Parameters
The Nissan 350Z has 33 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Mass air flow volts, B1 Z350_MAF_VOLTS_B1
- Service 22
DID 1204 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 327 V
- Unit
- V
In testing for 2003 to 2009.
Control
Accelerator pedal position Z350_APP
- Service 22
DID 1115 - Module
740 → 760 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 2003 to 2009.
Anti-lock brake steering angle Z350_ABS_STEER_ANG
- Service 22
DID 1208 - Module
740 → 760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
In testing for 2003 to 2009.
Brake master cylinder pressure count Z350_BRAKE_MC_P
- Service 22
DID 1209 - Module
740 → 760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2003 to 2009.
Brake switch Z350_BRAKE_SWITCH
- Service 22
DID 1305 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2003 to 2009.
Engine
A/F ratio adj, B1 Z350_F_RAT_ADJ_B1
- Service 22
DID 1123 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 155 %
- Unit
- %
In testing for 2003 to 2009.
Air conditioning compressor Z350_AC_COMP
- Service 22
DID 1307 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Camshaft adv angle, B1 Z350_CAM_ADV_ANG_B1
- Service 22
DID 1135 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2003 to 2009.
Camshaft valve duty, B1 Z350_CAM_VLV_DUTY_B1
- Service 22
DID 1138 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2003 to 2009.
Cooling fan high Z350_COOLING_FAN_HIGH
- Service 22
DID 1313 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Cooling fan low Z350_COOLING_FAN_LOW
- Service 22
DID 1313 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
EVAP purge duty Z350_EVAP_PURGE_DUTY
- Service 22
DID 1110 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2003 to 2009.
Idle control mode Z350_IDLE_CTRL_MODE
- Service 22
DID 1307 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Ignition timing advance Z350_IGN_TIM_ADVANCE
- Service 22
DID 110A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -145 to 110 °
- Unit
- °
In testing for 2003 to 2009.
Intake camshaft advance, bank 2 Z350_CAM_ADV_B2
- Service 22
DID 1137 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2003 to 2009.
Intake valve timing solenoid duty, bank 2 Z350_CAM_DUTY_B2
- Service 22
DID 1139 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2003 to 2009.
Mass air flow Z350_MAF
- Service 22
DID 1209 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 g/s
- Unit
- g/s
In testing for 2003 to 2009.
Mass air flow sensor voltage, bank 2 Z350_MAF_V_B2
- Service 22
DID 1205 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 327 V
- Unit
- V
In testing for 2003 to 2009.
Variable valve timing oil temperature Z350_VARIABLE_VLV_TIM_OIL_T
- Service 22
DID 111F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Fuel
Air/fuel ratio adjustment, bank 2 Z350_AF_ADJ_B2
- Service 22
DID 1124 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 155 %
- Unit
- %
In testing for 2003 to 2009.
Fuel base pulse width Z350_FUEL_BASE_WIDTH
- Service 22
DID 1208 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 31.99 ms
- Unit
- ms
In testing for 2003 to 2009.
Fuel temperature Z350_FUEL_T
- Service 22
DID 1111 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Movement
Current engine speed Z350_CURRENT_RPM
- Service 22
DID 1201 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 819187 rpm
- Unit
- rpm
In testing for 2003 to 2009.
Output speed Z350_OUTPUT_SPD
- Service 21
PID 01 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2003 to 2009.
Turbine speed Z350_TURBINE_SPD
- Service 21
PID 01 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2003 to 2009.
Transmission
Torque converter slip Z350_TQ_CONV_SLIP
- Service 21
PID 01 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 120 to 135 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2003 to 2009.
Transmission fluid temperature, variant 1 Z350_ATF_T_VAR_1
- Service 21
PID 01 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
- Range
- -67 to 392 °F
- Unit
- °F
In testing for 2003 to 2009.
Transmission fluid temperature, variant 2 Z350_ATF_T_VAR_2
- Service 21
PID 01 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
- Range
- -67 to 392 °F
- Unit
- °F
In testing for 2003 to 2009.
Transmission work hours Z350_TRANS_WORK_HOURS
- Service 21
PID 10 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 10922 h
- Unit
- h
In testing for 2003 to 2009.
Transmission work hours warm engine Z350_TRANS_WORK_HOURS_WARM_ENG
- Service 21
PID 10 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 10922 h
- Unit
- h
In testing for 2003 to 2009.
Transmission-A Z350_TRANS
- Service 21
PID 10 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2009.
Transmission-B Z350_TRANS_B
- Service 21
PID 10 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2009.
Trips
Odometer, meter group 1 Z350_ODO_METER
Pelican can show this parameter as the odometer.
- Service 21
PID 01 - Module
743 → 763 - Every
30 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2003 to 2009.