Ram ProMaster Window Van

Parameters

The Ram ProMaster Window Van has 45 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage PROMASTER_BATT_V_ECUConfirmed

  • Service 22DID 1955
  • ModuleDA10 → 10
  • Every30 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 20 V
Unit
V

Confirmed for 2025. In testing for 2014 to 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery voltage PROMASTER_BATT_V_ECUConfirmed

  • Service 22DID 1955
  • ModuleDA10 → 10
  • Every30 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000
Range
0 to 20 V
Unit
V

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Battery voltage, BCM PROMASTER_BATT_V_BCMConfirmed

  • Service 22DID 1004
  • ModuleDA40 → 40
  • Every30 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25 V
Unit
V

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2025.

Details

Model year PROMASTER_MODEL_YEARConfirmed

  • Service 22DID F158
  • ModuleDA18 → 18
  • Every86400 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val+2000
Range
0 to 2225
Unit
Number

Confirmed for 2025. In testing for 2014 to 2024, 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2025.

Distance with water in fuel warning PROMASTER_WATER_FUEL_DISTConfirmed

  • Service 22DID 1009
  • ModuleDA10 → 10
  • Every3600 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Emissions

Forced regen state PROMASTER_FORCED_REGENConfirmed

  • Service 22DID 18EC
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Lambda downstream DPF O2 concentration PROMASTER_LAMBDA_DPF_DSConfirmed

  • Service 22DID 18ED
  • ModuleDA10 → 10
  • Every2 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 25 %
Unit
%

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Particulate filter differential pressure PROMASTER_DPF_DIFF_PRESS

  • Service 22DID 18E2
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.8
Range
-50 to 50 kPa
Unit
kPa

In testing for 2014 to 2024, 2026. Not supported for 2025.

Particulate filter flow resistance PROMASTER_DPF_FLOW_RESConfirmed

  • Service 22DID 18E8
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535
Unit
Number

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Particulate filter inlet temperature PROMASTER_DPF_INLET_T

  • Service 22DID 18DE
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 900 °C
Unit
°C

In testing for 2014 to 2024, 2026. Not supported for 2025.

Particulate filter regen interrupted count PROMASTER_REGEN_INTERRUPTEDConfirmed

  • Service 22DID 18A5
  • ModuleDA10 → 10
  • Every60 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Particulate filter regeneration interruptions, consecutive PROMASTER_REGEN_CONSEC_INTERRUPTEDConfirmed

  • Service 22DID 18AE
  • ModuleDA10 → 10
  • Every3600 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Particulate filter soot clogging level PROMASTER_DPF_SOOT_PCT

  • Service 22DID 18E4
  • ModuleDA10 → 10
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 100 %
Unit
%

In testing for 2014 to 2024, 2026. Not supported for 2025.

Total DPF regenerations started PROMASTER_REGEN_TOTALConfirmed

  • Service 22DID 18A4
  • ModuleDA10 → 10
  • Every3600 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Engine

Automatic transmission fluid temperature PROMASTER_ATF_T_4THGENConfirmed

  • Service 22DID 04FE
  • ModuleDA18 → 18
  • Every1 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2025.

Coolant temperature PROMASTER_ECT_ECUConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 1003
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 200 °C
Unit
°C

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Diesel fuel temperature PROMASTER_FUEL_TEMP

  • Service 22DID 1900
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 200 °C
Unit
°C

In testing for 2014 to 2024, 2026. Not supported for 2025.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025.

Engine operational status PROMASTER_ENGINE_STATUSConfirmed

  • Service 22DID 1002
  • ModuleDA10 → 10
  • Every30 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2014 to 2024, 2026.

M-Prop injection command PROMASTER_MPROP_CMD

  • Service 22DID 18D0
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2014 to 2024, 2026. Not supported for 2025.

Mass airflow sensor temperature PROMASTER_MAF_TEMP

  • Service 22DID 193F
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2100−40
Range
-40 to 200 °C
Unit
°C

In testing for 2014 to 2024, 2026. Not supported for 2025.

Swirl actuator command PROMASTER_SWIRL_CMDConfirmed

  • Service 22DID 189B
  • ModuleDA10 → 10
  • Every2 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-100 to 100 %
Unit
%

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Turbo boost pressure PROMASTER_BOOSTConfirmed

  • Service 22DID 195A
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.8
Range
-100 to 300 kPa
Unit
kPa

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Variable oil pump position PROMASTER_OIL_PUMPConfirmed

  • Service 22DID 194F
  • ModuleDA10 → 10
  • Every30 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. In testing for 2014 to 2024, 2026.

VGT position actual PROMASTER_VGT_ACTConfirmed

  • Service 22DID 18A0
  • ModuleDA10 → 10
  • Every2 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2014 to 2024, 2026.

VGT position commanded PROMASTER_VGT_CMDConfirmed

  • Service 22DID 189F
  • ModuleDA10 → 10
  • Every2 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Fuel

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2025.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Movement

Front left wheel speed PROMASTER_WSS_FLConfirmed

  • Service 22DID 2B1E
  • ModuleDA18 → 18
  • Every1 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 300 km/h
Unit
km/h

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Front right wheel speed PROMASTER_WSS_FRConfirmed

  • Service 22DID 2B1D
  • ModuleDA18 → 18
  • Every1 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 300 km/h
Unit
km/h

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Rear left wheel speed PROMASTER_WSS_RLConfirmed

  • Service 22DID 2B1C
  • ModuleDA18 → 18
  • Every1 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 300 km/h
Unit
km/h

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Rear right wheel speed PROMASTER_WSS_RRConfirmed

  • Service 22DID 2B1B
  • ModuleDA18 → 18
  • Every1 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 300 km/h
Unit
km/h

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2025.

Tires

Front right tire sensor id PROMASTER_TID_FRConfirmed

  • Service 22DID 0124
  • ModuleDAC7 → C7
  • Every86400 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Rear right tire sensor id PROMASTER_TID_RR

  • Service 22DID 0127
  • ModuleDAC7 → C7
  • Every86400 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2014 to 2024, 2026. Not supported for 2025.

Tire size PROMASTER_TIRE_SIZEConfirmed

  • Service 22DID 2024
  • ModuleDA18 → 18
  • Every86400 s
  • Testing for 2014 to 2024, 2026

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mm
Unit
mm

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Transmission

Current gear PROMASTER_GEAR_CURRENTConfirmed

  • Service 22DID 051A
  • ModuleDA18 → 18
  • Every500 ms
  • Testing for 2014 to 2024, 2026

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Desired gear PROMASTER_GEAR_DESIREDConfirmed

  • Service 22DID 051A
  • ModuleDA18 → 18
  • Every500 ms
  • Testing for 2014 to 2024, 2026

Bits 0 to 3 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Gear engaged PROMASTER_GEAR_ECUConfirmed

  • Service 22DID 192D
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 9
Unit
Number

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Gearbox output speed PROMASTER_GEARBOX_RPMConfirmed

  • Service 22DID 2102
  • ModuleDA18 → 18
  • Every1 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Transmission-reported torque PROMASTER_TCM_TORQUEConfirmed

  • Service 22DID 1018
  • ModuleDA18 → 18
  • Every2 s
  • Testing for 2014 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val−500
Range
-500 to 1000 N·m
Unit
N·m

Confirmed for 2025. In testing for 2014 to 2024, 2026.

Trips

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2025.