Parameters
The Ram 1500 has 299 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Battery temperature 1500_BAT_T
- Service 21
PID 23 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Battery voltage 1500_BATT_V_ECU
- Service 22
DID 1955 - Module
DA10 → 10 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 20 V
- Unit
- V
In testing for 2026. Not supported for 2025.
Battery voltage, BCM 1500_BATT_V_BCMConfirmed
- Service 22
DID 1004 - Module
DA40 → 40 - Every
30 s - Testing for 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25 V
- Unit
- V
Confirmed for 2025. In testing for 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Climate
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2017.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2016 to 2026. Supported for 2012, 2014 to 2015.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2016 to 2026.
Brake booster pressure 1500_BRAKE_BOOSTER_PConfirmed
- Service 22
DID 0944 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 kPa
- Unit
- kPa
0x1946 = 6470 → = 64.7 kPa
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Relative throttle position TP_RSAE J1979Confirmed
Relative or 'learned' throttle position.
- Service 01
PID 45 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2016 to 2022, 2024 to 2026. Supported for 2023.
Steering wheel angle 1500_STEER_ANGLEConfirmed
- Service 22
DID 0885 - Module
DA30 → 30 - Every
100 ms - Testing for 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -720 to 720 °
- Unit
- °
Confirmed for 2025. In testing for 2026.
Pedals
Accelerator pedal position (relative) APP_RSAE J1979Confirmed
- Service 01
PID 5A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025.
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2016 to 2022, 2024 to 2025. Supported for 2023, 2026.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2016 to 2022, 2024 to 2025. Supported for 2023.
Details
Model year 1500_MODEL_YEARConfirmed
- Service 22
DID F158 - Module
DA18 → 18 - Every
86400 s - Testing for 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2225
- Unit
- Number
Confirmed for 2025. In testing for 2026.
Doors
Driver door open 1500_DRIVER_DOOR_OPENConfirmed
- Service 22
DID 0302 - Module
DAC7 → C7 - Every
1 s - Testing for 2026
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2026.
Passenger door open 1500_PASSENGER_DOOR_OPENConfirmed
- Service 22
DID 0302 - Module
DAC7 → C7 - Every
1 s - Testing for 2026
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2026.
Rear left door open 1500_RLD_OPENConfirmed
- Service 22
DID 0302 - Module
DAC7 → C7 - Every
1 s - Testing for 2026
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2026.
Rear right door open 1500_RRD_OPENConfirmed
- Service 22
DID 0302 - Module
DAC7 → C7 - Every
1 s - Testing for 2026
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2026.
Trunk open 1500_TRUNK_OPENConfirmed
- Service 22
DID 0302 - Module
DAC7 → C7 - Every
1 s - Testing for 2026
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2026.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2012 to 2013, 2015 to 2026. Supported for 2014.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2013, 2016, 2018 to 2026. Supported for 2012, 2014 to 2015, 2017.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2013, 2016, 2018 to 2026. Supported for 2012, 2014 to 2015, 2017.
Status
A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Catalyst monitoring CAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
EGR system monitoring EGR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
EGR system monitoring completed EGR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Evaporative system monitoring EVAP_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Heated catalyst monitoring HCAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Misfire monitoring completed MIS_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Oxygen sensor monitoring O2S_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Secondary air system monitoring AIR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Misfire monitoring enabled MIS_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2019 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017 to 2018, 2022 to 2023.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Engine
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2012 to 2013, 2015 to 2026.
Actual engine torque TQ_ACTSAE J1979Confirmed
- Service 01
PID 62 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2019 to 2026. Supported for 2017.
Air conditioning high side pressure 1500_AC_HIGH_SIDE_P
- Service 21
PID A7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 1191 psi
- Unit
- psi
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Air conditioning high side pressure 1500_AC_HIGH_SIDE_P_2Confirmed
- Service 22
DID 0329 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 3570 kPa
- Unit
- kPa
0x26 = 38 → = 532 kPa
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2017, 2025 to 2026. Supported for 2019 to 2023.
Ambient air temperature 1500_AAT
- Service 21
PID 23 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Ambient temperature 1500_AAT_2Confirmed
- Service 22
DID 0127 - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -83 to 376 °F
- Unit
- °F
0x48 = 72 → = 46.6 °F
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
AT main cylinder pressure 1500_MAIN_CYL_PConfirmed
- Service 22
DID 5034 - Module
7E1 → 7E9 - Every
1 s - Testing for 2009 to 2012, 2014, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513 bar
- Unit
- bar
0x0000 = 0 → = -40 bar
Confirmed for 2013, 2015 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024.
Automatic transmission fluid temperature 1500_ATF_T_3RDGEN
- Service 21
PID 18 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 983.9843 °F
- Unit
- °F
In testing for 2009 to 2012, 2014. Not supported for 2013, 2015 to 2025.
Automatic transmission fluid temperature 1500_ATF_T_3RDGEN_V2
- Service 21
PID 5C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Automatic transmission fluid temperature 1500_ATF_T_4THGENConfirmed
- Service 22
DID 04FE - Module
DA18 → 18 - Every
1 s - Testing for 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025. In testing for 2026.
Barometric pressure 1500_BAROMETRIC_PConfirmed
- Service 22
DID 0109 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kPa
- Unit
- kPa
0x01F3 = 499 → = 99.8 kPa
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Boost pressure sensor A BP_A_ACTSAE J1979Confirmed
Actual turbocharger/supercharger A boost pressure.
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2025 to 2026.
Boost pressure sensor B BP_B_ACTSAE J1979Confirmed
Actual turbocharger/supercharger B boost pressure.
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2025 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012 to 2013, 2015 to 2026. Supported for 2014.
Cam crank difference 1500_CAM_CRANK_DIFF
- Service 22
DID 059E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Catalyst modeled temperature 1500_CAT_MODEL_TConfirmed
- Service 22
DID 012B - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 °C
- Unit
- °C
0x0216 = 534 → 534 °C
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed
- Service 01
PID 3D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Commanded boost pressure A BP_A_CMDSAE J1979Confirmed
Turbocharger/supercharger A commanded boost pressure.
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2025 to 2026.
Commanded boost pressure B BP_B_CMDSAE J1979Confirmed
Turbocharger/supercharger B commanded boost pressure.
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2025 to 2026.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025 to 2026. Supported for 2019, 2021 to 2023.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2012 to 2013, 2015 to 2016, 2018 to 2026. Supported for 2017.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012 to 2013, 2016, 2018 to 2026.
Coolant temperature 1500_ECT_ECU
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 1003 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 200 °C
- Unit
- °C
In testing for 2026. Not supported for 2025.
EGR error EGR_ERRSAE J1979Confirmed
- Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2025 to 2026. Supported for 2019, 2021 to 2023.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2012 to 2013, 2015 to 2026. Supported for 2014.
Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed
- Service 01
PID 8E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2019 to 2026.
Engine oil pressure 1500_EOPConfirmed
- Service 22
DID 022A - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 147.8999 psi
- Unit
- psi
0x35 = 53 → = 30.74 psi
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Engine oil temperature 1500_EOT_212DConfirmed
Pelican can show this parameter as the engine oil temperature.
- Service 21
PID 2D - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -83 to 376 °F
- Unit
- °F
0xA2 = 162 → = 208.6 °F
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Engine oil temperature 1500_EOT_21D2Confirmed
- Service 21
PID D2 - Module
7E0 → 7E8 - Every
5 s - Testing for 2020, 2024 to 2026
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -64 to 191 °C
- Unit
- °C
Confirmed for 2019, 2021 to 2023. In testing for 2020, 2024. Not supported for 2013, 2016 to 2017.
Engine oil temperature EOTSAE J1979Confirmed
Pelican can show this parameter as the engine oil temperature.
- Service 01
PID 5C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025 to 2026. Supported for 2017, 2020 to 2023.
Engine operational status 1500_ENGINE_STATUSConfirmed
- Service 22
DID 1002 - Module
DA10 → 10 - Every
30 s - Testing for 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2026.
Engine reference torque TQ_REFSAE J1979Confirmed
- Service 01
PID 63 - Module
7E0 → 7E8 - Every
86400 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2019 to 2026. Supported for 2017.
Engine RPM 1500_RPMConfirmed
- Service 22
DID 1000 - Module
DA10 → 10 - Every
1 s - Testing for 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 rpm
- Unit
- rpm
Confirmed for 2025. In testing for 2026.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2012 to 2013, 2015 to 2026. Supported for 2014.
Evap system vapor pressure EVAP_VPSAE J1979Confirmed
The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Service 01
PID 32 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191.75 kPa
- Unit
- kPa
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Exhaust camshaft 1 to crankshaft offset 1500_EXH_CAM_1_OFFSET
- Service 22
DID 061B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Exhaust Gas Recirculation Temp Sensor A (Bank 1, Sensor 1) EGRTASAE J1979Confirmed
- Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025 to 2026. Supported for 2019.
Exhaust Gas Recirculation Temp Sensor B (Bank 2, Sensor 1) EGRTBSAE J1979Confirmed
- Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025 to 2026. Supported for 2019.
Exhaust Gas Recirculation Temp Sensor C (Bank 1, Sensor 2) EGRTCSAE J1979Confirmed
- Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025 to 2026. Supported for 2019.
Exhaust Gas Recirculation Temp Sensor D (Bank 2, Sensor 2) EGRTDSAE J1979Confirmed
- Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025 to 2026. Supported for 2019.
Fuel pressure FPSAE J1979Confirmed
- Service 01
PID 0A - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 765 kPa
- Unit
- kPa
Confirmed for 2013, 2016, 2018 to 2020, 2023, 2025 to 2026. Supported for 2015, 2017, 2021 to 2022.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2025 to 2026. Supported for 2020 to 2023.
Fuel rail pressure commanded 1500_RAIL_PRESS_CMD
- Service 22
DID 1946 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3000 bar
- Unit
- bar
In testing for 2026. Not supported for 2025.
Fuel rail pressure measured 1500_RAIL_PRESS
- Service 22
DID 1947 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3000 bar
- Unit
- bar
In testing for 2026. Not supported for 2025.
IAT post-intercooler 1500_IAT_TURBO
- Service 22
DID 1935 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 200 °C
- Unit
- °C
In testing for 2026. Not supported for 2025.
Injector pulse width, cylinder 1 1500_INJ_WIDTH_CYL_1Confirmed
- Service 22
DID 0234 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 ms
- Unit
- ms
0x00000530 = 1328 → = 1.328 ms
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Injector pulse width, cylinder 2 1500_INJ_WIDTH_CYL_2Confirmed
- Service 22
DID 0235 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 ms
- Unit
- ms
0x00000000 = 0 → = 0 ms
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Injector pulse width, cylinder 3 1500_INJ_WIDTH_CYL_3Confirmed
- Service 22
DID 0236 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 ms
- Unit
- ms
0x00000568 = 1384 → = 1.384 ms
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Injector pulse width, cylinder 4 1500_INJ_WIDTH_CYL_4Confirmed
- Service 22
DID 0237 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 ms
- Unit
- ms
0x00000548 = 1352 → = 1.352 ms
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Intake air temperature IATSAE J1979Confirmed
- Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026.
Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026.
Intake air temperature, bank 1, sensor 3 IAT_13SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026.
Intake air temperature, bank 2, sensor 2 IAT_22SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025 to 2026. Supported for 2023.
Intake camshaft 1 to crankshaft offset 1500_INT_CAM_1_OFFSETConfirmed
- Service 22
DID 06C2 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Intake manifold air pressure 1500_MAPConfirmed
- Service 22
DID 0174 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kPa
- Unit
- kPa
0x00B0 = 176 → = 35.2 kPa
Confirmed for 2013, 2015 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024.
Intake manifold air temperature 1500_IAT_01FFConfirmed
- Service 22
DID 01FF - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -64 to 191 °C
- Unit
- °C
0x5A = 90 → = 26 °C
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Intake manifold air temperature 1500_IAT_70B8
- Service 22
DID 70B8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 1260.2976 °C
- Unit
- °C
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Knock sensor 1 1500_KNOCK_SENS_1Confirmed
- Service 22
DID 01A9 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Knock sensor 2 1500_KNOCK_SENS_2Confirmed
- Service 22
DID 01AA - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Line pressure 1500_LINE_P
- Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 psi
- Unit
- psi
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Line pressure duty cycle 1500_LINE_P_DUTY
- Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed
- Service 01
PID 09 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed
- Service 01
PID 56 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2025 to 2026.
Long term secondary O2 sensor fuel trim (bank 2) LGSO2FT2SAE J1979Confirmed
- Service 01
PID 58 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2025 to 2026.
Low side coolant temperature 1500_LOW_SIDE_ECTConfirmed
- Service 22
DID 12C9 - Module
7E0 → 7E8 - Every
5 s - Testing for 2020, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 191 °C
- Unit
- °C
Confirmed for 2019, 2021 to 2023. In testing for 2020, 2024. Supported for 2016. Not supported for 2013, 2017.
Mass airflow sensor temperature 1500_MAF_TEMP
- Service 22
DID 193F - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 200 °C
- Unit
- °C
In testing for 2026. Not supported for 2025.
Multi-displacement system active 1500_MDS_ACTIVEConfirmed
- Service 22
DID 0ECA - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Power take off (PTO) status PTO_STATSAE J1979Confirmed
- Service 01
PID 1E - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2012 to 2013. Supported for 2019.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 08 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Short term knock retard 1500_SHORT_TERM_KNOCK
- Service 22
DID 01AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 °
- Unit
- °
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Throttle inlet air temperature filtered 1500_THROTTLE_INLET_AIR_TConfirmed
- Service 22
DID 14B1 - Module
7E0 → 7E8 - Every
5 s - Testing for 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -64 to 191 °C
- Unit
- °C
0x54 = 84 → = 20 °C
Confirmed for 2019, 2021 to 2023. In testing for 2020, 2024. Not supported for 2013, 2016 to 2017.
Throttle inlet air temperature raw 1500_THROTTLE_INLET_AIR_T_RAWConfirmed
- Service 22
DID 14B3 - Module
7E0 → 7E8 - Every
5 s - Testing for 2020, 2024 to 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -64 to 191 °C
- Unit
- °C
Confirmed for 2019, 2021 to 2023. In testing for 2020, 2024. Not supported for 2013, 2016 to 2017.
Throttle inlet pressure 1500_THROTTLE_INLET_PConfirmed
- Service 22
DID 1247 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 409.5937 kPa
- Unit
- kPa
0x3E60 = 15968 → = 99.8 kPa
Confirmed for 2019, 2021 to 2023. In testing for 2020, 2024. Supported for 2016. Not supported for 2013, 2017.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Turbo boost pressure 1500_BOOST
- Service 22
DID 195A - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -100 to 300 kPa
- Unit
- kPa
In testing for 2026. Not supported for 2025.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2013, 2016, 2018 to 2026. Supported for 2017.
Variable oil pump position 1500_OIL_PUMP
- Service 22
DID 194F - Module
DA10 → 10 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2026. Not supported for 2025.
Variable valve timing oil pressure 1500_VARIABLE_VLV_TIM_OIL_PConfirmed
- Service 22
DID 069E - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
0x35 = 53 → = 212 kPa
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Variable valve timing oil temperature 1500_VARIABLE_VLV_TIM_OIL_TConfirmed
- Service 22
DID 069F - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 191 °C
- Unit
- °C
0x7E = 126 → = 62 °C
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Wastegate position sensor 1500_WASTEGATE_POS_SENSConfirmed
- Service 22
DID 1F59 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 319.8107 V
- Unit
- V
0x0000 = 0 → = 0 V
Confirmed for 2019, 2021 to 2023. In testing for 2020, 2024. Not supported for 2013, 2016 to 2017.
Internal
Boost bressure A control status BP_ASAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 78 to 79 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | BP_A_OL | Open loop |
2 | BP_A_CL | Closed loop |
3 | BP_A_FAULT | Fault |
Confirmed for 2025 to 2026.
Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026.
Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026.
Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026.
Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026.
Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026.
Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026.
EGR Temperature Sensor A (Bank 1, Sensor 1) supported? EGRTA_SUPSAE J1979Confirmed
- Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor A (Bank 1, Sensor 1) Wide Range supported? EGRTA_WR_SUPSAE J1979Confirmed
- Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor B (Bank 2, Sensor 1) supported? EGRTB_SUPSAE J1979Confirmed
- Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor B (Bank 2, Sensor 1) Wide Range supported? EGRTB_WR_SUPSAE J1979Confirmed
- Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor C (Bank 1, Sensor 2) supported? EGRTC_SUPSAE J1979Confirmed
- Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor C (Bank 1, Sensor 2) Wide Range supported? EGRTC_WR_SUPSAE J1979Confirmed
- Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor D (Bank 2, Sensor 2) supported? EGRTD_SUPSAE J1979Confirmed
- Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
EGR Temperature Sensor D (Bank 2, Sensor 2) Wide Range supported? EGRTD_WR_SUPSAE J1979Confirmed
- Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025 to 2026. Supported for 2019.
IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2025. Supported for 2017, 2020 to 2023.
Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 kPa
- Unit
- kPa
Confirmed for 2025. Supported for 2017, 2020 to 2023.
Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2025. Supported for 2017, 2020 to 2023.
Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2025. Supported for 2017, 2020 to 2023.
OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012, 2016, 2018 to 2022, 2024 to 2025. Supported for 2013 to 2015, 2017, 2023, 2026.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2023, 2025 to 2026. Supported for 2019 to 2022.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2017. Supported for 2019.
O2S Output Voltage Bank 1, Sensor 1 O2S11SAE J1979Confirmed
- Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2016, 2018 to 2022, 2024. Supported for 2012 to 2015, 2017, 2023, 2025.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2016, 2018 to 2022, 2024 to 2025. Supported for 2012 to 2015, 2017, 2023, 2026.
O2S Output Voltage Bank 2, Sensor 1 O2S21SAE J1979Confirmed
- Service 01
PID 18 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2018 to 2019. Supported for 2012 to 2017, 2020 to 2024.
O2S Output Voltage Bank 2, Sensor 2 O2S22SAE J1979Confirmed
- Service 01
PID 19 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2018 to 2019, 2025. Supported for 2012 to 2017, 2020 to 2024, 2026.
SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed
- Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2016, 2018 to 2022, 2024. Supported for 2012 to 2015, 2017, 2023, 2025.
SHRTFT associated with O2S21 SHRTFT21SAE J1979Confirmed
- Service 01
PID 18 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2018 to 2019. Supported for 2012 to 2017, 2020 to 2024.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2023, 2025 to 2026. Supported for 2019 to 2022.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2017. Supported for 2019.
Fuel
Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2023, 2025 to 2026.
Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2023, 2025 to 2026.
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2019 to 2021, 2023 to 2026.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L/h
- Unit
- L/h
Confirmed for 2017, 2022 to 2024.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2019 to 2021, 2023 to 2026.
Fuel level 1500_FLI
- Service 21
PID A8 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Fuel level 1500_FLI_7E0Confirmed
- Service 22
DID 040F - Module
7E0 → 7E8 - Every
30 s - Testing for 2009 to 2012, 2014, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -18638 to 18637 L
- Unit
- L
0x0028 = 40 → = 22.752 L
Confirmed for 2013, 2015 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024.
Fuel level average 1500_FLI_AVG
- Service 22
DID A043 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Fuel level input 1500_FLI_INPUTConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 0227 - Module
7E0 → 7E8 - Every
30 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x7B = 123 → = 48.235294 %
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Fuel rail pressure 1500_FUEL_RAIL_P_06F3Confirmed
- Service 22
DID 06F3 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2012, 2014, 2017, 2019 to 2021, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535
- Unit
- Raw value
0x0000 = 0 → = 0
Confirmed for 2013, 2015 to 2016, 2018, 2022 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017, 2019, 2021.
Fuel Rail Pressure A FRP_ASAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2023, 2025 to 2026.
Fuel Rail Pressure B FRP_BSAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2023, 2025 to 2026.
Fuel Rail Temperature A FRT_ASAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026.
Fuel Rail Temperature B FRT_BSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025 to 2026.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2012 to 2013, 2016, 2018 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017, 2022 to 2023.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2012 to 2013, 2016, 2018 to 2021, 2024 to 2026. Supported for 2014 to 2015, 2017, 2022 to 2023.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012 to 2013, 2015 to 2026. Supported for 2014.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2019 to 2021, 2023 to 2026.
Internal
Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023, 2025 to 2026.
Movement
Front left wheel speed 1500_FL_VSS
- Service 22
DID 2962 - Module
DA30 → 30 - Every
100 ms - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 km/h
- Unit
- km/h
In testing for 2026. Not supported for 2025.
Front left wheel speed 1500_WSS_FL
- Service 22
DID 2B1E - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 km/h
- Unit
- km/h
In testing for 2026. Not supported for 2025.
Front right wheel speed 1500_FR_VSS
- Service 22
DID 2962 - Module
DA30 → 30 - Every
100 ms - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 km/h
- Unit
- km/h
In testing for 2026. Not supported for 2025.
Front right wheel speed 1500_WSS_FR
- Service 22
DID 2B1D - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 km/h
- Unit
- km/h
In testing for 2026. Not supported for 2025.
Output shaft speed 1500_OUTPUT_SHFT_SPD
- Service 21
PID CA - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 8191 rpm
- Unit
- rpm
In testing for 2009 to 2012, 2014, 2020, 2024. Supported for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. Not supported for 2017.
Radiator fan speed 1500_RADIATOR_FAN_SPDConfirmed
- Service 21
PID B3 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 132600 rpm
- Unit
- rpm
0x00 = 0 → = 0 rpm
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Rear left wheel speed 1500_RL_VSS
- Service 22
DID 2962 - Module
DA30 → 30 - Every
100 ms - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 km/h
- Unit
- km/h
In testing for 2026. Not supported for 2025.
Rear left wheel speed 1500_WSS_RL
- Service 22
DID 2B1C - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 km/h
- Unit
- km/h
In testing for 2026. Not supported for 2025.
Rear right wheel speed 1500_RR_VSS
- Service 22
DID 2962 - Module
DA30 → 30 - Every
100 ms - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 km/h
- Unit
- km/h
In testing for 2026. Not supported for 2025.
Rear right wheel speed 1500_WSS_RR
- Service 22
DID 2B1B - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 km/h
- Unit
- km/h
In testing for 2026. Not supported for 2025.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2012 to 2013, 2015 to 2026. Supported for 2014.
Vehicle speed, engine computer 1500_VSS_ECU
Pelican can show this parameter as the speed.
- Service 22
DID 190B - Module
DA10 → 10 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 km/h
- Unit
- km/h
In testing for 2026. Not supported for 2025.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2012 to 2013, 2016, 2018 to 2026. Supported for 2014 to 2015, 2017.
Orientation
Lateral acceleration 1500_LAT_G
- Service 22
DID 2962 - Module
DA30 → 30 - Every
100 ms - Testing
Bits 4 to 15 of the reply, 12 bits.
- Formula
- Range
- -40.94 to 40.94 m/s²
- Unit
- m/s²
In testing for 2026. Not supported for 2025.
Longitudinal acceleration 1500_LNG_G
- Service 22
DID 2962 - Module
DA30 → 30 - Every
100 ms - Testing
Bits 20 to 31 of the reply, 12 bits.
- Formula
- Range
- -40.94 to 40.94 m/s²
- Unit
- m/s²
In testing for 2026. Not supported for 2025.
Tires
Front left tire pressure 1500_TP_FLConfirmed
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID A077 - Module
742 → 4C2 - Every
5 s - Testing for 2009 to 2012, 2014
Example reply from a 2017 Ram 1500.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 psi
- Unit
- psi
0x26 = 38 → 38 psi
Confirmed for 2013, 2015 to 2017. In testing for 2009 to 2011, 2014. Not supported for 2012, 2018 to 2021, 2024 to 2026.
Front left tire pressure 1500_TP_FL_2
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 013C - Module
DAC7 → C7 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2026. Not supported for 2025.
Front left tire pressure invalid? 1500_TP_FL_INVALIDConfirmed
- Service 22
DID 012F - Module
DAC7 → C7 - Every
5 s - Testing for 2026
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2026.
Front left tire sensor id 1500_TID_FLConfirmed
- Service 22
DID 0123 - Module
DAC7 → C7 - Every
86400 s - Testing for 2026
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
Confirmed for 2025. In testing for 2026.
Front left tire temperature 1500_TT_FL
Pelican can show this parameter as the front left tire temperature.
- Service 22
DID 013C - Module
DAC7 → C7 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2026. Not supported for 2025.
Front left wheel speed 1500_FL_WHL_SPDConfirmed
- Service 22
DID 1737 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.9843 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2019, 2021 to 2023. In testing for 2020, 2024. Supported for 2016. Not supported for 2013, 2017.
Front right tire pressure 1500_TP_FRConfirmed
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID A077 - Module
742 → 4C2 - Every
5 s - Testing for 2009 to 2012, 2014
Example reply from a 2017 Ram 1500.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 psi
- Unit
- psi
0x25 = 37 → 37 psi
Confirmed for 2013, 2015 to 2017. In testing for 2009 to 2011, 2014. Not supported for 2012, 2018 to 2021, 2024 to 2026.
Front right tire pressure 1500_TP_FR_2
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 013D - Module
DAC7 → C7 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2026. Not supported for 2025.
Front right tire pressure invalid? 1500_TP_FR_INVALIDConfirmed
- Service 22
DID 012F - Module
DAC7 → C7 - Every
5 s - Testing for 2026
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2026.
Front right tire sensor id 1500_TID_FRConfirmed
- Service 22
DID 0124 - Module
DAC7 → C7 - Every
86400 s - Testing for 2026
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
Confirmed for 2025. In testing for 2026.
Front right tire temperature 1500_TT_FR
Pelican can show this parameter as the front right tire temperature.
- Service 22
DID 013D - Module
DAC7 → C7 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2026. Not supported for 2025.
Front right wheel speed 1500_FR_WHL_SPDConfirmed
- Service 22
DID 1738 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.9843 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2019, 2021 to 2023. In testing for 2020, 2024. Supported for 2016. Not supported for 2013, 2017.
Rear left tire pressure 1500_TP_RLConfirmed
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID A077 - Module
742 → 4C2 - Every
5 s - Testing for 2009 to 2012, 2014
Example reply from a 2017 Ram 1500.
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 psi
- Unit
- psi
0x26 = 38 → 38 psi
Confirmed for 2013, 2015 to 2017. In testing for 2009 to 2011, 2014. Not supported for 2012, 2018 to 2021, 2024 to 2026.
Rear left tire pressure 1500_TP_RL_2
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 013E - Module
DAC7 → C7 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2026. Not supported for 2025.
Rear left tire pressure invalid? 1500_TP_RL_INVALIDConfirmed
- Service 22
DID 012F - Module
DAC7 → C7 - Every
5 s - Testing for 2026
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2026.
Rear left tire sensor id 1500_TID_RLConfirmed
- Service 22
DID 0125 - Module
DAC7 → C7 - Every
86400 s - Testing for 2026
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
Confirmed for 2025. In testing for 2026.
Rear left tire temperature 1500_TT_RL
Pelican can show this parameter as the rear left tire temperature.
- Service 22
DID 013E - Module
DAC7 → C7 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2026. Not supported for 2025.
Rear left wheel speed 1500_RL_WHL_SPDConfirmed
- Service 22
DID 1739 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.9843 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2019, 2021 to 2023. In testing for 2020, 2024. Supported for 2016. Not supported for 2013, 2017.
Rear right tire pressure 1500_TP_RRConfirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID A077 - Module
742 → 4C2 - Every
5 s - Testing for 2009 to 2012, 2014
Example reply from a 2017 Ram 1500.
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 psi
- Unit
- psi
0x26 = 38 → 38 psi
Confirmed for 2013, 2015 to 2017. In testing for 2009 to 2011, 2014. Not supported for 2012, 2018 to 2021, 2024 to 2026.
Rear right tire pressure 1500_TP_RR_2
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 013F - Module
DAC7 → C7 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2026. Not supported for 2025.
Rear right tire pressure invalid? 1500_TP_RR_INVALIDConfirmed
- Service 22
DID 012F - Module
DAC7 → C7 - Every
5 s - Testing for 2026
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2026.
Rear right tire sensor id 1500_TID_RRConfirmed
- Service 22
DID 0127 - Module
DAC7 → C7 - Every
86400 s - Testing for 2026
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
Confirmed for 2025. In testing for 2026.
Rear right tire temperature 1500_TT_RR
Pelican can show this parameter as the rear right tire temperature.
- Service 22
DID 013F - Module
DAC7 → C7 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2026. Not supported for 2025.
Rear right wheel speed 1500_RR_WHL_SPDConfirmed
- Service 22
DID 173A - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.9843 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2019, 2021 to 2023. In testing for 2020, 2024. Supported for 2016. Not supported for 2013, 2017.
Tire size 1500_TIRE_SIZEConfirmed
- Service 22
DID 2024 - Module
DA18 → 18 - Every
86400 s - Testing for 2026
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mm
- Unit
- mm
Confirmed for 2025. In testing for 2026.
Transmission
Current gear 1500_CURRENT_GEAR
- Service 22
DID 3C22 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5
- Unit
- Number
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Current gear 1500_GEARConfirmed
The automatic transmission gear.
- Service 22
DID 5503 - Module
7E1 → 7E9 - Every
1 s - Testing for 2009 to 2012, 2014
Example reply from a 2024 Ram 1500.
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
0b0000 = 0 → NEUTRAL
| Raw value | State | Meaning |
|---|---|---|
0 | NEUTRAL | Neutral |
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
9 | 9 | Ninth gear |
10 | 10 | Tenth gear |
11 | REAR | Rear |
13 | PARK | Park |
Confirmed for 2013, 2015 to 2024. In testing for 2009 to 2011, 2014. Not supported for 2012, 2025 to 2026.
Current gear 1500_GEAR_CURRENTConfirmed
- Service 22
DID 051A - Module
DA18 → 18 - Every
500 ms - Testing for 2026
Bits 4 to 7 of the reply, 4 bits.
- Formula
- Range
- 0 to 15
- Unit
- Number
Confirmed for 2025. In testing for 2026.
Desired gear 1500_GEAR_DESIREDConfirmed
- Service 22
DID 051A - Module
DA18 → 18 - Every
500 ms - Testing for 2026
Bits 0 to 3 of the reply, 4 bits.
- Formula
- Range
- 0 to 15
- Unit
- Number
Confirmed for 2025. In testing for 2026.
Gear engaged 1500_GEAR_ECU
- Service 22
DID 192D - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 9
- Unit
- Number
In testing for 2026. Not supported for 2025.
Gearbox output speed 1500_GEARBOX_RPM
- Service 22
DID 2102 - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 rpm
- Unit
- rpm
In testing for 2026. Not supported for 2025.
Target gear 1500_GEAR_TARGETConfirmed
The target gear.
- Service 22
DID 5504 - Module
7E1 → 7E9 - Every
1 s - Testing for 2009 to 2012, 2014
Example reply from a 2024 Ram 1500.
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
0b0001 = 1 → 1
| Raw value | State | Meaning |
|---|---|---|
0 | NEUTRAL | Neutral |
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
9 | 9 | Ninth gear |
10 | 10 | Tenth gear |
11 | REAR | Rear |
13 | PARK | Park |
Confirmed for 2013, 2015 to 2024. In testing for 2009 to 2011, 2014. Not supported for 2012, 2025 to 2026.
Torque converter lock status 1500_TQ_CONV_LOCK
- Service 22
DID B09B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Torque converter slip, variant 1 1500_TQ_CONV_SLIP_VAR_1
- Service 22
DID B028 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -460 to 460 rpm
- Unit
- rpm
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Torque converter slip, variant 2 1500_TQ_CONV_SLIP_VAR_2
- Service 22
DID A001 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission fluid temperature 1500_ATF_TConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 04FE - Module
7E1 → 7E9 - Every
1 s - Testing for 2009 to 2012, 2014
Example reply from a 2024 Ram 1500.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -30 to 300 °F
- Unit
- °F
0x26 = 38 → = 28.4 °F
Confirmed for 2013, 2015 to 2024. In testing for 2009 to 2011, 2014. Not supported for 2012, 2025 to 2026.
Transmission fluid temperature 1500_ATF_T_08DF
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 08DF - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission fluid temperature 1500_ATF_T_7E1
- Service 21
PID 72 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission fluid temperature 1500_ATF_T_7E1_7E1Confirmed
- Service 22
DID 5043 - Module
7E1 → 7E9 - Every
5 s - Testing for 2009 to 2012, 2014, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x66 = 102 → = 62 °C
Confirmed for 2013, 2015 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024.
Transmission fluid temperature v.2 1500_ATF_T_V_2
- Service 21
PID 18 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 2009 to 2012, 2014. Not supported for 2013, 2015 to 2025.
Transmission fluid temperature, variant 1 1500_ATF_T_VAR_1
- Service 22
DID B010 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission fluid temperature, variant 2 1500_ATF_T_VAR_2
- Service 22
DID A002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission fluid temperature, variant 3 1500_ATF_T_2130
- Service 21
PID 30 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission gear, actual 1500_GEAR_7E0
- Service 22
DID A0A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission gear, commanded 1500_GEAR_CMD
- Service 22
DID A09F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission oil temperature 1500_TOT
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID 18 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 512 °F
- Unit
- °F
In testing for 2026. Not supported for 2025.
Transmission reported torque 1500_TCM_TORQUEConfirmed
- Service 22
DID 1018 - Module
DA18 → 18 - Every
2 s - Testing for 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -500 to 1000 N·m
- Unit
- N·m
Confirmed for 2025. In testing for 2026.
Transmission sump temperature 1500_TRANS_SUMP_T
- Service 22
DID A0A3 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 921 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission sump temperature 1500_TRANS_SUMP_T_7E1
- Service 21
PID 3A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission sump temperature, variant 1 1500_TRANS_SUMP_T_VAR_1
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission sump temperature, variant 2 1500_TRANS_SUMP_T_VAR_2
- Service 21
PID CA - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Supported for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. Not supported for 2017.
Transmission temperature, variant 2 1500_TRANS_T_VAR_2
- Service 21
PID 0A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission torque converter temperature 1500_TRANS_TQ_CONV_T
- Service 22
DID A0A4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1843 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission torque converter temperature, variant 1 1500_TRANS_TQ_CONV_T_VAR_1
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 1875 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2019, 2021 to 2023.
Transmission torque converter temperature, variant 2 1500_TRANS_TQ_CONV_T_VAR_2
- Service 21
PID CA - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 1875 °F
- Unit
- °F
In testing for 2009 to 2012, 2014, 2020, 2024. Supported for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. Not supported for 2017.
Trips
Odometer 1500_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 043B - Module
7E0 → 7E8 - Every
5 s - Testing for 2009 to 2012, 2014, 2017, 2020, 2024 to 2026
Example reply from a 2023 Ram 1500.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 536862.72 mi
- Unit
- mi
0x0F3B = 3899 → = 31,940.608 mi
Confirmed for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2017.
Odometer 1500_ODO_03BCConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 03BC - Module
7E0 → 7E8 - Every
30 s - Testing for 2009 to 2016, 2018 to 2026
Example reply from a 2017 Ram 1500.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
0x098DF7F8 = 160299000 → = 160,299 km
Confirmed for 2017. In testing for 2009 to 2012, 2014, 2020, 2024. Not supported for 2013, 2015 to 2016, 2018 to 2019, 2021 to 2023.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2019 to 2026.