MG HS

Parameters

The MG HS has 149 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Odometer HS_GWM_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B921
  • Module710 → 718
  • Every1 s
  • Testing for 2018 to 2020, 2022 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x0003FF = 1023 → 1,023 km

Confirmed for 2021, 2025. In testing for 2018 to 2020, 2022 to 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery module B011 raw value HS_BMS_B011_RAWConfirmed

  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0758 = 1880 → 1,880

Confirmed for 2025. In testing for 2018 to 2024, 2026.

Battery module B048 raw value HS_BMS_B048_RAWConfirmed

  • Service 22DID B048
  • Module7DF → 7ED
  • Every1 s
  • Testing for 2018 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x97CC = 38860 → 38,860

Confirmed for 2025. In testing for 2018 to 2024, 2026.

Battery module B056 raw value HS_BMS_B056_RAWConfirmed

  • Service 22DID B056
  • Module7DF → 7ED
  • Every60 s
  • Testing for 2018 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x97D6 = 38870 → 38,870

Confirmed for 2025. In testing for 2018 to 2024, 2026.

Battery module B061 raw value HS_BMS_B061_RAWConfirmed

  • Service 22DID B061
  • Module7DF → 7ED
  • Every30 s
  • Testing for 2018 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x97CC = 38860 → 38,860

Confirmed for 2025. In testing for 2018 to 2024, 2026.

Battery module B110 raw value HS_BMS_B110_RAWConfirmed

  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x9826 = 38950 → 38,950

Confirmed for 2025. In testing for 2018 to 2024, 2026.

Battery module B111 raw value HS_BMS_B111_RAWConfirmed

  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x9830 = 38960 → 38,960

Confirmed for 2025. In testing for 2018 to 2024, 2026.

Battery module B112 raw value HS_BMS_B112_RAWConfirmed

  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x9826 = 38950 → 38,950

Confirmed for 2025. In testing for 2018 to 2024, 2026.

Battery module B113 raw value HS_BMS_B113_RAWConfirmed

  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x9826 = 38950 → 38,950

Confirmed for 2025. In testing for 2018 to 2024, 2026.

Battery module B114 raw value HS_BMS_B114_RAWConfirmed

  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x9830 = 38960 → 38,960

Confirmed for 2025. In testing for 2018 to 2024, 2026.

Battery module B115 raw value HS_BMS_B115_RAWConfirmed

  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x981C = 38940 → 38,940

Confirmed for 2025. In testing for 2018 to 2024, 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2025. Supported for 2021.

High voltage battery current HS_HBAT_C

  • Service 22DID B043
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40−1000
Range
-1000 to 638.375 mA
Unit
mA

In testing for 2018 to 2026.

High voltage battery voltage HS_HBAT_V

  • Service 22DID B042
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
300 to 450 V
Unit
V

In testing for 2018 to 2026.

Highest cell voltage HS_HVBAT_CELL_V_MAX_GEN1

  • Service 22DID B058
  • Module781 → 789
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

HV battery coolant temperature HS_HVBAT_COOLANT_TEMP

  • Service 22DID B05C
  • Module7DF → 7ED
  • Every60 s
  • Testing for 2018 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery coolant temperature HS_HVBAT_COOLANT_TEMP_GEN1

  • Service 22DID B05C
  • Module781 → 789
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery current HS_HVBAT_CURRENT

  • Service 22DID B043
  • Module7DF → 7ED
  • Every250 ms
  • Testing for 2018 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val40−1000
Range
-1000 to 638.375 A
Unit
A

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery error code HS_HVBAT_ERR_GEN1

  • Service 22DID B047
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

HV battery main relay b state HS_HVBAT_RELAY_B_GEN1

  • Service 22DID B049
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

HV battery main relay g state HS_HVBAT_RELAY_G_GEN1

  • Service 22DID B04A
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

HV battery main relay p state HS_HVBAT_RELAY_P_GEN1

  • Service 22DID B052
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

HV battery range count HS_HVBAT_RANGE_RAW_GEN1

  • Service 22DID B0CE
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

HV battery temperature HS_HVBAT_TEMP_GEN1

  • Service 22DID B056
  • Module781 → 789
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2018 to 2026.

HV battery voltage HS_HVBAT_VOLTAGE

  • Service 22DID B042
  • Module7DF → 7ED
  • Every250 ms
  • Testing for 2018 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 500 V
Unit
V

In testing for 2018 to 2024, 2026. Supported for 2025.

Is charging HS_IS_CHARGING

Pelican can show this parameter as the charging state.

  • Service 22DID B048
  • Module781 → 789
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Is DC fast charging HS_IS_DCFC

  • Service 22DID B048
  • Module781 → 789
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

Knock sensor voltage HS_KNOCK_SNS_V

  • Service 22DID B140
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

In testing for 2018 to 2026.

Lowest cell voltage HS_HVBAT_CELL_V_MIN_GEN1

  • Service 22DID B059
  • Module781 → 789
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2018 to 2026.

State of charge HS_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID B046
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

State of health HS_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID B061
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026.

EVCC

Charging HS_EVCC_CHARGING_7E4

  • Service 22DID B00F
  • Module7E4 → 7EC
  • Every4 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2026.

Current HS_EVCC_CURRENT

  • Service 22DID B001
  • Module7E4 → 7EC
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5−409.6
Range
0 to 250 A
Unit
A

In testing for 2018 to 2026.

Max current HS_EVCC_MAX_CURRENT_7E4

  • Service 22DID B003
  • Module7E4 → 7EC
  • Every180 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.434782609
Range
0 to 110.8695 A
Unit
A

In testing for 2018 to 2026.

Voltage HS_EVCC_VOLTAGE_7E4

  • Service 22DID B010
  • Module7E4 → 7EC
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val97
Range
0 to 675.6185 V
Unit
V

In testing for 2018 to 2026.

Internal

HV battery bus voltage HS_HVBAT_BUS_VOLTAGE

  • Service 22DID B041
  • Module7DF → 7ED
  • Every30 s
  • Testing for 2018 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1023.75 V
Unit
V

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery bus voltage HS_HVBAT_BUS_VOLTAGE_GEN1

  • Service 22DID B041
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1000 V
Unit
V

In testing for 2018 to 2026.

HV battery internal resistance HS_HVBAT_RESISTANCE

  • Service 22DID B045
  • Module7DF → 7ED
  • Every60 s
  • Testing for 2018 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 8191.5
Unit
Number

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery raw charge HS_HVBAT_RAW_SOC

HV battery raw charge

  • Service 22DID B046
  • Module7DF → 7ED
  • Every30 s
  • Testing for 2018 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2018 to 2024, 2026. Supported for 2025.

Modules › 02

HV battery module 02 max temperature HS_HVBAT_CMU02_MAXTEMP

  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery module 02 max voltage HS_HVBAT_CMU02_MAXVOLT

  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery module 02 min temperature HS_HVBAT_CMU02_MINTEMP

  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery module 02 min voltage HS_HVBAT_CMU02_MINVOLT

  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Supported for 2025.

Modules › 04

HV battery module 04 max temperature HS_HVBAT_CMU04_MAXTEMP

  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery module 04 max voltage HS_HVBAT_CMU04_MAXVOLT

  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery module 04 min temperature HS_HVBAT_CMU04_MINTEMP

  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery module 04 min voltage HS_HVBAT_CMU04_MINVOLT

  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Supported for 2025.

Modules › 05

HV battery module 05 max temperature HS_HVBAT_CMU05_MAXTEMP

  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery module 05 max voltage HS_HVBAT_CMU05_MAXVOLT

  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery module 05 min temperature HS_HVBAT_CMU05_MINTEMP

  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery module 05 min voltage HS_HVBAT_CMU05_MINVOLT

  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Supported for 2025.

Modules › 06

HV battery module 06 max temperature HS_HVBAT_CMU06_MAXTEMP

  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery module 06 max voltage HS_HVBAT_CMU06_MAXVOLT

  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery module 06 min temperature HS_HVBAT_CMU06_MINTEMP

  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Supported for 2025.

HV battery module 06 min voltage HS_HVBAT_CMU06_MINVOLT

  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2018 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Supported for 2025.

Modules › 07

HV battery module 07 max temperature HS_HVBAT_CMU07_MAXTEMP

  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 07 max voltage HS_HVBAT_CMU07_MAXVOLT

  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 07 min temperature HS_HVBAT_CMU07_MINTEMP

  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 07 min voltage HS_HVBAT_CMU07_MINVOLT

  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

Modules › 08

HV battery module 08 max temperature HS_HVBAT_CMU08_MAXTEMP

  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 08 max voltage HS_HVBAT_CMU08_MAXVOLT

  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 08 min temperature HS_HVBAT_CMU08_MINTEMP

  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 08 min voltage HS_HVBAT_CMU08_MINVOLT

  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

Modules › 09

HV battery module 09 max temperature HS_HVBAT_CMU09_MAXTEMP

  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 09 max voltage HS_HVBAT_CMU09_MAXVOLT

  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 09 min temperature HS_HVBAT_CMU09_MINTEMP

  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 09 min voltage HS_HVBAT_CMU09_MINVOLT

  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

Modules › 10

HV battery module 10 max temperature HS_HVBAT_CMU10_MAXTEMP

  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 10 max voltage HS_HVBAT_CMU10_MAXVOLT

  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 10 min temperature HS_HVBAT_CMU10_MINTEMP

  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 10 min voltage HS_HVBAT_CMU10_MINVOLT

  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

Modules › 11

HV battery module 11 max temperature HS_HVBAT_CMU11_MAXTEMP

  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 11 max voltage HS_HVBAT_CMU11_MAXVOLT

  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 11 min temperature HS_HVBAT_CMU11_MINTEMP

  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 11 min voltage HS_HVBAT_CMU11_MINVOLT

  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

Modules › 12

HV battery module 12 max temperature HS_HVBAT_CMU12_MAXTEMP

  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 12 max voltage HS_HVBAT_CMU12_MAXVOLT

  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 12 min temperature HS_HVBAT_CMU12_MINTEMP

  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 12 min voltage HS_HVBAT_CMU12_MINVOLT

  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

Modules › 13

HV battery module 13 max temperature HS_HVBAT_CMU13_MAXTEMP

  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 13 max voltage HS_HVBAT_CMU13_MAXVOLT

  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 13 min temperature HS_HVBAT_CMU13_MINTEMP

  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 13 min voltage HS_HVBAT_CMU13_MINVOLT

  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

Modules › 14

HV battery module 14 max temperature HS_HVBAT_CMU14_MAXTEMP

  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 14 max voltage HS_HVBAT_CMU14_MAXVOLT

  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 14 min temperature HS_HVBAT_CMU14_MINTEMP

  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 14 min voltage HS_HVBAT_CMU14_MINVOLT

  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

Modules › 15

HV battery module 15 max temperature HS_HVBAT_CMU15_MAXTEMP

  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 15 max voltage HS_HVBAT_CMU15_MAXVOLT

  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 15 min temperature HS_HVBAT_CMU15_MINTEMP

  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 15 min voltage HS_HVBAT_CMU15_MINVOLT

  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

Modules › 16

HV battery module 16 max temperature HS_HVBAT_CMU16_MAXTEMP

  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 16 max voltage HS_HVBAT_CMU16_MAXVOLT

  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 16 min temperature HS_HVBAT_CMU16_MINTEMP

  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 16 min voltage HS_HVBAT_CMU16_MINVOLT

  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

Modules › 17

HV battery module 17 max temperature HS_HVBAT_CMU17_MAXTEMP

  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 17 max voltage HS_HVBAT_CMU17_MAXVOLT

  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 17 min temperature HS_HVBAT_CMU17_MINTEMP

  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 17 min voltage HS_HVBAT_CMU17_MINVOLT

  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

Modules › 18

HV battery module 18 max temperature HS_HVBAT_CMU18_MAXTEMP

  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 18 max voltage HS_HVBAT_CMU18_MAXVOLT

  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 18 min temperature HS_HVBAT_CMU18_MINTEMP

  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2018 to 2024, 2026. Not supported for 2025.

HV battery module 18 min voltage HS_HVBAT_CMU18_MINVOLT

  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2018 to 2024, 2026. Not supported for 2025.

Climate

Ambient temperature, climate control HS_AAT_ATC

  • Service 22DID E01B
  • Module750 → 758
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2018 to 2026.

Blower speed HS_BLOWER

  • Service 22DID E00F
  • Module750 → 758
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Cabin heater temperature HS_PTC_T

  • Service 22DID E01C
  • Module750 → 758
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2018 to 2026.

Face vent outlet temperature HS_FACE_OUTLET_T

  • Service 22DID E013
  • Module750 → 758
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−30
Range
-30 to 6523.5 °C
Unit
°C

In testing for 2018 to 2026.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2021.

Doors

Vehicle unlocked HS_UNLOCKED

  • Service 22DID B013
  • Module745 → 74D
  • Every5 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2018 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2025. Supported for 2021.

ECU

Vehicle gateway status HS_GWM_STATUSConfirmed

  • Service 22DID D001
  • Module710 → 718
  • Every4 s
  • Testing for 2018 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2025. In testing for 2018 to 2024, 2026.

Electrical

DC/DC converter load HS_DCDC_LOAD

  • Service 22DID B025
  • Module785 → 78D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 %
Unit
%

In testing for 2018 to 2026.

DC/DC converter temperature HS_DCDC_T

  • Service 22DID B026
  • Module785 → 78D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 65495 °C
Unit
°C

In testing for 2018 to 2026.

Engine

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2025. Supported for 2021.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2021.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2025. Supported for 2021.

Engine oil pressure HS_EOP

  • Service 22DID B036
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×22910000
Range
0 to 1500.7515 kPa
Unit
kPa

In testing for 2018 to 2026.

Engine oil temperature HS_EO_T

  • Service 22DID B034
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2018 to 2026.

Misfires, cylinder 1 HS_MISFIRES_C1

  • Service 22DID B143
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 2 HS_MISFIRES_C2

  • Service 22DID B144
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 3 HS_MISFIRES_C3

  • Service 22DID B145
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Misfires, cylinder 4 HS_MISFIRES_C4

  • Service 22DID B146
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2025. Supported for 2021.

Transmission fluid temperature, ECU 10472701 and 11194479 HS_ATF_T_ECU_10472701_11194479

  • Service 22DID B423
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2026.

Transmission fluid temperature, ECU 10513229 HS_ATF_T_ECU_10513229

  • Service 22DID 1940
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2026.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2025.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2025.

Fuel

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Fuel tank level HS_FUEL_TANK_LEVELConfirmed

  • Service 22DID B043
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

0x00E1 = 225 → 22510 = 22.5 L

Confirmed for 2025. In testing for 2018 to 2024, 2026.

Lights

Headlights on HS_DRL

  • Service 22DID D117
  • Module740 → 748
  • Every5 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2026.

Movement

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2025. Supported for 2021.

Tires

Front left tire pressure HS_BCM_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2018 to 2026.

Front left tire pressure HS_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID B001
  • Module724 → 72C
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

In testing for 2018 to 2026.

Front left tire temperature HS_BCM_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2018 to 2026.

Front left tire temperature HS_TT_FL

  • Service 22DID B003
  • Module724 → 72C
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

In testing for 2018 to 2026.

Front right tire pressure HS_BCM_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2018 to 2026.

Front right tire pressure HS_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID B001
  • Module724 → 72C
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

In testing for 2018 to 2026.

Front right tire temperature HS_BCM_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2018 to 2026.

Front right tire temperature HS_TT_FR

  • Service 22DID B003
  • Module724 → 72C
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

In testing for 2018 to 2026.

Rear left tire pressure HS_BCM_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2018 to 2026.

Rear left tire pressure HS_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID B001
  • Module724 → 72C
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

In testing for 2018 to 2026.

Rear left tire temperature HS_BCM_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2018 to 2026.

Rear left tire temperature HS_TT_RL

  • Service 22DID B003
  • Module724 → 72C
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

In testing for 2018 to 2026.

Rear right tire pressure HS_BCM_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2018 to 2026.

Rear right tire pressure HS_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID B001
  • Module724 → 72C
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

In testing for 2018 to 2026.

Rear right tire temperature HS_BCM_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2018 to 2026.

Rear right tire temperature HS_TT_RR

  • Service 22DID B003
  • Module724 → 72C
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

In testing for 2018 to 2026.

Trips

Odometer HS_GWM_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B921
  • Module710 → 718
  • Every1 s
  • Testing for 2018 to 2020, 2022 to 2024, 2026

Example reply from a 2025 MG HS.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x0003FF = 1023 → 1,023 km

Confirmed for 2021, 2025. In testing for 2018 to 2020, 2022 to 2024, 2026.

Odometer HS_ODO_V2

Pelican can show this parameter as the odometer.

  • Service 22DID B101
  • Module760 → 768
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2018 to 2026.

Odometer, body control module HS_BCM_ODO

  • Service 22DID E101
  • Module740
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2018 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.