Mercedes-Benz S-Class

Parameters

The Mercedes-Benz S-Class has 107 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Auxiliary battery voltage MERCEDES_AUX_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2005
  • Module7E5
  • Every1 s
  • Testing

Example reply from a 2021 Mercedes-Benz S-Class.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25.9255
Range
0 to 25.9 V
Unit
V

0x76 = 118 → 118×25.9255 = 11.985098 V

Confirmed for 2021. In testing for 1996 to 2007, 2009 to 2020, 2022 to 2026. Not supported for 2008.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V system voltage, hd MERCEDES_AUX_V_HD

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 0201
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 100 V
Unit
V

In testing for 1996 to 2007, 2009 to 2020, 2022 to 2026. Not supported for 2008, 2021.

Auxiliary battery voltage MERCEDES_AUX_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2005
  • Module7E5
  • Every1 s
  • Testing

Example reply from a 2021 Mercedes-Benz S-Class.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25.9255
Range
0 to 25.9 V
Unit
V

0x76 = 118 → 118×25.9255 = 11.985098 V

Confirmed for 2021. In testing for 1996 to 2007, 2009 to 2020, 2022 to 2026. Not supported for 2008.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2008, 2016, 2021, 2024. Supported for 2018.

DC converter requested voltage MERCEDES_CNVRTR_REQ_V

  • Service 22DID 6071
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25010000
Range
0 to 100 V
Unit
V

In testing for 1996 to 2007, 2009 to 2020, 2022 to 2026. Not supported for 2008, 2021.

HV battery amperage MERCEDES_HV_A

  • Service 22DID 6053
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
0 to 100 A
Unit
A

In testing for 1996 to 2007, 2009 to 2020, 2022 to 2026. Not supported for 2008, 2021.

HV battery coolant temperature MERCEDES_HV_COOLANT_T

  • Service 22DID 2526
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×125010000
Range
0 to 100 °C
Unit
°C

In testing for 1996 to 2007, 2009 to 2020, 2022 to 2026. Not supported for 2008, 2021.

HV battery state of charge MERCEDES_HV_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 6050
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 1996 to 2007, 2009 to 2020, 2022 to 2026. Not supported for 2008, 2021.

HV battery voltage MERCEDES_HV_VConfirmed

  • Service 22DID 6075
  • Module7E5
  • Every1 s
  • Testing

Example reply from a 2021 Mercedes-Benz S-Class.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×251000
Range
0 to 100 V
Unit
V

0x0000 = 0 → 0×251000 = 0 V

Confirmed for 2021. In testing for 1996 to 2007, 2009 to 2020, 2022 to 2026. Not supported for 2008.

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Climate

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2008, 2016, 2024. Supported for 2021.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Control

Steering wheel angle MERCEDES_STEER_ANGLEConfirmed

Positive is rotated to the right, negative is rotated to the left.

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

0x0010 = 16 → 1610 = 1.6 °

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Engine

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2008, 2016. Supported for 2018, 2021.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2024. Supported for 2021.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2008.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2008, 2016, 2024. Supported for 2010, 2018, 2021.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2008, 2016. Supported for 2010, 2018, 2021.

Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed

  • Service 01PID 3D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2008, 2016. Supported for 2010, 2018, 2021.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2008, 2016, 2021.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008, 2016. Supported for 2010, 2018, 2021.

Commanded secondary air status AIR_STATSAE J1979Confirmed

  • Service 01PID 12
  • Module7E0 → 7E8
  • Every60 s

Bits 5 to 7 of the reply, 3 bits.

Unit
Named states
States
Raw valueStateMeaning
1UPSUpstream of first catalytic converter
2DNSDownstream of first catalytic converter inlet
4OFFAtmosphere / off
8DIAGPump commanded on for diagnostics

Confirmed for 2008. Supported for 2010.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008, 2016.

Distance to next service MERCEDES_SERVICE_DIST

  • Service 22DID 6504
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 1996 to 2007, 2009 to 2020, 2022 to 2026. Not supported for 2008, 2021.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

Engine oil temperature EOTSAE J1979Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 01PID 5C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021, 2024.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2024. Supported for 2021.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2008, 2016, 2024. Supported for 2010, 2018, 2021.

Evap system vapor pressure EVAP_VPSAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Service 01PID 32
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4000
Range
-8192 to 8191.75 kPa
Unit
kPa

Confirmed for 2008. Supported for 2010.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2016, 2024. Supported for 2010, 2018.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2008, 2016. Supported for 2010, 2018.

Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2008, 2016, 2024. Supported for 2010, 2018.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2008, 2016, 2024. Supported for 2010, 2018, 2021.

Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed

  • Service 01PID 09
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2008, 2016. Supported for 2010, 2018, 2021.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2016, 2024. Supported for 2021.

Long term secondary O2 sensor fuel trim (bank 2) LGSO2FT2SAE J1979Confirmed

  • Service 01PID 58
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2016. Supported for 2021.

Master break cylinder pressure MERCEDES_MASTER_BREAK_CYLINDER_PRESSUREConfirmed

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val×15310000
Range
-500 to 500 bar
Unit
bar

0x0461 = 1121 → 1121×15310000 = 17.1513 bar

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2008, 2016, 2024. Supported for 2010, 2018, 2021.

Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 08
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2008, 2016. Supported for 2010, 2018, 2021.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2008, 2016, 2024. Supported for 2010, 2018, 2021.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2016, 2024. Supported for 2021.

Vacuum break pressure MERCEDES_VACUUM_BREAK_PRESSUREConfirmed

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 144 to 159 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 bar
Unit
bar

0x04DD = 1245 → 12451000 = 1.245 bar

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Internal

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2008, 2021, 2024. Supported for 2010, 2016.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2008, 2021, 2024. Supported for 2010, 2016.

Fuel

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2024.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2024.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2024.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2008, 2016, 2024. Supported for 2010, 2018, 2021.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2008, 2016, 2024. Supported for 2010, 2018, 2021.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2008, 2021. Supported for 2016, 2018.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2024.

Movement

Front left wheel speed MERCEDES_FL_VSSConfirmed

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×562.510000
Range
0 to 1000 km/h
Unit
km/h

0x0000 = 0 → 0×562.510000 = 0 km/h

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Front left wheel speed MERCEDES_TIRE_FL_VSSConfirmed

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 1000 km/h
Unit
km/h

0x0000 = 0 → 0×0.05625 = 0 km/h

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Front right wheel speed MERCEDES_FR_VSSConfirmed

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×562.510000
Range
0 to 100 km/h
Unit
km/h

0x0000 = 0 → 0×562.510000 = 0 km/h

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Front right wheel speed MERCEDES_TIRE_FR_VSSConfirmed

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 1000 km/h
Unit
km/h

0x0000 = 0 → 0×0.05625 = 0 km/h

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Rear left wheel speed MERCEDES_RL_VSSConfirmed

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×562.510000
Range
0 to 100 km/h
Unit
km/h

0x0000 = 0 → 0×562.510000 = 0 km/h

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Rear left wheel speed MERCEDES_TIRE_RL_VSSConfirmed

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 1000 km/h
Unit
km/h

0x0000 = 0 → 0×0.05625 = 0 km/h

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Rear right wheel speed MERCEDES_RR_VSSConfirmed

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 48 to 63 of the reply, 16 bits.

Formula
val×562.510000
Range
0 to 100 km/h
Unit
km/h

0x0000 = 0 → 0×562.510000 = 0 km/h

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Rear right wheel speed MERCEDES_TIRE_RR_VSSConfirmed

  • Service 22DID 2001
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 48 to 63 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 1000 km/h
Unit
km/h

0x0000 = 0 → 0×0.05625 = 0 km/h

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2008, 2016, 2021, 2024. Supported for 2010, 2018.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2008, 2016. Supported for 2010, 2018, 2021, 2024.

Orientation

Lateral acceleration MERCEDES_LAT_ACCConfirmed

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val×15.6251000
Range
-512 to 511 g
Unit
g

0x0000 = 0 → 0×15.6251000 = 0 g

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Lateral acceleration MERCEDES_LAT_GConfirmed

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val627.6
Range
-52.21 to 52.21 g
Unit
g

0x0000 = 0 → 0627.6 = 0 g

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Longitudinal acceleration MERCEDES_LNG_GConfirmed

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val192747
Range
-0.17 to 0.17 g
Unit
g

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Longitudinal acceleration MERCEDES_LON_ACCConfirmed

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
val×0.051000
Range
-1.63 to 1.63 g
Unit
g

0x0200 = 512 → 512×0.051000 = 0.0256 g

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Master break cylinder pressure MERCEDES_MCYL_BREAKConfirmed

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val65.35883831
Range
-501.34 to 501.34 bar
Unit
bar

0x0461 = 1121 → 112165.35883831 = 17.151468 bar

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Vaccuum cylinder pressure MERCEDES_VACC_BREAKConfirmed

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 144 to 159 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32 to 32 bar
Unit
bar

0x04DD = 1245 → 12451000 = 1.245 bar

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Yaw rate MERCEDES_YAW_RATEConfirmed

The angular velocity of the car around its vertical axis. Indicates how quickly the car is rotating to its left or right.

  • Service 22DID 2002
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Example reply from a 2016 Mercedes-Benz S-Class.

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val×232767
Range
-2 to 2 rad
Unit
rad

0x004D = 77 → 77×232767 = 0.0047 rad

Confirmed for 2016. In testing for 1996 to 2007, 2009 to 2015, 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2008, 2021, 2024.

Trips

HV battery remaining distance MERCEDES_HV_RANGE

Pelican can show this parameter as the electric range.

  • Service 22DID 6502
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 km
Unit
km

In testing for 1996 to 2007, 2009 to 2020, 2022 to 2026. Not supported for 2008, 2021.

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2021.