Nissan ARIYA

Parameters

The Nissan ARIYA has 586 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Front left tire pressure ARIYA_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 0E26
  • Module743 → 763
  • Every15 s
  • Testing for 2022, 2026

Example reply from a 2025 Nissan ARIYA.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.7236894
Range
0 to 439.5 kPa
Unit
kPa

0x84 = 132 → 132×1.7236894 = 227.527001 kPa

Confirmed for 2023 to 2025. In testing for 2022, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Absolute time since first ignition ARIYA_ABS_TIME_SINCE_FIRST

  • Service 22DID 9261
  • ModuleDADB → DAF1DB
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2022 to 2026.

Bus bar 1 flag ARIYA_BUSBAR_NO_1

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Bus bar 1 voltage ARIYA_BUSBAR_V_NO_1

  • Service 22DID 9221
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2022 to 2026.

Bus bar 2 flag ARIYA_BUSBAR_NO_2

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Bus bar 2 voltage ARIYA_BUSBAR_V_NO_2

  • Service 22DID 9222
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2022 to 2026.

Bus bar 3 flag ARIYA_BUSBAR_NO_3

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Bus bar 3 voltage ARIYA_BUSBAR_V_NO_3

  • Service 22DID 9223
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2022 to 2026.

Bus bar 4 flag ARIYA_BUSBAR_NO_4

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Bus bar 4 voltage ARIYA_BUSBAR_V_NO_4

  • Service 22DID 9224
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2022 to 2026.

Bus bar 5 flag ARIYA_BUSBAR_NO_5

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Bus bar 5 voltage ARIYA_BUSBAR_V_NO_5

  • Service 22DID 9225
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2022 to 2026.

Bus bar 6 flag ARIYA_BUSBAR_NO_6

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Bus bar 6 voltage ARIYA_BUSBAR_V_NO_6

  • Service 22DID 9226
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2022 to 2026.

Bus bar 7 flag ARIYA_BUSBAR_NO_7

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Bus bar 7 voltage ARIYA_BUSBAR_V_NO_7

  • Service 22DID 9227
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2022 to 2026.

Bus bar 8 flag ARIYA_BUSBAR_NO_8

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Bus bar 8 voltage ARIYA_BUSBAR_V_NO_8

  • Service 22DID 9228
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2022 to 2026.

Bus bar 9 flag ARIYA_BUSBAR_NO_9

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Bus bar 10 flag ARIYA_BUSBAR_NO_10

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Bus bar 11 flag ARIYA_BUSBAR_NO_11

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Bus bar 12 flag ARIYA_BUSBAR_NO_12

  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 1 flag ARIYA_CELL_NUMBER_1

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 255 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 1 state of health flag ARIYA_SOH_CELL_1

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 255 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 1 voltage ARIYA_HVBAT_CELL_1_V

  • Service 22DID 9021
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 2 flag ARIYA_CELL_NUMBER_2

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 254 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 2 state of health flag ARIYA_SOH_CELL_2

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 254 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 2 voltage ARIYA_HVBAT_CELL_2_V

  • Service 22DID 9022
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 3 flag ARIYA_CELL_NUMBER_3

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 253 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 3 state of health flag ARIYA_SOH_CELL_3

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 253 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 3 voltage ARIYA_HVBAT_CELL_3_V

  • Service 22DID 9023
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 4 flag ARIYA_CELL_NUMBER_4

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 252 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 4 state of health flag ARIYA_SOH_CELL_4

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 252 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 4 voltage ARIYA_HVBAT_CELL_4_V

  • Service 22DID 9024
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 5 flag ARIYA_CELL_NUMBER_5

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 251 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 5 state of health flag ARIYA_SOH_CELL_5

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 251 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 5 voltage ARIYA_HVBAT_CELL_5_V

  • Service 22DID 9025
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 6 flag ARIYA_CELL_NUMBER_6

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 250 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 6 state of health flag ARIYA_SOH_CELL_6

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 250 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 6 voltage ARIYA_HVBAT_CELL_6_V

  • Service 22DID 9026
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 7 flag ARIYA_CELL_NUMBER_7

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 249 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 7 state of health flag ARIYA_SOH_CELL_7

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 249 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 7 voltage ARIYA_HVBAT_CELL_7_V

  • Service 22DID 9027
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 8 flag ARIYA_CELL_NUMBER_8

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 248 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 8 state of health flag ARIYA_SOH_CELL_8

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 248 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 8 voltage ARIYA_HVBAT_CELL_8_V

  • Service 22DID 9028
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 9 flag ARIYA_CELL_NUMBER_9

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 247 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 9 state of health flag ARIYA_SOH_CELL_9

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 247 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 9 voltage ARIYA_HVBAT_CELL_9_V

  • Service 22DID 9029
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 10 flag ARIYA_CELL_NUMBER_10

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 246 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 10 state of health flag ARIYA_SOH_CELL_10

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 246 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 10 voltage ARIYA_HVBAT_CELL_10_V

  • Service 22DID 902A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 11 flag ARIYA_CELL_NUMBER_11

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 245 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 11 state of health flag ARIYA_SOH_CELL_11

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 245 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 11 voltage ARIYA_HVBAT_CELL_11_V

  • Service 22DID 902B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 12 flag ARIYA_CELL_NUMBER_12

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 244 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 12 state of health flag ARIYA_SOH_CELL_12

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 244 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 12 voltage ARIYA_HVBAT_CELL_12_V

  • Service 22DID 902C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 13 flag ARIYA_CELL_NUMBER_13

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 243 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 13 state of health flag ARIYA_SOH_CELL_13

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 243 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 13 voltage ARIYA_HVBAT_CELL_13_V

  • Service 22DID 902D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 14 flag ARIYA_CELL_NUMBER_14

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 242 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 14 state of health flag ARIYA_SOH_CELL_14

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 242 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 14 voltage ARIYA_HVBAT_CELL_14_V

  • Service 22DID 902E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 15 flag ARIYA_CELL_NUMBER_15

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 241 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 15 state of health flag ARIYA_SOH_CELL_15

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 241 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 15 voltage ARIYA_HVBAT_CELL_15_V

  • Service 22DID 902F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 16 flag ARIYA_CELL_NUMBER_16

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 240 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 16 state of health flag ARIYA_SOH_CELL_16

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 240 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 16 voltage ARIYA_HVBAT_CELL_16_V

  • Service 22DID 9030
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 17 flag ARIYA_CELL_NUMBER_17

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 239 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 17 state of health flag ARIYA_SOH_CELL_17

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 239 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 17 voltage ARIYA_HVBAT_CELL_17_V

  • Service 22DID 9031
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 18 flag ARIYA_CELL_NUMBER_18

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 238 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 18 state of health flag ARIYA_SOH_CELL_18

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 238 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 18 voltage ARIYA_HVBAT_CELL_18_V

  • Service 22DID 9032
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 19 flag ARIYA_CELL_NUMBER_19

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 237 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 19 state of health flag ARIYA_SOH_CELL_19

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 237 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 19 voltage ARIYA_HVBAT_CELL_19_V

  • Service 22DID 9033
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 20 flag ARIYA_CELL_NUMBER_20

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 236 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 20 state of health flag ARIYA_SOH_CELL_20

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 236 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 20 voltage ARIYA_HVBAT_CELL_20_V

  • Service 22DID 9034
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 21 flag ARIYA_CELL_NUMBER_21

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 235 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 21 state of health flag ARIYA_SOH_CELL_21

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 235 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 21 voltage ARIYA_HVBAT_CELL_21_V

  • Service 22DID 9035
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 22 flag ARIYA_CELL_NUMBER_22

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 234 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 22 state of health flag ARIYA_SOH_CELL_22

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 234 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 22 voltage ARIYA_HVBAT_CELL_22_V

  • Service 22DID 9036
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 23 flag ARIYA_CELL_NUMBER_23

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 233 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 23 state of health flag ARIYA_SOH_CELL_23

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 233 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 23 voltage ARIYA_HVBAT_CELL_23_V

  • Service 22DID 9037
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 24 flag ARIYA_CELL_NUMBER_24

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 232 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 24 state of health flag ARIYA_SOH_CELL_24

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 232 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 24 voltage ARIYA_HVBAT_CELL_24_V

  • Service 22DID 9038
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 25 flag ARIYA_CELL_NUMBER_25

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 231 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 25 state of health flag ARIYA_SOH_CELL_25

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 231 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 25 voltage ARIYA_HVBAT_CELL_25_V

  • Service 22DID 9039
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 26 flag ARIYA_CELL_NUMBER_26

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 230 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 26 state of health flag ARIYA_SOH_CELL_26

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 230 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 26 voltage ARIYA_HVBAT_CELL_26_V

  • Service 22DID 903A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 27 flag ARIYA_CELL_NUMBER_27

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 229 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 27 state of health flag ARIYA_SOH_CELL_27

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 229 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 27 voltage ARIYA_HVBAT_CELL_27_V

  • Service 22DID 903B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 28 flag ARIYA_CELL_NUMBER_28

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 228 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 28 state of health flag ARIYA_SOH_CELL_28

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 228 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 28 voltage ARIYA_HVBAT_CELL_28_V

  • Service 22DID 903C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 29 flag ARIYA_CELL_NUMBER_29

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 227 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 29 state of health flag ARIYA_SOH_CELL_29

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 227 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 29 voltage ARIYA_HVBAT_CELL_29_V

  • Service 22DID 903D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 30 flag ARIYA_CELL_NUMBER_30

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 226 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 30 state of health flag ARIYA_SOH_CELL_30

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 226 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 30 voltage ARIYA_HVBAT_CELL_30_V

  • Service 22DID 903E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 31 flag ARIYA_CELL_NUMBER_31

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 225 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 31 state of health flag ARIYA_SOH_CELL_31

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 225 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 31 voltage ARIYA_HVBAT_CELL_31_V

  • Service 22DID 903F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 32 flag ARIYA_CELL_NUMBER_32

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 224 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 32 state of health flag ARIYA_SOH_CELL_32

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 224 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 32 voltage ARIYA_HVBAT_CELL_32_V

  • Service 22DID 9041
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 33 flag ARIYA_CELL_NUMBER_33

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 223 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 33 state of health flag ARIYA_SOH_CELL_33

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 223 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 33 voltage ARIYA_HVBAT_CELL_33_V

  • Service 22DID 9042
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 34 flag ARIYA_CELL_NUMBER_34

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 222 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 34 state of health flag ARIYA_SOH_CELL_34

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 222 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 34 voltage ARIYA_HVBAT_CELL_34_V

  • Service 22DID 9043
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 35 flag ARIYA_CELL_NUMBER_35

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 221 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 35 state of health flag ARIYA_SOH_CELL_35

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 221 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 35 voltage ARIYA_HVBAT_CELL_35_V

  • Service 22DID 9044
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 36 flag ARIYA_CELL_NUMBER_36

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 220 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 36 state of health flag ARIYA_SOH_CELL_36

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 220 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 36 voltage ARIYA_HVBAT_CELL_36_V

  • Service 22DID 9045
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 37 flag ARIYA_CELL_NUMBER_37

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 219 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 37 state of health flag ARIYA_SOH_CELL_37

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 219 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 37 voltage ARIYA_HVBAT_CELL_37_V

  • Service 22DID 9046
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 38 flag ARIYA_CELL_NUMBER_38

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 218 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 38 state of health flag ARIYA_SOH_CELL_38

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 218 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 38 voltage ARIYA_HVBAT_CELL_38_V

  • Service 22DID 9047
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 39 flag ARIYA_CELL_NUMBER_39

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 217 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 39 state of health flag ARIYA_SOH_CELL_39

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 217 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 39 voltage ARIYA_HVBAT_CELL_39_V

  • Service 22DID 9048
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 40 flag ARIYA_CELL_NUMBER_40

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 216 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 40 state of health flag ARIYA_SOH_CELL_40

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 216 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 40 voltage ARIYA_HVBAT_CELL_40_V

  • Service 22DID 9049
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 41 flag ARIYA_CELL_NUMBER_41

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 215 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 41 state of health flag ARIYA_SOH_CELL_41

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 215 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 41 voltage ARIYA_HVBAT_CELL_41_V

  • Service 22DID 904A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 42 flag ARIYA_CELL_NUMBER_42

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 214 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 42 state of health flag ARIYA_SOH_CELL_42

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 214 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 42 voltage ARIYA_HVBAT_CELL_42_V

  • Service 22DID 904B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 43 flag ARIYA_CELL_NUMBER_43

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 213 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 43 state of health flag ARIYA_SOH_CELL_43

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 213 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 43 voltage ARIYA_HVBAT_CELL_43_V

  • Service 22DID 904C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 44 flag ARIYA_CELL_NUMBER_44

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 212 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 44 state of health flag ARIYA_SOH_CELL_44

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 212 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 44 voltage ARIYA_HVBAT_CELL_44_V

  • Service 22DID 904D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 45 flag ARIYA_CELL_NUMBER_45

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 211 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 45 state of health flag ARIYA_SOH_CELL_45

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 211 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 45 voltage ARIYA_HVBAT_CELL_45_V

  • Service 22DID 904E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 46 flag ARIYA_CELL_NUMBER_46

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 210 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 46 state of health flag ARIYA_SOH_CELL_46

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 210 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 46 voltage ARIYA_HVBAT_CELL_46_V

  • Service 22DID 904F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 47 flag ARIYA_CELL_NUMBER_47

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 209 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 47 state of health flag ARIYA_SOH_CELL_47

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 209 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 47 voltage ARIYA_HVBAT_CELL_47_V

  • Service 22DID 9050
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 48 flag ARIYA_CELL_NUMBER_48

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 208 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 48 state of health flag ARIYA_SOH_CELL_48

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 208 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 48 voltage ARIYA_HVBAT_CELL_48_V

  • Service 22DID 9051
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 49 flag ARIYA_CELL_NUMBER_49

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 49 state of health flag ARIYA_SOH_CELL_49

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 49 voltage ARIYA_HVBAT_CELL_49_V

  • Service 22DID 9052
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 50 flag ARIYA_CELL_NUMBER_50

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 206 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 50 state of health flag ARIYA_SOH_CELL_50

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 206 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 50 voltage ARIYA_HVBAT_CELL_50_V

  • Service 22DID 9053
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 51 flag ARIYA_CELL_NUMBER_51

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 205 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 51 state of health flag ARIYA_SOH_CELL_51

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 205 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 51 voltage ARIYA_HVBAT_CELL_51_V

  • Service 22DID 9054
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 52 flag ARIYA_CELL_NUMBER_52

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 204 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 52 state of health flag ARIYA_SOH_CELL_52

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 204 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 52 voltage ARIYA_HVBAT_CELL_52_V

  • Service 22DID 9055
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 53 flag ARIYA_CELL_NUMBER_53

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 203 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 53 state of health flag ARIYA_SOH_CELL_53

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 203 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 53 voltage ARIYA_HVBAT_CELL_53_V

  • Service 22DID 9056
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 54 flag ARIYA_CELL_NUMBER_54

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 202 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 54 state of health flag ARIYA_SOH_CELL_54

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 202 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 54 voltage ARIYA_HVBAT_CELL_54_V

  • Service 22DID 9057
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 55 flag ARIYA_CELL_NUMBER_55

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 201 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 55 state of health flag ARIYA_SOH_CELL_55

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 201 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 55 voltage ARIYA_HVBAT_CELL_55_V

  • Service 22DID 9058
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 56 flag ARIYA_CELL_NUMBER_56

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 200 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 56 state of health flag ARIYA_SOH_CELL_56

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 200 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 56 voltage ARIYA_HVBAT_CELL_56_V

  • Service 22DID 9059
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 57 flag ARIYA_CELL_NUMBER_57

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 199 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 57 state of health flag ARIYA_SOH_CELL_57

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 199 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 57 voltage ARIYA_HVBAT_CELL_57_V

  • Service 22DID 905A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 58 flag ARIYA_CELL_NUMBER_58

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 198 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 58 state of health flag ARIYA_SOH_CELL_58

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 198 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 58 voltage ARIYA_HVBAT_CELL_58_V

  • Service 22DID 905B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 59 flag ARIYA_CELL_NUMBER_59

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 197 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 59 state of health flag ARIYA_SOH_CELL_59

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 197 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 59 voltage ARIYA_HVBAT_CELL_59_V

  • Service 22DID 905C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 60 flag ARIYA_CELL_NUMBER_60

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 196 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 60 state of health flag ARIYA_SOH_CELL_60

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 196 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 60 voltage ARIYA_HVBAT_CELL_60_V

  • Service 22DID 905D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 61 flag ARIYA_CELL_NUMBER_61

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 195 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 61 state of health flag ARIYA_SOH_CELL_61

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 195 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 61 voltage ARIYA_HVBAT_CELL_61_V

  • Service 22DID 905E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 62 flag ARIYA_CELL_NUMBER_62

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 194 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 62 state of health flag ARIYA_SOH_CELL_62

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 194 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 62 voltage ARIYA_HVBAT_CELL_62_V

  • Service 22DID 905F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 63 flag ARIYA_CELL_NUMBER_63

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 193 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 63 state of health flag ARIYA_SOH_CELL_63

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 193 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 63 voltage ARIYA_HVBAT_CELL_63_V

  • Service 22DID 9061
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 64 flag ARIYA_CELL_NUMBER_64

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 192 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 64 state of health flag ARIYA_SOH_CELL_64

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 192 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 64 voltage ARIYA_HVBAT_CELL_64_V

  • Service 22DID 9062
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 65 flag ARIYA_CELL_NUMBER_65

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 191 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 65 state of health flag ARIYA_SOH_CELL_65

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 191 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 65 voltage ARIYA_HVBAT_CELL_65_V

  • Service 22DID 9063
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 66 flag ARIYA_CELL_NUMBER_66

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 190 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 66 state of health flag ARIYA_SOH_CELL_66

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 190 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 66 voltage ARIYA_HVBAT_CELL_66_V

  • Service 22DID 9064
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 67 flag ARIYA_CELL_NUMBER_67

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 189 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 67 state of health flag ARIYA_SOH_CELL_67

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 189 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 67 voltage ARIYA_HVBAT_CELL_67_V

  • Service 22DID 9065
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 68 flag ARIYA_CELL_NUMBER_68

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 188 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 68 state of health flag ARIYA_SOH_CELL_68

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 188 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 68 voltage ARIYA_HVBAT_CELL_68_V

  • Service 22DID 9066
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 69 flag ARIYA_CELL_NUMBER_69

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 187 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 69 state of health flag ARIYA_SOH_CELL_69

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 187 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 69 voltage ARIYA_HVBAT_CELL_69_V

  • Service 22DID 9067
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 70 flag ARIYA_CELL_NUMBER_70

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 186 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 70 state of health flag ARIYA_SOH_CELL_70

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 186 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 70 voltage ARIYA_HVBAT_CELL_70_V

  • Service 22DID 9068
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 71 flag ARIYA_CELL_NUMBER_71

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 185 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 71 state of health flag ARIYA_SOH_CELL_71

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 185 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 71 voltage ARIYA_HVBAT_CELL_71_V

  • Service 22DID 9069
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 72 flag ARIYA_CELL_NUMBER_72

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 184 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 72 state of health flag ARIYA_SOH_CELL_72

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 184 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 72 voltage ARIYA_HVBAT_CELL_72_V

  • Service 22DID 906A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 73 flag ARIYA_CELL_NUMBER_73

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 73 state of health flag ARIYA_SOH_CELL_73

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 73 voltage ARIYA_HVBAT_CELL_73_V

  • Service 22DID 906B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 74 flag ARIYA_CELL_NUMBER_74

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 74 state of health flag ARIYA_SOH_CELL_74

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 74 voltage ARIYA_HVBAT_CELL_74_V

  • Service 22DID 906C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 75 flag ARIYA_CELL_NUMBER_75

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 75 state of health flag ARIYA_SOH_CELL_75

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 75 voltage ARIYA_HVBAT_CELL_75_V

  • Service 22DID 906D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 76 flag ARIYA_CELL_NUMBER_76

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 76 state of health flag ARIYA_SOH_CELL_76

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 76 voltage ARIYA_HVBAT_CELL_76_V

  • Service 22DID 906E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 77 flag ARIYA_CELL_NUMBER_77

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 77 state of health flag ARIYA_SOH_CELL_77

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 77 voltage ARIYA_HVBAT_CELL_77_V

  • Service 22DID 906F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 78 flag ARIYA_CELL_NUMBER_78

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 177 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 78 state of health flag ARIYA_SOH_CELL_78

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 78 voltage ARIYA_HVBAT_CELL_78_V

  • Service 22DID 9070
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 79 state of health flag ARIYA_SOH_CELL_79

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 177 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 79 voltage ARIYA_HVBAT_CELL_79_V

  • Service 22DID 9071
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 80 flag ARIYA_CELL_NUMBER_80

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 176 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 80 state of health flag ARIYA_SOH_CELL_80

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 176 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 80 voltage ARIYA_HVBAT_CELL_80_V

  • Service 22DID 9072
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 81 flag ARIYA_CELL_NUMBER_81

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 81 state of health flag ARIYA_SOH_CELL_81

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 81 voltage ARIYA_HVBAT_CELL_81_V

  • Service 22DID 9073
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 82 flag ARIYA_CELL_NUMBER_82

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 174 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 82 state of health flag ARIYA_SOH_CELL_82

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 174 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 82 voltage ARIYA_HVBAT_CELL_82_V

  • Service 22DID 9074
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 83 flag ARIYA_CELL_NUMBER_83

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 173 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 83 state of health flag ARIYA_SOH_CELL_83

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 173 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 83 voltage ARIYA_HVBAT_CELL_83_V

  • Service 22DID 9075
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 84 flag ARIYA_CELL_NUMBER_84

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 172 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 84 state of health flag ARIYA_SOH_CELL_84

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 172 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 84 voltage ARIYA_HVBAT_CELL_84_V

  • Service 22DID 9076
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 85 flag ARIYA_CELL_NUMBER_85

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 85 state of health flag ARIYA_SOH_CELL_85

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 85 voltage ARIYA_HVBAT_CELL_85_V

  • Service 22DID 9077
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 86 flag ARIYA_CELL_NUMBER_86

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 86 state of health flag ARIYA_SOH_CELL_86

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 86 voltage ARIYA_HVBAT_CELL_86_V

  • Service 22DID 9078
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 87 flag ARIYA_CELL_NUMBER_87

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 169 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 87 state of health flag ARIYA_SOH_CELL_87

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 169 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 87 voltage ARIYA_HVBAT_CELL_87_V

  • Service 22DID 9079
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 88 flag ARIYA_CELL_NUMBER_88

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 168 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 88 state of health flag ARIYA_SOH_CELL_88

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 168 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 88 voltage ARIYA_HVBAT_CELL_88_V

  • Service 22DID 907A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 89 flag ARIYA_CELL_NUMBER_89

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 167 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 89 state of health flag ARIYA_SOH_CELL_89

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 167 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 89 voltage ARIYA_HVBAT_CELL_89_V

  • Service 22DID 907B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 90 flag ARIYA_CELL_NUMBER_90

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 166 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 90 state of health flag ARIYA_SOH_CELL_90

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 166 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 90 voltage ARIYA_HVBAT_CELL_90_V

  • Service 22DID 907C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 91 flag ARIYA_CELL_NUMBER_91

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 165 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 91 state of health flag ARIYA_SOH_CELL_91

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 165 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 91 voltage ARIYA_HVBAT_CELL_91_V

  • Service 22DID 907D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 92 flag ARIYA_CELL_NUMBER_92

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 164 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 92 state of health flag ARIYA_SOH_CELL_92

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 164 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 92 voltage ARIYA_HVBAT_CELL_92_V

  • Service 22DID 907E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 93 flag ARIYA_CELL_NUMBER_93

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 163 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 93 state of health flag ARIYA_SOH_CELL_93

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 163 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 93 voltage ARIYA_HVBAT_CELL_93_V

  • Service 22DID 907F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 94 flag ARIYA_CELL_NUMBER_94

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 162 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 94 state of health flag ARIYA_SOH_CELL_94

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 162 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 94 voltage ARIYA_HVBAT_CELL_94_V

  • Service 22DID 9081
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 95 flag ARIYA_CELL_NUMBER_95

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 161 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 95 state of health flag ARIYA_SOH_CELL_95

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 161 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 95 voltage ARIYA_HVBAT_CELL_95_V

  • Service 22DID 9082
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell 96 flag ARIYA_CELL_NUMBER_96

  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 160 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 96 state of health flag ARIYA_SOH_CELL_96

  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 160 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cell 96 voltage ARIYA_HVBAT_CELL_96_V

  • Service 22DID 9083
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Cell with the highest voltage ARIYA_CELL_HIGHEST_V

  • Service 22DID 9008
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2022 to 2026.

Cell with the lowest voltage ARIYA_CELL_LOWEST_V

  • Service 22DID 900A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2022 to 2026.

Cells overvoltage ARIYA_CELLS_OVERVOLAGE

  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Cells undervoltage ARIYA_CELLS_UNDERVOLTAGE

  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Computer power supply ARIYA_COMPUTER_POWER_SUP

  • Service 22DID 9011
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2023 to 2025.

Cumulative energy when discharging ARIYA_CUM_ENERGY

  • Service 22DID 9245
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-2147483 to 2147483 kWh
Unit
kWh

In testing for 2022 to 2026.

DC battery capacity ARIYA_DC_BAT_CAP

  • Service 22DID 91C8
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777 kWh
Unit
kWh

In testing for 2022 to 2026.

DC battery current ARIYA_DC_BAT_CURRENT

  • Service 22DID 21CC
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×-14+500
Range
-15883 to 500 A
Unit
A

In testing for 2022 to 2026.

DC battery state of charge ARIYA_DC_BAT_ST_CHG

  • Service 22DID 9002
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2022 to 2026.

DC battery state of health ARIYA_DC_BAT_ST_HEALTH

  • Service 22DID 9003
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 %
Unit
%

In testing for 2022 to 2026.

DC battery voltage ARIYA_DC_BAT_V

  • Service 22DID 20FE
  • ModuleDADA → DAF1DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2022 to 2026.

Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 13 to 14 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode
2CIMCharge increasing mode
3Not PSA

Confirmed for 2023 to 2025.

Fan unit ARIYA_FAN_UNIT

  • Service 22DID 91EF
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2022 to 2026.

Fan unit feed ARIYA_FAN_UNIT_FEED

  • Service 22DID 925A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 Hz
Unit
Hz

In testing for 2022 to 2026.

Fault finding version ARIYA_FAULT_FINDING

  • Service 22DID F1A0
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2026.

Highest cell voltage level ARIYA_HIGHEST_CELL_V_LEVEL

  • Service 22DID 9007
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2025.

Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2023 to 2025.

Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.98 V
Unit
V

Confirmed for 2023 to 2025.

Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 15 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode

Confirmed for 2023 to 2025.

Lowest cell voltage level ARIYA_LOWEST_CELL_V_LEVEL

  • Service 22DID 9009
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2022 to 2026.

Module 1 temperature ARIYA_MODULE_T_NUMBER_1

  • Service 22DID 9131
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Module 1 temperature sensor flag ARIYA_T_SENS_MODULE_N_1

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Module 2 temperature ARIYA_MODULE_T_NUMBER_2

  • Service 22DID 9132
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Module 2 temperature sensor flag ARIYA_T_SENS_MODULE_N_2

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Module 3 temperature ARIYA_MODULE_T_NUMBER_3

  • Service 22DID 9133
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Module 3 temperature sensor flag ARIYA_T_SENS_MODULE_N_3

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Module 4 temperature ARIYA_MODULE_T_NUMBER_4

  • Service 22DID 9134
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Module 4 temperature sensor flag ARIYA_T_SENS_MODULE_N_4

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Module 5 temperature ARIYA_MODULE_T_NUMBER_5

  • Service 22DID 9135
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Module 5 temperature sensor flag ARIYA_T_SENS_MODULE_N_5

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Module 6 temperature ARIYA_MODULE_T_NUMBER_6

  • Service 22DID 9136
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Module 6 temperature sensor flag ARIYA_T_SENS_MODULE_N_6

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Module 7 temperature ARIYA_MODULE_T_NUMBER_7

  • Service 22DID 9137
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Module 7 temperature sensor flag ARIYA_T_SENS_MODULE_N_7

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Module 8 temperature ARIYA_MODULE_T_NUMBER_8

  • Service 22DID 9138
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Module 8 temperature sensor flag ARIYA_T_SENS_MODULE_N_8

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Module 9 temperature ARIYA_MODULE_T_NUMBER_9

  • Service 22DID 9139
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Module 9 temperature sensor flag ARIYA_T_SENS_MODULE_N_9

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Module 10 temperature ARIYA_MODULE_T_NUMBER_10

  • Service 22DID 913A
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Module 10 temperature sensor flag ARIYA_T_SENS_MODULE_N_10

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Module 11 temperature ARIYA_MODULE_T_NUMBER_11

  • Service 22DID 913B
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Module 11 temperature sensor flag ARIYA_T_SENS_MODULE_N_11

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Module 12 temperature ARIYA_MODULE_T_NUMBER_12

  • Service 22DID 913C
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Module 12 temperature sensor flag ARIYA_T_SENS_MODULE_N_12

  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Module with the minimum temperature ARIYA_MODULE_MIN_T

  • Service 22DID 9242
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2026.

Motor-driven fan unit request ARIYA_MOTOR_DRIVEN_FAN

  • Service 22DID 91C9
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2022 to 2026.

Open circuit voltage ARIYA_OPEN_CIRCUIT_V

  • Service 22DID 9005
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2022 to 2026.

Secondary battery management board 1 ARIYA_SECONDARY_BMS_NO_1

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Secondary battery management board 2 ARIYA_SECONDARY_BMS_NO_2

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Secondary battery management board 3 ARIYA_SECONDARY_BMS_NO_3

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Secondary battery management board 4 ARIYA_SECONDARY_BMS_NO_4

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Secondary battery management board 5 ARIYA_SECONDARY_BMS_NO_5

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Secondary battery management board 6 ARIYA_SECONDARY_BMS_NO_6

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Secondary battery management board 7 ARIYA_SECONDARY_BMS_NO_7

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Secondary battery management board 8 ARIYA_SECONDARY_BMS_NO_8

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Secondary battery management board 9 ARIYA_SECONDARY_BMS_NO_9

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Secondary battery management board 10 ARIYA_SECONDARY_BMS_NO_10

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Secondary battery management board 11 ARIYA_SECONDARY_BMS_NO_11

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Secondary battery management board 12 ARIYA_SECONDARY_BMS_NO_12

  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Traction battery compartment temperature ARIYA_TRACTION_BAT_T

  • Service 22DID 9012
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Traction battery current ARIYA_TRACTION_BAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Service 22DID 9284
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×-11000
Range
-2147483 to 2147483 A
Unit
A

In testing for 2022 to 2026.

Traction battery input water temperature ARIYA_TRACTION_BAT_INPUT_T

  • Service 22DID 91CD
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Traction battery interlock ARIYA_TRACTION_BAT_INTERLOCK

  • Service 22DID 91F7
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2026.

Traction battery maximum temperature ARIYA_TRACTION_BAT_MAX_T

  • Service 22DID 9014
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Traction battery minimum temperature ARIYA_TRACTION_BAT_MIN_T

  • Service 22DID 9013
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2022 to 2026.

Traction battery overcurrent ARIYA_TRACTION_BAT_OVERCURRENT

  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Traction battery overheating ARIYA_TRACTION_BAT

  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2022 to 2026.

Traction battery service plug interlock ARIYA_TRACTION_BAT_SERVICE

  • Service 22DID 91F6
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2026.

Traction battery state of charge ARIYA_TRACTION_BAT_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 9001
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−3
Range
-3 to 652 %
Unit
%

In testing for 2022 to 2026.

Traction battery total mileage ARIYA_TRACTION_BAT_TOT

  • Service 22DID 91CF
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val32+67108864
Range
0 to 134217727 km
Unit
km

In testing for 2022 to 2026.

Traction battery voltage ARIYA_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 9006
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1024
Range
0 to 1000 V
Unit
V

In testing for 2022 to 2026.

Internal

Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Climate

Air conditioning compressor speed ARIYA_AC_COMP_RPM

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2022 to 2026.

Air conditioning on ARIYA_HVAC_AC_ON

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 80 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2022 to 2026.

Air conditioning status ARIYA_AC_STATUSConfirmed

  • Service 22DID 4007
  • Module744 → 764
  • Every5 s
  • Testing for 2022, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Off or on

Confirmed for 2023 to 2025. In testing for 2022, 2026.

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. Supported for 2023.

Ambient air temperature ARIYA_AATConfirmed

  • Service 22DID 4008
  • Module744 → 764
  • Every5 s
  • Testing for 2022, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2022, 2026.

Ambient air temperature, climate module ARIYA_HVAC_AAT

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2022 to 2026.

Blower on ARIYA_HVAC_FAN_ON

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2022 to 2026.

Blower voltage ARIYA_HVAC_BLOWER_V

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 89 to 95 of the reply, 7 bits.

Formula
val
Range
0 to 127 V
Unit
V

In testing for 2022 to 2026.

Cabin temperature ARIYA_HVAC_CABIN_T

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2022 to 2026.

Coolant temperature ARIYA_ECT

  • Service 22DID F467
  • Module744 → 764
  • Every5 s
  • Testing for 2022, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2022, 2026. Supported for 2023 to 2025.

Evaporator temperature ARIYA_HVAC_EVAP_T

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2022 to 2026.

Sun load ARIYA_HVAC_SUNLOAD

  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2026.

Control Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2025.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2025.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2023 to 2025.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2023 to 2025.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023 to 2025.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2023 to 2025.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023 to 2025.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2023.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023 to 2025.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2023.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023 to 2025.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2023.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023 to 2025.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2023.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023 to 2025.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2023.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023 to 2025.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2023.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023 to 2025.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2023.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023 to 2025.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2023.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023 to 2025.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2023.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023 to 2025.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2023.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023 to 2025.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024 to 2025. Supported for 2023.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023 to 2025.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2023 to 2025.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2024 to 2025. Supported for 2023.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Engine

Actual EGR A duty cycle/position EGR_A_ACTSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

Actual EGR B duty cycle/position EGR_B_ACTSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2024 to 2025. Supported for 2023.

Boost pressure sensor A BP_A_ACTSAE J1979Confirmed

Actual turbocharger/supercharger A boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024 to 2025. Supported for 2023.

Boost pressure sensor B BP_B_ACTSAE J1979Confirmed

Actual turbocharger/supercharger B boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024 to 2025. Supported for 2023.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2025.

Commanded boost pressure A BP_A_CMDSAE J1979Confirmed

Turbocharger/supercharger A commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024 to 2025. Supported for 2023.

Commanded boost pressure B BP_B_CMDSAE J1979Confirmed

Turbocharger/supercharger B commanded boost pressure.

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024 to 2025. Supported for 2023.

Commanded EGR A duty cycle/position EGR_A_CMDSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

Commanded EGR B duty cycle/position EGR_B_CMDSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

Commanded Throttle Actuator A Control TAC_A_CMDSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

Commanded Throttle Actuator B Control TAC_B_CMDSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

Commanded wastegate A position WG_A_CMDSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

Commanded wastegate B position WG_B_CMDSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

EGR A error EGR_A_ERRSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

EGR B error EGR_B_ERRSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. Supported for 2023.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024 to 2025. Supported for 2023.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2024 to 2025. Supported for 2023.

Exhaust Gas Recirculation Temp Sensor A (Bank 1, Sensor 1) EGRTASAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. Supported for 2023 to 2024.

Exhaust Gas Recirculation Temp Sensor B (Bank 2, Sensor 1) EGRTBSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. Supported for 2023 to 2024.

Exhaust Gas Recirculation Temp Sensor C (Bank 1, Sensor 2) EGRTCSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. Supported for 2023 to 2024.

Exhaust Gas Recirculation Temp Sensor D (Bank 2, Sensor 2) EGRTDSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. Supported for 2023 to 2024.

Mass Air Flow Sensor A MAFASAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2023 to 2025.

Mass Air Flow Sensor B MAFBSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2023 to 2025.

Relative Throttle A Position TP_A_RELSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

Relative Throttle B Position TP_B_RELSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

Total Engine Run Time RUN_TIMESAE J1979Confirmed

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Confirmed for 2024 to 2025. Supported for 2023.

Total Idle Run Time IDLE_TIMESAE J1979Confirmed

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Confirmed for 2024 to 2025. Supported for 2023.

Total Run Time With PTO Active PTO_TIMESAE J1979Confirmed

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Confirmed for 2024 to 2025. Supported for 2023.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2024 to 2025. Supported for 2023.

Wastegate A position WG_A_ACTSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

Wastegate B position WG_B_ACTSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024 to 2025. Supported for 2023.

AuxInputs

Auto Trans Neutral Drive Status N/D_STATSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Glow plug lamp status GPL_STATSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Manual Trans Neutral Gear Status N/G_STATSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Power Take Off (PTO) Output Status PTO_STAT_AUXSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Recommended gear GEAR_RCMDSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 11 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

AuxInputs › Internal

Auto trans neutral drive status supported N/D_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Glow plug lamp status supported GPL_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Manual trans neutral gear status supported N/G_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Power Take Off (PTO) output status supported PTO_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Recommended gear supported GEAR_SUPSAE J1979Confirmed

  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Internal

Actual EGR A supported EGR_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Actual EGR A supported EGR_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Commanded EGR A supported EGR_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Commanded EGR A supported EGR_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Commanded Throttle Actuator A Control supported? CTAC_A_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Commanded Throttle Actuator B Control supported? CTAC_B_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

EGR A error supported EGR_A_ERR_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

EGR A error supported EGR_B_ERR_SUPSAE J1979Confirmed

  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

EGR Temperature Sensor A (Bank 1, Sensor 1) supported? EGRTA_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023 to 2024.

EGR Temperature Sensor A (Bank 1, Sensor 1) Wide Range supported? EGRTA_WR_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023 to 2024.

EGR Temperature Sensor B (Bank 2, Sensor 1) supported? EGRTB_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023 to 2024.

EGR Temperature Sensor B (Bank 2, Sensor 1) Wide Range supported? EGRTB_WR_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023 to 2024.

EGR Temperature Sensor C (Bank 1, Sensor 2) supported? EGRTC_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023 to 2024.

EGR Temperature Sensor C (Bank 1, Sensor 2) Wide Range supported? EGRTC_WR_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023 to 2024.

EGR Temperature Sensor D (Bank 2, Sensor 2) supported? EGRTD_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023 to 2024.

EGR Temperature Sensor D (Bank 2, Sensor 2) Wide Range supported? EGRTD_WR_SUPSAE J1979Confirmed

  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2023 to 2024.

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2024 to 2025. Supported for 2023.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2024 to 2025. Supported for 2023.

MAF Sensor A supported MAFA_SUPSAE J1979Confirmed

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

MAF Sensor B supported MAFB_SUPSAE J1979Confirmed

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023 to 2025.

Maximum value for air flow rate from mass air flow sensor MAX_MAFSAE J1979Confirmed

  • Service 01PID 50
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 g/s
Unit
g/s

Confirmed for 2024 to 2025. Supported for 2023.

Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2024 to 2025. Supported for 2023.

Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 24 to 31 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 kPa
Unit
kPa

Confirmed for 2024 to 2025. Supported for 2023.

Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

Confirmed for 2024 to 2025. Supported for 2023.

Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed

  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

Confirmed for 2024 to 2025. Supported for 2023.

Relative Throttle A Position data supported? RTP_A_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Relative Throttle B Position data supported? RTP_B_SUPSAE J1979Confirmed

  • Service 01PID 6C
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Total Engine Run Time supported? RUN_TIME_SUPSAE J1979Confirmed

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Total Idle Run Time supported? IDLE_TIME_SUPSAE J1979Confirmed

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Total Run Time With PTO Active supported? PTO_TIME_SUPSAE J1979Confirmed

  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed

  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024 to 2025. Supported for 2023.

Fuel

Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2023, 2025. Supported for 2024.

Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2023, 2025. Supported for 2024.

Fuel Rail Pressure A FRP_ASAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2023, 2025. Supported for 2024.

Fuel Rail Pressure B FRP_BSAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2023, 2025. Supported for 2024.

Fuel Rail Temperature A FRT_ASAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025. Supported for 2024.

Fuel Rail Temperature B FRT_BSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 80 to 87 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025. Supported for 2024.

Fuel system A use percentage bank 1 FUELSYSA_B1SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025. Supported for 2024.

Fuel system A use percentage bank 2 FUELSYSA_B2SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025. Supported for 2024.

Fuel system A use percentage bank 3 FUELSYSA_B3SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025. Supported for 2024.

Fuel system A use percentage bank 4 FUELSYSA_B4SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 63 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025. Supported for 2024.

Fuel system B use percentage bank 1 FUELSYSB_B1SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025. Supported for 2024.

Fuel system B use percentage bank 2 FUELSYSB_B2SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025. Supported for 2024.

Fuel system B use percentage bank 3 FUELSYSB_B3SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025. Supported for 2024.

Fuel system B use percentage bank 4 FUELSYSB_B4SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025. Supported for 2024.

Internal

Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed

  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023, 2025. Supported for 2024.

Movement

Fan speed ARIYA_FAN_SPD

  • Service 22DID 912E
  • ModuleDADB → DAF1DB
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2022 to 2026.

Fan speed ARIYA_FAN_SPD_DADB

  • Service 22DID 91F0
  • ModuleDADB → DAF1DB
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2022 to 2026.

Vehicle speed ARIYA_VSS

Pelican can show this parameter as the speed.

  • Service 22DID 2003
  • ModuleDADA → DAF1DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2022 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2023 to 2025.

Tires

Front left tire pressure ARIYA_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 0E26
  • Module743 → 763
  • Every15 s
  • Testing for 2022, 2026

Example reply from a 2025 Nissan ARIYA.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.7236894
Range
0 to 439.5 kPa
Unit
kPa

0x84 = 132 → 132×1.7236894 = 227.527001 kPa

Confirmed for 2023 to 2025. In testing for 2022, 2026.

Front right tire pressure ARIYA_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 0E25
  • Module743 → 763
  • Every15 s
  • Testing for 2022, 2026

Example reply from a 2025 Nissan ARIYA.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.7236894
Range
0 to 439.5 kPa
Unit
kPa

0x78 = 120 → 120×1.7236894 = 206.842728 kPa

Confirmed for 2023 to 2025. In testing for 2022, 2026.

Rear left tire pressure ARIYA_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 0E28
  • Module743 → 763
  • Every15 s
  • Testing for 2022, 2026

Example reply from a 2025 Nissan ARIYA.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.7236894
Range
0 to 439.5 kPa
Unit
kPa

0x84 = 132 → 132×1.7236894 = 227.527001 kPa

Confirmed for 2023 to 2025. In testing for 2022, 2026.

Rear right tire pressure ARIYA_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 0E27
  • Module743 → 763
  • Every15 s
  • Testing for 2022, 2026

Example reply from a 2025 Nissan ARIYA.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.7236894
Range
0 to 439.5 kPa
Unit
kPa

0x84 = 132 → 132×1.7236894 = 227.527001 kPa

Confirmed for 2023 to 2025. In testing for 2022, 2026.

Trips

Odometer ARIYA_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 0E01
  • Module743 → 763
  • Every30 s
  • Testing for 2022, 2026

Example reply from a 2025 Nissan ARIYA.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x001297 = 4759 → 4,759 km

Confirmed for 2023 to 2025. In testing for 2022, 2026.

Odometer, meter group 1 ARIYA_ODO_METER

Pelican can show this parameter as the odometer.

  • Service 21PID 01
  • Module743 → 763
  • Every30 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2022 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.