Parameters
The Nissan Pulsar has 20 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Climate
Air conditioning compressor speed PULSAR_AC_COMP_RPM
- Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 1996 to 2005, 2014 to 2018.
Air conditioning on PULSAR_HVAC_AC_ON
- Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bit 80 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2005, 2014 to 2018.
Air conditioning status PULSAR_AC_STATUS
- Service 22
DID 4007 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2014 to 2018.
Ambient air temperature PULSAR_AAT
- Service 22
DID 4008 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2005, 2014 to 2018.
Ambient air temperature, climate module PULSAR_HVAC_AAT
- Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2005, 2014 to 2018.
Blower on PULSAR_HVAC_FAN_ON
- Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bit 88 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1996 to 2005, 2014 to 2018.
Blower voltage PULSAR_HVAC_BLOWER_V
- Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 89 to 95 of the reply, 7 bits.
- Formula
- Range
- 0 to 127 V
- Unit
- V
In testing for 1996 to 2005, 2014 to 2018.
Cabin temperature PULSAR_HVAC_CABIN_T
- Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2005, 2014 to 2018.
Engine coolant temperature PULSAR_ECT
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID F467 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 214 °C
- Unit
- °C
In testing for 1996 to 2005, 2014 to 2018.
Evaporator temperature PULSAR_HVAC_EVAP_T
- Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1996 to 2005, 2014 to 2018.
Sun load PULSAR_HVAC_SUNLOAD
- Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1996 to 2005, 2014 to 2018.
Control
Accelerator pedal position PULSAR_APP
- Service 22
DID 1115 - Module
740 → 760 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 1996 to 2005, 2014 to 2018.
Brake master cylinder pressure count PULSAR_BRAKE_MC_P
- Service 22
DID 1209 - Module
740 → 760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 1996 to 2005, 2014 to 2018.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2015. Supported for 2017.
Engine
Air conditioning compressor PULSAR_AC_COMP
- Service 22
DID 1307 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2014 to 2018.
Cooling fan high PULSAR_COOLING_FAN_HIGH
- Service 22
DID 1313 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2014 to 2018.
Cooling fan low PULSAR_COOLING_FAN_LOW
- Service 22
DID 1313 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2014 to 2018.
Idle control mode PULSAR_IDLE_CTRL_MODE
- Service 22
DID 1307 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 1996 to 2005, 2014 to 2018.
Variable valve timing oil temperature PULSAR_VVT_OIL_T
- Service 22
DID 1266 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 1262 °C
- Unit
- °C
In testing for 1996 to 2005, 2014 to 2018.
Fuel
Remaining fuel PULSAR_FUEL_REMAINING
- Service 22
DID 1186 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 L
- Unit
- L
In testing for 1996 to 2005, 2014 to 2018.