Parameters
The Porsche Macan Electric has 84 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery adapted capacity MACANEV_AUX_BAT_CAPConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 Ah
- Unit
- Ah
0x44 = 68 → 68 Ah
Confirmed for 2024 to 2025. In testing for 2026.
12V battery aging by capacity MACANEV_AUX_BAT_AGE_CAPConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 160 to 167 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x59 = 89 → 89 %
Confirmed for 2024 to 2025. In testing for 2026.
12V battery aging by power MACANEV_AUX_BAT_AGE_POWConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x59 = 89 → 89 %
Confirmed for 2024 to 2025. In testing for 2026.
12V battery current MACANEV_AUX_BAT_CConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 16 to 47 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -1000000 to 1000000 A
- Unit
- A
0x000002E0 = 736 → = 0.736 A
Confirmed for 2024 to 2025. In testing for 2026.
12V battery sensor temperature MACANEV_AUX_BAT_T_SConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x3E = 62 → = 22 °C
Confirmed for 2024 to 2025. In testing for 2026.
12V battery soc MACANEV_AUX_BAT_SOCConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x64 = 100 → 100 %
Confirmed for 2024 to 2025. In testing for 2026.
12V battery temperature MACANEV_AUX_BAT_TConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x3D = 61 → = 21 °C
Confirmed for 2024 to 2025. In testing for 2026.
12V battery total charge MACANEV_AUX_BAT_CHRG_TOTConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 96 to 127 of the reply, 32 bits.
- Formula
- Range
- 0 to 10000000 Ah
- Unit
- Ah
0x00001124 = 4388 → = 438.8 Ah
Confirmed for 2024 to 2025. In testing for 2026.
12V battery total discharge MACANEV_AUX_BAT_DSCH_TOTConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 128 to 159 of the reply, 32 bits.
- Formula
- Range
- 0 to 10000000 Ah
- Unit
- Ah
0x0000106F = 4207 → = 420.7 Ah
Confirmed for 2024 to 2025. In testing for 2026.
12V battery voltage MACANEV_AUX_BAT_VConfirmed
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 69 V
- Unit
- V
0x264E = 9806 → = 13.806 V
Confirmed for 2024 to 2025. In testing for 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2025. Supported for 2024.
HV battery capacity MACANEV_HVBAT_CAPConfirmed
Total possible energy in the high voltage battery
- Service 22
DID 2AB2 - Module
710 → 77A - Every
86400 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276750 W
- Unit
- W
0x0766 = 1894 → = 94,700 W
Confirmed for 2024 to 2025. In testing for 2026.
HV battery energy MACANEV_HVBAT_KWHConfirmed
Energy stored in the high voltage battery
- Service 22
DID 2AB8 - Module
710 → 77A - Every
1 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000000 W
- Unit
- W
0x02EB = 747 → = 18,675 W
Confirmed for 2024 to 2025. In testing for 2026.
Climate
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025. Supported for 2024.
Control Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. Supported for 2024.
DTCs
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2025. Supported for 2024.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2025. Supported for 2024.
Status
A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Catalyst monitoring CAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
EGR system monitoring EGR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
EGR system monitoring completed EGR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Evaporative system monitoring EVAP_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Heated catalyst monitoring HCAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Misfire monitoring completed MIS_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Oxygen sensor monitoring O2S_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Secondary air system monitoring AIR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2024.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2025. Supported for 2024.
Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2025. Supported for 2024.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Misfire monitoring enabled MIS_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2024.
Engine
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. Supported for 2024.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025. Supported for 2024.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2025. Supported for 2024.
Movement
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2025. Supported for 2024.
Stats
Crashes, driver side MACANEV_CRASH_CNT_DRVRConfirmed
- Service 22
DID 2354 - Module
715 → 77F - Every
3600 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024 to 2025. In testing for 2026.
Crashes, front MACANEV_CRASH_CNT_FRONTConfirmed
- Service 22
DID 2353 - Module
715 → 77F - Every
3600 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024 to 2025. In testing for 2026.
Crashes, passenger side MACANEV_CRASH_CNT_PSNGRConfirmed
- Service 22
DID 2355 - Module
715 → 77F - Every
3600 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024 to 2025. In testing for 2026.
Crashes, rear MACANEV_CRASH_CNT_REARConfirmed
- Service 22
DID 2356 - Module
715 → 77F - Every
3600 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024 to 2025. In testing for 2026.
Crashes, rollover MACANEV_CRASH_CNT_ROLLConfirmed
- Service 22
DID 2357 - Module
715 → 77F - Every
3600 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024 to 2025. In testing for 2026.
Tires
Front left tire pressure MACANEV_TP_FLConfirmed
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 18A1 - Module
70B → 775 - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 bar
- Unit
- bar
0x76 = 118 → = 2.95 bar
Confirmed for 2024 to 2025. In testing for 2026.
Front right tire pressure MACANEV_TP_FRConfirmed
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 18A0 - Module
70B → 775 - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 bar
- Unit
- bar
0x76 = 118 → = 2.95 bar
Confirmed for 2024 to 2025. In testing for 2026.
Rear left tire pressure MACANEV_TP_RLConfirmed
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 18A2 - Module
70B → 775 - Every
5 s - Testing for 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 bar
- Unit
- bar
Confirmed for 2024 to 2025. In testing for 2026.
Rear right tire pressure MACANEV_TP_RRConfirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 18A3 - Module
70B → 775 - Every
5 s - Testing for 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 bar
- Unit
- bar
Confirmed for 2024 to 2025. In testing for 2026.
Trips
Average consumption (category 0) MACANEV_AVG_CSMP_CAT0Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00B0 = 176 → = 17.6 kWh
Confirmed for 2024 to 2025. In testing for 2026.
Average consumption (category 1) MACANEV_AVG_CSMP_CAT1Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00B6 = 182 → = 18.2 kWh
Confirmed for 2024 to 2025. In testing for 2026.
Average consumption (category 2) MACANEV_AVG_CSMP_CAT2Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00BF = 191 → = 19.1 kWh
Confirmed for 2024 to 2025. In testing for 2026.
Average consumption (category 3) MACANEV_AVG_CSMP_CAT3Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00C3 = 195 → = 19.5 kWh
Confirmed for 2024 to 2025. In testing for 2026.
Average consumption (category 4) MACANEV_AVG_CSMP_CAT4Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00DC = 220 → = 22 kWh
Confirmed for 2024 to 2025. In testing for 2026.
Average consumption (category 5) MACANEV_AVG_CSMP_CAT5Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00B2 = 178 → = 17.8 kWh
Confirmed for 2024 to 2025. In testing for 2026.
Average consumption (category 6) MACANEV_AVG_CSMP_CAT6Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x0000 = 0 → = 0 kWh
Confirmed for 2024 to 2025. In testing for 2026.
Range remaining MACANEV_RANGEConfirmed
Pelican can show this parameter as the electric range.
- Service 22
DID 2AB6 - Module
710 → 77A - Every
5 s - Testing for 2026
Example reply from a 2025 Porsche Macan Electric.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mi
- Unit
- mi
0x003A = 58 → 58 mi
Confirmed for 2024 to 2025. In testing for 2026.