Nissan Titan XD

Parameters

The Nissan Titan XD has 14 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Accelerator pedal position TITANXD_APP

  • Service 22DID 1115
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2016 to 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Control

Accelerator pedal position TITANXD_APP

  • Service 22DID 1115
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2016 to 2024.

Brake master cylinder pressure TITANXD_BRAKE_MC_P

  • Service 22DID 1209
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.536
Range
0 to 42666.015
Unit
Raw value

In testing for 2016 to 2024.

Engine

Air conditioning compressor TITANXD_AC_COMP

  • Service 22DID 1307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2024.

Air/fuel ratio adjustment, bank 2 TITANXD_F_RAT_ADJ_B2

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 %
Unit
%

In testing for 2016 to 2024.

Camshaft advance angle, bank 2 TITANXD_CAM_ADV_ANG_B2

  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2016 to 2024.

Camshaft valve duty, bank 2 TITANXD_CAM_VLV_DUTY_B2

  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2016 to 2024.

Cooling fan high TITANXD_COOLING_FAN_HIGH

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2024.

Cooling fan low TITANXD_COOLING_FAN_LOW

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2024.

Idle control mode TITANXD_IDLE_CTRL_MODE

  • Service 22DID 1307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2024.

Mass air flow sensor voltage, bank 2 TITANXD_MAF_V_B2

  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2016 to 2024.

Tires

Wheel 1 pressure TITANXD_WHL_1_P

  • Service 21PID 10
  • Module758 → 778
  • Every15 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 psi
Unit
psi

In testing for 2016 to 2024.

Wheel 2 pressure TITANXD_WHL_2_P

  • Service 21PID 10
  • Module758 → 778
  • Every15 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 psi
Unit
psi

In testing for 2016 to 2024.

Wheel 3 pressure TITANXD_WHL_3_P

  • Service 21PID 10
  • Module758 → 778
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 psi
Unit
psi

In testing for 2016 to 2024.

Wheel 4 pressure TITANXD_WHL_4_P

  • Service 21PID 10
  • Module758 → 778
  • Every15 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 psi
Unit
psi

In testing for 2016 to 2024.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.