Nissan Rogue Select

Parameters

The Nissan Rogue Select has 317 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine speed ROGUE_TCM_RPMConfirmed

Pelican can show this parameter as the engine speed.

  • Service 22DID 1204
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0299 = 665 → 665 rpm

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Accelerator pedal position sensor 1, volts ROGUE_ACCEL_PEDAL_POS_SENS_1

  • Service 22DID 120D
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Accelerator pedal position sensor 2, volts ROGUE_ACCEL_PEDAL_POS_SENS_2

  • Service 22DID 120E
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

ALTERNATOR set point VOLTAGE ROGUE_ALTERNATOR_SETPOINT_V

  • Service 21PID 69
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2010, 2018 to 2019, 2022 to 2023, 2025 to 2026. Supported for 2014 to 2017, 2020 to 2021, 2024.

EVAP pressure sensor voltage ROGUE_EVAP_P_SENS_V

  • Service 22DID 1115
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Exhaust gas recirculation temperature sensor voltage ROGUE_EGR_T_SENS_V

  • Service 22DID 1105
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Fuel pressure sensor voltage ROGUE_FUEL_P_SENS_V

  • Service 22DID 120C
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×413107
Range
0 to 20 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Fuel rail temperature sensor voltage ROGUE_FUEL_RAIL_T_SENS_V

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Fuel tank temperature sensor voltage ROGUE_FUEL_TANK_T_SENS_V

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Manifold pressure sensor voltage ROGUE_MANIFOLD_P_SENS_V

  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Mass air flow volts ROGUE_MAF_VOLTS

  • Service 22DID 1204
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2008 to 2026.

Refrigerant fluid sensor voltage ROGUE_REFRIGERANT_FLUID_V

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Roll-over sensor voltage ROGUE_ROLL_OVER_SENS_V

  • Service 22DID 121F
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Throttle position sensor 1, volts ROGUE_THROTTLE_POS_SENS_1

  • Service 22DID 120F
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Throttle position sensor 2, volts ROGUE_THROTTLE_POS_SENS_2

  • Service 22DID 1210
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Upstream oxygen sensor voltage ROGUE_UP_OXYGEN_SENS_V

  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Climate

A/C status ROGUE_AC_STATUSConfirmed

  • Service 22DID 4007
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2020, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Off or on

Confirmed for 2021 to 2024, 2026. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014 to 2016, 2018 to 2020.

Air conditioning compressor speed ROGUE_AC_COMP_RPM

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Air conditioning on ROGUE_HVAC_AC_ON

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 80 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018. Supported for 2019, 2021 to 2026.

Ambient air temperature ROGUE_AATConfirmed

  • Service 22DID 4008
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2020, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021 to 2024, 2026. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014 to 2016, 2018 to 2020.

Ambient air temperature, climate module ROGUE_HVAC_AAT

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Blower on ROGUE_HVAC_FAN_ON

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Blower voltage ROGUE_HVAC_BLOWER_V

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 89 to 95 of the reply, 7 bits.

Formula
val
Range
0 to 127 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Cabin temperature ROGUE_HVAC_CABIN_T

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Engine coolant temperature ROGUE_ECTConfirmed

  • Service 22DID F467
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2020, 2025

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021 to 2024, 2026. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014 to 2016, 2018 to 2020.

Evaporator temperature ROGUE_HVAC_EVAP_T

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Sun load ROGUE_HVAC_SUNLOAD

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2010, 2016, 2018 to 2019, 2025. Supported for 2014 to 2015, 2017, 2020 to 2024, 2026.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2010, 2018 to 2020, 2026. Supported for 2014 to 2017, 2021 to 2025.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2010, 2018 to 2019. Supported for 2014, 2021 to 2026.

Accelerator pedal position ROGUE_APPConfirmed

  • Service 22DID 1115
  • Module740 → 760
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Anti-lock brake steering angle ROGUE_ABS_STEER_ANGConfirmed

  • Service 22DID 1208
  • Module740 → 760
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

0xFFD0 = -48 → -4810 = -4.8 °

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Brake master cylinder pressure count ROGUE_BRAKE_MC_PConfirmed

  • Service 22DID 1209
  • Module740 → 760
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

0xFFFE = -2 → -2

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

BRAKE SWITCH, number 1 ROGUE_BRAKE_SWITCH_NUMBER_1

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

BRAKE SWITCH, number 2 ROGUE_BRAKE_SWITCH_NUMBER_2

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Left turn signal ROGUE_TURN_SIGNAL_LEFTConfirmed

  • Service 22DID 0103
  • Module707 → 727
  • Every1 s
  • Testing for 2008 to 2017, 2021 to 2026

Example reply from a 2020 Nissan Rogue Select.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014 to 2016, 2021 to 2024, 2026.

Parking brake ROGUE_PARKING_BRAKE

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Relative throttle position TP_RSAE J1979Confirmed

Relative or 'learned' throttle position.

  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2010, 2018 to 2019. Supported for 2014 to 2017, 2021 to 2026.

Right turn signal ROGUE_TURN_SIGNAL_RIGHTConfirmed

  • Service 22DID 0103
  • Module707 → 727
  • Every1 s
  • Testing for 2008 to 2017, 2021 to 2026

Example reply from a 2020 Nissan Rogue Select.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014 to 2016, 2021 to 2024, 2026.

Steering wheel angle ROGUE_STEER_ANGLEConfirmed

Negative values are clockwise, positive values are counter-clockwise.

  • Service 22DID 0110
  • Module723 → 735
  • Every250 ms
  • Testing for 2008 to 2017, 2021 to 2026

Example reply from a 2020 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

0x0000 = 0 → 010 = 0 °

Confirmed for 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014 to 2016, 2021 to 2024, 2026.

Wired brake contact ROGUE_WIRED_BRAKE_CONTACT

  • Service 22DID 2026
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Yaw rate ROGUE_YAW_RATEConfirmed

  • Service 22DID 0101
  • Module723 → 735
  • Every250 ms
  • Testing for 2008 to 2017, 2021 to 2026

Example reply from a 2020 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

0x0000 = 0 → 010 = 0 °

Confirmed for 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014 to 2016, 2021 to 2024, 2026.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2010, 2018 to 2019. Supported for 2014, 2021 to 2026.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2010, 2018 to 2019. Supported for 2014, 2021 to 2026.

Cruise control

Cruise control set speed ROGUE_CC_SConfirmed

  • Service 22DID 122B
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2008 to 2009, 2011 to 2017, 2019, 2021 to 2026

Example reply from a 2020 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 3686 km/h
Unit
km/h

0x0000 = 0 → 0×9160 = 0 km/h

Confirmed for 2010, 2018, 2020. In testing for 2008 to 2009, 2011 to 2017, 2019, 2021 to 2026.

Radar distance ROGUE_RADAR_DISTANCEConfirmed

  • Service 22DID 0107
  • Module723 → 735
  • Every250 ms
  • Testing for 2008 to 2017, 2021 to 2026

Example reply from a 2020 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 m
Unit
m

0x0000 = 0 → 010 = 0 m

Confirmed for 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014 to 2016, 2021 to 2024, 2026.

Relative speed ROGUE_RADAR_SPEEDConfirmed

  • Service 22DID 0108
  • Module723 → 735
  • Every250 ms
  • Testing for 2008 to 2017, 2021 to 2026

Example reply from a 2020 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 m/s
Unit
m/s

0x0000 = 0 → 010 = 0 m/s

Confirmed for 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014 to 2016, 2021 to 2024, 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2010, 2014 to 2015, 2018 to 2023, 2025 to 2026. Supported for 2016 to 2017, 2024.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed

Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.

  • Service 01PID 4E
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2010.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 4D
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2021 to 2025.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018 to 2019, 2026. Supported for 2014 to 2017, 2020 to 2025.

Engine

A/F ratio adj ROGUE_F_RAT_ADJConfirmed

  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2017, 2021 to 2026

Example reply from a 2020 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 %
Unit
%

0x5C = 92 → 92−100 = -8 %

Confirmed for 2018 to 2020. In testing for 2008 to 2017, 2021 to 2026.

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2010, 2018 to 2020, 2026. Supported for 2014 to 2017, 2021 to 2025.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2020, 2026. Supported for 2024.

Air conditioning compressor ROGUE_AC_COMPConfirmed

  • Service 22DID 1307
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2010, 2018 to 2020, 2022 to 2023, 2026. Supported for 2014 to 2017, 2021, 2024 to 2025.

Auto emergency braking system request ROGUE_AUTO_EMERGENCY

  • Service 22DID 2170
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2010, 2018 to 2020, 2026. Supported for 2014 to 2017, 2021 to 2025.

Base injection timing ROGUE_BASE_INJ_TIM

  • Service 22DID 1207
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2048
Range
0 to 31.99 ms
Unit
ms

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Braking detected multiplex signal ROGUE_BRAKING_DETECTED

  • Service 22DID 200F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Butane percentage ROGUE_BUTANE_PERCENTAGE

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val×781320000
Range
0 to 99.61 %
Unit
%

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2010, 2018 to 2020, 2022 to 2023, 2026. Supported for 2014 to 2017, 2021, 2024 to 2025.

Camshaft adv angle ROGUE_CAM_ADV_ANGConfirmed

  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

0x80 = 128 → 1282−64 = 0 °

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Camshaft valve duty ROGUE_CAM_VLV_DUTYConfirmed

  • Service 22DID 1138
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

0x00 = 0 → 0×2564 = 0 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2010, 2018 to 2020, 2026. Supported for 2014 to 2017, 2021 to 2025.

Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed

  • Service 01PID 3D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2020.

Cold starting programming ROGUE_COLD_STARTING

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026. Supported for 2021 to 2025.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2010, 2014 to 2015, 2018 to 2020, 2022 to 2023, 2026. Supported for 2016 to 2017, 2021, 2024 to 2025.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2010, 2018 to 2020, 2026. Supported for 2014 to 2017, 2021 to 2025.

Commanded Throttle Actuator A Control TAC_A_CMDSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026.

Commanded Throttle Actuator B Control TAC_B_CMDSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2010, 2018 to 2020, 2026. Supported for 2021 to 2025.

Coolant temperature ROGUE_ECT_7E0

  • Service 22DID 1406
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Cooling fan high ROGUE_COOLING_FAN_HIGHConfirmed

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Cooling fan low ROGUE_COOLING_FAN_LOWConfirmed

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Cruise control ROGUE_CRUISE_CTRL

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Duration of - button press ROGUE_DUR_BUTTON_PRESS_7E0

  • Service 22DID 207C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 s
Unit
s

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Duration of + button press ROGUE_DUR_BUTTON_PRESS

  • Service 22DID 207B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 s
Unit
s

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Duration of resume button press ROGUE_DUR_RESUME_BUTTON

  • Service 22DID 207A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 s
Unit
s

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Duration of suspend button press ROGUE_DUR_SUSPEND_BUTTON

  • Service 22DID 207D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 s
Unit
s

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

EGR error EGR_ERRSAE J1979Confirmed

  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2026. Supported for 2021 to 2025.

Electric fuel pump learning value ROGUE_EFP_LEARNING

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val65535−0.5
Range
-0.5 to 0.5 %
Unit
%

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2010, 2014 to 2015, 2018 to 2020, 2022 to 2023, 2026. Supported for 2016 to 2017, 2021, 2024 to 2025.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2020, 2026.

Engine oil temperature EOTSAE J1979Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 01PID 5C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2023, 2026. Supported for 2024 to 2025.

Engine oil temperature ROGUE_EOT

  • Service 22DID 111F
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2020, 2026.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2010, 2018 to 2020, 2026. Supported for 2014 to 2017, 2021 to 2025.

Engine torque ROGUE_ENG_TQ

  • Service 22DID 2004
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−400
Range
-400 to 32367 N·m
Unit
N·m

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

EVAP purge duty ROGUE_EVAP_PURGE_DUTYConfirmed

  • Service 22DID 1110
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Evap system vapor pressure EVAP_VPSAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Service 01PID 32
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4000
Range
-8192 to 8191.75 kPa
Unit
kPa

Confirmed for 2010, 2018 to 2020, 2026. Supported for 2014 to 2017, 2021 to 2025.

Idle control mode ROGUE_IDLE_CTRL_MODEConfirmed

  • Service 22DID 1307
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Ignition advance ROGUE_IGN_ADVANCE

  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×-1+112
Range
-143 to 112
Unit
Number

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Ignition timing advance ROGUE_IGN_TIM_ADVANCEConfirmed

  • Service 22DID 110A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×-1+110
Range
-145 to 110 °
Unit
°

0x64 = 100 → 100×-1+110 = 10 °

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Ih_defactrposition ROGUE_IH_DEFACTRPOSITIONConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x7F = 127 → 127 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Ih_feetventactrposition ROGUE_IHConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x27 = 39 → 39 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Ih_leftmixactrposition ROGUE_IH_LEFTMIXACTRPOSITIONConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x44 = 68 → 68 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Ih_rearmixactrposition ROGUE_IH_REARMIXACTRPOSITIONConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Ih_recyactrposition ROGUE_IH_RECYACTRPOSITIONConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x64 = 100 → 100 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Ih_reserveactrposition ROGUE_IH_RESERVEACTRPOSITIONConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x7F = 127 → 127 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Ih_rightmixactrposition ROGUE_IH_RIGHTMIXACTRPOSITIONConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x42 = 66 → 66 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2010, 2018 to 2020. Supported for 2014 to 2017, 2021 to 2022.

Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026.

Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026.

Intake camshaft advance, bank 2 ROGUE_CAM_ADV_B2

  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2018 to 2019, 2026. Supported for 2020 to 2025.

Intake valve timing solenoid duty, bank 2 ROGUE_CAM_DUTY_B2

  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2010, 2018 to 2020, 2026. Supported for 2014 to 2017, 2021 to 2025.

Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed

  • Service 01PID 09
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2020.

Low-pressure fuel pump drive duty ROGUE_LPLI_PMP_PWM_SIG

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val×0.0015259
Range
0 to 99.99 %
Unit
%

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Manifold pressure ROGUE_MANIFOLD_P

  • Service 22DID 140E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000
Range
0 to 255000
Unit
Raw value

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Manual or assisted parking brake ROGUE_MANUAL_OR_ASSISTED

  • Service 22DID 222B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Mass air flow ROGUE_MAFConfirmed

  • Service 22DID 1209
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 g/s
Unit
g/s

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Mass air flow sensor voltage, bank 2 ROGUE_MAF_V_B2

  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Number of abnormal cc/sl transitions ROGUE_NUM_ABNORMAL_CC_SL

  • Service 22DID 207E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Oh_defactrreq ROGUE_OH_DEFACTRREQConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Oh_feetventactrreq ROGUE_OH_FEETVENTACTRREQConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x27 = 39 → 39 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Oh_leftmixactrreq ROGUE_OH_LEFTMIXACTRREQConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x44 = 68 → 68 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Oh_rearmixactrreq ROGUE_OH_REARMIXACTRREQConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x7F = 127 → 127 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Oh_recyactrreq ROGUE_OH_RECYACTRREQConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x64 = 100 → 100 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Oh_reserveactrreq ROGUE_OH_RESERVEACTRREQConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Oh_rightmixactrreq ROGUE_OH_RIGHTMIXACTRREQConfirmed

  • Service 21PID 53
  • Module744 → 764
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x42 = 66 → 66 %

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Relative Throttle A Position TP_A_RELSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026.

Relative Throttle B Position TP_B_RELSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2010, 2018 to 2020, 2022 to 2023, 2026. Supported for 2014 to 2017, 2021, 2024 to 2025.

Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 08
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2020.

Starter button ROGUE_STARTER_BUTTON

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Starter wear counter ROGUE_STARTER_WEAR_CNT

  • Service 22DID 22AA
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 63 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Tank pressure ROGUE_TANK_P

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val2
Range
0 to 32767
Unit
Raw value

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Throttle opening ROGUE_THROTTLE_OPENING

  • Service 22DID 140F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×720
Range
0 to 89.25 °
Unit
°

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2010, 2018 to 2020. Supported for 2014 to 2017, 2021 to 2026.

Traction control/anti-yaw control ROGUE_TRACTION_CTRL_ANTI

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2010, 2018 to 2020. Supported for 2021 to 2026.

Vapor lock temperature ROGUE_VAPOR_LOCK_T

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Variable valve timing oil temperature ROGUE_VVT_EOT

  • Service 22DID 1266
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3128−273
Range
-273 to 1262 °C
Unit
°C

In testing for 2008 to 2009, 2011 to 2013, 2015 to 2017, 2024. Not supported for 2010, 2014, 2018 to 2023, 2025 to 2026.

Internal

Commanded Throttle Actuator A Control supported? CTAC_A_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Commanded Throttle Actuator B Control supported? CTAC_B_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Relative Throttle A Position data supported? RTP_A_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Relative Throttle B Position data supported? RTP_B_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2010, 2014 to 2015, 2018 to 2020, 2022 to 2023, 2026. Supported for 2016 to 2017, 2021, 2024 to 2025.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 V
Unit
V

Confirmed for 2010, 2018. Supported for 2014 to 2017, 2019 to 2026.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Confirmed for 2010, 2014 to 2015, 2018 to 2020, 2022 to 2023, 2026. Supported for 2016 to 2017, 2021, 2024 to 2025.

Fuel

Air/fuel ratio adjustment, bank 2 ROGUE_AF_ADJ_B2

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 %
Unit
%

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2022, 2026.

Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2022, 2026.

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2022, 2026.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2022, 2026.

Fuel base pulse width ROGUE_FUEL_BASE_WIDTHConfirmed

  • Service 22DID 1208
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val2048
Range
0 to 31.99 ms
Unit
ms

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Fuel level input ROGUE_FLI_INPUT

  • Service 22DID 1114
  • ModuleDA18 → 18
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val25
Range
0 to 10.2 V
Unit
V

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Fuel pump flow ROGUE_FUEL_PMP_FLOW

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val8
Range
0 to 31.87 g/s
Unit
g/s

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Fuel Rail Pressure A FRP_ASAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2022, 2026.

Fuel Rail Pressure B FRP_BSAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2022, 2026.

Fuel rail temperature ROGUE_FUEL_RAIL_T

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Fuel Rail Temperature A FRT_ASAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022, 2026.

Fuel Rail Temperature B FRT_BSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 80 to 87 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022, 2026.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2010, 2018 to 2019, 2022, 2026. Supported for 2014 to 2017, 2020 to 2021, 2023 to 2025.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2010, 2018 to 2019, 2022, 2026. Supported for 2014 to 2017, 2020 to 2021, 2023 to 2025.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2010, 2014 to 2015, 2018 to 2023, 2025 to 2026. Supported for 2016 to 2017, 2024.

Fuel tank temperature ROGUE_FUEL_TANK_T

  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Fuel temperature ROGUE_FUEL_T

  • Service 22DID 1111
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Fuel temperature ROGUE_FUEL_T_7E0Confirmed

  • Service 22DID 1111
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2008 to 2017, 2020 to 2026

Example reply from a 2019 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x2D = 45 → 45−50 = -5 °C

Confirmed for 2018 to 2019. In testing for 2008 to 2017, 2020 to 2026.

Remaining fuel ROGUE_REMAINING_FUEL

  • Service 22DID 1186
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2008 to 2009, 2011 to 2013, 2015 to 2017, 2024. Not supported for 2010, 2014, 2018 to 2023, 2025 to 2026.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2022, 2026.

Internal

Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022, 2026.

Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022, 2026.

Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022, 2026.

Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022, 2026.

Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022, 2026.

Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022, 2026.

Lights

Stop warning light ROGUE_STOP_WARN_LIGHT

  • Service 22DID 2170
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Movement

Change of vehicle speed unit ROGUE_CHANGE_VSS_UNIT

  • Service 22DID 2170
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Cruise control/speed limiter buttons ROGUE_CRUISE_CTRL_SPD

  • Service 22DID 204B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Current engine speed ROGUE_CURRENT_RPMConfirmed

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×252
Range
0 to 819187 rpm
Unit
rpm

0x0037 = 55 → 55×252 = 687.5 rpm

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Engine speed ROGUE_TCM_RPMConfirmed

Pelican can show this parameter as the engine speed.

  • Service 22DID 1204
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0299 = 665 → 665 rpm

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Engine speed, alternate ROGUE_TCM_RPM_2Confirmed

  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x02A6 = 678 → 678 rpm

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Input speed ROGUE_TCM_INPUT_RPMConfirmed

  • Service 22DID 1201
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x029C = 668 → 668 rpm

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Output speed ROGUE_OUTPUT_SPD

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Primary pulley speed ROGUE_TCM_PRI_RPMConfirmed

  • Service 22DID 1202
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Primary pulley speed, alternate ROGUE_TCM_PRI_RPM_2Confirmed

  • Service 22DID 120D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0010 = 16 → 16 rpm

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Secondary pulley speed ROGUE_TCM_SEC_RPMConfirmed

  • Service 22DID 1203
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Secondary pulley speed, alternate ROGUE_TCM_SEC_RPM_2Confirmed

  • Service 22DID 120E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x002B = 43 → 43 rpm

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Turbine speed ROGUE_TURBINE_SPD

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Vehicle speed ROGUE_TCM_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID 1103
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2010, 2018 to 2019, 2022 to 2023, 2025 to 2026. Supported for 2014 to 2017, 2020 to 2021, 2024.

Vehicle speed multiplexed information ROGUE_VSS_MULTIPLEXED

  • Service 22DID 2225
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2010, 2018 to 2019. Supported for 2014 to 2017, 2020 to 2026.

Tires

Front left tire pressure ROGUE_TP_FL_743Confirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 0E26
  • Module743 → 763
  • Every15 s
  • Testing for 2008 to 2017, 2019

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

Confirmed for 2018, 2020 to 2026. In testing for 2008 to 2009, 2011 to 2013, 2017. Not supported for 2010, 2014 to 2016, 2019.

Front left tire pressure ROGUE_TP_FL_V2Confirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 0201
  • Module758 → 778
  • Every5 s
  • Testing for 2008 to 2014, 2017, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

Confirmed for 2015 to 2016, 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014, 2021 to 2024, 2026.

Front left tire pressure, warning ROGUE_TPW_FLConfirmed

  • Service 22DID 020D
  • Module758 → 778
  • Every5 s
  • Testing for 2008 to 2014, 2017, 2021 to 2026

Example reply from a 2020 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

0x6A = 106 → 1064 = 26.5 psi

Confirmed for 2015 to 2016, 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014, 2021 to 2024, 2026.

Front left wheel speed ROGUE_FL_WHL_SPD

  • Service 22DID 4B00
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Front right tire pressure ROGUE_TP_FR_743Confirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 0E25
  • Module743 → 763
  • Every15 s
  • Testing for 2008 to 2017, 2019

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

Confirmed for 2018, 2020 to 2026. In testing for 2008 to 2009, 2011 to 2013, 2017. Not supported for 2010, 2014 to 2016, 2019.

Front right tire pressure ROGUE_TP_FR_V2Confirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 0202
  • Module758 → 778
  • Every5 s
  • Testing for 2008 to 2014, 2017, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

Confirmed for 2015 to 2016, 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014, 2021 to 2024, 2026.

Front right tire pressure, warning ROGUE_TPW_FRConfirmed

  • Service 22DID 020E
  • Module758 → 778
  • Every5 s
  • Testing for 2008 to 2014, 2017, 2021 to 2026

Example reply from a 2020 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

0x6A = 106 → 1064 = 26.5 psi

Confirmed for 2015 to 2016, 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014, 2021 to 2024, 2026.

Front right wheel speed ROGUE_FR_WHL_SPD

  • Service 22DID 4B01
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Rear left tire pressure ROGUE_TP_RL_743Confirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 0E28
  • Module743 → 763
  • Every15 s
  • Testing for 2008 to 2017, 2019

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

Confirmed for 2018, 2020 to 2026. In testing for 2008 to 2009, 2011 to 2013, 2017. Not supported for 2010, 2014 to 2016, 2019.

Rear left tire pressure ROGUE_TP_RL_V2Confirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 0204
  • Module758 → 778
  • Every5 s
  • Testing for 2008 to 2014, 2017, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

Confirmed for 2015 to 2016, 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014, 2021 to 2024, 2026.

Rear left tire pressure, warning ROGUE_TPW_RLConfirmed

  • Service 22DID 0210
  • Module758 → 778
  • Every5 s
  • Testing for 2008 to 2014, 2017, 2021 to 2026

Example reply from a 2020 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

0x6A = 106 → 1064 = 26.5 psi

Confirmed for 2015 to 2016, 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014, 2021 to 2024, 2026.

Rear left wheel speed ROGUE_RL_WHL_SPD

  • Service 22DID 4B02
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Rear right tire pressure ROGUE_TP_RR_743Confirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 0E27
  • Module743 → 763
  • Every15 s
  • Testing for 2008 to 2017, 2019

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

Confirmed for 2018, 2020 to 2026. In testing for 2008 to 2009, 2011 to 2013, 2017. Not supported for 2010, 2014 to 2016, 2019.

Rear right tire pressure ROGUE_TP_RR_V2Confirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 0203
  • Module758 → 778
  • Every5 s
  • Testing for 2008 to 2014, 2017, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

Confirmed for 2015 to 2016, 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014, 2021 to 2024, 2026.

Rear right tire pressure, warning ROGUE_TPW_RRConfirmed

  • Service 22DID 020F
  • Module758 → 778
  • Every5 s
  • Testing for 2008 to 2014, 2017, 2021 to 2026

Example reply from a 2020 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

0x6A = 106 → 1064 = 26.5 psi

Confirmed for 2015 to 2016, 2018 to 2020. In testing for 2008 to 2009, 2011 to 2013, 2017, 2025. Not supported for 2010, 2014, 2021 to 2024, 2026.

Rear right wheel speed ROGUE_RR_WHL_SPD

  • Service 22DID 4B03
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Transmission

Acceleration sensor voltage ROGUE_TCM_G_VConfirmed

  • Service 22DID 1208
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
-3.27 to 3.27 V
Unit
V

0xFF88 = -120 → -12010000 = -0.012 V

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Engage reverse gear ROGUE_ENGAGE_REVERSE_GEAR

  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Engine torque ROGUE_TCM_ENG_TQConfirmed

  • Service 22DID 1214
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

0x002D = 45 → 4510 = 4.5 N·m

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Engine torque, active ROGUE_TCM_ENG_TQ_ACTConfirmed

  • Service 22DID 1212
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

0x0032 = 50 → 5010 = 5 N·m

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Engine torque, transmitted ROGUE_TCM_ENG_TQ_TXConfirmed

  • Service 22DID 1213
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

0x00DC = 220 → 22010 = 22 N·m

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Estimated vehicle speed ROGUE_TCM_VSS_ESTConfirmed

  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Fluid temperature sensor voltage ROGUE_TCM_ATF_T_VConfirmed

  • Service 22DID 1207
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2008 to 2017, 2019 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 320 V
Unit
V

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Gearbox ratio ROGUE_GEARBOX_RAT

  • Service 22DID 2C04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Input speed, alternate ROGUE_TCM_INPUT_RPM_2Confirmed

  • Service 22DID 120C
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0292 = 658 → 658 rpm

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Isolation solenoid 1 current ROGUE_TCM_ISO_1_CConfirmed

  • Service 22DID 1219
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

0x00 = 0 → 01000 = 0 A

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Isolation solenoid 2 current ROGUE_TCM_ISO_2_CConfirmed

  • Service 22DID 121A
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

0x03 = 3 → 31000 = 0.003 A

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Line pressure ROGUE_TCM_LINE_PConfirmed

  • Service 22DID 110E
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

0x2F = 47 → 47×25 = 1,175 kPa

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Lubrication pressure ROGUE_TCM_LUBE_PConfirmed

  • Service 22DID 110D
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270 kPa
Unit
kPa

0xCE = -50 → -50×10 = -500 kPa

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Primary pressure sensor voltage ROGUE_TCM_PRI_P_VConfirmed

  • Service 22DID 1206
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 320 V
Unit
V

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Primary pulley pressure ROGUE_TCM_PRI_P

  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25
Range
0 to 1638375 kPa
Unit
kPa

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Primary pulley torque ROGUE_TCM_PRI_TQConfirmed

  • Service 22DID 1215
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

0x00E6 = 230 → 23010 = 23 N·m

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Primary solenoid current ROGUE_TCM_PRI_SOL_CConfirmed

  • Service 22DID 121B
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

0x03 = 3 → 31000 = 0.003 A

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Primary solenoid monitor current ROGUE_TCM_PRI_SOL_MONConfirmed

  • Service 22DID 1221
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

0x00 = 0 → 01000 = 0 A

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Pulley ratio ROGUE_TCM_PULLEY_RATConfirmed

  • Service 22DID 1210
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55
Unit
Number

0x6A86 = 27270 → 2727010000 = 2.727

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Requested engine speed ROGUE_TCM_REQ_RPMConfirmed

  • Service 22DID 1114
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

0xFE = 254 → 254×50 = 12,700 rpm

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Requested torque ROGUE_TCM_REQ_TQConfirmed

  • Service 22DID 1113
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2+100
Range
-156 to 354 N·m
Unit
N·m

0xFE = -2 → -2×2+100 = 96 N·m

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Requested torque delta ROGUE_TCM_REQ_TQ_DConfirmed

  • Service 22DID 1112
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2+100
Range
-156 to 354 N·m
Unit
N·m

0xFE = -2 → -2×2+100 = 96 N·m

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Secondary pressure sensor voltage ROGUE_TCM_SEC_P_VConfirmed

  • Service 22DID 1205
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 320 V
Unit
V

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Secondary pulley pressure ROGUE_TCM_SEC_P

  • Service 22DID 110A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25
Range
0 to 1638375 kPa
Unit
kPa

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Secondary solenoid current ROGUE_TCM_SEC_SOL_CConfirmed

  • Service 22DID 121C
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

0x03 = 3 → 31000 = 0.003 A

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Secondary solenoid monitor current ROGUE_TCM_SEC_SOL_MONConfirmed

  • Service 22DID 1222
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

0x00 = 0 → 01000 = 0 A

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Select solenoid current ROGUE_TCM_SEL_SOL_CConfirmed

  • Service 22DID 121D
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

0x03 = 3 → 31000 = 0.003 A

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Select solenoid monitor current ROGUE_TCM_SEL_SOL_MONConfirmed

  • Service 22DID 1223
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

0x00 = 0 → 01000 = 0 A

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Solenoid 1 monitor current ROGUE_TCM_SOL_MON_1Confirmed

  • Service 22DID 121E
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

0x00 = 0 → 01000 = 0 A

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Solenoid 2 monitor current ROGUE_TCM_SOL_MON_2Confirmed

  • Service 22DID 121F
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

0x00 = 0 → 01000 = 0 A

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Target primary pulley pressure ROGUE_TCM_PRI_P_TGTConfirmed

  • Service 22DID 110F
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

0x14 = 20 → 20×25 = 500 kPa

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Target pulley ratio ROGUE_TCM_PULLEY_RAT_TGTConfirmed

  • Service 22DID 1218
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55
Unit
Number

0x66C6 = 26310 → 2631010000 = 2.631

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Target secondary pulley pressure ROGUE_TCM_SEC_P_TGTConfirmed

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

0x2C = 44 → 44×25 = 1,100 kPa

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Target select pressure ROGUE_TCM_SEL_P_TGTConfirmed

  • Service 22DID 1110
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

0x00 = 0 → 0×25 = 0 kPa

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Torque converter slip ROGUE_TQ_CONV_SLIP

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Torque ratio ROGUE_TCM_TQ_RATConfirmed

  • Service 22DID 1216
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×577160000
Range
0 to 236
Unit
Number

0x0100 = 256 → 256×577160000 = 0.9232

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Transmission ATF deterioration date ROGUE_TRANS_ATFConfirmed

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00000998 = 2456 → 2,456

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Transmission fluid temperature ROGUE_ATF_T

  • Service 22DID 2170
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Transmission fluid temperature ROGUE_TCM_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x63 = 99 → 99−40 = 59 °C

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Transmission fluid temperature, variant 1 ROGUE_ATF_T_VAR_1

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×95−67
Range
-67 to 392 °F
Unit
°F

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Transmission fluid temperature, variant 2 ROGUE_ATF_T_VAR_2

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×95−67
Range
-67 to 392 °F
Unit
°F

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Transmission work hours ROGUE_TRANS_WORK_HOURS

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val6
Range
0 to 10922 h
Unit
h

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Transmission work hours warm engine ROGUE_TRANS_WORK_HOURS_WARM_ENG

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val6
Range
0 to 10922 h
Unit
h

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Transmission-A ROGUE_TRANS

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Transmission-B ROGUE_TRANS_B

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Vehicle speed sensor ROGUE_TCM_VSS_SENSConfirmed

  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Trips

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2021 to 2023, 2025 to 2026.

Odometer ROGUE_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 0E01
  • Module743 → 763
  • Every1 s
  • Testing for 2008 to 2017, 2019

Example reply from a 2026 Nissan Rogue Select.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 mi
Unit
mi

0x0001B0 = 432 → 432 mi

Confirmed for 2018, 2020 to 2026. In testing for 2008 to 2009, 2011 to 2013, 2017. Not supported for 2010, 2014 to 2016, 2019.

Odometer ROGUE_ODO_METERConfirmed

Pelican can show this parameter as the odometer.

  • Service 21PID 01
  • Module743 → 763
  • Every30 s
  • Testing for 2008 to 2017, 2019 to 2026

Example reply from a 2018 Nissan Rogue Select.

Bits 56 to 79 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x02ED49 = 191817 → 191,817 km

Confirmed for 2018. In testing for 2008 to 2017, 2019 to 2026.

Range shown on the display ROGUE_RANGE_DISP

Pelican can show this parameter as the fuel range.

  • Service 22DID 1155
  • Module797 → 79A
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2008 to 2017, 2019 to 2026. Not supported for 2018.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.