Lexus CT 200h

Parameters

The Lexus CT 200h has 668 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine coolant temperature CT200H_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 26
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255+1.3
Range
1.3 to 90.55 °C
Unit
°C

0x5D = 93 → 93×89.25255+1.3 = 33.85 °C

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

+BM voltage CT200H_BM_VConfirmed

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 56 to 71 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

0x2820 = 10272 → 10272×54096 = 12.539063 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

1st turbocharger outlet pressure, control valve CT200H_1ST_TRUBOCHARGER_P

  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

2nd turbocharger outlet pressure CT200H_2ND_TRUBOCHARGER_OUTLET_P

  • Service 22DID 11AF
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

2nd turbocharger outlet pressure, control valve CT200H_2ND_TRUBOCHARGER_P

  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Accumulated time of battery low CT200H_ACCUMULATED_TIME_BATConfirmed

  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Accumulated time of battery too high CT200H_ACCUMULATED_TIME_BAT_TOOConfirmed

  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 88 to 103 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Air fuel sensor voltage, bank 1 sensor 1 CT200H_AFS_VOLTAGE_B1S1Confirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×7.9965535
Range
0 to 7.99 V
Unit
V

0x9FFF = 40959 → 40959×7.9965535 = 4.993704 V

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Aux. battery capacity after IG OFF CT200H_AUX_BAT_CAP_AFTER_IG_OFF

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 Ah
Unit
Ah

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Aux. battery capacity after IG ON CT200H_AUX_BAT_CAP_AFTER_IG_ON

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 Ah
Unit
Ah

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Auxiliary battery temperature CT200H_AUXILIARY_BAT_TConfirmed

  • Service 21PID 41
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215
Unit
Number

0x4E = 78 → 78−40 = 38

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Auxiliary battery voltage CT200H_AUXILIARY_BAT_VConfirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 224 to 239 of the reply, 16 bits.

Formula
val×4738550−40
Range
-40 to 39.9 V
Unit
V

0xACD4 = 44244 → 44244×4738550−40 = 13.942101 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 1 voltage CT200H_BAT_BLOCK_V_V01Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2BC6 = 11206 → 11206×0.0012205692 = 13.677698 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 2 voltage CT200H_BAT_BLOCK_V_V02Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2BAE = 11182 → 11182×0.0012205692 = 13.648405 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 3 voltage CT200H_BAT_BLOCK_V_V03Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2B64 = 11108 → 11108×0.0012205692 = 13.558083 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 4 voltage CT200H_BAT_BLOCK_V_V04Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 48 to 63 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2B64 = 11108 → 11108×0.0012205692 = 13.558083 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 5 voltage CT200H_BAT_BLOCK_V_V05Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 64 to 79 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2B7C = 11132 → 11132×0.0012205692 = 13.587376 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 6 voltage CT200H_BAT_BLOCK_V_V06Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 80 to 95 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2B4B = 11083 → 11083×0.0012205692 = 13.527568 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 7 voltage CT200H_BAT_BLOCK_V_V07Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 96 to 111 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2B85 = 11141 → 11141×0.0012205692 = 13.598361 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 8 voltage CT200H_BAT_BLOCK_V_V08Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 112 to 127 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2B85 = 11141 → 11141×0.0012205692 = 13.598361 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 9 voltage CT200H_BAT_BLOCK_V_V09Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 128 to 143 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2B74 = 11124 → 11124×0.0012205692 = 13.577612 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 10 voltage, raw count CT200H_BAT_BLOCK_V_V10_RAWConfirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 144 to 159 of the reply, 16 bits.

Formula
val×79996553500
Range
0 to 79.99
Unit
Number

0x2B85 = 11141 → 11141×79996553500 = 13.598361

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 11 voltage CT200H_BAT_BLOCK_V_V11Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 160 to 175 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2BC6 = 11206 → 11206×0.0012205692 = 13.677698 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 12 voltage CT200H_BAT_BLOCK_V_V12Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 176 to 191 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2C00 = 11264 → 11264×0.0012205692 = 13.748491 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 13 voltage CT200H_BAT_BLOCK_V_V13Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 192 to 207 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2B4B = 11083 → 11083×0.0012205692 = 13.527568 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 14 voltage CT200H_BAT_BLOCK_V_V14Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 208 to 223 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2B74 = 11124 → 11124×0.0012205692 = 13.577612 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 16 voltage CT200H_BAT_BLOCK_V_V16Confirmed

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 240 to 255 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

0x0762 = 1890 → 189010 = 189 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block 17 voltage CT200H_BAT_BLOCK_V_V17

  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 256 to 271 of the reply, 16 bits.

Formula
val×79996553500
Range
0 to 79.99 V
Unit
V

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Battery block number with, maximum voltage CT200H_BAT_BLOCK_NUMBER_MAX_VConfirmed

  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 40 to 47 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

0x0B = 11 → 11+1 = 12

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block number with, minimum voltage CT200H_BAT_BLOCK_NUMBER_MIN_VConfirmed

  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

0x06 = 6 → 6+1 = 7

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block, maximum voltage CT200H_BAT_BLOCK_MAX_VConfirmed

  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 39 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2C8B = 11403 → 11403×0.0012205692 = 13.918151 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery block, minimum voltage CT200H_BAT_BLOCK_MIN_VConfirmed

  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0012205692
Range
0 to 79.99 V
Unit
V

0x2BD7 = 11223 → 11223×0.0012205692 = 13.698448 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery current CT200H_BAT_CURRENT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5013107−125
Range
-125 to 124.9 A
Unit
A

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Battery current CT200H_BAT_CURRENT_700

  • Service 22DID 15F7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4912850−125
Range
-125 to 124.9 A
Unit
A

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Battery status of full charge CT200H_BAT_STAT_FULL_CHG

  • Service 22DID 15E5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2552
Range
0 to 32512.5 Ah
Unit
Ah

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Battery temperature CT200H_BAT_T

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 6513.5 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Battery temperature CT200H_BAT_T_700

  • Service 22DID 15F8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Battery temperature CT200H_BAT_T_700_2

  • Service 22DID 1FF8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Battery voltage CT200H_12V_V_700

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1002
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12.20710000
Range
0 to 79 V
Unit
V

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Battery voltage CT200H_BAT_VConfirmed

  • Service 21PID 13
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x88 = 136 → 13610 = 13.6 V

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Battery voltage CT200H_BATTERY_VOLTAGEConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 184 to 199 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x3813 = 14355 → 143551000 = 14.355 V

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Charge contactor current CT200H_SCC_SOLENOID_CURRENTConfirmed

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

0x33 = 51 → 51 mA

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Charging integrated current of aux. battery CT200H_CHG_INTEGRATED

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2011. Supported for 2012, 2016.

Dark current of battery CT200H_DARK_CURRENT_BAT

  • Service 22DID 15E7
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Delta SOC CT200H_DELTA_SOCConfirmed

  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Discharging integrated current of aux. battery CT200H_DISCHARGING

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Distance since last battery cable disconnection CT200H_DIST_SINCE_BAT_DISC

  • Service 22DID 106C
  • Module700 → 708
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Engine control module control mode, driving control mode=1,current sensor offset mode=2,external charge control mode=3,power supply end mode=4 CT200H_ENG_CTRL_MODULE_CTRL_1_2_3_4Confirmed

  • Service 21PID 9B
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

High voltage battery charge control, kw CT200H_HVBAT_CHG_CTRL_KWConfirmed

  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5
Unit
Number

0x59 = 89 → 892−64 = -19.5

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

High voltage battery discharge control, kw CT200H_HVBAT_DCHG_CTRL_KWConfirmed

  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5
Unit
Number

0xAA = 170 → 1702−64 = 21

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

High voltage battery intake air temperature CT200H_HVBAT_IATConfirmed

  • Service 21PID 87
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0039047837−50
Range
-50 to 205 °C
Unit
°C

0x4257 = 16983 → 16983×0.0039047837−50 = 16.314942 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Initial engine battery voltage lower limit CT200H_INITIAL_ENG_BAT_V_LO

  • Service 22DID 15F6
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Input over-voltage to converter CT200H_OVERVOLTAGE_INPUTConfirmed

  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Input over-voltage to inverter CT200H_OVERVOLTAGE_INPUT_INVERTERConfirmed

  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Main connector solenoid current CT200H_SMC_SOLENOID_CURRENTConfirmed

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

0x00 = 0 → 0 mA

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Main relay a, solenoid current CT200H_SLA_SOLENOID_CURRENTConfirmed

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

0x00 = 0 → 0 mA

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Main relay r solenoid current CT200H_SLR_SOLENOID_CURRENTConfirmed

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

0x00 = 0 → 0 mA

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Number of battery blocks CT200H_NUM_BAT_BLOCKSConfirmed

  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x0E = 14 → 14

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Output speed sensor voltage CT200H_NOUT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Regenerative braking cooperation CT200H_REGEN_COOPERATIONConfirmed

  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Regenerative operation CT200H_FR_REGEN_OPERATIONConfirmed

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

0x0000 = 0 → 0 N·m

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Regenerative request CT200H_FR_REGEN_REQUESTConfirmed

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

0x0000 = 0 → 0 N·m

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Relay control solenoid current CT200H_SRC_SOLENOID_CURRENTConfirmed

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

0x00 = 0 → 0 mA

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Service contactor solenoid current CT200H_SSC_SOLENOID_CURRENTConfirmed

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

0x24 = 36 → 36 mA

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Sleep time of battery sensor CT200H_SLEEP_TIME_BATSENS

  • Service 22DID 15F0
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 h
Unit
h

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

SOC at ignition on CT200H_SOC_AFTER_IG_ONConfirmed

  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

0x60 = 96 → 962 = 48 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

SOC max CT200H_SOC_MAXConfirmed

  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 48 to 55 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

0x8B = 139 → 1392 = 69.5 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

SOC min CT200H_SOC_MINConfirmed

  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 56 to 63 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

0x5C = 92 → 922 = 46 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

State of charge, all bat CT200H_ST_CHG_ALL_BATConfirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 168 to 175 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

0x99 = 153 → 153×2051 = 60 %

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Turbine speed sensor voltage CT200H_NT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Vh-voltage after boosting CT200H_VH_V_AFTER_BOOSTING_7E2Confirmed

  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 56 to 71 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 V
Unit
V

0x01B3 = 435 → 4352 = 217.5 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Vl-voltage before boosting CT200H_VL_V_BEFORE_BOOSTING_7E2Confirmed

  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 40 to 55 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 V
Unit
V

0x01B6 = 438 → 4382 = 219 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Voltage of battery sensor CT200H_V_BATSENS

  • Service 22DID 15EE
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333310922500
Range
0 to 79.9979 V
Unit
V

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Climate

Adjusted ambient temperature CT200H_ADJUSTED_AMBIENT_TConfirmed

  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×81.6255−30.8
Range
-30.8 to 50.8 °C
Unit
°C

0x90 = 144 → 144×81.6255−30.8 = 15.28 °C

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Air inlet damper actual pulse CT200H_AIR_INLET_DAMPER_ACTUAL_PULSEConfirmed

  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x07 = 7 → 7

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Air inlet damper target pulse CT200H_AIR_INLET_DAMPER_TARGET_PULSEConfirmed

  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x07 = 7 → 7

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Air outlet servo actual pulse, driver CT200H_AIR_OUTLET_SERVO_ACTU_PULSE_DConfirmed

  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x25 = 37 → 37

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Air outlet servo pulse, driver CT200H_AIR_OUTLET_SERVO_PULSE_DConfirmed

  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x25 = 37 → 37

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Ambient air temperature CT200H_AAT_7C4Confirmed

  • Service 21PID 22
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255−23.3
Range
-23.3 to 65.95 °C
Unit
°C

0x6E = 110 → 110×89.25255−23.3 = 15.2 °C

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Ambient temperature CT200H_AMBIENT_T

  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Blower motor speed level CT200H_BLOWER_MOTOR_SPEED_LEVELConfirmed

  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Cabin temperature CT200H_CABIN_TConfirmed

  • Service 21PID 21
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×63.75255−6.5
Range
-6.5 to 57.25 °C
Unit
°C

0x55 = 85 → 85×63.75255−6.5 = 14.75 °C

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Communication with air conditioner CT200H_COMM_WITH_AIR_CONDITIONERConfirmed

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Communication with HV CT200H_COMMUNICATION_WITH_HVConfirmed

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Communication with valvematic CT200H_COMM_WITH_VALVEMATIC_COMMConfirmed

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Evaporator fin thermistor CT200H_EVAP_FIN_THERMISTORConfirmed

  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255−29.7
Range
-29.7 to 59.55 °C
Unit
°C

0x52 = 82 → 82×89.25255−29.7 = -1 °C

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Evaporator target temperature CT200H_EVAP_TARGET_TConfirmed

  • Service 21PID 4C
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−327.68
Range
-327.68 to 327.67
Unit
Number

0x814A = 33098 → 33098100−327.68 = 3.3

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Set temperature, driver side CT200H_T_DRIVERConfirmed

  • Service 21PID 29
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

0x20 = 32 → 32 °C

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Solar sensor, driver side CT200H_SOLAR_DRIVERConfirmed

  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2011. Supported for 2012, 2016.

Control

A/C compressor CT200H_A_C_COMPRESSOR

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bit 64 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2015, 2017 to 2022. Supported for 2011 to 2012, 2016.

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2012. Supported for 2011, 2016.

Accelerator pedal CT200H_ACCEL_PEDAL

  • Service 22DID 1059
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1.42−28.873
Range
0 to 100 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Anti-lock brake warning light CT200H_ABS_WARNConfirmed

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Brake warning light CT200H_BRAKE_WARNConfirmed

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Buzzer CT200H_BUZZERConfirmed

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Communication with brake CT200H_COMMUNICATION_WITH_BRAKEConfirmed

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Cruise control live brake cancel CT200H_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCHConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Electrical load signal 1 CT200H_ELECTRICAL_LOAD_SIGNAL_1Confirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Electrical load signal 2 CT200H_ELECTRICAL_LOAD_SIGNAL_2Confirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Electronically controlled brake warning light CT200H_ECB_WARNConfirmed

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Ignition trigger count CT200H_IGNITION_TRIG_CNTConfirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Key remind sound CT200H_KEY_REMIND_SOUND

  • Service 21PID A1
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Main idle CT200H_MAIN_IDLE_SWConfirmed

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Neutral position CT200H_NEUTRAL_POSITION_SW_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Supported for 2011 to 2012, 2016.

Parking brake CT200H_PARKING_BRAKE

  • Service 21PID 62
  • Module7D0 → 7D8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Parking brake CT200H_PARKING_BRAKE_SWConfirmed

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Pattern switch CT200H_PATTERN_SWITCH_PWR_M

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Supported for 2011 to 2012, 2016.

Power steering CT200H_POWER_STEERING_SIGNALConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Reservoir warning CT200H_RESERVOIR_WARNING_SWConfirmed

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Shift SW status, drive CT200H_SHIFT_SW_STATUS_D_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Supported for 2011 to 2012, 2016.

Shift SW status, neutral CT200H_SHIFT_SW_STATUS_N_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Supported for 2011 to 2012, 2016.

Shift SW status, parking CT200H_SHIFT_SW_STATUS_P_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Supported for 2011 to 2012, 2016.

Shift SW status, reverse CT200H_SHIFT_SW_STATUS_R_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Supported for 2011 to 2012, 2016.

Slip indicator light CT200H_SLIP_WARNConfirmed

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Sports mode selection CT200H_SPORTS_MODE_SELECTION_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Supported for 2011 to 2012, 2016.

Sports shift down CT200H_SPORTS_SHIFT_DOWN_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Supported for 2011 to 2012, 2016.

Sports shift up CT200H_SPORTS_SHIFT_UP_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Supported for 2011 to 2012, 2016.

Starter control CT200H_STARTER_CONTROLConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Starter signal CT200H_STARTER_SIGNALConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Steering angle CT200H_STEERING_ANGLE

  • Service 22DID 1004
  • Module7B3 → 7BB
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1.5
Range
-410 to 410 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Steering wheel angle CT200H_STEER_ANGLEConfirmed

Positive = counter-clockwise, negative = clockwise.

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 39 of the reply, 16 bits.

Formula
val10−3276.8
Range
-3276 to 3276 °
Unit
°

0x7E89 = 32393 → 3239310−3276.8 = -37.5 °

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

TC CT200H_TC_TERMINAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bit 61 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Supported for 2011 to 2012, 2016.

Traction control, brake status CT200H_TRC_TRAC__BRAKE_CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Cruise control

Cruise control speed CT200H_CC_S

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2012 to 2022

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2013 to 2015. Supported for 2011. Not supported for 2012, 2016.

Details

Inspection mode CT200H_INSPECTION_MODEConfirmed

  • Service 21PID A6
  • Module7B0 → 7B8
  • Every60 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

DTCs

2nd air monitor available? CT200H_2ND_AIR_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

2nd air monitor incomplete? CT200H_2ND_AIR_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

A/C monitor available? CT200H_A_C_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

A/C monitor incomplete? CT200H_A_C_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Catalyst monitor available? CT200H_CATALYST_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Catalyst monitor incomplete? CT200H_CATALYST_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Complete parts monitor available? CT200H_COMPLETE_PARTS_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2011 to 2012, 2016.

EGR/VVT monitor available? CT200H_EGR_VVT_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

EGR/VVT monitor incomplete? CT200H_EGR_VVT_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

EVAP monitor available? CT200H_EVAP_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

EVAP monitor_icmpl CT200H_EVAP_MONITOR_ICMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Fuel system monitor available? CT200H_FUEL_SYSTEM_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Heated catalyst monitor available? CT200H_HEATED_CATALYST_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Heated catalyst monitor incomplete? CT200H_HEATED_CATALYST_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

MIL CT200H_MILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

MIL ON run distance CT200H_MILON_RUN_DISTANCEConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Misfire monitor available? CT200H_MISFIRE_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Number of emission DTC CT200H_NUMBER_OF_EMISSION_DTCConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

0b0000000 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

O2S heater monitor available? CT200H_O2S_A_FS_HEATER_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

O2S heater monitor incomplete? CT200H_O2S_A_FS_HEATER_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

O2S monitor available? CT200H_O2S_A_FS_MONITOR_AVAILConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

O2S monitor incomplete? CT200H_O2S_A_FS_MONITOR_INCMPLConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Running time from MIL ON CT200H_RUNNING_TIME_FROM_MIL_ONConfirmed

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

0x0007 = 7 → 7 min

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

ECU

VVT-ie duty ratio bank 1 CT200H_VVT_IE_DUTY_RATIO_1

  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 14 of the reply, 15 bits.

Formula
val×399.965535−200
Range
-200 to -0.0531 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

VVT-ie motor direction: forward bank 1 CT200H_VVT_IE_MOTOR_DIRECTION_FORWARD_1

  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Engine

+B CT200H_BConfirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 152 to 167 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

0x36B3 = 14003 → 140031000 = 14.003 V

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

A/C gate status CT200H_AIRCON_GATE_STATConfirmed

  • Service 21PID 75
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

A/F heater duty bank 1 sensor 1 CT200H_F_HEATER_DUTY_B1S1Confirmed

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

0x0000 = 0 → 0×254096 = 0 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

A/F ratio learn value high, bank 1 CT200H_AF_LEARN_HIGH_PORT_B1

  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

A/F ratio learn value idle, bank 1 CT200H_AF_LEARN_IDLE_PORT_B1

  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

A/F ratio learn value low, bank 1 CT200H_AF_LEARN_LOW_PORT_B1

  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

A/F ratio learn value mid.1, bank 1 CT200H_AF_LEARN_MID1_PORT_B1

  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

A/F ratio learn value mid.2, bank 1 CT200H_AF_LEARN_MID2_PORT_B1

  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

A/F ratio learned high, bank 1 CT200H_A_F_RATIO_LEARNED_HIGH_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

A/F ratio learned idle, bank 1 CT200H_A_F_RATIO_LEARNED_IDLE_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

A/F ratio learned low, bank 1 CT200H_A_F_RATIO_LEARNED_LOW_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

A/F ratio learned mid 1, bank 1 CT200H_A_F_RATIO_LEARNED_MID_1_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

A/F ratio learned mid 2, bank 1 CT200H_A_F_RATIO_LEARNED_MID_2_BANK_1

  • Service 22DID 102A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255−50
Range
-50 to 50 %
Unit
%

In testing for 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

A/F test results 1, incomplete CT200H_F_TEST_RESULTS_1Confirmed

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2016. Supported for 2011 to 2012.

Accessory relay on CT200H_ACC_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Accumulated time of DC inhibit CT200H_ACCUMULATED_TIME_DCConfirmed

  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 72 to 87 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Accumulated time of hot temperature CT200H_ACCUMULATED_TIME_HOT_TConfirmed

  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Accumulator open CT200H_ACCUMULATOR_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Acoustic control induction system vacuum switching valve on CT200H_ACIS_VSV_ONConfirmed

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Actual engine torque CT200H_ACT_ENG_TQConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 39 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767 N·m
Unit
N·m

0x8000 = 32768 → 32768−32768 = 0 N·m

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Actuator power supply on CT200H_ACTUATOR_POWER_SUP_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bit 146 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

AF lambda, bank 1 sensor 1 CT200H_AF_LAMBDA_B1S1Confirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 16 to 31 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Air conditioning compressor CT200H_AC_COMP

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Air conditioning consumption power, w CT200H_AC_CONS_POWER_WConfirmed

  • Service 21PID 7D
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750
Unit
Number

0x00 = 0 → 0×50 = 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2011. Supported for 2012, 2016.

Air fuel sensor current, bank 1 sensor 1 CT200H_AFS_CURRENT_B1S1Confirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 64 to 79 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.99 mA
Unit
mA

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Air mix servo target pulse, driver CT200H_AIR_MIX_SERVO_TARG_DConfirmed

  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x1D = 29 → 29

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Air mix servo, actual pulse, d CT200H_AIR_MIX_SERVO_ACT_DConfirmed

  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x1D = 29 → 29

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Alt voltage - active test CT200H_ALT_VOL_ACTIVE_TEST

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Alt voltage - non active test CT200H_ALT_VOL_NON_ACTIVE

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Alternator output duty CT200H_ALTERNATOR_OUTPUT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Alternator output duty cycle CT200H_ALT_DUTY_CYCLE

  • Service 22DID 15FA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val164
Range
0 to 399 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Ambient temperature CT200H_AAT_7E2Confirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x47 = 71 → 71−40 = 31 °C

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Atmosphere pressure CT200H_ATMOSPHERE_PRESSUREConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

0x60 = 96 → 96 kPa

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Atmosphere pressure_7e2 CT200H_ATMOSPHERE_P_7E2Confirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

0x62 = 98 → 98 kPa

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Automatic transmission fluid thermal degradation estimate CT200H_ATF_THERMAL_DEGRAD_EST

  • Service 22DID 162B
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Battery pack current CT200H_BATT_PACK_CURRENTConfirmed

  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10−327680
Range
-327680 to 327670 mA
Unit
mA

0x6158 = 24920 → 24920×10−327680 = -78,480 mA

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery temperature TB1 CT200H_T_BATT_TB1Confirmed

  • Service 21PID 87
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0039047837−50
Range
-50 to 205 °C
Unit
°C

0x45D9 = 17881 → 17881×0.0039047837−50 = 19.821437 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery temperature TB2 CT200H_T_BATT_TB2Confirmed

  • Service 21PID 87
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.0039047837−50
Range
-50 to 205 °C
Unit
°C

0x48D1 = 18641 → 18641×0.0039047837−50 = 22.789073 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Battery temperature TB3 CT200H_T_BATT_TB3Confirmed

  • Service 21PID 87
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 48 to 63 of the reply, 16 bits.

Formula
val×0.0039047837−50
Range
-50 to 205 °C
Unit
°C

0x4635 = 17973 → 17973×0.0039047837−50 = 20.180677 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Boost ratio CT200H_BOOST_RATConfirmed

  • Service 21PID 7D
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2011 to 2012, 2016.

Calculated load CT200H_CALCULATED_LOAD_7E0Confirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Calculated load_7e2 CT200H_CALC_LOAD_7E2Confirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×2051 = 0 %

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Cancel switch CT200H_CANCEL_SWITCHConfirmed

  • Service 21PID 21
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Catalyst temperature B1S1 CT200H_CATALYST_T_B1S1Confirmed

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 31 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x1D43 = 7491 → 749110−40 = 709.1 °C

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Catalyst temperature B1S2 CT200H_CATALYST_T_B1S2Confirmed

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 47 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x1C4F = 7247 → 724710−40 = 684.7 °C

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Catalyst temperature bank 2 sensor 1 CT200H_CAT_T_BANK_2_SENS_1

  • Service 22DID 1F3D
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Catalyst temperature bank 2 sensor 2 CT200H_CAT_T_BANK_2_SENS_2

  • Service 22DID 1F3F
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Catalyst temperature, bank 1 sensor 1 CT200H_CAT_T_BANK_1_SENSOR_1

  • Service 22DID 1F3C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Catalyst temperature, bank 1 sensor 2 CT200H_CAT_T_BANK_1_SENSOR_2

  • Service 22DID 1F3E
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Catalyst temperature, bank 1 sensor 2, variant 2 CT200H_CAT_T_B1S2_V2

  • Service 21PID 3E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Check mode on CT200H_CHECK_MODE_ONConfirmed

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Closed throttle position switch on CT200H_CLOSED_THROTTLE_POS_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bit 125 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Codes, include history CT200H_CODES_INCLUDEConfirmed

  • Service 21PID E1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2011 to 2012, 2016.

Continuously variable transmission learning complete CT200H_CVT_LEARNED

  • Service 21PID DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Continuously variable transmission oil pressure CT200H_CVT_OIL_P

  • Service 21PID BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200 kPa
Unit
kPa

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Coolant temp CT200H_COOLANT_TEMPConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x7F = 127 → 127−40 = 87 °C

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Coolant water route switching valve 1, closed? CT200H_COOLANT_VALVE_1_CLOSE

  • Service 22DID 282C
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Coolant water route switching valve 2, closed? CT200H_COOLANT_VALVE_2_CLOSE

  • Service 22DID 2847
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Cooling fan 0 CT200H_COOLING_FAN_0Confirmed

  • Service 21PID 8E
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Cooling fan duty ratio CT200H_COOLING_FAN_DUTY_RATIO

  • Service 22DID 1046
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×127.5255
Range
0 to 127.5 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Cooling fan mode 1 CT200H_COOLING_FAN_MODE_1Confirmed

  • Service 21PID 9B
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Cooling fan relay status CT200H_COOLING_FAN_RELAYConfirmed

  • Service 21PID 8E
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Cruise control CT200H_CRUISE_CTRLConfirmed

  • Service 21PID 21
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Cruise control on CT200H_CRUISE_CTRL_ON

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Cruise control remembered vehicle speed CT200H_CCS_MEM_VEH_SPDConfirmed

  • Service 21PID 21
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Cruise control vehicle speed CT200H_CCS_VEH_SPDConfirmed

  • Service 21PID 21
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Cruise operation status CT200H_CRUISE_OPERATIONConfirmed

  • Service 21PID 21
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Cruise resume and accelerate switch CT200H_RES_ACC_SWITCHConfirmed

  • Service 21PID 21
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Cylinder 1 injection volume CT200H_CYL_1_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Cylinder 2 injection volume CT200H_CYL_2_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Cylinder 3 injection volume CT200H_CYL_3_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Cylinder 4 injection volume CT200H_CYL_4_INJ_VOLUME

  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Cylinder number CT200H_CYLINDER_NUMBERConfirmed

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011, 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x04 = 4 → 4

Confirmed for 2012, 2016. In testing for 2011, 2013 to 2015, 2017 to 2022.

DC/DC converter, target pulse duty CT200H_DCDC_CNV_TGT_DUTYConfirmed

  • Service 21PID 79
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333218450
Range
0 to 399 %
Unit
%

0x1B4E = 6990 → 6990×1333218450 = 42.653559 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Destination CT200H_DESTINATIONConfirmed

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011, 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x41 = 65 → 65

Confirmed for 2012, 2016. In testing for 2011, 2013 to 2015, 2017 to 2022.

Dist battery cable disconnect CT200H_DIST_BATT_CABLEConfirmed

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0DE8 = 3560 → 3,560 km

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

DTC clear min, raw count CT200H_DTC_CLEAR_MIN_RAWConfirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 136 to 151 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x1957 = 6487 → 6,487

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

DTC clear warm up CT200H_DTC_CLEAR_WARM_UPConfirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xB3 = 179 → 179

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Electric fan motor on CT200H_ELEC_FAN_MOTOR_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Electric thermostat duty ratio CT200H_ELECTRIC_THERMOSTAT_DUTY_RATIO

  • Service 22DID 2829
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Electric water pump CT200H_ELECTRIC_WATER_PUMP

  • Service 22DID 2827
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200 rpm
Unit
rpm

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Electric water pump RPM CT200H_EWP_RPM

  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Electric water pump target speed CT200H_EWP_TARGET_VSS

  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Engine control module code, raw count CT200H_ENG_CTRL_MODULE_CODE

  • Service 21PID C2
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 154,160 to 154,167 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Engine coolant temperature CT200H_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 26
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×89.25255+1.3
Range
1.3 to 90.55 °C
Unit
°C

0x5D = 93 → 93×89.25255+1.3 = 33.85 °C

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Engine coolant temperature CT200H_ECT_7C0Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 23
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

0x45 = 69 → 692 = 34.5 °C

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2011 to 2012, 2016.

Engine coolant temperature_7e2 CT200H_ECT_7E2Confirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x81 = 129 → 129−40 = 89 °C

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Engine coolant temperature, at ignition CT200H_ECT_IGN

  • Service 22DID 1041
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×62.5100−40
Range
-40 to 119.375 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Engine coolant temperature, initial CT200H_ECT_INIT

  • Service 22DID 1041
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×62.5100−40
Range
-40 to 119.375 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Engine independent CT200H_ENG_INDEPENDENTConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 91 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Engine independent control CT200H_ENG_INDEPENDENT_CTRLConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Engine oil temperature CT200H_EOT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Engine oil temperature CT200H_EOT_700

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 107B
  • Module700 → 708
  • Every5 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Engine rev, sensor CT200H_ENG_REV_SENSConfirmed

  • Service 21PID 41
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 40 to 55 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Engine run time CT200H_ENG_RUN_TIMEConfirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 72 to 87 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x0491 = 1169 → 1,169 s

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Engine run time CT200H_ENGINE_RUN_TIMEConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x0568 = 1384 → 1,384 s

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Engine run time, up to 255 sec. only CT200H_ENG_RUN_TIME_UP_255Confirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

0x00 = 0 → 0 s

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Engine stall control FB flow CT200H_ENG_STALL_CTRL_FB

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096−40
Range
-40 to 39.99
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

EVAP purge duty CT200H_EVAP_PURGE_DUTYConfirmed

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Evaporative purge duty CT200H_EVAP_PURGE_DUTY_7E0

  • Service 21PID 2E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Evaporative purge flow CT200H_EVAP_PURGE_FLOWConfirmed

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.99 %
Unit
%

0x0000 = 0 → 0×254096 = 0 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Evaporative purge vacuum switching valve on CT200H_EVAP_PURGE_VSV_ONConfirmed

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Exhaust gas recirculation step position CT200H_EGR_STEP_POSITIONConfirmed

  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Exhaust gas recirculation temperature CT200H_EGR_T

  • Service 21PID ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5385
Range
0 to 159 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Exhaust gas recirculation valve step CT200H_EGR_STEP

  • Service 21PID E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Exhaust VVT change angle, bank 1 CT200H_EXHAUST_VVT_ANGLE_B1

  • Service 22DID 1088
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Exhaust VVT hold learn value, bank 1 CT200H_EXHAUST_VVT_HOLD_LEARN_B1

  • Service 22DID 1089
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×399.965535
Range
0 to 399.9 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Exhaust VVT timing most over-advanced learn value, bank 1 CT200H_EXHAUST_VVT_OVER_ADV_LEARN_B1

  • Service 22DID 108F
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.9965535
Range
0 to 639.99 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Fuel cut for engine stop request CT200H_F_C_ENG_STOP_REQConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 92 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Fuel cut TAU on CT200H_FC_TAU_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Fuel filter temperature CT200H_FFT

  • Service 22DID 109A
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

G sensor calibration, complete CT200H_G_SENS_CALIBRATION

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

G sensor learning value CT200H_G_SENS_LEARNING

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Glass humidity CT200H_GLASS_HUMIDITY

  • Service 21PID B1
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2013107
Range
0 to 100 %
Unit
%

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Glass temperature CT200H_GLASS_T

  • Service 21PID AF
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9500−557.8
Range
-557 to 621 °F
Unit
°F

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Hydraulic valve, communication open CT200H_HV_COMM_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

ICE, actual torque CT200H_ICE_ACT_TQ

  • Service 21PID CD
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.000051319−128.006569
Range
-128 to 127 N·m
Unit
N·m

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Idle control CT200H_IDLE_CTRL

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Idle spark advance control 1 CT200H_IDLE_SPARK_ADVN_CTRL_1

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Idle spark advance control 2 CT200H_IDLE_SPARK_ADVN_CTRL_2

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Idle spark advance control 3 CT200H_IDLE_SPARK_ADVN_CTRL_3

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Idle spark advance control 4 CT200H_IDLE_SPARK_ADVN_CTRL_4

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Idle spark advance control, cylinder 1 CT200H_IDLE_SAC_CYL_1

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Idle spark advance control, cylinder 2 CT200H_IDLE_SAC_CYL_2

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Idle spark advance control, cylinder 3 CT200H_IDLE_SAC_CYL_3

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Idle spark advance control, cylinder 4 CT200H_IDLE_SAC_CYL_4

  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×6.25100
Range
0 to 15.9375 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Idle speed control learning CT200H_IDLE_SPD_CTRLConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 93 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Idle speed control learning value, l/s CT200H_IDLE_SPD_CTRL_L_SConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 72 to 87 of the reply, 16 bits.

Formula
val×0.0012206912
Range
0 to 79.99
Unit
Number

0x09C5 = 2501 → 2501×0.0012206912 = 3.052949

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

IG OFF elapsed time CT200H_IG_OFF_ELAPSED_TIMEConfirmed

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 80 to 95 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 min
Unit
min

0x0060 = 96 → 96×10 = 960 min

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Ignition advance CT200H_SPARKADV_21

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Ignition timing advance CT200H_IGN_ADVANCEConfirmed

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

0x8A = 138 → 1382−64 = 5 °

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Immobilizer communication on CT200H_IMMOBILIZER_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bit 120 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Initial engine coolant temperature CT200H_INITIAL_ECTConfirmed

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×531850−40
Range
-40 to 119.3
Unit
Number

0x57 = 87 → 87×531850−40 = 14.349412

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Initial intake air temperature CT200H_INITIAL_IATConfirmed

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

0x5A = 90 → 90×58−40 = 16.25 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Injection CT200H_INJECTION

  • Service 22DID 1019
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1DIRECTDirect
2BOTHBoth

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Injection duration for cylinder 1 CT200H_INJ_DUR_CYL_1Confirmed

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

0x0000 = 0 → 01000 = 0 ms

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Injection feedback value 1 CT200H_INJ_FEEDBACK_1

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection feedback value 1 CT200H_INJ_FEEDBACK_1_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection feedback value 2 CT200H_INJ_FEEDBACK_2

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection feedback value 2 CT200H_INJ_FEEDBACK_2_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection feedback value 3 CT200H_INJ_FEEDBACK_3

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection feedback value 3 CT200H_INJ_FEEDBACK_3_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection feedback value 4 CT200H_INJ_FEEDBACK_4

  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×532−20
Range
-20 to 15
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection feedback value 4 CT200H_INJ_FEEDBACK_4_700

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection feedback value 5 CT200H_INJ_FEEDBACK_5

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection feedback value 6 CT200H_INJ_FEEDBACK_6

  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×3322125−19.99811765
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection volume CT200H_INJ_VOL

  • Service 22DID 1017
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val3200
Range
0 to 20.4 L
Unit
L

In testing for 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Injection volume - target CT200H_INJ_VOLUME_TGT

  • Service 22DID 112C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000
Range
0 to 15
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection volume 1 CT200H_INJ_VOLUME_1

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection volume 2 CT200H_INJ_VOLUME_2

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection volume 3 CT200H_INJ_VOLUME_3

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection volume 5 CT200H_INJ_VOLUME_5

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection volume 6 CT200H_INJ_VOLUME_6

  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-40 to 300
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injection volume per 10 injections, cylinder 1 CT200H_INJ_VOL_CYL_1Confirmed

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val32000000
Range
0 to 0.002 L
Unit
L

0x0000 = 0 → 032000000 = 0 L

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Injection volume total CT200H_INJ_VOLUME_TOT

  • Service 22DID 112F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×195311000000−640
Range
-640 to 15
Unit
Raw value

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Injector port CT200H_INJECTOR_PORT

  • Service 22DID 1018
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Injector pulse width CT200H_INJ_PW

  • Service 21PID E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1631275
Range
0 to 32.6 ms
Unit
ms

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Injector pulse width CT200H_INJ_WIDTH

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Input shaft speed CT200H_SPD_NIN

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Intake air CT200H_INTAKE_AIRConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x4B = 75 → 75−40 = 35 °C

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Intake air temperature CT200H_IAT_21

  • Service 21PID 0F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Intake air temperature_7e2 CT200H_IAT_7E2Confirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x50 = 80 → 80−40 = 40 °C

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Intake air temperature, bank 1 sensor 1 CT200H_IAT_B1S1

  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Intake air temperature, bank 1 sensor 2 CT200H_IAT_B1S2

  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Intake VVT change angle bank 1 CT200H_INTAKE_VVT_CHANGE_ANGLE_BANK_1

  • Service 22DID 1087
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Intake VVT most over-retarded learn value, bank 1 CT200H_INTAKE_VVT_OVER_RET_LEARN_B1

  • Service 22DID 108D
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.9965535
Range
0 to 639.99 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Intake VVT target angle B1 CT200H_INTAKE_VVT_TARGET_ANGLE_B1

  • Service 22DID 106F
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×639.965535
Range
0 to 639.9 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Integrated engine run time CT200H_INTEGRATED_ENG_RUN

  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Intercooler coolant temperature CT200H_INTERCOOLER_ECT

  • Service 22DID 119C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Intercooler water pump CT200H_INTERCOOLER_WATER

  • Service 22DID 2820
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8013107
Range
0 to 300 %
Unit
%

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Internal resistance R01 CT200H_INTERNAL_RES_R01Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x13 = 19 → 191000 = 0.019 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R02 CT200H_INTERNAL_RES_R02Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x13 = 19 → 191000 = 0.019 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R03 CT200H_INTERNAL_RES_R03Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x13 = 19 → 191000 = 0.019 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R04 CT200H_INTERNAL_RES_R04Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x13 = 19 → 191000 = 0.019 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R05 CT200H_INTERNAL_RES_R05Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 39 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x12 = 18 → 181000 = 0.018 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R06 CT200H_INTERNAL_RES_R06Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 40 to 47 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x12 = 18 → 181000 = 0.018 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R07 CT200H_INTERNAL_RES_R07Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 48 to 55 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x12 = 18 → 181000 = 0.018 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R08 CT200H_INTERNAL_RES_R08Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 56 to 63 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x13 = 19 → 191000 = 0.019 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R09 CT200H_INTERNAL_RES_R09Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 64 to 71 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x13 = 19 → 191000 = 0.019 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R10 CT200H_INTERNAL_RES_R10Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 72 to 79 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x13 = 19 → 191000 = 0.019 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R11 CT200H_INTERNAL_RES_R11Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 80 to 87 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x13 = 19 → 191000 = 0.019 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R12 CT200H_INTERNAL_RES_R12Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 88 to 95 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x13 = 19 → 191000 = 0.019 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R13 CT200H_INTERNAL_RES_R13Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 96 to 103 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x13 = 19 → 191000 = 0.019 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R14 CT200H_INTERNAL_RES_R14Confirmed

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 104 to 111 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

0x13 = 19 → 191000 = 0.019 Ω

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Internal resistance R15 CT200H_INTERNAL_RES_R15

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 112 to 119 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Internal resistance R16 CT200H_INTERNAL_RES_R16

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 120 to 127 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Internal resistance R17 CT200H_INTERNAL_RES_R17

  • Service 21PID 95
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 128 to 135 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 Ω
Unit
Ω

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Inverter coolant temperature CT200H_INVERTER_ECTConfirmed

  • Service 21PID 75
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215
Unit
Number

0x51 = 81 → 81−40 = 41

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Inverter MG1 temperature CT200H_INVERTER_MG1_TConfirmed

  • Service 21PID 70
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x37 = 55 → 55−40 = 15 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Inverter MG1 temperature at ignition on CT200H_INVERTER_MG1_T_AFTER_ONConfirmed

  • Service 21PID 70
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x37 = 55 → 55−40 = 15 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Inverter MG1 temperature max CT200H_INVERTER_MG1_T_MAXConfirmed

  • Service 21PID 70
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3F = 63 → 63−40 = 23 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Inverter MG2 temperature CT200H_INVERTER_MG2_TConfirmed

  • Service 21PID 71
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x37 = 55 → 55−40 = 15 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Inverter MG2 temperature at ignition on CT200H_INVERTER_MG2_T_AFTER_ONConfirmed

  • Service 21PID 71
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x37 = 55 → 55−40 = 15 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Inverter MG2 temperature max CT200H_INVERTER_MG2_T_MAXConfirmed

  • Service 21PID 71
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3C = 60 → 60−40 = 20 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Inverter water pump revolution CT200H_INVERTER_WATER_PMP_REVOLUTIONConfirmed

  • Service 21PID 75
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0D2F = 3375 → 3,375 rpm

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Judge time engine ignition CT200H_JUDGE_TIME_ENG_IGNConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 56 to 63 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

0x00 = 0 → 010 = 0 s

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Judge time engine output CT200H_JUDGE_TIME_ENGConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

0x00 = 0 → 010 = 0 s

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Knock adjust CT200H_KNOCK_ADJUST

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 0 to 15 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Knock adjust CT200H_KNOCK_ADJUST_7E0Confirmed

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

0x7FA0 = 32672 → 32672×204865535−1024 = -2.984421 °

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Knock correct learn value CT200H_KNOCK_CORRECT_LEARNConfirmed

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 31 of the reply, 16 bits.

Formula
val32−1024
Range
-1024 to 1023 °
Unit
°

0x82A5 = 33445 → 3344532−1024 = 21.15625 °

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Knock correction, learned value CT200H_KNOCK_CORRECT_LEARNED_VALUE

  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×312.510000−1024
Range
-1024 to 1023
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Knock feedback CT200H_KNOCK_FEEDBACK

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 16 to 31 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Knock feedback CT200H_KNOCK_FEEDBACK_7E0Confirmed

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 48 to 63 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Knock feedback value CT200H_KNOCK_FEEDBACK_VALUE

  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×312.510000−1024
Range
-1024 to 1023
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Lock up state CT200H_LOCK_UP_STATE

  • Service 22DID 1620
  • Module701 → 709
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Long FT B1S1 CT200H_LONG_FT_B1S1Confirmed

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.218 %
Unit
%

0x83 = 131 → 131×200256−100 = 2.34375 %

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Long-term fuel trim, bank 1 CT200H_LTFT1_21

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.7809803922−100
Range
-100 to 99.15 %
Unit
%

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Manifold absolute pressure CT200H_MAPConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

0x60 = 96 → 96 kPa

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Manifold air pressure_7e2 CT200H_MANIFOLD_AIR_P_7E2Confirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

0x2D = 45 → 45 kPa

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Mass air flow CT200H_MAFConfirmed

Pelican can show this parameter as the mass air flow.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 39 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

0x0012 = 18 → 18100 = 0.18 g/s

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Mass air flow CT200H_MAF_21

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 g/s
Unit
g/s

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Master cylinder open CT200H_MASTER_CYLINDER_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

MG1 carrier frequency CT200H_MG1_CARRIERConfirmed

  • Service 21PID 7C
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 Hz
Unit
Hz

0x4B = 75 → 75×50 = 3,750 Hz

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG1 control mode, pwm=0,variable pwm=1,rectangular wave=2 CT200H_MG1_CTRL_MODE_PWM_0_1_2Confirmed

  • Service 21PID 67
  • Module7E2 → 7EA
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG1 gate status CT200H_MG1_GATE_STATConfirmed

  • Service 21PID 70
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG1 inverter fail CT200H_MG1_INVERTER_FAILConfirmed

  • Service 21PID 78
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG1 inverter shutdown CT200H_MG1_INVERTERConfirmed

  • Service 21PID 78
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG1 revolution CT200H_MG1_REVOLUTIONConfirmed

  • Service 21PID 61
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 39 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767 rpm
Unit
rpm

0x8000 = 32768 → 32768−32768 = 0 rpm

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG1 temperature CT200H_MG1_TConfirmed

  • Service 21PID 61
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x39 = 57 → 57−40 = 17 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG1 temperature at ignition on CT200H_MG1_T_AFTER_IG_ONConfirmed

  • Service 21PID 61
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x36 = 54 → 54−40 = 14 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG1 temperature max CT200H_MG1_T_MAXConfirmed

  • Service 21PID 61
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x39 = 57 → 57−40 = 17 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG1 torque CT200H_MG1_TQ_7E2Confirmed

  • Service 21PID 67
  • Module7E2 → 7EA
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−4096
Range
-4096 to 4095 N·m
Unit
N·m

0x7EC4 = 32452 → 324528−4096 = -39.5 N·m

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG1 torque execution value CT200H_MG1_TQ_EXECUTIONConfirmed

  • Service 21PID 67
  • Module7E2 → 7EA
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 31 of the reply, 16 bits.

Formula
val8−4096
Range
-4096 to 4095 N·m
Unit
N·m

0x7F01 = 32513 → 325138−4096 = -31.875 N·m

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG2 carrier frequency CT200H_MG2_CARRIERConfirmed

  • Service 21PID 7C
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 Hz
Unit
Hz

0x0F = 15 → 15×50 = 750 Hz

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG2 control mode, pwm=0,variable pwm=1,rectangular wave=2 CT200H_MG2_CTRL_MODE_PWM_0_1_2Confirmed

  • Service 21PID 68
  • Module7E2 → 7EA
  • Every250 ms
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

MG2 gate status CT200H_MG2_GATE_STATConfirmed

  • Service 21PID 71
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG2 inverter fail CT200H_MG2_INVERTER_FAILConfirmed

  • Service 21PID 78
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG2 inverter shutdown CT200H_MG2_INVERTERConfirmed

  • Service 21PID 78
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG2 revolution CT200H_MG2_REVOLUTIONConfirmed

  • Service 21PID 62
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 39 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767 rpm
Unit
rpm

0x8000 = 32768 → 32768−32768 = 0 rpm

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG2 temperature CT200H_MG2_TConfirmed

  • Service 21PID 62
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x37 = 55 → 55−40 = 15 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG2 temperature at ignition on CT200H_MG2_T_AFTER_IG_ONConfirmed

  • Service 21PID 62
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x36 = 54 → 54−40 = 14 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG2 temperature max CT200H_MG2_T_MAXConfirmed

  • Service 21PID 62
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x39 = 57 → 57−40 = 17 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

MG2 torque CT200H_MG2_TQ_7E2Confirmed

  • Service 21PID 68
  • Module7E2 → 7EA
  • Every250 ms
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−4096
Range
-4096 to 4095 N·m
Unit
N·m

0x7D21 = 32033 → 320338−4096 = -91.875 N·m

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

MG2 torque execution value CT200H_MG2_TQ_EXECUTIONConfirmed

  • Service 21PID 68
  • Module7E2 → 7EA
  • Every250 ms
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 31 of the reply, 16 bits.

Formula
val8−4096
Range
-4096 to 4095 N·m
Unit
N·m

0x7D3B = 32059 → 320598−4096 = -88.625 N·m

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Misfire load CT200H_MISFIRE_LOAD

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×510255
Range
0 to 510 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Misfire margin CT200H_MISFIRE_MARGIN

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 rpm
Unit
rpm

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Misfire RPM CT200H_MISFIRE_RPM

  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×6375255
Range
0 to 6375 rpm
Unit
rpm

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Misfire RPM CT200H_MISFIRE_RPM_7E0Confirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

0x00 = 0 → 0×25 = 0 rpm

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Misfire test result, incomplete CT200H_MIS_TEST_RESULTConfirmed

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Misfire, all cylinders counter CT200H_MISFIRE_COUNT

  • Service 22DID 10A5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Model year CT200H_MODEL_YEARConfirmed

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011, 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 128 to 135 of the reply, 8 bits.

Formula
val+1900
Range
1900 to 2155
Unit
Number

0x73 = 115 → 115+1900 = 2,015

Confirmed for 2012, 2016. In testing for 2011, 2013 to 2015, 2017 to 2022.

Number of current code CT200H_NUM_CURRENT_CODEConfirmed

  • Service 21PID E1
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Number of history code CT200H_NUM_HISTORY_CODEConfirmed

  • Service 21PID E1
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

O2 heater b1s2_active CT200H_O2_HEATER_B1S2Confirmed

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 68 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

O2 heater current val bank 1 sensor 2 CT200H_O2_HEATER_CURR_VALConfirmed

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 48 to 63 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 A
Unit
A

0x0000 = 0 → 013107 = 0 A

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

O2S, bank 1 sensor 2 CT200H_O2S_B1S2Confirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 80 to 87 of the reply, 8 bits.

Formula
val×51000
Range
0 to 1.275 V
Unit
V

0x07 = 7 → 7×51000 = 0.035 V

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Open side malfunction on CT200H_OPEN_SIDE_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bit 145 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Output shaft speed CT200H_SPD_NOUT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

OXS1, A/FS2 test result, incomplete CT200H_OXS1_FS2_TEST_RESULTConfirmed

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Oxygen sensor voltage, bank 1 sensor 1 CT200H_O2S11_V

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.0049960784
Range
0 to 1.27 V
Unit
V

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Park position switch terminal voltage CT200H_P_POS_SW_TERMINALConfirmed

  • Service 21PID 41
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 56 to 63 of the reply, 8 bits.

Formula
val×0.3137207031
Range
0 to 79.99 V
Unit
V

0x85 = 133 → 133×0.3137207031 = 41.724854 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

PM accumulation ratio - bank 1 CT200H_PM_ACCUMULATION_RAT_1

  • Service 22DID 1105
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 15 %
Unit
%

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Power resource IB CT200H_POWER_RESOURCE_IBConfirmed

  • Service 21PID 8A
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10−327.68
Range
-327 to 655022 mA
Unit
mA

0x60CA = 24778 → 24778×10−327.68 = 247,452.32 mA

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Purge cut vacuum switching valve duty CT200H_PURGE_CUT_VSV_DUTYConfirmed

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

0x0000 = 0 → 0×254096 = 0 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Racing operation CT200H_RACING_OPERATIONConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 90 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Regulator pressure CT200H_REGULATOR_PConfirmed

  • Service 21PID 53
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×37510525500−456.68
Range
-456.68 to 3294 kPa
Unit
kPa

0x3A = 58 → 58×37510525500−456.68 = 396.5 kPa

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Request engine run time CT200H_REQ_ENG_RUN_TIMEConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

0xFF = 255 → 25510 = 25.5 s

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Request warm-up CT200H_REQ_WARM_UPConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 89 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Requested engine torque CT200H_REQ_ENG_TQConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383
Unit
Number

0x0000 = 0 → 04 = 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Rough idle, cylinder 1 CT200H_ROUGH_IDLE_CYL_1

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Rough idle, cylinder 2 CT200H_ROUGH_IDLE_CYL_2

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Rough idle, cylinder 3 CT200H_ROUGH_IDLE_CYL_3

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Rough idle, cylinder 4 CT200H_ROUGH_IDLE_CYL_4

  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

SET/COAST switch CT200H_SET_COAST_SWITCHConfirmed

  • Service 21PID 21
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 36 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Short circuit wave highest value CT200H_SHORT_CIRCUIT_WAVEConfirmed

  • Service 21PID 9B
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×834250
Range
0 to 4.9799 V
Unit
V

0xC0 = 192 → 192×834250 = 3.749647 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Short FT B1S1 CT200H_SHORT_FT_B1S1Confirmed

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.218 %
Unit
%

0x80 = 128 → 128×200256−100 = 0 %

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2011 to 2012, 2016.

Standby blower request status CT200H_STANDBY_BLOWER_REQConfirmed

  • Service 21PID 9B
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Starter relay on CT200H_STARTER_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Stroke open CT200H_STROKE_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Synchronize stroke sensor position CT200H_SYNCHRONIZE_STROKE

  • Service 22DID 1634
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×25665535
Range
0 to 256 mm
Unit
mm

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

System guard on CT200H_SYSTEM_GUARD_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bit 144 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Throttle fully close learn CT200H_THROTTLE_FULLY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 112 to 119 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Throttle idle position on CT200H_THROTTLE_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bit 149 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Throttle motor current CT200H_THROTTLE_MOTOR

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 136 to 143 of the reply, 8 bits.

Formula
val×564
Range
0 to 19.9 A
Unit
A

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Throttle motor duty CT200H_THROTTLE_MOTOR_DUTYConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 136 to 143 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x29 = 41 → 41×100255 = 16.078431 %

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Throttle motor duty, close CT200H_THROTTLE_MOTOR_DUTY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Throttle motor duty, open CT200H_THROTTLE_MOTOR_DUTY_OPEN

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Throttle position CT200H_THROTTLE_21

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Throttle position CT200H_THROTTLE_POSConfirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 88 to 95 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

0x28 = 40 → 40×2051 = 15.686275 %

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Throttle position command CT200H_THROTTLE_POS_COMMANDConfirmed

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 32 to 39 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Throttle position, number 1 CT200H_THROTTLE_POS_NUMBER_1Confirmed

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 88 to 95 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Throttle position, number 2 CT200H_THROTTLE_POS_NUMBER_2Confirmed

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 96 to 103 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Throttle require position CT200H_THROTTLE_REQUIRE_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 104 to 111 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Throttle sensor open position 1 CT200H_THROTTLE_SENS_OPEN_1Confirmed

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Throttle sensor open position 2 CT200H_THROTTLE_SENS_OPEN_2Confirmed

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Throttle sensor position CT200H_THROTTLE_SENSOR_POSITIONConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 112 to 119 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Throttle sensor volt %, 1 CT200H_THROTTLE_SENSOR_VOLTConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x29 = 41 → 41×100255 = 16.078431 %

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Throttle sensor volt %, 2 CT200H_THROTTL_SENSOR_2_VOLTConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 128 to 135 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x7A = 122 → 122×100255 = 47.843137 %

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Time since DTCs cleared CT200H_TIME_AFTER_DTC_CLEAREDConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 168 to 183 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

0x1E25 = 7717 → 7,717 min

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Total fuel trim, bank 1 CT200H_TOT_FT_1Confirmed

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100256−50
Range
-50 to 49.6 %
Unit
%

0x80 = 128 → 128×100256−50 = 0 %

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Transmission fluid pan temperature CT200H_TF1_PAN

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1627
  • Module701 → 709
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.00703125−40
Range
-40 to 350 °F
Unit
°F

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Transmission fluid post-converter temperature CT200H_TF2_CONV

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1628
  • Module701 → 709
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.00703125−40
Range
-40 to 350 °F
Unit
°F

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Transmission fluid temperature CT200H_ATF_TEMP_700

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1638
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Transmission output shaft speed CT200H_TRANS_OUT_RPM

  • Service 21PID BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Turbine speed CT200H_SPD_NT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Valvematic current angle CT200H_VALVEMATIC_CURRENT

  • Service 21PID 31
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Valvematic, target angle CT200H_VALVEMATIC_TGT_ANGConfirmed

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

0x0000 = 0 → 0×5512 = 0 °

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Variable valve timing aim angle 1 CT200H_VARIABLE_VLV_TIM_AIM_1Confirmed

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333218450
Range
0 to 399 %
Unit
%

0x0000 = 0 → 0×1333218450 = 0 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Variable valve timing change angle 1 CT200H_VARIABLE_VLV_TIM_1Confirmed

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.0097642481
Range
0 to 639 °
Unit
°

0x0000 = 0 → 0×0.0097642481 = 0 °

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Variable valve timing control status 1 on CT200H_VARIABLE_VLV_TIM_1_ONConfirmed

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Variable valve timing oil control valve duty 1 CT200H_VARIABLE_VLV_TIM_OIL_1Confirmed

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0061020829
Range
0 to 399 %
Unit
%

0x0000 = 0 → 0×0.0061020829 = 0 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Variable valve timing oil temperature CT200H_VVTOT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Variable valve timing opening angle bank 1 CT200H_VVT_IE_OPENING_ANGLE_BANK_1

  • Service 22DID 2843
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Vehicle load CT200H_VEHICLE_LOADConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×10065535 = 0 %

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Vehicle speed CT200H_VSS_21

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Vehicle speed sensor test result, incomplete CT200H_SPD_TEST_RESULTConfirmed

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Warm-up cycles since DTCs cleared CT200H_WARMUP_CYCLE_CLEARED_DTCConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 152 to 159 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x0F = 15 → 15

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Water pump run control duty CT200H_WATER_PMP_RUN_CTRLConfirmed

  • Service 21PID 79
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×254
Range
0 to 1593 %
Unit
%

0x0A = 10 → 10×254 = 62.5 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Water pump running CT200H_WATER_PMP_RUNNINGConfirmed

  • Service 21PID 75
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Misfires

All cylinders misfire count CT200H_ALL_CYLINDERS_MISFIRE_CNTConfirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Cylinder #1 misfire count CT200H_CYL1_MISFIRE_CNTConfirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Cylinder #2 misfire count CT200H_CYL2_MISFIRE_CNTConfirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Cylinder #3 misfire count CT200H_CYL3_MISFIRE_CNTConfirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Cylinder #4 misfire count CT200H_CYL4_MISFIRE_CNTConfirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Misfire count, cylinder 1 CT200H_MIS_1

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Misfire count, cylinder 2 CT200H_MIS_2

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Misfire count, cylinder 3 CT200H_MIS_3

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Misfire count, cylinder 4 CT200H_MIS_4

  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Misfire load CT200H_MISFIRE_LOAD_7E0Confirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×4256
Range
0 to 3.98
Unit
Number

0x00 = 0 → 0×4256 = 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Misfire margin CT200H_MISFIRE_MARGIN_7E0Confirmed

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 80 to 87 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 %
Unit
%

0x1B = 27 → 27−128 = -101 %

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2011 to 2012, 2016.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2012, 2016. Supported for 2011.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2011 to 2012, 2016.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val8192
Range
0 to 7.999 V
Unit
V

Confirmed for 2012, 2016. Supported for 2011.

Fluids

Distance since oil change CT200H_OIL_CHANGE_ODOConfirmed

  • Service 21PID 41
  • Module7C0 → 7C8
  • Every30 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×251460015625
Range
0 to 41038.272 km
Unit
km

0x0F = 15 → 15×251460015625 = 2,414.016 km

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Fuel

Engine fuel rate CT200H_ENG_FUEL_RATE

  • Service 22DID F19D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel cut CT200H_FUEL_CUT

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Fuel cut CT200H_FUEL_CUT_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bit 121 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Fuel cut time CT200H_FUEL_CUT_TIME

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×537512
Range
0 to 68734.9511
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Fuel injection timing CT200H_FUEL_INJ_TIM

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Fuel level CT200H_FLI

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 1F2F
  • Module700 → 708
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Fuel level, volume CT200H_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 21PID 29
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5003785
Range
0 to 21 gal
Unit
gal

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Fuel pressure 1 CT200H_FUEL_P_1

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel pressure 1 CT200H_FUEL_P_1_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel pressure 2 CT200H_FUEL_P_2

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel pressure 2 CT200H_FUEL_P_2_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel pressure 3 CT200H_FUEL_P_3

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel pressure 3 CT200H_FUEL_P_3_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel pressure 4 CT200H_FUEL_P_4

  • Service 22DID 113C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 50000 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel pressure 4 CT200H_FUEL_P_4_700

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel pressure 5 CT200H_FUEL_P_5

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel pressure 6 CT200H_FUEL_P_6

  • Service 22DID 11C4
  • Module700 → 708
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×10
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel pump duty ratio CT200H_FUEL_PUMP_DUTY_RATIO

  • Service 22DID 106A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0609756098
Range
0 to 3996 kPa
Unit
kPa

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Fuel pump/speed status on CT200H_FUEL_PMP_SPD_STAT_ONConfirmed

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Fuel return temperature CT200H_FUEL_RETURN_T

  • Service 22DID 1141
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2011. Supported for 2012, 2016.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2011. Supported for 2012, 2016.

Fuel temperature 1 CT200H_FUEL_T_1

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel temperature 1 CT200H_FUEL_T_1_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel temperature 2 CT200H_FUEL_T_2

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel temperature 2 CT200H_FUEL_T_2_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel temperature 3 CT200H_FUEL_T_3

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel temperature 3 CT200H_FUEL_T_3_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel temperature 4 CT200H_FUEL_T_4

  • Service 22DID 113E
  • Module700 → 708
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel temperature 4 CT200H_FUEL_T_4_700

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel temperature 5 CT200H_FUEL_T_5

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Fuel temperature 6 CT200H_FUEL_T_6

  • Service 22DID 11C5
  • Module700 → 708
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

High fuel pressure, actual CT200H_HFP_ACTUAL

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

High fuel pressure, target CT200H_HFP_TARGET

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Low fuel pressure CT200H_LOW_FUEL_PRESSURE

  • Service 22DID 1F6D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Target air-fuel ratio CT200H_TARGET_AIR_FUEL_RATIOConfirmed

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Vehicle fuel rate CT200H_VEH_FUEL_RATE

  • Service 22DID F19D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Lights

Check engine SW CT200H_CHECK_ENGINE_LIGHTConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Hazard switch history CT200H_HAZARD_SWITCH_HISTORYConfirmed

  • Service 21PID BC
  • Module7B0 → 7B8
  • Every3600 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 2 of the reply.

Unit
Named states

0b1 = 1 → COMPLETE

States
Raw valueStateMeaning
0INCOMPLETEIncomplete
1COMPLETEComplete

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Oil pressure switch CT200H_EOP_LIGHTConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2011 Lexus CT 200h.

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011. In testing for 2013 to 2015, 2017 to 2022. Supported for 2012, 2016.

P-seatbelt buckle SW CT200H_P_SEATBELT_BUCKLE_LIGHTConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Rheostat CT200H_RHEOSTATConfirmed

Higher values are brighter

  • Service 21PID 68
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFF = 255 → 255

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Stop light CT200H_STOP_LIGHT_SWConfirmed

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Stop light CT200H_STOP_LIGHT_SWITCHConfirmed

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Stop light relay CT200H_STOP_LIGHT_RELAYConfirmed

  • Service 21PID 3C
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Tail cancel SW CT200H_TAIL_CANCEL_LIGHTConfirmed

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Movement

Accelerator fully close learn 1 CT200H_ACCEL_FULLY_CLOSE_1Confirmed

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

0x28 = 40 → 40×125256 = 19.53125 °

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Accelerator fully close learn 2 CT200H_ACCEL_FULLY_CLOSE_2Confirmed

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

0x2E = 46 → 46×125256 = 22.460938 °

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Accelerator idle position on CT200H_ACCEL_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Bit 148 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Supported for 2016.

Accelerator pedal position 1 CT200H_ACCEL_PEDAL_POS_1Confirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 96 to 103 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

0x29 = 41 → 41×2051 = 16.078431 %

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Accelerator pedal position 2 CT200H_ACCEL_PEDAL_POS_2Confirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 104 to 111 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

0x51 = 81 → 81×2051 = 31.764706 %

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Accelerator position CT200H_ACCEL_POSConfirmed

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 40 to 55 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

0x2879 = 10361 → 10361×254096 = 63.238525 %

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Accelerator sensor out, number 1 CT200H_ACCEL_SENS_OUT_1Confirmed

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 72 to 79 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

0x00 = 0 → 0×5256 = 0 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Accelerator sensor out, number 2 CT200H_ACCEL_SENS_OUT_2Confirmed

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 80 to 87 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

0x10 = 16 → 16×5256 = 0.3125 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Average engine speed of all cylinders CT200H_AV_RPM_ALL_CYLConfirmed

Pelican can show this parameter as the engine speed.

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Bits 64 to 79 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Compressor speed CT200H_COMP_SPDConfirmed

  • Service 21PID 49
  • Module7C4 → 7CC
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Compressor, target speed CT200H_COMP_TGT_SPDConfirmed

  • Service 21PID 4A
  • Module7C4 → 7CC
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

0x0000 = 0 → 0 rpm

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Cruise control speed CT200H_CRUISE_CTRL_SPD

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Engine speed CT200H_ENGINE_SPEEDConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Engine speed of cylinder 1 CT200H_RPM_CYL_1Confirmed

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Engine speed of cylinder 2 CT200H_RPM_CYL_2Confirmed

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Bits 16 to 31 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Engine speed of cylinder 3 CT200H_RPM_CYL_3Confirmed

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Engine speed of cylinder 4 CT200H_RPM_CYL_4Confirmed

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Bits 48 to 63 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Engine speed_7e2 CT200H_RPM_7E2Confirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 48 to 63 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Front left wheel acceleration CT200H_FL_WHEEL_ACCELERATIONConfirmed

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

0x00 = 0 → 0×1.56906 = 0 m/s²

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Front left wheel speed CT200H_TIRE_FL_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Front left wheel speed? CT200H_FL_WHEEL_SPEED_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Front right wheel acceleration CT200H_FR_WHEEL_ACCELERATIONConfirmed

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

0x00 = 0 → 0×1.56906 = 0 m/s²

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Front right wheel speed CT200H_TIRE_FR_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Front right wheel speed? CT200H_FR_WHEEL_SPEED_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

High voltage, target engine speed CT200H_HIGH_V_TGT_RPMConfirmed

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

0x00 = 0 → 0×25 = 0 rpm

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Intercooler water pump speed, raw count CT200H_IWP_SPEED

  • Service 22DID 1075
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Minimum engine speed CT200H_MIN_RPM

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

NC1 speed CT200H_NC1_SPD

  • Service 22DID 1614
  • Module701 → 709
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 10000 rpm
Unit
rpm

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

NO speed CT200H_NO_SPD

  • Service 22DID 1618
  • Module701 → 709
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 10000 rpm
Unit
rpm

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

NT speed CT200H_NT_SPD

  • Service 22DID 161A
  • Module701 → 709
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 10000 rpm
Unit
rpm

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Rear left wheel acceleration CT200H_RL_WHEEL_ACCELERATIONConfirmed

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

0x00 = 0 → 0×1.56906 = 0 m/s²

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Rear left wheel speed CT200H_TIRE_RL_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Rear left wheel speed? CT200H_RL_WHEEL_SPEED_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Rear right wheel acceleration CT200H_RR_WHEEL_ACCELERATIONConfirmed

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

0x00 = 0 → 0×1.56906 = 0 m/s²

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Rear right wheel speed CT200H_TIRE_RR_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Rear right wheel speed? CT200H_RR_WHEEL_SPEED_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Secondary speed CT200H_NSS_SPD

  • Service 22DID 1616
  • Module701 → 709
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 10000 rpm
Unit
rpm

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Speed CT200H_VSS_7C0Confirmed

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7C0 → 7C8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Vehicle speed CT200H_VEHICLE_SPEEDConfirmed

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x09 = 9 → 9 km/h

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Vehicle speed CT200H_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7B0 → 7B8
  • Every200 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.35
Range
0 to 323.85 km/h
Unit
km/h

0x00 = 0 → 0×1.35 = 0 km/h

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2011 to 2012. Supported for 2016.

Vehicle speed_7e2 CT200H_VSS_7E2Confirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x2D = 45 → 45 km/h

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2011 to 2012. Supported for 2016.

Orientation

Deceleration CT200H_DECELConfirmed

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Bits 0 to 7 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Deceleration 2 CT200H_DECEL_2Confirmed

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Bits 8 to 15 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Deceleration open CT200H_DECELERATION_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Lateral g CT200H_LAT_GConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.5 to 2.5 g
Unit
g

0x00 = 0 → 050 = 0 g

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Longitudinal g CT200H_LNG_GConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.5 to 2.5 g
Unit
g

0x00 = 0 → 050 = 0 g

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Yaw rate value, degrees/sec CT200H_YAW_RATEConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

0x80 = 128 → 128−128 = 0 °

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Yaw rate, error? CT200H_YAW_RATE_OPEN_ERRORConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Yaw rate, sensor 1 CT200H_YAW_1Confirmed

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

0x69 = 105 → 105−128 = -23

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Yaw rate, sensor 2 CT200H_YAW_2Confirmed

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

0x69 = 105 → 105−128 = -23

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Zero point of deceleration CT200H_ZP_DECConfirmed

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

0x00 = 0 → 050 = 0 g

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Zero point of deceleration 2 CT200H_ZP_DEC2Confirmed

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

0x00 = 0 → 050 = 0 g

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Zero point of yaw rate CT200H_ZERO_POINT_OF_YAW_RATEConfirmed

  • Service 21PID A1
  • Module7B0 → 7B8
  • Every3600 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

0x80 = 128 → 128−128 = 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Zero point of yaw rate, degrees/sec CT200H_ZP_YAWConfirmed

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

0x80 = 128 → 128−128 = 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Seatbelts

Buckle switch, left side CT200H_BUCKLE_LS

  • Service 21PID 04
  • Module780 → 788
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Supported for 2011 to 2012, 2016.

Buckle switch, right side CT200H_BUCKLE_RSConfirmed

  • Service 21PID 04
  • Module780 → 788
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x01 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Reverse beep CT200H_REVERSE_BEEPConfirmed

  • Service 21PID AC
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
On or off

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Seat belt beep, driver CT200H_SEAT_BELT_BEEP_DRIVERConfirmed

  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Seat belt beep, passenger CT200H_SEAT_BELT_BEEP_PASSENGERConfirmed

  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Seat belt beep, reminder CT200H_SEAT_BELT_BEEP_REMINDERConfirmed

  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Tires

Brake assist status CT200H_BA_CTRL_STATUSConfirmed

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Front left tire pressure CT200H_TP_FL_V1

Pelican can show this parameter as the front left tire pressure.

  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Front left tire temperature CT200H_TT_FL_V1

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 150 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Front left wheel ABS status CT200H_FL_WHEEL_ABS_CTRLConfirmed

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Front left wheel vehicle stability control status CT200H_FL_WHEEL_VSC_CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Front right tire pressure CT200H_TP_FR_V1

Pelican can show this parameter as the front right tire pressure.

  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Front right tire temperature CT200H_TT_FR_V1

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 150 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Front right wheel ABS status CT200H_FR_WHEEL_ABS_CTRLConfirmed

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Front right wheel cylinder open CT200H_FR_WHEEL_CYLINDER_OPENConfirmed

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Front right wheel vehicle stability control status CT200H_FR_WHEEL_VSC_CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Predictive brake assist status CT200H_PBA_CTRL_STATUSConfirmed

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Rear left tire pressure CT200H_TP_RL_V1

Pelican can show this parameter as the rear left tire pressure.

  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Rear left tire temperature CT200H_TT_RL_V1

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 150 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Rear left wheel ABS status CT200H_RL_WHEEL_ABS_CTRLConfirmed

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Rear left wheel EBS status CT200H_RL_WHEEL_EBD_CTRLConfirmed

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Rear left wheel vehicle stability control status CT200H_RL_WHEEL_VSC_CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Rear right tire pressure CT200H_TP_RR_V1

Pelican can show this parameter as the rear right tire pressure.

  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Rear right tire temperature CT200H_TT_RR_V1

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 150 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Rear right wheel ABS status CT200H_RR_WHEEL_ABS_CTRLConfirmed

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Rear right wheel EBS status CT200H_RR_WHEEL_EBD_CTRLConfirmed

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Rear right wheel vehicle stability control status CT200H_RR_WHEEL_VSC_CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Spare tire pressure CT200H_TP_SPARE_V1

  • Service 21PID 30
  • Module750 → 758
  • Every2.5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val58−0.5
Range
0 to 3.896 bar
Unit
bar

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Spare tire temperature CT200H_TT_SPARE_V1

  • Service 21PID 16
  • Module750 → 758
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val−40
Range
-40 to 150 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Tire 1 position CT200H_TID_1

  • Service 22DID 2021
  • Module750 → 758
  • Every86400 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1FLFront left
2FRFront right
3RLRear left
4RRRear right

In testing for 2012 to 2015. Not supported for 2011, 2016.

Tire 2 position CT200H_TID_2

  • Service 22DID 2021
  • Module750 → 758
  • Every86400 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1FLFront left
2FRFront right
3RLRear left
4RRRear right

In testing for 2012 to 2015. Not supported for 2011, 2016.

Tire 3 position CT200H_TID_3

  • Service 22DID 2021
  • Module750 → 758
  • Every86400 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1FLFront left
2FRFront right
3RLRear left
4RRRear right

In testing for 2012 to 2015. Not supported for 2011, 2016.

Tire 4 position CT200H_TID_4

  • Service 22DID 2021
  • Module750 → 758
  • Every86400 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1FLFront left
2FRFront right
3RLRear left
4RRRear right

In testing for 2012 to 2015. Not supported for 2011, 2016.

Tire pressure 1, set 2 CT200H_TIRE_P_1_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Tire pressure 2, set 2 CT200H_TIRE_P_2_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Tire pressure 3, set 2 CT200H_TIRE_P_3_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Tire pressure 4, set 2 CT200H_TIRE_P_4_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Tire pressure 5, set 2 CT200H_TIRE_P_5_SET_2

  • Service 21PID 15
  • Module750 → 758
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×694000−0.5
Range
-0.5 to 3.89 bar
Unit
bar

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Torque converter turbine wheel speed CT200H_TQ_CONV_TURBINE_WHL

  • Service 21PID DA
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12750
Range
0 to 6 rpm
Unit
rpm

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Traction control, engine status CT200H_TRC_TRAC__ENGINE_CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Traction control, status CT200H_TRC_TRAC__CTRLConfirmed

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Wheel cylinder pressure CT200H_WHEEL_CYLINDER_PRESSUREConfirmed

  • Service 21PID 07
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2013 to 2015, 2017 to 2022

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

Confirmed for 2011 to 2012, 2016. In testing for 2013 to 2015, 2017 to 2022.

Transmission

Boost converter temperature at ignition on CT200H_BOOST_CONV_T_AFTER_ONConfirmed

  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x37 = 55 → 55−40 = 15 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Boost converter temperature max CT200H_BOOST_CONV_T_MAXConfirmed

  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x41 = 65 → 65−40 = 25 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Boost converter temperature, lower CT200H_BOOST_CONV_T_LOConfirmed

  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x37 = 55 → 55−40 = 15 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Boost converter temperature, upper CT200H_BOOST_CONV_T_HIConfirmed

  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x37 = 55 → 55−40 = 15 °C

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Converter carrier frequency, 9.55khz=0,9.13khz=1,8.71khz=2,8.29khz=3,7.87khz=4,7.45khz=5,4.8khz=6 CT200H_CONV_CARRIER_9_0_9_1_8_2_8_3_7_4_7_5_4_6Confirmed

  • Service 21PID 7D
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Converter fail CT200H_CONV_FAILConfirmed

  • Service 21PID 79
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Converter gate status CT200H_CONV_GATE_STATConfirmed

  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Converter shutdown CT200H_CONV_SHUTDOWNConfirmed

  • Service 21PID 79
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Current gear CT200H_GEAR_V2

  • Service 21PID DA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Gear CT200H_GEAR

  • Service 21PID 85
  • Module7E0 → 7E8
  • Every400 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 20
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Gear CT200H_GEAR_700

  • Service 22DID 1621
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Lock up state CT200H_AT_LOCK_UP_STATE

  • Service 22DID 1620
  • Module700 → 708
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Prohibit DC/DC converter signal CT200H_PROHIBIT_DC_DC_CONVConfirmed

  • Service 21PID 75
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Shift sensor main CT200H_SHIFT_SENS_MAINConfirmed

  • Service 21PID 41
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 0 to 7 of the reply, 8 bits.

Formula
val×834250
Range
0 to 4.9799 V
Unit
V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Shift sensor select main CT200H_SHIFT_SENS_SELECTConfirmed

  • Service 21PID 41
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×834250
Range
0 to 4.9799 V
Unit
V

0xAD = 173 → 173×834250 = 3.378588 V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Shift sensor select sub CT200H_SHIFT_SENS_SELECT_SUBConfirmed

  • Service 21PID 41
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 24 to 31 of the reply, 8 bits.

Formula
val×834250
Range
0 to 4.9799 V
Unit
V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Shift sensor sub CT200H_SHIFT_SENS_SUBConfirmed

  • Service 21PID 41
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2011 to 2015, 2017 to 2022

Bits 8 to 15 of the reply, 8 bits.

Formula
val×834250
Range
0 to 4.9799 V
Unit
V

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Torque converter and TE1 on CT200H_TQ_CONV_TE1_ONConfirmed

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2011 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2022.

Torque converter lock-up CT200H_TQC_LOCKUP

Engages a clutch inside the torque converter to create a direct connection between the engine and transmission, reducing slippage and improving efficiency.

  • Service 21PID 85
  • Module7E0 → 7E8
  • Every400 ms
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Transmission fluid post-converter temperature, variant 3 CT200H_TRANS_FLUID_POST_T_3

  • Service 22DID 1628
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Transmission fluid temperature, pan var.3 CT200H_ATF_T_PAN_V3

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1627
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Transmission fluid temperature, variant 5 CT200H_ATF_T_V_5

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Transmission fluid temperature, variant 8 CT200H_ATF_T_V_8

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Transmission fluid temperature, variant 9 CT200H_ATF_T_V_9

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Transmission fluid temperature, variant 10 CT200H_ATF_T_V_10_7E1

  • Service 21PID 82
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Transmission fluid temperature, variant 11 CT200H_ATF_T_V_11

  • Service 21PID 82
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Transmission fluid temperature, variant 12 CT200H_ATF_T_V_12

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Transmission fluid temperature, variant 14 CT200H_ATF_T_V_14

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Transmission fluid temperature, variant 14 CT200H_ATF_T_V_14_7E1

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Transmission fluid temperature, variant 21 CT200H_ATF_T_V_21

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Transmission fluid temperature, variant 21 CT200H_ATF_T_V_21_7E1

  • Service 21PID D9
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Transmission oil pressure calibration, complete CT200H_TRANS_OIL_PRESS

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Transmission shift state ratio CT200H_TRANS_SHIFT_ST_RAT

  • Service 22DID 1622
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×533321845000
Range
0 to 15.999
Unit
Number

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Transmission shift state ratio CT200H_TRANS_SHIFT_ST_RAT_701

  • Service 22DID 1622
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×533321845000
Range
0 to 15.999
Unit
Number

In testing for 2012 to 2015, 2017 to 2022. Not supported for 2011, 2016.

Transmission temperature, pan CT200H_ATF_PAN_T

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Transmission temperature, torque converter CT200H_ATF_TQC_T

  • Service 21PID 82
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Trips

DTC clear run distance CT200H_DTC_CLEAR_RUN_DISTConfirmed

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing for 2012 to 2015, 2017 to 2022

Example reply from a 2016 Lexus CT 200h.

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0E85 = 3717 → 3,717 km

Confirmed for 2011, 2016. In testing for 2012 to 2015, 2017 to 2022.

Odometer CT200H_ENG_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 0103
  • Module700 → 708
  • Every30 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2011 to 2015, 2017 to 2022. Not supported for 2016.

Odometer CT200H_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 28
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Odometer CT200H_ODO_V5

Pelican can show this parameter as the odometer.

  • Service 22DID 0103
  • Module701 → 709
  • Every10 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Previous trip distance CT200H_PREV_TRIP_DST

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km
Unit
km

In testing for 2013 to 2015, 2017 to 2022. Not supported for 2011 to 2012, 2016.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.