Parameters
The Mazda CX-30 has 364 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery state of charge CX30_12V_SOC_723Confirmed
- Service 22
DID DCE2 - Module
723 → 72B - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022. In testing for 2020, 2024. Not supported for 2021, 2023, 2025 to 2026.
12V battery voltage CX30_12V_VOLTAGEConfirmed
- Service 22
DID D90E - Module
723 → 72B - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Example reply from a 2022 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 V
- Unit
- V
0x053F = 1343 → = 13.43 V
Confirmed for 2022. In testing for 2020, 2024. Not supported for 2021, 2023, 2025 to 2026.
Air conditioning load signal voltage CX30_AC_LOAD_SIG_V
- Service 22
DID 03E5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 319.9942 V
- Unit
- V
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Battery accumulated amp hours CX30_BAT_ACCUMULATED_AMP
- Service 22
DID D988 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -100 to 227.675 Ah
- Unit
- Ah
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Battery estimated state of charge CX30_BAT_ESTIMATED_ST_CHG
- Service 22
DID 4028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Battery fluid temperature CX30_BAT_FLUID_TConfirmed
- Service 22
DID 4029 - Module
7E0 → 7E8 - Every
5 s - Testing for 2020, 2022 to 2026
Example reply from a 2021 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x41 = 65 → = 25 °C
Confirmed for 2021. In testing for 2020, 2023 to 2024, 2026. Not supported for 2022, 2025.
Battery internal resistance CX30_BAT_INTERNAL_RES
- Service 22
DID DA9D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.6553 Ω
- Unit
- Ω
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Battery pack voltage CX30_HVBAT_VOLTAGEConfirmed
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 480D - Module
723 → 72B - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Example reply from a 2022 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 V
- Unit
- V
0x0879 = 2169 → = 21.69 V
Confirmed for 2022. In testing for 2020, 2024. Not supported for 2021, 2023, 2025 to 2026.
Battery voltage CX30_BAT_V
- Service 22
DID 1172 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.9375 V
- Unit
- V
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Charge air cooler temperature CX30_CHG_AIR_COOLER_T
- Service 22
DID F477 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Charge air temperature CX30_CHG_AIR_T
- Service 22
DID 051C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Commanded generator voltage CX30_CMD_GEN_VConfirmed
- Service 22
DID 0304 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16 V
- Unit
- V
0x6CE0 = 27872 → = 13.601536 V
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2021 to 2023, 2025. Supported for 2020.
High voltage battery state of charge CX30_HV_EV_BATT_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID D914 - Module
723 → 72B - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Example reply from a 2022 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x01A4 = 420 → = 42 %
Confirmed for 2022. In testing for 2020, 2024. Not supported for 2021, 2023, 2025 to 2026.
Turbocharger a compressor inlet pressure CX30_TURBOCHARGER_COMP_P
- Service 22
DID F46F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 2040 kPa
- Unit
- kPa
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Turbocharger b compressor inlet pressure CX30_TURBOCHARGER_B_COMP_P
- Service 22
DID F46F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 2040 kPa
- Unit
- kPa
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Climate
A/C compressor pressure CX30_AC_PConfirmed
- Service 22
DID 0393 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 psi
- Unit
- psi
0x028A = 650 → = 188.549073 psi
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
A/C compressor pressure sensor voltage CX30_AC_P_SENS_VConfirmed
- Service 22
DID 9800 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
A/C compressor, state CX30_AC_STATEConfirmed
- Service 22
DID 099B - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0x01 = 1 → 1
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
A/C refrigerant pressure CX30_PCM_A_C_REFRIG_P
- Service 22
DID 0604 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 kPa
- Unit
- kPa
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021 to 2023. Supported for 2025.
Ambient air temperature CX30_AATConfirmed
- Service 22
DID DD05 - Module
723 → 72B - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Example reply from a 2022 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x3A = 58 → = 18 °C
Confirmed for 2022. In testing for 2020, 2024. Not supported for 2021, 2023, 2025 to 2026.
Ambient temperature, alternate CX30_AAT_ALTConfirmed
- Service 22
DID 057D - Module
7E0 → 7E8 - Every
5 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 87.5 °C
- Unit
- °C
0x80 = 128 → = 24 °C
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2021 to 2023, 2025. Supported for 2020, 2024, 2026.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2025. Supported for 2020 to 2021, 2024, 2026.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2025.
Brake fluid pressure CX30_BRAKE_FLUID_P
- Service 22
DID 280A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199.2187 kPa
- Unit
- kPa
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Brake hydraulic pressure, raw count CX30_BRK_FL_PConfirmed
- Service 22
DID 2B0D - Module
760 → 768 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Brake switch CX30_BRAKE_SWITCHConfirmed
- Service 22
DID DA05 - Module
726 → 72E - Every
250 ms - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Focus parking brake state CX30_PARKING_BRAKEConfirmed
- Service 22
DID 2B00 - Module
760 → 768 - Every
3 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Relative throttle position TP_RSAE J1979Confirmed
Relative or 'learned' throttle position.
- Service 01
PID 45 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. Supported for 2025.
Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023, 2025. Supported for 2021 to 2022.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023, 2025.
Cruise control
Cruise control speed CX30_CC_S
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Cruise control voltage CX30_SCCS_V
0.0V = On/Off Switch depressed, 1.1V = Cancel depressed, 3.1V = Set/- switch depressed, 4.2V = Res/+ switch depressed, 5.0V = Normal
- Service 22
DID A216 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
CX30
Barometric pressure CX30_BARO
- Service 22
DID 0353 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 8 to 20 psi
- Unit
- psi
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Engine coolant temperature CX30_ECT
- Service 22
DID 038F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 148.889 °C
- Unit
- °C
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Manifold charge temperature CX30_MCT
- Service 22
DID 03CA - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 148.889 °C
- Unit
- °C
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Octane adjust ratio CX30_OARConfirmed
- Service 22
DID 03E8 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2020, 2024
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 1
- Unit
- Number
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
CX30_AAT
Ambient air temperature sensor voltage CX30_AAT_VConfirmed
- Service 22
DID 03BA - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
CX30_ACC
Accelerator pedal position CX30_ACC_POSConfirmed
- Service 22
DID 032B - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
CX30_BARO_V
Barometric pressure sensor voltage CX30_BARO_V_7E0
- Service 22
DID 035A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
CX30_CL
Closed loop lambda correction CX30_CL_LCConfirmed
- Service 22
DID 03BD - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -4 to 3.9
- Unit
- Number
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
CX30_ETC_TRIM
Electronic throttle control learned trim angle CX30_ETC_TRIM_LEARNED
- Service 22
DID 0338 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -64 to 63.9 °
- Unit
- °
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
CX30_EVAP
Evaporative pressure sensor, raw count CX30_EVAP_RAWConfirmed
- Service 22
DID 038E - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0695 = 1685 → 1,685
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
CX30_HPFP
High pressure fuel pressure desired CX30_HPFP_DESConfirmed
- Service 22
DID 03DC - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3500 psi
- Unit
- psi
0x03E8 = 1000 → = 1,450.377397 psi
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
High pressure fuel rail sensor voltage CX30_HPFP_VConfirmed
- Service 22
DID 0324 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0x0105 = 261 → = 1.27566 V
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
CX30_RO2
Rear O2 voltage CX30_RO2_VConfirmed
- Service 22
DID 035F - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1 V
- Unit
- V
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
CX30_TIP
Throttle inlet pressure absolute CX30_TIP_ABS
- Service 22
DID 033E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 60 psi
- Unit
- psi
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Throttle inlet pressure sensor voltage CX30_TIP_V
- Service 22
DID 033C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
CX30_VCT_EXH
Variable cam timing exhaust cam, desired CX30_VCT_EXH_DES
- Service 22
DID 03BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2047 to 2047 °
- Unit
- °
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Variable cam timing exhaust camshaft actual CX30_VCT_EXH_ACTConfirmed
- Service 22
DID 0319 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 50 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Variable cam timing exhaust camshaft error CX30_VCT_EXH_ERR
- Service 22
DID 031B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 50 °
- Unit
- °
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Variable cam timing exhaust camshaft solenoid duty cycle CX30_VCT_EXH_DUTYConfirmed
- Service 22
DID 0317 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
CX30_VCT_INT
Variable cam timing intake cam, desired CX30_VCT_INT_DES
- Service 22
DID 03BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2047 to 2047 °
- Unit
- °
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Variable cam timing intake camshaft error CX30_VCT_INT_ERR
- Service 22
DID 031A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -50 to 50 °
- Unit
- °
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Variable cam timing intake camshaft solenoid duty cycle CX30_VCT_INT_DUTYConfirmed
- Service 22
DID 0316 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0CCD = 3277 → = 10.00061 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Variable camshaft timing, intake camshaft actual CX30_VCT_INT_ACTConfirmed
- Service 22
DID 0318 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2021 to 2023, 2025 to 2026. Supported for 2020, 2024.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
DTC that caused required freeze frame data storage DTCFRZFSAE J1979Confirmed
0 indicates no freeze frame data.
- Service 01
PID 02 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Hexadecimal
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Malfunction indicator lamp CX30_MIL_SW
- Service 22
DID 1103 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Number of DTCs CX30_DTC_CNT
- Service 22
DID 0200 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Number of DTCs CX30_DTC_CNTDConfirmed
- Service 22
DID 0202 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Status
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2020 to 2021, 2023 to 2026.
Emissions
EVAP leak detection pump idle current CX30_LDP_IDL_CURRENT
- Service 22
DID 17F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.036 A
- Unit
- A
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
EVAP leak detection pump incorrect purge flow value CX30_LDP_EVAPCP
- Service 22
DID 17FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.036 A
- Unit
- A
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
EVAP leak detection pump monitoring current CX30_LDP_MON_CURRENT
- Service 22
DID 17F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.036 A
- Unit
- A
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
EVAP leak detection pump reference current CX30_LDP_REF_CURRENT
- Service 22
DID 17F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.036 A
- Unit
- A
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
EVAP leak detection pump small leak detect value CX30_LDP_SL_DV
- Service 22
DID 17F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.036 A
- Unit
- A
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Engine
A/C refrigerant pressure switch CX30_AC_REQ_SW
- Service 22
DID 1104 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
A/C relay CX30_ACCS_SW
- Service 22
DID 1101 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2022, 2025. Supported for 2023.
Accelerator pedal position, full range CX30_APP
- Service 22
DID 1340 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Actual engine percent torque CX30_PCM_ACT_ENG_PCT_TRQConfirmed
- Service 22
DID F462 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x7D = 125 → = 0 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Air conditioning pressure CX30_AC_P_7E0
- Service 22
DID FD18 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 3100 kPa
- Unit
- kPa
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2022, 2025. Supported for 2020 to 2021, 2023 to 2024, 2026.
Air/fuel ratio, actual CX30_AIR_FUEL_RAT_ACT
- Service 22
DID 174F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 29.274
- Unit
- Number
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
APP sensor 1 voltage CX30_APP1_VConfirmed
- Service 22
DID 0914 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
0x0319 = 793 → = 0.793 V
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
APP sensor 2 voltage CX30_APP2_VConfirmed
- Service 22
DID 0915 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
0x0190 = 400 → = 0.4 V
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
BARO sensor voltage CX30_BARO_V
- Service 22
DID 16B3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Barometric pressure CX30_BAROMETRIC_P
- Service 22
DID 1127 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1079.4118 kPa
- Unit
- kPa
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Barometric pressure CX30_BAROMETRIC_P_7E0Confirmed
- Service 22
DID F433 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
0x63 = 99 → 99 kPa
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Boost CX30_BOOST
- Service 22
DID 1440 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 psi
- Unit
- psi
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Boost, desired CX30_BOOST_DES
- Service 22
DID 1305 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10.23 bar
- Unit
- bar
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Boosted air temperature CX30_BOOSTED_AIR_T
- Service 22
DID 1723 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -39.4 to 119 °C
- Unit
- °C
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Brake on/off switch CX30_BOO_SW
- Service 22
DID 1101 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Brake pressure applied switch CX30_BPA_SW
- Service 22
DID A211 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Bypass valve CX30_BPV_OPEN
- Service 22
DID 0427 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2025. Supported for 2020 to 2021, 2024, 2026.
Catalyst damaging misfires total during this trip CX30_CATDMG_MIS_TOTConfirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Catalyst damaging misfires, cylinder 1 CX30_CATDMG_MIS_1Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Catalyst damaging misfires, cylinder 2 CX30_CATDMG_MIS_2Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Catalyst damaging misfires, cylinder 3 CX30_CATDMG_MIS_3Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Catalyst damaging misfires, cylinder 4 CX30_CATDMG_MIS_4Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Catalyst temperature CX30_CAT_TEMPConfirmed
- Service 22
DID F43C - Module
7E0 → 7E8 - Every
5 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x0E19 = 3609 → = 320.9 °C
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Charge air temperature CX30_CAT
- Service 22
DID 0461 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 189 °C
- Unit
- °C
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Charge air temperature sensor voltage CX30_CAT_SENS_V
- Service 22
DID 0460 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2021 to 2023, 2025 to 2026.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022. Supported for 2023, 2025.
Cooling fan duty cycle CX30_COOLING_FAN_DUTYConfirmed
- Service 22
DID 03B9 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2026
Example reply from a 2022 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2021 to 2022. In testing for 2020, 2023 to 2024, 2026. Not supported for 2025.
Cooling fan relay control CX30_FAN1_SW
- Service 22
DID 1103 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Cooling fan relay control CX30_FAN2_SW
- Service 22
DID 1103 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Cooling fan relay control CX30_FAN3_SW
- Service 22
DID 0967 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Cylinder 1 misfire count CX30_MIS_CNT_1
- Service 22
DID 160E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Cylinder 2 misfire count CX30_MIS_CNT_2
- Service 22
DID 160F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Cylinder 3 misfire count CX30_MIS_CNT_3
- Service 22
DID 1610 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Cylinder 4 misfire count CX30_MIS_CNT_4
- Service 22
DID 1611 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Cylinder head temperature CX30_CYL_HEAD_T
- Service 22
DID 051D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Cylinder head temperature CX30_CYL_HEAD_T_7E0
- Service 22
DID 1624 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °F
- Unit
- °F
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Cylinder head temperature CX30_PCM_CYL_HEAD_T_CORR
- Service 22
DID 0334 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Cylinder head temperature, alternate CX30_CYL_HEAD_T_ALT
- Service 22
DID 1685 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 18415 °F
- Unit
- °F
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Cylinder head temperature, sensor 2 CX30_PCM_CYL_HEAD_T_SENS_2_RAW
- Service 22
DID 05FC - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Distance since DTC clear CX30_DIST_DTC_CLRConfirmed
- Service 22
DID F431 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x10E1 = 4321 → 4,321 km
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Distance with MIL CX30_MIL_DISTConfirmed
- Service 22
DID F421 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x0000 = 0 → 0 km
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Emission failure misfires total during this trip CX30_EMISSION_FAILURE_MISConfirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Emission failure misfires, cylinder 1 CX30_EMISSION_FAILURE_MIS_1Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Emission failure misfires, cylinder 2 CX30_EMISSION_FAILURE_MIS_2Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Emission failure misfires, cylinder 3 CX30_EMISSION_FAILURE_MIS_3Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Emission failure misfires, cylinder 4 CX30_EMISSION_FAILURE_MIS_4Confirmed
- Service 22
DID 053B - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Engine coolant temp voltage CX30_ECT_V
- Service 22
DID 114D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022 to 2023, 2025. Supported for 2020 to 2021, 2024, 2026.
Engine load CX30_ENG_LOAD_PCTConfirmed
Pelican can show this parameter as the engine load.
- Service 22
DID F404 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x27 = 39 → = 15.294118 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Engine load, actual CX30_ENG_LOAD_ACTConfirmed
Pelican can show this parameter as the engine load.
- Service 22
DID F443 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
0x001B = 27 → = 10.588235 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Engine oil pressure CX30_EOPConfirmed
- Service 22
DID 0415 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 kPa
- Unit
- kPa
0x008A = 138 → 138 kPa
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Engine oil temperature CX30_EOTConfirmed
- Service 22
DID 1310 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 615.35 °C
- Unit
- °C
0x1D36 = 7478 → = 34.78 °C
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Engine oil temperature CX30_EOT_F4
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID F45C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Engine oil temperature CX30_EOT_V1
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Engine oil temperature 2 CX30_EOT_2
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 111F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Engine reference torque CX30_PCM_ENG_REFERENCE_TRQConfirmed
- Service 22
DID F463 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
0x012C = 300 → 300 N·m
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Engine RPM CX30_ENGINE_RPMConfirmed
- Service 22
DID F40C - Module
723 → 72B - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Example reply from a 2022 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
0x0AF1 = 2801 → = 700.25 rpm
Confirmed for 2022. In testing for 2020, 2024. Not supported for 2021, 2023, 2025 to 2026.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2022, 2025. Supported for 2020 to 2021, 2023 to 2024, 2026.
Engine run time CX30_ENGINE_RUN_TIMEConfirmed
- Service 22
DID F41F - Module
723 → 72B - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Example reply from a 2022 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
0x0006 = 6 → 6 s
Confirmed for 2022. In testing for 2020, 2024. Not supported for 2021, 2023, 2025 to 2026.
Engine run time CX30_ERT
- Service 22
DID 1126 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 s
- Unit
- s
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Engine run time CX30_RUN_TIMEConfirmed
- Service 22
DID F41F - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
0x002D = 45 → 45 s
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Engine runtime CX30_IG_ON_TIMERConfirmed
- Service 22
DID DCE1 - Module
723 → 72B - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Example reply from a 2022 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1092.25 min
- Unit
- min
0x001B = 27 → = 0.45 min
Confirmed for 2022. In testing for 2020, 2024. Not supported for 2021, 2023, 2025 to 2026.
Engine speed CX30_RPMConfirmed
- Service 22
DID F40C - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
0x0BA2 = 2978 → = 744.5 rpm
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Evaporative purge CX30_EVAP_PURGE_CMDConfirmed
- Service 22
DID 1166 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Exhaust differential pressure CX30_EXH_DIFF_P
This sensor is crucial for monitoring how clogged the DPF has become. It measures the pressure before and after the DPF in the exhaust system, with the difference between these two measurements indicating how restricted the filter has become. When the pressure difference becomes too high (indicating a clogged filter), the ECM will initiate a regeneration process to burn off the accumulated soot and clean the filter.
- Service 22
DID 03DB - Module
7E0 → 7E8 - Every
251 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.5 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Exhaust gas recirculation CX30_EGRConfirmed
- Service 22
DID F42C - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2022 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → 0 %
Confirmed for 2021, 2025. In testing for 2020, 2023 to 2024, 2026. Not supported for 2022.
Exhaust gas recirculation a error CX30_EGR_ERRORConfirmed
- Service 22
DID F469 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2187 %
- Unit
- %
0x80 = 128 → = 0 %
Confirmed for 2025. In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022.
Exhaust gas recirculation a valve position CX30_EGR_VLV_POSConfirmed
- Service 22
DID F469 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2025. In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022.
Exhaust gas recirculation a valve position, desired CX30_EGR_VLV_POS_DESConfirmed
- Service 22
DID F469 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2025. In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022.
Exhaust gas recirculation b error CX30_EGR_B_ERROR
- Service 22
DID F469 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020 to 2024, 2026
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2187 %
- Unit
- %
In testing for 2020, 2023 to 2024, 2026. Supported for 2025. Not supported for 2021 to 2022.
Exhaust gas recirculation b valve position CX30_EGR_B_VLV_POSConfirmed
- Service 22
DID F469 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2025. In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022.
Exhaust gas recirculation b valve position, desired CX30_EGR_B_VLV_POS_DESConfirmed
- Service 22
DID F469 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2025. In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022.
Exhaust gas recirculation duty cycle CX30_EGR_DUTY
- Service 22
DID 113C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Exhaust gas recirculation open CX30_EGR_OPEN_MM
Monitors the physical position of the EGR valve, which controls the amount of exhaust gas being recirculated back into the engine's intake system.
- Service 22
DID 0306 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 mm
- Unit
- mm
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Exhaust gas recirculation open CX30_EGR_OPEN_PERC
- Service 22
DID 03FB - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Exhaust gas recirculation purge steps CX30_EGRP_STEPS
- Service 22
DID 098E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Exhaust gas temperature 1 CX30_EXH_GAS_T_1
- Service 22
DID 03F4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 °C
- Unit
- °C
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Exhaust gas temperature 2 CX30_EXH_GAS_T_2
- Service 22
DID 03F5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 °C
- Unit
- °C
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Fuel pressure sensor voltage, low CX30_LPFP_SENS_V
- Service 22
DID 054D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Fuel pressure, low actual CX30_LPFP_ACT
- Service 22
DID 0548 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 200 psi
- Unit
- psi
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Fuel pressure, low desired CX30_LPFP_DES
- Service 22
DID 041F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 110 psi
- Unit
- psi
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Fuel trim, long term CX30_LTFTConfirmed
- Service 22
DID F407 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
0x7C = 124 → = -3.125 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Fuel trim, short term CX30_STFTConfirmed
Pelican can show this parameter as the short term fuel trim.
- Service 22
DID F406 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
0x79 = 121 → = -5.46875 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Generator control CX30_GEN_CTRLConfirmed
- Service 22
DID 0378 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Generator current CX30_GEN_CURRENT
- Service 22
DID 04F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511.8361 to 511.8205 A
- Unit
- A
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Generator field coil control duty CX30_GEN_FCConfirmed
- Service 22
DID 16E8 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 %
- Unit
- %
0x2082 = 8322 → = 25.397116 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Generator output voltage CX30_GEN_VConfirmed
- Service 22
DID 16E9 - Module
7E0 → 7E8 - Every
5 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 8191.875 V
- Unit
- V
0x006F = 111 → = 13.875 V
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Generator voltage desired CX30_GEN_DSD_V
- Service 22
DID 097C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 31.99 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Generator warning light CX30_GEN_CHRGLP
- Service 22
DID 0968 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Grill shutter duty cycle CX30_GRILL_SHUT_DCConfirmed
- Service 22
DID 0707 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x11 = 17 → = 6.666667 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Grill shutter position CX30_GRILL_SHUTTER_POSConfirmed
- Service 22
DID 0580 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x12 = 18 → = 7.058824 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
High detonation switch CX30_HIDET_SW
- Service 22
DID 1706 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Idle speed CX30_IDLE
- Service 22
DID 096E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Idle validation switch CX30_IVS_SW
- Service 22
DID A211 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Ignition correction, cylinder 1 CX30_IGN_CORR_CYL1Confirmed
- Service 22
DID 03EC - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -64 to 63.9 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Ignition timing, cylinder 1 CX30_IGN_TIM_CYL1
- Service 22
DID 116B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -80 to 80 °
- Unit
- °
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Injection mode CX30_INJ_MODE
- Service 22
DID 046F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Injector impulse width CX30_INJ_IMPULSE_WIDTH
- Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.05 s
- Unit
- s
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Intake air temp voltage CX30_IAT_V
- Service 22
DID 114A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Intake air temperature 2 CX30_IAT_2
- Service 22
DID 16A8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -17.77 to 36390 °C
- Unit
- °C
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Intake manifold absolute pressure CX30_INT_MAP
- Service 22
DID F470 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047 kPa
- Unit
- kPa
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Intake manifold absolute pressure, desired CX30_INT_MAP_DES
- Service 22
DID F470 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047 kPa
- Unit
- kPa
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Intake manifold runner control CX30_IMRC_SW
- Service 22
DID 1103 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Intake shutter valve position CX30_INT_SHUTTER_VLV_POSConfirmed
- Service 22
DID F411 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x19 = 25 → = 9.803922 %
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Intake temperature fault CX30_IAT_FAULTConfirmed
- Service 22
DID 0700 - Module
7E0 → 7E8 - Every
5 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Intake temperature sensor voltage CX30_IAT_SENS_VConfirmed
- Service 22
DID 1279 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Intake temperature, alternate CX30_IAT_ALT2Confirmed
- Service 22
DID F40F - Module
7E0 → 7E8 - Every
5 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x40 = 64 → = 24 °C
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Knock counter, cylinder 1 CX30_PCM_CYL_1_KNK_COMB_PERF_CNT
- Service 22
DID 05AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Knock counter, cylinder 2 CX30_PCM_CYL_2_KNK_COMB_PERF_CNT
- Service 22
DID 05AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Knock counter, cylinder 3 CX30_PCM_CYL_3_KNK_COMB_PERF_CNT
- Service 22
DID 05AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Knock counter, cylinder 4 CX30_PCM_CYL_4_KNK_COMB_PERF_CNT
- Service 22
DID 05AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Knock retard CX30_KNOCKR
- Service 22
DID 1746 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 89.78 °
- Unit
- °
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Knock sensor, 1 CX30_KS1_RAW
- Service 22
DID 0403 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Knock sensor, 2 CX30_KS2_RAW
- Service 22
DID 0404 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Lambda modification switch CX30_LAMBDA_MOD_SW
- Service 22
DID 1706 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Lambda, commanded CX30_CL
The ratio of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.
- Service 22
DID 030F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.9999
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Manifold absolute pressure sensor voltage CX30_MAPConfirmed
A properly functioning sensor should read around 1 to 1.5 volts at idle.
- Service 22
DID 0301 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4 V
- Unit
- V
0x034B = 843 → = 0.843 V
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Manifold absolute pressure voltage CX30_MAP_V
- Service 22
DID 0900 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Manifold absolute pressure, high resolution CX30_MAP_HIRES
- Service 22
DID 0370 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 kPa
- Unit
- kPa
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Manifold pressure CX30_MAP_7E0Confirmed
- Service 22
DID F40B - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 36 psi
- Unit
- psi
0x12 = 18 → = 2.610701 psi
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Mass Air Flow Sensor A MAFASAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2022, 2025. Supported for 2023.
Mass Air Flow Sensor B MAFBSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2022, 2025. Supported for 2023.
Mass air-flow voltage CX30_MAF_V
- Service 22
DID 1177 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Misfire acceleration, cylinder 1 CX30_PCM_MISF_ACCEL_CYL1_NORM
- Service 22
DID 0382 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2 to 1.98
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Misfire acceleration, cylinder 2 CX30_PCM_MISF_ACCEL_CYL2_NORM
- Service 22
DID 0388 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2 to 1.98
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Misfire acceleration, cylinder 3 CX30_PCM_MISF_ACCEL_CYL3_NORM
- Service 22
DID 038A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2 to 1.98
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Misfire acceleration, cylinder 4 CX30_PCM_MISF_ACCEL_CYL4_NORM
- Service 22
DID 038B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2 to 1.98
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Misfire events, latest cycle CX30_PCM_MISF_EVENTS_LATEST_CYC
- Service 22
DID 0345 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
O2 sensor 1 heater control, front CX30_O2S_HTR11_SW
- Service 22
DID 1631 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
O2 sensor 1-2 voltage CX30_O2S12_A_V
- Service 22
DID 1174 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 63.99 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
O2 sensor 2 heater control, rear CX30_O2S_HTR12_SW
- Service 22
DID 1631 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Oil dilution events CX30_OIL_DIL_CNT
Monitors fuel dilution in your engine oil, which is when fuel (gasoline) mixes with the engine oil in the crankcase.
- Service 22
DID 0435 - Module
7E0 → 7E8 - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Oil life remaining CX30_PCM_ENG_OIL_LIFE_REM
- Service 22
DID 054B - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Oil pressure solenoid valve, open CX30_OIL_P_SOLENOID_VLVConfirmed
- Service 22
DID DA01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Oxygen concentration CX30_OXY
- Service 22
DID 0451 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Power steering position switch CX30_PSP_SW
- Service 22
DID 1101 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Rear O2 sensor fuel trim CX30_O2S12_FT
- Service 22
DID 163E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 799.98 %
- Unit
- %
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2022 to 2023, 2025. Supported for 2020 to 2021, 2024, 2026.
Sump oil temperature measured CX30_SUMP_OIL_T_MEAS
- Service 22
DID 03F3 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Throttle control desired CX30_ETC_DSD_DEGConfirmed
- Service 22
DID 091A - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 127.9 °
- Unit
- °
0x008D = 141 → = 0.275391 °
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Throttle inlet pressure, desired CX30_TIP_DES_ABS
- Service 22
DID 0466 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 72.5 psi
- Unit
- psi
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Throttle position 1 voltage CX30_TP1_VConfirmed
- Service 22
DID 0917 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
0x0248 = 584 → = 0.584 V
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Throttle position 2 voltage CX30_TP2_VConfirmed
- Service 22
DID 0918 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
0x0E49 = 3657 → = 3.657 V
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Throttle position actual CX30_ETC_ACT_DEGConfirmed
- Service 22
DID 093C - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 127.9 °
- Unit
- °
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Throttle position closed voltage CX30_TPCT
- Service 22
DID 1169 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 V
- Unit
- V
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Time since last oil change CX30_TIME_SINCE_OIL
- Service 22
DID 053F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000
- Unit
- Raw value
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Timing chain elongation angle CX30_TIM_CHAIN_ELONGATION
- Service 22
DID DAA1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32.76 to 32.76
- Unit
- Number
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Timing chain elongation angle 2 CX30_TIM_CHAIN_ELONGATION_2
- Service 22
DID DAA1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -32.76 to 32.76
- Unit
- Number
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Torque converter lock-up CX30_TQ_CONV_LOCK_UPConfirmed
- Service 22
DID 1E24 - Module
7E1 → 7E9 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Torque converter slip CX30_TQ_CONV_SLIP
- Service 22
DID 11B8 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 39996.0104 rpm
- Unit
- rpm
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Torque into torque converter CX30_TQ_INTO_TQ_CONV
- Service 22
DID 09CB - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 48336.1353 N·m
- Unit
- N·m
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Torque into torque converter CX30_TQ_INTO_TQ_CONV_7E0
- Service 22
DID 163A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 69.1467 N·m
- Unit
- N·m
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Torque request CX30_TRQ_CTRL_REQ
- Service 22
DID 03AF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Torque, actual CX30_TQ_ACTConfirmed
- Service 22
DID 1EE4 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 N·m
- Unit
- N·m
0x0000 = 0 → = 0 N·m
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Torque, desired CX30_TQ_DESConfirmed
- Service 22
DID 1EC7 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 N·m
- Unit
- N·m
0x0000 = 0 → = 0 N·m
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Total misfire count CX30_TOT_MIS_CNT
- Service 22
DID 1616 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transfer case fluid temperature CX30_TRANSFER_CASE_FLUID_T
- Service 22
DID 070D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °C
- Unit
- °C
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transmission fluid temperature, variant 1 CX30_ATF_T_VAR_1
- Service 22
DID 1674 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 8191 °F
- Unit
- °F
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transmission fluid temperature, variant 2 CX30_ATF_T_VAR_2
- Service 22
DID 1674 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °F
- Unit
- °F
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transmission fluid temperature, variant 5 CX30_ATF_T_VAR_5
- Service 22
DID 1E3F - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transmission fluid temperature, variant 6 CX30_ATF_T_VAR_6
- Service 22
DID 092C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °F
- Unit
- °F
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transmission oil temperature CX30_TOT_7E0
- Service 22
DID 1E1C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -500 to 500 °C
- Unit
- °C
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Turbo boost CX30_TURBO_BOOST
- Service 22
DID 09DB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Turbo inlet pressure CX30_TURBO_INLET_P
- Service 22
DID 05BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Valve timing actual CX30_VT_ACT
- Service 22
DID 16CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 °
- Unit
- °
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Valve timing error CX30_VT_DIFF
- Service 22
DID 16CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 °
- Unit
- °
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Valve timing OCV control duty CX30_VT_DUTY
- Service 22
DID 16CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 %
- Unit
- %
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Variable geometry turbocharger open CX30_VGT_OPEN
- Service 22
DID 050F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 mm
- Unit
- mm
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Variable geometry turbocharger open CX30_VGT_OPEN_PERCConfirmed
Measures the position of the vanes in the Variable Geometry Turbocharger (VGT) and reports this position as a percentage value.
- Service 22
DID 03DF - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020 to 2021, 2023 to 2026
Example reply from a 2022 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x1A92 = 6802 → = 10.379187 %
Confirmed for 2022. In testing for 2020, 2024. Not supported for 2021, 2023, 2025 to 2026.
Variable intake air control CX30_IMTV_SW
- Service 22
DID 160D - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Variable valve timing oil temperature CX30_VVTOT
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Warm-ups since DTC clear CX30_WARMUP_CLRConfirmed
- Service 22
DID F430 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0xFF = 255 → 255
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Wastegate duty cycle CX30_WASTEGATE_DUTY
- Service 22
DID 16E1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Wastegate duty cycle CX30_WGDC
- Service 22
DID 0462 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Internal
MAF Sensor A supported MAFA_SUPSAE J1979Confirmed
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022, 2025. Supported for 2023.
MAF Sensor B supported MAFB_SUPSAE J1979Confirmed
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022, 2025. Supported for 2023.
OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2021 to 2023, 2025 to 2026.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2021 to 2023, 2025 to 2026.
Fluids
Distance since oil changed CX30_OIL_CHANGE_DIST
- Service 22
DID 0519 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262140 km
- Unit
- km
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Max distance to oil change CX30_OIL_CHANGE_DIST_MAX
- Service 22
DID 0542 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Fuel
Air/fuel ratio CX30_AIR_FUEL_RATConfirmed
- Service 22
DID F434 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.2801
- Unit
- Number
0x6FEC = 28652 → = 12.801341
Confirmed for 2021 to 2022, 2025. In testing for 2020, 2023 to 2024, 2026.
Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2022. Supported for 2025.
Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2022. Supported for 2025.
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2022. Supported for 2025.
Engine fuel rate CX30_ENG_FUEL_RATEConfirmed
- Service 22
DID F45E - Module
7E0 → 7E8 - Every
1 s - Testing for 2020 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L
- Unit
- L
0x0000 = 0 → = 0 L
Confirmed for 2022, 2025. In testing for 2020, 2023 to 2024, 2026. Not supported for 2021.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L/h
- Unit
- L/h
Confirmed for 2022 to 2023, 2025 to 2026.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2022. Supported for 2025.
Fuel injection impulse width CX30_FUEL_INJ_IMPULSE
- Service 22
DID 168B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.1 s
- Unit
- s
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Fuel level CX30_FLIConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID F42F - Module
7E0 → 7E8 - Every
30 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x8F = 143 → = 56.078431 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Fuel level CX30_FLI_7E0
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 16C1 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 %
- Unit
- %
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Fuel level CX30_FUEL_LEVELConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 61B1 - Module
720 → 728 - Every
1 s - Testing for 2020, 2024
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 55 L
- Unit
- L
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Fuel pump duty cycle CX30_FP_LDConfirmed
- Service 22
DID 0307 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x397D = 14717 → = 44.91272 %
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Fuel pump duty cycle CX30_FUEL_PMP_DUTY
- Service 22
DID 1672 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 199.2187 %
- Unit
- %
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Fuel pump relay switch CX30_FP_RELAY_SW
- Service 22
DID 1718 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Fuel Rail Pressure A FRP_ASAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2022. Supported for 2025.
Fuel Rail Pressure B FRP_BSAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2022. Supported for 2025.
Fuel Rail Temperature A FRT_ASAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022. Supported for 2025.
Fuel Rail Temperature B FRT_BSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022. Supported for 2025.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021 to 2023, 2025. Supported for 2020, 2024, 2026.
Fuel tank pressure CX30_FUEL_TANK_P
- Service 22
DID 1639 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9496.0214 psi
- Unit
- psi
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Fuel temp CX30_FUEL_TConfirmed
- Service 22
DID 0522 - Module
7E0 → 7E8 - Every
1 s - Testing for 2020, 2024, 2026
Example reply from a 2025 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x19 = 25 → = -15 °C
Confirmed for 2021 to 2023, 2025. In testing for 2020, 2024. Not supported for 2026.
Injector fuel pulse width CX30_FUEL_PW
- Service 22
DID 1410 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 524.28
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2022. Supported for 2025.
Internal
Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2025.
Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2025.
Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2025.
Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2025.
Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2025.
Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed
- Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2025.
Movement
Accelerator pedal position CX30_ACCEL_PEDAL_POS
- Service 22
DID 09D4 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Fan speed sensor CX30_FAN_SPD_SENS
- Service 22
DID 099F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Front left wheel speed CX30_FL_VSSConfirmed
- Service 22
DID 2B07 - Module
760 → 768 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Front right wheel speed CX30_FR_VSSConfirmed
- Service 22
DID 2B06 - Module
760 → 768 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Lateral acceleration, raw count CX30_LAT_G_760Confirmed
- Service 22
DID 2B11 - Module
760 → 768 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Lateral angle, raw count CX30_LAT_ANGConfirmed
- Service 22
DID 2B0C - Module
760 → 768 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Rear left wheel speed CX30_RL_VSSConfirmed
- Service 22
DID 2B09 - Module
760 → 768 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Rear right wheel speed CX30_RR_VSSConfirmed
- Service 22
DID 2B08 - Module
760 → 768 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Vehicle speed CX30_VEHICLE_SPEEDConfirmed
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
723 → 72B - Every
1 s - Testing for 2020 to 2021, 2023 to 2024, 2026
Example reply from a 2022 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2022. In testing for 2020, 2024. Supported for 2025. Not supported for 2021, 2023, 2026.
Vehicle speed CX30_VSSConfirmed
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2021 to 2023, 2025. Supported for 2020, 2024, 2026.
Vehicle speed, high resolution CX30_VSS_HD
- Service 22
DID 1505 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2022 to 2023, 2025. Supported for 2020 to 2021, 2024, 2026.
Tires
Front left pressure CX30_TP_FLConfirmed
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID D922 - Module
726 → 72E - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 psi
- Unit
- psi
0xAF = 175 → = 35 psi
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Front left temperature CX30_TT_FLConfirmed
Pelican can show this parameter as the front left tire temperature.
- Service 22
DID D926 - Module
726 → 72E - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
0x48 = 72 → = 22 °C
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Front right pressure CX30_TP_FRConfirmed
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID D923 - Module
726 → 72E - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 psi
- Unit
- psi
0xAA = 170 → = 34 psi
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Front right temperature CX30_TT_FRConfirmed
Pelican can show this parameter as the front right tire temperature.
- Service 22
DID D927 - Module
726 → 72E - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
0x48 = 72 → = 22 °C
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Rear left pressure CX30_TP_RLConfirmed
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID D924 - Module
726 → 72E - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 psi
- Unit
- psi
0xB0 = 176 → = 35.2 psi
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Rear left temperature CX30_TT_RLConfirmed
Pelican can show this parameter as the rear left tire temperature.
- Service 22
DID D928 - Module
726 → 72E - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
0x47 = 71 → = 21 °C
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Rear right pressure CX30_TP_RRConfirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID D925 - Module
726 → 72E - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 psi
- Unit
- psi
0xB1 = 177 → = 35.4 psi
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Rear right temperature CX30_TT_RRConfirmed
Pelican can show this parameter as the rear right tire temperature.
- Service 22
DID D929 - Module
726 → 72E - Every
1 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
0x48 = 72 → = 22 °C
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Tire revolutions per mile CX30_TIRESIZE
- Service 22
DID 16F0 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Transmission
Axle gear ratio, measured CX30_AXLE_GEAR_RATIO_MEAS
- Service 22
DID 1E16 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Clutch pedal position switch CX30_CPP_SW
- Service 22
DID A211 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Converter speed ratio CX30_CONV_SPD_RAT
- Service 22
DID 11BA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3996.0365
- Unit
- Number
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Current gear CX30_GEAR
The automatic transmission gear.
- Service 22
DID 1E12 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
9 | 9 | Ninth gear |
10 | 10 | Tenth gear |
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Gear CX30_GEAR_7E1Confirmed
- Service 22
DID 1E12 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Gear ratio, commanded CX30_PCM_CMD_TRANS_GEAR_RATIO
- Service 22
DID 1E19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Gear, engaged CX30_GEAR_ENGConfirmed
- Service 22
DID 1E1F - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
In gear switch CX30_INGEAR_SW
- Service 22
DID 1101 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Park neutral position switch CX30_PNP_SW
- Service 22
DID A211 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Shift gear CX30_GEAR_SHFT
- Service 22
DID 1E23 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
10 | MANUAL | Manual |
46 | DRIVE | Drive |
50 | NEUTRAL | Neutral |
60 | REVERSE | Reverse |
70 | PARK | Park |
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Torque converter line pressure CX30_TQ_CONV_LINE_P
- Service 22
DID 11C0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8790.819 kPa
- Unit
- kPa
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Torque into torque converter, variant 2 CX30_TQ_INTO_TQ_CONV_VAR_2
- Service 22
DID 163A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 69.1467 N·m
- Unit
- N·m
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transmission fluid temperature CX30_TRANS_TConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1E1C - Module
7E1 → 7E9 - Every
5 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 300 °C
- Unit
- °C
0x01F2 = 498 → = 31.125 °C
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Transmission gear CX30_TRANS_GEAR
- Service 22
DID 11B3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5
- Unit
- Number
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transmission gear CX30_TRANS_GEAR_7E1
- Service 22
DID 11B3 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5
- Unit
- Number
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transmission gear ratio CX30_TRANS_GEAR_RAT
- Service 22
DID 163B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 4015.748
- Unit
- Number
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transmission odometer CX30_TRANS_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
7E1 → 7E9 - Every
30 s - Testing for 2020, 2024, 2026
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
Confirmed for 2021 to 2023, 2025. In testing for 2020, 2024, 2026.
Transmission output shaft speed CX30_TRANS_OUTPUT_SHFT
- Service 22
DID 11B5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1638.375 rpm
- Unit
- rpm
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transmission pressure, commanded CX30_PCM_CMD_TRANS_MAIN_LINE_P
- Service 22
DID 1E1A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534 kPa
- Unit
- kPa
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Transmission temperature CX30_TT
- Service 22
DID 1E1C - Module
7E6 → 7EE - Every
5 s - Testing for 2020 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -300 to 300 °C
- Unit
- °C
In testing for 2020, 2024. Supported for 2023. Not supported for 2021 to 2022, 2025 to 2026.
Transmission temperature v5 CX30_TRANS_T_V5
- Service 22
DID 17B3 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -57 to 371.4 °F
- Unit
- °F
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Transmission temperature, pan CX30_ATF_PAN_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID 82 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Transmission temperature, torque converter CX30_ATF_TQC_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID 82 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Transmission temperature, variant 1 CX30_TRANS_T_VAR_1
- Service 22
DID 17B3 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -57 to 371.4 °F
- Unit
- °F
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transmission temperature, variant 5 CX30_TRANS_T_VAR_5
- Service 22
DID 11BD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7404.6875 °F
- Unit
- °F
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Transmission temperature, variant 6 CX30_TRANS_T_VAR_6
- Service 22
DID 11BD - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7404.6875 °F
- Unit
- °F
In testing for 2020, 2023 to 2024, 2026. Not supported for 2021 to 2022, 2025.
Trips
Distance to empty, calculated CX30_DTE
Pelican can show this parameter as the fuel range.
- Service 22
DID 4194 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Distance to empty, displayed CX30_DTE_DISP
Pelican can show this parameter as the fuel range.
- Service 22
DID 4195 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Odometer CX30_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
7E0 → 7E8 - Every
30 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x0010FA = 4346 → 4,346 km
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2021 to 2023, 2025.
Odometer, instrument panel CX30_ODO_726Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
726 → 72E - Every
30 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x0010FA = 4346 → 4,346 km
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Previous trip distance CX30_PREV_TRIP_DST
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 km
- Unit
- km
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Total distance CX30_ODO_723Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
723 → 72B - Every
1 s - Testing for 2020 to 2021, 2023 to 2024, 2026
Example reply from a 2022 Mazda CX-30.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x0126DB = 75483 → 75,483 km
Confirmed for 2022. In testing for 2020, 2024. Supported for 2025. Not supported for 2021, 2023, 2026.
Vehicle odometer CX30_PCM_VEH_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID F4A6 - Module
7E0 → 7E8 - Every
30 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
0x0000A9C5 = 43461 → = 4,346.1 km
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.