Parameters
The Peugeot 2008 has 576 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Accelerator pedal signal 1 voltage 2008_ACCEL_PEDAL_SIG_1_V
- Service 22
DID D405 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6.55 to 6.55 V
- Unit
- V
In testing for 2013 to 2026.
Accelerator pedal signal 2 voltage 2008_ACCEL_PEDAL_SIG_2_V
- Service 22
DID D406 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6.55 to 6.55 V
- Unit
- V
In testing for 2013 to 2026.
Approximate position of turbocharger actuator 2008_APPROXIMATE_POS
- Service 22
DID D4EC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 %
- Unit
- %
In testing for 2013 to 2026.
Average cell voltage value 2008_AVG_CELL_V
- Service 22
DID D43D - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery average temperature 2008_BAT_AVG_T
- Service 22
DID D877 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2026.
Battery cell 001 voltage 2008_BAT_CELL_001_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 002 voltage 2008_BAT_CELL_002_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 003 voltage 2008_BAT_CELL_003_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 004 voltage 2008_BAT_CELL_004_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 005 voltage 2008_BAT_CELL_005_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 006 voltage 2008_BAT_CELL_006_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 007 voltage 2008_BAT_CELL_007_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 008 voltage 2008_BAT_CELL_008_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 009 voltage 2008_BAT_CELL_009_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 010 voltage 2008_BAT_CELL_010_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 011 voltage 2008_BAT_CELL_011_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 012 voltage 2008_BAT_CELL_012_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 013 voltage 2008_BAT_CELL_013_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 014 voltage 2008_BAT_CELL_014_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 015 voltage 2008_BAT_CELL_015_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 016 voltage 2008_BAT_CELL_016_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 017 voltage 2008_BAT_CELL_017_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 018 voltage 2008_BAT_CELL_018_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 019 voltage 2008_BAT_CELL_019_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 020 voltage 2008_BAT_CELL_020_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 021 voltage 2008_BAT_CELL_021_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 022 voltage 2008_BAT_CELL_022_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 023 voltage 2008_BAT_CELL_023_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 024 voltage 2008_BAT_CELL_024_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 025 voltage 2008_BAT_CELL_025_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 026 voltage 2008_BAT_CELL_026_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 027 voltage 2008_BAT_CELL_027_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 028 voltage 2008_BAT_CELL_028_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 029 voltage 2008_BAT_CELL_029_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 030 voltage 2008_BAT_CELL_030_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 031 voltage 2008_BAT_CELL_031_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 032 voltage 2008_BAT_CELL_032_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 033 voltage 2008_BAT_CELL_033_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 034 voltage 2008_BAT_CELL_034_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 035 voltage 2008_BAT_CELL_035_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 036 voltage 2008_BAT_CELL_036_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 037 voltage 2008_BAT_CELL_037_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 038 voltage 2008_BAT_CELL_038_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 039 voltage 2008_BAT_CELL_039_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 040 voltage 2008_BAT_CELL_040_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 041 voltage 2008_BAT_CELL_041_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 042 voltage 2008_BAT_CELL_042_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 043 voltage 2008_BAT_CELL_043_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 044 voltage 2008_BAT_CELL_044_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 045 voltage 2008_BAT_CELL_045_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 046 voltage 2008_BAT_CELL_046_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 047 voltage 2008_BAT_CELL_047_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 048 voltage 2008_BAT_CELL_048_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 049 voltage 2008_BAT_CELL_049_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 050 voltage 2008_BAT_CELL_050_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 051 voltage 2008_BAT_CELL_051_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 052 voltage 2008_BAT_CELL_052_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 053 voltage 2008_BAT_CELL_053_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 054 voltage 2008_BAT_CELL_054_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 055 voltage 2008_BAT_CELL_055_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 056 voltage 2008_BAT_CELL_056_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 057 voltage 2008_BAT_CELL_057_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 058 voltage 2008_BAT_CELL_058_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 059 voltage 2008_BAT_CELL_059_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 060 voltage 2008_BAT_CELL_060_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 061 voltage 2008_BAT_CELL_061_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 062 voltage 2008_BAT_CELL_062_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 063 voltage 2008_BAT_CELL_063_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 064 voltage 2008_BAT_CELL_064_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 065 voltage 2008_BAT_CELL_065_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 066 voltage 2008_BAT_CELL_066_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 067 voltage 2008_BAT_CELL_067_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 068 voltage 2008_BAT_CELL_068_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 069 voltage 2008_BAT_CELL_069_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 070 voltage 2008_BAT_CELL_070_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 071 voltage 2008_BAT_CELL_071_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 072 voltage 2008_BAT_CELL_072_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 073 voltage 2008_BAT_CELL_073_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 074 voltage 2008_BAT_CELL_074_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 075 voltage 2008_BAT_CELL_075_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 076 voltage 2008_BAT_CELL_076_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 077 voltage 2008_BAT_CELL_077_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 078 voltage 2008_BAT_CELL_078_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 079 voltage 2008_BAT_CELL_079_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 080 voltage 2008_BAT_CELL_080_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 081 voltage 2008_BAT_CELL_081_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 082 voltage 2008_BAT_CELL_082_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 083 voltage 2008_BAT_CELL_083_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 084 voltage 2008_BAT_CELL_084_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 085 voltage 2008_BAT_CELL_085_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 086 voltage 2008_BAT_CELL_086_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 087 voltage 2008_BAT_CELL_087_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 088 voltage 2008_BAT_CELL_088_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 089 voltage 2008_BAT_CELL_089_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 090 voltage 2008_BAT_CELL_090_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 091 voltage 2008_BAT_CELL_091_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 092 voltage 2008_BAT_CELL_092_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 093 voltage 2008_BAT_CELL_093_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 094 voltage 2008_BAT_CELL_094_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,488 to 1,503 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 095 voltage 2008_BAT_CELL_095_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,504 to 1,519 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 096 voltage 2008_BAT_CELL_096_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,520 to 1,535 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 097 voltage 2008_BAT_CELL_097_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,536 to 1,551 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 098 voltage 2008_BAT_CELL_098_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,552 to 1,567 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 099 voltage 2008_BAT_CELL_099_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,568 to 1,583 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 100 voltage 2008_BAT_CELL_100_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,584 to 1,599 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 101 voltage 2008_BAT_CELL_101_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,600 to 1,615 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 102 voltage 2008_BAT_CELL_102_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,616 to 1,631 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 103 voltage 2008_BAT_CELL_103_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,632 to 1,647 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 104 voltage 2008_BAT_CELL_104_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,648 to 1,663 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 105 voltage 2008_BAT_CELL_105_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,664 to 1,679 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 106 voltage 2008_BAT_CELL_106_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,680 to 1,695 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 107 voltage 2008_BAT_CELL_107_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,696 to 1,711 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 108 voltage 2008_BAT_CELL_108_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,712 to 1,727 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 109 voltage 2008_BAT_CELL_109_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,728 to 1,743 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 110 voltage 2008_BAT_CELL_110_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,744 to 1,759 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 111 voltage 2008_BAT_CELL_111_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,760 to 1,775 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 112 voltage 2008_BAT_CELL_112_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,776 to 1,791 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 113 voltage 2008_BAT_CELL_113_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,792 to 1,807 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 114 voltage 2008_BAT_CELL_114_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,808 to 1,823 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 115 voltage 2008_BAT_CELL_115_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,824 to 1,839 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 116 voltage 2008_BAT_CELL_116_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,840 to 1,855 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 117 voltage 2008_BAT_CELL_117_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,856 to 1,871 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 118 voltage 2008_BAT_CELL_118_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,872 to 1,887 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 119 voltage 2008_BAT_CELL_119_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,888 to 1,903 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery cell 120 voltage 2008_BAT_CELL_120_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,904 to 1,919 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Battery current 2008_BAT_CURRENT
- Service 22
DID D497 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2097152 to 2097151 A
- Unit
- A
In testing for 2013 to 2026.
Battery DC current 2008_BAT_DC_CURRENT
- Service 22
DID D816 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -1200 to 67107663 A
- Unit
- A
In testing for 2013 to 2026.
Battery insulation resistance 2008_BAT_INSULATION_RES
- Service 22
DID D47A - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 kΩ
- Unit
- kΩ
In testing for 2013 to 2026.
Battery max unit temperature 2008_BAT_MAX_UNIT_T
- Service 22
DID D817 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2026.
Battery max unit temperature number 2008_BAT_MAX_UNIT_T_NUMBER
- Service 22
DID D445 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2013 to 2026.
Battery min unit temperature 2008_BAT_MIN_UNIT_T
- Service 22
DID D87D - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2026.
Battery min unit temperature number 2008_BAT_MIN_UNIT_T_NUMBER
- Service 22
DID D446 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2013 to 2026.
Battery temperature 2008_BAT_T
- Service 22
DID D8EF - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2013 to 2026.
Cell voltage sum 2008_CELL_V_SUMM
- Service 22
DID D438 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 V
- Unit
- V
In testing for 2013 to 2026.
Centralized voltage maintenance device temperature limiter state 2008_CENTRALIZED_V_T
- Service 22
DID D759 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Computer power supply voltage 2008_COMPUTER_POWER_SUP_V
- Service 22
DID D551 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2013 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2017 to 2018, 2020. Supported for 2015 to 2016, 2021, 2023 to 2024.
Energy accumulator discharge permission state 2008_ENERGY_ACCUMULATOR
- Service 22
DID D74F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Engine control computer supply voltage 2008_ENG_CTRL_COMPUTER_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID D422 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 V
- Unit
- V
In testing for 2013 to 2026.
Engine oil level sensor voltage 2008_ENG_OIL_LEVEL_SENS_V
- Service 22
DID D41E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553 to 6553 mV
- Unit
- mV
In testing for 2013 to 2026.
Evaluation of the total resistance of the voltage maintaining device 2008_EVALUATION_TOT_RES_V
- Service 22
DID D72D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.511
- Unit
- Number
In testing for 2013 to 2026.
High voltage battery charge 2008_HVBAT_SOC_RAW
Pelican can show this parameter as the state of charge.
- Service 22
DID D810 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2026.
High voltage battery charge, calibrated 2008_HVBAT_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID D410 - Module
6B4 → 694 - Every
1 s - Testing for 2013 to 2020, 2023 to 2026
Example reply from a 2022 Peugeot 2008.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x65D9 = 26073 → = 50.923828 %
Confirmed for 2021 to 2022. In testing for 2013 to 2014, 2016, 2019, 2025 to 2026. Not supported for 2015, 2017 to 2018, 2020, 2023 to 2024.
High voltage battery health 2008_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Service 22
DID D860 - Module
6B4 → 694 - Every
3600 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2026.
High voltage battery voltage 2008_HVBAT_VOLT
- Service 22
DID D815 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 V
- Unit
- V
In testing for 2013 to 2026.
High voltage maximum voltage 2008_HVBAT_MAX_VOLT
- Service 22
DID D870 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2013 to 2026.
High voltage minimum voltage 2008_HVBAT_MIN_VOLT
- Service 22
DID D86F - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2013 to 2026.
Highest voltage cell number 2008_HIGHEST_V_CELL
- Service 22
DID D43B - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2013 to 2026.
HV battery energy 2008_HVBAT_KWH
Energy stored in the high voltage battery
- Service 22
DID D865 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 kWh
- Unit
- kWh
In testing for 2013 to 2026.
Lowest voltage cell number 2008_LOWEST_V_CELL_NUMBER
- Service 22
DID D43C - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2013 to 2026.
Maximum power the battery can provide for 10 seconds 2008_MAX_POWER_BAT_CAN_PROVIDE_10
- Service 22
DID D873 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2013 to 2026.
Maximum power the battery can provide for 30 seconds 2008_MAX_POWER_BAT_CAN_PROVIDE_30
- Service 22
DID D874 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2013 to 2026.
Maximum power the battery can withstand for 10 seconds 2008_MAX_POWER_BAT_CAN_10
- Service 22
DID D871 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2013 to 2026.
Maximum power the battery can withstand for 30 seconds 2008_MAX_POWER_BAT_CAN_30
- Service 22
DID D872 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2013 to 2026.
Minimum battery voltage at startup 2008_MIN_BAT_V_STARTUP
- Service 22
DID D4D4 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 V
- Unit
- V
In testing for 2013 to 2026.
On-board charger temperature 2008_ON_BOARD_CHARGER_T
- Service 22
DID D8E1 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2013 to 2026.
Reversible generator voltage 2008_REVERSIBLE_GEN_V
- Service 22
DID D713 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 V
- Unit
- V
In testing for 2013 to 2026.
Service battery charge state 2008_SERVICE_BAT_CHG_ST
- Service 22
DID D742 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Service battery charge status 2008_SERVICE_BAT_CHG_STAT
- Service 22
DID D467 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
In testing for 2013 to 2026.
Service battery temperature 2008_SERVICE_BAT_T
- Service 22
DID D496 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 °C
- Unit
- °C
In testing for 2013 to 2026.
Service battery temperature 2008_SERVICE_BAT_T_6A8
- Service 22
DID D496 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2013 to 2026.
Service battery voltage 2008_SERVICE_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID D78A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 V
- Unit
- V
In testing for 2013 to 2026.
Service battery wear condition 2008_SERVICE_BAT_WEAR
- Service 22
DID D741 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Service cell voltage value 2008_SERVICE_CELL_V
- Service 22
DID D822 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2013 to 2026.
Set voltage of energy storage 2008_SET_V_ENERGY_STORAGE
- Service 22
DID D734 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96 V
- Unit
- V
In testing for 2013 to 2026.
Set voltage of storage battery charging 2008_SET_V_STORAGE_BAT
- Service 22
DID D766 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 V
- Unit
- V
In testing for 2013 to 2026.
Set voltage of the reversible generator 2008_SET_V_REVERSIBLE_GEN
- Service 22
DID D712 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 16.97 V
- Unit
- V
In testing for 2013 to 2026.
Stop permitted by voltage maintainer computer 2008_STOP_PERMITTED_V
- Service 22
DID D749 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Temperature of the electronic power unit of the voltage maintenance device 2008_T_ELECTRONIC_POWER_V
- Service 22
DID D730 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2013 to 2026.
Turbocharger control duty cycle 2008_TURBOCHARGER_CTRL
- Service 22
DID D48A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -128 to 127 %
- Unit
- %
In testing for 2013 to 2026.
Turbocharger first electronic boost 2008_TURBOCHARGER_FIRST
- Service 22
DID D48C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Turbocharger position information 2008_TURBOCHARGER_POS
- Service 22
DID D4EA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2013 to 2026.
Turbocharger pressure measured 2008_TURBOCHARGER_P_MEAS
- Service 22
DID D4D9 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2013 to 2026.
Turbocharger pressure reference 2008_TURBOCHARGER_P
- Service 22
DID D556 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2013 to 2026.
Turbocharger, target position 2008_TURBOCHARGER_TGT_POS
- Service 22
DID D47B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2013 to 2026.
Voltage at the terminals of the energy accumulator 2008_V_TERMINALS_ENERGY
- Service 22
DID D720 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96 V
- Unit
- V
In testing for 2013 to 2026.
Voltage maintainer computer request sent 2008_V_MAINTAINER_COMPUTER_REQ
- Service 22
DID D748 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Voltage maintainer computer restart permission 2008_V_MAINTAINER
- Service 22
DID D747 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Voltage maintainer status 2008_V_MAINTAINER_STAT
- Service 22
DID D72C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2015, 2017 to 2018. Supported for 2020 to 2021, 2023 to 2024.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020. Supported for 2015 to 2018, 2021, 2023 to 2024.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020. Supported for 2015 to 2018, 2021, 2024.
Anti-lock brake or stability control regulating 2008_ABS_EKS_PROCESS_ADJ
- Service 22
DID D474 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Brake circuit pressure 2008_BRAKE_CIRCUIT_P
- Service 22
DID D70E - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -55 to 6498 bar
- Unit
- bar
In testing for 2013 to 2026.
Brake system backup contactor status 2008_BRAKE_SYSTEM_BACKUP
- Service 22
DID D463 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Main brake contactor status 2008_MAIN_BRAKE_CONTACTOR
- Service 22
DID D513 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Secondary brake contactor status 2008_SECONDARY_BRAKE
- Service 22
DID D514 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Vacuum present in the brake system 2008_VACUUM_PRESENT_BRAKE
- Service 22
DID D700 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2015, 2017 to 2018, 2020, 2024. Supported for 2021, 2023.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed
Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.
- Service 01
PID 4E - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2018. Supported for 2023.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 4D - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2018. Supported for 2016, 2021, 2023.
Status
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2023 to 2024.
Engine
5V power supply state number 1 2008_5V_POWER_SUP_ST_1
- Service 22
DID D423 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
5V power supply state number 2 2008_5V_POWER_SUP_ST_2
- Service 22
DID D424 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
5V power supply state number 3 2008_5V_POWER_SUP_ST_3
- Service 22
DID D425 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
5V power supply state number 4 2008_5V_POWER_SUP_ST_4
- Service 22
DID D426 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
12V network allowed stop 2008_12V_NETWORK_ALLOWED
- Service 22
DID D74C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Activation count, brake electromagnetic valve B1 2008_NUM_ACTIVATIONS_B1
- Service 22
DID D745 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Activation count, line pressure control solenoid 2008_NUM_LINE_P_CTRL
- Service 22
DID D751 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Activation count, the electromagnetic valve of brake B2 2008_NUM_ACTIVATIONS_B2
- Service 22
DID D75A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Actual oil pressure 2008_ACT_OIL_P
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 12.75 bar
- Unit
- bar
In testing for 2013 to 2026.
Additional heater control 1 2008_ADDITIONAL_HEATER_1
- Service 22
DID D416 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Air conditioning 2008_AC
- Service 22
DID D4AF - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Air conditioning compressor current 2008_AC_COMP_CURRENT
- Service 22
DID D41C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375
- Unit
- Number
In testing for 2013 to 2026.
Air conditioning high side pressure 2008_AC_HIGH_SIDE_P
- Service 22
DID D8FF - Module
6A2 → 682 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 bar
- Unit
- bar
In testing for 2013 to 2026.
Air conditioning pressure 2008_AC_P
- Service 22
DID D421 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2013 to 2026.
Air doser first electronic loading 2008_AIR_DOSER_FIRST
- Service 22
DID D53B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Air flow 2008_AIR_FLOW
- Service 22
DID D489 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2013 to 2026.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2023.
Air flow target 2008_AIR_FLOW_TGT
- Service 22
DID D48E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2013 to 2026.
Air metering valve duty cycle 2008_AIR_METERING_VLV
- Service 22
DID D461 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2013 to 2026.
Air metering valve position 2008_AIR_METERING_VLV_POS
- Service 22
DID D54F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2013 to 2026.
Air metering valve, target position 2008_AIR_METERING_VLV_TGT
- Service 22
DID D460 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2013 to 2026.
Air temperature by air flow meter 2008_AIR_T_AIR_FLOW_METER
- Service 22
DID D54E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2013 to 2026.
Alternator load value 2008_ALTERNATOR_LOAD
- Service 22
DID D4A5 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2013 to 2026.
Ambient air temperature 2008_AAT_6A9
- Service 22
DID D552 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2013 to 2026.
Ambient temperature 2008_AAT
- Service 22
DID D434 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2013 to 2026.
ANTI START PROGRAMMING STATUS 2008_ANTI_START
- Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Atmospheric pressure 2008_ATMOSPHERIC_P
- Service 22
DID D465 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2013 to 2026.
Automatic restart request from body control module 2008_AUTOMATIC_RESTART_REQ_BSI
- Service 22
DID D70A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Automatic restart request from engine management computer 2008_AUTOMATIC_RESTART
- Service 22
DID D709 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Automatic stop allowed by body control module 2008_AUTOMATIC_STOP
- Service 22
DID D703 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Automatic stop allowed by power steering computer 2008_AUTOMATIC_STOP_ALLOWED_POWER_STEER
- Service 22
DID D705 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Auxiliary heater 2 control 2008_AUXILIARY_HEATER_2
- Service 22
DID D417 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Average mileage for the last 10 regenerations 2008_AVG_MILEAGE_LAST_10
- Service 22
DID D525 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4095 km
- Unit
- km
In testing for 2013 to 2026.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2023 to 2024.
Boost air temperature 2008_BOOST_AIR_T
- Service 22
DID D411 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2013 to 2026.
Button state 2008_BUTTON_ST
- Service 22
DID D517 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2023 to 2024. Supported for 2016.
Camshaft/crankshaft position synchronization 2008_CAM_CRANK_POS
- Service 22
DID D418 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2017 to 2018. Supported for 2015, 2020 to 2021, 2023 to 2024.
CHANGE REPORT IN PROGRESS 2008_CHANGE_REPORT
- Service 22
DID D516 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Combustion engine state 2008_ICE_ST
- Service 22
DID D709 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2015, 2017 to 2018, 2020, 2024. Supported for 2021.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2024.
Commanded oil pressure 2008_CMD_OIL_P
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 bar
- Unit
- bar
In testing for 2013 to 2026.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2018. Supported for 2015, 2021, 2023 to 2024.
Commanded wastegate A position WG_A_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2018.
Commanded wastegate B position WG_B_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2018.
Computer lock 2008_COMPUTER_LOCK
- Service 22
DID DADD - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Computer remote wake-up state 2008_COMPUTER_WAKE_UP_ST
- Service 22
DID D515 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Computer restarts since memory erase 2008_CNT_NUM_RE
- Service 22
DID D4D8 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2026.
Computer temperature 2008_COMPUTER_T
- Service 22
DID D435 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2013 to 2026.
Control current of electromagnetic valve for changing the pressure in the brake system B2 2008_CTRL_CURRENT_P_B2
- Service 22
DID D622 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Control current of the electromagnetic valve for changing the pressure in the brake system B1 2008_CTRL_CURRENT_P_B1
- Service 22
DID D608 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Controlled air supply module 2008_CONTROLLED_AIR_SUP
- Service 22
DID D4A0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Coolant temperature 2008_ECT
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID D8FB - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2013 to 2026.
Coolant temperature 2008_ECT_6A8
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID D415 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2013 to 2026.
Coolant temperature target 2008_ECT_TGT
- Service 22
DID D40D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2013 to 2026.
Coolant temperature, corrected 2008_ECT_CORRECTED
- Service 22
DID D40A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2013 to 2026.
Cruise control, RW status 2008_CRUISE_CTRL_RW_STAT
- Service 22
DID D4B0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Cylinder 1 injector flow correction 2008_CYL_1_INJ_FLOW_CORR
- Service 22
DID D546 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2013 to 2026.
Cylinder 2 injector flow correction 2008_CYL_2_INJ_FLOW_CORR
- Service 22
DID D547 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2013 to 2026.
Cylinder 3 injector flow correction 2008_CYL_3_INJ_FLOW_CORR
- Service 22
DID D548 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2013 to 2026.
Cylinder 4 injector flow correction 2008_CYL_4_INJ_FLOW_CORR
- Service 22
DID D549 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2013 to 2026.
Date 2008_DATE
- Service 22
DID D4CA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 s
- Unit
- s
In testing for 2013 to 2026.
Drive motor coolant inlet temperature 2008_DRIVE_MOTOR_CLT_T
- Service 22
DID D8D6 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2013 to 2026.
Drive motor power 2008_DRIVE_MOTOR_POWER
- Service 22
DID D8D9 - Module
6A2 → 682 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700 W
- Unit
- W
In testing for 2013 to 2026.
Drive motor stator temperature 2008_DRIVE_MOTOR_STATOR_T
- Service 22
DID D8CD - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2013 to 2026.
Drive motor torque, actual 2008_DRIVE_MOTOR_TQ_ACT
- Service 22
DID D8D0 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Drive motor torque, desired 2008_DRIVE_MOTOR_TQ_DES
- Service 22
DID D880 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Driver presence 2008_DRIVER_PRESENCE
- Service 22
DID D723 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Driver, requested torque value 2008_DRIVER_REQ_TQ
- Service 22
DID D507 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Economy mode off state 2008_ECO_MODE_OFF_ST
- Service 22
DID D724 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Electric cooling fan control 2008_GMV_ELEC_COOLING_FAN
- Service 22
DID D42F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Electric machine torque 2008_ELEC_MACHINE_TQ
- Service 22
DID DCB6 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1638 to 4915 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Electric machine torque reduction 2008_ELEC_MACHINE_TQ_REDUCTION
- Service 22
DID DC69 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Energy accumulator state transfer 2008_ENERGY_ACCUMULATOR_ST
- Service 22
DID D755 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Energy accumulator temperature limiter state 2008_ENERGY_ACCUMULATOR_T
- Service 22
DID D758 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Engine control module status 2008_ENG_CTRL_MODULE_STAT
- Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Engine coolant temperature 2008_ECT_6A9
- Service 22
DID D555 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2023 to 2024. Supported for 2016.
Engine oil dilution protection status 2008_ENG_OIL_DILUTION
- Service 22
DID D524 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Engine operating mode 2008_ENG_OP_MODE
- Service 22
DID D553 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 8191 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Engine restart counter 2008_ENG_RESTART_CNT
- Service 22
DID D406 - Module
6A9 → 689 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Engine restart counter by stop and start function 2008_ENG_RESTART_CNT_STOP
- Service 22
DID D71B - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Engine restart request sent by ESP computer 2008_ENG_RESTART_REQ_SENT
- Service 22
DID D70D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2023 to 2024.
Engine stalls 2008_ENG_STALLS
- Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Engine start prohibition control, start lock 2008_ENG_START
- Service 22
DID D703 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Engine stop time 2008_ENG_STOP_TIME
- Service 22
DID D477 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 s
- Unit
- s
In testing for 2013 to 2026.
Engine torque 2008_ENG_TQ
- Service 21
PID C3 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Estimated torque of internal friction of the engine 2008_ESTIMATED_TQ
- Service 22
DID D4E2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Evaluation of carbon content in engine oil 2008_EVALUATION_CARBON
- Service 22
DID D523 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96 %
- Unit
- %
In testing for 2013 to 2026.
Evaluation of the degree of dilution of motor oil 2008_EVALUATION_DEGREE
- Service 22
DID D51F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
In testing for 2013 to 2026.
Exhaust gas recirculation high limit electronic loading 2008_EGR_HIGH_LIM
- Service 22
DID D553 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Exhaust gas recirculation low limit electronic loading 2008_EGR_LOW_LIM
- Service 22
DID D552 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Exhaust gas recirculation valve duty cycle 2008_EGR_VLV_CTRL_SIG_RCO
- Service 22
DID D511 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2013 to 2026.
Exhaust gas recirculation valve first electronic loading 2008_EGR_VLV_FIRST
- Service 22
DID D53A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Exhaust gas recirculation valve position 2008_EGR_VLV_POS
- Service 22
DID D509 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2013 to 2026.
Exhaust gas recirculation valve set position 2008_EGR_VLV_SET_POS
- Service 22
DID D510 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2013 to 2026.
Expected generator supplier identifier of the reversible generator 2008_EXPECTED_GEN
- Service 22
DID D789 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Expected identifier of electronic power circuit of reversible generator generator 2008_EXPECTED_IDENTIFIER_ELECTRONIC
- Service 22
DID D788 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Expected identifier of reversible generator 2008_EXPECTED_IDENTIFIER
- Service 22
DID D787 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2017 to 2018. Supported for 2015, 2020 to 2021, 2023 to 2024.
FUGITIVE TRIP IN EMERGENCY MODE 2008_FUGITIVE_TRIP
- Service 22
DID D671 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Generator mode 2008_GEN_MODE
- Service 22
DID D714 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 19125 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Generator shutdown 2008_GEN_SHUTDOWN
- Service 22
DID D75B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Identifier of the electronic power circuit of the reversible generator 2008_IDENTIFIER
- Service 22
DID D732 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Identifier of the supplier of the reversible generator 2008_IDENTIFIER_SUPPLIER
- Service 22
DID D733 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Immobilizer code programming status 2008_IMMOBILIZER_CODE
- Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Indicated engine torque 2008_INDICATED_ENG_TQ
- Service 22
DID D4D2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Injector code 1 2008_INJ_CODE_1
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 47 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2013 to 2026.
Injector code 2 2008_INJ_CODE_2
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 72 to 111 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2013 to 2026.
Injector code 3 2008_INJ_CODE_3
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 136 to 175 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2013 to 2026.
Injector code 4 2008_INJ_CODE_4
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 200 to 239 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2013 to 2026.
Intake air temperature IATSAE J1979Confirmed
- Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2023 to 2024.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2023 to 2024.
Inverter temperature estimated 2008_INVERTER_T_ESTIMATED
- Service 22
DID DC6A - Module
6A6 → 686 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2013 to 2026.
Inverter temperature, commanded 2008_INVERTER_T_CMD
- Service 22
DID DC04 - Module
6A6 → 686 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2013 to 2026.
Line pressure solenoid valve control current 2008_SLT_LINE_P_VARIATION
- Service 22
DID D606 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Lock status 2008_LOCK_STAT
- Service 22
DID DADD - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2024.
Long-term regeneration capability 2008_LONG_TERM_REGEN
- Service 22
DID D54D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2013 to 2026.
Maximum allowable torque 2008_MAX_ALLOWABLE_TQ
- Service 22
DID D506 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Measured current of electromagnetic valve for changing the pressure in the brake system B2 2008_MEAS_CURRENT_P_B2
- Service 22
DID D623 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Measured current of the electromagnetic valve for changing the pressure in the brake system B1 2008_MEAS_CURRENT_P_B1
- Service 22
DID D609 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Measured line pressure variation solenoid valve current 2008_MEAS_LINE_P
- Service 22
DID D607 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Mileage since last oil change 2008_MILEAGE_SINCE_OIL
- Service 22
DID D43F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2013 to 2026.
Minimum cell capacity 2008_MIN_CELL_CAP
- Service 22
DID D413 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2013 to 2026.
Movement of controlled air supply module 2008_MOVEMENT_CONTROLLED
- Service 22
DID D4EB - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Neutral position sensor status 2008_NEUTRAL_POS_SENS
- Service 22
DID D438 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Number of engine stop information deletion cycles 2008_NUM_ENG_STOP
- Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Oil pressure 2008_OIL_P
- Service 22
DID D429 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2013 to 2026.
Oil pressure reference value 2008_OIL_P_REFERENCE
- Service 22
DID D464 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2013 to 2026.
Oil pressure regulation control 2008_OIL_P_REGULATION
- Service 22
DID D43B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2013 to 2026.
Oil temperature 2008_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID D47D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2013 to 2026.
Outside air temperature 2008_AAT_6A8
- Service 22
DID D414 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2013 to 2026.
Powertrain condition 2008_POWERTRAIN_COND
- Service 22
DID D4BA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Preheating relay control 2008_PREHEATING_RELAY
- Service 22
DID D50C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2013 to 2026.
Presence of the identifier of the reversible generator 2008_PRESENCE_IDENTIFIER
- Service 22
DID D731 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Problems detected while transmitting unlock code 2008_PROBLEMS_DETECTED
- Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Problems detected while transmitting unlock code 2008_PROBLEMS_DETECTED_WHILE
- Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Real engine torque 2008_REAL_ENG_TQ
- Service 22
DID D554 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Regeneration enable 2008_REGEN_ENABLE
- Service 22
DID D528 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Remote wake-up circuit status 2008_REMOTE_WAKE_UP
- Service 22
DID D705 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Remote wake-up state 2008_REMOTE_WAKE_UP_ST
- Service 22
DID D708 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Request to turn on the engine diagnostic indicator 2008_REQ_TURN_ON_ENG
- Service 22
DID D511 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Requested value controlled thermostat 2008_REQ_CONTROLLED
- Service 22
DID D586 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 399 %
- Unit
- %
In testing for 2013 to 2026.
Restart request sent by power steering computer 2008_RESTART_REQ_SENT
- Service 22
DID D70C - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Restart request sent by suspension computer 2008_RESTART_REQ_SENT_SUSPENSION
- Service 22
DID D70E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Return to engine start and restart control by starter 2008_RETURN_ENG_START
- Service 22
DID D764 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Return to starter engine restart control 2008_RETURN_STARTER_ENG
- Service 22
DID D761 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Reverse generator status 2008_REVERSE_GEN_STAT
- Service 22
DID D716 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Reversible generator torque 2008_REVERSIBLE_GEN_TQ
- Service 22
DID D715 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Service network related engine restart request 2008_SERVICE_NETWORK
- Service 22
DID D74B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2024. Supported for 2016.
Short-term regeneration capability 2008_SHORT_TERM_REGEN
- Service 22
DID D54C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2013 to 2026.
Sport mode contactor state 2008_SPORT_MODE_CONTACTOR
- Service 22
DID D503 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Start inhibit control, wired 2008_START_INHIBIT_CTRL
- Service 22
DID D767 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Start or restart inhibition transmitted by engine management computer 2008_START_OR_RESTART
- Service 22
DID D71E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Start prohibition 2008_START_PROHIBITION
- Service 22
DID D51B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Starter activation counter 2008_STARTER_ACTIVATION
- Service 22
DID D71F - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Starter control interface unit operating status 2008_STARTER_CTRL
- Service 22
DID D72A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Starter duty cycle 2008_STARTER_DUTY
- Service 22
DID D478 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 s
- Unit
- s
In testing for 2013 to 2026.
Starter engagement status 2008_STARTER_ENGAGEMENT
- Service 22
DID D4C3 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
State lock/unlock control unit 2008_ST_LOCK_UNLOCK_CTRL
- Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Status of internal ignition motor 2008_STAT_INTERNAL_IGN
- Service 22
DID D412 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Status of the energy accumulator 2008_STAT_ENERGY
- Service 22
DID D722 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2013 to 2026.
Stop allowed by ESP computer 2008_STOP_ALLOWED_ESP
- Service 22
DID D706 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Stop and start function state 2008_STOP_START_FUNCTION
- Service 22
DID D725 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Stop and start switch 2008_STOP_START_SWITCH
- Service 22
DID D726 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Stop permitted by suspension computer 2008_STOP_PERMITTED
- Service 22
DID D707 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Temperature difference between the hottest and the coolest cells 2008_T_DIFF_HOTEST
- Service 22
DID D878 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2013 to 2026.
Temperature of the energy accumulator 2008_T_ENERGY_ACCUMULATOR
- Service 22
DID D721 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2013 to 2026.
The composition of the mixture is calculated by the oxygen sensor 2008_COMPOSITION_MIXTURE
- Service 22
DID D570 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2013 to 2026.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2024.
Torque corresponding to driver requirement 2008_TQ_CORRESPONDING
- Service 22
DID D4E3 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Torque supplied or taken by generator 2008_TQ_SUPPLIED_OR_TAKEN
- Service 22
DID D728 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Total mileage 2008_ODO_6A8
Pelican can show this parameter as the odometer.
- Service 22
DID D49C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2013 to 2026.
Towing device configured 2008_CAN_VEH_BE_EQUIPPED
- Service 22
DID D557 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Traction circuit coolant temperature 2008_TRACTION_CIRCUIT_ECT
- Service 22
DID D8F9 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2013 to 2026.
Traction or stability control regulating 2008_ASR_OR_ESP_SYSTEM
- Service 22
DID D512 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Transmission fluid temperature 2008_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2013 to 2026.
Vacuum circuit vacuum 2008_VACUUM_CIRCUIT
- Service 22
DID D73B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2013 to 2026.
Value during generator load smooth increase 2008_DURING_GEN_LOAD
- Service 22
DID D753 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Vehicle hour meter 2008_VEH_HOUR_METER
- Service 22
DID D801 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 s
- Unit
- s
In testing for 2013 to 2026.
Vehicle mileage since the last oil change under severe vehicle operating conditions 2008_VEH_MILEAGE_SINCE
- Service 22
DID D534 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km
- Unit
- km
In testing for 2013 to 2026.
Wastegate A position WG_A_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2018.
Wastegate B position WG_B_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2018.
Winter mode switch state 2008_WINTER_MODE_SWITCH
- Service 22
DID D502 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Internal
Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017 to 2018.
Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017 to 2018.
Maximum value for air flow rate from mass air flow sensor MAX_MAFSAE J1979Confirmed
- Service 01
PID 50 - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 g/s
- Unit
- g/s
Confirmed for 2018. Supported for 2023.
Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018. Supported for 2023.
Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 kPa
- Unit
- kPa
Confirmed for 2018. Supported for 2023.
Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2018. Supported for 2023.
Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed
- Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2018. Supported for 2023.
Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017 to 2018.
Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed
- Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017 to 2018.
OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2020, 2024.
O2S Output Voltage Bank 1, Sensor 1 O2S11SAE J1979Confirmed
- Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021, 2024.
SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed
- Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2018. Supported for 2015, 2017, 2020 to 2021.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2020, 2024.
Fuel
Amount of fuel additive remaining in the additive tank 2008_AMOUNT_FUEL_ADDITIVE
- Service 22
DID D56C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2013 to 2026.
Calculated fuel injection amount 2008_CALC_FUEL_INJ_AMOUNT
- Service 22
DID D563 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2013 to 2026.
Desired high pressure common rail fuel pressure 2008_DES_HIGH_P_COMMON_P
- Service 22
DID D445 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 bar
- Unit
- bar
In testing for 2013 to 2026.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L/h
- Unit
- L/h
Confirmed for 2023 to 2024.
First fuel additive injection state 2008_FIRST_FUEL_ADDITIVE
- Service 22
DID D56F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Fuel pressure 2008_FUEL_P
- Service 22
DID D41F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2013 to 2026.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2024.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2018. Supported for 2015 to 2017, 2020 to 2021, 2024.
Fuel temperature 2008_FUEL_T
- Service 22
DID D42A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2013 to 2026.
High fuel pressure measured 2008_HIGH_FUEL_P_MEAS
- Service 22
DID D446 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 bar
- Unit
- bar
In testing for 2013 to 2026.
Injection angle of the high-pressure fuel pump 2008_INJ_ANG_HIGH_P_FUEL
- Service 22
DID D588 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2013 to 2026.
Low pressure fuel pump actuator duty cycle 2008_LOW_P_FUEL_PMP
- Service 22
DID D472 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2013 to 2026.
Low pressure fuel pump status 2008_LOW_P_FUEL_PMP_STAT
- Service 22
DID D4ED - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Minimum fuel level 2008_MIN_FLI
- Service 22
DID D56A - Module
6A8 → 688 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Movement
Accelerator pedal position 2008_ACCEL_PEDAL_POS
- Service 22
DID D407 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2013 to 2026.
Accelerator pedal position 2008_ACCEL_PEDAL_POS_6A9
- Service 21
PID C3 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.45 %
- Unit
- %
In testing for 2013 to 2026.
Accelerator pedal position 2008_ACCEL_PEDAL_POS_6A9_6A9
- Service 22
DID D505 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2013 to 2026.
Accelerator pedal position 2008_ACCEL_PEDAL_POS_6B4
- Service 22
DID D407 - Module
6B4 → 694 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2013 to 2026.
Accelerator pedal position, recalculated 2008_ACCEL_PEDAL_POS_RECALCULATED
- Service 22
DID D407 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 %
- Unit
- %
In testing for 2013 to 2026.
Accelerator pedal position, track 1 2008_ACCEL_PEDAL_POS_1
- Service 22
DID D491 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 399 %
- Unit
- %
In testing for 2013 to 2026.
Accelerator pedal position, track 2 2008_ACCEL_PEDAL_POS_2
- Service 22
DID D492 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 399 %
- Unit
- %
In testing for 2013 to 2026.
Clutch release state at stop, creep speed reduction 2008_CLU_RELEASE_ST_STOP
- Service 22
DID D672 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Crankshaft speed 2008_CRANK_SPD
- Service 22
DID D462 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Crankshaft speed determined by camshaft sensor 2008_CRANK_SPD_DETERMINED
- Service 22
DID D499 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Cruise control set speed 2008_CRUISE_CTRL_SET_SPD
- Service 22
DID D475 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2013 to 2026.
Engine RPM 2008_RPM
Pelican can show this parameter as the engine speed.
- Service 22
DID D400 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Engine RPM 2008_RPM_6A9
Pelican can show this parameter as the engine speed.
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Input shaft speed 2008_INPUT_SHFT_SPD
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Motor speed 2008_MOTOR_SPD
- Service 22
DID DC00 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Set speed of electric cooling fan 2008_SET_SPD_ELEC_COOLING
- Service 22
DID D4AA - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2013 to 2026.
STATUS COMMANDS REGULATION OR LIMITATION SPEED 2008_STAT_COMMANDS
- Service 22
DID D704 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Torque converter slip speed, measured 2008_TQ_CONV_SLIP_SPD
- Service 22
DID D654 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -8128 to 8192 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Vehicle speed 2008_VSS
Pelican can show this parameter as the speed.
- Service 22
DID D402 - Module
6A2 → 682 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
In testing for 2013 to 2026.
Vehicle speed 2008_VSS_6A8
Pelican can show this parameter as the speed.
- Service 22
DID D402 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 km/h
- Unit
- km/h
In testing for 2013 to 2026.
Vehicle speed 2008_VSS_6A9
Pelican can show this parameter as the speed.
- Service 21
PID C8 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2013 to 2026.
Vehicle speed 2008_VSS_6A9_6A9
Pelican can show this parameter as the speed.
- Service 22
DID D711 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2013 to 2026.
Vehicle speed 2008_VSS_6B4
Pelican can show this parameter as the speed.
- Service 22
DID D802 - Module
6B4 → 694 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4194368 km/h
- Unit
- km/h
In testing for 2013 to 2026.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2024. Supported for 2016, 2023.
Vehicle speed limiter set speed 2008_VSS_LIMITER_SET_SPD
- Service 22
DID D476 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2013 to 2026.
Vehicle speed limiter status, LW 2008_VSS_LIMITER_STAT_LW
- Service 22
DID D4C0 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Vehicle speed, ESP 2008_VSS_ESP
Pelican can show this parameter as the speed.
- Service 22
DID D802 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 km/h
- Unit
- km/h
In testing for 2013 to 2026.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2017 to 2018. Supported for 2015 to 2016, 2020 to 2021, 2023 to 2024.
Tires
Average front wheel speed 2008_AVG_FRONT_WHL_SPD
- Service 22
DID D530 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2621 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Average speed front wheels 2008_AVG_SPD_FRONT_WHEELS
- Service 22
DID D533 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2013 to 2026.
Counter of occurrence of enhanced resonance of the twin flywheel of the engine 2008_CNT_OCCURRENCE
- Service 22
DID D4E4 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2026.
Counter of occurrence of resonance of the twin flywheel of the engine 2008_CNT_OCCURRENCE_RESONANCE
- Service 22
DID D4E5 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2026.
Rear left wheel speed 2008_RL_WHL_SPD
- Service 22
DID D531 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2013 to 2026.
Rear right wheel speed 2008_RR_WHL_SPD
- Service 22
DID D532 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2013 to 2026.
Transmission
Activation count, additional oil pump, ATN8 gearbox 2008_NUM_ADDITIONAL_OIL
- Service 22
DID D750 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Activation count, clutch electromagnetic valve C2 2008_NUM_ACTIVATIONS_CLU_ELECTROMAGNETIC_VLV_C2
- Service 22
DID D743 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Activation count, clutch electromagnetic valve C3 2008_NUM_ACTIVATIONS_CLU_C3
- Service 22
DID D744 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Activation count, clutch protection C1 2008_NUM_ACTIVATIONS_CLU_C1
- Service 22
DID D731 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Activation count, clutch protection C2 2008_NUM_ACTIVATIONS_CLU_C2
- Service 22
DID D731 - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Activation count, gear 7 2008_NUM_ACTIVATIONS_GEAR_7
- Service 22
DID D75B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Activation count, shift solenoid SC2 2008_NUM_SHIFT_SOLENOID
- Service 22
DID D752 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Activation count, shift solenoid SC3 2008_NUM_SHIFT_SOLENOID_ACTIVATIONS_SC3
- Service 22
DID D753 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Activation count, the electromagnetic valve for controlling the automatic transmission locking finger in position p 2008_NUM_ACTIVATIONS_P
- Service 22
DID D758 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Activation count, the electromagnetic valve of clutch C4 2008_NUM_ACTIVATIONS_C4
- Service 22
DID D759 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Activation count, the electromagnetic valve of the clutch C1 2008_NUM_ACTIVATIONS_C1
- Service 22
DID D742 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Activation count, torque converter lockup electromagnetic valve 2008_NUM_ACTIVATIONS_TQ
- Service 22
DID D746 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Activation of additional oil pump, ATN8 gearbox 2008_ACTIVATION
- Service 22
DID D616 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2013 to 2026.
Additional oil pump control status, atn8 transmission 2008_ADDITIONAL_OIL_PMP
- Service 22
DID D617 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Automatic restart request from transmission computer 2008_AUTOMATIC_RESTART_REQ
- Service 22
DID D70B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Automatic stop allowed by gearbox computer 2008_AUTOMATIC_STOP_ALLOWED
- Service 22
DID D704 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Automatic transmission fluid temperature 2008_AUTOMATIC_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID D550 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2026.
Automatic transmission in emergency mode 2008_AUTOMATIC_TRANS_EMERGENCY
- Service 22
DID D670 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Automatic transmission in park position 2008_AUTOMATIC_TRANS_PARK
- Service 22
DID D70B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Automatic transmission input shaft mode, calculated 2008_AUTOMATIC_TRANS_INPUT_SHFT_MODE
- Service 22
DID D651 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Automatic transmission input shaft mode, measured 2008_AUTOMATIC_TRANS_INPUT_SHFT
- Service 22
DID D650 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Automatic transmission lubrication solenoid control current 2008_AUTOMATIC_TRANS_LUBRICATION
- Service 22
DID D61A - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Automatic transmission oil aging sensor 2008_AUTOMATIC_TRANS_OIL
- Service 22
DID D405 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Automatic transmission oil drain 2008_DRAIN_TRANS
- Service 22
DID D509 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Automatic transmission output shaft mode, calculated 2008_AUTOMATIC_TRANS_OUTPUT_SHFT_MODE
- Service 22
DID D653 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -8128 to 4186112 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Automatic transmission output shaft mode, measured 2008_AUTOMATIC_TRANS_OUTPUT
- Service 22
DID D652 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Automatic transmission overheat indicator request 2008_AUTOMATIC_TRANS
- Service 22
DID D510 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Automatic transmission torque request 2008_AUTOMATIC_TRANS_TQ
- Service 22
DID D508 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2013 to 2026.
Calculated gear in gearbox 2008_CALC_GEAR_GEARBOX
- Service 22
DID D409 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Clutch pedal 2008_CLU_PEDAL
- Service 22
DID D404 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Clutch pedal position value 2008_CLU_PEDAL_POS
- Service 22
DID D469 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2013 to 2026.
Control current of electromagnetic valve for regulating the pressure in the control system of the oil pressure accumulator, AMN8 gearbox 2008_CTRL_CURRENT_P_P
- Service 22
DID D625 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Control current of electromagnetic valve of actuator of automatic transmission lock-up in position p 2008_CTRL_CURRENT_ELECTROMAGNETIC_VLV_P
- Service 22
DID D61E - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Control current of electromagnetic valve of change of pressure of torque converter lock-up 2008_CTRL_CURRENT_P
- Service 22
DID D61C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Control current of the electromagnetic valve for changing the gear shift SC2 2008_CTRL_CURRENT
- Service 22
DID D60A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Control current of the electromagnetic valve of change of pressure of clutch C3 2008_CTRL_CURRENT_P_C3
- Service 22
DID D614 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Control current of the electromagnetic valve of change of pressure of clutch C4 2008_CTRL_CURRENT_P_C4
- Service 22
DID D620 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Control current of the solenoid valve for changing the pressure of the clutch C1 2008_CTRL_CURRENT_P_C1
- Service 22
DID D610 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Control current of the solenoid valve for changing the pressure of the clutch C2 2008_CTRL_CURRENT_P_C2
- Service 22
DID D612 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
DC-DC converter temperature 2008_DC_DC_CONV_T
- Service 22
DID D8CE - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2013 to 2026.
Engaged gear 2008_ENGAGED_GEAR
- Service 22
DID D43D - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Engaged gear 2008_ENGAGED_GEAR_6A9
- Service 22
DID D501 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Exhaust gas temperature after upstream catalytic converter 2008_EXH_GAS_T_AFTER_PRE
- Service 22
DID D555 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2013 to 2026.
Exhaust gas temperature before upstream catalytic converter 2008_EXH_GAS_T_BEFORE_PRE
- Service 22
DID D52E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2013 to 2026.
Gear in the process of engaging 2008_GEAR_PROCESS
- Service 22
DID D43E - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Gear shift knob under steering wheel 2008_GEAR_SHIFT_KNOB
- Service 22
DID D520 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Gear shift lever position displayed on instrument panel 2008_GEAR_SHIFT_LEVER_POS_ON
- Service 22
DID D500 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Maximum clutch travel during gear shift 2008_MAX_CLU_TRAVEL
- Service 22
DID D498 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
In testing for 2013 to 2026.
Measured current of control of electromagnetic valve of automatic transmission lubrication 2008_MEAS_CURRENT_CTRL
- Service 22
DID D61B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Measured current of control of electromagnetic valve of change of pressure of torque converter lock-up 2008_MEAS_CURRENT_CTRL_P
- Service 22
DID D61D - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Measured current of the electromagnetic valve for changing the gear shift SC2 2008_MEAS_CURRENT
- Service 22
DID D60B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Measured current of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 2008_MEAS_CURRENT_P_P
- Service 22
DID D626 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Measured current of the electromagnetic valve of change of pressure of clutch C3 2008_MEAS_CURRENT_P_C3
- Service 22
DID D615 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Measured current of the electromagnetic valve of change of pressure of clutch C4 2008_MEAS_CURRENT_P_C4
- Service 22
DID D621 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Measured current of the solenoid valve for changing the pressure of the clutch C1 2008_MEAS_CURRENT_P_C1
- Service 22
DID D611 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Measured current of the solenoid valve for changing the pressure of the clutch C2 2008_MEAS_CURRENT_P_C2
- Service 22
DID D613 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Measured current of the solenoid valve for controlling the locking finger of the automatic transmission in position p 2008_MEAS_CURRENT_P
- Service 22
DID D61F - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Nitrogen oxide content after catalytic converter, ppm 2008_NOX_CONTENT_AFTER
- Service 22
DID D53D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2013 to 2026.
Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 2008_NOX_CONTENT_MEAS
- Service 22
DID D545 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2013 to 2026.
Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 2008_NOX_CONTENT_MEAS_INLET_NOX
- Service 22
DID D576 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2013 to 2026.
Number of engagements of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 2008_NUM_ENGAGEMENTS_P_P
- Service 22
DID D75D - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of gear engagements 1 2008_NUM_GEAR_ENGAGEMENTS_1
- Service 22
DID D747 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of gear engagements 2 2008_NUM_GEAR_ENGAGEMENTS_2
- Service 22
DID D748 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of gear engagements 3 2008_NUM_GEAR_ENGAGEMENTS_3
- Service 22
DID D749 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of gear engagements 4 2008_NUM_GEAR_ENGAGEMENTS_4
- Service 22
DID D74A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of gear engagements 5 2008_NUM_GEAR_ENGAGEMENTS_5
- Service 22
DID D74B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of gear engagements 6 2008_NUM_GEAR_ENGAGEMENTS_6
- Service 22
DID D74C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of gear engagements 8 2008_NUM_GEAR_ENGAGEMENTS_8
- Service 22
DID D75C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of gear engagements n 2008_NUM_GEAR_ENGAGEMENTS_N
- Service 22
DID D74E - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of gear engagements right 2008_NUM_GEAR_ENGAGEMENTS
- Service 22
DID D74D - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of shift solenoid operated automatic transmission lubrication control valve 2008_NUM_SHIFT_SOLENOID_OPERATED
- Service 22
DID D756 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of shift solenoid operated SC4 2008_NUM_SHIFT_SOLENOID_OPERATED_SC4
- Service 22
DID D754 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of shift solenoid operated SC5 2008_NUM_SHIFT_SOLENOID_OPERATED_SC5
- Service 22
DID D755 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Number of shift solenoid operated torque converter lock-up pressure regulating valve 2008_NUM_SHIFT_SOLENOID_P
- Service 22
DID D757 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2013 to 2026.
Operating mode used by the automatic transmission 2008_OP_MODE_USED
- Service 22
DID D673 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Position of the gearshift lever 2008_POS_GEARSHIFT_LEVER
- Service 22
DID D700 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Proportional clutch pedal sensor 2008_PROPORTIONAL_CLU
- Service 22
DID D56E - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Reverse gear contactor status 2008_REVERSE_GEAR
- Service 22
DID D43C - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
SC5 shift solenoid control current 2008_SC5_SHIFT_SOLENOID
- Service 22
DID D618 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
SC5 shift solenoid measured current 2008_SC5_SHIFT_SOLENOID_MEAS
- Service 22
DID D619 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Shift solenoid control current SC3 2008_SHIFT_SOLENOID_CTRL
- Service 22
DID D60C - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Shift solenoid control current SC4 2008_SHIFT_SOLENOID_CTRL_CURRENT_SC4
- Service 22
DID D60E - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Shift solenoid measured current SC3 2008_SHIFT_SOLENOID_MEAS
- Service 22
DID D60D - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Shift solenoid measured current SC4 2008_SHIFT_SOLENOID_MEAS_CURRENT_SC4
- Service 22
DID D60F - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Shift-lock control 2008_SHIFT_LOCK_CTRL
- Service 22
DID D701 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Start permission from gearbox computer 2008_START_PERMISSION
- Service 22
DID D41A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Torque converter lock-up pressure variation solenoid valve control current 2008_TQ_CONV_LOCK_UP_P
- Service 22
DID D604 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Torque converter lock-up pressure variation solenoid valve control current 2008_TQ_CONV_LOCK_UP_P_VARIATION
- Service 22
DID D605 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2013 to 2026.
Torque converter slip mode, theoretical value 2008_TQ_CONV_SLIP_MODE
- Service 22
DID D655 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -8128 to 8192 rpm
- Unit
- rpm
In testing for 2013 to 2026.
Torque converter status 2008_TQ_CONV_STAT
- Service 22
DID D504 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2026.
Upstream catalytic converter aging 2008_PRE_CATALYTIC_CONV
- Service 22
DID D559 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2013 to 2026.
Trips
Distance to next oil change 2008_DIST_NEXT_OIL_CHANGE
- Service 22
DID D536 - Module
6A8 → 688 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2013 to 2026.
Distance traveled since the last regeneration 2008_DIST_TRAVELED_SINCE
- Service 22
DID D519 - Module
6A8 → 688 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4095 km
- Unit
- km
In testing for 2013 to 2026.
Odometer 2008_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID D49C - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2013 to 2026.
Odometer 2008_ODO_6A2
Pelican can show this parameter as the odometer.
- Service 22
DID D49C - Module
6A2 → 682 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2013 to 2026.
Odometer 2008_ODO_6A6
Pelican can show this parameter as the odometer.
- Service 22
DID D49C - Module
6A6 → 686 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 km
- Unit
- km
In testing for 2013 to 2026.
Odometer 2008_ODO_6A9
Pelican can show this parameter as the odometer.
- Service 22
DID D802 - Module
6A9 → 689 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2013 to 2026.