MG ZS EV

Parameters

The MG ZS EV has 189 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Charger connected ZSEV_CHG_CONNECTEDConfirmed

Pelican can show this parameter as the plug state.

  • Service 22DID B71B
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

0b0 = 0 → 0

Confirmed for 2023. In testing for 2019 to 2022.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Charge current limit ZSEV_CHG_A_LIMITConfirmed

  • Service 22DID B712
  • Module7E3 → 7EB
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x03C2 = 962 → 96210 = 96.2 A

Confirmed for 2023. In testing for 2019 to 2022.

Charger connected ZSEV_CHG_CONNECTEDConfirmed

Pelican can show this parameter as the plug state.

  • Service 22DID B71B
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

0b0 = 0 → 0

Confirmed for 2023. In testing for 2019 to 2022.

High voltage battery current ZSEV_HBAT_CConfirmed

  • Service 22DID B043
  • Module781 → 789
  • Every1 s
  • Testing for 2019

Example reply from a 2020 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val40−1000
Range
-1000 to 638.375 mA
Unit
mA

0x8BF7 = 35831 → 3583140−1000 = -104.225 mA

Confirmed for 2020. In testing for 2019. Not supported for 2021 to 2024.

High voltage battery voltage ZSEV_HBAT_VConfirmed

  • Service 22DID B042
  • Module781 → 789
  • Every1 s
  • Testing for 2019

Example reply from a 2020 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
300 to 450 V
Unit
V

0x05D6 = 1494 → 14944 = 373.5 V

Confirmed for 2020. In testing for 2019. Not supported for 2021 to 2024.

Highest cell voltage ZSEV_HVBAT_CELL_V_MAXConfirmed

  • Service 22DID B058
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x0CAB = 3243 → 32431000 = 3.243 V

Confirmed for 2023. In testing for 2019 to 2022.

Highest cell voltage ZSEV_HVBAT_CELL_V_MAX_GEN1

  • Service 22DID B058
  • Module781 → 789
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery coolant temperature ZSEV_HVBAT_COOLANT_TEMPConfirmed

  • Service 22DID B05C
  • Module7E5 → 7ED
  • Every60 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x6C = 108 → 1082−40 = 14 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery coolant temperature ZSEV_HVBAT_COOLANT_TEMP_GEN1Confirmed

  • Service 22DID B05C
  • Module781 → 789
  • Every60 s
  • Testing for 2019

Example reply from a 2020 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x5D = 93 → 932−40 = 6.5 °C

Confirmed for 2020. In testing for 2019. Not supported for 2021, 2023.

HV battery current ZSEV_HVBAT_CURRENTConfirmed

  • Service 22DID B043
  • Module7E5 → 7ED
  • Every250 ms
  • Testing for 2019 to 2021

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.025−1000
Range
0 to 250 A
Unit
A

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery error code ZSEV_HVBAT_ERRConfirmed

  • Service 22DID B047
  • Module7E5 → 7ED
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2023. In testing for 2019 to 2022.

HV battery error code ZSEV_HVBAT_ERR_GEN1

  • Service 22DID B047
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery health ZSEV_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Service 22DID B061
  • Module7E5 → 7ED
  • Every30 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

0x2609 = 9737 → 9737100 = 97.37 %

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery is charging? ZSEV_HVBAT_CHARGINGConfirmed

  • Service 22DID B048
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery main relay B state ZSEV_HVBAT_RELAY_BConfirmed

  • Service 22DID B049
  • Module7E5 → 7ED
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x02 = 2 → 2

Confirmed for 2023. In testing for 2019 to 2022.

HV battery main relay B state ZSEV_HVBAT_RELAY_B_GEN1

  • Service 22DID B049
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery main relay G state ZSEV_HVBAT_RELAY_GConfirmed

  • Service 22DID B04A
  • Module7E5 → 7ED
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2023. In testing for 2019 to 2022.

HV battery main relay G state ZSEV_HVBAT_RELAY_G_GEN1

  • Service 22DID B04A
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery main relay P state ZSEV_HVBAT_RELAY_PConfirmed

  • Service 22DID B052
  • Module7E5 → 7ED
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2023. In testing for 2019 to 2022.

HV battery main relay P state ZSEV_HVBAT_RELAY_P_GEN1

  • Service 22DID B052
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery range count ZSEV_HVBAT_RANGE_RAWConfirmed

  • Service 22DID B0CE
  • Module7E5 → 7ED
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x039E = 926 → 926

Confirmed for 2023 to 2024. In testing for 2019 to 2022.

HV battery range count ZSEV_HVBAT_RANGE_RAW_GEN1

  • Service 22DID B0CE
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery temperature ZSEV_HVBAT_TEMPConfirmed

  • Service 22DID B056
  • Module7E5 → 7ED
  • Every60 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x6F = 111 → 1112−40 = 15.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery temperature ZSEV_HVBAT_TEMP_GEN1Confirmed

  • Service 22DID B056
  • Module781 → 789
  • Every60 s
  • Testing for 2019

Example reply from a 2020 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x5C = 92 → 922−40 = 6 °C

Confirmed for 2020. In testing for 2019. Not supported for 2021, 2023.

HV battery voltage ZSEV_HVBAT_VOLTAGEConfirmed

  • Service 22DID B042
  • Module7E5 → 7ED
  • Every250 ms
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.25
Range
0 to 500 V
Unit
V

0x0545 = 1349 → 1349×0.25 = 337.25 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery voltage, vehicle control unit ZSEV_HVBAT_V_VCUConfirmed

  • Service 22DID B705
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0F3E = 3902 → 390210 = 390.2 V

Confirmed for 2023. In testing for 2019 to 2022.

HV contactor closed ZSEV_HV_CONTACTORConfirmed

  • Service 22DID B703
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

0b1 = 1 → 1

Confirmed for 2023. In testing for 2019 to 2022.

Is charging ZSEV_IS_CHARGINGConfirmed

Pelican can show this parameter as the charging state.

  • Service 22DID B048
  • Module781 → 789
  • Every1 s
  • Testing for 2019, 2021 to 2022

Example reply from a 2020 MG ZS EV.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

0b0 = 0 → 0

Confirmed for 2020. In testing for 2019. Supported for 2023. Not supported for 2021 to 2022, 2024.

Is DC fast charging ZSEV_IS_DCFCConfirmed

  • Service 22DID B048
  • Module781 → 789
  • Every1 s
  • Testing for 2019, 2021 to 2022

Example reply from a 2020 MG ZS EV.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

0b1 = 1 → 1

Confirmed for 2020. In testing for 2019. Supported for 2023. Not supported for 2021 to 2022, 2024.

Lowest cell voltage ZSEV_HVBAT_CELL_V_MINConfirmed

  • Service 22DID B059
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x0CA4 = 3236 → 32361000 = 3.236 V

Confirmed for 2023. In testing for 2019 to 2022.

Lowest cell voltage ZSEV_HVBAT_CELL_V_MIN_GEN1

  • Service 22DID B059
  • Module781 → 789
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

State of charge ZSEV_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID B046
  • Module781 → 789
  • Every1 s
  • Testing for 2019

Example reply from a 2020 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

0x0111 = 273 → 27310 = 27.3 %

Confirmed for 2020. In testing for 2019. Not supported for 2021 to 2024.

State of health ZSEV_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Service 22DID B061
  • Module781 → 789
  • Every1 s
  • Testing for 2019

Example reply from a 2020 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

0x23CD = 9165 → 9165100 = 91.65 %

Confirmed for 2020. In testing for 2019. Not supported for 2021, 2023.

EVCC

Charging ZSEV_EVCC_CHARGING

  • Service 22DID B00F
  • Module7E4 → 7EC
  • Every4 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2025 to 2026. Not supported for 2020 to 2024.

Current ZSEV_EVCC_CURRENT

  • Service 22DID B001
  • Module7E4 → 7EC
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.2−409.6
Range
0 to 250 A
Unit
A

In testing for 2025 to 2026. Not supported for 2020 to 2024.

Max Current ZSEV_EVCC_MAX_CURRENT

  • Service 22DID B003
  • Module7E4 → 7EC
  • Every180 s
  • Testing for 2019 to 2022

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.434782609
Range
0 to 110.869565 A
Unit
A

Supported for 2023. Not supported for 2020 to 2022, 2024.

Voltage ZSEV_EVCC_VOLTAGE

  • Service 22DID B010
  • Module7E4 → 7EC
  • Every4 s
  • Testing for 2019 to 2022

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0103092783
Range
0 to 675.618553 V
Unit
V

Supported for 2023. Not supported for 2020 to 2022, 2024.

Internal

HV battery bus voltage ZSEV_HVBAT_BUS_VOLTAGEConfirmed

  • Service 22DID B041
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1000 V
Unit
V

0x002C = 44 → 444 = 11 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery bus voltage ZSEV_HVBAT_BUS_VOLTAGE_GEN1Confirmed

  • Service 22DID B041
  • Module781 → 789
  • Every1 s
  • Testing for 2019

Example reply from a 2020 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1000 V
Unit
V

0x0006 = 6 → 64 = 1.5 V

Confirmed for 2020. In testing for 2019. Not supported for 2021, 2023.

HV battery internal resistance ZSEV_HVBAT_RESISTANCEConfirmed

  • Service 22DID B045
  • Module7E5 → 7ED
  • Every60 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.5
Range
0 to 32767.5
Unit
Number

0x3FFE = 16382 → 16382×0.5 = 8,191

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 01

HV battery module 01 max temperature ZSEV_HVBAT_CMU01_MAXTEMPConfirmed

  • Service 22DID B001
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7B = 123 → 123×0.5−40 = 21.5 °C

Confirmed for 2023. In testing for 2019 to 2022.

HV battery module 01 max voltage ZSEV_HVBAT_CMU01_MAXVOLTConfirmed

  • Service 22DID B001
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x119F = 4511 → 4511×0.0005+1 = 3.2555 V

Confirmed for 2023. In testing for 2019 to 2022.

HV battery module 01 min temperature ZSEV_HVBAT_CMU01_MINTEMPConfirmed

  • Service 22DID B001
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7B = 123 → 123×0.5−40 = 21.5 °C

Confirmed for 2023. In testing for 2019 to 2022.

HV battery module 01 min voltage ZSEV_HVBAT_CMU01_MINVOLTConfirmed

  • Service 22DID B001
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x1194 = 4500 → 4500×0.0005+1 = 3.25 V

Confirmed for 2023. In testing for 2019 to 2022.

Modules › 02

HV battery module 02 max temperature ZSEV_HVBAT_CMU02_MAXTEMPConfirmed

  • Service 22DID B009
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 02 max voltage ZSEV_HVBAT_CMU02_MAXVOLTConfirmed

  • Service 22DID B009
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BD = 5053 → 5053×0.0005+1 = 3.5265 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 02 min temperature ZSEV_HVBAT_CMU02_MINTEMPConfirmed

  • Service 22DID B009
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 02 min voltage ZSEV_HVBAT_CMU02_MINVOLTConfirmed

  • Service 22DID B009
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13AE = 5038 → 5038×0.0005+1 = 3.519 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 03

HV battery module 03 max temperature ZSEV_HVBAT_CMU03_MAXTEMPConfirmed

  • Service 22DID B011
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7B = 123 → 123×0.5−40 = 21.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 03 max voltage ZSEV_HVBAT_CMU03_MAXVOLTConfirmed

  • Service 22DID B011
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BB = 5051 → 5051×0.0005+1 = 3.5255 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 03 min temperature ZSEV_HVBAT_CMU03_MINTEMPConfirmed

  • Service 22DID B011
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7B = 123 → 123×0.5−40 = 21.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 03 min voltage ZSEV_HVBAT_CMU03_MINVOLTConfirmed

  • Service 22DID B011
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13B5 = 5045 → 5045×0.0005+1 = 3.5225 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 04

HV battery module 04 max temperature ZSEV_HVBAT_CMU04_MAXTEMPConfirmed

  • Service 22DID B019
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 04 max voltage ZSEV_HVBAT_CMU04_MAXVOLTConfirmed

  • Service 22DID B019
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13B8 = 5048 → 5048×0.0005+1 = 3.524 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 04 min temperature ZSEV_HVBAT_CMU04_MINTEMPConfirmed

  • Service 22DID B019
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 04 min voltage ZSEV_HVBAT_CMU04_MINVOLTConfirmed

  • Service 22DID B019
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13A9 = 5033 → 5033×0.0005+1 = 3.5165 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 05

HV battery module 05 max temperature ZSEV_HVBAT_CMU05_MAXTEMPConfirmed

  • Service 22DID B021
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7A = 122 → 122×0.5−40 = 21 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 05 max voltage ZSEV_HVBAT_CMU05_MAXVOLTConfirmed

  • Service 22DID B021
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BC = 5052 → 5052×0.0005+1 = 3.526 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 05 min temperature ZSEV_HVBAT_CMU05_MINTEMPConfirmed

  • Service 22DID B021
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7A = 122 → 122×0.5−40 = 21 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 05 min voltage ZSEV_HVBAT_CMU05_MINVOLTConfirmed

  • Service 22DID B021
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13A6 = 5030 → 5030×0.0005+1 = 3.515 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 06

HV battery module 06 max temperature ZSEV_HVBAT_CMU06_MAXTEMPConfirmed

  • Service 22DID B029
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 06 max voltage ZSEV_HVBAT_CMU06_MAXVOLTConfirmed

  • Service 22DID B029
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13C4 = 5060 → 5060×0.0005+1 = 3.53 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 06 min temperature ZSEV_HVBAT_CMU06_MINTEMPConfirmed

  • Service 22DID B029
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 06 min voltage ZSEV_HVBAT_CMU06_MINVOLTConfirmed

  • Service 22DID B029
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13A8 = 5032 → 5032×0.0005+1 = 3.516 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 07

HV battery module 07 max temperature ZSEV_HVBAT_CMU07_MAXTEMPConfirmed

  • Service 22DID B0A3
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7E = 126 → 126×0.5−40 = 23 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 07 max voltage ZSEV_HVBAT_CMU07_MAXVOLTConfirmed

  • Service 22DID B0A3
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BE = 5054 → 5054×0.0005+1 = 3.527 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 07 min temperature ZSEV_HVBAT_CMU07_MINTEMPConfirmed

  • Service 22DID B0A3
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7E = 126 → 126×0.5−40 = 23 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 07 min voltage ZSEV_HVBAT_CMU07_MINVOLTConfirmed

  • Service 22DID B0A3
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13B5 = 5045 → 5045×0.0005+1 = 3.5225 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 08

HV battery module 08 max temperature ZSEV_HVBAT_CMU08_MAXTEMPConfirmed

  • Service 22DID B0AB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 08 max voltage ZSEV_HVBAT_CMU08_MAXVOLTConfirmed

  • Service 22DID B0AB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BC = 5052 → 5052×0.0005+1 = 3.526 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 08 min temperature ZSEV_HVBAT_CMU08_MINTEMPConfirmed

  • Service 22DID B0AB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 08 min voltage ZSEV_HVBAT_CMU08_MINVOLTConfirmed

  • Service 22DID B0AB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13AA = 5034 → 5034×0.0005+1 = 3.517 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 09

HV battery module 09 max temperature ZSEV_HVBAT_CMU09_MAXTEMPConfirmed

  • Service 22DID B0B3
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7C = 124 → 124×0.5−40 = 22 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 09 max voltage ZSEV_HVBAT_CMU09_MAXVOLTConfirmed

  • Service 22DID B0B3
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BA = 5050 → 5050×0.0005+1 = 3.525 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 09 min temperature ZSEV_HVBAT_CMU09_MINTEMPConfirmed

  • Service 22DID B0B3
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7C = 124 → 124×0.5−40 = 22 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 09 min voltage ZSEV_HVBAT_CMU09_MINVOLTConfirmed

  • Service 22DID B0B3
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13B2 = 5042 → 5042×0.0005+1 = 3.521 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 10

HV battery module 10 max temperature ZSEV_HVBAT_CMU10_MAXTEMPConfirmed

  • Service 22DID B0BB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7E = 126 → 126×0.5−40 = 23 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 10 max voltage ZSEV_HVBAT_CMU10_MAXVOLTConfirmed

  • Service 22DID B0BB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BF = 5055 → 5055×0.0005+1 = 3.5275 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 10 min temperature ZSEV_HVBAT_CMU10_MINTEMPConfirmed

  • Service 22DID B0BB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7E = 126 → 126×0.5−40 = 23 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 10 min voltage ZSEV_HVBAT_CMU10_MINVOLTConfirmed

  • Service 22DID B0BB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13B5 = 5045 → 5045×0.0005+1 = 3.5225 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 11

HV battery module 11 max temperature ZSEV_HVBAT_CMU11_MAXTEMPConfirmed

  • Service 22DID B0C3
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7B = 123 → 123×0.5−40 = 21.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 11 max voltage ZSEV_HVBAT_CMU11_MAXVOLTConfirmed

  • Service 22DID B0C3
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13C9 = 5065 → 5065×0.0005+1 = 3.5325 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 11 min temperature ZSEV_HVBAT_CMU11_MINTEMPConfirmed

  • Service 22DID B0C3
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7B = 123 → 123×0.5−40 = 21.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 11 min voltage ZSEV_HVBAT_CMU11_MINVOLTConfirmed

  • Service 22DID B0C3
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BF = 5055 → 5055×0.0005+1 = 3.5275 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 12

HV battery module 12 max temperature ZSEV_HVBAT_CMU12_MAXTEMPConfirmed

  • Service 22DID B0CB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 12 max voltage ZSEV_HVBAT_CMU12_MAXVOLTConfirmed

  • Service 22DID B0CB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13C7 = 5063 → 5063×0.0005+1 = 3.5315 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 12 min temperature ZSEV_HVBAT_CMU12_MINTEMPConfirmed

  • Service 22DID B0CB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 12 min voltage ZSEV_HVBAT_CMU12_MINVOLTConfirmed

  • Service 22DID B0CB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BC = 5052 → 5052×0.0005+1 = 3.526 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 13

HV battery module 13 max temperature ZSEV_HVBAT_CMU13_MAXTEMPConfirmed

  • Service 22DID B0DB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7E = 126 → 126×0.5−40 = 23 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 13 max voltage ZSEV_HVBAT_CMU13_MAXVOLTConfirmed

  • Service 22DID B0DB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13CA = 5066 → 5066×0.0005+1 = 3.533 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 13 min temperature ZSEV_HVBAT_CMU13_MINTEMPConfirmed

  • Service 22DID B0DB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7E = 126 → 126×0.5−40 = 23 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 13 min voltage ZSEV_HVBAT_CMU13_MINVOLTConfirmed

  • Service 22DID B0DB
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BF = 5055 → 5055×0.0005+1 = 3.5275 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 14

HV battery module 14 max temperature ZSEV_HVBAT_CMU14_MAXTEMPConfirmed

  • Service 22DID B0DC
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 14 max voltage ZSEV_HVBAT_CMU14_MAXVOLTConfirmed

  • Service 22DID B0DC
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13CB = 5067 → 5067×0.0005+1 = 3.5335 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 14 min temperature ZSEV_HVBAT_CMU14_MINTEMPConfirmed

  • Service 22DID B0DC
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 14 min voltage ZSEV_HVBAT_CMU14_MINVOLTConfirmed

  • Service 22DID B0DC
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BE = 5054 → 5054×0.0005+1 = 3.527 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 15

HV battery module 15 max temperature ZSEV_HVBAT_CMU15_MAXTEMPConfirmed

  • Service 22DID B0DD
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x80 = 128 → 128×0.5−40 = 24 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 15 max voltage ZSEV_HVBAT_CMU15_MAXVOLTConfirmed

  • Service 22DID B0DD
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13C2 = 5058 → 5058×0.0005+1 = 3.529 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 15 min temperature ZSEV_HVBAT_CMU15_MINTEMPConfirmed

  • Service 22DID B0DD
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x80 = 128 → 128×0.5−40 = 24 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 15 min voltage ZSEV_HVBAT_CMU15_MINVOLTConfirmed

  • Service 22DID B0DD
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13B8 = 5048 → 5048×0.0005+1 = 3.524 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 16

HV battery module 16 max temperature ZSEV_HVBAT_CMU16_MAXTEMPConfirmed

  • Service 22DID B0DE
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 16 max voltage ZSEV_HVBAT_CMU16_MAXVOLTConfirmed

  • Service 22DID B0DE
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13C7 = 5063 → 5063×0.0005+1 = 3.5315 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 16 min temperature ZSEV_HVBAT_CMU16_MINTEMPConfirmed

  • Service 22DID B0DE
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 16 min voltage ZSEV_HVBAT_CMU16_MINVOLTConfirmed

  • Service 22DID B0DE
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13B1 = 5041 → 5041×0.0005+1 = 3.5205 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 17

HV battery module 17 max temperature ZSEV_HVBAT_CMU17_MAXTEMPConfirmed

  • Service 22DID B10E
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x80 = 128 → 128×0.5−40 = 24 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 17 max voltage ZSEV_HVBAT_CMU17_MAXVOLTConfirmed

  • Service 22DID B10E
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13C3 = 5059 → 5059×0.0005+1 = 3.5295 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 17 min temperature ZSEV_HVBAT_CMU17_MINTEMPConfirmed

  • Service 22DID B10E
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x80 = 128 → 128×0.5−40 = 24 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 17 min voltage ZSEV_HVBAT_CMU17_MINVOLTConfirmed

  • Service 22DID B10E
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13B7 = 5047 → 5047×0.0005+1 = 3.5235 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 18

HV battery module 18 max temperature ZSEV_HVBAT_CMU18_MAXTEMPConfirmed

  • Service 22DID B10F
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x80 = 128 → 128×0.5−40 = 24 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 18 max voltage ZSEV_HVBAT_CMU18_MAXVOLTConfirmed

  • Service 22DID B10F
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13B8 = 5048 → 5048×0.0005+1 = 3.524 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 18 min temperature ZSEV_HVBAT_CMU18_MINTEMPConfirmed

  • Service 22DID B10F
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x80 = 128 → 128×0.5−40 = 24 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 18 min voltage ZSEV_HVBAT_CMU18_MINVOLTConfirmed

  • Service 22DID B10F
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13AF = 5039 → 5039×0.0005+1 = 3.5195 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 19

HV battery module 19 max temperature ZSEV_HVBAT_CMU19_MAXTEMPConfirmed

  • Service 22DID B110
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 19 max voltage ZSEV_HVBAT_CMU19_MAXVOLTConfirmed

  • Service 22DID B110
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BE = 5054 → 5054×0.0005+1 = 3.527 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 19 min temperature ZSEV_HVBAT_CMU19_MINTEMPConfirmed

  • Service 22DID B110
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 19 min voltage ZSEV_HVBAT_CMU19_MINVOLTConfirmed

  • Service 22DID B110
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13AF = 5039 → 5039×0.0005+1 = 3.5195 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 20

HV battery module 20 max temperature ZSEV_HVBAT_CMU20_MAXTEMPConfirmed

  • Service 22DID B111
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 20 max voltage ZSEV_HVBAT_CMU20_MAXVOLTConfirmed

  • Service 22DID B111
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BA = 5050 → 5050×0.0005+1 = 3.525 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 20 min temperature ZSEV_HVBAT_CMU20_MINTEMPConfirmed

  • Service 22DID B111
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 20 min voltage ZSEV_HVBAT_CMU20_MINVOLTConfirmed

  • Service 22DID B111
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13B2 = 5042 → 5042×0.0005+1 = 3.521 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 21

HV battery module 21 max temperature ZSEV_HVBAT_CMU21_MAXTEMPConfirmed

  • Service 22DID B112
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x80 = 128 → 128×0.5−40 = 24 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 21 max voltage ZSEV_HVBAT_CMU21_MAXVOLTConfirmed

  • Service 22DID B112
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BF = 5055 → 5055×0.0005+1 = 3.5275 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 21 min temperature ZSEV_HVBAT_CMU21_MINTEMPConfirmed

  • Service 22DID B112
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x80 = 128 → 128×0.5−40 = 24 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 21 min voltage ZSEV_HVBAT_CMU21_MINVOLTConfirmed

  • Service 22DID B112
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13AF = 5039 → 5039×0.0005+1 = 3.5195 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 22

HV battery module 22 max temperature ZSEV_HVBAT_CMU22_MAXTEMPConfirmed

  • Service 22DID B113
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x80 = 128 → 128×0.5−40 = 24 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 22 max voltage ZSEV_HVBAT_CMU22_MAXVOLTConfirmed

  • Service 22DID B113
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13C0 = 5056 → 5056×0.0005+1 = 3.528 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 22 min temperature ZSEV_HVBAT_CMU22_MINTEMPConfirmed

  • Service 22DID B113
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x80 = 128 → 128×0.5−40 = 24 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 22 min voltage ZSEV_HVBAT_CMU22_MINVOLTConfirmed

  • Service 22DID B113
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13B7 = 5047 → 5047×0.0005+1 = 3.5235 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 23

HV battery module 23 max temperature ZSEV_HVBAT_CMU23_MAXTEMPConfirmed

  • Service 22DID B114
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 23 max voltage ZSEV_HVBAT_CMU23_MAXVOLTConfirmed

  • Service 22DID B114
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13CB = 5067 → 5067×0.0005+1 = 3.5335 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 23 min temperature ZSEV_HVBAT_CMU23_MINTEMPConfirmed

  • Service 22DID B114
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 23 min voltage ZSEV_HVBAT_CMU23_MINVOLTConfirmed

  • Service 22DID B114
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13C2 = 5058 → 5058×0.0005+1 = 3.529 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Modules › 24

HV battery module 24 max temperature ZSEV_HVBAT_CMU24_MAXTEMPConfirmed

  • Service 22DID B115
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 24 max voltage ZSEV_HVBAT_CMU24_MAXVOLTConfirmed

  • Service 22DID B115
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13BA = 5050 → 5050×0.0005+1 = 3.525 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 24 min temperature ZSEV_HVBAT_CMU24_MINTEMPConfirmed

  • Service 22DID B115
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

0x7F = 127 → 127×0.5−40 = 23.5 °C

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

HV battery module 24 min voltage ZSEV_HVBAT_CMU24_MINVOLTConfirmed

  • Service 22DID B115
  • Module7E5 → 7ED
  • Every180 s
  • Testing for 2019 to 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

0x13B1 = 5041 → 5041×0.0005+1 = 3.5205 V

Confirmed for 2022 to 2024. Not supported for 2020 to 2021.

Climate

A/C power ZSEV_AC_PConfirmed

  • Service 22DID BB01
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2023. In testing for 2019 to 2022.

Ambient temperature, climate control ZSEV_AAT_ATCConfirmed

  • Service 22DID E01B
  • Module750 → 758
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x021C = 540 → 54010−40 = 14 °C

Confirmed for 2023. In testing for 2019 to 2022.

Blower speed ZSEV_BLOWERConfirmed

  • Service 22DID E00F
  • Module750 → 758
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2023. In testing for 2019 to 2022.

Cabin heater temperature ZSEV_PTC_TConfirmed

  • Service 22DID E01C
  • Module750 → 758
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x01F4 = 500 → 50010−40 = 10 °C

Confirmed for 2023. In testing for 2019 to 2022.

External temperature ZSEV_AATConfirmed

  • Service 22DID BB05
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019

Example reply from a 2024 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 80 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2020 to 2024. In testing for 2019.

Face vent outlet temperature ZSEV_FACE_OUTLET_TConfirmed

  • Service 22DID E013
  • Module750 → 758
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−30
Range
-30 to 6523.5 °C
Unit
°C

0x01F4 = 500 → 50010−30 = 20 °C

Confirmed for 2023. In testing for 2019 to 2022.

Control

Brake pedal ZSEV_BRAKEConfirmed

  • Service 22DID B120
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 %
Unit
%

0x0000 = 0 → 010 = 0 %

Confirmed for 2023. In testing for 2019 to 2022.

Parking brake applied ZSEV_PARK_BRAKEConfirmed

  • Service 22DID BA40
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

0x01 = 1 → 1

Confirmed for 2023. In testing for 2019 to 2022.

Doors

Door open, bonnet ZSEV_DOOR_BONNET

  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2025 to 2026. Not supported for 2020 to 2024.

Door open, boot ZSEV_DOOR_BOOT

  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2025 to 2026. Not supported for 2020 to 2024.

Door open, driver ZSEV_DOOR_DRIVER

  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2025 to 2026. Not supported for 2020 to 2024.

Door open, LH rear ZSEV_DOOR_LH_REAR

  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2025 to 2026. Not supported for 2020 to 2024.

Door open, passenger ZSEV_DOOR_PASSENGER

  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2025 to 2026. Not supported for 2020 to 2024.

Door open, RH rear ZSEV_DOOR_RH_REAR

  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2025 to 2026. Not supported for 2020 to 2024.

Hood open ZSEV_HOODConfirmed

  • Service 22DID BB06
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

0b0 = 0 → 0

Confirmed for 2023. In testing for 2019 to 2022.

Vehicle unlocked ZSEV_UNLOCKEDConfirmed

  • Service 22DID B013
  • Module745 → 74D
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

0b1 = 1 → 1

Confirmed for 2023. In testing for 2019 to 2022.

Drivetrain

Motor coolant temperature ZSEV_MOTOR_COOLANT_TConfirmed

  • Service 22DID B309
  • Module7E3 → 7EB
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3E = 62 → 62−40 = 22 °C

Confirmed for 2023. In testing for 2019 to 2022.

Motor speed ZSEV_MOTOR_RPMConfirmed

  • Service 22DID B402
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32767
Range
-32767 to 32768 rpm
Unit
rpm

0x7F7E = 32638 → 32638−32767 = -129 rpm

Confirmed for 2023. In testing for 2019 to 2022.

Motor temperature ZSEV_MOTOR_TConfirmed

  • Service 22DID B405
  • Module7E3 → 7EB
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3E = 62 → 62−40 = 22 °C

Confirmed for 2023. In testing for 2019 to 2022.

Motor torque ZSEV_MOTOR_TQConfirmed

  • Service 22DID B401
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32767
Range
-32767 to 32768 N·m
Unit
N·m

0x7EA6 = 32422 → 32422−32767 = -345 N·m

Confirmed for 2023. In testing for 2019 to 2022.

Electrical

12V supply voltage ZSEV_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 0112
  • Module7E3 → 7EB
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x7A = 122 → 12210 = 12.2 V

Confirmed for 2023. In testing for 2019 to 2022.

DC/DC converter input current ZSEV_DCDC_IN_AConfirmed

  • Service 22DID B581
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.7
Range
-3276.7 to 3276.8 A
Unit
A

0x7FFF = 32767 → 3276710−3276.7 = 0 A

Confirmed for 2023. In testing for 2019 to 2022.

DC/DC converter input voltage ZSEV_DCDC_IN_VConfirmed

  • Service 22DID B582
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0F32 = 3890 → 389010 = 389 V

Confirmed for 2023. In testing for 2019 to 2022.

DC/DC converter load ZSEV_DCDC_LOAD

  • Service 22DID B025
  • Module785 → 78D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 %
Unit
%

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

DC/DC converter mode ZSEV_DCDC_MODEConfirmed

  • Service 22DID B580
  • Module7E3 → 7EB
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x02 = 2 → 2

Confirmed for 2023. In testing for 2019 to 2022.

DC/DC converter output current ZSEV_DCDC_OUT_AConfirmed

  • Service 22DID B583
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x00B4 = 180 → 18010 = 18 A

Confirmed for 2023. In testing for 2019 to 2022.

DC/DC converter output voltage ZSEV_DCDC_OUT_VConfirmed

  • Service 22DID B584
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0085 = 133 → 13310 = 13.3 V

Confirmed for 2023. In testing for 2019 to 2022.

DC/DC converter temperature ZSEV_DCDC_T

  • Service 22DID B026
  • Module785 → 78D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 65495 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

DC/DC converter temperature, vehicle control unit ZSEV_DCDC_T_VCUConfirmed

  • Service 22DID B587
  • Module7E3 → 7EB
  • Every10 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3E = 62 → 62−40 = 22 °C

Confirmed for 2023. In testing for 2019 to 2022.

Engine

Ignition state ZSEV_IGNConfirmed

  • Service 22DID B18C
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x02 = 2 → 2

Confirmed for 2023. In testing for 2019 to 2022.

Radiator fan state ZSEV_RAD_FANConfirmed

  • Service 22DID BB91
  • Module7E3 → 7EB
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2023. In testing for 2019 to 2022.

Vehicle gateway status ZSEV_GWM_STATUSConfirmed

  • Service 22DID D001
  • Module710 → 718
  • Every4 s
  • Testing for 2019

Example reply from a 2024 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2020 to 2024. In testing for 2019.

Lights

Headlights on ZSEV_DRLConfirmed

  • Service 22DID D117
  • Module740 → 748
  • Every5 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2023. In testing for 2019 to 2022.

Movement

Vehicle reported speed ZSEV_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID BA00
  • Module7E3 → 7EB
  • Every250 ms
  • Testing for 2019

Example reply from a 2024 MG ZS EV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−200
Range
-200 to 455.35 km/h
Unit
km/h

0x4C1D = 19485 → 19485100−200 = -5.15 km/h

Confirmed for 2020 to 2024. In testing for 2019.

Tires

Front left tire pressure ZSEV_BCM_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Front left tire pressure ZSEV_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID B001
  • Module724 → 72C
  • Every5 s
  • Testing for 2019, 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

0x3A = 58 → 58×4 = 232 kPa

Confirmed for 2020, 2022 to 2024. In testing for 2019. Not supported for 2021.

Front left tire temperature ZSEV_BCM_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Front left tire temperature ZSEV_TT_FLConfirmed

  • Service 22DID B003
  • Module724 → 72C
  • Every5 s
  • Testing for 2019, 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

0x23 = 35 → 352 = 17.5 °C

Confirmed for 2020, 2022 to 2024. In testing for 2019. Not supported for 2021.

Front right tire pressure ZSEV_BCM_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Front right tire pressure ZSEV_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID B001
  • Module724 → 72C
  • Every5 s
  • Testing for 2019, 2021

Example reply from a 2024 MG ZS EV.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

0x3C = 60 → 60×4 = 240 kPa

Confirmed for 2020, 2022 to 2024. In testing for 2019. Not supported for 2021.

Front right tire temperature ZSEV_BCM_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Front right tire temperature ZSEV_TT_FRConfirmed

  • Service 22DID B003
  • Module724 → 72C
  • Every5 s
  • Testing for 2019, 2021

Example reply from a 2024 MG ZS EV.

Bits 8 to 15 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

0x24 = 36 → 362 = 18 °C

Confirmed for 2020, 2022 to 2024. In testing for 2019. Not supported for 2021.

Rear left tire pressure ZSEV_BCM_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Rear left tire pressure ZSEV_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID B001
  • Module724 → 72C
  • Every5 s
  • Testing for 2019, 2021

Example reply from a 2024 MG ZS EV.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

0x3B = 59 → 59×4 = 236 kPa

Confirmed for 2020, 2022 to 2024. In testing for 2019. Not supported for 2021.

Rear left tire temperature ZSEV_BCM_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Rear left tire temperature ZSEV_TT_RLConfirmed

  • Service 22DID B003
  • Module724 → 72C
  • Every5 s
  • Testing for 2019, 2021

Example reply from a 2024 MG ZS EV.

Bits 24 to 31 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

0x23 = 35 → 352 = 17.5 °C

Confirmed for 2020, 2022 to 2024. In testing for 2019. Not supported for 2021.

Rear right tire pressure ZSEV_BCM_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Rear right tire pressure ZSEV_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID B001
  • Module724 → 72C
  • Every5 s
  • Testing for 2019, 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

0x3B = 59 → 59×4 = 236 kPa

Confirmed for 2020, 2022 to 2024. In testing for 2019. Not supported for 2021.

Rear right tire temperature ZSEV_BCM_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Rear right tire temperature ZSEV_TT_RRConfirmed

  • Service 22DID B003
  • Module724 → 72C
  • Every5 s
  • Testing for 2019, 2021

Example reply from a 2024 MG ZS EV.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

0x24 = 36 → 362 = 18 °C

Confirmed for 2020, 2022 to 2024. In testing for 2019. Not supported for 2021.

Transmission

Gear selector code ZSEV_GEAR_RAWConfirmed

  • Service 22DID B900
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x05 = 5 → 5

Confirmed for 2023. In testing for 2019 to 2022.

Trips

Odometer ZSEV_GWM_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B921
  • Module710 → 718
  • Every1 s
  • Testing for 2019

Example reply from a 2024 MG ZS EV.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x000000 = 0 → 0 km

Confirmed for 2020 to 2024. In testing for 2019.

Odometer ZSEV_ODO_V2Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B101
  • Module760 → 768
  • Every1 s
  • Testing for 2019, 2021

Example reply from a 2024 MG ZS EV.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x009666 = 38502 → 38,502 km

Confirmed for 2020, 2022 to 2024. In testing for 2019. Not supported for 2021.

Odometer, body control module ZSEV_BCM_ODOConfirmed

  • Service 22DID E101
  • Module740
  • Every30 s
  • Testing for 2019 to 2022

Example reply from a 2023 MG ZS EV.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x00A93A = 43322 → 43,322 km

Confirmed for 2023. In testing for 2019 to 2022.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.