Parameters
The MG EHS has 149 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
HV battery coolant temperature EHS_HVBAT_COOLANT_TEMPConfirmed
- Service 22
DID B05C - Module
7DF → 7ED - Every
60 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x6C = 108 → = 14 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery current EHS_HVBAT_CURRENTConfirmed
- Service 22
DID B043 - Module
7DF → 7ED - Every
250 ms - Testing for 2020 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 250 A
- Unit
- A
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery health EHS_HVBAT_SOHConfirmed
Pelican can show this parameter as the state of health.
- Service 22
DID B061 - Module
7DF → 7ED - Every
30 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x2561 = 9569 → = 95.69 %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery is charging? EHS_HVBAT_CHARGINGConfirmed
Pelican can show this parameter as the charging state.
- Service 22
DID B048 - Module
7DF → 7ED - Every
1 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
0b1 = 1 → 1
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery temperature EHS_HVBAT_TEMPConfirmed
- Service 22
DID B056 - Module
7DF → 7ED - Every
60 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x70 = 112 → = 16 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery voltage EHS_HVBAT_VOLTAGEConfirmed
- Service 22
DID B042 - Module
7DF → 7ED - Every
250 ms - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 500 V
- Unit
- V
0x04E1 = 1249 → = 312.25 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Knock sensor voltage EHS_KNOCK_SNS_V
- Service 22
DID B140 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
EVCC
Charging EHS_EVCC_CHARGING
- Service 22
DID B00F - Module
7DF → 7EC - Every
4 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Current EHS_EVCC_CURRENT
- Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 250 A
- Unit
- A
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Max current EHS_EVCC_MAX_CURRENT
- Service 22
DID B003 - Module
7DF → 7EC - Every
180 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 110.869565 A
- Unit
- A
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Voltage EHS_EVCC_VOLTAGE
- Service 22
DID B010 - Module
7DF → 7EC - Every
4 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 675.618556 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Internal
HV battery bus voltage EHS_HVBAT_BUS_VOLTAGEConfirmed
- Service 22
DID B041 - Module
7DF → 7ED - Every
30 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 V
- Unit
- V
0x027F = 639 → = 159.75 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery internal resistance EHS_HVBAT_RESISTANCEConfirmed
- Service 22
DID B045 - Module
7DF → 7ED - Every
60 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5
- Unit
- Number
0x1C9D = 7325 → = 3,662.5
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery raw charge EHS_HVBAT_RAW_SOCConfirmed
HV battery raw charge
- Service 22
DID B046 - Module
7DF → 7ED - Every
30 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00A5 = 165 → = 16.5 %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Modules › 01
HV battery module 01 max temperature EHS_HVBAT_CMU01_MAXTEMPConfirmed
- Service 22
DID B001 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x80 = 128 → = 24 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 01 max voltage EHS_HVBAT_CMU01_MAXVOLTConfirmed
- Service 22
DID B001 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
0x164C = 5708 → = 3.854 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 01 min temperature EHS_HVBAT_CMU01_MINTEMPConfirmed
- Service 22
DID B001 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x80 = 128 → = 24 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 01 min voltage EHS_HVBAT_CMU01_MINVOLTConfirmed
- Service 22
DID B001 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
0x1644 = 5700 → = 3.85 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Modules › 02
HV battery module 02 max temperature EHS_HVBAT_CMU02_MAXTEMPConfirmed
- Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x78 = 120 → = 20 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 02 max voltage EHS_HVBAT_CMU02_MAXVOLTConfirmed
- Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
0x1370 = 4976 → = 3.488 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 02 min temperature EHS_HVBAT_CMU02_MINTEMPConfirmed
- Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x78 = 120 → = 20 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 02 min voltage EHS_HVBAT_CMU02_MINVOLTConfirmed
- Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
0x135A = 4954 → = 3.477 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Modules › 03
HV battery module 03 max temperature EHS_HVBAT_CMU03_MAXTEMPConfirmed
- Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x8A = 138 → = 29 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 03 max voltage EHS_HVBAT_CMU03_MAXVOLTConfirmed
- Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
0x1344 = 4932 → = 3.466 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 03 min temperature EHS_HVBAT_CMU03_MINTEMPConfirmed
- Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x8A = 138 → = 29 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 03 min voltage EHS_HVBAT_CMU03_MINVOLTConfirmed
- Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
0x132A = 4906 → = 3.453 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Modules › 04
HV battery module 04 max temperature EHS_HVBAT_CMU04_MAXTEMPConfirmed
- Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x78 = 120 → = 20 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 04 max voltage EHS_HVBAT_CMU04_MAXVOLTConfirmed
- Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
0x1358 = 4952 → = 3.476 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 04 min temperature EHS_HVBAT_CMU04_MINTEMPConfirmed
- Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x78 = 120 → = 20 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 04 min voltage EHS_HVBAT_CMU04_MINVOLTConfirmed
- Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
0x131A = 4890 → = 3.445 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Modules › 05
HV battery module 05 max temperature EHS_HVBAT_CMU05_MAXTEMPConfirmed
- Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x8A = 138 → = 29 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 05 max voltage EHS_HVBAT_CMU05_MAXVOLTConfirmed
- Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
0x133A = 4922 → = 3.461 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 05 min temperature EHS_HVBAT_CMU05_MINTEMPConfirmed
- Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x8A = 138 → = 29 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 05 min voltage EHS_HVBAT_CMU05_MINVOLTConfirmed
- Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
0x1328 = 4904 → = 3.452 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Modules › 06
HV battery module 06 max temperature EHS_HVBAT_CMU06_MAXTEMPConfirmed
- Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x94 = 148 → = 34 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 06 max voltage EHS_HVBAT_CMU06_MAXVOLTConfirmed
- Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
0x136E = 4974 → = 3.487 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 06 min temperature EHS_HVBAT_CMU06_MINTEMPConfirmed
- Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
0x92 = 146 → = 33 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 06 min voltage EHS_HVBAT_CMU06_MINVOLTConfirmed
- Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
0x1366 = 4966 → = 3.483 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Modules › 07
HV battery module 07 max temperature EHS_HVBAT_CMU07_MAXTEMP
- Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 07 max voltage EHS_HVBAT_CMU07_MAXVOLT
- Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 07 min temperature EHS_HVBAT_CMU07_MINTEMP
- Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 07 min voltage EHS_HVBAT_CMU07_MINVOLT
- Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 08
HV battery module 08 max temperature EHS_HVBAT_CMU08_MAXTEMP
- Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 08 max voltage EHS_HVBAT_CMU08_MAXVOLT
- Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 08 min temperature EHS_HVBAT_CMU08_MINTEMP
- Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 08 min voltage EHS_HVBAT_CMU08_MINVOLT
- Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 09
HV battery module 09 max temperature EHS_HVBAT_CMU09_MAXTEMP
- Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 09 max voltage EHS_HVBAT_CMU09_MAXVOLT
- Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 09 min temperature EHS_HVBAT_CMU09_MINTEMP
- Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 09 min voltage EHS_HVBAT_CMU09_MINVOLT
- Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 10
HV battery module 10 max temperature EHS_HVBAT_CMU10_MAXTEMP
- Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 10 max voltage EHS_HVBAT_CMU10_MAXVOLT
- Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 10 min temperature EHS_HVBAT_CMU10_MINTEMP
- Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 10 min voltage EHS_HVBAT_CMU10_MINVOLT
- Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 11
HV battery module 11 max temperature EHS_HVBAT_CMU11_MAXTEMP
- Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 11 max voltage EHS_HVBAT_CMU11_MAXVOLT
- Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 11 min temperature EHS_HVBAT_CMU11_MINTEMP
- Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 11 min voltage EHS_HVBAT_CMU11_MINVOLT
- Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 12
HV battery module 12 max temperature EHS_HVBAT_CMU12_MAXTEMP
- Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 12 max voltage EHS_HVBAT_CMU12_MAXVOLT
- Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 12 min temperature EHS_HVBAT_CMU12_MINTEMP
- Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 12 min voltage EHS_HVBAT_CMU12_MINVOLT
- Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 13
HV battery module 13 max temperature EHS_HVBAT_CMU13_MAXTEMP
- Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 13 max voltage EHS_HVBAT_CMU13_MAXVOLT
- Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 13 min temperature EHS_HVBAT_CMU13_MINTEMP
- Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 13 min voltage EHS_HVBAT_CMU13_MINVOLT
- Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 14
HV battery module 14 max temperature EHS_HVBAT_CMU14_MAXTEMP
- Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 14 max voltage EHS_HVBAT_CMU14_MAXVOLT
- Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 14 min temperature EHS_HVBAT_CMU14_MINTEMP
- Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 14 min voltage EHS_HVBAT_CMU14_MINVOLT
- Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 15
HV battery module 15 max temperature EHS_HVBAT_CMU15_MAXTEMP
- Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 15 max voltage EHS_HVBAT_CMU15_MAXVOLT
- Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 15 min temperature EHS_HVBAT_CMU15_MINTEMP
- Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 15 min voltage EHS_HVBAT_CMU15_MINVOLT
- Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 16
HV battery module 16 max temperature EHS_HVBAT_CMU16_MAXTEMP
- Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 16 max voltage EHS_HVBAT_CMU16_MAXVOLT
- Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 16 min temperature EHS_HVBAT_CMU16_MINTEMP
- Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 16 min voltage EHS_HVBAT_CMU16_MINVOLT
- Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 17
HV battery module 17 max temperature EHS_HVBAT_CMU17_MAXTEMP
- Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 17 max voltage EHS_HVBAT_CMU17_MAXVOLT
- Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 17 min temperature EHS_HVBAT_CMU17_MINTEMP
- Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 17 min voltage EHS_HVBAT_CMU17_MINVOLT
- Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 18
HV battery module 18 max temperature EHS_HVBAT_CMU18_MAXTEMP
- Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 18 max voltage EHS_HVBAT_CMU18_MAXVOLT
- Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 18 min temperature EHS_HVBAT_CMU18_MINTEMP
- Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 18 min voltage EHS_HVBAT_CMU18_MINVOLT
- Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 19
HV battery module 19 max temperature EHS_HVBAT_CMU19_MAXTEMP
- Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 19 max voltage EHS_HVBAT_CMU19_MAXVOLT
- Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 19 min temperature EHS_HVBAT_CMU19_MINTEMP
- Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 19 min voltage EHS_HVBAT_CMU19_MINVOLT
- Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 20
HV battery module 20 max temperature EHS_HVBAT_CMU20_MAXTEMP
- Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 20 max voltage EHS_HVBAT_CMU20_MAXVOLT
- Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 20 min temperature EHS_HVBAT_CMU20_MINTEMP
- Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 20 min voltage EHS_HVBAT_CMU20_MINVOLT
- Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 21
HV battery module 21 max temperature EHS_HVBAT_CMU21_MAXTEMP
- Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 21 max voltage EHS_HVBAT_CMU21_MAXVOLT
- Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 21 min temperature EHS_HVBAT_CMU21_MINTEMP
- Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 21 min voltage EHS_HVBAT_CMU21_MINVOLT
- Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 22
HV battery module 22 max temperature EHS_HVBAT_CMU22_MAXTEMP
- Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 22 max voltage EHS_HVBAT_CMU22_MAXVOLT
- Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 22 min temperature EHS_HVBAT_CMU22_MINTEMP
- Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 22 min voltage EHS_HVBAT_CMU22_MINVOLT
- Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 23
HV battery module 23 max temperature EHS_HVBAT_CMU23_MAXTEMP
- Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 23 max voltage EHS_HVBAT_CMU23_MAXVOLT
- Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 23 min temperature EHS_HVBAT_CMU23_MINTEMP
- Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 23 min voltage EHS_HVBAT_CMU23_MINVOLT
- Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Modules › 24
HV battery module 24 max temperature EHS_HVBAT_CMU24_MAXTEMP
- Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 24 max voltage EHS_HVBAT_CMU24_MAXVOLT
- Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 24 min temperature EHS_HVBAT_CMU24_MINTEMP
- Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 24 min voltage EHS_HVBAT_CMU24_MINVOLT
- Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2024. Supported for 2021, 2025.
ECU
Vehicle gateway status EHS_GWM_STATUSConfirmed
- Service 22
DID D001 - Module
710 → 718 - Every
4 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Engine
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2024. Supported for 2021, 2025.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2021, 2025.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2024. Supported for 2021.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024. Supported for 2021, 2025.
Engine oil pressure EHS_EOP
- Service 22
DID B036 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1500.7515 kPa
- Unit
- kPa
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Engine oil temperature EHS_EO_T
- Service 22
DID B034 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Misfires, cylinder 1 EHS_MISFIRES_C1
- Service 22
DID B143 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Misfires, cylinder 2 EHS_MISFIRES_C2
- Service 22
DID B144 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Misfires, cylinder 3 EHS_MISFIRES_C3
- Service 22
DID B145 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Misfires, cylinder 4 EHS_MISFIRES_C4
- Service 22
DID B146 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2024. Supported for 2021, 2025.
Transmission fluid temperature, ECU 10472701 and 11194479 EHS_ATF_T_ECU_10472701_11194479
- Service 22
DID B423 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Transmission fluid temperature, ECU 10513229 EHS_ATF_T_ECU_10513229
- Service 22
DID 1940 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2024. Supported for 2021, 2025.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2024. Supported for 2021, 2025.
Fuel
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L/h
- Unit
- L/h
Confirmed for 2024.
Fuel tank level EHS_FUEL_TANK_LEVEL
- Service 22
DID B043 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2021, 2025.
Movement
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2024. Supported for 2021, 2025.
Tires
Front left tire pressure EHS_BCM_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front left tire pressure EHS_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID B001 - Module
724 → 72C - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front left tire temperature EHS_BCM_TT_FL
Pelican can show this parameter as the front left tire temperature.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front left tire temperature EHS_TT_FL
Pelican can show this parameter as the front left tire temperature.
- Service 22
DID B003 - Module
724 → 72C - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front right tire pressure EHS_BCM_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front right tire pressure EHS_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID B001 - Module
724 → 72C - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front right tire temperature EHS_BCM_TT_FR
Pelican can show this parameter as the front right tire temperature.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Front right tire temperature EHS_TT_FR
Pelican can show this parameter as the front right tire temperature.
- Service 22
DID B003 - Module
724 → 72C - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear left tire pressure EHS_BCM_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear left tire pressure EHS_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID B001 - Module
724 → 72C - Every
15 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear left tire temperature EHS_BCM_TT_RL
Pelican can show this parameter as the rear left tire temperature.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear left tire temperature EHS_TT_RL
Pelican can show this parameter as the rear left tire temperature.
- Service 22
DID B003 - Module
724 → 72C - Every
15 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear right tire pressure EHS_BCM_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear right tire pressure EHS_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID B001 - Module
724 → 72C - Every
15 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear right tire temperature EHS_BCM_TT_RR
Pelican can show this parameter as the rear right tire temperature.
- Service 22
DID E209 - Module
740 - Every
15 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Rear right tire temperature EHS_TT_RR
Pelican can show this parameter as the rear right tire temperature.
- Service 22
DID B003 - Module
724 → 72C - Every
15 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Trips
Odometer EHS_GWM_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID B921 - Module
710 → 718 - Every
1 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x000000 = 0 → 0 km
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Odometer, body control module EHS_BCM_ODO
- Service 22
DID E101 - Module
740 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.