Parameters
The Mercedes-Benz A 220 has 45 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V system voltage, hd MERCEDES_AUX_V_HD
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 0201 - Module
624 → 5A4 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 V
- Unit
- V
In testing for 2018 to 2020, 2022 to 2026. Not supported for 2021.
Auxiliary battery voltage MERCEDES_AUX_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 2005 - Module
7E5 - Every
1 s - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.9 V
- Unit
- V
0x7B = 123 → = 12.492941 V
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
DC converter requested voltage MERCEDES_CNVRTR_REQ_VConfirmed
- Service 22
DID 6071 - Module
7E5 - Every
1 s - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 V
- Unit
- V
0x05A0 = 1440 → = 36 V
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
HV battery amperage MERCEDES_HV_AConfirmed
- Service 22
DID 6053 - Module
7E5 - Every
1 s - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 A
- Unit
- A
0x0000 = 0 → = 0 A
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
HV battery coolant temperature MERCEDES_HV_COOLANT_T
- Service 22
DID 2526 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 °C
- Unit
- °C
In testing for 2018 to 2020, 2022 to 2026. Not supported for 2021.
HV battery state of charge MERCEDES_HV_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID 6050 - Module
7E5 - Every
1 s - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x1068 = 4200 → = 42 %
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
HV battery voltage MERCEDES_HV_VConfirmed
- Service 22
DID 6075 - Module
7E5 - Every
1 s - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 V
- Unit
- V
0x0000 = 0 → = 0 V
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Climate
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021.
Steering wheel angle MERCEDES_STEER_ANGLEConfirmed
Positive is rotated to the right, negative is rotated to the left.
- Service 22
DID 2002 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 72 to 87 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
0xFF57 = -169 → = -16.9 °
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2021.
Engine
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2021.
Distance to next service MERCEDES_SERVICE_DIST
- Service 22
DID 6504 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2018 to 2020, 2022 to 2026. Not supported for 2021.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021.
Master break cylinder pressure MERCEDES_MASTER_BREAK_CYLINDER_PRESSUREConfirmed
- Service 22
DID 2002 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 96 to 111 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -500 to 500 bar
- Unit
- bar
0x0010 = 16 → = 0.2448 bar
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2021.
Vacuum break pressure MERCEDES_VACUUM_BREAK_PRESSUREConfirmed
- Service 22
DID 2002 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 bar
- Unit
- bar
0xFC0A = 64522 → = 64.522 bar
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2021.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2021.
Fuel
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2021.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L/h
- Unit
- L/h
Confirmed for 2021.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2021.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2021.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2021.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2021.
Movement
Front left wheel speed MERCEDES_FL_VSSConfirmed
- Service 22
DID 2001 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Front left wheel speed MERCEDES_TIRE_FL_VSSConfirmed
- Service 22
DID 2001 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Front right wheel speed MERCEDES_FR_VSSConfirmed
- Service 22
DID 2001 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Front right wheel speed MERCEDES_TIRE_FR_VSSConfirmed
- Service 22
DID 2001 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Rear left wheel speed MERCEDES_RL_VSSConfirmed
- Service 22
DID 2001 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Rear left wheel speed MERCEDES_TIRE_RL_VSSConfirmed
- Service 22
DID 2001 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Rear right wheel speed MERCEDES_RR_VSSConfirmed
- Service 22
DID 2001 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Rear right wheel speed MERCEDES_TIRE_RR_VSSConfirmed
- Service 22
DID 2001 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2021.
Orientation
Lateral acceleration MERCEDES_LAT_ACCConfirmed
- Service 22
DID 2002 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 24 to 39 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 g
- Unit
- g
0xFFFC = -4 → = -0.0625 g
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Lateral acceleration MERCEDES_LAT_GConfirmed
- Service 22
DID 2002 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 24 to 39 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -52.21 to 52.21 g
- Unit
- g
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Longitudinal acceleration MERCEDES_LNG_GConfirmed
- Service 22
DID 2002 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 8 to 23 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -0.17 to 0.17 g
- Unit
- g
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Longitudinal acceleration MERCEDES_LON_ACCConfirmed
- Service 22
DID 2002 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 8 to 23 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.63 to 1.63 g
- Unit
- g
0x0700 = 1792 → = 0.0896 g
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Master break cylinder pressure MERCEDES_MCYL_BREAKConfirmed
- Service 22
DID 2002 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 96 to 111 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -501.34 to 501.34 bar
- Unit
- bar
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Vaccuum cylinder pressure MERCEDES_VACC_BREAKConfirmed
- Service 22
DID 2002 - Module
7E2 → 7EA - Every
250 ms - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 144 to 159 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32 to 32 bar
- Unit
- bar
0xFC0A = -1014 → = -1.014 bar
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Yaw rate MERCEDES_YAW_RATEConfirmed
The angular velocity of the car around its vertical axis. Indicates how quickly the car is rotating to its left or right.
- Service 22
DID 2002 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2 to 2 rad
- Unit
- rad
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
Trips
HV battery remaining distance MERCEDES_HV_RANGE
Pelican can show this parameter as the electric range.
- Service 22
DID 6502 - Module
7E5 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1000 km
- Unit
- km
In testing for 2018 to 2020, 2022 to 2026. Not supported for 2021.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2021.