Lincoln Corsair

Parameters

The Lincoln Corsair has 528 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery age LINCOLN_12V_AGE

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×24
Range
0 to 1572840 h
Unit
h

In testing for 2020 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery age LINCOLN_12V_AGE

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×24
Range
0 to 1572840 h
Unit
h

In testing for 2020 to 2026.

12V battery current LINCOLN_VEH_BAT_CURRENT

  • Service 22DID 402B
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−127
Range
-127 to 128 A
Unit
A

In testing for 2020 to 2026.

12V battery voltage LINCOLN_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

In testing for 2020 to 2026.

Aux 12V battery control mode LINCOLN_AUX_12V_BAT_CTRL

  • Service 22DID 40D1
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Average battery module voltage LINCOLN_AVG_BAT_MODULE_V

  • Service 22DID 4841
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2026.

Battery age LINCOLN_BATT_AGE

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1825
Unit
Number

In testing for 2020 to 2026.

Battery capacity LINCOLN_BAT_CAP

  • Service 22DID 485C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 Ah
Unit
Ah

In testing for 2020 to 2026.

Battery capacity too low for start/stop LINCOLN_BAT_CAP_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Battery charge LINCOLN_BATT_SOC

  • Service 22DID 4028
  • Module726 → 72E
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Battery current too high for start/stop LINCOLN_BAT_CURRENT_TOO_HIGH

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Battery current, predicted LINCOLN_BAT_CURRENT

  • Service 22DID 4209
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val4
Range
-2097152 to 2097151.75 A
Unit
A

In testing for 2020 to 2026.

Battery discharge power limit LINCOLN_BAT_DCHG_POWER_LIM

  • Service 22DID 4852
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kW
Unit
kW

In testing for 2020 to 2026.

Battery pack lifetime charge out, throughput LINCOLN_BAT_PACK_LIFETIME

  • Service 22DID 485D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 Ah
Unit
Ah

In testing for 2020 to 2026.

Battery percentage, state of charge LINCOLN_BAT_PERCENTAGE_ST

  • Service 22DID 4028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

Battery quiescent current, low range LINCOLN_BAT_QUIESCENT

  • Service 22DID 4025
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 mA
Unit
mA

In testing for 2020 to 2026.

Battery refresh cycle in progress for start/stop LINCOLN_BAT_REFRESH_CYCLE

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Battery state detection status LINCOLN_BAT_ST_DETECTION

  • Service 22DID 420A
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Battery state of charge too low for start/stop LINCOLN_BAT_ST_CHG_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Battery temperature LINCOLN_BATT_TEMP

  • Service 22DID 4029
  • Module726 → 72E
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 100 °C
Unit
°C

In testing for 2020 to 2026.

Battery temperature too low for auto stop LINCOLN_BAT_T_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Battery voltage LINCOLN_BAT_V

  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.9375 V
Unit
V

In testing for 2020 to 2026.

Battery voltage LINCOLN_BAT_V_7E0

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2026.

Battery voltage too low for auto restart LINCOLN_BAT_V_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Battery voltage too low for cold cranking capability LINCOLN_BAT_V_TOO_LOW_COLD

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Battery voltage too low for start/stop LINCOLN_BAT_V_TOO_LOW_START

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Charge air cooler temperature LINCOLN_CHG_AIR_COOLER_T

  • Service 22DID 0508
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8
Range
0 to 524280
Unit
Raw value

In testing for 2020 to 2026.

Charge air temperature LINCOLN_CHG_AIR_T

  • Service 22DID 051C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Charger digital mode LINCOLN_EVSE_DIGITAL_MODE

  • Service 22DID 48B7
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1DC_E_MINUSDC E-
2DC_MINUS_PDC -P
3DC_EPDC EP
4AC_E_MINUSAC E-
5AC_MINUS_PAC -P
6AC_EPAC EP
7RESETReset
8OFFOff
9ESTABLISHEstablish
10FAULTFault

In testing for 2020 to 2026.

Charger input power available LINCOLN_CHARGER_INPUT_POWER

  • Service 22DID 484E
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 kW
Unit
kW

In testing for 2020 to 2026.

Charger output voltage LINCOLN_CHARGER_OUTPUT_V

  • Service 22DID 484A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2020 to 2026.

Charger type LINCOLN_EVSE_TYPE

  • Service 22DID 4851
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1LEVEL_1Level 1
2LEVEL_2Level 2
3DC
4BASICBasic
5HIGH_LEVELHigh Level
6BASIC_ACBasic AC
7HIGH_LEVEL_ACHigh Level AC
8HIGH_LEVEL_DCHigh Level DC
10NO_COMMNo communication
11FAULTFault
12HANDSHAKE_ENDHandshake end

In testing for 2020 to 2026.

Charging state LINCOLN_CHRG_STATE

Pelican can show this parameter as the charging state.

  • Service 22DID 484F
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_READYNot ready
1READYReady
2FAULTFault
3WAITWait Check
4PRE_CONDPre-condition
5CHARGINGCharging
6DONEDone
7EXTExternal Charger
8INITInitializing

In testing for 2020 to 2026.

Commanded generator voltage LINCOLN_CMD_GEN_V

  • Service 22DID 0304
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000488
Range
0 to 16 V
Unit
V

In testing for 2020 to 2026.

Contactor voltage negative LINCOLN_CONTACTOR_V_NEG

  • Service 22DID 4806
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2020 to 2026.

Contactor voltage negative LINCOLN_CONTACTOR_V_NEGATIVE

  • Service 22DID 4806
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.34 V
Unit
V

In testing for 2020 to 2026.

Contactor voltage positive LINCOLN_CONTACTOR_V_POS

  • Service 22DID 4805
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 V
Unit
V

In testing for 2020 to 2026.

Contactor voltage positive LINCOLN_CONTACTOR_V_POSITIVE

  • Service 22DID 4805
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.34 V
Unit
V

In testing for 2020 to 2026.

DC charger status LINCOLN_DC_CHARGER_STAT

  • Service 22DID 489E
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

DC charging system contactor voltage LINCOLN_DC_CHG_SYSTEM_V

  • Service 22DID 48AF
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2020 to 2026.

DC-DC converter LINCOLN_DCDC_ENABLED

  • Service 22DID 483D
  • Module746 → 74E
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

High voltage AC charger coupler temperature LINCOLN_HIGH_V_AC_CHARGER_COUPLER_T

  • Service 22DID D117
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

In testing for 2020 to 2026.

High voltage AC charger coupler temperature LINCOLN_HIGH_V_AC_CHARGER_T

  • Service 22DID 4888
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

In testing for 2020 to 2026.

High voltage battery intake air temperature LINCOLN_HVBAT_IAT

  • Service 22DID 000F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−39.8
Range
-39.8 to 419 °F
Unit
°F

In testing for 2020 to 2026.

High voltage charger current, requested LINCOLN_HIGH_V_CHARGER

  • Service 22DID 4842
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2020 to 2026.

High voltage charger input power available, raw count LINCOLN_HIGH_V_CHARGER_INPUT

  • Service 22DID 484E
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

High voltage charger output current measured LINCOLN_HIGH_V_CHARGER_OUTPUT

  • Service 22DID 4850
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2020 to 2026.

High voltage charger output reduction temperature LINCOLN_HIGH_V_CHARGER_T

  • Service 22DID 48A5
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

High voltage charger output voltage, raw count LINCOLN_HIGH_V_CHARGER_V

  • Service 22DID 484A
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

High voltage charger pilot voltage LINCOLN_HIGH_V_CHARGER_PILOT_V

  • Service 22DID 48B6
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2020 to 2026.

High voltage charger pilot voltage, raw count LINCOLN_HIGH_V_CHARGER_PILOT_V_RAW

  • Service 22DID 48BC
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

High voltage charger status LINCOLN_HIGH_V_CHARGER_STAT

  • Service 22DID 484D
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

High voltage charger status LINCOLN_HIGH_V_CHARGER_STAT_7E2

  • Service 22DID 484F
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

High voltage charger voltage, requested LINCOLN_HIGH_V_CHARGER_V_REQ

  • Service 22DID 4844
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 V
Unit
V

In testing for 2020 to 2026.

High voltage charger, maximum power LINCOLN_HIGH_V_CHARGER_MAX

  • Service 22DID 48C4
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kW
Unit
kW

In testing for 2020 to 2026.

High voltage DC charger coupler temperature LINCOLN_HIGH_V_DC_CHARGER_T

  • Service 22DID D00C
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

In testing for 2020 to 2026.

High voltage DC charger coupler temperature 1 LINCOLN_HIGH_V_DC_CHARGER_T_1

  • Service 22DID 4897
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

In testing for 2020 to 2026.

High voltage DC charger coupler temperature 3 LINCOLN_HIGH_V_DC_CHARGER_T_3

  • Service 22DID 48A4
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

In testing for 2020 to 2026.

High voltage DC charger status LINCOLN_HIGH_V_DC_CHARGER

  • Service 22DID 489E
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

High voltage DC charger, maximum voltage LINCOLN_HIGH_V_DC_CHARGER_MAX_V

  • Service 22DID 489D
  • Module6F5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2020 to 2026.

High voltage DC charger, maximum, current LINCOLN_HIGH_V_DC_CHARGER_MAX

  • Service 22DID 4899
  • Module6F5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2020 to 2026.

High-voltage battery current LINCOLN_HVB_CURRENT

  • Service 22DID 48F9
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2020 to 2026.

High-voltage battery voltage, raw count LINCOLN_HVB_V_RAW_CNT

  • Service 22DID 480D
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

HV AC charger coupler temperature LINCOLN_AC_CHG_COUPLER_T

  • Service 22DID 4888
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

HV AC charger input current LINCOLN_AC_CHG_IN_A

  • Service 22DID 485F
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 A
Unit
A

In testing for 2020 to 2026.

HV AC charger input frequency LINCOLN_AC_CHG_IN_FREQ

  • Service 22DID 4860
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 90 Hz
Unit
Hz

In testing for 2020 to 2026.

HV AC charger input voltage LINCOLN_AC_CHG_IN_V

  • Service 22DID 485E
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 V
Unit
V

In testing for 2020 to 2026.

HV battery age LINCOLN_HVBAT_AGE

  • Service 22DID 4810
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×720200
Range
0 to 235926 h
Unit
h

In testing for 2020 to 2026.

HV battery average module voltage LINCOLN_HVBAT_AVG_MOD_V

  • Service 22DID 4841
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 50 V
Unit
V

In testing for 2020 to 2026.

HV battery charge LINCOLN_HVBAT_SOC

High resolution state of charge.

Pelican can show this parameter as the state of charge.

  • Service 22DID 4801
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

HV battery charge current requested LINCOLN_HVBAT_CCR

  • Service 22DID 4842
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 600 A
Unit
A

In testing for 2020 to 2026.

HV battery charge power limit LINCOLN_HVBAT_CHG_PWR_LIM

  • Service 22DID 48FB
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 300 kW
Unit
kW

In testing for 2020 to 2026.

HV battery charge voltage requested LINCOLN_HVBAT_CVR

  • Service 22DID 4844
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 500 V
Unit
V

In testing for 2020 to 2026.

HV battery charge, displayed LINCOLN_HVBAT_SOC_DISP

The state of charge displayed on the vehicle's dashboard.

Pelican can show this parameter as the state of charge.

  • Service 22DID 4845
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

HV battery charging status LINCOLN_HVBAT_CHG_STATUS

  • Service 22DID 484D
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_READYNot ready
1WAITWait
2READYReady
3CHARGINGCharging
4DONEDone
5FAULTFault

In testing for 2020 to 2026.

HV battery coolant inlet temperature LINCOLN_HVBAT_COOLANT_INLET_T

  • Service 22DID 4846
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2026.

HV battery current LINCOLN_HVBAT_A

Pelican can show this parameter as the traction battery current.

  • Service 22DID 48F9
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-600 to 600 A
Unit
A

In testing for 2020 to 2026.

HV battery current high range LINCOLN_HVBAT_CHR_A

  • Service 22DID 4809
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 A
Unit
A

In testing for 2020 to 2026.

HV battery current, alternate LINCOLN_HVBAT_A_ALT

  • Service 22DID 480B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-300 to 300 A
Unit
A

In testing for 2020 to 2026.

HV battery energy LINCOLN_HVBAT_KWH

  • Service 22DID 4848
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131.07 kWh
Unit
kWh

In testing for 2020 to 2026.

HV battery maximum charge current LINCOLN_HVBAT_MAX_CHG_A

  • Service 22DID 48BC
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 A
Unit
A

In testing for 2020 to 2026.

HV battery minimum module voltage LINCOLN_HVBAT_MIN_MOD_V

  • Service 22DID 4840
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2020 to 2026.

HV battery modules voltage LINCOLN_HVBAT_MOD_V

  • Service 22DID 483F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2020 to 2026.

HV battery state of health LINCOLN_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID 490C
  • Module7E4 → 7EC
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

HV battery temperature LINCOLN_HVBAT_T

  • Service 22DID 4800
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2026.

HV battery temperature range, maximum LINCOLN_T_RANGE_MAX

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2026.

HV battery temperature range, minimum LINCOLN_T_RANGE_MIN

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2026.

HV battery temperature, average LINCOLN_HVBAT_T_AVG

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2026.

HV battery thermal operation mode LINCOLN_HVBAT_THERMAL_OP_MODE

  • Service 22DID 48E0
  • Module7E6 → 7EE
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1EQUALIZEEqualize
2COOLANT_FLOWCoolant flow
3COOLANT_FANCoolant fan
4COOLANT_MODERATECoolant moderate
5COOLANT_MAXCoolant maximum
15HEATHeat

In testing for 2020 to 2026.

HV battery voltage LINCOLN_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 480D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2020 to 2026.

HV charger input power available LINCOLN_CHG_PWR_AVAIL

  • Service 22DID 484E
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327.675 kW
Unit
kW

In testing for 2020 to 2026.

HV charger maximum power LINCOLN_CHG_MAX_PWR

  • Service 22DID 48C4
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

In testing for 2020 to 2026.

HV charger output current measured LINCOLN_CHG_OUT_A

  • Service 22DID 4850
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 600 A
Unit
A

In testing for 2020 to 2026.

HV charger output reduction temperature LINCOLN_CHG_OUT_REDUCT_T

  • Service 22DID 48A5
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

HV charger output voltage LINCOLN_CHG_OUT_V

  • Service 22DID 484A
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 600 V
Unit
V

In testing for 2020 to 2026.

HV charger pilot duty cycle LINCOLN_CHG_PILOT_DUTY

  • Service 22DID 4861
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

HV charger pilot voltage LINCOLN_CHG_PILOT_V

  • Service 22DID 48B6
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 15 V
Unit
V

In testing for 2020 to 2026.

HV charger proximity status LINCOLN_CHG_PROX_STATUS

  • Service 22DID 4862
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1ON_S3On S3
2ONOn
310A10 A
413A13 A
516A16 A
620A20 A
7FAULTFault
832A32 A
963A63 A
16DC
17OPENOpen
18SHORTShort
19SHORT_PWRShort to power
20OUT_OF_RANGEOut of range
21OPEN_CIRCUITOpen circuit

In testing for 2020 to 2026.

HV charger proximity voltage LINCOLN_CHG_PROX_V

  • Service 22DID 48A0
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2020 to 2026.

HV DC charger coupler temperature 1 LINCOLN_DC_CHG_COUPLER_T1

  • Service 22DID 4897
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

HV DC charger coupler temperature 3 LINCOLN_DC_CHG_COUPLER_T3

  • Service 22DID 48A4
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

HV DC charger maximum current LINCOLN_HVDC_CHG_MAX_C

  • Service 22DID 4899
  • Module6F5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 A
Unit
A

In testing for 2020 to 2026.

HV DC charger maximum voltage LINCOLN_HVDC_CHG_MAX_V

  • Service 22DID 489D
  • Module6F5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2020 to 2026.

HV DC charger status LINCOLN_DC_CHG_STATUS

  • Service 22DID 489E
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_READYNot ready
1INITInitialize
2READYReady
3WAIT_CHECKWait check
4PRE_CONDITIONPre-condition
5CHARGINGCharging
6DONEDone
8WAITWait
9NOT_CAPABLENot capable
10FAULTFault
11CHARGER_CHECKCharger check

In testing for 2020 to 2026.

HV negative leakage voltage LINCOLN_HV_NEG_LEAK_V

  • Service 22DID 4804
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2020 to 2026.

HV positive leakage voltage LINCOLN_HV_POS_LEAK_V

  • Service 22DID 4803
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2020 to 2026.

Hybrid battery pack remaining charge LINCOLN_HYBRID_BAT_PACK

  • Service 22DID F45B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Injection control pressure sensor voltage LINCOLN_ICP_V

  • Service 22DID 16AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Low voltage converter input current LINCOLN_DCDC_HV_A

  • Service 22DID 483A
  • Module746 → 74E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25 A
Unit
A

In testing for 2020 to 2026.

Low voltage converter output current LINCOLN_DCDC_LV_A

  • Service 22DID 4836
  • Module746 → 74E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2020 to 2026.

Maximum discharge power limit LINCOLN_MAX_DISCH_PWR_LIM

  • Service 22DID 4815
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25100
Range
0 to 63.75 kW
Unit
kW

In testing for 2020 to 2026.

Minimum battery module voltage LINCOLN_BATT_MIN_BATT_V

  • Service 22DID 4840
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2026.

Normalized cumulative charge when ignition is on LINCOLN_NORM_CUM_CHG_IGN_ON

  • Service 22DID 401E
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2020 to 2026.

Normalized cumulative discharge from battery with engine off LINCOLN_NORM_CUM_DCHG_BAT_OFF

  • Service 22DID 4026
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2020 to 2026.

Normalized cumulative discharge from battery with engine on LINCOLN_NORM_CUM_DCHG_BAT_ON

  • Service 22DID 4021
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2020 to 2026.

PF differential pressure feedback EGR sensor voltage LINCOLN_PF_DIFF_P_FEEDBACK_V

  • Service 22DID 03E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9771000000
Range
-32.01 to 32.01 V
Unit
V

In testing for 2020 to 2026.

Second battery current LINCOLN_VEH_BAT_B_CURRENT

  • Service 22DID 423C
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.96 A
Unit
A

In testing for 2020 to 2026.

Second battery voltage LINCOLN_VEH_BAT_B_V

  • Service 22DID 41E8
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
6 to 18.75 V
Unit
V

In testing for 2020 to 2026.

State of charge spread across battery modules LINCOLN_BATT_SOC_V2

  • Service 22DID 483E
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 %
Unit
%

In testing for 2020 to 2026.

Target/desired state of charge LINCOLN_TARGET_SOC

  • Service 22DID 05A1
  • Module7E4 → 7EC
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Temperature range LINCOLN_T_RANGE

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2026.

Temperature range average LINCOLN_T_RANGE_AVG

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2026.

Traction battery voltage, alternate LINCOLN_TRACTION_BAT_V_ALT

  • Service 22DID 490B
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 199 V
Unit
V

In testing for 2020 to 2026.

Vehicle battery voltage LINCOLN_VEH_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
6 to 18.75 V
Unit
V

In testing for 2020 to 2026.

Voltage spread across battery modules LINCOLN_BAT_V_VARIATION_BAT

  • Service 22DID 483F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2020 to 2026.

Climate

A/C compressor current LINCOLN_AC_COMP_A

  • Service 22DID 99AB
  • Module7C7
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10032767
Range
-100 to 100 A
Unit
A

In testing for 2020 to 2026.

A/C compressor pressure LINCOLN_AC_P

  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×245251845473
Range
0 to 1000 psi
Unit
psi

In testing for 2020 to 2026.

A/C compressor pressure sensor voltage LINCOLN_AC_P_SENS_V

  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

A/C compressor, state LINCOLN_AC_STATE

  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

A/C refrigerant pressure LINCOLN_PCM_A_C_REFRIG_P

  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 2020 to 2026.

Ambient temperature sensor voltage LINCOLN_AAT_V

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Ambient temperature, alternate LINCOLN_AAT_ALT

  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2020 to 2026.

Coolant heater operation mode LINCOLN_COOLANT_HTR_OP_MODE

  • Service 22DID 48DF
  • Module7E6 → 7EE
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1ONOn
2DEGRADEDDegraded
3SHUTDOWNShutdown
4SHORTShort
5NO_RESPONSENo response
6UNKNOWNUnknown
7STOPStop

In testing for 2020 to 2026.

Coolant heater power LINCOLN_COOLANT_HTR_PWR

  • Service 22DID 48DE
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 kW
Unit
kW

In testing for 2020 to 2026.

Exterior temperature LINCOLN_AAT

  • Service 22DID DD05
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Interior temperature LINCOLN_IAT

  • Service 22DID DD04
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Control

Anti-lock brake lateral acceleration LINCOLN_ABS_LATERAL_ACCEL

  • Service 22DID 3A51
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g
Unit
g

In testing for 2020 to 2026.

Anti-lock brake wheel speed 1 LINCOLN_ABS_WHL_SPD_1

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Anti-lock brake wheel speed 2 LINCOLN_ABS_WHL_SPD_2

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Anti-lock brake wheel speed 3 LINCOLN_ABS_WHL_SPD_3

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Anti-lock brake wheel speed 4 LINCOLN_ABS_WHL_SPD_4

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Brake booster pressure LINCOLN_BRAKE_BOOSTER_P

  • Service 22DID 2028
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 kPa
Unit
kPa

In testing for 2020 to 2026.

Brake hydraulic pressure, raw count LINCOLN_BRK_FL_P

  • Service 22DID 2B0D
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Foot brake LINCOLN_FOOT_BRAKE

  • Service 22DID 3B40
  • Module703 → 70B
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Parking brake state LINCOLN_PARKING_BRAKE

  • Service 22DID 2B00
  • Module760 → 768
  • Every3 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Steering wheel angle LINCOLN_STEER_ANGLE

Positive is rotated to the left, negative is rotated to the right.

  • Service 22DID 3201
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20−1638.4
Range
-1638 to 1638 °
Unit
°

In testing for 2020 to 2026.

Cruise control

Target vehicle speed LINCOLN_CC_TGT_VSS

The speed of the vehicle ahead of you.

  • Service 22DID A224
  • Module764
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×3.610
Range
-736 to 736 km/h
Unit
km/h

In testing for 2020 to 2026.

Doors

Driver door ajar LINCOLN_DRIVER_DOOR_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2020 to 2026.

Hood ajar? LINCOLN_HOOD_OPEN

  • Service 22DID C154
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2020 to 2026.

Lock status LINCOLN_CENTRAL_LOCK_STATUS

  • Service 22DID C259
  • Module726 → 72E
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNLOCKEDUnlocked
2LOCKEDLocked

In testing for 2020 to 2026.

Passenger door ajar? LINCOLN_PASSENGER_DOOR_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2020 to 2026.

Rear left door ajar? LINCOLN_RLD_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2020 to 2026.

Rear right door ajar? LINCOLN_RRD_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2020 to 2026.

Trunk ajar? LINCOLN_TRUNK_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2020 to 2026.

Drivetrain

Primary motor coil temperature LINCOLN_PRI_MOTOR_COIL_T

  • Service 22DID 481F
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 2020 to 2026.

Primary motor inverter temperature LINCOLN_PRI_MOTOR_INV_T

  • Service 22DID 4824
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 2020 to 2026.

Primary motor inverter voltage LINCOLN_PRI_MOTOR_INV_V

  • Service 22DID 481D
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-400 to 400 V
Unit
V

In testing for 2020 to 2026.

Primary motor speed LINCOLN_PRI_MOTOR_RPM

  • Service 22DID 1E2C
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-6000 to 12000 rpm
Unit
rpm

In testing for 2020 to 2026.

Primary motor torque LINCOLN_PRI_MOTOR_TQ

  • Service 22DID 481C
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-200 to 200 N·m
Unit
N·m

In testing for 2020 to 2026.

Secondary motor coil temperature LINCOLN_SEC_MOTOR_COIL_T

  • Service 22DID 4820
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 2020 to 2026.

Secondary motor inverter temperature LINCOLN_SEC_MOTOR_INV_T

  • Service 22DID 481E
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 2020 to 2026.

Secondary motor inverter voltage LINCOLN_SEC_MOTOR_INV_V

  • Service 22DID 4823
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-400 to 400 V
Unit
V

In testing for 2020 to 2026.

Secondary motor speed LINCOLN_SEC_MOTOR_RPM

  • Service 22DID 4821
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-6000 to 12000 rpm
Unit
rpm

In testing for 2020 to 2026.

Secondary motor torque LINCOLN_SEC_MOTOR_TQ

  • Service 22DID 481A
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-200 to 200 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine

Accelerator position LINCOLN_ACC_POS

  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Actual engine percent torque LINCOLN_PCM_ACT_ENG_PCT_TRQ

  • Service 22DID F462
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Actuator cam position corrected LINCOLN_ACTUATOR_CAM_POS

  • Service 22DID 017C
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 °
Unit
°

In testing for 2020 to 2026.

Actuator duty cycle output, commanded LINCOLN_ACTUATOR_DUTY_OUTPUT_CMD

  • Service 22DID 017F
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1953500000
Range
-127 to 127 %
Unit
%

In testing for 2020 to 2026.

Air conditioning pressure LINCOLN_AC_P_7E0

  • Service 22DID FD18
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.156863
Range
0 to 3100 kPa
Unit
kPa

In testing for 2020 to 2026.

Alternator 2 monitor LINCOLN_ALTERNATOR_2_MON

  • Service 22DID 0455
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2020 to 2026.

Alternator current output LINCOLN_ALTERNATOR_CURRENT

  • Service 22DID D113
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 A
Unit
A

In testing for 2020 to 2026.

Ambient air temperature LINCOLN_AAT_7E0

  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Barometric pressure LINCOLN_BARO

  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×61516963
Range
8 to 20 psi
Unit
psi

In testing for 2020 to 2026.

Barometric pressure LINCOLN_BAROMETRIC_P

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×33863980000
Range
0 to 1079.4118 kPa
Unit
kPa

In testing for 2020 to 2026.

Barometric pressure sensor voltage LINCOLN_BARO_V

  • Service 22DID 035A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Battery current LINCOLN_BAT_CURRENT_726

  • Service 22DID 4090
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−511.7
Range
-511.7 to 3584.2375 A
Unit
A

In testing for 2020 to 2026.

Boost LINCOLN_BOOST

  • Service 22DID 1440
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 psi
Unit
psi

In testing for 2020 to 2026.

Bypass valve LINCOLN_BPV_OPEN

  • Service 22DID 0427
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val255
Range
0 to 1
Unit
Number

In testing for 2020 to 2026.

Calculated soot in oil LINCOLN_CALC_SOOT_OIL

  • Service 22DID 0508
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val×8
Range
0 to 8
Unit
Off or on

In testing for 2020 to 2026.

Camshaft position error, exhaust LINCOLN_VCT_EXH_ERR

  • Service 22DID 031B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

In testing for 2020 to 2026.

Camshaft position error, intake LINCOLN_VCT_INT_ERR

  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

In testing for 2020 to 2026.

Camshaft position, exhaust actual LINCOLN_VCT_EXH_ACT

  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

In testing for 2020 to 2026.

Camshaft position, exhaust desired LINCOLN_VCT_EXH_DES

  • Service 22DID 03BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

In testing for 2020 to 2026.

Camshaft position, intake actual LINCOLN_VCT_INT_ACT

  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 0 °
Unit
°

In testing for 2020 to 2026.

Camshaft position, intake desired LINCOLN_VCT_INT_DES

  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

In testing for 2020 to 2026.

Camshaft solenoid duty cycle, exhaust LINCOLN_VCT_EXH_DUTY

  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Camshaft solenoid duty cycle, intake LINCOLN_VCT_INT_DUTY

  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Catalyst temperature LINCOLN_CAT_TEMP

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2020 to 2026.

Charge air temperature LINCOLN_CAT

  • Service 22DID 0461
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64−40
Range
-40 to 189 °C
Unit
°C

In testing for 2020 to 2026.

Charge air temperature 2 LINCOLN_CHG_AIR_T_2

  • Service 22DID 0461
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64−40
Range
-40 to 189 °C
Unit
°C

In testing for 2020 to 2026.

Charge air temperature sensor voltage LINCOLN_CAT_SENS_V

  • Service 22DID 0460
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Charging inhibit - requested LINCOLN_CHG_INHIBIT_REQ

  • Service 22DID 4878
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Charging station connection, raw count LINCOLN_EVSE_CHG_RAW_CNT

  • Service 22DID 4851
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Commanded generator duty LINCOLN_CMD_GEN_DUTY

  • Service 22DID 16E8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Coolant heater power LINCOLN_CLT_HEATER_POWER

  • Service 22DID 48DE
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 kW
Unit
kW

In testing for 2020 to 2026.

Coolant temperature LINCOLN_ECT

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2020 to 2026.

Coolant temperature LINCOLN_MAX_ECT

  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2020 to 2026.

Current gear LINCOLN_GEAR_V2

The automatic transmission gear. Numbers aren't yet mapped to named gears.

  • Service 22DID 1E12
  • Module7DF → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Cylinder 1 misfire count LINCOLN_MIS_CNT_1

  • Service 22DID 160E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Cylinder 2 misfire count LINCOLN_MIS_CNT_2

  • Service 22DID 160F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Cylinder 3 misfire count LINCOLN_MIS_CNT_3

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Cylinder 4 misfire count LINCOLN_MIS_CNT_4

  • Service 22DID 1611
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Cylinder 5 misfire count LINCOLN_MIS_CNT_5

  • Service 22DID 1612
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Cylinder 6 misfire count LINCOLN_MIS_CNT_6

  • Service 22DID 1613
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Cylinder 7 misfire count LINCOLN_MIS_CNT_7

  • Service 22DID 1614
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Cylinder 8 misfire count LINCOLN_MIS_CNT_8

  • Service 22DID 1615
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Cylinder head temperature LINCOLN_CYL_HEAD_T

  • Service 22DID 051D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Cylinder head temperature LINCOLN_CYL_HEAD_T_7E0

  • Service 22DID 1624
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2020 to 2026.

Cylinder head temperature LINCOLN_CYL_HEAD_T_7E0_2

  • Service 22DID F405
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Cylinder head temperature LINCOLN_PCM_CYL_HEAD_T_CORR

  • Service 22DID 0334
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2020 to 2026.

Cylinder head temperature, alternate LINCOLN_CYL_HEAD_T_ALT

  • Service 22DID 1685
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2811000
Range
0 to 18415 °F
Unit
°F

In testing for 2020 to 2026.

Cylinder head temperature, sensor 2 LINCOLN_PCM_CYL_HEAD_T_SENS_2_RAW

  • Service 22DID 05FC
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511.9843 °C
Unit
°C

In testing for 2020 to 2026.

Diesel exhaust fluid level LINCOLN_DEF_LEVEL

  • Service 22DID 0487
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 L
Unit
L

In testing for 2020 to 2026.

Diesel particulate filter delta pressure LINCOLN_DPF_DELTA_P

  • Service 22DID 116C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×7.928974
Range
0 to 519625 kPa
Unit
kPa

In testing for 2020 to 2026.

Diesel particulate filter regen status LINCOLN_DPF_REGEN_STAT

  • Service 22DID 0966
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val128
Range
0 to 1.99
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter regeneration status LINCOLN_DPF_REGEN_STAT_F48B

  • Service 22DID F48B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter soot level LINCOLN_DPF_SOOT_LEVEL_C974

  • Service 22DID C974
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+8.192
Range
0 to 73.72
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter soot level percentage LINCOLN_DPF_SOOT_LEVEL

  • Service 22DID 042C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0871944108−57.142857
Range
-57.14 to 5657 %
Unit
%

In testing for 2020 to 2026.

Diesel particulate filter soot load, variant 2 LINCOLN_DPF_SOOT_LOAD

  • Service 22DID 0579
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2020 to 2026.

Distance since DTC clear LINCOLN_DIST_DTC_CLR

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2020 to 2026.

Distance since last complete DPF regeneration LINCOLN_DIST_SINCE_COMPLETE_FD8A

  • Service 22DID FD8A
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.009977908
Range
0 to 653 km
Unit
km

In testing for 2020 to 2026.

Distance with MIL LINCOLN_MIL_DIST

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2020 to 2026.

DTC counter LINCOLN_DTC_CNT

  • Service 22DID D137
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Engine load LINCOLN_ENG_LOAD_PCT

Pelican can show this parameter as the engine load.

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every500 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Engine load LINCOLN_MAX_ENG_LOAD_PCT

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every500 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Engine load, actual LINCOLN_ENG_LOAD_ACT

Pelican can show this parameter as the engine load.

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every500 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

In testing for 2020 to 2026.

Engine load, actual LINCOLN_MAX_ENG_LOAD_ACT

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every500 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

In testing for 2020 to 2026.

Engine oil pressure LINCOLN_EOP

  • Service 22DID F45C
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Engine oil pressure - desired LINCOLN_EOP_DES

  • Service 22DID 05EF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2020 to 2026.

Engine oil temperature LINCOLN_EOT

  • Service 22DID 1310
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature LINCOLN_EOT_7DF

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID F45C
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature LINCOLN_EOT_V2

  • Service 22DID 1310
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Engine oil temperature, alternate LINCOLN_EOT_F45C

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID F45C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Engine oil temperature, variant 2 LINCOLN_EOT_VAR_2

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Engine reference torque LINCOLN_PCM_ENG_REFERENCE_TRQ

  • Service 22DID F463
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2020 to 2026.

Engine run time LINCOLN_ERT

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2020 to 2026.

Engine run time LINCOLN_RUN_TIME

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2020 to 2026.

Engine speed LINCOLN_RPM

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2020 to 2026.

EV supply equipment type detected LINCOLN_EV_SUP_EQUIPMENT

  • Service 22DID 4851
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Evaporative pressure sensor voltage LINCOLN_EVAP_V

  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2020 to 2026.

Evaporative pressure sensor, raw count LINCOLN_EVAP_RAW

  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Evaporative purge LINCOLN_EVAP_PURGE_CMD

  • Service 22DID 1166
  • Module7E0 → 7E8
  • Every500 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Exhaust back pressure LINCOLN_EXH_BACK_P

  • Service 22DID 1445
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29800
Range
0 to 2375 psi
Unit
psi

In testing for 2020 to 2026.

Exhaust gas recirculation LINCOLN_EGR

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Exhaust gas recirculation cooler inlet temperature LINCOLN_EGR_COOLER_INLET_T

  • Service 22DID 0569
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×391250
Range
-1022 to 1022 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas recirculation cooler outlet temperature LINCOLN_EGR_COOLER_OUTLET_T

  • Service 22DID 055D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×391250
Range
-1022 to 1022 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas recirculation duty cycle LINCOLN_EGR_DUTY

  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Exhaust gas recirculation inlet temperature LINCOLN_EGR_INLET_T

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756 °F
Unit
°F

In testing for 2020 to 2026.

Exhaust gas recirculation open LINCOLN_EGR_OPEN

  • Service 22DID 052E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Exhaust gas recirculation temperature LINCOLN_EGR_T_7E0

  • Service 22DID F46B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas recirculation temperature LINCOLN_EGR_T_7E0_7E0

  • Service 22DID 0543
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas recirculation temperature a LINCOLN_EGR_T

  • Service 22DID 115F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756 °F
Unit
°F

In testing for 2020 to 2026.

Exhaust gas recirculation throttle position signal LINCOLN_EGR_THROTTLE_POS_SIG

  • Service 22DID 096C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2020 to 2026.

Exhaust gas recirculation valve position measured LINCOLN_EGR_VLV_POS_MEAS

  • Service 22DID 09FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2020 to 2026.

Exhaust gas recirculation valve position, desired LINCOLN_EGR_VLV_POS_DES

  • Service 22DID 09D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2020 to 2026.

Exhaust gas temperature 1 LINCOLN_EXH_GAS_T_1

  • Service 22DID 03F4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature 2 LINCOLN_EXH_GAS_T_2

  • Service 22DID 03F5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature after oxidation catalyst, before particulate filter LINCOLN_EGT_PRE_DPF

  • Service 22DID 0992
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 1500 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature after particulate filter LINCOLN_EGT_POST_DPF

  • Service 22DID 1171
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 1500 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature after turbo, before oxidation catalyst LINCOLN_EGT_PRE_DOC

  • Service 22DID 0991
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 1500 °C
Unit
°C

In testing for 2020 to 2026.

Exhaust gas temperature, bank 1 LINCOLN_EGT_B1

  • Service 22DID F478
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

In testing for 2020 to 2026.

Forward sensing module automatic alignment offset LINCOLN_FSM_AUTOMATIC

  • Service 22DID A220
  • Module764 → 76C
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2020 to 2026.

Fuel pressure sensor voltage, low LINCOLN_LPFP_SENS_V

  • Service 22DID 054D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Fuel pressure, high desired LINCOLN_HPFP_DES

  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1.450377397
Range
0 to 3500 psi
Unit
psi

In testing for 2020 to 2026.

Fuel pressure, high desired LINCOLN_MAX_HPFP_DES

  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

In testing for 2020 to 2026.

Fuel pressure, low actual LINCOLN_LPFP_ACT

  • Service 22DID 0548
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10000137892
Range
0 to 200 psi
Unit
psi

In testing for 2020 to 2026.

Fuel pressure, low desired LINCOLN_LPFP_DES

  • Service 22DID 041F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4351000
Range
0 to 110 psi
Unit
psi

In testing for 2020 to 2026.

Fuel pump duty cycle, low pressure LINCOLN_LPFP_DUTY

  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Fuel pump pulse width, bank 1 LINCOLN_FUEL_PMP_WIDTH_BANK_1

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Number

In testing for 2020 to 2026.

Fuel pump pulse width, bank 2 LINCOLN_FUEL_PMP_WIDTH_BANK_2

  • Service 22DID 1142
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Number

In testing for 2020 to 2026.

Fuel rail sensor voltage, high pressure LINCOLN_HPFP_V

  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Fuel trim, long term LINCOLN_LTFT

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every500 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

In testing for 2020 to 2026.

Fuel trim, short term LINCOLN_MAX_STFT

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

In testing for 2020 to 2026.

Fuel trim, short term LINCOLN_STFT

Pelican can show this parameter as the short term fuel trim.

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

In testing for 2020 to 2026.

Generator coil temperature LINCOLN_GEN_COIL_T

  • Service 22DID 4972
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×180+320
Range
0 to 11796620 °F
Unit
°F

In testing for 2020 to 2026.

Generator coil temperature LINCOLN_GEN_COIL_T_7E6

  • Service 22DID 4820
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×95
Range
-58982 to 58980 °C
Unit
°C

In testing for 2020 to 2026.

Generator control LINCOLN_GEN_CTRL

  • Service 22DID 0378
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Generator current LINCOLN_GEN_CURRENT

  • Service 22DID 04F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78150000
Range
-511.8361 to 511.8205 A
Unit
A

In testing for 2020 to 2026.

Glow plug, commanded status LINCOLN_GLOW_PLUG_CMD_STAT

  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−4
Range
-4 to 251
Unit
Number

In testing for 2020 to 2026.

Grill shutter duty cycle LINCOLN_GRILL_SHUT_DC

  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Grill shutter position LINCOLN_GRILL_SHUTTER_POS

  • Service 22DID 0580
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

High voltage battery current LINCOLN_HIGH_V_BAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Service 22DID 480B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 A
Unit
A

In testing for 2020 to 2026.

High voltage current LINCOLN_HIGH_V_CURRENT

  • Service 22DID 480B
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 A
Unit
A

In testing for 2020 to 2026.

High voltage leakage resistance bus negative LINCOLN_HIGH_V_LEAKAGE_RES

  • Service 22DID 4812
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

In testing for 2020 to 2026.

High voltage leakage resistance bus overall, raw count LINCOLN_HIGH_V_LEAKAGE_RES_BUS_V2

  • Service 22DID 4813
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

High voltage leakage resistance bus positive LINCOLN_HIGH_V_LEAKAGE_RES_BUS

  • Service 22DID 4811
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

In testing for 2020 to 2026.

High voltage leakage resistance bus positive, raw count LINCOLN_HIGH_V_LEAKAGE_RES_BUS_POSITIVE

  • Service 22DID 4811
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Hydraulic pump motor current LINCOLN_HYDRAULIC_PMP_MOTOR

  • Service 22DID D00F
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 A
Unit
A

In testing for 2020 to 2026.

Ignition correction, cylinder 1 LINCOLN_IGN_CORR_CYL1

  • Service 22DID 03EC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

In testing for 2020 to 2026.

Ignition timing, cylinder 1 LINCOLN_IGN_TIM_CYL1

  • Service 22DID 116B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-80 to 80 °
Unit
°

In testing for 2020 to 2026.

In car temperature LINCOLN_CAR_T

  • Service 22DID DD04
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.875 °C
Unit
°C

In testing for 2020 to 2026.

Injection control pressure LINCOLN_INJ_CTRL_P

  • Service 22DID 1446
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×57100
Range
0 to 37354 psi
Unit
psi

In testing for 2020 to 2026.

Injection mode LINCOLN_INJ_MODE

  • Service 22DID 046F
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

In testing for 2020 to 2026.

Injection pressure regulator duty cycle LINCOLN_IPR_DUTY

  • Service 22DID 1434
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2020 to 2026.

Injector control module cam and crank sync LINCOLN_FICM_SYNC

  • Service 22DID 09CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2020 to 2026.

Injector control module logic power LINCOLN_FICM_LOGIC_POWER

  • Service 22DID 09CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256
Range
0 to 255 V
Unit
V

In testing for 2020 to 2026.

Injector control module main power LINCOLN_FICM_MAIN_POWER

  • Service 22DID 09D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256
Range
0 to 255 V
Unit
V

In testing for 2020 to 2026.

Injector impulse width LINCOLN_INJ_IMPULSE_WIDTH

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000022
Range
0 to 0.05 s
Unit
s

In testing for 2020 to 2026.

Intake air temperature 1 LINCOLN_IAT_1

  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2020 to 2026.

Intake air temperature 2 LINCOLN_IAT_2

  • Service 22DID 16A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×59−17.777778
Range
-17.77 to 36390 °C
Unit
°C

In testing for 2020 to 2026.

Intake temperature fault LINCOLN_IAT_FAULT

  • Service 22DID 0700
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Intake temperature sensor voltage LINCOLN_IAT_SENS_V

  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Intake temperature, alternate LINCOLN_IAT_ALT2

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Knock counter, cylinder 1 LINCOLN_PCM_CYL_1_KNK_COMB_PERF_CNT

  • Service 22DID 05AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Knock counter, cylinder 2 LINCOLN_PCM_CYL_2_KNK_COMB_PERF_CNT

  • Service 22DID 05AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Knock counter, cylinder 3 LINCOLN_PCM_CYL_3_KNK_COMB_PERF_CNT

  • Service 22DID 05AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Knock counter, cylinder 4 LINCOLN_PCM_CYL_4_KNK_COMB_PERF_CNT

  • Service 22DID 05AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Knock counter, cylinder 5 LINCOLN_PCM_CYL_5_KNK_COMB_PERF_CNT

  • Service 22DID 05B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Knock counter, cylinder 6 LINCOLN_PCM_CYL_6_KNK_COMB_PERF_CNT

  • Service 22DID 05B1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Knock sensor, 1 LINCOLN_KS1_RAW

  • Service 22DID 0403
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Knock sensor, 2 LINCOLN_KS2_RAW

  • Service 22DID 0404
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Lambda correction LINCOLN_CL_LC

  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8192
Range
-4 to 3.9
Unit
Number

In testing for 2020 to 2026.

Lambda, commanded LINCOLN_CL

The ratio of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.

  • Service 22DID 030F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.9999
Unit
Number

In testing for 2020 to 2026.

Leakage resistance bus overall LINCOLN_LEAKAGE_RES_BUS

  • Service 22DID 4813
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

In testing for 2020 to 2026.

Low oil pressure switch LINCOLN_LOW_OIL_P_SWITCH

  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Low voltage converter current, high side LINCOLN_LVB_DCDC_HV_CURRENT

  • Service 22DID 483A
  • Module746 → 74E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2020 to 2026.

Manifold absolute pressure, high resolution LINCOLN_MAP_HIRES

  • Service 22DID 0370
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 kPa
Unit
kPa

In testing for 2020 to 2026.

Manifold air temperature LINCOLN_MANIFOLD_AIR_T

  • Service 22DID 16E0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

In testing for 2020 to 2026.

Manifold pressure LINCOLN_MAP

  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000068947
Range
0 to 36 psi
Unit
psi

In testing for 2020 to 2026.

Manifold pressure sensor voltage LINCOLN_MAP_V

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Manifold temperature LINCOLN_MCT

  • Service 22DID 03CA
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 148.889 °C
Unit
°C

In testing for 2020 to 2026.

Mass airflow sensor frequency LINCOLN_MASS_AIRFLOW_SENS

  • Service 22DID 033D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 Hz
Unit
Hz

In testing for 2020 to 2026.

Misfire acceleration, cylinder 1 LINCOLN_PCM_MISF_ACCEL_CYL1_NORM

  • Service 22DID 0382
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.9843
Unit
Number

In testing for 2020 to 2026.

Misfire acceleration, cylinder 2 LINCOLN_PCM_MISF_ACCEL_CYL2_NORM

  • Service 22DID 0388
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.9843
Unit
Number

In testing for 2020 to 2026.

Misfire acceleration, cylinder 3 LINCOLN_PCM_MISF_ACCEL_CYL3_NORM

  • Service 22DID 038A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.9843
Unit
Number

In testing for 2020 to 2026.

Misfire acceleration, cylinder 4 LINCOLN_PCM_MISF_ACCEL_CYL4_NORM

  • Service 22DID 038B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.9843
Unit
Number

In testing for 2020 to 2026.

Misfire acceleration, cylinder 5 LINCOLN_PCM_MISF_ACCEL_CYL5_NORM

  • Service 22DID 038C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2020 to 2026.

Misfire acceleration, cylinder 6 LINCOLN_PCM_MISF_ACCEL_CYL6_NORM

  • Service 22DID 0398
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.9843
Unit
Number

In testing for 2020 to 2026.

Misfire events, latest cycle LINCOLN_PCM_MISF_EVENTS_LATEST_CYC

  • Service 22DID 0345
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2020 to 2026.

Misfire monitor status LINCOLN_MIS_MON_STAT

  • Service 22DID 03C0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Motor coil temperature LINCOLN_MOTOR_COIL_T

  • Service 22DID 481F
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×95+32
Range
-58950 to 59012 °F
Unit
°F

In testing for 2020 to 2026.

Motor electronic coolant temperature II LINCOLN_MOTOR_ELECTRONIC_ECT

  • Service 22DID 4983
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−39.8
Range
-39.8 to 419 °F
Unit
°F

In testing for 2020 to 2026.

Motor electronics coolant temperature LINCOLN_MOTOR_ELECTRONICS

  • Service 22DID 4832
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95+32
Range
0 to 491 °F
Unit
°F

In testing for 2020 to 2026.

Navigation altitude LINCOLN_SYNC_GPS_ALTITUDE

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Navigation heading LINCOLN_SYNC_GPS_HEADING

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 2020 to 2026.

O2 sensor voltage, rear LINCOLN_RO2_V

  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 1 V
Unit
V

In testing for 2020 to 2026.

Octane adjustment LINCOLN_OAR

  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16384
Range
0 to 1
Unit
Number

In testing for 2020 to 2026.

Oil life remaining LINCOLN_PCM_ENG_OIL_LIFE_REM

  • Service 22DID 054B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Oil pressure LINCOLN_PCM_ENG_EOP_RAW

  • Service 22DID 0415
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 2020 to 2026.

Outdoor temperature, BCM LINCOLN_OUTDOOR_T_BCM

  • Service 22DID DD05
  • Module760 → 768
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Outside temperature LINCOLN_OUTSIDE_T

  • Service 22DID DD05
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−38
Range
-38 to 421 °F
Unit
°F

In testing for 2020 to 2026.

Power transfer unit sump temperature LINCOLN_POWER_TRANSFER_UNIT_T

  • Service 22DID 0184
  • Module703 → 70B
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 °C
Unit
°C

In testing for 2020 to 2026.

Power transfer unit, requested torque LINCOLN_POWER_TRANSFER_UNIT_REQ_TQ

  • Service 22DID 0182
  • Module703 → 70B
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2020 to 2026.

Power transfer unit, requested torque capacity inferred LINCOLN_POWER_TRANSFER_UNIT_REQ_TQ_CAP

  • Service 22DID 0185
  • Module703 → 70B
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2020 to 2026.

Secondary motor torque, commanded LINCOLN_SECONDARY_MOTOR_TQ_CMD

  • Service 22DID 4819
  • Module7E7 → 7EF
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2020 to 2026.

Steering angle from the body module, actual value LINCOLN_BCM_STEER_ANG_ACT

  • Service 22DID 3302
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−780
Range
-780 to 5773 °
Unit
°

In testing for 2020 to 2026.

Steering shaft torque LINCOLN_STEER_SHFT_TQ

  • Service 22DID 330C
  • Module730
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−12.7
Range
-12.7 to 12.8 N·m
Unit
N·m

In testing for 2020 to 2026.

Sump oil temperature measured LINCOLN_SUMP_OIL_T_MEAS

  • Service 22DID 03F3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Temperature inside car LINCOLN_T_INSIDE_CAR

  • Service 22DID DD04
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

In testing for 2020 to 2026.

Throttle angle, actual LINCOLN_ETC_ANG_ACT

  • Service 22DID 093C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

In testing for 2020 to 2026.

Throttle angle, desired LINCOLN_ETC_ANG_DES

  • Service 22DID 091A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

In testing for 2020 to 2026.

Throttle control trim angle, learned LINCOLN_ETC_TRIM_LRN

  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

In testing for 2020 to 2026.

Throttle inlet pressure LINCOLN_TIP_ABS

  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 60 psi
Unit
psi

In testing for 2020 to 2026.

Throttle inlet pressure sensor voltage LINCOLN_TIP_V

  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51024
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Throttle inlet pressure, desired LINCOLN_TIP_DES_ABS

  • Service 22DID 0466
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 72.5 psi
Unit
psi

In testing for 2020 to 2026.

Time since last oil change LINCOLN_TIME_SINCE_OIL

  • Service 22DID 053F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20013107
Range
0 to 1000
Unit
Raw value

In testing for 2020 to 2026.

Torque converter slip LINCOLN_TQ_CONV_SLIP

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.638538424
Range
0 to 39996.0104 rpm
Unit
rpm

In testing for 2020 to 2026.

Torque into torque converter LINCOLN_TQ_INTO_TQ_CONV

  • Service 22DID 09CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.35581795
Range
0 to 48336.1353 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque into torque converter LINCOLN_TQ_INTO_TQ_CONV_7E0

  • Service 22DID 163A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2020 to 2026.

Torque request LINCOLN_TRQ_CTRL_REQ

  • Service 22DID 03AF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Total misfire count LINCOLN_TOT_MIS_CNT

  • Service 22DID 1616
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Transfer case fluid temperature LINCOLN_TRANSFER_CASE_FLUID_T

  • Service 22DID 070D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °C
Unit
°C

In testing for 2020 to 2026.

Transmission fluid temperature, variant 1 LINCOLN_ATF_T_VAR_1

  • Service 22DID 1674
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 °F
Unit
°F

In testing for 2020 to 2026.

Transmission fluid temperature, variant 2 LINCOLN_ATF_T_VAR_2

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1674
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2020 to 2026.

Transmission fluid temperature, variant 5 LINCOLN_ATF_T_VAR_5

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E3F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2026.

Transmission fluid temperature, variant 6 LINCOLN_ATF_T_VAR_6

  • Service 22DID 092C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2020 to 2026.

Transmission oil temperature LINCOLN_TOT_7E0

  • Service 22DID 1E1C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-500 to 500 °C
Unit
°C

In testing for 2020 to 2026.

Turbo boost LINCOLN_TURBO_BOOST

  • Service 22DID 09DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2020 to 2026.

Turbo inlet pressure LINCOLN_TURBO_INLET_P

  • Service 22DID 05BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2020 to 2026.

Variable geometry turbo duty cycle LINCOLN_VGT_DUTY

  • Service 22DID 096D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

In testing for 2020 to 2026.

Warm-ups since DTC clear LINCOLN_WARMUP_CLR

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Wastegate control LINCOLN_WASTEGATE_CTRL

  • Service 22DID 16E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×76350000
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Wastegate duty cycle LINCOLN_WGDC

  • Service 22DID 0462
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Yaw rate signal LINCOLN_YAW_RATE_SIG

  • Service 22DID 2B0B
  • Module760 → 768
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553
Unit
Raw value

In testing for 2020 to 2026.

Fuel

Air/fuel ratio LINCOLN_AIR_FUEL_RAT

  • Service 22DID F434
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000446787
Range
0 to 29.2801
Unit
Number

In testing for 2020 to 2026.

Cylinder 1 fuel balance correction LINCOLN_CYL_1_FUEL_BALANCE

  • Service 22DID 098A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 1 fuel quantity LINCOLN_CYL_1_FUEL_QTY

  • Service 22DID 04AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 2 fuel balance correction LINCOLN_CYL_2_FUEL_BALANCE

  • Service 22DID 098B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 2 fuel quantity LINCOLN_CYL_2_FUEL_QTY

  • Service 22DID 04AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 3 fuel balance correction LINCOLN_CYL_3_FUEL_BALANCE

  • Service 22DID 098C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 3 fuel quantity LINCOLN_CYL_3_FUEL_QTY

  • Service 22DID 04AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 4 fuel balance correction LINCOLN_CYL_4_FUEL_BALANCE

  • Service 22DID 098D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 4 fuel quantity LINCOLN_CYL_4_FUEL_QTY

  • Service 22DID 04AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 5 fuel balance correction LINCOLN_CYL_5_FUEL_BALANCE

  • Service 22DID 11D3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 5 fuel quantity LINCOLN_CYL_5_FUEL_QTY

  • Service 22DID 04AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 6 fuel balance correction LINCOLN_CYL_6_FUEL_BALANCE

  • Service 22DID 048F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 6 fuel quantity LINCOLN_CYL_6_FUEL_QTY

  • Service 22DID 04AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 7 fuel balance correction LINCOLN_CYL_7_FUEL_BALANCE

  • Service 22DID 04A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 7 fuel quantity LINCOLN_CYL_7_FUEL_QTY

  • Service 22DID 04B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 8 fuel balance correction LINCOLN_CYL_8_FUEL_BALANCE

  • Service 22DID 04A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Cylinder 8 fuel quantity LINCOLN_CYL_8_FUEL_QTY

  • Service 22DID 04B1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

In testing for 2020 to 2026.

Dilution of oil with fuel LINCOLN_DILUTION_OIL_FUEL

  • Service 22DID 054C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

Engine fuel rate LINCOLN_ENG_FUEL_RATE

  • Service 22DID F45E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L
Unit
L

In testing for 2020 to 2026.

Fuel correction, cylinder 1 LINCOLN_FUEL_CORR_CYL_1

  • Service 22DID 098A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2020 to 2026.

Fuel correction, cylinder 2 LINCOLN_FUEL_CORR_CYL_2

  • Service 22DID 098B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2020 to 2026.

Fuel correction, cylinder 3 LINCOLN_FUEL_CORR_CYL_3

  • Service 22DID 098C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2020 to 2026.

Fuel correction, cylinder 4 LINCOLN_FUEL_CORR_CYL_4

  • Service 22DID 098D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2020 to 2026.

Fuel correction, cylinder 5 LINCOLN_FUEL_CORR_CYL_5

  • Service 22DID 11D3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2020 to 2026.

Fuel correction, cylinder 6 LINCOLN_FUEL_CORR_CYL_6

  • Service 22DID 048F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

In testing for 2020 to 2026.

Fuel injection impulse width LINCOLN_FUEL_INJ_IMPULSE

  • Service 22DID 168B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val125000
Range
0 to 0.1 s
Unit
s

In testing for 2020 to 2026.

Fuel level LINCOLN_FLI

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Fuel level LINCOLN_FLI_16C1

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 16C1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518509
Range
0 to 200 %
Unit
%

In testing for 2020 to 2026.

Fuel pulse width LINCOLN_FUEL_WIDTH

  • Service 22DID 1410
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val125
Range
0 to 524 ms
Unit
ms

In testing for 2020 to 2026.

Fuel pump duty cycle LINCOLN_FUEL_PMP_DUTY

  • Service 22DID 1672
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532
Range
0 to 199.2187 %
Unit
%

In testing for 2020 to 2026.

Fuel rail pressure control LINCOLN_FUEL_RAIL_P_CTRL

  • Service 22DID 03C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2020 to 2026.

Fuel tank level LINCOLN_FLI_V2

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 6185
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Fuel tank pressure LINCOLN_FUEL_TANK_P

  • Service 22DID 1639
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val6.901311249
Range
0 to 9496.0214 psi
Unit
psi

In testing for 2020 to 2026.

Fuel temperature LINCOLN_FUEL_T

  • Service 22DID 0522
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Fuel temperature a LINCOLN_FUEL_T_7E0

  • Service 22DID 0429
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2020 to 2026.

Low side fuel rail pressure LINCOLN_LOW_SIDE_FUEL_RAIL_P

  • Service 22DID 064E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 kPa
Unit
kPa

In testing for 2020 to 2026.

Mass fuel, desired LINCOLN_MASS_FUEL_DES

  • Service 22DID 1412
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095
Unit
Number

In testing for 2020 to 2026.

Volume fuel, desired LINCOLN_VOLUME_FUEL_DES

  • Service 22DID 1411
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095
Unit
Number

In testing for 2020 to 2026.

Lights

Exterior lighting state LINCOLN_EXTERIOR_LIGHT_STATE

  • Service 22DID 407E
  • Module726 → 72E
  • Every1 s
  • Testing

Bit 0 of the reply.

Unit
Named states
States
Raw valueState
00
2161

In testing for 2020 to 2026.

High beam status LINCOLN_HIGH_BEAM

  • Service 22DID 7151
  • Module726 → 72E
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2
Unit
Off or on

In testing for 2020 to 2026.

LINCOLN

Accelerator Pedal Position LINCOLN_[ECU] Accelerator pedal position

  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.5
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Air conditioning compressor pressure LINCOLN_[ECU] AC Pressure

  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.2900754962
Range
-100 to 1000 psi
Unit
psi

In testing for 2020 to 2026.

Ambient air temperature sensor voltage LINCOLN_[ECU] AAT Sensor V

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048875855
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Barometric pressure LINCOLN_[ECU] Baro

  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0362553791
Range
8 to 20 psi
Unit
psi

In testing for 2020 to 2026.

Barometric pressure sensor voltage LINCOLN_[ECU] Baro Sensor V

  • Service 22DID 035A
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048875855
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Closed loop lambda correction LINCOLN_[ECU] CL Lambda Corr

  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8192
Range
-4 to 3.99
Unit
Number

In testing for 2020 to 2026.

Commanded lambda LINCOLN_[ECU] Commanded lambda

The ratio of of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.

  • Service 22DID 030F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000305176
Range
0 to 5
Unit
Number

In testing for 2020 to 2026.

Engine coolant temperature LINCOLN_[ECU] ECT

  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-40 to 148.889 °C
Unit
°C

In testing for 2020 to 2026.

High pressure fuel rail sensor voltage LINCOLN_[ECU] HPFP sensor voltage

  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048875855
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Low pressure fuel pump commanded duty cycle LINCOLN_[ECU] LPFP duty cycle

  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517578
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Manifold absolute pressure sensor voltage LINCOLN_[ECU] MAP voltage

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0009765625
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

Octane adjust ratio LINCOLN_[ECU] OAR

  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16384
Range
-1 to 1
Unit
Number

In testing for 2020 to 2026.

Rear O2 voltage LINCOLN_[ECU] Rear O2 V

  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0009765625
Range
0 to 1 V
Unit
V

In testing for 2020 to 2026.

Throttle inlet pressure absolute LINCOLN_[ECU] TIP actual abs

  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0011064263
Range
0 to 60 psi
Unit
psi

In testing for 2020 to 2026.

Throttle inlet pressure sensor voltage LINCOLN_[ECU] TIP sensor voltage

  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048828125
Range
0 to 5 V
Unit
V

In testing for 2020 to 2026.

VCT exhaust cam desired LINCOLN_[ECU] VCT Exh Des

  • Service 22DID 03BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
0 to 50 °
Unit
°

In testing for 2020 to 2026.

VCT exhaust camshaft actual LINCOLN_[ECU] VCT exhaust actual

  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

In testing for 2020 to 2026.

VCT exhaust camshaft error LINCOLN_[ECU] VCT exhaust error

  • Service 22DID 031B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

In testing for 2020 to 2026.

VCT exhaust camshaft solenoid duty cycle LINCOLN_[ECU] VCT exhaust duty cycle

  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517578
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

VCT intake cam desired LINCOLN_[ECU] VCT Int Des

  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 40 °
Unit
°

In testing for 2020 to 2026.

VCT intake camshaft actual LINCOLN_[ECU] VCT intake actual

  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

In testing for 2020 to 2026.

VCT intake camshaft solenoid duty cycle LINCOLN_[ECU] VCT intake duty cycle

  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517578
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

LINCOLN_ETC_TRIM

Electronic throttle control learned trim angle LINCOLN_ETC_TRIM_LEARNED

  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-63.9 to 64 °
Unit
°

In testing for 2020 to 2026.

Movement

Accelerator pedal position LINCOLN_ACCEL_PEDAL_POS

  • Service 22DID 09D4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2020 to 2026.

Actual output shaft speed LINCOLN_ACT_OUTPUT_SHFT_SPD

  • Service 22DID 1E1B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2020 to 2026.

Actual turbine shaft speed LINCOLN_ACT_TURBINE_SHFT_SPD

  • Service 22DID 1E13
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2020 to 2026.

Coolant pump a control speed, commanded LINCOLN_CLT_PMP_CTRL_SPD_CMD

  • Service 22DID 011A
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2020 to 2026.

Coolant pump b control speed, commanded LINCOLN_CLT_PMP_B_CTRL_SPD_CMD

  • Service 22DID 0117
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2020 to 2026.

Fan speed demanded LINCOLN_FAN_SPD_DEMANDED

  • Service 22DID 0701
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2020 to 2026.

Fan speed indicated LINCOLN_FAN_SPD_INDICATED

  • Service 22DID 0702
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2020 to 2026.

Fan speed sensor LINCOLN_FAN_SPD_SENS

  • Service 22DID 099F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2020 to 2026.

Fan speed, desired LINCOLN_FAN_SPD_DES

  • Service 22DID 03B9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4013107
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Front left wheel speed LINCOLN_FL_VSS

  • Service 22DID 2B07
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

In testing for 2020 to 2026.

Front right wheel speed LINCOLN_FR_VSS

  • Service 22DID 2B06
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

In testing for 2020 to 2026.

Lateral acceleration LINCOLN_LAT_G

  • Service 22DID 2B11
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-1 to 1
Unit
Number

In testing for 2020 to 2026.

Lateral angle, raw count LINCOLN_LAT_ANG

  • Service 22DID 2B0C
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2020 to 2026.

Navigation speed LINCOLN_SYNC_GPS_SPD

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×185
Range
0 to 235926 km/h
Unit
km/h

In testing for 2020 to 2026.

Power transfer unit input shaft speed LINCOLN_POWER_TRANSFER_UNIT

  • Service 22DID 017E
  • Module703 → 70B
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2020 to 2026.

Rear left wheel speed LINCOLN_RL_VSS

  • Service 22DID 2B09
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

In testing for 2020 to 2026.

Rear right wheel speed LINCOLN_RR_VSS

  • Service 22DID 2B08
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

In testing for 2020 to 2026.

Traction motor speed LINCOLN_TRACTION_MOTOR_SPD

  • Service 22DID 496A
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 rpm
Unit
rpm

In testing for 2020 to 2026.

Vehicle speed LINCOLN_MAX_VSS

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Vehicle speed LINCOLN_VSS

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Vehicle speed, high resolution LINCOLN_VSS_HD

  • Service 22DID 1505
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 200 km/h
Unit
km/h

In testing for 2020 to 2026.

Tires

4 wheel drive engaged LINCOLN_4_WHL_DRIVE_ENGAGED

  • Service 22DID A211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2020 to 2026.

Front left tire pressure LINCOLN_MAX_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 2813
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

In testing for 2020 to 2026.

Front left tire pressure LINCOLN_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 2813
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

In testing for 2020 to 2026.

Front right tire pressure LINCOLN_MAX_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 2814
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

In testing for 2020 to 2026.

Front right tire pressure LINCOLN_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 2814
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

In testing for 2020 to 2026.

Rear left inner tire pressure LINCOLN_TP_RLI

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2818
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

In testing for 2020 to 2026.

Rear left inner tire pressure slot LINCOLN_TP_RLI_RAW

A rear inner tire position, which this car does not have. Raw count; dual-wheel trucks read it at 1/20 psi.

  • Service 22DID 2818
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Rear left outer tire pressure LINCOLN_MAX_TP_RLO

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

In testing for 2020 to 2026.

Rear left outer tire pressure LINCOLN_TP_RLO

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

In testing for 2020 to 2026.

Rear left tire pressure LINCOLN_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 255 psi
Unit
psi

In testing for 2020 to 2026.

Rear right inner tire pressure LINCOLN_TP_RRI

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2817
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

In testing for 2020 to 2026.

Rear right inner tire pressure slot LINCOLN_TP_RRI_RAW

A rear inner tire position, which this car does not have. Raw count; dual-wheel trucks read it at 1/20 psi.

  • Service 22DID 2817
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Rear right outer tire pressure LINCOLN_MAX_TP_RRO

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

In testing for 2020 to 2026.

Rear right outer tire pressure LINCOLN_TP_RRO

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

In testing for 2020 to 2026.

Rear right tire pressure LINCOLN_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 255 psi
Unit
psi

In testing for 2020 to 2026.

Tire pressure warning indicator LINCOLN_TPMS_WARN

  • Service 22DID 61A5
  • Module720 → 728
  • Every15 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Tire pressure, rear left inner LINCOLN_MAX_TP_RLI

  • Service 22DID 2818
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

In testing for 2020 to 2026.

Tire pressure, rear right inner LINCOLN_MAX_TP_RRI

  • Service 22DID 2817
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

In testing for 2020 to 2026.

Tire temperature LINCOLN_MAX_TYRE_T

  • Service 22DID 280B
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Tire temperature LINCOLN_TYRE_T

  • Service 22DID 280B
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Transmission

Actual torque converter slip LINCOLN_ACT_TQ_CONV_SLIP

  • Service 22DID 1E14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2020 to 2026.

All-wheel drive clutch diagnostic signal LINCOLN_AWD_CLU_DIAGNOSTIC

  • Service 22DID 1E62
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

All-wheel drive clutch, commanded control signal LINCOLN_AWD_CLU_CMD_CTRL_SIG

  • Service 22DID 1E63
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Axle gear ratio, measured LINCOLN_AXLE_GEAR_RATIO_MEAS

  • Service 22DID 1E16
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 10
Unit
Number

In testing for 2020 to 2026.

Converter speed ratio LINCOLN_CONV_SPD_RAT

  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×582
Range
0 to 3996.0365
Unit
Number

In testing for 2020 to 2026.

Current gear LINCOLN_GEAR

The automatic transmission gear.

  • Service 22DID 1E12
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear
99Ninth gear
1010Tenth gear

In testing for 2020 to 2026.

Desired torque converter slip LINCOLN_DES_TQ_CONV_SLIP

  • Service 22DID 1E35
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2020 to 2026.

Gear LINCOLN_GEAR_7E1

  • Service 22DID 1E1F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047
Unit
Number

In testing for 2020 to 2026.

Gear commanded LINCOLN_GEAR_CMD

  • Service 22DID 1E12
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNKNOWNUnknown
20L
40D
50N
60R
70P
255FAULTFault

In testing for 2020 to 2026.

Gear ratio, commanded LINCOLN_PCM_CMD_TRANS_GEAR_RATIO

  • Service 22DID 1E19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1665535
Range
0 to 16
Unit
Number

In testing for 2020 to 2026.

Gear, engaged LINCOLN_GEAR_ENG

  • Service 22DID 1E1F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 2020 to 2026.

Measured current of clutch a actuator LINCOLN_MEAS_CURRENT_CLU

  • Service 22DID 1E9E
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 A
Unit
A

In testing for 2020 to 2026.

Shift gear LINCOLN_GEAR_SHFT

  • Service 22DID 1E23
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
10MANUALManual
46DRIVEDrive
50NEUTRALNeutral
60REVERSEReverse
70PARKPark

In testing for 2020 to 2026.

Shift gear LINCOLN_GEAR_SHFT_V2

  • Service 22DID 1E23
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Shift gear LINCOLN_GEAR_SHFT_V2_7DF

Selected range. Neutral, reverse and park are mapped; the code driving reports (43) is not yet.

  • Service 22DID 1E23
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
50NEUTRALNeutral
60REVERSEReverse
70PARKPark

In testing for 2020 to 2026.

Torque converter line pressure LINCOLN_TQ_CONV_LINE_P

  • Service 22DID 11C0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1723695000
Range
0 to 8790.819 kPa
Unit
kPa

In testing for 2020 to 2026.

Torque into torque converter, variant 2 LINCOLN_TQ_INTO_TQ_CONV_VAR_2

  • Service 22DID 163A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2020 to 2026.

Transmission fluid fluid quality LINCOLN_TRANS_FLUID_FLUID

  • Service 22DID 180F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Transmission gear LINCOLN_TRANS_GEAR

  • Service 22DID 11B3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

In testing for 2020 to 2026.

Transmission gear LINCOLN_TRANS_GEAR_7E1

  • Service 22DID 11B3
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

In testing for 2020 to 2026.

Transmission gear ratio LINCOLN_TRANS_GEAR_RAT

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×15.7480315
Range
0 to 4015.748
Unit
Number

In testing for 2020 to 2026.

Transmission odometer LINCOLN_TRANS_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Transmission oil temperature LINCOLN_TOT

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E1C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-40 to 255 °C
Unit
°C

In testing for 2020 to 2026.

Transmission oil temperature LINCOLN_TOT_V2

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E1C
  • Module7DF → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-500 to 500 °C
Unit
°C

In testing for 2020 to 2026.

Transmission output shaft speed LINCOLN_TRANS_OUTPUT_SHFT

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638.375 rpm
Unit
rpm

In testing for 2020 to 2026.

Transmission pressure, commanded LINCOLN_PCM_CMD_TRANS_MAIN_LINE_P

  • Service 22DID 1E1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534 kPa
Unit
kPa

In testing for 2020 to 2026.

Transmission temperature LINCOLN_TT

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E1C
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-300 to 300 °C
Unit
°C

In testing for 2020 to 2026.

Trips

Battery current, high range LINCOLN_CURRENT_HIGH_RANGE

  • Service 22DID 4809
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 A
Unit
A

In testing for 2020 to 2026.

Distance since last complete regeneration LINCOLN_DIST_SINCE_COMPLETE

  • Service 22DID 0434
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val×625
Range
0 to 4026531 mi
Unit
mi

In testing for 2020 to 2026.

Distance since last oil change LINCOLN_DIST_SINCE_OIL

  • Service 22DID 0542
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2020 to 2026.

Distance to empty, calculated LINCOLN_DTE

Pelican can show this parameter as the fuel range.

  • Service 22DID 4194
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2020 to 2026.

Distance to empty, displayed LINCOLN_DTE_DISP

Pelican can show this parameter as the fuel range.

  • Service 22DID 4195
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2020 to 2026.

HV battery current, low range LINCOLN_HVB_CURRENT_LOW

  • Service 22DID 480A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 A
Unit
A

In testing for 2020 to 2026.

Maximum battery temperature LINCOLN_HVBAT_T_MAX

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2026.

Minimum battery temperature LINCOLN_HVBAT_T_MIN

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2020 to 2026.

Odometer LINCOLN_BECM_ODO

  • Service 22DID 6182
  • Module7E4 → 7EC
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12815625
Range
0 to 536
Unit
Number

In testing for 2020 to 2026.

Odometer LINCOLN_IPC_ODO

  • Service 22DID 404C
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2020 to 2026.

Odometer LINCOLN_MAX_ODO_7E0

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Odometer LINCOLN_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Odometer LINCOLN_ODO_720

  • Service 22DID 6180
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2020 to 2026.

Odometer LINCOLN_ODO_7E0

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Odometer LINCOLN_ODO_V2

Pelican can show this parameter as the odometer.

  • Service 22DID 404C
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2020 to 2026.

Odometer, battery control module LINCOLN_ODO_BCM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module760 → 768
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Odometer, brake module LINCOLN_ABS_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module760 → 768
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Odometer, forward sensing module LINCOLN_ODO_FSM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module764 → 76C
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Odometer, instrument panel LINCOLN_MAX_ODO_726

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Odometer, instrument panel LINCOLN_ODO_726

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Odometer, power steering module LINCOLN_ODO_PSCM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module730 → 738
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2026.

Total distance, lifetime LINCOLN_TOT_DIST_LIFETIME

  • Service 22DID F817
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 km
Unit
km

In testing for 2020 to 2026.

Trip distance LINCOLN_ODO_TRIP

  • Service 22DID DD01
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2020 to 2026.

Vehicle odometer LINCOLN_PCM_VEH_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID F4A6
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

In testing for 2020 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.