Peugeot e-208

Parameters

The Peugeot e-208 has 279 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Average cell voltage value 208_AVG_CELL_V

  • Service 22DID D43D
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Average cell voltage value 208_AVG_CELL_V

  • Service 22DID D43D
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery average temperature 208_BAT_AVG_T

  • Service 22DID D877
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Battery cell 001 health 208_BAT_CELL_001_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 001 voltage 208_BAT_CELL_001_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 002 health 208_BAT_CELL_002_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 002 voltage 208_BAT_CELL_002_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 003 health 208_BAT_CELL_003_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 003 voltage 208_BAT_CELL_003_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 004 health 208_BAT_CELL_004_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 004 voltage 208_BAT_CELL_004_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 005 health 208_BAT_CELL_005_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 005 voltage 208_BAT_CELL_005_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 006 health 208_BAT_CELL_006_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 006 voltage 208_BAT_CELL_006_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 007 health 208_BAT_CELL_007_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 007 voltage 208_BAT_CELL_007_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 008 health 208_BAT_CELL_008_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 008 voltage 208_BAT_CELL_008_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 009 health 208_BAT_CELL_009_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 009 voltage 208_BAT_CELL_009_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 010 health 208_BAT_CELL_010_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 010 voltage 208_BAT_CELL_010_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 011 health 208_BAT_CELL_011_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 011 voltage 208_BAT_CELL_011_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 012 health 208_BAT_CELL_012_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 012 voltage 208_BAT_CELL_012_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 013 health 208_BAT_CELL_013_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 013 voltage 208_BAT_CELL_013_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 014 health 208_BAT_CELL_014_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 014 voltage 208_BAT_CELL_014_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 015 health 208_BAT_CELL_015_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 015 voltage 208_BAT_CELL_015_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 016 health 208_BAT_CELL_016_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 016 voltage 208_BAT_CELL_016_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 017 health 208_BAT_CELL_017_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 017 voltage 208_BAT_CELL_017_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 018 health 208_BAT_CELL_018_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 018 voltage 208_BAT_CELL_018_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 019 health 208_BAT_CELL_019_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 019 voltage 208_BAT_CELL_019_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 020 health 208_BAT_CELL_020_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 020 voltage 208_BAT_CELL_020_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 021 health 208_BAT_CELL_021_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 021 voltage 208_BAT_CELL_021_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 022 health 208_BAT_CELL_022_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 022 voltage 208_BAT_CELL_022_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 023 health 208_BAT_CELL_023_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 023 voltage 208_BAT_CELL_023_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 024 health 208_BAT_CELL_024_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 024 voltage 208_BAT_CELL_024_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 025 health 208_BAT_CELL_025_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 025 voltage 208_BAT_CELL_025_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 026 health 208_BAT_CELL_026_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 026 voltage 208_BAT_CELL_026_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 027 health 208_BAT_CELL_027_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 027 voltage 208_BAT_CELL_027_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 028 health 208_BAT_CELL_028_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 028 voltage 208_BAT_CELL_028_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 029 health 208_BAT_CELL_029_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 029 voltage 208_BAT_CELL_029_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 030 health 208_BAT_CELL_030_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 030 voltage 208_BAT_CELL_030_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 031 health 208_BAT_CELL_031_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 031 voltage 208_BAT_CELL_031_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 032 health 208_BAT_CELL_032_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 032 voltage 208_BAT_CELL_032_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 033 health 208_BAT_CELL_033_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 033 voltage 208_BAT_CELL_033_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 034 health 208_BAT_CELL_034_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 034 voltage 208_BAT_CELL_034_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 035 health 208_BAT_CELL_035_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 035 voltage 208_BAT_CELL_035_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 036 health 208_BAT_CELL_036_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 036 voltage 208_BAT_CELL_036_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 037 health 208_BAT_CELL_037_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 037 voltage 208_BAT_CELL_037_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 038 health 208_BAT_CELL_038_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 038 voltage 208_BAT_CELL_038_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 039 health 208_BAT_CELL_039_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 039 voltage 208_BAT_CELL_039_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 040 health 208_BAT_CELL_040_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 040 voltage 208_BAT_CELL_040_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 041 health 208_BAT_CELL_041_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 041 voltage 208_BAT_CELL_041_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 042 health 208_BAT_CELL_042_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 042 voltage 208_BAT_CELL_042_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 043 health 208_BAT_CELL_043_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 043 voltage 208_BAT_CELL_043_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 044 health 208_BAT_CELL_044_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 044 voltage 208_BAT_CELL_044_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 045 health 208_BAT_CELL_045_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 045 voltage 208_BAT_CELL_045_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 046 health 208_BAT_CELL_046_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 046 voltage 208_BAT_CELL_046_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 047 health 208_BAT_CELL_047_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 047 voltage 208_BAT_CELL_047_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 048 health 208_BAT_CELL_048_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 048 voltage 208_BAT_CELL_048_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 049 health 208_BAT_CELL_049_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 049 voltage 208_BAT_CELL_049_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 050 health 208_BAT_CELL_050_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 050 voltage 208_BAT_CELL_050_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 051 health 208_BAT_CELL_051_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 051 voltage 208_BAT_CELL_051_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 052 health 208_BAT_CELL_052_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 052 voltage 208_BAT_CELL_052_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 053 health 208_BAT_CELL_053_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 053 voltage 208_BAT_CELL_053_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 054 health 208_BAT_CELL_054_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 054 voltage 208_BAT_CELL_054_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 055 health 208_BAT_CELL_055_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 055 voltage 208_BAT_CELL_055_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 056 health 208_BAT_CELL_056_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 056 voltage 208_BAT_CELL_056_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 057 health 208_BAT_CELL_057_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 057 voltage 208_BAT_CELL_057_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 058 health 208_BAT_CELL_058_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 058 voltage 208_BAT_CELL_058_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 059 health 208_BAT_CELL_059_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 059 voltage 208_BAT_CELL_059_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 060 health 208_BAT_CELL_060_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 060 voltage 208_BAT_CELL_060_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 061 health 208_BAT_CELL_061_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 061 voltage 208_BAT_CELL_061_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 062 health 208_BAT_CELL_062_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 062 voltage 208_BAT_CELL_062_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 063 health 208_BAT_CELL_063_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 063 voltage 208_BAT_CELL_063_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 064 health 208_BAT_CELL_064_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 064 voltage 208_BAT_CELL_064_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 065 health 208_BAT_CELL_065_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 065 voltage 208_BAT_CELL_065_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 066 health 208_BAT_CELL_066_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 066 voltage 208_BAT_CELL_066_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 067 health 208_BAT_CELL_067_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 067 voltage 208_BAT_CELL_067_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 068 health 208_BAT_CELL_068_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 068 voltage 208_BAT_CELL_068_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 069 health 208_BAT_CELL_069_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 069 voltage 208_BAT_CELL_069_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 070 health 208_BAT_CELL_070_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 070 voltage 208_BAT_CELL_070_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 071 health 208_BAT_CELL_071_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 071 voltage 208_BAT_CELL_071_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 072 health 208_BAT_CELL_072_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 072 voltage 208_BAT_CELL_072_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 073 health 208_BAT_CELL_073_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 073 voltage 208_BAT_CELL_073_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 074 health 208_BAT_CELL_074_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 074 voltage 208_BAT_CELL_074_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 075 health 208_BAT_CELL_075_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 075 voltage 208_BAT_CELL_075_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 076 health 208_BAT_CELL_076_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 076 voltage 208_BAT_CELL_076_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 077 health 208_BAT_CELL_077_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 077 voltage 208_BAT_CELL_077_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 078 health 208_BAT_CELL_078_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 078 voltage 208_BAT_CELL_078_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 079 health 208_BAT_CELL_079_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 079 voltage 208_BAT_CELL_079_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 080 health 208_BAT_CELL_080_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 080 voltage 208_BAT_CELL_080_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 081 health 208_BAT_CELL_081_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 081 voltage 208_BAT_CELL_081_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 082 health 208_BAT_CELL_082_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 082 voltage 208_BAT_CELL_082_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 083 health 208_BAT_CELL_083_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 083 voltage 208_BAT_CELL_083_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 084 health 208_BAT_CELL_084_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 084 voltage 208_BAT_CELL_084_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 085 health 208_BAT_CELL_085_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 085 voltage 208_BAT_CELL_085_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 086 health 208_BAT_CELL_086_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 086 voltage 208_BAT_CELL_086_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 087 health 208_BAT_CELL_087_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 087 voltage 208_BAT_CELL_087_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 088 health 208_BAT_CELL_088_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 088 voltage 208_BAT_CELL_088_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 089 health 208_BAT_CELL_089_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 089 voltage 208_BAT_CELL_089_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 090 health 208_BAT_CELL_090_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 090 voltage 208_BAT_CELL_090_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 091 health 208_BAT_CELL_091_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 091 voltage 208_BAT_CELL_091_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 092 health 208_BAT_CELL_092_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 092 voltage 208_BAT_CELL_092_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 093 health 208_BAT_CELL_093_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 093 voltage 208_BAT_CELL_093_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 094 health 208_BAT_CELL_094_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,488 to 1,503 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 094 voltage 208_BAT_CELL_094_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,488 to 1,503 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 095 health 208_BAT_CELL_095_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,504 to 1,519 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 095 voltage 208_BAT_CELL_095_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,504 to 1,519 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 096 health 208_BAT_CELL_096_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,520 to 1,535 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 096 voltage 208_BAT_CELL_096_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,520 to 1,535 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 097 health 208_BAT_CELL_097_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,536 to 1,551 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 097 voltage 208_BAT_CELL_097_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,536 to 1,551 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 098 health 208_BAT_CELL_098_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,552 to 1,567 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 098 voltage 208_BAT_CELL_098_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,552 to 1,567 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 099 health 208_BAT_CELL_099_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,568 to 1,583 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 099 voltage 208_BAT_CELL_099_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,568 to 1,583 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 100 health 208_BAT_CELL_100_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,584 to 1,599 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 100 voltage 208_BAT_CELL_100_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,584 to 1,599 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 101 health 208_BAT_CELL_101_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,600 to 1,615 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 101 voltage 208_BAT_CELL_101_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,600 to 1,615 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 102 health 208_BAT_CELL_102_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,616 to 1,631 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 102 voltage 208_BAT_CELL_102_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,616 to 1,631 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 103 health 208_BAT_CELL_103_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,632 to 1,647 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 103 voltage 208_BAT_CELL_103_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,632 to 1,647 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 104 health 208_BAT_CELL_104_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,648 to 1,663 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 104 voltage 208_BAT_CELL_104_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,648 to 1,663 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 105 health 208_BAT_CELL_105_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,664 to 1,679 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 105 voltage 208_BAT_CELL_105_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,664 to 1,679 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 106 health 208_BAT_CELL_106_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,680 to 1,695 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 106 voltage 208_BAT_CELL_106_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,680 to 1,695 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 107 health 208_BAT_CELL_107_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,696 to 1,711 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 107 voltage 208_BAT_CELL_107_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,696 to 1,711 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 108 health 208_BAT_CELL_108_SOH

  • Service 22DID D4B5
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 1,712 to 1,727 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.93 %
Unit
%

In testing for 2019 to 2026.

Battery cell 108 voltage 208_BAT_CELL_108_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,712 to 1,727 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 109 voltage 208_BAT_CELL_109_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,728 to 1,743 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 110 voltage 208_BAT_CELL_110_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,744 to 1,759 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 111 voltage 208_BAT_CELL_111_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,760 to 1,775 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 112 voltage 208_BAT_CELL_112_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,776 to 1,791 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 113 voltage 208_BAT_CELL_113_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,792 to 1,807 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 114 voltage 208_BAT_CELL_114_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,808 to 1,823 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 115 voltage 208_BAT_CELL_115_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,824 to 1,839 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 116 voltage 208_BAT_CELL_116_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,840 to 1,855 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 117 voltage 208_BAT_CELL_117_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,856 to 1,871 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 118 voltage 208_BAT_CELL_118_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,872 to 1,887 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 119 voltage 208_BAT_CELL_119_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,888 to 1,903 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery cell 120 voltage 208_BAT_CELL_120_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,904 to 1,919 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Battery DC current 208_BAT_DC_CURRENT

Pelican can show this parameter as the traction battery current.

  • Service 22DID D816
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val64−1200
Range
-1200 to 67107663 A
Unit
A

In testing for 2019 to 2026.

Battery insulation resistance 208_BAT_INSULATION_RES

  • Service 22DID D47A
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kΩ
Unit
kΩ

In testing for 2019 to 2026.

Battery max unit temperature 208_BAT_MAX_UNIT_T

  • Service 22DID D817
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Battery max unit temperature number 208_BAT_MAX_UNIT_T_NUMBER

  • Service 22DID D445
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2019 to 2026.

Battery min unit temperature 208_BAT_MIN_UNIT_T

  • Service 22DID D87D
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Battery min unit temperature number 208_BAT_MIN_UNIT_T_NUMBER

  • Service 22DID D446
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2019 to 2026.

Battery temperature 208_BAT_T

  • Service 22DID D8EF
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2019 to 2026.

Cell voltage sum 208_CELL_V_SUMM

  • Service 22DID D438
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 V
Unit
V

In testing for 2019 to 2026.

High voltage battery charge 208_HVBAT_SOC_RAW

Pelican can show this parameter as the state of charge.

  • Service 22DID D810
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026.

High voltage battery charge, calibrated 208_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID D410
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026.

High voltage battery health 208_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID D860
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val16
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026.

High voltage battery voltage 208_HVBAT_VOLT

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID D815
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 V
Unit
V

In testing for 2019 to 2026.

High voltage maximum voltage 208_HVBAT_MAX_VOLT

  • Service 22DID D870
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2019 to 2026.

High voltage minimum voltage 208_HVBAT_MIN_VOLT

  • Service 22DID D86F
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2019 to 2026.

Highest voltage cell number 208_HIGHEST_V_CELL

  • Service 22DID D43B
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2019 to 2026.

HV battery energy 208_HVBAT_KWH

Energy stored in the high voltage battery

  • Service 22DID D865
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 kWh
Unit
kWh

In testing for 2019 to 2026.

Lowest voltage cell number 208_LOWEST_V_CELL_NUMBER

  • Service 22DID D43C
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2019 to 2026.

Maximum power the battery can provide for 10 seconds 208_MAX_POWER_BAT_CAN_PROVIDE_10

  • Service 22DID D873
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×1953250000−500
Range
-500 to 33551784 kW
Unit
kW

In testing for 2019 to 2026.

Maximum power the battery can provide for 30 seconds 208_MAX_POWER_BAT_CAN_PROVIDE_30

  • Service 22DID D874
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×1953250000−500
Range
-500 to 33551784 kW
Unit
kW

In testing for 2019 to 2026.

Maximum power the battery can withstand for 10 seconds 208_MAX_POWER_BAT_CAN_10

  • Service 22DID D871
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×1953250000−500
Range
-500 to 33551784 kW
Unit
kW

In testing for 2019 to 2026.

Maximum power the battery can withstand for 30 seconds 208_MAX_POWER_BAT_CAN_30

  • Service 22DID D872
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×1953250000−500
Range
-500 to 33551784 kW
Unit
kW

In testing for 2019 to 2026.

On-board charger temperature 208_ON_BOARD_CHARGER_T

  • Service 22DID D8E1
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2019 to 2026.

Service battery temperature 208_SERVICE_BAT_T

  • Service 22DID D496
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 °C
Unit
°C

In testing for 2019 to 2026.

Service cell voltage value 208_SERVICE_CELL_V

  • Service 22DID D822
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2019 to 2026.

Engine

Air conditioning high side pressure 208_AC_HIGH_SIDE_P

  • Service 22DID D8FF
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 bar
Unit
bar

In testing for 2019 to 2026.

Ambient temperature 208_AAT

  • Service 22DID D434
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2019 to 2026.

Coolant temperature 208_ECT

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID D8FB
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2019 to 2026.

Drive motor coolant inlet temperature 208_DRIVE_MOTOR_CLT_T

  • Service 22DID D8D6
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2019 to 2026.

Drive motor power 208_DRIVE_MOTOR_POWER

  • Service 22DID D8D9
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700 W
Unit
W

In testing for 2019 to 2026.

Drive motor stator temperature 208_DRIVE_MOTOR_STATOR_T

  • Service 22DID D8CD
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2019 to 2026.

Drive motor torque, actual 208_DRIVE_MOTOR_TQ_ACT

  • Service 22DID D8D0
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2019 to 2026.

Drive motor torque, desired 208_DRIVE_MOTOR_TQ_DES

  • Service 22DID D880
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 N·m
Unit
N·m

In testing for 2019 to 2026.

Electric machine torque 208_ELEC_MACHINE_TQ

  • Service 22DID DCB6
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2019 to 2026.

Electric machine torque reduction 208_ELEC_MACHINE_TQ_REDUCTION

  • Service 22DID DC69
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2019 to 2026.

Inverter temperature estimated 208_INVERTER_T_ESTIMATED

  • Service 22DID DC6A
  • Module6A6 → 686
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2019 to 2026.

Inverter temperature, commanded 208_INVERTER_T_CMD

  • Service 22DID DC04
  • Module6A6 → 686
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2019 to 2026.

Minimum cell capacity 208_MIN_CELL_CAP

  • Service 22DID D413
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2019 to 2026.

Temperature difference between the hottest and the coolest cells 208_T_DIFF_HOTEST

  • Service 22DID D878
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2019 to 2026.

Traction circuit coolant temperature 208_TRACTION_CIRCUIT_ECT

  • Service 22DID D8F9
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2019 to 2026.

Movement

Accelerator pedal position 208_ACCEL_PEDAL_POS

  • Service 22DID D407
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2019 to 2026.

Accelerator pedal position 208_ACCEL_PEDAL_POS_6B4

  • Service 22DID D407
  • Module6B4 → 694
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2019 to 2026.

Motor speed 208_MOTOR_SPD

  • Service 22DID DC00
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2019 to 2026.

Vehicle speed 208_VSS

Pelican can show this parameter as the speed.

  • Service 22DID D402
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 km/h
Unit
km/h

In testing for 2019 to 2026.

Vehicle speed 208_VSS_6B4

Pelican can show this parameter as the speed.

  • Service 22DID D802
  • Module6B4 → 694
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×6465535
Range
0 to 4194368 km/h
Unit
km/h

In testing for 2019 to 2026.

Vehicle speed, ESP 208_VSS_ESP

Pelican can show this parameter as the speed.

  • Service 22DID D802
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1953250000
Range
0 to 511 km/h
Unit
km/h

In testing for 2019 to 2026.

Transmission

DC-DC converter temperature 208_DC_DC_CONV_T

  • Service 22DID D8CE
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2019 to 2026.

Trips

Odometer 208_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1024
Range
0 to 4194303 km
Unit
km

In testing for 2019 to 2026.

Odometer 208_ODO_6A2

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6A2 → 682
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2019 to 2026.

Odometer 208_ODO_6A6

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6A6 → 686
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2019 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.