Kia Cerato

Parameters

The Kia Cerato has 429 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Automatic transmission fluid temperature CERATO_ATF_T_7E1Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x82 = 130 → 130−40 = 90 °C

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12 v battery state of charge CERATO_AUX_SOC

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

12 v battery state of health CERATO_AUX_SOH

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 328 to 335 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

12V battery temperature CERATO_12V_BAT_T

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2003 to 2024.

12V battery voltage CERATO_12V_BAT_V

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000+6
Range
0 to 71.53 V
Unit
V

In testing for 2003 to 2024.

Battery capacity, battery sensor CERATO_BAT_CAP_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2003 to 2024.

Battery charge flag, battery sensor CERATO_BAT_CHG_FLAG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2024.

Battery current CERATO_BAT_CURRENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2003 to 2024.

Battery current, battery sensor CERATO_BAT_CURRENT_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2003 to 2024.

Battery current, battery sensor CERATO_BAT_CURRENT_BATSENS_7E0_7E0_06

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 736 to 751 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val16
Range
-2048 to 2047.9375 A
Unit
A

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Battery current, battery sensor CERATO_BAT_CURRENT_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2003 to 2024.

Battery health aging flag, battery sensor CERATO_BAT_HEALTH_AGING

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2024.

Battery is in use to crank the engine flag, battery sensor CERATO_BAT_CRANK_ENG_FLAG

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2024.

Battery quiescent current flag, battery sensor CERATO_BAT_QUIESCENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2024.

Battery sensor invalid condition flag, battery sensor CERATO_BATSENS_INVALID_COND

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2024.

Battery state of charge, battery sensor CERATO_BAT_ST_CHG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2024.

Battery state of charge, battery sensor CERATO_BAT_ST_CHG_BATSENS_7E0_7E0_06

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 784 to 791 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Battery state of charge, battery sensor CERATO_BAT_ST_CHG_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2003 to 2024.

Battery state of function, battery sensor CERATO_BAT_ST_FUNCTION

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×12.75255
Range
0 to 12.75 V
Unit
V

In testing for 2003 to 2024.

Battery state of health, battery sensor CERATO_BAT_ST_HEALTH

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2024.

Battery state of health, battery sensor CERATO_BAT_ST_HEALTH_BATSENS

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2003 to 2024.

Battery temperature CERATO_BAT_T

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 °C
Unit
°C

In testing for 2003 to 2024.

Battery temperature, battery sensor CERATO_BAT_T_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2003 to 2024.

Battery temperature, battery sensor CERATO_BAT_T_BATSENS_7E0_7E0_06

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 768 to 783 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1953250000
Range
-255.9836 to 255.9758 °C
Unit
°C

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Battery temperature, battery sensor CERATO_BAT_T_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val2−40
Range
-40 to 32727 °C
Unit
°C

In testing for 2003 to 2024.

Battery voltage CERATO_BAT_V

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val×1010000+6
Range
0 to 71.535 V
Unit
V

In testing for 2003 to 2024.

Battery voltage, battery sensor CERATO_BAT_V_BATSENS

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×12.75255+6
Range
0 to 18.75 V
Unit
V

In testing for 2003 to 2024.

Battery voltage, battery sensor CERATO_BAT_V_BATSENS_7E0_7E0_06

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 752 to 767 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×3265535
Range
0 to 32 V
Unit
V

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Battery voltage, battery sensor CERATO_BAT_V_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000+6
Range
0 to 71.53 V
Unit
V

In testing for 2003 to 2024.

Dual-clutch transmission control module voltage CERATO_DUAL_CLU_TRANS_CTRL_V

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val13.6
Range
0 to 18.75 V
Unit
V

In testing for 2003 to 2024.

Gasoline particulate filter charge state CERATO_GPF_CHG_ST

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Gasoline particulate filter inlet temperature sensor raw voltage CERATO_GPF_INLET_T_SENS_RAW_V

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2003 to 2024.

Gasoline particulate filter outlet temperature sensor raw voltage CERATO_GPF_OUTLET_T_SENS_V

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2003 to 2024.

Relative accelerator pedal position voltage CERATO_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val5
Range
-6553.6 to 6553.4 V
Unit
V

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Response error from battery sensor flag, battery sensor CERATO_RESPONSE_ERROR

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2024.

Throttle position sensor voltage #1 CERATO_THROTTLE_POSITION_SENSOR_VOLTAGE__1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Throttle position sensor voltage #2 CERATO_THROTTLE_POSITION_SENSOR_VOLTAGE__2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Waste gate voltage CERATO_WASTE_GATE_V

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val×0.000152588
Range
0 to 9.99 V
Unit
V

In testing for 2003 to 2024.

Wastegate position voltage CERATO_WASTEGATE_POS_V

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1.5310000
Range
-5.01 to 5.01 V
Unit
V

In testing for 2003 to 2024.

Climate

Defogging? CERATO_DEFOG_SWConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 62 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Heated steering wheel CERATO_HEATED_WHEEL

  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2024.

Heated steering wheel, alternate bit CERATO_HEATED_WHEEL_ALT

  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2024.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2020. Supported for 2017.

Control

Brake booster pressure CERATO_BRAKE_BOOSTER_P

  • Service 22DID E013
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val25
Range
-1310 to 1310
Unit
Raw value

In testing for 2003 to 2024.

Brake pedal CERATO_BRAKE_PEDALConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xF0 = 240 → 240

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Brake pressure CERATO_BRAKE_P

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val86.7
Range
0 to 100 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Brake pressure CERATO_BRAKE_P_V2

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val86.7
Range
0 to 100 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Brake switch CERATO_BRAKE_SW

  • Service 22DID B008
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bit 51 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2024.

Handbrake engaged? CERATO_HANDBRAKEConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 36 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Steering wheel angle CERATO_STEER_ANGLE

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Steering wheel angle CERATO_STEER_ANGLE_V2

  • Service 21PID 01
  • Module7D4 → 7DC
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Steering wheel angle CERATO_STEER_ANGLE_V2_7D1

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Doors

Front left door locked? CERATO_LOCK_FLConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 36 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Front left door open? CERATO_DOOR_FLConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Front right door locked? CERATO_LOCK_FRConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Front right door open? CERATO_DOOR_FRConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Hood latched? CERATO_HOODConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Rear left door open? CERATO_DOOR_RLConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 39 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Rear right door open? CERATO_DOOR_RRConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Trunk open? CERATO_TRUNKConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2020. Supported for 2017.

Electrical

Cluster voltage CERATO_CLUSTER_VOLTAGEConfirmed

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 40 to 47 of the reply, 8 bits.

Formula
val12.8
Range
0 to 18 V
Unit
V

0xA7 = 167 → 16712.8 = 13.046875 V

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Engine

Adaptation value for lower stop of wastegate actuator CERATO_ADPT_LO_STOP

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1.5310000
Range
-5.01 to 5.01 V
Unit
V

In testing for 2003 to 2024.

Air conditioning pressure CERATO_AC_P

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×3520255
Range
0 to 3520 kPa
Unit
kPa

In testing for 2003 to 2024.

Air conditioning relay CERATO_AC_RELAY

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 101 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2024.

Automatic transmission fluid temperature CERATO_ATF_T_7E1Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x82 = 130 → 130−40 = 90 °C

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Barometric pressure CERATO_BAROMETRIC_PRESSURE

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Boost pressure CERATO_BOOST_P

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2003 to 2024.

Boost pressure upstream CERATO_BOOST_P_UP

  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×39500
Range
0 to 5111
Unit
Raw value

In testing for 2003 to 2024.

Boost pressure upstream, desired CERATO_BOOST_P_UP_DES

  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×39500
Range
0 to 5111
Unit
Raw value

In testing for 2003 to 2024.

Butane in liquefied petroleum gas CERATO_BUTANE_LPG

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2024.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2020. Supported for 2017.

Calculated oil temperature CERATO_CALC_OIL_T

  • Service 22DID E011
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2024.

Camshaft exhaust position, actual CERATO_CAM_EXH_POS_ACT

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×-38−40
Range
-135 to -40 °
Unit
°

In testing for 2003 to 2024.

Camshaft exhaust position, commanded CERATO_CAM_EXH_POS_CMD

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×-38−40
Range
-135 to -40 °
Unit
°

In testing for 2003 to 2024.

Camshaft intake position, actual CERATO_CAM_INT_POS_ACT

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×38+60
Range
0 to 155 °
Unit
°

In testing for 2003 to 2024.

Camshaft intake position, commanded CERATO_CAM_INT_POS_CMD

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×38+60
Range
0 to 155 °
Unit
°

In testing for 2003 to 2024.

Catalyst damaging misfires all cylinders CERATO_CATDMG_MIS_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Catalyst damaging misfires total all cylinders CERATO_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Catalyst damaging misfires total, cylinder 1 CERATO_CATALYST_DAMAGING_MISFIRES_TOTAL_C1

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Catalyst damaging misfires total, cylinder 1 CERATO_CATDMG_MIS_TOT_1

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Catalyst damaging misfires total, cylinder 2 CERATO_CATALYST_DAMAGING_MISFIRES_TOTAL_C2

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Catalyst damaging misfires total, cylinder 2 CERATO_CATDMG_MIS_TOT_2

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Catalyst damaging misfires total, cylinder 3 CERATO_CATALYST_DAMAGING_MISFIRES_TOTAL_C3

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Catalyst damaging misfires total, cylinder 3 CERATO_CATDMG_MIS_TOT_3

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Catalyst damaging misfires total, cylinder 4 CERATO_CATALYST_DAMAGING_MISFIRES_TOTAL_C4

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Catalyst damaging misfires total, cylinder 4 CERATO_CATDMG_MIS_TOT_4

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Catalyst damaging misfires, cylinder 1 CERATO_CATDMG_MIS_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Catalyst damaging misfires, cylinder 2 CERATO_CATDMG_MIS_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Catalyst damaging misfires, cylinder 3 CERATO_CATDMG_MIS_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Catalyst damaging misfires, cylinder 4 CERATO_CATDMG_MIS_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Catalyst damaging misfires, cylinder 5 CERATO_CATDMG_MIS_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Catalyst damaging misfires, cylinder 6 CERATO_CATDMG_MIS_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2020. Supported for 2017.

Commanded evaporative purge CERATO_COMMANDED_EVAPORATIVE_PURGE

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Commanded throttle actuator CERATO_COMMANDED_THROTTLE_ACTUATOR

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Coolant CERATO_COOLANT_FAN

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Coolant fan PWM CERATO_CLT_FAN_PWM

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2024.

Coverage driven length CERATO_COVERAGE_DRIVEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 392 to 423 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2003 to 2024.

Crankshaft torque CERATO_CRANK_TQ

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×600255
Range
0 to 600 N·m
Unit
N·m

In testing for 2003 to 2024.

Cylinder 1 injection time, 1st pulse CERATO_CYL_1_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Cylinder 1 injection time, 2nd pulse CERATO_CYL_1_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Cylinder 2 injection time, 1st pulse CERATO_CYL_2_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Cylinder 2 injection time, 2nd pulse CERATO_CYL_2_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Cylinder 3 injection time, 1st pulse CERATO_CYL_3_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Cylinder 3 injection time, 2nd pulse CERATO_CYL_3_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Cylinder 4 injection time, 1st pulse CERATO_CYL_4_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Cylinder 4 injection time, 2nd pulse CERATO_CYL_4_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Diesel particulate filter differential pressure CERATO_DPF_DIFF_P

  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val×431.373100−100
Range
-100 to 1000
Unit
Raw value

In testing for 2003 to 2024.

Diesel particulate filter regeneration count CERATO_DPF_REGEN_CNT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 440 to 447 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Diesel particulate filter regeneration state CERATO_DPF_REGEN_ST

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bit 431 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2024.

Diesel particulate filter regeneration state CERATO_DPF_REGENERATION_STATE

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Diesel particulate filter successful regeneration count CERATO_DPF_SUCCESSFUL_REGEN

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Direct injection time 1 CERATO_DI_TIME_1

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 1st pulse, cylinder 1 CERATO_DI_TIME_1ST_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 1st pulse, cylinder 2 CERATO_DI_TIME_1ST_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 1st pulse, cylinder 3 CERATO_DI_TIME_1ST_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 1st pulse, cylinder 4 CERATO_DI_TIME_1ST_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 1st pulse, cylinder 5 CERATO_CYL5_INJ_TIME_1ST

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 1st pulse, cylinder 6 CERATO_CYL6_INJ_TIME_1ST

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 2 CERATO_DI_TIME_2

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 2nd pulse, cylinder 1 CERATO_DI_TIME_2ND_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 2nd pulse, cylinder 2 CERATO_DI_TIME_2ND_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 2nd pulse, cylinder 3 CERATO_DI_TIME_2ND_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 2nd pulse, cylinder 4 CERATO_DI_TIME_2ND_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 2nd pulse, cylinder 5 CERATO_CYL5_INJ_TIME_2ND

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 2nd pulse, cylinder 6 CERATO_CYL6_INJ_TIME_2ND

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 3 CERATO_DI_TIME_3

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 4 CERATO_DI_TIME_4

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 5 CERATO_DI_TIME_5

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2003 to 2024.

Direct injection time 6 CERATO_DI_TIME_6

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2003 to 2024.

Dual-clutch transmission clutch 1, pressure sensor a CERATO_DUAL_CLU_TRANS_CLU_1_P

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2003 to 2024.

Dual-clutch transmission clutch 2, pressure sensor b CERATO_DUAL_CLU_TRANS_CLU_2_P_B

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2003 to 2024.

Dual-clutch transmission fluid temperature 1 CERATO_DUAL_CLU_ATF_T_1

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2024.

Dual-clutch transmission fluid temperature 2 CERATO_DUAL_CLU_ATF_T_2

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2024.

Dual-clutch transmission line pressure, sensor c CERATO_DUAL_CLU_TRANS_LINE_P_C

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2003 to 2024.

Emission relevant misfires all cylinders CERATO_EMIS_MIS_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Emission relevant misfires total all cylinders CERATO_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Emission relevant misfires total, cylinder 1 CERATO_EMIS_MIS_TOT_1

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Emission relevant misfires total, cylinder 1 CERATO_EMISSION_RELEVANT_MISFIRES_TOTAL_C1

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Emission relevant misfires total, cylinder 2 CERATO_EMIS_MIS_TOT_2

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Emission relevant misfires total, cylinder 2 CERATO_EMISSION_RELEVANT_MISFIRES_TOTAL_C2

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Emission relevant misfires total, cylinder 3 CERATO_EMIS_MIS_TOT_3

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Emission relevant misfires total, cylinder 3 CERATO_EMISSION_RELEVANT_MISFIRES_TOTAL_C3

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Emission relevant misfires total, cylinder 4 CERATO_EMIS_MIS_TOT_4

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Emission relevant misfires total, cylinder 4 CERATO_EMISSION_RELEVANT_MISFIRES_TOTAL_C4

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Emission relevant misfires, cylinder 1 CERATO_EMIS_MIS_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Emission relevant misfires, cylinder 2 CERATO_EMIS_MIS_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Emission relevant misfires, cylinder 3 CERATO_EMIS_MIS_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Emission relevant misfires, cylinder 4 CERATO_EMIS_MIS_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Emission relevant misfires, cylinder 5 CERATO_EMIS_MIS_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Emission relevant misfires, cylinder 6 CERATO_EMIS_MIS_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2024.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020. Supported for 2017.

Engine oil temperature CERATO_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 272 to 279 of the reply, 8 bits.

Formula
val1.3333−48
Range
0 to 143.2547 °C
Unit
°C

0xBC = 188 → 1881.3333−48 = 93.003525 °C

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Engine oil temperature CERATO_EOT_7E0

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×0.7843−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2003 to 2024.

Engine oil temperature CERATO_EOT_V2

  • Service 22DID ED02
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val−4
Range
-4 to 251 °C
Unit
°C

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Engine run time, total CERATO_ENG_RUN_TIME_TOT

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6
Range
0 to 393209.9999 min
Unit
min

In testing for 2003 to 2024.

Engine running time total CERATO_ENG_RUNNING_TIME_TOT

  • Service 22DID E00E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6
Range
0 to 393210 min
Unit
min

In testing for 2003 to 2024.

Engine, actual torque CERATO_ENG_ACT_TQ

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×2.3529
Range
0 to 599.9895 N·m
Unit
N·m

In testing for 2003 to 2024.

Exhaust cam oil control valve duty CERATO_OIL_CTRL_VLV_IMPULSE_WIDTH

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2024.

Exhaust camshaft position CERATO_EXH_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2003 to 2024.

Exhaust gas temperature CERATO_EXHAUST_GAS_T

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
val×4.709803922+99
Range
99 to 1300 °C
Unit
°C

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Exhaust gas temperature before gasoline particulate filter sensor 1 CERATO_EXH_GAS_T_BEFORE_GPF_1

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×12125
Range
0 to 6291 °C
Unit
°C

In testing for 2003 to 2024.

Exhaust gas temperature before gasoline particulate filter sensor 2 CERATO_EXH_GAS_T_BEFORE_GPF_2

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×12125
Range
0 to 6291 °C
Unit
°C

In testing for 2003 to 2024.

Exhaust gas volume flow CERATO_EXH_GAS_VOLUME_FLOW

  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×7844910000
Range
0 to 2000
Unit
Raw value

In testing for 2003 to 2024.

Exhaust temperature 1, upstream of oxidation catalyst CERATO_EXH_T_1_UP_OXICAT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2003 to 2024.

Exhaust temperature 2, upstream of DPF CERATO_EXH_T_2_UP_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2003 to 2024.

Gasoline direct injection time bank a, 1 CERATO_GDI_IT_A1

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2003 to 2019, 2021 to 2024. Supported for 2020.

Gasoline direct injection time bank a, 2 CERATO_GDI_IT_A2

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2003 to 2019, 2021 to 2024. Supported for 2020.

Gasoline direct injection time bank a, 3 CERATO_GDI_IT_A3

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2003 to 2019, 2021 to 2024. Supported for 2020.

Gasoline direct injection time bank a, 4 CERATO_GDI_IT_A4

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2003 to 2019, 2021 to 2024. Supported for 2020.

Gasoline direct injection time bank b, 1 CERATO_GDI_IT_B1

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2003 to 2019, 2021 to 2024. Supported for 2020.

Gasoline direct injection time bank b, 2 CERATO_GDI_IT_B2

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2003 to 2019, 2021 to 2024. Supported for 2020.

Gasoline direct injection time bank b, 3 CERATO_GDI_IT_B3

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2003 to 2019, 2021 to 2024. Supported for 2020.

Gasoline direct injection time bank b, 4 CERATO_GDI_IT_B4

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2003 to 2019, 2021 to 2024. Supported for 2020.

Idle control mode CERATO_IDLE_CONTROL_MODE

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Ignition retard due to knock control 1 CERATO_IGN_RETARD_KNOCK_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2003 to 2024.

Ignition retard due to knock control 2 CERATO_IGN_RETARD_KNOCK_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2003 to 2024.

Ignition retard due to knock control 3 CERATO_IGN_RETARD_KNOCK_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2003 to 2024.

Ignition retard due to knock control 4 CERATO_IGN_RETARD_KNOCK_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2003 to 2024.

Injection duration cylinder 1 CERATO_INJ_DUR_1Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.6864 ms
Unit
ms

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Injection duration cylinder 2 CERATO_INJ_DUR_2Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.6864 ms
Unit
ms

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Injection duration cylinder 3 CERATO_INJ_DUR_3Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.6864 ms
Unit
ms

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Injection duration cylinder 4 CERATO_INJ_DUR_4Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53.6864 ms
Unit
ms

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Injector correction factor 1 CERATO_INJ_CORR_FACTOR_1

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2003 to 2024.

Injector correction factor 2 CERATO_INJ_CORR_FACTOR_2

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2003 to 2024.

Injector correction factor 3 CERATO_INJ_CORR_FACTOR_3

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2003 to 2024.

Injector correction factor 4 CERATO_INJ_CORR_FACTOR_4

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2003 to 2024.

Intake air temperature CERATO_IATConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 264 to 271 of the reply, 8 bits.

Formula
val1.3333−48
Range
0 to 143.2547 °C
Unit
°C

0x8A = 138 → 1381.3333−48 = 55.502588 °C

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Intake cam oil control valve duty CERATO_OIL_CTRL_VLV_IMPULSE

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2024.

Intake camshaft position CERATO_INT_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2003 to 2024.

Intake camshaft position actual CERATO_INTAKE_CAMSHAFT_POSITION_ACTUAL

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Intake camshaft position commanded CERATO_INTAKE_CAMSHAFT_POSITION_COMMANDED

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Knock detected CERATO_KNOCK_DETECTED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Knock learn cylinder 1 CERATO_KNOCK_LEARN_1

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 160 to 167 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Knock learn cylinder 2 CERATO_KNOCK_LEARN_2

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 168 to 175 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Knock learn cylinder 3 CERATO_KNOCK_LEARN_3

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 176 to 183 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Knock learn cylinder 4 CERATO_KNOCK_LEARN_4

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 184 to 191 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Knock retard cylinder #1 CERATO_KNOCK_RETARD_CYLINDER_1

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Knock retard cylinder #2 CERATO_KNOCK_RETARD_CYLINDER_2

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Knock retard cylinder #3 CERATO_KNOCK_RETARD_CYLINDER_3

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Knock retard cylinder #4 CERATO_KNOCK_RETARD_CYLINDER_4

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Knock retard cylinder 1 CERATO_KNOCK_RETARD_1Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

0xFF = -1 → -15 = -0.2 °

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Knock retard cylinder 1 CERATO_KNOCK_RETARD_CYL_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2003 to 2024.

Knock retard cylinder 1, alternate CERATO_KNOCK_RETARD_1_E019Confirmed

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

0xFF = 255 → 255×0.75−191.25 = 0 °

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Knock retard cylinder 1, alternate CERATO_KNOCK_RETARD_CYL_1_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2003 to 2024.

Knock retard cylinder 2 CERATO_KNOCK_RETARD_2Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 104 to 111 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Knock retard cylinder 2 CERATO_KNOCK_RETARD_CYL_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2003 to 2024.

Knock retard cylinder 2, alternate CERATO_KNOCK_RETARD_2_E019Confirmed

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

0xFF = 255 → 255×0.75−191.25 = 0 °

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Knock retard cylinder 2, alternate CERATO_KNOCK_RETARD_CYL_2_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2003 to 2024.

Knock retard cylinder 3 CERATO_KNOCK_RETARD_3Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Knock retard cylinder 3 CERATO_KNOCK_RETARD_CYL_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2003 to 2024.

Knock retard cylinder 3, alternate CERATO_KNOCK_RETARD_3_E019Confirmed

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

0xFF = 255 → 255×0.75−191.25 = 0 °

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Knock retard cylinder 3, alternate CERATO_KNOCK_RETARD_CYL_3_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2003 to 2024.

Knock retard cylinder 4 CERATO_KNOCK_RETARD_4Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25.6 to 25.4 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Knock retard cylinder 4 CERATO_KNOCK_RETARD_CYL_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2003 to 2024.

Knock retard cylinder 4, alternate CERATO_KNOCK_RETARD_4_E019Confirmed

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

0xFF = 255 → 255×0.75−191.25 = 0 °

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Knock retard cylinder 4, alternate CERATO_KNOCK_RETARD_CYL_4_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2003 to 2024.

Liquefied petroleum gas low side temperature CERATO_LPG_LOW_SIDE_T

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2003 to 2024.

Main injection volume CERATO_MAIN_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.392156863
Range
0 to 100 L
Unit
L

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Mass air flow rate CERATO_MAF_RATE

  • Service 22DID E010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.

Formula
val×0.04239
Range
0 to 10.8
Unit
Raw value

In testing for 2003 to 2024.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running CERATO_MAX_ADPT_LO_MECH_STOP_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2003 to 2024.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop CERATO_MAX_ADPT_LO_MECH_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2003 to 2024.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running CERATO_MIN_ADPT_LO_MECH_STOP_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2003 to 2024.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop CERATO_MIN_ADPT_LO_MECH_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2003 to 2024.

Misfire count #1 CERATO_MIS_1

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfire count #2 CERATO_MIS_2

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfire count #3 CERATO_MIS_3

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfire count #4 CERATO_MIS_4

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires current total CERATO_MIS_CURRENT_TOT

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 584 to 591 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Misfires current, cylinder 1 CERATO_MIS_CURRENT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 536 to 543 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Misfires current, cylinder 2 CERATO_MIS_CURRENT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 544 to 551 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Misfires current, cylinder 3 CERATO_MIS_CURRENT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 552 to 559 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Misfires current, cylinder 4 CERATO_MIS_CURRENT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 560 to 567 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Misfires current, cylinder 5 CERATO_MIS_CURRENT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 568 to 575 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Misfires current, cylinder 6 CERATO_MIS_CURRENT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 576 to 583 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Misfires, current, cylinder 1 CERATO_MISFIRES_C1_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Misfires, current, cylinder 2 CERATO_MISFIRES_C2_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Misfires, current, cylinder 3 CERATO_MISFIRES_C3_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Misfires, current, cylinder 4 CERATO_MISFIRES_C4_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Motor-driven power steering current CERATO_MDPS_MOTOR_CURRENTConfirmed

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 A
Unit
A

0x10 = 16 → 16 A

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Oil pump PWM CERATO_OIL_PMP_PWM

  • Service 22DID ED13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 71 of the reply.

Formula
val×2051
Range
0 to 0.392
Unit
Off or on

In testing for 2003 to 2024.

Oxygen sensor 1 bank 1 CERATO_OXYGEN_SENSOR_11

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.12 V
Unit
V

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Oxygen sensor 2 bank 1 CERATO_OXYGEN_SENSOR_21

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.12 V
Unit
V

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Parking sensor rear center left level CERATO_PARKING_SENS_REAR

  • Service 22DID B009
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Parking sensor rear center right level CERATO_PARKING_SENS_REAR_CENTER

  • Service 22DID B009
  • Module7A0 → 7A8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Pilot injection volume CERATO_PILOT_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Post injection volume CERATO_POST_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Requested torque CERATO_REQUESTED_TORQUE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val×0.001526
Range
0 to 100 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Requested torque limitation from traction control CERATO_REQ_TQ_LIM_TRACTION

  • Service 22DID ED06
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2024.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2020. Supported for 2017.

Throttle position #1 CERATO_THROTTLE_POSITION__1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Throttle position #2 CERATO_THROTTLE_POSITION__2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Timing advance #1 CERATO_TIMING_ADVANCE_1

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Timing advance #2 CERATO_TIMING_ADVANCE_2

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Timing advance #3 CERATO_TIMING_ADVANCE_3

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Timing advance #4 CERATO_TIMING_ADVANCE_4

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Torque converter slip CERATO_TORQUE_CONVERTER_SLIPConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

0x085B = 2139 → 21394−512 = 22.75 rpm

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Torque converter slip CERATO_TQ_CONV_SLIP

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2003 to 2024.

Torque, actual CERATO_TQ_ACT

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6140000
Range
0 to 99.94 %
Unit
%

In testing for 2003 to 2024.

Total sulfur mass CERATO_TOT_SULFUR_MASS

  • Service 22DID ED29
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000
Range
0 to 9999
Unit
Raw value

In testing for 2003 to 2024.

Transmission fluid temperature CERATO_ATF_T_7E0

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2024.

Turbo boost pressure CERATO_TURBO_BOOST_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×829.110000
Range
0 to 5433
Unit
Raw value

In testing for 2003 to 2024.

Turbo boost pressure CERATO_TURBO_BOOST_P_7E0

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×0.008291
Range
0 to 543
Unit
Number

In testing for 2003 to 2024.

Turbo boost pressure, gauge CERATO_TURBO_BOOSTConfirmed

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing for 2003 to 2019, 2021 to 2024

Bits 56 to 71 of the reply, 16 bits.

Formula
val831.556909−12
Range
-10 to 66.81 psi
Unit
psi

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Variable valve timing temperature CERATO_CVVT_T

Continuously variable valve timing temperature.

  • Service 21PID 18
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val−48
Range
-48 to 207 °C
Unit
°C

In testing for 2003 to 2024.

Waste gate duty CERATO_WASTE_GATE_DUTY

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val×0.00305176
Range
0 to 199 %
Unit
%

In testing for 2003 to 2024.

Waste gate duty CERATO_WG_DUTYConfirmed

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 408 to 423 of the reply, 16 bits.

Formula
val×20065535
Range
0 to 200 %
Unit
%

0x0000 = 0 → 0×20065535 = 0 %

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Waste gate position CERATO_WASTE_GATE_POS

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2003 to 2024.

Waste gate position CERATO_WG_POSITIONConfirmed

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 424 to 439 of the reply, 16 bits. The value is signed.

Formula
val×40065535
Range
-200 to 199.99 %
Unit
%

0x0000 = 0 → 0×40065535 = 0 %

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Waste gate set point CERATO_WG_SETPOINT

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing for 2003 to 2019, 2021 to 2024

Bits 440 to 455 of the reply, 16 bits. The value is signed.

Formula
val×40065535
Range
-200 to 100 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Waste gate target CERATO_WASTE_GATE_TGT

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2003 to 2024.

Waste gate voltage CERATO_WG_VOLTAGEConfirmed

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 392 to 407 of the reply, 16 bits.

Formula
val×1065535
Range
0 to 10 V
Unit
V

0x0000 = 0 → 0×1065535 = 0 V

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Wastegate control PWM, wastegate actuator CERATO_WASTEGATE_CTRL_PWM

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10032767
Range
-100 to 100 %
Unit
%

In testing for 2003 to 2024.

Wastegate position target, wastegate actuator CERATO_WASTEGATE_POS_TGT

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×20032767
Range
-200 to 200 %
Unit
%

In testing for 2003 to 2024.

Wastegate position, wastegate actuator CERATO_WASTEGATE_POS

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×20032767
Range
-200 to 200 %
Unit
%

In testing for 2003 to 2024.

Misfires

Emission-relevant misfires, cylinder #1 CERATO_MIS_CNT_EMIS_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Emission-relevant misfires, cylinder #2 CERATO_MIS_CNT_EMIS_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Emission-relevant misfires, cylinder #3 CERATO_MIS_CNT_EMIS_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Emission-relevant misfires, cylinder #4 CERATO_MIS_CNT_EMIS_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires harmful for catalyst cylinder 1 CERATO_MIS_CAT_1

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires harmful for catalyst cylinder 2 CERATO_MIS_CAT_2

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires harmful for catalyst cylinder 3 CERATO_MIS_CAT_3

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires harmful for catalyst cylinder 4 CERATO_MIS_CAT_4

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires total counter, all cylinders CERATO_MIS_CNT_ALL

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires total counter, cylinder #1 CERATO_MIS_CNT_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires total counter, cylinder #2 CERATO_MIS_CNT_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires total counter, cylinder #3 CERATO_MIS_CNT_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires total counter, cylinder #4 CERATO_MIS_CNT_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires, cylinder 1 CERATO_MIS_1_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires, cylinder 2 CERATO_MIS_2_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires, cylinder 3 CERATO_MIS_3_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Misfires, cylinder 4 CERATO_MIS_4_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2020.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2020.

Fuel

Fuel consumption since last DPF regeneration CERATO_FUEL_CONS_SINCE_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 432 to 439 of the reply, 8 bits.

Formula
val×1.2549
Range
0 to 319 L
Unit
L

In testing for 2003 to 2024.

Fuel cut CERATO_FUEL_CUT

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Fuel injection timing #1 CERATO_FUEL_INJECTION_TIMING_1

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Fuel injection timing #2 CERATO_FUEL_INJECTION_TIMING_2

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Fuel injection timing #3 CERATO_FUEL_INJECTION_TIMING_3

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Fuel injection timing #4 CERATO_FUEL_INJECTION_TIMING_4

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Fuel level input CERATO_FLI_INPUT

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 L
Unit
L

In testing for 2003 to 2024.

Fuel level, volume CERATO_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 L
Unit
L

0x3A = 58 → 582 = 29 L

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Fuel pressure CERATO_FUEL_P

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6110000
Range
0 to 399.7635
Unit
Raw value

In testing for 2003 to 2024.

Fuel pressure CERATO_FUEL_P_7E0

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2003 to 2024.

Fuel pressure deviation CERATO_FUEL_P_DEV

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5306710000
Range
-173889.9456 to 173884.6389
Unit
Raw value

In testing for 2003 to 2024.

Fuel pressure set point CERATO_FUEL_P_SET_POINT

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2003 to 2024.

Fuel pressure target CERATO_FUEL_P_TGT

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6110000
Range
0 to 399.7635
Unit
Raw value

In testing for 2003 to 2024.

Fuel rail low pressure CERATO_FUEL_RAIL_LOW_P

  • Service 22DID E006
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 2003 to 2024.

Fuel temperature CERATO_FUEL_T

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val×0.7843−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2003 to 2024.

Liquefied petroleum gas electrical fuel pump PWM CERATO_LPG_ELECTRICAL_FUEL

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2024.

Liquefied petroleum gas pressure in fuel rail, average CERATO_LPG_P_FUEL_RAIL_AVG

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val2
Range
0 to 32767
Unit
Raw value

In testing for 2003 to 2024.

Short term fuel % trim, bank 1 CERATO_STFT_B1

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0030517578−100
Range
0 to 99.99 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Short term fuel % trim, bank 1 idle CERATO_STFT_B1_IDLE

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.046875
Range
0 to 100 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Lights

Brake light CERATO_BRAKE_LIGHTConfirmed

  • Service 22DID BC06
  • Module770 → 778
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Defog light CERATO_DEFOG_LIGHTConfirmed

  • Service 22DID BC07
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Exterior lights state code CERATO_LIGHTS_CODE

  • Service 22DID BC10
  • Module770 → 778
  • Every5 s
  • Testing

Bits 32 to 35 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2003 to 2024.

Hazard switch CERATO_HAZARD_SWConfirmed

  • Service 22DID BC05
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Headlight high beam CERATO_HL_HIGHConfirmed

  • Service 22DID BC09
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 55 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Headlight low beam CERATO_HL_LOWConfirmed

  • Service 22DID BC09
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 63 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Headlight switch CERATO_HL_SW

  • Service 22DID BC05
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Left turn signal on? CERATO_TURN_LConfirmed

  • Service 22DID BC08
  • Module770 → 778
  • Every2 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 38 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Right turn signal on? CERATO_TURN_RConfirmed

  • Service 22DID BC08
  • Module770 → 778
  • Every2 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Movement

Actual acceleration CERATO_ACT_ACCEL

  • Service 22DID ED04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×64255
Range
0 to 64 m/s²
Unit
m/s²

In testing for 2003 to 2024.

Average wheel speed CERATO_VSS_AVG_V2

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Coolant fan high speed CERATO_COOLANT_FAN_HIGH_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Coolant fan high speed, 1.8 CERATO_COOLANT_FAN_HIGH_SPEED_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 109 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Coolant fan low speed CERATO_COOLANT_FAN_LOW_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Coolant fan low speed, 1.8 CERATO_COOLANT_FAN_LOW_SPEED_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 110 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Dual-clutch transmission engine RPM CERATO_DUAL_CLU_TRANS_RPM

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2003 to 2024.

Dual-clutch transmission vehicle speed CERATO_DUAL_CLU_TRANS_VSS

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2024.

Engine coolant fan high speed, on/off CERATO_ENG_CLT_FAN_HIGH_SPD_OFF

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Engine coolant fan low speed CERATO_ENG_CLT_FAN_LOW_SPD

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2003 to 2024.

Engine RPM CERATO_RPM_7E1Confirmed

Pelican can show this parameter as the engine speed.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0A48 = 2632 → 26324 = 658 rpm

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Front left wheel speed CERATO_TIRE_FL_VSS_V1

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Front left wheel speed CERATO_TIRE_FL_VSS_V2Confirmed

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Front left wheel speed CERATO_TIRE_FL_VSS_V2_7D1

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Front right wheel speed CERATO_TIRE_FR_VSS_V1

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Front right wheel speed CERATO_TIRE_FR_VSS_V2Confirmed

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Front right wheel speed CERATO_TIRE_FR_VSS_V2_7D1

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Output speed CERATO_OUTPUT_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2003 to 2024.

Output speed CERATO_OUTPUT_SPEEDConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 88 to 103 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Rear left wheel speed CERATO_TIRE_RL_VSS_V1

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Rear left wheel speed CERATO_TIRE_RL_VSS_V2Confirmed

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Rear left wheel speed CERATO_TIRE_RL_VSS_V2_7D1

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Rear right wheel speed CERATO_TIRE_RR_VSS_V1

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Rear right wheel speed CERATO_TIRE_RR_VSS_V2Confirmed

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Rear right wheel speed CERATO_TIRE_RR_VSS_V2_7D1

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Relative accelerator pedal position CERATO_REL_APPConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Relative accelerator pedal position CERATO_RELATIVE_ACCELERATOR_PEDAL_POSITION

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Traction control switch, raw CERATO_TC_SWITCH_V2

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every1 s
  • Testing

Bit 150 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Turbine speed CERATO_TURBINE_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2003 to 2024.

Turbine speed CERATO_TURBINE_SPEEDConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x09ED = 2541 → 25414 = 635.25 rpm

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Vehicle speed CERATO_VSS_7E1Confirmed

Pelican can show this parameter as the speed.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Vehicle speed CERATO_VSS_AVG

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Vehicle speed CERATO_VSS_V3

Pelican can show this parameter as the speed.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Vehicle speed, v2 CERATO_VSS_V2_7E0

Pelican can show this parameter as the speed.

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×1.25
Range
0 to 318.75 km/h
Unit
km/h

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Wheel traction control switch CERATO_TC_SWITCH

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bit 150 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2020. Supported for 2017.

Seatbelts

Driver seatbelt latched? CERATO_BELT_DRIVERConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Passenger seatbelt latched? CERATO_BELT_PASSENGERConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 45 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Rear left seatbelt latched? CERATO_BELT_RLConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Rear middle seatbelt latched? CERATO_BELT_RMConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 52 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Rear right seatbelt latched? CERATO_BELT_RRConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 54 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Tires

Front left tire pressure CERATO_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 32 to 39 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Front left tire reading invalid? CERATO_FL_INVALIDConfirmed

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 62 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Front left tire temperature CERATO_TT_FL

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 40 to 47 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Front left wheel speed CERATO_FL_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Front right tire pressure CERATO_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 64 to 71 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Front right tire reading invalid? CERATO_FR_INVALIDConfirmed

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 94 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Front right tire temperature CERATO_TT_FR

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Front right wheel speed CERATO_FR_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Rear left tire pressure CERATO_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 128 to 135 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Rear left tire reading invalid? CERATO_RL_INVALIDConfirmed

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 126 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Rear left tire temperature CERATO_TT_RL

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 136 to 143 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Rear left wheel speed CERATO_RL_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Rear right tire pressure CERATO_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 96 to 103 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Rear right tire reading invalid? CERATO_RR_INVALIDConfirmed

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 158 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b1 = 1 → 1

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Rear right tire temperature CERATO_TT_RR

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 104 to 111 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Rear right wheel speed CERATO_RR_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2019, 2021 to 2024. Not supported for 2020.

Tire sensor 1 ID CERATO_TID_1

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2003 to 2024.

Tire sensor 2 ID CERATO_TID_2

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2003 to 2024.

Tire sensor 3 ID CERATO_TID_3

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2003 to 2024.

Tire sensor 4 ID CERATO_TID_4

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2003 to 2024.

Transmission

Automatic transmission fluid temperature CERATO_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Clutch #1 temperature CERATO_CLUTCH_1_T

Part of the dual clutch transition

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val×2−40
Range
-40 to 300 °C
Unit
°C

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Clutch #2 temperature CERATO_CLUTCH_2_T

Part of the dual clutch transition

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val×2−40
Range
-40 to 300 °C
Unit
°C

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Commanded gear CERATO_COMMANDED_GEARConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Current gear CERATO_CURRENT_GEARConfirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Current gear CERATO_CURRENT_GEAR_7E1_2

  • Service 21PID A1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Current gear CERATO_GEAR

The automatic transmission gear.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1NEUTRALNeutral
2REVERSEReverse
3PARKPark
4MANUALManual

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Current gear CERATO_GEAR_CUR

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 188 to 191 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Dual-clutch transmission absolute pedal position d CERATO_DUAL_CLU_TRANS_ABS_D

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2024.

Dual-clutch transmission clutch 1 slip CERATO_DUAL_CLU_TRANS_CLU_1

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871 rpm
Unit
rpm

In testing for 2003 to 2024.

Dual-clutch transmission clutch 1 temperature CERATO_DUAL_CLU_TRANS_CLU_1_T

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 °C
Unit
°C

In testing for 2003 to 2024.

Dual-clutch transmission clutch 2 slip CERATO_DUAL_CLU_TRANS_CLU_2

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871 rpm
Unit
rpm

In testing for 2003 to 2024.

Dual-clutch transmission even shaft, gear engaged CERATO_DUAL_CLU_TRANS_EVEN

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Dual-clutch transmission gear ratio CERATO_DUAL_CLU_TRANS_GEAR

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2003 to 2024.

Dual-clutch transmission input shaft 1 CERATO_DUAL_CLU_TRANS_INPUT_1

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val2−16384
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2003 to 2024.

Dual-clutch transmission input shaft 2 CERATO_DUAL_CLU_TRANS_INPUT_2

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val2−16384
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2003 to 2024.

Dual-clutch transmission odd shaft, gear engaged CERATO_DUAL_CLU_TRANS_ODD

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Dual-clutch transmission throttle position CERATO_DUAL_CLU_TRANS

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2003 to 2024.

Gear CERATO_GEAR_7E0

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2024.

Gear selector CERATO_GEAR_7E1Confirmed

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x0B = 11 → 11

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Next gear CERATO_GEAR_NXT

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 196 to 199 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Reverse gear selected CERATO_REVERSE_GEARConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Transmission fluid temperature CERATO_ATF_TEMP

  • Service 22DID 21A0
  • Module7E0 → 7E8
  • Every10 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×95−40
Range
0 to 255 °F
Unit
°F

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Trips

Diesel particulate filter distance since last regeneration CERATO_DPF_DIST_SINCE_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 360 to 391 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2003 to 2024.

Diesel particulate filter odometer at last regeneration CERATO_DPF_ODO_LAST_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 328 to 359 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2003 to 2024.

Distance since last DPF regeneration CERATO_DISTANCE_SINCE_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 424 to 455 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Distance since last gasoline particulate filter regeneration CERATO_DIST_SINCE_GPF_REGEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 360 to 391 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2003 to 2024.

Odometer CERATO_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 456 to 487 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Odometer CERATO_ODO_7E0

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2003 to 2024.

Odometer at last DPF regeneration CERATO_ODO_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005, 2020.

Odometer at last gasoline particulate filter regeneration CERATO_ODO_LAST_GPF_REGEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 328 to 359 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2003 to 2024.

Odometer, imperial CERATO_ODO_MI

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 mi
Unit
mi

In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Supported for 2020. Not supported for 2005.

Odometer, metric CERATO_ODO_KMConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2003 to 2019, 2021 to 2024

Example reply from a 2020 Kia Cerato.

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x0062A6 = 25254 → 25,254 km

Confirmed for 2020. In testing for 2003 to 2004, 2006 to 2019, 2021 to 2024. Not supported for 2005.

Sensor #1 odometer event #1 CERATO_SENS_1_ODO_EVT_1

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2003 to 2024.

Sensor #1 odometer event #2 CERATO_SENS_1_ODO_EVT_2

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2003 to 2024.

Sensor #1 odometer event #3 CERATO_SENS_1_ODO_EVT_3

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2003 to 2024.

Sensor #2 odometer event #1 CERATO_SENS_2_ODO_EVT_1

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2003 to 2024.

Sensor #2 odometer event #2 CERATO_SENS_2_ODO_EVT_2

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2003 to 2024.

Sensor #2 odometer event #3 CERATO_SENS_2_ODO_EVT_3

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2003 to 2024.

Sensor #3 odometer event #1 CERATO_SENS_3_ODO_EVT_1

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2003 to 2024.

Sensor #3 odometer event #2 CERATO_SENS_3_ODO_EVT_2

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2003 to 2024.

Sensor #3 odometer event #3 CERATO_SENS_3_ODO_EVT_3

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2003 to 2024.

Sensor #4 odometer event #1 CERATO_SENS_4_ODO_EVT_1

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2003 to 2024.

Sensor #4 odometer event #2 CERATO_SENS_4_ODO_EVT_2

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2003 to 2024.

Sensor #4 odometer event #3 CERATO_SENS_4_ODO_EVT_3

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2003 to 2024.

Vehicle total distance CERATO_VEH_TOT_DIST

  • Service 21PID B3
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 248 to 287 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775 km
Unit
km

In testing for 2003 to 2024.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.