Peugeot 3008

Parameters

The Peugeot 3008 has 544 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine control computer supply voltage 3008_ENG_CTRL_COMPUTER_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID D422
  • Module6A8 → 688
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 V
Unit
V

0x0568 = 1384 → 1384100.0000022 = 13.84 V

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Accelerator pedal signal 1 voltage 3008_ACCEL_PEDAL_SIG_1_VConfirmed

  • Service 22DID D405
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5000.000126
Range
-6.55 to 6.55 V
Unit
V

0x07DE = 2014 → 20145000.000126 = 0.4028 V

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Accelerator pedal signal 2 voltage 3008_ACCEL_PEDAL_SIG_2_VConfirmed

  • Service 22DID D406
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5000.000126
Range
-6.55 to 6.55 V
Unit
V

0x0407 = 1031 → 10315000.000126 = 0.2062 V

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Approximate position of turbocharger actuator 3008_APPROXIMATE_POS

  • Service 22DID D4EC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Average cell voltage value 3008_AVG_CELL_V

  • Service 22DID D43D
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery average temperature 3008_BAT_AVG_T

  • Service 22DID D877
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 001 voltage 3008_BAT_CELL_001_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 002 voltage 3008_BAT_CELL_002_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 003 voltage 3008_BAT_CELL_003_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 004 voltage 3008_BAT_CELL_004_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 005 voltage 3008_BAT_CELL_005_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 006 voltage 3008_BAT_CELL_006_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 007 voltage 3008_BAT_CELL_007_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 008 voltage 3008_BAT_CELL_008_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 009 voltage 3008_BAT_CELL_009_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 010 voltage 3008_BAT_CELL_010_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 011 voltage 3008_BAT_CELL_011_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 012 voltage 3008_BAT_CELL_012_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 013 voltage 3008_BAT_CELL_013_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 014 voltage 3008_BAT_CELL_014_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 015 voltage 3008_BAT_CELL_015_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 016 voltage 3008_BAT_CELL_016_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 017 voltage 3008_BAT_CELL_017_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 018 voltage 3008_BAT_CELL_018_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 019 voltage 3008_BAT_CELL_019_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 020 voltage 3008_BAT_CELL_020_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 021 voltage 3008_BAT_CELL_021_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 022 voltage 3008_BAT_CELL_022_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 023 voltage 3008_BAT_CELL_023_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 024 voltage 3008_BAT_CELL_024_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 025 voltage 3008_BAT_CELL_025_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 026 voltage 3008_BAT_CELL_026_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 027 voltage 3008_BAT_CELL_027_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 028 voltage 3008_BAT_CELL_028_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 029 voltage 3008_BAT_CELL_029_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 030 voltage 3008_BAT_CELL_030_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 031 voltage 3008_BAT_CELL_031_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 032 voltage 3008_BAT_CELL_032_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 033 voltage 3008_BAT_CELL_033_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 034 voltage 3008_BAT_CELL_034_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 035 voltage 3008_BAT_CELL_035_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 036 voltage 3008_BAT_CELL_036_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 037 voltage 3008_BAT_CELL_037_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 038 voltage 3008_BAT_CELL_038_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 039 voltage 3008_BAT_CELL_039_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 040 voltage 3008_BAT_CELL_040_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 041 voltage 3008_BAT_CELL_041_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 042 voltage 3008_BAT_CELL_042_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 043 voltage 3008_BAT_CELL_043_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 044 voltage 3008_BAT_CELL_044_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 045 voltage 3008_BAT_CELL_045_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 046 voltage 3008_BAT_CELL_046_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 047 voltage 3008_BAT_CELL_047_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 048 voltage 3008_BAT_CELL_048_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 049 voltage 3008_BAT_CELL_049_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 050 voltage 3008_BAT_CELL_050_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 051 voltage 3008_BAT_CELL_051_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 052 voltage 3008_BAT_CELL_052_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 053 voltage 3008_BAT_CELL_053_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 054 voltage 3008_BAT_CELL_054_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 055 voltage 3008_BAT_CELL_055_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 056 voltage 3008_BAT_CELL_056_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 057 voltage 3008_BAT_CELL_057_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 058 voltage 3008_BAT_CELL_058_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 059 voltage 3008_BAT_CELL_059_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 060 voltage 3008_BAT_CELL_060_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 061 voltage 3008_BAT_CELL_061_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 062 voltage 3008_BAT_CELL_062_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 063 voltage 3008_BAT_CELL_063_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 064 voltage 3008_BAT_CELL_064_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 065 voltage 3008_BAT_CELL_065_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 066 voltage 3008_BAT_CELL_066_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 067 voltage 3008_BAT_CELL_067_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 068 voltage 3008_BAT_CELL_068_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 069 voltage 3008_BAT_CELL_069_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 070 voltage 3008_BAT_CELL_070_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 071 voltage 3008_BAT_CELL_071_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 072 voltage 3008_BAT_CELL_072_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 073 voltage 3008_BAT_CELL_073_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 074 voltage 3008_BAT_CELL_074_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 075 voltage 3008_BAT_CELL_075_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 076 voltage 3008_BAT_CELL_076_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 077 voltage 3008_BAT_CELL_077_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 078 voltage 3008_BAT_CELL_078_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 079 voltage 3008_BAT_CELL_079_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 080 voltage 3008_BAT_CELL_080_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 081 voltage 3008_BAT_CELL_081_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 082 voltage 3008_BAT_CELL_082_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 083 voltage 3008_BAT_CELL_083_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 084 voltage 3008_BAT_CELL_084_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 085 voltage 3008_BAT_CELL_085_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 086 voltage 3008_BAT_CELL_086_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 087 voltage 3008_BAT_CELL_087_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 088 voltage 3008_BAT_CELL_088_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 089 voltage 3008_BAT_CELL_089_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 090 voltage 3008_BAT_CELL_090_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 091 voltage 3008_BAT_CELL_091_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 092 voltage 3008_BAT_CELL_092_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 093 voltage 3008_BAT_CELL_093_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 094 voltage 3008_BAT_CELL_094_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,488 to 1,503 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 095 voltage 3008_BAT_CELL_095_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,504 to 1,519 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 096 voltage 3008_BAT_CELL_096_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,520 to 1,535 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 097 voltage 3008_BAT_CELL_097_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,536 to 1,551 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 098 voltage 3008_BAT_CELL_098_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,552 to 1,567 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 099 voltage 3008_BAT_CELL_099_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,568 to 1,583 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 100 voltage 3008_BAT_CELL_100_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,584 to 1,599 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 101 voltage 3008_BAT_CELL_101_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,600 to 1,615 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 102 voltage 3008_BAT_CELL_102_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,616 to 1,631 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 103 voltage 3008_BAT_CELL_103_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,632 to 1,647 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 104 voltage 3008_BAT_CELL_104_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,648 to 1,663 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 105 voltage 3008_BAT_CELL_105_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,664 to 1,679 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 106 voltage 3008_BAT_CELL_106_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,680 to 1,695 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 107 voltage 3008_BAT_CELL_107_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,696 to 1,711 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 108 voltage 3008_BAT_CELL_108_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,712 to 1,727 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 109 voltage 3008_BAT_CELL_109_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,728 to 1,743 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 110 voltage 3008_BAT_CELL_110_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,744 to 1,759 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 111 voltage 3008_BAT_CELL_111_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,760 to 1,775 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 112 voltage 3008_BAT_CELL_112_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,776 to 1,791 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 113 voltage 3008_BAT_CELL_113_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,792 to 1,807 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 114 voltage 3008_BAT_CELL_114_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,808 to 1,823 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 115 voltage 3008_BAT_CELL_115_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,824 to 1,839 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 116 voltage 3008_BAT_CELL_116_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,840 to 1,855 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 117 voltage 3008_BAT_CELL_117_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,856 to 1,871 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 118 voltage 3008_BAT_CELL_118_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,872 to 1,887 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 119 voltage 3008_BAT_CELL_119_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,888 to 1,903 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery cell 120 voltage 3008_BAT_CELL_120_V

  • Service 22DID D440
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 1,904 to 1,919 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery current 3008_BAT_CURRENTConfirmed

  • Service 22DID D497
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1024
Range
-2097152 to 2097151 A
Unit
A

0x0000003D = 61 → 611024 = 0.05957 A

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Battery DC current 3008_BAT_DC_CURRENT

  • Service 22DID D816
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val64−1200
Range
-1200 to 67107663 A
Unit
A

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery insulation resistance 3008_BAT_INSULATION_RES

  • Service 22DID D47A
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kΩ
Unit
kΩ

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery max unit temperature 3008_BAT_MAX_UNIT_T

  • Service 22DID D817
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery max unit temperature number 3008_BAT_MAX_UNIT_T_NUMBER

  • Service 22DID D445
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery min unit temperature 3008_BAT_MIN_UNIT_T

  • Service 22DID D87D
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery min unit temperature number 3008_BAT_MIN_UNIT_T_NUMBER

  • Service 22DID D446
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Battery temperature 3008_BAT_T

  • Service 22DID D8EF
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Cell voltage sum 3008_CELL_V_SUMM

  • Service 22DID D438
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Centralized voltage maintenance device temperature limiter state 3008_CENTRALIZED_V_T

  • Service 22DID D759
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Computer power supply voltage 3008_COMPUTER_POWER_SUP_VConfirmed

  • Service 22DID D551
  • Module6A9 → 689
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x8B = 139 → 13910 = 13.9 V

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Energy accumulator discharge permission state 3008_ENERGY_ACCUMULATOR

  • Service 22DID D74F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Engine control computer supply voltage 3008_ENG_CTRL_COMPUTER_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID D422
  • Module6A8 → 688
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 V
Unit
V

0x0568 = 1384 → 1384100.0000022 = 13.84 V

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Engine oil level sensor voltage 3008_ENG_OIL_LEVEL_SENS_VConfirmed

  • Service 22DID D41E
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553 mV
Unit
mV

0x0EE2 = 3810 → 38105 = 762 mV

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Evaluation of the total resistance of the voltage maintaining device 3008_EVALUATION_TOT_RES_V

  • Service 22DID D72D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128040.9703
Range
0 to 0.511
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

High voltage battery charge 3008_HVBAT_SOC_RAW

Pelican can show this parameter as the state of charge.

  • Service 22DID D810
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 100 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

High voltage battery charge, calibrated 3008_HVBAT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID D410
  • Module6B4 → 694
  • Every1 s
  • Testing for 2008 to 2023, 2025 to 2026

Example reply from a 2024 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0512 = 0 %

Confirmed for 2024. In testing for 2008 to 2016, 2020, 2022, 2026. Not supported for 2017 to 2019, 2021, 2023, 2025.

High voltage battery health 3008_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID D860
  • Module6B4 → 694
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val16
Range
0 to 100 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

High voltage battery voltage 3008_HVBAT_VOLT

  • Service 22DID D815
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

High voltage maximum voltage 3008_HVBAT_MAX_VOLT

  • Service 22DID D870
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

High voltage minimum voltage 3008_HVBAT_MIN_VOLT

  • Service 22DID D86F
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Highest voltage cell number 3008_HIGHEST_V_CELL

  • Service 22DID D43B
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

HV battery energy 3008_HVBAT_KWH

Energy stored in the high voltage battery

  • Service 22DID D865
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 kWh
Unit
kWh

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Lowest voltage cell number 3008_LOWEST_V_CELL_NUMBER

  • Service 22DID D43C
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Maximum power the battery can provide for 10 seconds 3008_MAX_POWER_BAT_CAN_PROVIDE_10

  • Service 22DID D873
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×1953250000−500
Range
-500 to 33551784 kW
Unit
kW

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Maximum power the battery can provide for 30 seconds 3008_MAX_POWER_BAT_CAN_PROVIDE_30

  • Service 22DID D874
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×1953250000−500
Range
-500 to 33551784 kW
Unit
kW

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Maximum power the battery can withstand for 10 seconds 3008_MAX_POWER_BAT_CAN_10

  • Service 22DID D871
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×1953250000−500
Range
-500 to 33551784 kW
Unit
kW

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Maximum power the battery can withstand for 30 seconds 3008_MAX_POWER_BAT_CAN_30

  • Service 22DID D872
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×1953250000−500
Range
-500 to 33551784 kW
Unit
kW

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Minimum battery voltage at startup 3008_MIN_BAT_V_STARTUP

  • Service 22DID D4D4
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50.00000112
Range
-655 to 655 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

On-board charger temperature 3008_ON_BOARD_CHARGER_T

  • Service 22DID D8E1
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Reversible generator voltage 3008_REVERSIBLE_GEN_V

  • Service 22DID D713
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Service battery charge state 3008_SERVICE_BAT_CHG_STConfirmed

  • Service 22DID D742
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Service battery charge status 3008_SERVICE_BAT_CHG_STATConfirmed

  • Service 22DID D467
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

0x04D8 = 1240 → 124016 = 77.5 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Service battery temperature 3008_SERVICE_BAT_T

  • Service 22DID D496
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Service battery temperature 3008_SERVICE_BAT_T_6A8Confirmed

  • Service 22DID D496
  • Module6A8 → 688
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 °C
Unit
°C

0x0052 = 82 → 822 = 41 °C

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Service battery voltage 3008_SERVICE_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID D78A
  • Module6A8 → 688
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 V
Unit
V

0x06F4 = 1780 → 1780128 = 13.90625 V

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Service battery wear condition 3008_SERVICE_BAT_WEARConfirmed

  • Service 22DID D741
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Service cell voltage value 3008_SERVICE_CELL_V

  • Service 22DID D822
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Set voltage of energy storage 3008_SET_V_ENERGY_STORAGE

  • Service 22DID D734
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Set voltage of storage battery charging 3008_SET_V_STORAGE_BATConfirmed

  • Service 22DID D766
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 V
Unit
V

0x0718 = 1816 → 1816128 = 14.1875 V

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Set voltage of the reversible generator 3008_SET_V_REVERSIBLE_GEN

  • Service 22DID D712
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val39.9999994+10.60000038
Range
0 to 16.97 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Stop permitted by voltage maintainer computer 3008_STOP_PERMITTED_V

  • Service 22DID D749
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Temperature of the electronic power unit of the voltage maintenance device 3008_T_ELECTRONIC_POWER_V

  • Service 22DID D730
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Turbocharger control duty cycle 3008_TURBOCHARGER_CTRLConfirmed

  • Service 22DID D48A
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val256
Range
-128 to 127 %
Unit
%

0x391C = 14620 → 14620256 = 57.109375 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Turbocharger first electronic boost 3008_TURBOCHARGER_FIRST

  • Service 22DID D48C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Turbocharger position information 3008_TURBOCHARGER_POS

  • Service 22DID D4EA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Turbocharger pressure measured 3008_TURBOCHARGER_P_MEASConfirmed

  • Service 22DID D4D9
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

0x1162 = 4450 → 4,450

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Turbocharger pressure reference 3008_TURBOCHARGER_P

  • Service 22DID D556
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Turbocharger, target position 3008_TURBOCHARGER_TGT_POS

  • Service 22DID D47B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Voltage at the terminals of the energy accumulator 3008_V_TERMINALS_ENERGY

  • Service 22DID D720
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96 V
Unit
V

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Voltage maintainer computer request sent 3008_V_MAINTAINER_COMPUTER_REQ

  • Service 22DID D748
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Voltage maintainer computer restart permission 3008_V_MAINTAINER

  • Service 22DID D747
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Voltage maintainer status 3008_V_MAINTAINER_STAT

  • Service 22DID D72C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Climate

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Control

Anti-lock brake or stability control regulating 3008_ABS_EKS_PROCESS_ADJ

  • Service 22DID D474
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Brake circuit pressure 3008_BRAKE_CIRCUIT_P

  • Service 22DID D70E
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−55
Range
-55 to 6498 bar
Unit
bar

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Brake system backup contactor status 3008_BRAKE_SYSTEM_BACKUPConfirmed

  • Service 22DID D463
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Main brake contactor status 3008_MAIN_BRAKE_CONTACTORConfirmed

  • Service 22DID D513
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Secondary brake contactor status 3008_SECONDARY_BRAKEConfirmed

  • Service 22DID D514
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Vacuum present in the brake system 3008_VACUUM_PRESENT_BRAKEConfirmed

  • Service 22DID D700
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed

Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.

  • Service 01PID 4E
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2023. Supported for 2017 to 2019, 2021.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 4D
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2023. Supported for 2017 to 2019, 2021.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Engine

5V power supply state number 1 3008_5V_POWER_SUP_ST_1Confirmed

  • Service 22DID D423
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

5V power supply state number 2 3008_5V_POWER_SUP_ST_2Confirmed

  • Service 22DID D424
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x04 = 4 → 4

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

5V power supply state number 3 3008_5V_POWER_SUP_ST_3Confirmed

  • Service 22DID D425
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

5V power supply state number 4 3008_5V_POWER_SUP_ST_4

  • Service 22DID D426
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

12V network allowed stop 3008_12V_NETWORK_ALLOWEDConfirmed

  • Service 22DID D74C
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Activation count, brake electromagnetic valve B1 3008_NUM_ACTIVATIONS_B1Confirmed

  • Service 22DID D745
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x0004C4B9 = 312505 → 312,505

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Activation count, line pressure control solenoid 3008_NUM_LINE_P_CTRL

  • Service 22DID D751
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Activation count, the electromagnetic valve of brake B2 3008_NUM_ACTIVATIONS_B2

  • Service 22DID D75A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Actual oil pressure 3008_ACT_OIL_P

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 bar
Unit
bar

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Additional heater control 1 3008_ADDITIONAL_HEATER_1

  • Service 22DID D416
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Air conditioning 3008_ACConfirmed

  • Service 22DID D4AF
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Air conditioning compressor current 3008_AC_COMP_CURRENTConfirmed

  • Service 22DID D41C
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375
Unit
Number

0x0D = 13 → 13×25 = 325

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Air conditioning high side pressure 3008_AC_HIGH_SIDE_P

  • Service 22DID D8FF
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 bar
Unit
bar

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Air conditioning pressure 3008_AC_PConfirmed

  • Service 22DID D421
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

0x4386 = 17286 → 172861000 = 17.286 bar

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Air doser first electronic loading 3008_AIR_DOSER_FIRST

  • Service 22DID D53B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Air flow 3008_AIR_FLOWConfirmed

  • Service 22DID D489
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

0x008C = 140 → 14010 = 14

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2017, 2023. Supported for 2018 to 2019, 2021.

Air flow target 3008_AIR_FLOW_TGTConfirmed

  • Service 22DID D48E
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

0x00CA = 202 → 20210 = 20.2

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Air metering valve duty cycle 3008_AIR_METERING_VLV

  • Service 22DID D461
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Air metering valve position 3008_AIR_METERING_VLV_POS

  • Service 22DID D54F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Air metering valve, target position 3008_AIR_METERING_VLV_TGTConfirmed

  • Service 22DID D460
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

0x0940 = 2368 → 2368100.0000022 = 23.679999 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Air temperature by air flow meter 3008_AIR_T_AIR_FLOW_METER

  • Service 22DID D54E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Alternator load value 3008_ALTERNATOR_LOADConfirmed

  • Service 22DID D4A5
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x13 = 19 → 19 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Ambient air temperature 3008_AAT_6A9Confirmed

  • Service 22DID D552
  • Module6A9 → 689
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x96 = 150 → 1502−40 = 35 °C

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Ambient temperature 3008_AAT

  • Service 22DID D434
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

ANTI START PROGRAMMING STATUS 3008_ANTI_START

  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Atmospheric pressure 3008_ATMOSPHERIC_PConfirmed

  • Service 22DID D465
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

0x03E9 = 1001 → 1,001

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Automatic restart request from body control module 3008_AUTOMATIC_RESTART_REQ_BSIConfirmed

  • Service 22DID D70A
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Automatic restart request from engine management computer 3008_AUTOMATIC_RESTARTConfirmed

  • Service 22DID D709
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Automatic stop allowed by body control module 3008_AUTOMATIC_STOPConfirmed

  • Service 22DID D703
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Automatic stop allowed by power steering computer 3008_AUTOMATIC_STOP_ALLOWED_POWER_STEERConfirmed

  • Service 22DID D705
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Auxiliary heater 2 control 3008_AUXILIARY_HEATER_2

  • Service 22DID D417
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Average mileage for the last 10 regenerations 3008_AVG_MILEAGE_LAST_10

  • Service 22DID D525
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val16
Range
0 to 4095 km
Unit
km

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Boost air temperature 3008_BOOST_AIR_T

  • Service 22DID D411
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Button state 3008_BUTTON_ST

  • Service 22DID D517
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017, 2023. Supported for 2018 to 2019, 2021, 2024 to 2025.

Camshaft/crankshaft position synchronization 3008_CAM_CRANK_POS

  • Service 22DID D418
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

CHANGE REPORT IN PROGRESS 3008_CHANGE_REPORTConfirmed

  • Service 22DID D516
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Combustion engine state 3008_ICE_ST

  • Service 22DID D709
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2017 to 2019, 2021.

Commanded oil pressure 3008_CMD_OIL_P

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 bar
Unit
bar

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Computer lock 3008_COMPUTER_LOCK

  • Service 22DID DADD
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Computer remote wake-up state 3008_COMPUTER_WAKE_UP_STConfirmed

  • Service 22DID D515
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x04 = 4 → 4

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Computer restarts since memory erase 3008_CNT_NUM_RE

  • Service 22DID D4D8
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Computer temperature 3008_COMPUTER_TConfirmed

  • Service 22DID D435
  • Module6A8 → 688
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

0x0CE7 = 3303 → 3,303 °C

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Control current of electromagnetic valve for changing the pressure in the brake system B2 3008_CTRL_CURRENT_P_B2

  • Service 22DID D622
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Control current of the electromagnetic valve for changing the pressure in the brake system B1 3008_CTRL_CURRENT_P_B1Confirmed

  • Service 22DID D608
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

0x0A = 10 → 10×10 = 100 mA

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Controlled air supply module 3008_CONTROLLED_AIR_SUPConfirmed

  • Service 22DID D4A0
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Coolant temperature 3008_ECT

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID D8FB
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Coolant temperature 3008_ECT_6A8

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID D415
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Coolant temperature target 3008_ECT_TGTConfirmed

  • Service 22DID D40D
  • Module6A8 → 688
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

0x0055 = 85 → 85 °C

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Coolant temperature, corrected 3008_ECT_CORRECTEDConfirmed

  • Service 22DID D40A
  • Module6A8 → 688
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

0x0057 = 87 → 87 °C

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Cruise control, RW status 3008_CRUISE_CTRL_RW_STATConfirmed

  • Service 22DID D4B0
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x02 = 2 → 2

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Cylinder 1 injector flow correction 3008_CYL_1_INJ_FLOW_CORR

  • Service 22DID D546
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Cylinder 2 injector flow correction 3008_CYL_2_INJ_FLOW_CORR

  • Service 22DID D547
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Cylinder 3 injector flow correction 3008_CYL_3_INJ_FLOW_CORR

  • Service 22DID D548
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Cylinder 4 injector flow correction 3008_CYL_4_INJ_FLOW_CORR

  • Service 22DID D549
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Date 3008_DATEConfirmed

  • Service 22DID D4CA
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 s
Unit
s

0x02EEF35B = 49214299 → 4921429910 = 4,921,429.9 s

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Drive motor coolant inlet temperature 3008_DRIVE_MOTOR_CLT_T

  • Service 22DID D8D6
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Drive motor power 3008_DRIVE_MOTOR_POWER

  • Service 22DID D8D9
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×100
Range
-3276800 to 3276700 W
Unit
W

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Drive motor stator temperature 3008_DRIVE_MOTOR_STATOR_T

  • Service 22DID D8CD
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Drive motor torque, actual 3008_DRIVE_MOTOR_TQ_ACT

  • Service 22DID D8D0
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Drive motor torque, desired 3008_DRIVE_MOTOR_TQ_DES

  • Service 22DID D880
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 N·m
Unit
N·m

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Driver presence 3008_DRIVER_PRESENCEConfirmed

  • Service 22DID D723
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Driver, requested torque value 3008_DRIVER_REQ_TQConfirmed

  • Service 22DID D507
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

0x23 = 35 → 35×2−100 = -30 N·m

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Economy mode off state 3008_ECO_MODE_OFF_STConfirmed

  • Service 22DID D724
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

EGR error EGR_ERRSAE J1979Confirmed

  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2023. Supported for 2017 to 2019, 2021.

Electric cooling fan control 3008_GMV_ELEC_COOLING_FANConfirmed

  • Service 22DID D42F
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Electric machine torque 3008_ELEC_MACHINE_TQ

  • Service 22DID DCB6
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−1638.3
Range
-1638 to 4915 N·m
Unit
N·m

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Electric machine torque reduction 3008_ELEC_MACHINE_TQ_REDUCTION

  • Service 22DID DC69
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Energy accumulator state transfer 3008_ENERGY_ACCUMULATOR_ST

  • Service 22DID D755
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Energy accumulator temperature limiter state 3008_ENERGY_ACCUMULATOR_T

  • Service 22DID D758
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Engine control module status 3008_ENG_CTRL_MODULE_STATConfirmed

  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Engine coolant temperature 3008_ECT_6A9Confirmed

  • Service 22DID D555
  • Module6A9 → 689
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x7E = 126 → 126−40 = 86 °C

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Engine oil dilution protection status 3008_ENG_OIL_DILUTION

  • Service 22DID D524
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Engine operating mode 3008_ENG_OP_MODEConfirmed

  • Service 22DID D553
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 rpm
Unit
rpm

0x18C8 = 6344 → 63448 = 793 rpm

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Engine restart counter 3008_ENG_RESTART_CNT

  • Service 22DID D406
  • Module6A9 → 689
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Engine restart counter by stop and start function 3008_ENG_RESTART_CNT_STOP

  • Service 22DID D71B
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Engine restart request sent by ESP computer 3008_ENG_RESTART_REQ_SENTConfirmed

  • Service 22DID D70D
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Engine stalls 3008_ENG_STALLSConfirmed

  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Engine start prohibition control, start lock 3008_ENG_STARTConfirmed

  • Service 22DID D703
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Engine stop time 3008_ENG_STOP_TIMEConfirmed

  • Service 22DID D477
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

0x000066EA = 26346 → 26,346 s

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Engine torque 3008_ENG_TQ

  • Service 21PID C3
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Estimated torque of internal friction of the engine 3008_ESTIMATED_TQConfirmed

  • Service 22DID D4E2
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 N·m
Unit
N·m

0x0100 = 256 → 25616 = 16 N·m

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Evaluation of carbon content in engine oil 3008_EVALUATION_CARBON

  • Service 22DID D523
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val32
Range
0 to 7.96 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Evaluation of the degree of dilution of motor oil 3008_EVALUATION_DEGREE

  • Service 22DID D51F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Exhaust gas recirculation high limit electronic loading 3008_EGR_HIGH_LIM

  • Service 22DID D553
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Exhaust gas recirculation low limit electronic loading 3008_EGR_LOW_LIM

  • Service 22DID D552
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Exhaust gas recirculation valve duty cycle 3008_EGR_VLV_CTRL_SIG_RCO

  • Service 22DID D511
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Exhaust gas recirculation valve first electronic loading 3008_EGR_VLV_FIRST

  • Service 22DID D53A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Exhaust gas recirculation valve position 3008_EGR_VLV_POS

  • Service 22DID D509
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Exhaust gas recirculation valve set position 3008_EGR_VLV_SET_POS

  • Service 22DID D510
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Expected generator supplier identifier of the reversible generator 3008_EXPECTED_GEN

  • Service 22DID D789
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Expected identifier of electronic power circuit of reversible generator generator 3008_EXPECTED_IDENTIFIER_ELECTRONIC

  • Service 22DID D788
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Expected identifier of reversible generator 3008_EXPECTED_IDENTIFIER

  • Service 22DID D787
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

FUGITIVE TRIP IN EMERGENCY MODE 3008_FUGITIVE_TRIPConfirmed

  • Service 22DID D671
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Generator mode 3008_GEN_MODE

  • Service 22DID D714
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×75
Range
0 to 19125 rpm
Unit
rpm

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Generator shutdown 3008_GEN_SHUTDOWN

  • Service 22DID D75B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Identifier of the electronic power circuit of the reversible generator 3008_IDENTIFIER

  • Service 22DID D732
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Identifier of the supplier of the reversible generator 3008_IDENTIFIER_SUPPLIER

  • Service 22DID D733
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Immobilizer code programming status 3008_IMMOBILIZER_CODEConfirmed

  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x04 = 4 → 4

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Indicated engine torque 3008_INDICATED_ENG_TQConfirmed

  • Service 22DID D4D2
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 N·m
Unit
N·m

0x0000 = 0 → 016 = 0 N·m

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Injector code 1 3008_INJ_CODE_1

  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 8 to 47 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Injector code 2 3008_INJ_CODE_2

  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 72 to 111 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Injector code 3 3008_INJ_CODE_3

  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 136 to 175 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Injector code 4 3008_INJ_CODE_4

  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 200 to 239 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Inverter temperature estimated 3008_INVERTER_T_ESTIMATED

  • Service 22DID DC6A
  • Module6A6 → 686
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Inverter temperature, commanded 3008_INVERTER_T_CMD

  • Service 22DID DC04
  • Module6A6 → 686
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Line pressure solenoid valve control current 3008_SLT_LINE_P_VARIATIONConfirmed

  • Service 22DID D606
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

0x4A = 74 → 74×10 = 740 mA

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Lock status 3008_LOCK_STATConfirmed

  • Service 22DID DADD
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Long-term regeneration capability 3008_LONG_TERM_REGEN

  • Service 22DID D54D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Maximum allowable torque 3008_MAX_ALLOWABLE_TQConfirmed

  • Service 22DID D506
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

0x34 = 52 → 52×2−100 = 4 N·m

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Measured current of electromagnetic valve for changing the pressure in the brake system B2 3008_MEAS_CURRENT_P_B2

  • Service 22DID D623
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Measured current of the electromagnetic valve for changing the pressure in the brake system B1 3008_MEAS_CURRENT_P_B1Confirmed

  • Service 22DID D609
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

0x09 = 9 → 9×10 = 90 mA

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Measured line pressure variation solenoid valve current 3008_MEAS_LINE_PConfirmed

  • Service 22DID D607
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

0x49 = 73 → 73×10 = 730 mA

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Mileage since last oil change 3008_MILEAGE_SINCE_OIL

  • Service 22DID D43F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Minimum cell capacity 3008_MIN_CELL_CAP

  • Service 22DID D413
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Movement of controlled air supply module 3008_MOVEMENT_CONTROLLED

  • Service 22DID D4EB
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Neutral position sensor status 3008_NEUTRAL_POS_SENSConfirmed

  • Service 22DID D438
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Number of engine stop information deletion cycles 3008_NUM_ENG_STOPConfirmed

  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Oil pressure 3008_OIL_PConfirmed

  • Service 22DID D429
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

0x0169 = 361 → 3611000 = 0.361 bar

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Oil pressure reference value 3008_OIL_P_REFERENCEConfirmed

  • Service 22DID D464
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

0x0A4A = 2634 → 26341000 = 2.634 bar

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Oil pressure regulation control 3008_OIL_P_REGULATION

  • Service 22DID D43B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Oil temperature 3008_OIL_TConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID D47D
  • Module6A8 → 688
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

0x03B8 = 952 → 95210−273.1400146 = -177.940015 °C

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Outside air temperature 3008_AAT_6A8Confirmed

  • Service 22DID D414
  • Module6A8 → 688
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

0x0022 = 34 → 34 °C

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Powertrain condition 3008_POWERTRAIN_CONDConfirmed

  • Service 22DID D4BA
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Preheating relay control 3008_PREHEATING_RELAY

  • Service 22DID D50C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Presence of the identifier of the reversible generator 3008_PRESENCE_IDENTIFIER

  • Service 22DID D731
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Problems detected while transmitting unlock code 3008_PROBLEMS_DETECTEDConfirmed

  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Problems detected while transmitting unlock code 3008_PROBLEMS_DETECTED_WHILE

  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Real engine torque 3008_REAL_ENG_TQConfirmed

  • Service 22DID D554
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

0x24 = 36 → 36×2−100 = -28 N·m

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Regeneration enable 3008_REGEN_ENABLE

  • Service 22DID D528
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Remote wake-up circuit status 3008_REMOTE_WAKE_UPConfirmed

  • Service 22DID D705
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Remote wake-up state 3008_REMOTE_WAKE_UP_ST

  • Service 22DID D708
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Request to turn on the engine diagnostic indicator 3008_REQ_TURN_ON_ENGConfirmed

  • Service 22DID D511
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Requested value controlled thermostat 3008_REQ_CONTROLLED

  • Service 22DID D586
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val81.92000625
Range
-399 to 399 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Restart request sent by power steering computer 3008_RESTART_REQ_SENTConfirmed

  • Service 22DID D70C
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Restart request sent by suspension computer 3008_RESTART_REQ_SENT_SUSPENSIONConfirmed

  • Service 22DID D70E
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Return to engine start and restart control by starter 3008_RETURN_ENG_STARTConfirmed

  • Service 22DID D764
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x02 = 2 → 2

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Return to starter engine restart control 3008_RETURN_STARTER_ENGConfirmed

  • Service 22DID D761
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x02 = 2 → 2

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Reverse generator status 3008_REVERSE_GEN_STAT

  • Service 22DID D716
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Reversible generator torque 3008_REVERSIBLE_GEN_TQ

  • Service 22DID D715
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Service network related engine restart request 3008_SERVICE_NETWORKConfirmed

  • Service 22DID D74B
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x04 = 4 → 4

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Short-term regeneration capability 3008_SHORT_TERM_REGEN

  • Service 22DID D54C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Sport mode contactor state 3008_SPORT_MODE_CONTACTORConfirmed

  • Service 22DID D503
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Start inhibit control, wired 3008_START_INHIBIT_CTRLConfirmed

  • Service 22DID D767
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Start or restart inhibition transmitted by engine management computer 3008_START_OR_RESTARTConfirmed

  • Service 22DID D71E
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Start prohibition 3008_START_PROHIBITIONConfirmed

  • Service 22DID D51B
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Starter activation counter 3008_STARTER_ACTIVATIONConfirmed

  • Service 22DID D71F
  • Module6A8 → 688
  • Every3600 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x000032BE = 12990 → 12,990

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Starter control interface unit operating status 3008_STARTER_CTRLConfirmed

  • Service 22DID D72A
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Starter duty cycle 3008_STARTER_DUTYConfirmed

  • Service 22DID D478
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 s
Unit
s

0x0000 = 0 → 010 = 0 s

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Starter engagement status 3008_STARTER_ENGAGEMENTConfirmed

  • Service 22DID D4C3
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

State lock/unlock control unit 3008_ST_LOCK_UNLOCK_CTRL

  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Status of internal ignition motor 3008_STAT_INTERNAL_IGNConfirmed

  • Service 22DID D412
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x05 = 5 → 5

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Status of the energy accumulator 3008_STAT_ENERGY

  • Service 22DID D722
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Stop allowed by ESP computer 3008_STOP_ALLOWED_ESPConfirmed

  • Service 22DID D706
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Stop and start function state 3008_STOP_START_FUNCTIONConfirmed

  • Service 22DID D725
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x09 = 9 → 9

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Stop and start switch 3008_STOP_START_SWITCHConfirmed

  • Service 22DID D726
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Stop permitted by suspension computer 3008_STOP_PERMITTEDConfirmed

  • Service 22DID D707
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Temperature difference between the hottest and the coolest cells 3008_T_DIFF_HOTEST

  • Service 22DID D878
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Temperature of the energy accumulator 3008_T_ENERGY_ACCUMULATOR

  • Service 22DID D721
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

The composition of the mixture is calculated by the oxygen sensor 3008_COMPOSITION_MIXTURE

  • Service 22DID D570
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32786.88588
Range
0 to 1.99
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Torque corresponding to driver requirement 3008_TQ_CORRESPONDINGConfirmed

  • Service 22DID D4E3
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

0x0096 = 150 → 15016 = 9.375 N·m

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Torque supplied or taken by generator 3008_TQ_SUPPLIED_OR_TAKENConfirmed

  • Service 22DID D728
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 N·m
Unit
N·m

0x005B = 91 → 9116 = 5.6875 N·m

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Total mileage 3008_ODO_6A8Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

0x00037BA0 = 228256 → 228,256 km

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Towing device configured 3008_CAN_VEH_BE_EQUIPPED

  • Service 22DID D557
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Traction circuit coolant temperature 3008_TRACTION_CIRCUIT_ECT

  • Service 22DID D8F9
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Traction or stability control regulating 3008_ASR_OR_ESP_SYSTEMConfirmed

  • Service 22DID D512
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Transmission fluid temperature 3008_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2023. Supported for 2018 to 2019, 2021, 2025.

Vacuum circuit vacuum 3008_VACUUM_CIRCUIT

  • Service 22DID D73B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Value during generator load smooth increase 3008_DURING_GEN_LOADConfirmed

  • Service 22DID D753
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x07 = 7 → 7

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Vehicle hour meter 3008_VEH_HOUR_METERConfirmed

  • Service 22DID D801
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 s
Unit
s

0x02EEF3DD = 49214429 → 4921442910 = 4,921,442.9 s

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Vehicle mileage since the last oil change under severe vehicle operating conditions 3008_VEH_MILEAGE_SINCE

  • Service 22DID D534
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km
Unit
km

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Winter mode switch state 3008_WINTER_MODE_SWITCHConfirmed

  • Service 22DID D502
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Fuel

Amount of fuel additive remaining in the additive tank 3008_AMOUNT_FUEL_ADDITIVE

  • Service 22DID D56C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Raw value

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Calculated fuel injection amount 3008_CALC_FUEL_INJ_AMOUNT

  • Service 22DID D563
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Raw value

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Desired high pressure common rail fuel pressure 3008_DES_HIGH_P_COMMON_PConfirmed

  • Service 22DID D445
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 bar
Unit
bar

0x0320 = 800 → 800 bar

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

First fuel additive injection state 3008_FIRST_FUEL_ADDITIVE

  • Service 22DID D56F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Fuel pressure 3008_FUEL_P

  • Service 22DID D41F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val999.9999525
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Fuel temperature 3008_FUEL_T

  • Service 22DID D42A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.14
Range
-273 to 6280 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

High fuel pressure measured 3008_HIGH_FUEL_P_MEASConfirmed

  • Service 22DID D446
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 bar
Unit
bar

0x031E = 798 → 79810 = 79.8 bar

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Injection angle of the high-pressure fuel pump 3008_INJ_ANG_HIGH_P_FUEL

  • Service 22DID D588
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Low pressure fuel pump actuator duty cycle 3008_LOW_P_FUEL_PMPConfirmed

  • Service 22DID D472
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100.0000022
Range
-327 to 327 %
Unit
%

0x0015 = 21 → 21100.0000022 = 0.21 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Low pressure fuel pump status 3008_LOW_P_FUEL_PMP_STAT

  • Service 22DID D4ED
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Minimum fuel level 3008_MIN_FLI

  • Service 22DID D56A
  • Module6A8 → 688
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Movement

Accelerator pedal position 3008_ACCEL_PEDAL_POS

  • Service 21PID C3
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×39100
Range
0 to 99.45 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Accelerator pedal position 3008_ACCEL_PEDAL_POS_6A6

  • Service 22DID D407
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Accelerator pedal position 3008_ACCEL_PEDAL_POS_6A9Confirmed

  • Service 22DID D505
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Accelerator pedal position 3008_ACCEL_PEDAL_POS_6B4

  • Service 22DID D407
  • Module6B4 → 694
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Accelerator pedal position, recalculated 3008_ACCEL_PEDAL_POS_RECALCULATEDConfirmed

  • Service 22DID D407
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 %
Unit
%

0x0000 = 0 → 0128 = 0 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Accelerator pedal position, track 1 3008_ACCEL_PEDAL_POS_1Confirmed

  • Service 22DID D491
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val81.92000625
Range
-399 to 399 %
Unit
%

0x0000 = 0 → 081.92000625 = 0 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Accelerator pedal position, track 2 3008_ACCEL_PEDAL_POS_2Confirmed

  • Service 22DID D492
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val81.92000625
Range
-399 to 399 %
Unit
%

0x0000 = 0 → 081.92000625 = 0 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Clutch release state at stop, creep speed reduction 3008_CLU_RELEASE_ST_STOPConfirmed

  • Service 22DID D672
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Crankshaft speed 3008_CRANK_SPD

  • Service 22DID D462
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 rpm
Unit
rpm

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Crankshaft speed determined by camshaft sensor 3008_CRANK_SPD_DETERMINEDConfirmed

  • Service 22DID D499
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

0x0631 = 1585 → 15852 = 792.5 rpm

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Cruise control set speed 3008_CRUISE_CTRL_SET_SPDConfirmed

  • Service 22DID D475
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Engine RPM 3008_RPMConfirmed

Pelican can show this parameter as the engine speed.

  • Service 22DID D400
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0319 = 793 → 793 rpm

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Engine RPM 3008_RPM_6A9

Pelican can show this parameter as the engine speed.

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Input shaft speed 3008_INPUT_SHFT_SPD

  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Motor speed 3008_MOTOR_SPD

  • Service 22DID DC00
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Set speed of electric cooling fan 3008_SET_SPD_ELEC_COOLINGConfirmed

  • Service 22DID D4AA
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x13 = 19 → 19 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

STATUS COMMANDS REGULATION OR LIMITATION SPEED 3008_STAT_COMMANDSConfirmed

  • Service 22DID D704
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x03 = 3 → 3

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Torque converter slip speed, measured 3008_TQ_CONV_SLIP_SPDConfirmed

  • Service 22DID D654
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×64−8128
Range
-8128 to 8192 rpm
Unit
rpm

0x7E = 126 → 126×64−8128 = -64 rpm

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Vehicle speed 3008_VSS

Pelican can show this parameter as the speed.

  • Service 21PID C8
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Vehicle speed 3008_VSS_6A2

Pelican can show this parameter as the speed.

  • Service 22DID D402
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Vehicle speed 3008_VSS_6A8Confirmed

Pelican can show this parameter as the speed.

  • Service 22DID D402
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511 km/h
Unit
km/h

0x0000 = 0 → 0128 = 0 km/h

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Vehicle speed 3008_VSS_6A9

Pelican can show this parameter as the speed.

  • Service 22DID D711
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Vehicle speed 3008_VSS_6B4

Pelican can show this parameter as the speed.

  • Service 22DID D802
  • Module6B4 → 694
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×6465535
Range
0 to 4194368 km/h
Unit
km/h

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2017, 2023. Supported for 2018 to 2019, 2021, 2024 to 2025.

Vehicle speed limiter set speed 3008_VSS_LIMITER_SET_SPDConfirmed

  • Service 22DID D476
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Vehicle speed limiter status, LW 3008_VSS_LIMITER_STAT_LWConfirmed

  • Service 22DID D4C0
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x03 = 3 → 3

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Vehicle speed, ESP 3008_VSS_ESP

Pelican can show this parameter as the speed.

  • Service 22DID D802
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1953250000
Range
0 to 511 km/h
Unit
km/h

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2023. Supported for 2017 to 2019, 2021, 2024 to 2025.

Tires

Average front wheel speed 3008_AVG_FRONT_WHL_SPDConfirmed

  • Service 22DID D530
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val25.00000056
Range
0 to 2621 rpm
Unit
rpm

0x0000 = 0 → 025.00000056 = 0 rpm

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Average speed front wheels 3008_AVG_SPD_FRONT_WHEELSConfirmed

  • Service 22DID D533
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 km/h
Unit
km/h

0x0000 = 0 → 0100.0000022 = 0 km/h

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Counter of occurrence of enhanced resonance of the twin flywheel of the engine 3008_CNT_OCCURRENCE

  • Service 22DID D4E4
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Counter of occurrence of resonance of the twin flywheel of the engine 3008_CNT_OCCURRENCE_RESONANCE

  • Service 22DID D4E5
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Rear left wheel speed 3008_RL_WHL_SPDConfirmed

  • Service 22DID D531
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 km/h
Unit
km/h

0x0000 = 0 → 0100.0000022 = 0 km/h

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Rear right wheel speed 3008_RR_WHL_SPDConfirmed

  • Service 22DID D532
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100.0000022
Range
0 to 655 km/h
Unit
km/h

0x0000 = 0 → 0100.0000022 = 0 km/h

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Transmission

Activation count, additional oil pump, ATN8 gearbox 3008_NUM_ADDITIONAL_OILConfirmed

  • Service 22DID D750
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00000000 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Activation count, clutch electromagnetic valve C2 3008_NUM_ACTIVATIONS_CLU_ELECTROMAGNETIC_VLV_C2Confirmed

  • Service 22DID D743
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x0001FD13 = 130323 → 130,323

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Activation count, clutch electromagnetic valve C3 3008_NUM_ACTIVATIONS_CLU_C3Confirmed

  • Service 22DID D744
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x0006ED16 = 453910 → 453,910

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Activation count, clutch protection C1 3008_NUM_ACTIVATIONS_CLU_C1Confirmed

  • Service 22DID D731
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Activation count, clutch protection C2 3008_NUM_ACTIVATIONS_CLU_C2Confirmed

  • Service 22DID D731
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Activation count, gear 7 3008_NUM_ACTIVATIONS_GEAR_7

  • Service 22DID D75B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Activation count, shift solenoid SC2 3008_NUM_SHIFT_SOLENOID

  • Service 22DID D752
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Activation count, shift solenoid SC3 3008_NUM_SHIFT_SOLENOID_ACTIVATIONS_SC3

  • Service 22DID D753
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Activation count, the electromagnetic valve for controlling the automatic transmission locking finger in position p 3008_NUM_ACTIVATIONS_P

  • Service 22DID D758
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Activation count, the electromagnetic valve of clutch C4 3008_NUM_ACTIVATIONS_C4

  • Service 22DID D759
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Activation count, the electromagnetic valve of the clutch C1 3008_NUM_ACTIVATIONS_C1Confirmed

  • Service 22DID D742
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00034839 = 215097 → 215,097

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Activation count, torque converter lockup electromagnetic valve 3008_NUM_ACTIVATIONS_TQConfirmed

  • Service 22DID D746
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x0004D870 = 317552 → 317,552

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Activation of additional oil pump, ATN8 gearbox 3008_ACTIVATIONConfirmed

  • Service 22DID D616
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Additional oil pump control status, atn8 transmission 3008_ADDITIONAL_OIL_PMPConfirmed

  • Service 22DID D617
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Automatic restart request from transmission computer 3008_AUTOMATIC_RESTART_REQConfirmed

  • Service 22DID D70B
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Automatic stop allowed by gearbox computer 3008_AUTOMATIC_STOP_ALLOWEDConfirmed

  • Service 22DID D704
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Automatic transmission fluid temperature 3008_AUTOMATIC_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID D550
  • Module6A9 → 689
  • Every5 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x75 = 117 → 117−40 = 77 °C

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Automatic transmission in emergency mode 3008_AUTOMATIC_TRANS_EMERGENCYConfirmed

  • Service 22DID D670
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Automatic transmission in park position 3008_AUTOMATIC_TRANS_PARK

  • Service 22DID D70B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Automatic transmission input shaft mode, calculated 3008_AUTOMATIC_TRANS_INPUT_SHFT_MODE

  • Service 22DID D651
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070 rpm
Unit
rpm

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Automatic transmission input shaft mode, measured 3008_AUTOMATIC_TRANS_INPUT_SHFT

  • Service 22DID D650
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2
Range
0 to 131070 rpm
Unit
rpm

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Automatic transmission lubrication solenoid control current 3008_AUTOMATIC_TRANS_LUBRICATION

  • Service 22DID D61A
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Automatic transmission oil aging sensor 3008_AUTOMATIC_TRANS_OILConfirmed

  • Service 22DID D405
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00006470 = 25712 → 25,712

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Automatic transmission oil drain 3008_DRAIN_TRANSConfirmed

  • Service 22DID D509
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Automatic transmission output shaft mode, calculated 3008_AUTOMATIC_TRANS_OUTPUT_SHFT_MODE

  • Service 22DID D653
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×64−8128
Range
-8128 to 4186112 rpm
Unit
rpm

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Automatic transmission output shaft mode, measured 3008_AUTOMATIC_TRANS_OUTPUT

  • Service 22DID D652
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Automatic transmission overheat indicator request 3008_AUTOMATIC_TRANSConfirmed

  • Service 22DID D510
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Automatic transmission torque request 3008_AUTOMATIC_TRANS_TQConfirmed

  • Service 22DID D508
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2−100
Range
-100 to 410 N·m
Unit
N·m

0xFE = 254 → 254×2−100 = 408 N·m

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Calculated gear in gearbox 3008_CALC_GEAR_GEARBOXConfirmed

  • Service 22DID D409
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Clutch pedal 3008_CLU_PEDALConfirmed

  • Service 22DID D404
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Clutch pedal position value 3008_CLU_PEDAL_POSConfirmed

  • Service 22DID D469
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

0x0000 = 0 → 010 = 0 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Control current of electromagnetic valve for regulating the pressure in the control system of the oil pressure accumulator, AMN8 gearbox 3008_CTRL_CURRENT_P_P

  • Service 22DID D625
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Control current of electromagnetic valve of actuator of automatic transmission lock-up in position p 3008_CTRL_CURRENT_ELECTROMAGNETIC_VLV_P

  • Service 22DID D61E
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Control current of electromagnetic valve of change of pressure of torque converter lock-up 3008_CTRL_CURRENT_P

  • Service 22DID D61C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Control current of the electromagnetic valve for changing the gear shift SC2 3008_CTRL_CURRENT

  • Service 22DID D60A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Control current of the electromagnetic valve of change of pressure of clutch C3 3008_CTRL_CURRENT_P_C3Confirmed

  • Service 22DID D614
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

0x0A = 10 → 10×10 = 100 mA

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Control current of the electromagnetic valve of change of pressure of clutch C4 3008_CTRL_CURRENT_P_C4

  • Service 22DID D620
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Control current of the solenoid valve for changing the pressure of the clutch C1 3008_CTRL_CURRENT_P_C1Confirmed

  • Service 22DID D610
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

0x0A = 10 → 10×10 = 100 mA

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Control current of the solenoid valve for changing the pressure of the clutch C2 3008_CTRL_CURRENT_P_C2Confirmed

  • Service 22DID D612
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

0x0A = 10 → 10×10 = 100 mA

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

DC-DC converter temperature 3008_DC_DC_CONV_T

  • Service 22DID D8CE
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Engaged gear 3008_ENGAGED_GEARConfirmed

  • Service 22DID D43D
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Engaged gear 3008_ENGAGED_GEAR_6A9Confirmed

  • Service 22DID D501
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Exhaust gas temperature after upstream catalytic converter 3008_EXH_GAS_T_AFTER_PRE

  • Service 22DID D555
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Exhaust gas temperature before upstream catalytic converter 3008_EXH_GAS_T_BEFORE_PRE

  • Service 22DID D52E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−273.1400146
Range
-3549 to 3003 °C
Unit
°C

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Gear in the process of engaging 3008_GEAR_PROCESSConfirmed

  • Service 22DID D43E
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Gear shift knob under steering wheel 3008_GEAR_SHIFT_KNOBConfirmed

  • Service 22DID D520
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Gear shift lever position displayed on instrument panel 3008_GEAR_SHIFT_LEVER_POS_ONConfirmed

  • Service 22DID D500
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x03 = 3 → 3

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Maximum clutch travel during gear shift 3008_MAX_CLU_TRAVELConfirmed

  • Service 22DID D498
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

0x0000 = 0 → 016 = 0 %

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Measured current of control of electromagnetic valve of automatic transmission lubrication 3008_MEAS_CURRENT_CTRL

  • Service 22DID D61B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Measured current of control of electromagnetic valve of change of pressure of torque converter lock-up 3008_MEAS_CURRENT_CTRL_P

  • Service 22DID D61D
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Measured current of the electromagnetic valve for changing the gear shift SC2 3008_MEAS_CURRENT

  • Service 22DID D60B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Measured current of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 3008_MEAS_CURRENT_P_P

  • Service 22DID D626
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Measured current of the electromagnetic valve of change of pressure of clutch C3 3008_MEAS_CURRENT_P_C3Confirmed

  • Service 22DID D615
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

0x0A = 10 → 10×10 = 100 mA

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Measured current of the electromagnetic valve of change of pressure of clutch C4 3008_MEAS_CURRENT_P_C4

  • Service 22DID D621
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Measured current of the solenoid valve for changing the pressure of the clutch C1 3008_MEAS_CURRENT_P_C1Confirmed

  • Service 22DID D611
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

0x09 = 9 → 9×10 = 90 mA

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Measured current of the solenoid valve for changing the pressure of the clutch C2 3008_MEAS_CURRENT_P_C2Confirmed

  • Service 22DID D613
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

0x09 = 9 → 9×10 = 90 mA

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Measured current of the solenoid valve for controlling the locking finger of the automatic transmission in position p 3008_MEAS_CURRENT_P

  • Service 22DID D61F
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Nitrogen oxide content after catalytic converter, ppm 3008_NOX_CONTENT_AFTER

  • Service 22DID D53D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 3008_NOX_CONTENT_MEAS

  • Service 22DID D545
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276 to 3276
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 3008_NOX_CONTENT_MEAS_INLET_NOX

  • Service 22DID D576
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Number of engagements of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 3008_NUM_ENGAGEMENTS_P_P

  • Service 22DID D75D
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Number of gear engagements 1 3008_NUM_GEAR_ENGAGEMENTS_1Confirmed

  • Service 22DID D747
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x0001EB3A = 125754 → 125,754

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Number of gear engagements 2 3008_NUM_GEAR_ENGAGEMENTS_2Confirmed

  • Service 22DID D748
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x0004027A = 262778 → 262,778

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Number of gear engagements 3 3008_NUM_GEAR_ENGAGEMENTS_3Confirmed

  • Service 22DID D749
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00046598 = 288152 → 288,152

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Number of gear engagements 4 3008_NUM_GEAR_ENGAGEMENTS_4Confirmed

  • Service 22DID D74A
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x0003680C = 223244 → 223,244

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Number of gear engagements 5 3008_NUM_GEAR_ENGAGEMENTS_5Confirmed

  • Service 22DID D74B
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00022BAA = 142250 → 142,250

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Number of gear engagements 6 3008_NUM_GEAR_ENGAGEMENTS_6Confirmed

  • Service 22DID D74C
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x0000C277 = 49783 → 49,783

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Number of gear engagements 8 3008_NUM_GEAR_ENGAGEMENTS_8

  • Service 22DID D75C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Number of gear engagements n 3008_NUM_GEAR_ENGAGEMENTS_NConfirmed

  • Service 22DID D74E
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x0000F06A = 61546 → 61,546

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Number of gear engagements right 3008_NUM_GEAR_ENGAGEMENTSConfirmed

  • Service 22DID D74D
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x0000D28E = 53902 → 53,902

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Number of shift solenoid operated automatic transmission lubrication control valve 3008_NUM_SHIFT_SOLENOID_OPERATED

  • Service 22DID D756
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Number of shift solenoid operated SC4 3008_NUM_SHIFT_SOLENOID_OPERATED_SC4

  • Service 22DID D754
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Number of shift solenoid operated SC5 3008_NUM_SHIFT_SOLENOID_OPERATED_SC5

  • Service 22DID D755
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Number of shift solenoid operated torque converter lock-up pressure regulating valve 3008_NUM_SHIFT_SOLENOID_P

  • Service 22DID D757
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Operating mode used by the automatic transmission 3008_OP_MODE_USEDConfirmed

  • Service 22DID D673
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x0D = 13 → 13

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Position of the gearshift lever 3008_POS_GEARSHIFT_LEVERConfirmed

  • Service 22DID D700
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x03 = 3 → 3

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Proportional clutch pedal sensor 3008_PROPORTIONAL_CLU

  • Service 22DID D56E
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Reverse gear contactor status 3008_REVERSE_GEARConfirmed

  • Service 22DID D43C
  • Module6A8 → 688
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

SC5 shift solenoid control current 3008_SC5_SHIFT_SOLENOID

  • Service 22DID D618
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

SC5 shift solenoid measured current 3008_SC5_SHIFT_SOLENOID_MEAS

  • Service 22DID D619
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Shift solenoid control current SC3 3008_SHIFT_SOLENOID_CTRL

  • Service 22DID D60C
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Shift solenoid control current SC4 3008_SHIFT_SOLENOID_CTRL_CURRENT_SC4

  • Service 22DID D60E
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Shift solenoid measured current SC3 3008_SHIFT_SOLENOID_MEAS

  • Service 22DID D60D
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Shift solenoid measured current SC4 3008_SHIFT_SOLENOID_MEAS_CURRENT_SC4

  • Service 22DID D60F
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Shift-lock control 3008_SHIFT_LOCK_CTRLConfirmed

  • Service 22DID D701
  • Module6A9 → 689
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Start permission from gearbox computer 3008_START_PERMISSIONConfirmed

  • Service 22DID D41A
  • Module6A8 → 688
  • Every1 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Torque converter lock-up pressure variation solenoid valve control current 3008_TQ_CONV_LOCK_UP_PConfirmed

  • Service 22DID D604
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

0x0A = 10 → 10×10 = 100 mA

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Torque converter lock-up pressure variation solenoid valve control current 3008_TQ_CONV_LOCK_UP_P_VARIATIONConfirmed

  • Service 22DID D605
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 mA
Unit
mA

0x09 = 9 → 9×10 = 90 mA

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Torque converter slip mode, theoretical value 3008_TQ_CONV_SLIP_MODEConfirmed

  • Service 22DID D655
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×64−8128
Range
-8128 to 8192 rpm
Unit
rpm

0x7F = 127 → 127×64−8128 = 0 rpm

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Torque converter status 3008_TQ_CONV_STATConfirmed

  • Service 22DID D504
  • Module6A9 → 689
  • Every250 ms
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Upstream catalytic converter aging 3008_PRE_CATALYTIC_CONV

  • Service 22DID D559
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 %
Unit
%

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Trips

Distance to next oil change 3008_DIST_NEXT_OIL_CHANGE

  • Service 22DID D536
  • Module6A8 → 688
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Distance traveled since the last regeneration 3008_DIST_TRAVELED_SINCE

  • Service 22DID D519
  • Module6A8 → 688
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val16
Range
0 to 4095 km
Unit
km

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Odometer 3008_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Odometer 3008_ODO_6A2

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6A2 → 682
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Odometer 3008_ODO_6A6

Pelican can show this parameter as the odometer.

  • Service 22DID D49C
  • Module6A6 → 686
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 km
Unit
km

In testing for 2008 to 2018, 2020 to 2026. Not supported for 2019.

Odometer 3008_ODO_6A9Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID D802
  • Module6A9 → 689
  • Every30 s
  • Testing for 2008 to 2018, 2020 to 2026

Example reply from a 2019 Peugeot 3008.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x037BA1 = 228257 → 228,257 km

Confirmed for 2019. In testing for 2008 to 2018, 2020 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.