NUMBER_1

  • Service 21PID D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Brake switch, number 2 RENAULT_BRAKE_SWITCH_NUMBER_2

  • Service 21PID D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 71 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Braking detected multiplex signal RENAULT_BRAKE_MUX_SIG

  • Service 22DID 200F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Handbrake position recognition RENAULT_HANDBRAKE_POS

  • Service 22DID 2D11
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Low brake solenoid, current RENAULT_LOW_BRAKE_SOLENOID

  • Service 22DID 1215
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 A
Unit
A

In testing for 2015 to 2026.

Main brake switch RENAULT_MAIN_BRAKE_SWITCH

  • Service 22DID 20A3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Parking brake RENAULT_PARK_BRAKE

  • Service 22DID 4B27
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Parking brake RENAULT_PARKING_BRAKE

  • Service 21PID 10
  • Module743 → 763
  • Every5 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Parking brake RENAULT_PARKING_BRAKE_V2

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Parking brake switch RENAULT_PARKING_BRAKE_SWITCH

  • Service 22DID 20F6
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Steering wheel angle RENAULT_STEER_WHL_ANG_742

  • Service 22DID 0104
  • Module742
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.7
Range
-3276 to 3276 °
Unit
°

In testing for 2015 to 2026.

Steering wheel speed RENAULT_STEER_WHL_SPD_CALC

  • Service 22DID 0101
  • Module742
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.7
Range
-3276 to 3276
Unit
Raw value

In testing for 2015 to 2026.

Target low brake pressure RENAULT_TARGETLOW_BRAKE_P

  • Service 22DID 112A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 bar
Unit
bar

In testing for 2015 to 2026.

Doors

Central door locking button RENAULT_CENTRAL_DOOR_LOCKING

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Driver's door RENAULT_DRIVER_S_DOOR

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Front left door open RENAULT_FL_DOOR

  • Service 22DID 6026
  • Module745 → 765
  • Every3 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Front right door open RENAULT_FR_DOOR

  • Service 22DID 6027
  • Module745 → 765
  • Every3 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Left hand rear door RENAULT_LEFT_HAND_REAR_DOOR

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Passenger's door RENAULT_PASSENGER_S_DOOR

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Rear left door open RENAULT_RL_DOOR

  • Service 22DID 61B2
  • Module745 → 765
  • Every3 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Rear right door RENAULT_RR_DOOR

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Rear right door open RENAULT_RR_DOOR_V2

  • Service 22DID 61B3
  • Module745 → 765
  • Every3 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Tailgate open RENAULT_TAILGATE

  • Service 22DID 609B
  • Module745 → 765
  • Every3 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Vehicle locked RENAULT_LOCKED

  • Service 22DID 8004
  • Module745 → 765
  • Every3 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Drivetrain

2WD mode switch RENAULT_2WD_MODE_SW

  • Service 22DID 3005
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

4WD mode monitor RENAULT_4WD_MODE_MON

  • Service 22DID 3024
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

4WD mode switch RENAULT_4WD_MODE_SW

  • Service 22DID 3005
  • Module748
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Auto mode switch RENAULT_AUTO_MODE_SW

  • Service 22DID 3005
  • Module748
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Driving type RENAULT_DRIVE_TYPE

  • Service 22DID 4B3C
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engine torque control RENAULT_ENGINE_TORQUE_CTRL

  • Service 22DID 3010
  • Module748
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Inverter high voltage RENAULT_INV_HV_V

  • Service 22DID 2004
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.9687 V
Unit
V

In testing for 2015 to 2026.

Inverter high voltage current RENAULT_INV_HV_A

  • Service 22DID 7049
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−500
Range
-500 to 1547.9687 A
Unit
A

In testing for 2015 to 2026.

Inverter high voltage current, raw RENAULT_INV_HV_A_RAW

  • Service 22DID 7049
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647
Unit
Number

In testing for 2015 to 2026.

Inverter state RENAULT_INV_STATE

  • Service 22DID 21CF
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
1OFFOff
2ONOn
3DISCHARGINGDischarging
4ALTERNATORAlternator mode
5SLEEP_READYReady to sleep

In testing for 2015 to 2026.

Inverter temperature RENAULT_INV_T

  • Service 22DID 700C
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val512−40
Range
-40 to 32727.998 °C
Unit
°C

In testing for 2015 to 2026.

Inverter temperature, power electronics RENAULT_INV_T_PEB

  • Service 22DID 33F6
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Inverter temperature, raw RENAULT_INV_T_RAW

  • Service 22DID 700C
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647
Unit
Number

In testing for 2015 to 2026.

Motor speed RENAULT_MOTOR_RPM

  • Service 22DID 3064
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2015 to 2026.

Operating mode RENAULT_OP_MODE

  • Service 22DID 3026
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Operating mode, selected RENAULT_OP_MODE_SEL

  • Service 22DID 3023
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Rotor current sensor 1 RENAULT_ROTOR_A1

  • Service 22DID 7003
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 A
Unit
A

In testing for 2015 to 2026.

Rotor current sensor 2 RENAULT_ROTOR_A2

  • Service 22DID 7004
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 A
Unit
A

In testing for 2015 to 2026.

Rotor reference resistance RENAULT_ROTOR_R

  • Service 22DID 7050
  • ModuleDADF → DF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 Ω
Unit
Ω

In testing for 2015 to 2026.

Rotor temperature, estimated RENAULT_ROTOR_T

  • Service 22DID 7088
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128−40
Range
-40 to 471.9921 °C
Unit
°C

In testing for 2015 to 2026.

Rotor temperature, raw RENAULT_ROTOR_T_RAW

  • Service 22DID 7038
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128−40
Range
-40 to 471.9921 °C
Unit
°C

In testing for 2015 to 2026.

Stator current, phase u RENAULT_STATOR_A_U

  • Service 22DID 7007
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−500
Range
-500 to 1547.9687 A
Unit
A

In testing for 2015 to 2026.

Stator current, phase U, raw RENAULT_STATOR_A_U_RAW

  • Service 22DID 7007
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647
Unit
Number

In testing for 2015 to 2026.

Stator current, phase v RENAULT_STATOR_A_V

  • Service 22DID 7008
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−500
Range
-500 to 1547.9687 A
Unit
A

In testing for 2015 to 2026.

Stator current, phase V, raw RENAULT_STATOR_A_V_RAW

  • Service 22DID 7008
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647
Unit
Number

In testing for 2015 to 2026.

Stator current, phase w RENAULT_STATOR_A_W

  • Service 22DID 7009
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−500
Range
-500 to 1547.9687 A
Unit
A

In testing for 2015 to 2026.

Stator current, phase W, raw RENAULT_STATOR_A_W_RAW

  • Service 22DID 7009
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647
Unit
Number

In testing for 2015 to 2026.

Stator temperature 1 RENAULT_STATOR_T1

  • Service 22DID 700F
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val512−40
Range
-40 to 32727.998 °C
Unit
°C

In testing for 2015 to 2026.

Stator temperature 1, raw RENAULT_STATOR_T1_RAW

  • Service 22DID 700F
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647
Unit
Number

In testing for 2015 to 2026.

Stator temperature 2 RENAULT_STATOR_T2

  • Service 22DID 7010
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val512−40
Range
-40 to 32727.998 °C
Unit
°C

In testing for 2015 to 2026.

Traction control RENAULT_TRACTION_CTRL_V2

  • Service 22DID 3010
  • Module748
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Trajectory control RENAULT_TRAJECTORY_CTRL

  • Service 22DID 3010
  • Module748
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

ECU

Fault counter RENAULT_FAULT_CNT

  • Service 22DID 4B05
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fault cycles since disappeared RENAULT_FAULT_CYCLES

  • Service 22DID 4B08
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Supplier number RENAULT_SUPPLIER_NUM

  • Service 22DID 4B3D
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Electrical

12V battery current RENAULT_12V_A

  • Service 22DID 6079
  • Module74D → 76D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2015 to 2026.

12V battery voltage RENAULT_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2005
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2015 to 2026.

Alternator load RENAULT_ALT_LOAD

  • Service 22DID 2099
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Alternator power RENAULT_ALT_PWR

  • Service 22DID 2057
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 W
Unit
W

In testing for 2015 to 2026.

Hazard lights LED RENAULT_HAZARD_LED

  • Service 22DID 4B14
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Sensor feed voltage 1 RENAULT_SNS_FEED_V1

  • Service 22DID 2021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Sensor feed voltage 2 RENAULT_SNS_FEED_V2

  • Service 22DID 2022
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Engine

#dcdc temperature RENAULT_DCDC_T

  • Service 22DID 21D0
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

#deconnection failure counter RENAULT_DECONNECTION_FAILURE

  • Service 22DID 226E
  • ModuleDADA → DA
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

+ 12 v after ignition RENAULT_12_V_AFTER_IGN

  • Service 21PID 10
  • Module743 → 763
  • Every5 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

+ 12 v after ignition relay control RENAULT_12_V_AFTER_IGN_RELAY

  • Service 21PID 10
  • Module74D → 76D
  • Every5 s
  • Testing

Bit 91 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

+ after ignition RENAULT_AFTER_IGN

  • Service 22DID FDE5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

+ after ignition present RENAULT_AFTER_IGN_PRESENT

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

1st inlet valve closure programmed RENAULT_1ST_INLET_VLV_CLOSURE

  • Service 22DID 2478
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

1st inlet valve opening programmed RENAULT_1ST_INLET_VLV

  • Service 22DID 2477
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

ABS, warning RENAULT_ABS_WARN

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Absolute time since first ignition RENAULT_ABS_TIME_SINCE_FIRST

  • Service 22DID 23B4
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2015 to 2026.

Absolute time since first ignition RENAULT_ABS_TIME_SINCE_FIRST_IGN

  • Service 22DID 9261
  • ModuleDADB → DAF1DB
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2015 to 2026.

Absolute time since first ignition RENAULT_ABS_TIME_SINCE_FIRST_V2

  • Service 22DID 00B4
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647
Unit
Number

In testing for 2015 to 2026.

Accelerator pedal detection blocked RENAULT_ACCEL_DETECT_BLOCKED

  • Service 22DID 2036
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Accelerator pedal potentiometer voltage, track 1 RENAULT_ACCEL_POT_V1

  • Service 22DID 200B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Accelerator pedal potentiometer voltage, track 2 RENAULT_ACCEL_POT_V2

  • Service 22DID 200C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Active emergency braking RENAULT_ACTIVE_EMERGENCY

  • Service 22DID 2A7A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Active emergency braking RENAULT_ACTIVE_EMERGENCY_2

  • Service 22DID 2A7A
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Adaptative cruise control brake request RENAULT_ADAPTATIVE_CRUISE

  • Service 22DID 2177
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Adaptive cruise control braking request RENAULT_ACC_BRAKING_REQ

  • Service 22DID 2177
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Adaptive cruise control frame reception status RENAULT_ACC_FRAME_RECEPTION

  • Service 22DID 2175
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 5 to 7 of the reply, 3 bits.

Formula
val
Range
0 to 7
Unit
Number

In testing for 2015 to 2026.

Adaptive cruise control frame reception status RENAULT_ACC_FRAME_RECEPTION_2

  • Service 22DID 2175
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Adaptive cruise control status reception by sl button RENAULT_ACC_STAT_RECEPTION

  • Service 22DID 2C51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Adaptive cruise control status reception by sl button RENAULT_ACC_STAT_RECEPTION_2

  • Service 22DID 2C51
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Adaptive cruise control torque request RENAULT_ADAPTIVE_CRUISE_CTRL

  • Service 22DID 2174
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Advance after anti-pinking correction RENAULT_ADVANCE_AFTER_ANTI

  • Service 21PID A9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×38−23.625
Range
-23.62 to 72 °
Unit
°

In testing for 2015 to 2026.

Advance reference RENAULT_ADVANCE_REFERENCE

  • Service 22DID 112D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °
Unit
°

In testing for 2015 to 2026.

Air bag fault warning light RENAULT_AIR_BAG_FAULT_WARN

  • Service 21PID 03
  • Module752 → 772
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Air conditioning authorization RENAULT_AC_AUTHORIZATION

  • Service 22DID 2092
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Air conditioning command RENAULT_AC_COMMAND

  • Service 22DID 2229
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Air conditioning compressor RENAULT_AC_COMP_74D

  • Service 21PID 10
  • Module74D → 76D
  • Every5 s
  • Testing

Bit 72 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Air conditioning key RENAULT_AC_KEY

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 81 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Air conditioning mode RENAULT_AC_MODE

  • Service 21PID 44
  • Module744 → 764
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Air conditioning signal RENAULT_AC_SIG

  • Service 22DID 1302
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Air conditioning type RENAULT_AC_TYPE

  • Service 21PID C0
  • Module745 → 765
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Air flap set point RENAULT_AIR_FLAP_SET_POINT

  • Service 22DID 25D4
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.392156863
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Air flow RENAULT_AIR_FLOW

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2015 to 2026.

Air flow RENAULT_AIR_FLOW_V2

  • Service 22DID 2422
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276
Unit
Raw value

In testing for 2015 to 2026.

Air flow difference RENAULT_AIR_FLOW_DIFF

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2015 to 2026.

Air flow reference RENAULT_AIR_FLOW_REFERENCE

  • Service 22DID 2413
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2015 to 2026.

Air flow reference for EGR RENAULT_AIR_FLOW_REFERENCE_EGR

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2015 to 2026.

Air heater resistor management, AC RENAULT_AC_AIR_HEATER

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Air inlet flap absolute position RENAULT_AIR_INLET_FLAP_ABS

  • Service 22DID 1198
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Air inlet flap absolute position RENAULT_AIR_INLET_FLAP_ABS_V2

  • Service 22DID 24CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Air inlet flap relative position RENAULT_AIR_INLET_FLAP_REL

  • Service 22DID 2404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Air inlet temperature sensor voltage RENAULT_AIR_INLET_T_SNS_V

  • Service 22DID FD83
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.9997 V
Unit
V

In testing for 2015 to 2026.

Air pump RENAULT_AIR_PMP

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Air regulation cut-off conditions RENAULT_AIR_REGULATION_CUT_OFF

  • Service 22DID FD9E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−273.15
Range
-273 to 3822 °C
Unit
°C

In testing for 2015 to 2026.

Air temperature RENAULT_AIR_T

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 2015 to 2026.

Air temperature RENAULT_AIR_T_7E0

  • Service 22DID 20DE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Air temperature RENAULT_AIR_T_V2

  • Service 22DID 003B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 °C
Unit
°C

In testing for 2015 to 2026.

Air-conditioning compressor interlock RENAULT_AC_COMP_INTERLOCK

  • Service 22DID 314D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Alternator drive ratio RENAULT_ALTERNATOR_DRIVE_RAT

  • Service 22DID 117B
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2015 to 2026.

Alternator load RENAULT_ALTERNATOR_LOAD

  • Service 22DID 2099
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Alternator load RENAULT_ALTERNATOR_LOAD_2

  • Service 22DID 28E1
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10031
Range
0 to 822 %
Unit
%

In testing for 2015 to 2026.

Alternator load RENAULT_ALTERNATOR_LOAD_7E0

  • Service 22DID 28E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Alternator load RENAULT_ALTERNATOR_LOAD_7E0_2

  • Service 21PID A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The value is signed.

Formula
val×252048
Range
-400 to 399 %
Unit
%

In testing for 2015 to 2026.

Alternator load RENAULT_ALTERNATOR_LOAD_DA15

  • Service 22DID 28E1
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.392156863
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Alternator load RENAULT_ALTERNATOR_LOAD_V2

  • Service 22DID 28DF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 A
Unit
A

In testing for 2015 to 2026.

Alternator type RENAULT_ALTERNATOR_TYPE

  • Service 21PID 96
  • Module74D → 76D
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Ambient temperature RENAULT_AAT_DA15

  • Service 22DID 20DE
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Amount of air pumped into cylinder RENAULT_AMOUNT_AIR_PUMPED

  • Service 22DID 2422
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276
Unit
Raw value

In testing for 2015 to 2026.

Angular position of the exhaust VVTC system RENAULT_ANGULAR_POS_EXH_VVTC

  • Service 22DID 224E
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310
Unit
Number

In testing for 2015 to 2026.

Angular position target of the exhaust VVTC system RENAULT_ANGULAR_POS_TGT_EXH

  • Service 22DID 224F
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310
Unit
Number

In testing for 2015 to 2026.

Anti - rollover control function RENAULT_ANTI_ROLLOVER_CTRL

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Anti-knock correction RENAULT_ANTI_KNOCK_CORR

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×38
Range
0 to 95.62 °
Unit
°

In testing for 2015 to 2026.

Anti-lock brakes RENAULT_ABS

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Anti-rollover control RENAULT_ANTI_ROLL

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Anti-rollover control, warning RENAULT_ANTI_ROLL_WARN

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Anticipated engine torque RENAULT_ANTICIPATED_ENG_TQ

  • Service 22DID 2343
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Atmospheric pressure RENAULT_ATMOSPHERIC_P

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×-3710+1047
Range
0 to 1047
Unit
Raw value

In testing for 2015 to 2026.

Atmospheric pressure RENAULT_ATMOSPHERIC_P_2

  • Service 22DID 1129
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×28564+105.566406
Range
0 to 1241
Unit
Raw value

In testing for 2015 to 2026.

Atmospheric pressure RENAULT_ATMOSPHERIC_P_7E0

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2015 to 2026.

Atmospheric pressure RENAULT_ATMOSPHERIC_P_7E0_2

  • Service 22DID F433
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 2015 to 2026.

Atmospheric pressure RENAULT_ATMOSPHERIC_P_7E0_V2

  • Service 22DID 2009
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Atmospheric pressure RENAULT_ATMOSPHERIC_P_DA15

  • Service 22DID 2009
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Auto emergency braking system request RENAULT_AUTO_EMERGENCY

  • Service 22DID 2170
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Auto emergency braking system request RENAULT_AUTO_EMERGENCY_V2

  • Service 22DID 2170
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Automatic adaptations RENAULT_AUTO_ADAPTIVES

  • Service 22DID 1336
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Automatic lighting button RENAULT_AUTOMATIC_LIGHTING

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 75 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Automatic park function RENAULT_AUTOMATIC_PARK

  • Service 22DID 2AFF
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Auxiliary electric motor interlock RENAULT_AUXILIARY_ELEC_MOTOR

  • Service 22DID 314D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Average knock signal RENAULT_AVG_KNOCK_SIG

  • Service 21PID A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Average knock signal RENAULT_AVG_KNOCK_SIG_7E0

  • Service 22DID FDC1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2015 to 2026.

Average knock signal RENAULT_AVG_KNOCK_SIG_7E0_2

  • Service 22DID FDC2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2015 to 2026.

Average temperature of sensors RENAULT_AVG_T_SENSORS

  • Service 22DID FE1A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 ms
Unit
ms

In testing for 2015 to 2026.

Bcb air temperature RENAULT_BCB_AIR_T

  • Service 22DID 20DE
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Bcb air temperature RENAULT_BCB_AIR_T_V2

  • Service 22DID 5054
  • Module792
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Belt starter generator temperature RENAULT_BSG_T

  • Service 22DID 312F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Boost pressure RENAULT_BOOST_P

  • Service 22DID 2401
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2015 to 2026.

Boost pressure RENAULT_BOOST_P_7E0

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val×37640+103
Range
0 to 3891
Unit
Raw value

In testing for 2015 to 2026.

Boost pressure RENAULT_BOOST_P_7E0_2

  • Service 22DID 20C4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Boost pressure RENAULT_BOOST_P_7E0_V2

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2015 to 2026.

Boost pressure reference value RENAULT_BOOST_P_REFERENCE

  • Service 22DID 2402
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Boost pressure reference value RENAULT_BOOST_P_REFERENCE_7E0

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2015 to 2026.

Boost pressure wastegate control RENAULT_BOOST_P_WASTEGATE_CTRL

  • Service 22DID FE1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Boost pressure wastegate control RENAULT_BOOST_P_WASTEGATE_CTRL_V2

  • Service 22DID 24C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107−49.999237
Range
-49.99 to 50 %
Unit
%

In testing for 2015 to 2026.

Boost pressure wastegate duty cycle RENAULT_BOOST_P_WASTEGATE

  • Service 22DID 24E5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 85 %
Unit
%

In testing for 2015 to 2026.

Brake booster pressure RENAULT_MASTERVAC_P_2

  • Service 22DID 2893
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 bar
Unit
bar

In testing for 2015 to 2026.

Brake booster pressure RENAULT_MASTERVAC_P_7E0

  • Service 22DID 2891
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Brake booster pressure RENAULT_MASTERVAC_P_V2

  • Service 22DID 2894
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2015 to 2026.

Brake booster pressure switch signal RENAULT_MASTERVAC_P_SWITCH

  • Service 22DID 2890
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Braking information defect mode RENAULT_BRAKING_INFORMATION

  • Service 22DID 2221
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Brief press doors and boot close button RENAULT_BRIEF_PRESS_DOORS

  • Service 21PID 13
  • Module745 → 765
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Bus bar no. 1 RENAULT_BUSBAR_NO_1

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Bus bar no. 2 RENAULT_BUSBAR_NO_2

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Bus bar no. 3 RENAULT_BUSBAR_NO_3

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Bus bar no. 4 RENAULT_BUSBAR_NO_4

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Bus bar no. 5 RENAULT_BUSBAR_NO_5

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Bus bar no. 6 RENAULT_BUSBAR_NO_6

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Bus bar no. 7 RENAULT_BUSBAR_NO_7

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Bus bar no. 8 RENAULT_BUSBAR_NO_8

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Bus bar no. 9 RENAULT_BUSBAR_NO_9

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Bus bar no. 10 RENAULT_BUSBAR_NO_10

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Bus bar no. 11 RENAULT_BUSBAR_NO_11

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Bus bar no. 12 RENAULT_BUSBAR_NO_12

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Bypass solenoid valve control valve RENAULT_BYPASS_SOLENOID_VLV

  • Service 22DID 25D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Calculated engine torque RENAULT_CALC_ENG_TQ

  • Service 21PID A2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2015 to 2026.

Calculated load value RENAULT_CALC_LOAD

  • Service 22DID FD28
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

In testing for 2015 to 2026.

Calculated load value RENAULT_CALC_LOAD_2

  • Service 22DID 1117
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Camshaft / TDC synchronisation RENAULT_CAM_TDC

  • Service 22DID 2014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Camshaft top dead center synchronization RENAULT_CAM_TDC_SYNC

  • Service 22DID 2014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Can-adas communication RENAULT_CAN_ADAS

  • Service 22DID 3095
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Can-adas communication RENAULT_CAN_ADAS_2

  • Service 22DID 3095
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Canister bleed OBD RENAULT_CANISTER_BLEED_OBD

  • Service 22DID 28D9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Canister bleed solenoid valve duty cycle RENAULT_CANISTER_BLEED

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Canister bleed solenoid valve duty cycle RENAULT_CANISTER_BLEED_SOL_RCO

  • Service 22DID 2822
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Canister bleed solenoid valve RCO RENAULT_CANISTER_BLEED_V2

  • Service 22DID 2822
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val655
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Carbon material rate RENAULT_CARBON_MATERIAL_RATE

  • Service 22DID 211F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×1.2e-9+2.5
Range
0 to 4.99 %
Unit
%

In testing for 2015 to 2026.

Carbon material rate RENAULT_CARBON_MATERIAL_RATE_V2

  • Service 22DID 2281
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×1.2e-9+2.5
Range
0 to 4.99 %
Unit
%

In testing for 2015 to 2026.

Cc inhibited by evc RENAULT_CC_INHIBITED_EVC

  • Service 22DID 204F
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Cc inhibited by injection RENAULT_CC_INHIBITED_INJ

  • Service 22DID 204F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Cc operating reliably RENAULT_CC_OP_RELIABLY

  • Service 22DID 204D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cc operating reliably RENAULT_CC_OP_RELIABLY_7E0

  • Service 22DID 217E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cc/sl connection after cc button pressed RENAULT_CC_SL_CONNECTION

  • Service 22DID 203B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cc/sl connection after sl button pressed RENAULT_CC_SL_CONNECTION_AFTER_SL

  • Service 22DID 203E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cc/sl connection authorization RENAULT_CC_SL_CONNECTION_AUTHORISATION

  • Service 22DID 222F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Cc/sl deactivation by driver action RENAULT_CC_SL_DEACTIVATION

  • Service 22DID 2078
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

CELL, number 1 RENAULT_CELL_NUMBER_1

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 255 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 2 RENAULT_CELL_NUMBER_2

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 254 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 3 RENAULT_CELL_NUMBER_3

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 253 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 4 RENAULT_CELL_NUMBER_4

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 252 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 5 RENAULT_CELL_NUMBER_5

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 251 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 6 RENAULT_CELL_NUMBER_6

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 250 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 7 RENAULT_CELL_NUMBER_7

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 249 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 8 RENAULT_CELL_NUMBER_8

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 248 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 9 RENAULT_CELL_NUMBER_9

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 247 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 10 RENAULT_CELL_NUMBER_10

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 246 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 11 RENAULT_CELL_NUMBER_11

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 245 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 12 RENAULT_CELL_NUMBER_12

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 244 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 13 RENAULT_CELL_NUMBER_13

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 243 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 14 RENAULT_CELL_NUMBER_14

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 242 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 15 RENAULT_CELL_NUMBER_15

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 241 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 16 RENAULT_CELL_NUMBER_16

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 240 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 17 RENAULT_CELL_NUMBER_17

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 239 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 18 RENAULT_CELL_NUMBER_18

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 238 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 19 RENAULT_CELL_NUMBER_19

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 237 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 20 RENAULT_CELL_NUMBER_20

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 236 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 21 RENAULT_CELL_NUMBER_21

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 235 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 22 RENAULT_CELL_NUMBER_22

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 234 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 23 RENAULT_CELL_NUMBER_23

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 233 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 24 RENAULT_CELL_NUMBER_24

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 232 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 25 RENAULT_CELL_NUMBER_25

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 231 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 26 RENAULT_CELL_NUMBER_26

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 230 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 27 RENAULT_CELL_NUMBER_27

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 229 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 28 RENAULT_CELL_NUMBER_28

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 228 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 29 RENAULT_CELL_NUMBER_29

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 227 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 30 RENAULT_CELL_NUMBER_30

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 226 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 31 RENAULT_CELL_NUMBER_31

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 225 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 32 RENAULT_CELL_NUMBER_32

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 224 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 33 RENAULT_CELL_NUMBER_33

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 223 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 34 RENAULT_CELL_NUMBER_34

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 222 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 35 RENAULT_CELL_NUMBER_35

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 221 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 36 RENAULT_CELL_NUMBER_36

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 220 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 37 RENAULT_CELL_NUMBER_37

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 219 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 38 RENAULT_CELL_NUMBER_38

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 218 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 39 RENAULT_CELL_NUMBER_39

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 217 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 40 RENAULT_CELL_NUMBER_40

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 216 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 41 RENAULT_CELL_NUMBER_41

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 215 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 42 RENAULT_CELL_NUMBER_42

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 214 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 43 RENAULT_CELL_NUMBER_43

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 213 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 44 RENAULT_CELL_NUMBER_44

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 212 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 45 RENAULT_CELL_NUMBER_45

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 211 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 46 RENAULT_CELL_NUMBER_46

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 210 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 47 RENAULT_CELL_NUMBER_47

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 209 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 48 RENAULT_CELL_NUMBER_48

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 208 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 49 RENAULT_CELL_NUMBER_49

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 50 RENAULT_CELL_NUMBER_50

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 206 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 51 RENAULT_CELL_NUMBER_51

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 205 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 52 RENAULT_CELL_NUMBER_52

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 204 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 53 RENAULT_CELL_NUMBER_53

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 203 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 54 RENAULT_CELL_NUMBER_54

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 202 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 55 RENAULT_CELL_NUMBER_55

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 201 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 56 RENAULT_CELL_NUMBER_56

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 200 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 57 RENAULT_CELL_NUMBER_57

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 199 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 58 RENAULT_CELL_NUMBER_58

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 198 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 59 RENAULT_CELL_NUMBER_59

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 197 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 60 RENAULT_CELL_NUMBER_60

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 196 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 61 RENAULT_CELL_NUMBER_61

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 195 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 62 RENAULT_CELL_NUMBER_62

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 194 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 63 RENAULT_CELL_NUMBER_63

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 193 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 64 RENAULT_CELL_NUMBER_64

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 192 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 65 RENAULT_CELL_NUMBER_65

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 191 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 66 RENAULT_CELL_NUMBER_66

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 190 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 67 RENAULT_CELL_NUMBER_67

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 189 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 68 RENAULT_CELL_NUMBER_68

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 188 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 69 RENAULT_CELL_NUMBER_69

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 187 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 70 RENAULT_CELL_NUMBER_70

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 186 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 71 RENAULT_CELL_NUMBER_71

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 185 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 72 RENAULT_CELL_NUMBER_72

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 184 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 73 RENAULT_CELL_NUMBER_73

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 74 RENAULT_CELL_NUMBER_74

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 75 RENAULT_CELL_NUMBER_75

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 76 RENAULT_CELL_NUMBER_76

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 77 RENAULT_CELL_NUMBER_77

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 78 RENAULT_CELL_NUMBER_78

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 177 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 80 RENAULT_CELL_NUMBER_80

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 176 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 81 RENAULT_CELL_NUMBER_81

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 82 RENAULT_CELL_NUMBER_82

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 174 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 83 RENAULT_CELL_NUMBER_83

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 173 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 84 RENAULT_CELL_NUMBER_84

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 172 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 85 RENAULT_CELL_NUMBER_85

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 86 RENAULT_CELL_NUMBER_86

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 87 RENAULT_CELL_NUMBER_87

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 169 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 88 RENAULT_CELL_NUMBER_88

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 168 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 89 RENAULT_CELL_NUMBER_89

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 167 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 90 RENAULT_CELL_NUMBER_90

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 166 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 91 RENAULT_CELL_NUMBER_91

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 165 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 92 RENAULT_CELL_NUMBER_92

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 164 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 93 RENAULT_CELL_NUMBER_93

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 163 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 94 RENAULT_CELL_NUMBER_94

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 162 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 95 RENAULT_CELL_NUMBER_95

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 161 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

CELL, number 96 RENAULT_CELL_NUMBER_96

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 160 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Cells overvoltage RENAULT_CELLS_OVERVOLAGE

  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Charging station, maximum limited power RENAULT_CHG_STATION_MAX

  • Service 22DID 3006
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 kW
Unit
kW

In testing for 2015 to 2026.

Charging test authorization RENAULT_CHG_TEST

  • Service 22DID 310D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Circuit, current above threshold RENAULT_CIRCUIT_CURRENT

  • Service 22DID 308C
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Climate control power consumed RENAULT_CLIMATE_CTRL_POWER

  • Service 21PID 43
  • Module744 → 764
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 W
Unit
W

In testing for 2015 to 2026.

Climate control power consumed RENAULT_CLIMATE_CTRL_POWER_2

  • Service 22DID 2B79
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 2015 to 2026.

Clutch contact wire connection RENAULT_CLUTCH_CONTACT_WIRE

  • Service 22DID 206D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch pedal switch RENAULT_CLUTCH_PEDAL_SW

  • Service 22DID 222D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch start-of-travel switch RENAULT_CLUTCH_TRAVEL_SW

  • Service 22DID 2059
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Clutch temperature RENAULT_CLUTCH_T

  • Service 22DID 3020
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2015 to 2026.

Combustion mode RENAULT_COMBUSTION_MODE_7E0

  • Service 22DID 2056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Combustion mode setting RENAULT_COMBUSTION_MODE

  • Service 22DID 2055
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Communication, CAN RENAULT_CAN_COMMUNICATION

  • Service 22DID 2391
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2015 to 2026.

Comp. locked RENAULT_COMP_LOCKED

  • Service 21PID 02
  • Module752 → 772
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Comp. locked RENAULT_COMP_LOCKED_752

  • Service 21PID 03
  • Module752 → 772
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Computer + after ignition RENAULT_COMPUTER_AFTER_IGN

  • Service 22DID 200E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Computer + after ignition RENAULT_COMPUTER_AFTER_IGN_V2

  • Service 22DID 1304
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Computer calibration RENAULT_COMPUTER_CALIBRATION

  • Service 21PID 80
  • Module742 → 762
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Computer configuration with air conditioning RENAULT_COMPUTER

  • Service 22DID 2042
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Computer internal temperature RENAULT_COMPUTER_INTERNAL_T_7E1

  • Service 22DID 2205
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 °C
Unit
°C

In testing for 2015 to 2026.

Computer internal temperature RENAULT_COMPUTER_INTERNAL_T_V2

  • Service 22DID 2004
  • Module792
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2015 to 2026.

Computer internal temperature, raw count RENAULT_COMPUTER_INTERNAL_T

  • Service 22DID 2D1A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Computer must be replaced RENAULT_COMPUTER_MUST_BE

  • Service 21PID 03
  • Module752 → 772
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Computer power supply RENAULT_COMPUTER_POWER_SUP

  • Service 22DID 9011
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Computer temperature RENAULT_COMPUTER_T

  • Service 22DID FDDA
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2015 to 2026.

Computer temperature RENAULT_COMPUTER_T_7E1

  • Service 22DID 2366
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191
Unit
Number

In testing for 2015 to 2026.

Computer, current mileage RENAULT_COMPUTER_CURRENT

  • Service 22DID 4B06
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2015 to 2026.

Confirmation for adaptive cruise control request, CAN RENAULT_CAN_CONFIRMATION_ACC

  • Service 22DID 2174
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Consumption measurement units RENAULT_CONS_MEASUREMENT

  • Service 22DID 0105
  • Module743 → 763
  • Every1 s
  • Testing

Bits 6 to 7 of the reply, 2 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2015 to 2026.

Control applied to the driver of the exhaust VVTC solenoid valve, PWM RENAULT_PWM_CTRL_APPLIED

  • Service 22DID 224D
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2015 to 2026.

Controlled coolant thermostat RENAULT_CONTROLLED_CLT

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Controlled coolant thermostat duty cycle RENAULT_CONTROLLED_CLT_2

  • Service 22DID 12A8
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 °
Unit
°

In testing for 2015 to 2026.

Controlled coolant thermostat duty cycle RENAULT_CONTROLLED_CLT_THERMOSTAT

  • Service 22DID 2871
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.3921569
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Coolant flow valve control RENAULT_CLT_FLOW_VLV_CTRL

  • Service 22DID 2264
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Coolant temperature RENAULT_ECT

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 2001
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280.5 °C
Unit
°C

In testing for 2015 to 2026.

Coolant temperature RENAULT_ECT_7E0

  • Service 22DID FD99
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255 °C
Unit
°C

In testing for 2015 to 2026.

Coolant temperature sensor voltage RENAULT_COOLANT_T_SNS_V

  • Service 22DID FD8B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.9997 V
Unit
V

In testing for 2015 to 2026.

Cooling request by injection RENAULT_COOLING_REQ_INJ

  • Service 22DID 25D6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Coupler RENAULT_COUPLER

  • Service 22DID 22B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Coupler RENAULT_COUPLER_V2

  • Service 22DID 3011
  • Module748
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Crank signal RENAULT_CRANK_SIG

  • Service 22DID 2161
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Crankshaft sync loss counter RENAULT_CRANK_SYNC_LOSS_CNT

  • Service 22DID 2162
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Crankshaft synchronization RENAULT_CRANK_SYNC

  • Service 22DID 2016
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cruise control RENAULT_CRUISE_CTRL

  • Service 21PID D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 107 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Cruise control RENAULT_CRUISE_CTRL_2

  • Service 22DID 2079
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Cruise control RENAULT_CRUISE_CTRL_7E0

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cruise control RENAULT_CRUISE_CTRL_7E1

  • Service 22DID 203C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cruise control RENAULT_CRUISE_CTRL_V2

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Cruise control function RENAULT_CRUISE_CTRL_FUNCTION

  • Service 22DID 203A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cruise control function RENAULT_CRUISE_CTRL_FUNCTION_2

  • Service 22DID 203A
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Cruise control setting RENAULT_CRUISE_CTRL_SETTING

  • Service 22DID 2035
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km/h
Unit
km/h

In testing for 2015 to 2026.

Cruise control setting RENAULT_CRUISE_CTRL_SETTING_7E0

  • Service 21PID D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2015 to 2026.

Cruise control setting RENAULT_CRUISE_CTRL_SETTING_V2

  • Service 22DID 2035
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2015 to 2026.

Cruise control, target RENAULT_CRUISE_CTRL_TGT

  • Service 22DID 2035
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2015 to 2026.

Cumulative energy when discharging RENAULT_CUM_ENERGY

  • Service 22DID 9245
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-2147483 to 2147483 kWh
Unit
kWh

In testing for 2015 to 2026.

Current absorbed by the motor RENAULT_CURRENT_ABSORBED

  • Service 21PID 01
  • Module742
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 A
Unit
A

In testing for 2015 to 2026.

Current measured by auxiliary inverter RENAULT_CURRENT_MEAS

  • Service 22DID 3226
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 A
Unit
A

In testing for 2015 to 2026.

Current measured by main inverter RENAULT_CURRENT_MEAS_MAIN

  • Service 22DID 21DA
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 A
Unit
A

In testing for 2015 to 2026.

Curtain side air bag. driver's side RENAULT_CURTAIN_SIDE_AIR_BAG_DRIVER_S_SIDE

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Curtain side air bag. driver's side RENAULT_CURTAIN_SIDE_AIR_BAG_S

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Curtain side air bag. passenger side RENAULT_CURTAIN_SIDE_AIR_BAG

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Curtain side air bag. passenger side RENAULT_CURTAIN_SIDE_AIR_BAG_PASSENGER

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Cylinder 1 combustion misfire counter RENAULT_COMBUSTION_MIS_CNT_1

  • Service 22DID FD7A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Cylinder 1 knock RENAULT_CYL1_KNOCK

  • Service 22DID 2847
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Cylinder 1 knock value RENAULT_CYL_1_KNOCK

  • Service 22DID FD7F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.99 V
Unit
V

In testing for 2015 to 2026.

Cylinder 1 misfire counter RENAULT_CYL1_MISFIRE_CNT

  • Service 22DID 2841
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Cylinder 1 recognition RENAULT_CYL_1_RECOGNITION

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 79 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Cylinder 1 torque failure recognition RENAULT_CYL_1_TQ_FAILURE

  • Service 21PID A9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2015 to 2026.

Cylinder 2 combustion misfire counter RENAULT_COMBUSTION_MIS_CNT_2

  • Service 22DID FD7D
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Cylinder 2 knock RENAULT_CYL2_KNOCK

  • Service 22DID 2848
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Cylinder 2 knock value RENAULT_CYL_2_KNOCK

  • Service 22DID FD7E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.99 V
Unit
V

In testing for 2015 to 2026.

Cylinder 2 misfire counter RENAULT_CYL2_MISFIRE_CNT

  • Service 22DID 2842
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Cylinder 3 advance correction RENAULT_CYL_3_ADVANCE_CORR

  • Service 22DID FD85
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.99 V
Unit
V

In testing for 2015 to 2026.

Cylinder 3 combustion misfire counter RENAULT_COMBUSTION_MIS_CNT_3

  • Service 22DID FD7B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Cylinder 3 knock RENAULT_CYL3_KNOCK

  • Service 22DID 2849
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Cylinder 3 misfire counter RENAULT_CYL3_MISFIRE_CNT

  • Service 22DID 2843
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Cylinder 4 advance correction RENAULT_CYL_4_ADVANCE_CORR

  • Service 22DID FD86
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.99 V
Unit
V

In testing for 2015 to 2026.

Cylinder 4 combustion misfire counter RENAULT_COMBUSTION_MIS_CNT_4

  • Service 22DID FD7C
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Cylinder 4 knock RENAULT_CYL4_KNOCK

  • Service 22DID 284A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Cylinder 4 misfire counter RENAULT_CYL4_MISFIRE_CNT

  • Service 22DID 2844
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Damper valve set point position RENAULT_DAMPER_VLV_SETPOINT

  • Service 22DID 2405
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250−1599.054
Range
-1599 to 1599 %
Unit
%

In testing for 2015 to 2026.

Damper valve set point position RENAULT_DAMPER_VLV_SETPOINT_POS

  • Service 21PID A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 152 to 167 of the reply, 16 bits. The value is signed.

Formula
val×0.01220703
Range
-399 to 399 %
Unit
%

In testing for 2015 to 2026.

Damper valve upstream temperature RENAULT_DAMPER_VLV_UP_T

  • Service 22DID 244D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Dcdc input, current RENAULT_DCDC_INPUT_CURRENT

  • Service 22DID 20B5
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32767
Range
-32767 to 32768 A
Unit
A

In testing for 2015 to 2026.

Dcdc load RENAULT_DCDC_LOAD

  • Service 22DID 29FA
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Dcdc status RENAULT_DCDC_STAT

  • Service 22DID 20B4
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Deadlocking RENAULT_DEADLOCKING

  • Service 21PID 13
  • Module745 → 765
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Deceleration RENAULT_DECELERATION

  • Service 22DID 1116
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×311000
Range
-3.96 to 3.93 g
Unit
g

In testing for 2015 to 2026.

Deceleration without brake depressed RENAULT_DECELERATION_WITHOUT

  • Service 22DID 204F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Deceleration without brake depressed RENAULT_DECELERATION_WITHOUT_V2

  • Service 22DID 204F
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Direction motor temperature RENAULT_DIRECTION_MOTOR_T

  • Service 21PID 01
  • Module742
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2015 to 2026.

Display circuit RENAULT_DISPLAY_CIRCUIT

  • Service 22DID 20C3
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Double loop adaptive RENAULT_DOUBLE_LOOP_ADAPTIVE

  • Service 22DID 2573
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val98304−0.333333
Range
-0.333 to 0.333
Unit
Number

In testing for 2015 to 2026.

Double richness loop RENAULT_DOUBLE_RICHNESS_LOOP

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 74 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Downstream heating sensor control setting RENAULT_DN_HEATING_SENS_CTRL

  • Service 22DID 24C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Downstream O2 sensor heat resistance RENAULT_DN_O2_SENS_HEAT_RES

  • Service 22DID FD8E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100
Range
0 to 2.55 Ω
Unit
Ω

In testing for 2015 to 2026.

Downstream oxygen rate RENAULT_DN_OXYGEN_RATE

  • Service 22DID FE73
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100000
Range
-0.327 to 0.327
Unit
Number

In testing for 2015 to 2026.

Downstream oxygen sensor RENAULT_DN_OXYGEN_SENS

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Downstream oxygen sensor heating RENAULT_DN_OXYGEN_SENS_2

  • Service 22DID 130B
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Downstream oxygen sensor heating RENAULT_DN_OXYGEN_SENS_V2

  • Service 22DID 2507
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Downstream oxygen sensor reset RENAULT_DN_OXYGEN_SENS_RESET

  • Service 22DID FE69
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Downstream sensor heating OCR RENAULT_DN_SENS_HEATING_OCR

  • Service 22DID 244C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 85 %
Unit
%

In testing for 2015 to 2026.

Drain cut valve diagnosis RENAULT_DRAIN_CUT_VLV

  • Service 22DID 251C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 2015 to 2026.

Driver front air bag circuit 1 RENAULT_DRIVER_FRONT_AIR_BAG_1

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Driver front air bag circuit 1 RENAULT_DRIVER_FRONT_AIR_BAG_CIRCUIT_1

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Driver front air bag circuit 2 RENAULT_DRIVER_FRONT_AIR_BAG_2

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Driver front air bag circuit 2 RENAULT_DRIVER_FRONT_AIR_BAG_CIRCUIT_2

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Driver's lap strap/seat airbag RENAULT_DRIVER_S_LAP_STRAP

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Driver's lap strap/seat airbag RENAULT_DRIVER_S_LAP_STRAP_SEAT

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Driver's lateral sensor RENAULT_DRIVER_S_LATERAL

  • Service 21PID 09
  • Module752 → 772
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Driver's seat buckle sensor RENAULT_DRIVER_S_SEAT_BUCKLE

  • Service 21PID 09
  • Module752 → 772
  • Every1 s
  • Testing

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Driver's seat position sensor RENAULT_DRIVER_S_SEAT_POS

  • Service 21PID 09
  • Module752 → 772
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Driver's side rear strap sensor RENAULT_DRIVER_S_SIDE_REAR

  • Service 21PID 09
  • Module752 → 772
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Driver's wishes estimated engine torque RENAULT_DRIVER_S_WISHES

  • Service 21PID A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2015 to 2026.

Duration of - button press RENAULT_DUR_BUTTON_PRESS_7E0

  • Service 22DID 207C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2015 to 2026.

Duration of + button press RENAULT_DUR_BUTTON_PRESS

  • Service 22DID 207B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2015 to 2026.

Duration of last regeneration RENAULT_DUR_LAST_REGEN

  • Service 22DID 2487
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 s
Unit
s

In testing for 2015 to 2026.

Duration of resume button press RENAULT_DUR_RESUME_BUTTON

  • Service 22DID 207A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2015 to 2026.

Duration of resume button press RENAULT_DUR_RESUME_BUTTON_2

  • Service 22DID 207A
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 s
Unit
s

In testing for 2015 to 2026.

Duration of suspend button press RENAULT_DUR_SUSPEND_BUTTON

  • Service 22DID 207D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2015 to 2026.

Duration of suspend button press RENAULT_DUR_SUSPEND_BUTTON_2

  • Service 22DID 207D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 s
Unit
s

In testing for 2015 to 2026.

Earth resistance RENAULT_EARTH_RES

  • Service 22DID 5062
  • Module792
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 Ω
Unit
Ω

In testing for 2015 to 2026.

Effective engine torque RENAULT_EFFECTIVE_ENG_TQ

  • Service 22DID 2037
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Effective engine torque RENAULT_EFFECTIVE_ENG_TQ_7E1

  • Service 22DID 111B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×325
Range
-819 to 812 N·m
Unit
N·m

In testing for 2015 to 2026.

Effective mean torque multiplexed information RENAULT_EFFECTIVE_MEAN_TQ

  • Service 22DID 20F1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Electric motor interlocks RENAULT_ELEC_MOTOR

  • Service 22DID 314D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Electric water pump RENAULT_ELEC_WATER_PMP

  • Service 22DID 2897
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Electrical damper AT stop RENAULT_ELECTRICAL_DAMPER

  • Service 21PID 08
  • Module742 → 762
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Electronic brake force distribution RENAULT_EBD

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Electronic brake force distribution, warning RENAULT_EBD_WARN

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Emergency braking anticipation RENAULT_EBA_ANT

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Emergency braking anticipation function RENAULT_EMERGENCY_BRAKING

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Emergency braking anticipation function RENAULT_EMERGENCY_BRAKING_ANTICIPATION

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Emergency braking anticipation, warning RENAULT_EBA_ANT_WARN

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Emergency braking assistance RENAULT_EBA_ASSIST

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Emergency braking assistance function RENAULT_EMERGENCY_BRAKING_ASSISTANCE

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Emergency braking assistance, warning RENAULT_EBA_ASSIST_WARN

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Energy control unit RENAULT_ENERGY_CTRL_UNIT

  • Service 22DID 216F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engine air flow RENAULT_ENG_AIR_FLOW

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2015 to 2026.

Engine air load RENAULT_ENG_AIR_LOAD

  • Service 22DID 245E
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000610352
Range
0 to 3.99
Unit
Number

In testing for 2015 to 2026.

Engine immobiliser RENAULT_ENG_IMMOBILISER_V2

  • Service 22DID 202D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engine immobilizer RENAULT_ENG_IMMOBILISER

  • Service 21PID AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Engine immobilizer RENAULT_ENG_IMMOBILISER_7E0

  • Service 22DID 202D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Engine load RENAULT_ENG_LOAD

  • Service 22DID 245E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16384
Range
0 to 3.99
Unit
Number

In testing for 2015 to 2026.

Engine off information RENAULT_ENG_OFF_INFORMATION

  • Service 22DID FD95
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2015 to 2026.

Engine oil dilution ratio RENAULT_ENG_OIL_DILUTION_RAT

  • Service 22DID 2294
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×4.7e-9+10
Range
0 to 19.99 %
Unit
%

In testing for 2015 to 2026.

Engine oil dilution ratio RENAULT_ENG_OIL_DILUTION_RAT_7E0

  • Service 22DID 24EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000000
Range
0 to 4294 %
Unit
%

In testing for 2015 to 2026.

Engine oil temperature, estimated RENAULT_EST_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 2007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280.5 °C
Unit
°C

In testing for 2015 to 2026.

Engine on time since the last regeneration RENAULT_ENG_ON_TIME_SINCE

  • Service 22DID 30DD
  • ModuleDA15 → 15
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val360000
Range
-5965 to 5965 h
Unit
h

In testing for 2015 to 2026.

Engine operating phase RENAULT_ENG_OP_PHASE

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engine operation time since the last successful regeneration RENAULT_ENG_OPERATION_TIME

  • Service 22DID 30DE
  • ModuleDA15 → 15
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 h
Unit
h

In testing for 2015 to 2026.

Engine rotation count RENAULT_ENGINE_ROT_COUNT

  • Service 22DID 210E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000000
Range
0 to 4294.9672
Unit
Number

In testing for 2015 to 2026.

Engine running RENAULT_ENG_RUNNING

  • Service 22DID 2E36
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engine running. RENAULT_ENG_RUNNING_V2

  • Service 22DID 0049
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engine status RENAULT_ENG_STAT

  • Service 22DID 2E36
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engine status RENAULT_ENG_STAT_7E1

  • Service 22DID 2349
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2015 to 2026.

Engine status RENAULT_ENG_STAT_7E1_V2

  • Service 22DID 004A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engine status RENAULT_ENG_STAT_V2

  • Service 22DID 0048
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engine torque RENAULT_ENG_TQ

  • Service 21PID A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2015 to 2026.

Engine torque RENAULT_ENG_TQ_7E1

  • Service 22DID 2004
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Engine torque RENAULT_ENG_TQ_V2

  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−400
Range
-400 to 1647 N·m
Unit
N·m

In testing for 2015 to 2026.

Engine torque RENAULT_ENGINE_TORQUE

  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−400
Range
-400 to 1647.9687 N·m
Unit
N·m

In testing for 2015 to 2026.

Engine torque control RENAULT_TORQUE_CTRL

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Engine torque control, warning RENAULT_TORQUE_CTRL_WARN

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Engine torque reference value RENAULT_ENG_TQ_REFERENCE

  • Service 22DID 2069
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047 N·m
Unit
N·m

In testing for 2015 to 2026.

Engine torque, reference RENAULT_ENGINE_TORQUE_REF

  • Service 22DID 3011
  • Module748
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2−400
Range
-16784 to 15983.5 N·m
Unit
N·m

In testing for 2015 to 2026.

Engine type RENAULT_ENG_TYPE

  • Service 21PID 02
  • Module74D → 76D
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

ESP, deactivated RENAULT_ESP_OFF

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Estimated air flow RENAULT_ESTIMATED_AIR_FLOW

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2015 to 2026.

Estimated air flow RENAULT_ESTIMATED_AIR_FLOW_V2

  • Service 22DID 2421
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2015 to 2026.

Estimated engine oil temperature RENAULT_ESTIMATED_EOT

  • Service 22DID 2007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Estimated manifold pressure RENAULT_ESTIMATED_MANIFOLD_P

  • Service 22DID 2533
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Ethanol percentage AT the injector RENAULT_ETHANOL_PERCENTAGE

  • Service 22DID FE25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val128
Range
0 to 1.99
Unit
Number

In testing for 2015 to 2026.

Ethanol sensor signal frequency RENAULT_ETHANOL_SENS_SIG

  • Service 22DID FD20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 Hz
Unit
Hz

In testing for 2015 to 2026.

Evaporation system pressure RENAULT_EVAPORATION_SYSTEM_P

  • Service 22DID F432
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val400
Range
0 to 163
Unit
Raw value

In testing for 2015 to 2026.

Evaporation system pressure RENAULT_EVAPORATION_SYSTEM_P_2

  • Service 22DID 1115
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2015 to 2026.

Evaporation system pressure RENAULT_EVAPORATION_SYSTEM_P_7E0

  • Service 22DID F453
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20000
Range
0 to 3.27 bar
Unit
bar

In testing for 2015 to 2026.

Evaporation system pressure RENAULT_EVAPORATION_SYSTEM_P_7E0_V2

  • Service 22DID F454
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2015 to 2026.

Evaporation system pressure RENAULT_EVAPORATION_SYSTEM_P_V2

  • Service 22DID FD42
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Raw value

In testing for 2015 to 2026.

Evaporator temperature RENAULT_EVAPORATOR_T

  • Service 21PID 21
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2015 to 2026.

Exhaust air flap OCR RENAULT_EXH_AIR_FLAP_OCR

  • Service 22DID 2569
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Exhaust air flap offset RENAULT_EXH_AIR_FLAP_OFFSET

  • Service 22DID 256C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2015 to 2026.

Exhaust air flap position RENAULT_EXH_AIR_FLAP_POS

  • Service 22DID 25D9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Exhaust air flap position RENAULT_EXH_AIR_FLAP_POS_V2

  • Service 22DID 256B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2505123
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Exhaust camshaft phasing RENAULT_EXH_CAM_PHASING

  • Service 22DID 224F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310
Unit
Number

In testing for 2015 to 2026.

Exhaust camshaft position RENAULT_EXH_CAM_POS

  • Service 22DID FDB8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 °
Unit
°

In testing for 2015 to 2026.

Exhaust flap absolute position RENAULT_EXH_FLAP_ABS_POS

  • Service 22DID 256F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2505123
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Exhaust flap high setting RENAULT_EXH_FLAP_HIGH

  • Service 22DID 2572
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Exhaust flap low setting RENAULT_EXH_FLAP_LOW_SETTING

  • Service 22DID 2571
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Exhaust flap position set point RENAULT_EXH_FLAP_POS

  • Service 22DID 25D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Exhaust flap position set point RENAULT_EXH_FLAP_POS_V2

  • Service 22DID 256A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250−1599.054
Range
-1599 to 1599 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas flow RENAULT_EXH_GAS_FLOW

  • Service 22DID 30B3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276
Unit
Raw value

In testing for 2015 to 2026.

Exhaust gas recirculation FUNCTION PROGRAMMING RENAULT_EGR_FUNCTION

  • Service 22DID 2479
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Exhaust gas recirculation LOW PRESSURE OCR RENAULT_EGR_LOW_P_OCR

  • Service 22DID 2567
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas recirculation LOW PRESSURE POSITION RENAULT_EGR_LOW_P_POS

  • Service 22DID 2564
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas recirculation LOW PRESSURE POSITION RENAULT_EGR_LOW_P_POS_7E0

  • Service 22DID 2561
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas recirculation LOW PRESSURE POTENTIOMETER RENAULT_EGR_LOW_P

  • Service 22DID FDBD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

In testing for 2015 to 2026.

Exhaust gas recirculation POSITION RENAULT_EGR_POS

  • Service 22DID 2407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas recirculation SOLENOID VALVE CONTROL RENAULT_EGR_SOLENOID_VLV

  • Service 22DID 246E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.67
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas recirculation VALVE CONTROL RENAULT_EGR_VLV_CTRL

  • Service 22DID 1112
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Number

In testing for 2015 to 2026.

Exhaust gas recirculation VALVE CONTROL RENAULT_EGR_VLV_CTRL_V2

  • Service 22DID 2409
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas recirculation VALVE FIRST OFFSET RENAULT_EGR_VLV_FIRST_OFFSET

  • Service 22DID 242A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas recirculation VALVE FIRST OFFSET RENAULT_EGR_VLV_FIRST_OFFSET_7E0

  • Service 21PID 64
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits.

Formula
val×0.01220703
Range
0 to 799 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas recirculation VALVE OPENING REFERENCE RENAULT_EGR_VLV_OPENING

  • Service 22DID 2408
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas recirculation VALVE OPENING REFERENCE RENAULT_EGR_VLV_OPENING_REFERENCE

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val×0.01220703
Range
-399 to 399 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas recirculation VALVE POSITION RECOPY RENAULT_EGR_VLV_POS_RECOPY

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.01220703
Range
-399 to 399 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas recirculation VALVE POSITION RECOPY LOOP DIFFERENCE RENAULT_EGR_VLV_POS_RECOPY_LOOP

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val×0.01220703
Range
-399 to 399 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas recirculation VALVE RCO RENAULT_EGR_VLV_RCO

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Exhaust gas temperature RENAULT_EXH_GAS_T

  • Service 22DID 243B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Exhaust gas temperature sensor RENAULT_EXH_GAS_T_SENS

  • Service 22DID 30B2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4−40
Range
-40 to 980 °C
Unit
°C

In testing for 2015 to 2026.

Exhaust gas temperature sensor RENAULT_EXH_GAS_T_SENS_V2

  • Service 22DID 24F3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Exhaust system flow RENAULT_EXH_SYSTEM_FLOW

  • Service 22DID FE14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2015 to 2026.

Exhaust system flow RENAULT_EXH_SYSTEM_FLOW_V2

  • Service 22DID 24E2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100000
Range
0 to 0.655 g/s
Unit
g/s

In testing for 2015 to 2026.

Exhaust temperature RENAULT_EXH_T

  • Service 22DID 30B2
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 °C
Unit
°C

In testing for 2015 to 2026.

External air temperature RENAULT_EXTERNAL_AIR_T

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The value is signed.

Formula
val10−273
Range
-3549 to 3003 °C
Unit
°C

In testing for 2015 to 2026.

External air temperature RENAULT_EXTERNAL_AIR_T_7E1

  • Service 22DID 233B
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 °C
Unit
°C

In testing for 2015 to 2026.

External air temperature RENAULT_EXTERNAL_AIR_T_V2

  • Service 22DID 2E30
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2015 to 2026.

External temperature RENAULT_EXTERNAL_T

  • Service 21PID C1
  • Module745 → 765
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

External temperature RENAULT_EXTERNAL_T_744

  • Service 21PID 43
  • Module744 → 764
  • Every5 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2015 to 2026.

EXTERNAL TEMPERATURE, raw count RENAULT_EXTERNAL_T_RAW_CNT

  • Service 21PID 43
  • Module744 → 764
  • Every5 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Fan high speed request RENAULT_FAN_HI_SPD

  • Service 22DID 204A
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fan unit RENAULT_FAN_UNIT

  • Service 22DID 91EF
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Fan unit RENAULT_FAN_UNIT_2

  • Service 22DID 1178
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Fan unit feed RENAULT_FAN_UNIT_FEED

  • Service 22DID 925A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 Hz
Unit
Hz

In testing for 2015 to 2026.

Fast idle request for heating resistors RENAULT_FAST_IDLE_REQ_PCHR

  • Service 21PID C1
  • Module745 → 765
  • Every5 s
  • Testing

Bit 64 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Fault appearance counter RENAULT_FAULT_APPEARANCE_CNT

  • Service 22DID 2203
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Fault finding version RENAULT_FAULT_FINDING

  • Service 21PID 80
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fault finding version RENAULT_FAULT_FINDING_2

  • Service 22DID F1A0
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fault finding version RENAULT_FAULT_FINDING_VERSION

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fault finding version RENAULT_FAULT_FINDING_VERSION_7E1

  • Service 21PID 80
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fault finding version RENAULT_FAULT_FINDING_VERSION_7E1_2

  • Service 22DID F1A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fault finding version RENAULT_FAULT_FINDING_VERSION_DADB

  • Service 22DID F1A0
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fault type RENAULT_FAULT_TYPE

  • Service 22DID 3153
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Fault/s memorized RENAULT_FAULT_S_MEMORISED

  • Service 21PID 03
  • Module752 → 772
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Filtered angular position of the exhaust VVTC system RENAULT_FILTERED_ANGULAR_POS

  • Service 22DID 2255
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310
Unit
Number

In testing for 2015 to 2026.

Filtered boost pressure RENAULT_FILTERED_BOOST_P

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2015 to 2026.

Final alcohol adaptive RENAULT_FINAL_ALCOHOL

  • Service 22DID 287B
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.001525902
Range
0 to 99.99 %
Unit
%

In testing for 2015 to 2026.

First offset damper valve closed RENAULT_FIRST_OFFSET_DAMPER_VLV

  • Service 22DID 2427
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

First offset damper valve open RENAULT_FIRST_OFFSET_DAMPER

  • Service 22DID 2425
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

First offset of the closed exhaust flap RENAULT_FIRST_OFFSET_CLOSED

  • Service 22DID 256D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2015 to 2026.

First offset of the closed swirl valve RENAULT_FIRST_OFFSET_CLOSED_SWIRL

  • Service 22DID 2589
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2505123
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

First offset of the exhaust air flap open RENAULT_FIRST_OFFSET_EXH_AIR

  • Service 22DID 2578
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2015 to 2026.

First offset of the open swirl valve RENAULT_FIRST_OFFSET_OPEN

  • Service 22DID 258D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2505123
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

First offset valve closed RENAULT_FIRST_OFFSET_VLV

  • Service 22DID 25D3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

First start RENAULT_FIRST_START

  • Service 22DID 2047
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

First start RENAULT_FIRST_START_7E0

  • Service 22DID 251F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

First start RENAULT_FIRST_START_DADA

  • Service 22DID 251F
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Flow of gas inside the particle filter RENAULT_FLOW_GAS_INSIDE

  • Service 22DID 30B3
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Flow of gas inside the particle filter RENAULT_FLOW_GAS_INSIDE_V2

  • Service 22DID 2447
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2015 to 2026.

Flow regulator, current reference value RENAULT_FLOW_REGULATOR

  • Service 22DID FDEA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 2015 to 2026.

Fluid pressure sensor configuration RENAULT_FLUID_P_SENS

  • Service 22DID 2043
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Flywheel target programming RENAULT_FLYWHEEL_TGT_PROG

  • Service 22DID 215B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Foot distribution motor set point RENAULT_FOOT_DISTRIBUTION

  • Service 21PID 27
  • Module744 → 764
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Foot well and vent distribution flap position RENAULT_FOOTWELL_VENT

  • Service 21PID 27
  • Module744 → 764
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Front fog lights request RENAULT_FRONT_FOG_LIGHTS_REQ

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 77 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Front panel air inlet control flap duty cycle RENAULT_FRONT_PANEL_AIR

  • Service 22DID 28C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.3921569
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Front thorax side air bag. driver side RENAULT_FRONT_THORAX_SIDE_AIR_BAG

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Front thorax side air bag. driver side RENAULT_FRONT_THORAX_SIDE_AIR_BAG_DRIVER

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Front thorax side air bag. passenger side RENAULT_FRONT_THORAX_SIDE

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Front thorax side air bag. passenger side RENAULT_FRONT_THORAX_SIDE_AIR_BAG_PASSENGER_SIDE

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Front wiper information RENAULT_FRONT_WIPER

  • Service 21PID 10
  • Module74D → 76D
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fuel level, low RENAULT_LOW_FUEL

  • Service 22DID 281B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fuel pump control circuit RENAULT_FUEL_PUMP_CTRL

  • Service 22DID 281C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fule regulation solenoid valve RCO RENAULT_FULE_REGULATION

  • Service 21PID A6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Gas mode RENAULT_GAS_MODE

  • Service 22DID 28AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Gas temperature RENAULT_GAS_T_7E0

  • Service 22DID FE19
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 ms
Unit
ms

In testing for 2015 to 2026.

Gross engine torque RENAULT_GROSS_ENG_TQ

  • Service 22DID 2067
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047 N·m
Unit
N·m

In testing for 2015 to 2026.

Gross inlet manifold pressure RENAULT_GROSS_INLET_MANIFOLD_P

  • Service 22DID 2533
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Hands-free parking control RENAULT_HANDS_FREE_PARKING

  • Service 22DID 2B19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Hazard warning lights button RENAULT_HAZARD_WARN_LIGHTS

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Headlight on request by brightness sensor RENAULT_HEADLIGHT_ON_REQ

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Headlight washers RENAULT_HEADLIGHT_WASHERS

  • Service 21PID 10
  • Module74D → 76D
  • Every5 s
  • Testing

Bit 89 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Heated oxygen sensor signal RENAULT_HEATED_OXYGEN_SENS

  • Service 22DID FD28
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Heated oxygen sensor temperature signal RENAULT_HEATED_OXYGEN_SENS_T

  • Service 22DID FD2A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Heated rear screen control RENAULT_HEATED_REAR_SCREEN

  • Service 21PID C1
  • Module745 → 765
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Heater fan switch RENAULT_HEATER_FAN_SWITCH

  • Service 22DID 1304
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Heater plug control RENAULT_HEATER_PLUG_CTRL

  • Service 22DID 20FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Heater plug control RENAULT_HEATER_PLUG_CTRL_V2

  • Service 22DID 2052
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Heater water pump RENAULT_HEATER_WATER_PMP

  • Service 22DID 2B75
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Heating resistor interlock RENAULT_HEATING_RESISTOR_INTERLOCK

  • Service 22DID 314D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Heating resistor power consumed RENAULT_HEATING_RESISTOR_2

  • Service 22DID 314F
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×250
Range
0 to 63750 W
Unit
W

In testing for 2015 to 2026.

Heating resistor type RENAULT_HEATING_RESISTOR

  • Service 21PID 04
  • Module744 → 764
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Heating resistors active count RENAULT_HEAT_RESISTOR_CNT

  • Service 22DID 218D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Heating resistors authorized by alternator RENAULT_PCHR_NUMBER_AUTHORISED

  • Service 21PID C1
  • Module745 → 765
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Heating resistors authorized by injection RENAULT_PCHR_NUMBER

  • Service 21PID C1
  • Module745 → 765
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Heating resistors controlled RENAULT_PCHR_NUMBER_CONTROLLED

  • Service 21PID C1
  • Module745 → 765
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

High pressure compressor bypass sol valve RENAULT_HIGH_P_COMP_BYPASS

  • Service 22DID 2532
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

High pressure pump counter RENAULT_HIGH_P_PMP_CNT

  • Service 22DID 22AB
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2015 to 2026.

High selection threshold RENAULT_HIGH_SELECTION_THR

  • Service 22DID 2B46
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

High volatge locked out by clip RENAULT_HIGH_VOLATGE_LOCKED

  • Service 22DID 2ADC
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

High voltage thermal accessory interlock RENAULT_HIGH_V_THERMAL

  • Service 22DID 314D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Hill descent control switch RENAULT_HILL_DESCENT_CTRL

  • Service 22DID 4B0F
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Hill start RENAULT_HILL_START_7E0

  • Service 22DID 2B19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Hill start RENAULT_HILL_START_7E0_2

  • Service 22DID 2B0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Hill start assist RENAULT_HILL_START

  • Service 22DID 4B31
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Humidity RENAULT_HUMIDITY

  • Service 21PID 21
  • Module744 → 764
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2015 to 2026.

Hvb coolant temperature RENAULT_HVB_ECT

  • Service 22DID 3045
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Hydraulic unit temperature RENAULT_HYD_T

  • Service 22DID 4B17
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2015 to 2026.

Idle adaptive correction RENAULT_IDLE_ADAPT_CORR

  • Service 22DID 209A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.9687 N·m
Unit
N·m

In testing for 2015 to 2026.

Idle adaptive correction RENAULT_IDLE_ADAPTIVE_CORR

  • Service 22DID 209A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−1024
Range
-1024 to 1023 N·m
Unit
N·m

In testing for 2015 to 2026.

Idle air volume learning RENAULT_IDLE_AIR_VOLUME

  • Service 22DID 1305
  • ModuleDADA → DA
  • Every3600 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Idle control RENAULT_IDLE_CTRL

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 73 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Idle regulation integral correction RENAULT_IDLE_REG_INT_CORR

  • Service 22DID 2246
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.9687 N·m
Unit
N·m

In testing for 2015 to 2026.

Idle regulation integral correction RENAULT_IDLE_REGULATION

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×16
Range
0 to 4080 rpm
Unit
rpm

In testing for 2015 to 2026.

Idle regulation integral correction RENAULT_IDLE_REGULATION_V2

  • Service 22DID 2246
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−1024
Range
-1024 to 1023 N·m
Unit
N·m

In testing for 2015 to 2026.

Idle regulation programming value RENAULT_IDLE_REGULATION_PROGRAMMING

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val×2013107
Range
-50 to 49.99 %
Unit
%

In testing for 2015 to 2026.

Idle regulation valve reference value RENAULT_IDLE_REGULATION_VLV

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2015 to 2026.

Ignition advance RENAULT_IGN_ADVANCE

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×38−23.625
Range
-23.62 to 72 °
Unit
°

In testing for 2015 to 2026.

Ignition advance RENAULT_IGN_ADVANCE_2

  • Service 22DID 116D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2015 to 2026.

Ignition advance RENAULT_IGN_ADVANCE_V2

  • Service 22DID 2807
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val3−23.625
Range
-23.62 to 61.37 °
Unit
°

In testing for 2015 to 2026.

Ignition relay on RENAULT_IGN

  • Service 22DID 60C6
  • Module745 → 765
  • Every3 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Ignition timing advance RENAULT_IGN_TIMING_ADV

  • Service 22DID 2807
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2015 to 2026.

Image of engine torque RENAULT_IMAGE_ENG_TQ

  • Service 22DID 2190
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Immobilizer code programmed RENAULT_IMMOBILISER_CODE

  • Service 21PID AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Impact detected RENAULT_IMPACT_DETECTED

  • Service 21PID 02
  • Module752 → 772
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Impact detected RENAULT_IMPACT_DETECTED_7E0

  • Service 21PID AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Impact detected RENAULT_IMPACT_DETECTED_7E0_2

  • Service 22DID 2090
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Improved grip RENAULT_GRIP_CTRL

  • Service 22DID 4B47
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Incoherence RENAULT_INCOHERENCE

  • Service 22DID 21F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Injection connection, LPG RENAULT_LPG_INJ_CONNECTION

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Injection duration RENAULT_INJ_DUR

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4
Range
0 to 262140 ms
Unit
ms

In testing for 2015 to 2026.

Injection duration RENAULT_INJ_DUR_2

  • Service 22DID 1208
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127 ms
Unit
ms

In testing for 2015 to 2026.

Injection duration RENAULT_INJ_DUR_V2

  • Service 22DID 2804
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val×4
Range
0 to 67108860 ms
Unit
ms

In testing for 2015 to 2026.

Inlet air flow RENAULT_INLET_AIR_FLOW

  • Service 22DID 2412
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2015 to 2026.

Inlet air temperature RENAULT_INLET_AIR_T

  • Service 22DID 243F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280.5 °C
Unit
°C

In testing for 2015 to 2026.

Inlet air temperature RENAULT_INLET_AIR_T_7E0

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The value is signed.

Formula
val10−273
Range
-3549 to 3003 °C
Unit
°C

In testing for 2015 to 2026.

Inlet air temperature RENAULT_INLET_AIR_T_7E0_V2

  • Service 22DID 240D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Inlet air temperature RENAULT_INLET_AIR_T_DADA

  • Service 22DID 1106
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2015 to 2026.

Inlet camshaft dephaser control duty cycle RENAULT_IN_CAM_DEPHASER_OCR

  • Service 22DID 2033
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2015 to 2026.

Inlet camshaft dephaser control duty cycle RENAULT_INLET_CAM_DEPHASER

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val×25256
Range
0 to 6399 %
Unit
%

In testing for 2015 to 2026.

Inlet camshaft dephaser set point RENAULT_IN_CAM_DEPHASER_SETPT

  • Service 22DID 2030
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 °
Unit
°

In testing for 2015 to 2026.

Inlet camshaft dephaser set point RENAULT_INLET_CAM_DEPHASER_V2

  • Service 22DID 2030
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310
Unit
Number

In testing for 2015 to 2026.

Inlet camshaft dephaser solenoid programming RENAULT_IN_CAM_DEPHASER_SOL_PROG

  • Service 22DID 2241
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Inlet camshaft dephasing RENAULT_IN_CAM_DEPHASING

  • Service 22DID 2031
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 °
Unit
°

In testing for 2015 to 2026.

Inlet camshaft dephasing RENAULT_INLET_CAM_DEPHASING

  • Service 22DID 2031
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310
Unit
Number

In testing for 2015 to 2026.

Inlet camshaft position RENAULT_INLET_CAM_POS

  • Service 22DID FDB7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 °
Unit
°

In testing for 2015 to 2026.

Inlet camshaft position RENAULT_INLET_CAM_POS_2

  • Service 22DID 1135
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5
Unit
Number

In testing for 2015 to 2026.

Inlet flap control RENAULT_INLET_FLAP_CTRL

  • Service 22DID 2406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Inlet throttle upstream temperature RENAULT_INLET_THROTTLE_UP_T

  • Service 22DID 244D
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Insulation resistance threshold RENAULT_INSULATION_RES_THR

  • Service 22DID 314C
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Insulation resistance value RENAULT_INSULATION_RES

  • Service 22DID 303D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100
Range
0 to 6553500 Ω
Unit
Ω

In testing for 2015 to 2026.

Interlock safety lockout plug RENAULT_INTERLOCK_SAFETY

  • Service 22DID 314D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Internal fault code RENAULT_INT_FAULT_CODE

  • Service 22DID 302D
  • Module748
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2015 to 2026.

Internal temperature RENAULT_INTERNAL_T

  • Service 21PID 21
  • Module744 → 764
  • Every5 s
  • Testing

Bits 10 to 19 of the reply, 10 bits.

Formula
val10−40
Range
-40 to 62.3 °C
Unit
°C

In testing for 2015 to 2026.

Internal temperature sensor circuit RENAULT_INTERNAL_T_SENS

  • Service 22DID 251D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Internal temperature sensor circuit RENAULT_INTERNAL_T_SENS_V2

  • Service 22DID 2515
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Inverter state RENAULT_INVERTER_ST

  • Service 22DID 221D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Inverter water temperature RENAULT_INVERTER_WATER_T

  • Service 22DID 306C
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Kick down RENAULT_KICK_DOWN

  • Service 22DID 2C2C
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Kick down RENAULT_KICK_DOWN_V2

  • Service 22DID 2C2C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Km after replacing the particle filter RENAULT_KM_AFTER_REPLACING

  • Service 22DID 24BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Km since last successful regeneration RENAULT_KM_SINCE_SUCCESSFUL

  • Service 22DID 30E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647 m
Unit
m

In testing for 2015 to 2026.

Km since last successful regeneration RENAULT_KM_SINCE_SUCCESSFUL_REGEN

  • Service 22DID 30DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647 m
Unit
m

In testing for 2015 to 2026.

Km since last successful regeneration RENAULT_KM_SINCE_SUCCESSFUL_V2

  • Service 22DID 24A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Knock signal, average RENAULT_KNOCK_AVG

  • Service 22DID 284D
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Lambda value RENAULT_LAMBDA

  • Service 22DID 28C5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

In testing for 2015 to 2026.

Lambda value RENAULT_LAMBDA_7E0

  • Service 22DID FD27
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0002441
Range
0 to 15.99
Unit
Number

In testing for 2015 to 2026.

Lambda value RENAULT_LAMBDA_7E0_V2

  • Service 22DID FD70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.99
Unit
Number

In testing for 2015 to 2026.

Last adaptive value programmed RENAULT_LAST_ADAPTIVE

  • Service 22DID 21BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Last EGR valve offset RENAULT_LAST_EGR_VLV_OFFSET

  • Service 22DID 2429
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Last EGR valve offset RENAULT_LAST_EGR_VLV_OFFSET_7E0

  • Service 21PID 64
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits.

Formula
val×0.01220703
Range
0 to 799 %
Unit
%

In testing for 2015 to 2026.

Last offset damper valve closed RENAULT_LAST_OFFSET_DAMPER

  • Service 22DID 2428
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Last offset damper valve open RENAULT_LAST_OFFSET_DAMPER_VLV

  • Service 22DID 2426
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Last offset of closed low pressure EGR RENAULT_LAST_OFFSET_CLOSED_P

  • Service 22DID 2562
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Last offset of the closed swirl valve RENAULT_LAST_OFFSET_CLOSED

  • Service 22DID 258B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2505123
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Last offset valve closed RENAULT_LAST_OFFSET_VLV

  • Service 22DID 25CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Last service RENAULT_LAST_SERVICE

  • Service 21PID 6A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 1 RENAULT_LAUNCH_CTRL_1

  • Service 22DID 2DE1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-21474836 to 21474836 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 1 RENAULT_LAUNCH_CTRL_OCCURRENCE_1

  • Service 22DID 213C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 2 RENAULT_LAUNCH_CTRL_2

  • Service 22DID 2DE1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-21474836 to 21474836 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 2 RENAULT_LAUNCH_CTRL_OCCURRENCE_2

  • Service 22DID 213C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 3 RENAULT_LAUNCH_CTRL_3

  • Service 22DID 2DE1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 64 to 95 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-21474836 to 21474836 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 3 RENAULT_LAUNCH_CTRL_OCCURRENCE_3

  • Service 22DID 213C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 4 RENAULT_LAUNCH_CTRL_4

  • Service 22DID 2DE1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-21474836 to 21474836 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 4 RENAULT_LAUNCH_CTRL_OCCURRENCE_4

  • Service 22DID 213C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 5 RENAULT_LAUNCH_CTRL_OCCURRENCE_5

  • Service 22DID 213C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 5, raw count RENAULT_LAUNCH_CTRL_5

  • Service 22DID 2DE1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2015 to 2026.

Launch control - occurrence 6 RENAULT_LAUNCH_CTRL_6

  • Service 22DID 2DE1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 160 to 191 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-21474836 to 21474836 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 6 RENAULT_LAUNCH_CTRL_OCCURRENCE_6

  • Service 22DID 213C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 160 to 191 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 7 RENAULT_LAUNCH_CTRL_7

  • Service 22DID 2DE1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 192 to 223 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-21474836 to 21474836 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 7 RENAULT_LAUNCH_CTRL_OCCURRENCE_7

  • Service 22DID 213C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 192 to 223 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 8 RENAULT_LAUNCH_CTRL_8

  • Service 22DID 2DE1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 224 to 255 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-21474836 to 21474836 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 8 RENAULT_LAUNCH_CTRL_OCCURRENCE_8

  • Service 22DID 213C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 224 to 255 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 9 RENAULT_LAUNCH_CTRL_9

  • Service 22DID 2DE1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 256 to 287 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-21474836 to 21474836 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 9 RENAULT_LAUNCH_CTRL_OCCURRENCE_9

  • Service 22DID 213C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 256 to 287 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 10 RENAULT_LAUNCH_CTRL_10

  • Service 22DID 2DE1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 288 to 319 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-21474836 to 21474836 km
Unit
km

In testing for 2015 to 2026.

Launch control - occurrence 10 RENAULT_LAUNCH_CTRL_OCCURRENCE_10

  • Service 22DID 213C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 288 to 319 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2015 to 2026.

Launch control counter RENAULT_LAUNCH_CTRL_CNT

  • Service 21PID 42
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Leakage, current RENAULT_LEAKAGE_CURRENT

  • Service 22DID 5064
  • Module792
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Learning limp home 1 throttle position RENAULT_LEARNING_LIMP_HOME_1

  • Service 22DID FDF4
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000152588
Range
-5 to 4.99 V
Unit
V

In testing for 2015 to 2026.

Learning limp home 2 throttle position RENAULT_LEARNING_LIMP_HOME_2

  • Service 22DID FDF5
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000152588
Range
-5 to 4.99 V
Unit
V

In testing for 2015 to 2026.

Left indicator request RENAULT_LEFT_INDICATOR_REQ

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Left position of the secondary fork RENAULT_LEFT_POS_SECONDARY

  • Service 22DID 2B41
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Level of assistance available RENAULT_LEVEL_ASSISTANCE

  • Service 21PID 01
  • Module742
  • Every5 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Line pressure regulation of sol valve, current RENAULT_LINE_P_REGUL_SOL_VLV

  • Service 22DID 1212
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 A
Unit
A

In testing for 2015 to 2026.

Load signal RENAULT_LOAD_SIG

  • Service 22DID 1302
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Locking solenoid valve control time RENAULT_LOCKING_SOLENOID_VLV

  • Service 21PID A3
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val500
Range
0 to 131 ms
Unit
ms

In testing for 2015 to 2026.

Locking supply diagnostic outside limits RENAULT_LOCKING_SUP_DIAG

  • Service 21PID 02
  • Module752 → 772
  • Every250 ms
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Locking supply diagnostic outside limits RENAULT_LOCKING_SUP_DIAG_OUTSIDE

  • Service 21PID 03
  • Module752 → 772
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Low position of the left primary actuator RENAULT_LOW_POS_LEFT_PRIMARY_ACTUATOR

  • Service 22DID 2B3E
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Low position of the left primary fork RENAULT_LOW_POS_LEFT_PRIMARY

  • Service 22DID 2B3C
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Low position of the right primary actuator RENAULT_LOW_POS_RIGHT_PRIMARY

  • Service 22DID 2B3F
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Low position of the right primary fork RENAULT_LOW_POS_RIGHT

  • Service 22DID 2B3D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Low power supply RENAULT_LOW_POWER_SUP

  • Service 22DID 232D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Low pressure EGR air temperature RENAULT_LOW_P_EGR_AIR_T

  • Service 22DID 28C9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Low pressure EGR position reference value RENAULT_LOW_P_EGR_POS

  • Service 22DID 257C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Low pressure EGR valve first offset RENAULT_LOW_P_EGR_VLV_FIRST

  • Service 22DID 2563
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Low pressure EGR valve programming RENAULT_LOW_P_EGR_VLV

  • Service 22DID 2566
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Low pressure pump fault type RENAULT_LOW_P_PMP_FAULT_TYPE

  • Service 22DID 288A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Lpli pump PWM signal RENAULT_LPLI_PMP_PWM_SIG

  • Service 22DID 2887
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2015 to 2026.

Lpli pump PWM signal RENAULT_LPLI_PMP_PWM_SIG_7E0

  • Service 22DID FDC3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.00152588
Range
0 to 99.99 %
Unit
%

In testing for 2015 to 2026.

Main injection flow RENAULT_MAIN_INJ_FLOW

  • Service 22DID 2809
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 2015 to 2026.

Maintenance autonomy interval in days RENAULT_MAINTENANCE_AUTONOMY_INTERVAL_DAYS

  • Service 22DID 020C
  • Module743 → 763
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Maintenance autonomy interval in km RENAULT_MAINTENANCE_AUTONOMY

  • Service 22DID 020B
  • Module743 → 763
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×64103
Range
0 to 40720 mi
Unit
mi

In testing for 2015 to 2026.

Maintenance autonomy/current value days RENAULT_MAINTENANCE_AUTONOMY_CURRENT_DAYS

  • Service 22DID 020E
  • Module743 → 763
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Maintenance autonomy/current value in km RENAULT_MAINTENANCE_AUTONOMY_CURRENT_KM

  • Service 22DID 020D
  • Module743 → 763
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×64103
Range
0 to 40720 mi
Unit
mi

In testing for 2015 to 2026.

Maintenance mode RENAULT_MAINTENANCE_MODE

  • Service 22DID 0115
  • ModuleDADA → DA
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Maintenance mode RENAULT_MAINTENANCE_MODE_DADA

  • Service 22DID 2ABA
  • ModuleDADA → DA
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Manifold air temperature RENAULT_MANIFOLD_AIR_T

  • Service 22DID 243F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Manifold pressure RENAULT_MANIFOLD_P

  • Service 22DID 240B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kPa
Unit
kPa

In testing for 2015 to 2026.

Manifold pressure RENAULT_MANIFOLD_P_7E0

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val×376400+10.3
Range
0 to 389 kPa
Unit
kPa

In testing for 2015 to 2026.

Manifold pressure RENAULT_MANIFOLD_P_7E0_2

  • Service 22DID 24E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Manifold pressure RENAULT_MANIFOLD_P_DADA

  • Service 22DID 112A
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2015 to 2026.

Manifold pressure RENAULT_MANIFOLD_P_DADA_2

  • Service 22DID 140E
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2015 to 2026.

Manifold pressure sensor voltage RENAULT_MANIFOLD_P_SNS_V

  • Service 22DID FD81
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.9997 V
Unit
V

In testing for 2015 to 2026.

Manifold pressure, linearized RENAULT_MANIFOLD_P_LIN

  • Service 22DID 24D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Manual mode RENAULT_MANUAL_MODE

  • Service 22DID 130E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Manual or assisted parking brake RENAULT_MANUAL_OR_ASSISTED

  • Service 22DID 222B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Manual or assisted parking brake RENAULT_MANUAL_OR_ASSISTED_2

  • Service 22DID 222B
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Mass air flow RENAULT_MAF_7E0

  • Service 22DID 2422
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276
Unit
Number

In testing for 2015 to 2026.

Master cylinder pressure RENAULT_MASTER_CYL_P

  • Service 22DID 4B0E
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2015 to 2026.

Mastervac pressure RENAULT_MASTERVAC_P

  • Service 22DID 2890
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Mastervac pressure RENAULT_MASTERVAC_P_V3

  • Service 22DID 20AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750
Unit
Raw value

In testing for 2015 to 2026.

Maximum adaptive richness value RENAULT_MAX_ADAPTIVE

  • Service 22DID 288E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32640
Range
-32640 to 32895
Unit
Number

In testing for 2015 to 2026.

Maximum engine torque allowed RENAULT_MAX_ENG_TQ_ALLOWED

  • Service 22DID 0061
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Maximum ethanol content RENAULT_MAX_ETHANOL_CONTENT

  • Service 22DID FD18
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val128
Range
0 to 1.99
Unit
Number

In testing for 2015 to 2026.

Measured air flow RENAULT_MAF

Pelican can show this parameter as the mass air flow.

  • Service 22DID 24F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 g/s
Unit
g/s

In testing for 2015 to 2026.

Measured air flow RENAULT_MEAS_AIR_FLOW

  • Service 22DID 24F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2015 to 2026.

Measured air flow RENAULT_MEAS_AIR_FLOW_V2

  • Service 22DID 1209
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 g/s
Unit
g/s

In testing for 2015 to 2026.

Measured throttle position RENAULT_MEAS_THROTTLE_POS

  • Service 22DID 242F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2015 to 2026.

Measured throttle position RENAULT_MEAS_THROTTLE_POS_7E0

  • Service 22DID FDD5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000152588
Range
-5 to 4.99 V
Unit
V

In testing for 2015 to 2026.

Measured throttle position RENAULT_MEAS_THROTTLE_POS_V2

  • Service 22DID FD6E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Measured throttle potentiometer position RENAULT_MEAS_THROTTLE

  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1651
Range
0 to 80 °
Unit
°

In testing for 2015 to 2026.

Mileage since last appearance of fault RENAULT_MILEAGE_SINCE

  • Service 22DID F0D0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Minimum adaptive richness value RENAULT_MIN_ADAPTIVE

  • Service 22DID 288D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32640
Range
-32640 to 32895
Unit
Number

In testing for 2015 to 2026.

Misfire counter, total RENAULT_MISFIRE_CNT

  • Service 22DID 2874
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Modulating solenoid valve control time RENAULT_MODULATING_SOLENOID

  • Service 21PID A3
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val500
Range
0 to 131 ms
Unit
ms

In testing for 2015 to 2026.

Module temperature number 1 RENAULT_MODULE_T_NUMBER_1

  • Service 22DID 9131
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Module temperature number 2 RENAULT_MODULE_T_NUMBER_2

  • Service 22DID 9132
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Module temperature number 3 RENAULT_MODULE_T_NUMBER_3

  • Service 22DID 9133
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Module temperature number 4 RENAULT_MODULE_T_NUMBER_4

  • Service 22DID 9134
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Module temperature number 5 RENAULT_MODULE_T_NUMBER_5

  • Service 22DID 9135
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Module temperature number 6 RENAULT_MODULE_T_NUMBER_6

  • Service 22DID 9136
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Module temperature number 7 RENAULT_MODULE_T_NUMBER_7

  • Service 22DID 9137
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Module temperature number 8 RENAULT_MODULE_T_NUMBER_8

  • Service 22DID 9138
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Module temperature number 9 RENAULT_MODULE_T_NUMBER_9

  • Service 22DID 9139
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Module temperature number 10 RENAULT_MODULE_T_NUMBER_10

  • Service 22DID 913A
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Module temperature number 11 RENAULT_MODULE_T_NUMBER_11

  • Service 22DID 913B
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Module temperature number 12 RENAULT_MODULE_T_NUMBER_12

  • Service 22DID 913C
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2015 to 2026.

Module with, minimum temperature RENAULT_MODULE_MIN_T

  • Service 22DID 9242
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Mot. throttle corrected position setting RENAULT_MOT_THROTTLE

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val×25256
Range
0 to 6399 %
Unit
%

In testing for 2015 to 2026.

Mot. throttle high stop programmed value RENAULT_MOT_THROTTLE_HIGH

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×4001023
Range
0 to 99.7 %
Unit
%

In testing for 2015 to 2026.

Mot. throttle low stop programmed value RENAULT_MOT_THROTTLE_LOW

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×4001023
Range
0 to 99.7 %
Unit
%

In testing for 2015 to 2026.

Mot. throttle low stop programmed value RENAULT_MOT_THROTTLE_LOW_V2

  • Service 22DID 2457
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2015 to 2026.

Mot. throttle position corrected value RENAULT_MOT_THROTTLE_POS

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Motor status RENAULT_MOTOR

  • Service 22DID 2010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Motor status RENAULT_MOTOR_STS_TC

  • Service 22DID 300D
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Motor-driven fan unit request RENAULT_MOTOR_DRIVEN_FAN

  • Service 22DID 2927
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Motor-driven fan unit request RENAULT_MOTOR_DRIVEN_FAN_UNIT_REQ

  • Service 22DID 91C9
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2015 to 2026.

Motor, ECM RENAULT_ECM_MOTOR

  • Service 21PID C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 84 to 85 of the reply, 2 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2015 to 2026.

Motorised throttle position reference RENAULT_MOTORISED_THROTTLE_V2

  • Service 22DID 2414
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2015 to 2026.

Motorized throttle RENAULT_MOTORISED_THROTTLE_2_2

  • Service 22DID 1302
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Motorized throttle duty cycle RENAULT_MOTORISED_THROTTLE_OCR

  • Service 22DID 241F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Motorized throttle in defect mode RENAULT_MOTORISED_THROTTLE

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×4001023
Range
0 to 99.7 %
Unit
%

In testing for 2015 to 2026.

Motorized throttle in defect mode RENAULT_MOTORISED_THROTTLE_DEFECT

  • Service 22DID FDEE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Motorized throttle in defect mode track 1 RENAULT_MOTORISED_THROTTLE_DEFECT_1

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val×201023
Range
0 to 4.98 V
Unit
V

In testing for 2015 to 2026.

Motorized throttle in defect mode track 2 RENAULT_MOTORISED_THROTTLE_DEFECT_2

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
val×201023
Range
0 to 4.98 V
Unit
V

In testing for 2015 to 2026.

Motorized throttle track 1 lower stop RENAULT_MOTORISED_THROTTLE_TRACK_1

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×201023
Range
0 to 4.98 V
Unit
V

In testing for 2015 to 2026.

Motorized throttle track 1 upper stop RENAULT_MOTORISED_THROTTLE_1

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×201023
Range
0 to 4.98 V
Unit
V

In testing for 2015 to 2026.

Motorized throttle track 2 lower stop RENAULT_MOTORISED_THROTTLE_TRACK_2

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×201023
Range
0 to 4.98 V
Unit
V

In testing for 2015 to 2026.

Motorized throttle track 2 lower stop RENAULT_MOTORISED_THROTTLE_TRACK_2_LO_STOP

  • Service 22DID FDF2
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000152588
Range
-5 to 4.99 V
Unit
V

In testing for 2015 to 2026.

Motorized throttle track 2 upper stop RENAULT_MOTORISED_THROTTLE_2

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2015 to 2026.

No. of cycles since fault disappeared RENAULT_NO_CYCLES_SINCE

  • Service 22DID F0D1
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Number of abnormal cc/sl transitions RENAULT_NUM_ABNORMAL_CC_SL

  • Service 22DID 207E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Number of abnormal cc/sl transitions RENAULT_NUM_ABNORMAL_CC_SL_2

  • Service 22DID 207E
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Number of failed regenerations RENAULT_NUM_FAILED_REGEN

  • Service 22DID 25A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Number of memory zones erased RENAULT_NUM_MEMORY_ZONES

  • Service 21PID 02
  • Module752 → 772
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Number of occurrences of fault RENAULT_NUM_OCCURRENCES

  • Service 22DID F0D1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Number of regeneration failure RENAULT_NUM_REGEN_FAILURE

  • Service 22DID 2485
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Number of rotation of engine RENAULT_NUM_ROT_ENG

  • Service 21PID 6A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 39 of the reply, 32 bits.

Formula
val1000000
Range
0 to 4294
Unit
Number

In testing for 2015 to 2026.

Number of rotation of engine RENAULT_NUM_ROT_ENG_7E0

  • Service 21PID 6A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000000
Range
0 to 4294
Unit
Number

In testing for 2015 to 2026.

Number of rotation of engine RENAULT_NUM_ROT_ENG_V2

  • Service 22DID 210E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val+2147483648
Range
0 to 4294967295
Unit
Raw value

In testing for 2015 to 2026.

Number of starting 1 RENAULT_NUM_STARTING_1

  • Service 22DID 216B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2015 to 2026.

Number of starting 2 RENAULT_NUM_STARTING_2

  • Service 22DID 216A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2015 to 2026.

Number of starting 3 RENAULT_NUM_STARTING_3

  • Service 22DID 2169
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2015 to 2026.

Number of starting 4 RENAULT_NUM_STARTING_4

  • Service 22DID 2168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2015 to 2026.

Number of starts since successful regen RENAULT_NUM_STARTS_SINCE

  • Service 22DID 30D9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Odometer fault LED illuminated RENAULT_MILEOMETER_FAULT_LED

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val×71110000
Range
0 to 4659 km
Unit
km

In testing for 2015 to 2026.

Offset memorized on the selection RENAULT_OFFSET_MEMORISED_ON

  • Service 22DID 2B45
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Oil change frequency in days RENAULT_OIL_CHANGE_FREQUENCY

  • Service 22DID 0202
  • Module743 → 763
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Oil change history 1 RENAULT_OIL_CHANGE_HISTORY_1

  • Service 22DID 12C1
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2015 to 2026.

Oil change history 2 RENAULT_OIL_CHANGE_HISTORY_2

  • Service 22DID 12C2
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2015 to 2026.

Oil change history 3 RENAULT_OIL_CHANGE_HISTORY_3

  • Service 22DID 12C3
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2015 to 2026.

Oil change interval in km RENAULT_OIL_CHANGE_INTERVAL

  • Service 21PID 11
  • Module743 → 763
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×1000
Range
0 to 255000 km
Unit
km

In testing for 2015 to 2026.

Oil change interval in km RENAULT_OIL_CHANGE_INTERVAL_KM

  • Service 22DID 0201
  • Module743 → 763
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×64103
Range
0 to 40720 mi
Unit
mi

In testing for 2015 to 2026.

Oil change interval in months RENAULT_OIL_CHANGE_INTERVAL_MONTHS

  • Service 21PID 11
  • Module743 → 763
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Oil dilution information RENAULT_OIL_DILUTION

  • Service 22DID 2489
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val655
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Oil oxidation information RENAULT_OIL_OXIDATION

  • Service 21PID 6A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Oil pressure RENAULT_OIL_P

  • Service 21PID A2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 bar
Unit
bar

In testing for 2015 to 2026.

Oil pressure RENAULT_OIL_P_2

  • Service 22DID 1278
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2015 to 2026.

Oil pressure RENAULT_OIL_P_7E0

  • Service 22DID 25B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2015 to 2026.

Oil pressure reference value RENAULT_OIL_P_REFERENCE

  • Service 22DID FD3D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Oil pressure sensor RENAULT_OIL_P_SENS_7E0

  • Service 22DID FDCC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000152588
Range
0 to 9.99 V
Unit
V

In testing for 2015 to 2026.

Oil pressure sensor information RENAULT_OIL_P_SENS

  • Service 21PID 10
  • Module74D → 76D
  • Every5 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Oil pressure switch RENAULT_OIL_P_SWITCH

  • Service 21PID 10
  • Module743 → 763
  • Every5 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Oil pressure switch RENAULT_OIL_P_SWITCH_743

  • Service 22DID 2008
  • Module743 → 763
  • Every1 s
  • Testing

Bits 6 to 7 of the reply, 2 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2015 to 2026.

Oil pump return RENAULT_OIL_PMP_RETURN

  • Service 22DID 308D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Oil service interval in days RENAULT_OIL_SERVICE_INTERVAL

  • Service 22DID 0204
  • Module743 → 763
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Oil temperature RENAULT_OIL_T

  • Service 22DID 111F
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2015 to 2026.

Oil vapor heater RENAULT_OIL_VAPOUR_HEATER

  • Service 22DID 20DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Oil wear counter RENAULT_OIL_WEAR_CNT

  • Service 22DID 1503
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647
Unit
Number

In testing for 2015 to 2026.

Operating richness adaptive RENAULT_OP_RICHNESS_ADAPTIVE

  • Service 22DID 2873
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val98304+0.666656
Range
0 to 1.33
Unit
Number

In testing for 2015 to 2026.

Oxygen rate RENAULT_OXYGEN_RATE

  • Service 22DID FE72
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100000
Range
-0.327 to 0.327
Unit
Number

In testing for 2015 to 2026.

P/n position switch RENAULT_P_N_POS_SWITCH

  • Service 22DID 1302
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Park/neutral position RENAULT_PARK_NEUTRAL_POS

  • Service 22DID 20A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Park/neutral position RENAULT_PARK_NEUTRAL_POS_2

  • Service 22DID 29A9
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Particle filter diff. pressure correction RENAULT_PARTICLE_FLT_DIFF_P

  • Service 22DID 24FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767
Unit
Raw value

In testing for 2015 to 2026.

Particle filter injector RCO command RENAULT_PARTICLE_FLT_INJ_RCO

  • Service 22DID 2826
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2015 to 2026.

Particle filter pressure diff RENAULT_PARTICLE_FLT_P_DIFF

  • Service 22DID 2542
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000−3.2768
Range
-6.55 to -0.0002 bar
Unit
bar

In testing for 2015 to 2026.

Particle filter pressure offset RENAULT_PARTICLE_FLT_P

  • Service 22DID 30E2
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×5128+83886080
Range
0 to 167772159
Unit
Number

In testing for 2015 to 2026.

Particle filter pressure offset RENAULT_PARTICLE_FLT_P_V2

  • Service 22DID 24C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767
Unit
Raw value

In testing for 2015 to 2026.

PARTICLE FILTER UPSTREAM temperature. REF VALUE RENAULT_PARTICLE_FLT_UP_T

  • Service 22DID 2432
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Pass comp. heating relay 1 control RENAULT_PASS_COMP_HEATING_1

  • Service 21PID C1
  • Module745 → 765
  • Every5 s
  • Testing

Bit 71 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Pass comp. heating relay 2 control RENAULT_PASS_COMP_HEATING_2

  • Service 21PID C1
  • Module745 → 765
  • Every5 s
  • Testing

Bit 70 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Pass. compartment fan PWM value RENAULT_PASS_COMPARTMENT_FAN

  • Service 21PID 21
  • Module744 → 764
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Passenger air bag locking mode RENAULT_PASSENGER_AIR_BAG_LOCKING

  • Service 21PID 02
  • Module752 → 772
  • Every250 ms
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Passenger air bag locking mode RENAULT_PASSENGER_AIR_BAG_LOCKING_MODE

  • Service 21PID 03
  • Module752 → 772
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Passenger air bag locking type RENAULT_PASSENGER_AIR_BAG

  • Service 21PID 02
  • Module752 → 772
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Passenger air bag status light RENAULT_PASSENGER_AIR_BAG_STAT

  • Service 21PID 03
  • Module752 → 772
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Passenger compartment fan RENAULT_PASSENGER

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 80 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Passenger front air bag circuit 1 RENAULT_PASSENGER_FRONT_AIR_1

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Passenger front air bag circuit 1 RENAULT_PASSENGER_FRONT_AIR_BAG_1

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Passenger front air bag circuit 2 RENAULT_PASSENGER_FRONT_AIR_2

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Passenger front air bag circuit 2 RENAULT_PASSENGER_FRONT_AIR_BAG_2

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Passenger presence detected RENAULT_PASSENGER_PRESENCE

  • Service 21PID 06
  • Module752 → 772
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Passenger presence detected RENAULT_PASSENGER_PRESENCE_DETECTED

  • Service 21PID 03
  • Module752 → 772
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Passenger presence detection sensor RENAULT_PASSENGER_PRESENCE_DETECTION_SENS

  • Service 21PID 09
  • Module752 → 772
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Passenger side rear strap sensor RENAULT_PASSENGER_SIDE_REAR

  • Service 21PID 09
  • Module752 → 772
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Passenger's airbag, s locked RENAULT_PASSENGER_S_AIRBAG_S

  • Service 21PID 03
  • Module752 → 772
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Passenger's lap strap/seat airbag RENAULT_PASSENGER_S_LAP

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Passenger's lap strap/seat airbag RENAULT_PASSENGER_S_LAP_STRAP_SEAT

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Passenger's lateral sensor RENAULT_PASSENGER_S_LATERAL

  • Service 21PID 09
  • Module752 → 772
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Passenger's seat buckle sensor RENAULT_PASSENGER_S_SEAT

  • Service 21PID 09
  • Module752 → 772
  • Every1 s
  • Testing

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Peb fusebox interlock RENAULT_PEB_FUSEBOX

  • Service 22DID 3055
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Peb fusebox interlock RENAULT_PEB_FUSEBOX_INTERLOCK

  • Service 22DID 314E
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Peb input water temperature RENAULT_PEB_INPUT_WATER_T

  • Service 22DID 21DB
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Pedal load RENAULT_PEDAL_LOAD

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The value is signed.

Formula
val×0.01220703
Range
-399 to 399 %
Unit
%

In testing for 2015 to 2026.

Pedal no load programming RENAULT_PEDAL_NO_LOAD

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2015 to 2026.

Pedal position track 1 RENAULT_PEDAL_POS_TRACK_1

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×201023
Range
0 to 4.98 V
Unit
V

In testing for 2015 to 2026.

Pedal position track 2 RENAULT_PEDAL_POS_TRACK_2

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×201023
Range
0 to 4.98 V
Unit
V

In testing for 2015 to 2026.

Phase 2, current RENAULT_PHASE_2_CURRENT

  • Service 22DID 503A
  • Module792
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−200
Range
-200 to 3895 A
Unit
A

In testing for 2015 to 2026.

Phase 3 or neutral, current RENAULT_PHASE_3_OR_NEUTRAL

  • Service 22DID 503B
  • Module792
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−200
Range
-200 to 3895 A
Unit
A

In testing for 2015 to 2026.

Pilot control cyclical ratio RENAULT_PILOT_CTRL_CYCLICAL

  • Service 22DID 3088
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2015 to 2026.

Pilot control cyclical ratio RENAULT_PILOT_CTRL_CYCLICAL_V2

  • Service 22DID 5026
  • Module792
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2015 to 2026.

Pilot injection flow 1 RENAULT_PRE_INJ_FLOW_1

  • Service 22DID FD32
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Pilot injection flow 2 RENAULT_PRE_INJ_FLOW_2

  • Service 22DID FD33
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Position of inlet flap RENAULT_POS_INLET_FLAP

  • Service 21PID A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Post injection flow RENAULT_POST_INJ_FLOW

  • Service 22DID 280D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 2015 to 2026.

Post injection flow 1 RENAULT_POST_INJ_FLOW_1

  • Service 22DID 280E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 2015 to 2026.

Post injection phasing RENAULT_POST_INJ_PHASING

  • Service 22DID 2813
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50−655.36
Range
-655 to 655 °
Unit
°

In testing for 2015 to 2026.

Post-ignition status RENAULT_ECU_POST_IGN

  • Service 22DID 200E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Potentiometer value EGR valve closed RENAULT_POTENTIOMETER_EGR

  • Service 22DID 24CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2015 to 2026.

Power absorbed by the AC compressor RENAULT_POWER_ABSORBED_AC

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100 W
Unit
W

In testing for 2015 to 2026.

Power steering signal RENAULT_POWER_STEER_SIG

  • Service 22DID 1302
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Preheating mode RENAULT_PREHEATING_MODE

  • Service 22DID 219A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 %
Unit
%

In testing for 2015 to 2026.

Preheating relay control RENAULT_PREHEATING_RELAY

  • Service 22DID 201A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Pressure before turbine RENAULT_P_BEFORE_TURBINE

  • Service 22DID 2448
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Pressure in particle filter RENAULT_P_PARTICLE_FLT

  • Service 22DID 2542
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767
Unit
Raw value

In testing for 2015 to 2026.

Pressure sensor offset RENAULT_P_SNS_OFFSET

  • Service 22DID 4B39
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 bar
Unit
bar

In testing for 2015 to 2026.

Pressure sensor programming offset RENAULT_P_SENS_PROGRAMMING

  • Service 22DID 4B39
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5−25.4
Range
-25.4 to 25.6 bar
Unit
bar

In testing for 2015 to 2026.

Pressure upstream of turbine RENAULT_P_UP_TURBINE

  • Service 22DID 2448
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Pressure, LPG RENAULT_LPG_P

  • Service 22DID F423
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2015 to 2026.

Pressure, LPG RENAULT_LPG_P_7E0

  • Service 22DID 20C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Primary claw lower position RENAULT_PRIMARY_CLAW_LO_POS

  • Service 22DID 302B
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Primary claw position set point RENAULT_PRIMARY_CLAW_POS

  • Service 22DID 2B70
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.8 to 12.7 mm
Unit
mm

In testing for 2015 to 2026.

Primary claw upper position RENAULT_PRIMARY_CLAW_HI_POS

  • Service 22DID 302C
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Primary hydraulic pressure RENAULT_PRIMARY_HYDRAULIC_P

  • Service 22DID 1128
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 bar
Unit
bar

In testing for 2015 to 2026.

Primary oil press. regulation sv, current RENAULT_PRIMARY_OIL_PRESS

  • Service 22DID 1213
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 A
Unit
A

In testing for 2015 to 2026.

Programming throttle limits RENAULT_PROGRAMMING_THROTTLE

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 77 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Programming throttle limits RENAULT_PROGRAMMING_THROTTLE_2

  • Service 22DID 1305
  • ModuleDADA → DA
  • Every3600 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Programming throttle limits RENAULT_PROGRAMMING_THROTTLE_LIMITS

  • Service 22DID FDFE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Proportional richness sensor RENAULT_PROPORTIONAL

  • Service 22DID 251E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

In testing for 2015 to 2026.

Pull compensation RENAULT_PULL_COMPENSATION

  • Service 21PID 01
  • Module742
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.8 to 12.7 N·m
Unit
N·m

In testing for 2015 to 2026.

Pulling correction program RENAULT_PULLING_CORR_PROGRAM

  • Service 21PID 03
  • Module742 → 762
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Pulse lever down switch RENAULT_LEVER_DOWN_SWITCH

  • Service 22DID 23B3
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Pulse lever down switch RENAULT_LEVER_DOWN_SWITCH_V2

  • Service 22DID 2D4E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Pulse lever up switch RENAULT_LEVER_UP_SWITCH

  • Service 22DID 23B2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Pulse lever up switch RENAULT_LEVER_UP_SWITCH_V2

  • Service 22DID 2D4D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Purge volume control valve RENAULT_PURGE_VOLUME_CTRL

  • Service 22DID 1110
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2015 to 2026.

Rail pressure RENAULT_RAIL_P

  • Service 22DID 2801
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 bar
Unit
bar

In testing for 2015 to 2026.

Rail pressure RENAULT_RAIL_P_7E0

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 bar
Unit
bar

In testing for 2015 to 2026.

Rail pressure loop variation RENAULT_RAIL_P_LOOP

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 bar
Unit
bar

In testing for 2015 to 2026.

Rail pressure regulator, current RENAULT_RAIL_P_REGULATOR_CURRENT

  • Service 21PID A6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 2015 to 2026.

Rail pressure regulator, current ref.value RENAULT_RAIL_P_REGULATOR

  • Service 21PID A6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 2015 to 2026.

Rail pressure setting RENAULT_RAIL_P_SETTING

  • Service 22DID 2802
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 bar
Unit
bar

In testing for 2015 to 2026.

Rail pressure setting RENAULT_RAIL_P_SETTING_7E0

  • Service 21PID A6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 bar
Unit
bar

In testing for 2015 to 2026.

Rapid torque reference value RENAULT_RAPID_TQ_REFERENCE

  • Service 22DID 112B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2015 to 2026.

Raw boost pressure from sensor RENAULT_RAW_BOOST_P_SENS

  • Service 22DID 20C4
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Raw leakage direct, current, DC RENAULT_RAW_LEAKAGE_DIRECT

  • Service 22DID 5057
  • Module792
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−2048
Range
-2048 to 2047
Unit
Number

In testing for 2015 to 2026.

Raw leakage high frequency, current RENAULT_RAW_LEAKAGE_HIGH

  • Service 22DID 5059
  • Module792
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−2048
Range
-2048 to 2047
Unit
Number

In testing for 2015 to 2026.

Raw leakage low frequency, current RENAULT_RAW_LEAKAGE_LOW

  • Service 22DID 505A
  • Module792
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−2048
Range
-2048 to 2047
Unit
Number

In testing for 2015 to 2026.

Raw leakage very high frequency, current RENAULT_RAW_LEAKAGE_VERY

  • Service 22DID 5058
  • Module792
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−2048
Range
-2048 to 2047
Unit
Number

In testing for 2015 to 2026.

Rear fog lights request RENAULT_REAR_FOG_LIGHTS_REQ

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 78 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Rear inertia reels RENAULT_REAR_INERTIA_REELS

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Rear inertia reels RENAULT_REAR_INERTIA_REELS_752

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Rear screen wiper parked position RENAULT_REAR_SCREEN_WIPER

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Rear thorax side air bag. driver side RENAULT_REAR_THORAX_SIDE_AIR_BAG

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Rear thorax side air bag. driver side RENAULT_REAR_THORAX_SIDE_AIR_BAG_DRIVER

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Rear thorax side air bag. passenger side RENAULT_REAR_THORAX_SIDE_AIR

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Rear thorax side air bag. passenger side RENAULT_REAR_THORAX_SIDE_AIR_BAG_PASSENGER

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Rear wiper request RENAULT_REAR_WIPER_REQ

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 51 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Recirculation motor set point RENAULT_RECIRCULATION_MOTOR

  • Service 21PID 27
  • Module744 → 764
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Recycling flap position RENAULT_RECYCLING_FLAP_POS

  • Service 21PID 27
  • Module744 → 764
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Reference pressure RENAULT_REFERENCE_P

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2015 to 2026.

Refrigerant circuit 2-way solenoid valve RENAULT_REFRIGERANT_CIRCUIT_2

  • Service 21PID 68
  • Module744 → 764
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Refrigerant circuit 3-way solenoid valve RENAULT_REFRIGERANT_CIRCUIT_3

  • Service 21PID 68
  • Module744 → 764
  • Every1 s
  • Testing

Bits 36 to 39 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2015 to 2026.

Refrigerant inlet temperature RENAULT_REFRIGERANT_INLET_T

  • Service 21PID 67
  • Module744 → 764
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2015 to 2026.

Refrigerant outlet temperature RENAULT_REFRIGERANT_OUTLET_T

  • Service 21PID 67
  • Module744 → 764
  • Every5 s
  • Testing

Bits 36 to 45 of the reply, 10 bits.

Formula
val2−40
Range
-40 to 471 °C
Unit
°C

In testing for 2015 to 2026.

Refrigerant pressure RENAULT_REFRIGERANT_P

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val
Range
0 to 255 bar
Unit
bar

In testing for 2015 to 2026.

Refrigerant pressure RENAULT_REFRIGERANT_P_744

  • Service 21PID 43
  • Module744 → 764
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535 bar
Unit
bar

In testing for 2015 to 2026.

Refrigerant pressure RENAULT_REFRIGERANT_P_7E0

  • Service 21PID A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val500
Range
-65.53 to 65.53 bar
Unit
bar

In testing for 2015 to 2026.

Refrigerant pressure RENAULT_REFRIGERANT_P_V2

  • Service 22DID 222A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 bar
Unit
bar

In testing for 2015 to 2026.

Refrigerant pressure RENAULT_REFRIGERANT_P_V3

  • Service 21PID 43
  • Module744 → 764
  • Every5 s
  • Testing

Bits 118 to 126 of the reply, 9 bits.

Formula
val10
Range
0 to 51.1 bar
Unit
bar

In testing for 2015 to 2026.

Regeneration authorisation RENAULT_REGEN_AUTHORISATION

  • Service 22DID 2166
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Regeneration command RENAULT_REGEN_COMMAND

  • Service 22DID 11A3
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Regeneration command RENAULT_REGEN_COMMAND_V2

  • Service 22DID 246D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Request to injection or power switching unit, body control RENAULT_UCH_REQ_INJ_OR_UPC

  • Service 21PID 10
  • Module74D → 76D
  • Every5 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Requested engine torque RENAULT_REQ_ENG_TQ

  • Service 22DID 0052
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095
Unit
Number

In testing for 2015 to 2026.

Resistant engine torque transmitted on CAN RENAULT_RESISTANT_ENG_TQ_ON

  • Service 21PID A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2015 to 2026.

Richness adaptive value RENAULT_RICHNESS_ADAPTIVE

  • Service 22DID 287C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Richness correction RENAULT_RICHNESS_CORR

  • Service 22DID 2850
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val98304+0.666656
Range
0 to 1.33 %
Unit
%

In testing for 2015 to 2026.

Richness correction RENAULT_RICHNESS_CORR_7E0

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val×0.001526
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Richness correction RENAULT_RICHNESS_CORR_V2

  • Service 22DID 284E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Richness correction value RENAULT_RICHNESS_CORR_7E0_2

  • Service 22DID 2872
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2015 to 2026.

Richness correction, operating RENAULT_RICHNESS_CORR_OP

  • Service 22DID 2850
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2015 to 2026.

Richness regulation RENAULT_RICHNESS_REGULATION_7E0

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 72 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Richness regulation factor. bank 1 RENAULT_RICHNESS_REGULATION_1

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val98304+0.000007
Range
0 to 0.666
Unit
Number

In testing for 2015 to 2026.

Richness regulation gain RENAULT_RICHNESS_REG_GAIN

  • Service 22DID 2851
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Richness regulation offset RENAULT_RICHNESS_REG_OFFSET

  • Service 22DID 2852
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 ms
Unit
ms

In testing for 2015 to 2026.

Richness regulation offset RENAULT_RICHNESS_REGULATION_OFFSET

  • Service 22DID 20CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Richness regulation programming gain RENAULT_RICHNESS_REGULATION_PROGRAMMING

  • Service 21PID A9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Richness regulation programming gain RENAULT_RICHNESS_REGULATION_PROGRAMMING_V2

  • Service 22DID 20D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val98304+0.666667
Range
0 to 1.33
Unit
Number

In testing for 2015 to 2026.

Richness regulation programming offset RENAULT_RICHNESS_REGULATION

  • Service 21PID A9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Richness regulation programming offset RENAULT_RICHNESS_REGULATION_PROGRAMMING_OFFSET

  • Service 22DID 20CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Richness regulation programming offset RENAULT_RICHNESS_REGULATION_V2

  • Service 22DID 20D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000030518−0.1
Range
-0.1 to 0.0999 ms
Unit
ms

In testing for 2015 to 2026.

Richness, adaptive operating RENAULT_RICHNESS_ADAPT

  • Service 22DID 2873
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Right indicator request RENAULT_RIGHT_INDICATOR_REQ

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Right position of the secondary fork RENAULT_RIGHT_POS_SECONDARY

  • Service 22DID 2B42
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Rough particle filter relative pressure RENAULT_ROUGH_PARTICLE_FLT_P

  • Service 22DID 24E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767
Unit
Raw value

In testing for 2015 to 2026.

Rough pedal position RENAULT_ROUGH_PEDAL_POS

  • Service 21PID A2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2015 to 2026.

Rough pedal position RENAULT_ROUGH_PEDAL_POS_7E1

  • Service 22DID 20FB
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2015 to 2026.

Rough turbocharging pressure RENAULT_ROUGH_TURBOCHARGING_P

  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550
Unit
Raw value

In testing for 2015 to 2026.

S&s inhibition, braking pressure RENAULT_S_S_INHIBITION_P

  • Service 22DID 3078
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

S&s inhibition, energy management RENAULT_S_S_INHIBITION

  • Service 22DID 3078
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

S&s inhibition, master vac RENAULT_S_S_INHIBITION_MASTER_VAC

  • Service 22DID 3078
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary actuator left position RENAULT_SECONDARY_ACTUATOR

  • Service 22DID 2B43
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Secondary actuator right position RENAULT_SECONDARY_ACTUATOR_RIGHT

  • Service 22DID 2B44
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Secondary battery management system no. 1 RENAULT_SECONDARY_BMS_NO_1

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary battery management system no. 2 RENAULT_SECONDARY_BMS_NO_2

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary battery management system no. 3 RENAULT_SECONDARY_BMS_NO_3

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary battery management system no. 4 RENAULT_SECONDARY_BMS_NO_4

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary battery management system no. 5 RENAULT_SECONDARY_BMS_NO_5

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary battery management system no. 6 RENAULT_SECONDARY_BMS_NO_6

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary battery management system no. 7 RENAULT_SECONDARY_BMS_NO_7

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary battery management system no. 8 RENAULT_SECONDARY_BMS_NO_8

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary battery management system no. 9 RENAULT_SECONDARY_BMS_NO_9

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary battery management system no. 10 RENAULT_SECONDARY_BMS_NO_10

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary battery management system no. 11 RENAULT_SECONDARY_BMS_NO_11

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary battery management system no. 12 RENAULT_SECONDARY_BMS_NO_12

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Secondary claw position RENAULT_SECONDARY_CLAW_POS

  • Service 22DID 302D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Secondary claw position set point RENAULT_SECONDARY_CLAW_POS_SETPOINT

  • Service 22DID 2B71
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.8 to 12.7 mm
Unit
mm

In testing for 2015 to 2026.

Secondary hydraulic pressure RENAULT_SECONDARY_HYDRAULIC_P

  • Service 22DID 1120
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 bar
Unit
bar

In testing for 2015 to 2026.

Selection position RENAULT_SELECTION_POS

  • Service 21PID A6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 %
Unit
%

In testing for 2015 to 2026.

Selection position RENAULT_SELECTION_POS_V2

  • Service 22DID 2D0A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511
Unit
Number

In testing for 2015 to 2026.

Selector position RENAULT_SELECTOR_POS

  • Service 22DID 302A
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Selector position set point RENAULT_SELECTOR_POS_SETPOINT

  • Service 22DID 2B72
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Sensor diagnostic request RENAULT_SENS_DIAGNOSTIC_REQ

  • Service 22DID 25D6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Sensor heating delay, upstream, O2 RENAULT_O2_UP_HEAT_DELAY

  • Service 22DID 24C4
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Sensor heating resistance, downstream, O2 RENAULT_O2_DN_HEAT_R

  • Service 22DID 244C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 Ω
Unit
Ω

In testing for 2015 to 2026.

Sensor heating resistance, upstream, O2 RENAULT_O2_UP_HEAT_R

  • Service 22DID 244B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 Ω
Unit
Ω

In testing for 2015 to 2026.

Sensor supply circuit RENAULT_SENS_SUP_CIRCUIT

  • Service 22DID FDA7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.99 V
Unit
V

In testing for 2015 to 2026.

Sensor voltage, downstream, O2 RENAULT_O2_DN_V

  • Service 22DID 244A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Sensor voltage, upstream, O2 RENAULT_O2_UP_V

  • Service 22DID 2449
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2015 to 2026.

Set, current absorbed by the motor RENAULT_SET_CURRENT_ABSORBED

  • Service 21PID 01
  • Module742
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 A
Unit
A

In testing for 2015 to 2026.

Sharp decel. without brake depressed RENAULT_SHARP_DECEL_WITHOUT

  • Service 22DID 204F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Sharp decel. without brake depressed RENAULT_SHARP_DECEL_WITHOUT_V2

  • Service 22DID 204F
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Sl inhibited by evc RENAULT_SL_INHIBITED_EVC

  • Service 22DID 204E
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Sl inhibited by injection RENAULT_SL_INHIBITED_INJ

  • Service 22DID 204E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Slow adaptative term of the wastegate control RENAULT_SLOW_ADAPTATIVE_TERM

  • Service 22DID 24C3
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.001525902−50
Range
-50 to 49.99 %
Unit
%

In testing for 2015 to 2026.

Slow torque reference value RENAULT_SLOW_TQ_REFERENCE

  • Service 22DID 112C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2015 to 2026.

Software version, f195 RENAULT_SOFTWARE_VERSION

  • Service 22DID F195
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Soot in the particle filter RENAULT_SOOT_PARTICLE_FLT

  • Service 22DID 242C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 g
Unit
g

In testing for 2015 to 2026.

Source of action before next-last action RENAULT_SOURCE_ACTION_BEFORE

  • Service 21PID 13
  • Module745 → 765
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Source of next-last door action RENAULT_SOURCE_NEXT_LAST

  • Service 21PID 13
  • Module745 → 765
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Stability control ON/OFF BUTTON RENAULT_STABILITY_CTRL_ON_OFF

  • Service 22DID 4B58
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Standard pedal position RENAULT_STANDARD_PEDAL_POS

  • Service 21PID A2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2015 to 2026.

Starter button RENAULT_STARTER_BUTTON

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Starter wear counter RENAULT_STARTER_WEAR_CNT

  • Service 22DID 22AA
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2015 to 2026.

Starter wear counter RENAULT_STARTER_WEAR_CNT_2

  • Service 22DID 22AA
  • ModuleDADA → DA
  • Every3600 s
  • Testing

Bits 40 to 63 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2015 to 2026.

Starting RENAULT_STARTING

  • Service 21PID C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 77 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Starting RENAULT_STARTING_2

  • Service 22DID 1302
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Starting RENAULT_STARTING_7E0

  • Service 22DID 2048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

State of health cell 1 RENAULT_SOH_CELL_1

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 255 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 2 RENAULT_SOH_CELL_2

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 254 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 3 RENAULT_SOH_CELL_3

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 253 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 4 RENAULT_SOH_CELL_4

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 252 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 5 RENAULT_SOH_CELL_5

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 251 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 6 RENAULT_SOH_CELL_6

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 250 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 7 RENAULT_SOH_CELL_7

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 249 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 8 RENAULT_SOH_CELL_8

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 248 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 9 RENAULT_SOH_CELL_9

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 247 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 10 RENAULT_SOH_CELL_10

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 246 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 11 RENAULT_SOH_CELL_11

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 245 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 12 RENAULT_SOH_CELL_12

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 244 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 13 RENAULT_SOH_CELL_13

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 243 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 14 RENAULT_SOH_CELL_14

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 242 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 15 RENAULT_SOH_CELL_15

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 241 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 16 RENAULT_SOH_CELL_16

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 240 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 17 RENAULT_SOH_CELL_17

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 239 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 18 RENAULT_SOH_CELL_18

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 238 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 19 RENAULT_SOH_CELL_19

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 237 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 20 RENAULT_SOH_CELL_20

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 236 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 21 RENAULT_SOH_CELL_21

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 235 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 22 RENAULT_SOH_CELL_22

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 234 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 23 RENAULT_SOH_CELL_23

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 233 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 24 RENAULT_SOH_CELL_24

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 232 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 25 RENAULT_SOH_CELL_25

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 231 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 26 RENAULT_SOH_CELL_26

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 230 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 27 RENAULT_SOH_CELL_27

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 229 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 28 RENAULT_SOH_CELL_28

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 228 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 29 RENAULT_SOH_CELL_29

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 227 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 30 RENAULT_SOH_CELL_30

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 226 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 31 RENAULT_SOH_CELL_31

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 225 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 32 RENAULT_SOH_CELL_32

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 224 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 33 RENAULT_SOH_CELL_33

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 223 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 34 RENAULT_SOH_CELL_34

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 222 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 35 RENAULT_SOH_CELL_35

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 221 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 36 RENAULT_SOH_CELL_36

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 220 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 37 RENAULT_SOH_CELL_37

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 219 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 38 RENAULT_SOH_CELL_38

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 218 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 39 RENAULT_SOH_CELL_39

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 217 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 40 RENAULT_SOH_CELL_40

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 216 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 41 RENAULT_SOH_CELL_41

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 215 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 42 RENAULT_SOH_CELL_42

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 214 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 43 RENAULT_SOH_CELL_43

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 213 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 44 RENAULT_SOH_CELL_44

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 212 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 45 RENAULT_SOH_CELL_45

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 211 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 46 RENAULT_SOH_CELL_46

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 210 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 47 RENAULT_SOH_CELL_47

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 209 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 48 RENAULT_SOH_CELL_48

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 208 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 49 RENAULT_SOH_CELL_49

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 50 RENAULT_SOH_CELL_50

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 206 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 51 RENAULT_SOH_CELL_51

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 205 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 52 RENAULT_SOH_CELL_52

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 204 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 53 RENAULT_SOH_CELL_53

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 203 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 54 RENAULT_SOH_CELL_54

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 202 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 55 RENAULT_SOH_CELL_55

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 201 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 56 RENAULT_SOH_CELL_56

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 200 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 57 RENAULT_SOH_CELL_57

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 199 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 58 RENAULT_SOH_CELL_58

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 198 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 59 RENAULT_SOH_CELL_59

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 197 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 60 RENAULT_SOH_CELL_60

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 196 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 61 RENAULT_SOH_CELL_61

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 195 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 62 RENAULT_SOH_CELL_62

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 194 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 63 RENAULT_SOH_CELL_63

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 193 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 64 RENAULT_SOH_CELL_64

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 192 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 65 RENAULT_SOH_CELL_65

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 191 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 66 RENAULT_SOH_CELL_66

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 190 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 67 RENAULT_SOH_CELL_67

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 189 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 68 RENAULT_SOH_CELL_68

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 188 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 69 RENAULT_SOH_CELL_69

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 187 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 70 RENAULT_SOH_CELL_70

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 186 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 71 RENAULT_SOH_CELL_71

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 185 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 72 RENAULT_SOH_CELL_72

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 184 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 73 RENAULT_SOH_CELL_73

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 74 RENAULT_SOH_CELL_74

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 75 RENAULT_SOH_CELL_75

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 76 RENAULT_SOH_CELL_76

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 77 RENAULT_SOH_CELL_77

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 78 RENAULT_SOH_CELL_78

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 79 RENAULT_SOH_CELL_79

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 177 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 80 RENAULT_SOH_CELL_80

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 176 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 81 RENAULT_SOH_CELL_81

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 82 RENAULT_SOH_CELL_82

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 174 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 83 RENAULT_SOH_CELL_83

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 173 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 84 RENAULT_SOH_CELL_84

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 172 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 85 RENAULT_SOH_CELL_85

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 86 RENAULT_SOH_CELL_86

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 87 RENAULT_SOH_CELL_87

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 169 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 88 RENAULT_SOH_CELL_88

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 168 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 89 RENAULT_SOH_CELL_89

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 167 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 90 RENAULT_SOH_CELL_90

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 166 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 91 RENAULT_SOH_CELL_91

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 165 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 92 RENAULT_SOH_CELL_92

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 164 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 93 RENAULT_SOH_CELL_93

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 163 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 94 RENAULT_SOH_CELL_94

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 162 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 95 RENAULT_SOH_CELL_95

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 161 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State of health cell 96 RENAULT_SOH_CELL_96

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 160 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

State stop and start activation control RENAULT_ST_STOP_START

  • Service 22DID 2B0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Static regeneration, in workshop RENAULT_STATIC_REGEN

  • Service 22DID 11A2
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Static regeneration, in workshop RENAULT_STATIC_REGEN_V2

  • Service 22DID 2434
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Steering motor torque set point RENAULT_STEER_MOTOR_TQ

  • Service 21PID 01
  • Module742
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2015 to 2026.

Stop and start function RENAULT_STOP_START_FUNCTION

  • Service 22DID 2953
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Stop and start function RENAULT_STOP_START_FUNCTION_2

  • Service 22DID 2953
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Stop and start function RENAULT_STOP_START_FUNCTION_DADA

  • Service 22DID 2930
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Stop and start inhibition, anti-lock brakes RENAULT_S_S_INHIBITION_ABS

  • Service 22DID 3079
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Stop warning light RENAULT_STOP_WARN_LIGHT_2

  • Service 22DID 2170
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Sulphur oxide mass 1 RENAULT_SULPHUR_OXIDE_MASS_1

  • Service 22DID 21E5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 g
Unit
g

In testing for 2015 to 2026.

Sunshine RENAULT_SUNSHINE

  • Service 21PID 43
  • Module744 → 764
  • Every5 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Swirl flap OCR RENAULT_SWIRL_FLAP_OCR

  • Service 22DID 2594
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Swirl flap position RENAULT_SWIRL_FLAP_POS_7E0

  • Service 22DID 2591
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2505123
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Swirl flap position reference value RENAULT_SWIRL_FLAP_POS

  • Service 22DID 259C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250−1699.054
Range
-1699 to 1499 %
Unit
%

In testing for 2015 to 2026.

Swirl flap programming closed RENAULT_SWIRL_FLAP_PROGRAMMING

  • Service 22DID 2581
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Swirl flap programming open RENAULT_SWIRL_FLAP

  • Service 22DID 2582
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Synchronisation status RENAULT_SYNCHRONISATION_STAT

  • Service 22DID 2046
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

System status RENAULT_SYSTEM_STAT

  • Service 22DID 233C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2015 to 2026.

Tailgate / boot lid RENAULT_TAILGATE_BOOT_LID

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Tank pressure RENAULT_TANK_P

  • Service 22DID F432
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191
Unit
Number

In testing for 2015 to 2026.

Target line pressure RENAULT_TGT_LINE_P

  • Service 22DID 1127
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 bar
Unit
bar

In testing for 2015 to 2026.

Temperature sensor module number 1 RENAULT_T_SENS_MODULE_N_1

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Temperature sensor module number 2 RENAULT_T_SENS_MODULE_N_2

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Temperature sensor module number 3 RENAULT_T_SENS_MODULE_N_3

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Temperature sensor module number 4 RENAULT_T_SENS_MODULE_N_4

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Temperature sensor module number 5 RENAULT_T_SENS_MODULE_N_5

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Temperature sensor module number 6 RENAULT_T_SENS_MODULE_N_6

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Temperature sensor module number 7 RENAULT_T_SENS_MODULE_N_7

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Temperature sensor module number 8 RENAULT_T_SENS_MODULE_N_8

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Temperature sensor module number 9 RENAULT_T_SENS_MODULE_N_9

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Temperature sensor module number 10 RENAULT_T_SENS_MODULE_N_10

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Temperature sensor module number 11 RENAULT_T_SENS_MODULE_N_11

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Temperature sensor module number 12 RENAULT_T_SENS_MODULE_N_12

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Temperature signal RENAULT_T_SIG

  • Service 22DID 20A1
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 °C
Unit
°C

In testing for 2015 to 2026.

Temperature signal RENAULT_T_SIG_7E1

  • Service 22DID 2348
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2015 to 2026.

Temperature signal RENAULT_T_SIG_V2

  • Service 22DID 003C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Temperature upstream of turbine RENAULT_T_UP_TURBINE

  • Service 22DID 2439
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Temperature. downstream of particle filter RENAULT_T_DN_PARTICLE_FLT

  • Service 22DID 2441
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

In testing for 2015 to 2026.

Temperature. downstream of particle filter RENAULT_T_DN_PARTICLE_FLT_2

  • Service 22DID 2441
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

In testing for 2015 to 2026.

Temperature. upstream of particle filter RENAULT_T_UP_PARTICLE_FLT

  • Service 22DID 2442
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

In testing for 2015 to 2026.

Temperature. upstream of particle filter RENAULT_T_UP_PARTICLE_FLT_2

  • Service 22DID 2442
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

In testing for 2015 to 2026.

Test result 1 RENAULT_TEST_RESULT_1

  • Service 22DID 2493
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Test result 2 RENAULT_TEST_RESULT_2

  • Service 22DID 2494
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Theoretical engine torque RENAULT_THEORETICAL_ENG_TQ

  • Service 22DID 2E45
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Theoretical engine torque RENAULT_THEORETICAL_ENG_TQ_V2

  • Service 22DID 000F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Theoretical idle regulation duty cycle RENAULT_THEORETICAL_IDLE

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×0.001526
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Thermoplunger heater heater heater management RENAULT_THERMOPLUNGER

  • Service 22DID 20FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Thermoplunger no. 1 relay control RENAULT_THERMOPLUNGER_NO_1

  • Service 22DID 201D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Thermoplunger no. 2 relay control RENAULT_THERMOPLUNGER_NO_2

  • Service 22DID 201D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Thermoplunger no. 3 relay control RENAULT_THERMOPLUNGER_NO_3

  • Service 22DID 201D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Throttle body opening RENAULT_THROTTLE_BODY

  • Service 22DID 2404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2015 to 2026.

Throttle limits programming RENAULT_THROTTLE_LIMITS_PROG

  • Service 22DID 245D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Throttle low stop, programmed RENAULT_THROTTLE_LOW_STOP_PROG

  • Service 22DID 2457
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 %
Unit
%

In testing for 2015 to 2026.

Throttle lower limit after offset application RENAULT_THROTTLE_LO_LIM

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val×1001023
Range
0 to 6406 %
Unit
%

In testing for 2015 to 2026.

Throttle opening RENAULT_THROTTLE_OPENING

  • Service 22DID 140F
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×720
Range
0 to 89.25 °
Unit
°

In testing for 2015 to 2026.

Throttle position measured track 1 RENAULT_THROTTLE_POS_MEAS_1

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×4001023
Range
0 to 99.7 %
Unit
%

In testing for 2015 to 2026.

Throttle position measured track 1 RENAULT_THROTTLE_POS_MEAS_1_V2

  • Service 22DID 2415
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2015 to 2026.

Throttle position measured track 1 RENAULT_THROTTLE_POS_MEAS_TRACK_1

  • Service 22DID FDEC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.007294
Range
-239 to 239
Unit
Number

In testing for 2015 to 2026.

Throttle position measured track 2 RENAULT_THROTTLE_POS_MEAS_2

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×4001023
Range
0 to 99.7 %
Unit
%

In testing for 2015 to 2026.

Throttle position measured track 2 RENAULT_THROTTLE_POS_MEAS_2_V2

  • Service 22DID 2416
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2015 to 2026.

Throttle position measured track 2 RENAULT_THROTTLE_POS_MEAS_TRACK_2

  • Service 22DID FDED
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.007294
Range
-239 to 239
Unit
Number

In testing for 2015 to 2026.

Throttle position sensor RENAULT_THROTTLE_POS_SENS

  • Service 22DID F44C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Throttle position sensor RENAULT_THROTTLE_POS_SENS_2

  • Service 22DID 124B
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2015 to 2026.

Throttle position, measured RENAULT_THROTTLE_POS

  • Service 22DID 242F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 %
Unit
%

In testing for 2015 to 2026.

Throttle position, reference RENAULT_THROTTLE_POS_REF

  • Service 22DID 2414
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 %
Unit
%

In testing for 2015 to 2026.

Throttle position, track 1 RENAULT_THROTTLE_POS_1

  • Service 22DID 2415
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 %
Unit
%

In testing for 2015 to 2026.

Throttle position, track 2 RENAULT_THROTTLE_POS_2

  • Service 22DID 2416
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 %
Unit
%

In testing for 2015 to 2026.

Throttle safe mode value, programmed RENAULT_THROTTLE_SAFE_MODE_PROG

  • Service 22DID 24C9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 %
Unit
%

In testing for 2015 to 2026.

Throttle valve safe mode value programmed RENAULT_THROTTLE_VLV_SAFE

  • Service 22DID 24C9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2015 to 2026.

Throttle valve safe mode value programmed RENAULT_THROTTLE_VLV_SAFE_V2

  • Service 22DID FDD4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000152588
Range
-5 to 4.99 V
Unit
V

In testing for 2015 to 2026.

Throttle voltage, track 1 RENAULT_THROTTLE_V1

  • Service 22DID 2418
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Throttle voltage, track 2 RENAULT_THROTTLE_V2

  • Service 22DID 2419
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2015 to 2026.

Time engine run since regeneration RENAULT_TIME_ENG_RUN_SINCE_REGEN

  • Service 22DID 30DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-21474836 to 21474836 s
Unit
s

In testing for 2015 to 2026.

Time engine run since successful regen RENAULT_TIME_ENG_RUN_SINCE

  • Service 22DID 30B5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 h
Unit
h

In testing for 2015 to 2026.

Time since last regeneration RENAULT_TIME_SINCE_REGEN

  • Service 22DID 2488
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2015 to 2026.

Tire pressure warning system RENAULT_TYRE_P_WARN_SYSTEM

  • Service 22DID 4C28
  • Module740 → 760
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Top dead center sensor signal RENAULT_TDC_SNS_SIG

  • Service 22DID 2161
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Torque meter correction, adaptive RENAULT_TORQUEMETER_ADAPT_CORR

  • Service 22DID 215D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767
Unit
Number

In testing for 2015 to 2026.

Torque meter value, programmed RENAULT_TORQUEMETER_PROG

  • Service 22DID 2156
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Torque set point programming RENAULT_TORQUE_SETPT_PROG

  • Service 22DID 3011
  • Module748
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Torque, applied RENAULT_TORQUE_APPLIED

  • Service 22DID 302C
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 N·m
Unit
N·m

In testing for 2015 to 2026.

Torque, requested RENAULT_TORQUE_REQ

  • Service 22DID 3025
  • Module748
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2015 to 2026.

Total sum of the engine on time, h RENAULT_TOT_SUM_ENG_ON_TIME_H

  • Service 22DID 30D8
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val3600
Range
-596523 to 596523 h
Unit
h

In testing for 2015 to 2026.

Toxicity sensor RENAULT_TOXICITY_SENS

  • Service 21PID 0B
  • Module744 → 764
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Traction control RENAULT_TC

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Traction control RENAULT_TRACTION_CTRL

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Traction control function RENAULT_TRACTION_CTRL_FUNCTION_740_2

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Traction control on/off button RENAULT_TRACTION_CTRL_ON_OFF

  • Service 22DID 4B0D
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Traction control, deactivated RENAULT_TC_OFF

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Traction control, warning RENAULT_TC_WARN

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Traction control/anti-yaw control RENAULT_TRACTION_CTRL_ANTI

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Traction control/anti-yaw control RENAULT_TRACTION_CTRL_ANTI_V2

  • Service 22DID 2079
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Trailer present RENAULT_TRAILER_PRESENT

  • Service 22DID 4B4A
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Trailer stability RENAULT_TRAILER_STAB

  • Service 22DID 4B2E
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Trajectory control RENAULT_TRAJ_CTRL

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Trajectory control, warning RENAULT_TRAJ_CTRL_WARN

  • Service 22DID 4B35
  • Module740 → 760
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Transition from LPG mode to petrol mode RENAULT_TRANSITION_LPG_MODE

  • Service 22DID 28AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Transition from petrol mode to LPG mode RENAULT_TRANSITION_PETROL

  • Service 22DID 28AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Transmitted throttle position value RENAULT_TRANSMITTED_THROTTLE

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4001023
Range
0 to 99.7 %
Unit
%

In testing for 2015 to 2026.

Transmitted throttle position value RENAULT_TRANSMITTED_THROTTLE_V2

  • Service 22DID 2536
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 %
Unit
%

In testing for 2015 to 2026.

Trip computer display type RENAULT_ADAC_DISPLAY_TYPE

  • Service 22DID 0106
  • Module743 → 763
  • Every1 s
  • Testing

Bits 6 to 7 of the reply, 2 bits.

Formula
val
Range
0 to 3
Unit
Number

In testing for 2015 to 2026.

Turbine upstream temperature set point RENAULT_TURBINE_UP_T

  • Service 22DID 2438
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Turbo electric water pump command RENAULT_TURBO_ELEC_WATER_PMP

  • Service 22DID 24BF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Turbo position set point RENAULT_TURBO_POS_SETPOINT

  • Service 22DID 25C5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Turbo regulation RENAULT_TURBO_REGULATION

  • Service 22DID 241E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Turbo wastegate valve position RENAULT_TURBO_WASTEGATE_VLV

  • Service 22DID 25C6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×611250
Range
0 to 3198 %
Unit
%

In testing for 2015 to 2026.

Turbocharging solenoid valve duty cycle setting RENAULT_TURBOCHARGING_S_V

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2015 to 2026.

Turbocharging solenoid valve OCR RENAULT_TURBOCHARGING

  • Service 22DID 2403
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2015 to 2026.

Upstream O2 sensor heating RENAULT_UP_O2_SENS_HEATING_V2

  • Service 22DID 2506
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Upstream O2 sensor heating duty cycle RENAULT_UP_O2_SENS_HEATING_2

  • Service 22DID 114E
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 102 %
Unit
%

In testing for 2015 to 2026.

Upstream o2 sensor heating OCR RENAULT_UP_O2_SENS_HEATING

  • Service 22DID 244B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val3
Range
0 to 85 %
Unit
%

In testing for 2015 to 2026.

Upstream oxygen sensor RENAULT_UP_OXYGEN_SENS

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Upstream oxygen sensor circuit RENAULT_UP_OXYGEN_SENS_CIRCUIT

  • Service 22DID 251A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Upstream oxygen sensor reset RENAULT_UP_OXYGEN_SENS_RESET

  • Service 22DID FE68
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Vacuum pump aging counter RENAULT_VACUUM_PMP_AGEING

  • Service 22DID 2892
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100
Range
0 to 6553500 s
Unit
s

In testing for 2015 to 2026.

Vacuum sensor circuit RENAULT_VACUUM_SENS_CIRCUIT

  • Service 22DID 4B4E
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750
Unit
Raw value

In testing for 2015 to 2026.

Vacuum sensor circuit RENAULT_VACUUM_SENS_CIRCUIT_V2

  • Service 22DID 4B4F
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Vacuum sensor pressure RENAULT_VACUUM_P

  • Service 22DID 4B4E
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 bar
Unit
bar

In testing for 2015 to 2026.

Vehicle status RENAULT_VEH

  • Service 22DID 4B1A
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Vehicle status RENAULT_VEH_STAT

  • Service 22DID 2B0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Vehicle status recognition RENAULT_VEH_STAT_RECOGNITION

  • Service 22DID 301A
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Vehicle type RENAULT_VEH_TYPE

  • Service 21PID 80
  • Module752 → 772
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Water in diesel detector RENAULT_WATER_DIESEL

  • Service 22DID FD70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Water in diesel detector RENAULT_WATER_DIESEL_DETECTOR

  • Service 22DID 2171
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Water pump command RENAULT_WATER_PMP_COMMAND

  • Service 22DID 2264
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Water pump relay RENAULT_WATER_PMP_RELAY

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Water temperature RENAULT_WATER_T

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
val×516−40
Range
-40 to 20439 °C
Unit
°C

In testing for 2015 to 2026.

Water temperature RENAULT_WATER_T_2

  • Service 22DID 1101
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2015 to 2026.

Water temperature RENAULT_WATER_T_743

  • Service 21PID 10
  • Module743 → 763
  • Every5 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Water temperature RENAULT_WATER_T_7E0

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The value is signed.

Formula
val10−273
Range
-3549 to 3003 °C
Unit
°C

In testing for 2015 to 2026.

Water temperature RENAULT_WATER_T_7E1

  • Service 21PID A7
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2015 to 2026.

Water temperature RENAULT_WATER_T_V2

  • Service 22DID 2001
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Weight of soot after regeneration RENAULT_WEIGHT_SOOT_AFTER

  • Service 22DID 24A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 g
Unit
g

In testing for 2015 to 2026.

Windscreen wiper intermittent setting RENAULT_WINDSCREEN_WIPER

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Wiper stalk position RENAULT_WIPER_STALK_POS

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

With swirl flap RENAULT_SWIRL_FLAP_V2

  • Service 22DID 20DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Yaw angle RENAULT_YAW_ANG

  • Service 22DID 4B0C
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5−6553.4
Range
-6553 to 6553
Unit
Raw value

In testing for 2015 to 2026.

Fuel

Alcohol fuel adaptive correction RENAULT_ALCOHOL_FUEL

  • Service 22DID 287B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Current fuel level RENAULT_CURRENT_FLI

  • Service 22DID 2201
  • Module743 → 763
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 L
Unit
L

In testing for 2015 to 2026.

Fuel consumption since the last regeneration RENAULT_FUEL_CONS_SINCE_LAST

  • Service 22DID 30DC
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-2147483 to 2147483 L
Unit
L

In testing for 2015 to 2026.

Fuel flow RENAULT_FUEL_FLOW

  • Service 21PID 12
  • Module743 → 763
  • Every30 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2015 to 2026.

Fuel flow RENAULT_FUEL_FLOW_7E0

  • Service 21PID A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2015 to 2026.

Fuel flow RENAULT_FUEL_FLOW_7E0_V2

  • Service 22DID 28C6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2563125
Range
0 to 5368
Unit
Raw value

In testing for 2015 to 2026.

Fuel flow RENAULT_FUEL_FLOW_V2

  • Service 22DID 2806
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Raw value

In testing for 2015 to 2026.

Fuel flow correction cylinder n°1 RENAULT_FUEL_FLOW_CORR_CYL_N_1_7E0

  • Service 21PID A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2015 to 2026.

Fuel flow correction cylinder n°4 RENAULT_FUEL_FLOW_CORR_CYL_N_4_7E0

  • Service 21PID A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 160 to 175 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2015 to 2026.

Fuel flow correction cylinder number 1 RENAULT_FUEL_FLOW_CORR_CYL_N_1

  • Service 22DID FD38
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Fuel flow correction cylinder number 4 RENAULT_FUEL_FLOW_CORR_CYL_N_4

  • Service 22DID FD3B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

In testing for 2015 to 2026.

Fuel flow correction for cylinder no. 2 RENAULT_FUEL_FLOW_CORR_CYL_2

  • Service 22DID FD39
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

In testing for 2015 to 2026.

Fuel flow correction for cylinder no. 2 RENAULT_FUEL_FLOW_CORR_CYL_NO_2

  • Service 21PID A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2015 to 2026.

Fuel flow correction for cylinder no. 3 RENAULT_FUEL_FLOW_CORR_CYL_3

  • Service 22DID 285C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×3
Range
0 to 765 %
Unit
%

In testing for 2015 to 2026.

Fuel flow correction for cylinder no. 3 RENAULT_FUEL_FLOW_CORR_CYL_3_V2

  • Service 22DID FD3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2015 to 2026.

Fuel flow correction for cylinder no. 3 RENAULT_FUEL_FLOW_CORR_CYL_NO_3

  • Service 21PID A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2015 to 2026.

Fuel flow correction for cylinder no. 3 RENAULT_FUEL_FLOW_CORR_CYL_NO_3_V2

  • Service 22DID FD3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

In testing for 2015 to 2026.

Fuel flow reference RENAULT_FUEL_FLOW_REFERENCE

  • Service 21PID A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327
Unit
Raw value

In testing for 2015 to 2026.

Fuel flow solenoid valve, current RENAULT_FUEL_FLOW_SOLENOID

  • Service 22DID FDE9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 2015 to 2026.

Fuel flow solenoid valve, current RENAULT_FUEL_FLOW_SOLENOID_VLV

  • Service 21PID A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 2015 to 2026.

Fuel gauge resistor RENAULT_FUEL_GAUGE_RESISTOR

  • Service 21PID 12
  • Module743 → 763
  • Every30 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 Ω
Unit
Ω

In testing for 2015 to 2026.

Fuel level RENAULT_FLI

  • Service 21PID 12
  • Module743 → 763
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 655 L
Unit
L

In testing for 2015 to 2026.

Fuel level RENAULT_FLI_7E0

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Fuel level displayed RENAULT_FLI_DISPLAYED

  • Service 22DID 2203
  • Module743 → 763
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 L
Unit
L

In testing for 2015 to 2026.

Fuel pressure regulation RENAULT_FUEL_P_REGULATION

  • Service 22DID 301A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fuel pump control signal RENAULT_FUEL_PMP_CTRL_SIG

  • Service 22DID 129C
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Fuel pump duty cycle RENAULT_FUEL_PMP_OCR

  • Service 22DID FDC4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fuel pump duty cycle RENAULT_FUEL_PMP_OCR_2

  • Service 22DID 117F
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Fuel pump priming complete RENAULT_FUEL_PMP_PRIMING

  • Service 22DID 2862
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fuel pump priming complete RENAULT_FUEL_PMP_PRIMING_COMPLETE

  • Service 22DID 2885
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Fuel pump relay RENAULT_FUEL_PMP_RELAY

  • Service 22DID 1308
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Fuel pump relay RENAULT_FUEL_PMP_RELAY_V2

  • Service 22DID 2882
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Fuel rail pressure RENAULT_FUEL_RAIL_P

  • Service 22DID 2801
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×6.894757293
Range
0 to 451847 kPa
Unit
kPa

In testing for 2015 to 2026.

Fuel tank level, estimated RENAULT_FLI_EST

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 2881
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Fuel tank temperature RENAULT_FUEL_TANK_T

  • Service 22DID 28FF
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Fuel temperature RENAULT_FUEL_T

  • Service 22DID 1111
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2015 to 2026.

Fuel temperature RENAULT_FUEL_T_7E0

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The value is signed.

Formula
val10−273
Range
-3549 to 3003 °C
Unit
°C

In testing for 2015 to 2026.

Fuel temperature RENAULT_FUEL_T_V2

  • Service 22DID 2008
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Fuel temperature RENAULT_GAS_T

  • Service 22DID 28B1
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280.5 °C
Unit
°C

In testing for 2015 to 2026.

Fuel used since trip computer reset RENAULT_FUEL_USED_SINCE_ADAC

  • Service 21PID 12
  • Module743 → 763
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 L
Unit
L

In testing for 2015 to 2026.

Injection pump fuel PWM RENAULT_INJ_PMP_FUEL_PWM

  • Service 22DID 2933
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280 °C
Unit
°C

In testing for 2015 to 2026.

Instantaneous fuel consumption RENAULT_INSTANTANEOUS_FUEL

  • Service 21PID A9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 L
Unit
L

In testing for 2015 to 2026.

Linearized fuel temperature RENAULT_LINEARISED_FUEL_T

  • Service 22DID FD41
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647 °C
Unit
°C

In testing for 2015 to 2026.

Long term fuel trim RENAULT_LONG_TERM_FUEL_TRIM

  • Service 22DID 1125
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Low fuel level information RENAULT_LOW_FLI_INFORMATION

  • Service 22DID 281B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Memorized variable of the fuel level RENAULT_MEMORIZED_VARIABLE

  • Service 22DID 287F
  • ModuleDA15 → 15
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2015 to 2026.

Of fuel pump actuator, PWM RENAULT_PWM_FUEL_PMP

  • Service 22DID 2887
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2015 to 2026.

Raw UEGO air fuel ratio measurement RENAULT_RAW_UEGO_AIR_FUEL

  • Service 22DID 251E
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000305176
Range
0 to 1.99
Unit
Number

In testing for 2015 to 2026.

Short term fuel trim RENAULT_SHORT_TERM_FUEL_TRIM

  • Service 22DID 1123
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Lights

Diagnostic light request RENAULT_OBD_LIGHT_REQ

  • Service 22DID 2028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Low beams on RENAULT_LOW_BEAM

  • Service 22DID 4186
  • Module745 → 765
  • Every3 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Stop warning light RENAULT_STOP_WARN_LIGHT

  • Service 22DID 2170
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Warning light RENAULT_WARNING_LIGHT

  • Service 22DID 3024
  • Module748
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Warning light management, OBD RENAULT_OBD_WARN_LIGHT

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Movement

Acceleration offset, lateral RENAULT_ACCEL_LAT_OFFSET

  • Service 22DID 4B37
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 g
Unit
g

In testing for 2015 to 2026.

Acceleration offset, longitudinal RENAULT_ACCEL_LONG_OFFSET

  • Service 22DID 4B38
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Acceleration pedal calculated position RENAULT_ACCEL_PEDAL_CALC_POS

  • Service 22DID 2044
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Acceleration pedal position for change down RENAULT_ACCEL_PEDAL_POS_CHANGE

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2015 to 2026.

Acceleration sensor RENAULT_ACCEL_SENS

  • Service 22DID 130F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Acceleration, lateral RENAULT_ACCEL_LAT

  • Service 22DID 4B0B
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 g
Unit
g

In testing for 2015 to 2026.

Acceleration, longitudinal RENAULT_ACCEL_LONG

  • Service 22DID 4B07
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Accelerator pedal position RENAULT_ACCEL_PEDAL_POS

  • Service 21PID A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2015 to 2026.

Accelerator pedal position RENAULT_ACCEL_PEDAL_POS_7E0

  • Service 21PID A1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits. The value is signed.

Formula
val×0.01220703
Range
-399 to 399 %
Unit
%

In testing for 2015 to 2026.

Accelerator pedal position RENAULT_ACCEL_PEDAL_POS_7E0_V2

  • Service 22DID 202E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val800
Range
0 to 81.91 %
Unit
%

In testing for 2015 to 2026.

Accelerator pedal position RENAULT_ACCEL_PEDAL_POS_7E1

  • Service 21PID A1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 %
Unit
%

In testing for 2015 to 2026.

Accelerator pedal position RENAULT_ACCEL_PEDAL_POS_7E1_2

  • Service 22DID 1117
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1651
Range
0 to 80 °
Unit
°

In testing for 2015 to 2026.

Accelerator pedal position RENAULT_ACCEL_PEDAL_POS_7E1_2_V2

  • Service 22DID 004D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2015 to 2026.

Accelerator pedal position RENAULT_ACCEL_PEDAL_POS_V2

  • Service 22DID 202E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val800
Range
0 to 81.91
Unit
Number

In testing for 2015 to 2026.

Accelerator pedal position RENAULT_ACCEL_PEDAL_POS_V3

  • Service 22DID 202E
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val800
Range
0 to 81.91 %
Unit
%

In testing for 2015 to 2026.

Accelerator pedal position RENAULT_ACCEL_POS

  • Service 22DID 202E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val800
Range
0 to 81.9187 %
Unit
%

In testing for 2015 to 2026.

Accelerator pedal position RENAULT_ACCEL_POS_TC

  • Service 22DID 300A
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Accelerator pedal pressed speed RENAULT_ACCEL_PEDAL_PRESSED

  • Service 22DID 2D49
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Accelerator position RENAULT_ACCEL_POS_V2

  • Service 22DID 0063
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 %
Unit
%

In testing for 2015 to 2026.

Actual vehicle speed info. absent RENAULT_ACT_VSS_INFO_ABSENT

  • Service 22DID 204E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Actual vehicle speed info. absent RENAULT_ACT_VSS_INFO_ABSENT_2

  • Service 22DID 204E
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Actual vehicle speed info. unavailable RENAULT_ACT_VSS_INFO

  • Service 22DID 204E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Actual vehicle speed info. unavailable RENAULT_ACT_VSS_INFO_V2

  • Service 22DID 204E
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Change of vehicle speed unit RENAULT_CHANGE_VSS_UNIT

  • Service 22DID 204E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Change of vehicle speed unit RENAULT_CHANGE_VSS_UNIT_7E0

  • Service 22DID 2170
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Change of vehicle speed unit RENAULT_CHANGE_VSS_UNIT_DADA

  • Service 22DID 204E
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Change of vehicle speed unit RENAULT_CHANGE_VSS_UNIT_V2

  • Service 22DID 2170
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Column rotation speed RENAULT_COLUMN_ROT_SPD

  • Service 21PID 01
  • Module742
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2015 to 2026.

Compressor speed reference RENAULT_COMP_SPD_REFERENCE

  • Service 21PID 67
  • Module744 → 764
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2015 to 2026.

Cooling pump, target speed RENAULT_COOLING_PMP_TGT_SPD

  • Service 22DID 12A9
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×252
Range
0 to 819187 rpm
Unit
rpm

In testing for 2015 to 2026.

Cruise control/speed limiter buttons RENAULT_CRUISE_CTRL_SPD

  • Service 22DID 204B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cruise control/speed limiter buttons RENAULT_CRUISE_CTRL_SPD_2

  • Service 22DID 204B
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cruise control/speed limiter buttons RENAULT_CRUISE_CTRL_SPD_LIMITER_BUTTONS

  • Service 22DID 2041
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cruise control/speed limiter buttons RENAULT_CRUISE_CTRL_SPD_LIMITER_BUTTONS_2

  • Service 22DID 2A92
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cruise control/speed limiter deactivation RENAULT_CRUISE_CTRL_SPD_LIMITER_2

  • Service 22DID 2079
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Cruise control/speed limiter deactivation RENAULT_CRUISE_CTRL_SPD_LIMITER_DEACTIVATION

  • Service 22DID 2AC8
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cruise control/speed limiter function RENAULT_CRUISE_CTRL_SPD_LIMITER

  • Service 22DID 204C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Cruise control/speed limiter function RENAULT_CRUISE_CTRL_SPD_LIMITER_FUNCTION

  • Service 22DID 204C
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Current engine speed RENAULT_CURRENT_RPM

  • Service 22DID 2002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Current turbine speed RENAULT_CURRENT_TURBINE_SPD

  • Service 21PID A5
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2015 to 2026.

Displayed vehicle speed info. absent RENAULT_DISPLAYED_VSS_INFO

  • Service 22DID 204E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Displayed vehicle speed info. absent RENAULT_DISPLAYED_VSS_INFO_V2

  • Service 22DID 204E
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Displayed vehicle speed unavailable RENAULT_DISPLAYED_VSS

  • Service 22DID 204E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Displayed vehicle speed unavailable RENAULT_DISPLAYED_VSS_V2

  • Service 22DID 204E
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Engine fan high speed relay control RENAULT_ENG_FAN_HIGH_SPD

  • Service 21PID 10
  • Module74D → 76D
  • Every5 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engine speed RENAULT_RPM

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2015 to 2026.

Engine speed RENAULT_RPM_2

  • Service 22DID 1201
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×252
Range
0 to 819187 rpm
Unit
rpm

In testing for 2015 to 2026.

Engine speed RENAULT_RPM_743

  • Service 21PID 10
  • Module743 → 763
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2015 to 2026.

Engine speed RENAULT_RPM_7E1

  • Service 21PID A7
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 rpm
Unit
rpm

In testing for 2015 to 2026.

Engine speed RENAULT_RPM_7E1_2

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2015 to 2026.

Engine speed RENAULT_RPM_7E1_2_V2

  • Service 22DID 004B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engine speed RENAULT_RPM_7E1_V2

  • Service 22DID 0004
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Engine speed RENAULT_RPM_DADA

  • Service 22DID F40C
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Engine speed RENAULT_RPM_V2

  • Service 21PID A7
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Engine speed information RENAULT_RPM_INFORMATION

  • Service 22DID FDB5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2015 to 2026.

Engine speed information RENAULT_RPM_INFORMATION_7E1

  • Service 22DID 2304
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Engine speed information RENAULT_RPM_INFORMATION_V2

  • Service 22DID 000C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2015 to 2026.

Engine speed required by air con RENAULT_RPM_REQUIRED_AIR_CON

  • Service 21PID A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2015 to 2026.

Engine speed required by air con RENAULT_RPM_REQUIRED_AIR_CON_V2

  • Service 22DID 2098
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Fan speed RENAULT_FAN_SPD

  • Service 21PID 21
  • Module744 → 764
  • Every5 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Fan speed RENAULT_FAN_SPD_DADB

  • Service 22DID 912E
  • ModuleDADB → DAF1DB
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2015 to 2026.

Fan speed RENAULT_FAN_SPD_DADB_2

  • Service 22DID 91F0
  • ModuleDADB → DAF1DB
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

FAN SPEED, raw count RENAULT_FAN_SPD_RAW_CNT

  • Service 21PID 21
  • Module744 → 764
  • Every5 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Fast idle speed RENAULT_FAST_IDLE_SPD

  • Service 22DID 205F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Fast idle speed function RENAULT_FAST_IDLE_SPD_FUNCTION

  • Service 22DID 209B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

FL wheel speed RENAULT_FL_VSS

  • Service 22DID 4B00
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km/h
Unit
km/h

In testing for 2015 to 2026.

FL wheel speed RENAULT_FL_VSS_V2

  • Service 22DID 3006
  • Module748
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 rpm
Unit
rpm

In testing for 2015 to 2026.

FR wheel speed RENAULT_FR_VSS

  • Service 22DID 4B01
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km/h
Unit
km/h

In testing for 2015 to 2026.

FR wheel speed RENAULT_FR_VSS_V2

  • Service 22DID 3006
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 rpm
Unit
rpm

In testing for 2015 to 2026.

Idle speed correction RENAULT_IDLE_SPD_CORR

  • Service 22DID 112E
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×252
Range
0 to 3187 rpm
Unit
rpm

In testing for 2015 to 2026.

Idle speed reference RENAULT_IDLE_SPD_REFERENCE

  • Service 22DID 2024
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Idle speed reference RENAULT_IDLE_SPD_REFERENCE_7E0

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2015 to 2026.

Idle speed regulation RENAULT_IDLE_SPD_REGULATION

  • Service 22DID 205A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Input shaft speed sensor 1 supply RENAULT_INPUT_SHFT_SPD_SENS_1

  • Service 22DID 2344
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55 V
Unit
V

In testing for 2015 to 2026.

Input shaft speed sensor 1 supply RENAULT_INPUT_SHFT_SPD_SENS_1_V2

  • Service 22DID 000A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 %
Unit
%

In testing for 2015 to 2026.

Input shaft speed sensor 2 supply RENAULT_INPUT_SHFT_SPD_SENS_2

  • Service 22DID 2345
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55 V
Unit
V

In testing for 2015 to 2026.

Input shaft speed sensor 2 supply RENAULT_INPUT_SHFT_SPD_SENS_2_V2

  • Service 22DID 000B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2015 to 2026.

Input shaft speed sensors RENAULT_INPUT_SHFT_SPD

  • Service 21PID 69
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2015 to 2026.

Longitudinal acceleration RENAULT_LONGITUDINAL_ACCEL

  • Service 22DID 4B07
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−12.7
Range
-12.7 to 12.8
Unit
Number

In testing for 2015 to 2026.

Longitudinal acceleration programming offset RENAULT_LONGITUDINAL_ACCEL_PROGRAMMING

  • Service 22DID 4B38
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×98110000−12.46
Range
-12.46 to 12.55
Unit
Number

In testing for 2015 to 2026.

Maximum permissible speed RENAULT_MAX_PERMISSIBLE_SPD

  • Service 22DID 2184
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Maximum vehicle speed RENAULT_MAX_VSS

  • Service 22DID 219B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Pump speed RENAULT_PMP_SPD

  • Service 22DID 2B5B
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

RL wheel speed RENAULT_RL_VSS

  • Service 22DID 4B02
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km/h
Unit
km/h

In testing for 2015 to 2026.

RL wheel speed RENAULT_RL_VSS_V2

  • Service 22DID 3006
  • Module748
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 rpm
Unit
rpm

In testing for 2015 to 2026.

RR wheel speed RENAULT_RR_VSS

  • Service 22DID 4B03
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km/h
Unit
km/h

In testing for 2015 to 2026.

RR wheel speed RENAULT_RR_VSS_V2

  • Service 22DID 3006
  • Module748
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 rpm
Unit
rpm

In testing for 2015 to 2026.

Secondary pulley speed RENAULT_SECONDARY_PULLEY_SPD

  • Service 22DID 110F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×64
Range
0 to 16320 rpm
Unit
rpm

In testing for 2015 to 2026.

Shaft speed 1 raw value RENAULT_SHFT_SPD_1_RAW

  • Service 22DID 2383
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Shaft speed 2 raw value RENAULT_SHFT_SPD_2_RAW

  • Service 22DID 2384
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Speed limiter RENAULT_SPD_LIMITER

  • Service 21PID D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 108 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Speed limiter RENAULT_SPD_LIMITER_7E0

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Speed limiter RENAULT_SPD_LIMITER_V2

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Speed limiter function RENAULT_SPD_LIMITER_FUNCTION

  • Service 22DID 203D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Speed limiter function RENAULT_SPD_LIMITER_FUNCTION_2

  • Service 22DID 203D
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Speed sensor connection RENAULT_SPD_SENS_CONNECTION

  • Service 22DID 2149
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2015 to 2026.

Speedo index RENAULT_SPEEDO_INDEX

  • Service 22DID 3043
  • Module748
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Speedometer index RENAULT_SPEEDO_IDX

  • Service 22DID 4B24
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mm
Unit
mm

In testing for 2015 to 2026.

Steering wheel angle RENAULT_STEER_ANGLE

  • Service 22DID 0100
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767 °
Unit
°

In testing for 2015 to 2026.

Steering wheel angle, offset RENAULT_STEER_ANGLE_OFFSET

  • Service 22DID 4B36
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2015 to 2026.

Steering wheel speed RENAULT_STEER_SPD

  • Service 22DID 4B42
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767
Unit
Raw value

In testing for 2015 to 2026.

Transverse accel programming offset RENAULT_TRANSVERSE_ACCEL_PROGRAMMING

  • Service 22DID 4B37
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100−1.27
Range
-1.27 to 1.28 g
Unit
g

In testing for 2015 to 2026.

Transverse acceleration RENAULT_TRANSVERSE_ACCEL

  • Service 22DID 4B0B
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50−2.54
Range
-2.54 to 2.56 g
Unit
g

In testing for 2015 to 2026.

Turbine speed RENAULT_TURBINE_SPD

  • Service 21PID A5
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 rpm
Unit
rpm

In testing for 2015 to 2026.

Turbine speed RENAULT_TURBINE_SPD_7E1

  • Service 22DID 110D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2015 to 2026.

Turbine speed/engine speed difference RENAULT_TURBINE_SPD_RPM_DIFF

  • Service 21PID A5
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 rpm
Unit
rpm

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS

  • Service 22DID 4B04
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_740

Pelican can show this parameter as the speed.

  • Service 22DID 4B04
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_743

  • Service 21PID 10
  • Module743 → 763
  • Every5 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_745

  • Service 21PID 10
  • Module745 → 765
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_7E0

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_7E0_2

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_7E0_V2

  • Service 22DID 2003
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_7E1

  • Service 21PID A7
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_7E1_2

  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_7E1_V2

  • Service 22DID 004C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78150000
Range
-511 to 511 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_7E4

  • Service 22DID 2003
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_DADA

  • Service 22DID 2003
  • ModuleDADA → DAF1DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_DADA_2

  • Service 22DID 1102
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_TC

Pelican can show this parameter as the speed.

  • Service 22DID 3008
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_V2

Pelican can show this parameter as the speed.

  • Service 22DID 2003
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed RENAULT_VSS_V3

Pelican can show this parameter as the speed.

  • Service 22DID 2003
  • ModuleDADA → DAF1DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed / engine speed ratio RENAULT_VSS_RPM_RAT

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The value is signed.

Formula
val100000
Range
-0.327 to 0.327
Unit
Number

In testing for 2015 to 2026.

Vehicle speed connection type RENAULT_VSS_CONNECTION_TYPE

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 51 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Vehicle speed consistency RENAULT_VSS_CONSISTENCY

  • Service 22DID 204E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Vehicle speed consistency RENAULT_VSS_CONSISTENCY_V2

  • Service 22DID 204E
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Vehicle speed displayed RENAULT_VSS_DISPLAYED

  • Service 22DID 2226
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Vehicle speed displayed RENAULT_VSS_DISPLAYED_7E0

  • Service 22DID 2050
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed information RENAULT_VSS_INFORMATION_V2

  • Service 22DID 2050
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed information circuit RENAULT_VSS_INFORMATION

  • Service 22DID 22B1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Vehicle speed multiplexed information RENAULT_VSS_MULTIPLEXED

  • Service 22DID 2225
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Vehicle speed multiplexed information RENAULT_VSS_MULTIPLEXED_2

  • Service 22DID 2225
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Vehicle speed recalculated by pas RENAULT_VSS_RECALCULATED_PAS

  • Service 21PID 01
  • Module742
  • Every5 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed sensor RENAULT_VSS_SENS

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2015 to 2026.

Vehicle speed unit RENAULT_VSS_UNIT

  • Service 22DID 2051
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Vehicle speed, CAN RENAULT_CAN_VSS

  • Service 22DID 2102
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 km/h
Unit
km/h

In testing for 2015 to 2026.

Wheel speed sensor, signed RENAULT_WHEEL_SPD_SIGN

  • Service 22DID 4BBB
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Yaw angle RENAULT_YAW

  • Service 22DID 4B0C
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767
Unit
Raw value

In testing for 2015 to 2026.

Seatbelts

Driver's seat belt switch RENAULT_DRIVER_S_SEAT_BELT

  • Service 21PID 10
  • Module743 → 763
  • Every5 s
  • Testing

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Driver's seat belt switch RENAULT_DRIVER_S_SEAT_BELT_SWITCH

  • Service 21PID 06
  • Module752 → 772
  • Every5 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Driver's seat belt switch RENAULT_DRIVER_S_SEAT_BELT_SWITCH_7E0

  • Service 22DID 2B19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Front seat belt retractors RENAULT_FRONT_SEAT_BELT

  • Service 21PID 0B
  • Module752 → 772
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Front seat belt retractors RENAULT_FRONT_SEAT_BELT_RETRACTORS

  • Service 21PID 08
  • Module752 → 772
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Passenger seat belt switch RENAULT_PASSENGER_SEAT_BELT

  • Service 21PID 06
  • Module752 → 772
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Seatbelt warning RENAULT_SEATBELT_WARN

  • Service 21PID 10
  • Module743 → 763
  • Every5 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Tires

Flywheel signal RENAULT_FLYWHEEL_SIG

  • Service 21PID A7
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 80 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Flywheel, target programming RENAULT_FLYWHEEL_TGT

  • Service 22DID 21A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Flywheel, target programming RENAULT_FLYWHEEL_TGT_PROGRAMMING

  • Service 22DID 2147
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Front left tire pressure RENAULT_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 6300
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×34
Range
0 to 767.25 kPa
Unit
kPa

In testing for 2015 to 2026.

Front left tire pressure alert RENAULT_TP_FL_ALERT

  • Service 22DID 4109
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1ALERTAlert
2WARNINGWarning
3ALERTAlert
4WARNINGWarning
5ALERTAlert
6WARNINGWarning
7ALERTAlert

In testing for 2015 to 2026.

Front left tire temperature RENAULT_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID 6310
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−30
Range
-30 to 97 °C
Unit
°C

In testing for 2015 to 2026.

Front left wheel speed RENAULT_FL_HAND_WHL_SPD_SENS

  • Service 22DID 2D44
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val24
Range
-1365 to 1365 rpm
Unit
rpm

In testing for 2015 to 2026.

Front left-hand wheel calibration RENAULT_FL_HAND_WHL

  • Service 22DID 4C23
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Front right tire pressure RENAULT_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 6300
  • Module745 → 765
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×34
Range
0 to 767.25 kPa
Unit
kPa

In testing for 2015 to 2026.

Front right tire pressure RENAULT_TP_FR_V2

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 6301
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×34
Range
0 to 767.25 kPa
Unit
kPa

In testing for 2015 to 2026.

Front right tire pressure alert RENAULT_TP_FR_ALERT

  • Service 22DID 410A
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1ALERTAlert
2WARNINGWarning
3ALERTAlert
4WARNINGWarning
5ALERTAlert
6WARNINGWarning
7ALERTAlert

In testing for 2015 to 2026.

Front right tire pressure record, raw RENAULT_TP_FR_STATUS

  • Service 22DID 6301
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Front right tire temperature RENAULT_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID 6310
  • Module745 → 765
  • Every60 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−30
Range
-30 to 97 °C
Unit
°C

In testing for 2015 to 2026.

Front right tire temperature RENAULT_TT_FR_V2

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID 6311
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−30
Range
-30 to 97 °C
Unit
°C

In testing for 2015 to 2026.

Front right wheel speed RENAULT_FR_HAND_WHL_SPD_SENS

  • Service 22DID 2D43
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val24
Range
-1365 to 1365 rpm
Unit
rpm

In testing for 2015 to 2026.

Front right-hand wheel calibration RENAULT_FR_HAND_WHL

  • Service 22DID 4C24
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Rear left tire pressure RENAULT_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 6300
  • Module745 → 765
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×34
Range
0 to 767.25 kPa
Unit
kPa

In testing for 2015 to 2026.

Rear left tire pressure RENAULT_TP_RL_V2

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 6302
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×34
Range
0 to 767.25 kPa
Unit
kPa

In testing for 2015 to 2026.

Rear left tire pressure alert RENAULT_TP_RL_ALERT

  • Service 22DID 410B
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1ALERTAlert
2WARNINGWarning
3ALERTAlert
4WARNINGWarning
5ALERTAlert
6WARNINGWarning
7ALERTAlert

In testing for 2015 to 2026.

Rear left tire pressure record, raw RENAULT_TP_RL_STATUS

  • Service 22DID 6302
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Rear left tire temperature RENAULT_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID 6310
  • Module745 → 765
  • Every60 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−30
Range
-30 to 97 °C
Unit
°C

In testing for 2015 to 2026.

Rear left tire temperature RENAULT_TT_RL_V2

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID 6312
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−30
Range
-30 to 97 °C
Unit
°C

In testing for 2015 to 2026.

Rear left wheel speed RENAULT_RL_HAND_WHL_SPD_SENS

  • Service 22DID 2D46
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val24
Range
-1365 to 1365 rpm
Unit
rpm

In testing for 2015 to 2026.

Rear left-hand wheel calibration RENAULT_RL_HAND_WHL

  • Service 22DID 4C25
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Rear right tire pressure RENAULT_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 6300
  • Module745 → 765
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×34
Range
0 to 767.25 kPa
Unit
kPa

In testing for 2015 to 2026.

Rear right tire pressure RENAULT_TP_RR_V2

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 6303
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×34
Range
0 to 767.25 kPa
Unit
kPa

In testing for 2015 to 2026.

Rear right tire pressure alert RENAULT_TP_RR_ALERT

  • Service 22DID 410C
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1ALERTAlert
2WARNINGWarning
3ALERTAlert
4WARNINGWarning
5ALERTAlert
6WARNINGWarning
7ALERTAlert

In testing for 2015 to 2026.

Rear right tire pressure record, raw RENAULT_TP_RR_STATUS

  • Service 22DID 6303
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Rear right tire temperature RENAULT_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID 6310
  • Module745 → 765
  • Every60 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−30
Range
-30 to 97 °C
Unit
°C

In testing for 2015 to 2026.

Rear right tire temperature RENAULT_TT_RR_V2

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID 6313
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−30
Range
-30 to 97 °C
Unit
°C

In testing for 2015 to 2026.

Rear right wheel speed RENAULT_RR_HAND_WHL_SPD_SENS

  • Service 22DID 2D45
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val24
Range
-1365 to 1365 rpm
Unit
rpm

In testing for 2015 to 2026.

Rear right-hand wheel calibration RENAULT_RR_HAND_WHL

  • Service 22DID 4C26
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Side on which steering wheel fitted RENAULT_SIDE_ON_WHICH_STEER

  • Service 21PID 02
  • Module752 → 772
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Speed of front l/h wheel RENAULT_SPD_FRONT_L_H_WHL

  • Service 22DID 4B00
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Speed of front l/h wheel RENAULT_SPD_FRONT_L_H_WHL_7E1

  • Service 22DID 0033
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Speed of front l/h wheel RENAULT_SPD_FRONT_L_H_WHL_V2

  • Service 22DID 20FD
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Speed of front r/h wheel RENAULT_SPD_FRONT_R_H_WHL

  • Service 22DID 4B01
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Speed of front r/h wheel RENAULT_SPD_FRONT_R_H_WHL_7E1

  • Service 22DID 0032
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Speed of front r/h wheel RENAULT_SPD_FRONT_R_H_WHL_V2

  • Service 22DID 20FC
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Speed of rear l/h wheel RENAULT_SPD_REAR_L_H_WHL

  • Service 22DID 4B02
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Speed of rear l/h wheel RENAULT_SPD_REAR_L_H_WHL_V2

  • Service 22DID 20FF
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Speed of rear r/h wheel RENAULT_SPD_REAR_R_H_WHL

  • Service 22DID 4B03
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2015 to 2026.

Speed of rear r/h wheel RENAULT_SPD_REAR_R_H_WHL_V2

  • Service 22DID 20FE
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Steering wheel angle RENAULT_STEER_WHL_ANG

  • Service 22DID 0100
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.7
Range
-3276 to 3276 °
Unit
°

In testing for 2015 to 2026.

Steering wheel angle RENAULT_STEER_WHL_ANG_V2

  • Service 21PID 01
  • Module742
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2015 to 2026.

Steering wheel angle offset compensation RENAULT_STEER_WHL_ANG_OFFSET

  • Service 21PID 01
  • Module742
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °
Unit
°

In testing for 2015 to 2026.

Steering wheel angle programming offset RENAULT_STEER_WHL_ANG_PROGRAMMING

  • Service 22DID 4B36
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5−25.4
Range
-25.4 to 25.6 °
Unit
°

In testing for 2015 to 2026.

Steering wheel angle sensor RENAULT_STEER_WHL_ANG_SENS

  • Service 22DID 4BBE
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Steering wheel commands sent to adaptive cruise control ECU RENAULT_STEER_WHL_COMMANDS

  • Service 22DID 2C50
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Steering wheel commands sent to adaptive cruise control ECU RENAULT_STEER_WHL_COMMANDS_2

  • Service 22DID 2C50
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Steering wheel speed RENAULT_STEER_WHL_SPD

  • Service 22DID 4B42
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.7
Range
-3276 to 3276
Unit
Raw value

In testing for 2015 to 2026.

Torque applied to steering wheel RENAULT_TQ_APPLIED_STEER_WHL

  • Service 21PID 01
  • Module742
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.8 to 12.7 N·m
Unit
N·m

In testing for 2015 to 2026.

Transmission

Automatic gearbox in defect mode RENAULT_AUTOMATIC_GEARBOX

  • Service 22DID 204F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Automatic gearbox in defect mode RENAULT_AUTOMATIC_GEARBOX_2

  • Service 22DID 204F
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Automatic gearbox in defect mode RENAULT_AUTOMATIC_GEARBOX_DEFECT

  • Service 22DID 204E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Automatic gearbox in defect mode RENAULT_AUTOMATIC_GEARBOX_DEFECT_V2

  • Service 22DID 204E
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Automatic transmission RENAULT_AUTOMATIC_TRANS

  • Service 22DID 2081
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Camshaft phaser 1 RENAULT_CAM_SHIFTER_1

  • Service 22DID FD93
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Camshaft phaser measured position RENAULT_CAM_SHIFTER_MEAS_POS

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2015 to 2026.

Camshaft phaser measured position RENAULT_CAM_SHIFTER_MEAS_POS_7E0

  • Service 22DID 2255
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 %
Unit
%

In testing for 2015 to 2026.

Camshaft phaser no. 2 RENAULT_CAM_SHIFTER_NO_2

  • Service 22DID FD92
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch RENAULT_CLU

  • Service 22DID 001D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Clutch 1 RENAULT_CLU_1

  • Service 21PID A7
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch 1 estimated torque RENAULT_CLU_1_ESTIMATED_TQ

  • Service 22DID 2E35
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Clutch 1 estimated torque RENAULT_CLU_1_ESTIMATED_TQ_7E1

  • Service 22DID 2312
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Clutch 1 open RENAULT_CLU_1_OPEN

  • Service 22DID 0044
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch 1 pressure RENAULT_CLU_1_P

  • Service 22DID 233D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.99 bar
Unit
bar

In testing for 2015 to 2026.

Clutch 1 pressure RENAULT_CLU_1_P_7E1

  • Service 22DID 2051
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2015 to 2026.

Clutch 1 sensor power supply RENAULT_CLU_1_SENS_POWER_SUP

  • Service 22DID 2052
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Clutch 1 solenoid valve control, current RENAULT_CLU_1_SOLEN_VLV_CTRL

  • Service 22DID 2D37
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 A
Unit
A

In testing for 2015 to 2026.

Clutch 1 temperature RENAULT_CLU_1_T

  • Service 21PID A7
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 °C
Unit
°C

In testing for 2015 to 2026.

Clutch 1 temperature RENAULT_CLU_1_T_7E1

  • Service 22DID 0016
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 °C
Unit
°C

In testing for 2015 to 2026.

Clutch 1 temperature RENAULT_CLU_1_T_7E1_2

  • Service 22DID 00B5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2015 to 2026.

Clutch 1 temperature RENAULT_CLU_1_T_V2

  • Service 22DID 2316
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 °C
Unit
°C

In testing for 2015 to 2026.

Clutch 1 torque RENAULT_CLU_1_TQ

  • Service 22DID 2E35
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch 1 torque RENAULT_CLU_1_TQ_V2

  • Service 22DID 0010
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch 1 torque before reset RENAULT_CLU_1_TQ_BEFORE

  • Service 22DID 0050
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095
Unit
Number

In testing for 2015 to 2026.

Clutch 1 torque, desired RENAULT_CLU_1_TQ_DES

  • Service 22DID 2E35
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Clutch 1 torque, desired RENAULT_CLU_1_TQ_DES_7E1

  • Service 22DID 2306
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Clutch 1 torque, desired RENAULT_CLU_1_TQ_DES_V2

  • Service 22DID 0014
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Clutch 1 torque, requested RENAULT_CLU_1_TQ_REQ

  • Service 22DID 2E35
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Clutch 1 torque, requested RENAULT_CLU_1_TQ_REQ_V2

  • Service 22DID 000D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Clutch 1 touch point RENAULT_CLU_1_TOUCH_POINT

  • Service 21PID 33
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 mm
Unit
mm

In testing for 2015 to 2026.

Clutch 1 touch point RENAULT_CLU_1_TOUCH_POINT_7E1

  • Service 22DID 2223
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2048
Range
0 to 31.99
Unit
Raw value

In testing for 2015 to 2026.

Clutch 1 wear RENAULT_CLU_1_WEAR

  • Service 22DID 0018
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2015 to 2026.

Clutch 2 RENAULT_CLU_2

  • Service 21PID A7
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch 2 estimated torque RENAULT_CLU_2_ESTIMATED_TQ

  • Service 22DID 2313
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Clutch 2 open RENAULT_CLU_2_OPEN

  • Service 22DID 0045
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch 2 pressure RENAULT_CLU_2_P

  • Service 22DID 235E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127 bar
Unit
bar

In testing for 2015 to 2026.

Clutch 2 pressure RENAULT_CLU_2_P_7E1

  • Service 22DID 2061
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2015 to 2026.

Clutch 2 sensor power supply RENAULT_CLU_2_SENS_POWER_SUP

  • Service 22DID 2062
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Clutch 2 solenoid valve control, current RENAULT_CLU_2_SOLEN_VLV_CTRL

  • Service 22DID 2D38
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 A
Unit
A

In testing for 2015 to 2026.

Clutch 2 temperature RENAULT_CLU_2_T

  • Service 21PID A7
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 °C
Unit
°C

In testing for 2015 to 2026.

Clutch 2 temperature RENAULT_CLU_2_T_7E1

  • Service 22DID 0017
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 °C
Unit
°C

In testing for 2015 to 2026.

Clutch 2 temperature RENAULT_CLU_2_T_7E1_2

  • Service 22DID 00B6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2015 to 2026.

Clutch 2 temperature RENAULT_CLU_2_T_V2

  • Service 22DID 2317
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 °C
Unit
°C

In testing for 2015 to 2026.

Clutch 2 torque RENAULT_CLU_2_TQ

  • Service 22DID 0011
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch 2 torque before reset RENAULT_CLU_2_TQ_BEFORE

  • Service 22DID 0051
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095
Unit
Number

In testing for 2015 to 2026.

Clutch 2 torque, desired RENAULT_CLU_2_TQ_DES

  • Service 22DID 2307
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Clutch 2 torque, desired RENAULT_CLU_2_TQ_DES_V2

  • Service 22DID 0015
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Clutch 2 torque, requested RENAULT_CLU_2_TQ_REQ

  • Service 22DID 000E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2015 to 2026.

Clutch 2 touch point RENAULT_CLU_2_TOUCH_POINT

  • Service 21PID 63
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 mm
Unit
mm

In testing for 2015 to 2026.

Clutch 2 touch point RENAULT_CLU_2_TOUCH_POINT_7E1

  • Service 22DID 2223
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2048
Range
0 to 31.99
Unit
Raw value

In testing for 2015 to 2026.

Clutch 2 wear RENAULT_CLU_2_WEAR

  • Service 22DID 0019
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2015 to 2026.

Clutch contact multiplex signal RENAULT_CLU_CONTACT

  • Service 22DID 2222
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch contact multiplex signal RENAULT_CLU_CONTACT_2

  • Service 22DID 2222
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Clutch end of travel switch RENAULT_CLU_END_TRAVEL_2

  • Service 22DID 2045
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Clutch end of travel switch RENAULT_CLU_END_TRAVEL_SWITCH

  • Service 22DID 2045
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch end of travel wiring switch RENAULT_CLU_END_TRAVEL

  • Service 22DID 22B7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch information absent RENAULT_CLU_INFORMATION

  • Service 22DID 204F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Clutch information unavailable RENAULT_CLU_INFORMATION_UNAVAILABLE

  • Service 22DID 204F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Clutch motor RENAULT_CLU_MOTOR

  • Service 22DID 0040
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 A
Unit
A

In testing for 2015 to 2026.

Clutch motor 1 signal RENAULT_CLU_MOTOR_1_SIG

  • Service 22DID 2023
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Clutch motor 1 signal RENAULT_CLU_MOTOR_1_SIG_7E1

  • Service 22DID 0024
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch motor 1 signal RENAULT_CLU_MOTOR_1_SIG_V2

  • Service 22DID 0042
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2015 to 2026.

Clutch motor 2 signal RENAULT_CLU_MOTOR_2_SIG

  • Service 22DID 2033
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Clutch motor 2 signal RENAULT_CLU_MOTOR_2_SIG_7E1

  • Service 22DID 0025
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch motor 2 signal RENAULT_CLU_MOTOR_2_SIG_V2

  • Service 22DID 0043
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2015 to 2026.

Clutch pedal RENAULT_CLU_PEDAL

  • Service 22DID 2C59
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch start of travel switch RENAULT_CLU_START_TRAVEL_2

  • Service 22DID 2027
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch start of travel switch RENAULT_CLU_START_TRAVEL_SWITCH

  • Service 22DID 2027
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch start of travel switch RENAULT_CLU_START_TRAVEL_SWITCH_7E0

  • Service 22DID 2059
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Clutch start of travel wiring switch RENAULT_CLU_START_TRAVEL

  • Service 22DID 222C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch start of travel wiring switch RENAULT_CLU_START_TRAVEL_WIRING

  • Service 22DID 222C
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Clutch start of travel wiring switch RENAULT_CLU_START_TRAVEL_WIRING_V2

  • Service 22DID 2956
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch switch information RENAULT_CLU_SWITCH

  • Service 22DID 22B6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Clutch temperature RENAULT_CLU_T

  • Service 22DID 001C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Clutch torque RENAULT_CLU_TQ

  • Service 22DID 2C58
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−16384
Range
-16384 to 16383 N·m
Unit
N·m

In testing for 2015 to 2026.

Clutch very start of travel switch RENAULT_CLU_VERY_START

  • Service 22DID 28D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Converter lockup press. regulation sv, current RENAULT_CONV_LOCKUP_PRESS

  • Service 22DID 1211
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 A
Unit
A

In testing for 2015 to 2026.

Current gear engaged RENAULT_CURRENT_GEAR_ENGAGED

  • Service 22DID 208E
  • ModuleDA15 → 15
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−5
Range
-5 to 250
Unit
Number

In testing for 2015 to 2026.

Current gear position RENAULT_CURRENT_GEAR_POS

  • Service 22DID 2C46
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Current gear position RENAULT_CURRENT_GEAR_POS_7E0

  • Service 22DID 2C5B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Current gear position RENAULT_CURRENT_GEAR_POS_7E1

  • Service 22DID 2211
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Current gear position RENAULT_CURRENT_GEAR_POS_V2

  • Service 22DID 0031
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Downshift paddle RENAULT_DOWNSHIFT_PADDLE

  • Service 22DID 2D0F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Downshift paddle RENAULT_DOWNSHIFT_PADDLE_7E1

  • Service 22DID 231E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

End of clutch switch travel circuit RENAULT_END_CLU_SWITCH

  • Service 22DID 22B5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

End of clutch switch travel circuit RENAULT_END_CLU_SWITCH_TRAVEL

  • Service 22DID 22B4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Engage reverse gear RENAULT_ENGAGE_REVERSE_GEAR

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Engage reverse gear RENAULT_ENGAGE_REVERSE_GEAR_V2

  • Service 22DID 2079
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Engaged gear of gearbox input 1 RENAULT_ENGAGED_GEAR_GEARBOX_1

  • Service 22DID 2D3F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engaged gear of gearbox input 1 RENAULT_ENGAGED_GEAR_GEARBOX_INPUT_1

  • Service 22DID 2330
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2015 to 2026.

Engaged gear of gearbox input 2 RENAULT_ENGAGED_GEAR_GEARBOX_2

  • Service 22DID 2D3F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Engaged gear of gearbox input 2 RENAULT_ENGAGED_GEAR_GEARBOX_INPUT_2

  • Service 22DID 2331
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2015 to 2026.

Even shift fork, current RENAULT_EVEN_SHIFT_FORK

  • Service 22DID 2D30
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255 A
Unit
A

In testing for 2015 to 2026.

Exhaust camshaft phaser RENAULT_EXH_CAM_SHIFTER_7E0

  • Service 22DID FD27
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2015 to 2026.

Exhaust camshaft phaser set point RENAULT_EXH_CAM_SHIFTER

  • Service 22DID 224E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310
Unit
Number

In testing for 2015 to 2026.

Exhaust camshaft phaser solenoid valve duty cycle RENAULT_EXH_CAM_SHIFTER_SV

  • Service 22DID 224D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2015 to 2026.

Exhaust camshaft phaser solenoid valve programming RENAULT_EXH_CAM_SHIFTER_SV_PROGRAMMING

  • Service 22DID 2250
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Exhaust camshaft shifter sv control duty cycle RENAULT_EXH_CAM_SHIFTER_SV_2

  • Service 22DID 122F
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25256
Range
0 to 6399 %
Unit
%

In testing for 2015 to 2026.

Gear change RENAULT_GEAR_CHANGE

  • Service 22DID 0030
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Gear change paddles RENAULT_GEAR_CHANGE_PADDLES

  • Service 21PID 70
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Gear engaged RENAULT_GEAR_ENGAGED

  • Service 22DID 208E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−5
Range
-5 to 250
Unit
Number

In testing for 2015 to 2026.

Gear lever position RENAULT_GEAR_LEVER_POS

  • Service 22DID 2D4C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Gear lever position RENAULT_GEAR_LEVER_POS_2

  • Service 22DID 30BC
  • ModuleDADA → DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55
Unit
Number

In testing for 2015 to 2026.

Gear lever position RENAULT_GEAR_LEVER_POS_7E1

  • Service 22DID 20C1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Gear lever position RENAULT_GEAR_LEVER_POS_7E1_2

  • Service 22DID 232B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127
Unit
Number

In testing for 2015 to 2026.

Gear lever position RENAULT_GEAR_LEVER_POS_7E1_2_V2

  • Service 22DID 002A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Gear lever position RENAULT_GEAR_LEVER_POS_7E1_3

  • Service 22DID 1131
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Gear lever position RENAULT_GEAR_LEVER_POS_V2

  • Service 22DID 004E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Gear lever switch info. invalid RENAULT_GEAR_LEVER_SWITCH

  • Service 22DID 0029
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Gearbox acceleration sensor RENAULT_GEARBOX_ACCEL_SENS

  • Service 22DID 1216
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 %
Unit
%

In testing for 2015 to 2026.

Gearbox input 1 speed RENAULT_GEARBOX_INPUT_1_SPD

  • Service 22DID 2071
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Gearbox input 1 speed RENAULT_GEARBOX_INPUT_1_SPD_7E1

  • Service 22DID 2303
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Gearbox input 1 speed RENAULT_GEARBOX_INPUT_1_SPD_V2

  • Service 22DID 0002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Gearbox input 2 speed RENAULT_GEARBOX_INPUT_2_SPD

  • Service 21PID A7
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Gearbox input 2 speed RENAULT_GEARBOX_INPUT_2_SPD_7E1

  • Service 22DID 0003
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Gearbox input 2 speed RENAULT_GEARBOX_INPUT_2_SPD_V2

  • Service 22DID 2081
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2015 to 2026.

Gearbox oil temperature RENAULT_GEARBOX_OIL_T

  • Service 21PID A2
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2015 to 2026.

Gearbox oil temperature RENAULT_GEARBOX_OIL_T_7E1

  • Service 21PID A6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Gearbox oil temperature RENAULT_GEARBOX_OIL_T_7E1_2

  • Service 22DID 1121
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Gearbox output speed RENAULT_GEARBOX_OUTPUT_SPD

  • Service 22DID 232A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095 rpm
Unit
rpm

In testing for 2015 to 2026.

Gearbox position RENAULT_GEARBOX_POS

  • Service 22DID 002B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Gearbox ratio RENAULT_GEARBOX_RAT

  • Service 22DID 2C04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 5 to 7 of the reply, 3 bits.

Formula
val
Range
0 to 7
Unit
Number

In testing for 2015 to 2026.

Gearbox ratio RENAULT_GEARBOX_RAT_V2

  • Service 22DID 1113
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val25
Range
0 to 10.2
Unit
Number

In testing for 2015 to 2026.

Gearbox ratio RENAULT_GEARBOX_RATIO

  • Service 22DID 2C04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Gearbox ratio, target RENAULT_GEARBOX_RATIO_TGT

  • Service 22DID 2C03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Gearbox type RENAULT_GBOX_TYPE

  • Service 22DID 4B26
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Gearbox type RENAULT_GEARBOX_TYPE

  • Service 22DID 3050
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

High clutch and reverse brake sv, current RENAULT_HIGH_CLU_REVERSE

  • Service 22DID 1214
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 A
Unit
A

In testing for 2015 to 2026.

Inlet camshaft phaser ref. position RENAULT_INLET_CAM_SHIFTER

  • Service 21PID A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×38
Range
0 to 95.62 °
Unit
°

In testing for 2015 to 2026.

Inlet camshaft shifter contr0l duty cycle RENAULT_INLET_CAM_SHIFTER_2

  • Service 22DID 1138
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2015 to 2026.

Inlet camshaft shifter control OCR RENAULT_INLET_CAM_SHIFTER_V2

  • Service 22DID 2033
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2015 to 2026.

Manual gearbox gear lever position RENAULT_MANUAL_GEARBOX_GEAR

  • Service 21PID 10
  • Module74D → 76D
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Manual gearbox lever in neutral RENAULT_MANUAL_GEARBOX_LEVER

  • Service 22DID 222E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Manual gearbox lever in neutral RENAULT_MANUAL_GEARBOX_LEVER_2

  • Service 22DID 222E
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Odd shift fork, current RENAULT_ODD_SHIFT_FORK

  • Service 22DID 2D2F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255 A
Unit
A

In testing for 2015 to 2026.

Position 1 gearbox actuator RENAULT_POS_1_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 2 gearbox actuator RENAULT_POS_2_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 3 gearbox actuator RENAULT_POS_3_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 4 gearbox actuator RENAULT_POS_4_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 5 gearbox actuator RENAULT_POS_5_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 6 gearbox actuator RENAULT_POS_6_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 7 gearbox actuator RENAULT_POS_7_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 8 gearbox actuator RENAULT_POS_8_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 9 gearbox actuator RENAULT_POS_9_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 10 gearbox actuator RENAULT_POS_10_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 11 gearbox actuator RENAULT_POS_11_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 12 gearbox actuator RENAULT_POS_12_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 13 gearbox actuator RENAULT_POS_13_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Position 14 gearbox actuator RENAULT_POS_14_GEARBOX

  • Service 22DID 325D
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10000
Range
-0.0128 to 0.0127 m
Unit
m

In testing for 2015 to 2026.

Shift drum 1 RENAULT_SHIFT_DRUM_1

  • Service 22DID 00B7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2015 to 2026.

Shift drum 1 position RENAULT_SHIFT_DRUM_1_POS

  • Service 22DID 2001
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 °
Unit
°

In testing for 2015 to 2026.

Shift drum 1 position RENAULT_SHIFT_DRUM_1_POS_V2

  • Service 22DID 0064
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 A
Unit
A

In testing for 2015 to 2026.

Shift drum 1 relative position RENAULT_SHIFT_DRUM_1_REL_POS

  • Service 22DID 2002
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2015 to 2026.

Shift drum 2 RENAULT_SHIFT_DRUM_2

  • Service 22DID 00B8
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2015 to 2026.

Shift drum 2 position RENAULT_SHIFT_DRUM_2_POS

  • Service 22DID 237D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 °
Unit
°

In testing for 2015 to 2026.

Shift drum 2 position RENAULT_SHIFT_DRUM_2_POS_7E1

  • Service 22DID 2011
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 °
Unit
°

In testing for 2015 to 2026.

Shift drum 2 position RENAULT_SHIFT_DRUM_2_POS_V2

  • Service 22DID 0065
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 A
Unit
A

In testing for 2015 to 2026.

Shift drum 2 relative position RENAULT_SHIFT_DRUM_2_REL_POS

  • Service 22DID 2012
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2015 to 2026.

Shift lever control RENAULT_SHIFT_LEVER_CTRL

  • Service 22DID 2C05
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Shift lock function RENAULT_SHIFT_LOCK_FUNCTION

  • Service 22DID 00BA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Supply voltage gear selector motor 1 RENAULT_SUP_V_GEAR_SELECTOR_1

  • Service 22DID 2005
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Supply voltage gear selector motor 2 RENAULT_SUP_V_GEAR_SELECTOR_2

  • Service 22DID 2015
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2015 to 2026.

Target gear of gearbox input 1 RENAULT_TGT_GEAR_GEARBOX_1

  • Service 22DID 2135
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Target gear of gearbox input 2 RENAULT_TGT_GEAR_GEARBOX_2

  • Service 22DID 2135
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Target high clutch pressure RENAULT_TGT_HIGH_CLU_P

  • Service 22DID 1129
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 bar
Unit
bar

In testing for 2015 to 2026.

Torque used by automatic transmission converter RENAULT_TQ_USED_T_CONV

  • Service 21PID A5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 N·m
Unit
N·m

In testing for 2015 to 2026.

Transmission mode button position RENAULT_TRANS_MODE_BTN_POS

  • Service 22DID 3022
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Upshift paddle RENAULT_UPSHIFT_PADDLE

  • Service 22DID 231D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2026.

Trips

Distance at first fault RENAULT_FAULT_DIST_FIRST

  • Service 22DID 4B09
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Distance before next oil change RENAULT_DIST_BEFORE_NEXT_OIL

  • Service 22DID 2110
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Distance units RENAULT_DIST_UNITS

  • Service 22DID 0104
  • Module743 → 763
  • Every30 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Distance when fault first occurred RENAULT_DIST_FAULT_FIRST

  • Service 22DID 4B09
  • Module740 → 760
  • Every1 s
  • Testing

Bits 4 to 31 of the reply, 28 bits.

Formula
val100
Range
0 to 2684354 km
Unit
km

In testing for 2015 to 2026.

Distance when fault first occurred RENAULT_DIST_FAULT_FIRST_V2

  • Service 22DID F0D0
  • ModuleDADA → DA
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Driven distance since the last successful regeneration RENAULT_DRIVEN_DIST_SINCE

  • Service 22DID 30DB
  • ModuleDA15 → 15
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2015 to 2026.

Duration of distance button press RENAULT_DUR_DIST_BUTTON

  • Service 22DID 217D
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2015 to 2026.

Engine control module odometer RENAULT_ENG_CTRL_MODULE_ODO

  • Service 22DID 2006
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Mileage since last fault RENAULT_FAULT_DIST_LAST

  • Service 22DID 4B0A
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Odometer RENAULT_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 4B06
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val100
Range
0 to 42949672.95 km
Unit
km

In testing for 2015 to 2026.

Odometer RENAULT_ODO_2

Pelican can show this parameter as the odometer.

  • Service 22DID 2006
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Odometer RENAULT_ODO_KM

  • Service 22DID 0207
  • Module743
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Odometer RENAULT_ODO_V2

Pelican can show this parameter as the odometer.

  • Service 22DID 0207
  • Module743
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Odometer fault warning light illuminated, OBD RENAULT_OBD_ODO_FAULT_WARN

  • Service 21PID A6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2015 to 2026.

Odometer, km RENAULT_ODO_KM_7E1

  • Service 22DID 2305
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2015 to 2026.

Odometer, km RENAULT_ODO_KM_V2

  • Service 22DID 0005
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-21474836 to 21474836 km
Unit
km

In testing for 2015 to 2026.

Odometers RENAULT_ODOMETERS

  • Service 21PID 18
  • Module743 → 763
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Oil change range/current value in km RENAULT_OIL_CHANGE_RANGE

  • Service 21PID 19
  • Module743 → 763
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2015 to 2026.

Oil change range/current value in km RENAULT_OIL_CHANGE_RANGE_CURRENT_KM

  • Service 22DID 0203
  • Module743 → 763
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×64103
Range
0 to 40720 mi
Unit
mi

In testing for 2015 to 2026.

Oil change range/current value in months RENAULT_OIL_CHANGE_RANGE_CURRENT

  • Service 21PID 1A
  • Module743 → 763
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Total distance traveled in km RENAULT_TOT_DIST_TRAVELLED

  • Service 22DID 2E30
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-21474836 to 21474836 km
Unit
km

In testing for 2015 to 2026.

Total distance traveled in km RENAULT_TOT_DIST_TRAVELLED_2

  • Service 22DID 1070
  • ModuleDADA → DA
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.

Total vehicle distance RENAULT_TOT_VEH_DIST

  • Service 22DID 2006
  • ModuleDA15 → 15
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2015 to 2026.