Parameters
The MG One has 17 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2024.
Knock sensor voltage ONE_KNOCK_SNS_V
- Service 22
DID B140 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2024.
ECU
Vehicle gateway status ONE_GWM_STATUSConfirmed
- Service 22
DID D001 - Module
710 → 718 - Every
4 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 MG One.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Engine
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2024.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Engine oil pressure ONE_EOP
- Service 22
DID B036 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1500.7515 kPa
- Unit
- kPa
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Engine oil temperature ONE_EO_T
- Service 22
DID B034 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfires, cylinder 1 ONE_MISFIRES_C1
- Service 22
DID B143 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfires, cylinder 2 ONE_MISFIRES_C2
- Service 22
DID B144 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfires, cylinder 3 ONE_MISFIRES_C3
- Service 22
DID B145 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Misfires, cylinder 4 ONE_MISFIRES_C4
- Service 22
DID B146 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2024.
Transmission fluid temperature, ECU 10472701 and 11194479 ONE_ATF_T_ECU_10472701_11194479
- Service 22
DID B423 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Transmission fluid temperature, ECU 10513229 ONE_ATF_T_ECU_10513229
- Service 22
DID 1940 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Fuel
Fuel tank level ONE_FUEL_TANK_LEVEL
- Service 22
DID B043 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.
Trips
Odometer ONE_GWM_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID B921 - Module
710 → 718 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 MG One.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x000000 = 0 → 0 km