Kia Stonic

Parameters

The Kia Stonic has 408 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Cluster voltage STONIC_CLUSTER_VOLTAGEConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 40 to 47 of the reply, 8 bits.

Formula
val12.8
Range
0 to 18 V
Unit
V

0xA3 = 163 → 16312.8 = 12.734375 V

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery temperature STONIC_12V_BAT_T

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2017 to 2026.

12V battery voltage STONIC_12V_BAT_V

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000+6
Range
0 to 71.53 V
Unit
V

In testing for 2017 to 2026.

Battery capacity, battery sensor STONIC_BAT_CAP_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2017 to 2026.

Battery charge flag, battery sensor STONIC_BAT_CHG_FLAG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Battery current STONIC_BAT_CURRENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2017 to 2026.

Battery current, battery sensor STONIC_BAT_CURRENT_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2017 to 2026.

Battery current, battery sensor STONIC_BAT_CURRENT_BATSENS_7E0

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 736 to 751 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val16
Range
-2048 to 2047.9375 A
Unit
A

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Battery current, battery sensor STONIC_BAT_CURRENT_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2017 to 2026.

Battery health aging flag, battery sensor STONIC_BAT_HEALTH_AGING

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Battery is in use to crank the engine flag, battery sensor STONIC_BAT_CRANK_ENG_FLAG

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Battery quiescent current flag, battery sensor STONIC_BAT_QUIESCENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Battery sensor invalid condition flag, battery sensor STONIC_BATSENS_INVALID_COND

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Battery state of charge, battery sensor STONIC_BAT_ST_CHG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Battery state of charge, battery sensor STONIC_BAT_ST_CHG_BATSENS_7E0

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 784 to 791 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Battery state of charge, battery sensor STONIC_BAT_ST_CHG_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2017 to 2026.

Battery state of function, battery sensor STONIC_BAT_ST_FUNCTION

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×12.75255
Range
0 to 12.75 V
Unit
V

In testing for 2017 to 2026.

Battery state of health, battery sensor STONIC_BAT_ST_HEALTH

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Battery state of health, battery sensor STONIC_BAT_ST_HEALTH_BATSENS

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2017 to 2026.

Battery temperature STONIC_BAT_T

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 °C
Unit
°C

In testing for 2017 to 2026.

Battery temperature, battery sensor STONIC_BAT_T_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2017 to 2026.

Battery temperature, battery sensor STONIC_BAT_T_BATSENS_7E0

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 768 to 783 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1953250000
Range
-255.9836 to 255.9758 °C
Unit
°C

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Battery temperature, battery sensor STONIC_BAT_T_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val2−40
Range
-40 to 32727 °C
Unit
°C

In testing for 2017 to 2026.

Battery voltage STONIC_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val×1010000+6
Range
0 to 71.535 V
Unit
V

In testing for 2017 to 2026.

Battery voltage, battery sensor STONIC_BAT_V_BATSENS

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×12.75255+6
Range
0 to 18.75 V
Unit
V

In testing for 2017 to 2026.

Battery voltage, battery sensor STONIC_BAT_V_BATSENS_7E0

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 752 to 767 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×3265535
Range
0 to 32 V
Unit
V

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Battery voltage, battery sensor STONIC_BAT_V_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000+6
Range
0 to 71.53 V
Unit
V

In testing for 2017 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2018. Supported for 2017, 2022.

Control module voltage after ignition, raw count STONIC_CONTROL_MODULE_VOLTAGE_AFTER_IGNITION

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Control module voltage, raw count STONIC_CONTROL_MODULE_VOLTAGE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Coolant temperature sensor voltage STONIC_COOLANT_T_SENSOR_VOLTAGE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0048828125
Range
0 to 319.9951 V
Unit
V

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Dual-clutch transmission control module voltage STONIC_DUAL_CLU_TRANS_CTRL_V

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val13.6
Range
0 to 18.75 V
Unit
V

In testing for 2017 to 2026.

Gasoline particulate filter charge state STONIC_GPF_CHG_ST

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Gasoline particulate filter inlet temperature sensor raw voltage STONIC_GPF_INLET_T_SENS_RAW_V

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2017 to 2026.

Gasoline particulate filter outlet temperature sensor raw voltage STONIC_GPF_OUTLET_T_SENS_V

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2017 to 2026.

Intake air temperature sensor voltage STONIC_IAT_SENSOR_VOLTAGE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0048828125
Range
0 to 319.9951 V
Unit
V

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Manifold pressure sensor voltage STONIC_MAP_SENSOR_VOLTAGE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0048828125
Range
0 to 319.9951 V
Unit
V

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Relative accelerator pedal position voltage STONIC_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val5
Range
-6553.6 to 6553.4 V
Unit
V

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Response error from battery sensor flag, battery sensor STONIC_RESPONSE_ERROR

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Throttle position sensor voltage #1 STONIC_THROTTLE_POS_V_1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Throttle position sensor voltage #2 STONIC_THROTTLE_POS_V_2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Waste gate voltage STONIC_WASTE_GATE_V

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val×0.000152588
Range
0 to 9.99 V
Unit
V

In testing for 2017 to 2026.

Climate

Interior temperature, passenger legs vent STONIC_HVAC_IAT_PASSENGER_LEGS_VENT

  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Interior temperature, passenger vent STONIC_HVAC_IAT_PASSENGER_VENT

  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2018. Supported for 2017, 2022.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2017, 2022.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018.

Brake booster pressure STONIC_BRAKE_BOOSTER_P

  • Service 22DID E013
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val25
Range
-1310 to 1310
Unit
Raw value

In testing for 2017 to 2026.

Brake pedal STONIC_BRAKE_PEDAL

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Brake pedal STONIC_BRAKE_PEDAL_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Brake pressure STONIC_BRAKE_P

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val86.7
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Relative accelerator pedal position STONIC_APP_REL_TCM

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Steering angle STONIC_STEER_ANGLE_V2

  • Service 21PID 01
  • Module7D4 → 7DC
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
val×10100
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Steering wheel angle STONIC_STEER_ANGLE

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2017 to 2018. Supported for 2022.

ECU

Commanded evaporative purge STONIC_COMMANDED_EVAPORATIVE_PURGE

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6093 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Intake camshaft position actual STONIC_INTAKE_CAMSHAFT_POSITION_ACTUAL

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255.9921 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Intake camshaft position commanded STONIC_INTAKE_CAMSHAFT_POSITION_COMMANDED

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Intake manifold absolute pressure STONIC_INTAKE_MANIFOLD_ABSOLUTE_PRESSURE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val256
Range
0 to 255.996 kPa
Unit
kPa

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Knock retard cylinder #1 STONIC_KNOCK_RETARD_CYLINDER_1

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Knock retard cylinder #2 STONIC_KNOCK_RETARD_CYLINDER_2

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Knock retard cylinder #3 STONIC_KNOCK_RETARD_CYLINDER_3

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Knock retard cylinder #4 STONIC_KNOCK_RETARD_CYLINDER_4

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Oxygen sensor 1 bank 1 STONIC_OXYGEN_SENSOR_11

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.1285 V
Unit
V

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Oxygen sensor 2 bank 1 STONIC_OXYGEN_SENSOR_21

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.1285 V
Unit
V

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Electrical

Cluster voltage STONIC_CLUSTER_VOLTAGEConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 40 to 47 of the reply, 8 bits.

Formula
val12.8
Range
0 to 18 V
Unit
V

0xA3 = 163 → 16312.8 = 12.734375 V

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Engine

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2018. Supported for 2017, 2022.

Air conditioning pressure STONIC_AC_P

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×13.79
Range
0 to 3516.45 kPa
Unit
kPa

In testing for 2017 to 2026.

Air conditioning relay STONIC_AC_RELAY

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 101 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Automatic transmission fluid temperature STONIC_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Automatic transmission fluid temperature STONIC_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2018. Supported for 2017, 2022.

Barometric pressure STONIC_BAROMETRIC_PRESSURE

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Boost pressure STONIC_BOOST_P

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2017 to 2026.

Boost pressure upstream STONIC_BOOST_P_UP

  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×39500
Range
0 to 5111
Unit
Raw value

In testing for 2017 to 2026.

Boost pressure upstream, desired STONIC_BOOST_P_UP_DES

  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×39500
Range
0 to 5111
Unit
Raw value

In testing for 2017 to 2026.

Butane in liquefied petroleum gas STONIC_BUTANE_LPG

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026. Not supported for 2017.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018. Supported for 2022.

Calculated oil temperature STONIC_CALC_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID E011
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Camshaft exhaust position, actual STONIC_CAM_EXH_POS_ACT

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×-38−40
Range
-135 to -40 °
Unit
°

In testing for 2017 to 2026.

Camshaft exhaust position, commanded STONIC_CAM_EXH_POS_CMD

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×-38−40
Range
-135 to -40 °
Unit
°

In testing for 2017 to 2026.

Camshaft intake position, actual STONIC_CAM_INT_POS_ACT

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×38+60
Range
0 to 155 °
Unit
°

In testing for 2017 to 2026.

Camshaft intake position, commanded STONIC_CAM_INT_POS_CMD

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×38+60
Range
0 to 155 °
Unit
°

In testing for 2017 to 2026.

Catalyst damaging misfires total all cylinders STONIC_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERSConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Catalyst damaging misfires total all cylinders STONIC_CATDMG_MIS_TOT_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 1 STONIC_CATALYST_DAMAGING_MISFIRES_TOTAL_C1Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Catalyst damaging misfires total, cylinder 1 STONIC_CATDMG_MIS_TOT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 2 STONIC_CATALYST_DAMAGING_MISFIRES_TOTAL_C2Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Catalyst damaging misfires total, cylinder 2 STONIC_CATDMG_MIS_TOT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 3 STONIC_CATALYST_DAMAGING_MISFIRES_TOTAL_C3Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Catalyst damaging misfires total, cylinder 3 STONIC_CATDMG_MIS_TOT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst damaging misfires total, cylinder 4 STONIC_CATALYST_DAMAGING_MISFIRES_TOTAL_C4Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Catalyst damaging misfires total, cylinder 4 STONIC_CATDMG_MIS_TOT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2018. Supported for 2017, 2022.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2017 to 2018. Supported for 2022.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018. Supported for 2017, 2022.

Commanded throttle actuator STONIC_COMMANDED_THROTTLE_ACTUATOR

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6093 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2018.

Coolant fan duty STONIC_COOLANT_FAN_PWM

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Coolant fan PWM STONIC_CLT_FAN_PWM

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×15.2110000
Range
0 to 99.67 %
Unit
%

In testing for 2017 to 2026.

Coolant temperature STONIC_HVAC_COOLANT_T

  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Coverage driven length STONIC_COVERAGE_DRIVEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 392 to 423 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Crankshaft torque STONIC_CRANK_TQ

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×600255
Range
0 to 600 N·m
Unit
N·m

In testing for 2017 to 2026.

Cylinder 1 injection time, 1st pulse STONIC_CYL_1_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 1 injection time, 2nd pulse STONIC_CYL_1_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 2 injection time, 1st pulse STONIC_CYL_2_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 2 injection time, 2nd pulse STONIC_CYL_2_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 3 injection time, 1st pulse STONIC_CYL_3_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 3 injection time, 2nd pulse STONIC_CYL_3_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 4 injection time, 1st pulse STONIC_CYL_4_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Cylinder 4 injection time, 2nd pulse STONIC_CYL_4_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Diesel particulate filter differential pressure STONIC_DPF_DIFF_P

  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val×431.373100−100
Range
-100 to 1000
Unit
Raw value

In testing for 2017 to 2026.

Diesel particulate filter regeneration count STONIC_DPF_REGEN_CNT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 440 to 447 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Diesel particulate filter regeneration state STONIC_DPF_REGEN_ST

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bit 431 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Diesel particulate filter regeneration state STONIC_DPF_REGENERATION_STATE

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Diesel particulate filter successful regeneration count STONIC_DPF_SUCCESSFUL_REGEN

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Direct injection time 1 STONIC_DI_TIME_1

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 2 STONIC_DI_TIME_2

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 3 STONIC_DI_TIME_3

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Direct injection time 4 STONIC_DI_TIME_4

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2017 to 2026.

Dual-clutch transmission clutch 1, pressure sensor a STONIC_DUAL_CLU_TRANS_CLU_1_P

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2017 to 2026.

Dual-clutch transmission clutch 2, pressure sensor b STONIC_DUAL_CLU_TRANS_CLU_2_P_B

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2017 to 2026.

Dual-clutch transmission fluid temperature 1 STONIC_DUAL_CLU_ATF_T_1

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Dual-clutch transmission fluid temperature 2 STONIC_DUAL_CLU_ATF_T_2

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Dual-clutch transmission line pressure, sensor c STONIC_DUAL_CLU_TRANS_LINE_P_C

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2017 to 2026.

Emission relevant misfires total all cylinders STONIC_EMIS_MIS_TOT_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total all cylinders STONIC_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERSConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Emission relevant misfires total, cylinder 1 STONIC_EMIS_MIS_TOT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 1 STONIC_EMISSION_RELEVANT_MISFIRES_TOTAL_C1Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Emission relevant misfires total, cylinder 2 STONIC_EMIS_MIS_TOT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 2 STONIC_EMISSION_RELEVANT_MISFIRES_TOTAL_C2Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Emission relevant misfires total, cylinder 3 STONIC_EMIS_MIS_TOT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 3 STONIC_EMISSION_RELEVANT_MISFIRES_TOTAL_C3Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Emission relevant misfires total, cylinder 4 STONIC_EMIS_MIS_TOT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Emission relevant misfires total, cylinder 4 STONIC_EMISSION_RELEVANT_MISFIRES_TOTAL_C4Confirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017 to 2018.

Engine coolant temperature STONIC_ENGINE_COOLANT_T

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Engine oil temperature STONIC_ENGINE_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Engine oil temperature STONIC_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 272 to 279 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

0x8B = 139 → 139×34−48 = 56.25 °C

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Engine oil temperature STONIC_EOT_7E0

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×0.7843−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2017 to 2026.

Engine oil temperature STONIC_EOT_V2

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID ED02
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val−4
Range
-4 to 251 °C
Unit
°C

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2018. Supported for 2017, 2022.

Engine RPM STONIC_ENGINE_RPM_TCM

Pelican can show this parameter as the engine speed.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Engine run time, total STONIC_ENG_RUN_TIME_TOT

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6
Range
0 to 393209.9999 min
Unit
min

In testing for 2017 to 2026.

Engine running time total STONIC_ENG_RUNNING_TIME_TOT

  • Service 22DID E00E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6
Range
0 to 393210 min
Unit
min

In testing for 2017 to 2026.

Engine, actual torque STONIC_ENG_ACT_TQ

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×2.3529
Range
0 to 599.9895 N·m
Unit
N·m

In testing for 2017 to 2026.

Exhaust cam oil control valve duty STONIC_OIL_CTRL_VLV_IMPULSE_WIDTH

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Exhaust camshaft position STONIC_EXH_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2017 to 2026.

Exhaust gas temperature STONIC_EXHAUST_GAS_T

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
val×4.709803922+99
Range
99 to 1300 °C
Unit
°C

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Exhaust gas temperature before gasoline particulate filter sensor 1 STONIC_EXH_GAS_T_BEFORE_GPF_1

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×12125
Range
0 to 6291 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust gas temperature before gasoline particulate filter sensor 2 STONIC_EXH_GAS_T_BEFORE_GPF_2

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×12125
Range
0 to 6291 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust gas volume flow STONIC_EXH_GAS_VOLUME_FLOW

  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×7844910000
Range
0 to 2000
Unit
Raw value

In testing for 2017 to 2026.

Exhaust temperature 1, upstream of oxidation catalyst STONIC_EXH_T_1_UP_OXICAT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2017 to 2026.

Exhaust temperature 2, upstream of DPF STONIC_EXH_T_2_UP_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2017 to 2026.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2018. Supported for 2017, 2022.

Gasoline direct injection time bank a, 1 STONIC_GDI_IT_A1Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Gasoline direct injection time bank a, 2 STONIC_GDI_IT_A2Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Gasoline direct injection time bank a, 3 STONIC_GDI_IT_A3Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Gasoline direct injection time bank a, 4 STONIC_GDI_IT_A4Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Gasoline direct injection time bank b, 1 STONIC_GDI_IT_B1Confirmed

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

0x0000 = 0 → 010 = 0 ms

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Gasoline direct injection time bank b, 2 STONIC_GDI_IT_B2

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017, 2019 to 2026. Supported for 2018.

Gasoline direct injection time bank b, 3 STONIC_GDI_IT_B3

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017, 2019 to 2026. Supported for 2018.

Gasoline direct injection time bank b, 4 STONIC_GDI_IT_B4

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2017, 2019 to 2026. Supported for 2018.

Idle control mode STONIC_IDLE_CONTROL_MODE

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Ignition retard due to knock control 1 STONIC_IGN_RETARD_KNOCK_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2018 to 2026. Not supported for 2017.

Ignition retard due to knock control 2 STONIC_IGN_RETARD_KNOCK_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2018 to 2026. Not supported for 2017.

Ignition retard due to knock control 3 STONIC_IGN_RETARD_KNOCK_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2018 to 2026. Not supported for 2017.

Ignition retard due to knock control 4 STONIC_IGN_RETARD_KNOCK_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2018 to 2026. Not supported for 2017.

Injection duration cylinder 1 STONIC_INJ_DUR_1Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2026

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53 ms
Unit
ms

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Injection duration cylinder 2 STONIC_INJ_DUR_2Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2026

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53 ms
Unit
ms

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Injection duration cylinder 3 STONIC_INJ_DUR_3Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2026

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53 ms
Unit
ms

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Injection duration cylinder 4 STONIC_INJ_DUR_4Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2026

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53 ms
Unit
ms

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Injection impulse 1, cylinder 1 STONIC_INJ_IMPULSE_1_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 1, cylinder 2 STONIC_INJ_IMPULSE_1_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 1, cylinder 3 STONIC_INJ_IMPULSE_1_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 1, cylinder 4 STONIC_INJ_IMPULSE_1_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 2, cylinder 1 STONIC_INJ_IMPULSE_2_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 2, cylinder 2 STONIC_INJ_IMPULSE_2_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 2, cylinder 3 STONIC_INJ_IMPULSE_2_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 2, cylinder 4 STONIC_INJ_IMPULSE_2_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 3, cylinder 1 STONIC_INJ_IMPULSE_3_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 3, cylinder 2 STONIC_INJ_IMPULSE_3_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 3, cylinder 3 STONIC_INJ_IMPULSE_3_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2017 to 2026.

Injection impulse 3, cylinder 4 STONIC_INJ_IMPULSE_3_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2017 to 2026.

Injector correction factor 1 STONIC_INJ_CORR_FACTOR_1

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2017 to 2026.

Injector correction factor 2 STONIC_INJ_CORR_FACTOR_2

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2017 to 2026.

Injector correction factor 3 STONIC_INJ_CORR_FACTOR_3

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2017 to 2026.

Injector correction factor 4 STONIC_INJ_CORR_FACTOR_4

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2017 to 2026.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018. Supported for 2017, 2022.

Intake air temperature STONIC_EITConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 264 to 271 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

0x70 = 112 → 112×34−48 = 36 °C

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Intake air temperature STONIC_INTAKE_AIR_T

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Intake cam oil control valve duty STONIC_OIL_CTRL_VLV_IMPULSE

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Intake camshaft position STONIC_INT_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2017 to 2026.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2018. Supported for 2017, 2022.

Inverter temperature STONIC_HVAC_INVERTER_T

  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Knock detected STONIC_KNOCK_DETECTED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Knock detected STONIC_KNOCK_DETECTED_7E0Confirmed

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Knock learn, cylinder 1 STONIC_KNOCK_LEARN_1Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 160 to 167 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Knock learn, cylinder 2 STONIC_KNOCK_LEARN_2Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 168 to 175 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Knock learn, cylinder 3 STONIC_KNOCK_LEARN_3Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 176 to 183 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Knock learn, cylinder 4 STONIC_KNOCK_LEARN_4Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 184 to 191 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Knock retard cylinder 1 STONIC_KNOCK_RETARD_CYL_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2018 to 2026. Not supported for 2017.

Knock retard cylinder 1, alternate STONIC_KNOCK_RETARD_1_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Knock retard cylinder 1, alternate STONIC_KNOCK_RETARD_CYL_1_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 2 STONIC_KNOCK_RETARD_CYL_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2018 to 2026. Not supported for 2017.

Knock retard cylinder 2, alternate STONIC_KNOCK_RETARD_2_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Knock retard cylinder 2, alternate STONIC_KNOCK_RETARD_CYL_2_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 3 STONIC_KNOCK_RETARD_CYL_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2018 to 2026. Not supported for 2017.

Knock retard cylinder 3, alternate STONIC_KNOCK_RETARD_3_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Knock retard cylinder 3, alternate STONIC_KNOCK_RETARD_CYL_3_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard cylinder 4 STONIC_KNOCK_RETARD_CYL_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2018 to 2026. Not supported for 2017.

Knock retard cylinder 4, alternate STONIC_KNOCK_RETARD_4_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Knock retard cylinder 4, alternate STONIC_KNOCK_RETARD_CYL_4_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2017 to 2026.

Knock retard, cylinder 1 STONIC_KNOCK_RETARD_1Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Knock retard, cylinder 2 STONIC_KNOCK_RETARD_2Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 104 to 111 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Knock retard, cylinder 3 STONIC_KNOCK_RETARD_3Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Knock retard, cylinder 4 STONIC_KNOCK_RETARD_4Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Liquefied petroleum gas low side temperature STONIC_LPG_LOW_SIDE_T

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2018 to 2026. Not supported for 2017.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018. Supported for 2017, 2022.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2018.

Main injection volume STONIC_MAIN_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.392156863
Range
0 to 100 L
Unit
L

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Mass air flow rate STONIC_MAF_RATE

  • Service 22DID E010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.

Formula
val×0.04239
Range
0 to 10.8
Unit
Raw value

In testing for 2017 to 2026.

Misfires current total STONIC_MIS_CURRENT_TOT

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 584 to 591 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 1 STONIC_MIS_CURRENT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 536 to 543 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 2 STONIC_MIS_CURRENT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 544 to 551 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 3 STONIC_MIS_CURRENT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 552 to 559 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires current, cylinder 4 STONIC_MIS_CURRENT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 560 to 567 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Misfires harmful for catalyst, cylinder 1 STONIC_MIS_HARMFUL_CAT_1

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires harmful for catalyst, cylinder 2 STONIC_MIS_HARMFUL_CAT_2

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires harmful for catalyst, cylinder 3 STONIC_MIS_HARMFUL_CAT_3

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires harmful for catalyst, cylinder 4 STONIC_MIS_HARMFUL_CAT_4

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, current, cylinder 1 STONIC_MISFIRES_C1_CURConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Misfires, current, cylinder 2 STONIC_MISFIRES_C2_CURConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Misfires, current, cylinder 3 STONIC_MISFIRES_C3_CURConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Misfires, current, cylinder 4 STONIC_MISFIRES_C4_CURConfirmed

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Misfires, cylinder 1 STONIC_MIS_1_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, cylinder 2 STONIC_MIS_2_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, cylinder 3 STONIC_MIS_3_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Misfires, cylinder 4 STONIC_MIS_4_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2026.

Motor-driven power steering current STONIC_MDPS_MOTOR_CURRENTConfirmed

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 A
Unit
A

0x03 = 3 → 3 A

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Oil pump PWM STONIC_OIL_PMP_PWM

  • Service 22DID ED13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 71 of the reply.

Formula
val×2051
Range
0 to 0.392
Unit
Off or on

In testing for 2017 to 2026.

Output speed STONIC_OUTPUT_SPEED

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Overheat protection, active STONIC_OVERHEAT_PROTECTION

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 132 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2026.

Pilot injection volume STONIC_PILOT_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Post injection volume STONIC_POST_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Requested torque STONIC_REQUESTED_TORQUE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val×0.001526
Range
0 to 100.0064 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Requested torque limitation from traction control STONIC_REQ_TQ_LIM_TRACTION

  • Service 22DID ED06
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2017 to 2018. Supported for 2022.

Throttle position #1 STONIC_THROTTLE_POS_1

Pelican can show this parameter as the throttle position.

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Throttle position #2 STONIC_THROTTLE_POS_2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2018. Supported for 2017, 2022.

Timing advance #1 STONIC_TIMING_ADVANCE_1

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Timing advance #2 STONIC_TIMING_ADVANCE_2

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Timing advance #3 STONIC_TIMING_ADVANCE_3

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Timing advance #4 STONIC_TIMING_ADVANCE_4

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Torque converter slip STONIC_TORQUE_CONVERTER_SLIP

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Torque converter slip STONIC_TORQUE_CONVERTER_SLIP_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Torque converter slip STONIC_TQ_CONV_SLIP

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Torque, actual STONIC_TQ_ACT

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6140000
Range
0 to 99.94 %
Unit
%

In testing for 2017 to 2026.

Total sulfur mass STONIC_TOT_SULFUR_MASS

  • Service 22DID ED29
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000
Range
0 to 9999
Unit
Raw value

In testing for 2017 to 2026.

Transmission fluid temperature STONIC_ATF_T_7E0

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2026.

Turbine speed STONIC_TURBINE_SPEED

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Turbo boost pressure STONIC_TURBO_BOOST_P_7E0

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×0.008291
Range
0 to 543
Unit
Number

In testing for 2017 to 2026.

Turbo boost pressure, gauge STONIC_TURBO_BOOST

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val831.556909−12
Range
-10 to 66.81 psi
Unit
psi

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2018.

Variable valve timing temperature STONIC_CVVT_T

Continuously variable valve timing temperature.

  • Service 21PID 18
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val−48
Range
-48 to 207 °C
Unit
°C

In testing for 2017 to 2026.

Waste gate duty STONIC_WASTE_GATE_DUTY

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val×0.00305176
Range
0 to 199 %
Unit
%

In testing for 2017 to 2026.

Waste gate duty STONIC_WG_DUTY

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val×20065535
Range
0 to 200 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Waste gate position STONIC_WASTE_GATE_POS

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2017 to 2026.

Waste gate position STONIC_WG_POSITION

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 424 to 439 of the reply, 16 bits. The value is signed.

Formula
val×40065535
Range
-200 to 199.99 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Waste gate set point STONIC_WG_SETPOINT

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 440 to 455 of the reply, 16 bits. The value is signed.

Formula
val×40065535
Range
-200 to 100 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Waste gate target STONIC_WASTE_GATE_TGT

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2017 to 2026.

Waste gate voltage STONIC_WG_VOLTAGE

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val×1065535
Range
0 to 10 V
Unit
V

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Wide open throttle STONIC_WIDE_OPEN_THROTTLEConfirmed

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x12 = 18 → 18

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Misfires

Emission-relevant misfires, cylinder #1 STONIC_MIS_CNT_EMIS_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Emission-relevant misfires, cylinder #2 STONIC_MIS_CNT_EMIS_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Emission-relevant misfires, cylinder #3 STONIC_MIS_CNT_EMIS_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Emission-relevant misfires, cylinder #4 STONIC_MIS_CNT_EMIS_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires harmful for catalyst cylinder 1 STONIC_MIS_CAT_1

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires harmful for catalyst cylinder 2 STONIC_MIS_CAT_2

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires harmful for catalyst cylinder 3 STONIC_MIS_CAT_3

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires harmful for catalyst cylinder 4 STONIC_MIS_CAT_4

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires total counter, all cylinders STONIC_MIS_CNT_ALL

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires total counter, cylinder #1 STONIC_MIS_CNT_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires total counter, cylinder #2 STONIC_MIS_CNT_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires total counter, cylinder #3 STONIC_MIS_CNT_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires total counter, cylinder #4 STONIC_MIS_CNT_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires, cylinder 1 STONIC_MIS_1

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires, cylinder 2 STONIC_MIS_2

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires, cylinder 3 STONIC_MIS_3

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Misfires, cylinder 4 STONIC_MIS_4

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2017 to 2018.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2017 to 2018.

Unknown

Engine status byte STONIC_E004_BYTE0Confirmed

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Fuel

Cycle fuel consumption STONIC_CYCLE_FUEL_CONS

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 423 of the reply, 8 bits.

Formula
val×8.478100
Range
0 to 21.6189
Unit
Raw value

In testing for 2017 to 2026.

Fuel consumption since last DPF regeneration STONIC_FUEL_CONS_SINCE_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 432 to 439 of the reply, 8 bits.

Formula
val×1.2549
Range
0 to 319 L
Unit
L

In testing for 2017 to 2026.

Fuel cut STONIC_FUEL_CUT

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Fuel cut STONIC_FUEL_CUT_7E0Confirmed

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x17 = 23 → 23

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Fuel injection timing #1 STONIC_FUEL_INJECTION_TIMING_1

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Fuel injection timing #2 STONIC_FUEL_INJECTION_TIMING_2

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Fuel injection timing #3 STONIC_FUEL_INJECTION_TIMING_3

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Fuel injection timing #4 STONIC_FUEL_INJECTION_TIMING_4

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Fuel level input STONIC_FLI_INPUT

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 L
Unit
L

In testing for 2017 to 2026.

Fuel level, volume STONIC_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 L
Unit
L

0x10 = 16 → 162 = 8 L

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Fuel pressure STONIC_FUEL_P

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2017 to 2026.

Fuel pressure deviation STONIC_FUEL_P_DEV

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5306710000
Range
-173889.9456 to 173884.6389
Unit
Raw value

In testing for 2017 to 2026.

Fuel pressure set point STONIC_FUEL_P_SET_POINT

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2017 to 2026.

Fuel pressure set point deviation STONIC_FUEL_P_SET_POINT_DEV

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5306610000
Range
-173886.6688 to 173881.3622
Unit
Raw value

In testing for 2017 to 2026.

Fuel pressure, actual STONIC_FUEL_P_ACT

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2017 to 2026.

Fuel pressure, set point STONIC_FUEL_P_SET_POINT_7E0

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2017 to 2026.

Fuel rail low pressure STONIC_FUEL_RAIL_LOW_P

  • Service 22DID E006
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 2017 to 2026.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018.

Fuel temperature STONIC_FUEL_T

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val×0.7843−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2017 to 2026.

Liquefied petroleum gas electrical fuel pump PWM STONIC_LPG_ELECTRICAL_FUEL

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2018 to 2026. Not supported for 2017.

Liquefied petroleum gas pressure in fuel rail, average STONIC_LPG_P_FUEL_RAIL_AVG

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val2
Range
0 to 32767
Unit
Raw value

In testing for 2018 to 2026. Not supported for 2017.

Short term fuel % trim, bank 1 STONIC_STFT_B1

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0030517578−100
Range
0 to 99.9969 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Short term fuel % trim, bank 1 idle STONIC_STFT_B1_IDLE

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.046875
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Movement

Actual acceleration STONIC_ACT_ACCEL

  • Service 22DID ED04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×64255
Range
0 to 64 m/s²
Unit
m/s²

In testing for 2017 to 2026.

Commanded engine idle RPM STONIC_COMMANDED_ENGINE_IDLE_RPM

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 rpm
Unit
rpm

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Coolant fan high speed STONIC_COOLANT_FAN_HIGH_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Coolant fan high speed, 1.8 STONIC_COOLANT_FAN_HIGH_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 109 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Coolant fan low speed STONIC_COOLANT_FAN_LOW_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Coolant fan low speed, 1.8 STONIC_COOLANT_FAN_LOW_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 110 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Dual-clutch transmission engine RPM STONIC_DUAL_CLU_TRANS_RPM

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2017 to 2026.

Dual-clutch transmission vehicle speed STONIC_DUAL_CLU_TRANS_VSS

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2017 to 2026.

Engine coolant fan high speed, on/off STONIC_ENG_CLT_FAN_HIGH_SPD_OFF

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Engine coolant fan low speed STONIC_ENG_CLT_FAN_LOW_SPD

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Engine RPM STONIC_ENGINE_RPM

Pelican can show this parameter as the engine speed.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Engine RPM STONIC_RPM_7E1

Pelican can show this parameter as the engine speed.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Front left wheel speed STONIC_FL_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Front left wheel speed STONIC_TIRE_FL_VSS

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Front left wheel speed STONIC_TIRE_FL_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Front right wheel speed STONIC_FR_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Front right wheel speed STONIC_TIRE_FR_VSS

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Front right wheel speed STONIC_TIRE_FR_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Output speed STONIC_OUTPUT_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Output speed STONIC_OUTPUT_SPEED_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Rear left wheel speed STONIC_RL_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Rear left wheel speed STONIC_TIRE_RL_VSS

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Rear left wheel speed STONIC_TIRE_RL_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Rear right wheel speed STONIC_RR_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Rear right wheel speed STONIC_TIRE_RR_VSS

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Rear right wheel speed STONIC_TIRE_RR_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Relative accelerator pedal position STONIC_REL_APP

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Relative accelerator pedal position STONIC_RELATIVE_ACCELERATOR_PEDAL_POSITION

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6093 %
Unit
%

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Turbine speed STONIC_TURBINE_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2017 to 2026.

Turbine speed STONIC_TURBINE_SPEED_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Vehicle speed STONIC_VEHICLE_SPEED

Pelican can show this parameter as the speed.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Vehicle speed STONIC_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every500 ms
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 232 to 239 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x23 = 35 → 35 km/h

Confirmed for 2017 to 2018. In testing for 2019 to 2026.

Vehicle speed STONIC_VSS_7E1

Pelican can show this parameter as the speed.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2017 to 2018. Supported for 2022.

Vehicle speed, average STONIC_VSS_AVG

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Vehicle speed, v2 STONIC_VSS_V2

Pelican can show this parameter as the speed.

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×1.25
Range
0 to 318.75 km/h
Unit
km/h

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Vehicle traction control switch, raw STONIC_TC_SWITCH

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bit 150 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Tires

Front left wheel speed STONIC_FL_WHEEL_VSSConfirmed

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Front right wheel speed STONIC_FR_WHEEL_VSSConfirmed

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Rear left wheel speed STONIC_RL_WHEEL_VSSConfirmed

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Rear right wheel speed STONIC_RR_WHEEL_VSSConfirmed

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing for 2017, 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2018. In testing for 2017, 2019 to 2026.

Transmission

Commanded gear STONIC_COMMANDED_GEAR

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Commanded gear STONIC_COMMANDED_GEAR_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Current gear STONIC_CURRENT_GEAR

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Current gear STONIC_CURRENT_GEAR_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Current gear STONIC_CURRENT_GEAR_7E1_2

  • Service 21PID A1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Current gear STONIC_GEAR_CUR

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 188 to 191 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Dual-clutch transmission absolute pedal position d STONIC_DUAL_CLU_TRANS_ABS_D

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Dual-clutch transmission clutch 1 slip STONIC_DUAL_CLU_TRANS_CLU_1

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871 rpm
Unit
rpm

In testing for 2017 to 2026.

Dual-clutch transmission clutch 1 temperature STONIC_DUAL_CLU_TRANS_CLU_1_T

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 °C
Unit
°C

In testing for 2017 to 2026.

Dual-clutch transmission clutch 2 slip STONIC_DUAL_CLU_TRANS_CLU_2

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871 rpm
Unit
rpm

In testing for 2017 to 2026.

Dual-clutch transmission even shaft, gear engaged STONIC_DUAL_CLU_TRANS_EVEN

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Dual-clutch transmission gear ratio STONIC_DUAL_CLU_TRANS_GEAR

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2017 to 2026.

Dual-clutch transmission input shaft 1 STONIC_DUAL_CLU_TRANS_INPUT_1

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val2−16384
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2017 to 2026.

Dual-clutch transmission input shaft 2 STONIC_DUAL_CLU_TRANS_INPUT_2

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val2−16384
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2017 to 2026.

Dual-clutch transmission odd shaft, gear engaged STONIC_DUAL_CLU_TRANS_ODD

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Dual-clutch transmission throttle position STONIC_DUAL_CLU_TRANS

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2017 to 2026.

Gear STONIC_GEAR_7E0

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2026.

Gear selector STONIC_GEAR

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Next gear STONIC_GEAR_NXT

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 196 to 199 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Transmission fluid temperature STONIC_ATF_TEMP

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 21A0
  • Module7E0 → 7E8
  • Every10 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×95−40
Range
0 to 255 °F
Unit
°F

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Trips

Diesel particulate filter distance since last regeneration STONIC_DPF_DIST_SINCE_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 360 to 391 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Diesel particulate filter odometer at last regeneration STONIC_DPF_ODO_LAST_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 328 to 359 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Distance since last DPF regeneration STONIC_DISTANCE_SINCE_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 424 to 455 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Distance since last gasoline particulate filter regeneration STONIC_DIST_SINCE_GPF_REGEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 360 to 391 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Odometer STONIC_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 456 to 487 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Odometer STONIC_ODO_7E0

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Odometer at last DPF regeneration STONIC_ODO_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2019 to 2026. Not supported for 2017 to 2018.

Odometer at last gasoline particulate filter regeneration STONIC_ODO_LAST_GPF_REGEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 328 to 359 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2017 to 2026.

Odometer, imperial STONIC_ODO_MIConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2018 Kia Stonic.

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 mi
Unit
mi

0x005604 = 22020 → 22,020 mi

Confirmed for 2018. In testing for 2019 to 2026. Supported for 2017.

Odometer, metric STONIC_ODO_KMConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2019 to 2026

Example reply from a 2017 Kia Stonic.

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x02A7F6 = 174070 → 174,070 km

Confirmed for 2017. In testing for 2019 to 2026. Supported for 2018.

Tire pressure monitor deflation odometer history 1 STONIC_TPMS_DEFLATION_ODO_1

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor deflation odometer history 2 STONIC_TPMS_DEFLATION_ODO_2

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor deflation odometer history 3 STONIC_TPMS_DEFLATION_ODO_3

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 160 to 191 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor deflation odometer history 4 STONIC_TPMS_DEFLATION_ODO_4

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 192 to 223 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor deflation odometer history 5 STONIC_TPMS_DEFLATION_ODO_5

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 224 to 255 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor deflation odometer history 6 STONIC_TPMS_DEFLATION_ODO_6

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 256 to 287 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor deflation odometer history 7 STONIC_TPMS_DEFLATION_ODO_7

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 288 to 319 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor deflation odometer history 8 STONIC_TPMS_DEFLATION_ODO_8

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 320 to 351 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor deflation odometer history 9 STONIC_TPMS_DEFLATION_ODO_9

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 352 to 383 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor latest deflation odometer STONIC_TPMS_LATEST

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor latest set odometer STONIC_TPMS_LATEST_SET_ODO

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 384 to 415 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor set odometer history 1 STONIC_TPMS_SET_ODO_HISTORY_1

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 416 to 447 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor set odometer history 2 STONIC_TPMS_SET_ODO_HISTORY_2

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 448 to 479 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor set odometer history 3 STONIC_TPMS_SET_ODO_HISTORY_3

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 480 to 511 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor set odometer history 4 STONIC_TPMS_SET_ODO_HISTORY_4

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 512 to 543 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor set odometer history 5 STONIC_TPMS_SET_ODO_HISTORY_5

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 544 to 575 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor set odometer history 6 STONIC_TPMS_SET_ODO_HISTORY_6

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 576 to 607 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor set odometer history 7 STONIC_TPMS_SET_ODO_HISTORY_7

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 608 to 639 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor set odometer history 8 STONIC_TPMS_SET_ODO_HISTORY_8

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 640 to 671 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Tire pressure monitor set odometer history 9 STONIC_TPMS_SET_ODO_HISTORY_9

  • Service 22DID C104
  • Module7D1 → 7D9
  • Every15 s
  • Testing

Bits 672 to 703 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2017 to 2026.

Vehicle total distance STONIC_VEH_TOT_DIST

  • Service 21PID B3
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 248 to 287 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775 km
Unit
km

In testing for 2017 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.