Mitsubishi Triton

Parameters

The Mitsubishi Triton has 222 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine coolant temperature TRITON_AC_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery temperature TRITON_BAT_TConfirmed

  • Service 21PID 46
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Engine control module voltage TRITON_ENG_CTRL_MODULE_V

  • Service 22DID 4000
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1832500
Range
0 to 18.66 V
Unit
V

In testing for 2023 to 2026.

Turbocharger, actual position TRITON_TURBOCHARGER_ACT_POS

  • Service 22DID 4506
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2023 to 2026.

Turbocharger, target position TRITON_TURBOCHARGER_TGT_POS

  • Service 22DID 4506
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2023 to 2026.

Climate

A/C compressor drive flag TRITON_AC_A_C_COMPRESSOR_DRIVE_FLAGConfirmed

  • Service 21PID 70
  • Module688 → 511
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

A/C compressor drive request TRITON_AC_A_C_COMPRESSOR_DRIVE_REQUESTConfirmed

  • Service 21PID 23
  • Module688 → 511
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Air conditioning switch TRITON_AC_SWITCHConfirmed

  • Service 21PID 23
  • Module688 → 511
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Air temperature sensor TRITON_AC_AIR_THERMO_SNSConfirmed

  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val4−16
Range
-16 to 47.75 °C
Unit
°C

0x00 = 0 → 04−16 = -16 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Ambient air temperature TRITON_AC_AATConfirmed

  • Service 21PID 11
  • Module688 → 511
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x00 = 0 → 02−40 = -40 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Compressor ON/OFF count TRITON_AC_COMPRESSOR_ON_OFF_COUNTConfirmed

  • Service 21PID 80
  • Module688 → 511
  • Every3600 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 47 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

0x04C015 = 311317 → 311,317

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Compressor work time TRITON_AC_COMPRESSOR_WORK_TIMEConfirmed

  • Service 21PID 81
  • Module688 → 511
  • Every3600 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 128 to 151 of the reply, 24 bits.

Formula
val×5
Range
0 to 83886075
Unit
Number

0x06192C = 399660 → 399660×5 = 1,998,300

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Conditioner work time TRITON_AC_CONDITIONER_WORK_TIMEConfirmed

  • Service 21PID 81
  • Module688 → 511
  • Every3600 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 104 to 127 of the reply, 24 bits.

Formula
val×5
Range
0 to 83886075
Unit
Number

0x14C869 = 1362025 → 1362025×5 = 6,810,125

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Corrected driver temperature setting TRITON_AC_DRIVER_T_CORRConfirmed

  • Service 21PID 34
  • Module688 → 511
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 50 °C
Unit
°C

0x00 = 0 → 02 = 0 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Corrected passenger temperature setting TRITON_AC_PASSENGER_T_CORRConfirmed

  • Service 21PID 34
  • Module688 → 511
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 31 of the reply, 8 bits.

Formula
val2
Range
0 to 50 °C
Unit
°C

0x00 = 0 → 02 = 0 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Driver side output speed TRITON_AC_OUTPUT_VSS_DRConfirmed

  • Service 21PID 22
  • Module688 → 511
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 16
Unit
Number

0x00 = 0 → 02 = 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Driver temperature setting TRITON_AC_DRIVER_TConfirmed

  • Service 21PID 34
  • Module688 → 511
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 50 °C
Unit
°C

0x00 = 0 → 02 = 0 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Engine coolant temperature TRITON_AC_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Engine RPM TRITON_AC_RPMConfirmed

Pelican can show this parameter as the engine speed.

  • Service 21PID 13
  • Module688 → 511
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 7000 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Fan M1 work time TRITON_AC_FAN_M1_WORK_TIMEConfirmed

  • Service 21PID 83
  • Module688 → 511
  • Every3600 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 40 to 63 of the reply, 24 bits.

Formula
val×5
Range
0 to 83886075
Unit
Number

0x06E7F3 = 452595 → 452595×5 = 2,262,975

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Fan M2 work time TRITON_AC_FAN_M2_WORK_TIMEConfirmed

  • Service 21PID 83
  • Module688 → 511
  • Every3600 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 64 to 87 of the reply, 24 bits.

Formula
val×5
Range
0 to 83886075
Unit
Number

0x023BF7 = 146423 → 146423×5 = 732,115

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Idle up request TRITON_AC_IDLE_UP_REQUESTConfirmed

  • Service 21PID 23
  • Module688 → 511
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 rpm
Unit
rpm

0x00 = 0 → 0 rpm

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Interior temperature TRITON_AC_INTERIOR_TConfirmed

  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val4−16
Range
-16 to 47.75 °C
Unit
°C

0x00 = 0 → 04−16 = -16 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Leak indicator TRITON_AC_LEAK_INDICATORConfirmed

  • Service 21PID 32
  • Module688 → 511
  • Every3600 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Leak indicator at 20% TRITON_AC_LEAK_INDICATOR_20Confirmed

  • Service 21PID 32
  • Module688 → 511
  • Every3600 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Max pressure TRITON_AC_MAX_PRESConfirmed

  • Service 21PID 81
  • Module688 → 511
  • Every3600 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 96 to 103 of the reply, 8 bits.

Formula
val×3.3255
Range
0 to 3.3
Unit
Raw value

0x00 = 0 → 0×3.3255 = 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Output mode TRITON_AC_OUTPUT_MODEConfirmed

  • Service 21PID 22
  • Module688 → 511
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 16
Unit
Number

0x00 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Passenger side output speed TRITON_AC_OUTPUT_VSS_ASConfirmed

  • Service 21PID 22
  • Module688 → 511
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val2
Range
0 to 16
Unit
Number

0x00 = 0 → 02 = 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Passenger temperature setting TRITON_AC_PASSENGER_TConfirmed

  • Service 21PID 34
  • Module688 → 511
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val2
Range
0 to 50 °C
Unit
°C

0x00 = 0 → 02 = 0 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Pressure TRITON_AC_PRESConfirmed

  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×3.3255
Range
0 to 3.3
Unit
Raw value

0x00 = 0 → 0×3.3255 = 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Rear defogger ON/OFF count TRITON_AC_REAR_DEFOGGER_ON_OFF_COUNTConfirmed

  • Service 21PID 80
  • Module688 → 511
  • Every3600 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x00A0 = 160 → 160

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Recirculation time TRITON_AC_RECIRCULATION_TIMEConfirmed

  • Service 21PID 81
  • Module688 → 511
  • Every3600 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 176 to 191 of the reply, 16 bits.

Formula
val×5
Range
0 to 327675 min
Unit
min

0x0E67 = 3687 → 3687×5 = 18,435 min

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Solar sensor TRITON_AC_SOLAR_SNSConfirmed

  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×5.5255
Range
0 to 5.5
Unit
Number

0x00 = 0 → 0×5.5255 = 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

System work time TRITON_AC_SYSTEM_WORK_TIMEConfirmed

  • Service 21PID 80
  • Module688 → 511
  • Every3600 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 23 of the reply, 24 bits.

Formula
val×5
Range
0 to 83886075
Unit
Number

0x17E278 = 1565304 → 1565304×5 = 7,826,520

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Vehicle speed TRITON_AC_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 21PID 13
  • Module688 → 511
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 250 km/h
Unit
km/h

0x0000 = 0 → 0 km/h

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2010, 2013, 2015, 2019, 2022 to 2024.

Brake pedal TRITON_CVT_BRAKEConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Brake switch TRITON_MPI_BRAKE_SWITCHConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Normal brake closed status TRITON_MPI_NORMAL_BRAKE_CLOSED_STSConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Drivetrain

External voltage TRITON_AWC_EXT_V

  • Service 21PID 13
  • Module7B6 → 7B7
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 24 to 39 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 V
Unit
V

In testing for 1996 to 2017, 2019 to 2026. Supported for 2018.

Ignition 1 TRITON_AWC_IG1Confirmed

  • Service 21PID 13
  • Module7B6 → 7B7
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Mileage TRITON_AWC_MILEAGEConfirmed

  • Service 21PID 30
  • Module7B6 → 7B7
  • Every30 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 39 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

0x010801 = 67585 → 6758510 = 6,758.5 km

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Module voltage TRITON_AWC_ECU_V

  • Service 21PID 13
  • Module7B6 → 7B7
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 8 to 23 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 V
Unit
V

In testing for 1996 to 2017, 2019 to 2026. Supported for 2018.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2018. Supported for 2010, 2013, 2015, 2019, 2022 to 2024.

Electrical

Dashboard voltage TRITON_DASHBOARD_VConfirmed

  • Service 21PID AF
  • Module6A0 → 514
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x53 = 83 → 8310 = 8.3 V

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Engine

A/C compressor TRITON_AC_COMPRESSORConfirmed

  • Service 21PID 4E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

A/C compressor relay TRITON_MPI_A_C_COMPRESSOR_RELAYConfirmed

  • Service 21PID 1E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Absolute load TRITON_MPI_ABSOLUTE_LOADConfirmed

  • Service 21PID 1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x7C = 124 → 124×100255 = 48.627451 %

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Accelerator pedal closed position learning, main TRITON_APS_CLOSED_LEARNConfirmed

  • Service 21PID 09
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0007629394−2.5
Range
-2.5 to 47.49 V
Unit
V

0xB38F = 45967 → 45967×0.0007629394−2.5 = 32.570035 V

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2018. Supported for 2010, 2013, 2015, 2019, 2022 to 2024.

Air flow sensor voltage TRITON_MPI_AIR_FLOW_SNS_VConfirmed

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

AT position TRITON_POS

  • Service 22DID 1002
  • Module748 → 768
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Battery voltage TRITON_MPI_BATTERY_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×18255
Range
0 to 18 V
Unit
V

0xAF = 175 → 175×18255 = 12.352941 V

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Boost pressure TRITON_BPConfirmed

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×0.19285
Range
0 to 49.17 psi
Unit
psi

0x6C = 108 → 108×0.19285 = 20.8278 psi

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Boost pressure target TRITON_BOOST_P_TARGET

  • Service 22DID 4506
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×33332500
Range
0 to 339 kPa
Unit
kPa

In testing for 2023 to 2026.

Boost pressure, actual TRITON_BOOST_P_ACT

  • Service 22DID 408F
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×33332500
Range
0 to 339 kPa
Unit
kPa

In testing for 2023 to 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2010, 2013, 2015, 2019, 2022 to 2024.

Calculated load TRITON_MPI_CALCULATED_LOADConfirmed

  • Service 21PID 1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Catalyst temperature TRITON_CAT_TConfirmed

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

0x48 = 72 → 72×5−200 = 160 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Cooling fan duty TRITON_COOLING_FAN_DUTYConfirmed

  • Service 21PID A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Crank angle sensor TRITON_MPI_CRANK_ANGLE_SNSConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 31 of the reply, 16 bits.

Formula
val8
Range
0 to 8000 rpm
Unit
rpm

0x0068 = 104 → 1048 = 13 rpm

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Cranking signal TRITON_MPI_CRANKING_SIG_STConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Cycle consumption TRITON_CYCLE_CONSConfirmed

  • Service 21PID 4A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Raw value

0x00 = 0 → 02 = 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Detonation control learned TRITON_MPI_DETONATION_CTRL_LEARNEDConfirmed

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x03 = 3 → 3×100255 = 1.176471 %

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Detonation retard TRITON_MPI_DETONATION_RETARDConfirmed

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×90255
Range
0 to 90
Unit
Number

0x00 = 0 → 0×90255 = 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Diesel particulate filter differential pressure TRITON_DPF_DIFF_P

  • Service 22DID 4500
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−10
Range
-10 to 117 kPa
Unit
kPa

In testing for 2023 to 2026.

Diesel particulate filter differential pressure TRITON_DPF_DIFF_P_7E0Confirmed

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 31 of the reply, 8 bits.

Formula
val2−10
Range
-10 to 117 kPa
Unit
kPa

0x14 = 20 → 202−10 = 0 kPa

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Diesel particulate filter differential pressure 2 TRITON_DPF_DIFF_P_2

  • Service 22DID 452B
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−10
Range
-10 to 117 kPa
Unit
kPa

In testing for 2023 to 2026.

Diesel particulate filter regeneration request mileage TRITON_DPF_REGEN_REQ

  • Service 22DID 454C
  • ModuleDA15 → 15
  • Every30 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 km
Unit
km

In testing for 2023 to 2026.

Diesel particulate filter regeneration total count TRITON_DPF_REGEN_TOT_CNT

  • Service 22DID 454C
  • ModuleDA15 → 15
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 655
Unit
Number

In testing for 2023 to 2026.

Diesel particulate filter soot TRITON_DPF_SOOTConfirmed

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

0x00 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Diesel particulate filter soot accumulation TRITON_DPF_SOOT_ACCUMULATION

  • Service 22DID 454C
  • ModuleDA15 → 15
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 g/L
Unit
g/L

In testing for 2023 to 2026.

Diesel particulate filter soot load, summation method TRITON_DPF_SOOT_SUMConfirmed

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75
Unit
Number

0x02 = 2 → 220 = 0.1

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Diesel particulate filter soot pressure method, g/l TRITON_DPF_SOOT_P_METHOD_G_LConfirmed

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 31 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75
Unit
Number

0x13 = 19 → 1920 = 0.95

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Diesel particulate filter temperature TRITON_DPF_TConfirmed

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

0x33 = 51 → 51×5−200 = 55 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Diesel particulate filter, maximum temperature 1 TRITON_DPF_MAX_T_1Confirmed

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×10−400
Range
-400 to 2150 °C
Unit
°C

0x7D = 125 → 125×10−400 = 850 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Diesel particulate filter, maximum temperature 2 TRITON_DPF_MAX_T_2Confirmed

  • Service 21PID 5B
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×10−400
Range
-400 to 2150 °C
Unit
°C

0x95 = 149 → 149×10−400 = 1,090 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Diesel particulate filter, maximum temperature 3 TRITON_DPF_MAX_T_3Confirmed

  • Service 21PID 28
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×10−400
Range
-400 to 2150 °C
Unit
°C

0x75 = 117 → 117×10−400 = 770 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Diesel particulate filter, maximum temperature 4 TRITON_DPF_MAX_T_4Confirmed

  • Service 21PID 28
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×10−400
Range
-400 to 2150 °C
Unit
°C

0x70 = 112 → 112×10−400 = 720 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Diesel particulate filter, maximum temperature 5 TRITON_DPF_MAX_T_5Confirmed

  • Service 21PID 28
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×10−400
Range
-400 to 2150 °C
Unit
°C

0x70 = 112 → 112×10−400 = 720 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Diesel particulate filter, maximum temperature, previous TRITON_DPF_MAX_T_PREVIOUSConfirmed

  • Service 21PID 28
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×10−400
Range
-400 to 2150 °C
Unit
°C

0x73 = 115 → 115×10−400 = 750 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Electromagnetic oil pump duty TRITON_EM_OIL_PUMP

  • Service 22DID 150F
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Engine control relay TRITON_MPI_ENGINE_CTRL_RELAYConfirmed

  • Service 21PID 1E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Engine coolant temperature TRITON_MPI_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x55 = 85 → 85−40 = 45 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Engine load TRITON_MPI_ENGINE_LOAD

Pelican can show this parameter as the engine load.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 1996 to 2017, 2019 to 2026. Supported for 2018.

Engine oil pressure TRITON_EOP

  • Service 22DID 4093
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

In testing for 2023 to 2026.

Exhaust gas recirculation valve duty TRITON_EGR_VALVE_DUTYConfirmed

  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val2.549719531
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.549719531 = 0 %

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Exhaust gas temperature TRITON_EXH_GAS_TConfirmed

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

0x45 = 69 → 69×5−200 = 145 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Exhaust gas temperature after DPF TRITON_EXH_GAS_T_AFTER_DPFConfirmed

  • Service 21PID 5B
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

0x49 = 73 → 73×5−200 = 165 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Exhaust gas temperature sensor 0 TRITON_EXH_GAS_T_SENS_0

  • Service 22DID 4500
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

In testing for 2023 to 2026.

Exhaust gas temperature sensor 1 TRITON_EXH_GAS_T_SENS_1

  • Service 22DID 4500
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

In testing for 2023 to 2026.

Exhaust gas temperature sensor 2 TRITON_EXH_GAS_T_SENS_2

  • Service 22DID 4500
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

In testing for 2023 to 2026.

Exhaust gas temperature sensor 3 TRITON_EXH_GAS_T_SENS_3

  • Service 22DID 4500
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

In testing for 2023 to 2026.

Exhaust gas temperature sensor 4 TRITON_EXH_GAS_T_SENS_4

  • Service 22DID 4500
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

In testing for 2023 to 2026.

Exhaust thermistor temperature TRITON_NTC_TConfirmed

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×5−200
Range
-200 to 1075 °C
Unit
°C

0x28 = 40 → 40×5−200 = 0 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Front left pressure TRITON_FL_P

  • Service 21PID A1
  • Module773 → 774
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×1379100000
Range
0 to 3.51 bar
Unit
bar

In testing for 2023 to 2026. Not supported for 2018.

Front left temperature TRITON_FL_T

  • Service 21PID A1
  • Module773 → 774
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026. Not supported for 2018.

Front right pressure TRITON_FR_P

  • Service 21PID A5
  • Module773 → 774
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×1379100000
Range
0 to 3.51 bar
Unit
bar

In testing for 2023 to 2026. Not supported for 2018.

Front right temperature TRITON_FR_T

  • Service 21PID A5
  • Module773 → 774
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026. Not supported for 2018.

Fuel injection interval TRITON_EP_P_C_OConfirmed

  • Service 21PID 4B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 ms
Unit
ms

0x06 = 6 → 610 = 0.6 ms

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Fuel injection volume control, cylinder 1 TRITON_O_E_P_C_O_O_P_1Confirmed

  • Service 21PID 43
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

0x00 = 0 → 010 = 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Fuel injection volume control, cylinder 2 TRITON_O_E_P_C_O_O_P_2Confirmed

  • Service 21PID 43
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

0x00 = 0 → 010 = 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Fuel injection volume control, cylinder 3 TRITON_O_E_P_C_O_O_P_3Confirmed

  • Service 21PID 43
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

0x00 = 0 → 010 = 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Fuel quantity correction, cylinder 1 TRITON_FCCB_CORR_1

  • Service 22DID 4503
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100−1.28
Range
-1.28 to 1.26 ms
Unit
ms

In testing for 2023 to 2026.

Fuel quantity correction, cylinder 2 TRITON_FCCB_CORR_2

  • Service 22DID 4503
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val100−1.28
Range
-1.28 to 1.26 ms
Unit
ms

In testing for 2023 to 2026.

Fuel quantity correction, cylinder 3 TRITON_FCCB_CORR_3

  • Service 22DID 4503
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val100−1.28
Range
-1.28 to 1.26 ms
Unit
ms

In testing for 2023 to 2026.

Fuel quantity correction, cylinder 4 TRITON_FCCB_CORR_4

  • Service 22DID 4503
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val100−1.28
Range
-1.28 to 1.26 ms
Unit
ms

In testing for 2023 to 2026.

Idle status TRITON_MPI_IDLE_STSConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Ignition switch TRITON_MPI_IGN_SWITCHConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Injection amount, smoke limit TRITON_INJ_AMOUNT_SMOKE_LIM

  • Service 22DID 4502
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Raw value

In testing for 2023 to 2026.

Injection quantity TRITON_INJECTION_QTYConfirmed

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

0x00 = 0 → 02 = 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Intake air temperature TRITON_MPI_IATConfirmed

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 120 °C
Unit
°C

0x30 = 48 → 48−40 = 8 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Line pressure control solenoid duty TRITON_LINE_P_CTRL_SOLENOID

  • Service 22DID 150F
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Linear solenoid 1 duty TRITON_LINEAR_SOLENOID_1

  • Service 22DID 150F
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Linear solenoid 2 duty TRITON_LINEAR_SOLENOID_2

  • Service 22DID 150F
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Linear solenoid 3 duty TRITON_LINEAR_SOLENOID_3

  • Service 22DID 150F
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Linear solenoid 4 duty TRITON_LINEAR_SOLENOID_4

  • Service 22DID 150F
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Lock-up control solenoid duty TRITON_LOCK_UP_CTRL

  • Service 22DID 150F
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2023 to 2026.

Lock-up solenoid TRITON_LOCK_UP_SOLENOID

  • Service 22DID 150F
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2023 to 2026.

Main accelerator position TRITON_MPI_ACCELERATOR_POSITION_MAINConfirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Main injection timing TRITON_OE_PE_P_CConfirmed

  • Service 21PID 4B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

0x75 = 117 → 117−128 = -11

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Main throttle position TRITON_MPI_THROTTLE_POSITION_MAINConfirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

0x1C = 28 → 28×5255 = 0.54902 V

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Manifold pressure TRITON_MPI_MANIFOLD_PRESConfirmed

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 126 kPa
Unit
kPa

0x3C01 = 15361 → 15361512 = 30.001953 kPa

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Neutral status TRITON_MPI_NEUTRAL_STSConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Off condition TRITON_MPI_OFF_CONDConfirmed

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Oil temperature TRITON_OIL_T

  • Service 22DID 4534
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Particulate filter regeneration TRITON_DPF_REGENConfirmed

  • Service 21PID 59
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Rear left pressure TRITON_RL_P

  • Service 21PID A3
  • Module773 → 774
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×1379100000
Range
0 to 3.51 bar
Unit
bar

In testing for 2023 to 2026. Not supported for 2018.

Rear left temperature TRITON_RL_T

  • Service 21PID A3
  • Module773 → 774
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026. Not supported for 2018.

Rear right pressure TRITON_RR_P

  • Service 21PID A2
  • Module773 → 774
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×1379100000
Range
0 to 3.51 bar
Unit
bar

In testing for 2023 to 2026. Not supported for 2018.

Rear right temperature TRITON_RR_T

  • Service 21PID A2
  • Module773 → 774
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026. Not supported for 2018.

Regeneration request soot deposit TRITON_REGEN_REQ_SOOT

  • Service 22DID 454C
  • ModuleDA15 → 15
  • Every30 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val20
Range
0 to 12.75 g/L
Unit
g/L

In testing for 2023 to 2026.

Small injection quantity learning TRITON_SMALL_INJ_LEARNConfirmed

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 32 to 39 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

0xFF = 255 → 255+1 = 256

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Static engine torque TRITON_STATIC_ENG_TQ

  • Service 22DID 150D
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val2−400
Range
-400 to 32367 N·m
Unit
N·m

In testing for 2023 to 2026.

Sub accelerator position TRITON_MPI_ACCELERATOR_POSITION_SUBConfirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Sub throttle position TRITON_MPI_THROTTLE_POSITION_SUBConfirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

0x00 = 0 → 0×5255 = 0 V

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

T/F status TRITON_T_F_STAT

  • Service 22DID 1106
  • Module748 → 768
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Target idle RPM TRITON_MPI_TGT_IDLE_RPMConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×2000255
Range
0 to 2000 rpm
Unit
rpm

0x41 = 65 → 65×2000255 = 509.803922 rpm

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Target main throttle position TRITON_MPI_TGT_THROTTLE_POSITION_MAINConfirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

0x33 = 51 → 51×5255 = 1 V

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Target throttle control TRITON_MPI_TGT_THROTTLE_CTRLConfirmed

  • Service 21PID 12
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 5 V
Unit
V

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Throttle control relay TRITON_MPI_THROTTLE_CTRL_RELAYConfirmed

  • Service 21PID 1E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Throttle control servo TRITON_MPI_THROTTLE_CTRL_SERVOConfirmed

  • Service 21PID 12
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Throttle pedal sensor TRITON_THROTTLE_PEDAL_SENS

  • Service 22DID 150D
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 %
Unit
%

In testing for 2023 to 2026.

Vehicle speed TRITON_MPI_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×2
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0×2 = 0 km/h

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Fuel

Final fuel injection amount TRITON_FINAL_FUEL_INJ

  • Service 22DID 4502
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Raw value

In testing for 2023 to 2026.

Fuel injection amount at startup TRITON_FUEL_INJ_AMOUNT

  • Service 22DID 4502
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Raw value

In testing for 2023 to 2026.

Fuel injection amount, after TRITON_FUEL_INJ_AMOUNT_AFTER

  • Service 22DID 4507
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 2023 to 2026.

Fuel injection amount, main TRITON_FUEL_INJ_AMOUNT_MAIN

  • Service 22DID 4507
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127
Unit
Raw value

In testing for 2023 to 2026.

Fuel injection amount, pilot TRITON_FUEL_INJ_AMOUNT_PRE

  • Service 22DID 4502
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 2023 to 2026.

Fuel injection amount, pilot 1 TRITON_FUEL_INJ_AMOUNT_1

  • Service 22DID 4501
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 2023 to 2026.

Fuel injection amount, pilot 2 TRITON_FUEL_INJ_AMOUNT_2

  • Service 22DID 4501
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 2023 to 2026.

Fuel injection amount, pilot 3 TRITON_FUEL_INJ_AMOUNT_3

  • Service 22DID 4501
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 2023 to 2026.

Fuel injection amount, post 1 TRITON_FUEL_INJ_AMOUNT_POST_1

  • Service 22DID 4507
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 2023 to 2026.

Fuel injection amount, post 2 TRITON_FUEL_INJ_AMOUNT_POST_2

  • Service 22DID 4507
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 2023 to 2026.

Fuel injection amount, post 3 TRITON_FUEL_INJ_AMOUNT_POST_3

  • Service 22DID 4507
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Raw value

In testing for 2023 to 2026.

Fuel injection duration, main TRITON_FUEL_INJ_DUR_MAIN

  • Service 22DID 4510
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 ms
Unit
ms

In testing for 2023 to 2026.

Fuel injection duration, pilot TRITON_FUEL_INJ_DUR_PRE

  • Service 22DID 4510
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 ms
Unit
ms

In testing for 2023 to 2026.

Fuel level TRITON_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 21PID A3
  • Module6A0 → 514
  • Every30 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−16
Range
0 to 100 %
Unit
%

0x1D = 29 → 29−16 = 13 %

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Fuel meter TRITON_FUEL_METER

  • Service 22DID 0E03
  • Module743 → 763
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×45
Range
0 to 204 L
Unit
L

In testing for 2023 to 2026.

Fuel pressure TRITON_FUEL_P

  • Service 22DID 4522
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2023 to 2026.

Fuel pressure, low TRITON_FUEL_P_LOW

  • Service 22DID 4535
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 kPa
Unit
kPa

In testing for 2023 to 2026.

Fuel pump relay TRITON_MPI_FUEL_PUMP_RELAYConfirmed

  • Service 21PID 1E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Fuel rail pressure TRITON_FUEL_RAIL_PRESConfirmed

  • Service 21PID 4C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×145.04
Range
0 to 36985.2 psi
Unit
psi

0x00 = 0 → 0×145.04 = 0 psi

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Fuel temperature TRITON_FUEL_TConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x36 = 54 → 54−40 = 14 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Fuel temperature TRITON_FUEL_T_DA15

  • Service 22DID 403B
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2023 to 2026.

Target common rail fuel pressure TRITON_TGT_COMMON_RAIL_FUEL_P

  • Service 22DID 4539
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Raw value

In testing for 2023 to 2026.

Movement

Engine speed TRITON_RPM

  • Service 22DID 4002
  • ModuleDA15 → 15
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2023 to 2026.

Engine speed TRITON_RPM_DA18

  • Service 22DID 150D
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 rpm
Unit
rpm

In testing for 2023 to 2026.

Engine speed deviation time 1 TRITON_RPM_DEV_TIME_1

  • Service 22DID 451D
  • ModuleDA15 → 15
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 ms
Unit
ms

In testing for 2023 to 2026.

Engine speed deviation time 2 TRITON_RPM_DEV_TIME_2

  • Service 22DID 451D
  • ModuleDA15 → 15
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 ms
Unit
ms

In testing for 2023 to 2026.

Engine speed deviation time 3 TRITON_RPM_DEV_TIME_3

  • Service 22DID 451E
  • ModuleDA15 → 15
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 ms
Unit
ms

In testing for 2023 to 2026.

Engine speed deviation time 4 TRITON_RPM_DEV_TIME_4

  • Service 22DID 451E
  • ModuleDA15 → 15
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 ms
Unit
ms

In testing for 2023 to 2026.

Input shaft speed TRITON_INPUT_SHFT_SPD

  • Service 22DID 150E
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 rpm
Unit
rpm

In testing for 2023 to 2026.

Output shaft speed TRITON_OUTPUT_SHFT_SPD

  • Service 22DID 150E
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 rpm
Unit
rpm

In testing for 2023 to 2026.

Speed meter TRITON_SPD_METER

  • Service 22DID F40D
  • Module743 → 763
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km/h
Unit
km/h

In testing for 2023 to 2026.

Speed output TRITON_SPD_OUTPUT

  • Service 22DID 0E00
  • Module743 → 763
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2023 to 2026.

Vehicle speed TRITON_VSS

  • Service 22DID 150E
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×145
Range
0 to 714 km/h
Unit
km/h

In testing for 2023 to 2026.

Tires

Spare tire pressure TRITON_SPARE_TIRE_P

  • Service 21PID A4
  • Module773 → 774
  • Every15 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×1379100000
Range
0 to 3.51 bar
Unit
bar

In testing for 2023 to 2026. Not supported for 2018.

Spare tire temperature TRITON_SPARE_TIRE_T

  • Service 21PID A4
  • Module773 → 774
  • Every15 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026. Not supported for 2018.

Tire 1 pressure TRITON_TIRE_1_P

  • Service 21PID A8
  • Module773 → 774
  • Every5 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2023 to 2026. Not supported for 2018.

Tire 1 temperature TRITON_TIRE_1_T

  • Service 21PID A8
  • Module773 → 774
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026. Not supported for 2018.

Tire 2 pressure TRITON_TIRE_2_P

  • Service 21PID A8
  • Module773 → 774
  • Every5 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2023 to 2026. Not supported for 2018.

Tire 2 temperature TRITON_TIRE_2_T

  • Service 21PID A8
  • Module773 → 774
  • Every5 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026. Not supported for 2018.

Tire 3 pressure TRITON_TIRE_3_P

  • Service 21PID A8
  • Module773 → 774
  • Every5 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2023 to 2026. Not supported for 2018.

Tire 3 temperature TRITON_TIRE_3_T

  • Service 21PID A8
  • Module773 → 774
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026. Not supported for 2018.

Tire 4 pressure TRITON_TIRE_4_P

  • Service 21PID A8
  • Module773 → 774
  • Every5 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2023 to 2026. Not supported for 2018.

Tire 4 temperature TRITON_TIRE_4_T

  • Service 21PID A8
  • Module773 → 774
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026. Not supported for 2018.

Wheel speed FL TRITON_WHL_SPD_FL

  • Service 22DID 1013
  • Module748 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×416671000000
Range
0 to 2730 rpm
Unit
rpm

In testing for 2023 to 2026.

Wheel speed FR TRITON_WHL_SPD_FR

  • Service 22DID 1014
  • Module748 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×416671000000
Range
0 to 2730 rpm
Unit
rpm

In testing for 2023 to 2026.

Wheel speed RL TRITON_WHL_SPD_RL

  • Service 22DID 100C
  • Module748 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×416671000000
Range
0 to 2730 rpm
Unit
rpm

In testing for 2023 to 2026.

Wheel speed RR TRITON_WHL_SPD_RR

  • Service 22DID 100D
  • Module748 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×416671000000
Range
0 to 2730 rpm
Unit
rpm

In testing for 2023 to 2026.

Transmission

Accelerator pedal TRITON_CVT_ACCELERATORConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Anti-lock brake actuator signal TRITON_CVT_ABS_ACTUATOR_SIGConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Drive selected TRITON_CVT_SELECTOR_DConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Gear TRITON_GEAR

  • Service 22DID 150E
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Gear number TRITON_CVT_GEAR_AT_NUMBERConfirmed

  • Service 21PID 06
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

Formula
val+1
Range
1 to 256
Unit
Number

0x01 = 1 → 1+1 = 2

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Input speed TRITON_INPUT_VSSConfirmed

  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 23 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

0x0000 = 0 → 02 = 0 rpm

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Lock-up solenoid monitor current TRITON_CVT_LU_SOLENOID_MONITOR_MA

  • Service 21PID 05
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2017, 2019 to 2026.

Lock-up solenoid output current TRITON_CVT_LU_SOLENOID_OUTPUT_MAConfirmed

  • Service 21PID 05
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

0x0000 = 0 → 0 mA

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Lock-up/select changeover solenoid monitor TRITON_CVT_LU_SEL_CHANGEOVER_SOL_MONITOR

  • Service 21PID 05
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bit 115 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2017, 2019 to 2026.

Lock-up/select changeover solenoid output TRITON_CVT_LU_SEL_CHANGEOVER_SOL_OUTPUT

  • Service 21PID 05
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bit 107 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2017, 2019 to 2026.

Low selected TRITON_CVT_SELECTOR_LConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Neutral selected TRITON_CVT_SELECTOR_NConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Output speed TRITON_OUTPUT_VSSConfirmed

  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 39 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 rpm
Unit
rpm

0x0000 = 0 → 02 = 0 rpm

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Paddle shift mode TRITON_CVT_SELECTOR_DS_7E1_06Confirmed

  • Service 21PID 06
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Park selected TRITON_CVT_SELECTOR_PConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Primary pressure TRITON_PRIMARY_PRES_7E1_01Confirmed

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1996 to 2017, 2019 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val×1.332854−85.26
Range
-85.26 to 254 psi
Unit
psi

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Reverse selected TRITON_CVT_SELECTOR_RConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Slip speed TRITON_SLIP_AT_VSS_7E1_02Confirmed

  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 64 to 71 of the reply, 8 bits.

Formula
val−51
Range
-51 to 204 rpm
Unit
rpm

0xFF = 255 → 255−51 = 204 rpm

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Sport mode selected TRITON_CVT_SELECTOR_DSConfirmed

  • Service 21PID 06
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Stability control actuator signal TRITON_CVT_ASC_ACTUATOR_SIGConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Traction control actuator signal TRITON_CVT_TCL_ACTUATOR_SIGConfirmed

  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Transmission fluid temperature TRITON_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x4D = 77 → 77−40 = 37 °C

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Transmission fluid temperature, pan TRITON_ATF_T_PAN

  • Service 22DID 150E
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026.

Transmission fluid temperature, pipe TRITON_ATF_T_PIPE

  • Service 22DID 150E
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026.

Trips

Diesel particulate filter odometer TRITON_DPF_ODOConfirmed

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x017EA2 = 97954 → 97,954 km

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Diesel particulate filter soot accumulation for distance 1 TRITON_DPF_SOOT_1Confirmed

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 km
Unit
km

0x00 = 0 → 0×10 = 0 km

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Distance since last DPF regeneration TRITON_DIST_SINCE_DPF_REGEN

  • Service 22DID 454C
  • ModuleDA15 → 15
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 km
Unit
km

In testing for 2023 to 2026.

Mileage before servicing TRITON_MILEAGE_BEFORE_SERVICINGConfirmed

  • Service 21PID BC
  • Module6A0 → 514
  • Every30 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 km
Unit
km

0xDB = 219 → 219×100 = 21,900 km

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Months before servicing TRITON_PERIOD_BEFORE_SERVICING_MONTHSConfirmed

  • Service 21PID BC
  • Module6A0 → 514
  • Every30 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x06 = 6 → 6

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Odometer TRITON_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 21PID AD
  • Module6A0 → 514
  • Every30 s
  • Testing for 1996 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 16777215 km
Unit
km

0x017E00 = 97792 → 97,792 km

Confirmed for 2018. In testing for 1996 to 2017, 2019 to 2026.

Odometer TRITON_ODO_743

  • Service 22DID 0E01
  • Module743 → 763
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2023 to 2026.

Odometer TRITON_ODO_784

  • Service 21PID 54
  • Module784 → 785
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val×1285
Range
0 to 1677696 km
Unit
km

In testing for 2023 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.