Parameters
The Lincoln Aviator has 528 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery age LINCOLN_12V_AGE
- Service 22
DID 4027 - Module
726 → 72E - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1572840 h
- Unit
- h
In testing for 2003 to 2005, 2020 to 2026.
12V battery current LINCOLN_VEH_BAT_CURRENT
- Service 22
DID 402B - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -127 to 128 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
12V battery voltage LINCOLN_12V_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 402A - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 18.75 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Aux 12V battery control mode LINCOLN_AUX_12V_BAT_CTRL
- Service 22
DID 40D1 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Average battery module voltage LINCOLN_AVG_BAT_MODULE_V
- Service 22
DID 4841 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Battery age LINCOLN_BATT_AGE
- Service 22
DID 4027 - Module
726 → 72E - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1825
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Battery capacity LINCOLN_BAT_CAP
- Service 22
DID 485C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 Ah
- Unit
- Ah
In testing for 2003 to 2005, 2020 to 2026.
Battery capacity too low for start/stop LINCOLN_BAT_CAP_TOO_LOW
- Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Battery charge LINCOLN_BATT_SOC
- Service 22
DID 4028 - Module
726 → 72E - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Battery current too high for start/stop LINCOLN_BAT_CURRENT_TOO_HIGH
- Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Battery current, predicted LINCOLN_BAT_CURRENT
- Service 22
DID 4209 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -2097152 to 2097151.75 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
Battery discharge power limit LINCOLN_BAT_DCHG_POWER_LIM
- Service 22
DID 4852 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kW
- Unit
- kW
In testing for 2003 to 2005, 2020 to 2026.
Battery pack lifetime charge out, throughput LINCOLN_BAT_PACK_LIFETIME
- Service 22
DID 485D - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 Ah
- Unit
- Ah
In testing for 2003 to 2005, 2020 to 2026.
Battery percentage, state of charge LINCOLN_BAT_PERCENTAGE_ST
- Service 22
DID 4028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Battery quiescent current, low range LINCOLN_BAT_QUIESCENT
- Service 22
DID 4025 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1000 to 31767.5 mA
- Unit
- mA
In testing for 2003 to 2005, 2020 to 2026.
Battery refresh cycle in progress for start/stop LINCOLN_BAT_REFRESH_CYCLE
- Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Battery state detection status LINCOLN_BAT_ST_DETECTION
- Service 22
DID 420A - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Battery state of charge too low for start/stop LINCOLN_BAT_ST_CHG_TOO_LOW
- Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Battery temperature LINCOLN_BATT_TEMP
- Service 22
DID 4029 - Module
726 → 72E - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 100 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Battery temperature too low for auto stop LINCOLN_BAT_T_TOO_LOW_AUTO
- Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Battery voltage LINCOLN_BAT_V
- Service 22
DID 1172 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.9375 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Battery voltage LINCOLN_BAT_V_7E0
- Service 22
DID F442 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Battery voltage too low for auto restart LINCOLN_BAT_V_TOO_LOW_AUTO
- Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Battery voltage too low for cold cranking capability LINCOLN_BAT_V_TOO_LOW_COLD
- Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Battery voltage too low for start/stop LINCOLN_BAT_V_TOO_LOW_START
- Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Charge air cooler temperature LINCOLN_CHG_AIR_COOLER_T
- Service 22
DID 0508 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 524280
- Unit
- Raw value
In testing for 2003 to 2005, 2020 to 2026.
Charge air temperature LINCOLN_CHG_AIR_T
- Service 22
DID 051C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Charger digital mode LINCOLN_EVSE_DIGITAL_MODE
- Service 22
DID 48B7 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | DC_E_MINUS | DC E- |
2 | DC_MINUS_P | DC -P |
3 | DC_EP | DC EP |
4 | AC_E_MINUS | AC E- |
5 | AC_MINUS_P | AC -P |
6 | AC_EP | AC EP |
7 | RESET | Reset |
8 | OFF | Off |
9 | ESTABLISH | Establish |
10 | FAULT | Fault |
In testing for 2003 to 2005, 2020 to 2026.
Charger input power available LINCOLN_CHARGER_INPUT_POWER
- Service 22
DID 484E - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 327 kW
- Unit
- kW
In testing for 2003 to 2005, 2020 to 2026.
Charger output voltage LINCOLN_CHARGER_OUTPUT_V
- Service 22
DID 484A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Charger type LINCOLN_EVSE_TYPE
- Service 22
DID 4851 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | LEVEL_1 | Level 1 |
2 | LEVEL_2 | Level 2 |
3 | DC | |
4 | BASIC | Basic |
5 | HIGH_LEVEL | High Level |
6 | BASIC_AC | Basic AC |
7 | HIGH_LEVEL_AC | High Level AC |
8 | HIGH_LEVEL_DC | High Level DC |
10 | NO_COMM | No communication |
11 | FAULT | Fault |
12 | HANDSHAKE_END | Handshake end |
In testing for 2003 to 2005, 2020 to 2026.
Charging state LINCOLN_CHRG_STATE
Pelican can show this parameter as the charging state.
- Service 22
DID 484F - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NOT_READY | Not ready |
1 | READY | Ready |
2 | FAULT | Fault |
3 | WAIT | Wait Check |
4 | PRE_COND | Pre-condition |
5 | CHARGING | Charging |
6 | DONE | Done |
7 | EXT | External Charger |
8 | INIT | Initializing |
In testing for 2003 to 2005, 2020 to 2026.
Commanded generator voltage LINCOLN_CMD_GEN_V
- Service 22
DID 0304 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Contactor voltage negative LINCOLN_CONTACTOR_V_NEG
- Service 22
DID 4806 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Contactor voltage negative LINCOLN_CONTACTOR_V_NEGATIVE
- Service 22
DID 4806 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.34 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Contactor voltage positive LINCOLN_CONTACTOR_V_POS
- Service 22
DID 4805 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Contactor voltage positive LINCOLN_CONTACTOR_V_POSITIVE
- Service 22
DID 4805 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.34 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
DC charger status LINCOLN_DC_CHARGER_STAT
- Service 22
DID 489E - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
DC charging system contactor voltage LINCOLN_DC_CHG_SYSTEM_V
- Service 22
DID 48AF - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
DC-DC converter LINCOLN_DCDC_ENABLED
- Service 22
DID 483D - Module
746 → 74E - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
High voltage AC charger coupler temperature LINCOLN_HIGH_V_AC_CHARGER_COUPLER_T
- Service 22
DID D117 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 419 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
High voltage AC charger coupler temperature LINCOLN_HIGH_V_AC_CHARGER_T
- Service 22
DID 4888 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 419 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
High voltage battery intake air temperature LINCOLN_HVBAT_IAT
- Service 22
DID 000F - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -39.8 to 419 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
High voltage charger current, requested LINCOLN_HIGH_V_CHARGER
- Service 22
DID 4842 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
High voltage charger input power available, raw count LINCOLN_HIGH_V_CHARGER_INPUT
- Service 22
DID 484E - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
High voltage charger output current measured LINCOLN_HIGH_V_CHARGER_OUTPUT
- Service 22
DID 4850 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
High voltage charger output reduction temperature LINCOLN_HIGH_V_CHARGER_T
- Service 22
DID 48A5 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
High voltage charger output voltage, raw count LINCOLN_HIGH_V_CHARGER_V
- Service 22
DID 484A - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
High voltage charger pilot voltage LINCOLN_HIGH_V_CHARGER_PILOT_V
- Service 22
DID 48B6 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
High voltage charger pilot voltage, raw count LINCOLN_HIGH_V_CHARGER_PILOT_V_RAW
- Service 22
DID 48BC - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
High voltage charger status LINCOLN_HIGH_V_CHARGER_STAT
- Service 22
DID 484D - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
High voltage charger status LINCOLN_HIGH_V_CHARGER_STAT_7E2
- Service 22
DID 484F - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
High voltage charger voltage, requested LINCOLN_HIGH_V_CHARGER_V_REQ
- Service 22
DID 4844 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
High voltage charger, maximum power LINCOLN_HIGH_V_CHARGER_MAX
- Service 22
DID 48C4 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kW
- Unit
- kW
In testing for 2003 to 2005, 2020 to 2026.
High voltage DC charger coupler temperature LINCOLN_HIGH_V_DC_CHARGER_T
- Service 22
DID D00C - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 419 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
High voltage DC charger coupler temperature 1 LINCOLN_HIGH_V_DC_CHARGER_T_1
- Service 22
DID 4897 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 419 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
High voltage DC charger coupler temperature 3 LINCOLN_HIGH_V_DC_CHARGER_T_3
- Service 22
DID 48A4 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 419 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
High voltage DC charger status LINCOLN_HIGH_V_DC_CHARGER
- Service 22
DID 489E - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
High voltage DC charger, maximum voltage LINCOLN_HIGH_V_DC_CHARGER_MAX_V
- Service 22
DID 489D - Module
6F5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
High voltage DC charger, maximum, current LINCOLN_HIGH_V_DC_CHARGER_MAX
- Service 22
DID 4899 - Module
6F5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
High-voltage battery current LINCOLN_HVB_CURRENT
- Service 22
DID 48F9 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
High-voltage battery voltage, raw count LINCOLN_HVB_V_RAW_CNT
- Service 22
DID 480D - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
HV AC charger coupler temperature LINCOLN_AC_CHG_COUPLER_T
- Service 22
DID 4888 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
HV AC charger input current LINCOLN_AC_CHG_IN_A
- Service 22
DID 485F - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
HV AC charger input frequency LINCOLN_AC_CHG_IN_FREQ
- Service 22
DID 4860 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 90 Hz
- Unit
- Hz
In testing for 2003 to 2005, 2020 to 2026.
HV AC charger input voltage LINCOLN_AC_CHG_IN_V
- Service 22
DID 485E - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
HV battery age LINCOLN_HVBAT_AGE
- Service 22
DID 4810 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 235926 h
- Unit
- h
In testing for 2003 to 2005, 2020 to 2026.
HV battery average module voltage LINCOLN_HVBAT_AVG_MOD_V
- Service 22
DID 4841 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 50 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
HV battery charge LINCOLN_HVBAT_SOC
High resolution state of charge.
Pelican can show this parameter as the state of charge.
- Service 22
DID 4801 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
HV battery charge current requested LINCOLN_HVBAT_CCR
- Service 22
DID 4842 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 600 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
HV battery charge power limit LINCOLN_HVBAT_CHG_PWR_LIM
- Service 22
DID 48FB - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kW
- Unit
- kW
In testing for 2003 to 2005, 2020 to 2026.
HV battery charge voltage requested LINCOLN_HVBAT_CVR
- Service 22
DID 4844 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 500 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
HV battery charge, displayed LINCOLN_HVBAT_SOC_DISP
The state of charge displayed on the vehicle's dashboard.
Pelican can show this parameter as the state of charge.
- Service 22
DID 4845 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
HV battery charging status LINCOLN_HVBAT_CHG_STATUS
- Service 22
DID 484D - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NOT_READY | Not ready |
1 | WAIT | Wait |
2 | READY | Ready |
3 | CHARGING | Charging |
4 | DONE | Done |
5 | FAULT | Fault |
In testing for 2003 to 2005, 2020 to 2026.
HV battery coolant inlet temperature LINCOLN_HVBAT_COOLANT_INLET_T
- Service 22
DID 4846 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
HV battery current LINCOLN_HVBAT_A
Pelican can show this parameter as the traction battery current.
- Service 22
DID 48F9 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -600 to 600 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
HV battery current high range LINCOLN_HVBAT_CHR_A
- Service 22
DID 4809 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
HV battery current, alternate LINCOLN_HVBAT_A_ALT
- Service 22
DID 480B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -300 to 300 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
HV battery energy LINCOLN_HVBAT_KWH
- Service 22
DID 4848 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131.07 kWh
- Unit
- kWh
In testing for 2003 to 2005, 2020 to 2026.
HV battery maximum charge current LINCOLN_HVBAT_MAX_CHG_A
- Service 22
DID 48BC - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
HV battery minimum module voltage LINCOLN_HVBAT_MIN_MOD_V
- Service 22
DID 4840 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
HV battery modules voltage LINCOLN_HVBAT_MOD_V
- Service 22
DID 483F - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
HV battery state of health LINCOLN_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Service 22
DID 490C - Module
7E4 → 7EC - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
HV battery temperature LINCOLN_HVBAT_T
- Service 22
DID 4800 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
HV battery temperature range, maximum LINCOLN_T_RANGE_MAX
- Service 22
DID 4808 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
HV battery temperature range, minimum LINCOLN_T_RANGE_MIN
- Service 22
DID 4808 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
HV battery temperature, average LINCOLN_HVBAT_T_AVG
- Service 22
DID 4808 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
HV battery thermal operation mode LINCOLN_HVBAT_THERMAL_OP_MODE
- Service 22
DID 48E0 - Module
7E6 → 7EE - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Off |
1 | EQUALIZE | Equalize |
2 | COOLANT_FLOW | Coolant flow |
3 | COOLANT_FAN | Coolant fan |
4 | COOLANT_MODERATE | Coolant moderate |
5 | COOLANT_MAX | Coolant maximum |
15 | HEAT | Heat |
In testing for 2003 to 2005, 2020 to 2026.
HV battery voltage LINCOLN_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 480D - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
HV charger input power available LINCOLN_CHG_PWR_AVAIL
- Service 22
DID 484E - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 327.675 kW
- Unit
- kW
In testing for 2003 to 2005, 2020 to 2026.
HV charger maximum power LINCOLN_CHG_MAX_PWR
- Service 22
DID 48C4 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 kW
- Unit
- kW
In testing for 2003 to 2005, 2020 to 2026.
HV charger output current measured LINCOLN_CHG_OUT_A
- Service 22
DID 4850 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 600 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
HV charger output reduction temperature LINCOLN_CHG_OUT_REDUCT_T
- Service 22
DID 48A5 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
HV charger output voltage LINCOLN_CHG_OUT_V
- Service 22
DID 484A - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 600 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
HV charger pilot duty cycle LINCOLN_CHG_PILOT_DUTY
- Service 22
DID 4861 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
HV charger pilot voltage LINCOLN_CHG_PILOT_V
- Service 22
DID 48B6 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 15 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
HV charger proximity status LINCOLN_CHG_PROX_STATUS
- Service 22
DID 4862 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Off |
1 | ON_S3 | On S3 |
2 | ON | On |
3 | 10A | 10 A |
4 | 13A | 13 A |
5 | 16A | 16 A |
6 | 20A | 20 A |
7 | FAULT | Fault |
8 | 32A | 32 A |
9 | 63A | 63 A |
16 | DC | |
17 | OPEN | Open |
18 | SHORT | Short |
19 | SHORT_PWR | Short to power |
20 | OUT_OF_RANGE | Out of range |
21 | OPEN_CIRCUIT | Open circuit |
In testing for 2003 to 2005, 2020 to 2026.
HV charger proximity voltage LINCOLN_CHG_PROX_V
- Service 22
DID 48A0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
HV DC charger coupler temperature 1 LINCOLN_DC_CHG_COUPLER_T1
- Service 22
DID 4897 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
HV DC charger coupler temperature 3 LINCOLN_DC_CHG_COUPLER_T3
- Service 22
DID 48A4 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
HV DC charger maximum current LINCOLN_HVDC_CHG_MAX_C
- Service 22
DID 4899 - Module
6F5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
HV DC charger maximum voltage LINCOLN_HVDC_CHG_MAX_V
- Service 22
DID 489D - Module
6F5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
HV DC charger status LINCOLN_DC_CHG_STATUS
- Service 22
DID 489E - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NOT_READY | Not ready |
1 | INIT | Initialize |
2 | READY | Ready |
3 | WAIT_CHECK | Wait check |
4 | PRE_CONDITION | Pre-condition |
5 | CHARGING | Charging |
6 | DONE | Done |
8 | WAIT | Wait |
9 | NOT_CAPABLE | Not capable |
10 | FAULT | Fault |
11 | CHARGER_CHECK | Charger check |
In testing for 2003 to 2005, 2020 to 2026.
HV negative leakage voltage LINCOLN_HV_NEG_LEAK_V
- Service 22
DID 4804 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
HV positive leakage voltage LINCOLN_HV_POS_LEAK_V
- Service 22
DID 4803 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Hybrid battery pack remaining charge LINCOLN_HYBRID_BAT_PACK
- Service 22
DID F45B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Injection control pressure sensor voltage LINCOLN_ICP_V
- Service 22
DID 16AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Low voltage converter input current LINCOLN_DCDC_HV_A
- Service 22
DID 483A - Module
746 → 74E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
Low voltage converter output current LINCOLN_DCDC_LV_A
- Service 22
DID 4836 - Module
746 → 74E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
Maximum discharge power limit LINCOLN_MAX_DISCH_PWR_LIM
- Service 22
DID 4815 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 63.75 kW
- Unit
- kW
In testing for 2003 to 2005, 2020 to 2026.
Minimum battery module voltage LINCOLN_BATT_MIN_BATT_V
- Service 22
DID 4840 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Normalized cumulative charge when ignition is on LINCOLN_NORM_CUM_CHG_IGN_ON
- Service 22
DID 401E - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Normalized cumulative discharge from battery with engine off LINCOLN_NORM_CUM_DCHG_BAT_OFF
- Service 22
DID 4026 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Normalized cumulative discharge from battery with engine on LINCOLN_NORM_CUM_DCHG_BAT_ON
- Service 22
DID 4021 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
PF differential pressure feedback EGR sensor voltage LINCOLN_PF_DIFF_P_FEEDBACK_V
- Service 22
DID 03E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.01 to 32.01 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Second battery current LINCOLN_VEH_BAT_B_CURRENT
- Service 22
DID 423C - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1024 to 1023.96 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
Second battery voltage LINCOLN_VEH_BAT_B_V
- Service 22
DID 41E8 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 6 to 18.75 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
State of charge spread across battery modules LINCOLN_BATT_SOC_V2
- Service 22
DID 483E - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Target/desired state of charge LINCOLN_TARGET_SOC
- Service 22
DID 05A1 - Module
7E4 → 7EC - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Temperature range LINCOLN_T_RANGE
- Service 22
DID 4808 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Temperature range average LINCOLN_T_RANGE_AVG
- Service 22
DID 4808 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Traction battery voltage, alternate LINCOLN_TRACTION_BAT_V_ALT
- Service 22
DID 490B - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 199 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Vehicle battery voltage LINCOLN_VEH_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 402A - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 6 to 18.75 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Voltage spread across battery modules LINCOLN_BAT_V_VARIATION_BAT
- Service 22
DID 483F - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Climate
A/C compressor current LINCOLN_AC_COMP_A
- Service 22
DID 99AB - Module
7C7 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -100 to 100 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
A/C compressor pressure LINCOLN_AC_P
- Service 22
DID 0393 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
A/C compressor pressure sensor voltage LINCOLN_AC_P_SENS_V
- Service 22
DID 9800 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
A/C compressor, state LINCOLN_AC_STATE
- Service 22
DID 099B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
A/C refrigerant pressure LINCOLN_PCM_A_C_REFRIG_P
- Service 22
DID 0604 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Ambient temperature sensor voltage LINCOLN_AAT_V
- Service 22
DID 03BA - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Ambient temperature, alternate LINCOLN_AAT_ALT
- Service 22
DID 057D - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Coolant heater operation mode LINCOLN_COOLANT_HTR_OP_MODE
- Service 22
DID 48DF - Module
7E6 → 7EE - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Off |
1 | ON | On |
2 | DEGRADED | Degraded |
3 | SHUTDOWN | Shutdown |
4 | SHORT | Short |
5 | NO_RESPONSE | No response |
6 | UNKNOWN | Unknown |
7 | STOP | Stop |
In testing for 2003 to 2005, 2020 to 2026.
Coolant heater power LINCOLN_COOLANT_HTR_PWR
- Service 22
DID 48DE - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 kW
- Unit
- kW
In testing for 2003 to 2005, 2020 to 2026.
Exterior temperature LINCOLN_AAT
- Service 22
DID DD05 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Interior temperature LINCOLN_IAT
- Service 22
DID DD04 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Control
Anti-lock brake lateral acceleration LINCOLN_ABS_LATERAL_ACCEL
- Service 22
DID 3A51 - Module
760 → 768 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g
- Unit
- g
In testing for 2003 to 2005, 2020 to 2026.
Anti-lock brake wheel speed 1 LINCOLN_ABS_WHL_SPD_1
- Service 22
DID 3987 - Module
760 → 768 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Anti-lock brake wheel speed 2 LINCOLN_ABS_WHL_SPD_2
- Service 22
DID 3987 - Module
760 → 768 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Anti-lock brake wheel speed 3 LINCOLN_ABS_WHL_SPD_3
- Service 22
DID 3987 - Module
760 → 768 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Anti-lock brake wheel speed 4 LINCOLN_ABS_WHL_SPD_4
- Service 22
DID 3987 - Module
760 → 768 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Brake booster pressure LINCOLN_BRAKE_BOOSTER_P
- Service 22
DID 2028 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Brake hydraulic pressure, raw count LINCOLN_BRK_FL_P
- Service 22
DID 2B0D - Module
760 → 768 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Foot brake LINCOLN_FOOT_BRAKE
- Service 22
DID 3B40 - Module
703 → 70B - Every
250 ms - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Parking brake state LINCOLN_PARKING_BRAKE
- Service 22
DID 2B00 - Module
760 → 768 - Every
3 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Steering wheel angle LINCOLN_STEER_ANGLE
Positive is rotated to the left, negative is rotated to the right.
- Service 22
DID 3201 - Module
760 → 768 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1638 to 1638 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Cruise control
Target vehicle speed LINCOLN_CC_TGT_VSS
The speed of the vehicle ahead of you.
- Service 22
DID A224 - Module
764 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -736 to 736 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Doors
Driver door ajar LINCOLN_DRIVER_DOOR_OPEN
- Service 22
DID C150 - Module
726 → 72E - Every
3 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2003 to 2005, 2020 to 2026.
Hood ajar? LINCOLN_HOOD_OPEN
- Service 22
DID C154 - Module
726 → 72E - Every
3 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2003 to 2005, 2020 to 2026.
Lock status LINCOLN_CENTRAL_LOCK_STATUS
- Service 22
DID C259 - Module
726 → 72E - Every
2 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | UNLOCKED | Unlocked |
2 | LOCKED | Locked |
In testing for 2003 to 2005, 2020 to 2026.
Passenger door ajar? LINCOLN_PASSENGER_DOOR_OPEN
- Service 22
DID C150 - Module
726 → 72E - Every
3 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2003 to 2005, 2020 to 2026.
Rear left door ajar? LINCOLN_RLD_OPEN
- Service 22
DID C150 - Module
726 → 72E - Every
3 s - Testing
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2003 to 2005, 2020 to 2026.
Rear right door ajar? LINCOLN_RRD_OPEN
- Service 22
DID C150 - Module
726 → 72E - Every
3 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2003 to 2005, 2020 to 2026.
Trunk ajar? LINCOLN_TRUNK_OPEN
- Service 22
DID C150 - Module
726 → 72E - Every
3 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2003 to 2005, 2020 to 2026.
Drivetrain
Primary motor coil temperature LINCOLN_PRI_MOTOR_COIL_T
- Service 22
DID 481F - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 300 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Primary motor inverter temperature LINCOLN_PRI_MOTOR_INV_T
- Service 22
DID 4824 - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 300 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Primary motor inverter voltage LINCOLN_PRI_MOTOR_INV_V
- Service 22
DID 481D - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -400 to 400 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Primary motor speed LINCOLN_PRI_MOTOR_RPM
- Service 22
DID 1E2C - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6000 to 12000 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
Primary motor torque LINCOLN_PRI_MOTOR_TQ
- Service 22
DID 481C - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -200 to 200 N·m
- Unit
- N·m
In testing for 2003 to 2005, 2020 to 2026.
Secondary motor coil temperature LINCOLN_SEC_MOTOR_COIL_T
- Service 22
DID 4820 - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 300 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Secondary motor inverter temperature LINCOLN_SEC_MOTOR_INV_T
- Service 22
DID 481E - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 300 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Secondary motor inverter voltage LINCOLN_SEC_MOTOR_INV_V
- Service 22
DID 4823 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -400 to 400 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Secondary motor speed LINCOLN_SEC_MOTOR_RPM
- Service 22
DID 4821 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6000 to 12000 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
Secondary motor torque LINCOLN_SEC_MOTOR_TQ
- Service 22
DID 481A - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -200 to 200 N·m
- Unit
- N·m
In testing for 2003 to 2005, 2020 to 2026.
Engine
Accelerator position LINCOLN_ACC_POS
- Service 22
DID 032B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Actual engine percent torque LINCOLN_PCM_ACT_ENG_PCT_TRQ
- Service 22
DID F462 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Actuator cam position corrected LINCOLN_ACTUATOR_CAM_POS
- Service 22
DID 017C - Module
703 → 70B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Actuator duty cycle output, commanded LINCOLN_ACTUATOR_DUTY_OUTPUT_CMD
- Service 22
DID 017F - Module
703 → 70B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -127 to 127 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Air conditioning pressure LINCOLN_AC_P_7E0
- Service 22
DID FD18 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 3100 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Alternator 2 monitor LINCOLN_ALTERNATOR_2_MON
- Service 22
DID 0455 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Alternator current output LINCOLN_ALTERNATOR_CURRENT
- Service 22
DID D113 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
Ambient air temperature LINCOLN_AAT_7E0
- Service 22
DID F446 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Barometric pressure LINCOLN_BARO
- Service 22
DID 0353 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 8 to 20 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Barometric pressure LINCOLN_BAROMETRIC_P
- Service 22
DID 1127 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1079.4118 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Barometric pressure sensor voltage LINCOLN_BARO_V
- Service 22
DID 035A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Battery current LINCOLN_BAT_CURRENT_726
- Service 22
DID 4090 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -511.7 to 3584.2375 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
Boost LINCOLN_BOOST
- Service 22
DID 1440 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Bypass valve LINCOLN_BPV_OPEN
- Service 22
DID 0427 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Calculated soot in oil LINCOLN_CALC_SOOT_OIL
- Service 22
DID 0508 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 8
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Camshaft position error, exhaust LINCOLN_VCT_EXH_ERR
- Service 22
DID 031B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 50 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Camshaft position error, intake LINCOLN_VCT_INT_ERR
- Service 22
DID 031A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -50 to 50 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Camshaft position, exhaust actual LINCOLN_VCT_EXH_ACT
- Service 22
DID 0319 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 50 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Camshaft position, exhaust desired LINCOLN_VCT_EXH_DES
- Service 22
DID 03BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2047 to 2047 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Camshaft position, intake actual LINCOLN_VCT_INT_ACT
- Service 22
DID 0318 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Camshaft position, intake desired LINCOLN_VCT_INT_DES
- Service 22
DID 03BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2047 to 2047 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Camshaft solenoid duty cycle, exhaust LINCOLN_VCT_EXH_DUTY
- Service 22
DID 0317 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Camshaft solenoid duty cycle, intake LINCOLN_VCT_INT_DUTY
- Service 22
DID 0316 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Catalyst temperature LINCOLN_CAT_TEMP
- Service 22
DID F43C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Charge air temperature LINCOLN_CAT
- Service 22
DID 0461 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 189 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Charge air temperature 2 LINCOLN_CHG_AIR_T_2
- Service 22
DID 0461 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 189 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Charge air temperature sensor voltage LINCOLN_CAT_SENS_V
- Service 22
DID 0460 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Charging inhibit - requested LINCOLN_CHG_INHIBIT_REQ
- Service 22
DID 4878 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Charging station connection, raw count LINCOLN_EVSE_CHG_RAW_CNT
- Service 22
DID 4851 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Commanded generator duty LINCOLN_CMD_GEN_DUTY
- Service 22
DID 16E8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Coolant heater power LINCOLN_CLT_HEATER_POWER
- Service 22
DID 48DE - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 kW
- Unit
- kW
In testing for 2003 to 2005, 2020 to 2026.
Coolant temperature LINCOLN_ECT
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 038F - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Coolant temperature LINCOLN_MAX_ECT
- Service 22
DID 038F - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Current gear LINCOLN_GEAR_V2
The automatic transmission gear. Numbers aren't yet mapped to named gears.
- Service 22
DID 1E12 - Module
7DF → 7E9 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 1 misfire count LINCOLN_MIS_CNT_1
- Service 22
DID 160E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 2 misfire count LINCOLN_MIS_CNT_2
- Service 22
DID 160F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 3 misfire count LINCOLN_MIS_CNT_3
- Service 22
DID 1610 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 4 misfire count LINCOLN_MIS_CNT_4
- Service 22
DID 1611 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 5 misfire count LINCOLN_MIS_CNT_5
- Service 22
DID 1612 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 6 misfire count LINCOLN_MIS_CNT_6
- Service 22
DID 1613 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 7 misfire count LINCOLN_MIS_CNT_7
- Service 22
DID 1614 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 8 misfire count LINCOLN_MIS_CNT_8
- Service 22
DID 1615 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder head temperature LINCOLN_CYL_HEAD_T
- Service 22
DID 051D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Cylinder head temperature LINCOLN_CYL_HEAD_T_7E0
- Service 22
DID 1624 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Cylinder head temperature LINCOLN_CYL_HEAD_T_7E0_2
- Service 22
DID F405 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Cylinder head temperature LINCOLN_PCM_CYL_HEAD_T_CORR
- Service 22
DID 0334 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Cylinder head temperature, alternate LINCOLN_CYL_HEAD_T_ALT
- Service 22
DID 1685 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 18415 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Cylinder head temperature, sensor 2 LINCOLN_PCM_CYL_HEAD_T_SENS_2_RAW
- Service 22
DID 05FC - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Diesel exhaust fluid level LINCOLN_DEF_LEVEL
- Service 22
DID 0487 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 63.75 L
- Unit
- L
In testing for 2003 to 2005, 2020 to 2026.
Diesel particulate filter delta pressure LINCOLN_DPF_DELTA_P
- Service 22
DID 116C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 519625 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Diesel particulate filter regen status LINCOLN_DPF_REGEN_STAT
- Service 22
DID 0966 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Diesel particulate filter regeneration status LINCOLN_DPF_REGEN_STAT_F48B
- Service 22
DID F48B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Diesel particulate filter soot level LINCOLN_DPF_SOOT_LEVEL_C974
- Service 22
DID C974 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 73.72
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Diesel particulate filter soot level percentage LINCOLN_DPF_SOOT_LEVEL
- Service 22
DID 042C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -57.14 to 5657 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Diesel particulate filter soot load, variant 2 LINCOLN_DPF_SOOT_LOAD
- Service 22
DID 0579 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Distance since DTC clear LINCOLN_DIST_DTC_CLR
- Service 22
DID F431 - Module
7E0 → 7E8 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Distance since last complete DPF regeneration LINCOLN_DIST_SINCE_COMPLETE_FD8A
- Service 22
DID FD8A - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 653 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Distance with MIL LINCOLN_MIL_DIST
- Service 22
DID F421 - Module
7E0 → 7E8 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
DTC counter LINCOLN_DTC_CNT
- Service 22
DID D137 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Engine load LINCOLN_ENG_LOAD_PCT
Pelican can show this parameter as the engine load.
- Service 22
DID F404 - Module
7E0 → 7E8 - Every
500 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Engine load LINCOLN_MAX_ENG_LOAD_PCT
- Service 22
DID F404 - Module
7E0 → 7E8 - Every
500 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Engine load, actual LINCOLN_ENG_LOAD_ACT
Pelican can show this parameter as the engine load.
- Service 22
DID F443 - Module
7E0 → 7E8 - Every
500 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Engine load, actual LINCOLN_MAX_ENG_LOAD_ACT
- Service 22
DID F443 - Module
7E0 → 7E8 - Every
500 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Engine oil pressure LINCOLN_EOP
- Service 22
DID F45C - Module
7DF - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Engine oil pressure - desired LINCOLN_EOP_DES
- Service 22
DID 05EF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Engine oil temperature LINCOLN_EOT
- Service 22
DID 1310 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Engine oil temperature LINCOLN_EOT_7DF
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID F45C - Module
7DF - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Engine oil temperature LINCOLN_EOT_V2
- Service 22
DID 1310 - Module
7DF - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Engine oil temperature, alternate LINCOLN_EOT_F45C
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID F45C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Engine oil temperature, variant 2 LINCOLN_EOT_VAR_2
- Service 22
DID 1313 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Engine reference torque LINCOLN_PCM_ENG_REFERENCE_TRQ
- Service 22
DID F463 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2003 to 2005, 2020 to 2026.
Engine run time LINCOLN_ERT
- Service 22
DID 1126 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 s
- Unit
- s
In testing for 2003 to 2005, 2020 to 2026.
Engine run time LINCOLN_RUN_TIME
- Service 22
DID F41F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2003 to 2005, 2020 to 2026.
Engine speed LINCOLN_RPM
- Service 22
DID F40C - Module
7E0 → 7E8 - Every
100 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
EV supply equipment type detected LINCOLN_EV_SUP_EQUIPMENT
- Service 22
DID 4851 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Evaporative pressure sensor voltage LINCOLN_EVAP_V
- Service 22
DID 038E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Evaporative pressure sensor, raw count LINCOLN_EVAP_RAW
- Service 22
DID 038E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Evaporative purge LINCOLN_EVAP_PURGE_CMD
- Service 22
DID 1166 - Module
7E0 → 7E8 - Every
500 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Exhaust back pressure LINCOLN_EXH_BACK_P
- Service 22
DID 1445 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2375 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas recirculation LINCOLN_EGR
- Service 22
DID F42C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas recirculation cooler inlet temperature LINCOLN_EGR_COOLER_INLET_T
- Service 22
DID 0569 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1022 to 1022 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas recirculation cooler outlet temperature LINCOLN_EGR_COOLER_OUTLET_T
- Service 22
DID 055D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1022 to 1022 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas recirculation duty cycle LINCOLN_EGR_DUTY
- Service 22
DID 113C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas recirculation inlet temperature LINCOLN_EGR_INLET_T
- Service 22
DID 1161 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 11756 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas recirculation open LINCOLN_EGR_OPEN
- Service 22
DID 052E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas recirculation temperature LINCOLN_EGR_T_7E0
- Service 22
DID F46B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas recirculation temperature LINCOLN_EGR_T_7E0_7E0
- Service 22
DID 0543 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas recirculation temperature a LINCOLN_EGR_T
- Service 22
DID 115F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 11756 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas recirculation throttle position signal LINCOLN_EGR_THROTTLE_POS_SIG
- Service 22
DID 096C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas recirculation valve position measured LINCOLN_EGR_VLV_POS_MEAS
- Service 22
DID 09FE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas recirculation valve position, desired LINCOLN_EGR_VLV_POS_DES
- Service 22
DID 09D2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas temperature 1 LINCOLN_EXH_GAS_T_1
- Service 22
DID 03F4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas temperature 2 LINCOLN_EXH_GAS_T_2
- Service 22
DID 03F5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas temperature after oxidation catalyst, before particulate filter LINCOLN_EGT_PRE_DPF
- Service 22
DID 0992 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 1500 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas temperature after particulate filter LINCOLN_EGT_POST_DPF
- Service 22
DID 1171 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 1500 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas temperature after turbo, before oxidation catalyst LINCOLN_EGT_PRE_DOC
- Service 22
DID 0991 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 1500 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Exhaust gas temperature, bank 1 LINCOLN_EGT_B1
- Service 22
DID F478 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Forward sensing module automatic alignment offset LINCOLN_FSM_AUTOMATIC
- Service 22
DID A220 - Module
764 → 76C - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Fuel pressure sensor voltage, low LINCOLN_LPFP_SENS_V
- Service 22
DID 054D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Fuel pressure, high desired LINCOLN_HPFP_DES
- Service 22
DID 03DC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3500 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Fuel pressure, high desired LINCOLN_MAX_HPFP_DES
- Service 22
DID 03DC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Fuel pressure, low actual LINCOLN_LPFP_ACT
- Service 22
DID 0548 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 200 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Fuel pressure, low desired LINCOLN_LPFP_DES
- Service 22
DID 041F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 110 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Fuel pump duty cycle, low pressure LINCOLN_LPFP_DUTY
- Service 22
DID 0307 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Fuel pump pulse width, bank 1 LINCOLN_FUEL_PMP_WIDTH_BANK_1
- Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Fuel pump pulse width, bank 2 LINCOLN_FUEL_PMP_WIDTH_BANK_2
- Service 22
DID 1142 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Fuel rail sensor voltage, high pressure LINCOLN_HPFP_V
- Service 22
DID 0324 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Fuel trim, long term LINCOLN_LTFT
- Service 22
DID F407 - Module
7E0 → 7E8 - Every
500 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Fuel trim, short term LINCOLN_MAX_STFT
- Service 22
DID F406 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Fuel trim, short term LINCOLN_STFT
Pelican can show this parameter as the short term fuel trim.
- Service 22
DID F406 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Generator coil temperature LINCOLN_GEN_COIL_T
- Service 22
DID 4972 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 11796620 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Generator coil temperature LINCOLN_GEN_COIL_T_7E6
- Service 22
DID 4820 - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -58982 to 58980 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Generator control LINCOLN_GEN_CTRL
- Service 22
DID 0378 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Generator current LINCOLN_GEN_CURRENT
- Service 22
DID 04F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511.8361 to 511.8205 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
Glow plug, commanded status LINCOLN_GLOW_PLUG_CMD_STAT
- Service 22
DID 0416 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -4 to 251
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Grill shutter duty cycle LINCOLN_GRILL_SHUT_DC
- Service 22
DID 0707 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Grill shutter position LINCOLN_GRILL_SHUTTER_POS
- Service 22
DID 0580 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
High voltage battery current LINCOLN_HIGH_V_BAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Service 22
DID 480B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
High voltage current LINCOLN_HIGH_V_CURRENT
- Service 22
DID 480B - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
High voltage leakage resistance bus negative LINCOLN_HIGH_V_LEAKAGE_RES
- Service 22
DID 4812 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kΩ
- Unit
- kΩ
In testing for 2003 to 2005, 2020 to 2026.
High voltage leakage resistance bus overall, raw count LINCOLN_HIGH_V_LEAKAGE_RES_BUS_V2
- Service 22
DID 4813 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
High voltage leakage resistance bus positive LINCOLN_HIGH_V_LEAKAGE_RES_BUS
- Service 22
DID 4811 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kΩ
- Unit
- kΩ
In testing for 2003 to 2005, 2020 to 2026.
High voltage leakage resistance bus positive, raw count LINCOLN_HIGH_V_LEAKAGE_RES_BUS_POSITIVE
- Service 22
DID 4811 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Hydraulic pump motor current LINCOLN_HYDRAULIC_PMP_MOTOR
- Service 22
DID D00F - Module
703 → 70B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
Ignition correction, cylinder 1 LINCOLN_IGN_CORR_CYL1
- Service 22
DID 03EC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -64 to 63.9 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Ignition timing, cylinder 1 LINCOLN_IGN_TIM_CYL1
- Service 22
DID 116B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -80 to 80 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
In car temperature LINCOLN_CAR_T
- Service 22
DID DD04 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 31.875 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Injection control pressure LINCOLN_INJ_CTRL_P
- Service 22
DID 1446 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 37354 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Injection mode LINCOLN_INJ_MODE
- Service 22
DID 046F - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Injection pressure regulator duty cycle LINCOLN_IPR_DUTY
- Service 22
DID 1434 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Injector control module cam and crank sync LINCOLN_FICM_SYNC
- Service 22
DID 09CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Injector control module logic power LINCOLN_FICM_LOGIC_POWER
- Service 22
DID 09CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Injector control module main power LINCOLN_FICM_MAIN_POWER
- Service 22
DID 09D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Injector impulse width LINCOLN_INJ_IMPULSE_WIDTH
- Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.05 s
- Unit
- s
In testing for 2003 to 2005, 2020 to 2026.
Intake air temperature 1 LINCOLN_IAT_1
- Service 22
DID 1123 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Intake air temperature 2 LINCOLN_IAT_2
- Service 22
DID 16A8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -17.77 to 36390 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Intake temperature fault LINCOLN_IAT_FAULT
- Service 22
DID 0700 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Intake temperature sensor voltage LINCOLN_IAT_SENS_V
- Service 22
DID 1279 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Intake temperature, alternate LINCOLN_IAT_ALT2
- Service 22
DID F40F - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Knock counter, cylinder 1 LINCOLN_PCM_CYL_1_KNK_COMB_PERF_CNT
- Service 22
DID 05AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Knock counter, cylinder 2 LINCOLN_PCM_CYL_2_KNK_COMB_PERF_CNT
- Service 22
DID 05AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Knock counter, cylinder 3 LINCOLN_PCM_CYL_3_KNK_COMB_PERF_CNT
- Service 22
DID 05AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Knock counter, cylinder 4 LINCOLN_PCM_CYL_4_KNK_COMB_PERF_CNT
- Service 22
DID 05AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Knock counter, cylinder 5 LINCOLN_PCM_CYL_5_KNK_COMB_PERF_CNT
- Service 22
DID 05B0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Knock counter, cylinder 6 LINCOLN_PCM_CYL_6_KNK_COMB_PERF_CNT
- Service 22
DID 05B1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Knock sensor, 1 LINCOLN_KS1_RAW
- Service 22
DID 0403 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Knock sensor, 2 LINCOLN_KS2_RAW
- Service 22
DID 0404 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Lambda correction LINCOLN_CL_LC
- Service 22
DID 03BD - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -4 to 3.9
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Lambda, commanded LINCOLN_CL
The ratio of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.
- Service 22
DID 030F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.9999
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Leakage resistance bus overall LINCOLN_LEAKAGE_RES_BUS
- Service 22
DID 4813 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kΩ
- Unit
- kΩ
In testing for 2003 to 2005, 2020 to 2026.
Low oil pressure switch LINCOLN_LOW_OIL_P_SWITCH
- Service 22
DID 0416 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Low voltage converter current, high side LINCOLN_LVB_DCDC_HV_CURRENT
- Service 22
DID 483A - Module
746 → 74E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
Manifold absolute pressure, high resolution LINCOLN_MAP_HIRES
- Service 22
DID 0370 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Manifold air temperature LINCOLN_MANIFOLD_AIR_T
- Service 22
DID 16E0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 419 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Manifold pressure LINCOLN_MAP
- Service 22
DID F40B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 36 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Manifold pressure sensor voltage LINCOLN_MAP_V
Typically varies from 1 volt at idle to 5 volts during wide open throttle.
- Service 22
DID 0301 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Manifold temperature LINCOLN_MCT
- Service 22
DID 03CA - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 148.889 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Mass airflow sensor frequency LINCOLN_MASS_AIRFLOW_SENS
- Service 22
DID 033D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 Hz
- Unit
- Hz
In testing for 2003 to 2005, 2020 to 2026.
Misfire acceleration, cylinder 1 LINCOLN_PCM_MISF_ACCEL_CYL1_NORM
- Service 22
DID 0382 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2 to 1.9843
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Misfire acceleration, cylinder 2 LINCOLN_PCM_MISF_ACCEL_CYL2_NORM
- Service 22
DID 0388 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2 to 1.9843
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Misfire acceleration, cylinder 3 LINCOLN_PCM_MISF_ACCEL_CYL3_NORM
- Service 22
DID 038A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2 to 1.9843
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Misfire acceleration, cylinder 4 LINCOLN_PCM_MISF_ACCEL_CYL4_NORM
- Service 22
DID 038B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2 to 1.9843
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Misfire acceleration, cylinder 5 LINCOLN_PCM_MISF_ACCEL_CYL5_NORM
- Service 22
DID 038C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2 to 1.98
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Misfire acceleration, cylinder 6 LINCOLN_PCM_MISF_ACCEL_CYL6_NORM
- Service 22
DID 0398 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2 to 1.9843
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Misfire events, latest cycle LINCOLN_PCM_MISF_EVENTS_LATEST_CYC
- Service 22
DID 0345 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Misfire monitor status LINCOLN_MIS_MON_STAT
- Service 22
DID 03C0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Motor coil temperature LINCOLN_MOTOR_COIL_T
- Service 22
DID 481F - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -58950 to 59012 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Motor electronic coolant temperature II LINCOLN_MOTOR_ELECTRONIC_ECT
- Service 22
DID 4983 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -39.8 to 419 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Motor electronics coolant temperature LINCOLN_MOTOR_ELECTRONICS
- Service 22
DID 4832 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 491 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Navigation altitude LINCOLN_SYNC_GPS_ALTITUDE
- Service 22
DID 8012 - Module
7D0 → 7D8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Navigation heading LINCOLN_SYNC_GPS_HEADING
- Service 22
DID 8012 - Module
7D0 → 7D8 - Every
250 ms - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
O2 sensor voltage, rear LINCOLN_RO2_V
- Service 22
DID 035F - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Octane adjustment LINCOLN_OAR
- Service 22
DID 03E8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Oil life remaining LINCOLN_PCM_ENG_OIL_LIFE_REM
- Service 22
DID 054B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Oil pressure LINCOLN_PCM_ENG_EOP_RAW
- Service 22
DID 0415 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Outdoor temperature, BCM LINCOLN_OUTDOOR_T_BCM
- Service 22
DID DD05 - Module
760 → 768 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Outside temperature LINCOLN_OUTSIDE_T
- Service 22
DID DD05 - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -38 to 421 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Power transfer unit sump temperature LINCOLN_POWER_TRANSFER_UNIT_T
- Service 22
DID 0184 - Module
703 → 70B - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Power transfer unit, requested torque LINCOLN_POWER_TRANSFER_UNIT_REQ_TQ
- Service 22
DID 0182 - Module
703 → 70B - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2003 to 2005, 2020 to 2026.
Power transfer unit, requested torque capacity inferred LINCOLN_POWER_TRANSFER_UNIT_REQ_TQ_CAP
- Service 22
DID 0185 - Module
703 → 70B - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2003 to 2005, 2020 to 2026.
Secondary motor torque, commanded LINCOLN_SECONDARY_MOTOR_TQ_CMD
- Service 22
DID 4819 - Module
7E7 → 7EF - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2003 to 2005, 2020 to 2026.
Steering angle from the body module, actual value LINCOLN_BCM_STEER_ANG_ACT
- Service 22
DID 3302 - Module
760 → 768 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -780 to 5773 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Steering shaft torque LINCOLN_STEER_SHFT_TQ
- Service 22
DID 330C - Module
730 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -12.7 to 12.8 N·m
- Unit
- N·m
In testing for 2003 to 2005, 2020 to 2026.
Sump oil temperature measured LINCOLN_SUMP_OIL_T_MEAS
- Service 22
DID 03F3 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Temperature inside car LINCOLN_T_INSIDE_CAR
- Service 22
DID DD04 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 419 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Throttle angle, actual LINCOLN_ETC_ANG_ACT
- Service 22
DID 093C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 127.99 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Throttle angle, desired LINCOLN_ETC_ANG_DES
- Service 22
DID 091A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 127.99 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Throttle control trim angle, learned LINCOLN_ETC_TRIM_LRN
- Service 22
DID 0338 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -64 to 63.9 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Throttle inlet pressure LINCOLN_TIP_ABS
- Service 22
DID 033E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 60 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Throttle inlet pressure sensor voltage LINCOLN_TIP_V
- Service 22
DID 033C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Throttle inlet pressure, desired LINCOLN_TIP_DES_ABS
- Service 22
DID 0466 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 72.5 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Time since last oil change LINCOLN_TIME_SINCE_OIL
- Service 22
DID 053F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000
- Unit
- Raw value
In testing for 2003 to 2005, 2020 to 2026.
Torque converter slip LINCOLN_TQ_CONV_SLIP
- Service 22
DID 11B8 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 39996.0104 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
Torque into torque converter LINCOLN_TQ_INTO_TQ_CONV
- Service 22
DID 09CB - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 48336.1353 N·m
- Unit
- N·m
In testing for 2003 to 2005, 2020 to 2026.
Torque into torque converter LINCOLN_TQ_INTO_TQ_CONV_7E0
- Service 22
DID 163A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 69.1467 N·m
- Unit
- N·m
In testing for 2003 to 2005, 2020 to 2026.
Torque request LINCOLN_TRQ_CTRL_REQ
- Service 22
DID 03AF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Total misfire count LINCOLN_TOT_MIS_CNT
- Service 22
DID 1616 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Transfer case fluid temperature LINCOLN_TRANSFER_CASE_FLUID_T
- Service 22
DID 070D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Transmission fluid temperature, variant 1 LINCOLN_ATF_T_VAR_1
- Service 22
DID 1674 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 8191 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Transmission fluid temperature, variant 2 LINCOLN_ATF_T_VAR_2
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1674 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Transmission fluid temperature, variant 5 LINCOLN_ATF_T_VAR_5
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1E3F - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Transmission fluid temperature, variant 6 LINCOLN_ATF_T_VAR_6
- Service 22
DID 092C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °F
- Unit
- °F
In testing for 2003 to 2005, 2020 to 2026.
Transmission oil temperature LINCOLN_TOT_7E0
- Service 22
DID 1E1C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -500 to 500 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Turbo boost LINCOLN_TURBO_BOOST
- Service 22
DID 09DB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Turbo inlet pressure LINCOLN_TURBO_INLET_P
- Service 22
DID 05BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Variable geometry turbo duty cycle LINCOLN_VGT_DUTY
- Service 22
DID 096D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Warm-ups since DTC clear LINCOLN_WARMUP_CLR
- Service 22
DID F430 - Module
7E0 → 7E8 - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Wastegate control LINCOLN_WASTEGATE_CTRL
- Service 22
DID 16E1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Wastegate duty cycle LINCOLN_WGDC
- Service 22
DID 0462 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Yaw rate signal LINCOLN_YAW_RATE_SIG
- Service 22
DID 2B0B - Module
760 → 768 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553 to 6553
- Unit
- Raw value
In testing for 2003 to 2005, 2020 to 2026.
Fuel
Air/fuel ratio LINCOLN_AIR_FUEL_RAT
- Service 22
DID F434 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.2801
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 1 fuel balance correction LINCOLN_CYL_1_FUEL_BALANCE
- Service 22
DID 098A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 1 fuel quantity LINCOLN_CYL_1_FUEL_QTY
- Service 22
DID 04AA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 2 fuel balance correction LINCOLN_CYL_2_FUEL_BALANCE
- Service 22
DID 098B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 2 fuel quantity LINCOLN_CYL_2_FUEL_QTY
- Service 22
DID 04AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 3 fuel balance correction LINCOLN_CYL_3_FUEL_BALANCE
- Service 22
DID 098C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 3 fuel quantity LINCOLN_CYL_3_FUEL_QTY
- Service 22
DID 04AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 4 fuel balance correction LINCOLN_CYL_4_FUEL_BALANCE
- Service 22
DID 098D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 4 fuel quantity LINCOLN_CYL_4_FUEL_QTY
- Service 22
DID 04AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 5 fuel balance correction LINCOLN_CYL_5_FUEL_BALANCE
- Service 22
DID 11D3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 5 fuel quantity LINCOLN_CYL_5_FUEL_QTY
- Service 22
DID 04AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 6 fuel balance correction LINCOLN_CYL_6_FUEL_BALANCE
- Service 22
DID 048F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 6 fuel quantity LINCOLN_CYL_6_FUEL_QTY
- Service 22
DID 04AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 7 fuel balance correction LINCOLN_CYL_7_FUEL_BALANCE
- Service 22
DID 04A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 7 fuel quantity LINCOLN_CYL_7_FUEL_QTY
- Service 22
DID 04B0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 8 fuel balance correction LINCOLN_CYL_8_FUEL_BALANCE
- Service 22
DID 04A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Cylinder 8 fuel quantity LINCOLN_CYL_8_FUEL_QTY
- Service 22
DID 04B1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -65.53 to 65.53
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Dilution of oil with fuel LINCOLN_DILUTION_OIL_FUEL
- Service 22
DID 054C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Engine fuel rate LINCOLN_ENG_FUEL_RATE
- Service 22
DID F45E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L
- Unit
- L
In testing for 2003 to 2005, 2020 to 2026.
Fuel correction, cylinder 1 LINCOLN_FUEL_CORR_CYL_1
- Service 22
DID 098A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 2003 to 2005, 2020 to 2026.
Fuel correction, cylinder 2 LINCOLN_FUEL_CORR_CYL_2
- Service 22
DID 098B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 2003 to 2005, 2020 to 2026.
Fuel correction, cylinder 3 LINCOLN_FUEL_CORR_CYL_3
- Service 22
DID 098C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 2003 to 2005, 2020 to 2026.
Fuel correction, cylinder 4 LINCOLN_FUEL_CORR_CYL_4
- Service 22
DID 098D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 2003 to 2005, 2020 to 2026.
Fuel correction, cylinder 5 LINCOLN_FUEL_CORR_CYL_5
- Service 22
DID 11D3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 2003 to 2005, 2020 to 2026.
Fuel correction, cylinder 6 LINCOLN_FUEL_CORR_CYL_6
- Service 22
DID 048F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383
- Unit
- Raw value
In testing for 2003 to 2005, 2020 to 2026.
Fuel injection impulse width LINCOLN_FUEL_INJ_IMPULSE
- Service 22
DID 168B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.1 s
- Unit
- s
In testing for 2003 to 2005, 2020 to 2026.
Fuel level LINCOLN_FLI
Pelican can show this parameter as the fuel tank level.
- Service 22
DID F42F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Fuel level LINCOLN_FLI_16C1
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 16C1 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Fuel pulse width LINCOLN_FUEL_WIDTH
- Service 22
DID 1410 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 524 ms
- Unit
- ms
In testing for 2003 to 2005, 2020 to 2026.
Fuel pump duty cycle LINCOLN_FUEL_PMP_DUTY
- Service 22
DID 1672 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 199.2187 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Fuel rail pressure control LINCOLN_FUEL_RAIL_P_CTRL
- Service 22
DID 03C3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Fuel tank level LINCOLN_FLI_V2
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 6185 - Module
720 → 728 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Fuel tank pressure LINCOLN_FUEL_TANK_P
- Service 22
DID 1639 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9496.0214 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Fuel temperature LINCOLN_FUEL_T
- Service 22
DID 0522 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Fuel temperature a LINCOLN_FUEL_T_7E0
- Service 22
DID 0429 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Low side fuel rail pressure LINCOLN_LOW_SIDE_FUEL_RAIL_P
- Service 22
DID 064E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Mass fuel, desired LINCOLN_MASS_FUEL_DES
- Service 22
DID 1412 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Volume fuel, desired LINCOLN_VOLUME_FUEL_DES
- Service 22
DID 1411 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Lights
Exterior lighting state LINCOLN_EXTERIOR_LIGHT_STATE
- Service 22
DID 407E - Module
726 → 72E - Every
1 s - Testing
Bit 0 of the reply.
- Unit
- Named states
| Raw value | State |
|---|---|
0 | 0 |
216 | 1 |
In testing for 2003 to 2005, 2020 to 2026.
High beam status LINCOLN_HIGH_BEAM
- Service 22
DID 7151 - Module
726 → 72E - Every
4 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
LINCOLN
Accelerator Pedal Position LINCOLN_[ECU] Accelerator pedal position
- Service 22
DID 032B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Air conditioning compressor pressure LINCOLN_[ECU] AC Pressure
- Service 22
DID 0393 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -100 to 1000 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Ambient air temperature sensor voltage LINCOLN_[ECU] AAT Sensor V
- Service 22
DID 03BA - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Barometric pressure LINCOLN_[ECU] Baro
- Service 22
DID 0353 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 8 to 20 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Barometric pressure sensor voltage LINCOLN_[ECU] Baro Sensor V
- Service 22
DID 035A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Closed loop lambda correction LINCOLN_[ECU] CL Lambda Corr
- Service 22
DID 03BD - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -4 to 3.99
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Commanded lambda LINCOLN_[ECU] Commanded lambda
The ratio of of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.
- Service 22
DID 030F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Engine coolant temperature LINCOLN_[ECU] ECT
- Service 22
DID 038F - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 148.889 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
High pressure fuel rail sensor voltage LINCOLN_[ECU] HPFP sensor voltage
- Service 22
DID 0324 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Low pressure fuel pump commanded duty cycle LINCOLN_[ECU] LPFP duty cycle
- Service 22
DID 0307 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Manifold absolute pressure sensor voltage LINCOLN_[ECU] MAP voltage
Typically varies from 1 volt at idle to 5 volts during wide open throttle.
- Service 22
DID 0301 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Octane adjust ratio LINCOLN_[ECU] OAR
- Service 22
DID 03E8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1 to 1
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Rear O2 voltage LINCOLN_[ECU] Rear O2 V
- Service 22
DID 035F - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Throttle inlet pressure absolute LINCOLN_[ECU] TIP actual abs
- Service 22
DID 033E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 60 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Throttle inlet pressure sensor voltage LINCOLN_[ECU] TIP sensor voltage
- Service 22
DID 033C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
VCT exhaust cam desired LINCOLN_[ECU] VCT Exh Des
- Service 22
DID 03BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 50 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
VCT exhaust camshaft actual LINCOLN_[ECU] VCT exhaust actual
- Service 22
DID 0319 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -50 to 50 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
VCT exhaust camshaft error LINCOLN_[ECU] VCT exhaust error
- Service 22
DID 031B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -50 to 50 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
VCT exhaust camshaft solenoid duty cycle LINCOLN_[ECU] VCT exhaust duty cycle
- Service 22
DID 0317 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
VCT intake cam desired LINCOLN_[ECU] VCT Int Des
- Service 22
DID 03BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -50 to 40 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
VCT intake camshaft actual LINCOLN_[ECU] VCT intake actual
- Service 22
DID 0318 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -50 to 50 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
VCT intake camshaft solenoid duty cycle LINCOLN_[ECU] VCT intake duty cycle
- Service 22
DID 0316 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
LINCOLN_ETC_TRIM
Electronic throttle control learned trim angle LINCOLN_ETC_TRIM_LEARNED
- Service 22
DID 0338 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -63.9 to 64 °
- Unit
- °
In testing for 2003 to 2005, 2020 to 2026.
Movement
Accelerator pedal position LINCOLN_ACCEL_PEDAL_POS
- Service 22
DID 09D4 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Actual output shaft speed LINCOLN_ACT_OUTPUT_SHFT_SPD
- Service 22
DID 1E1B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
Actual turbine shaft speed LINCOLN_ACT_TURBINE_SHFT_SPD
- Service 22
DID 1E13 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
Coolant pump a control speed, commanded LINCOLN_CLT_PMP_CTRL_SPD_CMD
- Service 22
DID 011A - Module
7E4 → 7EC - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Coolant pump b control speed, commanded LINCOLN_CLT_PMP_B_CTRL_SPD_CMD
- Service 22
DID 0117 - Module
7E4 → 7EC - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 V
- Unit
- V
In testing for 2003 to 2005, 2020 to 2026.
Fan speed demanded LINCOLN_FAN_SPD_DEMANDED
- Service 22
DID 0701 - Module
7E4 → 7EC - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
Fan speed indicated LINCOLN_FAN_SPD_INDICATED
- Service 22
DID 0702 - Module
7E4 → 7EC - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
Fan speed sensor LINCOLN_FAN_SPD_SENS
- Service 22
DID 099F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
Fan speed, desired LINCOLN_FAN_SPD_DES
- Service 22
DID 03B9 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Front left wheel speed LINCOLN_FL_VSS
- Service 22
DID 2B07 - Module
760 → 768 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Front right wheel speed LINCOLN_FR_VSS
- Service 22
DID 2B06 - Module
760 → 768 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Lateral acceleration LINCOLN_LAT_G
- Service 22
DID 2B11 - Module
760 → 768 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1 to 1
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Lateral angle, raw count LINCOLN_LAT_ANG
- Service 22
DID 2B0C - Module
760 → 768 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Navigation speed LINCOLN_SYNC_GPS_SPD
- Service 22
DID 8012 - Module
7D0 → 7D8 - Every
250 ms - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
- Range
- 0 to 235926 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Power transfer unit input shaft speed LINCOLN_POWER_TRANSFER_UNIT
- Service 22
DID 017E - Module
703 → 70B - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
Rear left wheel speed LINCOLN_RL_VSS
- Service 22
DID 2B09 - Module
760 → 768 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Rear right wheel speed LINCOLN_RR_VSS
- Service 22
DID 2B08 - Module
760 → 768 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Traction motor speed LINCOLN_TRACTION_MOTOR_SPD
- Service 22
DID 496A - Module
7E4 → 7EC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
Vehicle speed LINCOLN_MAX_VSS
- Service 22
DID F40D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Vehicle speed LINCOLN_VSS
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Vehicle speed, high resolution LINCOLN_VSS_HD
- Service 22
DID 1505 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 200 km/h
- Unit
- km/h
In testing for 2003 to 2005, 2020 to 2026.
Tires
4 wheel drive engaged LINCOLN_4_WHL_DRIVE_ENGAGED
- Service 22
DID A211 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Front left tire pressure LINCOLN_MAX_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 2813 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 150 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Front left tire pressure LINCOLN_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 2813 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Front right tire pressure LINCOLN_MAX_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 2814 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 150 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Front right tire pressure LINCOLN_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 2814 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Rear left inner tire pressure LINCOLN_TP_RLI
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 2818 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Rear left inner tire pressure slot LINCOLN_TP_RLI_RAW
A rear inner tire position, which this car does not have. Raw count; dual-wheel trucks read it at 1/20 psi.
- Service 22
DID 2818 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Rear left outer tire pressure LINCOLN_MAX_TP_RLO
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 2816 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 150 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Rear left outer tire pressure LINCOLN_TP_RLO
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 2816 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Rear left tire pressure LINCOLN_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 2816 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Rear right inner tire pressure LINCOLN_TP_RRI
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 2817 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Rear right inner tire pressure slot LINCOLN_TP_RRI_RAW
A rear inner tire position, which this car does not have. Raw count; dual-wheel trucks read it at 1/20 psi.
- Service 22
DID 2817 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Rear right outer tire pressure LINCOLN_MAX_TP_RRO
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 2815 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 150 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Rear right outer tire pressure LINCOLN_TP_RRO
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 2815 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Rear right tire pressure LINCOLN_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 2815 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Tire pressure warning indicator LINCOLN_TPMS_WARN
- Service 22
DID 61A5 - Module
720 → 728 - Every
15 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2005, 2020 to 2026.
Tire pressure, rear left inner LINCOLN_MAX_TP_RLI
- Service 22
DID 2818 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 150 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Tire pressure, rear right inner LINCOLN_MAX_TP_RRI
- Service 22
DID 2817 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 150 psi
- Unit
- psi
In testing for 2003 to 2005, 2020 to 2026.
Tire temperature LINCOLN_MAX_TYRE_T
- Service 22
DID 280B - Module
726 → 72E - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Tire temperature LINCOLN_TYRE_T
- Service 22
DID 280B - Module
726 → 72E - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Transmission
Actual torque converter slip LINCOLN_ACT_TQ_CONV_SLIP
- Service 22
DID 1E14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
All-wheel drive clutch diagnostic signal LINCOLN_AWD_CLU_DIAGNOSTIC
- Service 22
DID 1E62 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
All-wheel drive clutch, commanded control signal LINCOLN_AWD_CLU_CMD_CTRL_SIG
- Service 22
DID 1E63 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2005, 2020 to 2026.
Axle gear ratio, measured LINCOLN_AXLE_GEAR_RATIO_MEAS
- Service 22
DID 1E16 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 10
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Converter speed ratio LINCOLN_CONV_SPD_RAT
- Service 22
DID 11BA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3996.0365
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Current gear LINCOLN_GEAR
The automatic transmission gear.
- Service 22
DID 1E12 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
9 | 9 | Ninth gear |
10 | 10 | Tenth gear |
In testing for 2003 to 2005, 2020 to 2026.
Desired torque converter slip LINCOLN_DES_TQ_CONV_SLIP
- Service 22
DID 1E35 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
Gear LINCOLN_GEAR_7E1
- Service 22
DID 1E1F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Gear commanded LINCOLN_GEAR_CMD
- Service 22
DID 1E12 - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | UNKNOWN | Unknown |
20 | L | |
40 | D | |
50 | N | |
60 | R | |
70 | P | |
255 | FAULT | Fault |
In testing for 2003 to 2005, 2020 to 2026.
Gear ratio, commanded LINCOLN_PCM_CMD_TRANS_GEAR_RATIO
- Service 22
DID 1E19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Gear, engaged LINCOLN_GEAR_ENG
- Service 22
DID 1E1F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Measured current of clutch a actuator LINCOLN_MEAS_CURRENT_CLU
- Service 22
DID 1E9E - Module
703 → 70B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
Shift gear LINCOLN_GEAR_SHFT
- Service 22
DID 1E23 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
10 | MANUAL | Manual |
46 | DRIVE | Drive |
50 | NEUTRAL | Neutral |
60 | REVERSE | Reverse |
70 | PARK | Park |
In testing for 2003 to 2005, 2020 to 2026.
Shift gear LINCOLN_GEAR_SHFT_V2
- Service 22
DID 1E23 - Module
7DF - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Shift gear LINCOLN_GEAR_SHFT_V2_7DF
Selected range. Neutral, reverse and park are mapped; the code driving reports (43) is not yet.
- Service 22
DID 1E23 - Module
7DF - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
50 | NEUTRAL | Neutral |
60 | REVERSE | Reverse |
70 | PARK | Park |
In testing for 2003 to 2005, 2020 to 2026.
Torque converter line pressure LINCOLN_TQ_CONV_LINE_P
- Service 22
DID 11C0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8790.819 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Torque into torque converter, variant 2 LINCOLN_TQ_INTO_TQ_CONV_VAR_2
- Service 22
DID 163A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 69.1467 N·m
- Unit
- N·m
In testing for 2003 to 2005, 2020 to 2026.
Transmission fluid fluid quality LINCOLN_TRANS_FLUID_FLUID
- Service 22
DID 180F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Transmission gear LINCOLN_TRANS_GEAR
- Service 22
DID 11B3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Transmission gear LINCOLN_TRANS_GEAR_7E1
- Service 22
DID 11B3 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Transmission gear ratio LINCOLN_TRANS_GEAR_RAT
- Service 22
DID 163B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 4015.748
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Transmission odometer LINCOLN_TRANS_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Transmission oil temperature LINCOLN_TOT
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1E1C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 255 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Transmission oil temperature LINCOLN_TOT_V2
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1E1C - Module
7DF → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -500 to 500 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Transmission output shaft speed LINCOLN_TRANS_OUTPUT_SHFT
- Service 22
DID 11B5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1638.375 rpm
- Unit
- rpm
In testing for 2003 to 2005, 2020 to 2026.
Transmission pressure, commanded LINCOLN_PCM_CMD_TRANS_MAIN_LINE_P
- Service 22
DID 1E1A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534 kPa
- Unit
- kPa
In testing for 2003 to 2005, 2020 to 2026.
Transmission temperature LINCOLN_TT
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1E1C - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -300 to 300 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Trips
Battery current, high range LINCOLN_CURRENT_HIGH_RANGE
- Service 22
DID 4809 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
Distance since last complete regeneration LINCOLN_DIST_SINCE_COMPLETE
- Service 22
DID 0434 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 4026531 mi
- Unit
- mi
In testing for 2003 to 2005, 2020 to 2026.
Distance since last oil change LINCOLN_DIST_SINCE_OIL
- Service 22
DID 0542 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Distance to empty, calculated LINCOLN_DTE
Pelican can show this parameter as the fuel range.
- Service 22
DID 4194 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Distance to empty, displayed LINCOLN_DTE_DISP
Pelican can show this parameter as the fuel range.
- Service 22
DID 4195 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
HV battery current, low range LINCOLN_HVB_CURRENT_LOW
- Service 22
DID 480A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 A
- Unit
- A
In testing for 2003 to 2005, 2020 to 2026.
Maximum battery temperature LINCOLN_HVBAT_T_MAX
- Service 22
DID 4808 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Minimum battery temperature LINCOLN_HVBAT_T_MIN
- Service 22
DID 4808 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2005, 2020 to 2026.
Odometer LINCOLN_BECM_ODO
- Service 22
DID 6182 - Module
7E4 → 7EC - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 536
- Unit
- Number
In testing for 2003 to 2005, 2020 to 2026.
Odometer LINCOLN_IPC_ODO
- Service 22
DID 404C - Module
720 → 728 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 1677721 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Odometer LINCOLN_MAX_ODO_7E0
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Odometer LINCOLN_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Odometer LINCOLN_ODO_720
- Service 22
DID 6180 - Module
720 → 728 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 1677721 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Odometer LINCOLN_ODO_7E0
- Service 22
DID DD01 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Odometer LINCOLN_ODO_V2
Pelican can show this parameter as the odometer.
- Service 22
DID 404C - Module
720 → 728 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 1677721 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Odometer, battery control module LINCOLN_ODO_BCM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
760 → 768 - Every
5 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Odometer, brake module LINCOLN_ABS_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
760 → 768 - Every
5 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Odometer, forward sensing module LINCOLN_ODO_FSM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
764 → 76C - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Odometer, instrument panel LINCOLN_MAX_ODO_726
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
726 → 72E - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Odometer, instrument panel LINCOLN_ODO_726
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
726 → 72E - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Odometer, power steering module LINCOLN_ODO_PSCM
Pelican can show this parameter as the odometer.
- Service 22
DID DD01 - Module
730 → 738 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Total distance, lifetime LINCOLN_TOT_DIST_LIFETIME
- Service 22
DID F817 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Trip distance LINCOLN_ODO_TRIP
- Service 22
DID DD01 - Module
720 → 728 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 1677721 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.
Vehicle odometer LINCOLN_PCM_VEH_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID F4A6 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
In testing for 2003 to 2005, 2020 to 2026.