Parameters
The Lexus UX has 723 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
+BM voltage UX_BM_V
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
1st turbocharger outlet pressure, control valve UX_1ST_TRUBOCHARGER_P
- Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
2nd turbocharger outlet pressure UX_2ND_TRUBOCHARGER_OUTLET_P
- Service 22
DID 11AF - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
2nd turbocharger outlet pressure, control valve UX_2ND_TRUBOCHARGER_P
- Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
12V battery current UX_12V_CConfirmed
- Service 22
DID 15F7 - Module
7D2 → 7DA - Every
500 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -125 to 124 A
- Unit
- A
0x7417 = 29719 → = -11.630931 A
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
12V battery temperature UX_12V_TConfirmed
- Service 22
DID 15F8 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x0126 = 294 → = -10.6 °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
12V battery voltage UX_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 15EE - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 80.2 V
- Unit
- V
0x27 = 39 → = 12.27722 V
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
12V battery voltage before system main relay UX_12V_BAT_V_BEFORE_SMRConfirmed
- Service 22
DID 107E - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 11.56 V
- Unit
- V
0x23 = 35 → = 11.2927 V
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
12V battery voltage smoothed UX_12V_BAT_V_SMOOTHEDConfirmed
- Service 22
DID 1F42 - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
0x2DDF = 11743 → = 11.743 V
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Aux battery voltage UX_AUX_BAT_VConfirmed
- Service 22
DID 1002 - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.95 V
- Unit
- V
0x2838 = 10296 → = 12.56112 V
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Aux. battery capacity after IG OFF UX_AUX_BAT_CAP_AFTER_IG_OFF
- Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Aux. battery capacity after IG ON UX_AUX_BAT_CAP_AFTER_IG_ON
- Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Auxiliary battery current UX_AUXILIARY_BATConfirmed
- Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -12500 to -12451 A
- Unit
- A
0x00 = 0 → = -12,500 A
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Battery current UX_BAT_CURRENT
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery current UX_BAT_CURRENT_700
- Service 22
DID 15F7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery heater temperature UX_BAT_HEATER_T
- Service 22
DID 1824 - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery status of full charge UX_BAT_STAT_FULL_CHG
- Service 22
DID 15E5 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 32512.5 Ah
- Unit
- Ah
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature UX_BAT_T
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6513.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature UX_BAT_T_700
- Service 22
DID 15F8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature UX_BAT_T_700_2
- Service 22
DID 1FF8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 01 UX_BAT_T_01
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 02 UX_BAT_T_02
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 03 UX_BAT_T_03
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 04 UX_BAT_T_04
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 05 UX_BAT_T_05
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 06 UX_BAT_T_06
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 07 UX_BAT_T_07
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 08 UX_BAT_T_08
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 09 UX_BAT_T_09
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 10 UX_BAT_T_10
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 11 UX_BAT_T_11
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 12 UX_BAT_T_12
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 13 UX_BAT_T_13
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 14 UX_BAT_T_14
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 15 UX_BAT_T_15
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature 16 UX_BAT_T_16
- Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery voltage UX_12V_V_700Confirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 1002 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 79 V
- Unit
- V
0x25C0 = 9664 → = 11.796845 V
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Battery voltage UX_BAT_V
- Service 21
PID 13 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Battery voltage UX_BATTERY_VOLTAGE_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Charge contactor current UX_SCC_SOLENOID_CURRENTConfirmed
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
0x00 = 0 → 0 mA
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Charging integrated current of aux. battery UX_CHG_INTEGRATED
- Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Dark current of battery UX_DARK_CURRENT_BAT
- Service 22
DID 15E7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
DC-DC converter high side voltage UX_DC_DC_CONV_HIGH_SIDE_V
- Service 22
DID 111E - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7999 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
DC-DC converter low side voltage UX_DC_DC_CONV_LOW_SIDE_V
- Service 22
DID 111D - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 19.92 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
DC-DC converter, target voltage before charging UX_DC_DC_CONV_TGT_V
- Service 22
DID 111F - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7999 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Discharging integrated current of aux. battery UX_DISCHARGING
- Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Distance since last battery cable disconnection UX_DIST_SINCE_BAT_DISCConfirmed
- Service 22
DID 106C - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x7F0E = 32526 → 32,526 km
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
HV battery charge voltage UX_HVBAT_CHRG_V
- Service 22
DID 1609 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
HV battery charge, maximum UX_HVBAT_SOC_MAXConfirmed
- Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x5B = 91 → = 45.5 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
HV battery charge, minimum UX_HVBAT_SOC_MINConfirmed
- Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x3B = 59 → = 29.5 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
HV battery current UX_HVBAT_CConfirmed
- Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 A
- Unit
- A
0x0577 = 1399 → = 139.9 A
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
HV battery maximum temperature UX_HVBAT_MAX_T
- Service 22
DID 1829 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
HV battery minimum temperature UX_HVBAT_MIN_T
- Service 22
DID 182A - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
HV battery voltage UX_HVBAT_VConfirmed
- Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 V
- Unit
- V
0x3300 = 13056 → = 204 V
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Hybrid battery 1 fan UX_HYBRID_BAT_1_FANConfirmed
- Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Hybrid battery 1 fan UX_HYBRID_BAT_1_FAN_747
- Service 22
DID 1802 - Module
747 → 74F - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Hybrid battery block 1 average voltage UX_HYBRID_BAT_BLOCK_1_V
- Service 22
DID 1819 - Module
747 → 74F - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 °F
- Unit
- °F
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Hybrid battery block 2 average voltage UX_HYBRID_BAT_BLOCK_2_V
- Service 22
DID 1819 - Module
747 → 74F - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 °F
- Unit
- °F
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Hybrid battery block 3 average voltage UX_HYBRID_BAT_BLOCK_3_V
- Service 22
DID 1819 - Module
747 → 74F - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 °F
- Unit
- °F
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Hybrid battery block 4 average voltage UX_HYBRID_BAT_BLOCK_4_V
- Service 22
DID 1819 - Module
747 → 74F - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 °F
- Unit
- °F
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Hybrid battery block 5 average voltage UX_HYBRID_BAT_BLOCK_5_V
- Service 22
DID 1819 - Module
747 → 74F - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 °F
- Unit
- °F
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Hybrid battery current UX_HYBRID_BAT_CURRENT
- Service 22
DID 1F9A - Module
747 → 74F - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Hybrid battery heater temperature 2 UX_HYBRID_BAT_HEATER_T_2
- Service 22
DID 1825 - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Hybrid battery intake air temperature 1 UX_HYBRID_BAT_IAT_1
- Service 22
DID 180B - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Hybrid battery intake air temperature 2 UX_HYBRID_BAT_IAT_2
- Service 22
DID 180B - Module
747 → 74F - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Hybrid battery SOC UX_HYBRID_BAT_SOC
- Service 22
DID 1F5B - Module
747 → 74F - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Hybrid battery temperature 1 UX_HYBRID_BAT_T_1Confirmed
- Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -58 to 400 °F
- Unit
- °F
0x3E61 = 15969 → = 53.601465 °F
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Hybrid battery temperature 2 UX_HYBRID_BAT_T_2Confirmed
- Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -58 to 401 °F
- Unit
- °F
0x3E = 62 → = 53.6 °F
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Hybrid battery temperature 3 UX_HYBRID_BAT_T_3Confirmed
- Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -58 to 400 °F
- Unit
- °F
0x3E97 = 16023 → = 53.978851 °F
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Hybrid battery voltage UX_HYBRID_BAT_V
- Service 22
DID F19A - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Hybrid battery voltage UX_HYBRID_BAT_V_747
- Service 22
DID F19A - Module
747 → 74F - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Initial engine battery voltage lower limit UX_INITIAL_ENG_BAT_V_LO
- Service 22
DID 15F6 - Module
700 → 708 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Main connector solenoid current UX_SMC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2019 to 2022, 2024, 2026. Supported for 2023. Not supported for 2025.
Main relay a, solenoid current UX_SLA_SOLENOID_CURRENTConfirmed
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
0x00 = 0 → 0 mA
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Main relay r solenoid current UX_SLR_SOLENOID_CURRENTConfirmed
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
0x00 = 0 → 0 mA
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Output speed sensor voltage UX_NOUT_SENS_V
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Regen cooperation UX_REGEN_COOPERATIONConfirmed
- Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Regenerative operation UX_FR_REGEN_OPERATIONConfirmed
- Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
0x0000 = 0 → 0 N·m
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Regenerative request UX_FR_REGEN_REQUESTConfirmed
- Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
0x0000 = 0 → 0 N·m
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Relay control solenoid current UX_SRC_SOLENOID_CURRENT
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2019 to 2022, 2024, 2026. Supported for 2023. Not supported for 2025.
Service contactor solenoid current UX_SSC_SOLENOID_CURRENTConfirmed
- Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
0x00 = 0 → 0 mA
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Sleep time of battery sensor UX_SLEEP_TIME_BATSENS
- Service 22
DID 15F0 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 h
- Unit
- h
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
State of charge UX_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID 1F5B - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x4C = 76 → = 29.803922 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Turbine speed sensor voltage UX_NT_SENS_V
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Vh-voltage after boosting UX_VH_V_AFTER_BOOSTINGConfirmed
- Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 V
- Unit
- V
0x0513 = 1299 → = 649.5 V
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Vl-voltage before boosting UX_VL_V_BEFORE_BOOSTINGConfirmed
- Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 V
- Unit
- V
0x018F = 399 → = 199.5 V
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Voltage of battery sensor UX_V_BATSENS
- Service 22
DID 15EE - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.9979 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Cells
HV battery cell #01 voltage UX_HVBAT_C01_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #02 voltage UX_HVBAT_C02_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xAE6A = 44650 → = 3.406577 V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #03 voltage UX_HVBAT_C03_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #04 voltage UX_HVBAT_C04_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #05 voltage UX_HVBAT_C05_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #06 voltage UX_HVBAT_C06_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #07 voltage UX_HVBAT_C07_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #08 voltage UX_HVBAT_C08_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #09 voltage UX_HVBAT_C09_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #10 voltage UX_HVBAT_C10_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #11 voltage UX_HVBAT_C11_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #12 voltage UX_HVBAT_C12_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #13 voltage UX_HVBAT_C13_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #14 voltage UX_HVBAT_C14_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #15 voltage UX_HVBAT_C15_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #16 voltage UX_HVBAT_C16_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #17 voltage UX_HVBAT_C17_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #18 voltage UX_HVBAT_C18_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #19 voltage UX_HVBAT_C19_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #20 voltage UX_HVBAT_C20_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #21 voltage UX_HVBAT_C21_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #22 voltage UX_HVBAT_C22_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #23 voltage UX_HVBAT_C23_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #24 voltage UX_HVBAT_C24_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #25 voltage UX_HVBAT_C25_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #26 voltage UX_HVBAT_C26_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #27 voltage UX_HVBAT_C27_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #28 voltage UX_HVBAT_C28_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xAE6A = 44650 → = 3.406577 V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #29 voltage UX_HVBAT_C29_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xAE6A = 44650 → = 3.406577 V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #30 voltage UX_HVBAT_C30_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #31 voltage UX_HVBAT_C31_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #32 voltage UX_HVBAT_C32_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #33 voltage UX_HVBAT_C33_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xAE6A = 44650 → = 3.406577 V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #34 voltage UX_HVBAT_C34_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #35 voltage UX_HVBAT_C35_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 544 to 559 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xAE6A = 44650 → = 3.406577 V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #36 voltage UX_HVBAT_C36_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 560 to 575 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #37 voltage UX_HVBAT_C37_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 576 to 591 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #38 voltage UX_HVBAT_C38_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 592 to 607 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #39 voltage UX_HVBAT_C39_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 608 to 623 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #40 voltage UX_HVBAT_C40_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 624 to 639 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #41 voltage UX_HVBAT_C41_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 640 to 655 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #42 voltage UX_HVBAT_C42_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 656 to 671 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xAE6A = 44650 → = 3.406577 V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #43 voltage UX_HVBAT_C43_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 672 to 687 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xAE6A = 44650 → = 3.406577 V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #44 voltage UX_HVBAT_C44_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 688 to 703 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #45 voltage UX_HVBAT_C45_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 704 to 719 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #46 voltage UX_HVBAT_C46_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 720 to 735 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #47 voltage UX_HVBAT_C47_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 736 to 751 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #48 voltage UX_HVBAT_C48_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 752 to 767 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #49 voltage UX_HVBAT_C49_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 768 to 783 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xAE2B = 44587 → = 3.40177 V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #50 voltage UX_HVBAT_C50_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 784 to 799 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #51 voltage UX_HVBAT_C51_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 800 to 815 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #52 voltage UX_HVBAT_C52_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 816 to 831 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xAE2B = 44587 → = 3.40177 V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #53 voltage UX_HVBAT_C53_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 832 to 847 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #54 voltage UX_HVBAT_C54_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 848 to 863 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #55 voltage UX_HVBAT_C55_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 864 to 879 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #56 voltage UX_HVBAT_C56_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 880 to 895 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
0xAE6A = 44650 → = 3.406577 V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #57 voltage UX_HVBAT_C57_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 896 to 911 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #58 voltage UX_HVBAT_C58_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 912 to 927 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #59 voltage UX_HVBAT_C59_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 928 to 943 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #60 voltage UX_HVBAT_C60_VConfirmed
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 944 to 959 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #61 voltage UX_HVBAT_C61_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 960 to 975 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #62 voltage UX_HVBAT_C62_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 976 to 991 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #63 voltage UX_HVBAT_C63_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #64 voltage UX_HVBAT_C64_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #65 voltage UX_HVBAT_C65_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #66 voltage UX_HVBAT_C66_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #67 voltage UX_HVBAT_C67_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #68 voltage UX_HVBAT_C68_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #69 voltage UX_HVBAT_C69_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #70 voltage UX_HVBAT_C70_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #71 voltage UX_HVBAT_C71_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #72 voltage UX_HVBAT_C72_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #73 voltage UX_HVBAT_C73_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #74 voltage UX_HVBAT_C74_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #75 voltage UX_HVBAT_C75_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #76 voltage UX_HVBAT_C76_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #77 voltage UX_HVBAT_C77_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #78 voltage UX_HVBAT_C78_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #79 voltage UX_HVBAT_C79_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #80 voltage UX_HVBAT_C80_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #81 voltage UX_HVBAT_C81_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #82 voltage UX_HVBAT_C82_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #83 voltage UX_HVBAT_C83_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #84 voltage UX_HVBAT_C84_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #85 voltage UX_HVBAT_C85_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #86 voltage UX_HVBAT_C86_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #87 voltage UX_HVBAT_C87_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #88 voltage UX_HVBAT_C88_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #89 voltage UX_HVBAT_C89_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #90 voltage UX_HVBAT_C90_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #91 voltage UX_HVBAT_C91_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #92 voltage UX_HVBAT_C92_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #93 voltage UX_HVBAT_C93_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #94 voltage UX_HVBAT_C94_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,488 to 1,503 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #95 voltage UX_HVBAT_C95_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,504 to 1,519 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
HV battery cell #96 voltage UX_HVBAT_C96_V
- Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2019 to 2024, 2026
Bits 1,520 to 1,535 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Brakes
Master cylinder sensor temperature UX_MASTER_CYL_TEMPConfirmed
- Service 22
DID 1006 - Module
7B0 → 7B8 - Every
5 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -20 to 100 °C
- Unit
- °C
0x49 = 73 → = -7 °C
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Parking brake actuator status UX_EPB
- Service 22
DID 1045 - Module
7B0 → 7B8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | APPLIED | Applied |
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Climate
Adjusted ambient temperature UX_ADJUSTED_AMBIENT_TConfirmed
- Service 21
PID 3D - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -30.8 to 50.8 °C
- Unit
- °C
0x44 = 68 → = -9.04 °C
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Air inlet damper actual pulse UX_AIR_INLET_DAMPER_ACTUAL_PULSEConfirmed
- Service 21
PID 44 - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x5C = 92 → 92
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Air inlet damper target pulse UX_AIR_INLET_DAMPER_TARGET_PULSEConfirmed
- Service 21
PID 44 - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x5C = 92 → 92
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Air mix servo, actual pulse, driver UX_AIR_MIX_SERVO_ACT_DConfirmed
- Service 21
PID 41 - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x25 = 37 → 37
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Air outlet servo pulse, driver UX_AIR_OUTLET_SERVO_PULSE_DConfirmed
- Service 21
PID 43 - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x80 = 128 → 128
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Air outlet servo, actual pulse, driver UX_AIR_OUTLET_SERVO_ACTU_PULSE_DConfirmed
- Service 21
PID 43 - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x80 = 128 → 128
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Ambient temperature UX_AMBIENT_T_700Confirmed
- Service 22
DID 1F46 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x1B = 27 → = -13 °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Ambient temperature, climate UX_AAT_7C4_V2
- Service 22
DID 1002 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Blower level UX_BLOWER
- Service 22
DID 2801 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Blower motor speed level UX_BLOWER_MOTOR_SPEED_LEVELConfirmed
- Service 21
PID 3C - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Cabin temperature UX_CABIN_T_V2
- Service 22
DID 1001 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Climate set point code UX_HVAC_SET_RAW
- Service 22
DID 1036 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Communication with air conditioner UX_COMM_WITH_AIR_CONDITIONER
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Communication with HV UX_COMMUNICATION_WITH_HV
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Communication with valvematic UX_COMM_WITH_VALVEMATIC_COMM
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Evaporator fin thermistor UX_EVAP_FIN_THERMISTORConfirmed
- Service 21
PID 4B - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -29.7 to 59.55 °C
- Unit
- °C
0x44 = 68 → = -5.9 °C
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Set temperature, driver side UX_T_DRIVER
- Service 21
PID 29 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Solar sensor, driver side UX_SOLAR_DRIVER
- Service 21
PID 24 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Control
A/C compressor UX_A_C_COMPRESSOR
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 64 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Accelerator pedal UX_ACCEL_PEDAL
- Service 22
DID 1059 - Module
700 → 708 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Accelerator pedal, position 1 UX_ACC_PEDAL_POS_1Confirmed
- Service 22
DID 1F49 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x28 = 40 → = 15.686275 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Accelerator pedal, position 2 UX_ACC_PEDAL_POS_2Confirmed
- Service 22
DID 1F4A - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x51 = 81 → = 31.764706 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Accelerator sensor 1 voltage UX_ACCEL_SENS__NO_1_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Accelerator sensor 2 voltage UX_ACCEL_SENS__NO_2_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Anti-lock brake warning UX_ABS_WARNINGConfirmed
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Brake pedal stroke UX_BRAKE_STROKE
- Service 22
DID 104C - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mm
- Unit
- mm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Brake warning UX_BRAKE_WARNINGConfirmed
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Buzzer UX_BUZZERConfirmed
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Check engine UX_CHECK_ENGINE
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Communication with brake UX_COMMUNICATION_WITH_BRAKE
- Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Cruise control live brake cancel UX_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCH
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Electrical load signal 1 UX_ELECTRICAL_LOAD_SIGNAL_1
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Electrical load signal 2 UX_ELECTRICAL_LOAD_SIGNAL_2
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Electronically controlled brake warning UX_ECB_WARNINGConfirmed
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Ignition trigger count UX_IGNITION_TRIG_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Key remind sound UX_KEY_REMIND_SOUND
- Service 21
PID A1 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Neutral position UX_NEUTRAL_POSITION_SW_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 53 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Parking brake UX_PARKING_BRAKE_7B0Confirmed
- Service 21
PID 1F - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Power mode pattern switch UX_PATTERN_SWITCH_PWR
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 42 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Power steering UX_POWER_STEERING_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Shift SW status, d range UX_SHIFT_SW_STATUS_D_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Shift SW status, n range UX_SHIFT_SW_STATUS_N_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Shift SW status, p range UX_SHIFT_SW_STATUS_P_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Shift SW status, r range UX_SHIFT_SW_STATUS_R_RANGE
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Slip indicator UX_SLIP_INDICATORConfirmed
- Service 21
PID 3D - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Sports mode selection UX_SPORTS_MODE_SELECTION_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 32 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Sports shift down UX_SPORTS_SHIFT_DOWN_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 34 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Sports shift up UX_SPORTS_SHIFT_UP_SW
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 33 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Starter control UX_STARTER_CONTROL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Starter signal UX_STARTER_SIGNAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Steering angle UX_STEERING_ANGLEConfirmed
- Service 22
DID 1004 - Module
7B3 → 7BB - Every
250 ms - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -410 to 410 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Steering wheel angle UX_STEER_ANGLEConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -3276 to 3276.7 °
- Unit
- °
0x939D = 37789 → = 502.1 °
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Tail cancel UX_TAIL_CANCEL
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
TC UX_TC_TERMINAL
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 61 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Traction brake control UX_TRC_BRAKE_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Traction control UX_TRC_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Traction engine control UX_TRC_ENGINE_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Zero point of deceleration UX_ZP_DECConfirmed
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.56 to 2.54 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Zero point of deceleration 2 UX_ZP_DEC2Confirmed
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.56 to 2.54 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Zero point of yaw rate UX_ZP_YAW_RATEConfirmed
- Service 21
PID 46 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 °
- Unit
- °
0x80 = 128 → = 0 °
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Cruise control
Cruise control speed UX_CC_S
- Service 21
PID 21 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Details
Inspection mode UX_INSPECTION_MODEConfirmed
- Service 21
PID A6 - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Drivetrain
Drive mode UX_DRIVE_MODE
- Service 22
DID 1004 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NORMAL | Normal |
1 | POWER | Power |
2 | SPORT | Sport |
3 | SPORT_S | Sport S |
4 | SPORT_S_PLUS | Sport S+ |
5 | COMFORT | Comfort |
6 | ECO | Eco |
9 | RANGE | Range |
11 | CHAUFFEUR | Chauffeur |
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Ready to drive UX_READYConfirmed
- Service 22
DID 1076 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b1 = 1 → 1
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
DTCs
2nd air monitor avail UX_2ND_AIR_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
2nd air monitor incomplete UX_2ND_AIR_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
A/C monitor avail UX_A_C_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
A/C monitor incomplete UX_A_C_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Air-fuel sensor heater monitor available UX_O2S_A_FS__HEATER_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Air-fuel sensor heater monitor incomplete UX_O2S_A_FS__HEATER_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Air-fuel sensor monitor available UX_O2S_A_FS__MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Air-fuel sensor monitor incomplete UX_O2S_A_FS__MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Catalyst monitor avail UX_CATALYST_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Catalyst monitor incomplete UX_CATALYST_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Complete parts monitor_avail UX_COMPLETE_PARTS_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2025. Supported for 2020, 2023.
EGR/VVT monitor avail UX_EGR_VVT_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
EGR/VVT monitor incomplete UX_EGR_VVT_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
EVAP monitor avail UX_EVAP_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
EVAP monitor_icmpl UX_EVAP_MONITOR_ICMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Fuel system monitor_avail UX_FUEL_SYSTEM_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Heated catalyst monitor avail UX_HEATED_CATALYST_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Heated catalyst monitor incomplete UX_HEATED_CATALYST_MONITOR_INCMPL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
MIL UX_MIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
MIL ON run distance UX_MILON_RUN_DISTANCE
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Misfire monitor avail UX_MISFIRE_MONITOR_AVAIL
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Number of emission DTC UX_NUMBER_OF_EMISSION_DTC
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Running time from MIL ON UX_RUNNING_TIME_FROM_MIL_ON
- Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Electrical
12V battery charge, total UX_12V_AH_INConfirmed
- Service 22
DID 15E8 - Module
7D2 → 7DA - Every
60 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
0x00004798 = 18328 → = 1,832.8 Ah
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
12V battery discharge, total UX_12V_AH_OUTConfirmed
- Service 22
DID 15E8 - Module
7D2 → 7DA - Every
60 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
0x000003E8 = 1000 → = 100 Ah
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
12V battery full charge capacity UX_12V_CAPConfirmed
- Service 22
DID 15E5 - Module
7D2 → 7DA - Every
60 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 Ah
- Unit
- Ah
0x6D = 109 → = 54.5 Ah
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Battery voltage UX_BATTERY_VOLTAGEConfirmed
- Service 22
DID 1021 - Module
7C0 → 7C8 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20 V
- Unit
- V
0x00 = 0 → = 0 V
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Engine
A/F heater duty bank 1 sensor 1 UX_F_HEATER_DUTY_B1S1
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
A/F ratio learn value high, bank 1 UX_AF_LEARN_HIGH_PORT_B1Confirmed
- Service 22
DID 10A2 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
0x88 = 136 → = 3.333333 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
A/F ratio learn value idle, bank 1 UX_AF_LEARN_IDLE_PORT_B1Confirmed
- Service 22
DID 10A2 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
0x69 = 105 → = -8.823529 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
A/F ratio learn value low, bank 1 UX_AF_LEARN_LOW_PORT_B1Confirmed
- Service 22
DID 10A2 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
A/F ratio learn value mid.1, bank 1 UX_AF_LEARN_MID1_PORT_B1Confirmed
- Service 22
DID 10A2 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
0x97 = 151 → = 9.215686 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
A/F ratio learn value mid.2, bank 1 UX_AF_LEARN_MID2_PORT_B1Confirmed
- Service 22
DID 10A2 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
0x88 = 136 → = 3.333333 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
A/F ratio learned high, bank 1 UX_A_F_RATIO_LEARNED_HIGH_BANK_1Confirmed
- Service 22
DID 102A - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
0x88 = 136 → = 3.333333 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
A/F ratio learned idle, bank 1 UX_A_F_RATIO_LEARNED_IDLE_BANK_1Confirmed
- Service 22
DID 102A - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
0x7C = 124 → = -1.372549 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
A/F ratio learned low, bank 1 UX_A_F_RATIO_LEARNED_LOW_BANK_1Confirmed
- Service 22
DID 102A - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
0x7C = 124 → = -1.372549 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
A/F ratio learned mid 1, bank 1 UX_A_F_RATIO_LEARNED_MID_1_BANK_1Confirmed
- Service 22
DID 102A - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
A/F ratio learned mid 2, bank 1 UX_A_F_RATIO_LEARNED_MID_2_BANK_1Confirmed
- Service 22
DID 102A - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -50 to 50 %
- Unit
- %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
A/F test results 1, incomplete UX_F_TEST_RESULTS_1
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Accelerator pedal position UX_APP_V2Confirmed
- Service 22
DID 1060 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Accessory relay on UX_ACC_RELAY_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 46 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Accumulator open UX_ACCUMULATOR_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Acoustic control induction system vacuum switching valve on UX_ACIS_VSV_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Actual engine torque UX_ACT_ENG_TQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Actuator power supply on UX_ACTUATOR_POWER_SUP_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 146 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
AF lambda B1S1 UX_AF_LAMBDA_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Air conditioning compressor UX_AC_COMP
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Air conditioning power consumption UX_AC_POWER_CONSConfirmed
- Service 22
DID 106E - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12.75 kW
- Unit
- kW
0x00 = 0 → = 0 kW
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Air conditioning power consumption UX_AC_POWER_CONS_747
- Service 22
DID 106E - Module
747 → 74F - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -12500 to -12500 kW
- Unit
- kW
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Air mix servo target pulse, driver UX_AIR_MIX_SERVO_TARG_DConfirmed
- Service 21
PID 41 - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x25 = 37 → 37
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Air-fuel sensor current, bank 1 sensor 1 UX_AFS_CURRENT_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 127.99 mA
- Unit
- mA
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Air-fuel sensor voltage, bank 1 sensor 1 UX_AFS_VOLTAGE_B1S1
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.99 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Alt voltage - active test UX_ALT_VOL_ACTIVE_TEST
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Alt voltage - non active test UX_ALT_VOL_NON_ACTIVE
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Alternator output duty UX_ALTERNATOR_OUTPUT
- Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Alternator output duty cycle UX_ALT_DUTY_CYCLE
- Service 22
DID 15FA - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Ambient air temperature UX_AAT_7C4Confirmed
- Service 21
PID 22 - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -23.3 to 65.95 °C
- Unit
- °C
0x2A = 42 → = -8.6 °C
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Ambient temperature UX_AATConfirmed
- Service 22
DID 1F46 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Ambient temperature UX_AMBIENT_T
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Atmosphere pressure UX_ATMOSPHERE_PRESSURE
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Cabin temperature UX_CABIN_TConfirmed
- Service 21
PID 21 - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -6.5 to 57.25 °C
- Unit
- °C
0x20 = 32 → = 1.5 °C
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. Supported for 2020, 2023.
Calculated load_7e0 UX_CALCULATED_LOAD_7E0
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Catalyst temperature B1S1 UX_CATALYST_T_B1S1
- Service 21
PID 05 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Catalyst temperature B1S2 UX_CATALYST_T_B1S2
- Service 21
PID 05 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Catalyst temperature bank 1 sensor 2 UX_CAT_T_B1S2
- Service 21
PID 3E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Catalyst temperature bank 2 sensor 1 UX_CAT_T_BANK_2_SENS_1
- Service 22
DID 1F3D - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Catalyst temperature bank 2 sensor 2 UX_CAT_T_BANK_2_SENS_2
- Service 22
DID 1F3F - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Check mode on UX_CHECK_MODE_ON
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Closed throttle position switch on UX_CLOSED_THROTTLE_POS_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 125 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Codes, include history UX_CODES_INCLUDE
- Service 21
PID E1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2025. Supported for 2020, 2023.
Continuously variable transmission learning complete UX_CVT_LEARNED
- Service 21
PID DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Continuously variable transmission oil pressure UX_CVT_OIL_P
- Service 21
PID BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 10200 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Coolant temp UX_COOLANT_TEMP
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Coolant temperature UX_COOL_TConfirmed
- Service 22
DID 1F05 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x36 = 54 → = 14 °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Coolant temperature UX_COOLANT_T
Pelican can show this parameter as the engine coolant temperature.
- Service 21
PID 23 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Coolant water route switching valve 1, closed? UX_COOLANT_VALVE_1_CLOSE
- Service 22
DID 282C - Module
700 → 708 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Coolant water route switching valve 2, closed? UX_COOLANT_VALVE_2_CLOSE
- Service 22
DID 2847 - Module
700 → 708 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Cooling fan duty ratio UX_COOLING_FAN_DUTY_RATIOConfirmed
- Service 22
DID 1046 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Cruise control on UX_CRUISE_CTRL_ON
- Service 21
PID D3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Cylinder 1 injection volume UX_CYL_1_INJ_VOLUME
- Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -640 to 15
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Cylinder 2 injection volume UX_CYL_2_INJ_VOLUME
- Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -640 to 15
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Cylinder 3 injection volume UX_CYL_3_INJ_VOLUME
- Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -640 to 15
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Cylinder 4 injection volume UX_CYL_4_INJ_VOLUME
- Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -640 to 15
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Cylinder number UX_CYLINDER_NUMBER
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Destination UX_DESTINATION
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Diesel particulate filter differential pressure UX_DPF_DIFF_PConfirmed
- Service 22
DID 1F7A - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 23 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 kPa
- Unit
- kPa
0x0001 = 1 → = 0.01 kPa
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Dist battery cable disconnect UX_DIST_BATT_CABLE
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Electric fan motor on UX_ELEC_FAN_MOTOR_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 34 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Electric thermostat duty ratio UX_ELECTRIC_THERMOSTAT_DUTY_RATIO
- Service 22
DID 2829 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Electric water pump UX_ELECTRIC_WATER_PUMPConfirmed
- Service 22
DID 2827 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 10200 rpm
- Unit
- rpm
0x04 = 4 → = 160 rpm
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Electric water pump RPM UX_EWP_RPMConfirmed
- Service 22
DID 1043 - Module
700 → 708 - Every
250 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
0x06 = 6 → = 150 rpm
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Electric water pump target speed UX_EWP_TARGET_VSSConfirmed
- Service 22
DID 1043 - Module
700 → 708 - Every
250 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
0x00 = 0 → = 0 rpm
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Engine coolant temperature UX_ECTConfirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 21
PID 26 - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 1.3 to 90.55 °C
- Unit
- °C
0x2A = 42 → = 16 °C
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Engine coolant temperature, at ignition UX_ECT_IGNConfirmed
- Service 22
DID 1041 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119.375 °C
- Unit
- °C
0x3A = 58 → = -3.75 °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Engine coolant temperature, initial UX_ECT_INITConfirmed
- Service 22
DID 1041 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 119.375 °C
- Unit
- °C
0x3B = 59 → = -3.125 °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Engine independent UX_ENG_INDEPENDENT
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 91 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Engine independent control UX_ENG_INDEPENDENT_CTRL
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 88 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Engine oil pressure UX_EOPConfirmed
- Service 22
DID 1074 - Module
700 → 708 - Every
250 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 kPa
- Unit
- kPa
0x0000 = 0 → = 0 kPa
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Engine oil pressure control valve UX_EOP_CONTROL_VALVEConfirmed
- Service 22
DID 2848 - Module
700 → 708 - Every
500 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4999.9207 mA
- Unit
- mA
0x0000 = 0 → = 0 mA
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Engine oil temperature UX_EOT
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 107B - Module
700 → 708 - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Engine oil temperature UX_EOT_V1
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Engine oil temperature UX_EOT_V2Confirmed
- Service 22
DID 1F5C - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x2B = 43 → = 3 °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Engine run time UX_ENGINE_RUN_TIME
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Engine run time, up to 255 sec. only UX_ENG_RUN_TIME_UP_255
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 s
- Unit
- s
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Engine stall control FB flow UX_ENG_STALL_CTRL_FB
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 39.99
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
EVAP purge duty UX_EVAP_PURGE_DUTY
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Evaporative purge duty UX_EVAP_PURGE_DUTY_7E0
- Service 21
PID 2E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Evaporative purge flow UX_EVAP_PURGE_FLOW
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.99 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Evaporative purge vacuum switching valve on UX_EVAP_PURGE_VSV_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Evaporator target temp UX_EVAP_TARG_TConfirmed
- Service 21
PID 4C - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Number
0x8064 = 32868 → = 1
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Exhaust gas recirculation step position UX_EGR_STEP_POSITION
- Service 21
PID 47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Exhaust gas recirculation temperature UX_EGR_T
- Service 21
PID ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 159 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Exhaust gas recirculation valve step UX_EGR_STEP
- Service 21
PID E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Exhaust VVT change angle, bank 1 UX_EXHAUST_VVT_ANGLE_B1Confirmed
- Service 22
DID 1088 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Exhaust VVT hold learn value, bank 1 UX_EXHAUST_VVT_HOLD_LEARN_B1Confirmed
- Service 22
DID 1089 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
0x1E70 = 7792 → = 47.54743 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Exhaust VVT oil control valve control duty UX_EXHAUST_VVT_OCV_CONTROL_DUTYConfirmed
- Service 22
DID 1062 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 400 %
- Unit
- %
0x0000 = 0 → = 0 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Exhaust VVT target angle B1 UX_EXHAUST_VVT_TARGET_ANGLE_B1Confirmed
- Service 22
DID 1071 - Module
700 → 708 - Every
250 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Exhaust VVT timing most over-advanced learn value, bank 1 UX_EXHAUST_VVT_OVER_ADV_LEARN_B1Confirmed
- Service 22
DID 108F - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.99 °
- Unit
- °
0x2478 = 9336 → = 91.171842 °
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Front/rear motor torque ratio UX_FRONT_REAR_MOTOR_TQConfirmed
- Service 22
DID 1039 - Module
7D2 → 7DA - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -32.76 to 32.76
- Unit
- Number
0x0C6C = 3180 → = -29.588
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Fuel cut for engine stop request UX_F_C_ENG_STOP_REQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 92 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel cut TAU on UX_FC_TAU_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 127 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel filter temperature UX_FFT
- Service 22
DID 109A - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
G sensor calibration, complete UX_G_SENS_CALIBRATION
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
G sensor learning value UX_G_SENS_LEARNING
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Generator inverter temperature UX_GEN_INVERTER_TConfirmed
- Service 22
DID 10A4 - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x35 = 53 → = 13 °C
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Generator inverter temperature UX_GEN_INVERTER_T_7D2
- Service 22
DID 10A8 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Generator inverter temperature after ignition on UX_GEN_INVERTER_T_AFTER_ON
- Service 22
DID 10A8 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Glass humidity UX_GLASS_HUMIDITY
- Service 21
PID B1 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Glass temperature UX_GLASS_T
- Service 21
PID AF - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -557 to 621 °F
- Unit
- °F
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV communication open UX_HV_COMMUNICATION_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
ICE, actual torque UX_ICE_ACT_TQ
- Service 21
PID CD - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 N·m
- Unit
- N·m
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Idle control UX_IDLE_CTRL
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Idle spark advance control 1 UX_IDLE_SPARK_ADVN_CTRL_1
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Idle spark advance control 2 UX_IDLE_SPARK_ADVN_CTRL_2
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Idle spark advance control 3 UX_IDLE_SPARK_ADVN_CTRL_3
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Idle spark advance control 4 UX_IDLE_SPARK_ADVN_CTRL_4
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.93 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Idle spark advance control, cylinder 1 UX_IDLE_SAC_CYL_1Confirmed
- Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.9375 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Idle spark advance control, cylinder 2 UX_IDLE_SAC_CYL_2Confirmed
- Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.9375 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Idle spark advance control, cylinder 3 UX_IDLE_SAC_CYL_3Confirmed
- Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.9375 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Idle spark advance control, cylinder 4 UX_IDLE_SAC_CYL_4Confirmed
- Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 15.9375 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Idle speed control learning UX_IDLE_SPD_CTRL
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 93 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Idle speed control learning value, l/s UX_IDLE_SPD_CTRL_L_S
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
- Range
- 0 to 79.99
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
IG OFF elapsed time UX_IG_OFF_ELAPSED_TIME
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 min
- Unit
- min
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Ignition advance UX_IGN_ADVANCE
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Ignition advance UX_SPARKADV_21
- Service 21
PID 0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Immobilizer communication on UX_IMMOBILIZER_ON
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 120 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Initial engine coolant temperature UX_INITIAL_ECT
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 119.3
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Initial intake air temperature UX_INITIAL_IAT
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection UX_INJECTIONConfirmed
- Service 22
DID 1019 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
0x01 = 1 → DIRECT
| Raw value | State | Meaning |
|---|---|---|
1 | DIRECT | Direct |
2 | BOTH | Both |
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Injection duration for cylinder 1 UX_INJ_DUR_CYL_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection feedback value 1 UX_INJ_FEEDBACK_1
- Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -20 to 15
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection feedback value 1 UX_INJ_FEEDBACK_1_700
- Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection feedback value 2 UX_INJ_FEEDBACK_2
- Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -20 to 15
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection feedback value 2 UX_INJ_FEEDBACK_2_700
- Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection feedback value 3 UX_INJ_FEEDBACK_3
- Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -20 to 15
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection feedback value 3 UX_INJ_FEEDBACK_3_700
- Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection feedback value 4 UX_INJ_FEEDBACK_4
- Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -20 to 15
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection feedback value 4 UX_INJ_FEEDBACK_4_700
- Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection feedback value 5 UX_INJ_FEEDBACK_5
- Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection feedback value 6 UX_INJ_FEEDBACK_6
- Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection volume UX_INJ_VOLConfirmed
- Service 22
DID 1017 - Module
700 → 708 - Every
250 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 20 L
- Unit
- L
0x0000 = 0 → = 0 L
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Injection volume - target UX_INJ_VOLUME_TGT
- Service 22
DID 112C - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection volume 1 UX_INJ_VOLUME_1
- Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 300
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection volume 2 UX_INJ_VOLUME_2
- Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 300
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection volume 3 UX_INJ_VOLUME_3
- Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 300
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection volume 5 UX_INJ_VOLUME_5
- Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 300
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection volume 6 UX_INJ_VOLUME_6
- Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- -40 to 300
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection volume per 10 injections, cylinder 1 UX_INJ_VOL_CYL_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.002 L
- Unit
- L
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injection volume total UX_INJ_VOLUME_TOT
- Service 22
DID 112F - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -640 to 15
- Unit
- Raw value
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injector port UX_INJECTOR_PORTConfirmed
- Service 22
DID 1018 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Injector pulse width UX_INJ_PW
- Service 21
PID E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.6 ms
- Unit
- ms
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Injector pulse width UX_INJ_WIDTH
- Service 21
PID F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.64 ms
- Unit
- ms
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Input shaft speed UX_SPD_NIN
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Intake air UX_INTAKE_AIR
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Intake air temperature UX_IAT_21
- Service 21
PID 0F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Intake air temperature, bank 1 sensor 1 UX_IAT_B1S1
- Service 22
DID 1F77 - Module
700 → 708 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Intake air temperature, bank 1 sensor 2 UX_IAT_B1S2
- Service 22
DID 1F77 - Module
700 → 708 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Intake VVT change angle, bank 1 UX_INTAKE_VVT_CHANGE_ANGLE_BANK_1Confirmed
- Service 22
DID 1087 - Module
700 → 708 - Every
250 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Intake VVT most over-retarded learn value, bank 1 UX_INTAKE_VVT_OVER_RET_LEARN_B1Confirmed
- Service 22
DID 108D - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.99 °
- Unit
- °
0x0E39 = 3641 → = 35.556628 °
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Intake VVT target angle B1 UX_INTAKE_VVT_TARGET_ANGLE_B1Confirmed
- Service 22
DID 106F - Module
700 → 708 - Every
250 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
0x0000 = 0 → = 0 °
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Integrated engine run time UX_INTEGRATED_ENG_RUN
- Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 h
- Unit
- h
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Intercooler coolant temperature UX_INTERCOOLER_ECT
- Service 22
DID 119C - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Intercooler water pump UX_INTERCOOLER_WATER
- Service 22
DID 2820 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Internal temperature UX_ECU_INTERNAL_TConfirmed
- Service 22
DID 105E - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x27 = 39 → = -1 °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Inverter coolant temperature UX_INVRT_COOLANT_TConfirmed
- Service 22
DID 10B2 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 °C
- Unit
- °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Inverter water pump duty UX_INVERTER_WATER_PMP
- Service 22
DID 1112 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 199 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Judge time engine ignition UX_JUDGE_TIME_ENG_IGN
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Judge time engine output UX_JUDGE_TIME_ENG
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Key cycle UX_KEY_CYCLEConfirmed
- Service 22
DID 0102 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x12FF = 4863 → 4,863
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Knock adjust UX_KNOCK_ADJUST
- Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -64 to 1984 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Knock adjust UX_KNOCK_ADJUST_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1024 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Knock correct learn value UX_KNOCK_CORRECT_LEARN
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1023 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Knock correction, learned value UX_KNOCK_CORRECT_LEARNED_VALUEConfirmed
- Service 22
DID 105C - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1023
- Unit
- Number
0x81A9 = 33193 → = 13.28125
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Knock feedback UX_KNOCK_FEEDBACK
- Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -64 to 1984 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Knock feedback UX_KNOCK_FEEDBACK_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1024 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Knock feedback value UX_KNOCK_FEEDBACK_VALUEConfirmed
- Service 22
DID 105C - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -1024 to 1023
- Unit
- Number
0x7FA0 = 32672 → = -3
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Long FT B1S1 UX_LONG_FT_B1S1
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.218 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Long-term fuel trim, bank 1 UX_LTFT1_21
- Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.15 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Main idle UX_MAIN_IDLEConfirmed
- Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Manifold absolute pressure UX_MAP
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Mass air flow UX_MAF
Pelican can show this parameter as the mass air flow.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Mass air flow UX_MAF_21
- Service 21
PID 10 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 g/s
- Unit
- g/s
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Master cylinder open UX_MASTER_CYLINDER_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Maximum generator inverter temperature UX_MAX_GEN_INVERTER_T
- Service 22
DID 10A8 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Maximum motor inverter temperature UX_MAX_MOTOR_INVERTER_TConfirmed
- Service 22
DID 10A5 - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x4E = 78 → = 38 °C
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Misfire load UX_MISFIRE_LOAD_700Confirmed
- Service 22
DID 10AA - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Misfire margin UX_MISFIRE_MARGIN_700
- Service 22
DID 10AA - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024, 2026. Supported for 2023, 2025.
Misfire RPM UX_MISFIRE_RPM_700
- Service 22
DID 10AA - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024, 2026. Supported for 2023, 2025.
Misfire test result, incomplete UX_MIS_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Model year UX_MODEL_YEAR
- Service 21
PID C1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 1900 to 2155
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Motor inverter temperature UX_MOTOR_INVERTER_TConfirmed
- Service 22
DID 10A5 - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x34 = 52 → = 12 °C
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Motor inverter temperature after ignition on UX_MOTOR_INVERTER_T_ONConfirmed
- Service 22
DID 10A5 - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x40 = 64 → = 24 °C
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Motor inverter, maximum temperature UX_M_INVRT_MAX_TConfirmed
- Service 22
DID 10A6 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x3B = 59 → = 19 °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Motor regenerative brake torque UX_MOTOR_REGENERATIVE_BREAKConfirmed
- Service 22
DID 1069 - Module
7D2 → 7DA - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 kW
- Unit
- kW
0x78ED = 30957 → = -226.375 kW
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Motor regenerative brake torque, requested UX_MOTOR_REGENERATIVEConfirmed
- Service 22
DID 1069 - Module
7D2 → 7DA - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 kW
- Unit
- kW
0x78ED = 30957 → = -226.375 kW
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Motor RPM UX_RPMConfirmed
- Service 22
DID 10A1 - Module
7D2 → 7DA - Every
250 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
0x7D6D = 32109 → = -659 rpm
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Motor torque UX_TQConfirmed
- Service 22
DID 10A1 - Module
7D2 → 7DA - Every
250 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 N·m
- Unit
- N·m
0x7FC5 = 32709 → = -7.375 N·m
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
O2 heater b1s2_active UX_O2_HEATER_B1S2
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 68 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
O2 heater current val bank 1 sensor 2 UX_O2_HEATER_CURR_VAL
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.999 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
O2S, bank 1 sensor 2 UX_O2S_B1S2
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Open side malfunction on UX_OPEN_SIDE_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 145 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Output shaft speed UX_SPD_NOUT
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
OXS1, A/FS2 test result, incomplete UX_OXS1_FS2_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Oxygen sensor voltage, bank 1 sensor 1 UX_O2S11_V
- Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.27 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
PM accumulation ratio - bank 1 UX_PM_ACCUMULATION_RAT_1
- Service 22
DID 1105 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 15 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Purge cut vacuum switching valve duty UX_PURGE_CUT_VSV_DUTY
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Racing operation UX_RACING_OPERATION
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 90 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Rear motor inverter, coolant temperature UX_RM_INVRT_COOL_TConfirmed
- Service 22
DID 10A6 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x28 = 40 → = 0 °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Rear motor regenerative brake torque UX_REAR_MOTOR_REGENERATIVE
- Service 22
DID 106A - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 kW
- Unit
- kW
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Rear motor regenerative brake torque, requested UX_REAR_MOTOR
- Service 22
DID 106A - Module
7D2 → 7DA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 kW
- Unit
- kW
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Rear motor speed UX_RM_TQ_REQConfirmed
- Service 22
DID 10A2 - Module
7D2 → 7DA - Every
250 ms - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
0x7DF1 = 32241 → = -527 rpm
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Rear motor torque UX_RM_TQConfirmed
- Service 22
DID 10A2 - Module
7D2 → 7DA - Every
250 ms - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095 N·m
- Unit
- N·m
0x7FFF = 32767 → = -0.125 N·m
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Regulator pressure UX_REGULATOR_PConfirmed
- Service 21
PID 53 - Module
7C4 → 7CC - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -456.68 to 3294 kPa
- Unit
- kPa
0x29 = 41 → = 146.43 kPa
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Request engine run time UX_REQ_ENG_RUN_TIME
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 s
- Unit
- s
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Request warm-up UX_REQ_WARM_UP
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 89 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Requested engine torque UX_REQ_ENG_TQ
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Rough idle, cylinder 1 UX_ROUGH_IDLE_CYL_1
- Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Rough idle, cylinder 2 UX_ROUGH_IDLE_CYL_2
- Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Rough idle, cylinder 3 UX_ROUGH_IDLE_CYL_3
- Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Rough idle, cylinder 4 UX_ROUGH_IDLE_CYL_4
- Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Short FT B1S1 UX_SHORT_FT_B1S1
- Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.218 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2025. Supported for 2020, 2023.
Starter relay on UX_STARTER_RELAY_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 47 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Stroke open UX_STROKE_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
System guard on UX_SYSTEM_GUARD_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 144 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle fully close learn UX_THROTTLE_FULLY_CLOSE
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle idle position on UX_THROTTLE_IDLE_POS_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 149 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle motor current UX_THROTTLE_MOTOR
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 19.9 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle motor duty UX_THROTTLE_MOTOR_DUTY
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Throttle motor duty, close UX_THROTTLE_MOTOR_DUTY_CLOSE
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle motor duty, open UX_THROTTLE_MOTOR_DUTY_OPEN
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle position UX_THROTTLE_21
- Service 21
PID 11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle position command UX_THROTTLE_POS_COMMAND
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle position, number 1 UX_THROTTLE_POS_NUMBER_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle position, number 2 UX_THROTTLE_POS_NUMBER_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle require position UX_THROTTLE_REQUIRE_POS
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle sensor 2 voltage UX_THROTTL_SENSOR__2_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Throttle sensor open position 1 UX_THROTTLE_SENS_OPEN_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle sensor open position 2 UX_THROTTLE_SENS_OPEN_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Throttle sensor position UX_THROTTLE_SENSOR_POSITION
Pelican can show this parameter as the throttle position.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Throttle sensor voltage UX_THROTTLE_SENSOR_VOLT
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Time after DTC cleared UX_TIME_AFTER_DTC_CLEARED
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 min
- Unit
- min
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Total fuel trim, bank 1 UX_TOT_FT_1
- Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -50 to 49.6 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transaxle oil temperature UX_TRANSAXLE_OIL_TConfirmed
- Service 22
DID 1040 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x74 = 116 → = 76 °C
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Transmission fluid temperature UX_ATF_TEMP_700
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1638 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Transmission output shaft speed UX_TRANS_OUT_RPM
- Service 21
PID BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Turbine speed UX_SPD_NT
- Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Valvematic current angle UX_VALVEMATIC_CURRENT
- Service 21
PID 31 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Valvematic, target angle UX_VALVEMATIC_TGT_ANG
- Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 639.9 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Variable valve timing aim angle 1 UX_VARIABLE_VLV_TIM_AIM_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Variable valve timing change angle 1 UX_VARIABLE_VLV_TIM_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 639 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Variable valve timing control status 1 on UX_VARIABLE_VLV_TIM_1_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Variable valve timing duty ratio, bank 1 UX_VVT_IE_DUTY_RATIO_BANK_1Confirmed
- Service 22
DID 108A - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -200 to 199 %
- Unit
- %
0x4000 = 16384 → = -100.023475 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Variable valve timing oil control valve duty 1 UX_VARIABLE_VLV_TIM_OIL_1
- Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 399 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Variable valve timing oil temperature UX_VVTOT
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Variable valve timing opening angle bank 1 UX_VVT_IE_OPENING_ANGLE_BANK_1Confirmed
- Service 22
DID 2843 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
0x00 = 0 → 0 %
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Vehicle load UX_VEHICLE_LOAD
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Vehicle speed UX_VSS_21
- Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Vehicle speed sensor test result, incomplete UX_SPD_TEST_RESULT
- Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Warm-up cycles since DTCs cleared UX_WARMUP_CYCLE_CLEARED_DTC
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Catalyst
Catalyst temperature, bank 1 sensor 1 UX_CAT_T_11Confirmed
- Service 22
DID 1F3C - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x0339 = 825 → = 42.5 °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Catalyst temperature, bank 1 sensor 2 UX_CAT_T_12Confirmed
- Service 22
DID 1F3E - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x028F = 655 → = 25.5 °C
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Misfires
All cylinders misfire count UX_ALL_CYLINDERS_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Cylinder #1 misfire count UX_CYL1_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Cylinder #2 misfire count UX_CYL2_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Cylinder #3 misfire count UX_CYL3_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Cylinder #4 misfire count UX_CYL4_MISFIRE_CNT
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Misfire count, all UX_MIS_ALLConfirmed
- Service 22
DID 10A5 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Misfire count, cylinder 1 UX_MIS_1Confirmed
- Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Misfire count, cylinder 2 UX_MIS_2Confirmed
- Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Misfire count, cylinder 3 UX_MIS_3Confirmed
- Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Misfire count, cylinder 4 UX_MIS_4Confirmed
- Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Misfire load UX_MISFIRE_LOAD
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.98
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Misfire margin UX_MISFIRE_MARGIN
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2025. Supported for 2023.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2025. Supported for 2023.
Fluids
Distance since oil change UX_OIL_CHANGE_ODO
- Service 21
PID 41 - Module
7C0 → 7C8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 41038.272 km
- Unit
- km
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Fuel
Engine fuel rate UX_ENG_FUEL_RATE
- Service 22
DID F19D - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel cut UX_FUEL_CUT
- Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel cut UX_FUEL_CUT_7E0
- Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 121 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel cut time UX_FUEL_CUT_TIME
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 68734.9511
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel injection timing UX_FUEL_INJ_TIM
- Service 21
PID F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 32.64 ms
- Unit
- ms
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel level UX_FLI
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 1F2F - Module
700 → 708 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Fuel level, volume UX_FLI_VOL
Pelican can show this parameter as the fuel tank level.
- Service 21
PID 29 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 L
- Unit
- L
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Fuel pressure 1 UX_FUEL_P_1
- Service 22
DID 113C - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 50000 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel pressure 1 UX_FUEL_P_1_700
- Service 22
DID 11C4 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel pressure 2 UX_FUEL_P_2
- Service 22
DID 113C - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 50000 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel pressure 2 UX_FUEL_P_2_700
- Service 22
DID 11C4 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel pressure 3 UX_FUEL_P_3
- Service 22
DID 113C - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 50000 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel pressure 3 UX_FUEL_P_3_700
- Service 22
DID 11C4 - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel pressure 4 UX_FUEL_P_4
- Service 22
DID 113C - Module
700 → 708 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 50000 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel pressure 4 UX_FUEL_P_4_700
- Service 22
DID 11C4 - Module
700 → 708 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel pressure 5 UX_FUEL_P_5
- Service 22
DID 11C4 - Module
700 → 708 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel pressure 6 UX_FUEL_P_6
- Service 22
DID 11C4 - Module
700 → 708 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel pump duty ratio UX_FUEL_PUMP_DUTY_RATIOConfirmed
- Service 22
DID 106A - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3996 kPa
- Unit
- kPa
0x01EC = 492 → = 30 kPa
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Fuel pump/speed status on UX_FUEL_PMP_SPD_STAT_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel remaining UX_FLVConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 1022 - Module
7C0 → 7C8 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 L
- Unit
- L
0x0127 = 295 → = 2.95 L
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Fuel return temperature UX_FUEL_RETURN_T
- Service 22
DID 1141 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel temperature 1 UX_FUEL_T_1
- Service 22
DID 113E - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel temperature 1 UX_FUEL_T_1_700
- Service 22
DID 11C5 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel temperature 2 UX_FUEL_T_2
- Service 22
DID 113E - Module
700 → 708 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel temperature 2 UX_FUEL_T_2_700
- Service 22
DID 11C5 - Module
700 → 708 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel temperature 3 UX_FUEL_T_3
- Service 22
DID 113E - Module
700 → 708 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel temperature 3 UX_FUEL_T_3_700
- Service 22
DID 11C5 - Module
700 → 708 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel temperature 4 UX_FUEL_T_4
- Service 22
DID 113E - Module
700 → 708 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel temperature 4 UX_FUEL_T_4_700
- Service 22
DID 11C5 - Module
700 → 708 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel temperature 5 UX_FUEL_T_5
- Service 22
DID 11C5 - Module
700 → 708 - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Fuel temperature 6 UX_FUEL_T_6
- Service 22
DID 11C5 - Module
700 → 708 - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
High fuel pressure, actual UX_HFP_ACTUALConfirmed
- Service 22
DID 1F6D - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
0x0172 = 370 → = 3,700 kPa
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
High fuel pressure, target UX_HFP_TARGETConfirmed
- Service 22
DID 1F6D - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
0x0190 = 400 → = 4,000 kPa
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Low fuel pressure UX_LOW_FUEL_PRESSUREConfirmed
- Service 22
DID 1F6D - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
0x0024 = 36 → = 360 kPa
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Low fuel pressure sensor UX_LFPSConfirmed
- Service 22
DID 10CD - Module
700 → 708 - Every
1 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
0x8134 = 33076 → = 30.85 kPa
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Reservoir warning UX_RESERVOIR_WARNINGConfirmed
- Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Target air-fuel ratio UX_TARGET_AIR_FUEL_RATIO
- Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Vehicle fuel rate UX_VEH_FUEL_RATE
- Service 22
DID F19D - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Lights
Hazard switch history UX_HAZARD_SWITCH_HISTORYConfirmed
- Service 21
PID BC - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 2 of the reply.
- Unit
- Named states
0b1 = 1 → COMPLETE
| Raw value | State | Meaning |
|---|---|---|
0 | INCOMPLETE | Incomplete |
1 | COMPLETE | Complete |
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rheostat UX_RHEOSTAT
Higher values are brighter
- Service 21
PID 68 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Stop light UX_STOP_LIGHTConfirmed
- Service 21
PID 1F - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Stop light relay UX_STOP_LIGHT_RELAYConfirmed
- Service 21
PID 3C - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Stop light switch UX_STOP_LIGHT_SWITCH
- Service 21
PID 25 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Movement
Accelerator fully close learn 1 UX_ACCEL_FULLY_CLOSE_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 124.5 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Accelerator fully close learn 2 UX_ACCEL_FULLY_CLOSE_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 124.5 °
- Unit
- °
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Accelerator idle position on UX_ACCEL_IDLE_POS_ON
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 148 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Accelerator position UX_ACCEL_POS
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 399.9 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Accelerator sensor out, number 1 UX_ACCEL_SENS_OUT_1
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Accelerator sensor out, number 2 UX_ACCEL_SENS_OUT_2
- Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 4.98 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Average engine speed of all cylinders UX_AV_RPM_ALL_CYL
Pelican can show this parameter as the engine speed.
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Compressor speed UX_COMP_SPDConfirmed
- Service 21
PID 49 - Module
7C4 → 7CC - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Compressor, target speed UX_COMP_TGT_SPDConfirmed
- Service 21
PID 4A - Module
7C4 → 7CC - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Cruise control speed UX_CRUISE_CTRL_SPD
- Service 21
PID D3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Engine speed UX_ENGINE_SPEED
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Engine speed of cylinder 1 UX_RPM_CYL_1
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Engine speed of cylinder 2 UX_RPM_CYL_2
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Engine speed of cylinder 3 UX_RPM_CYL_3
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Engine speed of cylinder 4 UX_RPM_CYL_4
- Service 21
PID 54 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Front left wheel acceleration UX_FL_ACCConfirmed
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 m/s²
- Unit
- m/s²
0x00 = 0 → 0 m/s²
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Front left wheel speed UX_FL_WHEEL_VSSConfirmed
- Service 22
DID 1075 - Module
7D2 → 7DA - Every
100 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 km/h
- Unit
- km/h
0x8000 = 32768 → = 0 km/h
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Front left wheel speed UX_TIRE_FL_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Front left wheel speed? UX_FL_WHEEL_SPEED_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Front right wheel acceleration UX_FR_ACCConfirmed
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 m/s²
- Unit
- m/s²
0x00 = 0 → 0 m/s²
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Front right wheel speed UX_FR_WHEEL_VSSConfirmed
- Service 22
DID 1075 - Module
7D2 → 7DA - Every
100 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 km/h
- Unit
- km/h
0x8000 = 32768 → = 0 km/h
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Front right wheel speed UX_TIRE_FR_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Front right wheel speed? UX_FR_WHEEL_SPEED_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
High voltage, target engine speed UX_HIGH_V_TGT_RPM
- Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Intercooler water pump speed, raw count UX_IWP_SPEED
- Service 22
DID 1075 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Minimum engine speed UX_MIN_RPM
- Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 51199 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Misfire RPM UX_MISFIRE_RPM
- Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Rear left wheel acceleration UX_RL_ACCConfirmed
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 m/s²
- Unit
- m/s²
0x00 = 0 → 0 m/s²
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear left wheel speed UX_RL_WHEEL_VSSConfirmed
- Service 22
DID 1075 - Module
7D2 → 7DA - Every
100 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 km/h
- Unit
- km/h
0x8000 = 32768 → = 0 km/h
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Rear left wheel speed UX_TIRE_RL_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear left wheel speed? UX_RL_WHEEL_SPEED_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear right wheel acceleration UX_RR_ACCConfirmed
- Service 21
PID 42 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 m/s²
- Unit
- m/s²
0x00 = 0 → 0 m/s²
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear right wheel speed UX_RR_WHEEL_VSSConfirmed
- Service 22
DID 1075 - Module
7D2 → 7DA - Every
100 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -327.68 to 327.67 km/h
- Unit
- km/h
0x8000 = 32768 → = 0 km/h
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Rear right wheel speed UX_TIRE_RR_SPDConfirmed
- Service 21
PID 03 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 326.4 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear right wheel speed? UX_RR_WHEEL_SPEED_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Vehicle speed UX_VEHICLE_SPEED
Pelican can show this parameter as the speed.
- Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Vehicle speed UX_VSS_V1Confirmed
Current vehicle speed.
Pelican can show this parameter as the speed.
- Service 21
PID 21 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 326 km/h
- Unit
- km/h
0x00 = 0 → = 0 km/h
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Vehicle speed UX_VSS_V2Confirmed
Pelican can show this parameter as the speed.
- Service 22
DID 1F0D - Module
7D2 → 7DA - Every
250 ms - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Vehicle speed, 7C0 UX_VSS_7C0
Pelican can show this parameter as the speed.
- Service 21
PID 21 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Orientation
Deceleration open UX_DECELERATION_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Deceleration sensor UX_DECELConfirmed
- Service 21
PID 05 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -18.18 to 18.18 m/s²
- Unit
- m/s²
0x52 = 82 → = -6.487765 m/s²
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Deceleration sensor, alternate UX_DECEL2Confirmed
- Service 21
PID 05 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -18.18 to 18.18 m/s²
- Unit
- m/s²
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Lateral g UX_LAT_GConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.5 to 2.5 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Longitudinal g UX_LNG_GConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -2.5 to 2.5 g
- Unit
- g
0x00 = 0 → = 0 g
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Yaw rate open error? UX_YAW_RATE_ERRORConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Yaw rate sensor UX_YAW_RATE_7B0Confirmed
- Service 21
PID 06 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 °
- Unit
- °
0x56 = 86 → = -42 °
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Yaw rate sensor, alternate UX_YAW_RATE2Confirmed
- Service 21
PID 06 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 °
- Unit
- °
0x56 = 86 → = -42 °
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Yaw rate value (degrees/se UX_YAW_RATEConfirmed
- Service 21
PID 47 - Module
7B0 → 7B8 - Every
250 ms - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -128 to 127 °
- Unit
- °
0x71 = 113 → = -15 °
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Zero point of yaw rate UX_ZERO_POINT_OF_YAW_RATE
- Service 21
PID A1 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Seatbelts
Buckle switch, left side UX_BUCKLE_LS
- Service 21
PID 04 - Module
780 → 788 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Supported for 2023. Not supported for 2025.
Buckle switch, right side UX_BUCKLE_RS
- Service 21
PID 04 - Module
780 → 788 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Supported for 2023. Not supported for 2025.
P-seatbelt buckle UX_P_SEATBELT_BUCKLE
- Service 21
PID 12 - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Reverse beep UX_REVERSE_BEEP
- Service 21
PID AC - Module
7C0 → 7C8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- On or off
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Seat belt beeps UX_SEAT_BELT_BEEP
- Service 21
PID A7 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Stats
Ready-on time, total UX_READY_HOURSConfirmed
- Service 22
DID 15E8 - Module
7D2 → 7DA - Every
60 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 h
- Unit
- h
0x018E = 398 → 398 h
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Tires
Brake assist status UX_BA_CTRL_STATUSConfirmed
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Front left tire pressure UX_TP_FL_V1Confirmed
Pelican can show this parameter as the front left tire pressure.
- Service 21
PID 30 - Module
750 → 758 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.896 bar
- Unit
- bar
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Front left tire pressure UX_TP_FL_V2Confirmed
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 1005 - Module
750 → 758 - Every
5 s - Testing for 2019 to 2024, 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.8 bar
- Unit
- bar
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Front left tire temperature UX_TT_FL
- Service 21
PID 16 - Module
750 → 758 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Front left tire temperature UX_TT_FL_V2Confirmed
- Service 22
DID 1004 - Module
750 → 758 - Every
5 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x00 = 0 → = -40 °C
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Front left wheel ABS status UX_FL_WHEEL_ABS_CTRL_STATUSConfirmed
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Front left wheel stability control UX_FL_WHEEL_VSC_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Front right tire pressure UX_TP_FR_V1Confirmed
Pelican can show this parameter as the front right tire pressure.
- Service 21
PID 30 - Module
750 → 758 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.896 bar
- Unit
- bar
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Front right tire pressure UX_TP_FR_V2Confirmed
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 1005 - Module
750 → 758 - Every
5 s - Testing for 2019 to 2024, 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.8 bar
- Unit
- bar
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Front right tire temperature UX_TT_FR
- Service 21
PID 16 - Module
750 → 758 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Front right tire temperature UX_TT_FR_V2Confirmed
- Service 22
DID 1004 - Module
750 → 758 - Every
5 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x00 = 0 → = -40 °C
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Front right wheel ABS status UX_FR_WHEEL_ABS_CTRL_STATUSConfirmed
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Front right wheel cylinder open UX_FR_WHEEL_CYLINDER_OPENConfirmed
- Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Front right wheel stability control UX_FR_WHEEL_VSC_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Predictive brake assist status UX_PBA_CTRL_STATUSConfirmed
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 12 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear left tire pressure UX_TP_RL_V1Confirmed
Pelican can show this parameter as the rear left tire pressure.
- Service 21
PID 30 - Module
750 → 758 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.896 bar
- Unit
- bar
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear left tire pressure UX_TP_RL_V2Confirmed
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 1005 - Module
750 → 758 - Every
5 s - Testing for 2019 to 2024, 2026
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.8 bar
- Unit
- bar
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Rear left tire temperature UX_TT_RL
- Service 21
PID 16 - Module
750 → 758 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Rear left tire temperature UX_TT_RL_V2Confirmed
- Service 22
DID 1004 - Module
750 → 758 - Every
5 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x00 = 0 → = -40 °C
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Rear left wheel ABS status UX_RL_WHEEL_ABS_CTRL_STATUSConfirmed
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear left wheel EBS status UX_RL_WHEEL_EBD_CTRL_STATUSConfirmed
Electronic brakeforce distribution
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear left wheel stability control UX_RL_WHEEL_VSC_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear right tire pressure UX_TP_RR_V1Confirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 21
PID 30 - Module
750 → 758 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.896 bar
- Unit
- bar
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear right tire pressure UX_TP_RR_V2Confirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 1005 - Module
750 → 758 - Every
5 s - Testing for 2019 to 2024, 2026
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.8 bar
- Unit
- bar
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Rear right tire temperature UX_TT_RR
- Service 21
PID 16 - Module
750 → 758 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Rear right tire temperature UX_TT_RR_V2Confirmed
- Service 22
DID 1004 - Module
750 → 758 - Every
5 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x00 = 0 → = -40 °C
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Rear right wheel ABS status UX_RR_WHEEL_ABS_CTRL_STATUSConfirmed
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear right wheel EBS status UX_RR_WHEEL_EBD_CTRL_STATUSConfirmed
Electronic brakeforce distribution
- Service 21
PID 5F - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Rear right wheel stability control UX_RR_WHEEL_VSC_CTRLConfirmed
- Service 21
PID 5A - Module
7B0 → 7B8 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Spare tire pressure UX_TP_SPARE_V1Confirmed
- Service 21
PID 30 - Module
750 → 758 - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.896 bar
- Unit
- bar
Confirmed for 2023. In testing for 2019 to 2022, 2024, 2026. Not supported for 2025.
Spare tire pressure UX_TP_SPARE_V2Confirmed
- Service 22
DID 1005 - Module
750 → 758 - Every
5 s - Testing for 2019 to 2024, 2026
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 3.8 bar
- Unit
- bar
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Spare tire temperature UX_TT_SPARE
- Service 21
PID 16 - Module
750 → 758 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Spare tire temperature UX_TT_SPARE_V2Confirmed
- Service 22
DID 1004 - Module
750 → 758 - Every
5 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x00 = 0 → = -40 °C
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Tire 1 position UX_TID_1Confirmed
- Service 22
DID 2021 - Module
750 → 758 - Every
86400 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
0x02 = 2 → FR
| Raw value | State | Meaning |
|---|---|---|
1 | FL | Front left |
2 | FR | Front right |
3 | RL | Rear left |
4 | RR | Rear right |
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Tire 2 position UX_TID_2Confirmed
- Service 22
DID 2021 - Module
750 → 758 - Every
86400 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
0x01 = 1 → FL
| Raw value | State | Meaning |
|---|---|---|
1 | FL | Front left |
2 | FR | Front right |
3 | RL | Rear left |
4 | RR | Rear right |
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Tire 3 position UX_TID_3Confirmed
- Service 22
DID 2021 - Module
750 → 758 - Every
86400 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 16 to 23 of the reply, 8 bits.
- Unit
- Named states
0x04 = 4 → RR
| Raw value | State | Meaning |
|---|---|---|
1 | FL | Front left |
2 | FR | Front right |
3 | RL | Rear left |
4 | RR | Rear right |
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Tire 4 position UX_TID_4Confirmed
- Service 22
DID 2021 - Module
750 → 758 - Every
86400 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 24 to 31 of the reply, 8 bits.
- Unit
- Named states
0x03 = 3 → RL
| Raw value | State | Meaning |
|---|---|---|
1 | FL | Front left |
2 | FR | Front right |
3 | RL | Rear left |
4 | RR | Rear right |
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Tire pressure 1, set 2 UX_TIRE_P_1_SET_2
- Service 21
PID 15 - Module
750 → 758 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -0.5 to 3.89 bar
- Unit
- bar
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Tire pressure 2, set 2 UX_TIRE_P_2_SET_2
- Service 21
PID 15 - Module
750 → 758 - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -0.5 to 3.89 bar
- Unit
- bar
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Tire pressure 3, set 2 UX_TIRE_P_3_SET_2
- Service 21
PID 15 - Module
750 → 758 - Every
15 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -0.5 to 3.89 bar
- Unit
- bar
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Tire pressure 4, set 2 UX_TIRE_P_4_SET_2
- Service 21
PID 15 - Module
750 → 758 - Every
15 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -0.5 to 3.89 bar
- Unit
- bar
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Tire pressure 5, set 2 UX_TIRE_P_5_SET_2
- Service 21
PID 15 - Module
750 → 758 - Every
15 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- -0.5 to 3.89 bar
- Unit
- bar
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Torque converter turbine wheel speed UX_TQ_CONV_TURBINE_WHL
- Service 21
PID DA - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6 rpm
- Unit
- rpm
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Wheel cylinder pressure UX_WHEEL_CYLINDER_PRESSURE
- Service 21
PID 07 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Transmission
Boosting converter temperature, lower UX_BOOSTING_CONV_T_LOConfirmed
- Service 22
DID 10A7 - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x35 = 53 → = 13 °C
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Boosting converter temperature, upper UX_BOOSTING_CONV_T_HIConfirmed
- Service 22
DID 10A7 - Module
7D2 → 7DA - Every
5 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x35 = 53 → = 13 °C
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Current gear UX_GEAR_V2
- Service 21
PID DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
DC-DC converter output current UX_DC_DC_CONV_OUTPUT
- Service 22
DID 111C - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 199 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Gear UX_GEAR
- Service 21
PID 85 - Module
7E0 → 7E8 - Every
500 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 20
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Gear UX_GEAR_700
- Service 22
DID 1621 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Gear lock-up UX_GEAR_LOCKUP
Mechanism within the automatic transmission that momentarily locks the gears during gear changes, providing a smoother and more efficient transition between different gears, especially when accelerating or decelerating; essentially helps minimize power loss and jerkiness during gear shifts.
- Service 21
PID 85 - Module
7E0 → 7E8 - Every
500 ms - Testing
Bit 8 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Lock up state UX_AT_LOCK_UP_STATE
- Service 22
DID 1620 - Module
700 → 708 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Shift position UX_SHIFTConfirmed
- Service 22
DID 1061 - Module
7D2 → 7DA - Every
1 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
0x00 = 0 → P
| Raw value | State | Meaning |
|---|---|---|
0 | P | Park |
2 | R | Reverse |
4 | N | Neutral |
6 | D | Drive |
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Torque converter and TE1 on UX_TQ_CONV_TE1_ON
- Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission fluid post-converter temperature, variant 3 UX_TRANS_FLUID_POST_T_3
- Service 22
DID 1628 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission fluid temperature, pan var.3 UX_ATF_T_PAN_V3
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1627 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Transmission fluid temperature, variant 5 UX_ATF_T_V_5
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission fluid temperature, variant 8 UX_ATF_T_V_8
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission fluid temperature, variant 9 UX_ATF_T_V_9
- Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission fluid temperature, variant 10 UX_ATF_T_V_10_7E1
- Service 21
PID 82 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission fluid temperature, variant 11 UX_ATF_T_V_11
- Service 21
PID 82 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission fluid temperature, variant 12 UX_ATF_T_V_12
- Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission fluid temperature, variant 14 UX_ATF_T_V_14
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission fluid temperature, variant 14 UX_ATF_T_V_14_7E1
- Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission fluid temperature, variant 21 UX_ATF_T_V_21
- Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission fluid temperature, variant 21 UX_ATF_T_V_21_7E1
- Service 21
PID D9 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission oil pressure calibration, complete UX_TRANS_OIL_PRESS
- Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission shift state ratio UX_TRANS_SHIFT_ST_RAT
- Service 22
DID 1622 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.999
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Transmission temperature, pan UX_ATF_PAN_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Transmission temperature, torque converter UX_ATF_TQC_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Trips
Odometer UX_ENG_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 0103 - Module
700 → 708 - Every
30 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x00F940 = 63808 → 63,808 km
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Odometer UX_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 0103 - Module
747 → 74F - Every
10 s - Testing for 2019 to 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x002336 = 9014 → 9,014 km
Confirmed for 2025. In testing for 2019 to 2022, 2024, 2026. Not supported for 2023.
Odometer UX_ODO_1FA6Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 1FA6 - Module
7D2 → 7DA - Every
10 s - Testing for 2019 to 2022, 2024 to 2026
Example reply from a 2023 Lexus UX.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
0x0009BE9A = 638618 → = 63,861.8 km
Confirmed for 2023. In testing for 2019 to 2022, 2024 to 2026.
Odometer UX_ODO_7E0
Pelican can show this parameter as the odometer.
- Service 21
PID 28 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.
Odometer UX_ODO_V2Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 0103 - Module
7D2 → 7DA - Every
10 s - Testing for 2019 to 2022, 2024, 2026
Example reply from a 2025 Lexus UX.
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x002336 = 9014 → 9,014 km
Confirmed for 2023, 2025. In testing for 2019 to 2022, 2024, 2026.
Previous trip distance UX_PREV_TRIP_DST
- Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 km
- Unit
- km
In testing for 2019 to 2022, 2024, 2026. Not supported for 2023, 2025.