MG Hector

Parameters

The MG Hector has 365 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery module B011 raw value MG_BMS_B011_RAW

  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery module B011 raw value MG_BMS_B011_RAW

  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Battery module B048 raw value MG_BMS_B048_RAW

  • Service 22DID B048
  • Module7DF → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Battery module B056 raw value MG_BMS_B056_RAW

  • Service 22DID B056
  • Module7DF → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Battery module B061 raw value MG_BMS_B061_RAW

  • Service 22DID B061
  • Module7DF → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Battery module B110 raw value MG_BMS_B110_RAW

  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Battery module B111 raw value MG_BMS_B111_RAW

  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Battery module B112 raw value MG_BMS_B112_RAW

  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Battery module B113 raw value MG_BMS_B113_RAW

  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Battery module B114 raw value MG_BMS_B114_RAW

  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Battery module B115 raw value MG_BMS_B115_RAW

  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Charge current limit MG_CHG_A_LIMIT

  • Service 22DID B712
  • Module7E3 → 7EB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Charger connected MG_CHG_CONNECTED

Pelican can show this parameter as the plug state.

  • Service 22DID B71B
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2023.

High voltage battery current MG_HBAT_C

  • Service 22DID B043
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40−1000
Range
-1000 to 638.375 mA
Unit
mA

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

High voltage battery voltage MG_HBAT_V

  • Service 22DID B042
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
300 to 450 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Highest cell voltage MG_HVBAT_CELL_V_MAX

  • Service 22DID B058
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Highest cell voltage MG_HVBAT_CELL_V_MAX_GEN1

  • Service 22DID B058
  • Module781 → 789
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery coolant temperature MG_HVBAT_COOLANT_TEMP

  • Service 22DID B05C
  • Module7DF → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery coolant temperature MG_HVBAT_COOLANT_TEMP_GEN1

  • Service 22DID B05C
  • Module781 → 789
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery coolant temperature MG_HVBAT_COOLANT_TEMP_V2

  • Service 22DID B05C
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery current MG_HVBAT_CURRENT

  • Service 22DID B043
  • Module7DF → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40−1000
Range
0 to 250 A
Unit
A

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery current MG_HVBAT_CURRENT_V2

  • Service 22DID B043
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.025−1000
Range
0 to 250 A
Unit
A

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery error code MG_HVBAT_ERR

  • Service 22DID B047
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery error code MG_HVBAT_ERR_GEN1

  • Service 22DID B047
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery health MG_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID B061
  • Module7DF → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery health MG_HVBAT_SOH_V2

Pelican can show this parameter as the state of health.

  • Service 22DID B061
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery is charging? MG_HVBAT_CHARGING

Pelican can show this parameter as the charging state.

  • Service 22DID B048
  • Module7DF → 7ED
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery is charging? MG_HVBAT_CHARGING_V2

  • Service 22DID B048
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery main relay B state MG_HVBAT_RELAY_B

  • Service 22DID B049
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery main relay b state MG_HVBAT_RELAY_B_GEN1

  • Service 22DID B049
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery main relay G state MG_HVBAT_RELAY_G

  • Service 22DID B04A
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery main relay g state MG_HVBAT_RELAY_G_GEN1

  • Service 22DID B04A
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery main relay P state MG_HVBAT_RELAY_P

  • Service 22DID B052
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery main relay p state MG_HVBAT_RELAY_P_GEN1

  • Service 22DID B052
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery range count MG_HVBAT_RANGE_RAW

  • Service 22DID B0CE
  • Module7E5 → 7ED
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery range count MG_HVBAT_RANGE_RAW_GEN1

  • Service 22DID B0CE
  • Module781 → 789
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery temperature MG_HVBAT_TEMP

  • Service 22DID B056
  • Module7DF → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery temperature MG_HVBAT_TEMP_GEN1

  • Service 22DID B056
  • Module781 → 789
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery temperature MG_HVBAT_TEMP_V2

  • Service 22DID B056
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery voltage MG_HVBAT_VOLTAGE

  • Service 22DID B042
  • Module7DF → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 500 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery voltage MG_HVBAT_VOLTAGE_V2

  • Service 22DID B042
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.25
Range
0 to 500 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery voltage, vehicle control unit MG_HVBAT_V_VCU

  • Service 22DID B705
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV contactor closed MG_HV_CONTACTOR

  • Service 22DID B703
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Is charging MG_IS_CHARGING

Pelican can show this parameter as the charging state.

  • Service 22DID B048
  • Module781 → 789
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Is DC fast charging MG_IS_DCFC

  • Service 22DID B048
  • Module781 → 789
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Knock sensor voltage MG_KNOCK_SNS_V

  • Service 22DID B140
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5255
Range
0 to 5 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Lowest cell voltage MG_HVBAT_CELL_V_MIN

  • Service 22DID B059
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Lowest cell voltage MG_HVBAT_CELL_V_MIN_GEN1

  • Service 22DID B059
  • Module781 → 789
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

State of charge MG_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID B046
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

State of health MG_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID B061
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

EVCC

Charging MG_EVCC_CHARGING

  • Service 22DID B00F
  • Module7DF → 7EC
  • Every4 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Charging MG_EVCC_CHARGING_7E4

  • Service 22DID B00F
  • Module7E4 → 7EC
  • Every4 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Current MG_EVCC_CURRENT

  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5−409.6
Range
0 to 250 A
Unit
A

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Current MG_EVCC_CURRENT_V2

  • Service 22DID B001
  • Module7E4 → 7EC
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5−409.6
Range
0 to 250 A
Unit
A

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Max current MG_EVCC_MAX_CURRENT

  • Service 22DID B003
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.434782609
Range
0 to 110.869565 A
Unit
A

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Max current MG_EVCC_MAX_CURRENT_7E4

  • Service 22DID B003
  • Module7E4 → 7EC
  • Every180 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.434782609
Range
0 to 110.8695 A
Unit
A

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Max Current MG_EVCC_MAX_CURRENT_V2

  • Service 22DID B003
  • Module7E4 → 7EC
  • Every180 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.434782609
Range
0 to 110.869565 A
Unit
A

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Voltage MG_EVCC_VOLTAGE

  • Service 22DID B010
  • Module7DF → 7EC
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val97
Range
0 to 675.618556 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Voltage MG_EVCC_VOLTAGE_7E4

  • Service 22DID B010
  • Module7E4 → 7EC
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val97
Range
0 to 675.6185 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Voltage MG_EVCC_VOLTAGE_V2

  • Service 22DID B010
  • Module7E4 → 7EC
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0103092783
Range
0 to 675.618553 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Internal

BMS Status MG_BMS_STATUS

  • Service 22DID B048
  • Module7DF → 7ED
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery bus voltage MG_HVBAT_BUS_VOLTAGE

  • Service 22DID B041
  • Module7DF → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1000 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery bus voltage MG_HVBAT_BUS_VOLTAGE_GEN1

  • Service 22DID B041
  • Module781 → 789
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1000 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery bus voltage MG_HVBAT_BUS_VOLTAGE_V2

  • Service 22DID B041
  • Module7E5 → 7ED
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 1000 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery internal resistance MG_HVBAT_RESISTANCE

  • Service 22DID B045
  • Module7DF → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery internal resistance MG_HVBAT_RESISTANCE_V2

  • Service 22DID B045
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.5
Range
0 to 32767.5
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery raw charge MG_HVBAT_RAW_SOC

HV battery raw charge

  • Service 22DID B046
  • Module7DF → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 01

HV battery module 01 max temperature MG_HVBAT_CMU01_MAXTEMP

  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 01 max temperature MG_HVBAT_CMU01_MAXTEMP_V2

  • Service 22DID B001
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 01 max voltage MG_HVBAT_CMU01_MAXVOLT

  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 01 max voltage MG_HVBAT_CMU01_MAXVOLT_V2

  • Service 22DID B001
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 01 min temperature MG_HVBAT_CMU01_MINTEMP

  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 01 min temperature MG_HVBAT_CMU01_MINTEMP_V2

  • Service 22DID B001
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 01 min voltage MG_HVBAT_CMU01_MINVOLT

  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 01 min voltage MG_HVBAT_CMU01_MINVOLT_V2

  • Service 22DID B001
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 02

HV battery module 02 max temperature MG_HVBAT_CMU02_MAXTEMP

  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 02 max temperature MG_HVBAT_CMU02_MAXTEMP_V2

  • Service 22DID B009
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 02 max voltage MG_HVBAT_CMU02_MAXVOLT

  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 02 max voltage MG_HVBAT_CMU02_MAXVOLT_V2

  • Service 22DID B009
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 02 min temperature MG_HVBAT_CMU02_MINTEMP

  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 02 min temperature MG_HVBAT_CMU02_MINTEMP_V2

  • Service 22DID B009
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 02 min voltage MG_HVBAT_CMU02_MINVOLT

  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 02 min voltage MG_HVBAT_CMU02_MINVOLT_V2

  • Service 22DID B009
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 03

HV battery module 03 max temperature MG_HVBAT_CMU03_MAXTEMP

  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 03 max temperature MG_HVBAT_CMU03_MAXTEMP_V2

  • Service 22DID B011
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 03 max voltage MG_HVBAT_CMU03_MAXVOLT

  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 03 max voltage MG_HVBAT_CMU03_MAXVOLT_V2

  • Service 22DID B011
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 03 min temperature MG_HVBAT_CMU03_MINTEMP

  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 03 min temperature MG_HVBAT_CMU03_MINTEMP_V2

  • Service 22DID B011
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 03 min voltage MG_HVBAT_CMU03_MINVOLT

  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 03 min voltage MG_HVBAT_CMU03_MINVOLT_V2

  • Service 22DID B011
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 04

HV battery module 04 max temperature MG_HVBAT_CMU04_MAXTEMP

  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 04 max temperature MG_HVBAT_CMU04_MAXTEMP_V2

  • Service 22DID B019
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 04 max voltage MG_HVBAT_CMU04_MAXVOLT

  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 04 max voltage MG_HVBAT_CMU04_MAXVOLT_V2

  • Service 22DID B019
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 04 min temperature MG_HVBAT_CMU04_MINTEMP

  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 04 min temperature MG_HVBAT_CMU04_MINTEMP_V2

  • Service 22DID B019
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 04 min voltage MG_HVBAT_CMU04_MINVOLT

  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 04 min voltage MG_HVBAT_CMU04_MINVOLT_V2

  • Service 22DID B019
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 05

HV battery module 05 max temperature MG_HVBAT_CMU05_MAXTEMP

  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 05 max temperature MG_HVBAT_CMU05_MAXTEMP_V2

  • Service 22DID B021
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 05 max voltage MG_HVBAT_CMU05_MAXVOLT

  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 05 max voltage MG_HVBAT_CMU05_MAXVOLT_V2

  • Service 22DID B021
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 05 min temperature MG_HVBAT_CMU05_MINTEMP

  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 05 min temperature MG_HVBAT_CMU05_MINTEMP_V2

  • Service 22DID B021
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 05 min voltage MG_HVBAT_CMU05_MINVOLT

  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 05 min voltage MG_HVBAT_CMU05_MINVOLT_V2

  • Service 22DID B021
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 06

HV battery module 06 max temperature MG_HVBAT_CMU06_MAXTEMP

  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 06 max temperature MG_HVBAT_CMU06_MAXTEMP_V2

  • Service 22DID B029
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 06 max voltage MG_HVBAT_CMU06_MAXVOLT

  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 06 max voltage MG_HVBAT_CMU06_MAXVOLT_V2

  • Service 22DID B029
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 06 min temperature MG_HVBAT_CMU06_MINTEMP

  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 06 min temperature MG_HVBAT_CMU06_MINTEMP_V2

  • Service 22DID B029
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 06 min voltage MG_HVBAT_CMU06_MINVOLT

  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 06 min voltage MG_HVBAT_CMU06_MINVOLT_V2

  • Service 22DID B029
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 07

HV battery module 07 max temperature MG_HVBAT_CMU07_MAXTEMP

  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 07 max temperature MG_HVBAT_CMU07_MAXTEMP_V2

  • Service 22DID B0A3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 07 max voltage MG_HVBAT_CMU07_MAXVOLT

  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 07 max voltage MG_HVBAT_CMU07_MAXVOLT_V2

  • Service 22DID B0A3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 07 min temperature MG_HVBAT_CMU07_MINTEMP

  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 07 min temperature MG_HVBAT_CMU07_MINTEMP_V2

  • Service 22DID B0A3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 07 min voltage MG_HVBAT_CMU07_MINVOLT

  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 07 min voltage MG_HVBAT_CMU07_MINVOLT_V2

  • Service 22DID B0A3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 08

HV battery module 08 max temperature MG_HVBAT_CMU08_MAXTEMP

  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 08 max temperature MG_HVBAT_CMU08_MAXTEMP_V2

  • Service 22DID B0AB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 08 max voltage MG_HVBAT_CMU08_MAXVOLT

  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 08 max voltage MG_HVBAT_CMU08_MAXVOLT_V2

  • Service 22DID B0AB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 08 min temperature MG_HVBAT_CMU08_MINTEMP

  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 08 min temperature MG_HVBAT_CMU08_MINTEMP_V2

  • Service 22DID B0AB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 08 min voltage MG_HVBAT_CMU08_MINVOLT

  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 08 min voltage MG_HVBAT_CMU08_MINVOLT_V2

  • Service 22DID B0AB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 09

HV battery module 09 max temperature MG_HVBAT_CMU09_MAXTEMP

  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 09 max temperature MG_HVBAT_CMU09_MAXTEMP_V2

  • Service 22DID B0B3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 09 max voltage MG_HVBAT_CMU09_MAXVOLT

  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 09 max voltage MG_HVBAT_CMU09_MAXVOLT_V2

  • Service 22DID B0B3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 09 min temperature MG_HVBAT_CMU09_MINTEMP

  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 09 min temperature MG_HVBAT_CMU09_MINTEMP_V2

  • Service 22DID B0B3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 09 min voltage MG_HVBAT_CMU09_MINVOLT

  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 09 min voltage MG_HVBAT_CMU09_MINVOLT_V2

  • Service 22DID B0B3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 10

HV battery module 10 max temperature MG_HVBAT_CMU10_MAXTEMP

  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 10 max temperature MG_HVBAT_CMU10_MAXTEMP_V2

  • Service 22DID B0BB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 10 max voltage MG_HVBAT_CMU10_MAXVOLT

  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 10 max voltage MG_HVBAT_CMU10_MAXVOLT_V2

  • Service 22DID B0BB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 10 min temperature MG_HVBAT_CMU10_MINTEMP

  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 10 min temperature MG_HVBAT_CMU10_MINTEMP_V2

  • Service 22DID B0BB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 10 min voltage MG_HVBAT_CMU10_MINVOLT

  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 10 min voltage MG_HVBAT_CMU10_MINVOLT_V2

  • Service 22DID B0BB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 11

HV battery module 11 max temperature MG_HVBAT_CMU11_MAXTEMP

  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 11 max temperature MG_HVBAT_CMU11_MAXTEMP_V2

  • Service 22DID B0C3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 11 max voltage MG_HVBAT_CMU11_MAXVOLT

  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 11 max voltage MG_HVBAT_CMU11_MAXVOLT_V2

  • Service 22DID B0C3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 11 min temperature MG_HVBAT_CMU11_MINTEMP

  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 11 min temperature MG_HVBAT_CMU11_MINTEMP_V2

  • Service 22DID B0C3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 11 min voltage MG_HVBAT_CMU11_MINVOLT

  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 11 min voltage MG_HVBAT_CMU11_MINVOLT_V2

  • Service 22DID B0C3
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 12

HV battery module 12 max temperature MG_HVBAT_CMU12_MAXTEMP

  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 12 max temperature MG_HVBAT_CMU12_MAXTEMP_V2

  • Service 22DID B0CB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 12 max voltage MG_HVBAT_CMU12_MAXVOLT

  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 12 max voltage MG_HVBAT_CMU12_MAXVOLT_V2

  • Service 22DID B0CB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 12 min temperature MG_HVBAT_CMU12_MINTEMP

  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 12 min temperature MG_HVBAT_CMU12_MINTEMP_V2

  • Service 22DID B0CB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 12 min voltage MG_HVBAT_CMU12_MINVOLT

  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 12 min voltage MG_HVBAT_CMU12_MINVOLT_V2

  • Service 22DID B0CB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 13

HV battery module 13 max temperature MG_HVBAT_CMU13_MAXTEMP

  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 13 max temperature MG_HVBAT_CMU13_MAXTEMP_V2

  • Service 22DID B0DB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 13 max voltage MG_HVBAT_CMU13_MAXVOLT

  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 13 max voltage MG_HVBAT_CMU13_MAXVOLT_V2

  • Service 22DID B0DB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 13 min temperature MG_HVBAT_CMU13_MINTEMP

  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 13 min temperature MG_HVBAT_CMU13_MINTEMP_V2

  • Service 22DID B0DB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 13 min voltage MG_HVBAT_CMU13_MINVOLT

  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 13 min voltage MG_HVBAT_CMU13_MINVOLT_V2

  • Service 22DID B0DB
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 14

HV battery module 14 max temperature MG_HVBAT_CMU14_MAXTEMP

  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 14 max temperature MG_HVBAT_CMU14_MAXTEMP_V2

  • Service 22DID B0DC
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 14 max voltage MG_HVBAT_CMU14_MAXVOLT

  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 14 max voltage MG_HVBAT_CMU14_MAXVOLT_V2

  • Service 22DID B0DC
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 14 min temperature MG_HVBAT_CMU14_MINTEMP

  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 14 min temperature MG_HVBAT_CMU14_MINTEMP_V2

  • Service 22DID B0DC
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 14 min voltage MG_HVBAT_CMU14_MINVOLT

  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 14 min voltage MG_HVBAT_CMU14_MINVOLT_V2

  • Service 22DID B0DC
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 15

HV battery module 15 max temperature MG_HVBAT_CMU15_MAXTEMP

  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 15 max temperature MG_HVBAT_CMU15_MAXTEMP_V2

  • Service 22DID B0DD
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 15 max voltage MG_HVBAT_CMU15_MAXVOLT

  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 15 max voltage MG_HVBAT_CMU15_MAXVOLT_V2

  • Service 22DID B0DD
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 15 min temperature MG_HVBAT_CMU15_MINTEMP

  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 15 min temperature MG_HVBAT_CMU15_MINTEMP_V2

  • Service 22DID B0DD
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 15 min voltage MG_HVBAT_CMU15_MINVOLT

  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 15 min voltage MG_HVBAT_CMU15_MINVOLT_V2

  • Service 22DID B0DD
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 16

HV battery module 16 max temperature MG_HVBAT_CMU16_MAXTEMP

  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 16 max temperature MG_HVBAT_CMU16_MAXTEMP_V2

  • Service 22DID B0DE
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 16 max voltage MG_HVBAT_CMU16_MAXVOLT

  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 16 max voltage MG_HVBAT_CMU16_MAXVOLT_V2

  • Service 22DID B0DE
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 16 min temperature MG_HVBAT_CMU16_MINTEMP

  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 16 min temperature MG_HVBAT_CMU16_MINTEMP_V2

  • Service 22DID B0DE
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 16 min voltage MG_HVBAT_CMU16_MINVOLT

  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 16 min voltage MG_HVBAT_CMU16_MINVOLT_V2

  • Service 22DID B0DE
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 17

HV battery module 17 max temperature MG_HVBAT_CMU17_MAXTEMP

  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 17 max temperature MG_HVBAT_CMU17_MAXTEMP_V2

  • Service 22DID B10E
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 17 max voltage MG_HVBAT_CMU17_MAXVOLT

  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 17 max voltage MG_HVBAT_CMU17_MAXVOLT_V2

  • Service 22DID B10E
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 17 min temperature MG_HVBAT_CMU17_MINTEMP

  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 17 min temperature MG_HVBAT_CMU17_MINTEMP_V2

  • Service 22DID B10E
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 17 min voltage MG_HVBAT_CMU17_MINVOLT

  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 17 min voltage MG_HVBAT_CMU17_MINVOLT_V2

  • Service 22DID B10E
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 18

HV battery module 18 max temperature MG_HVBAT_CMU18_MAXTEMP

  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 18 max temperature MG_HVBAT_CMU18_MAXTEMP_V2

  • Service 22DID B10F
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 18 max voltage MG_HVBAT_CMU18_MAXVOLT

  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 18 max voltage MG_HVBAT_CMU18_MAXVOLT_V2

  • Service 22DID B10F
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 18 min temperature MG_HVBAT_CMU18_MINTEMP

  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 18 min temperature MG_HVBAT_CMU18_MINTEMP_V2

  • Service 22DID B10F
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 18 min voltage MG_HVBAT_CMU18_MINVOLT

  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 18 min voltage MG_HVBAT_CMU18_MINVOLT_V2

  • Service 22DID B10F
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 19

HV battery module 19 max temperature MG_HVBAT_CMU19_MAXTEMP

  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 19 max temperature MG_HVBAT_CMU19_MAXTEMP_V2

  • Service 22DID B110
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 19 max voltage MG_HVBAT_CMU19_MAXVOLT

  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 19 max voltage MG_HVBAT_CMU19_MAXVOLT_V2

  • Service 22DID B110
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 19 min temperature MG_HVBAT_CMU19_MINTEMP

  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 19 min temperature MG_HVBAT_CMU19_MINTEMP_V2

  • Service 22DID B110
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 19 min voltage MG_HVBAT_CMU19_MINVOLT

  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 19 min voltage MG_HVBAT_CMU19_MINVOLT_V2

  • Service 22DID B110
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 20

HV battery module 20 max temperature MG_HVBAT_CMU20_MAXTEMP

  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 20 max temperature MG_HVBAT_CMU20_MAXTEMP_V2

  • Service 22DID B111
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 20 max voltage MG_HVBAT_CMU20_MAXVOLT

  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 20 max voltage MG_HVBAT_CMU20_MAXVOLT_V2

  • Service 22DID B111
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 20 min temperature MG_HVBAT_CMU20_MINTEMP

  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 20 min temperature MG_HVBAT_CMU20_MINTEMP_V2

  • Service 22DID B111
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 20 min voltage MG_HVBAT_CMU20_MINVOLT

  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 20 min voltage MG_HVBAT_CMU20_MINVOLT_V2

  • Service 22DID B111
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 21

HV battery module 21 max temperature MG_HVBAT_CMU21_MAXTEMP

  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 21 max temperature MG_HVBAT_CMU21_MAXTEMP_V2

  • Service 22DID B112
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 21 max voltage MG_HVBAT_CMU21_MAXVOLT

  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 21 max voltage MG_HVBAT_CMU21_MAXVOLT_V2

  • Service 22DID B112
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 21 min temperature MG_HVBAT_CMU21_MINTEMP

  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 21 min temperature MG_HVBAT_CMU21_MINTEMP_V2

  • Service 22DID B112
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 21 min voltage MG_HVBAT_CMU21_MINVOLT

  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 21 min voltage MG_HVBAT_CMU21_MINVOLT_V2

  • Service 22DID B112
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 22

HV battery module 22 max temperature MG_HVBAT_CMU22_MAXTEMP

  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 22 max temperature MG_HVBAT_CMU22_MAXTEMP_V2

  • Service 22DID B113
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 22 max voltage MG_HVBAT_CMU22_MAXVOLT

  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 22 max voltage MG_HVBAT_CMU22_MAXVOLT_V2

  • Service 22DID B113
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 22 min temperature MG_HVBAT_CMU22_MINTEMP

  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 22 min temperature MG_HVBAT_CMU22_MINTEMP_V2

  • Service 22DID B113
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 22 min voltage MG_HVBAT_CMU22_MINVOLT

  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 22 min voltage MG_HVBAT_CMU22_MINVOLT_V2

  • Service 22DID B113
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 23

HV battery module 23 max temperature MG_HVBAT_CMU23_MAXTEMP

  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 23 max temperature MG_HVBAT_CMU23_MAXTEMP_V2

  • Service 22DID B114
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 23 max voltage MG_HVBAT_CMU23_MAXVOLT

  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 23 max voltage MG_HVBAT_CMU23_MAXVOLT_V2

  • Service 22DID B114
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 23 min temperature MG_HVBAT_CMU23_MINTEMP

  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 23 min temperature MG_HVBAT_CMU23_MINTEMP_V2

  • Service 22DID B114
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 23 min voltage MG_HVBAT_CMU23_MINVOLT

  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 23 min voltage MG_HVBAT_CMU23_MINVOLT_V2

  • Service 22DID B114
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Modules › 24

HV battery module 24 max temperature MG_HVBAT_CMU24_MAXTEMP

  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 24 max temperature MG_HVBAT_CMU24_MAXTEMP_V2

  • Service 22DID B115
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 24 max voltage MG_HVBAT_CMU24_MAXVOLT

  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 24 max voltage MG_HVBAT_CMU24_MAXVOLT_V2

  • Service 22DID B115
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 24 min temperature MG_HVBAT_CMU24_MINTEMP

  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
0 to 87.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 24 min temperature MG_HVBAT_CMU24_MINTEMP_V2

  • Service 22DID B115
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.5−40
Range
0 to 150 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 24 min voltage MG_HVBAT_CMU24_MINVOLT

  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2000+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

HV battery module 24 min voltage MG_HVBAT_CMU24_MINVOLT_V2

  • Service 22DID B115
  • Module7E5 → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0005+1
Range
0 to 10 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Climate

A/C power MG_AC_P

  • Service 22DID BB01
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023.

Ambient temperature, climate control MG_AAT_ATC

  • Service 22DID E01B
  • Module750 → 758
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Blower speed MG_BLOWER

  • Service 22DID E00F
  • Module750 → 758
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Cabin heater temperature MG_PTC_T

  • Service 22DID E01C
  • Module750 → 758
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

External temperature MG_AAT

  • Service 22DID BB05
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 80 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Face vent outlet temperature MG_FACE_OUTLET_T

  • Service 22DID E013
  • Module750 → 758
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−30
Range
-30 to 6523.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2023.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023.

Brake pedal MG_BRAKE

  • Service 22DID B120
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 %
Unit
%

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Parking brake applied MG_PARK_BRAKE

  • Service 22DID BA40
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Doors

Door open, bonnet MG_DOOR_BONNET

  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Door open, boot MG_DOOR_BOOT

  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Door open, driver MG_DOOR_DRIVER

  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Door open, LH rear MG_DOOR_LH_REAR

  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Door open, passenger MG_DOOR_PASSENGER

  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Door open, RH rear MG_DOOR_RH_REAR

  • Service 22DID D112
  • Module7E3
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Hood open MG_HOOD

  • Service 22DID BB06
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Vehicle unlocked MG_UNLOCKED

  • Service 22DID B013
  • Module745 → 74D
  • Every5 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Drivetrain

Motor coolant temperature MG_MOTOR_COOLANT_T

  • Service 22DID B309
  • Module7E3 → 7EB
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Motor speed MG_MOTOR_RPM

  • Service 22DID B402
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32767
Range
-32767 to 32768 rpm
Unit
rpm

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Motor temperature MG_MOTOR_T

  • Service 22DID B405
  • Module7E3 → 7EB
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Motor torque MG_MOTOR_TQ

  • Service 22DID B401
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−32767
Range
-32767 to 32768 N·m
Unit
N·m

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2023.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2023.

Support

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2023.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

ECU

Vehicle gateway status MG_GWM_STATUS

  • Service 22DID D001
  • Module710 → 718
  • Every4 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Electrical

12V supply voltage MG_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 0112
  • Module7E3 → 7EB
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

DC/DC converter input current MG_DCDC_IN_A

  • Service 22DID B581
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−3276.7
Range
-3276.7 to 3276.8 A
Unit
A

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

DC/DC converter input voltage MG_DCDC_IN_V

  • Service 22DID B582
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

DC/DC converter load MG_DCDC_LOAD

  • Service 22DID B025
  • Module785 → 78D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 %
Unit
%

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

DC/DC converter mode MG_DCDC_MODE

  • Service 22DID B580
  • Module7E3 → 7EB
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

DC/DC converter output current MG_DCDC_OUT_A

  • Service 22DID B583
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

DC/DC converter output voltage MG_DCDC_OUT_V

  • Service 22DID B584
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

DC/DC converter temperature MG_DCDC_T

  • Service 22DID B026
  • Module785 → 78D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 65495 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

DC/DC converter temperature, vehicle control unit MG_DCDC_T_VCU

  • Service 22DID B587
  • Module7E3 → 7EB
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Engine

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2023.

Ambient temperature, raw count MG_AAT_RAW_CNT

  • Service 22DID E01B
  • Module750 → 758
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023.

DC-DC converter low-voltage current MG_DCDC_LV_CURRENT

  • Service 22DID B022
  • Module785
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 A
Unit
A

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

DC-DC converter power load MG_DCDC_POWER_LOAD

  • Service 22DID B025
  • Module785 → 78D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 A
Unit
A

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023.

Engine oil pressure MG_EOP

  • Service 22DID B036
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×22910000
Range
0 to 1500.7515 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Engine oil temperature MG_EO_T

  • Service 22DID B034
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2023.

FL face outlet temperature MG_FL_FACE_OUTLET_T

  • Service 22DID E013
  • Module750 → 758
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Ignition state MG_IGN

  • Service 22DID B18C
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Misfires, cylinder 1 MG_MISFIRES_C1

  • Service 22DID B143
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Misfires, cylinder 2 MG_MISFIRES_C2

  • Service 22DID B144
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Misfires, cylinder 3 MG_MISFIRES_C3

  • Service 22DID B145
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Misfires, cylinder 4 MG_MISFIRES_C4

  • Service 22DID B146
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Radiator fan state MG_RAD_FAN

  • Service 22DID BB91
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2023.

Transmission fluid temperature, ECU 10472701 and 11194479 MG_ATF_T_ECU_10472701_11194479

  • Service 22DID B423
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Transmission fluid temperature, ECU 10513229 MG_ATF_T_ECU_10513229

  • Service 22DID 1940
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2023.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Confirmed for 2023.

Fuel

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023.

Fuel tank level MG_FUEL_TANK_LEVEL

  • Service 22DID B043
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Lights

Headlights on MG_DRL

  • Service 22DID D117
  • Module740 → 748
  • Every5 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Movement

Blower speed MG_BLOWER_SPD

  • Service 22DID E00F
  • Module750 → 758
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Vehicle reported speed MG_VSS

Pelican can show this parameter as the speed.

  • Service 22DID BA00
  • Module7E3 → 7EB
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−200
Range
-200 to 455.35 km/h
Unit
km/h

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2023.

Tires

Front left tire pressure MG_BCM_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Front left tire pressure MG_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID B001
  • Module724 → 72C
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 300 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Front left tire temperature MG_BCM_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Front left tire temperature MG_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID B003
  • Module724 → 72C
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Front right tire pressure MG_BCM_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Front right tire pressure MG_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID B001
  • Module724 → 72C
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×4
Range
0 to 300 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Front right tire temperature MG_BCM_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Front right tire temperature MG_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID B003
  • Module724 → 72C
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Rear left tire pressure MG_BCM_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Rear left tire pressure MG_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID B001
  • Module724 → 72C
  • Every15 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×4
Range
0 to 300 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Rear left tire temperature MG_BCM_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Rear left tire temperature MG_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID B003
  • Module724 → 72C
  • Every15 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Rear right tire pressure MG_BCM_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Rear right tire pressure MG_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID B001
  • Module724 → 72C
  • Every15 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×4
Range
0 to 300 kPa
Unit
kPa

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Rear right tire temperature MG_BCM_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID E209
  • Module740
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Rear right tire temperature MG_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID B003
  • Module724 → 72C
  • Every15 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Transmission

Gear selector code MG_GEAR_RAW

  • Service 22DID B900
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Trips

Odometer MG_GWM_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID B921
  • Module710 → 718
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Odometer MG_ODO_V2

Pelican can show this parameter as the odometer.

  • Service 22DID B101
  • Module760 → 768
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Odometer reading, raw count MG_ODO_READING_RAW_CNT

  • Service 22DID B101
  • Module760 → 768
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215
Unit
Number

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Odometer, body control module MG_BCM_ODO

  • Service 22DID E101
  • Module740
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.