Mazda B-Series Pickup

Parameters

The Mazda B-Series Pickup has 155 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage BSERIES_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

0x88 = 136 → 13620+6 = 12.8 V

Confirmed for 2017. In testing for 1996 to 2010.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery age BSERIES_12V_AGEConfirmed

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×24
Range
0 to 1572840 h
Unit
h

0x0000 = 0 → 0×24 = 0 h

Confirmed for 2017. In testing for 1996 to 2010.

12V battery state of charge BSERIES_12V_SOCConfirmed

  • Service 22DID 4028
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x4B = 75 → 75 %

Confirmed for 2017. In testing for 1996 to 2010.

12V battery temperature BSERIES_12V_TConfirmed

  • Service 22DID 4029
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 100 °C
Unit
°C

0x3C = 60 → 60−40 = 20 °C

Confirmed for 2017. In testing for 1996 to 2010.

12V battery voltage BSERIES_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

0x88 = 136 → 13620+6 = 12.8 V

Confirmed for 2017. In testing for 1996 to 2010.

Battery capacity too low for start/stop BSERIES_BAT_CAP_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2010, 2017.

Battery current too high for start/stop BSERIES_BAT_CURRENT_TOO_HIGH

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2010, 2017.

Battery current, predicted BSERIES_BAT_CURRENT

  • Service 22DID 4209
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val4
Range
-2097152 to 2097151.75 A
Unit
A

In testing for 1996 to 2010, 2017.

Battery percentage, state of charge BSERIES_BAT_PERCENTAGE_ST

  • Service 22DID 4028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1996 to 2010, 2017.

Battery quiescent current, low range BSERIES_BAT_QUIESCENT

  • Service 22DID 4025
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 mA
Unit
mA

In testing for 1996 to 2010, 2017.

Battery refresh cycle in progress for start/stop BSERIES_BAT_REFRESH_CYCLE

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2010, 2017.

Battery state detection status BSERIES_BAT_ST_DETECTION

  • Service 22DID 420A
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2010, 2017.

Battery state of charge too low for start/stop BSERIES_BAT_ST_CHG_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2010, 2017.

Battery temperature too low for auto stop BSERIES_BAT_T_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2010, 2017.

Battery voltage BSERIES_BAT_V

  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.9375 V
Unit
V

In testing for 1996 to 2010, 2017.

Battery voltage too low for auto restart BSERIES_BAT_V_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2010, 2017.

Battery voltage too low for cold cranking capability BSERIES_BAT_V_TOO_LOW_COLD

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2010, 2017.

Battery voltage too low for start/stop BSERIES_BAT_V_TOO_LOW_START

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2010, 2017.

Charge air cooler temperature BSERIES_CHG_AIR_COOLER_T

  • Service 22DID 0508
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8
Range
0 to 524280
Unit
Raw value

In testing for 1996 to 2010, 2017.

Charge air temperature BSERIES_CHG_AIR_T

  • Service 22DID 051C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2010, 2017.

Commanded generator voltage BSERIES_CMD_GEN_V

  • Service 22DID 0304
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000488
Range
0 to 16 V
Unit
V

In testing for 1996 to 2010, 2017.

Normalized cumulative charge when ignition is on BSERIES_NORM_CUM_CHG_IGN_ON

  • Service 22DID 401E
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 1996 to 2010, 2017.

Normalized cumulative discharge from battery with engine off BSERIES_NORM_CUM_DCHG_BAT_OFF

  • Service 22DID 4026
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 1996 to 2010, 2017.

Normalized cumulative discharge from battery with engine on BSERIES_NORM_CUM_DCHG_BAT_ON

  • Service 22DID 4021
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 1996 to 2010, 2017.

Second battery current BSERIES_VEH_BAT_B_CURRENT

  • Service 22DID 423C
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.96 A
Unit
A

In testing for 1996 to 2010, 2017.

Second battery voltage BSERIES_VEH_BAT_B_V

  • Service 22DID 41E8
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
6 to 18.75 V
Unit
V

In testing for 1996 to 2010, 2017.

Climate

A/C compressor pressure BSERIES_AC_PConfirmed

  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×245251845473
Range
0 to 1000 psi
Unit
psi

0x0223 = 547 → 547×245251845473 = 158.671296 psi

Confirmed for 2017. In testing for 1996 to 2010.

A/C compressor pressure sensor voltage BSERIES_AC_P_SENS_VConfirmed

  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

0x0609 = 1545 → 15451024 = 1.508789 V

Confirmed for 2017. In testing for 1996 to 2010.

A/C compressor, state BSERIES_AC_STATEConfirmed

  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

0x00 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

Ambient temperature sensor voltage BSERIES_AAT_VConfirmed

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2017. In testing for 1996 to 2010.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017.

Brake hydraulic pressure, raw count BSERIES_BRK_FL_PConfirmed

  • Service 22DID 2B0D
  • Module760 → 768
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

Parking brake state BSERIES_PARKING_BRAKEConfirmed

  • Service 22DID 2B00
  • Module760 → 768
  • Every3 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

Doors

Driver door ajar BSERIES_DRIVER_DOOR_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

Hood ajar? BSERIES_HOOD_OPENConfirmed

  • Service 22DID C154
  • Module726 → 72E
  • Every3 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

Lock status BSERIES_CENTRAL_LOCK_STATUSConfirmed

  • Service 22DID C259
  • Module726 → 72E
  • Every2 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x00 = 0 → UNLOCKED

States
Raw valueStateMeaning
0UNLOCKEDUnlocked
2LOCKEDLocked

Confirmed for 2017. In testing for 1996 to 2010.

Passenger door ajar? BSERIES_PASSENGER_DOOR_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

Rear left door ajar? BSERIES_RLD_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

Rear right door ajar? BSERIES_RRD_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

Trunk ajar? BSERIES_TRUNK_OPENConfirmed

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

DTCs

Number of DTCs BSERIES_DTC_CNTDConfirmed

  • Service 22DID 0202
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

Engine

Air conditioning pressure BSERIES_AC_P_7E0

  • Service 22DID FD18
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.156863
Range
0 to 3100 kPa
Unit
kPa

In testing for 1996 to 2010, 2017.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2017.

Alternator current output BSERIES_ALTERNATOR_CURRENT

  • Service 22DID D113
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 A
Unit
A

In testing for 1996 to 2010, 2017.

APP sensor 1 voltage BSERIES_APP1_VConfirmed

  • Service 22DID 0914
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x0302 = 770 → 7701000 = 0.77 V

Confirmed for 2017. In testing for 1996 to 2010.

APP sensor 2 voltage BSERIES_APP2_VConfirmed

  • Service 22DID 0915
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x018B = 395 → 3951000 = 0.395 V

Confirmed for 2017. In testing for 1996 to 2010.

Barometric pressure BSERIES_BAROMETRIC_P

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×33863980000
Range
0 to 1079.4118 kPa
Unit
kPa

In testing for 1996 to 2010, 2017.

Barometric pressure sensor voltage BSERIES_BARO_VConfirmed

  • Service 22DID 035A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2017. In testing for 1996 to 2010.

Battery current BSERIES_BAT_CURRENT_726

  • Service 22DID 4090
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−511.7
Range
-511.7 to 3584.2375 A
Unit
A

In testing for 1996 to 2010, 2017.

Boost BSERIES_BOOST

  • Service 22DID 1440
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 psi
Unit
psi

In testing for 1996 to 2010, 2017.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017.

Catalyst temperature BSERIES_CAT_TEMPConfirmed

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x03FD = 1021 → 102110−40 = 62.1 °C

Confirmed for 2017. In testing for 1996 to 2010.

Cylinder 1 misfire count BSERIES_MIS_CNT_1

  • Service 22DID 160E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2010, 2017.

Cylinder 2 misfire count BSERIES_MIS_CNT_2

  • Service 22DID 160F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2010, 2017.

Cylinder 3 misfire count BSERIES_MIS_CNT_3

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2010, 2017.

Cylinder 4 misfire count BSERIES_MIS_CNT_4

  • Service 22DID 1611
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2010, 2017.

Cylinder 5 misfire count BSERIES_MIS_CNT_5

  • Service 22DID 1612
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2010, 2017.

Cylinder 6 misfire count BSERIES_MIS_CNT_6

  • Service 22DID 1613
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2010, 2017.

Cylinder 7 misfire count BSERIES_MIS_CNT_7

  • Service 22DID 1614
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2010, 2017.

Cylinder 8 misfire count BSERIES_MIS_CNT_8

  • Service 22DID 1615
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2010, 2017.

Cylinder head temperature BSERIES_CYL_HEAD_T

  • Service 22DID 051D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2010, 2017.

Cylinder head temperature BSERIES_CYL_HEAD_T_7E0

  • Service 22DID 1624
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 1996 to 2010, 2017.

Cylinder head temperature, alternate BSERIES_CYL_HEAD_T_ALT

  • Service 22DID 1685
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2811000
Range
0 to 18415 °F
Unit
°F

In testing for 1996 to 2010, 2017.

Distance with MIL BSERIES_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2017. In testing for 1996 to 2010.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017.

Engine load BSERIES_ENG_LOAD_PCTConfirmed

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x33 = 51 → 51×100255 = 20 %

Confirmed for 2017. In testing for 1996 to 2010.

Engine oil pressure - desired BSERIES_EOP_DES

  • Service 22DID 05EF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 1996 to 2010, 2017.

Engine oil temperature BSERIES_EOTConfirmed

  • Service 22DID 1310
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

0x1900 = 6400 → 6400100−40 = 24 °C

Confirmed for 2017. In testing for 1996 to 2010.

Engine oil temperature BSERIES_EOT_7DFConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID F45C
  • Module7DF
  • Every30 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x42 = 66 → 66−40 = 26 °C

Confirmed for 2017. In testing for 1996 to 2010.

Engine oil temperature EOTSAE J1979Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 01PID 5C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017.

Engine run time BSERIES_RUN_TIMEConfirmed

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x003E = 62 → 62 s

Confirmed for 2017. In testing for 1996 to 2010.

Engine speed BSERIES_RPMConfirmed

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0C7B = 3195 → 31954 = 798.75 rpm

Confirmed for 2017. In testing for 1996 to 2010.

Exhaust gas recirculation BSERIES_EGR

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1996 to 2010, 2017.

Exhaust gas recirculation duty cycle BSERIES_EGR_DUTY

  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1996 to 2010, 2017.

Exhaust gas recirculation open BSERIES_EGR_OPEN

  • Service 22DID 052E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1996 to 2010, 2017.

Exhaust gas recirculation open BSERIES_EGR_OPEN_MMConfirmed

Monitors the physical position of the EGR valve, which controls the amount of exhaust gas being recirculated back into the engine's intake system.

  • Service 22DID 0306
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 mm
Unit
mm

0x0D04 = 3332 → 3332100 = 33.32 mm

Confirmed for 2017. In testing for 1996 to 2010.

Exhaust gas recirculation open BSERIES_EGR_OPEN_PERCConfirmed

  • Service 22DID 03FB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x53 = 83 → 83×100255 = 32.54902 %

Confirmed for 2017. In testing for 1996 to 2010.

Exhaust gas recirculation temperature BSERIES_EGR_T

  • Service 22DID 0543
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2010, 2017.

Exhaust gas temperature 1 BSERIES_EXH_GAS_T_1

  • Service 22DID 03F4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 1996 to 2010, 2017.

Exhaust gas temperature 2 BSERIES_EXH_GAS_T_2

  • Service 22DID 03F5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 1996 to 2010, 2017.

Fuel pump pulse width, bank 2 BSERIES_FUEL_PMP_WIDTH_BANK_2

  • Service 22DID 1142
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Number

In testing for 1996 to 2010, 2017.

Fuel rail pressure, desired BSERIES_HPFP_DESConfirmed

  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

0x0D57 = 3415 → 3415×10 = 34,150 kPa

Confirmed for 2017. In testing for 1996 to 2010.

Fuel rail sensor voltage, high pressure BSERIES_HPFP_VConfirmed

  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2017. In testing for 1996 to 2010.

Generator control BSERIES_GEN_CTRL

  • Service 22DID 0378
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 1996 to 2010, 2017.

Generator current BSERIES_GEN_CURRENT

  • Service 22DID 04F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78150000
Range
-511.8361 to 511.8205 A
Unit
A

In testing for 1996 to 2010, 2017.

Idle speed BSERIES_IDLEConfirmed

  • Service 22DID 096E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0C80 = 3200 → 32004 = 800 rpm

Confirmed for 2017. In testing for 1996 to 2010.

In car temperature BSERIES_CAR_T

  • Service 22DID DD04
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.875 °C
Unit
°C

In testing for 1996 to 2010, 2017.

Injector impulse width BSERIES_INJ_IMPULSE_WIDTH

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000022
Range
0 to 0.05 s
Unit
s

In testing for 1996 to 2010, 2017.

Intake air temperature 2 BSERIES_IAT_2

  • Service 22DID 16A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×59−17.777778
Range
-17.77 to 36390 °C
Unit
°C

In testing for 1996 to 2010, 2017.

Intake temperature sensor voltage BSERIES_IAT_SENS_VConfirmed

  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

0x01D8 = 472 → 472×51023 = 2.30694 V

Confirmed for 2017. In testing for 1996 to 2010.

Intake temperature, alternate BSERIES_IAT_ALT2Confirmed

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x42 = 66 → 66−40 = 26 °C

Confirmed for 2017. In testing for 1996 to 2010.

Manifold absolute pressure, high resolution BSERIES_MAP_HIRES

  • Service 22DID 0370
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 kPa
Unit
kPa

In testing for 1996 to 2010, 2017.

Manifold pressure BSERIES_MAPConfirmed

  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000068947
Range
0 to 36 psi
Unit
psi

0x66 = 102 → 102×1000068947 = 14.793972 psi

Confirmed for 2017. In testing for 1996 to 2010.

Manifold temperature BSERIES_MCTConfirmed

  • Service 22DID 03CA
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 148.889 °C
Unit
°C

0x3B = 59 → 59 °C

Confirmed for 2017. In testing for 1996 to 2010.

Navigation altitude BSERIES_SYNC_GPS_ALTITUDE

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2010, 2017.

Navigation heading BSERIES_SYNC_GPS_HEADING

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 1996 to 2010, 2017.

Sump oil temperature measured BSERIES_SUMP_OIL_T_MEAS

  • Service 22DID 03F3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2010, 2017.

Throttle inlet pressure sensor voltage BSERIES_TIP_VConfirmed

  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51024
Range
0 to 5 V
Unit
V

Confirmed for 2017. In testing for 1996 to 2010.

Throttle position 1 voltage BSERIES_TP1_VConfirmed

  • Service 22DID 0917
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x0122 = 290 → 2901000 = 0.29 V

Confirmed for 2017. In testing for 1996 to 2010.

Time since last oil change BSERIES_TIME_SINCE_OIL

  • Service 22DID 053F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20013107
Range
0 to 1000
Unit
Raw value

In testing for 1996 to 2010, 2017.

Torque converter slip BSERIES_TQ_CONV_SLIP

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.638538424
Range
0 to 39996.0104 rpm
Unit
rpm

In testing for 1996 to 2010, 2017.

Torque into torque converter BSERIES_TQ_INTO_TQ_CONV

  • Service 22DID 09CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.35581795
Range
0 to 48336.1353 N·m
Unit
N·m

In testing for 1996 to 2010, 2017.

Torque into torque converter BSERIES_TQ_INTO_TQ_CONV_7E0

  • Service 22DID 163A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 1996 to 2010, 2017.

Total misfire count BSERIES_TOT_MIS_CNT

  • Service 22DID 1616
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2010, 2017.

Transfer case fluid temperature BSERIES_TRANSFER_CASE_FLUID_T

  • Service 22DID 070D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °C
Unit
°C

In testing for 1996 to 2010, 2017.

Transmission fluid temperature, variant 1 BSERIES_ATF_T_VAR_1

  • Service 22DID 1674
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 °F
Unit
°F

In testing for 1996 to 2010, 2017.

Transmission fluid temperature, variant 6 BSERIES_ATF_T_VAR_6

  • Service 22DID 092C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 1996 to 2010, 2017.

Turbo boost BSERIES_TURBO_BOOST

  • Service 22DID 09DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 1996 to 2010, 2017.

Turbo inlet pressure BSERIES_TURBO_INLET_P

  • Service 22DID 05BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 1996 to 2010, 2017.

Variable geometry turbocharger open BSERIES_VGT_OPENConfirmed

  • Service 22DID 050F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 mm
Unit
mm

0xC7 = 199 → 199×100255 = 78.039216 mm

Confirmed for 2017. In testing for 1996 to 2010.

Variable geometry turbocharger open BSERIES_VGT_OPEN_PERCConfirmed

Measures the position of the vanes in the Variable Geometry Turbocharger (VGT) and reports this position as a percentage value.

  • Service 22DID 03DF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

0xC88A = 51338 → 51338×10065535 = 78.336767 %

Confirmed for 2017. In testing for 1996 to 2010.

Wastegate control BSERIES_WASTEGATE_CTRL

  • Service 22DID 16E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×76350000
Range
0 to 100 %
Unit
%

In testing for 1996 to 2010, 2017.

Fuel

Air/fuel ratio BSERIES_AIR_FUEL_RAT

  • Service 22DID F434
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000446787
Range
0 to 29.2801
Unit
Number

In testing for 1996 to 2010, 2017.

Engine fuel rate BSERIES_ENG_FUEL_RATE

  • Service 22DID F45E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L
Unit
L

In testing for 1996 to 2010, 2017.

Fuel correction, cylinder 1 BSERIES_FUEL_CORR_CYL_1

  • Service 22DID 098A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 1996 to 2010, 2017.

Fuel correction, cylinder 2 BSERIES_FUEL_CORR_CYL_2

  • Service 22DID 098B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 1996 to 2010, 2017.

Fuel correction, cylinder 3 BSERIES_FUEL_CORR_CYL_3

  • Service 22DID 098C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 1996 to 2010, 2017.

Fuel correction, cylinder 4 BSERIES_FUEL_CORR_CYL_4

  • Service 22DID 098D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 1996 to 2010, 2017.

Fuel correction, cylinder 5 BSERIES_FUEL_CORR_CYL_5

  • Service 22DID 11D3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 1996 to 2010, 2017.

Fuel correction, cylinder 6 BSERIES_FUEL_CORR_CYL_6

  • Service 22DID 048F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 1996 to 2010, 2017.

Fuel injection impulse width BSERIES_FUEL_INJ_IMPULSE

  • Service 22DID 168B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val125000
Range
0 to 0.1 s
Unit
s

In testing for 1996 to 2010, 2017.

Fuel level BSERIES_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x5C = 92 → 92×100255 = 36.078431 %

Confirmed for 2017. In testing for 1996 to 2010.

Fuel level BSERIES_FLI_7E0

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 16C1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518509
Range
0 to 200 %
Unit
%

In testing for 1996 to 2010, 2017.

Fuel pump duty cycle BSERIES_FUEL_PMP_DUTY

  • Service 22DID 1672
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532
Range
0 to 199.2187 %
Unit
%

In testing for 1996 to 2010, 2017.

Fuel tank pressure BSERIES_FUEL_TANK_P

  • Service 22DID 1639
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val6.901311249
Range
0 to 9496.0214 psi
Unit
psi

In testing for 1996 to 2010, 2017.

Fuel temperature BSERIES_FUEL_TConfirmed

  • Service 22DID 0522
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x40 = 64 → 64−40 = 24 °C

Confirmed for 2017. In testing for 1996 to 2010.

Lights

Exterior lighting state BSERIES_EXTERIOR_LIGHT_STATEConfirmed

  • Service 22DID 407E
  • Module726 → 72E
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bit 0 of the reply.

Unit
Named states

0b0 = 0 → 0

States
Raw valueState
00
2161

Confirmed for 2017. In testing for 1996 to 2010.

High beam status BSERIES_HIGHBEAM_STATUSConfirmed

  • Service 22DID 7151
  • Module726 → 72E
  • Every4 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2
Unit
Off or on

0x0000 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

Movement

Accelerator pedal position BSERIES_ACCEL_PEDAL_POS

  • Service 22DID 09D4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 1996 to 2010, 2017.

Fan speed sensor BSERIES_FAN_SPD_SENS

  • Service 22DID 099F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 1996 to 2010, 2017.

Fan speed, desired BSERIES_FAN_SPD_DES

  • Service 22DID 03B9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4013107
Range
0 to 100 %
Unit
%

In testing for 1996 to 2010, 2017.

Front left wheel speed BSERIES_FL_VSSConfirmed

  • Service 22DID 2B07
  • Module760 → 768
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2017. In testing for 1996 to 2010.

Front right wheel speed BSERIES_FR_VSSConfirmed

  • Service 22DID 2B06
  • Module760 → 768
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2017. In testing for 1996 to 2010.

Lateral acceleration BSERIES_LAT_GConfirmed

  • Service 22DID 2B11
  • Module760 → 768
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-1 to 1
Unit
Number

0x0016 = 22 → 2250 = 0.44

Confirmed for 2017. In testing for 1996 to 2010.

Lateral angle, raw count BSERIES_LAT_ANGConfirmed

  • Service 22DID 2B0C
  • Module760 → 768
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

0x0000 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

Navigation speed BSERIES_SYNC_GPS_SPD

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×185
Range
0 to 235926 km/h
Unit
km/h

In testing for 1996 to 2010, 2017.

Rear left wheel speed BSERIES_RL_VSSConfirmed

  • Service 22DID 2B09
  • Module760 → 768
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2017. In testing for 1996 to 2010.

Rear right wheel speed BSERIES_RR_VSSConfirmed

  • Service 22DID 2B08
  • Module760 → 768
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2017. In testing for 1996 to 2010.

Vehicle speed BSERIES_VSSConfirmed

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2017. In testing for 1996 to 2010.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2017.

Vehicle speed, high resolution BSERIES_VSS_HDConfirmed

  • Service 22DID 1505
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 200 km/h
Unit
km/h

0x0000 = 0 → 0128 = 0 km/h

Confirmed for 2017. In testing for 1996 to 2010.

Tires

Tire temperature BSERIES_TYRE_T

  • Service 22DID 280B
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2010, 2017.

Transmission

All-wheel drive clutch diagnostic signal BSERIES_AWD_CLU_DIAGNOSTIC

  • Service 22DID 1E62
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1996 to 2010, 2017.

All-wheel drive clutch, commanded control signal BSERIES_AWD_CLU_CMD_CTRL_SIG

  • Service 22DID 1E63
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 1996 to 2010, 2017.

Converter speed ratio BSERIES_CONV_SPD_RAT

  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×582
Range
0 to 3996.0365
Unit
Number

In testing for 1996 to 2010, 2017.

Gear, engaged BSERIES_GEAR_ENGConfirmed

  • Service 22DID 1E1F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 1996 to 2010.

Torque converter line pressure BSERIES_TQ_CONV_LINE_P

  • Service 22DID 11C0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1723695000
Range
0 to 8790.819 kPa
Unit
kPa

In testing for 1996 to 2010, 2017.

Transmission gear BSERIES_TRANS_GEAR

  • Service 22DID 11B3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

In testing for 1996 to 2010, 2017.

Transmission gear ratio BSERIES_TRANS_GEAR_RAT

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×15.7480315
Range
0 to 4015.748
Unit
Number

In testing for 1996 to 2010, 2017.

Transmission output shaft speed BSERIES_TRANS_OUTPUT_SHFT

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638.375 rpm
Unit
rpm

In testing for 1996 to 2010, 2017.

Transmission range code BSERIES_GEAR_SHFT_7DFConfirmed

Selected range. Neutral, reverse and park are mapped; the code driving reports (43) is not yet.

  • Service 22DID 1E23
  • Module7DF
  • Every30 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x46 = 70 → 70

Confirmed for 2017. In testing for 1996 to 2010.

Transmission temperature BSERIES_TRANS_T_V6Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E1C
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-500 to 500 °C
Unit
°C

0x01BD = 445 → 44516 = 27.8125 °C

Confirmed for 2017. In testing for 1996 to 2010.

Trips

Odometer BSERIES_ODO_720

  • Service 22DID 6180
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 1996 to 2010, 2017.

Odometer BSERIES_ODO_7E0Confirmed

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x0374A1 = 226465 → 226,465 km

Confirmed for 2017. In testing for 1996 to 2010.

Odometer, instrument panel BSERIES_ODO_726Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726 → 72E
  • Every30 s
  • Testing for 1996 to 2010

Example reply from a 2017 Mazda B-Series Pickup.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x0374A1 = 226465 → 226,465 km

Confirmed for 2017. In testing for 1996 to 2010.

Total distance, lifetime BSERIES_TOT_DIST_LIFETIME

  • Service 22DID F817
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 km
Unit
km

In testing for 1996 to 2010, 2017.