Parameters
The Peugeot 508 has 444 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Accelerator pedal signal 1 voltage 508_ACCEL_PEDAL_SIG_1_V
- Service 22
DID D405 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6.55 to 6.55 V
- Unit
- V
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Accelerator pedal signal 2 voltage 508_ACCEL_PEDAL_SIG_2_V
- Service 22
DID D406 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6.55 to 6.55 V
- Unit
- V
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Approximate position of turbocharger actuator 508_APPROXIMATE_POS
- Service 22
DID D4EC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Battery current 508_BAT_CURRENT
- Service 22
DID D497 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2097152 to 2097151 A
- Unit
- A
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Centralized voltage maintenance device temperature limiter state 508_CENTRALIZED_V_T
- Service 22
DID D759 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Computer power supply voltage 508_COMPUTER_POWER_SUP_V
- Service 22
DID D551 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2014, 2019, 2021. Supported for 2012 to 2013, 2015.
Energy accumulator discharge permission state 508_ENERGY_ACCUMULATOR
- Service 22
DID D74F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Engine control computer supply voltage 508_ENG_CTRL_COMPUTER_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID D422 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 V
- Unit
- V
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Engine oil level sensor voltage 508_ENG_OIL_LEVEL_SENS_V
- Service 22
DID D41E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553 to 6553 mV
- Unit
- mV
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Evaluation of the total resistance of the voltage maintaining device 508_EVALUATION_TOT_RES_V
- Service 22
DID D72D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.511
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Glow plug unit supply voltage 508_PREHEATING_V
- Service 22
DID D50E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 V
- Unit
- V
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Minimum battery voltage at startup 508_MIN_BAT_V_STARTUP
- Service 22
DID D4D4 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 V
- Unit
- V
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Reversible generator voltage 508_REVERSIBLE_GEN_V
- Service 22
DID D713 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 V
- Unit
- V
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Service battery charge state 508_SERVICE_BAT_CHG_ST
- Service 22
DID D742 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Service battery charge status 508_SERVICE_BAT_CHG_STAT
- Service 22
DID D467 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Service battery temperature 508_SERVICE_BAT_T_6A8
- Service 22
DID D496 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Service battery voltage 508_SERVICE_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID D78A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 V
- Unit
- V
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Service battery wear condition 508_SERVICE_BAT_WEAR
- Service 22
DID D741 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Set voltage of energy storage 508_SET_V_ENERGY_STORAGE
- Service 22
DID D734 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96 V
- Unit
- V
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Set voltage of storage battery charging 508_SET_V_STORAGE_BAT
- Service 22
DID D766 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 V
- Unit
- V
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Set voltage of the reversible generator 508_SET_V_REVERSIBLE_GEN
- Service 22
DID D712 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 16.97 V
- Unit
- V
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Stop permitted by voltage maintainer computer 508_STOP_PERMITTED_V
- Service 22
DID D749 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Temperature of the electronic power unit of the voltage maintenance device 508_T_ELECTRONIC_POWER_V
- Service 22
DID D730 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Turbocharger control duty cycle 508_TURBOCHARGER_CTRL
- Service 22
DID D48A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -128 to 127 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Turbocharger first electronic boost 508_TURBOCHARGER_FIRST
- Service 22
DID D48C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Turbocharger position information 508_TURBOCHARGER_POS
- Service 22
DID D4EA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Turbocharger pressure measured 508_TURBOCHARGER_P_MEAS
- Service 22
DID D4D9 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Turbocharger pressure reference 508_TURBOCHARGER_P
- Service 22
DID D556 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Turbocharger, target position 508_TURBOCHARGER_TGT_POS
- Service 22
DID D47B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Voltage at the terminals of the energy accumulator 508_V_TERMINALS_ENERGY
- Service 22
DID D720 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96 V
- Unit
- V
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Voltage maintainer computer request sent 508_V_MAINTAINER_COMPUTER_REQ
- Service 22
DID D748 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Voltage maintainer computer restart permission 508_V_MAINTAINER
- Service 22
DID D747 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Voltage maintainer status 508_V_MAINTAINER_STAT
- Service 22
DID D72C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Climate
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2014 to 2015, 2019. Supported for 2012 to 2013.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2019, 2021.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Anti-lock brake or stability control regulating 508_ABS_EKS_PROCESS_ADJ
- Service 22
DID D474 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Brake circuit pressure 508_BRAKE_CIRCUIT_P
- Service 22
DID D70E - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -55 to 6498 bar
- Unit
- bar
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Brake system backup contactor status 508_BRAKE_SYSTEM_BACKUP
- Service 22
DID D463 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Main brake contactor status 508_MAIN_BRAKE_CONTACTOR
- Service 22
DID D513 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Secondary brake contactor status 508_SECONDARY_BRAKE
- Service 22
DID D514 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Vacuum present in the brake system 508_VACUUM_PRESENT_BRAKE
- Service 22
DID D700 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2019, 2021.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed
Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.
- Service 01
PID 4E - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2019. Supported for 2021.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019. Supported for 2021.
Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 4D - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2019. Supported for 2021.
Status
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Engine
5V power supply state number 1 508_5V_POWER_SUP_ST_1
- Service 22
DID D423 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
5V power supply state number 2 508_5V_POWER_SUP_ST_2
- Service 22
DID D424 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
5V power supply state number 3 508_5V_POWER_SUP_ST_3
- Service 22
DID D425 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
5V power supply state number 4 508_5V_POWER_SUP_ST_4
- Service 22
DID D426 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
12V network allowed stop 508_12V_NETWORK_ALLOWED
- Service 22
DID D74C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Activation count, brake electromagnetic valve B1 508_NUM_ACTIVATIONS_B1
- Service 22
DID D745 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, line pressure control solenoid 508_NUM_LINE_P_CTRL
- Service 22
DID D751 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, the electromagnetic valve of brake B2 508_NUM_ACTIVATIONS_B2
- Service 22
DID D75A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Actual oil pressure 508_ACT_OIL_P
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 12.75 bar
- Unit
- bar
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Additional heater control 1 508_ADDITIONAL_HEATER_1
- Service 22
DID D416 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Air conditioning 508_AC
- Service 22
DID D4AF - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Air conditioning compressor current 508_AC_COMP_CURRENT
- Service 22
DID D41C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Air conditioning pressure 508_AC_P
- Service 22
DID D421 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Air doser first electronic loading 508_AIR_DOSER_FIRST
- Service 22
DID D53B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Air flow 508_AIR_FLOW
- Service 22
DID D489 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2014, 2019, 2021. Supported for 2012 to 2013, 2015.
Air flow target 508_AIR_FLOW_TGT
- Service 22
DID D48E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Air metering valve duty cycle 508_AIR_METERING_VLV
- Service 22
DID D461 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Air metering valve position 508_AIR_METERING_VLV_POS
- Service 22
DID D54F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Air metering valve, target position 508_AIR_METERING_VLV_TGT
- Service 22
DID D460 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Air temperature by air flow meter 508_AIR_T_AIR_FLOW_METER
- Service 22
DID D54E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Alternator load value 508_ALTERNATOR_LOAD
- Service 22
DID D4A5 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Ambient air temperature 508_AAT_6A9
- Service 22
DID D552 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
ANTI START PROGRAMMING STATUS 508_ANTI_START
- Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Assessment of thermal aging of the particulate filter 508_ASSESSMENT_THERMAL
- Service 22
DID D532 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 12799 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Atmospheric pressure 508_ATMOSPHERIC_P
- Service 22
DID D465 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Automatic restart request from body control module 508_AUTOMATIC_RESTART_REQ_BSI
- Service 22
DID D70A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Automatic restart request from engine management computer 508_AUTOMATIC_RESTART
- Service 22
DID D709 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Automatic stop allowed by body control module 508_AUTOMATIC_STOP
- Service 22
DID D703 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Automatic stop allowed by power steering computer 508_AUTOMATIC_STOP_ALLOWED_POWER_STEER
- Service 22
DID D705 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Auxiliary heater 2 control 508_AUXILIARY_HEATER_2
- Service 22
DID D417 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Average mileage for the last 10 regenerations 508_AVG_MILEAGE_LAST_10
- Service 22
DID D525 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4095 km
- Unit
- km
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Boost air temperature 508_BOOST_AIR_T
- Service 22
DID D411 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Button state 508_BUTTON_ST
- Service 22
DID D517 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2014, 2019, 2021. Supported for 2012 to 2013, 2015.
Camshaft/crankshaft position synchronization 508_CAM_CRANK_POS
- Service 22
DID D418 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2019. Supported for 2021.
CHANGE REPORT IN PROGRESS 508_CHANGE_REPORT
- Service 22
DID D516 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Closed loop soot load assessment of the diesel particulate filter 508_CLOSED_LOOP_SOOT
- Service 22
DID D54B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.99 g/L
- Unit
- g/L
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Combustion engine state 508_ICE_ST
- Service 22
DID D709 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2021.
Commanded oil pressure 508_CMD_OIL_P
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 bar
- Unit
- bar
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019. Supported for 2021.
Commanded wastegate A position WG_A_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Commanded wastegate B position WG_B_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Computer lock 508_COMPUTER_LOCK
- Service 22
DID DADD - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Computer remote wake-up state 508_COMPUTER_WAKE_UP_ST
- Service 22
DID D515 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Computer restarts since memory erase 508_CNT_NUM_RE
- Service 22
DID D4D8 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Computer temperature 508_COMPUTER_T
- Service 22
DID D435 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Control current of electromagnetic valve for changing the pressure in the brake system B2 508_CTRL_CURRENT_P_B2
- Service 22
DID D622 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Control current of the electromagnetic valve for changing the pressure in the brake system B1 508_CTRL_CURRENT_P_B1
- Service 22
DID D608 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Controlled air supply module 508_CONTROLLED_AIR_SUP
- Service 22
DID D4A0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Coolant temperature 508_ECT_6A8
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID D415 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Coolant temperature target 508_ECT_TGT
- Service 22
DID D40D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Coolant temperature, corrected 508_ECT_CORRECTED
- Service 22
DID D40A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Cruise control, RW status 508_CRUISE_CTRL_RW_STAT
- Service 22
DID D4B0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Cylinder 1 injector flow correction 508_CYL_1_INJ_FLOW_CORR
- Service 22
DID D546 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Cylinder 2 injector flow correction 508_CYL_2_INJ_FLOW_CORR
- Service 22
DID D547 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Cylinder 3 injector flow correction 508_CYL_3_INJ_FLOW_CORR
- Service 22
DID D548 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Cylinder 4 injector flow correction 508_CYL_4_INJ_FLOW_CORR
- Service 22
DID D549 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Date 508_DATE
- Service 22
DID D4CA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 s
- Unit
- s
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Diesel particulate filter differential pressure sensor signal deviation from reference value 508_DPF_DIFF_P_SENS_SIG
- Service 22
DID D518 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Diesel particulate filter regeneration status 508_DPF_REGEN_STAT
- Service 22
DID D521 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Driver presence 508_DRIVER_PRESENCE
- Service 22
DID D723 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Driver, requested torque value 508_DRIVER_REQ_TQ
- Service 22
DID D507 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Economy mode off state 508_ECO_MODE_OFF_ST
- Service 22
DID D724 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
EGR error EGR_ERRSAE J1979Confirmed
- Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2019.
Electric cooling fan control 508_GMV_ELEC_COOLING_FAN
- Service 22
DID D42F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Energy accumulator state transfer 508_ENERGY_ACCUMULATOR_ST
- Service 22
DID D755 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Energy accumulator temperature limiter state 508_ENERGY_ACCUMULATOR_T
- Service 22
DID D758 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Engine control module status 508_ENG_CTRL_MODULE_STAT
- Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Engine coolant temperature 508_ECT_6A9
- Service 22
DID D555 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2014, 2019, 2021. Supported for 2012 to 2013, 2015.
Engine oil dilution protection status 508_ENG_OIL_DILUTION
- Service 22
DID D524 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Engine operating mode 508_ENG_OP_MODE
- Service 22
DID D553 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 8191 rpm
- Unit
- rpm
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine restart counter 508_ENG_RESTART_CNT
- Service 22
DID D406 - Module
6A9 → 689 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine restart counter by stop and start function 508_ENG_RESTART_CNT_STOP
- Service 22
DID D71B - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Engine restart request sent by ESP computer 508_ENG_RESTART_REQ_SENT
- Service 22
DID D70D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2014, 2019, 2021. Supported for 2012 to 2013, 2015.
Engine stalls 508_ENG_STALLS
- Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine start prohibition control, start lock 508_ENG_START
- Service 22
DID D703 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine stop time 508_ENG_STOP_TIME
- Service 22
DID D477 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 s
- Unit
- s
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Engine torque 508_ENG_TQ
- Service 21
PID C3 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Estimated torque of internal friction of the engine 508_ESTIMATED_TQ
- Service 22
DID D4E2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Evaluation of carbon content in engine oil 508_EVALUATION_CARBON
- Service 22
DID D523 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Evaluation of the degree of dilution of motor oil 508_EVALUATION_DEGREE
- Service 22
DID D51F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Evaluation of the exhaust gas flow using the nox sensor 508_EVALUATION_EXH_GAS
- Service 22
DID D542 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364800 to 214748364700 L
- Unit
- L
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Exhaust gas flow through the particulate filter 508_EXH_GAS_FLOW_THROUGH
- Service 22
DID D533 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 14399782 L
- Unit
- L
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Exhaust gas pressure at the outlet of the particulate filter 508_EXH_GAS_P_OUTLET_PF
- Service 22
DID D544 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Exhaust gas recirculation high limit electronic loading 508_EGR_HIGH_LIM
- Service 22
DID D553 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Exhaust gas recirculation low limit electronic loading 508_EGR_LOW_LIM
- Service 22
DID D552 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Exhaust gas recirculation valve duty cycle 508_EGR_VLV_CTRL_SIG_RCO
- Service 22
DID D511 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Exhaust gas recirculation valve first electronic loading 508_EGR_VLV_FIRST
- Service 22
DID D53A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Exhaust gas recirculation valve position 508_EGR_VLV_POS
- Service 22
DID D509 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Exhaust gas recirculation valve set position 508_EGR_VLV_SET_POS
- Service 22
DID D510 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Expected generator supplier identifier of the reversible generator 508_EXPECTED_GEN
- Service 22
DID D789 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Expected identifier of electronic power circuit of reversible generator generator 508_EXPECTED_IDENTIFIER_ELECTRONIC
- Service 22
DID D788 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Expected identifier of reversible generator 508_EXPECTED_IDENTIFIER
- Service 22
DID D787 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
FUGITIVE TRIP IN EMERGENCY MODE 508_FUGITIVE_TRIP
- Service 22
DID D671 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Generator mode 508_GEN_MODE
- Service 22
DID D714 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 19125 rpm
- Unit
- rpm
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Generator shutdown 508_GEN_SHUTDOWN
- Service 22
DID D75B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Glow plug plug set temperature 508_PREHEATING_T
- Service 22
DID D50F - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Glow plug relay status 508_STAT_PRE_POST
- Service 22
DID D50D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Identifier of the electronic power circuit of the reversible generator 508_IDENTIFIER
- Service 22
DID D732 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Identifier of the supplier of the reversible generator 508_IDENTIFIER_SUPPLIER
- Service 22
DID D733 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Immobilizer code programming status 508_IMMOBILIZER_CODE
- Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Indicated engine torque 508_INDICATED_ENG_TQ
- Service 22
DID D4D2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Injector code 1 508_INJ_CODE_1
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 47 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Injector code 2 508_INJ_CODE_2
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 72 to 111 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Injector code 3 508_INJ_CODE_3
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 136 to 175 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Injector code 4 508_INJ_CODE_4
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 200 to 239 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Intake air temperature IATSAE J1979Confirmed
- Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2014, 2019, 2021. Supported for 2012 to 2013, 2015.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Line pressure solenoid valve control current 508_SLT_LINE_P_VARIATION
- Service 22
DID D606 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Lock status 508_LOCK_STAT
- Service 22
DID DADD - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Long-term regeneration capability 508_LONG_TERM_REGEN
- Service 22
DID D54D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Mass of urea injected for thermal protection of urea injector 508_MASS_UREA_INJECTED
- Service 22
DID D56B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310 g
- Unit
- g
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Maximum allowable torque 508_MAX_ALLOWABLE_TQ
- Service 22
DID D506 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured current of electromagnetic valve for changing the pressure in the brake system B2 508_MEAS_CURRENT_P_B2
- Service 22
DID D623 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured current of the electromagnetic valve for changing the pressure in the brake system B1 508_MEAS_CURRENT_P_B1
- Service 22
DID D609 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured line pressure variation solenoid valve current 508_MEAS_LINE_P
- Service 22
DID D607 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Mileage remaining before diesel particulate filter replacement 508_MILEAGE_REMAINING
- Service 22
DID D530 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -524288 to 524272 km
- Unit
- km
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Mileage since last diesel particulate filter replacement 508_MILEAGE_SINCE_DPF
- Service 22
DID D531 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 524280 km
- Unit
- km
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Mileage since last oil change 508_MILEAGE_SINCE_OIL
- Service 22
DID D43F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Mixture enrichment measured by nox sensor at inlet 508_MIXTURE_ENRICHMENT
- Service 22
DID D571 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Mixture enrichment measured by nox sensor at outlet 508_MIXTURE_ENRICHMENT_MEAS
- Service 22
DID D55B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Movement of controlled air supply module 508_MOVEMENT_CONTROLLED
- Service 22
DID D4EB - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Neutral position sensor status 508_NEUTRAL_POS_SENS
- Service 22
DID D438 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Nox sensor heating control 508_NOX_SENS_HEATING
- Service 22
DID D554 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Nox sensor signal status at the inlet 508_NOX_SENS_SIG_STAT_INLET
- Service 22
DID D572 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Nox sensor signal status at the outlet 508_NOX_SENS_SIG_STAT
- Service 22
DID D573 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Nox system operating status 508_NOX_SYSTEM_OP_STAT
- Service 22
DID D540 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Number of engine stop information deletion cycles 508_NUM_ENG_STOP
- Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Oil pressure 508_OIL_P
- Service 22
DID D429 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Oil pressure reference value 508_OIL_P_REFERENCE
- Service 22
DID D464 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Oil pressure regulation control 508_OIL_P_REGULATION
- Service 22
DID D43B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Oil temperature 508_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID D47D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Open loop soot load assessment of the diesel particulate filter 508_OPEN_LOOP_SOOT_LOAD
- Service 22
DID D54A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 63.99 g/L
- Unit
- g/L
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Outside air temperature 508_AAT_6A8
- Service 22
DID D414 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Particulate filter differential pressure 508_PF_DIFF_P
- Service 22
DID D520 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Power consumed for heating the pipelines of the urea injection system 508_POWER_CONSUMED
- Service 22
DID D580 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Power spent on heating the urea injection system pipes, percentage ratio 508_POWER_SPENT_ON
- Service 22
DID D53C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Powertrain condition 508_POWERTRAIN_COND
- Service 22
DID D4BA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Preheating relay control 508_PREHEATING_RELAY
- Service 22
DID D50C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Presence of the identifier of the reversible generator 508_PRESENCE_IDENTIFIER
- Service 22
DID D731 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Pressure-based injection permission for urea solution 508_P_BASED_INJ
- Service 22
DID D514 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Problems detected while transmitting unlock code 508_PROBLEMS_DETECTED
- Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Problems detected while transmitting unlock code 508_PROBLEMS_DETECTED_WHILE
- Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Real engine torque 508_REAL_ENG_TQ
- Service 22
DID D554 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Regeneration enable 508_REGEN_ENABLE
- Service 22
DID D528 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Remaining urea solution in the urea tank 508_REMAINING_UREA
- Service 22
DID D517 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63999
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Remote wake-up circuit status 508_REMOTE_WAKE_UP
- Service 22
DID D705 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Remote wake-up state 508_REMOTE_WAKE_UP_ST
- Service 22
DID D708 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Request to turn on the engine diagnostic indicator 508_REQ_TURN_ON_ENG
- Service 22
DID D511 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Requested value controlled thermostat 508_REQ_CONTROLLED
- Service 22
DID D586 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 399 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Restart request sent by power steering computer 508_RESTART_REQ_SENT
- Service 22
DID D70C - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Restart request sent by suspension computer 508_RESTART_REQ_SENT_SUSPENSION
- Service 22
DID D70E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Return to engine start and restart control by starter 508_RETURN_ENG_START
- Service 22
DID D764 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Return to starter engine restart control 508_RETURN_STARTER_ENG
- Service 22
DID D761 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Reverse generator status 508_REVERSE_GEN_STAT
- Service 22
DID D716 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Reversible generator torque 508_REVERSIBLE_GEN_TQ
- Service 22
DID D715 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Service network related engine restart request 508_SERVICE_NETWORK
- Service 22
DID D74B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2021.
Short-term regeneration capability 508_SHORT_TERM_REGEN
- Service 22
DID D54C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Soot clogging level of diesel particulate filter 508_SOOT_CLOGGING_LEVEL
- Service 22
DID D52F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6399 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Specified volume of injected urea solution 508_SPEC_VOLUME_INJECTED
- Service 22
DID D550 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Sport mode contactor state 508_SPORT_MODE_CONTACTOR
- Service 22
DID D503 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Start inhibit control, wired 508_START_INHIBIT_CTRL
- Service 22
DID D767 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Start or restart inhibition transmitted by engine management computer 508_START_OR_RESTART
- Service 22
DID D71E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Start prohibition 508_START_PROHIBITION
- Service 22
DID D51B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Starter activation counter 508_STARTER_ACTIVATION
- Service 22
DID D71F - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Starter control interface unit operating status 508_STARTER_CTRL
- Service 22
DID D72A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Starter duty cycle 508_STARTER_DUTY
- Service 22
DID D478 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 s
- Unit
- s
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Starter engagement status 508_STARTER_ENGAGEMENT
- Service 22
DID D4C3 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
State lock/unlock control unit 508_ST_LOCK_UNLOCK_CTRL
- Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Status of internal ignition motor 508_STAT_INTERNAL_IGN
- Service 22
DID D412 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Status of the energy accumulator 508_STAT_ENERGY
- Service 22
DID D722 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Stop allowed by ESP computer 508_STOP_ALLOWED_ESP
- Service 22
DID D706 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Stop and start function state 508_STOP_START_FUNCTION
- Service 22
DID D725 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Stop and start switch 508_STOP_START_SWITCH
- Service 22
DID D726 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Stop permitted by suspension computer 508_STOP_PERMITTED
- Service 22
DID D707 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Temperature of the energy accumulator 508_T_ENERGY_ACCUMULATOR
- Service 22
DID D721 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Temperature of the urea solution in the urea tank 508_T_UREA_SOLUTION_UREA
- Service 22
DID D56D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
The composition of the mixture is calculated by the oxygen sensor 508_COMPOSITION_MIXTURE
- Service 22
DID D570 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2021.
Torque corresponding to driver requirement 508_TQ_CORRESPONDING
- Service 22
DID D4E3 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Torque supplied or taken by generator 508_TQ_SUPPLIED_OR_TAKEN
- Service 22
DID D728 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Total mass of additive accumulated in the diesel particulate filter 508_TOT_MASS_ADDITIVE
- Service 22
DID D526 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 511 g
- Unit
- g
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Total mass of additive accumulated in the diesel particulate filter 508_TOT_MASS_ADDITIVE_ACCUMULATED_DPF
- Service 22
DID D527 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047 g
- Unit
- g
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Total mileage 508_ODO_6A8
Pelican can show this parameter as the odometer.
- Service 22
DID D49C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Towing device configured 508_CAN_VEH_BE_EQUIPPED
- Service 22
DID D557 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Traction or stability control regulating 508_ASR_OR_ESP_SYSTEM
- Service 22
DID D512 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Transmission fluid temperature 508_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2019.
Urea mass fraction 508_UREA_MASS_FRACTION
- Service 22
DID D58C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Urea solution injected amount 508_UREA_SOLUTION
- Service 22
DID D568 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Urea solution injection permission based on temperature value 508_UREA_SOLUTION_INJ_ON_T
- Service 22
DID D515 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Urea solution pressure 508_UREA_SOLUTION_P
- Service 22
DID D53E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 bar
- Unit
- bar
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Urea solution type in urea tank 508_UREA_SOLUTION_TYPE
- Service 22
DID D58D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Urea tank heating current 508_UREA_TANK_HEATING
- Service 22
DID D581 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Urea tank heating current, percentage 508_UREA_TANK_HEATING_CURRENT
- Service 22
DID D51E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Vacuum circuit vacuum 508_VACUUM_CIRCUIT
- Service 22
DID D73B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Value during generator load smooth increase 508_DURING_GEN_LOAD
- Service 22
DID D753 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Vehicle hour meter 508_VEH_HOUR_METER
- Service 22
DID D801 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 s
- Unit
- s
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Vehicle mileage remaining before filling the tank with urea solution 508_VEH_MILEAGE
- Service 22
DID D513 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 km
- Unit
- km
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Vehicle mileage since the last oil change under severe vehicle operating conditions 508_VEH_MILEAGE_SINCE
- Service 22
DID D534 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km
- Unit
- km
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Volume of urea solution measured in urea tank 508_VOLUME_UREA_SOLUTION
- Service 22
DID D558 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 L
- Unit
- L
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Wastegate A position WG_A_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Wastegate B position WG_B_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Water in diesel 508_WATER_DIESEL
- Service 22
DID D52C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Winter mode switch state 508_WINTER_MODE_SWITCH
- Service 22
DID D502 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Internal
Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.
Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 kPa
- Unit
- kPa
Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.
Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.
Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.
Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012 to 2013, 2015, 2019, 2021.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2014, 2021. Supported for 2012 to 2013, 2015, 2019.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2014. Supported for 2012 to 2013, 2015.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2014, 2021. Supported for 2012 to 2013, 2015, 2019.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2014. Supported for 2012 to 2013, 2015.
Fuel
Amount of fuel additive remaining in the additive tank 508_AMOUNT_FUEL_ADDITIVE
- Service 22
DID D56C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Calculated fuel injection amount 508_CALC_FUEL_INJ_AMOUNT
- Service 22
DID D563 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Desired high pressure common rail fuel pressure 508_DES_HIGH_P_COMMON_P
- Service 22
DID D445 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 bar
- Unit
- bar
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L/h
- Unit
- L/h
Confirmed for 2021.
First fuel additive injection state 508_FIRST_FUEL_ADDITIVE
- Service 22
DID D56F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Fuel pressure 508_FUEL_P
- Service 22
DID D41F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Fuel temperature 508_FUEL_T
- Service 22
DID D42A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
High fuel pressure measured 508_HIGH_FUEL_P_MEAS
- Service 22
DID D446 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 bar
- Unit
- bar
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Injection angle of the high-pressure fuel pump 508_INJ_ANG_HIGH_P_FUEL
- Service 22
DID D588 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Low pressure fuel pump actuator duty cycle 508_LOW_P_FUEL_PMP
- Service 22
DID D472 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Low pressure fuel pump status 508_LOW_P_FUEL_PMP_STAT
- Service 22
DID D4ED - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Minimum fuel level 508_MIN_FLI
- Service 22
DID D56A - Module
6A8 → 688 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Movement
Accelerator pedal position 508_ACCEL_PEDAL_POS
- Service 21
PID C3 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.45 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Accelerator pedal position 508_ACCEL_PEDAL_POS_6A9
- Service 22
DID D505 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Accelerator pedal position, recalculated 508_ACCEL_PEDAL_POS_RECALCULATED
- Service 22
DID D407 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Accelerator pedal position, track 1 508_ACCEL_PEDAL_POS_1
- Service 22
DID D491 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 399 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Accelerator pedal position, track 2 508_ACCEL_PEDAL_POS_2
- Service 22
DID D492 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 399 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Clutch release state at stop, creep speed reduction 508_CLU_RELEASE_ST_STOP
- Service 22
DID D672 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Crankshaft speed 508_CRANK_SPD
- Service 22
DID D462 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 rpm
- Unit
- rpm
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Crankshaft speed determined by camshaft sensor 508_CRANK_SPD_DETERMINED
- Service 22
DID D499 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 rpm
- Unit
- rpm
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Cruise control set speed 508_CRUISE_CTRL_SET_SPD
- Service 22
DID D475 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Engine RPM 508_RPM
Pelican can show this parameter as the engine speed.
- Service 22
DID D400 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Engine RPM 508_RPM_6A9
Pelican can show this parameter as the engine speed.
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Input shaft speed 508_INPUT_SHFT_SPD
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Set speed of electric cooling fan 508_SET_SPD_ELEC_COOLING
- Service 22
DID D4AA - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
STATUS COMMANDS REGULATION OR LIMITATION SPEED 508_STAT_COMMANDS
- Service 22
DID D704 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Torque converter slip speed, measured 508_TQ_CONV_SLIP_SPD
- Service 22
DID D654 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -8128 to 8192 rpm
- Unit
- rpm
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Vehicle speed 508_VSS
Pelican can show this parameter as the speed.
- Service 21
PID C8 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Vehicle speed 508_VSS_6A8
Pelican can show this parameter as the speed.
- Service 22
DID D402 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 km/h
- Unit
- km/h
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Vehicle speed 508_VSS_6A9
Pelican can show this parameter as the speed.
- Service 22
DID D711 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2014 to 2015, 2019, 2021. Supported for 2012 to 2013.
Vehicle speed limiter set speed 508_VSS_LIMITER_SET_SPD
- Service 22
DID D476 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Vehicle speed limiter status, LW 508_VSS_LIMITER_STAT_LW
- Service 22
DID D4C0 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2014, 2019. Supported for 2012 to 2013, 2015, 2021.
Tires
Average front wheel speed 508_AVG_FRONT_WHL_SPD
- Service 22
DID D530 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2621 rpm
- Unit
- rpm
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Average speed front wheels 508_AVG_SPD_FRONT_WHEELS
- Service 22
DID D533 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Counter of occurrence of enhanced resonance of the twin flywheel of the engine 508_CNT_OCCURRENCE
- Service 22
DID D4E4 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Counter of occurrence of resonance of the twin flywheel of the engine 508_CNT_OCCURRENCE_RESONANCE
- Service 22
DID D4E5 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Rear left wheel speed 508_RL_WHL_SPD
- Service 22
DID D531 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Rear right wheel speed 508_RR_WHL_SPD
- Service 22
DID D532 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Transmission
Activation count, additional oil pump, ATN8 gearbox 508_NUM_ADDITIONAL_OIL
- Service 22
DID D750 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, clutch electromagnetic valve C2 508_NUM_ACTIVATIONS_CLU_ELECTROMAGNETIC_VLV_C2
- Service 22
DID D743 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, clutch electromagnetic valve C3 508_NUM_ACTIVATIONS_CLU_C3
- Service 22
DID D744 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, clutch protection C1 508_NUM_ACTIVATIONS_CLU_C1
- Service 22
DID D731 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, clutch protection C2 508_NUM_ACTIVATIONS_CLU_C2
- Service 22
DID D731 - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, gear 7 508_NUM_ACTIVATIONS_GEAR_7
- Service 22
DID D75B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, shift solenoid SC2 508_NUM_SHIFT_SOLENOID
- Service 22
DID D752 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, shift solenoid SC3 508_NUM_SHIFT_SOLENOID_ACTIVATIONS_SC3
- Service 22
DID D753 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, the electromagnetic valve for controlling the automatic transmission locking finger in position p 508_NUM_ACTIVATIONS_P
- Service 22
DID D758 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, the electromagnetic valve of clutch C4 508_NUM_ACTIVATIONS_C4
- Service 22
DID D759 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, the electromagnetic valve of the clutch C1 508_NUM_ACTIVATIONS_C1
- Service 22
DID D742 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, torque converter lockup electromagnetic valve 508_NUM_ACTIVATIONS_TQ
- Service 22
DID D746 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation of additional oil pump, ATN8 gearbox 508_ACTIVATION
- Service 22
DID D616 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Additional oil pump control status, atn8 transmission 508_ADDITIONAL_OIL_PMP
- Service 22
DID D617 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic restart request from transmission computer 508_AUTOMATIC_RESTART_REQ
- Service 22
DID D70B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Automatic stop allowed by gearbox computer 508_AUTOMATIC_STOP_ALLOWED
- Service 22
DID D704 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Automatic transmission fluid temperature 508_AUTOMATIC_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID D550 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic transmission in emergency mode 508_AUTOMATIC_TRANS_EMERGENCY
- Service 22
DID D670 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic transmission in park position 508_AUTOMATIC_TRANS_PARK
- Service 22
DID D70B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic transmission input shaft mode, calculated 508_AUTOMATIC_TRANS_INPUT_SHFT_MODE
- Service 22
DID D651 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070 rpm
- Unit
- rpm
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic transmission input shaft mode, measured 508_AUTOMATIC_TRANS_INPUT_SHFT
- Service 22
DID D650 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070 rpm
- Unit
- rpm
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic transmission lubrication solenoid control current 508_AUTOMATIC_TRANS_LUBRICATION
- Service 22
DID D61A - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic transmission oil aging sensor 508_AUTOMATIC_TRANS_OIL
- Service 22
DID D405 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic transmission oil drain 508_DRAIN_TRANS
- Service 22
DID D509 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic transmission output shaft mode, calculated 508_AUTOMATIC_TRANS_OUTPUT_SHFT_MODE
- Service 22
DID D653 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -8128 to 4186112 rpm
- Unit
- rpm
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic transmission output shaft mode, measured 508_AUTOMATIC_TRANS_OUTPUT
- Service 22
DID D652 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic transmission overheat indicator request 508_AUTOMATIC_TRANS
- Service 22
DID D510 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic transmission torque request 508_AUTOMATIC_TRANS_TQ
- Service 22
DID D508 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Calculated gear in gearbox 508_CALC_GEAR_GEARBOX
- Service 22
DID D409 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Calculated nox content at the inlet of the nox catalytic converter 508_CALC_NOX_CONTENT
- Service 22
DID D53F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4194303
- Unit
- Raw value
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Clutch pedal 508_CLU_PEDAL
- Service 22
DID D404 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Clutch pedal position value 508_CLU_PEDAL_POS
- Service 22
DID D469 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Control current of electromagnetic valve for regulating the pressure in the control system of the oil pressure accumulator, AMN8 gearbox 508_CTRL_CURRENT_P_P
- Service 22
DID D625 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Control current of electromagnetic valve of actuator of automatic transmission lock-up in position p 508_CTRL_CURRENT_ELECTROMAGNETIC_VLV_P
- Service 22
DID D61E - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Control current of electromagnetic valve of change of pressure of torque converter lock-up 508_CTRL_CURRENT_P
- Service 22
DID D61C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Control current of the electromagnetic valve for changing the gear shift SC2 508_CTRL_CURRENT
- Service 22
DID D60A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Control current of the electromagnetic valve of change of pressure of clutch C3 508_CTRL_CURRENT_P_C3
- Service 22
DID D614 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Control current of the electromagnetic valve of change of pressure of clutch C4 508_CTRL_CURRENT_P_C4
- Service 22
DID D620 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Control current of the solenoid valve for changing the pressure of the clutch C1 508_CTRL_CURRENT_P_C1
- Service 22
DID D610 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Control current of the solenoid valve for changing the pressure of the clutch C2 508_CTRL_CURRENT_P_C2
- Service 22
DID D612 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engaged gear 508_ENGAGED_GEAR
- Service 22
DID D43D - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Engaged gear 508_ENGAGED_GEAR_6A9
- Service 22
DID D501 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Evaluation of the thermal aging of the NOx catalytic converter 508_EVALUATION_THERMAL
- Service 22
DID D541 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 99.99 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Exhaust gas temperature after upstream catalytic converter 508_EXH_GAS_T_AFTER_PRE
- Service 22
DID D555 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Exhaust gas temperature before upstream catalytic converter 508_EXH_GAS_T_BEFORE_PRE
- Service 22
DID D52E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Gear in the process of engaging 508_GEAR_PROCESS
- Service 22
DID D43E - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Gear shift knob under steering wheel 508_GEAR_SHIFT_KNOB
- Service 22
DID D520 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Gear shift lever position displayed on instrument panel 508_GEAR_SHIFT_LEVER_POS_ON
- Service 22
DID D500 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Maximum clutch travel during gear shift 508_MAX_CLU_TRAVEL
- Service 22
DID D498 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Measured current of control of electromagnetic valve of automatic transmission lubrication 508_MEAS_CURRENT_CTRL
- Service 22
DID D61B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured current of control of electromagnetic valve of change of pressure of torque converter lock-up 508_MEAS_CURRENT_CTRL_P
- Service 22
DID D61D - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured current of the electromagnetic valve for changing the gear shift SC2 508_MEAS_CURRENT
- Service 22
DID D60B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured current of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 508_MEAS_CURRENT_P_P
- Service 22
DID D626 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured current of the electromagnetic valve of change of pressure of clutch C3 508_MEAS_CURRENT_P_C3
- Service 22
DID D615 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured current of the electromagnetic valve of change of pressure of clutch C4 508_MEAS_CURRENT_P_C4
- Service 22
DID D621 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured current of the solenoid valve for changing the pressure of the clutch C1 508_MEAS_CURRENT_P_C1
- Service 22
DID D611 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured current of the solenoid valve for changing the pressure of the clutch C2 508_MEAS_CURRENT_P_C2
- Service 22
DID D613 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured current of the solenoid valve for controlling the locking finger of the automatic transmission in position p 508_MEAS_CURRENT_P
- Service 22
DID D61F - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Nitrogen oxide content after catalytic converter, ppm 508_NOX_CONTENT_AFTER
- Service 22
DID D53D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 508_NOX_CONTENT_MEAS
- Service 22
DID D545 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 508_NOX_CONTENT_MEAS_INLET_NOX
- Service 22
DID D576 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Nox catalytic converter urea content 508_NOX_CATALYTIC_CONV
- Service 22
DID D55D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 g
- Unit
- g
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Number of engagements of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 508_NUM_ENGAGEMENTS_P_P
- Service 22
DID D75D - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of gear engagements 1 508_NUM_GEAR_ENGAGEMENTS_1
- Service 22
DID D747 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of gear engagements 2 508_NUM_GEAR_ENGAGEMENTS_2
- Service 22
DID D748 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of gear engagements 3 508_NUM_GEAR_ENGAGEMENTS_3
- Service 22
DID D749 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of gear engagements 4 508_NUM_GEAR_ENGAGEMENTS_4
- Service 22
DID D74A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of gear engagements 5 508_NUM_GEAR_ENGAGEMENTS_5
- Service 22
DID D74B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of gear engagements 6 508_NUM_GEAR_ENGAGEMENTS_6
- Service 22
DID D74C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of gear engagements 8 508_NUM_GEAR_ENGAGEMENTS_8
- Service 22
DID D75C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of gear engagements n 508_NUM_GEAR_ENGAGEMENTS_N
- Service 22
DID D74E - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of gear engagements right 508_NUM_GEAR_ENGAGEMENTS
- Service 22
DID D74D - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of shift solenoid operated automatic transmission lubrication control valve 508_NUM_SHIFT_SOLENOID_OPERATED
- Service 22
DID D756 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of shift solenoid operated SC4 508_NUM_SHIFT_SOLENOID_OPERATED_SC4
- Service 22
DID D754 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of shift solenoid operated SC5 508_NUM_SHIFT_SOLENOID_OPERATED_SC5
- Service 22
DID D755 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of shift solenoid operated torque converter lock-up pressure regulating valve 508_NUM_SHIFT_SOLENOID_P
- Service 22
DID D757 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Operating mode used by the automatic transmission 508_OP_MODE_USED
- Service 22
DID D673 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Position of the gearshift lever 508_POS_GEARSHIFT_LEVER
- Service 22
DID D700 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Proportional clutch pedal sensor 508_PROPORTIONAL_CLU
- Service 22
DID D56E - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Reverse gear contactor status 508_REVERSE_GEAR
- Service 22
DID D43C - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
SC5 shift solenoid control current 508_SC5_SHIFT_SOLENOID
- Service 22
DID D618 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
SC5 shift solenoid measured current 508_SC5_SHIFT_SOLENOID_MEAS
- Service 22
DID D619 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Shift solenoid control current SC3 508_SHIFT_SOLENOID_CTRL
- Service 22
DID D60C - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Shift solenoid control current SC4 508_SHIFT_SOLENOID_CTRL_CURRENT_SC4
- Service 22
DID D60E - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Shift solenoid measured current SC3 508_SHIFT_SOLENOID_MEAS
- Service 22
DID D60D - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Shift solenoid measured current SC4 508_SHIFT_SOLENOID_MEAS_CURRENT_SC4
- Service 22
DID D60F - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Shift-lock control 508_SHIFT_LOCK_CTRL
- Service 22
DID D701 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Start permission from gearbox computer 508_START_PERMISSION
- Service 22
DID D41A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Temperature of the nox catalytic converter 508_T_NOX_CATALYTIC_CONV
- Service 22
DID D543 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 °C
- Unit
- °C
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Torque converter lock-up pressure variation solenoid valve control current 508_TQ_CONV_LOCK_UP_P
- Service 22
DID D604 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Torque converter lock-up pressure variation solenoid valve control current 508_TQ_CONV_LOCK_UP_P_VARIATION
- Service 22
DID D605 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Torque converter slip mode, theoretical value 508_TQ_CONV_SLIP_MODE
- Service 22
DID D655 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -8128 to 8192 rpm
- Unit
- rpm
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Torque converter status 508_TQ_CONV_STAT
- Service 22
DID D504 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Upstream catalytic converter aging 508_PRE_CATALYTIC_CONV
- Service 22
DID D559 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Trips
Distance to next oil change 508_DIST_NEXT_OIL_CHANGE
- Service 22
DID D536 - Module
6A8 → 688 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Distance traveled since the last regeneration 508_DIST_TRAVELED_SINCE
- Service 22
DID D519 - Module
6A8 → 688 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4095 km
- Unit
- km
In testing for 2010 to 2012, 2014 to 2020, 2022 to 2026. Not supported for 2013, 2021.
Odometer 508_ODO_6A9
Pelican can show this parameter as the odometer.
- Service 22
DID D802 - Module
6A9 → 689 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.