Parameters
The Mercedes-Benz SLC-Class has 24 parameters.
● Confirmed◆ In testing○ Supported× Not supported
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2019.
Engine
Boost air temperature SLC_BOOST_AIR_T
- Service 22
DID 0163 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2016 to 2020.
Boost pressure SLC_BOOST_P
- Service 22
DID 0163 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 120 to 135 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2016 to 2020.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2019.
Diesel particulate filter differential pressure SLC_DPF_DIFF_P
- Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2016 to 2020.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019.
Engine oil temperature SLC_EOT
- Service 22
DID 2095 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -54 to 290 °F
- Unit
- °F
In testing for 2016 to 2020.
Exhaust back pressure SLC_EXH_BACK_P
- Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2016 to 2020.
Radiator temperature SLC_RADIATOR_T
- Service 22
DID 2017 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 55327 °F
- Unit
- °F
In testing for 2016 to 2020.
OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2019.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2019.
Fuel
Fuel rail pressure SLC_FUEL_RAIL_P
- Service 22
DID 2071 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32758 kPa
- Unit
- kPa
In testing for 2016 to 2020.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Fuel tank level SLC_FUEL_TANK_LEVEL
- Service 22
DID 2030 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6549 L
- Unit
- L
In testing for 2016 to 2020.
Fuel temperature SLC_FUEL_T
- Service 22
DID 016F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2016 to 2020.
Movement
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2019.
Transmission
Current gear SLC_CURRENT_GEAR
- Service 21
PID 30 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2020.
Torque converter slip SLC_TQ_CONV_SLIP
- Service 21
PID 30 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 rpm
- Unit
- rpm
In testing for 2016 to 2020.
Transmission fluid temperature, variant 1 SLC_ATF_T_VAR_1
- Service 21
PID 30 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2016 to 2020.
Transmission fluid temperature, variant 2 SLC_ATF_T_VAR_2
- Service 22
DID 0230 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2016 to 2020.
Transmission fluid temperature, variant 3 SLC_ATF_T_VAR_3
- Service 21
PID 34 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 72 to 87 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2016 to 2020.
Transmission fluid temperature, variant 4 SLC_ATF_T_VAR_4
- Service 22
DID 0234 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2020.
Trips
Odometer SLC_ODO
- Service 22
DID 016B - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070 km
- Unit
- km
In testing for 2016 to 2020.